| Installation Manual of Room Air Conditioner   Preparation   Necessary Tools for Installation   Selection of Installation Place   ● Torque wrench   (17mm,22mm,26mm)   ● Driver   ● Nipper   ● Hacksaw   Indoor Unit   ● Place, robust not causing vibration, where the body can be supported sufficiently.   ● Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the   unit are not disturbed.   ● Place, possible to drain easily, where piping can be connected with the outdoor unit.   ● Place, where cold air can be spread in a room entirely.   ● Place, nearby a power receptacle, with enough space around. (Refer to drawings).   ● Pipe cutter   ● Flaring tool   ● Knife   ● Measuring tape   ● Reamer   ● Hole core drill   ● Spanner(17,19 and 26mm)   ● Gas leakage detector or   soap-and-water solution   ● Place where the distance of more than lm from televisions, radios, wireless apparatuses   and fluorescent lamps can be left.   ● In the case of fixing the remote controller on a wall, place where the indoor unit can   receive signals when the fluorescent lamps in the room are lightened.   Power Source   ● Before inserting power plug into receptacle, check the voltage without fail.   corresponding name plate.   Outdoor Unit   The power source is the same as the   ● Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.   ● Place, possible to bear the unit, where vibration and noise are not increased.   ● Place, where discharged wind and noise do not cause a nuisance to the neighbors.   ● Install an exclusive branch circuit of the power.   ● A receptacle shall be set up in a distance where the power cable can be   reached.Do not extend the cable by cutting it.   ● Place, where a distance marked   is available as illustrated in the above figure.    Drawing for the installation of indoor and outdoor units   The models adopt HFC free refrigerant R410A   Attention must be paid to   the rising up of drain hose   more than 5cm   Optional parts for piping   Non-adhesive tape   Adhesive tape   A B G more than   10cm   Saddle (L.S) with screws   C Connecting electric cable   for indoor and outdoor   Drain hose   D E F Heating insulating material   Piping hole cover   G Arrangement of piping   directions   more than 10cm   F Rear left   Floor fixing dimensions of the   A Rear   Left   outdoor unit (Unit:mm)   right   Right   C Below   113.5   113.5   583   more than   10cm   more than 10cm   Fixing of outdoor unit   ● Fix the unit to concrete or block   with bolts (10mm) and nuts firmly   and horizontally.   A ● The marks from   to   G in the figure are the   parts numbers.   ● When fitting the unit to wall   surface, roof or rooftop, fix   a supporter surely with nails   or wires in consideration of   earthquake and strong wind.   ● If vibration may affect the   house, fix the unit by attaching a   vibration-proof mat.   The distance between   the indoor unit and the   floor should be more   than 2m.   ● D E more than   60cm   more than15cm   Please be subject to the actual product purchased , the above picture is just for your reference.   Read this manual before installation   Explain sufficiently the operating means to the user according to this manual   NO.0010506358   Download from Www.Somanuals.com. All Manuals Search And Download.   Outdoor unit   1 Installation of Outdoor Unit   outdoor units   Install according to Drawing for the installation of indoor and   2 Connection of pipes   ● To bend a pipe, give the roundness as large as possible not to crush the pipe ,   Indoor unit   mm or longer.   POWER   and the bending radius should be 30 to 40   ● Connecting the pipe of gas side first makes working easier.   ● The connection pipe is specialized for R410A.   Outdoor unit   Forced fastening without careful centering may   damage the threads and cause a leakage of gas.   Half union   Flare nut   3G2.5mm2   Power cable:   Connecting wiring:   Pipe Diameter(ǿ)   Liquid side6.35mm(1/4")   Liquid/Gas side9.52mm(3/8")   Gas side 12.7mm(1/2")   Gas side 15.88mm(5/8")   Fastening torque   18N.m   6G0.75mm   42 N.m   /R2   HSU-22HEA03   55N.m   HSU-22HRA03/R2   Spanner   Torque wrench   60 N.m   Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.   The standard pipe length is 5m. If it is over 7m, the function of the unit will be   affected. If the pipe has to be lengthened, the refrigerant should be charged,   be conducted by profes-   according to 20 g/m. But the charge of refrigerant must   sional air conditioner engineer. Before adding additional refrigerant, perform air   purging from the refrigerant pipes and indoor unit using a vacuum pump,then   charge additional refrigerant.   CAUTION   Outdoor unit   Indoor unit   Outdoor unit   Indoor unit   B B A Power cable: ≥3G2.5mm2   Connecting wiring:   Indoor unit   A ≥3G1.5mm 2   (For: L N )+2x0.75mm2   Outdoor unit   Amax=15m   Max.Elevation:   ● ● HSU-18RM03/R2   HSU-18HEA03/R2-I   HSU-18HRA103/R2   In case the elevation A is more   than 5m, oil trap shoud be   installed every 5~7m   Outdoor unit   ● ● Max. Length:   Bmax=25m   Oil trap   B In case the pipe length B is   more than 7m, the refrigerant   should be charged, according   to 20 g/m.   Indoor unit   A 1. If the supply cord is damaged, it must be replaced by the manufacturer or its   service agent or a similar qualified person. The type of connecting wire is   H05RN-F or H07RN-F.   2. If the fuse on PC board is broken please change it with the   T. 3.15A/250V.   3. The wiring method should be in line with the local wiring standard.   4. After installation, the power plug should be easily reached.   type of   3 Connection   ● Use the same method on indoor unit. Loosen the screws on   terminal block and   5. A breaker should be incorporated into fixed wiring. The breaker should be   all-pole switch and the distance between its two contacts should be not less   insert the plugs fully into terminal block, then tighten the screws.   than 3mm.   ● Insert the cable according to terminal number in the same manner as the indoor   unit.   ● If wiring is not correct, proper operation can not be carried out and controller   may be damaged.   ● Fix the cable with a clamp.   4 5 Attaching Drain-Elbow   ● If the drain-elbow is used,   please attach it as figure. (Note:   Only for heat pump unit.)   Purging Method:To use vacuum pump   1. Detach the service port’s cap of   3-way valve, the valve rod’s cap for 2-way valve   and 3-way’s, connect the service port into the projection of charge hose (Iow)   for gaugemanifold. Then connect the projection of charge hose (center) for gau-   gemanifold into vacuum pump.   gaugemanifold, operate vacuum pump. If the scale-   2.Open the handle at Iow in   moves of gause (Iow) reach vacuum condition in a moment, check 1. again.   Vacuumize for over 15min.And check the level gauge which should read -0.1MPa   3.   completion of vacuumizing, close the   pressure side. After the   (76 cm Hg) at Iow   handle ‘Lo’ in gaugemanifold and stop the operation of the vacuum pump. Check   condition of the scale and hold it for 1-2min. If the scale-moves back in spite of   tightening, make flaring work again, the return to the beginning of 3 .   anticlockwise 90 degrees.   4.Open the valve rod for the 2-way valve to an angle of   3 Download from Www.Somanuals.com. All Manuals Search And Download.   inspection of gas leakage.   After 6 seconds, close the 2-way valve and make the   5. No gas leakage?   Correct   Incorrect   In case of gas leakage, tighten parts of pipe connection. If   leakage stops, then proceed 6. steps   Lean   Damage of flare Crack   Partial Too outside   from the service   If it does not stop gas leakage, discharge whole refrigerants   port. After flaring work again and vacuumize, fill up prescribed   refrigerant from the gas cylinder.   3 On Drainage   Please install the drain hose so as to be downward slope without fail.   Please don’t do the drainage as shown below.   ● ● open 2-way valve and 3-way. Turn   6.Detach the charge hose   from the service port,   the valve rod anticlockwiseuntil hitting lightly.   port’s cap, the valve rod’s cap for 2-way   leakage, turn the service   valve and 3-way’s a little more   To prevent the gas   7.   Less than   5cm   than the point where the torque increases suddenly.   After attaching the each caps, check the gas leakage around the caps.   8.   It becomes   The end is imm-   ersed in water.   It waves.   The gap with the There is the bad   ground is too smal smell from a ditch   high midway.   Step 1.   Step 2.   Open   2-way valve Liquid Side   3-way valve Gas Side   confirm that drainage   Please pour water in the drain pan of the indoor unit, and   is carried out surely to outdoor.   In case that the attached drain hose is in a room, please   it without fail.   ● ● apply heat insulation to   Gaugemanifold(for   R410A)   Anti countercurrent joint   Step 3.   Close   ■Refrigerant charge label   Vacuum pump(for R410A)   Contains fluorinated greenhouse gases   covered by the Kyoto Protocol   Tube(for R410A)   Step 4.   A Step 6.   2-way valve   3-way valve   2-way valve   3-way valve   1=   2=   kg   kg   R410A   B C 2 Open 90O   1 1+2=   kg   2-way valve   3-way valve   D Step 7.   3-way valve   2-way valve   F E This product contains fluorinated greenhouse gases covered by   the Kyoto Protocol. Do not vent into the atmosphere.   Refrigerant type:R410A   Valve rod cap   Valve rod cap   GWP* value:1975   Service port cap   GWP=global warming potential   Please fill in with indelible ink,   • 1   • 2   the factory refrigerant charge of the product   the additional refrigerant amount charged in the field and   CAUTION   ● ● If the refrigerant of the air conditioner leaks, it is necessary to discharge all the   • 1+2 the total refrigerant charge   refrigerant. Vacuumize first, then   charge the liquid refrigerant into air conditio-   on the refrigerant charge label supplied with the product.   The filled out label must be adhered in the proximity of the product   charging port (e.g. onto the inside of the stop value cover).   A contains fluorinated greenhouse gases covered by the Kyoto   Protocol   ner according to the amount marked on the name plate.   Please do not let other cooling medium, except specified one (R410A), or air   enter into the cooling circulation system. Otherwise, there will be abnormal   high pressure in the system to make it crack and lead to personal injuries.   B factory refrigerant charge of the product: see unit name plate   C D E F additional refrigerant amount charged in the field   total refrigerant charge   outdoor unit   1 Power Source Installation   ● The power source must be exclusively used for air   conditioner. (Over I0A)   refrigerant cylinder and manifold for charging   please install an ea-   ● In the case of installing an air conditioner in a moist place,   rth leakage breaker.   ● as possible.   For installation in other places, use a circuit breaker as far   ■Check for Installation and Test Run   2 Cutting and Flaring Work of Piping   Please kindly explain to our customers how to operate   through the instruction manual.   ■ ● Pipe cutting is carried out with a pipe cutter and burs must be removed.   ● After inserting the flare nut, flaring work is carried out.   Check Items for Test Run   Flare tool for R410A   Clutch-type   Conventional flare tool   Put check mark   in boxes   clutch-type(Rigid-type) Wing-nut type (Imperial-type)   Gas leak from pipe connecting?   Heat insulation of pipe connecting?   Are the connecting wirings of indoor and outdoor firmly   inserted to the terminal block?   Is the connecting wiring of indoor and outdoor firmly fixed?   A 0~0.5mm   1.0~1.5mm   1.Cut pipe   1.5~2.0mm   2.Remove burs   Flare tooling die   Is drainage securely carried out?   Is the earth line securely connected?   Is the indoor unit securely fixed?   Is power source voltage abided by the code?   Is there any noise?   Is the lamp normally lighting?   3.Insert the flare nut   4.Flare pipe   Are cooling and heating (when in heat pump) performed normally?   Is the operation of room temperature regulator normal?   Download from Www.Somanuals.com. All Manuals Search And Download.   4 |