Olympus Microscope Magnifier CKX41 User Manual

INVERTED MICROSCOPE  
CKX41/CKX31  
A new advance in routine inspections  
UNIVERSAL  
INFINITY SYSTEM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clear, wide-ranging phase-contrast observation.  
Ideal phase plate for cell culture.  
Clear cell observation right to the edge of the container.  
PHC objective virtually unaffected by surface tension.  
Low magnification UIS video adapters can be used for  
0.25X, 0.35X and 0.5X magnifications, enabling clear  
display of the complete cell on the monitor.  
Clear up to the edge of the view field.  
Flatness improved for 10 to 15%  
Standard field number 20  
Maximum field number 22  
The UIS optics provide unsurpassed optical performance  
PHC objective minimally affected by  
The UIS optical system combines with the simplicity of the light path  
and the imaging excellence of a relay lenses to maintain the highest  
possible image intensity and to arrive at the highest optical  
correction level. Thanks to this feature, the UIS infinity-corrected  
optical system deliver unsurpassed resolution and contrast.  
In addition to improved image quality, the maximum field of view  
has been extended to F.N. 22. This allows the use of various  
observation tubes provided for upright microscopes (patented,  
CKX41 only).  
surface tension around the container edge  
The PHC objective is minimally affected by surface tension of the  
culture fluid, which can compromise clarity at the image periphery.  
Easier multi-well observation is one of several benefits. Combined  
with the improved flatness  
resulting from the use  
of UIS optics, this  
feature facilitates  
clear observation of  
cells even at the  
edge of the container.  
Enhanced clarity makes it easier to  
observe cell activity status  
PHC objective  
UIS infinity-corrected optical system  
The advanced Olympus UIS optical system maximized the advantages of infinity  
correction. Light travels through the body tube as parallel rays as it passes through  
the objective. These are focused by the tube lens to form a completely aberration-  
free intermediate image. Attachments can be added between the objective and the  
built-in tube lens in the observation tube without any magnification factor alterations  
to total magnification. Additional correction lenses are not required The UIS optical  
system delivers optimum image quality with any configuration.  
General objective  
Incorporation of the world-renowned Olympus UIS optical system  
in the CKX series makes a dramatic improvement in flatness for  
10 to 15% and enables very clear, high contrast images to be  
obtained up to the edge of the field view.  
Adoption of a UIS phase plate optimized for  
Half mirror  
Parallel light  
Image forming ray  
Primary focus plane  
cell culture observation provides higher image contrast  
The UIS phase plate adjusts the contrast according to the thickness  
of the cell culture, producing higher contrast images than those  
obtainable from conventional systems.  
Reflected ray  
Tube lens  
Objective  
Illumination light  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Just set the specimen on the stage and observe  
immediately while standing, with no optical adjustments.  
Pre-centered phase-contrast slider for quick,  
adjustment-free observation  
Tilting binocular tube for observation while standing  
The binocular tube has a 30-60 degree tilting mechanism to let the  
researcher make observations while standing. The specimen is  
removed from the incubator and placed straight onto the  
microscope stage, so that cell checking can be done immediately.  
"Quick observation, quick return"— that’s the new style of routine  
inspection made possible by Olympus.  
With the pre-centered phase-contrast slider, there is no need to  
repeat centering each time the objective magnification is changed.  
Likewise, ring slit exchange when swapping between objectives is  
also unnecessary, since the ring slit is standardized for 10X, 20X  
and 40X magnifications. The CKX series makes phase-contrast  
observations quick and easy, without optical adjustments, for much  
more efficient performance of routine tasks. Since the phase plate  
transmission rates are dictated by the objective in use, the  
brightness remains constant  
even when the magnification  
is changed.  
*The IX2-SL with centering mechanism  
enables maximized phase-contrast  
performance with precise optical  
adjustments.  
10X  
20X  
40X  
Easy observation at the clean bench  
The tilting binocular tube combination makes it unnecessary for  
researchers to adopt uncomfortable postures like lowering their face  
to the inside of the clean bench. Simply observe down the tube  
while working, and raise the tube afterwards: this method is much  
more convenient, since the clean bench can be opened/closed  
without moving the microscope.  
4X  
10X, 20X, 40X  
Empty slot  
Slim, compact design takes up minimum laboratory space  
The slim, compact design minimizes the depth of the microscope,  
allowing easy installation right beside the incubator or clean bench.  
Specimens can be taken and immediately set on the microscope  
stage for quick, efficient inspection.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Relief contrast observations  
High-resolution relief contrast with N.A.0.5:  
thick specimens like egg cells can be  
observed in three dimensions  
Olympus' relief contrast maintains the same shadow  
direction even if the magnification is changed.  
The two-stage exchange slider uses a common  
aperture for 20X and 40X magnifications, so exchange  
between 10X/20X and 10X/40X is performed quickly.  
The same feature enables easy optical adjustment:  
by simply using the lever, the contrast can be  
changed while centering is being performed.  
Vertical installation avoids interference with  
manipulators  
Vertical installation helps the user to avoid accidentally  
touching the manipulators while operating the slider or  
making optical adjustments.  
Fluorescence observations  
Fluorescence observation system with  
tree-position allows the use of U excitation.  
Adopted renowned UIS optics, this system provides  
B and G excitations and optionally U excitation as well.  
All three can be provided simultaneously, with quick,  
easy exchange among them. Many different UIS filters  
can also be installed, according to requirements,  
enabling this system to meet a wide range of  
fluorescence observations needs.  
Also, thanks to newly developed fluorescent illuminator,  
which secured UV transmission rate, and a variety of  
UIS fluorescent  
objectives, clear  
and high contrast  
fluorescent  
images are  
provided.  
Accessories  
Suitable for blood cell plates and  
other kinds of micro-plate  
The mechanical stage offers  
excellent inspection performance  
with blood cell plates or other micro-  
plates.  
Glass stage insert plate and  
warm plate  
Cost-effective digital imaging  
Mounting the trinocular tube on the CKX41 makes it  
possible to attach the DP12  
digital camera or  
different types of  
video cameras.  
Also included are a glass stage  
insert plate, for simple confirmation  
of the objective in use, and a warm  
plate for easy temperature control  
(CKX41 only).  
CKX41+DP12  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CKX41/CKX31 specifications  
Objective lens specifications  
Item  
CKX41  
CKX31  
Objective  
PLC4X  
N.A. W.D.(mm) Remarks  
Optical system  
Focus  
UIS (Universal Infinity-corrected) optical system  
Vertical nosepiece movement (stage is fixed),  
coaxial coarse and fine focus with tension adjustment mechanism, roller slide mechanism,  
stroke: 7mm up and 2mm down from focus position which is 1mm above the stage,  
stroke per rotation: 39.6mm (coarse), 0.2mm (fine)  
0.10  
0.25  
0.40  
0.60  
0.13  
0.25  
0.25  
22.0  
10.5  
3.0  
2.6  
17.0  
9.8  
10.5  
3.2  
6.9  
2.2  
2.6  
17.0  
8.8  
3.2  
2.2  
9.5  
2.8  
1.9  
17  
PLC10X  
ACH20X  
LCPLFL40X  
UPLFL4XPH  
CPL10XPH  
PL10XPH  
PHL (for use with IX2-SL)  
PHC (for use with IX2-SL)  
PH1 (for use with IX2-SL)  
PHC (for use with IX2-SL)  
PH1 (for use with IX2-SL)  
PH2 (for use with IX2-SL)  
PH2 (for use with IX2-SL)  
For use with IX2-SLP  
For use with IX2-SLP  
For use with IX2-SLP  
For use with IX2-SLP  
For use with CKX-RC  
For use with CKX-RC  
For use with CKX-RC  
U,B,G  
Revolving nosepiece  
Quadruple  
Stage  
Plain stage  
160mm(L) x 250mm(W), stage clips attachable  
Exchangeable insert plate (ø25mm opening) incorporated  
ø35 petri dish holder stage  
incorporated  
LCACH20XPH 0.40  
LCPLFL20XPH 0.40  
LCACH40X2PH 0.55  
Mechanical stage  
Substage  
Right-hand low drive coaxial controls,  
stage movement: X=120mm, Y=78mm, with three dish/sample holders  
70(L) X180(W)mm  
LCPLFL40XPH  
0.6  
Illumination Light source  
system  
6V,30W halogen lamp, lamp socket (U-LS30-3-2),  
built-in frosted and heat absorbing filters, detachable illuminator  
UPLFL4XPHP* 0.13  
CACH10XPHP* 0.25  
LCACH20XPHP* 0.40  
LCACH40XPHP* 0.55  
Filter holder  
Insert up to 11mm thick with ø45mm filter, detachable  
Aperture diaphragm Lever type, range: from minimum ø3mm to maximum ø44mm  
Slider insertion With phase slider pocket and built-in slider position click stop mechanism  
CPL10XRC  
0.25  
0.4  
Condenser  
Detachable ultra-long working distance condenser (N.A. 0.3, W.D. 72mm)  
LCACH20XRC  
Contrast slider  
Pre-centered phase-contrast: 4X, 10X/20X/40X, empty slot  
Centerable phase-contrast: 4X, 10X/20X, empty slot (40X optional, pre-centered)  
Centerable for Relief Contrast: 10X, 20X, 40X  
U-CBI30-2: inclined 30°, interpupillary distance range: 48-75mm,  
diopter adjustment by helicoid on left sleeve (F.N. 20)  
LCACH40XRC 0.55  
UPLFL4X  
0.13  
0.3  
0.5  
0.4  
Observation Binocular tube  
tube  
Fixed binocular tube, inclined  
UPLFL10X  
UPLFL20X  
LCPLFL20X  
LUCPLFL40X  
10  
U,B,G  
45°, interpupillary distance range:  
48-75mm, diopter adjustment by  
helicoid on right sleeve  
1.6  
6.9  
U,B,G  
U-BI30-2: inclined 30°, interpupillary distance range: 48-75mm,  
diopter adjustment by helicoid on left sleeve (F.N. 22)  
B,G  
Trinocular tube  
U-CTR30-2: inclined 30°, ring dovetail attachment,  
interpupillary distance range: 48-75mm, tube length  
and diopter adjustment by helicoid on left sleeve  
0.6 2.7 - 4.0  
* Pre-centering objective  
Observation optical path: 50(binocular)/50(video port) (F.N. 20)  
U-TR30-2: inclined 30°, ring dovetail attachment,  
interpupillary distance range: 48-75mm, tube length  
and diopter adjustment by helicoid on left sleeve  
Observation optical path: 50(binocular)/50(video port) (F.N. 22)  
Tilting binocular  
tube  
CKX-TBI: variable inclination angles from 30° to 60°,  
interpupillary distance range: 50-76mm,  
diopter adjustment by helicoid on right sleeve (F.N. 20)  
UTBI-3: variable inclination angles from 5° to 35°, circular  
mounting dovetail attachment, interpupillary distance range:  
50-76mm, diopter adjustment by helicoid on right sleeve. (F.N. 22)  
Fluorescent illuminator  
Detachable illuminator,  
switchable slide (3-position: B excitation, G excitation, empty slot or U excitation)  
FL light source  
FL light shutter  
FL field stop  
FL cubes  
50W Hg  
Available  
Available  
2 cubes (B & G), option U  
(cubes are not compartible with UIS. Filter and dichroic mirror size are same as UIS)  
1 filter  
Filter  
Eyepiece  
For U-CBI30-2/U-CTR30-2/CKX-TBI: WHB10X/WHB10X-H (F.N. 20) 10X (F.N.: 20)  
For U-BI30-2/U-TR30-2/U/TBI3: WH10X/WH10X-H/35WH10X/  
PWH10X (F.N. 22)  
Power supply  
Continuous intensity adjustment,  
built-in voltage changeover switch (100/120V, 220/240V), frequency 50/60Hz  
CKX41/CKX31 dimensions  
(unit: mm)  
364  
370.5  
486.6  
364  
370.5  
515.5  
237.6  
237.6  
ISO9001  
ISO14001  
Certification  
Certification  
Design and production at the Olympus  
Optical Co. Ltd. Ina Plant conforms with  
ISO14001 specifications for  
Design and production  
Accredited by the  
Dutch Council for  
Accreditation  
adheres to ISO9001  
ISO 9001  
internationalquality standard.  
environmental management systems.  
Specifications are subject to change without any obligation on the part of the manufacturer.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milwaukee Battery Charger 48 59 0255 User Manual
MTD Snow Blower E614E User Manual
NEC Flat Panel Television M40 2 AVT User Manual
New Buck Corporation Stove GAS STOVE HEATER User Manual
NordicTrack Treadmill NTL118061 User Manual
Nortel Networks Telephone ICS 41 User Manual
Nostalgia Electrics Fondue Maker LPF 210 User Manual
Packard Bell Personal Computer REFDOCS02420200 User Manual
Panasonic Camcorder AJ D615MC User Manual
Parkside Sander XQ600 User Manual