Bionaire Air Cleaner BAPF29 User Manual

BAP1242/1412/1422CN04EFM2.qxd 3/9/05 11:45 AM Page 1  
5. For the BAP1242, BAP1412 and BAP1422, the filter should  
easily slide onto the filter hang tab with only a small amount of  
pressure. Gently slide the filter onto the rail (See Figure 1).  
PLEASE SAVE THESE  
INSTRUCTIONS  
AIR CLEANER SAFETY  
NOTE: The side with the white filter should face inward.  
6. Replace air inlet grill back onto unit securely.  
DO NOT POINT OUTLET TOWARDS WALL.  
PLEASE READ AND SAVE  
TM  
EnviroKlean air cleaner  
CONSUMER SAFETY INFORMATION  
THESE IMPORTANT SAFETY  
THIS PRODUCT IS EQUIPPED WITH  
A POLARIZED PLUG (a plug having  
one blade wider than the other). This  
plug will fit into the power outlet only  
one way. If the plug does not fit fully  
into the outlet, reverse the plug. If it still  
does not fit, contact qualified personnel  
to install the proper outlet.  
MODEL BAP1242  
BAP1412  
INSTRUCTIONS  
Figure 1  
When using electrical appliances, basic safety precautions should  
always be followed to reduce the risk of fire, electric shock, and  
injury to persons, including the following:  
BAP1422  
Read all instructions before using appliance.  
To avoid fire and shock hazard, plug the air cleaner and  
EnviroCheckTM Wireless Air Quality Center directly into 120V  
AC electrical outlets.  
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS  
POLARIZED PLUG IN ANY WAY.  
The length of the cord used on this product was selected to reduce  
the hazards of becoming tangled in, or tripping over a longer cord. If  
a longer cord is necessary an approved extension cord may be  
used. The electrical rating of the extension cord must be equal to or  
greater than the rating of the air purifier. Care must be taken to  
arrange the extension cord where it cannot be pulled on by children  
or accidentally tripped over.  
If the filter is covered by a bag when shipped: remove plastic  
bag before use.  
Keep the cords out of heavy traffic area. To avoid fire hazard  
NEVER put cords under rugs, near heat registers, radiators,  
stoves or heaters.  
To protect against electrical hazards DO NOT immerse in  
water or other liquids. Do not use near water.  
OPERATING INSTRUCTIONS  
1. Plug into a 120V AC electrical outlet.  
2. Select the desired operating speed. Bionaire® Air Cleaners have  
three speed settings. You can select from HIGH, MEDIUM or  
LOW by moving the switch to the desired setting.  
IONIZER  
Close supervision is necessary when any appliance is used by  
or near children or disabled persons.  
Always unplug the air cleaner or EnviroCheckTM Wireless Air  
Quality Center before moving it, opening the grill, changing  
the filters, cleaning the IR Lens or whenever the appliances  
are not in use. Be sure to pull by the plug and not the cord.  
Your Air Cleaner has an independently controlled ionizer, which,  
when turned on, releases negative ions into outgoing filtered air.  
Ions are tiny particles that carry a positive or negative charge.  
These ions exist naturally around us, in the air, water and ground.  
Both positive and negative ions are colorless, odorless and  
completely harmless.  
3. To release negative ions into the filtered air, move the ionizer  
switch to ON and the light will illuminate.  
NEVER drop or insert any object into any openings.  
4. For optimum air filtration, it is recommended to operate the air  
cleaner continuously. Its rugged motor has been designed to  
give many years of use.  
Negative ions help the air purification process by attaching  
themselves to very small airborne particles in the room. These  
particles take on a negative charge and may join with positively  
charged particles such as dust, pollen, smoke and pet dander to  
form larger particles that are then more readily captured by the  
filter system, or they may be attracted to positively charged  
surfaces like walls or floors.  
Do not operate any appliance with a damaged cord or plug, if  
motor fan fails to rotate, after the appliance malfunctions, or if it  
has been dropped or damaged in any manner. Return appliance  
to manufacturer for examination, electrical or mechanical adjust-  
ment or repair.  
Use appliance only for the intended household use as  
described in this manual. Any other use not recommended by  
the manufacturer may cause fire, electrical shock or injury to  
persons. The use of attachments not recommended or sold  
by The Holmes Group may cause hazards.  
For continuous use, it’s recommended to operate the air cleaner  
at the MEDIUM setting. For quieter operation or use in a  
bedroom, select the LOW setting. When high levels of air  
pollution are present, select the HIGH setting to quickly circulate  
and filter the room air.  
You may also note after extended use, that dust may have  
collected around the grills or front panel. This is from the onization  
affect caused by the negative ions exiting from the air outlet. This is  
additional evidence of the air cleaning effectiveness of negative ions.  
The dust can be easily removed with a clean, damp cloth or soft  
brush.  
CLEANING/MAINTENANCE INSTRUCTIONS  
Cleaning Instructions  
Turn off and unplug the unit before cleaning.  
Do not use outdoors.  
Never block the air openings, or place on soft surface, such  
as bed or sofa, as this could cause the unit to tip over thus  
blocking the air intake opening.  
EnviroCheckTM Wireless Air Quality Center should only be used  
in a room with temperatures between 40° F and 110° F  
1. The outside of the air cleaner can be cleaned with a soft, damp  
cloth.  
NOTE: It is important to replace the filter at the recommended  
intervals. Using the ionizer in conjunction with dirty filters may  
result in dirty particles exiting the air cleaner and being attracted to  
walls, carpets, furniture or other household objects. These dirty  
particles may prove very difficult to remove.  
2. The air inlet grill can be removed and washed in warm soapy  
water (not dishwasher safe). Dry before replacing in the unit.  
Keep appliances away from heated surfaces and open flames.  
3. The top air outlet grill can be cleaned of dust with a small soft  
brush.  
DO NOT attempt to repair or adjust any electrical or mechani-  
cal functions on these appliances. Doing so will void the war-  
ranty. The inside of these appliances contain no user servicea-  
ble parts. All servicing should be performed by qualified per-  
sonnel only.  
WARNING: To reduce the risk of fire or electrical shock, DO  
NOT use these appliances with any solid-state speed control  
device.  
PRE-OPERATING INSTRUCTIONS  
WARNING: Do not allow moisture to come in contact with the  
main housing of the air cleaner.  
1. Carefully unpack your Air Cleaner. Select a firm level place  
where there are no obstructions to the air inlet or filtered air  
outlet. A good location in a room is approximately 1 foot away  
from the wall, in a central location of your home.  
Read instructions before operating.  
Retain for future reference.  
FILTER REPLACEMENT INSTRUCTIONS  
1. Filter Check Indicator – there are two different types of indica-  
tors used in our air purifiers. Your air cleaner may have one of  
the following: a filter condition sticker (for BAP1242, BAP1412  
and BAP1422) that serves as a color coded reference point or  
an indicator light (BAP1422) that illuminates when it is time to  
change the filter.  
Instruction Leaflet  
2. Pull air inlet grill towards you by grasping the finger tabs on  
both sides.  
IN FO-LIN E  
DO NOT place anything on top of these appliances.  
3. Remove filter by gripping on both sides and pulling forward.  
4. Remove protective plastic bag from the filter cartridge.  
If after having read this leaflet, you have any  
questions or com m ents on your air cleaner,  
call 1-8 0 0 -2 5 3 -2 7 6 4 in North Am erica.  
2. Every few weeks, check the condition of the filters.  
3. Remove the air inlet grill. Remove and examine the foam  
pre-filter. If it has collected a noticeable amount of dust or lint,  
remove it from the inlet of the grill and wash it in warm soapy  
water. Rinse and drip dry the pre-filter thoroughly before  
replacing it into the inlet of the grill.  
TWO (2) YEARS FULL WARRANTY  
Figure 2  
Manufacturer warrants for TWO (2) YEARS from the date or  
original purchase, to repair or, if repairs are not commercially  
applicable to replace without charge (parts and labor), any supplied  
or manufactured part of this air cleaner which, upon inspection by  
an authorized service center, proves to have failed in normal use  
due to defects in material or workmanship, or, at its option, to  
replace the unit. If the product can not be reasonably repaired,  
the consumer may elect a free replacement or refund.  
Operations under conditions other than those recommended or  
at voltages other than the voltage indicated on the unit, or any  
attempts by unauthorized personnel to service the unit or modify  
it, will render the guarantee void.  
Manufacturer shall not be liable for any personal injury, property  
damage or any incidental or consequential damages of any kind  
(including water damage), resulting from defects, malfunctions,  
misuse, improper installation or alteration of the product.  
MANUFACTURER EXPRESSLY DISLAIMS ALL REPSONSIBILITY  
FOR CONSEQUENTIAL DAMAGES OR INCIDENTAL LOSSES  
FOR BREACH OF EXPRESS OR IMPLIED WARRANTIES  
CAUSED BY USE OF THIS PRODUCT. SOME STATES DO NOT  
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR  
CONSEQUENTIAL DAMAGE.  
C
E
G
4. With the front grill removed, check the condition of the filter. If  
the filter is dirty, remove the used cartridge and properly dispose  
of it. Do NOT try to wash and re-use the filter. Replace with a  
new filter, removing the protective polybag before inserting into  
the air cleaner.  
NOTE: The side with the white filter should face inward.  
H
J
5. Units which have an indicator light must be reset once the filter  
has been replaced. Reset indicator by inserting a small object  
(such as a pin or paperclip) into the hole marked RESET.  
6. Filter Life – Under normal conditions of continuous use, the  
filter will operate efficiently for 2-3 months.  
Replacement filters are available from your local supplier or by  
calling 1-800-253-2764.  
I
Air Cleaner  
Model #  
Filter Quantity  
Needed  
Filter #  
Filter  
Description  
A
B
BAP1242/  
BAP1412  
General purpose  
& carbon  
General purpose  
& carbon  
BAPF29  
BAPF29  
1
2
The provisions of this warranty are in addition to and not a modifica-  
tion of or subtraction from the statutory warranties and other  
rights and remedies contained in any applicable legislation and to  
the extent that any such provision purports to disclaim, exclude or  
limit any such statutory warranties or other rights or remedies,  
such provisions shall be deemed to be amended to the extent nec-  
essary to comply therewith.  
BAP1422  
D
C
F
G
H
TROUBLESHOOTING  
PROBLEM  
SOLUTION  
For Warranty Service, please call 1-800-253-2764.  
Unit will not operate  
Check to make sure the unit is  
plugged in.  
A Bionaire® customer service representative will help determine  
which is the best procedure in order for your air cleaner to be  
repaired.  
Check to make sure the unit is on by  
turning the power knob to the ON  
position.  
KEEP THIS NUMBER FOR FUTURE REFERENCE  
A
B
Decreased airflow  
Check the filters to see if they are in  
good condition and if they need to be  
changed.  
E
I
Check to ensure nothing is blocking  
air inlet and filtered air outlet.  
SERVICE INSTRUCTIONS  
1. Do NOT attempt to repair or adjust any electrical or mechani-  
cal functions on this unit. Doing so will void the warranty. The  
inside of the unit contains no user serviceable parts. All servic-  
ing should be performed by qualified personnel only.  
2. If you need to exchange the unit, please return it in its original  
carton, with a sales receipt, to the store where you purchased  
it. If you are returning the unit more than 30 days after the  
date of purchase, please see the enclosed warranty.  
3. Should your Air Cleaner require service, please call  
1-800-253-2764 in North America for further assistance.  
If you have any other questions or comments, feel free to  
write to us:  
A.Inlet Grill  
F. Filter indicator Light (For  
BAP1422 only)  
4.  
B.Washable Foam Pre-Filter  
C.Speed Control  
G.Ionizer Control  
H.Ionizer Light  
Consumer Service Department  
32B Spur Drive  
El Paso, TX 79906  
D.Power Indicator(For  
BAP1422 only)  
Bionaire®, the Bionaire logo® and EnviroKlean™ are trademarks of The  
Holmes Group, Inc. or its subsidiary.  
I. EnviroKlean™ Filter  
J. Power Cord  
E.Filtered Air Outlet  
Printed In China  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Staple Gun 9701 User Manual
Blanco Indoor Furnishings 157 073P User Manual
Blue Microphones Headphones 830 User Manual
Briggs Stratton Portable Generator 030212 User Manual
BRK electronic Fire Extinguisher FEBRA2 6 User Manual
Bryant Boiler 234 D User Manual
Canon All in One Printer 4509B061 User Manual
Canon Digital Camera 5169B001 User Manual
Christie Digital Systems Projector LX605 User Manual
Cisco Systems Modem DPC3000 User Manual