INVERTED MICROSCOPE
CKX41/CKX31
A new advance in routine inspections
UNIVERSAL
INFINITY SYSTEM
Download from Www.Somanuals.com. All Manuals Search And Download.
Clear, wide-ranging phase-contrast observation.
Ideal phase plate for cell culture.
Clear cell observation right to the edge of the container.
PHC objective virtually unaffected by surface tension.
Low magnification UIS video adapters can be used for
0.25X, 0.35X and 0.5X magnifications, enabling clear
display of the complete cell on the monitor.
Clear up to the edge of the view field.
Flatness improved for 10 to 15%
Standard field number 20
Maximum field number 22
The UIS optics provide unsurpassed optical performance
PHC objective minimally affected by
The UIS optical system combines with the simplicity of the light path
and the imaging excellence of a relay lenses to maintain the highest
possible image intensity and to arrive at the highest optical
correction level. Thanks to this feature, the UIS infinity-corrected
optical system deliver unsurpassed resolution and contrast.
In addition to improved image quality, the maximum field of view
has been extended to F.N. 22. This allows the use of various
observation tubes provided for upright microscopes (patented,
CKX41 only).
surface tension around the container edge
The PHC objective is minimally affected by surface tension of the
culture fluid, which can compromise clarity at the image periphery.
Easier multi-well observation is one of several benefits. Combined
with the improved flatness
resulting from the use
of UIS optics, this
feature facilitates
clear observation of
cells even at the
edge of the container.
Enhanced clarity makes it easier to
observe cell activity status
PHC objective
UIS infinity-corrected optical system
The advanced Olympus UIS optical system maximized the advantages of infinity
correction. Light travels through the body tube as parallel rays as it passes through
the objective. These are focused by the tube lens to form a completely aberration-
free intermediate image. Attachments can be added between the objective and the
built-in tube lens in the observation tube without any magnification factor alterations
to total magnification. Additional correction lenses are not required The UIS optical
system delivers optimum image quality with any configuration.
General objective
Incorporation of the world-renowned Olympus UIS optical system
in the CKX series makes a dramatic improvement in flatness for
10 to 15% and enables very clear, high contrast images to be
obtained up to the edge of the field view.
Adoption of a UIS phase plate optimized for
Half mirror
Parallel light
Image forming ray
Primary focus plane
cell culture observation provides higher image contrast
The UIS phase plate adjusts the contrast according to the thickness
of the cell culture, producing higher contrast images than those
obtainable from conventional systems.
Reflected ray
Tube lens
Objective
Illumination light
2
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Just set the specimen on the stage and observe
immediately while standing, with no optical adjustments.
Pre-centered phase-contrast slider for quick,
adjustment-free observation
Tilting binocular tube for observation while standing
The binocular tube has a 30-60 degree tilting mechanism to let the
researcher make observations while standing. The specimen is
removed from the incubator and placed straight onto the
microscope stage, so that cell checking can be done immediately.
"Quick observation, quick return"— that’s the new style of routine
inspection made possible by Olympus.
With the pre-centered phase-contrast slider, there is no need to
repeat centering each time the objective magnification is changed.
Likewise, ring slit exchange when swapping between objectives is
also unnecessary, since the ring slit is standardized for 10X, 20X
and 40X magnifications. The CKX series makes phase-contrast
observations quick and easy, without optical adjustments, for much
more efficient performance of routine tasks. Since the phase plate
transmission rates are dictated by the objective in use, the
brightness remains constant
even when the magnification
is changed.
*The IX2-SL with centering mechanism
enables maximized phase-contrast
performance with precise optical
adjustments.
10X
20X
40X
Easy observation at the clean bench
The tilting binocular tube combination makes it unnecessary for
researchers to adopt uncomfortable postures like lowering their face
to the inside of the clean bench. Simply observe down the tube
while working, and raise the tube afterwards: this method is much
more convenient, since the clean bench can be opened/closed
without moving the microscope.
4X
10X, 20X, 40X
Empty slot
Slim, compact design takes up minimum laboratory space
The slim, compact design minimizes the depth of the microscope,
allowing easy installation right beside the incubator or clean bench.
Specimens can be taken and immediately set on the microscope
stage for quick, efficient inspection.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Relief contrast observations
High-resolution relief contrast with N.A.0.5:
thick specimens like egg cells can be
observed in three dimensions
Olympus' relief contrast maintains the same shadow
direction even if the magnification is changed.
The two-stage exchange slider uses a common
aperture for 20X and 40X magnifications, so exchange
between 10X/20X and 10X/40X is performed quickly.
The same feature enables easy optical adjustment:
by simply using the lever, the contrast can be
changed while centering is being performed.
Vertical installation avoids interference with
manipulators
Vertical installation helps the user to avoid accidentally
touching the manipulators while operating the slider or
making optical adjustments.
Fluorescence observations
Fluorescence observation system with
tree-position allows the use of U excitation.
Adopted renowned UIS optics, this system provides
B and G excitations and optionally U excitation as well.
All three can be provided simultaneously, with quick,
easy exchange among them. Many different UIS filters
can also be installed, according to requirements,
enabling this system to meet a wide range of
fluorescence observations needs.
Also, thanks to newly developed fluorescent illuminator,
which secured UV transmission rate, and a variety of
UIS fluorescent
objectives, clear
and high contrast
fluorescent
images are
provided.
Accessories
Suitable for blood cell plates and
other kinds of micro-plate
The mechanical stage offers
excellent inspection performance
with blood cell plates or other micro-
plates.
Glass stage insert plate and
warm plate
Cost-effective digital imaging
Mounting the trinocular tube on the CKX41 makes it
possible to attach the DP12
digital camera or
different types of
video cameras.
Also included are a glass stage
insert plate, for simple confirmation
of the objective in use, and a warm
plate for easy temperature control
(CKX41 only).
CKX41+DP12
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CKX41/CKX31 specifications
Objective lens specifications
Item
CKX41
CKX31
Objective
PLC4X
N.A. W.D.(mm) Remarks
Optical system
Focus
UIS (Universal Infinity-corrected) optical system
Vertical nosepiece movement (stage is fixed),
coaxial coarse and fine focus with tension adjustment mechanism, roller slide mechanism,
stroke: 7mm up and 2mm down from focus position which is 1mm above the stage,
stroke per rotation: 39.6mm (coarse), 0.2mm (fine)
0.10
0.25
0.40
0.60
0.13
0.25
0.25
22.0
10.5
3.0
2.6
17.0
9.8
10.5
3.2
6.9
2.2
2.6
17.0
8.8
3.2
2.2
9.5
2.8
1.9
17
PLC10X
ACH20X
LCPLFL40X
UPLFL4XPH
CPL10XPH
PL10XPH
PHL (for use with IX2-SL)
PHC (for use with IX2-SL)
PH1 (for use with IX2-SL)
PHC (for use with IX2-SL)
PH1 (for use with IX2-SL)
PH2 (for use with IX2-SL)
PH2 (for use with IX2-SL)
For use with IX2-SLP
For use with IX2-SLP
For use with IX2-SLP
For use with IX2-SLP
For use with CKX-RC
For use with CKX-RC
For use with CKX-RC
U,B,G
Revolving nosepiece
Quadruple
Stage
Plain stage
160mm(L) x 250mm(W), stage clips attachable
Exchangeable insert plate (ø25mm opening) incorporated
ø35 petri dish holder stage
incorporated
LCACH20XPH 0.40
LCPLFL20XPH 0.40
LCACH40X2PH 0.55
Mechanical stage
Substage
Right-hand low drive coaxial controls,
stage movement: X=120mm, Y=78mm, with three dish/sample holders
70(L) X180(W)mm
LCPLFL40XPH
0.6
Illumination Light source
system
6V,30W halogen lamp, lamp socket (U-LS30-3-2),
built-in frosted and heat absorbing filters, detachable illuminator
UPLFL4XPHP* 0.13
CACH10XPHP* 0.25
LCACH20XPHP* 0.40
LCACH40XPHP* 0.55
Filter holder
Insert up to 11mm thick with ø45mm filter, detachable
Aperture diaphragm Lever type, range: from minimum ø3mm to maximum ø44mm
Slider insertion With phase slider pocket and built-in slider position click stop mechanism
CPL10XRC
0.25
0.4
Condenser
Detachable ultra-long working distance condenser (N.A. 0.3, W.D. 72mm)
LCACH20XRC
Contrast slider
•Pre-centered phase-contrast: 4X, 10X/20X/40X, empty slot
•Centerable phase-contrast: 4X, 10X/20X, empty slot (40X optional, pre-centered)
•Centerable for Relief Contrast: 10X, 20X, 40X
U-CBI30-2: inclined 30°, interpupillary distance range: 48-75mm,
diopter adjustment by helicoid on left sleeve (F.N. 20)
LCACH40XRC 0.55
UPLFL4X
0.13
0.3
0.5
0.4
Observation Binocular tube
tube
Fixed binocular tube, inclined
UPLFL10X
UPLFL20X
LCPLFL20X
LUCPLFL40X
10
U,B,G
45°, interpupillary distance range:
48-75mm, diopter adjustment by
helicoid on right sleeve
1.6
6.9
U,B,G
U-BI30-2: inclined 30°, interpupillary distance range: 48-75mm,
diopter adjustment by helicoid on left sleeve (F.N. 22)
B,G
Trinocular tube
U-CTR30-2: inclined 30°, ring dovetail attachment,
interpupillary distance range: 48-75mm, tube length
and diopter adjustment by helicoid on left sleeve
0.6 2.7 - 4.0
* Pre-centering objective
Observation optical path: 50(binocular)/50(video port) (F.N. 20)
U-TR30-2: inclined 30°, ring dovetail attachment,
interpupillary distance range: 48-75mm, tube length
and diopter adjustment by helicoid on left sleeve
Observation optical path: 50(binocular)/50(video port) (F.N. 22)
—
Tilting binocular
tube
CKX-TBI: variable inclination angles from 30° to 60°,
interpupillary distance range: 50-76mm,
diopter adjustment by helicoid on right sleeve (F.N. 20)
UTBI-3: variable inclination angles from 5° to 35°, circular
mounting dovetail attachment, interpupillary distance range:
50-76mm, diopter adjustment by helicoid on right sleeve. (F.N. 22)
Fluorescent illuminator
Detachable illuminator,
switchable slide (3-position: B excitation, G excitation, empty slot or U excitation)
FL light source
FL light shutter
FL field stop
FL cubes
50W Hg
Available
Available
2 cubes (B & G), option U
(cubes are not compartible with UIS. Filter and dichroic mirror size are same as UIS)
1 filter
Filter
Eyepiece
For U-CBI30-2/U-CTR30-2/CKX-TBI: WHB10X/WHB10X-H (F.N. 20) 10X (F.N.: 20)
For U-BI30-2/U-TR30-2/U/TBI3: WH10X/WH10X-H/35WH10X/
PWH10X (F.N. 22)
Power supply
Continuous intensity adjustment,
built-in voltage changeover switch (100/120V, 220/240V), frequency 50/60Hz
CKX41/CKX31 dimensions
(unit: mm)
364
370.5
486.6
364
370.5
515.5
237.6
237.6
ISO9001
ISO14001
Certification
Certification
Design and production at the Olympus
Optical Co. Ltd. Ina Plant conforms with
ISO14001 specifications for
Design and production
Accredited by the
Dutch Council for
Accreditation
adheres to ISO9001
ISO 9001
internationalquality standard.
environmental management systems.
Specifications are subject to change without any obligation on the part of the manufacturer.
Download from Www.Somanuals.com. All Manuals Search And Download.
|