Fluke Network Router 807 0115 User Manual

Visual UpTime Select  
ASE model 807-0115  
4xT1/E1 inline probe ASE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® Select™ 4xT1/E1 inline probe  
ASE enhances the data analysis functionality of the  
Visual UpTime Select system for enterprises with  
two-to-four T1 or E1 circuits terminating at a single  
location. The ASE provides up to 6.176 Mbps  
(T-standard) or 8.192 Mbps (E-standard) of detailed  
network traffic analysis and management, while  
maintaining full wire speed pass-through of all  
traffic. In its initial release, the ASE supports IP  
Transport software over MultiLink Point-to-Point  
Protocol (MLPPP) T1 links.  
The 4xT1/E1 ASE includes LinkSafe™ technology  
to protect circuit integrity in case of a power outage  
and it also delivers a notification alarm if there is a  
power failure.  
Key features  
• Four management ports  
• MLPPP support on IP Transport software  
• Inband management capability  
• LinkSafe technology  
Designed for locations with multiple circuits  
terminating at a single device, the 4xT1/E1 is typi-  
cally deployed as an inline probe between the service  
provider’s edge device and the customer’s termination  
equipment. The figure below highlights the multilink  
deployment for the 4xT1/E1 ASE.  
• Power loss detection  
• Service Level Agreement (SLA) metrics  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Realtime events  
4xT1/E1 inline probe model 807-0115 front  
4xT1/E1 inline probe model model 807-0115 rear  
Optional LAN Connection  
Bundled  
T1 Line  
WAN  
CPE Router  
4xT1/E1 inline ASE  
LAN  
4xT1/E1 inline probe model 807-0115 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
Visual UpTime Select  
ASE model 807-0113  
T1/E1 inline probe ASE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® SelectT1/E1 LinkSafe™ inline  
When configured for use on an E1 network, the ASE  
complies with the physical/electrical characteristics  
defined by ITU-T G.703 at 2.048 Megabits per second  
(Mbps). The ASE also complies with the synchronous  
frame structure specifications defined by ITU-T G.704,  
including the option to use channel 16 for data or  
signalling. You can either connect to the E1 network  
using a 120 ohm balanced cable or BNC coax 75 ohm  
unbalanced cables.  
Key features  
probe ASE is deployed inline on a T1 or E1 access line,  
• Inband management capabilities  
typically between a service provider’s edge device and  
CSU/DSU. This ASE supports Multi-Protocol software  
for deployment in standard frame relay or HDLC  
networks and IP Transport software for deployment  
in frame relay or HDLC-based networks that use IP  
switching. The ASE also includes LinkSafe technology  
to protect circuit integrity in case of an ASE outage,  
as well as power failure notification.  
• LinkSafe technology  
• Power loss detection  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Realtime events  
T1/E1 inline probe model 807-0113 front view  
T1/E1 inline probe model model 807-0113 rear view  
Optional LAN Connection  
T1/E1 Access Line  
LAN  
WAN  
T1/E1 inline ASE  
CSU/DSU  
CPE Router  
Visual UpTime  
Select Server  
T1/E1 inline probe model 807-0113 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
T1/E1 inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
General  
Dimensions  
8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)  
2.10 lbs.  
Weight  
Data Rate  
Timing Mode  
1.544 Mbps synchronous  
Derived externally from the T1 or E1 network,  
user interface, or internally from the ASE.  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 80%, noncondensing  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Operating and Storage  
Humidity  
Input  
100 to 240 VAC  
Power Requirements  
T1 Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Line Rate  
0.5 amps  
1.544 Mbps 50 bps synchronous  
AMI or B9ZS line coding  
ESF or D4 framing formats  
0dB to -36dB  
Line Format  
Framing  
Input Signal  
Output Signal  
Pulse Density  
Connector  
Hardware Warranties  
0, -7.5dB, -15dB, -22.5dB LBO  
AT&T 62411  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
8-pin modular jack—USOC: RJ48C  
Network, User, or Internal  
1 to 24 channels in any combination  
2.048 Mbps 102.4 bps synchronous  
HDB3 or AMI line coding  
CRC4 or FAS framing formats  
CAS, CCS, or Data  
Timing  
Channel Selection  
Line Rate  
E1 Network Interface  
Line Format  
Framing  
Time Slot 16  
Input Signal  
Output Signal  
Connector  
Ordering Information  
0dB to -43dB  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
0dB to LBO  
RJ-45 (100 ohm balanced)  
or BNC (75 ohm unbalanced)  
Channel Selection  
1-31 (includes channel 16  
or 1-15, 17-31 (does not include channel 16)  
Baud Rate  
Parity  
19200 or 9600 bps  
8 data bits, no parity  
1 stop bit  
Serial Port Interface  
Stop Bit  
Electrical Format  
Connector  
Bite Rate  
EIA RS-232, DTE  
RJ-45  
10 or 100 Mbps  
Ethernet 10/100BaseT  
Interface  
Connector  
8-pin modular jack: RJ-48  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643532 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0120  
10/100 Ethernet inline ASE LE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® Select™ 10/100 Ethernet  
line between LAN devices, such as the LAN switch  
and router (see figure). Other options include posi-  
tioning the ASE on the Ethernet segment between a  
subscriber’s router and a Network Terminating Unit  
(NTU) such as a DSL modem or a Service Provider  
switch (Ethernet as WAN access), or connecting the  
ASE to a router or switch SPAN port.  
Key features  
inline ASE LE enhances the analysis functionality  
of the Visual UpTime Select system for Ethernet  
networks. The ASE provides up to 6 Mbps of detailed  
network traffic analysis and management, while  
maintaining full wire speed pass-through of all traf-  
fic. It supports both IP Transport and LAN Visibility  
software When deployed inline, the ASE includes  
LinkSafe™ technology to protect circuit integrity if  
in case of an ASE outage, as well as power failure  
notification.  
• Inline or SPAN mode deployment  
• LinkSafe technology  
• IP Transport or LAN Visibility software  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LAN management port  
The LAN Visibility Ethernet ASE is deployed on  
the LAN. The inline LAN Visibility ASE collects and  
displays application flow traffic on the LAN between  
clients and application server. In contrast, the IP  
Transport ASE is designed to display only traffic to or  
from the WAN, and ignore local traffic (such as be-  
tween a client and an Internet or application server).  
• Power loss detection  
• Realtime events  
Designed for business class DSL and cable, the  
10/100 Ethernet inline ASE LE has a wide variety of  
deployment options. The IP Transport Ethernet ASE is  
typically deployed as an inline probe on the access  
Ethernet inline probe model 807-0120 front view  
Client  
Access  
Line(s)  
Wide Area  
Network  
NTU  
Customer IP Transport LAN Switch  
Server  
Ethernet ASE  
device Edge Router  
LAN  
LAN Visibility  
Ethernet ASE  
Ethernet inline probe model 807-0120 deployed inline IP Transport and on LAN in LAN Visibility mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
Ethernt inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
7.5” (19.1 cm) x 6” (15.2 cm) x 1.5” (3.8 cm)  
2.10 lbs.  
General  
Weight  
Maximum Data Rate  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Input  
6 Mbps  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
100 to 240 VAC  
Environment  
Power Requirements  
Frequency  
50/60 Hz  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Input Current Rating  
Bit Rate  
0.5 amps  
10/100 Mbps  
LAN and WAN  
Ethernet Interface  
Connector  
8-pin modular jack: RJ-45  
19200 or 9600 bps  
8 data bits, no parity  
1 stop bit  
Baud Rate  
Serial Port Interface  
Parity  
Stop Bit  
Electrical Format  
Connector  
EIA RS-232, DTE  
RJ-45  
Hardware Warranties  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Ethernet inline probe model model 807-0120 rear view  
Ordering Information  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643441 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0122  
10/100 Ethernet inline ASE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® Select™ 10/100 Ethernet  
line between LAN devices, such as the LAN switch  
and router (see figure). Other options include posi-  
tioning the ASE on the Ethernet segment between a  
subscriber’s router and a Network Terminating Unit  
(NTU) such as a DSL modem or a Service Provider  
switch (Ethernet as WAN access), or connecting the  
ASE to a router or switch SPAN port.  
Key features  
inline ASE enhances the analysis functionality of the  
Visual UpTime Select system for Ethernet networks.  
The ASE provides up to 100 Mbps of detailed network  
traffic analysis and management, while maintaining  
full wire speed pass-through of all traffic. It supports  
both IP Transport and LAN Visibility software When  
deployed inline, the ASE includes LinkSafe™ technol-  
ogy to protect circuit integrity if in case of an ASE  
outage, as well as power failure notification.  
• Inline or SPAN mode deployment  
• LinkSafe technology  
• IP Transport or LAN Visibility software  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• Power loss detection  
The LAN Visibility Ethernet ASE is deployed on  
the LAN. The inline LAN Visibility ASE collects and  
displays application flow traffic on the LAN between  
clients and application server. In contrast, the IP  
Transport ASE is designed to display only traffic to or  
from the WAN, and ignore local traffic (such as be-  
tween a client and an Internet or application server).  
• LAN management port  
• Realtime events  
Designed for business class DSL and cable, the  
10/100 Ethernet inline ASE has a wide variety of  
deployment options. The IP Transport Ethernet ASE is  
typically deployed as an inline probe on the access  
Ethernet inline probe model 807-0122 front view  
Client  
Access  
Line(s)  
Wide Area  
Network  
NTU  
Customer IP Transport LAN Switch  
Server  
Ethernet ASE  
device Edge Router  
LAN  
LAN Visibility  
Ethernet ASE  
Ethernet inline probe model 807-0122 deployed inline IP Transport and on LAN in LAN Visibility mode  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
Ethernt inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
7.5” (19.1 cm) x 6” (15.2 cm) x 1.5” (3.8 cm)  
2.10 lbs.  
General  
Weight  
Maximum Data Rate  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Input  
100 Mbps  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
100 to 240 VAC  
Environment  
Power Requirements  
Frequency  
50/60 Hz  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Input Current Rating  
Bit Rate  
0.5 amps  
10/100 Mbps  
LAN and WAN  
Ethernet Interface  
Connector  
8-pin modular jack: RJ-45  
19200 or 9600 bps  
8 data bits, no parity  
1 stop bit  
Baud Rate  
Serial Port Interface  
Parity  
Stop Bit  
Electrical Format  
Connector  
EIA RS-232, DTE  
RJ-45  
Hardware Warranties  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Ordering Information  
Ethernet inline probe model model 807-0122 rear view  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643434 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0220  
10/100/1000 Ethernet ASE  
With SPAN mode capabilities  
The Visual UpTime® Select™ 10/100/1000 Ethernet  
ASE enhances the analysis functionality of Visual  
UpTime Select for Ethernet networks. The ASE  
provides up to 500 Mbps of detailed network traffic  
analysis and management, while maintaining full wire  
speed pass-through of all traffic. It supports both IP  
Transport and LAN Visibility software  
The LAN Visibility Ethernet ASE is deployed on the  
LAN. The ASE collects and displays application flow  
traffic on the LAN between clients and application  
server. In contrast, the IP Transport ASE is designed  
to display only traffic to or from the WAN, and ignore  
local traffic (such as between a client and an Inter-  
net or application server).  
Key features  
• 500 MB of total analysis  
• SPAN mode deployment  
• Deployable in DS3, NxDS3, Fractional  
OC3, and Ethernet to Premises topologies  
• IP Transport or LAN Visibility software  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LAN management port  
Designed for business class DSL and cable, the  
10/100/1000 Ethernet ASE has a wide variety of  
deployment options. The IP Transport Ethernet ASE is  
deployed off a LAN switch SPAN port (see figure).  
• Realtime events  
Ethernet inline probe model 807-0220 front view  
Ethernet inline probe model model 807-0220 rear view  
Customer  
Edge Router  
LAN Switch  
Wide Area  
Network  
SPAN port  
Ethernet ASE  
LAN  
Ethernet probe model 807-0220 deployed on a LAN switch SPAN port  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
Ethernt inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
17.3” (43.9 cm) x 12” (30.5 cm) x 3.5” (8.9 cm)  
10.45 lbs.  
General  
Weight  
Maximum Data Rate  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Input  
500 Mbps  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
100 to 240 VAC  
Environment  
Power Requirements  
Frequency  
50/60 Hz  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Input Current Rating  
Bit Rate  
0.5 amps  
10/100/1000 Mbps  
LAN and WAN  
Ethernet Interface  
Connector  
8-pin modular jack: RJ-45  
19200 or 9600 bps  
Baud Rate  
Serial Port Interface  
Parity  
8 data bits, no parity  
1 stop bit  
Stop Bit  
Electrical Format  
Connector  
EIA RS-232, DTE  
9-pin D, male per EIA-574  
Hardware Warranties  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Ordering Information  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643429 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0106  
HSSI inline probe ASE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® SelectHSSI LinkSafe™ inline  
The ASE also includes LinkSafe technology to protect  
circuit integrity in case of an ASE outage, as well as  
power failure notification.  
Key features  
probe ASE is deployed inline on a High Speed Serial  
• Inband management capabilities  
Interface (HSSI) access line, typically between a  
CSU/DSU and customer edge router. It is capable of  
monitoring traffic flowing through a bi-directional  
HSSI connection at data rates up to 44.7 Mbps.  
The HSSI ASE supports Multi-Protocol software for  
deployment in standard frame relay or HDLC networks  
and IP Transport software for deployment in frame  
relay or HDLC-based networks that use IP switching.  
The HSSI ASE has two HSSI interfaces, Data Ter-  
minal Equipment (DTE) for monitoring traffic to the  
network and Data Communication Equipment (DCE)  
for monitoring traffic from the network. Because of  
its high speed capabilities, a HSSI ASE can support  
data passed through the CSU/DSU from NxT1  
and DS3 lines.  
• LinkSafe technology  
• Power loss detection  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Realtime events  
HSSI inline probe model 807-0106 front view  
HSSI inline probe model model 807-0106 rear view  
Optional LAN  
Connection  
Access Line  
LAN  
WAN  
CSU/DSU  
Inline ASE  
CPE Router  
Visual UpTime  
Select Server  
HSSI inline probe model 807-0106 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
HSSI inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
17.3” (43.9 cm) x 12” (30.5 cm) x 3.5” (8.9 cm)  
10.45 lbs.  
General  
Weight  
Data Rate  
Timing Mode  
0 to 44.736 Mbps synchronous  
RD: Always synchronous with SCR  
SD: Synchronous with SCT or SCTE  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 80%, noncondensing  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Environment  
Power Requirements  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Operating and Storage  
Humidity  
Input  
100 to 240 VAC  
50/60 Hz  
Frequency  
Input Current Rating  
Configuration  
1 amp  
Two HSSI interfaces: one DTE and one DCE for  
monitoring to-network and from-network traffic.  
HSSI Interface  
Baud Rate  
Parity  
19200 or 9600 bps  
8 data bits, no parity  
1 stop bit  
Serial Port Interface  
Stop Bit  
Hardware Warranties  
Electrical Format  
Connector  
Bite Rate  
EIA RS-232, DTE  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
9-pin D, male per EIA-574  
10 or 100 Mbps  
Ethernet 10/100BaseT  
Interface  
Connector  
8-pin modular jack: RJ-48  
Ordering Information  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643476 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0104  
V.35 inline probe ASE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® SelectV.35 LinkSafe™ inline  
The V.35 inline probe ASE supports V.35 connectiv-  
ity through a V.35 Data Terminal Equipment (DTE)  
interface on the network side and Data Communica-  
tions Equipment (DCE) interface on the user side.  
The ASE operates at data rates up to 2.048 Mbps,  
deriving timing from the network-side and sourcing  
timing on the user side. It also includes LinkSafe  
technology to protect circuit integrity in case of an  
ASE outage, as well as power failure notification.  
Key features  
probe ASE is deployed inline on a T1 access line,  
• Inband management capabilities  
typically between a CSU/DSU and customer premises  
equipment. This ASE supports Multi-Protocol software  
for deployment in standard frame relay or HDLC  
networks and IP Transport software for deployment  
in frame relay or HDLC-based networks that use IP  
switching.  
• LinkSafe technology  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Power loss detection  
• Realtime events  
V.35 inline probe model 807-0104 front view  
V.35 inline probe model model 807-0104 rear view  
Optional LAN  
Connection  
Access Line  
LAN  
WAN  
CSU/DSU  
Inline ASE  
CPE Router  
Visual UpTime  
Select Server  
V.35 inline probe model 807-0104 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
V.35 inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)  
Plastic case with internal power supply  
General  
Weight  
2.10 lbs.  
Data Rate  
Timing Mode  
0 to 2.048 Mbps synchronous  
RD: Always synchronous with SCR  
SD: Synchronous with SCT or SCTE  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 80%, noncondensing  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Operating and Storage  
Humidity  
Input  
100 to 240 VAC  
Power Requirements  
Frequency  
50/60 Hz  
Input Current Rating  
Configuration  
Data and Clock Leads  
Signaling Leads  
Connector  
0.5 amps  
DCE for interfacing with DTE  
ITU-T V.35  
V.35 User Interface  
(DCE)  
EIA RS-232 (ITU-T V.28)  
Female 34-pin V.35 connector  
RTS, DTR  
Hardware Warranties  
Signaling  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Configuration  
Data and Clock Leads  
Signaling Leads  
Connector  
DTE for interfacing with DCE  
ITU-T V.35  
V.35 Network  
Interface  
(DTE)  
EIA RS-232 (ITU-T V.28)  
Female 34-pin V.35 connector  
CTS, RLSD, DSR  
Signaling  
Baud Rate  
19200 or 9600 bps  
8 data bits, no parity  
1 stop bit  
Serial Port Interface  
Parity  
Ordering Information  
Stop Bit  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
Electrical Format  
Connector  
EIA RS-232, DTE  
RJ-45  
Bite Rate  
10 or 100 Mbps  
Ethernet 10/100BaseT  
Interface  
Connector  
8-pin modular jack: RJ-48  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643465 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0105  
X.21 inline probe ASE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® SelectX.21 LinkSafe™ inline  
The ASE supports X.21 connectivity through a X.21  
Data Terminal Equipment (DTE) interface on the  
network side and Data Communications Equipment  
(DCE) interface on the user side.  
Key features  
probe ASE is deployed inline on an access line, typical-  
• Inband management capabilities  
ly between a CSU/DSU and customer premises equip-  
ment (CPE). It supports Multi-Protocol software for  
deployment in standard frame relay or HDLC networks  
and IP Transport software for deployment in frame  
relay or HDLC-based networks that use IP switching.  
• LinkSafe technology  
The ASE operates at data rates up to 2.048 Mbps,  
deriving timing from the network-side and sourcing  
timing on the user side. It also includes LinkSafe  
technology to protect circuit integrity in case of an  
ASE outage, as well as power failure notification.  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Power loss detection  
• Realtime events  
X.21 inline probe model 807-0105 front view  
X.21 inline probe model model 807-0105 rear view  
Optional LAN  
Connection  
Access Line  
LAN  
WAN  
CSU/DSU  
Inline ASE  
CPE Router  
Visual UpTime  
Select Server  
X.21 inline probe model 807-0105 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
X.21 inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)  
Plastic case with internal power supply  
General  
Weight  
2.10 lbs.  
Data Rate  
Timing Mode  
0 to 2.048 Mbps synchronous  
RD: Always synchronous with SCR  
SD: Synchronous with SCT or SCTE  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 80%, noncondensing  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Operating and Storage  
Humidity  
Input  
100 to 240 VAC  
Power Requirements  
Frequency  
50/60 Hz  
Input Current Rating  
Configuration  
Data and Clock Leads  
Signaling Leads  
Connector  
0.5 amps  
DCE for interfacing with DTE  
ITU-CCITT X.21  
X.21 User Interface  
(DCE)  
ITU-CCITT X.21  
Female 15-pin X.21 connector  
Hardware Warranties  
Signaling  
Indicate: Clear to Send control signal to the user  
interface. Received and terminated by the ASE.  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Configuration  
Data and Clock Leads  
Signaling Leads  
Connector  
DTE for interfacing with DCE  
ITU-CCITT X.21  
X.21 Network  
Interface (DTE)  
ITU-CCITT X.21  
Female 15-pin X.21 connector  
Signaling  
Control: Request to Send control signal from the  
user interface. On while power is applied by the  
ASE.  
Ordering Information  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
Baud Rate  
Parity  
19200 or 9600 bps  
8 data bits, no parity  
1 stop bit  
Serial Port Interface  
Stop Bit  
Electrical Format  
Connector  
Bite Rate  
EIA RS-232, DTE  
RJ-45  
10 or 100 Mbps  
Ethernet 10/100BaseT  
Interface  
Connector  
8-pin modular jack: RJ-48  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643152 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0200  
DS3 inline probe ASE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® SelectDS3 LinkSafe™ inline  
The DS3 inline probe ASE is designed for deploy-  
ment at the network demarcation point between a  
subscriber’s CPE and the WAN. It can be deployed in  
ATM and mixed frame relay-ATM environments. The  
figure below shows the ASE positioned at the edge of  
an inter-worked frame relay-to-ATM network, allowing  
for SLA messaging between a frame relay DLCI and an  
ATM VPI/VCI.  
Key features  
probe ASE complies with Class A standards for  
• Inband management capabilities  
countries using DS3 ATM lines (U.S. and Canada) and  
supports digital transmission at the DS3 rate of 44  
Mbps. This ASE supports Multi-Protocol software for  
deployment in standard ATM networks and IP Trans-  
port software for deployment in ATM-based networks  
that use IP switching. The ASE also includes LinkSafe  
technology to protect circuit integrity in case of an  
ASE outage, as well as power failure notification.  
• LinkSafe technology  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Application analysis capability  
• LAN management port  
• Realtime events  
DS3 inline probe model 200 front view  
DS3 inline probe model 200 rear view  
LAN  
Branch ASEs  
Visual  
UpTime  
Select  
server  
Frame to ATM  
Interworking  
T1  
CPE  
Router  
ATM ASE  
Frame  
Network  
ATM  
Network  
DS3 inline probe model 200 on ATM/Frame network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
DS3 inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
1 EIA unit (1.75”) high x 19” wide rack-mountable  
chassis  
General  
Weight  
10 lbs.  
Data Rate  
to 45 Mbps synchronous  
Derived externally from the network.  
0o to +40oC (+32o to +104oF)  
-20o to +55oC (-4o to +131oF)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90% non-condensing  
100 to 240 VAC  
Timing Mode  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Operating/Storage Humidity  
Input  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Power Requirements  
Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Line Rate  
0.5 amps  
44.736 Mbps  
Cell Delineation  
Cell Scrambler  
Line Build Out  
Connector  
HEC or PLCP  
Enable or Disable  
Long = more than 225 feet. Short = 225 feet or less.  
4 BNC (75 ohm), Network Tx and Rx, CPE Tx and Rx  
57600, 19200, or 9600 bps  
8 data bits, no parity  
1 stop bit  
Hardware Warranties  
Baud Rate  
Serial Port Interface  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Parity  
Stop Bit  
Electrical Format  
Connector  
EIA RS-232, DTE  
9-pin D, male per EIA-574  
10 or 100 Mbps  
Bite Rate  
Ethernet 10/100BaseT  
Interface  
Connector  
8-pin modular jack: RJ-48  
Ordering Information  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643490 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0201  
E3 inline probe ASE  
W i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® Select™ E3 LinkSafe™ inline  
The E3 inline probe ASE is designed for deploy-  
ment at the network demarcation point between a  
subscriber’s CPE and the WAN. It can be deployed in  
ATM and mixed frame relay-ATM environments. The  
figure below shows the ASE positioned at the edge of  
an inter-worked frame relay-to-ATM network, allowing  
for SLA messaging between a frame relay DLCI and an  
ATM VPI/VCI.  
Key features  
probe ASE complies with Class A standards for  
countries using E3 ATM lines and supports digital  
transmission at the E3 rate of 34 Mbps. This ASE  
supports Multi-Protocol software for deployment in  
standard ATM networks and IP Transport software  
for deployment in ATM-based networks that use IP  
switching. The ASE also includes LinkSafe technology  
to protect circuit integrity in case of an ASE outage,  
as well as power failure notification.  
• Inband management capabilities  
• LinkSafe technology  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Application analysis capability  
• LAN management port  
• Realtime events  
E3 inline probe model 201 front view  
E3 inline probe model 201 rear view  
LAN  
Branch ASEs  
Visual  
UpTime  
Select  
server  
Frame to ATM  
Interworking  
T1  
CPE  
Router  
ATM ASE  
Frame  
Network  
ATM  
Network  
E3 inline probe model 201 on ATM/Frame network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
E3 inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
1 EIA unit (1.75”) high x 19” wide rack-mountable  
chassis  
General  
Weight  
10 lbs.  
Data Rate  
to 34 Mbps synchronous  
Derived externally from the network.  
0o to +40oC (+32o to +104oF)  
-20o to +55oC (-4o to +131oF)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90% non-condensing  
100 to 240 VAC  
Timing Mode  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Operating/Storage Humidity  
Input  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Power Requirements  
Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Line Rate  
0.5 amps  
34.368 Mbps  
Cell Delineation  
Cell Scrambler  
Connector  
HEC or PLCP  
Enable or Disable  
4 BNC (75 ohm), Network Tx and Rx, CPE Tx and Rx  
57600, 19200, or 9600 bps  
8 data bits, no parity  
1 stop bit  
Baud Rate  
Serial Port Interface  
Hardware Warranties  
Parity  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Stop Bit  
Electrical Format  
Connector  
EIA RS-232, DTE  
9-pin D, male per EIA-574  
10 or 100 Mbps  
Bite Rate  
Ethernet 10/100BaseT  
Interface  
Connector  
8-pin modular jack: RJ-48  
Ordering Information  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643483 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0202  
OC-3c/STM-1 inline probe ASE  
S i n g l e m o d e w i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® SelectOC-3c/STM-1 LinkSafe™  
inline probe ASE supports single mode ATM OC-3c  
physical lines, with SONET and SDH standards, at  
speeds up to 155 Mbps. This ASE supports Multi-Proto-  
col software for deployment in standard ATM networks  
and IP Transport software for deployment in ATM-based  
networks that use IP switching. The ASE also includes  
LinkSafe technology to protect circuit integrity in case  
of an ASE outage, as well as power failure notification.  
The OC-3c/STM-1 inline probe ASE is designed  
Key features  
for deployment at the network demarcation point  
between a subscriber’s CPE and the WAN. It can be  
deployed in ATM and mixed frame relay-ATM environ-  
ments. The figure below shows the ASE positioned  
at the edge of an inter-worked frame relay-to-ATM  
network, allowing for SLA messaging between a frame  
relay DLCI and an ATM VPI/VCI.  
• Inband management capabilities  
• LinkSafe technology  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Application analysis capability  
• LAN management port  
• Realtime events  
OC-3c inline probe model 202 front view  
OC-3c inline probe model 202 rear view  
LAN  
Branch ASEs  
Visual  
UpTime  
Select  
server  
Frame to ATM  
Interworking  
T1  
CPE  
Router  
OC-3c  
ATM ASE  
Frame  
Network  
ATM  
Network  
OC-3c inline probe model 202 on ATM/Frame network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
OC-3c inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
1 EIA unit (1.75”) high x 19” wide rack-mountable  
chassis  
General  
Weight  
10 lbs.  
Data Rate  
to 155 Mbps synchronous  
Derived externally from the network.  
0o to +40oC (+32o to +104oF)  
-20o to +55oC (-4o to +131oF)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90% non-condensing  
100 to 240 VAC  
Timing Mode  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Operating/Storage Humidity  
Input  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Power Requirements  
Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Bypass  
0.5 amps  
5 volt 1 amp DC  
Line Rate  
155.52 Mbps  
Line Mode  
SONET or SDH  
Cell Delineation  
Cell Scrambler  
Connectors  
HEC  
Enable or Disable  
Hardware Warranties  
2 Sff Duplex-LC, Network Tx and Rx, CPE Tx and Rx  
1274 nm/1356 nm  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Wavelength  
Tx Average Output Power  
Rx Sensitivity  
Baud Rate  
-11dBm (typical) Measured with single mode cable  
-33dBm (typical)  
57600, 19200, or 9600 bps  
8 data bits, no parity  
1 stop bit  
Serial Port Interface  
Parity  
Stop Bit  
Electrical Format  
Connector  
EIA RS-232, DTE  
Ordering Information  
9-pin D, male per EIA-574  
10 or 100 Mbps  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
Bite Rate  
Ethernet 10/100BaseT  
Interface  
Connector  
8-pin modular jack: RJ-48  
Compliant with Bellcore GR-253 CORE and ITE G.957 standards  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643526 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0203  
OC-3c/STM-1 inline probe ASE  
M u l t i m o d e w i t h L i n k S a f e c a p a b i l i t i e s  
The Visual UpTime® SelectOC-3c/STM-1 LinkSafe™  
The OC-3c/STM-1 inline probe ASE is designed  
for deployment at the network demarcation point  
between a subscriber’s CPE and the WAN. It can be  
deployed in ATM and mixed frame relay-ATM environ-  
ments. The figure below shows the ASE positioned  
at the edge of an inter-worked frame relay-to-ATM  
network, allowing for SLA messaging between a frame  
relay DLCI and an ATM VPI/VCI.  
Key features  
inline probe ASE supports multimode ATM OC-3c  
• Inband management capabilities  
physical lines, with SONET and SDH standards, at  
speeds up to 155 Mbps. This ASE supports Multi-  
Protocol software for deployment in standard ATM  
networks and IP Transport software for deployment in  
ATM-based networks that use IP switching. The ASE  
also includes LinkSafe technology to protect circuit  
integrity in case of an ASE outage, as well as power  
failure notification.  
• LinkSafe technology  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Application analysis capability  
• LAN management port  
• Realtime events  
OC-3c inline probe model 203 front view  
OC-3c inline probe model 203 rear view  
LAN  
Branch ASEs  
Visual  
UpTime  
Select  
server  
Frame to ATM  
Interworking  
T1  
CPE  
Router  
OC-3c  
ATM ASE  
Frame  
Network  
ATM  
Network  
OC-3c inline probe model 203 on ATM/Frame network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
OC-3c inline probe ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
1 EIA unit (1.75”) high x 19” wide rack-mountable  
chassis  
General  
Weight  
10 lbs.  
Data Rate  
to 155 Mbps synchronous  
Derived externally from the network.  
0o to +40oC (+32o to +104oF)  
-20o to +55oC (-4o to +131oF)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90% non-condensing  
100 to 240 VAC  
Timing Mode  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Operating/Storage Humidity  
Input  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Power Requirements  
Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Bypass  
0.5 amps  
5 volt 1 amp DC  
Line Rate  
155.52 Mbps  
Line Mode  
SONET or SDH  
Cell Delineation  
Cell Scrambler  
Connectors  
HEC  
Enable or Disable  
Hardware Warranties  
2 Sff Duplex-LC, Network Tx and Rx, CPE Tx and Rx  
1270 nm/1380 nm  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Wavelength  
Tx Average Output Power  
-16dBm (typical) Measured with 62.5µ/120  
Multimedia cable  
Rx Sensitivity  
Baud Rate  
Parity  
-33dBm (typical)  
57600, 19200, or 9600 bps  
8 data bits, no parity  
1 stop bit  
Serial Port Interface  
Stop Bit  
Electrical Format  
Connector  
Bite Rate  
EIA RS-232, DTE  
Ordering Information  
9-pin D, male per EIA-574  
10 or 100 Mbps  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
Ethernet 10/100BaseT  
Interface  
Connector  
8-pin modular jack: RJ-48  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643515 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0109  
T1 CSU/DSU ASE  
W i t h D S X - 1 , D r o p - a n d - I n s e r t c a p a b i l i t i e s  
The Visual UpTime® SelectT1 CSU/DSU ASE is  
deployed on a T1 access line at the demarcation point  
between the provider network and customer premises.  
It supports full and fractional (FT1) T1 networks and  
provides connectivity through V.35 and additional  
digital cross connect signal (DSX-1) interfaces.  
The ASE supports Multi-Protocol software for deploy-  
ment in standard frame relay or HDLC networks and  
IP Transport software for deployment in frame relay or  
HDLC-based networks that use IP switching.  
In addition to performing standard CSU/DSU  
Key features  
functions—such as BER tests, loopbacks, and power  
failure detection—the ASE is capable of inserting  
management traffic.  
• Inband management capabilities  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Drop-and-Insert capabilities through  
DSX port  
The ASE’s “drop-and-insert” feature provides a  
secondary DSX-1 port that can connect to a Private  
Branch Exchange at a customer’s site. T1 Timeslots  
can be segmented for a PBX on the same circuit car-  
rying data traffic (see figure).  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Power loss detection  
• Realtime events  
T1 CSU/DSU model 807-0109 front view  
T1 CSU/DSU model 807-0109 rear view  
CSU/DSU  
ASE  
T1 Access  
V.35  
Line  
Line  
Wide Area  
Network  
Visual  
UpTime  
Select  
Optional LAN  
Connection  
PBX  
PBX  
Server  
TelephoTneelephone  
T1 CSU/DSU model 807-0109 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
T1 CSU/DSU ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)  
Plastic case with internal power supply.  
General  
Weight  
2.10 lbs.  
Data Rate  
Timing Mode  
1.544 Mbps synchronous  
Derived externally from the T1 network or DSX-1  
interface, or internally from the ASE.  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90%, noncondensing  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Operating and Storage  
Humidity  
Input  
100 to 120 VAC  
Power Requirements  
T1 Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Line Rate  
0.5 amps  
1.544 Mbps 50 bps synchronous  
AMI or B9ZS line coding  
ESF or D4 framing formats  
ANSI T1.403, AT&T TR54016, Both, or None  
0dB to -36dB  
Line Format  
Framing  
ESF FDL  
Hardware Warranties  
Input Signal  
Output Signal  
Pulse Density  
Connector  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
0, -7.5dB, -15dB, -22.5dB LBO  
AT&T 62411  
8-pin modular jack—USOC: RJ48C  
Loop, DSX-1, or Internal  
1 to 24 channels in any combination  
DCE for interfacing with DTE  
ITU-T V.35  
Timing  
Channel Selection  
Configuration  
Data and Clock Leads  
Signaling Leads  
Data Rates  
Network DTE Interface  
(Data Port)  
Ordering Information  
EIA RS-232 (ITU-T V.28)  
56 kbps x N or 64 kbps x N (N = 1 through 24)  
Selectable V.35 data inversion  
Network selected-source timing  
SCT, inverted SCT, SCTE  
RLSD, CTS  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
HDLC Inversion  
Transmit Timing Basis  
Receive Timing Basis  
Receive Line Data Not Valid  
Connector  
Female 34-pin V.35 connector  
1.544 Mbps 50 bps  
Line Rate  
DSX-1 Interface  
Line Format  
AMI or B8ZS  
Framing  
ESF or D4 (SF)  
Input Signal  
Line Equalization  
Connector  
-1dB to -11dB  
0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft  
RJ-45  
Channel Selection  
Specifications  
1 to 24 channels in any combination  
N E T W O R K S U P E R V I S I O N  
19200 or 9600 bps baud rate, 8 data bits no parity,  
1 stop bit, EIA RS-232 DTE electrical format, RJ-45  
connector  
Serial Port Interface  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
Bite Rate  
Connector  
10 or 100 Mbps  
Ethernet 10/100BaseT  
Interface  
8-pin modular jack: RJ-48  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643395 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0110  
T1 CSU/DSU ASE  
The Visual UpTime® SelectT1 CSU/DSU ASE is  
IP Transport software for deployment in frame relay or  
HDLC-based networks that use IP switching.  
In addition to performing standard CSU/DSU  
functions—such as BER tests, loopbacks, and power  
failure detection—the ASE is capable of inserting  
management traffic.  
Key features  
deployed on a T1 access line at the demarcation point  
between the provider network and customer premises.  
It supports full and fractional (FT1) T1 networks and  
provides connectivity through V.35 interface.  
• Inband management capabilities  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LMI spoofing  
The ASE supports Multi-Protocol software for deploy-  
ment in standard frame relay or HDLC networks and  
• LAN management port  
• Power loss detection  
• Realtime events  
T1 CSU/DSU model 807-0110 front view  
T1 CSU/DSU model 807-0110 rear view  
Demarcation Point  
T1 Access  
Line  
V.35  
Line  
Wide Area  
Network  
CSU/DSU  
ASE  
Visual  
UpTime  
Select  
Server  
Optional LAN  
Connection  
T1 CSU/DSU model 807-0110 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
T1 CSU/DSU ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)  
Plastic case with internal power supply.  
General  
Weight  
2.10 lbs.  
Data Rate  
Timing Mode  
1.544 Mbps synchronous  
Derived externally from the T1 network or DSX-1  
interface, or internally from the ASE.  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90%, noncondensing  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Operating and Storage  
Humidity  
Input  
100 to 120 VAC  
Power Requirements  
T1 Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Line Rate  
0.5 amps  
1.544 Mbps 50 bps synchronous  
AMI or B9ZS line coding  
ESF or D4 framing formats  
ANSI T1.403, AT&T TR54016, Both, or None  
0dB to -36dB  
Line Format  
Framing  
ESF FDL  
Hardware Warranties  
Input Signal  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Output Signal  
Pulse Density  
Connector  
0, -7.5dB, -15dB, -22.5dB LBO  
AT&T 62411  
8-pin modular jack—USOC: RJ48C  
Loop, DSX-1, or Internal  
1 to 24 channels in any combination  
DCE for interfacing with DTE  
ITU-T V.35  
Timing  
Channel Selection  
Configuration  
Data and Clock Leads  
Signaling Leads  
Data Rates  
Network DTE Interface  
(Data Port)  
Ordering Information  
EIA RS-232 (ITU-T V.28)  
56 kbps x N or 64 kbps x N (N = 1 through 24)  
Selectable V.35 data inversion  
Network selected-source timing  
SCT, inverted SCT, SCTE  
RLSD, CTS  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
HDLC Inversion  
Transmit Timing Basis  
Receive Timing Basis  
Receive Line Data Not Valid  
Connector  
Female 34-pin V.35 connector  
Specifications  
19200 or 9600 bps baud rate, 8 data bits no parity,  
1 stop bit, EIA RS-232 DTE electrical format, RJ-45  
connector  
Serial Port Interface  
Bite Rate  
Connector  
10 or 100 Mbps  
Ethernet 10/100BaseT  
Interface  
8-pin modular jack: RJ-48  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643388 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0111  
T1 CSU/DSU ASE  
W i t h M o d e m  
The Visual UpTime® SelectT1 CSU/DSU ASE is  
This ASE features an internal modem that allows  
users to establish a telephone connection to either  
the ASE’s administrative interface or a pass-through  
connection through the serial port.  
Key features  
deployed on a T1 access line at the demarcation point  
between the provider network and customer premises.  
It supports full and fractional (FT1) T1 networks and  
provides connectivity through V.35 interface.  
The ASE supports Multi-Protocol software for deploy-  
ment in standard frame relay or HDLC networks and  
IP Transport software for deployment in networks that  
use IP switching.  
• Inband management capabilities  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Drop-and-Insert capabilities through  
DSX port  
In addition to performing standard CSU/DSU  
functions—such as BER tests, loopbacks, and power  
failure detection—the ASE is capable of inserting  
management traffic.  
• Internal modem  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Power loss detection  
• Realtime events  
T1 CSU/DSU model 807-0111 front view  
T1 CSU/DSU model 807-0111 rear view  
CSU/DSU  
ASE  
T1 Access  
Line  
V.35  
Line  
Wide Area  
Network  
Visual  
UpTime  
Select  
Modem  
Connection  
Optional LAN  
Connection  
PBX  
PBX  
h
Server  
T l  
T1 CSU/DSU model 807-0111 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
T1 CSU/DSU ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)  
Plastic case with internal power supply.  
General  
Weight  
2.10 lbs.  
Data Rate  
Timing Mode  
1.544 Mbps synchronous  
Derived externally from the T1 network or DSX-1  
interface, or internally from the ASE.  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90%, noncondensing  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Operating and Storage  
Humidity  
Input  
100 to 120 VAC  
Power Requirements  
T1 Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Line Rate  
0.5 amps  
1.544 Mbps 50 bps synchronous  
AMI or B9ZS line coding  
ESF or D4 framing formats  
ANSI T1.403, AT&T TR54016, Both, or None  
0dB to -36dB  
Line Format  
Framing  
ESF FDL  
Hardware Warranties  
Input Signal  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Output Signal  
Pulse Density  
Connector  
0, -7.5dB, -15dB, -22.5dB LBO  
AT&T 62411  
8-pin modular jack—USOC: RJ48C  
Loop, DSX-1, or Internal  
1 to 24 channels in any combination  
DCE for interfacing with DTE  
ITU-T V.35  
Timing  
Channel Selection  
Configuration  
Data and Clock Leads  
Signaling Leads  
Data Rates  
Network DTE Interface  
(Data Port)  
Ordering Information  
EIA RS-232 (ITU-T V.28)  
56 kbps x N or 64 kbps x N (N = 1 through 24)  
Selectable V.35 data inversion  
Network selected-source timing  
SCT, inverted SCT, SCTE  
RLSD, CTS  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
HDLC Inversion  
Transmit Timing Basis  
Receive Timing Basis  
Receive Line Data Not Valid  
Connector  
Female 34-pin V.35 connector  
Specifications  
19200 or 9600 bps baud rate, 8 data bits no parity,  
1 stop bit, EIA RS-232 DTE electrical format, RJ-45  
connector  
Serial Port Interface  
Bite Rate  
Connector  
Connector  
Standard  
10 or 100 Mbps  
8-pin modular jack: RJ-48  
RJ11  
Ethernet 10/100BaseT  
Interface  
Modem  
FCC Part 68 and IC-CS03  
US and Canada  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Compliance  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643374 D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0112  
T1 CSU/DSU ASE  
W i t h D S X - 1 , D r o p - a n d - I n s e r t , a n d M o d e m  
The Visual UpTime® SelectT1 CSU/DSU ASE is  
deployed on a T1 access line at the demarcation point  
between the provider network and customer premises.  
It supports full and fractional (FT1) T1 networks and  
provides connectivity through V.35 and additional  
digital cross connect signal (DSX-1) interfaces.  
The ASE supports Multi-Protocol software for deploy-  
ment in standard frame relay or HDLC networks and IP  
Transport software for deployment in networks that  
use IP switching.  
The ASE’s “drop-and-insert” feature provides a  
Key features  
secondary DSX-1 port that can connect to a Private  
Branch Exchange at a customer’s site. T1 Timeslots  
can be segmented for a PBX on the same circuit  
carrying data traffic (see figure). The ASE’s internal  
modem lets users establish a telephone connection  
to either the ASE’s administrative interface or a pass-  
through connection via the serial port.  
• Inband management capabilities  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Drop-and-Insert capabilities through  
DSX port  
• Internal modem  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Power loss detection  
• Realtime events  
T1 CSU/DSU model 807-0112 front view  
T1 CSU/DSU model 807-0112 rear view  
CSU/DSU  
ASE  
T1 Access  
Line  
V.35  
Line  
Wide Area  
Network  
Visual  
UpTime  
Select  
Modem  
Connection  
Optional LAN  
Connection  
PBX  
PBX  
h
Server  
T l  
T1 CSU/DSU model 807-0112 position on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
T1 CSU/DSU ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)  
Plastic case with internal power supply.  
General  
Weight  
2.10 lbs.  
Data Rate  
Timing Mode  
1.544 Mbps synchronous  
Derived externally from the T1 network or DSX-1  
interface, or internally from the ASE.  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Operating/Storage Humidity  
Input  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90%, noncondensing  
100 to 120 VAC  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Power Requirements  
T1 Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Line Rate  
0.5 amps  
1.544 Mbps 50 bps synchronous  
AMI or B9ZS line coding  
ESF or D4 framing formats  
ANSI T1.403, AT&T TR54016, Both, or None  
0dB to -36dB  
Line Format  
Framing  
ESF FDL  
Hardware Warranties  
Input Signal  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
Output Signal  
Pulse Density  
Connector  
0, -7.5dB, -15dB, -22.5dB LBO  
AT&T 62411  
8-pin modular jack—USOC: RJ48C  
Loop, DSX-1, or Internal  
1 to 24 channels in any combination  
DCE for interfacing with DTE  
ITU-T V.35  
Timing  
Channel Selection  
Configuration  
Data and Clock Leads  
Signaling Leads  
Data Rates  
Network DTE Interface  
(Data Port)  
Ordering Information  
EIA RS-232 (ITU-T V.28)  
56 kbps x N or 64 kbps x N (N = 1 through 24)  
Selectable V.35 data inversion  
Network selected-source timing  
SCT, inverted SCT, SCTE  
RLSD, CTS  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
HDLC Inversion  
Transmit Timing Basis  
Receive Timing Basis  
Receive Line Data Not Valid  
Connector  
Female 34-pin V.35 connector  
1.544 Mbps 50 bps  
Line Rate  
DSX-1 Interface  
Line Format  
AMI or B8ZS  
Framing  
ESF or D4 (SF)  
Input Signal  
-1dB to -11dB  
Line Equalization  
Connector  
0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft  
RJ-45  
Channel Selection  
Specifications  
1 to 24 channels in any combination  
19200 or 9600 bps baud rate, 8 data bits no parity,  
1 stop bit, EIA RS-232 DTE electrical format, RJ-45  
connector  
Serial Port Interface  
N E T W O R K S U P E R V I S I O N  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Bite Rate  
10 or 100 Mbps  
Ethernet 10/100BaseT  
Interface  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
Connector  
8-pin modular jack: RJ-48  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 2643363 D-ENG-N Rev A  
©
Specifications  
RJ11 connector, FCC Part 68 and IC-CS03 standards,  
compliance in US and Canada  
Modem  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Visual UpTime Select  
ASE model 807-0100  
Dual-port Dual-analysis ASE  
T1 CSU/DSU with DSX-1 and Drop-and-Insert capabilities  
The Visual UpTime® SelectDual-port Dual-analysis  
T1 CSU/DSU ASE is deployed on a T1 access line at the  
demarcation point between the provider network and  
customer premises. It supports frame relay/HDLC and  
IP Transport capabilities.  
separate frame relay ports (for example, voice over  
FR1, plus SNA over FR2). In addition, domestic and  
international frame relay services can exist on two  
separate ports on the same access line.  
Key features  
• Inband management capabilities  
• Multi-Protocol or IP Transport software  
• Service Level Agreement (SLA) metrics  
• Drop-and-Insert capabilities through  
DSX port  
In addition to performing standard CSU/DSU  
functions—such as BER tests, loopbacks, and power  
failure detection—the ASE is capable of inserting  
management traffic. Up to 155 PVCs or IP circuits can  
be managed per ASE.  
This unit combines two model 109 T1 CSU/DSU ASEs  
with a built-in connector cable and analyzes data on  
both ports. The unit’s second port can be used for  
a redundant router in the event of primary router  
failure. Multiple traffic types can be concentrated on  
• Voice over IP (VoIP) analysis capability  
• Application analysis capability  
• LMI spoofing  
• LAN management port  
• Second analysis port for redundant  
router, different traffic types  
• Power loss detection  
• Realtime events  
T1 CSU/DSU model 807-0109 front view (ASE model 100 is two model 109 units in a rack mount)  
ASE 2  
ASE 1  
DSX  
T1  
ASE 2 PORT 2  
ASE 1 PORT 1  
T1-DSX Cable (801-0096)  
T1 CSU/DSU model 807-0100 rear view  
Wide Area  
Network  
CSU/DSU  
Dual-port ASE  
Optional LAN  
PBX  
Connection on  
data 1  
DSX-1  
V.35 Ports  
PBX  
data 2  
data 1  
T1 CSU/DSU model 807-0100 on network  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
What are ASEs?  
T1 CSU/DSU ASE specifcations  
ASEs (Analysis Service Elements) are data  
collection and network performance monitor-  
ing hardware devices placed on a wide area  
network (WAN) or Local Area Network (LAN)  
as part of the Visual UpTime Select system,  
which offers in-depth, real-time, and historical  
visibility into the performance of your  
Dimensions  
8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)  
Plastic case with internal power supply.  
General  
Weight  
2.10 lbs.  
Data Rate  
Timing Mode  
1.544 Mbps synchronous  
Derived externally from the T1 network or DSX-1  
interface, or internally from the ASE.  
0o to +40oC (+32o to +104o F)  
-20o to +55oC (-4o to +131o×F)  
Minimum of 3” (7.62 cm) space on sides.  
10% to 90%, noncondensing  
Operating Temperature  
Storage Temperature  
Clearance Requirement  
Environment  
applications infrastructure. In the system,  
data gathered by ASEs is stored in the Visual  
UpTime Select server and displayed and ana-  
lyzed from the Visual UpTime Select Web client.  
As a service level management tool, ASEs  
indicate when services are being met, provide  
warnings when services start to degrade, and  
send alerts when services are not met.  
Operating and Storage  
Humidity  
Input  
100 to 240 VAC  
Power Requirements  
T1 Network Interface  
Frequency  
50/60 Hz  
Input Current Rating  
Line Rate  
0.5 amps  
1.544 Mbps 50 bps synchronous  
AMI or B9ZS line coding  
ESF or D4 framing formats  
ANSI T1.403, AT&T TR54016, Both, or None  
0dB to -36dB  
Line Format  
Framing  
ESF FDL  
Hardware Warranties  
Input Signal  
Output Signal  
Pulse Density  
Connector  
Enhanced Gold, Bronze, and International  
Gold ASE hardware warranty service programs  
are available to help you maximize your  
investment in Visual UpTime Select. For more  
detailed warranty information, visit:  
0, -7.5dB, -15dB, -22.5dB LBO  
AT&T 62411  
8-pin modular jack—USOC: RJ48C  
Loop, DSX-1, or Internal  
1 to 24 channels in any combination  
DCE for interfacing with DTE  
ITU-T V.35  
Timing  
Channel Selection  
Configuration  
Data and Clock Leads  
Signaling Leads  
Data Rates  
Network DTE Interface  
(Data Port)  
Ordering Information  
EIA RS-232 (ITU-T V.28)  
56 kbps x N or 64 kbps x N (N = 1 through 24)  
Selectable V.35 data inversion  
Network selected-source timing  
SCT, inverted SCT, SCTE  
RLSD, CTS  
For more details, please contact your Visual  
UpTime Select authorized reseller or  
Fluke Networks Sales at (800) 240-4010  
or (301) 296-2300.  
HDLC Inversion  
Transmit Timing Basis  
Receive Timing Basis  
Receive Line Data Not Valid  
Connector  
Female 34-pin V.35 connector  
1.544 Mbps 50 bps  
Line Rate  
DSX-1 Interface  
Line Format  
AMI or B8ZS  
Framing  
ESF or D4 (SF)  
Input Signal  
Line Equalization  
Connector  
-1dB to -11dB  
0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft  
RJ-45  
Channel Selection  
Specifications  
1 to 24 channels in any combination  
N E T W O R K S U P E R V I S I O N  
19200 or 9600 bps baud rate, 8 data bits no parity,  
1 stop bit, EIA RS-232 DTE electrical format, RJ-45  
connector  
Serial Port Interface  
Fluke Networks  
P.O. Box 777, Everett, WA USA 98206-0777  
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details, go to  
Bite Rate  
Connector  
10 or 100 Mbps  
Ethernet 10/100BaseT  
Interface  
8-pin modular jack: RJ-48  
2006 Fluke Corporation. All rights reserved.  
Printed in U.S.A. 2/2006 264xxxx D-ENG-N Rev A  
©
Download from Www.Somanuals.com. All Manuals Search And Download.  

Edelbrock Automobile Parts 17932 User Manual
Exmark Lawn Mower 4500 461 User Manual
Fisher Price Crib Toy 71985 User Manual
Frigidaire Refrigerator 242063600 User Manual
Frigidaire Washer 134489700A 0501 User Manual
Frymaster Fryer OCF30 User Manual
Garland Food Warmer RHPR 24 User Manual
GBC Time Clock 1774599900 User Manual
GE Air Conditioner AGP07 User Manual
GE Conference Phone 28213 Series User Manual