Chamberlain Garage Door Opener PD210D User Manual

The Chamberlain Group, Inc.  
845 Larch Avenue  
Elmhurst, Illinois 60126-1196  
GARAGE DOOR OPENER  
ASSEMBLY/INSTALLATION MANUAL  
Please read this manual and the enclosed safety materials carefully!  
Fasten the manual near the garage door after installation.  
®
The door WILL NOT CLOSE unless the Protector System is connected  
and properly aligned.  
Periodic checks of the opener are required to ensure safe operation.  
The model number label is located under the light lens on the front panel of  
your opener.  
PD210D • PD212D  
248730  
PD610D • PD612D • 7920KD  
PD612KLD • 48930D  
There are two types of garage door openers pictured. Yours may appear slightly different.  
IMPORTANT SAFETY NOTES  
This garage door opener has been designed and tested to offer safe service provided it is installed, operated,  
maintained and tested in strict accordance with the instructions and warnings contained in this manual.  
When you see these Safety Symbols and Signal Words on  
the following pages, they will alert you to the possibility of  
serious injury or death if you do not comply with the  
warnings that accompany them. The hazard may come  
WARNING  
Mechanical  
from something mechanical or from electric shock. Read  
the warnings carefully.  
WARNING  
Electrical  
When you see this Signal Word on the following pages, it  
will alert you to the possibility of damage to your garage  
door and/or the garage door opener if you do not comply  
with the cautionary statements that accompany it. Read  
them carefully.  
CAUTION  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLANNING  
WARNING  
Identify the type and height of your garage door. If you  
have a one-piece door, follow the assembly  
instructions contained in this manual and refer to the  
Installation Instructions One-Piece Door for  
installation procedures. Survey your garage area to see  
if any of the conditions below apply to your installation.  
Additional materials may be required. You may find it  
helpful to refer back to this page and the accompanying  
illustrations as you proceed with the installation of your  
opener.  
Without a properly working safety reversal system, persons  
(particularly small children) could be SERIOUSLY INJURED or  
KILLED by a closing garage door.  
• The gap between the bottom of the garage door and the floor  
MUST NOT exceed 1/4" (6 mm). Otherwise, the safety  
reversal system may not work properly.  
• The floor or the garage door MUST be repaired to eliminate  
the gap.  
• Do you have an access door in addition to the garage  
door? If not, Model 7702CB Outside Quick Release is  
required. See Accessories page.  
Depending on your requirements, there are several  
installation steps which may call for materials or hardware  
not included in the carton.  
• Look at the garage door where it meets the floor. Any  
gap between the floor and the bottom of the door must  
not exceed 1/4" (6 mm). Otherwise, the safety reversal  
system may not work properly. See Adjustment Step 3.  
Floor or door should be repaired.  
Installation Page 10 – Look at the wall or ceiling above  
the garage door. The header bracket must be securely  
fastened to structural supports.  
Installation Page 12 – Do you have a finished ceiling in  
your garage? If so, a support bracket and additional  
fastening hardware may be required.  
• The opener should be installed above the center of the  
door. If there is a torsion spring or center bearing plate  
in the way of the header bracket, it may be installed  
within 4 feet (1.22 m) to the left or right of the door  
center.  
Installation Page 13 – Do you have a steel, aluminum,  
fiberglass or glass panel door? If so, horizontal and  
vertical reinforcement is required.  
Installation Page 18 – Depending upon garage  
construction, extension brackets or wood blocks may be  
needed to install sensors.  
• If your door is more than 7 feet (2.13 m) high, see rail  
extension kits listed on Accessories page 32.  
Installation Page 18 – Alternate floor mounting of the  
safety reversing sensor will require hardware not  
provided.  
COMPLETED INSTALLATION  
FINISHED CEILING  
Support bracket &  
fastening hardware  
is required.  
See page 12.  
Horizontal and vertical reinforcement  
is needed for lightweight garage doors  
(fiberglass, steel, aluminum, door with  
glass panels, etc.) See page 13 for details.  
Slack in chain tension  
is normal when  
Rail  
garage door is closed.  
Header Wall  
Torsion Spring  
CLOSED POSITION  
Trolley  
Header  
Bracket  
Trolley  
Stop Bolt  
Wall-mounted  
Door Control  
Access  
Door  
Garage  
Center of  
Door  
Garage door  
Chain  
Spring  
Straight  
Door  
Emergency  
Release  
Arm  
Rope & Handle  
Curved  
Door  
Header  
Wall  
Arm  
Door  
Safety  
Garage  
Bracket  
Gap between floor  
Reversing  
Sensor  
Door  
and bottom of door  
Safety Reversing  
must not exceed 1/4"  
Sensor  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS NEEDED  
2 X 4 Board  
Drill  
1/4" Nutdriver  
Wire Cutters  
Drill Bits  
2
1
Carpenter's  
3/16", 5/16"  
and 5/32"  
Level (Optional)  
Pliers  
Tape Measure  
Adjustable End Wrench  
Sockets and Wrench  
1/2", 5/8", 7/16", 9/16"  
and 1/4"  
Stepladder  
Phillips and Flat Screwdriver  
Pencil  
Hack Saw  
Claw Hammer  
Your garage door opener is packaged in one carton which contains the motor unit and the parts illustrated below. Note  
that accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts  
may be stuck in the foam. Hardware for assembly and installation is shown on the next page. Save the carton and  
packing material until installation and adjustment is complete.  
OPENER CONTENTS  
A11  
A20  
CLOSED  
A7  
OPEN  
“U” Bracket  
A9  
Garage Door Monitor  
(Model 7920KD only)  
A5  
A6  
A8  
Rail  
Door  
Center/Back  
Sections (4)  
Control  
All Other  
Models  
A19  
Hanging Brackets  
LOCK  
LIGHT  
Keyless Entry  
A2  
Rail  
Models  
Front (header)  
Section (1)  
PD612KLD (1)  
7920KD (1)  
Straight Door  
Arm Section  
A12  
A3  
A13  
A1  
A14  
Chain Spreader  
with Screws  
Idler Pulley  
Chain and Cable in  
Dispensing Carton  
Curved Door  
Arm Section  
(included with hardware)  
Safety Labels  
and Literature  
Trolley  
Header Bracket  
Models  
Models  
PD210D (1)  
PD610D (1)  
PD612D (2)  
PD612KLD (2)  
48930D (2)  
7920KD (2)  
A4  
A16  
PD212D (2)  
248730 (1)  
Motor Unit with Light Lenses  
(varies depending  
Remote Control Transmitter  
A10  
upon model purchased)  
A15  
A21  
A17  
®
The Protector System  
A18 Assembly and  
Installation Hardware  
(2) Safety Reversing Sensors  
(1 Sending Eye and 1 Receiving Eye)  
with 2-Conductor White and White/Black  
Bell Wire attached  
Safety Sensor  
Bracket (2)  
Door Bracket  
Door Control Button  
Model 248730 ONLY  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASSEMBLY HARDWARE  
Threaded  
B1  
Trolley Shaft (1)  
B7  
Nut 3/8" (1)  
B6  
Bolt 1/4" - 20 x 1-3/4" (2)  
Idler Bolt (1)  
B5  
B3  
B2  
B4  
Lock Nut  
Lock Washer  
3/8" (1)  
1/2" - 20 (2)  
Master Link (2)  
INSTALLATION HARDWARE  
C1  
C4  
C2  
C3  
Lag Screw  
Hex Bolt  
Spacer (2)  
Nut 5/16" - 18 (4)  
C8  
C9  
Rail Grease  
5/16"-18 x 1-7/8" (2)  
5/16"- 18 x 7/8" (4)  
Insulated  
Staples (30)  
C5  
C7  
C11  
C6  
Clevis Pin  
5/16" x 1-1/2" (1)  
Self-Threading Screw  
1/4"-14 x 5/8" (2)  
C10  
Ring  
Clevis Pin  
5/16" x 1-1/4" (1)  
Lock Washer  
5/16" (7)  
Fastener (3)  
C19  
Drywall  
C15  
Screw  
C12  
C18  
Anchors (2)  
C13 Screw 6-32 x 1" (2)  
6AB x 1-1/4" (2)  
Rope  
Carriage Bolts  
C14  
1/4"-20 x 1/2" (2)  
C20  
C17  
C16  
NOTICE  
C21  
Wing Nut  
2-Conductor Bell Wire  
White & White/Red  
Clevis Pin  
Handle (not shown  
actual size)  
1/4 x 20 (2)  
Lag Screw  
5/16" x 1" (1)  
5/16"- 9 x 1-5/8" (2)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASSEMBLY  
CAUTION  
To prevent INJURY from pinching, keep hands and fingers  
away from the joints while assembling the rail.  
Assemble the Rail  
1
As a temporary trolley stop,  
insert a screwdriver into the  
hole 10" (25 cm) away from  
the front of the rail, as shown.  
Idler  
Pulley  
Hole  
A7  
A7  
A7  
A8  
A7  
KEEP SMALL HOLES  
ALONG OPPOSITE EDGE  
OF RAILS  
Window  
Cut-Out  
A13  
As a temporary trolley stop,  
insert a screwdriver into the  
hole 10" (25 cm) away from  
the front of the rail, as shown.  
A8  
10" (25 cm)  
A8  
KEEP LARGER  
HOLE ON TOP  
FRONT RAIL  
(TOP)  
Window  
Cut-Out  
A11 “U” Bracket  
B6 Bolt  
B6 Bolt  
Cover  
Protection  
Bolt Hole  
Trolley  
Stop Hole  
TO MOTOR UNIT  
SLIDE RAIL TO STOPS  
ON TOP AND SIDES  
OF BRACKET  
B3 Lock Nut  
B3 Lock Nut  
Front Rail  
(TO DOOR)  
Back Rails  
(TO MOTOR UNIT)  
A11 “U” Bracket  
ALL HARDWARE SHOWN ACTUAL SIZE  
B6 Bolt  
B3 Lock Nut  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
To avoid serious damage to opener, ONLY use bolts/fasteners  
mounted in top of motor unit.  
Remove Fasteners from  
Top of Motor Unit  
Attach Rail to Motor Unit  
Attach Chain Spreader  
2
3
4
Hex Screws  
8-32x7/16"  
Bolt  
A3  
Bolt  
Chain  
Spreader  
Run Cable Through  
Cut-Out Window  
Install Idler Pulley  
Attach Cable to Front  
of Trolley  
5
6
7
A2  
Bolt  
Chain  
and Cable  
Rail  
Do NOT remove  
Chain/Cable  
from box  
Pulley  
A2 Chain and Cable  
A2 Chain and Cable  
Do NOT remove  
Chain/Cable  
from box  
Nut  
Washer  
B4  
Master Link  
Clip-On Spring  
B5  
Idler Bolt  
A12 Idler Pulley  
Cable  
Loop  
B2  
B4  
Lock Washer  
Master  
Link Bar  
Cable Loop  
B7 Nut  
Cable Loop  
ALL HARDWARE SHOWN ACTUAL SIZE  
B4 Master Link  
B5 Idler Bolt  
B7 Nut  
B3 Lock Nut  
B2 Lock Washer  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
To avoid possible SERIOUS INJURY to fingers:  
• Securely attach chain spreader.  
• NEVER connect garage door opener to power source until  
instructed to do so.  
Route Chain/Cable Around Rail Assembly  
and Motor Unit Sprocket  
8
Leave chain/cable inside  
carton to prevent kinking  
A2  
Chain and  
Cable in  
Dispensing  
Carton  
Cable  
Motor Unit  
Chain  
Sprocket  
Attach Chain To Trolley  
Threaded Shaft  
Attach Nut and Lock  
Washer to Trolley  
Threaded Shaft  
Insert Trolley Threaded  
Shaft into Round Hole in  
Trolley  
9
10  
11  
B4  
Master Link  
Clip-On Spring  
B1  
Trolley  
Threaded  
Shaft  
B1  
B1  
Trolley  
Threaded  
Shaft  
Trolley  
Threaded  
Shaft  
C4  
C5  
Inner Nut  
C6  
Lock  
Lock Washer  
Washer  
C5  
B4  
Outer Nut  
Master  
Link Bar  
Tighten the Chain  
Desired Chain Tension  
12  
A2 Chain  
1/4" (6 mm)  
Base of Rail  
Mid Length of Rail  
Assembly of your opener is now complete.  
ALL HARDWARE SHOWN ACTUAL SIZE  
B1 Threaded Trolley Shaft  
B4 Master Link  
C4 Nut  
C5 Lock Washer  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
IMPORTANT INSTALLATION INSTRUCTIONS  
WARNING  
To reduce the risk of SEVERE INJURY or DEATH:  
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND  
INSTRUCTIONS.  
2. Install garage door opener ONLY on properly balanced and  
lubricated garage door. An improperly balanced door may not  
reverse when required and could result in SEVERE INJURY or  
DEATH.  
3. ALL repairs to cables, spring assemblies and other hardware  
MUST be made by a trained door systems technician BEFORE  
installing opener.  
8. NEVER wear watches, rings or loose clothing while installing  
or servicing opener. They could be caught in garage door or  
opener mechanisms.  
9. Install wall-mounted garage door control:  
• within sight of the garage door  
• out of reach of children at minimum height of 5 feet (1.5 m)  
• away from ALL moving parts of the door.  
10. Place entrapment warning label on wall next to garage door  
control.  
4. Disable ALL locks and remove ALL ropes connected to garage  
door BEFORE installing opener to avoid entanglement.  
11. Place manual release/safety reverse test label in plain view on  
inside of garage door.  
5. Install garage door opener 7 feet (2.13 m) or more above floor.  
6. Mount emergency release handle 6 feet (1.83 m) above floor.  
7. NEVER connect garage door opener to power source until  
instructed to do so.  
12. Upon completion of installation, test safety reversal system.  
Door MUST reverse on contact with a 1-1/2" high (3.8 cm)  
object (or a 2 x 4 laid flat) on the floor.  
One-Piece Door  
Sectional Door  
If you have a one-piece door, proceed to the  
One-Piece Door Installation Instructions included  
with your garage door opener.  
If you have a sectional door, proceed to page 10  
of this manual.  
INSTALLATION  
INSTRUCTIONS  
FOR ONE-PIECE  
DOORS  
PAGE 10  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
WARNING  
To prevent possible SERIOUS INJURY or DEATH:  
• Header bracket MUST be RIGIDLY fastened to structural  
support on header wall or ceiling, otherwise garage door  
might not reverse when required.  
INSTALL THE HEADER BRACKET  
• NEVER try to loosen, move or adjust garage door, springs,  
cables, pulleys, brackets, or their hardware, ALL of which are  
under EXTREME tension.  
NOTE: You can fasten the header bracket within 4 feet  
(1.2 m) of the left or right of the door center only if a  
torsion spring or center bearing plate is in the way; or  
you can attach it to the ceiling when clearance is  
minimal.  
Fasten header bracket securely to structural supports.  
It may be necessary to use a 2 x 4 as a structural  
support if installing on drywall or between two studs as  
shown in Step 3. Securely fasten 2 x 4 to structural  
supports using lag screws (not provided). Concrete  
anchors must be used if mounting header bracket or  
2 x 4 into masonry.  
Mark the Center of the  
Garage Door  
Mark the center of the garage door on door  
and wall and extend onto the ceiling  
1
doorwall a  
Level  
(optional)  
Determine the Highest Point of  
Travel, and Draw Horizontal Line  
for Header Bracket Placement  
Add a 2 x 4 as a Structural Support  
(If Necessary)  
2
3
-In some installations it may be  
necessary to install a 2x4 across  
two studs to create a location for  
header bracket or over drywall  
Mark a spot on the “center of the  
garage door” line, 2" (5 cm) above the  
highest point of travel of the garage door  
2" (5 cm)  
Use lag screws (not provided)  
to secure 2x4 (structural support) into  
wood. Use concrete anchors to secure 2x4  
into masonry.  
Highest Point  
of Travel  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MOUNT THE HEADER BRACKET  
Mark Bracket Holes  
Drill Holes  
Attach Bracket  
4
5
6
Center bracket on the “center  
of garage door” line and the  
horizontal line made in Step 2.  
Drill two 3/16"  
pilot holes  
Secure bracket  
with lag screws  
A14 Bracket  
Mark the top  
and bottom  
UP  
Horizontal Line  
UP  
bracket holes  
C18 Lag Screw  
Highest Point  
of Travel  
Center of  
Garage Door  
Ceiling Mount the Header Bracket (Optional)  
NOTE: If your installation requires that the  
header bracket be mounted to the ceiling. The  
back edge of the bracket MUST NOT be  
further than 6" (15 cm) from the header wall  
and the arrow MUST point away from the  
header wall.  
Center the bracket  
on the “center of  
garage door” line  
A14  
Bracket  
Use holes on  
left and right side  
to secure bracket  
Attach Rail to the Header Bracket  
7
C6  
A14 Header Bracket  
Ring Fastener  
A14  
Ceiling Mount  
Header  
Bracket  
A14  
Header  
Bracket  
C6  
Ring Fastener  
C11  
Clevis Pin  
C11  
Clevis Pin  
Mounting  
Hole  
Existing  
Header Bracket  
Mounting  
Hole  
Existing  
Clevis Pin  
C2  
NOTE: If the door spring  
is in the way, you’ll need  
help. Have someone hold  
the opener securely on a  
temporary support to allow  
the rail to clear the spring.  
Spacer  
Mounting  
Hole  
Garage  
Door  
Option with  
some pre-existing  
installations  
Opener Carton  
ALL HARDWARE  
SHOWN  
ACTUAL SIZE  
C11 Clevis Pin  
C2 Spacer  
C6 Ring Fastener  
C18 Lag Screw  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
To avoid possible SERIOUS INJURY from a falling garage door  
opener, fasten it securely to structural supports of the garage.  
POSITION AND HANG MOTOR UNIT  
Open Door to Full Open Position and Rest Rail  
on a 2x4 to Position Opener at the Proper  
Angle for Hanging from the Ceiling  
1
CAUTION  
To prevent damage to garage door, rest garage door opener  
rail on 2 x 4 placed on top section of door.  
2 x 4  
If the top section or panel hits the trolley when you raise  
the door, pull down on the trolley release arm to  
disconnect inner and outer sections. Slide the outer trolley  
toward the motor unit. The trolley can remain  
disconnected until installation is completed.  
NOTE: The garage door opener motor head will typically  
sit lower than the header bracket, therefore, the rail will be  
at an angle.  
Attach Hanging Brackets to Ceiling and Fasten Motor Unit to Hanging Brackets  
2
NOTE: Before the motor unit is secured to the ceiling, insure that the motor unit and rail are centered  
over the door. If you mounted the header bracket off center, hang the motor unit the same distance.  
Concrete anchors must be used if installing any brackets into masonry.  
Option with finished or unfinished ceiling  
Option with unfinished ceiling  
Bracket  
C8 Lag Screws or  
(Not Provided)  
Concrete Anchors (Not Provided)  
(Not Provided)  
C8 Lag Screws  
Bolt 5/16"-18 x 7/8"  
Lock Washer 5/16"  
OR  
Measure  
Distance  
C9 Hex Bolt  
C5 Lock Washer  
C4 Nut  
Nut 5/16" - 18  
C9 Hex Bolt  
C5 Lock Washer  
C4 Nut  
Remove  
2 x 4  
Remove 2x4 and Close Door  
3
Close door  
ALL HARDWARE SHOWN ACTUAL SIZE  
C8 Lag Screw  
C9 Hex Bolt  
C4 Nut  
C5 Lock Washer  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
To prevent damage to garage door, reinforce inside of door  
with angle iron both vertically and horizontally.  
HORIZONTAL AND VERTICAL REINFORCEMENT  
Horizontal and vertical reinforcement (not provided) is  
needed for light weight garage doors (fiberglass,  
aluminum, steel, doors with glass panel, etc.).  
Top of Door  
Door  
A horizontal reinforcement brace should be long  
enough to be secured to two or three vertical  
supports. A vertical reinforcement brace should cover  
the height of the top panel. Contact your door  
manufacturer for more information regarding  
reinforcement of your door.  
Bracket  
Location  
Hardware  
Door Arm  
(not provided)  
Connects  
Directly to  
Vertical  
Reinforcement  
Many door reinforcement kits provide for direct  
attachment of the clevis pin and door arm. In this  
case, you will not need the door bracket; proceed to  
Connect Door Arm to Trolley section.  
FASTEN THE DOOR BRACKET  
Position Door Bracket  
Mark and Drill 3/16" Holes  
1
2
Position the door bracket on  
the face of the door within the  
following limits:  
1. The top edge of the bracket  
2"-4" (5-10 cm) below the  
top edge of the door.  
2. The top edge of the bracket  
directly below any structural  
support across the top of  
the door.  
C15  
Door Bracket  
Center of  
Garage Door  
Fasten Door Bracket  
3
Metal, insulated or lightweight  
factory reinforced doors  
Wood doors  
Bolt  
5/16" x 2"  
ALL  
HARDWARE  
SHOWN  
(Not Provided)  
OR  
Center of  
ACTUAL SIZE  
Garage Door  
C10 Self-Threading Screw  
UP  
UP  
C10 Self-Threading  
Center of  
Garage Door  
Screws  
NOTE: The 1/4"-14 x 5/8" self-threading screws  
are not intended for use on wood doors.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
To prevent possible SERIOUS INJURY or DEATH from a falling  
garage door:  
• If possible, use emergency release handle to disengage trolley ONLY  
when garage door is CLOSED. Weak or broken springs or  
unbalanced door could result in an open door falling rapidly and/or  
unexpectedly.  
• NEVER use emergency release handle unless garage doorway is  
clear of persons and obstructions.  
ATTACH DOOR TO TROLLEY  
Attach Emergency Release Rope and Handle  
1
Secure handle with overhand knot  
and heat seal rope.  
• NEVER use handle to pull door open or closed. If rope knot  
becomes untied, you could fall.  
ENGAGED  
NOTE: Handle should hang 6 feet (1.5 m) above floor.  
Ensure that the rope and handle clear the tops of all  
vehicles to avoid entanglement.  
C19 Rope  
C20 Emergency  
Release Handle  
Overhand  
Knot  
N
O
T
I
C
E
RELEASED  
CONNECT DOOR ARM TO TROLLEY  
Pull Emergency Release Rope to Disengage  
the Trolley  
Slide Trolley Back 2" (5 cm) and Connect Straight  
Door Arm to the Trolley  
2
3
2" (5 cm)  
C5  
Ring  
Fastener  
Pull Down  
to Release  
Trolley  
Connect  
Straight  
C21  
Door Arm  
Clevis Pin  
to Trolley  
A5  
Straight  
Door Arm  
Connect Curved Door Arm to the Door Bracket  
Ensure Door is Fully Closed and Connect  
Door Arms  
4
5
C6  
Ring  
Fastener  
Connect Curved  
C5  
C4  
Nut  
Door Arm to  
Lock  
Door Bracket  
Washer  
A5  
Straight  
Door Arm  
A1  
Curved  
C7  
Clevis Pin  
Door Arm  
C9 Hex Bolt  
A1  
Curved  
Door Arm  
ALL HARDWARE SHOWN ACTUAL SIZE  
C21 Clevis Pin  
C5 Lock Washer  
C4 Nut  
C9 Hex Bolt  
C6 Ring Fastener  
C7 Clevis Pin  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
To prevent possible SERIOUS INJURY or DEATH from  
electrocution:  
• Be sure power is not connected BEFORE installing Door  
Control.  
INSTALLING THE DOOR CONTROL  
• Connect ONLY to 24 VOLT low voltage circuit.  
To prevent possible SERIOUS INJURY or DEATH from a closing  
garage door:  
• Install Door Control within sight of garage door, out of reach  
of children at a minimum height of 5 feet (1.5 m), and away  
from all moving parts of door.  
• NEVER permit children to operate or play with door control  
push buttons or remote control transmitters.  
• Activate door ONLY when it can be seen clearly, is properly  
adjusted, and there are no obstructions to door travel.  
• ALWAYS keep garage door in sight until completely closed.  
NEVER permit anyone to cross path of closing garage door.  
Strip Door Control  
Connect Wire to  
Door Control  
1
2
Wire  
Strip  
7/16" (11 mm)  
Insulation  
Wire  
A6  
A21  
Door Control:  
Door Control  
White  
Wire  
Multi-Function  
Button  
Terminal  
Screws  
White Wire  
WHT  
2
1
RED  
Red/White  
Wire  
Terminal  
Screws  
Red/White Wire  
Position Door Control, Route Door Control Wire to  
Motor Unit and Secure with Insulated Staples.  
Permanently Mount 2 Safety Labels Using Adhesive  
Backing, Tacks or Staples, If Necessary.  
3
Carefully Remove Cover  
Multi-Function Door  
Controls ONLY  
4
C1  
Insulated  
Door Control  
Wire  
C1  
Staple  
Insulated Staple  
LOCK  
LIGH  
T
5 FEET (1.5 m)  
MINIMUM  
Do NOT strip any  
insulation from  
the staples  
Attach Door Control to Wall and Replace Cover  
5
Connect Door Control Wires  
Multi-Function Door Control  
6
Door Control Button  
Single  
to Motor Unit  
C15  
Red  
C13  
Screw  
Gang Box  
Drywall  
C12  
Screw  
24V Circuit  
Terminal  
Anchors  
Red/White  
White  
Wire  
Terminal  
C15  
C12  
Drywall  
White  
Wire  
Screw  
Anchors  
OR  
LOCK  
LOCK  
LIGHT  
LIGH  
T
C13  
Screw  
C12  
Screw  
9
1
9
1
7
3
7
3
5
5
KG  
KG  
To release or  
insert wire,  
push in tab with  
screwdriver.  
Multi-Function Door Control:  
If, No Gang Box is Present  
Multi-Function Door Control:  
Gang Box Installation  
ALL HARDWARE SHOWN ACTUAL SIZE  
C12 Screw  
C15 Drywall Anchors  
C13 Screw  
C1Staples
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
To prevent possible OVERHEATING of the endpanel or  
light socket:  
• DO NOT use short neck or specialty light bulbs.  
• DO NOT use halogen bulbs. Use ONLY incandescent.  
INSTALLING THE LIGHT BULB(S)  
To prevent damage to the opener:  
• DO NOT use bulbs larger than 100W.  
• ONLY use A19 size bulbs.  
Flex Sides of Light Lens to  
Remove Lens from Tabs  
Rotate Light Lens Down  
Install Standard Light Bulb(s)  
(100W max) into Socket(s)  
1
2
3
100 Watt (Max)  
Standard Light Bulb  
WARNING  
To prevent possible SERIOUS INJURY or DEATH from  
electrocution or fire:  
ELECTRICAL REQUIREMENTS  
• Be sure power is NOT connected to the opener, and  
disconnect power to circuit BEFORE removing cover to  
establish permanent wiring connection.  
Plug Motor Unit into Power Outlet  
1
• Garage door installation and wiring MUST be in compliance  
with ALL local electrical and building codes.  
• NEVER use an extension cord, 2-wire adapter, or change plug  
in ANY way to make it fit outlet. Be sure the opener is  
grounded.  
RIGHT  
WRONG  
NOTE: Plug motor unit into grounded power outlet. If a grounded outlet is not available, contact a qualified  
electrician to install a proper outlet.  
OR  
If permanent wiring is required by your local code, follow procedure below. Disconnect power to the  
circuit before removing cover to establish permanent wiring connections.  
Remove Motor Unit  
Screws and Cover  
Remove Power  
Cord  
Run Wire from  
Outlet to Motor Unit  
Replace Motor Unit  
Cover and Screws  
1
2
3
4
ECTION  
round Tab  
d Wire  
Black  
Wire  
Ground Wire  
Black  
Wire  
White Wire  
Black Wire  
White Wire  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
To prevent SERIOUS INJURY or DEATH from a closing garage  
door:  
• Correctly connect and align the safety reversing sensor. This  
required safety device MUST NOT be disabled.  
®
INSTALL THE PROTECTOR SYSTEM  
• Install the safety reversing sensor so beam is NO HIGHER  
than 6" (15 cm) above garage floor.  
The safety reversing sensor must be connected and  
aligned correctly before the garage door opener will  
move in the down direction.  
NOTE: DO NOT operate the opener at this time.  
IMPORTANT INFORMATION ABOUT THE SAFETY  
REVERSING SENSOR  
If it is necessary to mount the units on the wall, the  
brackets must be securely fastened to a solid surface  
such as the wall framing. Extension brackets (see  
accessories) are available if needed. If installing in  
masonry construction, add a piece of wood at each  
location to avoid drilling extra holes in masonry if  
repositioning is necessary.  
When properly connected and aligned, the sensor will  
detect an obstacle in the path of its electronic beam. The  
sending eye (with an amber indicator light) transmits an  
invisible light beam to the receiving eye (with a green  
indicator light). If an obstruction breaks the light beam  
while the door is closing, the door will stop and reverse to  
full open position, and the opener lights will flash 10 times.  
The invisible light beam path must be unobstructed. No  
part of the garage door (or door tracks, springs, hinges,  
rollers or other hardware) may interrupt the beam while  
the door is closing.  
The units must be installed inside the garage so that the  
sending and receiving eyes face each other across the  
door, no more than 6" (15 cm) above the floor. Either can  
be installed on the left or right of the door as long as the  
sun never shines directly into the receiving eye lens.  
The mounting brackets are designed to clip onto the track  
of sectional garage doors without additional hardware.  
Safety Reversing  
Sensor no higher  
than 6" (15 cm)  
above floor  
Safety Reversing  
Sensor no higher  
than 6" (15 cm)  
above floor  
Invisible Light Beam  
Protection Area  
Facing the door from inside the garage  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
INSTALL THE PROTECTOR SYSTEM  
Assemble Safety Reversing Sensors  
Mount Brackets  
1
2
Garage door track installation (preferred)  
A17  
Safety Reversing  
Sensor  
Door  
Track  
Indicator  
Lens Light  
A17  
Safety Reversing  
Sensor  
C14  
Carriage  
Sensor Beam  
No Higher  
Bolts  
Than 6" (15cm)  
Above Floor  
A10  
Safety Sensor  
C14  
Wing Nut  
Bracket  
Mount Brackets: Mounting Options  
Floor installation (optional)  
Wall installation (optional)  
Wall installation with Extension  
Brackets (optional)  
2a  
2b  
2c  
A9  
Inside Garage Wall  
Extension Bracket  
Inside  
arage  
l
G
Attach with  
(Provided with  
Fasten 2x4 to  
al  
W
concrete anchors  
(not provided)  
Extension Bracket)  
Wall with Lag  
Screws (Not  
Provided)  
OR  
OR  
Sensor Beam  
No Higher Than  
6" (15 cm)  
Sensor Beam  
Sensor Beam  
No Higher  
No Higher  
Than 6" (15 cm)  
Above Floor  
Than 6" (15 cm)  
Above Floor  
Above Floor  
Lag Screws  
(Provided with  
(Not Provided)  
Extension Bracket)  
NOTE: The safety reversing sensor must  
be connected and aligned correctly before  
the garage door opener will move in the  
down direction.  
Safety Reversing Sensors  
MUST be aligned and no  
higher than 6" (15 cm)  
above floor  
Safety Reversing Sensors  
MUST be aligned and no  
higher than 6" (15 cm)  
above floor  
ALL HARDWARE SHOWN ACTUAL SIZE  
C16 Wing Nut  
C14 Carriage Bolt  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRE SAFETY REVERSING SENSOR  
Run Safety Sensor Wire to Motor Unit and Secure  
with Insulated Staples  
3
C1  
Safety Sensor Wire  
Insulated Staple  
Safety Sensor Wire  
C1  
C1  
Insulated Staple  
Insulated Staple  
Do NOT strip any  
insulation from  
the staples  
Safety Reversing Sensor  
S
Safety Reversing Sensor  
Strip All Safety Sensor  
Wires  
Separate the Black/White  
and the White Wires  
Twist Like Colored Wires  
Together  
4
5
6
Strip  
7/16" (11 mm)  
Insulation  
Wire  
Black/White  
Wire  
White  
Wire  
Black/White  
Wires  
White  
Wires  
Connect Safety Sensors to Motor Unit  
7
Locate the quick connect terminals  
on your garage door opener, they are  
located on back panel.  
Insert the two white wires into the white  
quick connect terminal and insert the  
two black/white wires into the grey quick  
connect terminal  
White  
Wires  
Black/White  
Wires  
Grey  
ALL HARDWARE SHOWN  
ACTUAL SIZE  
Terminal  
KG  
KG  
C1 Staples  
Screwdriver  
White  
Terminal  
To release or insert wire,  
push in tab with screwdriver.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
ADJUSTMENT  
Without a properly installed safety reversal system, persons  
(particularly small children) could be SERIOUSLY INJURED or  
KILLED by a closing garage door.  
• Incorrect adjustment of garage door travel limits will interfere  
with proper operation of safety reversal system.  
• If one control (force or travel limits) is adjusted, the other  
control may also need adjustment.  
• After ANY adjustments are made, the safety reversal system  
must be tested. Door must reverse on contact with 1-1/2"  
(3.8 cm) high object (or 2 x 4 laid flat) on floor.  
ADJUSTMENT STEP 1  
ADJUST THE UP AND DOWN TRAVEL LIMITS  
Limit adjustment settings regulate the points at which the  
door will stop when moving up or down.  
To operate the opener, press the door control push bar.  
Run the opener through a complete travel cycle.  
• Does the door open and close completely?  
CAUTION  
• Does the door stay closed and not reverse  
unintentionally when fully closed?  
To prevent damage to vehicles, be sure fully open door  
provides adequate clearance.  
If your door passes both of these tests, no limit  
adjustments are necessary unless the reversing test fails  
(see Adjustment Step 3).  
Cover Protection Bolt  
Adjustment procedures are outlined below. Read the  
procedures carefully before proceeding to Adjustment Step  
2. Use a screwdriver to make limit adjustments. Run the  
opener through a complete travel cycle after each  
adjustment.  
2-4"  
(5 cm-  
10 cm)  
NOTE: Repeated operation of the opener during  
adjustment procedures may cause the motor to overheat  
and shut off. Simply wait 15 minutes and try again.  
NOTE: If anything interferes with the door’s upward travel,  
it will stop. If anything interferes with the door’s downward  
travel (including binding or unbalanced doors), it will  
reverse.  
Limit Adjustment Screws  
Left Side Panel  
ADJUSTMENT LABEL  
HOW AND WHEN TO ADJUST THE LIMITS  
Turn either limit adjustment screw the direction  
of the arrow to increase trolley travel, turn in  
the opposite direction to decrease travel  
If the door does not open completely but opens at  
least 5 feet (1.5 m):  
Increase up travel. Turn the UP limit adjustment screw  
clockwise. One turn equals 2" (5 cm) of travel.  
If the opener reverses in fully closed position:  
NOTE: To prevent the trolley from hitting the cover  
protection bolt, keep a minimum distance of 2-4"  
(5-10 cm) between the trolley and the bolt.  
Decrease down travel. Turn the DOWN limit adjustment  
screw clockwise. One turn equals 2" (5 cm) of travel.  
If the door reverses when closing and there is no  
visible interference to travel cycle:  
If door does not open at least 5 feet (1.5 m):  
Adjust the UP (open) force as explained in Adjustment  
Step 2.  
If the opener lights are flashing, the Safety Reversing  
Sensors are either not installed, misaligned, or  
obstructed.  
If the door does not close completely:  
Increase down travel. Turn the DOWN limit adjustment  
screw counterclockwise. One turn equals 2" (5 cm) of  
travel.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Without a properly installed safety reversal system, persons  
(particularly small children) could be SERIOUSLY INJURED or  
KILLED by a closing garage door.  
ADJUSTMENT STEP 2  
• Too much force on garage door will interfere with proper  
operation of safety reversal system.  
ADJUST THE FORCES  
• NEVER increase force beyond minimum amount required to  
close garage door.  
• NEVER use force adjustments to compensate for a binding or  
sticking garage door.  
Force adjustment controls are located on the back panel  
of the motor unit. Force adjustment settings regulate the  
amount of power required to open and close the door.  
If the forces are set too light, door travel may be  
interrupted by nuisance reversals in the down direction  
and stops in the up direction. Weather conditions can  
affect the door movement, so occasional adjustment may  
be needed.  
• If one control (force or travel limits) is adjusted, the other  
control may also need adjustment.  
• After ANY adjustments are made, the safety reversal system  
must be tested. Door must reverse on contact with 1-1/2"  
(3.8 cm) high object (or 2 x 4 laid flat) on floor.  
The maximum force adjustment range is about 3/4 of a  
complete turn. Do not force controls beyond that point.  
Turn force adjustment controls with a screwdriver.  
NOTE: If anything interferes with the door’s upward travel,  
it will stop. If anything interferes with the door’s downward  
travel (including binding or unbalanced doors), it will  
reverse.  
Force Adjustment  
Controls  
HOW AND WHEN TO ADJUST THE FORCES  
KG  
KG  
1. Test the DOWN (close) force  
• Grasp the door bottom when the door is about halfway  
through DOWN (close) travel. The door should reverse.  
Reversal halfway through down travel does not  
guarantee reversal on a 1-1/2" (3.8 cm) obstruction. See  
Adjustment Step 3, page 22. If the door is hard to  
hold or doesn’t reverse, decrease the DOWN (close)  
force by turning the control counterclockwise. Make  
small adjustments until the door reverses normally. After  
each adjustment, run the opener through a complete  
cycle.  
Back Side Panel  
FORCE ADJUSTMENT LABEL  
9
9
1
1
7
7
3
3
5
5
If the door reverses during the down (close) cycle  
and the opener lights aren’t flashing, increase DOWN  
(close) force by turning the control clockwise. Make  
small adjustments until the door completes a close  
cycle. After each adjustment, run the opener through a  
complete travel cycle. Do not increase the force beyond  
the minimum amount required to close the door.  
KG  
KG  
Open Force  
Force Settings:  
1 = Lowest Force  
9 = Maximum Force  
Close Force  
2. Test the UP (open) force  
• Grasp the door bottom when the door is about halfway  
through UP (open) travel. The door should stop. If the  
door is hard to hold or doesn’t stop, decrease UP  
(open) force by turning the control counterclockwise.  
Make small adjustments until the door stops easily and  
opens fully. After each adjustment, run the opener  
through a complete travel cycle.  
If the door doesn’t open at least 5 feet (1.5 m),  
increase UP (open) force by turning the control  
clockwise. Make small adjustments until door opens  
completely. Readjust the UP limit if necessary. After  
each adjustment, run the opener through a complete  
travel cycle.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Without a properly installed safety reversal system, persons  
(particularly small children) could be SERIOUSLY INJURED or  
KILLED by a closing garage door.  
ADJUSTMENT STEP 3  
• Safety reversal system MUST be tested every month.  
• If one control (force or travel limits) is adjusted, the other  
control may also need adjustment.  
TEST THE SAFETY REVERSAL SYSTEM  
Test  
• After ANY adjustments are made, the safety reversal system  
must be tested. Door must reverse on contact with 1-1/2"  
(3.8 cm) high object (or 2 x 4 laid flat) on the floor.  
• With the door fully open, place a 1-1/2" (3.8 cm) board  
(or a 2 x 4 laid flat) on the floor, centered under the  
garage door.  
• Operate the door in the down direction. The door must  
reverse on striking the obstruction.  
Adjust  
• If the door stops on the obstruction, it is not traveling far  
enough in the down direction. Increase the down travel  
by turning the DOWN limit adjustment screw  
counterclockwise 1/4 turn.  
NOTE: On a sectional door, make sure limit adjustments  
do not force the door arm beyond a straight up and  
down position. See page 14.  
1-1/2" (3.8 cm) board (or a 2x4 laid flat)  
• Repeat the test.  
• When the door reverses on the 1-1/2" (3.8cm) (or a 2x4  
laid flat) board, remove the obstruction and run the  
opener through 3 or 4 complete travel cycles to test  
adjustment.  
®
TEST THE PROTECTOR SYSTEM  
• Press the remote control push button to open the door.  
• Place the opener carton in the path of the door.  
WARNING  
Without a properly installed safety reversing sensor, persons  
(particularly small children) could be SERIOUSLY INJURED or  
KILLED by a closing garage door.  
• Press the remote control push button to close the door.  
The door will not move more than an inch, and the  
opener lights will flash.  
The garage door opener will not close from a remote if the  
indicator light in either sensor is off (alerting you to the fact  
that the sensor is misaligned or obstructed).  
If the opener closes the door when the safety reversing  
sensor is obstructed (and the sensors are no more than  
6" (25 mm) above the floor), call for a trained door  
systems technician.  
Safety Reversing Sensor  
Safety Reversing Sensor  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
IMPORTANT SAFETY INSTRUCTIONS  
WARNING  
To reduce the risk of SEVERE INJURY or DEATH:  
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.  
9. If one control (force or travel limits) is adjusted, the other  
control may also need adjustment.  
10. After ANY adjustments are made, the safety reversal system  
MUST be tested.  
2. ALWAYS keep remote controls out of reach of children. NEVER  
permit children to operate or play with garage door control  
push buttons or remote controls.  
3. ONLY activate garage door when it can be seen clearly, it is  
properly adjusted, and there are no obstructions to door travel.  
4. ALWAYS keep garage door in sight until completely closed. NO  
ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.  
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPEN  
DOOR.  
6. If possible, use emergency release handle to disengage trolley  
ONLY when garage door is CLOSED. Weak or broken springs  
or unbalanced door could result in an open door falling rapidly  
and/or unexpectedly.  
11. Safety reversal system MUST be tested every month. Garage  
door MUST reverse on contact with 1-1/2" (3.8 cm) object  
(or a 2 x 4 laid flat) on the floor.  
12. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED (see  
page 2). An improperly balanced door may NOT reverse  
when required and could result in SEVERE INJURY or  
DEATH.  
13. ALL repairs to cables, spring assemblies and other hardware,  
ALL of which are under EXTREME tension, MUST be made  
by a trained door systems technician.  
14. ALWAYS disconnect electric power to garage door opener  
BEFORE making ANY repairs or removing covers.  
7. NEVER use emergency release handle unless garage doorway  
is clear of persons and obstructions.  
8. NEVER use handle to pull garage door open or closed. If rope  
knot becomes untied, you could fall.  
15.  
SAVE THESE INSTRUCTIONS.  
USING YOUR GARAGE DOOR OPENER  
6. If obstructed while opening, the door will stop.  
7. If fully open, the door will not close when the safety  
sensor beam is broken. The safety sensor has no effect  
in the opening cycle.  
Your Security® opener and hand-held remote control  
have been factory-set to a matching code which changes  
with each use, randomly accessing over 100 billion new  
codes. Your opener will operate with up to eight  
Security® remote controls and one Security® Keyless  
Entry System. If you purchase a new remote, or if you  
wish to deactivate any remote, follow the instructions in  
the Programming section.  
If the safety sensor is not installed, or is misaligned, the  
door won’t close from a hand-held remote. However, you  
can close the door with the Door Control, the Outside  
Keylock, or Keyless Entry, if you activate them until down  
travel is complete. If you release them too soon, the door  
will reverse.  
Activate your opener with any of the following:  
The opener lights will turn on under the following  
conditions: when the opener is initially plugged in; when  
power is restored after interruption; when the opener is  
activated.  
The hand-held Remote Control: Hold the push button  
down until the door starts to move.  
The wall-mounted Door Control: Hold the push button or  
bar down until the door starts to move.  
They will turn off automatically after 4-1/2 minutes or  
provide constant light when the Light feature on the  
Multi-Function Door Control is activated. Bulb size is A19.  
Bulb power is 100 watts maximum.  
The Keyless Entry (See Accessories): If provided with  
your garage door opener, it must be programmed before  
use. See Programming.  
Security® light feature: Lights will also turn on when  
someone walks through the open garage door. With a  
Multi-Function Door Control, this feature may be turned off  
as follows: with the opener lights off, press and hold the  
light button for 10 seconds, until the light goes on, then off  
again. To restore this feature, start with the opener lights  
on, then press and hold the light button for 10 seconds  
until the light goes off, then on again.  
When the opener is activated (with the safety  
reversing sensor correctly installed and aligned)  
1. If open, the door will close. If closed, it will open.  
2. If closing, the door will reverse.  
3. If opening, the door will stop.  
4. If the door has been stopped in a partially open position,  
it will close.  
5. If obstructed while closing, the door will reverse. If the  
obstruction interrupts the safety sensor beam, the  
opener lights will blink for five seconds.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING THE WALL-MOUNTED DOOR CONTROL  
CARE OF YOUR OPENER  
Push  
Bar  
The Multi-Function Door Control  
Limit and Force Adjustments  
LIMIT CONTROLS  
Lock  
Press the push bar/push button to open or  
close the door. Press again to reverse the  
door during the closing cycle or to stop the  
door while it’s opening.  
Weather conditions may cause some  
minor changes in door operation requiring  
some readjustments, particularly during  
the first year of operation.  
Button  
9
9
1
1
LOCK  
LIGHT  
Light  
7
7
3
3
5
5
Button  
KG  
KG  
Open Force Close Force  
FORCE CONTROLS  
Push  
Button  
Light Feature  
Pages 20 and 21 refer to the limit and  
force adjustments. Only a screwdriver is  
required. Follow the instructions carefully.  
Press the Light button to turn the opener  
light on or off. It will not control the opener  
lights when the door is in motion. If you turn it on and then  
activate the opener, the light will remain on for 4-1/2  
minutes. Press again to turn it off sooner. The 4-1/2 minute  
interval can be changed to  
Repeat the safety reverse test (page 22) after any  
adjustment of limits or forces.  
Maintenance Schedule  
Once a Month  
1-1/2, 2-1/2, or 3-1/2 minutes as follows:  
• Manually operate door. If it is unbalanced or binding, call  
a trained door systems technician.  
1. Press and hold the Lock button until the light blinks  
(about 10 seconds). A single blink indicates that the  
timer is reset to 1-1/2 minutes.  
• Check to be sure door opens and closes fully. Adjust  
limits and/or force if necessary.  
2. Repeat the procedure and the light will blink twice,  
resetting the timer to 2-1/2 minutes.  
• Repeat the safety reverse test. Make any necessary  
adjustments.  
3. Repeat again for a 3-1/2 minute interval, etc., up to a  
maximum of four blinks and 4-1/2 minutes.  
Twice a Year  
• Check chain tension. Disconnect trolley first. Adjust if  
necessary.  
Lock Feature  
Designed to prevent operation of the door from hand-held  
remote controls. However, the door will open and close  
from the Door Control, the Outside Keylock and the  
Keyless Entry Accessories.  
Once a Year  
• Oil door rollers, bearings and hinges. The opener does  
not require additional lubrication. Do not grease door  
tracks.  
To activate, press and hold the Lock button for 2 seconds.  
The push bar light will flash as long as the Lock feature  
is on.  
To turn off, press and hold the Lock button again for  
2 seconds.The push bar light will stop flashing. The Lock  
feature will also turn off whenever the “Learn” button on  
the motor unit panel is activated.  
WARNING  
To prevent possible SERIOUS INJURY or DEATH from a falling  
garage door:  
• If possible, use emergency release handle to disengage  
trolley ONLY when garage door is CLOSED. Weak or broken  
springs or unbalanced door could result in an open door  
falling rapidly and/or unexpectedly.  
TO OPEN THE DOOR MANUALLY  
The door should be fully closed if possible. Pull down on  
the emergency release handle and lift the door manually.  
To reconnect the door to the opener, press the door  
control push bar.  
• NEVER use emergency release handle unless garage  
doorway is clear of persons and obstructions.  
The lockout feature prevents the trolley from reconnecting  
automatically, pull the emergency release handle down  
and back (toward the opener). The door can then be  
raised and lowered manually as often as necessary. To  
disengage the lockout feature, pull the handle straight  
down. The trolley will reconnect on the next UP or DOWN  
operation.  
• NEVER use handle to pull door open or closed. If rope knot  
becomes untied, you could fall.  
Trolley  
Trolley  
Trolley  
Release  
Arm  
Trolley  
Release Arm B9  
(In Manual  
Emergency  
Disconnect  
Position)  
Release Handle B9  
E
C
I
T
O
N
(Down and Back)  
N
O
T
IC  
E
Manual disconnect position  
Lockout position  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HAVING A PROBLEM?  
Bell Wire  
Sending Eye  
Safety Sensor  
(Amber Indicator  
Light)  
Receiving Eye  
Safety Sensor  
(Green Indicator  
Light)  
K
G  
“Learn”  
Button  
LED or  
Diagnostic  
LED  
Safety Reversing Sensor  
1. My door will not close and the light bulbs blink on  
my motor unit: The safety reversing sensor must be  
connected and aligned correctly before the garage  
door opener will move in the down direction.  
5. My lights will not turn off when door is open:  
• The garage door opener is equipped with a security  
light feature. This feature activates the light on  
when the safety sensor beam has been obstructed.  
Refer to Operation section; Using the Wall Mounted  
Door Control, Light Feature.  
• Verify the safety sensors are properly installed,  
aligned and free of any obstructions. Refer to  
Installation Step, Install The Protector System®.  
6. My motor unit hums briefly:  
• Check diagnostic LED for flashes on the motor unit  
then refer to the Diagnostic Chart on the following  
page.  
• First verify that the trolley is against the stop bolt.  
• Release the door from the opener by pulling the  
Emergency Release Rope.  
2. My remotes will not activate the door:  
• Manually bring the door to a closed position.  
• Verify your Multi-Function door control is not  
blinking. If it is blinking, deactivate the Lock Mode  
following the instructions for Using the  
Multi-Function Door Control.  
• Loosen the chain by adjusting the outer nut 4 to 5  
turns. This relieves the tension.  
• Run the motor unit from the remote control or door  
control. The trolley should travel towards the door  
and stop. If the trolley re-engages with the door,  
pull the Emergency Release Rope to disengage.  
• Reprogram remotes following the programming  
instructions. Refer to Programming.  
• If remote will still not activate your door, check  
diagnostic LED for flashes on motor unit then refer  
to Diagnostic Chart on the following page.  
• Decrease the up travel by turning the UP Travel  
adjustment screw 2 full turns away from the arrow.  
• If the trolley does not move away from the bolt,  
repeat the steps above.  
3. My door reverses for no apparent reason: Repeat  
safety reverse test after adjustments to force or travel  
limits. The need for occasional adjustment for the  
force and limit settings is normal. Weather conditions  
in particular can affect door travel.  
7. My motor unit clicks:  
• Motor is overheated. Allow 15 minutes for motor to  
cool and try again.  
• Manually check door for balance or any binding  
problems.  
• Refer to Adjustment Step 2, Adjust the Forces.  
4. My door reverses for no apparent reason after  
fully closing and touching the floor: Repeat safety  
reverse test after adjustments to force or travel limits.  
The need for occasional adjustment for the force and  
limit settings is normal. Weather conditions in  
particular can affect door travel.  
• Refer to Adjustment Step 1, Adjust the UP and  
DOWN Travel Limits. Decrease down travel by  
turning DOWN limit adjustment screw clockwise.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIAGNOSTIC CHART  
Your garage door opener is programmed with  
self-diagnostic capabilities. The “Learn” button/diagnostic  
LED will flash a number of times then pause signifying it  
has found a potential issue. Consult the Diagnostic  
Chart below.  
Bell Wire  
Diagnostics  
Located On  
Motor Unit  
KG  
KG  
Installed Safety  
LED or  
Diagnostic  
LED  
Reversing Sensor  
“Learn”  
Button  
Safety Reversing Sensor  
1 FLASH  
Symptom: One or both of the Indicator lights on the safety sensors do  
not glow steady.  
Safety reversing  
sensors wire shorted  
or black/white wire  
reversed.  
• Inspect sensor wires for a short (staple in wire), correct wiring polarity  
(black/white wires reversed), broken or disconnected wires, replace/attach  
as needed.  
• Disconnect all wires from back of motor unit.  
OR  
2 FLASHES  
• Remove sensors from brackets and shorten sensor wires to 1-2 ft  
(30-60 cm) from back each of sensor.  
• Reattach sending eye to motor unit using shortened wires. If sending eye  
indicator light glows steadily, attach the receiving eye.  
Safety reversing  
sensors wire open  
(broken or  
• Align sensors, if the indicator lights glow replace the wires for the sensors. If  
the sensor indicator lights do not light, replace the safety sensors.  
disconnected).  
3 FLASHES  
Symptom: LED is not lit on door control.  
• Inspect door control/wires for a short (staple in wire), replace as needed.  
Door control or  
wire shorted.  
• Disconnect wires at door control, touch wires together. If motor unit  
activates, replace door control.  
• If motor unit does not activate, disconnect door control wires from motor  
unit. Momentarily short across red and white terminals with jumper wire. If  
motor unit activates, replace door control wires.  
• If motor unit doesn’t operate, motor unit is overheated. Wait 15 minutes and  
retry. If motor unit still will not operate replace logic board.  
4 FLASHES  
Symptom: Sending indicator light glows steadily, receiving indicator light  
is dim or flashing.  
Safety Reversing  
Sensors slightly  
misaligned (dim or  
flashing LED).  
• Realign receiving eye sensor, clean lens and secure brackets.  
• Verify door track is firmly secured to wall and does not move.  
5 FLASHES  
Symptom: Motor has overheated; the motor unit does not operate or  
trolley is stuck on stop bolt = Motor unit hums briefly; RPM Sensor =  
Short travel 6-8" (15-20 cm).  
Motor overheated  
or possible RPM  
sensor failure.  
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.  
• If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace  
RPM sensor.  
Unplug to reset.  
6 FLASHES  
Symptom: Motor unit doesn’t operate.  
• Replace logic board because motor rarely fails.  
Motor Circuit Failure.  
Replace Receiver  
Logic Board.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROGRAMMING  
TO ADD OR REPROGRAM AN ADDITIONAL HAND-HELD REMOTE CONTROL  
NOTICE: If this Security® garage door opener is operated with a non-rolling code transmitter, the technical measure in  
the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The  
owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code  
transmitter to circumvent that technical measure.  
Your garage door opener has already been programmed at the factory to operate with your hand-held remote control.  
The door will open and close when you press the push button.  
Below are instructions for programming your opener to operate with additional Security® remote controls.  
Using the “Learn” Button  
Using the Multi-Function Door Control  
9
1
9
1
7
3
7
3
5
5
KG  
KG  
LOCK  
LIGHT  
1. Press and hold the button on the  
hand-held remote* that you wish to  
operate your garage door.  
1. Press and release the “learn” button on  
the motor unit. The learn indicator light  
will glow steadily for 30 seconds.  
2. While holding the remote button, press  
and hold the light button on the  
Multi-Function Door Control.  
LOCK  
LIGHT  
2. Within 30 seconds, press and hold the  
button on the hand-held remote* that  
you wish to operate your garage door.  
3. Continue holding both buttons while you  
press the push bar on the Multi-Function  
Door Control (all three buttons are held).  
3. Release the button when the motor  
unit lights blink. It has learned the  
code. If light bulbs are not installed,  
two clicks will be heard.  
LOCK  
LIGHT  
4. Release buttons when the motor unit  
lights blink. It has learned the code. If  
light bulbs are not installed, two clicks  
will be heard.  
TO CONTROL THE OPENER LIGHTS  
*3-BUTTON REMOTES  
Only available with Multi-Function Door Control:  
If provided with your garage door opener, the large  
button is factory programmed to operate it. Additional  
buttons on any Security®  
In addition to operating the door, you may  
program the remote to operate the lights.  
multi-function remote or  
mini-remote can be  
1. With the door closed, press and hold a  
small remote button that you want to control  
the light.  
programmed to operate  
other Security®  
2. Press and hold the Light button on the Multi-Function  
door control.  
garage door openers.  
3. While holding the Light button, press and hold the Lock  
button on the door control.  
4. After the opener lights flash, release all buttons.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO ADD, REPROGRAM OR CHANGE A KEYLESS ENTRY PIN  
NOTE: Your new Keyless Entry must be programmed to operate your garage door opener.  
Using the “Learn” Button  
Using the Multi-Function Door Control  
LOCK  
LIGHT  
NOTE: This method requires two people if the Keyless  
Entry is already mounted outside the garage.  
1. Press and release the “learn” button  
on motor unit. The learn indicator light  
will glow steadily for 30 seconds.  
1. Enter a four digit personal identification  
number (PIN) of your choice on the  
keypad. Then press and hold enter.  
2. Within 30 seconds, enter a four digit  
personal identification number (PIN) of  
your choice on the keypad. Then press  
and hold the enter button.  
2. While holding the ENTER button, press  
and hold the LIGHT button on the  
Multi-Function Door Control.  
LOCK  
LIGHT  
3. Continue holding the ENTER and LIGHT  
buttons while you press the push bar on  
the Multi-Function Door Control (all three  
3. Release the button when the motor  
unit lights blink. It has learned the  
code. If light bulbs are not installed,  
two clicks will be heard.  
LOCK  
LIGHT  
buttons are held).  
4. Release buttons when the motor unit  
lights blink. It has learned the code. If  
light bulbs are not installed, two clicks  
will be heard.  
TO CHANGE AN EXISTING, KNOWN PIN  
4
5
6
If the existing PIN is known, it may be changed by one  
person without using a ladder.  
PRS  
TUV  
WXY  
7
8
9
QZ  
0
1. Press the four buttons for the present PIN, then press  
and hold the # button.  
ENTER  
The opener light will blink twice. Release the # button.  
2. Press the new 4-digit PIN you have chosen, then  
press Enter.  
The motor unit lights will blink once when the PIN has  
been learned.  
Test by pressing the new PIN, then press Enter. The door  
should move.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO SET A TEMPORARY PIN  
You may authorize access by visitors or service people  
3. To set the number of hours this temporary PIN will work,  
press the number of hours (up to 255), then press .  
with a temporary 4-digit PIN. After a programmed number  
of hours or number of accesses, this temporary PIN  
expires and will no longer open the door. It can be used to  
close the door even after it has expired. To set a  
temporary PIN:  
OR  
3. To set the number of times this temporary PIN will work,  
press the number of times (up to 255), then press #.  
The opener light will blink once when the temporary PIN  
has been learned.  
1. Press the four buttons for your personal entry PIN  
(not the last temporary PIN), then press and hold  
the button.  
Test by pressing the four buttons for the temporary PIN,  
then press Enter. The door should move. If the temporary  
PIN was set to a certain number of openings, remember  
that the test has used up one opening.To clear the  
temporary password, repeat steps 1-3, setting the number  
of hours or times to 0 in step 3.  
The opener light will blink three times. Release the  
button.  
2. Press the temporary 4-digit PIN you have chosen, then  
press Enter.  
The opener light will blink four times.  
One Button Close: Opener can be closed by pressing only the ENTER button if the one button close feature has been  
activated. This feature has been activated at the factory. To activate or deactivate this feature press and hold buttons 1  
and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink four times  
when one button close is deactivated.  
TO ERASE ALL CODES FROM MOTOR UNIT MEMORY  
To deactivate any unwanted remote, first erase all codes:  
Press and hold the “learn” button on motor unit until the  
learn indicator light goes out (approximately 6 seconds).  
All previous codes are now erased. Reprogram each  
remote or keyless entry you wish to use.  
WARNING  
To prevent possible SERIOUS INJURY or DEATH:  
• NEVER allow small children near batteries.  
• If battery is swallowed, immediately notify doctor.  
To reduce risk of fire, explosion or chemical burn:  
THE REMOTE CONTROL BATTERY  
To replace battery, use the  
visor clip or screwdriver blade  
to pry open the case as  
shown. Insert battery positive  
side up (+).  
• Replace ONLY with 3V2032 coin batteries.  
• Do NOT recharge, disassemble, heat above 100°C (212°F) or  
incinerate.  
Battery  
positive  
side up (+)  
Dispose of old battery properly.  
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications  
of this receiver and/or transmitter are prohibited, except for changing the code setting or  
replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.  
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the  
following two conditions: (1) this device may not cause harmful interference, and (2) this  
device must accept any interference received, including interference that may cause  
undesired operation.  
Replace the battery with only  
3V2032 coin cell batteries.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPAIR PARTS  
RAIL ASSEMBLY PARTS  
KEY PART  
NO. NO.  
DESCRIPTION  
1
3
5
2
1
2
3
4
5
6
7
4A1008  
Master link kit  
7
41C5141-1 Complete trolley assembly  
183C158-13 Rail - front (header) section  
183C157-9 Rail - center/back section  
144C56  
41A5807  
12D598-1  
4
Chain idler pulley  
Chain and cable  
“U” bracket  
NOT SHOWN  
183A163  
19A47  
Wear pads  
Cover protection bolt spacer  
6
INSTALLATION PARTS  
KEY PART  
NO. NO.  
DESCRIPTION  
15  
2
1
2
3
4
5
6
41C494-2  
950D  
953D  
10A20  
29B137  
41A2828  
Multi-function door control panel  
Single-button remote control  
3-button remote control  
3V2032 Lithium battery  
Transmitter visor clip  
Emergency release rope and handle  
assembly  
6
4
5
N
O
T
I
C
E
1
3
LOCK  
LIGHT  
7
5
7
8
9
41B4494-1 2-conductor bell wire – white and  
white/red  
41A5047-2 Header bracket with clevis pin and  
fastener  
41A5047-1 Door bracket with clevis pin and  
fastener  
8
10  
9
10  
11  
12  
13  
178B35  
178B34  
12B776  
41A5034  
Curved door arm section  
Straight door arm section  
Hanging bracket  
Safety sensor kit (receiving and  
sending eyes) with 3'(.9 m)  
2-conductor bell wire attached  
11  
12  
13  
14  
14  
15  
41A5266-1 Safety sensor brackets (2)  
41A4166  
Door Control Button  
NOT SHOWN  
41A5258-11 Installation hardware bag  
114A3165  
114A3163  
Assembly/installation manual  
Installation instructions for one-piece  
doors  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MOTOR UNIT ASSEMBLY PARTS  
18  
1
2
3
4
6
17  
6
10  
16  
5
9
7
19  
7
13  
12  
8
15  
14  
(Down)  
Contact  
LIMIT SWITCH  
ASSEMBLY  
Brown  
Wire  
D N  
Grey  
Wire  
U P  
Drive  
Gear  
11  
Center Limit  
Contact  
(Up)  
Contact  
Yellow  
Wire  
KEY PART  
KEY PART  
NO. NO.  
NO.  
NO.  
DESCRIPTION  
DESCRIPTION  
1
2
41A5615  
Chain Spreader  
13  
41D3058 Universal replacement motor and  
bracket assembly  
41C4220A Gear and sprocket assembly  
Complete with: Motor, worm, bracket,  
bearing assembly, RPM sensor  
Complete with: Spring washer, thrust  
washer, retaining ring, bearing plate,  
roll pins (2), drive gear and worm gear, 14  
41A2818 Limit switch drive and retainer  
41A2822-1 Interrupter cup assembly  
41C4398A RPM sensor assembly  
41AC050-1 Receiver logic board assembly  
(PD210D/PD212D/248730)  
helical gear with retainer and grease  
15  
3
41A2817  
41B4245  
Drive/worm gear kit with grease,  
16  
roll pins (2)  
Line cord  
17  
4
5
41A5484-1 End panels with all labels  
(PD610D/PD612D/PD612KLD/7920KD  
41AC050-2 Receiver logic board assembly  
(PD610D/PD612D/PD612KLD/7920KD  
48930D) Complete with: Logic  
board,end panel with all labels, light  
socket  
48930D)  
End panels with all labels  
(PD210D/PD212D/248730)  
41D181  
6
7
8
9
10  
11  
12  
4A1344  
108D79  
30B532  
12A373  
41A3150  
Light socket  
Lens  
1/2 hp Capacitor  
Capacitor bracket  
Terminal block with screws  
18  
19  
41C5497 High voltage wire harness assembly  
41C5498 Low voltage wire harness assembly  
41D180-1 End panels with all labels  
(PD610D/PD612D/PD612KLD/7920KD  
48930D)  
41A5484-1 End panels with all labels  
(PD210D/PD212D/248730)  
41A5525-5 Cover  
41D3452 Limit switch assembly  
NOT SHOWN  
41A2826 Motor shaft bearing kit  
41A2825 Opener assembly hardware kit  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
953D  
7702CB  
SECURITY® 3-Button Remote  
Outside Quick Release:  
Control:  
Required for a garage with NO  
access door.  
Includes visor clip.  
SECURITY® 3-Button Mini  
Remote Control:  
956D  
8 Foot (2.4 m) Rail Extension Kit:  
7708CB  
7710CB  
With key ring and fastening strip.  
To allow an 8 foot (2.4 m) door to  
open fully.  
Motion Detecting Control Panel:  
935CB  
Multi-function door control with motion  
sensor that automatically turns opener  
lights on for 5 minutes when it detects a  
person entering the garage. Sensor can  
be easily deactivated when desired.  
10 foot (3 m) Rail Extension Kit:  
To allow a 10 foot (3 m) door to  
open fully.  
945CB  
940D  
Multi-Function Door Control Panel:  
Extension Brackets:  
41A5281  
Provides a Lock feature which prevents  
operation of garage door opener from  
portable remotes and a Light feature for  
constant light.  
(Optional) For safety sensor  
installation onto the wall or floor.  
To order call: 1-800-528-9131.  
SECURITY® Keyless Entry:  
Enables homeowner to operate garage  
door opener from outside by entering a  
password on a specially designed  
keyboard. Also can add a temporary  
password for visitors or service persons.  
This temporary password can be limited  
to a programmable number of hours or  
entries.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTIES  
CHAMBERLAIN 1 YEAR LIMITED WARRANTY  
6 YEAR MOTOR LIMITED WARRANTY  
PD210D, PD212D, 7920KD & 248730  
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally  
installed, that it is free from defect in materials and/or workmanship for a period of 1 YEAR from the date of purchase and that the MOTOR is free  
from defect in materials and/or workmanship for a period of 6 YEARS from the date of purchase. The proper operation of this product is dependent  
on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions  
will void this limited warranty in its entirety.  
If, during the limited warranty period, this product appears to contain  
a
defect covered by this limited warranty, call  
1-800-528-9131, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair.  
You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt  
with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be  
defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective  
parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.  
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE 1 YEAR LIMITED WARRANTY PERIOD SET FORTH  
ABOVE EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE MOTOR, WHICH ARE LIMITED IN DURATION TO THE 6 YEARS  
LIMITED WARRANTY PERIOD FOR THE MOTOR, AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some  
States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED  
WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE  
(INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE,  
UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR  
REPLACED UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON-RESIDENTIAL USE.  
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR  
HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED  
WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE  
PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.  
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN  
CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF  
WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY.  
NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.  
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not  
apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
CHAMBERLAIN 1 YEAR LIMITED WARRANTY  
LIFETIME MOTOR LIMITED WARRANTY  
PD610D, PD612D, PD612KLD & 48930D  
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally  
installed, that it is free from defect in materials and/or workmanship for a period of 1 YEAR from the date of purchase and that the MOTOR is free  
from defect in materials and/or workmanship for the lifetime of the product. The proper operation of this product is dependent on your compliance  
with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited  
warranty in its entirety.  
If, during the limited warranty period, this product appears to contain  
a
defect covered by this limited warranty, call  
1-800-528-9131, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair.  
You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt  
with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be  
defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective  
parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.  
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE 1 YEAR LIMITED WARRANTY PERIOD SET FORTH  
ABOVE EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE MOTOR, WHICH ARE LIMITED IN DURATION TO THE LIFETIME  
LIMITED WARRANTY PERIOD FOR THE MOTOR, AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some  
States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED  
WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE  
(INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE,  
UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR  
REPLACED UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON-RESIDENTIAL USE.  
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR  
HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED  
WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE  
PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.  
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN  
CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF  
WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY.  
NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.  
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not  
apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
CHAMBERLAIN SERVICE IS ON CALL  
OUR LARGE SERVICE ORGANIZATION  
SPANS AMERICA  
INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE.  
SIMPLY DIAL OUR TOLL FREE NUMBER:  
1-800-528-9131  
For professional installation, parts and service, contact your local CHAMBERLAIN® dealer. Look for him in the  
Yellow Pages or call our Service number for a list of dealers in your area.  
HOW TO ORDER REPAIR PARTS  
Selling prices will be furnished on request, or parts will be shipped at prevailing prices and you will be billed  
accordingly.  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:  
• PART NUMBER  
• PART NAME  
• MODEL NUMBER  
ADDRESS ORDERS TO:  
THE CHAMBERLAIN GROUP, INC.  
Technical Support Group  
6050 S. Country Club Road  
Tucson, Arizona 85706  
SERVICE INFORMATION TOLL FREE NUMBER:  
1-800-528-9131  
© 2008, The Chamberlain Group  
114A3165H  
All Rights Reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Network Hardware NBS008A User Manual
Black Box Stereo Amplifier 1 In 12 Out Audio Video Baseband Amplifier User Manual
Black Decker Cordless Drill BDCDMT112 User Manual
Black Decker Sander 607691 00 User Manual
Bosch Power Tools Drill 1004VSR User Manual
Bose Car Speaker Whippet_OG_SPA User Manual
Broan Vacuum Cleaner VX12000C User Manual
Canon Camera Lens 23569 User Manual
Canon Fax Machine L900 User Manual
Casio Camera Accessories QV 120 User Manual