Fujitsu Server TX200 S6 User Manual

Operating Manual - English  
PRIMERGY TX200 S6  
Server  
Operating Manual  
Edition July 2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before reading this manual  
For your safety  
This manual contains important information for safely and correctly using this  
product.  
Carefully read the manual before using this product. Pay particular attention to  
the accompanying manual "Safety notes and other important information" and  
ensure these safety notes are understood before using the product. Keep this  
manual and the manual "Safety notes and other important information" in a safe  
place for easy reference while using this product.  
Radio interference  
This product is a "Class A" ITE (Information Technology Equipment). In a  
domestic environment this product may cause radio interference, in which case  
the user may be required to take appropriate measures.  
VCCI-A  
Aluminum electrolytic capacitors  
The aluminum electrolytic capacitors used in the product's printed circuit board  
assemblies and in the mouse and keyboard are limited-life components. Use of  
these components beyond their operating life may result in electrolyte leakage  
or depletion, potentially causing emission of foul odor or smoke.  
As a guideline, in a normal office environment (25°C) operating life is not  
expected to be reached within the maintenance support period (5 years).  
However, operating life may be reached more quickly if, for example, the product  
is used in a hot environment. The customer shall bear the cost of replacing  
replaceable components which have exceeded their operating life. Note that  
these are only guidelines, and do not constitute a guarantee of trouble-free  
operation during the maintenance support period.  
High safety use  
This product has been designed and manufactured for general uses such as  
general office use, personal use, domestic use and normal industrial use. It has  
not been designed or manufactured for uses which demand an extremely high  
level of safety and carry a direct and serious risk to life or body if such safety  
cannot be ensured.  
TX200 S6  
Operating Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
These uses include control of nuclear reactions in nuclear power plants,  
automatic airplane flight control, air traffic control, traffic control in mass  
transport systems, medical devices for life support, and missile guidance control  
in weapons systems (hereafter, "high safety use"). Customers should not use  
this product for high safety use unless measures are in place for ensuring the  
level of safety demanded of such use. Please consult the sales staff of Fujitsu if  
intending to use this product for high safety use.  
Measures against momentary voltage drop  
This product may be affected by a momentary voltage drop in the power supply  
caused by lightning. To prevent a momentary voltage drop, use of an AC  
uninterruptible power supply is recommended.  
(This notice follows the guidelines of Voltage Dip Immunity of Personal  
Computer issued by JEITA, the Japan Electronics and Information Technology  
Industries Association.)  
Technology controlled by the Foreign Exchange and Foreign Trade  
Control Law of Japan  
Documents produced by Fujitsu may contain technology controlled by the  
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which  
contain such technology should not be exported from Japan or transferred to  
non-residents of Japan without first obtaining authorization in accordance with  
the above law.  
Harmonic Current Standards  
This product conforms to harmonic current standard JIS C 61000-3-2.  
Only for the Japanese market:  
About SATA hard disk drives  
The SATA version of this server supports hard disk drives with SATA / BC-SATA  
storage interfaces. Please note that the usage and operation conditions differ  
depending on the type of hard disk drive used.  
Please refer to the following internet address for further information on the  
usage and operation conditions of each available type of hard disk drive:  
http://primeserver.fujitsu.com/primergy/harddisk/  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Only for the Japanese market:  
I
Although described in this manual, some sections do not apply to the  
Japanese market. These options and routines include:  
USB Flash Module (UFM)  
CSS (Customer Self Service)  
TX200 S6  
Operating Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Contents  
4.3.2  
Installation in PRIMECENTER/DataCenter/  
TX200 S6  
Operating Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Configuring the server and installing the operating system  
5.4.3  
Configuring the server and installing the operating system  
5.4.4  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Contents  
8.2.1  
Opening the server and identifying the defective  
TX200 S6  
Operating Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Preface  
The PRIMERGY TX200 S6 server is an Intel-based server for mid-size and  
large companies. The server is suitable for use as a file server and also as an  
application, information or Internet server. It is available as a floorstand or rack  
model. The floorstand model can be converted to a rack model using an optional  
conversion kit.  
Due to its advanced hardware and software components, the PRIMERGY  
TX200 S6 server offers a high level of data security and availability. These  
components include hot-plug HDD modules, optional hot-plug power supply  
units, optional redundant system fans, the Server Management ServerView  
Suite, Prefailure Detection and Analysis (PDA) and Automatic Server  
Reconfiguration and Restart (ASR&R).  
Security functions in the BIOS-Setup and on the system board protect the data  
on the server against manipulation. Additional security is provided by the  
intrusion detection and the completely lockable chassis of the floorstand model  
or the lockable rack door.  
The rack model occupies 5 height units in the rack.  
TX200 S6  
Operating Manual  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Preface  
1.1  
Concept and target groups for this manual  
This operating manual describes how to install, set up and operate your server.  
This operating manual is intended for those responsible for installing the  
hardware and ensuring that the system runs smoothly. It contains all the  
information you need to put your PRIMERGY TX200 S6 into operation.  
To understand the various expansion options, you will need to be familiar with  
the fields of hardware and data transmission and you will require a basic  
knowledge of the underlying operating system.  
1.2  
Documentation overview  
More information on your PRIMERGY TX200 S6 can be found in the following  
documents:  
"Quick Start Hardware - PRIMERGY TX200 S6" leaflet  
" はじめにお読みください -PRIMERGY TX200 S6" for the Japanese market  
(only included as a printed copy)  
"Quick Start Software - Quick Installation Guide" DVD booklet  
(only included with the ServerView Suite as a printed copy) except for the  
Japanese market  
"Safety notes and other important information" manual  
" 安全上の注意およびその他の重要情報 " for the Japanese market  
"Warranty" manual  
" 保証書 " for the Japanese market  
"ServerView Suite Local Service Concept - LSC" manual  
"Returning used devices" manual and "Service Desk" leaflet  
" サポート&サービス " for the Japanese market  
"PRIMERGY TX200 S6 Server Operating Manual"  
"PRIMERGY TX200 S6 Server Options Guide"  
"System Board D2799 for PRIMERGY TX200 S6 Technical Manual"  
"D2799 BIOS Setup Utility for TX200 S6" manual  
12  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
       
Preface  
I
PRIMERGY manuals are available in PDF format on the  
ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the  
ServerView Suite supplied with every server.  
relevant current versions using the order number U15000-C289 (the  
order number for the Japanese market: please refer to the configurator  
of the server http://primeserver.fujitsu.com/primergy/system.html).  
from the Internet. The overview page showing the online documentation  
available on the Internet can be found using the URL (for EMEA market):  
http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can  
be accessed using the Industry standard servers navigation option.  
http://primeserver.fujitsu.com/primergy/manual.html.  
Further sources of information:  
PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2  
Manual for the monitor  
Documentation for the boards and drives  
Operating system documentation  
Information files in your operating system  
TX200 S6  
Operating Manual  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preface  
1.3  
Features  
Customer Self Service (CSS)  
The PRIMERGY Customer Self Service (CSS) concept enables you to identify  
and replace the affected component yourself in the case of certain error  
scenarios.  
In the CSS concept, you can replace the following components yourself in the  
event of an error:  
Hot-plug hard disk drives  
Hot-plug power supply units  
Memory modules  
System fans  
Expansion cards  
For information on replacing these components, see chapter "CSS  
CSS indicators on the control panel and on the back of the PRIMERGY server  
provide you with information if a CSS event arises (for more information on the  
behavior of these indicators, see chapter "Starting up and operation" on  
page 65 and the "ServerView Suite Local Service Concept - LSC" manual on  
the ServerView Suite DVD 2).  
You can also fit your server with a ServerView Local Service Panel, which  
enables you to identify the type of component affected by the error directly on  
the server (for more information, see the "ServerView Suite Local Service  
Concept - LSC" manual on the ServerView Suite DVD 2).  
In addition, CSS errors are displayed in the ServerView Operations Manager,  
the server management software from Fujitsu.  
In the event of errors, the ServerView Operations Manager refers you directly to  
the affected component and its order information in the Illustrated Spares  
catalog of the server in question. (This feature is not available for the Japanese  
market.)  
14  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
     
Preface  
System board  
The features of the system board are described in the technical manual for the  
system board D2799 for the hardware and in the BIOS Setup manual for the  
firmware.  
Trusted Platform Module (TPM)  
A Trusted Platform Module (TPM) for safer storage of keys can be implemented  
as an option. This module enables programs from third party manufacturers to  
store key information (e.g. drive encryption using Windows Bitlocker Drive  
Encryption).  
The TPM is activated via the BIOS system (for more information, refer to the  
“D2799 BIOS Setup Utility for TX200 S6" manual).  
V
CAUTION!  
When using the TPM, note the program descriptions provided by the  
third party manufacturers.  
You must also create a backup of the TPM content. To do this, follow  
the third party manufacturer's instructions. Without this backup, if the  
TPM or the system board is faulty you will not be able to access your  
data.  
If a failure occurs, please inform your service about the TPM  
activation before it takes any action, and be prepared to provide them  
with your backup copies of the TPM content.  
Slots for expansion cards  
The server can be expanded flexibly via six slots (one 32-bit PCI, two  
PCIe Gen2 x8, and three PCIe Gen2 x4).  
PCIe Gen2 doubles the bandwidth of currently existing PCIe busses and allows  
improved system performance.  
TX200 S6  
Operating Manual  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Preface  
Hard disk drives  
The server is shipped with one of the following drive cages:  
For up to four 3.5-inch SAS/SATA hard disk drives:  
Up to four SAS/SATA HDD modules can be used in the drive cage. Each  
HDD module can accommodate a SAS/SATA hard disk drive with a  
maximum height of 1 inch. The module is connected to the SAS/SATA  
backplane wirelessly. This allows HDD modules to be plugged in and pulled  
out easily.  
As an option, a hard disk extension box (with a maximum of two SAS/SATA  
HDD modules) can be installed (see section "Accessible drives" on  
page 18).  
I
Up to four SATA hard disk drives are controlled by the onboard SATA  
controller. An additional SAS/SATA RAIDcontroller must be installed  
to control additional SATA hard disk drives or SAS hard disk drives.  
For up to eight 2.5-inch SAS/SATA hard disk drives:  
Up to eight SAS/SATA HDD modules can be used in the drive cage. Each  
HDD module can accommodate an SAS/SATA hard disk drive with a 2.5-  
inch format. The modules are connected to the SAS/SATA backplane  
wirelessly. This allows HDD modules to be plugged in or pulled out easily.  
As an option, a hard disk extension box (with a maximum of eight SAS/SATA  
HDD modules) can also be installed (see section "Accessible drives" on  
page 18).  
I
Up to eight SAS/SATA hard disk drives are controlled by the  
SAS/SATA RAID controller already installed.The hard disk extension  
box for 2.5-inch SAS hard disk drives requires an additional  
SAS/SATA RAID controller.  
If the server has the corresponding RAID configuration, HDD modules can also  
be replaced during operation.  
16  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Preface  
Onboard SATA controller  
A SATA controller is integrated on the system board; up to four SATA hard disk  
drives can be connected to the controller. The LSI Embedded MegaRAID  
software (SATA Software RAID) supports RAID levels 0, 1 and 10.  
For more information on configuring the controller, see section "Configuring the  
SAS/SATA RAID controller  
The server is available with the following SAS/SATA RAID controllers for  
operating the internal SAS/SATA hard disk drives:  
Modular RAID 0/1 controller with "Integrated Mirroring Enhanced"  
(SAS IME) for SAS1.0  
RAID levels 0, 1 and 1E are supported for internal hard disk drive  
configurations.  
I
For the Japanese market only RAID level 1 is supported for internal  
hard disk drive configurations.  
Modular RAID 0/1 controller with “MegaRAID functionality”  
(SAS MegaRAID) for SAS1.0 and SAS2.0  
RAID levels 0, 1,10 and 1E are supported for internal hard disk drive  
configurations.  
Modular RAID 5/6 controller with "MegaRAID functionality"  
(SAS MegaRAID) for SAS1.0 and SAS2.0  
RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are supported for internal hard disk  
drive configurations. As an option, a battery backup unit (BBU) can save the  
memory content even if the power fails. Cache memory size of 512 Mbyte is  
available.  
For more information on configuring the controller, see section  
Further information on SAS/SATA RAID controllers is provided in the  
"Modular RAID Controller Installation Guide" (on ServerView Suite  
DVD 2 under Industry Standard Servers - Expansion Cards - Storage Adapters  
- LSI RAID / SCSI Controllers).  
TX200 S6  
Operating Manual  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Preface  
Further information on other SAS/SATA RAID controllers (e.g. for  
operating external SAS/SATA hard disk drives or tape drives) is available  
on ServerView Suite DVD 2 under Industry Standard Servers - Expansion  
Cards - Storage Adapters - LSI RAID / SCSI Controllers.  
Accessible drives  
The server has three 5.25-inch bays that can be used in various ways:  
The individual bays can be equipped with any 3.5-inch drives (height:1.6 inch).  
You can install a multibay (DVD-LSD/LSP) in the top bay. You can install a  
slimline DVD drive and the ServerView Local Service Display or ServerView  
Local Service Panel in the multibay (DVD-LSD/LSP).  
The following expansion boxes are also available depending on the hard disk  
configuration selected:  
With one drive cage for up to two 3.5-inch SAS hard disk drives:  
You can install an extension box for up to two 3.5-inch SAS hard disk drives  
in the two bottom bays. This box has bays for a slimline DVD drive, the  
ServerView Local Service Display/ServerView Local Service Panel, and up  
to two 3.5-inch SAS hard disk drives.  
With a drive cage for up to eight 2.5-inch SAS/SATA hard disk drives:  
You can install an extension box for up to eight 2.5-inch SAS/SATA hard disk  
drives in the two bottom bays.  
I
The HDD extension box for 2.5-inch SAS/SATA hard disk drives  
requires an additional SAS/SATA RAID controller.  
I
Please note the following:  
A DVD drive must have been installed in order to operate the server.  
The accessible drives cannot be replaced during operation.  
Access to the accessible drives may have to be free in order to  
page 65).  
18  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
Preface  
Power supply  
In its basic configuration the server has a permanently installed power supply  
unit or a hot-plug power supply unit that adjusts automatically to any mains  
voltage in the range 100 V - 240 V. Besides the hot-plug power supply unit, a  
second hot-plug power supply unit can be installed optionally to serve as a  
redundant power supply. If one power supply unit fails, the second power supply  
unit in the redundant configuration ensures operation can continue  
uninterrupted. The faulty power supply unit can be replaced during operation  
(for further details see section "Hot-plug power supply units (optional)" on  
page 92).  
Cooling  
In the standard configuration the server is cooled by two system fans and one  
power supply fan.  
In the optional, redundant configuration the server is cooled by four system fans  
(two double fans) and one or two power supply fans. If one of the four system  
fans fails, one of the two predetermined fans (system fan 3 and system fan 4,  
see the "Options Guide" for the system) increases its power to ensure that the  
server is cooled properly.  
TX200 S6  
Operating Manual  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
High level of availability and data security  
When memory data is accessed, 1-bit errors are identified in the main memory  
and automatically corrected with the error correcting code (ECC) method. The  
patented memory scrubbing function regularly starts up the EDC mechanism,  
ensuring continuous data integrity.  
The RDIMM memory modules used support SDDC technology (Chipkill™),  
which further increases the effectiveness of memory error monitoring and  
correction.  
Memory modules can be protected against failure by mirroring (Memory  
Mirroring). Memory Mirroring is roughly comparable to RAID level 1 for hard disk  
arrays. The basic configuration requires two identical memory modules in two  
different banks.  
Support is likewise provided for hot-spare memory technology, in which a  
memory bank is used like a replacement bank. If a memory module fails, the  
bank with the defective memory is automatically deactivated and the  
replacement bank is activated (provided it has been configured for appropriately  
in the BIOS). The deactivated memory bank is no longer used and the faulty  
memory module can be replaced during the next system maintenance. In order  
to be able to use the hot-spare memory function, all occupied memory banks  
have to be equipped with identical memory modules.  
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in  
the event of an error and automatically "hides" the defective system  
components.  
The PDA (Prefailure Detection and Analysis) technology from Fujitsu  
Technology Solutions analyzes and monitors all components that are critical for  
system reliability.  
Optional RAID controllers support RAID levels like 0, 1, 5, ... and increase  
system availability.  
The hot-plug HDD modules provide additional availability.  
20  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
           
Preface  
iRMC S2 with integrated management LAN connector  
I
The features of the iRMC S2 Advanced Video Redirection and Remote  
Storage are available as an option.  
The iRMC S2 (integrated Remote Management Controller) is a BMC with  
integrated management LAN connector and expanded functionality that was  
previously only available with additional plug-in cards. In this way, the iRMC S2  
enables complete control of PRIMERGY servers, regardless of system status,  
and thus particularly the control of PRIMERGY servers that are in the "out-of-  
band" system status.  
Major functions supported by the iRMC S2 include the following:  
Browser access via iRMC S2-s own Web server  
Secure communication (SSH, SSL)  
Power Management for the managed server (depending on its system  
status)  
Power Consumption Management  
Connecting virtual drives as remote storage  
Text-based and graphic console bypass (Advanced Video Redirection)  
Command Line Interface (CLI)  
Simple, interactive or script-based iRMC S2 configuration  
Customer Self Service (CSS)  
iRMC S2-s own user management  
Multi-computer, global iRMC S2 user administration using an LDAP  
Directory Service  
Automatic network configuration via DNS / DHCP  
Power supply of the iRMC S2 via the system standby supply  
Full-coverage alarm management  
System Event Log (SEL) reading and processing  
More information about the iRMC S2 can be found in the "iRMC S2 - integrated  
Remote Management Controller" user’s guide (on the ServerView Suite DVD 2  
under Industry Standard Servers - Software - ServerView Suite - Out-Of-Band  
Management).  
TX200 S6  
Operating Manual  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Preface  
Server management  
Server management is implemented using the ServerView Operations Manager  
supplied and the PDA (Prefailure Detection and Analysis) technology from  
Fujitsu. PDA reports the threat of a system error or overload at an early stage,  
allowing preventive measures to be taken.  
The ServerView Operations Manager enables the management of all  
PRIMERGY servers in the network via a central console. The ServerView  
Operations Manager supports the following functions:  
Round-the-clock monitoring, regardless of server status  
High-performance, graphical console bypass (AVR) protected by  
HTTPS/SSL (128 bit)  
Remote storage via USB  
Remote power on  
Intrusion detection in the floorstand model  
Temperature monitoring of the CPU and the surrounding area  
Detailed status and error reports for processors and main memory  
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)  
in the event that memory modules or processors fail  
Power monitoring  
End-of-life monitoring of fans with prompt notification before failure  
Watchdog timer for monitoring the operating system with ASR&R  
Further information on the ServerView Operations Manager is provided in the  
associated documentation.  
22  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
     
Preface  
ServerView Installation Manager  
You can configure the PRIMERGY server quickly and precisely with the  
ServerView Installation Manager software provided. User-guided menus are  
available for installing the server operating system (for further details see  
Service and support  
PRIMERGY servers are easy to maintain and modular, thus enabling quick and  
simple maintenance.  
The handles and locks (touch point) used to exchange components are colored  
green to ensure simple and immediate recognition.  
In order to prevent the components from being damaged by incorrect handling  
when they are being installed and removed, the areas of all components that  
can be touched without damaging them are also marked green.  
PRIMERGY diagnostic LEDs fitted on the system board show which component  
(memory module, processor, fan or expansion card) is not functioning properly.  
The Flash EPROM program supplied with the Fujitsu utilities supports a fast  
BIOS update.  
With the iRMC S2 (integrated Remote Management Controller) on the system  
board, the PRIMERGY TX200 S6 server can also be maintained and serviced  
remotely. This enables remote diagnosis for system analysis, remote  
configuration and remote restart should the operating system or hardware fail.  
TX200 S6  
Operating Manual  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Preface  
ServerView Remote Management  
ServerView Remote Management is the remote management solution from  
Fujitsu for PRIMERGY servers. ServerView Remote Management and the  
relevant hardware components integrated on the system board allow remote  
monitoring and maintenance as well as fast restoration of operation in the event  
of errors.  
Remote monitoring and maintenance avoids time-consuming and costly on-site  
repairs and reduces service costs. This leads to a reduction in the total cost of  
ownership and an excellent return on investment for the remote management  
solution.  
The administrator can access all system information and information from the  
sensors such as fan speeds or voltages via the iRMC S2's Web interface (see  
You can also start the text-based or graphic console bypass (Advanced Video  
Redirection, AVR) and connect virtual drives as remote storage.  
I
The features of the iRMC S2 Advanced Video Redirection and Remote  
Storage are available as an option.  
More information about the iRMC S2 can be found in the "iRMC S2 -  
integrated Remote Management Controller" user’s guide (on the  
ServerView Suite DVD 2 under Industry Standard Servers - Software -  
ServerView Suite - Out-Of-Band Management).  
24  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
Preface  
1.4  
Notational conventions  
The following notational conventions are used in this manual:  
Text in italics indicates commands or menu items.  
"Quotation marks" indicate names of chapters and terms that are being  
emphasized.  
Ê
describes activities that must be performed in the order  
shown.  
V
CAUTION! pay particular attention to texts marked with this symbol.  
Failure to observe this warning may endanger your life,  
destroy the system or lead to the loss of data.  
I
indicates additional information, notes and tips.  
TX200 S6  
Operating Manual  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Preface  
1.5  
Technical data  
Electrical data  
Rated voltage range  
Frequency  
100 V - 240 V  
47 Hz - 63 Hz  
Rated current with basic configuration 100 V oder 240 V / 1.3 A - 0.6 A  
Max. rated current  
100 V - 127 V oder 200 V - 240 V /  
9.5 A - 4.0 A  
Effective power  
Apparent power  
Heat dissipation  
Main power fuse  
Protection class  
max. 461 W  
max. 490 VA  
1659.6 kJ/h (1573 BTU)  
16 A  
I
Compliance with regulations and standards  
Product safety and  
ergonomics  
IEC 60950-1 / EN 60950-1, UL/CSA 60950-1,  
CNS 14336 / GB 4943 / EN 50371  
Electromagnetic  
compatibility  
FCC class A  
CNS 13438 class A; VCCI class A  
AS/NZS CISPR 22 class A / GB 9254 class A  
GB 17625  
interference emissions EN 55022 class A  
Harmonic current EN 61000-3-2  
Flicker  
EN 61000-3-3  
interference immunity EN 55024, EN 300386  
CE marking Low Voltage Directive 2006/95/EC  
to EU directives (product safety)  
Electromagnetic compatibility 2004/108/EC  
Mechanicalenvironmental EN 60721-3-3; class 3M2  
conditions  
26  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
         
Preface  
Mechanical specifications  
Floorstand  
Width (with anti-tilt bracket) 205 mm (306 mm)  
Rack  
482 mm  
570 mm  
596 mm  
5 HU  
Total depth  
584 mm  
-----  
Installation depth  
Height  
444 mm  
Dimension notes  
Floorstand width 306 mm with tilt protection;  
depth measured excludes handles on redundant  
PSU. Rack depth excludes handles of  
redundant PSU and rack front.  
Weight  
max. 36.8 kg (depending on configuration).  
Ventilation clearance  
At least 200 mm on the front and rear.  
Maintenance area for the floorstand model  
1.2 m2 on the left side. Emergency access must be assured.  
Ambient conditions  
Environment class 3K2  
Environment class 2K2  
EN 60721 / IEC 721 Part 3-3  
EN 60721 / IEC 721 Part 3-2  
Temperature:  
Operation (3K2)  
Transport (2K2)  
Humidity  
10 °C .... 35 °C  
-25 °C .... 60 °C  
10% .... 85% (non condensing)  
Condensation during operation must be avoided!  
TX200 S6  
Operating Manual  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Preface  
Noise level with standard fan and standard power supply units  
Sound power level LWAd (ISO 9296)  
5.2 B (standby)  
5.7 B (operating)  
Sound pressure level at adjacent position  
LpAm (ISO 9296)  
34 dB (A) (standby)  
36 dB (A) (operating)  
Noise level with redundant system fans and redundant power supply  
Sound power level LWAd (ISO 9296)  
5.5 B (standby)  
5.9 B (operating)  
Sound pressure level at adjacent position  
36 dB (A) (standby)  
39 dB (A) (operating)  
L
pAm (ISO 9296)  
28  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
2
Installation steps, overview  
This chapter contains an overview of the steps you need to carry out to install  
your server. Links take you to sections where you can find more detailed  
information about the respective steps:  
Ê
At first, please take notice of the safety instructions in chapter "Important  
Ê
Unpack the system, check the contents of the package for visible transport  
damage and check whether the items delivered match the details on the  
delivery note (see section "Unpacking the server" on page 46).  
Ê
Ê
Transport the server to the place where you want to set it up.  
Make sure that you have all necessary manuals (see "Documentation  
overview" on page 12); print out the PDF files if required.  
Ê
Ê
Ê
Components that have been ordered additionally may be delivered loose  
with the server. Install these in the server as described in the supplied  
documentation.  
Set up the floorstand model (see section "Setting up the floorstand model"  
on page 47) or install the rack model in the rack (see section  
Wire the server. Follow the instructions in sections "Connecting devices to  
Ê
Ê
Connect the server to the mains (see section "Connecting the server to the  
Familiarize yourself with the controls and indicators on the front and rear of  
TX200 S6  
Operating Manual  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation steps, overview  
Ê
Configure the server and install the desired operating system and  
applications. The following options are available:  
Remote installation with the ServerView Installation Manager:  
With the ServerView Suite DVD 1 provided, you can configure the server  
and install the operating system in a convenient manner.  
Details on how to operate the ServerView Installation Manager, as well  
as some additional information, are included in the "ServerView Suite  
Installation Manager" user’s guide (on ServerView Suite DVD 2 under  
Industry Standard Servers - Software - ServerView Suite - Server Installation  
and Deployment).  
Configuration information can also be found in section "Configuring the  
Local configuration and installation with or without the ServerView  
Installation Manager (see section "Configuring the server and installing  
I
You will find more information on installing the server remotely or  
locally in the "ServerView Suite Installation Manager" user’s guide  
(on the ServerView Suite DVD 2 under Industry Standard Servers -  
Software - ServerView Suite - Server Installation and Deployment).  
30  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
3
Important information  
In this chapter you will find essential information regarding safety when working  
on your server.  
3.1  
Safety instructions  
I
The following safety instructions are also provided in the manual "Safety  
notes and other important information".  
This device meets the relevant safety regulations for IT equipment. If you have  
any questions about whether you can install the server in the intended  
environment, please contact your sales outlet or our customer service team.  
V
CAUTION!  
The actions described in this manual shall be performed by technical  
specialists. A technical specialist is a person who is trained to install  
the server including hardware and software.  
Repairs to the device that do not relate to CSS failures shall be  
performed by service personnel. Please note that unauthorized  
interference with the system will void the warranty and exempt the  
manufacturer from all liability.  
Any failure to observe the guidelines in this manual, and any improper  
repairs could expose the user to risks (electric shock, energy  
hazards, fire hazards) or damage the equipment.  
Before installing/removing internal options to/from the server, turn off  
the server, all peripheral devices, and any other connected devices.  
Also unplug all power cords from the power outlet. Failure to do so  
can cause electric shock.  
TX200 S6  
Operating Manual  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Important information  
Before starting up  
V
CAUTION!  
During installation and before operating the device, observe the  
instructions on environmental conditions for your device (see section  
If the server has been moved from a cold environment, condensation  
may form both inside and on the outside of the machine.  
Wait until the server has acclimatized to room temperature and is  
absolutely dry before starting it up. Material damage may be caused  
to the server if this requirement is not met.  
Only transport the server in the original packaging or in packaging  
that protects it from impacts and jolts.  
Installation and operation  
V
CAUTION!  
This unit should not be operated in ambient temperatures above  
35 °C.  
If the unit is integrated into an installation that draws power from an  
industrial power supply network with an IEC309 connector, the power  
supply's fuse protection must comply with the requirements for non-  
industrial power supply networks for type A connectors.  
The unit automatically adjusts itself to a mains voltage in a range of  
100 V - 240 V. Ensure that the local mains voltage lies within these  
limits.  
This device must only be connected to properly grounded power  
outlets or insulated sockets of the rack's internal power supply with  
tested and approved power cords.  
Ensure that the device is connected to a properly grounded power  
outlet close to the device.  
32  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Important information  
V
CAUTION!  
Ensure that the power sockets on the device and the properly  
grounded power outlets are freely accessible.  
The On/Off button or the main power switch (if present) does not  
isolate the device from the mains power supply. To disconnect it  
completely from the mains power supply, unplug all network power  
plugs from the properly grounded power outlets.  
Always connect the server and the attached peripherals to the same  
power circuit. Otherwise you run the risk of losing data if, for example,  
the server is still running but a peripheral device (e.g. memory  
subsystem) fails during a power outage.  
Data cables must be adequately shielded.  
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2  
standards or ISO/IEC 11801 standard respectively. The minimum  
requirement is a Category 5 shielded cable for 10/100 Ethernet, or a  
Category 5e cable for Gigabit Ethernet.  
Route the cables in such a way that they do not create a potential  
hazard (make sure no-one can trip over them) and that they cannot  
be damaged. When connecting the server, refer to the relevant  
instructions in this manual.  
Never connect or disconnect data transmission lines during a storm  
(risk of lightning hazard).  
Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can  
get inside the server (risk of electric shock, short circuit).  
In emergencies (e.g. damaged casing, controls or cables, penetration  
of liquids or foreign bodies), switch off the server immediately, remove  
all power plugs and contact your sales outlet or customer service  
team.  
TX200 S6  
Operating Manual  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important information  
V
CAUTION!  
Proper operation of the system (in accordance with IEC 60950-1  
resp. EN 60950-1) is only ensured if the casing is completely  
assembled and the rear covers for the installation slots have been  
fitted (electric shock, cooling, fire protection, interference  
suppression).  
Only install system expansions that satisfy the requirements and  
rules governing safety and electromagnetic compatibility and those  
relating to telecommunication terminals. If you install other  
expansions, they may damage the system or violate the safety  
regulations. Information on which system expansions are approved  
for installation can be obtained from our customer service center or  
your sales outlet.  
The components marked with a warning notice (e.g. lightning symbol)  
may only be opened, removed or exchanged by authorized, qualified  
personnel. Exception: CSS components can be replaced.  
The warranty is void if the server is damaged during installation or  
replacement of system expansions.  
Only set screen resolutions and refresh rates that are specified in the  
operating manual for the monitor. Otherwise, you may damage your  
monitor. If you are in any doubt, contact your sales outlet or customer  
service center.  
Before installing/removing internal options to/from the server, turn off  
the server, all peripheral devices, and any other connected devices.  
Also unplug all power cords from the outlet. Failure to do so can  
cause electric shock.  
Do not damage or modify internal cables or devices. Doing so may  
cause a device failure, fire, or electric shock.  
Devices inside the server remain hot after shutdown. Wait for a while  
after shutdown before installing or removing internal options.  
The circuit boards and soldered parts of internal options are exposed  
and can be damaged by static electricity. Before handling them, first  
touch a metal part of the server to discharge static electricity from  
your body.  
Do not touch the circuitry on boards or soldered parts. Hold the  
metallic areas or the edges of the circuit boards.  
34  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Important information  
V
CAUTION!  
Install the screw removed during installation/detaching Internal  
Options in former device/position. To use a screw of the different kind  
causes a breakdown of equipment.  
The installation indicated on this note is sometimes changed to the  
kind of possible options without notice.  
Batteries  
CAUTION!  
V
Incorrect replacement of batteries may lead to a risk of explosion. The  
batteries may only be replaced with identical batteries or with a type  
recommended by the manufacturer (see the technical manual for the  
system board).  
Do not throw batteries into the trash can. They must be disposed of  
in accordance with local regulations concerning special waste.  
The battery must be disposed of in accordance with local regulations  
concerning special waste.  
Replace the lithium battery on the system board in accordance with  
the instructions in the technical manual for the system board.  
All batteries containing pollutants are marked with a symbol (a  
crossed-out garbage can). In addition, the marking is provided with  
the chemical symbol of the heavy metal decisive for the classification  
as a pollutant:  
Cd Cadmium  
Hg Mercury  
Pb Lead  
TX200 S6  
Operating Manual  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Important information  
Working with CDs/DVDs/BDs and optical drives  
When working with devices with optical drives, these instructions must be  
followed.  
V
CAUTION!  
Only use CDs/DVDs/BDs that are in perfect condition, in order to  
prevent data loss, equipment damage and injury.  
Check each CD/DVD/BD for damage, cracks, breakages etc. before  
inserting it in the drive.  
Note that any additional labels applied may change the mechanical  
properties of a CD/DVD/BD and cause imbalance.  
Damaged and imbalanced CDs/DVDs/BDs can break at high drive  
speeds (data loss).  
Under certain circumstances, sharp CD/DVD/BD fragments can  
pierce the cover of the optical drive (equipment damage) and can fly  
out of the device (danger of injury, particularly to uncovered body  
parts such as the face or neck).  
High humidity and airborne dust levels are to be avoided. Electric  
shocks and/or server failures may be caused by liquids such as water,  
or metallic items, such as paper clips, entering a drive.  
Shocks and vibrations are also to be avoided.  
Do not insert any objects other than the specified CDs/DVDs/BDs.  
Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray  
roughly.  
Do not disassemble the optical drive.  
Before use, clean the optical disk tray using a soft, dry cloth.  
As a precaution, remove disks from the optical drive when the drive  
is not to be used for a long time. Keep the optical disk tray closed to  
prevent foreign matter, such as dust, from entering the optical drive.  
Hold CDs/DVDs/BDs by their edges to avoid contact with the disk  
surface.  
36  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Important information  
Do not contaminate the CD/DVD/BD surface with fingerprints, oil,  
dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to  
the edge. Do not use benzene, thinners, water, record sprays,  
antistatic agents, or silicone-impregnated cloth.  
Be careful not to damage the CD/DVD/BD surface.  
Keep the CDs/DVDs/BDs away from heat sources.  
Do not bend or place heavy objects on CDs/DVDs/BDs.  
Do not write with ballpoint pen or pencil on the label (printed) side.  
Do not attach stickers or similar to the label side. Doing so may cause  
rotational eccentricity and abnormal vibrations.  
When a CD/DVD/BD is moved from a cold place to a warm place,  
moisture condensation on the CD/DVD/BD surface can cause data  
read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth  
then let it air dry. Do not dry the CD/DVD/BD using devices such as a  
hair dryer.  
To avoid dust, damage, and deformation, keep the CD/DVD/BD in its  
case whenever it is not in use.  
Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to  
prolonged direct sunlight or near heating appliances are to be  
avoided.  
I
You can prevent damage from the optical drive and the CDs/DVDs/BDs,  
as well as premature wear of the disks, by observing the following  
suggestions:  
Only insert disks in the drive when needed and remove them after  
use.  
Store the disks in suitable sleeves.  
Protect the disks from exposure to heat and direct sunlight.  
Laser information  
The optical drive complies with IEC 60825-1 laser class 1.  
V
CAUTION!  
The optical drive contains a light-emitting diode (LED), which under  
certain circumstances produces a laser beam stronger than laser  
class 1. Looking directly at this beam is dangerous.  
Never remove parts of the optical drive casing!  
TX200 S6  
Operating Manual  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Important information  
Modules with Electrostatic-Sensitive Devices  
Modules with electrostatic-sensitive devices are identified by the following  
sticker:  
Figure 1: ESD label  
When you handle components fitted with ESDs, you must always observe the  
following points:  
Switch off the system and remove the power plugs from the power outlets  
before installing or removing components with ESDs.  
You must always discharge static build-up (e.g. by touching a grounded  
object) before working with such components.  
Any devices or tools that are used must be free of electrostatic charge.  
Wear a suitable grounding cable that connects you to the external chassis of  
the system unit.  
Always hold components with ESDs at the edges or at the points marked  
green (touch points).  
Do not touch any connectors or conduction paths on an ESD.  
Place all the components on a pad which is free of electrostatic charge.  
I
For a detailed description of how to handle ESD components, see the  
relevant European or international standards (EN 61340-5-1,  
ANSI/ESD S20.20).  
38  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
Important information  
Other important information:  
During cleaning, observe the instructions in section "Cleaning the server" on  
Keep this operating manual and the other documentation (such as the  
technical manual, documentation DVD) close to the device. All  
documentation must be included if the equipment is passed on to a third  
party.  
3.2  
ENERGY STAR  
Products that have been certified compliant with ENERGY STAR  
and identified as such are in full compliance with the specification  
at shipping. Note that energy consumption can be affected by  
software that is installed or any changes that are made to the  
BIOS or energy options subsequently. In such cases, the  
properties guaranteed by ENERGY STAR can no longer be  
assured.  
The "ServerView Operations Manager" user guide contains  
instructions for reading out measurement values, including those  
relating to current energy consumption and air temperatures.  
Either the Performance Monitor or the Task Manager can be used  
to read out CPU utilization levels.  
I
A specific model of this product is recognized in United  
States EPA, and registered. The model based on this is  
not sold in the Japanese market.  
TX200 S6  
Operating Manual  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Important information  
3.3  
CE conformity  
The system complies with the requirements of the EC directives  
2004/108/EC regarding "Electromagnetic Compatibility" and  
2006/95/EC "Low Voltage Directive". This is indicated by the CE  
marking (CE = Communauté Européenne).  
3.4  
FCC Class A Compliance Statement  
If there is an FCC statement on the device, it applies to the products covered in  
this manual, unless otherwise specified herein. The statement for other  
products will appear in the accompanying documentation.  
NOTE:  
This equipment has been tested and found to comply with the limits for a  
"Class A" digital device, pursuant to Part 15 of the FCC rules and meets all  
requirements of the Canadian Interference-Causing Equipment Standard  
ICES-003 for digital apparatus. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation. This  
equipment generates, uses and can radiate radio frequency energy and, if not  
installed and used in strict accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no warranty that  
interference will not occur in a particular installation. If this equipment does  
cause harmful interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is encouraged to try  
to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between equipment and the receiver.  
Connect the equipment into an outlet on a circuit different from that to which  
the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
Fujitsu is not responsible for any radio or television interference caused by  
unauthorized modifications of this equipment or the substitution or attachment  
of connecting cables and equipment other than those specified by Fujitsu. The  
correction of interferences caused by such unauthorized modification,  
substitution or attachment will be the responsibility of the user.  
40  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
       
Important information  
The use of shielded I/O cables is required when connecting this equipment to  
any and all optional peripheral or host devices. Failure to do so may violate FCC  
and ICES rules.  
WARNING:  
This is a class A product. In a domestic environment this product may cause  
radio interference in which case the user may be required to take adequate  
measures.  
3.5  
Transporting the server  
V
CAUTION!  
Only transport the server in its original packaging or in packaging that  
protects it from impacts and jolts. Do not unpack the server until it is at  
its installation location.  
If you need to lift or transport the server, ask other people to help you.  
Never lift or carry the device by the handles on the front panel.  
TX200 S6  
Operating Manual  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Important information  
3.6  
Notes on installing the server in the rack  
V
CAUTION!  
For safety reasons, at least two people are required to install the  
server in the rack because of its weight and size.  
(For the Japanese market, please refer to " 安全上の注意およびその  
他の重要情報 ".)  
Never lift the server into the rack using the handles on the front panel.  
When connecting and disconnecting cables, observe the relevant  
instructions in the "Important Information" chapter of the technical  
manual for the corresponding rack. The technical manual is supplied  
with the corresponding rack.  
When installing the rack, make sure that the anti-tilt mechanism is  
correctly fitted.  
For safety reasons, no more than one unit may be removed from the  
rack at any one time during installation and maintenance work.  
If several units are simultaneously removed from the rack, there is a  
risk that the rack could tip over.  
The rack must be connected to the power supply by an authorized  
specialist (electrician).  
If the server is integrated into an installation that draws power from an  
industrial power supply network with an IEC309 type connector, the  
power supply's fuse protection must comply with the requirements for  
non-industrial power supply networks for the type A connector.  
42  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
Important information  
3.7  
Environmental protection  
Environmentally-friendly product design and development  
This product has been designed in accordance with the Fujitsu standard for  
"environmentally friendly product design and development". This means that  
key factors such as durability, selection and labeling of materials, emissions,  
packaging, ease of dismantling and recycling have been taken into account.  
This saves resources and thus reduces the harm done to the environment.  
Further information can be found at:  
http://ts.fujitsu.com/products/standard_servers/index.html (for the EMEA market)  
http://primeserver.fujitsu.com/primergy/concept/ (for the Japanese market)  
Energy-saving information  
Devices that do not need to be constantly switched on should be switched off  
until they are needed as well as during long breaks and after completion of work.  
Packaging information  
This packaging information doesn’t apply to the Japanese market.  
Do not throw away the packaging. You may need it later for transporting the  
system. If possible, the equipment should only be transported in its original  
packaging.  
Information on handling consumables  
Please dispose of printer consumables and batteries in accordance with the  
applicable national regulations.  
In accordance with EU directives, batteries must not be disposed of with  
unsorted domestic waste. They can be returned free of charge to the  
manufacturer, dealer or an authorized agent for recycling or disposal.  
TX200 S6  
Operating Manual  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Important information  
All batteries containing pollutants are marked with a symbol (a crossed-out  
garbage can). They are also marked with the chemical symbol for the heavy  
metal that causes them to be categorized as containing pollutants:  
Cd Cadmium  
Hg Mercury  
Pb Lead  
Labels on plastic casing parts  
Please avoid sticking your own labels on plastic parts wherever possible, since  
this makes it difficult to recycle them.  
Returns, recycling and disposal  
Please handle returns, recycling and disposal in accordance with local  
regulations.  
The device must not be disposed of with domestic waste. This  
device is labeled in compliance with European directive  
2002/96/EC on waste electrical and electronic equipment (WEEE).  
This directive sets the framework for returning and recycling used  
equipment and is valid across the EU. When returning your used  
you. Further information can be found at  
http://ts.fujitsu.com/recycling.  
Details regarding the return and recycling of devices and consumables within  
Europe can also be found in the "Returning used devices" manual, via your local  
Fujitsu branch or from our recycling center in Paderborn:  
Fujitsu Technology Solutions  
Recycling Center  
D-33106 Paderborn  
Tel. +49 5251 8 18010  
Fax +49 5251 8 333 18010  
44  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
4
Hardware installation  
V
CAUTION!  
Follow the safety instructions in the chapter "Important information"  
Do not expose the server to extreme environmental conditions (see  
"Ambient conditions" on page 27). Protect the server from dust,  
humidity and heat.  
Make sure that the server is acclimatized for the time indicated in this  
table before putting it into operation.  
Temperature difference (°C) Minimum acclimatization time  
(hours)  
5
3
5
10  
15  
7
20  
8
25  
30  
9
10  
Table 1: Acclimatization time  
In the table "Acclimatization time", the temperature difference refers  
to the difference between the operating environment temperature and  
the temperature to which the server was exposed previously (outside,  
transport or storage temperature).  
TX200 S6  
Operating Manual  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Hardware installation  
4.1  
Unpacking the server  
V
CAUTION!  
Follow the safety instructions in chapter "Important information" on  
The server must always be lifted or carried by at least two people.  
(For the Japanese market, please refer to " 安全上の注意およびその他の  
重要情報 ".)  
Do not unpack the server until it is at its installation location.  
Ê
Ê
Transport the server to the place where you want to set it up.  
Unpack all individual parts.  
Keep the original packaging in case you want to transport the server again  
(applies only to EMEA market).  
Ê
Ê
Check the delivery for any damage during transport.  
Check whether the items delivered match the details on the delivery note.  
The product name and serial number of the product can be found on the ID card  
(see section "ID card" on page 69).  
Ê
Notify your supplier immediately should you discover that the items delivered  
do not correspond to the delivery note.  
46  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
           
Hardware installation  
4.2  
Setting up the floorstand model  
I
If you are not installing a PRIMERGY TX200 S6 floorstand model, skip  
this section and continue reading at section "Installing/removing the rack  
CAUTION!  
Follow the safety instructions in chapter "Important information" on  
Ê
Ê
Ê
Transport the server to the place where you want to set it up.  
Unpack the server (see section "Unpacking the server" on page 46).  
Set up the server.  
Note that for safety reasons (danger of tipping) the anti-tilt bracket must be  
mounted on the back of the server (see section "Mounting the anti-tilt  
V
CAUTION!  
The device must be protected from direct sunlight.  
The essential minimum clearance for servicing must be  
page 27).  
Access to the rear of the server must be assured so that other  
devices (e.g. memory subsystems) can be connected.  
A clearance of at least 200 mm must be maintained in front of and  
behind the system to ensure proper ventilation.  
The mains plug must be accessible easily and safely.  
Ê
Ê
Wire the server. Read the information in section "Connecting devices to the  
Connect the system to the mains (see section "Connecting the server to the  
TX200 S6  
Operating Manual  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Hardware installation  
4.2.1 Mounting the anti-tilt bracket  
I
The anti-tilt bracket is only necessary for the redundant configuration  
(with two hot-plug power supplies).  
0
0
Figure 2: Mounting the anti-tilt bracket  
Ê
Ê
Place the server on the anti-tilt bracket.  
Fasten the anti-tilt bracket using the two knurled screws (1).  
48  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
Hardware installation  
4.3  
Installing/removing the rack model  
V
CAUTION!  
Please observe the safety information and notes on rack mounting in  
At least two people are needed to install / remove the server in the  
rack. (For the Japanese market, please refer to " 安全上の注意および  
その他の重要情報 ".)  
The rack may tip over if more than one unit is removed at the same  
time.  
The server may not occupy the top height units of the rack  
(38HU/42HU PRIMECENTER Rack, DataCenter Rack,  
19-inch standard rack (for the Japanese market)),  
as otherwise boards cannot be replaced even with the plug-in module  
fully extended.  
4.3.1 Rack system requirements  
The rack systems from Fujitsu PRIMECENTER Rack, DataCenter Rack and  
19-inch standard rack (for the Japanese market) support the installation of  
PRIMERGY servers. Installation in most current rack systems from other  
manufacturers (3rd party racks) is also supported.  
To accommodate the ventilation concept and ensure proper ventilation, any  
unused areas in the rack must be sealed using dummy covers.  
The power is supplied via the multiple socket outlets fitted in the rack.  
Fujitsu rack systems  
The main features of PRIMECENTER Rack, DataCenter Rack and 19-inch  
standard rack (for the Japanese market) are as follows:  
support systems that can be mounted without tools  
support systems having a linear alignment feature to ensure that they can  
be adjusted to different rack depths  
PRIMECENTER Rack and DataCenter Rack provide an enhanced cable  
management in the lateral rack area.  
TX200 S6  
Operating Manual  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Hardware installation  
I
For PRIMECENTER Racks and DataCenter Racks:  
The mounting of the rails in the different racks is described in the next  
sections. Installation of the cable management is described in detail in  
I the Technical Manual for the respective rack.  
For 19-inch standard rack (for the Japanese market):  
For information on mounting of the rails in the 19-inch standard rack (for  
the Japanese market) please refer to the next sections or the " はじめに  
お読みください ".  
3rd party racks  
Certain general conditions must be met:  
Installation dimensions (see the dimensions shown in figure 3 on page 51):  
1
Front of rack  
2
Rear of rack  
A
Rack depth (comparison PRIMECENTER Rack 940/1000/1100 mm)  
Rack width (comparison PRIMECENTER rack 700 mm)  
Clearance for 19" installation level  
Front 19" installation level  
B
C
C1  
C2  
D
Rear 19" installation level  
Cable routing area (cable area depth) and ventilation  
Space for front panel and ventilation  
Space for right and left support systems  
PRIMERGY rack installation depth  
Front left support upright  
E
F
P
a1  
a2  
b1  
b2  
Front right support upright  
Rear left support upright  
Rear right support upright  
50  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
Hardware installation  
+/- 1,6mm  
Figure 3: Mechanical requirements  
TX200 S6  
Operating Manual  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hardware installation  
You must ensure that the safety mechanisms on the server, e.g. stoppers or  
retaining systems, are functioning correctly.  
The shape of the rack support uprights must ensure that the support  
systems can be bolted to the front.  
The support systems have a linear alignment feature to ensure that they can  
be adjusted to different rack depths.  
No cable management support (delivered with the mounting kit).  
Climatic conditions:  
An unobstructed air intake in the rack front and air discharge in the rear  
cover of the rack are essential for ventilation of the installed server.  
In general, the ventilation concept ensures that the necessary cooling is  
achieved by the horizontal self-ventilation of the installed devices (air flow  
from the front to the rear).  
Power supply:  
For installation in 3rd party racks, you must ensure that the appropriate  
socket strips are present.  
4.3.2 Installation in PRIMECENTER/DataCenter/  
19-inch standard rack  
For installation in a PRIMECENTER/DataCenter rack, the following parts are  
required:  
Support bracket (for the EMEA market)  
One support system on the left and one on the right  
M5 centering fixtures (screws with integrated plugwashers)  
I
The descriptions and figures in this section refer to the current  
support system. For other support systems you will find the  
appropriate description in the packaging of the rack mounting kit.  
General information regarding server installation in the rack is  
included in the technical manual for the appropriate rack.  
52  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
Hardware installation  
Fitting the support bracket  
When mounting the left support system in the corresponding rack, the supplied  
support bracket must first be mounted flush with the underside of the device on  
the rear left support upright.  
0
2x  
/
Figure 4: Fitting the support bracket  
Ê
Position the support bracket at the corresponding height on the rear left  
support upright, (place the knobs in the corresponding holes) (1) and secure  
it with the two supplied M5 centering fixtures (2).  
TX200 S6  
Operating Manual  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hardware installation  
Installing the support systems  
Figure 5: Fit the left support system in the PRIMECENTER/DataCenter rack  
Ê
Position the left support system in the support bracket (insert retaining bolts)  
- see (1).  
I
For the Japanese market:  
There is no support bracket. Please position the support system  
directly on the support upright.  
Ê
Clamp the left-hand support system (2) between the front left support  
upright and the support bracket by pressing the support system together,  
positioning it on the front support upright and releasing it again. The support  
system automatically adjusts to the rack depth.  
54  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
Hardware installation  
I
The support system no longer has to be fixed to the front support  
upright because the easy lock engages and ensures a firm fit.  
Ê
Insert (3) the safety lock into the easy lock (snap fit).  
V
CAUTION!  
Ensure that the safety lock has been inserted before the server is  
inserted!  
Ê
Ê
Repeat the above steps for the right-hand support system (with the front and  
rear right support uprights).  
Fit the PRIMECENTER/DataCenter rack cable management as described in  
the technical manual for the corresponding rack.  
15  
10  
5
1
Figure 6: Position of the cage nuts  
Ê
Ê
Fit the cage nuts for securing the server in the corresponding catches on the  
right and left support uprights.  
Insert the server (see "Inserting the server" on page 56).  
TX200 S6  
Operating Manual  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hardware installation  
Inserting the server  
0
Figure 7: Inserting the server (a)  
6
5
4
3
Figure 8: Inserting the server (b)  
56  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
Hardware installation  
V
CAUTION!  
Ensure that the safety lock has been inserted before the server is  
V inserted (see figure 5 on page 54).  
CAUTION!  
At least two people are needed to position the server in the rack.  
(For the Japanese market, please refer to " 安全上の注意およびその他の  
重要情報 ".)  
Ê
Extend the telescopic rails completely to the front (1).  
I
They must click into place so that they can no longer be moved.  
Ê
Lower the server from above onto the projecting telescopic rails (2), (3). As  
you do this, the locking bar (4) engages.  
Ê
Ê
Push the locking mechanism of both telescopic rails up (5).  
For a final function test, slide the server in and out at least twice.The rails  
should move smoothly.  
Ê
Ê
Ê
Push the server as far as it will go into the rack (6).  
Fasten the server to the rack (7) using the two knurled screws (front panel).  
Route the cables as described in the technical manual for the rack in  
question with the server pushed in.  
4.3.3 Installation in 3rd party racks  
I
The support systems from Fujitsu are suitable for use in any 3rd party  
racks for standard servers (installation depth 714 - 785 mm) without  
restrictions.  
Ê
Refer to the manual from the rack manufacturer for details of the mechanical  
installation and the climatic conditions.  
V
CAUTION!  
When installing in 3rd party racks, it must be ensured that an air flow  
from the front to the back of the rack is guaranteed.  
Ê
Fit the required original parts (support bracket or cable management  
system).  
TX200 S6  
Operating Manual  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Hardware installation  
I
Under certain circumstances, you will not be able to use some of the  
parts from the rack installation kit supplied - you will need to use  
original 3rd party rack parts instead.  
Racks with installation depth of 735 mm  
The lengths of the telescopic rails do not need to be adjusted with respect to  
each other for the installation in rack systems with 735 mm installation depth.  
Ê
Secure the support systems as described in section "Installing the support  
Ê
Mount the server (see "Inserting the server" on page 56) and route the  
cables as described in the original manual of the rack.  
V
CAUTION!  
Ensure that the safety lock has been inserted before the server is  
inserted (see figure 5 on page 54).  
Racks with installation depth smaller/greater than 735 mm  
The support systems can be used for installation depths of 714 - 785 mm. The  
spring element of the support system is used to adjust the length as required.  
Ê
Secure the support systems as described in "Installing the support systems"  
Ê
Mount the server (see "Inserting the server" on page 56) and route the  
cables as described in the original manual of the rack.  
V
CAUTION!  
Ensure that the safety lock has been inserted before the server is  
inserted (see figure 5 on page 54).  
58  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Hardware installation  
4.4  
Connecting devices to the server  
The connectors for external devices are on the front and rear of the server. The  
additional connectors available on your server depend on the expansion cards  
installed.  
The standard connectors are indicated by symbols and color coding:  
/
0
3
2
1
Figure 9: Connector panel on the rear side  
1 Management LAN connector (LAN 1)  
2 Shared LAN connector (LAN 2)  
3 USB connectors (black)  
4 Video connector (blue)  
5 Serial connector COM1 (turquoise)  
The corresponding indicators are explained in section "Rear of server" on  
I
Some of the devices connected require special software (e.g. drivers)  
(see documentation for the connected device).  
Ê
Connect the data cables to the server and peripherals.  
Three additional USB connectors are located on the front of the server (see  
figure 15 on page 68).  
TX200 S6  
Operating Manual  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
Hardware installation  
Connecting the monitor  
Ê
Connect the monitor to the video connector of the server (see figure 9 on  
page 59).  
Ê
Connect the power cable of the monitor to a grounded mains outlet of the in-  
house mains and/or to the mains socket strip of the rack.  
V
CAUTION!  
The rated current for the monitor is indicated on the technical data label  
on the monitor or in the operating manual for the monitor.  
4.5  
Connecting the server to the mains  
The server is either equipped with a standard power supply unit or with one or  
two hot-plug power supply units.  
As an option, the standard power supply unit can be replaced with a hot-plug  
power supply unit. A second hot-plug power supply unit can be added to ensure  
a redundant power supply. If a defect occurs in one power supply unit, the other  
power supply unit ensures unimpaired further operation.  
V
CAUTION!  
The server is automatically set to a mains voltage in the range 100 V -  
240 V. You may only operate the server if its rated voltage range  
I corresponds to the local mains voltage.  
A phase redundancy in the power supply of the server can be set up if  
two hot-plug power supply units are installed.  
In this case the two power supply units are directly connected either to  
two different phases or two different power circuits of the in-house mains.  
60  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
         
Hardware installation  
/
0
/
1
Figure 10: Connecting the server to the mains  
Ê
Ê
Connect the power cord to the server power supply unit (1).  
Connect the mains plug to a grounded mains outlet (2) in the in-house power  
supply network or a power outlet of the socket strip (3) in the rack (see  
technical manual for the rack).  
TX200 S6  
Operating Manual  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware installation  
4.5.1 Using cable ties  
As an option, you can secure the power cable using a cable tie to ensure that  
the insulated connector cannot be disconnected from the server accidentally.  
The cable tie is included in the accessories pack that is delivered together with  
the server.  
1
0
Figure 11: Using cable ties  
Ê
Ê
Thread the cable tie through the eye (1).  
Pull the cable tie tight to secure the power cable.  
The insulated connector cannot now be disconnected from the server  
accidentally.  
I
You can loosen the cable tie by opening the small locking lever (2).  
62  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
Hardware installation  
4.6  
Notes on connecting/disconnecting cables  
V
CAUTION!  
Always read the documentation supplied with the device you wish to  
connect.  
Never connect, or disconnect cables during a thunderstorm.  
Never pull on a cable when disconnecting it. Always take hold of the  
cable by the plug.  
Follow the sequence described below to connect or disconnect external  
devices to or from the server:  
Be sure to wait for 10 seconds or more after shutdown before turning the  
server on.  
Connecting cables  
Ê
Ê
Ê
Ê
Ê
Turn off all power and equipment switches.  
Disconnect all power plugs from the properly grounded power outlets.  
Connect all cables to the server and peripherals.  
Plug all data communication cables into the utility sockets.  
Plug all power cords into the properly grounded power outlets.  
Disconnecting cables  
Ê
Ê
Ê
Ê
Turn off all power and equipment switches.  
Disconnect all power plugs from the properly grounded power outlets.  
Unplug all data communication cables from the utility sockets.  
Disconnect the relevant cables from the server and all the peripherals.  
TX200 S6  
Operating Manual  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Hardware installation  
64  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
5
Starting up and operation  
V
CAUTION!  
Follow the safety instructions in chapter "Important information" on  
5.1  
Access to the drives (floorstand model)  
5.1.1 Access to the accessible drives  
0
1
/
Figure 12: Removing the drive cover and snapping it into the hard disk drive cover  
Ê
Ê
Ê
Unlock the server (1).  
Remove the drive cover (2).  
Place the drive cover on the hard disk cover (3).  
I
Please note the following when operating with tape drives:  
If the system is programmed to eject the media automatically, the  
accessible drives must not be obstructed.  
The drive cover is replaced and the server locked in the reverse order.  
TX200 S6  
Operating Manual  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Starting up and operation  
Figure 13: Removing the drive cover from the hard disk drive cover  
Ê
Carefully pull out on the green release lever (1) and lift off the drive cover (2).  
66  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Starting up and operation  
5.1.2 Access to the HDD modules  
/
0
Figure 14: Removing the hard disk cover  
Ê
Ê
Unlock the server (1).  
Remove the hard disk cover (2).  
The hard disk drive cover is replaced and the server locked in the reverse order.  
TX200 S6  
Operating Manual  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Starting up and operation  
5.2  
Control elements and indicators  
5.2.1 Front of server  
4 6  
2
CSS  
RST  
5
3
0
1
+
ID  
NMI  
9
8
7
Figure 15: Front of server (example: rack model)  
1
2
3
4
5
3 x USB connectors  
ID indicator / ID button  
CSS indicator  
6
7
8
9
Power-on indicator / On/Off button  
Reset button  
NMI button  
Global Error indicator  
Hard disk activity indicator  
Optical drive activity indicator  
10 ID card  
68  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
                                 
Starting up and operation  
5.2.1.1 ID card  
You can pull out the ID card as far as it will go and push it back in again.  
The ID card contains various system information, such as the product name,  
serial number, order number, MAC addresses and DNS name.  
5.2.1.2 Control elements  
On/Off button  
When the system is switched off, it can be switched on again by  
pressing the On/Off button.  
When the system is operating, pressing the On/Off button will  
switch off the system.  
V
CAUTION!  
I Risk of loss of data!  
The On/Off button does not disconnect the server from the  
mains voltage. To disconnect from the mains completely,  
remove the power plug(s).  
NMI  
RST  
NMI button  
V
CAUTION!  
Do not press! Risk of loss of data! The NMI button may only  
be used by service.  
Reset button  
Pressing the reset button reboots the system.  
V
CAUTION!  
Risk of loss of data!  
ID  
ID button  
ID LED lights up (blue) on the front and on the rear of the server  
when the ID button is pressed. Both ID indicators are  
synchronized.  
TX200 S6  
Operating Manual  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Starting up and operation  
5.2.1.3 LEDs on the control panel  
Power indicator (two-color)  
Glows green when the server is switched on.  
Lights up orange when the server is switched OFF, but mains  
voltage is present (standby mode).  
Hard disk activity indicator (green)  
Lights up green when an internal hard disk drive is accessed.  
Global Error indicator (orange)  
!
Lights up orange if a prefailure event has been detected that  
requires (precautionary) service intervention.  
Flashes orange if an error was detected that requires service  
intervention.  
Does not light up if there is no critical event.  
If the event is still acute after a power failure, the indicator is  
activated after the restart.  
The indicator also lights up in standby mode.  
You can find more details on the indicated errors in the System  
Event Log (SEL), on the ServerView Local Service Panel, on the  
ServerView Local Service Display, in the ServerView Operations  
Manager or via the iRMC S2's Web interface.  
70  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
       
Starting up and operation  
CSS  
CSS indicator (yellow)  
Lights up yellow if a prefailure event was detected for a CSS  
component that you can fix yourself (for reasons of precaution)  
with the CSS concept.  
Flashes yellow if an error was detected that you can fix yourself  
with the CSS concept.  
Does not light up when the system is OK.  
If the event is still acute after a power failure, the indicator is  
activated after the restart.  
The indicator also lights up in standby mode.  
For more information on the CSS concept, see "Customer Self  
ID  
ID indicator (blue)  
Lights up blue when the system has been selected by pressing the  
ID button. To deactivate, press the button again.  
The ID indicator can also be activated via the ServerView  
Operations Manager and the iRMC S2 Web interface and its  
status reported to the ServerView Operations Manager and the  
iRMC S2.  
5.2.1.4 Indicators on the drives  
DVD drive activity indicator  
Lights up green when the storage medium is being accessed.  
TX200 S6  
Operating Manual  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Starting up and operation  
Hard disk drive indicators  
1
2
1
2
Figure 16: Indicators on the 3.5 inch and 2.5 inch HDD modules  
1 HDD BUSY (green)  
Lit: HDD in active phase (drive active, drive being accessed)  
Does not light: HDD inactive  
2 HDD FAULT (orange)  
(in conjunction with a RAID controller)  
SAS server variant  
Does not light: no HDD error  
Lit: HDD Faulty (drive defective/needs replacing, drive failed, drive  
deactivated by software or the HDD module is not correctly inserted)  
Slow flashing: HDD Rebuild (the data is being restored after  
changing a drive)  
Fast flashing: HDD Identify  
SATA server variant  
Does not light: no HDD error  
Lit: HDD Faulty or Rebuild Stopped (drive defective and must be  
replaced, a rebuild process was stopped or the module is not  
correctly inserted)  
Slow flashing: HDD Rebuild (the data is being restored after  
changing a drive)  
Fast flashing: HDD Identify  
72  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
Starting up and operation  
5.2.2 Rear of server  
5.2.2.1 Indicators on the connector panel  
CSS, Global Error and ID indicators  
/
Figure 17: Indicators on the connector panel: CSS, Global Error and ID indicators  
1
CSS, Global Error and ID indicators (yellow, orange and blue)  
Global Error indicator (orange)  
Lights up orange if a prefailure event has been detected that  
requires (precautionary) service intervention.  
Flashes orange if an error was detected that requires service  
intervention.  
!
Does not light up if there is no critical event.  
If the event is still acute after a power failure, the indicator is  
activated after the restart.  
The indicator also lights up in standby mode.  
You can find more details on the indicated errors in the System  
Event Log (SEL), on the ServerView Local Service Panel, on the  
ServerView Local Service Display, in the ServerView Operations  
Manager or via the iRMC S2's Web interface.  
TX200 S6  
Operating Manual  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Starting up and operation  
CSS  
CSS indicator (yellow)  
Lights up yellow if a prefailure event was detected for a CSS  
component that you can fix yourself (for reasons of precaution)  
with the CSS concept.  
Flashes yellow if an error was detected that you can fix yourself  
with the CSS concept.  
Does not light up when the system is OK.  
If the event is still acute after a power failure, the indicator is  
activated after the restart.  
The indicator also lights up in standby mode.  
For more information on the CSS concept, see "Customer Self  
ID  
ID indicator (blue)  
Lights up blue when the system has been selected by pressing the  
ID button. To deactivate, press the button again.  
The ID indicator can also be activated via the ServerView  
Operations Manager and the iRMC S2 Web interface and its  
status reported to the ServerView Operations Manager and the  
iRMC S2.  
74  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
Starting up and operation  
LAN indicators  
/ 01 2  
Figure 18: Indicators on the connector panel: LAN indicators  
1
LAN activity indicator (management LAN)  
Lights up green if a LAN connection exists.  
Does not light up if no LAN connection exists.  
Flashes green when a LAN transfer is in progress.  
2
3
LAN transfer rate indicator (management LAN)  
Lights up green for a LAN transfer rate of 100 Mbit/s.  
Does not light up for a LAN transfer rate of 10 Mbit/s.  
LAN activity indicator (shared LAN)  
Lights up green if a LAN connection exists.  
Does not light up if no LAN connection exists.  
Flashes green when a LAN transfer is in progress.  
4
LAN transfer rate indicator (shared LAN)  
Lights yellow for a LAN transfer rate of 1 Gbit/s.  
Lights up green for a LAN transfer rate of 100 Mbit/s.  
Does not light up for a LAN transfer rate of 10 Mbit/s.  
I
Depending on the settings in the BIOS, the shared LAN connector may  
also be used as a management LAN connector. You will find further  
information in the "D2799 BIOS Setup Utility for PRIMERGY TX200 S6"  
manual.  
TX200 S6  
Operating Manual  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Starting up and operation  
5.2.2.2 Indicators on the hot-plug power supply unit  
/
/
Figure 19: Indicators on the hot-plug power supply units  
1
Indicator on hot-plug power supply unit (two colors)  
Flashes green when the server is switched off, but mains voltage is  
present (standby mode).  
Lights up green when the server is switched on and functioning  
properly.  
Lights up orange if the power supply unit has failed.  
76  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
Starting up and operation  
5.3  
Switching the server on and off  
V
CAUTION!  
It nothing appears on the screen but flickering stripes after switching on  
the server, switch the server off immediately (see chapter  
The On/Off button does not disconnect the server from the mains  
voltage. To completely disconnect it from the mains voltage, remove the  
power plug(s) from the socket(s).  
Switching the server on  
The power-on indicator (see figure 15 on page 68) lights up orange (standby  
mode).  
Starting up for the first time:  
Ê
Ê
Ê
Press the On/Off button (see figure 15 on page 68).  
Insert ServerView Suite DVD 1 in the DVD drive.  
Follow the on-screen instructions (see also section "Configuring the  
System already installed:  
Ê
Press the On/Off button.  
The server is switched on, performs a system test and boots the  
operating system.  
I
Depending on the configurations, the boot process may be prolonged  
and the screen may remain dark for a while.  
Switching the server off  
Power-on indicator lights up green.  
Ê
Shut down the operating system properly.  
The server is switched off automatically and goes into standby mode. The  
power-on indicator lights up orange.  
TX200 S6  
Operating Manual  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Starting up and operation  
I
If the operating system does not switch the server off automatically, press  
the On/Off button for at least four seconds and/or send a control signal  
for power button override.  
Other On/Off options  
Besides the On/Off button, the server can be switched ON and OFF in the  
following ways:  
Timer-controlled switch-on/off  
Using the ServerView Operations Manager or iRMC S2, you can configure  
that the server is switched on/off controlled by timer.  
Ring indicator  
The server is switched on by an internal or external modem.  
Wake up On LAN (WOL)  
The server is switched on by a command via the LAN (Magic PacketTM).  
After power failure  
The server automatically reboots following a power failure (depending on the  
settings in the BIOS or in iRMC S2).  
Power button override  
The system can be switched off by pressing and holding down the On/Off  
button (for approximately 4 - 5 seconds).  
V
CAUTION!  
There is a risk that data may be lost.  
iRMC S2  
iRMC S2 offers various options for switching the server on and off, e.g. via  
the Power On Off page of the iRMC S2 Web interface.  
78  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
Starting up and operation  
5.4  
Configuring the server  
This section contains information about configuring the server and installing the  
operating system.  
I
Make sure that the power saving functions are disabled in the Power  
menu of the BIOS Setup during operation.  
5.4.1 Configuring the onboard SATA controller  
A 6-port SATA controller is integrated on the system board. You can configure  
the onboard SATA controller either before or during installation with the  
ServerView Installation Manager. Using the ServerView Installation Manager is  
recommended.  
I
The controller has its own configuration utility. For further information,  
refer to the "Embedded MegaRAID Software User’s Guide" (on the  
ServerView Suite DVD 2 under Industry Standard Servers - Expansion Cards  
I - Storage Adapters - LSI RAID / SCSI Controllers).  
Descriptions of operating systems not covered in the controller manual  
I are provided in the corresponding readme files on the driver CDs.  
To control SAS hard disk drives an additional SAS/SATA RAID controller  
is necessary (see the following section).  
5.4.2 Configuring the SAS/SATA RAID controller  
The server has a SAS/SATA RAID controller with "Integrated Mirroring  
Enhanced" functionality or "MegaRAID functionality". You can configure the  
SAS/SATA RAID controller either before or during installation with the  
ServerView Installation Manager. Using the ServerView Installation Manager is  
recommended.  
I
The controller makes a separate utility available for IME configuration.  
For further information, refer to the "Integrated RAID for SAS User’s  
Guide" (on the ServerView Suite DVD 2 under Industry Standard Servers -  
Expansion Cards - Storage Adapters - LSI RAID / SCSI Controllers).  
TX200 S6  
Operating Manual  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Starting up and operation  
A separate utility is available to the controller for MegaRAID  
configuration. For further information, refer to the "SAS Software User’s  
Guide" (on the ServerView Suite DVD 2 under Industry Standard Servers -  
Expansion Cards - Storage Adapters - LSI Configuration Software).  
Further information on modular RAID controllers is provided in the  
"Modular RAID Controller Installation Guide" (on the ServerView Suite  
DVD 2 under Industry Standard Servers - Expansion Cards - Storage Adapters  
I - LSI RAID / SCSI Controllers).  
Descriptions of operating systems not covered in the controller manual  
are provided in the corresponding readme files on the driver CDs.  
5.4.3 Configuring the server and installing the operating  
system with the ServerView Installation Manager  
Using the ServerView Installation Manager on the ServerView Suite DVD 1  
provided, you can conveniently configure the server and install the operating  
system. This includes configuring the server-specific settings using the  
ServerView Configuration Manager and configuring the RAID controller using  
the ServerView RAID Manager.  
Advantages of the ServerView Installation Manager  
Wizard assisted configuration of your server hardware and disk arrays  
Wizard assisted installation of all leading server operating systems  
Wizard-assisted creation of configuration files for unattended installation of  
several PRIMERGY servers with identical hardware configurations.  
Installation of drivers and additional software.  
I
The software that can be installed depends on your server’s hardware  
I configuration. This configuration is detected automatically.  
Descriptions of operating systems not covered in the RAID controller  
manual are provided in the corresponding readme files on the driver  
CDs.  
To find out how to operate the ServerView Installation Manager and for further  
information, refer to the associated manual.  
80  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
     
Starting up and operation  
If you are using the ServerView Installation Manager, you can skip the following  
section on how to configure the server and install the operating system.  
Continue from section "Cleaning the server" on page 82.  
5.4.4 Configuring the server and installing the operating  
system without the ServerView Installation  
Manager  
Configure onboard SATA controller  
Configure the controller as described in section "Configuring the onboard SATA  
Configure SAS/SATA RAID controller with "Integrated Mirroring  
Enhanced"  
Configure the controller as described in section "Configuring the onboard SATA  
Configure SAS/SATA RAID controller with "MegaRAID functionality"  
Configure the controller as described in section "Configuring the onboard SATA  
Installing the operating system  
Ê
Ê
Ê
Insert the CD/DVD for the operating system you want to install.  
Reboot the server.  
Follow the instructions on screen and in the manual for the operating  
system.  
TX200 S6  
Operating Manual  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Starting up and operation  
5.5  
Cleaning the server  
V
CAUTION!  
Switch the server off and disconnect the power plugs from the properly  
grounded power outlets.  
Do not clean any interior parts yourself; leave this job to a service  
technician.  
Do not use any cleaning agents that contain abrasives or may corrode  
plastic.  
Ensure that no liquid enters the system. Ensure that the ventilation areas  
of the server and the monitor are clear.  
Do not use any cleaning sprays (including flammable types). It may  
cause a device failure or a fire.  
Clean the keyboard and the mouse with a disinfecting cloth.  
Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a  
cloth that has been moistened in a mild domestic detergent and then carefully  
wrung out.  
82  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
     
6
Property and data protection  
The floorstand model is protected against unauthorized opening by a lock. Apart  
from this, the server is also fitted with an intrusion detection switch which  
enables the ServerView Operations Manager program to detect and log any  
removal of the side cover or top cover and the cover for the HDD modules.  
To prevent it being removed from its location, the floorstand model can be  
secured to a fixed object with a steel cable running through a clip on the back.  
The rack model is protected against unauthorized access by a lockable rack  
door.  
To protect the system and data internally against unauthorized access, you can  
activate the security functions of the BIOSSetup.  
6.1  
BIOS Setup security functions  
The Security menu in BIOS Setup offers various options for protecting your data  
from unauthorized access. By combining these options, you can also achieve  
optimum protection for your system.  
I
A detailed description of the Security menu and how to assign passwords  
can be found in the BIOS Setup documentation on the ServerView Suite  
DVD 2.  
TX200 S6  
Operating Manual  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Property and data protection  
84  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
7
Troubleshooting and tips  
V
CAUTION!  
Follow the safety instructions in the "Safety notes and other important  
information" manual and in chapter "Important information" on page 31.  
If a fault occurs, attempt to resolve it using the measures described:  
in this chapter,  
in the documentation for the connected devices,  
in the help systems of the software used.  
If you fail to correct the problem, proceed as follows:  
Ê
Make a list of the steps performed and the circumstances that led to the fault.  
Also make a list of any error messages that were displayed.  
Ê
Ê
Switch off the server.  
Contact our customer service team.  
7.1  
Power-on indicator remains unlit  
The power-on indicator remains dark after you switch on your device.  
Power cable incorrectly connected  
Ê
Make sure that the power cable(s) is/are correctly connected to the server  
and the grounded power outlet(s).  
Power supply overloaded  
Ê
Ê
Disconnect the server power plug(s) from the grounded power outlet(s).  
Wait a few seconds before you plug it/them into the grounded power outlet(s)  
again.  
Ê
Switch on your server.  
TX200 S6  
Operating Manual  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Troubleshooting and tips  
7.2  
Server switches itself off  
Server Management has detected an error  
Ê
Check the error list of System Event Log in ServerView Operations Manager  
or in the iRMC S2 web interface, and attempt to eliminate the error.  
7.3  
Screen remains blank  
Monitor is switched off  
Switch on your monitor.  
Ê
Screen has gone blank  
Ê
Press any key on the keyboard.  
or  
Ê
Deactivate screen saver. Enter the appropriate password.  
Brightness control is set to dark  
Ê
Set the brightness control on the monitor to light. For detailed information,  
refer to the operating manual supplied with your monitor.  
Power cable or monitor cable not connected  
Ê
Ê
Switch off the monitor and the server.  
Check whether the power cable is properly connected to the monitor and to  
the grounded power outlet.  
Ê
Check whether the monitor cable is properly connected to the server and  
monitor (if it is plugged in with a connector). If a separate graphics card is  
installed in the server, then the monitor cable must be connected to the  
graphics card.  
Ê
Switch on the monitor and the server.  
86  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
       
Troubleshooting and tips  
7.4  
Flickering stripes on monitor screen  
V
CAUTION!  
Switch off the server immediately. Risk of damaging the server.  
Monitor does not support the set horizontal frequency  
Ê
Find out which horizontal frequency your monitor screen supports. You will  
find the horizontal frequency (also known as line frequency or horizontal  
deflection frequency) in the documentation for your monitor.  
Ê
Refer to the documentation for your operating system or the software for the  
screen controller for details of how to set the correct horizontal frequency for  
your monitor, and follow the procedure accordingly.  
7.5  
No screen display or display drifts  
The wrong horizontal frequency or resolution has been selected for the  
monitor or for the application program.  
Ê
Find out which horizontal frequency your monitor screen supports. You will  
find the horizontal frequency (also known as line frequency or horizontal  
deflection frequency) in the documentation for your monitor.  
Ê
Refer to the documentation for your operating system or the software for the  
screen controller for details of how to set the correct horizontal frequency for  
your monitor, and follow the procedure accordingly.  
TX200 S6  
Operating Manual  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Troubleshooting and tips  
7.6  
Incorrect date and time  
Ê
Set the date and time in the operating system or in the BIOS Setup under  
the Main menu, using System Date and System Time respectively.  
I
Note that the operating system may affect the system time. For example,  
the operating system time may deviate from the system time under Linux,  
and would overwrite the system time in the default setting on shutdown.  
If the date and time are still wrong after the server has been switched off and  
back on again, replace the lithium battery (for a description refer to the Technical  
Manual for the D2799 system board) or contact our customer service team.  
7.7  
Drives reported as "dead" when starting  
system  
RAID controller configuration incorrect  
Check and correct the settings for the drives using the RAID controller utility.  
Further information is provided in the manual for the RAID controller.  
Ê
88  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
       
Troubleshooting and tips  
7.8  
Added drive reported as defective  
RAID controller is not configured for this drive  
The drive was probably installed when the system was switched off.  
Ê
Reconfigure the RAID controller for the drive using the corresponding utility.  
Information is provided in the documentation for the RAID controller.  
or  
Ê
Remove and reinstall the drive while the system is switched ON.  
If the hard disk drive continues to be shown as defective, then replace it (see  
7.9  
Error message on screen  
The meaning of the error message is explained in the documentation for the  
relevant components and programs on the ServerView Suite DVD 2.  
TX200 S6  
Operating Manual  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
CSS components  
This chapter describes how to handle CSS components and how to identify  
defective CSS components and replace them yourself.  
I
Further information on the CSS concept is provided in the "ServerView  
Suite Local Service Concept - LSC" manual on the ServerView Suite  
V DVD 2.  
CAUTION!  
Follow the safety instructions in the chapter "Important information" on  
In the PRIMERGY TX200 S6 server, the following components are considered  
to be CSS components:  
Hot-plug components  
Hot-plug power supply units  
Hot-plug hard disk drives  
You can expand or replace the hot-plug components during operation.  
Non-hot-plug components  
Memory modules  
System fan  
Expansion cards  
These components can be changed by you in the event of an error.  
Expansions and upgrades may only be carried out by authorized specialist  
personnel. These operations are described in the "Options Guide".  
TX200 S6  
Operating Manual  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CSS components  
8.1  
Hot-plug components  
This section describes how to handle hot-plug components and how to modify  
your server hardware (e.g. adding/replacing hot-plug power supply units or hot-  
plug HDD modules).  
The hot-plug procedure increases the availability of system operation and  
guarantees a high degree of data integrity and failsafe performance.  
8.1.1 Hot-plug power supply units (optional)  
With two hot-plug power supply units installed, if a defect occurs in one power  
supply unit, the other power supply unit ensures unimpaired further operation.  
The defective power supply unit can be replaced without interrupting operation.  
8.1.1.1 Replacing the hot-plug power supply unit  
0
/
Figure 20: Unlocking and removing the power supply unit  
V
CAUTION!  
When replacing a non-defective hot-plug power supply unit in a non-  
redundant configuration (only one power supply unit), the server must  
be switched off first.  
92  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
           
CSS components  
Ê
Ê
Remove the power cable from the installed power supply unit.  
Push the green catch in the direction of the arrow (1) while pulling the power  
supply unit out of its mounting location (2) by the handle.  
Ê
Slide the new power supply unit into the empty slot until the locking  
mechanism engages.  
I
Make sure that the power supply unit engages correctly in the slot and  
is locked in position.  
This is the only way to prevent the power supply unit from sliding out  
of its mountings and being damaged during transportation.  
Ê
Connect the newly installed power supply unit.  
8.1.2 Hot-plug hard disk drives  
The hard disk drives which can be ordered for the PRIMERGY TX200 S6 are  
supplied already mounted in an installation frame so that defective hard disk  
drives can be replaced and new hard disk drives can be added during operation.  
The hard disk drive and installation frame together make up the HDD module.  
V
CAUTION!  
The hard disk drive must not be removed from the installation frame  
by anyone except a service technician.  
The HDD modules (drives) must all be marked clearly so that they  
can be put back in their original places after an upgrade. If this is not  
done, existing data can be lost.  
The hot-plug function is only possible in conjunction with a  
corresponding RAID configuration.  
Further information about the RAID configuration or RAID level can  
be found in the RAID controller documentation.  
Do not touch the circuitry on boards or soldered parts. Hold the  
metallic areas or the edges of the circuit boards.  
Before removing the unit, turn the power off and wait for about 30  
seconds until the disk stops spinning completely.  
When the hard disk unit is starting up, you may hear a resonant noise  
for a while, but this does not mean a failure.  
TX200 S6  
Operating Manual  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CSS components  
Depending on the OS, you can configure the write cache settings for  
the hard disk drives. However, disable the write cache for use in this  
server. If the power failure should occur while the write cache is  
enabled, cached data may be lost.  
When disposing of, transferring, or returning a hard disk unit, wipe out  
the data on the drive for your own security.  
Rough handling of hard disk units can damage the stored data. To  
cope with any unexpected problems, always back up important data.  
When backing up data to another hard disk drive, you should make  
backups on a file or partition basis.  
Be careful not to hit the hard disk unit or bring it into contact with  
metallic objects.  
Use the device on a shock and vibration free surface.  
Do not use the unit in extremely hot or cold locations, or locations with  
extreme temperature changes.  
Never attempt to disassemble the hard disk unit.  
94  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
CSS components  
8.1.2.1 3.5-inch HDD module and dummy module  
/
0
0
1
2
3
4
5
Figure 21: 3.5-inch HDD module and dummy module  
1
2
3
4
Dummy module  
Tabs for unlocking the dummy module  
HDD module (installation frame with hard disk drive installed)  
Indicators  
HDD Busy (LED green)  
HDD Fault (LED orange)  
5
6
7
Handle for locking and unlocking the HDD module  
Button for locking and unlocking the handle  
Ridge for applying a sticker with the current drive name and drive size  
TX200 S6  
Operating Manual  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CSS components  
8.1.2.2 2.5-inch HDD module and dummy module  
/
0
0
1
23 4  
5
Figure 22: 2.5-inch HDD module and dummy module  
1
2
3
4
Dummy module  
Tabs for unlocking the dummy module  
HDD module (installation frame with hard disk drive installed)  
Indicators  
HDD Busy (LED green)  
HDD Fault (LED orange)  
Handle for locking and unlocking the HDD module  
Button for locking and unlocking the handle  
5
6
7
Ridge for applying a sticker with the current drive name and drive size  
96  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
CSS components  
8.1.2.3 Handling hard disk drives and HDD modules  
Hard disk drives incorporated in the HDD modules are highly sensitive  
electromagnetic devices and must be handled with great care. Incorrect  
handling can cause partial or total failure of the hard disk drives. These failures  
can result in data errors and to a loss of data or to total corruption of the hard  
disk drive.  
Observe the following rules to prevent such problems occurring:  
Only store and transport HDD modules within the limits stipulated in the  
specification.  
When transporting HDD modules (even over short distances), always use  
the original packaging (ESD label).  
Never expose HDD modules to a temperature shock. Avoid the formation of  
condensation inside and on the outside of the hard disk drive.  
V
CAUTION!  
The HDD module must be acclimatized in its operating environment  
for an acclimatization time before it is started up for the first time.  
Temperature difference (°C) Minimum acclimatization time  
(operating environment/  
outside)  
(hours)  
5
3
5
10  
15  
7
20  
8
25  
9
30  
10  
Table 2: Acclimatization times for HDD modules  
Always set the HDD module down carefully, with the large surface facing  
downwards to prevent it from tipping over.  
TX200 S6  
Operating Manual  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CSS components  
8.1.2.4 Floorstand: removing the hard disk cover  
For a floorstand server you make the HDD modules accessible by removing the  
hard disk cover:  
/
0
Figure 23: Removing the hard disk cover  
Ê
Ê
Unlock the server (1).  
Remove the hard disk cover (2).  
The hard disk drive cover is replaced and the server locked in the reverse order.  
98  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
CSS components  
8.1.2.5 Removing/installing the dummy module  
Free slots are provided with dummy modules. Remove the dummy module  
before installing an additional HDD module.  
1
1
2
Figure 24: Removing/installing the dummy module (example: 3.5-inch dummy module)  
Ê
Press both tabs on the dummy module together until the locking mechanism  
disengages (1).  
Ê
Pull the dummy module out of the slot (2).  
To install a dummy module, follow the same procedure in reverse order.  
V
CAUTION!  
Keep the dummy module for future use. If you have removed a HDD  
module and do not install a new one in its place, put the dummy module  
back in its place for cooling, to comply with EMC regulations (regulations  
regarding electromagnetic compatibility), and for protection against fire.  
Ensure that the dummy module engages correctly in the bay.  
TX200 S6  
Operating Manual  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CSS components  
8.1.2.6 Installing the HDD module  
Unlocking the HDD module  
1
1
2
2
Figure 25: Unlocking the 3.5-inch and 2.5-inch HDD modules  
Ê
Ê
Release the locking mechanism by pressing the locking button (1).  
Push the handle of the HDD module fully in the direction of the arrow (2).  
The HDD module is now unlocked.  
100  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
     
CSS components  
Installing the HDD module  
/
0
/
0
Figure 26: Installing the 3.5-inch and 2.5-inch HDD modules  
Ê
Unlock the HDD module as described in section "Unlocking the HDD  
Ê
Ê
Carefully push the HDD module into the empty slot (1) until it stops.  
Push the handle of the HDD module as far as it will go in the direction of the  
arrow (2) until the locking mechanism is engaged.  
TX200 S6  
Operating Manual  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CSS components  
8.1.2.7 Removing the HDD module  
V
CAUTION!  
Only remove a HDD module during operation if the drive is not  
currently being accessed. Observe the control LEDs for the  
corresponding HDD modules (see "Hard disk drive indicators" on  
page 72).  
Under no circumstances should you remove a HDD module while the  
system is in operation if you are not sure that the hard disk drive is  
operated by a RAID controller and belongs to a disk array that is  
operating in RAID level 1, 5 or 6.  
A HDD module can only be replaced during operation in conjunction  
with a corresponding RAID configuration.  
All HDD modules (drives) must be uniquely identified so that they can  
be reinstalled in their original mounting locations later. If this is not  
done, existing data can be lost.  
If you want to remove a HDD module during operation, proceed as follows:  
Ê
If you want to remove a HDD module that is not defective, the drive must be  
first set to "Offline" via the software (RAID controller configuration software).  
Ê
Unlock the HDD module as described in section "Unlocking the HDD  
Ê
Ê
Pull the HDD module out a few centimeters.  
Wait for at least 60 seconds.  
I
This period is necessary for the RAID controller to recognize that a  
HDD module has been removed and for the hard disk drive to come  
to a stop.  
Ê
Pull the HDD module out completely.  
102  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
 
CSS components  
Ê
Install the new HDD module, as described in "Installing the HDD module" on  
V
CAUTION!  
If you have removed a HDD module and do not install a new one in  
its place, put the dummy module back in its place for cooling, to  
comply with EMC regulations (regulations regarding electromagnetic  
compatibility), and for protection against fire. Ensure that the dummy  
module engages correctly in the bay.  
8.2  
Non-hot-plug components  
If a defective non-hot-plug component is detected (for more information, see  
chapter "Starting up and operation" on page 65 and the "ServerViewSuite Local  
Service Concept - LSC" manual on the ServerView Suite DVD 2), proceed as  
follows:  
Ê
Exit all applications and shut down the server properly (see section  
Ê
Ê
Pull all power connectors out of the power outlets.  
If the model is a rack model, remove the server from the rack (see section  
table, for example.  
Ê
Ê
Open the server (see section "Opening the server" on page 104).  
Press the Indicate CSS button on the system board (see the technical  
manual for the system board D2799).  
The PRIMERGY Diagnostic LED of the defective CSS component lights up  
orange, thereby indicating which CSS component (memory module, fan or  
expansion card) on the system board must be replaced (see technical  
manual for the system board D2799).  
TX200 S6  
Operating Manual  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CSS components  
8.2.1 Opening the server and identifying the defective  
CSS component  
8.2.1.1 Opening the server  
V
CAUTION!  
The device can be seriously damaged if it is opened without  
authorization or if repairs are attempted by untrained personnel.  
It is essential to observe the safety instructions in chapter "Important  
1
0
/
Figure 27: Opening the server (example: floorstand model)  
Ê
Ê
Unlock the server.  
Pull the locking lever as far as it will go (1).  
This pushes the side cover backward (2).  
Remove the side cover (3).  
Ê
104  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
     
CSS components  
8.2.1.2 Removing system fan 2 (and 4)  
Figure 28: System fan 2 and system fan 2&4  
The standard system fan 2 has just one fan cable; the redundant system  
fan 2&4 (double fan) has two fan cables (as two fans are integrated internally).  
The procedure for installing and removing both system fans is identical except  
for connecting the fan cables.  
Figure 29: Example: Removing system fan 2&4  
TX200 S6  
Operating Manual  
105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CSS components  
Ê
Disconnect the fan cable from the connector FAN2 (if there is a second fan  
cable, disconnect this from FAN4) on the system board (see the technical  
manual for the system board D2799).  
Ê
Ê
Ê
Press the two green locks of the air duct together (1).  
Press the green lock of the air duct in the direction of the arrow (2).  
Lift the air duct with the integrated system fan 2 (and 4) up and out (3).  
8.2.1.3 Removing system fan 1 (and 3)  
Ê
Remove system fan 2 (and 4) (see "Removing system fan 2 (and 4)" on  
Figure 30: System fan 1 and system fan 1&3  
The standard system fan 1 is shorter and has just one fan cable; the redundant  
system fan 1&3 is taller (as 2 fans are integrated internally) and has two fan  
cables.  
The procedure for installing and removing both system fans is identical except  
for connecting the fan cables.  
106  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
CSS components  
Figure 31: Example: Removing system fan 1&3  
Ê
Disconnect the fan cable from the connector FAN1 on the system board (if  
there is a second fan cable, disconnect this from FAN3).  
Ê
Ê
Push the locking lever in the direction of the arrow (1).  
Pull system fan 1 (and 3) in the direction of the arrow (2) to disengage the  
four hooks.  
Ê
Take system fan 1 (and 3) out (3).  
8.2.1.4 Identifying a CSS component  
Ê
Press the Indicate CSS button on the system board (see the technical  
manual for the system board D2799).  
The PRIMERGY Diagnostic LED of the defective CSS component lights up  
orange, thereby indicating which CSS component (memory module, fan or  
expansion card) on the system board must be replaced (see technical  
manual for the system board D2799).  
TX200 S6  
Operating Manual  
107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CSS components  
8.2.2 Replacing a memory module  
8.2.2.1 Removing a defective memory module  
2
1
1
Figure 32: Removing a memory module  
Ê
Ê
Press the securing clips on both sides of the memory slot concerned  
outward. (1).  
Pull the defective memory module out of the slot (2).  
8.2.2.2 Installing a new memory module  
V
CAUTION!  
Please note the equipping rules in the technical manual for the system  
board D2799.  
1
2
2
Figure 33: Inserting a memory module  
Ê
Carefully press the memory module into the slot (1) until the securing clips  
on both sides of it engage (2).  
108  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
           
CSS components  
8.2.3 Replacing the system fan  
V
CAUTION!  
Since the standard system fans 1 and 2 are not redundant, these system  
fans have to be replaced immediately.  
If one of the four redundant system fans (1&3 and 2&4) fails, one of the  
two predetermined fans (system fan 3 and 4) increases its power to  
ensure that the server is cooled properly. The redundant system fans  
should be replaced as soon as possible.  
8.2.3.1 Replacing system fan 2 (and 4)  
Ê
Remove the defective system fan 2 (and 4) (see "Removing system  
Ê
Install the new system fan 2 (and 4) (see "Installing system fan 2 (and 4)" on  
8.2.3.2 Replacing system fan 1 (and 3)  
Ê
Remove the defective system fan 1 (and 3) (see "Removing system fan 1  
Ê
Install the new system fan 1 (and 3) (see "Installing system fan 1 (and 3)" on  
TX200 S6  
Operating Manual  
109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CSS components  
8.2.4 Replacing an expansion card  
8.2.4.1 Removing a defective expansion card  
Figure 34: Removing a defective expansion card  
Ê
Ê
Ê
Ê
If necessary, remove the cables from the defective expansion card.  
Push the lever upwards (1).  
Press onto the clip and remove it.  
Pull the defective expansion card out of its slot (2).  
110  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
       
CSS components  
8.2.4.2 Installing a new expansion card  
Figure 35: Installing a new expansion card  
Ê
Carefully press the new expansion card into the slot until it clicks into  
place (1).  
Make sure that the lug on the slot cover clicks into place in the  
corresponding hole.  
Ê
Ê
Ê
Ê
Fit the clip onto the slot cover so that the pin fits into the hole.  
Push the clip under the metal nose until it clicks into place.  
Swing the lever (2) downwards into its locking position.  
If necessary, connect the cables to the expansion card.  
TX200 S6  
Operating Manual  
111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CSS components  
8.2.5 Reinstalling the fans and closing the server  
8.2.5.1 Installing system fan 1 (and 3)  
Figure 36: Installing system fan 1 (and 3)  
Ê
Ê
Ê
Place the hooks of system fan 1 (and 3) into the recesses on the rear of the  
server (1).  
Push system fan 1 (and 3) in the direction of the arrow until the locking lever  
engages (2).  
Connect the fan cable to the connector FAN1 (if there is a second fan cable,  
connect this in FAN3) on the system board (see the technical manual for the  
system board D2799).  
112  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
     
CSS components  
8.2.5.2 Installing system fan 2 (and 4)  
Ê
Connect the fan cable to the connector FAN2 (if there is a second fan cable,  
connect this in FAN4) on the system board (see the technical manual for the  
system board D2799).  
Figure 37: Installing system fan 2 (and 4)  
Ê
Carefully insert the air duct with the integrated system fan 2 (and 4) (1).  
Make sure that the locks (2) of the air duct engage in the housing bracket  
and in the recess of the fixing plate (standard power supply) or the power  
supply cage (redundant power supply).  
TX200 S6  
Operating Manual  
113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CSS components  
8.2.5.3 Closing the server  
/
0
0
Figure 38: Closing the server (example: floorstand model)  
Ê
Ê
Pull the locking lever as far as it will go and insert the side cover in the five  
recesses (see small arrows) of the housing (1).  
Press the side cover against the housing and at the same time push the  
locking lever shut (2).  
Closing the locking lever pushes the side cover forwards and the hooks on  
the upper edge of the side cover engage.  
Ê
In the case of rack models, you still have to slide the server back into the rack  
Ê
Ê
Connect all power plugs to the power outlets.  
Press the On/Off button to start up the server.  
114  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
   
9
Appendix: server specification  
This section explains the specifications for the server. The specifications for this  
server are liable to be updated without any notice. Please be forewarned.  
System Board  
System board type  
Chipset  
D2799  
Intel 5500  
Processor  
Processor quantity and 1or 2 Intel Xeon processors  
type  
Memory Modules Configuration  
Memory slots  
12  
Memory slot type  
DIMM (DDR3)  
2 GB - 96 GB  
Memory capacity  
(min. - max.)  
Memory protection  
Advanced ECC; Memory Scrubbing; SDDC  
(Chipkill™); Hot-spare memory support  
Memory Mirroring support  
Memory notes  
max. 96 GB registered; min. 2 GB unbuffered;  
Memory Mirroring with 2 identical modules, Hot-  
spare Memory with three identical modules per  
channel  
Interfaces  
USB connectors  
10 x USB 2.0 (3x front, 4x rear, 3x internal for backup  
devices plus 1x USB stick)  
Graphics (15-pin)  
Serial 1 (9-pin)  
1 x VGA  
1 x serial RS-232-C, usable for iRMC S2 or system  
or shared  
TX200 S6  
Operating Manual  
115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix: server specification  
Serial 2 (9-pin)  
1 x serial RS-232-C, optional - occupies an unused  
slot  
LAN / Ethernet (RJ-45) 1 x Gbit/s Ethernet  
Service LAN (RJ45) 1 x dedicated service LAN connector for iRMC S2  
(10/100 Mbit/s) Service LAN traffic can be switched  
to shared onboard Gbit LAN port  
Onboard or integrated controllers  
RAID Controller Modular RAID 0/1 controller with "Integrated  
Mirroring Enhanced" (SAS IME) for SAS1.0.  
RAID levels 0, 1 and 1E are supported for internal  
hard disk drive configurations. For the Japanese  
market only RAID level 1 is supported for internal  
hard disk drive configurations.  
Modular RAID 0/1 controller with “MegaRAID  
functionality” (SAS MegaRAID) for SAS1.0 and  
SAS2.0. RAID levels 0, 1,10 and 1E are supported  
for internal hard disk drive configurations.  
Modular RAID 5/6 controller with "MegaRAID  
functionality" (SAS MegaRAID) for SAS1.0 and  
SAS2.0. RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are  
supported for internal hard disk drive configurations.  
SATA Controller  
ICH10R, 6-port SATA (4x for internal hard disks, 2x  
for accessible drives)  
SATA Controller type  
notes  
On board SATA controller supports RAID levels  
0,1,10  
Remote Management Integrated Remote Management Controller  
Controller  
(iRMC S2, 32 MB attached memory incl. graphics  
controller), IPMI 2.0 compatible  
Trusted Platform  
Module (TPM)  
Infineon TCG V1.2 compliant (option)  
116  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Appendix: server specification  
PCI-Slots  
PCI-Express 2.0 x4  
(mech. x8)  
2 x full height (1x long, 1x short)  
PCI-Express 2.0 x8  
2 x full height (1x notched, thus usable for x16 cards  
operating in x8 mode)  
PCI-Express x4 (mech. 1 x full height  
x8)  
PCI  
1 x  
Slot notes  
PCI slot: 32-bit / 33 MHz, 5 V; in SAS-configurations  
1x PCI-Express slot is occupied by the modular  
RAID-Controller  
Drive bays  
Hard disk bay  
configuration  
4x 3,5-inch, for SAS / SATA or 8x 2,5-inch for  
SAS/SATA/SSD optional  
Accessible drive bays 3 x 5.25/1.6-inch  
Notes accessible drives all possible options described in relevant system  
configurator  
Operating Panel  
Operating buttons  
On/off switch  
NMI button  
Reset button  
Status LEDs  
System status (orange / yellow)  
Identification (blue)  
Hard disks access (green)  
Power (orange / green)  
Status LED at system System status (orange / yellow)  
rear side:  
Identification (blue)  
LAN connection (green)  
LAN speed (green / yellow)  
TX200 S6  
Operating Manual  
117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix: server specification  
Service displays  
(optional):  
ServerView Local Service Panel (LSP)  
ServerView Local Service Display (LSD)  
Weight  
Weight  
up to 36.8 kg  
Weight notes  
Rack mounting kit  
Weight may vary depending on actual configuration  
Rack mounting kit as option; for the Japanese  
market, the reack mounting kit is standard  
Dimensions (Base unit specific)  
Floor-stand (W x D x H) 205 (306) x 584 x 444 mm  
Rack (W x D x H)  
482 x 570 x 220mm  
Mounting Depth Rack 596 mm  
Dimension notes  
Floorstand width 306 mm with tilt protection; depth  
measured excludes handles on redundant PSU.  
Rack depth excludes handles of redundant PSU and  
rack front.  
Environmental  
Noise emission  
Measured according to ISO 7779 and declared  
according to ISO9296  
Sound pressure  
(LpAm)  
34 dB(A) (idle) / 36 dB(A) (operating)  
5.2 B (idle) / 5.7 B (operating)  
10 - 35°C  
Sound power (LWAd;  
1B = 10dB)  
Operating ambient  
temperature  
Operating relative  
humidity  
10 - 85 % (non condensing)  
118  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Appendix: server specification  
Electrical values  
Power supply  
configuration  
1x standard, 1x hot-plug or 2x redundant  
685 W  
Max. output of single  
power supply  
Standard power supply 700 W  
output  
Hot-plug power supply 800 W  
output  
Rated voltage range  
100 - 240 V  
Rated frequency range 47- 63 Hz  
Rated current  
max. 9.5 A – 4.0 A (100 V / 240 V)  
TX200 S6  
Operating Manual  
119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix: server specification  
120  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Index  
USB connector 59  
video connector 59  
consumables 43  
control elements 68  
control panel 68  
correcting faults 85  
CSS indicator 68, 71, 74  
3rd party rack  
installing in 57  
requirements 50  
A
acclimatization time 45, 97  
Advanced Video Redirection 21  
ambient conditions 27  
ASR&R 20  
D
data manipulation 11  
data protection 83  
data security 20  
DataCenter rack  
installing server 52  
requirements 49  
date, incorrect 88  
delivery note 29, 46  
devices, connecting to server 59  
disconnecting cables 63  
disposal, devices 44  
drive  
availability 20  
AVR 21  
B
batteries 35  
BIOS  
security functions 83  
BIOS update 23  
C
cables  
connecting 63  
disconnecting 63  
CE marking 26, 40  
Class A Compliance Statement 40  
cleaning  
“dead” 88  
defective 89  
indicators 71  
dummy module, HDD module 99,  
keyboard 82  
monitor 82  
mouse 82  
server 82  
DVD drive activity  
indicator 68  
DVD drive activity indicator 71  
closing, server 114  
components  
E
ECC 20  
EDC 20  
hardware 11  
software 11  
electrical data 26  
electromagnetic compatibility 26, 40  
electrostatic-sensitive devices  
(ESD) 38  
EMC directive 26  
EMC regulations 99, 103  
ENERGY STAR 39  
environment class 27  
configuration, server 79  
connecting cables 63  
Connecting the monitor 60  
connectors 59, 68  
COM1 59  
LAN connector 59  
management LAN connector 59  
TX200 S6  
Operating Manual  
121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
environmental protection 43  
error  
installation frame 93  
hard disk drive indicators 72  
HDD module 93  
drifting display on monitor 87  
drive “dead” 88  
drive defective 89  
incorrect date 88  
acclimatization time 97  
installation frame 100  
installing 100  
incorrect time 88  
hot-plug HDD module 93  
hot-plug power supply unit 60  
hot-spare memory, memory  
module 20  
no display on monitor 87  
power-on indicator does not  
light 85  
screen remains blank 86  
screen shows flickering  
stripes 87  
I
ID button 68, 69  
ID card 68, 69  
product name 46, 69  
serial number 46, 69  
ID indicator 68, 71, 74  
server switches itself off 86  
Error Correcting Code 20  
Error Detection Code 20  
error message on screen 89  
expansion card  
indicators  
installing 111  
replacing 110  
DVD drive activity 68, 71  
Global Error 68, 70, 73  
hard disk activity 68, 70  
hard disk drive 72  
ID 68, 71, 74  
expansion card, removing 110  
F
fault  
drifting display on monitor 87  
drive defective 89  
incorrect date 88  
incorrect time 88  
no display on monitor 87  
screen remains blank 86  
screen shows flickering  
stripes 87  
LAN activity 75  
LAN transfer rate 75  
on power supply unit 76  
on server 68  
operation 68  
system error 70, 73  
information, additional 13  
installing in  
FCC statement 40  
features 14  
flash EPROM 23  
3rd party rack 57  
DataCenter rack 52  
PRIMECENTER rack 52  
installing in the rack, notes 42  
Installing the operating system 81  
installing, server 49  
Integrated Mirroring Enhanced 17,  
G
Global Error indicator 68, 70, 73  
H
hard disk activity indicator 68, 70  
hard disk drive  
integrated Remote Management  
Controller 21  
iRMC S2 21  
handling 97  
hot-plug 93  
122  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Index  
L
power supply unit  
cable clamp 62  
labels 44  
LAN activity indicator 75  
LAN transfer rate, indicator 75  
laser information 37  
light emitting diode (LED) 37  
lithium battery 35  
hot-plug 60, 92  
indicators 76  
replacing 92  
standard 60  
power supply, redundant 60  
power-on indicator 68  
does not light 85  
PRIMECENTER Rack  
requirements 49  
PRIMECENTER rack  
installing server 52  
PRIMERGY Diagnostic  
LED 23  
Low Voltage Directive 26, 40  
M
MAC address 69  
Main memory 108  
mains voltage, connecting server 60  
management LAN connector 21, 59  
meaning of the symbols 25  
MegaRAID 17, 79  
memory module  
product name 46, 69  
property protection 83  
hot-spare memory 20  
inserting 108  
R
removing 108  
rack  
memory scrubbing 20  
monitor  
requirements 49  
RAID controller is not configured for  
display drifts 87  
this drive 89  
no display 87  
Mounting the anti-tilt bracket 48  
RAID level 20  
recycling devices 44  
regulations and standards 26  
Remote Storage 21  
removing, server 49  
Replacing the system fan 109  
replacing, power supply unit 92  
requirements  
N
NMI button 68, 69  
noise level 28  
notational conventions 25  
O
3rd party rack 50  
On/Off button 68, 69  
onboard SATA controller 17, 79  
configuring 81  
open, server 104  
operation 65  
DataCenter rack 49  
PRIMECENTER Rack 49  
reset button 68, 69  
return of devices 44  
routing  
overload 22  
cables 55  
P
S
packaging 43, 46  
PCI SAS controller, configuring 81  
PDA 20, 22  
Safety instructions 31  
safety standards 26  
SAS IME controller 17  
SAS MegaRAID controller 17  
power on indicator 70  
TX200 S6  
Operating Manual  
123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
SAS/SATA RAID controller 17  
configuring 79  
technical data 26  
transport 41  
saving energy 43  
screen  
troubleshooting 85  
unpacking 46  
ventilation clearance 27  
error message 89  
flickering 87  
weight 27  
remains blank 86  
shows flickering stripes 87  
SDDC, Single Device Data  
Correction 20  
security function 11  
serial number 46, 69  
server  
server management 22  
ServerView Installation Manager 23,  
ServerView Operations Manager 22  
supported functions 22  
ServerView Remote  
Management 24  
closing 114  
service  
configuration 23, 79  
connecting external devices 59  
connecting mains voltage 60  
connectors 59  
control panel 68  
correcting faults 85  
data protection 83  
dimensions 27  
electrical data 26  
fitting in rack 49  
hot-plug power supply unit 92  
indicators 68  
PRIMERGY Diagnostic LED 23  
server 23  
touch point 23  
service LAN connector 21  
setting up, server 47  
Single Device Data Correction  
(SDDC) 20  
Support bracket 53  
switch off time, defining 78  
switch on time, defining 78  
switching off, server 77  
switching on, server 77  
system board  
installing 49  
LAN connector 59  
NMI button 68  
noise level 28  
PRIMERGY Diagnostic LED 23  
system board, features 15  
system fan 1, 1&3  
open 104  
operation 65  
installing 112  
removing 106  
power on indicator 70  
product name 46  
property protection 83  
removing 49  
system fan 2, 2&4  
installing 113  
removing 105  
system information 69  
routing cables 55  
serial number 46  
service 23  
setting up 47  
starting up 65  
switches itself off (error) 86  
switching off 77  
switching on 77  
T
target group 12  
technical data 26  
ambient conditions 27  
time, incorrect 88  
tips 85  
touch point  
124  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaTdX.200 S6  
Index  
service 23  
TPM 15  
transport damage 29, 46  
transporting the server 41  
troubleshooting 85  
Trusted Platform Module 15  
U
unpacking, server 46  
USB connector 59, 68  
using the cable clamp 62  
V
ventilation clearance 27  
video connector 59  
W
weight 27  
TX200 S6  
Operating Manual  
125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Edimax Technology Network Router AC M1000 User Manual
Electro Voice Stereo Amplifier PSX 1650 User Manual
Fisher Price Games J2527 User Manual
Fluke Sewing Machine fluke123 User Manual
FoodSaver Food Saver Vac1050 User Manual
Frigidaire Freezer 297068500 User Manual
Fujitsu Laptop N6220 User Manual
Gemini Musical Instrument PMX 03 User Manual
Generac Portable Generator 005308 0 User Manual
Gigabyte Computer Hardware GA K8VT800 User Manual