Belkin Power Supply Power Supply User Manual

Belkin Power Management Software  
Uninterruptible Power Supply  
Software  
User’s Manual  
For  
Microsoft Windows 98  
Microsoft Windows NT  
Microsoft Windows 2000  
Microsoft Windows Me  
Microsoft Windows XP  
Microsoft Windows 2003  
Linux, FreeBSD  
Download from Www.Somanuals.com. All Manuals Search And Download.  
France  
Belkin SAS Components  
5 rue du Petit Robinson  
78 350 Jouy en Josas • France  
Tel: +33 (0) 1 34 58 14 00  
Fax: +33 (0) 1 39 46 62 89  
European Customer Service/Sales:  
00 800 223 55 460  
European Tech Support:  
00 800 223 55 460  
Germany  
Belkin GmbH  
Hanebergstrasse 2  
80637 • München • Germany  
Tel: +49 (0) 89 143405 0  
Fax: +49 (0) 89 143405 100  
European Customer Service/Sales:  
00 800 223 55 460  
European Tech Support:  
00 800 223 55 460  
The Netherlands  
Belkin B.V.  
Starparc Building • Boeing Avenue 333  
1119 PH Schiphol-Rijk • The Netherlands  
Tel: +31 (0) 20 654 7300  
Belkin Power Management Software  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fax: +31 (0) 20 654 7349  
European Customer Service/Sales:  
00 800 223 55 460  
European Tech Support:  
00 800 223 55 460  
Australia  
Belkin, Ltd.  
7 Bowen Crescent • West Gosford • NSW 2250 Australia  
Tel: +61 (0) 2 4372 8600  
Fax: +61 (0) 2 4372 8603  
Tech Support:  
Australia Toll Free 1800 666 040  
New Zealand Toll Free 0800 441 913  
Singapore Toll Free 800 6161 790  
belkin.com/anz  
China  
Belkin Shanghai Representative Office  
39/F • Shanghai Oriental Center  
No. 31 Wujiang Road  
Shanghai • 200041 • China  
Tel: +86 21-52110808  
Fax: +86 21-52110102  
Tech Support:  
800-820-5816  
Belkin Power Management Software  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Singapore  
Belkin Pte Limited  
9 Temasek Boulevard  
#27-01 Suntec Tower 2  
Singapore 038989  
Tel.: +65 6485 7620  
Fax: +65 6485 7649  
Tech Support:  
Singapore Toll Free 800 616 1790  
Japan Toll Free 00531 12 1409  
Belkin Power Management Software  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
SIMPLE INSTALLATION Windows 98, NT, 2000, Me, XP,2003  
Hardware Installation  
a. Connect the Serial/USB cable to the battery  
backup’s communication port.  
b. Connect the Serial/USB cable to the PC’s  
communication port.  
c. Make sure the communication port selector on the  
back of the battery backup is either on “USB” or  
RS-232 (Serial). Only one communication port can  
be used. Do not connect both USB and Serial at the  
same time.  
Software Installation  
a. Insert the Belkin Power Management Software CD  
to the CD-ROM. The software will display the  
installation menu, or your can select ‘run’ from  
windows start menu and execute ‘setup.exe’.  
Belkin Power Management Software files will be  
copied into the directory you appointed. When the  
software has been launched, the operating system  
will select the local language in the software for  
displaying. If there is no preferred language, the  
Software will default to use English interface.  
b. (Default: C:\Program Files\Belkin\Belkin Power Management  
Software)  
c. After installation. For Windows 95/98, check if there  
is a ‘Rupsmon Daemon’ icon in task bar. For  
Windows NT, go to ‘control panel->service’ and  
check if ‘Rupsmon’ service has started  
d. Click ‘Belkin Power Management Software’ for  
parameter settings.  
e. Click ‘Select UPS’ to monitor local or remote UPS.  
f. Click Settings’ to set ‘Communication Type’ and  
‘Select Comm Port’. If you see ‘Communication  
with UPS’ on the main screen, this means you have  
connected with UPS.  
---For More Parameters, Please Reference Other Topics---  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
SIMPLE INSTALLATION  
Hardware Installation  
Linux, FreeBSD  
a. Connect the Serial cable to the battery backup’s  
communication port.  
b. Connect the Serial cable to the PC’s communication  
port.  
c. Make sure the communication port selector on the  
back of the battery backup is on RS-232 (Serial).  
Software Installation  
a. Log in as the super-user.  
b. Insert Belkin Power Management Software for Unix  
CD in CD-ROM Driver.  
(1) Mount the Belkin Power Management Software for  
Unix CD into Unix file directory '/mnt/cdrom'. For  
instance, in Linux, type:  
# mount -t iso9660 /dev/hdd /mnt/cdrom  
(Please use device name of your system.  
Reference Appendix B for more information.)  
(2) Copy the files in directory '/mnt/cdrom' into '/tmp'  
# cp /mnt/cdrom/unix/* /tmp  
c. Execute the installation program:  
# cd /tmp  
# chmod 555 install  
# ./install  
d. Select the target system from the menu, and  
configuration the Belkin Power Management Software for  
Unix (make sure no other process uses the same serial  
port). the installation program will launch the Belkin  
Power Management Software for Unix daemon process  
automatically.  
---For More Parameters, Please Reference Other Topics.-  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
CONTENTS  
1. Introduction ..........................................................................1  
1.1. Packing including ............................................................2  
1.2. System requirements.......................................................2  
2. Hardware Installation ...........................................................3  
3. Belkin Power Management Software for Windows..............8  
3.1. Features .........................................................................8  
3.2. Software Installation........................................................9  
3.3. Start-up and Uninstall Belkin Power Management Software..9  
3.3.1. Start-up Belkin Power Management Software...........9  
3.3.2. Uninstall Belkin Power Management Software........10  
3.4. Functions ......................................................................11  
3.4.1. UPS dynamic display area .....................................12  
3.4.2. UPS Status Area....................................................12  
3.4.3. Function selection area..........................................12  
4. Belkin Power Management Software for Linux, FreeBSD ......33  
4.1. Features .......................................................................33  
4.2. Software Installation......................................................35  
4.3. Configuration ................................................................38  
4.3.1. Configure Belkin Power Management Software for Unix ..38  
4.3.2. Communication Port ..............................................41  
4.3.3. Community Name and IP Address Configuration ....43  
4.3.4. Event Notice by Email............................................44  
4.3.5. Event Notice by Pager ...........................................44  
4.3.6. Shutdown Batch Job ..............................................46  
4.3.7. Shutdown Command File .......................................46  
4.4. Using Belkin Power Management Software for Unix .......47  
4.4.1. Using the "Belkin Power Management Software" program....47  
4.4.2. Uninstall Belkin Power Management Software for Unix........49  
4.5. Monitor the UPS Status .................................................50  
4.6. Control your UPS ..........................................................55  
4.7. History Information ........................................................57  
4.8. Files List and CD Contents............................................58  
4.9. Instruction to mount CD-ROM........................................58  
4.10.  
4.11.  
System Parameters................................................59  
Belkin Power Management Software FAQ...............59  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
1. Introduction  
Belkin Power Management Software is a smart UPS  
monitoring and controlling software. The software displays  
the status of the UPS (e.g. input & output voltage, line  
frequency, load, temperature and battery capacity) in  
digital and graphic format, which can help you monitor the  
quality of the power supply. Simultaneously, you can  
remotely monitor UPS via network and manage the power  
more effectively. On AC failure or UPS battery low, Belkin  
Power Management Software will perform its monitoring  
function automatically. Belkin Power Management  
Software has some new ways to send the warning  
messages, auto dialing and by e-mail. In addition, the  
software has a new Windows NT service function, which  
allows the monitoring program to be executed  
automatically before log in. The software is available in  
many languages; you can select the one that is most  
familiar for you to carry out the software configuration and  
operation. Today the Internet is widely used, not only for  
PC but also for Server, coming into the times of receiving  
and sending information 24 hours a day. The power  
management without the need for human monitoring has  
been a necessary function of UPS. Belkin Power  
Management Software, with full functions will be the best  
partner of your smart UPS.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
1.1. Packing including  
One Belkin Power Management Software software CD  
One Belkin Power Management Software cable,  
Belkin Power Management Software user’s manual (For  
standard version)  
1.2. System requirements  
Belkin Power Management Software hardware and  
software requirements as follows:  
Computer system RS232 communication port: COM1  
COM4 or USB port.  
Match True RS-232 communication UPS.  
Microsoft Windows 98  
Microsoft Windows NT v4.0  
Microsoft Windows 2000  
Microsoft Windows Me  
Microsoft Windows XP  
Microsoft Windows 2003  
Linux  
FreeBSD  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
2. Hardware Installation  
Please go by the following steps:  
a. Connect the Serial/USB cable to the battery backup’s  
communication port.  
PC  
CABLE  
UPS  
b. Connect the Serial/USB cable to the PC’s  
communication port.  
c. Make sure the communication port selector on the  
back of the battery backup is either on “USB” or  
RS-232 (Serial). Only one communication port can be  
used. Do not connect both USB and Serial at the  
same time.  
d. If the computer has never been connect with a USB  
cable before, then the screen will pop up a small  
window informing you that the new hardware has  
been found and it will automatically setup the system.  
e. If the operating system is Window 98, please follow  
the steps below to install the USB driver.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
1) When connect USB cable to a computer with  
Window 98 system at the first time, it will appears  
the follow window. Please click on ”Next” to  
continue the installation procedures.  
2) Please choose the recommended method by  
Windows to search the USB driver  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3) Please set the USB driver location to start search  
4) Windows has found the USB driver, please click  
“Next” to continue.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
5) Windows has finished installing the USB driver.  
6) Once after execute the above installing  
procedures, please make sure that the “USB  
Human Interface Device” does display under  
“System Properties/ Human Interface Devices”.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
WARNING  
Belkin Power Management Software cable is  
specially design, Do not use any other CABLES to  
connect UPS.  
When select USB interface as communication port,  
only Windows 95/98/NT/2000/Me/XP/2003 workable.  
When disconnection is cause by using the interface  
switch of USB and RS232 directly at the back of the  
UPS, then please replug the USB or RS232 cable  
again for the new connection.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3. Belkin Power Management Software for Windows  
3.1. Features  
Support Windows NT Service function.  
Support multiple shut down.  
Support multiple languages.  
Sending warning message by e-mail automatically.  
Calling pager for the warning message automatically.  
Remote monitoring UPS via TCP/IP or Internet.  
Detect AC fail and UPS battery low automatically.  
Scheduling turn on/off timing.  
Displaying the UPS status at graphic, such as the  
temperature, voltage, load, line frequency etc.  
Broadcasting warning message.  
Setting the countdown timing and the interval of each  
warning.  
Setting UPS diagnostic and self- test time.  
Before removing the system, automatically close and  
store the applicable programs.  
Recording and analyzing the UPS status.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.2. Software Installation  
The SETUP program is required for Belkin Power  
Management Software installation. After installation, the  
files will be copied to the “Belkin\Power Management  
Software” directory.  
Following the steps below:  
a. Turn on UPS and PC.  
b. Place the Belkin Power Management Software CD  
into CD ROM. Belkin Power Management Software  
will display the installation menu, or you can select  
run’ from windows start menu and execute  
setup.exe’.  
c. After installation, Belkin Power Management Software  
files will be copied into the directory you appointed.  
When the software has been launched, the operating  
system will select the local language in the  
software for  
displaying.  
If  
there  
is  
no  
preferred language the software will use English  
interface instead.  
(Default: C:\Program Files\Belkin\Belkin Power  
Management Software)  
3.3. Start-up and Uninstall Belkin Power Management  
Software  
3.3.1. Start-up Belkin Power Management Software  
After installation, please restart the computer. For  
Windows 95/98/Me, check if there is a ‘Rupsmon  
Daemon’ icon in task bar. For Windows NT/2000/XP, go  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
to ‘control panel->service’ and check if ‘Rupsmon’ service  
has started.  
Belkin Power Management  
Software is operating normal  
Belkin Power Management  
Software  
service  
is  
not  
operated or the software cable  
is disconnected  
If you want to change the function configuration, please  
run the Belkin Power Management Software in the task  
bar directly or select "Belkin Power Management Software  
for Windows" from "Belkin Power Management Software"  
in program group of start menu in Windows.  
3.3.2. Uninstall Belkin Power Management Software  
After installation, there are 4 selections as below under  
"Belkin Power Management Software" in Windows start  
menu. If you want to remove the teh software from the  
system, please select "Belkin Power Management  
Software Uninstall".  
Belkin Power Management Software for WindowsEnter  
into Belkin Power Management Software main function  
figure  
Belkin Power Management Software HelpBelkin Power  
Management Software introduction  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Belkin Power Management Software ReadmeBelkin  
Power Management Software simple introduction  
Belkin Power Management Software UninstallRemove  
Belkin Power Management Software from Windows  
system  
3.4. Functions  
After entering Belkin Power Management Software, a  
functional chart displays as below.  
1. UPS dynamic display area (3.4.1)  
2. UPS Status Area (3.4.2)  
3. Function selection area (3.4.3)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.4.1. UPS dynamic display area  
This area displays some relevant information about the  
UPS. Users can select different display mode, such as  
meter, digital, block and chart. The information includes  
input voltage, output voltage, line frequency, battery  
capacity, load, temperature etc.  
3.4.2. UPS Status Area  
After the software is installed, check whether the UPS is  
connected to the computer, and the AC power is in normal  
range. The status of the UPS power supply and some  
relevant information of the UPS are displayed.  
3.4.3. Function selection area  
After a successful installation, you can start to configure  
the parameter value. Each parameter value will affect the  
normal operation of the software program. Please  
configure the parameter value of the different function  
options, according to the following chapter.  
3.4.3.1. Select UPS  
Configure Belkin Power Management Software: Monitor  
local UPS or Monitor remote UPS. The method: press  
"select UPS" for the selection - as shown below.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Monitor Local UPS  
Select monitor local UPS.  
Monitor Remote UPS  
(1) Select monitor remote UPS.  
(2) You can modify or insert the remote UPS data to the  
form and then exit.  
(3) Select the UPS that you want to monitor and control  
in the drop-down menu.  
(4) Start to execute the function to monitor remote UPS.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.4.3.2. Settings  
After selecting a UPS, other parameters may be  
configured on the other Settings dialogue box tabs. If  
parameter values are incorrectly set the software may  
have problems functioning properly.  
Please click on icons listed below to get more information  
for its functions.  
General Settings: Defines location of UPS COM port,  
communication protocol, and sets password for remote  
users.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Computer Shutdown Sequence Settings: Set the  
functions  
you  
want  
to  
execute  
when  
the  
software detects an AC power failure or a UPS  
low-battery.  
Broadcast  
Settings:  
Enable/disable broadcasting  
warning message when Belkin Power Management  
Software detects an AC power failure or a UPS  
low-battery.  
Automatic Shutdown Time Parameters: Set the time  
for Belkin Power Management Software to shutdown  
operating system and UPS when an AC failure or UPS  
low-battery is detected.  
Belkin Power Management Software "Settings" windows:  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
A. General Settings  
Communication Type: RS232/USB  
Select Comm Port: Configure communication port to  
connect with the Belkin Power Management Software  
cable. (COM1-COM4).  
Password: Set the password of the remote connection  
of the Belkin Power Management Software. The  
connection would be successful only if the right  
passwordis provided. The password prevents the UPS  
from unlawful connections from remote computers.  
Record UPS Data: Set the record time interval about  
input & output voltage, line frequency, load, battery  
capacity and temperature.  
B. Computer Shutdown Sequence Settings  
In this section, you can set the functions you want to  
execute when the Belkin Power Management Software  
detects the signal for closing the computer.  
Optional Command File to Execute: Set the file name to  
be executed before the system shutdown. (the full path  
and filename given.)  
Attention:If the program, which you execute, cannot  
quit automatically, you would not be able to  
shutdown Windows and turn off the UPS.  
Auto Save Application Files: Configure auto saving all  
the opened applications and files before the system  
shut down. If not given the filename, Belkin Power  
Management Software will auto save in TMP (e.g.  
~Wnnnn.TMP). Check the closed filename in "Close  
Files Record" in function menu.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Attention: Belkin Power Management Software will  
try to close general applications and store files by  
artificial intelligence mode, but the software cannot  
ensure that all the applicable software will be  
stored normally.  
Shut Down Operating System: Set to shut down it's own  
operating system.  
Turn Off UPS: Set to turn off the UPS power supply.  
Attention: After shutting down system and turning  
off UPS, please do not cut the power supply.  
Otherwise, UPS and computer would fail to start  
automatically when AC power restores.  
Display Closed Files Record on Belkin Power  
Management Software Restart: Display the closed  
record on the software restart if the auto saving function  
was set before closing the computer. Shown as below.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
C. Broadcast Settings  
Enable /disable broadcasting warning message when  
Belkin Power Management Software2000 detects AC  
failure or UPS battery low.  
Enable Pop-Up Warnings: The users can set whether or  
not appear the pop-up warning on the screen when the  
Belkin Power Management Software detected AC  
power failure, UPS battery low or the signal of closing  
the computer. You can use the default message or you  
can set or modify the message on your own.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Enable E-Mail: In this configuration, the messages  
could be sent to the administrator by e-mail. Shown as  
below.  
Sender Display NameSetting name for message  
"Sender".  
Sender Email AddressSetting the email address for  
sending message.  
SMTP Server Address Set-up SMTP mail server  
address by IP or server-name. (e.g. 210.71.130.1 or  
belkin.com)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Server Require AuthenticationSome Email Server  
required authentication by password, user can set the  
password here.  
Notified Email Address Select the event item for  
sending first, and set the email address for receiving  
message. Press “OK” to save all the setting. E-mail may  
be sent in response to different events. More than one  
E-Mail address can be specified in the form of a list  
separated by commas. There is no limit on the number  
of mail recipients.  
Power abnormal condition: All Events/AC Failure/AC  
Power Restored/UPS Battery Low/Recovered from  
Low.  
Please Press "Add/Modify/Delete" button to edit  
email address.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
For sending all events to the same email account,  
select “All Events” and type the receiving email  
address.  
Following picture is the email contents that sent  
automatically by “Belkin Power Management Software”:  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Enable Pager:  
In this function, the users can set the messages to the  
system administrator by pager. The configuration's mode  
and screen is as below.  
Modem connected to: set the communication port,  
which connects with the Modem. The setting value is  
COM1-COM4.  
Event: As listed above. Pager number: Input the  
pager number. If necessary, please input the prefix  
code for outside line first, then add "," for 0.5 second  
delay time, the full pager numbers at last.  
Code to send: you can input the event code for  
sending.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Send Notification to the same pager number :  
Select this check box to send all messages to the  
same pager and enter the relevant pager number in  
the AC Failure field.  
For instance: Set the Modem connect to COM2 and dial  
“0” to access an outside line, and pager number is  
“0,947123456” and "#1234#"means AC power failed.  
(Attention: The action should be done within 20  
seconds from calling pager number to sending code  
transmission.)  
D. Automatic Shutdown Time Parameters  
UPS allows the users some time to shut down the system  
before the UPS battery is exhausted. The characteristic  
configuration of the UPS makes it so the system can be  
restarted and operated normally.  
After AC Failure, Commence Computer Shutdown  
Sequence in: Set the continuous time for system  
operation after AC power fails. Please refer to the UPS  
hardware manual or consult to the UPS supplier before  
your configuration.  
.settings range:0~2880 mins  
.default value:10 mins  
If Low Battery Occurs, Commence Shutdown Sequence  
in: Set some time for system's continuous operation  
when battery low. For the setting value, the smaller is the  
better.  
.settings range:0 ~600 mins  
.default value:1 mins  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Time Needed for Shutdown Sequence Before UPS Turn  
Off: Set time interval from when Windows shutdown to  
UPS power supply turn-off. It should be considered  
whether the time is enough for archiving before the  
system shutdown. The time for archiving would be  
different for the amount and the size of the opened files .  
.settings range0.2 99 mins  
.default value:2 mins  
Pop-Up Warning Message Every: Set the time interval  
for displaying the warning messages.  
.settings range:10~600 secs  
.default value:30 secs  
3.4.3.3. Schedule  
Belkin Power Management Software can set the  
scheduled time for the UPS to turn on /off and self-test.  
Therefore, the system could be operated without the  
management from system supervisor. You can set what  
and how often the schedule execution is. The setting  
category and operating frequency are as below.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Actions  
.Turn on UPS  
.Shutdown Operating System and UPS  
.UPS Self-Test Until Battery Low  
.UPS Self-Test for 10 Secs  
Frequency  
.Once  
.Daily  
.Weekly  
.Monthly  
Setting method: press "Schedule" in function menu. Select  
the date in the upper of left corner, and then press the  
“Add” key for the "schedule configuration". After the action  
and frequency's selection, press "OK" and back to the  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
"Schedule" screen, then the new schedule could be seen  
in the record. If you want to set more records, repeat the  
steps above. After configuration, press "save" for  
archiving or select the item then press, "remove" for taking  
out the record. Shown as below.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.4.3.4. Data Log  
The UPS data could be recorded in this section, such as  
the input and output voltage, line frequency, load, battery  
capacity and temperature etc. The record interval could be  
altered in the area of " Automatic Shutdown Time  
Parameters" in "settings" of the function menu. In the  
section of "Data Log", press "Update" for data refreshing  
and press "Clear" for data deletion. The maximum number  
of data could be recorded in this file is 2000. Shown as  
below.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.4.3.5. Event Log  
You can check the date, time, and description of events in  
Event Log. The maximum number of data could be  
recorded in this file is 2000 entries. Shown as below.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.4.3.6. History Calendar  
In this section, you can check the monthly event, including  
AC fail, battery low, OS and UPS shutdown, UPS self-test  
etc. Different color stands by different category. press the  
block, the specific date will be displayed in the bottom of  
your right hand side. Press "PREV" for last month event  
record. Press "NEXT" for event record of the next month.  
Press the button "Exit" for quitting.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.4.3.7. Control  
Command UPS directly for the following test.  
UPS Self-Test for 10 Secs  
UPS Self-Test Until Battery Low  
Cancel UPS Self-Test  
Shut Down Operating System  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.4.3.8. Closed Files Record  
In this section, you can check the closed applications and  
saved files. Method: select "Closed Files Record" in the  
function menu. It only records the latest saved information.  
Shown as below.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
3.4.3.9. About Belkin Power Management Software  
Clicking on "About" in the Belkin Power Management  
Software main screen displays copyright and version  
information on Belkin Power Management Software.  
3.4.3.10. Exit Belkin Power Management Software  
Select "Exit Belkin Power Management Software" in  
function menu to close the software. (Belkin Power  
Management Software will still execute the monitoring  
function in the background.)  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4. Belkin Power Management Software for Linux, FreeBSD  
4.1. Features  
Power Crisis Management  
Utility Failure and Battery Low Detection  
Programmable System and UPS shutdown delay time  
Automatic system and UPS shutdown on power outages  
or before battery exhaustion  
Warning Messages sent to users at regular intervals  
prior to system shutdown  
Event Messages sent to manager by email or pager  
Unattended and scheduled system shutdown and  
automatic reboot  
User-defined batch job execution before system  
shutdown  
Power event notification for users and administrators  
UPS Management  
UPS Preventive Maintenance - Initiate Self-tests to  
ensure the health of the UPS.  
UPS Battery Conservation – Put a network UPS on  
battery to sleep before the battery becomes depleted.  
Turn on, turn off, reboot or put the UPS to sleep straight  
from your console.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
POWER MANAGEMENT UTILITIES  
Automatic installation procedure.  
Automatic background process initialization on startup  
Real-time graphical display of power/UPS status  
UPS power event logging  
Intuitive Parameter Configuration Editor  
Batch Job Execution before System Shutdown  
Simultaneous monitoring of several remote network  
UPSs  
Automatic Communication Port name detection  
Local monitoring through a cable attached to the  
system’s RS232 serial port  
Local Network UPS monitoring through an SNMP agent  
(MIB OID {iso (1) org (3) dod (6) internet (1) private (4)  
enterprises (1) ppc (935)}  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.2. Software Installation  
1. Log in as the super-user.  
2. Insert Belkin Power Management Software for Unix CD in  
CD-ROM Driver.  
(1) Mount the Belkin Power Management Software for  
Unix CD into Unix file directory '/cdrom'. For instance, in  
Linux, type:  
# mount -t iso9660 /dev/hdd /mnt/cdrom  
(Please use device name of your system. Reference  
4.9 for more information.)  
(2)Copy the files in directory '/mnt/cdrom' into '/tmp'  
# cp /mnt/cdrom/unix/* /tmp  
3.Execute the installation program:  
# cd /tmp  
# chmod 555 install  
# ./install  
The installation program will not execute in some shell scripts.  
If this happens, change to another shell script and try again.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.Select the target system from the menu. Installation program  
will automatically copy files to the default location: "/etc/Belkin"  
and modify the system startup file to contain the Belkin Power  
Management Software for Unix daemon process.  
5.Press [enter]. The configuration set up screen appears.  
Follow instructions in chapter 3 to configure Belkin Power  
Management Software.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
6.After configuration, press [q]. The installation program will  
launch the Belkin Power Management Software for Unix  
daemon process automatically.  
If your system does not have a CD-ROM drive, you could  
use the ‘ftp’ utility in MS-DOS to copy files into the system  
directory ‘/tmp’. Follow the same procedure to install the  
software. If there is no network connection in your system,  
please let your dealer know what kind of media you could  
use to copy files into your system.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.3. Configuration  
4.3.1. Configure Belkin Power Management Software for Unix  
Before using Belkin Power Management Software for  
Unix, make sure the following items are all correct or  
appropriate:  
1. Communication port name (chapter 4.3.2) or  
2. IP Address and Community Name (chapter4.3.3)  
3. Shutdown delay time (chapter 4.3.3)  
4. Event notice by Email (chapter 4.3.4)  
5. Event notice by Pager (chapter 4.3.5)  
6. System shutdown command (chapter 4.3.6)  
Belkin Power Management Software provides a full-screen editor for  
setting the parameters. The function key descriptions are at the  
bottom of the screen. You can type ‘/etc/belkin/belkin config’  
at any time to configure Belkin Power Management Software for  
Unix.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Detailed Description of Each Option :  
[d] System Shutdown Delay Time When AC Power  
Failed:  
This  
is  
the  
allotted time for  
users to save files and logout before the system shutdown  
when utility failure occurs. Belkin Power Management  
Software for Unix will send periodic alerts to users to  
inform them about the impending system shutdown every  
minute based on this setting. When countdown ends, the  
system will be shut down. Maximum value is 24 hours;  
minimum value should not less than the battery low delay  
time.  
[b] System Shutdown Delay Time When Battery Low:  
This is the delay time when a battery low condition occurs  
during power failure countdown. This is usually shorter  
than the utility failure delay time since the UPS battery is  
almost depleted. Minimum value is 1 minute; maximum  
value should not be greater than the delay time when AC  
power fails.  
[u] UPS Turn Off Delay Time:  
This is delay time before the UPS stops providing output  
power. It has to be long enough to make sure the Unix  
system can be shut down completely. The turn off  
command is issued to the UPS at the same time when  
system begins the shutdown process. This delay time can  
be: 0.2, 0.3, … 0.9, 1.0, 2.0, 3.0, …10.0 minutes.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
[k] <<Change UPS Monitoring>>  
Set this value to Monitor UPS from local serial port if the  
UPS providing your computer’s  
power is connected to your  
system’s serial port.  
See chapter 4.3.2 for more information.  
Set this value to Monitor local  
UPS SNMP agent if the UPS  
providing your computer’s power  
is connected to an SNMP agent  
on the network.  
See Chapter 4.3.3 for more information  
[n] Shutdown Count Down Display:  
Set this value to ON if you want users to receive periodic  
alerts before system shutdown. Set this value to OFF if  
otherwise.  
[l] Scheduling Function:  
Set this value to  
ON if you want to  
schedule unattended  
system shutdown  
and automatic reboot. Set this value to OFF if otherwise.  
Setting this value to OFF will also stop an impending  
scheduled system shutdown.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
[a] Turn off UPS after System Shutdown  
Set this value to YES if you want Belkin Power  
Management Software to turn off the UPS after shutting  
down the system. Set this value to NO If you want the  
UPS to continue providing output power until its batteries  
get drained. Belkin Power Management Software would  
not be able to reboot the system automatically if this value  
was set to NO.  
[t] Time Scheduling (hh:mm)  
Set various startup and shutdown times for every day for  
the week. Belkin Power Management Software for Unix  
powers down and reboots the system based on this preset  
weekly schedule. When the scheduled time to shutdown  
approaches, Belkin Power Management Software for Unix  
will send periodic alerts to inform users to save files, close  
jobs and log out of the system.  
[s] Save Configuration.  
Saves all modified parameters.  
[q] Quit.  
Quit configuration without  
saving changes.  
4.3.2. Communication Port  
Set option [k] to Monitor UPS from local serial port if you  
intend to use Belkin Power Management Software to  
monitor a UPS attached to your system’s serial port.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
[c] Communication Port:  
This is the device name of the serial port connected to the  
UPS. The default port name should be right for most  
systems. You can set this to any name that your system  
actually uses. Serial port names differ between each  
operating system. If you are not sure of the correct port  
name, please check your system documentation or refer  
to Appendix B for the correct serial port name.  
Belkin Power Management Software would try to  
auto-detect your Serial Port Name if you happen to enter a  
wrong one. If auto-detection fails then the message “UPS  
Adapter No Response” would appear.  
[v] Battery Rating Voltage (if not provided by UPS):  
This option appears only when UPS monitoring is done  
through the system’s serial port. Set this value only if your  
UPS does not provide this information. You could get this  
value from your UPS operation manual. This value will be  
used to calculate the battery level displayed on the status  
screen.  
Trouble Shoot the Communication Port  
What to do when a "UPS adapter no response" message  
appears after running Belkin Power Management  
Software for Unix. (Linux OS was used as an example).  
Please refer to the system documentation if you do not  
have the same Unix system as serial port setup  
procedures may vary from system to system.  
1. Make sure no other process uses the same serial port.  
2. Turn off function 'getty' of the serial port.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
For Linux OS, check the file ‘/etc/inittab’ for the line  
below, and change ”respawn” to off”:  
ttya:2345:respawn:/sbin/getty 9600 ttyS0  
Com1  
Change this value to “off”  
Execute this command if you modified the ‘/etc/ttytab’ file.  
This will force an initial process that closes and re-opens  
the terminals.  
kill -1 1  
3. Change the file permission of ‘/dev/ttyS0’  
chmod 666 /dev/ttyS0  
4.3.3. Community Name and IP Address Configuration  
Set option [k] to Monitor local UPS SNMP agent if you  
intend to use Belkin Power Management Software to  
monitor a UPS attached to a local SNMP agent. The host  
computer (this computer’s IP address) should have  
read-write access right to the SNMP agent.  
[o] Community Name  
The community name should correspond to a community  
known to the UPS SNMP agent.  
[p] Ip Address  
The target SNMP Agent IP address.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.3.4. Event Notice by Email  
Belkin Power Management Software for Unix provides  
event notice functions. These functions enable you to  
know the newest power events by email or pager(chapter  
4.3.5).  
When power event occurs, Belkin Power Management  
Software will sends necessary message to the email  
address (es) recorded in the file named  
/etc/belkin/belkin.eml  
This is a plain text file, adding any email address in a new  
line will enable Belkin Power Management Software  
sending necessary message to it when power events  
occur. These power events include Utility Fail, Utility  
Recovery, Battery Low and Battery Recovery.  
4.3.5. Event Notice by Pager  
This function is likely to the function of 'Event Notice by  
Email'. When power event occurs, Belkin Power  
Management Software will try to dial telephone or pager  
numbers according to the file named  
/etc/belkin/belkin.pgr  
This is also a plain text file, words in the first line denotes  
the pager port Belkin Power Management Software will  
use when power event occurs, line(s) between the first  
and the second lines with a '~' mark leading to denote the  
pager number(s) Belkin Power Management Software will  
dial when utility is fail, line(s) between the second and the  
third lines with a '~' mark leading to denote the pager  
number(s) Belkin Power Management Software will dial  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
when utility recover, line(s) between the third and the  
fourth lines with a '~' mark leading to denote the pager  
number(s) Belkin Power Management Software will dial  
when battery capacity is about to deplete , line(s) below  
the fourth line with a '~' mark leading to denote the pager  
number(s) Belkin Power Management Software will dial  
when battery capacity recover , so , the content of Belkin  
Power Management Software.pgr will looks like  
/dev/ttyS1  
~AC FAIL  
0957608176,,,,,#1331111#  
~AC RECOVER  
0957608176,,,,,#1332222#  
0931726768,,,,,#1332222#  
~BATTERY LOW  
0957608176,,,,,#1333333#  
~BATTERY LOW RECOVER  
0957608176,,,,,#1334444#  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.3.6. Shutdown Batch Job  
Belkin Power Management Software for Unix provides a  
batch job function. This function enables you to execute  
some processes before system shutdown. The filename  
is:  
/etc/belkin/preshut.bat  
This is a plain text file. Use any editor to add or modify  
commands in this file. Add comments by placing a leading  
'#' to the line.  
4.3.7. Shutdown Command File  
This file contains the command needed to shut down the  
system. The filename is:  
/etc/belkin/shutdown.ini  
This file contains only one line of command. Please refer  
to your system’s operation manual before making any  
modifications. Be sure the command could actually  
shut down your system.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.4. Using Belkin Power Management Software for Unix  
4.4.1. Using the "Belkin Power Management Software"  
program  
After a successful installation, Belkin Power Management  
Software for Unix will become a background process at  
system startup. It is not necessary to start the background  
process manually. Belkin Power Management Software  
for Unix automatically detects and applies the  
modifications made in the configuration menu.  
Use these commands to execute any of the six options provided  
in the software program.  
Start the Belkin Power Management Software for Unix  
daemon process:  
“/etc/belkin/belkin start”  
Stop the Belkin Power Management Software for Unix  
daemon process:  
/etc/belkin/belkin stop  
Configure the parameters:  
/etc/belkin/belkin config  
(see 4.5.3)  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Monitor the UPS status:  
/etc/belkin/belkin status  
(see 4.5.5)  
Send Commands Directly to the UPS  
/etc/belkin/belkin issuer  
(see 4.5.6)  
Read Online Documentation  
/etc/belkin/belkin help  
Help is just a few keystrokes away. Press the letters or numbers  
and follow the instructions at the bottom of the screen to reach a  
particular help topic.  
In case you forgot any  
of the commands, just  
type “belkin”. A short  
description of each  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
program option would appear on the screen.  
4.4.2. Uninstall Belkin Power Management Software for  
Unix  
Follow these steps to uninstall Belkin Power  
Management Software for Unix.  
1. Stop the Belkin Power Management Software for Unix  
daemon process.  
(type “/etc/belkin/belkin stop”).  
2. Remove the directory ‘/etc/belkin’.  
3. Remove the Belkin Power Management Software for Unix  
startup process from the system.  
If your Operating System is:  
A. Linux  
Remove or mark the whole line containing this string  
in the file ‘/etc/rc.d/rc.local’:  
/etc/belkin/belkin start  
B. FreeBSD  
Remove or mark the whole line containing this string  
in the file ‘/etc/rc’:  
/etc/belkin/belkin start  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.5. Monitor the UPS Status  
The Belkin Power Management Software Status screen  
provides a visual status-check of important operating data  
such as input/output voltage, current, battery capacity,  
power loading and much more. You could monitor your  
local UPS while simultaneously monitoring several  
network UPSs.  
To Monitor Your Local UPS  
1. Type “/etc/belkin/belkin status” to bring up the initial  
select screen. A short description and function key  
definitions appear at the bottom of the screen.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
2. Press <enter>. Belkin Power Management Software  
Status checks the configuration settings  
This screen appears if you configured Belkin Power  
Management Software to monitor the UPS from the local  
serial port. Function key descriptions are at the bottom right  
corner of the screen.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
This screen appears if you configured Belkin Power  
Management Software to monitor the UPS through a local  
SNMP Agent.  
Press [m] to know more information such as system  
contact, system name and system location.  
Press [b] to return to the first screen.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
To monitor a remote UPS  
1. Type “/etc/belkin/belkin status” to bring up the initial  
select screen.  
2. Press [r]. Fields where you could input the IP Address  
and Community Name appears.  
3. Press [I]. Key in the IP Address of the remote SNMP  
Adapter. Press [enter] when through.  
4. Press [c]. Key in an appropriate Community Name for  
the remote SNMP Adapter. Press [enter] when through.  
5. Press [enter]. A screen displaying the UPS status  
appears.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
Press [m] to see more information such as system contact,  
system name and system location.  
Press [b] to continue viewing the UPS status.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.6. Control your UPS  
Belkin Power Management Software for Unix gives you  
the ability to shut down, restart, initiate self-tests and  
issue other commands to your local UPS. Just type  
“/etc/belkin/belkin issuer” to bring up the screens shown  
below. The screen displayed would depend on the Belkin  
Power Management Software configuration.  
Belkin Power Management Software configured to  
monitor the UPS from the serial port  
Short Description of Each Option  
[s] 10 Seconds Test  
UPS performs a 10 seconds self-test then returns to  
utility.  
[b] Test until Battery Low  
UPS performs self-test until battery becomes low.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
[n] Shut Down UPS  
UPS stops providing output power after a few seconds.  
[a] Cancel Shut Down Command  
Cancel an impending UPS shutdown or turns on the  
UPS if utility is present.  
Belkin Power Management Software configured to  
monitor the UPS from an SNMP Agent  
Short Description of Each Option  
[s] Shut Down UPS  
UPS stops providing output power after a few seconds.  
[c] Cancel Shut Down Command  
Cancels an impending UPS shutdown.  
[o] Turn On UPS  
Turns on the UPS if utility is present.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
[u] Reboot UPS  
UPS shuts off then turns back on.  
[l] Put UPS to Sleep  
Specify the duration of sleep using [+] and [-] keys.  
UPS will not provide output power while in sleep mode.  
[m] Simulate Power Fail  
UPS switches to battery power.  
[b] Conserve Battery  
UPS on battery goes to sleep mode.  
[d] Diagnostic Self Test  
UPS performs a short diagnostic self-test.  
[t] Test Run Time Calibration  
The UPS discharges it’s batteries until capacity is less  
than 25%  
[f] Flash and Beep  
UPS lights all indicators and beeps.  
[I] Test Indicators  
UPS performs a front panel lights test.  
4.7. History Information  
Belkin Power Management Software for Unix records all  
power events in the file /etc/belkin/rupslog. You could  
review this information to check if there was any  
occurrence of power failure.  
Use any text editor to open the file "/etc/belkin/rupslog".  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.8. Files List and CD Contents  
Operating System  
Linux  
File Name  
Linux.tar.gz  
FreeBSD  
Freebsd.tar.gz  
4.9. Instruction to mount CD-ROM  
Operating  
command  
Parameters evice name  
directory  
System  
Linux  
FreeBSD  
mount  
mount  
-t iso9660  
-t cd9660  
/dev/hdd  
/mnt/cdrom  
/mnt/cdrom  
/dev/acd0c  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belkin Power Management Software  
4.10. System Parameters  
Shutdown  
Command  
Operating  
System  
COM Port  
Start up file  
Linux  
/dev/ttyS0  
/dev/ttyd0  
/sbin/halt  
/etc/rc.d/rc.local  
/etc/rc  
FreeBSD  
Shutdown -h now  
4.11. Belkin Power Management Software FAQ  
Q1 Belkin Power Management Software for Unix works fine  
when manually activated but an error message "UPS  
adapter no response!" appears when the system  
activates it at start-up.  
Answer:  
Make sure no other process uses the same serial port as  
Belkin Power Management Software for Unix daemon.  
Q2. I tried running the Belkin Power Management Software  
for Unix on FreeBSD Unix system, but it doesn't work,  
why?  
Answer:  
Belkin Power Management Software for Unix uses Unix  
IPC (Inter Process Communication) functions. FreeBSD  
does support System V IPC primitives, but you must  
install this option first. Add the following lines to your  
kernel config to enable Inter Process Communication.  
options SYSVSHM  
options "SHMMAXPGS=64"  
memory  
# 256Kb of sharable  
options SYSVSEM  
options SYSVMSG  
# enable for semaphores  
# enable for messaging  
Recompile and install.  
Please refer to FreeBSD WebSite for detailed  
information about these subjects.  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Switch F1DL102 User Manual
Blue Rhino Charcoal Grill CBC741W User Manual
Blue Rhino Patio Heater GWU9209W User Manual
Bosch Appliances Range HBL 73 User Manual
Braun Coffeemaker CafHouse Pure KF 550 User Manual
Brother Sewing Machine 885 V14 User Manual
Campbell Hausfeld Nail Gun CHN50399 User Manual
Canon All in One Printer 1827B001 User Manual
Canon Projector LV X4 LV 7230 User Manual
Char Broil Charcoal Grill 10301569 User Manual