Craftsman Air Compressor 919728000 User Manual

CRAFTSMAN  
OWNERS MANUAL FOR  
CRAFTSMAN  
TANK MOUNTED  
AIR COMPRESSOR  
Model No.  
919.728000  
Record in the spaces provided.  
(1) The Model Number can be found on the  
maintenance label on top of the motor  
shroud or on the bar code label on the  
rear of air tank.  
(2) The Date Code Number can be found on  
the bar code label on the rear of the air  
tank.  
(3) The Serial Number can be found on the  
bar code label on the rear of the tank.  
(4) The Tank Registration Number is located  
on the metal data plate which is welded  
onto the backside of the air tank. (This  
data plate is painted the same color as the  
tank.)  
Retain these numbers for future reference.  
Model No________________________  
SAFETY GUIDELINES  
ASSEMBLY  
OPERATION  
MAINTENANCE  
TROUBLESHOOTING  
REPAIR PARTS  
IMPORTANT:  
Read the Safety Guidelines  
and All Instructions Carefully  
Before Operating  
Serial No________________________  
Date Code_______________________  
Tank Registration No______________  
Sold by Sears Canada, Inc., Toronto, Ont. M5B 2B8  
D21245 Rev. 4 7/18/01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
SAVE THESE INSTRUCTIONS  
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY  
DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.  
HAZARD  
RISK OF EXPLOSION OR FIRE  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE  
MOTOR AND PRESSURE SWITCH TO SPARK.  
ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTI-  
LATED AREA FREE OF COMBUSTIBLE MATERIALS,  
GASOLINE OR SOLVENT VAPORS.  
IF SPRAYING FLAMMABLE MATERIALS, LOCATE COMPRES-  
SOR AT LEAST 20 FEET AWAY FROM SPRAY AREA. AN  
ADDITIONAL LENGTH OF HOSE MAY BE REQUIRED.  
IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO  
CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE,  
CAUSING FIRE OR EXPLOSION.  
STORE FLAMMABLE MATERIALS IN A SECURE LOCATION  
AWAY FROM COMPRESSOR.  
RESTRICTING ANY OF THE COMPRESSOR VENTILATION  
OPENINGS WILL CAUSE SERIOUS OVERHEATING AND  
COULD CAUSE FIRE.  
NEVER PLACE OBJECTS AGAINST OR ON TOP OF COM-  
PRESSOR. OPERATE COMPRESSOR IN AN OPEN AREA AT  
LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUC-  
TION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO  
THE VENTILATION OPENINGS.  
OPERATE COMPRESSOR IN A CLEAN, DRY, WELL VENTI-  
LATED AREA. DO NOT OPERATE UNIT INDOORS OR IN ANY  
CONFINED AREA.  
UNATTENDED OPERATION OF THIS PRODUCT COULD  
RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE.  
ALWAYS REMAIN IN ATTENDANCE WITH THE PRODUCT  
WHEN IT IS OPERATING.  
RISK OF BURSTING  
AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A  
VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY.  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
1. FAILURE TO PROPERLY DRAIN CONDENSED WATER  
FROM THE TANK, CAUSING RUST AND THINNING OF THE  
STEEL TANK.  
DRAIN TANK DAILY OR AFTER EACH USE. IF TANK DEVEL-  
OPS A LEAK, REPLACE IT IMMEDIATELY WITH A NEW TANK OR  
REPLACE THE ENTIRE COMPRESSOR.  
NEVER DRILL INTO, WELD, OR MAKE ANY MODIFICATIONS  
TO THE TANK OR ITS ATTACHMENTS.  
2. MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK.  
THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING  
PRESSURES. NEVER MAKE ADJUSTMENTS OR PARTS  
SUBSTITUTIONS TO ALTER THE FACTORY SET OPERATING  
PRESSURES.  
3. UNAUTHORIZED MODIFICATIONS TO THE UNLOADER  
VALVE, SAFETY VALVE, OR ANY OTHER COMPONENTS  
WHICH CONTROL TANK PRESSURE.  
4. EXCESSIVE VIBRATION CAN WEAKEN THE AIR TANK  
AND CAUSE RUPTURE OR EXPLOSION.  
ATTACHMENTS & ACCESSORIES:  
FOR ESSENTIAL CONTROL OF AIR PRESSURE, YOU MUST  
INSTALL A PRESSURE REGULATOR AND PRESSURE GAUGE  
TO THE AIR OUTLET OF YOUR COMPRESSOR. FOLLOW THE  
EQUIPMENT MANUFACTURERS RECOMMENDATION AND  
NEVER EXCEED THE MAXIMUM ALLOWABLE PRESSURE  
RATING OF ATTACHMENTS. NEVER USE COMPRESSOR TO  
INFLATE SMALL LOW-PRESSURE OBJECTS SUCH AS  
CHILDREN’S TOYS, FOOTBALLS, BASKETBALLS. ETC.  
EXCEEDING THE PRESSURE RATING OF AIR TOOLS, SPRAY  
GUNS, AIR OPERATED ACCESSORIES, TIRES AND OTHER  
INFLATABLES CAN CAUSE THEM TO EXPLODE OR FLY  
APART, AND COULD RESULT IN SERIOUS INJURY.  
D21245  
3 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HAZARD  
RISK FROM FLYING OBJECTS  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE  
DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT, CHIPS,  
LOOSE PARTICLES AND SMALL OBJECTS AT HIGH SPEED,  
RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY.  
ALWAYS WEAR ANSI Z87.1 APPROVED SAFETY GLASSES  
WITH SIDE SHIELDS WHEN USING THE COMPRESSOR.  
NEVER POINT ANY NOZZLE OR SPRAYER TOWARD ANY  
PART OF THE BODY OR AT OTHER PEOPLE OR ANIMALS.  
ALWAYS TURN THE COMPRESSOR OFF AND BLEED PRES-  
SURE FROM THE AIR HOSE AND TANK BEFORE ATTEMPTING  
MAINTENANCE, ATTACHING TOOLS OR ACCESSORIES.  
RISK TO BREATHING  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
THE COMPRESSED AIR FROM YOUR COMPRESSOR IS NOT  
SAFE FOR BREATHING! THE AIR STREAM MAY CONTAIN  
CARBON MONOXIDE, TOXIC VAPORS OR SOLID PARTICLES  
FROM THE TANK.  
ALWAYS OPERATE AIR COMPRESSOR OUTSIDE IN A CLEAN,  
WELL VENTILATED AREA. AVOID ENCLOSED AREAS SUCH AS  
GARAGES, BASEMENTS, STORAGE SHEDS, WHICH LACK A  
STEADY EXCHANGE OF AIR. KEEP CHILDREN, PETS AND  
OTHERS AWAY FROM AREA OF OPERATION.  
NEVER INHALE AIR FROM THE COMPRESSOR EITHER  
DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO  
THE COMPRESSOR.  
WORK IN AN AREA WITH GOOD CROSS-VENTILATION. READ  
AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON  
THE LABEL OR SAFETY DATA SHEETS FOR THE MATERIAL  
YOU ARE SPRAYING. USE A NIOSH/MSHA APPROVED  
RESPIRATOR DESIGNED FOR USE WITH YOUR SPECIFIC  
APPLICATION.  
SPRAYED MATERIALS SUCH AS PAINT, PAINT SOLVENTS,  
PAINT REMOVER, INSECTICIDES, WEED KILLERS, CONTAIN  
HARMFUL VAPORS AND POISONS.  
RISK OF ELECTRICAL SHOCK  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
YOUR AIR COMPRESSOR IS POWERED BY ELECTRICITY.  
LIKE ANY OTHER ELECTRICALLY POWERED DEVICE, IF IT IS  
NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK.  
NEVER OPERATE THE COMPRESSOR OUTDOORS WHEN IT IS  
RAINING OR IN WET CONDITIONS.  
NEVER OPERATE COMPRESSOR WITH COVER COMPONENTS  
REMOVED OR DAMAGED.  
ANY ELECTRICAL WIRING OR REPAIRS REQUIRED ON THIS  
PRODUCT SHOULD BE PERFORMED BY AUTHORIZED  
SERVICE CENTER PERSONNEL IN ACCORDANCE WITH  
NATIONAL AND LOCAL ELECTRICAL CODES.  
REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN  
RESULT IN SERIOUS INJURY OR DEATH BY ELECTROCU-  
TION.  
MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH  
THE COMPRESSOR IS CONNECTED PROVIDES PROPER  
ELECTRICAL GROUNDING, CORRECT VOLTAGE AND  
ADEQUATE FUSE PROTECTION.  
ELECTRICAL GROUNDING: FAILURE TO PROVIDE ADEQUATE  
GROUNDING TO THIS PRODUCT COULD RESULT IN SERIOUS  
INJURY OR DEATH FROM ELECTROCUTION. SEE GROUND-  
ING INSTRUCTIONS.  
D21245  
4 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HAZARD  
RISK FROM MOVING PARTS  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELT  
CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT  
WITH YOU OR YOUR CLOTHING.  
NEVER OPERATE THE COMPRESSOR WITH GUARDS OR  
COVERS WHICH ARE DAMAGED OR REMOVED.  
ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED  
OR MISSING PARTS OR ATTEMPTING TO REPAIR COM-  
PRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN  
EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN  
SERIOUS INJURY.  
ANY REPAIRS REQUIRED ON THIS PRODUCT SHOULD BE  
PERFORMED BY AUTHORIZED SERVICE CENTER PERSON-  
NEL.  
RISK OF BURNS  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
TOUCHING EXPOSED METAL SUCH AS THE COMPRESSOR  
HEAD OR OUTLET TUBES, CAN RESULT IN SERIOUS BURNS.  
NEVER TOUCH ANY EXPOSED METAL PARTS ON COMPRES-  
SOR DURING OR IMMEDIATELY AFTER OPERATION. COM-  
PRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER  
OPERATION.  
DO NOT REACH AROUND PROTECTIVE SHROUDS OR ATTEMPT  
MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL.  
RISK OF FALLING  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
A PORTABLE COMPRESSOR CAN FALL FROM A TABLE,  
WORKBENCH OR ROOF CAUSING DAMAGE TO THE COM-  
PRESSOR AND COULD RESULT IN SERIOUS INJURY OR  
DEATH TO THE OPERATOR.  
ALWAYS OPERATE COMPRESSOR IN A STABLE SECURE  
POSITION TO PREVENT ACCIDENTAL MOVEMENT OF THE  
UNIT. NEVER OPERATE COMPRESSOR ON A ROOF OR  
OTHER ELEVATED POSITION. USE ADDITIONAL AIR HOSE  
TO REACH HIGH LOCATIONS.  
RISK OF PROPERTY DAMAGE WHEN TRANSPORTING  
COMPRESSOR  
(Fire, Inhalation, Damage to Vehicle Surfaces)  
WHAT CAN HAPPEN  
HOW TO PREVENT IT  
OIL CAN LEAK OR SPILL AND COULD RESULT IN FIRE OR  
BREATHING HAZARD, SERIOUS INJURY OR DEATH CAN  
RESULT. OIL LEAKS WILL DAMAGE CARPET, PAINT OR OTHER  
SURFACES IN VEHICLES OR TRAILERS.  
ALWAYS PLACE COMPRESSOR ON A PROTECTIVE MAT WHEN  
TRANSPORTING TO PROTECT AGAINST DAMAGE TO VEHICLE  
FROM LEAKS. REMOVE COMPRESSOR FROM VEHICLE  
IMMEDIATELY UPON ARRIVAL AT YOUR DESTINATION.  
ESW-99 — 9/26/99  
D21245  
5 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL INFORMATION  
You have purchased an air compressor unit consisting  
An air line filter is usually required for removal of  
moisture and oil vapor in compressed air when a paint  
spray gun is used.  
of an aluminum 2 cylinder, single-stage air compressor  
pump (with cast iron sleeves), an air tank, wheels,  
handle, associated controls and instruments.  
An in-line lubricator is usually required for air tools to  
prolong tool life.  
Your air compressor can be used for operating paint  
spray guns, air tools, caulking guns, grease guns, air  
brushes, sandblasters, inflating tires and plastic toys,  
spraying weed killers, insecticides, etc. An air pres-  
sure regulator is required for most of these applica-  
tions.  
Separate air transformers which combine the functions  
of air regulation and/or moisture and dirt removal  
should be used where applicable.  
GLOSSARY  
CFM: Cubic Feet per Minute.  
Cut-Out Pressure: When you turn on your air com-  
pressor and it begins to run, air pressure in the air tank  
begins to build. It builds to a certain high pressure  
before the motor automatically shuts off - protecting  
your air tank from pressure higher than its capacity.  
The high pressure at which the motor shuts off is  
called “cut-out pressure.”  
SCFM: Standard Cubic Feet per Minute; a unit of  
measure of air delivery.  
PSI: Pounds per Square Inch; a unit of measure of  
pressure.  
ASME: American Society of Mechanical Engineers;  
made, tested, inspected and registered to meet the  
standards of the ASME.  
CSA: Electrical products sold in Canada are required  
to be certified to the applicable CSA standard (s).  
Canadian Standards Association (CSA) is a standards  
writing and safety testing organization. Products that  
are CSA certified have been evaluated and tested and  
found to meet or exceed the applicable CSA standard  
(s) for safety and electrical performance.  
Cut-In Pressure: While the motor is off, air tank  
pressure drops as you continue to use your accessory.  
When the tank pressure drops to a certain low level  
and the pressure switch lever is in "Auto", the motor  
will restart automatically. The low pressure at which  
the motor automatically restarts is called “cut-in  
pressure.”  
SPECIFICATION CHART  
Model No.  
919.728000  
2 3/8"  
1.35"  
120/240  
15 amps  
Bore  
Stroke  
Voltage - Single Phase  
Minimum Branch Circuit Requirement  
Fuse Type  
Amperage at Maximum Pressure  
Air Tank/Capacity  
Approximate Cut-in Pressure  
Approximate Cut-out Pressure  
SCFM @ 40 psi  
Time Delay  
15.0  
ASME/30 gal. (U.S.)  
100  
125  
7.2  
5.6  
SCFM @ 90 psi  
D21245  
6 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESCRIPTION OF OPERATION  
Air Compressor Pump: To compress air, the piston  
Regulator: The air pressure coming from the air tank is  
controlled by the regulator. The regulator control knob is  
a vibration proof design. Lift the regulator knob to en-  
gage and depress the knob to lock. Turn the regulator  
knob clockwise to increase pressure and counter-clock-  
wise to decrease pressure. To avoid minor readjustment  
after making a change in pressure setting, always ap-  
proach the desired pressure from a lower pressure. When  
reducing from a higher to a lower setting, first reduce to  
some pressure less than that desired, then bring up to  
the desired pressure. Depending on the air requirements  
of each particular accessory, the outlet regulated air pres-  
sure may have to be adjusted while operating the acces-  
sory.  
moves up and down in the cylinder. On the downstroke,  
air is drawn in through the air intake valves. The exhaust  
valves remain closed. On the upstroke of the piston, air  
is compressed. The intake valves close and compressed  
air is forced out through the exhaust valves, through the  
outlet tube, through the check valve and into the air tank.  
Check Valve: When the air compressor is operating, the  
check valve is “open”, allowing compressed air to enter  
the air tank. When the air compressor reaches “cut-out”  
pressure, the check valve “closes”, allowing air pres-  
sure to remain inside the air tank.  
Pressure Switch: The pressure switch is fitted with a  
small lever. It is labeled "Auto/O" for automatic run or  
off. In the "O" position, the motor will not run. In the "Auto"  
position, it automatically starts the motor when the air  
tank pressure drops below the factory set “cut-in” pres-  
sure. It stops the motor when the air tank pressure reaches  
the factory set “cut-out” pressure.  
Regulator Gauge: The outlet pressure gauge indicates  
the air pressure available at the outlet side of the regula-  
tor. This pressure is controlled by the regulator and is  
always less than or equal to the tank pressure. See “Op-  
erating Procedures”.  
Tank Pressure Gauge: The tank pressure gauge indi-  
Pressure Release Valve: The pressure release valve lo-  
cated on the side of the pressure switch is designed to  
automatically release compressed air trapped within the  
compressor head and outlet tube. This short release of  
air will occur when the air compressor reaches "cut-out"  
pressure or the unit is shut off. If the air is not released,  
the motor will not be able to start when next required.  
cates the reserve air pressure in the tank.  
Air Intake Filter: This filter is designed to clean air coming  
into the pump. This filter must always be clean and ventila-  
tion openings free from obstructions. See "Maintenance".  
Drain Valve: This valve is located at the bottom of the  
tank. To drain accumulated moisture from the tank, pull  
on the safety valve until tank pressure is 15 PSI. Un-  
screw the drain valve and allow the water to drain.  
Flow Valve: The flow valve allows air to flow from the  
head as the motor is getting “up to speed”. Once the  
motor reaches normal operating speed, the flow valve  
closes and the pump begins to compress air, thus re-  
quiring less amp draw on initial start.  
Safety Valve: If the pressure switch does not shut off the  
air compressor at its cut-out pressure setting, the safety  
valve will protect the tank against high pressure by “pop-  
ping out” at its factory set pressure (slightly higher than  
the pressure switch cut-out setting).  
TOOLS NEEDED FOR ASSEMBLY  
• a 9/16" socket and an open end wrench for attaching  
the wheels  
• a 3/8" open end wrench or socket to tighten handle  
screws  
D21245  
7 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASSEMBLY  
3. Rotate each retaining clip clockwise and press  
down until it snaps into place over the pull handle  
(Fig. 4).  
It may be necessary to brace or support one  
end of the outfit when attaching the wheels  
because the air compressor will have a  
tendency to tip.  
4. If the handle has excessive movement, it is improp-  
erly installed. Check the following.  
A. Are both tabs inside the handle (Step #1)?  
1. Remove the protective paper strip from the adhe-  
sive backed rubber foot strip. Attack the rubber foot  
strip to the bottom of the air tank leg. Press firmly  
into place.  
B. Does each clip pass through both the saddle  
and handle (Step #2)?  
2. The leg bracket on the underside of the air compres-  
sor tank has 2 holes on each side for mounting the  
wheels. Place one shoulder bolt through the hole in  
a wheel. On models with 10" wheels, push the bolt  
through the TOP hole of the leg bracket. For models  
with 8" wheels, push the bolt through the BOTTOM  
hole of the leg bracket. Screw on one hex locking  
nut. The special locking nut does not turn freely.  
Tighten the nut firmly until it contacts the tank leg.  
The outfit will sit level if the wheels are properly  
installed.  
NOTE  
The side of the wheel, that the hub protrudes  
out past the wheel edge, should be bolted to  
the compressor leg.  
FIG. 2  
FIG. 1  
THE WHEELS AND HANDLE DO NOT PRO-  
VIDE ADEQUATE CLEARANCE, STABILITY  
OR SUPPORT FOR PULLING THE UNIT UP  
AND DOWN STAIRS OR STEPS. THE UNIT  
MUST BE LIFTED OR PUSHED UP A RAMP.  
DO NOT LIFT THE UNIT BY THE MANIFOLD  
ASSEMBLY. THE UNIT CAN BE DAMAGED.  
FIG. 3  
Installing Handle  
FIG. 4  
1. Insert the open end of the handle under the saddle  
(Fig. 1). Before attaching handle, you may have to  
pull the open ends of the handle apart so they fit  
tightly against the side of the saddle. Looking in  
from the open end of the saddle, position the handle  
toward the two bent tabs, on the inside walls of the  
saddle. Slowly push the open ends of the handle  
onto both tabs at the same time (Fig. 2). Continue  
pushing the handle into the saddle until the holes on  
the side of the saddle and handle are in line.  
2. Guide the straight end of each retaining clip through  
the addle hole and both handle holes (Fig. 3).  
D21245  
8 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREAK-IN PROCEDURES  
been installed and grounded in accordance with all  
Location of the Air Compressor  
local codes and ordinances. The outlet must have the  
same configuration as the plug. DO NOT USE AN  
ADAPTER.  
Operate the air compressor in a clean, dry and well  
ventilated area. The fan bladed flywheel must be kept  
clear of obstructions that could interfere with the flow of  
air through the air intake filter. The pump crankcase and  
head are designed with fins to provide proper cooling.  
Inspect the plug and cord before each use. Do not use if  
there are signs of damage.  
If humidity is high, an air filter can be installed on the air  
outlet adapter to remove excessive moisture. Closely  
follow the instructions packaged with the filter for proper  
installation. It must be installed as close as possible to  
the accessory.Do not place the air compressor where  
heat is excessive.  
IMPROPER GROUNDING CAN RESULT IN  
ELECTRICAL SHOCK.  
Do not modify the plug that has been provided. If it  
does not fit the available outlet, the correct outlet  
should be installed by a qualified technician.  
When locating the compressor outside, make sure there  
is a mimum of 12 inches on each side of the compres-  
sor. There must be fresh air flow for proper cooling. DO  
NOT ALLOW THE COMPRESSOR TO GET WET.  
If repairing or replacing cord or plug, the grounding wire  
must be kept separate from the current-carrying wires.  
Never connect the grounding wire to a flat blade plug  
terminal. The grounding wire has insulation with an outer  
surface that is green with or without yellow stripes.  
Lubrication and Oil  
If these grounding instructions are not completely  
understood, or if in doubt as to whether the compressor  
is properly grounded, have the installation checked by a  
qualified electrician.  
Compressors are shipped without oil. Do not  
attempt to operate this air compressor  
without first adding oil to the crankcase.  
Serious damage can result from even limited  
operation unless filled with oil and broken in  
correctly. Make sure to closely follow initial  
start-up procedures.  
Placeunitonalevelsurface.Removeoilfillplugandslowly  
addaspecialcompressoroilsuchasSears9-16426orSAE  
20-20W SF motor oil until it is even with the top of the oil fill  
hole. (It must not be allowed to be lower than 3/8" -- 6  
threads down -- from the top at any time.) When filling the  
crankcase, the oil flows very slowly. If the oil is added too  
quickly, it will overflow and appear to be full. Crankcase oil  
capacity is 16 fluid ounces. Under winter-type conditions  
use SAE 10W oil. Multi-viscosity oil, 10W 30, will leave  
carbon deposits on critical components, reducing perfor-  
mance and compressor life. Replace oil fill plug.  
NOTE  
Drain and refill the compressor pump crank-  
case after the first 100 hours of operation.  
Voltage and Circuit Protection  
Refer to your Specification Chart (page 6) for voltage and  
circuit protection requirements of your compressor. Use  
only a fuse or circuit breaker that is the same rating as  
the branch circuit the air compressor is operated on. If  
the compressor is connected to a circuit protected by  
fuses, use only dual element time delay fuses.  
GROUNDING INSTRUCTIONS  
RISK OF ELECTRICAL SHOCK. In the event  
of a short circuit, grounding reduces the risk  
of shock by providing an escape wire for the  
electric current. This air compressor must be  
properly grounded.  
This portable air compressor is equipped with a cord  
having a grounding wire with an appropriate grounding  
plug. The plug must be used with an outlet that has  
D21245  
9 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
can gather and freeze. Apply pressure before under-  
ground lines are covered to make sure all pipe joints  
are free of leaks.  
Certain air compressors can be converted from  
120V to 240V operation. When converting an  
air compressor to 240V operation, the  
attached three-prong 120V cord assembly  
must be replaced with a three-pronged 240V  
cord assembly that can be purchased through  
a Sears Service Center.  
Connect the piping to the 3/8" NPT air outlet opening  
at the end of the air tank.  
Additional Regulators and Controls  
Some models have a dual voltage motor, 120 and 240  
volt. They are wired for 120 volt but can be converted  
to 240 volt operation. Instructions for connecting the  
motor for operation at 240 volt can be found printed on  
the label attached to the side of the motor.  
Since the air tank pressure is usually greater than that  
which is needed, a separate regulator is employed to  
control the air pressure ahead of any individual air  
driven device.  
Separate air transformers which combine the function  
of air regulation, moisture and dirt removal should be  
used where applicable.  
Certain air compressor models can be operated  
on a 15 amp circuit if:  
Break-in Procedure  
1. Voltage supply to circuit is normal.  
2. Circuit is not used to supply any other electrical  
needs (lights, appliances, etc.)  
3. Extension cords comply with specifications in  
this manual.  
4. Circuit is equipped with a 15 amp circuit  
Serious damage may result if the following  
break-in instructions are not closely fol-  
lowed.  
breaker or 15 amp time delay fuse.  
This procedure is required only once, before the air com-  
pressor is put into service.  
Extension Cords  
1. Set the pressure switch "AUTO/O" lever in the  
"O" position for "Off".  
2. Plug the power cord into the correct branch circuit  
To avoid voltage drop and power loss to the motor, and to  
prevent overheating, use extra air hose instead of an  
extension cord.  
receptacle.  
If an extension cord must be used:  
3. Do not attach hose to outlet. Leave the outlet open  
to the atmosphere.  
4. Turn the regulator clockwise, opening it fully, to  
prevent air pressure build-up in the tank.  
5. Move the "AUTO/O" lever to "AUTO". The com-  
pressor will start.  
6. RUN THE COMPRESSOR FOR 30 MINUTES.  
Make sure the regulator is open and there is no tank  
pressure build-up.  
7. After 30 minutes, close the regulator by turning it  
counterclockwise. The air tank will fill to cut-out  
pressure and then the motor will stop.  
•
use only a 3-wire extension cord that has a 3-  
blade grounding plug and a 3-slot receptacle that  
will accept the plug on the extension cord.  
•
•
make sure the extension cord is in good condition.  
the extension cord should be no longer than 50  
feet.  
•
the minimum wire size is 12 gauge (AWG). (Wire  
size increases as gauge number decreases. 10  
AWG and 8 AWG may also be used. DO NOT USE  
14 AWG or 16 AWG.)  
Piping  
Plastic or PVC pipe is not designed for use with  
compressed air. Regardless of its indicated  
pressure rating, plastic pipe can burst from air  
pressure. Use only metal pipe for air distribution  
lines.  
If a pipe line is necessary, use pipe that is the same  
size as the air tank outlet. Piping that is too small will  
restrict the flow of air. If piping is over 100 feet long,  
use the next larger size. Bury underground lines below  
the frost line and avoid pockets where condensation  
D21245  
10 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING PROCEDURES  
1. Before attaching air hose or accessories, make  
9. Turn the "AUTO/O" lever to “AUTO” and allow tank  
pressure to build. Motor will stop when tank  
pressure reaches “cut-out” pressure.  
sure the "AUTO/O" lever is set to “O” and the air  
regulator is closed.  
2. Make sure that nothing is blocking the belt guard  
air openings or air filter inlet.  
10. Open the regulator by turning it clockwise. Adjust  
the regulator to the correct pressure setting. Your  
compressor is ready for use.  
3. Pull the ring on all safety valve to make sure the  
valve moves freely and smoothly.  
11. Always operate the air compressor in well-venti-  
lated areas; free of gasoline or other solvent  
vapors. Do not operate the compressor near the  
spray area.  
4. Check the oil level; add oil if necessary.  
5. Clean or blow off fins or any part of compressor  
thatcollects dust and dirt. Compressor will run  
cooler and provide longer service.  
WHEN YOU ARE FINISHED:  
12. Set the “AUTO/O” lever to “O”.  
6. Before attaching an air hose or accessory make  
sure the pressure switch lever is in the "OFF"  
position. Close the air regulator outlet by turning it  
counterclockwise.  
13. Turn the regulator counterclockwise and set the  
outlet pressure to zero.  
14. Remove the air tool or accessory.  
7. Attach hose and accessories.  
15. Open the regulator and allow the air to slowly  
bleed from the tank. Close the regulator when  
tank pressure is approximately 20 psi.  
16. Drain water from air tank.  
TOO MUCH AIR PRESSURE CREATES A  
HAZARDOUS RISK OF BURSTING. CARE-  
FULLY FOLLOW STEPS 3 AND 5 BELOW EACH  
TIME THE COMPRESSOR IS USED.  
WATER WILL CONDENSE IN THE AIR TANK. IF  
NOT DRAINED, WATER WILL CORRODE AND  
WEAKEN THE AIR TANK CAUSING A RISK OF  
AIR TANK RUPTURE.  
Compressed air from the outfit may contain  
water condensation. Do not spray unfiltered air  
at an item that could be damaged. Some air  
operated tools or devices may require filtered  
air. Read the instructions for the air tool or  
device.  
NOTE:  
If drain cock valve is plugged, release all air  
pressure. The valve can then be removed,  
cleaned, then reinstalled.  
17. After the water has been drained, close the drain  
valve. The air compressor can now be stored.  
8. Check the manufacturer’s maximum pressure  
rating for air tools and accessories. The regulator  
outletpressure must never exceed the maximum  
pressure rating.  
D21245  
11 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
UNIT CYCLES AUTOMATICALLY WHEN POWER IS ON. WHEN DOING MAINTENANCE, YOU MAY BE EXPOSED TO  
VOLTAGE SOURCES, COMPRESSED AIR OR MOVING PARTS. PERSONAL INJURIES CAN OCCUR. BEFORE  
PERFORMING ANY MAINTENANCE OR REPAIR, UNPLUG THE COMPRESSOR AND BLEED OFF ALL AIR PRES-  
SURE.  
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE DONE BY A QUALIFIED SERVICE TECHNICIAN.  
the old filter. Push in the new air filter. Other models  
require removal of the belt guard and/or filter retainer.  
Routine Maintenance Schedule  
Daily:  
Check Valve Cleaning - Replacement  
1. Check oil level. Add if necessary.  
2. Drain water from the air tank, any moisture separa-  
tors or transformers.  
3. Check for any unusual noise and/or vibration.  
4. Manually check all safety valves to make sure  
they are operating properly.  
Risk of personal injury. Manifold assembly  
contains compressed air which can be  
hazardous.  
Manifold gets hot during operation.  
Before servicing:  
5. Inspect for oil leaks and repair any leaks found.  
6. Inspect air filter, replace if necessary.  
•
Unplug or disconnect electrical supply  
to compressor.  
Bleed tank of pressure.  
Every 40 Hours of Operation:  
1. Clean and inspect the air intake filter; replace if  
•
•
necesssary.  
Allow compressor to cool.  
2. Inspect condition of drive belt; replace if neces-  
sary.  
1. Release all air pressure from air tank and unplug  
outfit.  
Every 100 Hours of Operation:  
2. Remove shroud.  
1. Drain and refill compressor crankcase with 16 fluid  
ounces (473.2 ml) of clean compressor such as  
Sears 9-16426 or SAE 20-20W SF motor oil  
2. Increase frequency of oil changes if humidity or  
operating conditions are extreme.  
3. Loosen the top and bottom nuts and remove the  
outlet tube.  
4. Remove the pressure release tube, fitting, and  
connector.  
Every 160 Hours of Operation:  
5. Unscrew the check valve (turn counterclockwise)  
using a socket wrench.  
1. Check drive belt tension; adjust if necessary.  
(Refer to SERVICE INSTRUCTIONS in this manual.)  
2. Inspect air lines and fittings for leaks; correct as  
necessary.  
3. Check the alignment of the motor pulley to the  
flywheel. If necessary, align to within 1/32 inch on  
centerline.  
6. Check that the valve disc moves freely inside the  
check valve and that the spring holds the disc in  
the upper, closed position. The check valve may  
be cleaned with a solvent, such as paint and  
varnish remover.  
7. Apply a Teflon based pipe sealant to the check  
valve threads. Reinstall the check valve (turn  
clockwise).  
Each Year of Operation or if a Problem  
is Suspected:  
8. Replace the pressure release tube and fitting.  
9. Replace the outlet tube and tighten top and  
bottom nuts.  
Check condition of air compressor pump intake and  
exhaust valves. Replace if damaged or worn out.  
10. Replace the shroud.  
Air Filter - Inspection and Replacement  
Safety Valve - Inspection  
Hot surfaces. Risk of burn. Compressor  
heads are exposed when filter cover is  
removed. Allow compressor to cool prior to  
servicing.  
If the safety valve does not work properly,  
over-pressurization may occur, causing air  
tank rupture or an explosion. Before  
starting compressor, pull the ring on the  
safety valve to make sure that the safety  
valve operates freely. If the valve is stuck or  
does not operate smoothly, it must be  
replaced with the same type of valve.  
A dirty air filter will not allow the compressor to  
operate at full capacity. Before you use the compres-  
sor, check the air filter to be sure it is clean.  
If it is dirty, replace it with a new filter. On some  
models, the filter may be removed by using a pair of  
needle nosed pliers or a screwdriver. Pull or pry out  
D21245  
12 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE  
Belt - Replacement  
If the overload protector shuts the motor  
off frequently, check for a possible voltage  
problem. Low voltage can also be sus-  
pected when:  
SERIOUS INJURY OR DAMAGE MAY OCCUR IF  
PARTS OF THE BODY OR LOOSE ITEMS GET  
CAUGHT IN MOVING PARTS. NEVER OPERATE  
THE OUTFIT WITH THE BELT GUARD RE-  
MOVED. THE BELT GUARD SHOULD BE  
REMOVED ONLY WHEN THE COMPRESSOR IS  
UNPLUGGED.  
1. The motor does not get up to full power or  
speed.  
2. Fuses blow out when the motor is started.  
3. Lights dim when motor is started, and  
remain dim while it is running.  
Belt Guard - Removal and Installation  
1. Move the "ON/AUTO-OFF" lever to the "OFF"  
position. Unplug the compressor. Release all air  
tank pressure.  
2. On one-piece belt guards, remove the two  
beltguard screws on the bottom front of the outfit.  
3. On two-peice belt guards, remove the front of the  
belt guard by disengaging the snaps. Insert a flat  
bladed screwdriver at each snap location and pry  
the beltguard apart.  
Pulley and Flywheel - Alignment  
The compressor flywheel and motor pulley grooves  
must be in-line within 1/32" to assure belt alignment  
within sheave grooves. To check alignment, unplug  
compressor and remove the beltguard. Place a straight  
edge against the outside of the flywheel and measure  
the distance from it to the nearest groove. Alignment is  
achieved when the other end of the straight edge is  
within 1/32" of the measured dimension at the pulley  
grooves.  
Replace Belt  
Servicing Intake and Exhaust Valves  
1. Unplug compressor.  
The intake and exhaust valves as well as the valve  
plates and cylinder head will, over a period of time,  
accumulate a residue of carbon-like material on their  
surfaces. The material will decrease the efficiency of  
the compressor. These components should be in-  
spected whenever a problem is suspected and  
cleaned or replaced with new parts. Refer to "Outfit  
PartsListing", if required. Use the following procedure  
to inspect the parts.  
2. Remove (one-piece) beltguard, or front of (two-  
piece) beltguard as described above.  
NOTE  
Loosen the wing nut at the hold down plate. The  
motor can be tilted to allow for easy removal or  
installation of the belt.  
3. Remove belt and replace.  
NOTE  
1. Unplug compressor and relieve all air pressure  
from the air tank.  
The belt must be centered over the grooves on  
the flywheel and motor pulley.  
2. Disconnect the pressure release and outlet lines  
from the air compressor.  
Adjust Belt Tension  
Adjust belt tension by tightening the wing nut until it  
makes contact with the washer, plus one additional  
turn.  
3. Remove the hardware securing the cylinder head  
and remove the cylinder head and valve plate.  
Pressure Switch - Replacement  
MANY SOLVENTS ARE HIGHLY FLAMMABLE  
AND A HEALTH HAZARD IF INHALED. ALWAYS  
OBSERVE THE SOLVENT MANUFACTURER'S  
SAFETY INSTRUCTIONS AND WARNINGS.  
PRESSURE LOADS BEYOND DESIGN LIMITS  
MAY CAUSE TANK RUPTURE OR EXPLOSION.  
PRESSURE SWITCH OPERATION IS RELATED  
TO MOTOR HP, TANK RATING AND SAFETY  
VALVE SETTING. DO NOT ATTEMPT TO AD-  
JUST, REMOVE OR DEFEAT THE PRESSURE  
SWITCH, OR CHANGE AND MODIFY ANY  
PRESSURE CONTROL RELATED DEVICE. IF  
REPLACEMENT IS NECESSARY, THE SAME  
RATED SWITCH MUST BE USED. CONTACT A  
SEARS SERVICE CENTER FOR REPLACEMENT.  
4. Clean carbon deposits in head cavities and valve  
plates with lacquer thinner or other suitable  
solvent.  
5. Clean the intake and exhaust valves with lacquer  
thinner or other suitable solvent. Inspect valves;  
replace if necessary.  
NOTE  
Do not use gasket cement on any gasket  
surface as this may clog compressor valve  
cavities and air flow areas.  
Motor Overload Protector - Reset  
The motor has a manual thermal overload protector. If  
the motor overheats for any reason, the overload  
protector will shut off the motor. The motor must be  
allowed to cool down before restarting. Turn the unit  
off. To restart, depress the red reset button located on  
the end of the motor and turn ON/AUTO-OFF switch to  
the ON position.  
6. Reinstall valve plate and gaskets.  
7. Install the cylinder head. Snug mounting screws  
and studs tight, then torque to 25 to 30 foot  
pounds starting at the center and working toward  
the outside.  
8. Reconnect the pressure release and outlet lines to  
the compressor pump.  
D21245  
13 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Protect the electrical cord and air hose from  
damage (such as being stepped on or run over).  
Wind them loosely around the outfit handle.  
Storage  
1. Review the "Maintenance" section on the preced-  
ing pages and perform scheduled maintenance as  
necessary. Drain the water from the air tank.  
5. Store the compressor in a clean and dry location.  
2. Set the ON/AUTO-OFF switch to the "OFF" posi-  
tion, and unplug the unit.  
3. Remove any air tool or accessory.  
TROUBLESHOOTING GUIDE  
PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES.  
PERSONAL INJURY MAY OCCUR. PRIOR TO ATTEMPTING ANY REPAIRS, UNPLUG THE COMPRESSOR AND  
BLEED OFF TANK AIR PRESSURE.  
CAUSE  
CORRECTION  
PROBLEM  
Excessive tank pressure - safety  
valve pops off.  
Pressure switch does not shut off  
motor when compressor reaches  
cut-out pressure.  
Move the pressure switch lever to the “O”  
position. If the compressor doesn’t shut off,  
disconnect from the electrical outlet source  
and return to a Sears Service Center to re-  
place the pressure switch.  
Pressure switch cut-out too high.  
Return the compressor to Sears Service Center  
to check and adjust, or replace switch.  
Air leaks at fittings or hose.  
Tube or hose fittings are not tight  
enough.  
Tighten fittings using teflon tape where air  
can be heard escaping. Check fittings with  
soapy water solution. DO NOT OVER-  
TIGHTEN.  
Air leaks at pressure switch  
release valve.  
Defective pressure switch release valve.  
Return to Sears Service Center for replace-  
ment of pressure switch.  
Check to see if the pin in the bottom of the  
pressure release valve is stuck. If it does not  
move freely, return to the Service Center for  
replacement of pressure switch.  
Defective or dirty check valve.  
Defective air tank.  
A defective check valve results in a constant  
air leak at the pressure release valve when  
there is pressure in the tank and the com-  
pressor is shut off. Remove and clean or re-  
place check valve. DO NOT OVERTIGHTEN.  
Air leaks in air tank or at air tank  
welds.  
Air tank must be replaced. Do not repair the  
leak. Return compressor to Sears Service  
Center.  
DO NOT DRILL INTO, WELD OR OTHER-  
WISE MODIFY AIR TANK OR IT WILL  
WEAKEN. THE TANK CAN RUPTURE OR  
EXPLODE.  
Air leaks between head and valve  
plate.  
Leaking seal.  
Torque head screws to 7-10 ft. lbs. If this  
does not stop leak, replace seal.  
D21245  
14 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUSE  
CORRECTION  
PROBLEM  
Pressure reading on the regu-  
lated pressure gauge drops when  
an accessory is used.  
It is normal for some pressure drop  
to occur.  
If there is an excessive amount of pressure  
drop when the accessory is used, adjust the  
regulator.  
NOTE  
Adjust the regulated pressure under flow con-  
ditions (while accessory is being used).  
Operate safety valve manually by pulling on  
ring. If valve still leaks, it should be  
replaced .  
Air leak from safety valve.  
Knocking noise  
Possible defect in safety valve.  
Remove and clean or replace.  
Torque pulley set screw.  
Defective check valve.  
Loose pulley.  
Low oil level.  
Maintain prescribed oil level. Add oil.  
Torque screw 15-20 ft. lbs.  
Loose flywheel.  
Loose compressor mounting screws.  
Check screws. Torque as required (15-20  
ft.-lbs.)  
Loose belt.  
Tighten wing nut until it contacts the  
washer, plus one more turn.  
Adjust belt tension (see "Belt Replace-  
ment".)  
Belt too tight.  
Remove the head and valve plate. Clean  
the valve plate and top of the piston. (Be  
sure carbon does not fall into the cylinder.)  
Reassemble to 25-30 ft. lbs. using new  
gasket and torque screws.  
Carbon build-up.  
Air leaks at or inside check  
valve.  
Defective or dirty check valve.  
A defective check valve results in a constant air  
leak at the pressure release valve when there is  
pressure in the tank and the compressor is shut  
off. Remove and clean or replace check valve.  
DO NOT OVER-TIGHTEN.  
Excessive belt wear.  
Belt is too loose or tight.  
Loose pulley.  
Adjust tension instructions. (See "Belt  
Asjustment or Replacement" section in this  
manual.  
Check for worn keyway or pulley bore. Also  
check for bent motor shaft. Replace parts if  
necessary.  
Motor pulley and flywheel must be in line within  
1/32". (See "Pulley and Flywheel - Alignment"  
section in this manual.)  
Pulley misalignment.  
Squealing sound.  
Loose belt.  
Adjust belt tension. (See "Belt Replacement"  
section in this manual.)  
Add oil to top of fill hole in base.  
There is no oil in the compressor.  
D21245  
15 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROBLEM  
CAUSE  
CORRECTION  
Compressor is not supply-  
ing enough air to operate  
accessories.  
Check the accessory air requirement. If it is higher  
than the SCFM or pressure supplied by your air  
compressor, you need a larger compressor.  
Compressor is not large enough  
for air requirement.  
Clean or replace air intake filter. Do not operate  
the air compressor in any paint spray or drywall  
sanding area.  
Restricted air intake filter.  
Check and replace if required.  
Remove and clean, or replace.  
Hole in hose.  
Check valve restricted.  
Tighten fittings.  
Air leaks.  
Adjust belt tension.  
Loose belt.  
Remove and clean or replace.  
Restricted or defective check valve.  
Motor will not run or restart.  
Present tank pressure exceeds  
pressure switch "cut-in" pressure.  
Motor will start automatically when tank pressure  
drops below "cut-in" pressure of pressure switch.  
Fuse blown, circuit breaker tripped.  
1. Check fuse box for blown fuse and replace, if  
necessary. Reset circuit breaker. Do not use a  
fuse or circuit breaker with higher rating than  
that specified for your particular branch circuit.  
2. Check for proper fuse; only Time Delay fuses  
are acceptable.  
3. Check for low voltage conditions and/or  
proper extension cord.  
4. Disconnect the other electrical appliances  
from circuit or operate the compressor on its  
own branch circuit.  
5. Check for loose electrical connections.  
Motor overload protection switch  
has tripped.  
Let motor cool off and overload switch will  
auto- matically reset.  
Return to Sears Service Center for inspection or  
replacement, if necessary.  
Possible defective motor or  
capactior.  
Have compressor checked at Sears Service Center.  
Do not operate the compressor in the paint spray  
area. See flammable vapor warning.  
Paint spray on internal motor  
parts.  
Check valve stuck open, putting  
pressure on head.  
Remove and clean, or replace the check valve.  
Pressure release valve on pressure  
switch has not unloaded head  
pressure.  
Bleed the line by pushing the lever on the pressure  
switch to the "O" position; if the valve does not  
open, replace it.  
Regulator knob continuous  
air leak. Regulator will not  
shut off at air outlet.  
Dirty or damaged regulator  
internal parts.  
Replace regulator.  
D21245  
16 — ENG  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNERS MANUAL FOR  
CRAFTSMAN  
MODEL NO.  
SERVICE  
PERMANENTLY LUBRICATED  
TANK MOUNTED  
AIR COMPRESSOR  
The model number of your Sears Air Compressor can be  
found  
on the maintenance label on the top of the shroud or on the  
bar code label on the rear of the air tank.  
SERVICE AND REPAIR PARTS  
CALL 1-800-665-4455*  
Keep this number handy should you require a service call or  
need to order repair parts.  
If ordering parts make sure you have the name, make and  
model no. of the merchandise and the name and number of  
the part you wish to order.  
*If calling locally, please use one of the following num-  
bers:  
Regina  
- 566-5124  
Montreal - 333-5740  
Toronto - 744-4900  
Kitchener - 894-7590  
Halifax  
Ottawa  
- 454-2444  
- 738-4440  
Vancouver - 420-8211  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE  
FOLLOWING INFORMATION:  
HOW TO ORDER  
REPAIR PARTS  
• PART NUMBER  
• PART DESCRIPTION  
• NAME OF ITEM  
• MODEL NUMBER  
All parts listed may be ordered from any Sears Service Center  
and most Sears stores.  
If the parts you need are not stocked locally, your order will be  
electronically transmitted to a Sears Repair Parts Distribution  
Center for handling.  
Sold By Sears Canada, Inc., Toronto, Ont. M5B 2B8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CRAFTSMAN  
MANUEL D'INSTRUCTIONS  
COMPRESSEUR D’AIR  
CRAFTSMAN  
MONTÉ SUR RÉSERVOIR  
N° de modèle  
919.728000  
Inscrire à l’endroit désigné:  
1) Le numéro de modèle indiqué sur  
l’étiquette d’entretien apposée sur le  
moteur ou sur l’étiquette du code  
à barres située à l’arrière du réservoir.  
2) Le numéro de code de date indiqué  
sur l’étiquette apposée à l’arrière du  
réservoir d'air.  
3) Le numéro de série indiqué sur  
l’étiquette apposée à l’arrière du  
réservoir d'air.  
4) Le numéro d’enregistrement du  
réservoir indiqué sur la plaque  
signalétique métallique située à  
l’arrière du réservoir. Cette plaque  
est peinte de la même couleur que  
le réservoir.  
Noter ces numéros pour référence.  
Consignesde  
sécurité  
IMPORTANT:  
Numéro de modèle______________________  
Numéro de série________________________  
Code de date___________________________  
Numéro du réservoir____________________  
Assemblage  
Utilisation  
Entretien  
Dépannage  
Pièces  
Lireattentivementlesdirectives  
de sécurité et le mode d’emploi  
avantd’utiliserl’appareil.  
Vendu par Sears Canada Inc., Toronto, Ontario M5B 2B8  
D21245 Rev. 4 7/18/01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE DES MATIÈRES  
GARANTIE ........................................................... 2  
MISE EN MARCHE ...................................................... 9  
CONSIGNES DE SÉCURITÉ .............................. 2  
SYMBOLES DE MISE EN GARDE ................ 3-5  
INFORMATION GÉNÉRALE ............................... 6  
GLOSSAIRE ......................................................... 6  
TABLEAU DES SPÉCIFICATIONS .................... 6  
DESCRIPTION DU FONCTIONNEMENT ....... 7  
OUTILS NÉCESSAIRES À L’ASSEMBLAGE .... 7  
ASSEMBLAGE ..................................................... 7  
ENTRETIEN.................................................................... 10  
Filtre à air - Inspection et remplacement .................... 10  
Clapet de retenue - Inspection et remplacement ..... 10  
Soupape de sûreté - Inspection et remplacement.... 10  
Moteur........................................................................ 10  
Entreposage ............................................................... 10  
GUIDE DE DÉPANNAGE.........................................11-12  
SCHÉMA - APPAREIL ................................................... 13  
LISTE DES PIÈCES...................................................... 14  
SCHÉMA - BLOC COMPRESSEUR ............................. 15  
LISTE DES PIÈCES - BLOC COMPRESSEUR ........... 16  
NOTES ........................................................................... 17  
COMMANDE DE PIÈCES ................ Couverture arrière  
PROCÉDÉSDERODAGE ................................. 8-9  
Emplacement du compresseur ..................... 8  
Lubrification et huile ...................................... 8  
Mise à la masse .............................................. 8  
Tension et protection du circuit ....................... 8  
Directives de rodage ....................................... 9  
GARANTIECOMPLÈTED'UNANSURLESCOMPRESSEURS  
D'AIRSEARS  
Si ce compresseur fait défaut, au cours de l'année suivant la date d’achat, pour cause de  
défaut de matériau ou main-d’oeuvre, LE RETOURNER À L’UN DES MAGASINS SEARS LE  
PLUS PROCHE QUI LE RÉPARERA GRATUITEMENT.  
Si le compresseur est utilisé à des fins commerciales ou de location, cette garantie se limite  
à 90 jours à partir de la date d’achat.  
Cette garantie est complémentaire à toute autre garantie statutaire qui peut varier d'une  
province à l'autre.  
SEARS CANADA INC, TORONTO ONT. M5B 2B8  
MESURES DE SÉCURITÉ - DÉFINITIONS  
Ce guide contient des renseignements importants que vous devez bien saisir. Cette information porte sur VOTRE SÉCURITÉ et sur LA PRÉVENTION  
DE PROBLÈMES D’ÉQUIPEMENT. Afin de vous aider à identifier cette information, nous avons utilisé des signes de danger plus bas. Veuillez lire  
attentivement ce guide en portant une attention particulière à ces sections. CONSERVEZ CES DÉFINITIONS/INSTRUCTIONS.  
MISE EN GARDE  
MISE EN GARDE : Indique la possibilité d’un danger qui, s’il  
n’est pas évité peut causer des blessures mineures ou  
moyennes.  
DANGER  
DANGER : Indique un danger imminent qui, s'il n'est pas évité,  
causera de graves blessures ou la mort.  
AVERTISSEMENT  
AVERTISSEMENT : Indique la possibilité d’un danger qui, s’il  
n’est pas évité, pourrait causer de graves blessures ou la  
mort.  
MISE EN GARDE  
MISE EN GARDE (sans le symbole d'attention) : Indique la  
possibilité d'un danger qui, s'il n'est pas évité, peut causer des  
dommages à la propriété.  
2 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MESURES DE SÉCURITÉ IMPORTANTES  
CONSERVER CES DIRECTIVES  
AVERTISSEMENT  
UN EMPLOI OU UN ENTRETIEN NON APPROPRIÉS DE CE PRODUIT PEUT CAUSER DES BLESSURES GRAVES ET DES DOMMAGES  
À LA PROPRIÉTÉ. LIRE ATTENTIVEMENT TOUS LES AVERTISSEMENTS ET LES DIRECTIVES D’UTILISATION AVANT D’UTILISER CET  
APPAREIL.  
DANGER  
RISQUE D’EXPLOSION OU D’INCENDIE  
RISQUE  
PRÉVENTION  
LES ÉTINCELLES QUI PROVIENNENT DES CONTACTS ÉLECTRIQUES DU  
MOTEUR ET DU MANOSTAT SONT CONSIDÉRÉES NORMALES.  
TOUJOURS UTILISER LE COMPRESSEUR DANS UN ENDROIT BIEN AÉRÉ,  
LOIN DE TOUTE MATIÈRE COMBUSTIBLE ET DES VAPEURS D’ESSENCE OU  
DE SOLVANTS.  
SI DES ÉTINCELLES ÉLECTRIQUES DU COMPRESSEUR ENTRENT EN CONTACT  
AVEC DES VAPEURS INFLAMMABLES, ELLES PEUVENT S’ENFLAMMER,  
PROVOQUANT UN INCENDIE OU UNE EXPLOSION.  
SI DES MATIÈRES INFLAMMABLES DOIVENT ÊTRE VAPORISÉES, SITUER LE  
COMPRESSEUR À UNE DISTANCE D’AU MOINS 20 PIEDS DE LA ZONE DE  
VAPORISATION. IL PEUT S’AVÉRER NÉCESSAIRE D’UTILISER UN BOYAU  
SUPPLÉMENTAIRE.  
ENTREPOSER LES MATIÈRES INFLAMMABLES DANS UN ENDROIT  
SÉCURITAIRE, LOIN DU COMPRESSEUR.  
NE JAMAIS PLACER DES OBJETS CONTRE OU SUR LE COMPRESSEUR.  
UTILISER LE COMPRESSEUR DANS UN ENDROIT OUVERT, À AU MOINS 12  
POUCES (30 cm) DE TOUT MUR OU OBSTRUCTION QUI RÉDUIT LE DÉBIT  
D’AIR FRAIS VERS LES ORIFICES D’AÉRATION.  
TOUTE OBSTRUCTION DES ORIFICES D’AÉRATION DU COMPRESSEUR  
ENTRAÎNERA UNE SURCHAUFFE DANGEREUSE ET RISQUE DE CAUSER UN  
INCENDIE.  
UTILISER LE COMPRESSEUR DANS UN ENDROIT PROPRE. NE PAS UTILISER  
L’APPAREIL À L’INTÉRIEUR OU DANS UN ENDROIT CLOS.  
.
SI CET APPAREIL FONCTIONNE SANS SUPERVISION, CELA RISQUE DE  
CAUSER DES BLESSURES GRAVES OU DES DOMMAGES À LA PROPRIÉTÉ.  
TOUJOURS RESTER À PROXIMITÉ DE L’APPAREIL LORSQU’IL EST EN  
FONCTION.  
RISQUE D’ÉCLATEMENT  
RÉSERVOIR D’AIR : LES CONDITIONS SUIVANTES PEUVENT AFFAIBLIR LES PAROIS DU RÉSERVOIR ET PROVOQUER UNE  
EXPLOSION VIOLENTE DU RÉSERVOIR QUI RISQUE DE CAUSER DES DOMMAGES À LA PROPRIÉTÉ  
OU DES BLESSURES GRAVES.  
RISQUE  
PRÉVENTION  
1. LE DÉFAUT DE VIDANGER DE FAÇON APPROPRIÉE L’EAU CONDENSÉE  
DANS LE RÉSERVOIR RISQUE DE CAUSER LA ROUILLE ET L’AMINCISSEMENT  
DES PAROIS EN ACIER DU RÉSERVOIR.  
PURGER LE RÉSERVOIR QUOTIDIENNEMENT OU APRÈS CHAQUE  
UTILISATION. SI LE RÉSERVOIR ACCUSE UNE FUITE, LE REMPLACER  
IMMÉDIATEMENT PAR UN NOUVEAU RÉSERVOIR OU REMPLACER LE  
COMPRESSEUR AU COMPLET.  
2. DES MODIFICATIONS OU TENTATIVES DE RÉPARATION FAITES SUR LE  
RÉSERVOIR.  
NE JAMAIS PERFORER AVEC UNE PERCEUSE, SOUDER OU FAIRE UNE  
MODIFICATION QUELCONQUE AU RÉSERVOIR OU À SES ACCESSOIRES.  
3. DES MODIFICATIONS NON AUTORISÉES APPORTÉES À LA SOUPAPE DE  
DÉCHARGE, À LA SOUPAPE DE SÛRETÉ OU À TOUTE AUTRE COMPOSANTE  
QUI CONTRÔLE LA PRESSION DU RÉSERVOIR.  
LE RÉSERVOIR EST CONÇU POUR SUBIR DES PRESSIONS DE SERVICE  
PARTICULIÈRES. NE JAMAIS EFFECTUER DES RÉGLAGES NI SUBSTITUER  
DES PIÈCES POUR MODIFIER LES PRESSIONS DE SERVICE ÉTABLIES À  
L’USINE.  
4. DES VIBRATIONS EXCESSIVES PEUVENT AFFAIBLIR LE RÉSERVOIR ET  
CAUSER UNE RUPTURE OU UNE EXPLOSION. DES VIBRATIONS EXCESSIVES  
SERONT PRODUITES SI LE COMPRESSEUR N’EST PAS FIXÉ DE FAÇON  
APPROPRIÉE.  
FIXATIONS ET ACCESSOIRES :  
POUR LE CONTRÔLE ESSENTIEL DE LA PRESSION D’AIR, IL FAUT POSER UN  
RÉGULATEUR DE PRESSION ET UN MANOMÈTRE À LA SORTIE D’AIR DU  
COMPRESSEUR. SUIVRE LES RECOMMANDATIONS DU FABRICANT DE  
L’ÉQUIPEMENT ET NE JAMAIS EXCÉDER LA VALEUR NOMINALE DE PRESSION  
SPÉCIFIÉE DES ACCESSOIRES. NE JAMAIS UTILISER LE COMPRESSEUR POUR  
GONFLER DES OBJETS À FAIBLE PRESSION, TELS QUE LES JOUETS  
D’ENFANT, LES BALLONS DE FOOTBALL OU DE BASKET-BALL, ETC.  
LE FAIT D’EXCÉDER LA PRESSION NOMINALE DES OUTILS PNEUMATIQUES,  
PISTOLETSPULVÉRISATEURS, ACCESSOIRESPNEUMATIQUES, PNEUSETAUTRES  
OBJETS GONFLABLES RISQUE DE PROVOQUER L’EXPLOSION DE CES  
DERNIERS ET LA PROJECTION DE PIÈCES, CE QUI RISQUE DE CAUSER DE  
GRAVES BLESSURES.  
3 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
RISQUE DE PROJECTION D’OBJETS  
RISQUE  
PRÉVENTION  
LE JET D’AIR COMPRIMÉ PEUT CAUSER DES LÉSIONS AUX TISSUS DE  
LA PEAU EXPOSÉE ET PEUT PROJETER DE LA SALETÉ, DES COPEAUX, DES  
PARTICULES LIBRES ET DE PETITS OBJETS À HAUTE VITESSE, CE QUI  
RISQUE DE CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES.  
PORTER TOUJOURS DES LUNETTES DE PROTECTION HOMOLOGUÉES  
ANSI Z87.1 AVEC DES ÉCRANS LATÉRAUX LORS DE L’UTILISATION DU  
COMPRESSEUR.  
NE JAMAIS DIRIGER LA BUSE OU LE PULVÉRISATEUR VERS SOI, VERS  
D’AUTRES PERSONNES OU VERS DES ANIMAUX.  
TOUJOURS METTRE LE COMPRESSEUR HORS FONCTION ET PURGER LA  
PRESSION DU BOYAU D’AIR ET DU RÉSERVOIR AVANT D’ENTAMER  
L’ENTRETIEN OU D’ATTACHER DES OUTILS OU ACCESSOIRES.  
RISQUE PAR INHALATION  
RISQUE  
PRÉVENTION  
L’AIR COMPRIMÉ DE VOTRE COMPRESSEUR D’AIR N’EST PAS SÉCURITAIRE  
POUR L’INHALATION. LE JET D’AIR PEUT CONTENIR DU MONOXYDE DE  
CARBONE, DES VAPEURS TOXIQUES OU DES PARTICULES SOLIDES DU  
RÉSERVOIR.  
TOUJOURS UTILISER LE COMPRESSEUR D’AIR À L’EXTÉRIEUR, DANS UN  
ENDROIT PROPRE ET BIEN AÉRÉ. ÉVITER DES ENDROITS CLOS TELS QUE  
GARAGES, SOUS-SOLS ET HANGARS D’ENTREPOSAGE QUI NE SONT PAS  
DOTÉS DE SYSTÈMES D’ÉCHANGE D’AIR. GARDER LES ENFANTS, LES  
ANIMAUX DOMESTIQUES ET AUTRES, LOIN DE LA ZONE DE TRAVAIL.  
NE JAMAIS INHALER L’AIR ÉMIS PAR LE COMPRESSEUR, QUE CE SOIT  
DIRECTEMENT OU AU MOYEN D’UN DISPOSITIF RESPIRATEUR BRANCHÉAU  
COMPRESSEUR.  
LES MATIÈRES VAPORISÉES TELLES QUE LA PEINTURE, LES SOLVANTS DE  
PEINTURE, LES DÉCAPANTS, LES INSECTICIDES ET LES HERBICIDES  
CONTIENNENT DES VAPEURS NOCIVES ET TOXIQUES.  
TRAVAILLER DANS UN ENDROIT OÙ IL Y A UNE BONNE VENTILATION  
TRANSVERSALE. BIEN LIRE ET RESPECTER LES DIRECTIVES DE SÉCURITÉ  
INDIQUÉES SUR L’ÉTIQUETTE OU LA FICHE SIGNALÉTIQUE DE LA MATIÈRE  
QUI EST VAPORISÉE. PORTER UN RESPIRATEUR HOMOLOGUÉ PAR LE  
NIOSH/MSHA ET CONÇU POUR L’APPLICATION EN QUESTION.  
RISQUE DE CHOC ÉLECTRIQUE  
RISQUE  
PRÉVENTION  
VOTRE COMPRESSEUR D’AIR EST ALIMENTÉ PAR ÉLECTRICITÉ. COMME  
AVEC TOUS LES APPAREILS ÉLECTRIQUES, SI L’APPAREIL N’EST PAS  
UTILISÉ DE FAÇON APPROPRIÉE, IL PEUT CAUSER DES CHOCS  
ÉLECTRIQUES.  
NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR ÀL’EXTÉRIEUR  
LORSQU’IL PLEUT OU DANS DES CONDITIONS HUMIDES.  
NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR SANS LES  
COUVERCLES OU LORSQUE CEUX-CI SONT ENDOMMAGÉS.  
TOUT CÂBLAGE ÉLECTRIQUE OU TOUTE RÉPARATION REQUIS SUR CET  
APPAREIL DEVRAIT ÊTRE EFFECTUÉ PAR LE PERSONNEL D’UN CENTRE  
DE SERVICE APRÈS-VENTE AUTORISÉ, CONFORMÉMENT AUX CODES  
ÉLECTRIQUES NATIONAUX ET LOCAUX.  
TOUTE RÉPARATION EFFECTUÉE PAR UNE PERSONNE NON QUALIFIÉE  
PEUT ENTRAÎNER DES BLESSURES GRAVES OU LA MORT PAR  
ÉLECTROCUTION.  
S’ASSURER QUE LE CIRCUIT ÉLECTRIQUE ALIMENTANT LE COMPRESSEUR  
FOURNIT UNE MISE À LA TERRE ÉLECTRIQUE APPROPRIÉE, UNE  
TENSION APPROPRIÉE ET UNE PROTECTION ADÉQUATE PAR FUSIBLES.  
MISE À LA TERRE : LE DÉFAUT D’ÉTABLIR UNE MISE À LA TERRE  
APPROPRIÉE POUR CET APPAREIL PEUT ENTRAÎNER DES BLESSURES  
GRAVES OU LA MORT PAR ÉLECTROCUTION. VOIR LES DIRECTIVES DE  
MISE À LA TERRE.  
4 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
RISQUE RELIÉ AUX PIÈCES MOBILES  
RISQUE  
PRÉVENTION  
LES PIÈCES MOBILES TELLES QUE LA POULIE, LE VOLANT-MOTEUR ET LA  
COURROIE PEUVENT ENTRAÎNER DES BLESSURES GRAVES SI ELLES  
ENTRENT EN CONTACT AVEC UNE PARTIE DU CORPS OU DES VÊTEMENTS.  
NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR SANS LES GARDES  
OU LES COUVERCLES OU LORSQUE CEUX-CI SONT ENDOMMAGÉS.  
EN TENTANT DE FAIRE FONCTIONNER LE COMPRESSEUR AVEC DES  
PIÈCES MANQUANTES OU ENDOMMAGÉES, OU DE RÉPARER LE  
COMPRESSEUR SANS LES GARDES DE PROTECTION, ON S’EXPOSE AUX  
PIÈCES MOBILES, CE QUI PEUT ENTRAÎNER DES BLESSURES GRAVES.  
TOUTE RÉPARATION REQUISE SUR CET APPAREIL DEVRAIT ÊTRE  
EFFECTUÉE PAR LE PERSONNEL D’UN CENTRE DE SERVICE APRÈS-  
VENTE AUTORISÉ.  
RISQUE DE BRÛLURES  
RISQUE  
PRÉVENTION  
LE FAIT DE TOUCHER AUX SURFACES DE MÉTAL EXPOSÉES TELLES QUE  
LA TÊTE DU COMPRESSEUR OU LES TUBES DE SORTIE PEUT CAUSER DE  
GRAVES BRÛLURES À LA PEAU.  
NE JAMAIS TOUCHER AUX PIÈCES DE MÉTAL EXPOSÉES DU MOTEUR  
OU DU COMPRESSEUR DURANT OU IMMÉDIATEMENT APRÈS LE  
FONCTIONNEMENT. LE MOTEUR ET LE COMPRESSEUR DEMEURENT  
CHAUDS PENDANT PLUSIEURS MINUTES APRÈS LEUR FONCTIONNEMENT.  
LA TÊTE DU COMPRESSEUR ET LES TUBES DEVIENNENT TRÈS CHAUDS LORS  
DUFONCTIONNEMENT.  
NE PAS TENTER D’ATTEINDRE LES COMPOSANTES DERRIÈRE LES GARDES DE  
PROTECTION ET NE PAS EFFECTUER DE L’ENTRETIEN AVANT D’AVOIR LAISSÉ  
REFROIDIR L’APPAREIL.  
RISQUE DE CHUTE  
RISQUE  
PRÉVENTION  
UN COMPRESSEUR PORTATIF PEUT TOMBER D’UNE TABLE, D’UN ÉTABLI OU  
D’UN TOIT. L’IMPACT PEUT CAUSER DES DOMMAGES AU COMPRESSEUR  
ET DES BLESSURES CORPORELLES OU LA MORT DE L’UTILISATEUR.  
TOUJOURS S’ASSURER DE LA STABILITÉ DU COMPRESSEUR AVANT DE LE  
FAIRE FONCTIONNER AFIN DE PRÉVENIR TOUT MOUVEMENT ACCIDENTEL DE  
L’APPAREIL. NE JAMAIS UTILISER UN COMPRESSEUR SUR UN TOIT OU  
DANS UNE POSITION ÉLEVÉE ; UTILISER PLUTÔT UN BOYAU D’AIR  
SUPPLÉMENTAIRE POUR ATTEINDRE LES ENDROITS ÉLEVÉS.  
RISQUE DE DOMMAGES À LA PROPRIÉTÉ PENDANT LE  
TRANSPORT DU COMPRESSEUR  
(incendie, inhalation, dommages aux surfaces du véhicule)  
RISQUE  
PRÉVENTION  
DES FUITES OU DES DÉVERSEMENTS D’HUILE PEUVENT SE  
PRODUIRE ET ENTRAÎNER DES RISQUES D’INCENDIE, OU DES  
PROBLÈMES AUX VOIES RESPIRATOIRES, DES BLESSURES GRAVES  
OU LA MORT. DES FUITES D’HUILE ENDOMMAGENT LES TAPIS, LA  
PEINTURE ET TOUTE AUTRE SURFACE DES VÉHICULES OU DES  
REMORQUES.  
TOUJOURS PLACER LE COMPRESSEUR SUR UN TAPIS DE  
PROTECTION POUR ÉVITER L’ENDOMMAGEMENT DU VÉHICULE PAR  
DES FUITES. RETIRER LE COMPRESSEUR DU VÉHICULE  
IMMÉDIATEMENT À L’ARRIVÉE.  
ESW-99 — 9/26/99  
5 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFORMATION GÉNÉRALE  
Vous avez fait l’achat d’un compresseur d’air muni d’une  
Un filtre à air en ligne qui élimine l’humidité et les vapeurs  
d’huile dans l’air comprimé est généralement nécessaire  
lorsqu’un pistolet à peindre est employé.  
pompe de compresseur d’air à phase unique, de 2 cylindres  
en aluminium (avec chemises en fonte), d’un réservoir d’air, de  
roues, d'une poignée et de dispositifs et contrôles associés.  
Un lubrificateur en ligne est habituellement requis pour les  
outils pneumatiques afin de prolonger la durée de vie utile de  
l’outil.  
Votre compresseur d’air peut être utilisé avec des pistolets à  
peindre, des outils pneumatiques, des pistolets à calfeutrer,  
des pistolets graisseurs, des pinceaux vaporisateurs, des  
sableuses ainsi que pour le gonflage de pneus et de jouets en  
plastique ou pour la vaporisation de pesticides, d’insecticides,  
etc… Un régulateur de pression d’air est requis pour la plupart  
de ces applications.  
Un condensateur d’air distinct qui combine les fonctions du  
régulateur d’air et de l’enlèvement de l’humidité et de la saleté  
devrait être utilisé au besoin.  
GLOSSAIRE  
CFM: (Cubic feet per minute) pi.cu.par minute  
Point de consigne d’arrêt du pressostat: Quand on  
met en fonctionnement le compresseur, la pression à  
l’intérieur du réservoir augmente jusqu’à un certain  
niveau auquel le compresseur s’arrête, protégeant  
ainsi le réservoir de pressions excessives. Ce niveau  
est appelé “point d’arrêt du pressostat” (Cut-out  
pressure)  
SCFM: (standard CFM) pi.cu/min. standard. C’est une  
mesure du débit d'air.  
PSI: (Pounds per square inch) lbs./po.ca., unité de  
mesure de pression.  
ASME: American Society of Mechanical Engineers.  
L’équipement est fabriqué et testé conformément aux  
standards ASME.  
ACNOR: Les appareils électriques vendus au Canada  
doivent porter la certification de l’Acnor. L’Acnor est  
l’Association canadienne de normalisation. C’est elle qui  
établit les normes de sécurité et qui effectue les  
vérifications. L’équipement Sears certifié Acnor dépasse  
souvent les normes électriques et sécuritaires exigées  
par l’ACNOR.  
Point de déclenchement du pressostat: Quand le  
moteur est à l’arrêt, la pression à l’intérieur du réservoir  
diminue au fur et à mesure qu’on utilise les accessoires.  
Quand la pression à l’intérieur du réservoir baisse  
au-dessous d’un certain niveau, le moteur redémarre  
automatiquement. Ce niveau est appelé “point de  
déclenchement du pressostat” (Cut-in pressure)  
TABLEAU DES SPÉCIFICATIONS  
N° de modèle  
Alésage  
Course  
919.728000  
2 3/8 po  
1.35 po  
Tension - monophasée  
120/240  
Capacité minimum du branchement électrique  
15 A  
Type de fusible  
Ampérage à la pression maximum  
Capacité du réservoir d’air  
Point de déclenchement du pressostat (marche)  
Point d'arrêt du pressostat (arrêt)  
SCFM (pi.cu./min.std).@ 40 psi  
SCFM (pi.cu./min.std).@ 90 psi  
à action différée  
15 A  
ASME / 30 gal.  
100 psi  
125 psi  
7.2  
É.-U.  
5.6  
6 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESCRIPTION DU FONCTIONNEMENT  
Pompe de compresseur d'air : Pour comprimer l’air, le  
Régulateur de pression : La pression de l’air arrivant du  
réservoir est contrôlée par le bouton du régulateur. Le  
bouton est du type insensible aux vibrations. Tirer le  
bouton vers le haut pour modifier la pression et le presser  
vers le bas pour le bloquer. Tourner le bouton dans le  
sens des aiguilles d’une montre pour augmenter la  
pression, et le tourner dans le sens inverse pour la  
diminuer. Pour éviter les rajustements nécessaires quand  
on change le point de déclenchement, commencer par  
une pression inférieure pour atteindre la pression de  
réglage désirée. Si vous partez d’un point de pression  
supérieur à celui désiré, descendez plus bas que ce  
dernier et remontez pour atteindre le point désiré. La  
pression de sortie pour un outil devra tenir compte des  
exigences de celui-ci et devra probablement être réglée  
pendant son fonctionnement.  
piston se meut de bas en haut et vice versa, dans le  
cylindre. Pendant la descente du piston, l'air est aspiré  
dans les soupapes d'admission. Les soupapes  
d'échappement demeurent fermées. Pendant la montée  
du piston, l'air est comprimé. Les soupapes d'admission  
se ferment et l'air comprimé est aspiré dans les soupapes  
d'échappement et ensutie dans le tuyau de sortie, le  
clapet de retenue et dans le réservoir d'air.  
Clapet de retenue : Quand le compresseur fonctionne,  
le clapet de retenue est ouvert permettant ainsi à l’air  
comprimé de passer dans le réservoir. Quand le  
compresseur s’arrête au point d’arrêt, le clapet de  
retenue se ferme, empêchant le retour d’air du réservoir.  
Pressostat : Le pressostat est muni d’un petit levier et  
d’une étiquette indiquant “Auto/O”. À la position “O” le  
compresseur ne fonctionne pas. À la position “Auto”, le  
pressostat met en marche automatiquement le moteur  
quand la pression dans le réservoir baisse au-dessous  
du point de déclenchement. Il arrête le moteur quand la  
pression du réservoir atteint le point d’arrêt du pressostat.  
Manomètre du détendeur : Le manomètre de sortie  
indique la pression de l’air sortant du détendeur vers  
l’outil. Cette pression est contrôlée par le détendeur et est  
toujours égale ou inférieure à la pression du réservoir (Voir  
“Mise en marche”).  
Manomètre du réservoir : Le manomètre du réservoir  
indique la pression d'air dans le réservoir.  
Détendeur de pression : Le détendeur de pression situé  
du côté du prressostat, est conçu pour libérer  
automatiquement l'air comprimé de la culasse du  
compresseur et du tuyau de sortie lorsque le «point  
d'arrêt» est atteint dans le compresseur ou que celui-ci  
est fermé. Si l'air n'est pas libéré, le moteur tentera de  
démarrer mais ne pourra le faire.  
Filtre d’admission d’air : Ce filtre a été conçu pour  
purifierl’airquientredanslapompe.Cefiltredoittoujours  
être propre et les évents libres de toutes obstructions.  
VoirEntretien.  
Vanne de vidange : La vanne est située au bas du  
réservoir et sert à vidanger l’eau de condensation qui  
s’est accumulée dans le réservoir. Pour vidanger, dégager  
la pression par la vanne de sûreté jusqu’à 15 psi.  
Dévisser ensuite la vanne de vidange pour vidanger  
l’eau.  
Valve de décharge : Cette valve permet d’évacuer l’air  
de la culasse du compresseur, au démarrage, jusqu’à ce  
que le compresseur atteigne sa vitesse de croisière. À ce  
moment, la valve se ferme et le compresseur comprime  
l’air. Ce dispositif réduit l’ampérage au démarrage.  
Soupape de sûreté : Si le pressostat n’arrête pas le  
compresseur au point d’arrêt, la soupape de sûreté  
protège l’unité contre des pressions excessives en  
faisant évacuer l’air à un point de pression préalablement  
fixé par le fabricant de la soupape (légèrement supérieur  
au point d'arrêt.  
OUTILS NÉCESSAIRES À L’ASSEMBLAGE  
• Douille 9/16 po et clé ouverte pour enlever les cartons  
• Clé ouverte ou douille 3/8 po pour fixer les vis de la  
poignée.  
d'emballage.  
7 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASSEMBLAGE  
Installation des roues, poignées et bande de  
caoutchouc à la base  
4. Si la poignée a trop de jeu, elle n’est pas bien installée. Vérifiez les  
points suivants :  
A. Est-ce que les pattes sont toutes deux àl’intérieur de la poignée  
(étape no : 1) ?  
Il peut être nécessaire de soutenir ou de consolider  
une extrémité de l’appareil lors de la fixation des roues  
en raison de la tendance du compresseur à basculer.  
B.Est-ce que les brides de retenue passe à travers le chevalet et  
la poignée (étape no : 2) ?  
1. Retirez la bande de protection en papier de l’endos de la bande  
en caoutchouc autocollante. Appliquez la bande en  
caoutchouc à la base des pattes du réservoir d’air. Appuyez  
fermement pour fixer.  
2. La fixation de la patte située sous l’autre côté du réservoir  
d’air comprend 2 orifices de chaque côté pour le montage  
des roues. Placez un boulon d’épaulement dans l’orifice de la  
roue. Sur les modèles munis de roues de 10 po (25,4 cm),  
passez le boulon à travers l’orifice DU HAUT de la fixation de  
la patte. Sur les modèles munis de roues de 8 po (20,32 cm),  
passez le boulon à travers l’orifice DU BAS de la fixation de la  
patte. Vissez un contre-écrou à six pans. Le contre-écrou  
spécial ne tourne pas librement. Serrez l’écrou fermement  
jusqu’à ce qu’il touche à la patte du réservoir. L’appareil sera  
stable si les roues sont bien installées.  
EXTRÉMITÉ  
OUVERTE DU  
CHEVALET  
ORIFICE DU  
CHEVALET  
ORIFICE DE  
LA POIGNÉE  
PATTES  
REPLIÉES  
EXTRÉMITÉOUVERTE  
DELAPOIGNÉE  
EXTRÉMITÉ  
OUVERTE DE LA  
POIGNÉE  
PATTES  
REPLIÉES  
CHEVALET  
SCHÉMA 2  
SCHÉMA 1  
REMARQUE  
C’est le côté où l’essieu dépasse la roue qui doit être  
boulonné à la patte du compresseur.  
BRIDES DE  
RETENUE  
BRIDES  
DE RETENUE  
POIGNÉE  
INSÉRÉE SUR  
CARTER DE  
LA COURROIE  
POIGNÉE  
LES PATTES  
LES ROUES ET LA POIGNÉE N’OFFRENT PAS UN  
ESPACE DE DÉGAGEMENT, LA STABILITÉ OU LE  
SUPPORT ADÉQUATS POUR PERMETTRE DE TIRER  
L’APPAREIL EN MONTANT OU EN DESCENDANT DES  
MARCHES OU UN ESCALIER. L’APPAREIL DOIT  
ÊTRE SOULEVÉ OU POUSSÉ SUR UNE RAMPE. NE  
PAS SOULEVER L’APPAREIL PAR LE MONTAGE DU  
COLLECTEUR EN RAISON DES DOMMAGES QU’IL  
POURRAIT AINSI SUBIR.  
SCHÉMA 3  
SCHÉMA 4  
Installation de la poignée  
1. Insérez l’extrémité ouverte de la poignée sous le chevalet de  
raccordement (schéma 1). Avant de fixer la poignée, vous devrez  
peut-être tirer sur les extrémités ouvertes de la poignée pour les  
écarter afin qu’elles puissent bien s’ajuster contre le côté du  
chevalet de raccordement. En faisant face à l’extrémité ouverte du  
chevalet, placez la poignée vers les deux pattes repliées, à  
l’intérieur des parois du chevalet. Poussez lentementles extrémités  
ouvertes de la poignées sur les deux pattes en même temps  
(schéma 2). Continuez àpousser la poignée dans le chevalet jusqu’à  
ce que les orifices sur le côté du chevalet et de la poignée soient  
alignés.  
2. Passez l’extrémitédroite de chaque bride de retenue.àtravers l’orifice  
du chevalet et des deux orifices de la poignée (schéma 3).  
3. Faites pivoter chaque bride de retenue dans le sens des aiguilles  
d’une montre et appuyez jusqu’à ce qu’elles fassent entendre un  
déclic et soient bien en place par-dessus les montants de la poignée  
(schéma 4).  
8 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROCÉDÉS DE RODAGE  
Vérifiez la fiche et le cordon de l’appareil avant chaque utilisa-  
tion. Ne les utilisez pas s’il y a des indices de dommages.  
Emplacement du compresseur d’air  
Faites fonctionner le compresseur d’air dans un endroit propre,  
sec et bien ventilé. Les lames du ventilateur à volant doivent être  
maintenues libres de toutes obstructions qui pourraient nuire  
au débit d’air qui passe par le filtre d’admission. Le carter et la  
tête de la pompe sont munis de lamelles permettant de fournir  
un refroidissement adéquat.  
UNE MAUVAISE MISE À LA MASSE POURRAIT  
OCCASIONNER DES CHOCSÉLECTRIQUES.  
Ne modifiez pas la fiche qui est fournie. Si elle ne convient pas  
à la prise disponible, une prise adéquate doit être installée par  
un électricien qualifié.  
Si le taux d’humidité dans la pièce est élevé, un filtre à air peut  
être installé sur l’adaptateur du tube de sortie d’air pour éliminer  
l’excès d’humidité. Suivez attentivement les instructions sur  
l’emballage du filtre pour en assurer l’installation adéquate. Il  
doit être installé aussi près que possible de l’accessoire. Ne pas  
placer le compresseur d’air là où il y a une chaleur intense.  
Lors de la réparation ou du remplacement du cordon ou de la  
fiche, le fil de terre doit être gardé séparément des fils porteurs  
d’électricité. Ne branchez jamais le fil de terre à une fiche avec  
lame de contact plate. Le fil de terre est recouvert d’une gaine  
isolante dont la surface externe est verte - avec ou sans rayures  
jaunes.  
Pour placer le compresseur à l’extérieur, assurez-vous qu’il y a  
un espace libre de 12 po (30,5 cm) au moins de chaque côté du  
compresseur. Une circulation d’air frais est nécessaire pour as-  
surer un refroidissement approprié. TENIR LE COMPRESSEUR  
À L’ABRI DE LA PLUIE.  
Si vous ne saisissez pas parfaitement ces directives sur la mise  
à la terre , ou en cas de doute sur la façon dont le compresseur  
est mis à la terre, faites vérifier l’installation par un électricien  
qualifié.  
Lubrificationethuile  
Les compresseurs sont expédiés sans huile. Ne  
tentez pas de faire fonctionner ce compresseur  
sans avoir versé de l’huile dans le carter. L’utilisa-  
tion du compresseur sans y avoir versé de l’huile,  
même pour une courte période, ou l’utilisation  
sans avoir rodé le compresseur de façon appro-  
priée, risque de causer des dommages graves. Il  
faut absolument suivre la procédure de mise en  
marche initiale.  
Modèles de 120 volts  
Modèles de 240 volts  
Filblanc  
Mise àla terre  
Mise àla terre  
FICHEDE20AMP  
PRISE  
PRISE  
FICHEDE15AMP  
PRISEAVEC  
Placez l’appareil sur une surface à niveau. Retirez le bouchon de  
remplissage d’huile et versez de l’huile spéciale pour compres-  
seurs, telle que l’huile Sears 9-16426 ou l’huile moteur SAE 20-  
20W SF, jusqu’à ce que le niveau atteigne la surface supérieure  
de l’orifice de remplissage. [Le niveau d’huile ne doit jamais être  
inférieur à 3/8 po (6 filets) de la surface supérieure]. Lorsque  
vous versez de l’huile dans le carter, l’huile s’écoule très lente-  
ment. Si vous ajoutez l’huile trop rapidement, elle débordera, ce  
qui vous fera penser que le carter est plein. La capacité d’huile  
du carter est de 16 onces liquides (473 ml). Utilisez de l’huile  
SAE 10W en hiver. L’huile à viscosité multiple 10W30 laissera  
des dépôts de charbon sur les composantes critiques, ce qui  
diminuera le rendement et la vie utile du compresseur. Replacez  
le bouchon de remplissage d’huile.  
MISE A LA  
TERRE  
POINTE  
MISEÀ  
LA TERRE  
POINTEDE  
MISEÀ  
LA TERRE  
Protection de la tension et du circuit  
Voyez les exigences de tension et de protection du circuit de  
votre compresseur sur la Liste des pièces. N’utilisez qu’un fusi-  
ble ou qu’un disjoncteur ayant les mêmes valeurs nominales  
que le circuit de dérivation sur lequel fonctionne le compresseur.  
Si le compresseur est branché sur un circuit protégé par des  
fusibles, n’utilisez que des fusibles à retardement à élément  
double tel qu’indiqué dans le Livret sur les pièces.  
REMARQUE :  
Purger et remplir le carter de la pompe du  
compresseur après les premières 100 heures  
d’utilisation.  
Certains compresseurs d’air peuvent être convertis de  
120 V à 240 V. Pour convertir un compresseur à 240 V,  
le cordon d’alimentation de 120 V muni d’une fiche à  
trois lames qui est fourni doit être remplacé par un  
cordon d’alimentation de 240 V avec une fiche à trois  
lames que vous trouverez au Sears Centre de service  
sous garantie autorisé.  
DirectivesMiseàlamasse  
RISQUE DE CHOC ÉLECTRIQUE ! En cas de court  
circuit, la mise à la terre réduit les risque de choc en  
fournissant un fil de fuite pour le courant électrique.  
Le compresseur d’air doit être adéquatement mise à  
la terre.  
Certains modèles ont un moteur à double tension, de 120 et de  
240 V. Le câblage est pour le 120 volt mais il peut être converti à  
240 volts. Les instructions pour la conversion au 240 V se  
trouvent imprimées sur l’étiquette fixée sur le côté du moteur.  
Ce compresseur d’air est muni d’un cordon ayant un fil de mise  
à la terre avec une fiche appropriée de mise à la terre. La fiche  
doit être utilisée avec une prise de courant de terre installée  
selon les normes et codes locaux. La prise doit avoir la même  
configuration que la fiche. Voir schéma. N’UTILISEZ PAS  
D’ADAPTATEUR.  
9 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Procédures de mise en route  
Certains modèles de compresseur d’air peuvent  
fonctionner sur un circuit de 15 ampères pourvu que:  
1. L’alimentation de la tension au circuit est normale.  
2. Le circuit n’est pas utilisépour répondre àd’autres  
besoins électriques (éclairages, appareils  
ménagers, etc.)  
3. Les rallonges sont conformes aux spécifications  
indiquées dans ce guide.  
4. Le circuit est muni d’un disjoncteur ou d’un  
Il y a risque de graves dommages si les procédures de  
mise en route ne sont pas étroitement observées.  
Ces procédures sont requises  
1. Avant la mise en service du compresseur. (Avant que le boyau  
ne soit installé.)  
2. Lors du remplacement de la soupape de retenue  
3. Quand la pompe du compresseur est complètement  
remplacée.  
fusible à retardement de 15 ampères.  
a. Mettez le levier du manostat en position d’arrêt (OFF).  
b. Branchez le cordon d’alimentation du compresseur dans  
la prise du circuit de dérivation approprié.  
c. Tournez le régulateur dans le sens des aiguilles d’une montre  
en l’ouvrant complètement (ou ouvrez la soupape d’arrêt)  
pour prévenir l’accumulation de pression d’air dans le  
réservoir.  
d. Mettez le levier du manostat en position de mise en marche/  
auto (ON/AUTO). Le compresseur se met alors en marche.  
e. Faites fonctionner le compresseur pendant 30 minutes.  
Assurez-vous que le régulateur (ou soupape d’arrêt) soit  
ouvert et qu’il n’y a aucune accumulation de pression dans  
le réservoir.  
f. Après 30 minutes, fermez le régulateur en tournant le bou-  
ton dans le sens contraire des aiguilles d’une montre (ou  
fermez la soupape d’arrêt en tournant dans le sens des  
aiguilles d’une montre). Le réservoir se remplit jusqu’à la  
pression de coupe-circuit puis le moteur s’arrête. Le  
compresseur est prêt à être utilisé.  
Rallonges  
Utilisez une conduite d’air supplémentaire au lieu d’une rallonge  
pour éviter une baisse de tension, une perte de puissance et une  
surchauffe du moteur.  
Si une rallonge devait être utilisée, assurez-vous :  
• d’utiliser une rallonge trifilaire qui comprend une fiche à trois  
lames avec mise à la terre et une prise à trois fentes qui accepte  
la fiche de la rallonge.  
• qu’elle est en bon état.  
• qu’elle n’excède pas 50 pi.  
• qu’elle est d’un calibre minimal de 12 AWG (jauge américaine  
des fils). (La grosseur du fil augmente comme le numéro  
de jauge diminue). 10 AWG et 8 AWG peuvent également  
être utilisés. N’UTILISEZ PAS UN CALIBRE DE 14 OU DE  
16 AWG.  
Tuyauterie  
Les tuyaux de plastique ou de CPV (PVC) ne sont  
pas conçus pour une utilisation avec de l’air  
comprimé. Peu importe la tension nominale  
indiquée, un tuyau de plastique peut éclater sous  
la pression de l’air comprimé. N’utiliser qu’un  
tuyau de métal pour les lignes de distribution.  
Si une conduite de tuyaux est nécessaire, utilisez un tuyau de  
même diamètre que la sortie d’air du réservoir. Une tuyauterie  
qui est trop petite restreint le débit d’air. Si la tuyauterie est de  
plus de 100 pi (30,5 m), utilisez un tuyau de une grosseur de  
diamètre de plus. Enfouissez les conduites souterraines sous la  
ligne de gel et évitez les poches d’air où la condensation peut  
s’accumuler et geler. Appliquez de la pression avant d’enfouir  
complètement les tuyaux pour vous assurer qu’il n’y a aucune  
fuite aux raccords.  
Branchez la conduite à l’ouverture de la sortie d’air de 3/8 po  
NPT qui est située à l’extrémité du réservoir.  
Régulateurs et contrôles supplémentaires  
Étant donné que la pression dans le réservoir d’air est  
généralement plus élevée que la pression nécessaire, un  
régulateur distinct est habituellement employé pour contrôler la  
pression d’air avant tout dispositif pneumatique.  
Un condensateur d’air distinct qui combine la fonction de  
régularisation d’air et d’enlèvement de la saleté et de l’humidité  
devrait être utilisé au besoin.  
10 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROCÉDURES OPÉRATIONNELLES  
1. Avant de brancher le boyau d’air ou un accessoire,  
Une fois les travaux terminés:  
s’assurer que le levier AUTO/O est à la position “O”  
et que le détendeur est fermé.  
2. S'assurez que rien ne bloque le carter de la courroie, les  
évents ou l'admission du filtre á air.  
12. Mettre le levier à la position d’arrêt “O”  
13. Tourner le détendeur dans le sens contraire des  
aiguilles d’une montre et régler la pression de sortie  
à zéro.  
3. Tirez sur l’anneau de toutes les soupapes de sûreté pour  
vous assurer que les soupapes se déplacent librement et  
sansproblèmes.  
14. Débrancher l’outil ou l’accessoire.  
15. Ouvrir le détendeur et évacuer l’air du réservoir.  
Fermer le détendeur quand la pression atteint  
20 psi  
4. Vérifiez le niveau d’huile ; ajoutez de l’huile au besoin  
5. Nettoyez ou appliquez un jet d’air sur les lamelles ou toutes 16. Vidanger l’eau de condensation du réservoir.  
autres pièces du compresseur où s’accumulent la poussière  
et la saleté. Le compresseur obtient ainsi un meilleur  
refroidissement et donne une plus longue durée de vie utile.  
La vapeur d’eau contenue dans l’air comprimé se  
6. Avant de fixer un boyau d’air ou un accessoire, assurez-  
condense dans le réservoir Si cette eau n’est pas  
vous que le levier du manostat est en position d’arrêt (OFF).  
vidangée, elle occasionnera la corrosion et  
Fermez la sortie du régulateur d’air en le tournant dans le  
l’affaiblissement du réservoir, pouvant provoquer sa  
sens contraire des aiguilles d’une montre.  
rupture.  
7. Fixez le boyau et l’accessoire.  
Note  
Si la vanne de vidange est bouchée, dégager toute la  
pression du réservoir. Démonter la vanne, la  
nettoyer et la remonter.  
Une pression d’air excessive est un danger potentiel  
pouvant provoquer l’éclatement d’un outil.Suivre  
scrupuleusement les étapes 3 et 5 suivantes chaque fois  
qu’on utilise le  
17. Unefoisleréservoirvidangé,fermerlavannedevidange.Le  
compresseur.  
compresseur est à présent prêt pour l’entreposage.  
L’air comprimé peut contenir de l’eau de condensation. Ne  
pas vaporiser avec de l’air comprimé non filtré, des objets  
pouvant être détériorés. Certains outils pneumatiques  
exigent de l’air comprimé filtré. Lire les instructions se  
rapportant à l’outil.  
8. Vérifier la pression maximum permise par le fabricant de  
l’outil. La pression à la sortie du détendeur ne doit jamais  
dépassercemaximum.  
9. Mettre le levier à la position “Auto”. Le réservoir se remplit  
d’airetlemoteurs’arrêtequandlapressiondansleréservoir  
atteint le point d’arrêt du pressostat.  
10. Ouvrir le détendeur en le tournant dans le sens des  
aiguilles d’une montre. Régler le détendeur à la pression de  
sortie adéquate. Le compresseur est à présent prêt à  
l’utilisation.  
11. N’utiliser le compresseur d'air que dans des locaux bien  
ventilés et dépourvus de vapeurs d’essence ou de solvant.  
Ne pas faire fonctionner le compresseur près des locaux de  
vaporisation.  
11 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENTRETIEN  
L'appareil fonctionne et s’arrête automatiquement quand il est branché. Quand on entreprend des travaux  
d’entretien, on s’expose à une tension électrique, à de l’air comprimé et à des pièces en mouvement et de  
graves blessures peuvent en résulter. Pour éviter tout danger, toujours débrancher le compresseur de  
l’alimentation de courant et vider l’air du réservoir avant de procéder aux travaux d’entretien.  
Tous les travaux autres que ceux décrits dans ce manuel ne doivent être effectués que par un technicien qualifié.  
Huile - Vérification et remplacement  
Horaire d’entretien de routine  
Quotidien :  
1. Vérifiez le nieau d’huile. Ajoutez au besoin.  
2. Purgez l’eau du réservoir d’air et toute humidité sur les  
séparateurs et condensateurs.  
Un trop-plein d’huile provoque un bris prématuré  
du compresseur. Éviter de trop remplir.  
3. Vérifiez s’il y a une vibration ou des bruits inhabituels.  
4. Vérifiez manuellement toutes les soupapes de sûreté pour  
vous assurer qu’elles fonctionnent adéquatement.  
5. Vérifiez s’il y a des fuites d’huile et le cas échéant, faites les  
réparations nécessaires.  
6. Vérifiez le filtre à air et remplacez-le au besoin.  
Toutes les 40 heures de service :  
1. Nettoyez et vérifiez le filtre d’admission d’air ; remplacez-le  
au besoin.  
Vérifiez quotidiennement le nivau d’huile dans le carter –  
Enlevez-le bouchon d’huile. Le niveau d’huile doit être au même  
niveau que le haut de l’orifice de remplissage et ne doit en aucun  
cas être inférieur à 3/8 po (9,5 mm) du haut de l’orifice (6 filets).  
Nous recommandons de changer l’huile toutes les 100 heures  
de service. Pour vidanger l’huile, enlevez le bouchon du purgeur  
d’huile et recueillez l’huile dans un bac approprié. Assurez-vous  
de remettre le bouchon et de bien le fixer avant d’ajouter de  
l’huile. Utilisez de l’huile à compresseur telle que l’huile Sears 9-  
16426 ou l’huile moteur SAE 20-20W SF, jusqu’à ce que le  
niveau atteigne la surface supérieure de l’orifice de remplissage.  
Le carter d’huile a une capacité de 16 onces liquides (473,2 mL).  
2. Vérifiez l’état de la courroie d’entraînement ; remplacez-la au  
besoin.  
Toutes les 100 heures de service :  
1. Purgez et remplir le carter du compresseur avec 16 onces  
liquides (473,2 mL) d’une huile à compresseur neuve telle  
que l’huile Sears 9-16426 ou l’huile moteur SAE 20-20W SF,  
jusqu’à ce que le niveau atteigne la surface supérieure de  
l’orifice de remplissage.  
2. Augmentez la fréquence des changements d’huile dans des  
conditions extrêmes d’humidité ou dans des conditions dures.  
Toutes les 160 heures de service :  
1. Vérifiez la tension de la courroie d’entraînement ; réglez-la au  
besoin. (Voir les INSTRUCTIONS SUR LE SERVICE dans ce  
guide).  
2. Vérifiez s’il y a des fuites dans les conduites d’air et les  
raccords. Corrigez la situation au besoin.  
3. Vérifiez l’alignement de la poulie au volant. Au besoin, alignez  
à moins de 1/32 po sur la ligne du centre.  
Tous les ans ou en cas d’un problème éventuel :  
Vérifiez l’état des soupapes d’admission et d’échappement de  
la pompe du compresseur. Remplacez-les en cas de dommages  
ou d’usure.  
Soupape de retenue - Vérification et remplacement  
Enlevez et vérifiez la soupape de retenue au moins une fois l’an  
ou plus souvent si le compresseur est énormément utilisé.  
L’humidité et autres corps étrangers dans l’air comprimé chaud  
provoque l’accumulation de résidus ressemblant au carbone sur  
les pièces mobiles. La soupape doit être remplacée si elle est  
souillée d’une épaisse accumulation de carbone. Effectuez les  
procédures suivantes pour vérifier, nettoyer ou remplacer la  
soupape de retenue.  
1. Éteignez le compresseur. Libérez toute pression d’air contenue  
dans le réservoir.  
2. Desserrez les écrous au haut et au bas du tube de sortie et  
retirez le tube.  
3. Dévissez la soupape de retenue (tournez dans le sens contraire  
des aiguilles d’une montre) à l’aide d’une clé à douille de 7/8  
po (2,22 cm).  
4. Vérifiez si le clapet de la soupape se déplace librement et si le  
ressort retient le clapet à la verticale en position fermée. La  
soupape de retenue peut être nettoyée avec un solvant.  
5. Appliquez un scellant sur les filets de la soupape de retenue.  
Réinstallez la soupape de retenue (tournez dans le sens des  
aiguilles d’une montre). NE SERREZ PAS TROP.  
6. Remettez le tube de sortie et serrez les écrous au haut et au  
bas du tube.  
Filtre à air – Vérification et remplacement  
Garder le filtre à air propre en tout temps. Ne pas  
faire fonctionner le compresseur sans le filtre à air.  
Soupape de sûreté - Inspection  
Un filtre à air souillé ne permet pas au compresseur de  
fonctionner à pleine capacité. Avant d’utiliser le compresseur,  
vérifiez le filtre à air pour vous assurer qu’il est propre.  
Si la soupape de sûreté ne fonctionne pas  
correctement, une pression excessive peut  
s’accumuler à l’intérieur du réservoir, causant sa  
rupture ou son explosion. Avant de mettre en  
marche, tirer sur l’anneau de la soupape de sûreté  
afin de s’assurer qu’elle fonctionne correctement.  
Si la soupape est bloquée ou fonctionne  
S’il est souillé, remplacez-le par un filtre à air neuf. Sur certains  
modèles, le filtre peut être enlevé à l’aide d’une paire de pinces à  
bec effilé ou d’un tournevis. Tirez sur le filtre usé. Poussez le  
filtre neuf en place. Les autres modèles exigent l’enlèvement du  
carter de la courroie ou du logement du filtre.  
difficilement, la remplacer par une soupape neuve  
ayant les mêmes caractéristiques.  
12 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
redémarrer, appuyez sur le bouton rouge de remise à zéro qui  
est situé à l’extrémité du moteur et tournez le bouton de mise en  
marche/auto – arrêt (ON/AUTO-OFF) en position de marche (ON).  
Courroie – Remplacement  
RISQUE DE GRAVES BLESSURES OU DE  
DOMMAGES PAR EXPOSITION DE VÊTEMENTS  
AMPLES, PARTIES DU CORPS OU AUTRES ARTI-  
CLES AUX PIÈCES MOBILES. NE JAMAIS FAIRE  
FONCTIONNER L’APPAREIL SANS LE CARTER DE  
COURROIE. LE CARTER DE COURROIE NE DEVRAIT  
ÊTRE ENLEVÉ QUE LORSQUE LE COMPRESSEUR  
EST DÉBRANCHÉ.  
REMARQUE  
Si le déclencheur de surcharge coupe le moteur  
fréquemment, vérifiez s’il y a un problème de tension.  
Une tension trop faible peut être la cause du problème  
lorsque :  
1. Le moteur n’atteint pas sa pleine puissance ou son  
plein régime (vitesse).  
2. Les fusibles sautent lorsque le moteur démarre.  
3. Les lumières s’atténuent lorsque le moteur est mis  
en marche et demeurent faibles lorsque l’appareil  
fonctionne.  
Carter de la courroie – Enlèvement et installation  
(Voir le Livret des pièces au besoin.)  
1. Placez le levier de mise en marche/auto-arrêt (ON/AUTO-  
OFF) en position d’arrêt (OFF). Débranchee le compresseur.  
Purgez complètement l’air contenue dans le réservoir.  
2. Sur les carters de courroie monobloc, retirez les deux vis du  
carter situées au bas du devant de l’appareil.  
3. Sur les carters de courroie comprenant deux parties, enlevez  
l’avant du carter en le libérant des fixations à pression. Insérez  
un tournevis à lame plate à chaque fixation à pression et  
dégagez le carter de la courroie.  
Poulie et volant – Alignement  
Le volant du compresseur doit être aligné dans les rainures de la  
poulie du moteur à moins de 1/32 po (0,794 mm) pour assurer  
l’alignement de la courroie dans les rainures. Pour vérifier  
l’alignement, débranchez l’appareil et enlevez le carter de  
courroie. Placez un objet rectiligne droit (telle qu’une règle)  
contre l’extérieur du volant et mesurez la distance du volant à la  
rainure la plus proche. Il y a alignement lorsque l’autre extrémité  
de la bordure droite de l’objet rectiligne est à moins de 1/32 po  
de la valeur mesurée aux rainures de la poulie.  
.
Remplacement de la courroie  
1. Débranchez le compresseur.  
2. Enlevez le carter de la courroie (monobloc), ou le devant du  
carter (en deux parties), tel qu’indiqué plus haut.  
Entretien des soupapes d’admission et  
d’échappement  
Les surfaces des soupapes d’admission et d’échappement ainsi  
que des sièges des soupapes et de la tête du cylindre accumulent,  
avec le temps, un résidu ressemblant au carbone. Cette matière  
réduit l’efficacité du compresseur. Ces pièces doivent être  
vérifiées chaque fois qu’un problème peut survenir et elles  
doivent être nettoyées ou remplacées par des pièces neuves.Voir  
le Livret sur les pièces au besoin. Effectuez les étapes suivantes  
pour vérifier les pièces :  
1. Débranchez l’appareil et purgez complètement la pression  
d’air dans le réservoir.  
2. Débranchez le détendeur de pression et tubes de sortie du  
compresseur d’air.  
REMARQUE  
Desserrez l’écrou-papillon de la plaque de soutien. Le  
moteur peut être incliné pour faciliter l’enlèvement ou  
l’installation de la courroie.  
3. Enlevez la courroie et remplacez-la.  
REMARQUE  
La courroie doit être centrée sur les rainures du volant  
et de la poulie du moteur.  
Réglage de tension de la courroie  
Réglez la tension de la courroie en serrant l’écrou-papillon  
jusqu’à ce qu’il touche à la rondelle, ajoutez ensuite un tour  
additionnel.  
3. Enlevez les pièces de quincaillerie qui retiennent la tête du  
cylindre et retirez la tête du cylindre et le siège de la soupape.  
Manostat – Remplacement  
DE NOMBREUX SOLVANTS SONT HAUTEMENT  
INFLAMMABLES ET CONSTITUENT UN RISQUE  
POUR LA SANTÉ PAR INHALATION. RESPECTER  
TOUJOURS LES MESURES DE SÉCURITÉ ET LES  
MISES EN GARDE DU FABRICANT DU SOLVANT.  
UNE SURCHARGE DE PRESSION AU-DELÀ DES  
LIMITES PEUT CAUSER LA RUPTURE OU  
L’EXPLOSION  
FONCTIONNEMENT DU MANOSTAT EST LIÉ À LA  
PUISSANCE DU MOTEUR (HP), AUX  
DU  
RÉSERVOIR.  
LE  
4. Éliminez les dépots de carbone dans la cavité de la tête du  
cylindre et sur le siège des soupapes en utilisant un diluant  
de vernis ou autre solvant approprié.  
5. Nettoyez les soupapes d’admission et d’échappement  
avec le diluant de vernis ou autre solvant approprié.  
Vérifiez les soupapes ; remplacez-les au besoin.  
SPÉCIFICATIONS DU RÉSERVOIR ET AU RÉGLAGE  
DE LA SOUPAPE DE SÛRETÉ. NE PAS TENTER DE  
RÉGLER, D’ENLEVER NI DE CONTOURNER LE  
MANOSTAT NI DE CHANGER OU DE MODIFIER LES  
DISPOSITIFS DE CONTRÔLES DE PRESSION. SI UN  
REMPLACEMENT EST NÉCESSAIRE, UN MANOSTAT  
DE MÊMES SPÉCIFICATIONS DOIT ÊTRE UTILISÉ.  
COMMUNIQUEZ AVEC LE CENTRE DE SEARS SERV-  
ICE AUTORISÉ POUR LE REMPLACEMENT.  
REMARQUE  
N’utiliser aucun ciment pour garnitures sur la sur-  
face des garnitures en raison du risque d’obstruction  
des cavités des soupapes du compresseur et du débit  
d’air.  
Déclencheur de surcharge thermique  
6. Réinstallez le siège de soupape et les garnitures.  
7. Installez la tête du cylindre. Serrez bien les vis de montage et  
les vis sans tête puis appliquez une pression de 25 à 30 lb-  
pi en commençant par le centre et en allant vers l’extérieur.  
8. Rebranchez les détendeur de pression et tubes de sortie à la  
pompe du compresseur.  
pour la protection du moteur – Remise à zéro  
Le moteur est muni d’un protecteur de surcharge thermique  
manuel. Si le moteur surchauffe pour une raison ou une autre, le  
déclencheur de surcharge coupe le moteur. Le moteur doit refroidir  
avant d’être remis en marche. Éteignez l’appareil. Pour le faire  
13 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Entreposage du Compresseur  
1. Consultez le chapitre portant sur l’Entretien dans les pages  
précédentes et effectuez les tâches d’entretien au besoin.  
Purgez l’eau du réservoir d’air.  
2. Réglez le bouton de mise en marche/auto-arrêt (ON/AUTO-  
OFF) en position d’arrêt (OFF) et débranchez l’appareil.  
3. Retirez tout accessoire ou outil pneumatique.  
4. Protégez le cordon électrique et le boyau d’air contre tout  
dommage (pour éviter qu’un passant marche ou trébuche sur  
le cordon). Enroulez-les lâchement autour de la poignée de  
l’appareil.  
5. Entreposez le compresseur dans un endroit frais et sec.  
GUIDE DE DÉ PANNAGE  
Durant les réparations et les travaux d’entretien, on est souvent en contact avec les parties électriques,  
mécaniques ou pneumatiques du compresseur et des accidents peuvent survenir. Il est donc important de  
débrancher le courant au compresseur et de libérer la pression d’air du réservoir avant d’entreprendre des  
travaux d’entretien ou de réparation.  
CAUSE  
PROBLÈME  
SOLUTION  
Mettrelelevierdupressostatàlapositiond’arrêt“O”.  
Si le compresseur ne s’arrête pas, débrancher  
l’alimentationélectriqueets’adresseràuncentrede  
service Sears pour remplacer le pressostat.  
Pression excessive dans le  
réservoir - La soupape de  
sûretés’ouvre.  
Le pressostat n’arrête pas le moteur  
quand le compresseur atteint le point  
de consigne d’arrêt.  
S’adresseràuncentredeserviceSearspourvérifier,  
régler ou remplacer le pressostat.  
Le point de consigne d’arrêt du  
pressostat est trop élevé.  
Serrerlesraccordslàoùl’airfuit.Vérifiercesraccords  
avec une solution d’eau savonneuse.  
Fuites d’air du boyau ou des  
raccords  
Les raccords ne sont pas  
suffisamment serrés.  
NE PAS SERRER OUTRE MESURE.  
S’adresseràuncentredeserviceSearspourremplacer  
le pressostat et le détendeur de pression.  
Fuites d’air au détendeur de  
pression du pressostat  
Détendeur de pression défectueux.  
Vérifier si la tige qui se trouve au bas du détendeur  
de pression, est coincée. Si elle ne se déplace pas  
facilement, retournez le compresseur au Centre de  
service pour faire remplacer le pressostat.  
Un clapet défecteux laisse fuir l’air par le détendeur  
quand le moteur est à l’arrêt et que le réservoir est  
souspression.Démonterleclapet.Lenettoyeroule  
remplacer. NE PAS SERRER OUTRE MESURE.  
Clapet de retenue défectueux ou sale.  
Réservoirdéfectueux.  
Leréservoird’airdoitêtreremplacé. Nepasréparer  
unréservoir.S’adresseràuncentredeserviceSears.  
Fuites d’air dans le réservoir  
d’air comprimé ou dans ses  
soudures  
Nepaspercer,soudernimodifierleréservoir  
carcelarisqueraitdel’affaibliretprovoquer  
saruptureousonexplosion.  
Serrer les boulons à 7-10 pi.lb. S’il y a encore fuite,  
remplacer le joint.  
L’air fuit entre la tête de  
culasse et la culasse  
Boulons lâches ou joint de culasse  
défectueux.  
Si la chute est excessive, régler le détendeur.  
Le manomètre du détendeur  
indique une chute de pression  
dès qu’on branche un outil  
Une “petite” chute de pression est  
normale.  
Note:  
Régler le détendeur pendant que l’outil est en  
utilisation.  
Fairefonctionnerlasoupapedesûretémanuellement  
en tirant sur la bague. Si la fuite se maintient,  
remplacerlasoupapedesûreté.  
Fuites d’air à la soupape de  
sûreté  
Soupape de sûreté défectueuse.  
14 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUSE  
PROBLÈME  
SOLUTION  
Bruit de cognement  
Clapet de retenue défectueux.  
Poulie relâchée.  
Démonter, nettoyerouremplacer.  
Resserrez les vis de réglage de la poulie  
Ajoutez de l'huile. Maintenez le niveau prescrit.  
Resserrez les vis à 15/20 lb-pi.  
Niveau d’huile trop faible.  
Volant relâché.  
Vis de montage du compresseur  
Vérifiez les vis. Resserrez au besoin ( 15/20 lb-pi).  
relâchées.  
Courroie relâchée.  
Serrez l’écrou-papillon jusqu’à ce qu’il touche à la  
rondelle, puis faites un tour additionnel.  
Réglez la tension de la courroie ( Voir  
“Remplacement de la courroie”).  
Courroie trop serrée.  
Enlevez la tête et le siège de la soupape. Nettoyez  
le siège de la soupape et le haut du piston (Assurez-  
vous que le carbone ne tombe pas dans le cylindre).  
Réassemblez en utilisant des nouvelles garnitures  
et vis de tension à une tension de 25 à 30 lb-pi.  
Accumulation de carbone.  
Le compresseur ne fournit pas  
suffisamment d’air pour faire  
fonctionner les accessoires.  
Utilisation excessive et prolongée de Réduisez l’utilisation de la quantité d’air.  
l’air.  
Le compresseur n’est pas assez gros Vérifiez les exigences d’air des accessoires. Si elles  
pour les exigences d’air.  
sont plus élevées que le CFM (pi3/min ), le SCFM  
(pi3/min standard) ou que la pression fournie par  
votre compresseur, vous avez besoin d’un  
compresseur plus gros.  
Filtre d’admission d’air obstrué.  
Nettoyez ou remplacez le filtre d’admission d’air.  
Ne faites pas fonctionner le compresseur dans l’aire  
ou la cabine de vaporisation de peinture.  
Courroie relâchée.  
Réglez la tension de la courroie.  
Vérifiez et remplacez au besoin.  
Enlevez et nettoyez ou remplacez  
Resserrez les raccords.  
Boyau perforé.  
Soupape de retenue obstruée.  
Fuites d’air.  
Usure excessive de la courroie.  
Courroie relâchée ou trop serrée.  
Réglez la tension selon les instructions (Voir la sec-  
tion “Réglage ou remplacement de la courroie” dans  
ce guide).  
Poulie relâchée.  
Vérifiez si l’alésage ou les rainures de la poulie sont  
usés. Vérifiez aussi si l’arbre du moteur est courbé.  
Remplacez les pièces au besoin.  
Poulie mal alignée.  
La poulie et volant du moteur doivent être alignés à  
moins de 1/32 po. (Voir la section “Poulie et Volant  
– Alignement” dans ce guide).  
Crissements  
Courroie relâchée.  
Réglez la tension de la courroie. (Voir la  
section“Remplacement de la courroie” dans ce  
guide).  
Aucune huile dans le compresseur.  
Ajoutez de l’huile jusqu’au haut de l’orifice de  
remplissage situé à la base de l’appareil.  
15 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUSE  
PROBLÈME  
SOLUTION  
Le moteur ne fonctionne pas  
Tuyau d’air troué.  
Clapet de retenue bloqué  
Fuites d’air  
Démonter, nettoyerouremplacer.  
Serrerlesraccords.  
Lecompresseurdémarreautomatiquementaussitôt  
que la pression du réservoir baisse au niveau du  
point déclenchement du pressostat.  
La pression dans le réservoir est  
supérieureaupointdedéclenchement  
du pressostat.  
1. Vérifier fusible ou disjoncteur. Remplacer ou  
réarmer. Ne pas utiliser un fusible ou un  
disjoncteur de calibre supérieur à la capacité  
du circuit  
Le fusible a sauté ou le disjoncteur a  
déclenché.  
2. Vérifier le type de fusible. N’utiliser que des  
fusibles à action différée  
3. Vérifier la tension d’alimentation. Vérifier le  
calibre de la rallonge.  
4. Ne pas faire fonctionner les autres appareils  
s’alimentant sur le même circuit ou brancher  
le compresseur sur un circuit indépendant.  
5. Vérifier si des connexions sont lâches.  
Laisser refroidir le moteur. Le dispositif de protec-  
tion mettra en marche le moteur aussitôt celui-ci  
refroidi.  
Le dispositif thermique de protection  
du moteur a déclenché.  
S’adresser à un Centre de Service Sears pour  
vérification ou remplacement.  
Condensateur ou moteur défectueux  
S’adresseràuncentredeserviceSears.Nepasfaire  
fonctionner le moteur dans les locaux de peinture.  
Voir la mise en garde concernant les vapeurs  
inflammables.  
Des vapeurs de peinture se sont  
infiltrées dans le moteur.  
Démonter, nettoyer ou remplacer le clapet.  
Clapet de retenue bloqué en position  
ouvertecréantdelapressionsurlatête  
ducompresseur.  
Purger la ligne en mettant le levier du pressostat à  
la position “O”; si le détendeur ne s’ouvre pas, le  
remplacer.  
Ledétendeurdepressiondupressostat  
n’apas dégagé lapressiondelaculasse  
ducompresseur.  
Bouton du régulateur – fuite d’air  
continue. Le régulateur ne coupe  
pas à la sortie d’air.  
Pièces internes du régulateur souillées ou  
endommagées.  
Nettoyez ou remplacez le régulateur ou ses pièces  
internes.  
Possibilité d’une défectuosité de la Faites fonctionner la soupape de sûreté  
Fuite d’air à la soupape de sûreté.  
soupape de sûreté.  
manuellement en tirant sur l’anneau. Si la soupape  
accuse toujours une fuite, remplacez-la.  
16 — FR  
D21245  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MANUEL D’INSTRUCTIONS DU  
COMPRESSEUR D’AIR  
LUBRIFICATION PERMANENTE  
MONTÉ SUR RÉSERVOIR  
CRAFTSMAN  
Le numéro de modèle du compresseur d’air Sears figure sur  
l’étiquette d’entretien sur le dessus du boîtier ou sur  
l’étiquette  
N° DE MODÈLE  
de code à barres à l’arrière du réservoir d’air.  
ENTRETIEN  
ENTRETIEN ET PIÈCES DE RECHANGE  
COMPOSEZ 1-800-665-4455*  
Conservez ce numéro à portée de la main au cas où  
vousauriez besoin d’une visite d’entretien ou de  
pièces de rechange.  
Lorsque vous commandez des pièces de rechange,  
indiquez le nom, la marque et le n° de modèle du  
produit ainsi que le nom et le numéro de la pièce  
que vous désirez commander.  
*Si vous appelez un centre d’entretien local, composez un  
des numéros suivants :  
Regina - 566-5124  
Toronto - 744-4900  
Kitchener - 894-7590  
Montréal - 333-5740  
Halifax - 454-2444  
Ottawa - 738-4440  
Vancouver - 420-8211  
POUR COMMANDER DES PIÈCES DE RECHANGE, IL FAUT  
TOUJOURS INDIQUER LES RENSEIGNEMENTS SUIVANTS :  
POUR COMMANDER  
DES PIÈCES DE  
RECHANGE  
• NUMÉRO DE LA PIÈCE  
• NUMÉRO DE MODÈLE  
•DESCRIPTIONDELAPIÈCE  
• NOM DE L’ARTICLE  
On peut commander toutes les pièces indiquées dans ce  
manuel à n’importe quel Centre d’entretien Sears et dans la  
plupart des magasins Sears.  
Si le magasin Sears auquel s’adresse le client n’a pas en stock  
les pièces désirées, la commande sera transmise par  
ordinateur à un centre de distribution de pièces de rechange  
Sears pour en accélérer le traitement et l’expédition.  
Vendu par Sears Canada, Inc., Toronto, Ont. M5B 2B8  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Conair Iron GS11DR User Manual
Cooper Lighting Landscape Lighting 1192 User Manual
Craftsman Trimmer 3587951 User Manual
Cub Cadet Lawn Mower LT1042 User Manual
Earthquake Sound Speaker EQ88 User Manual
Eclipse Fujitsu Ten Car Stereo System cd5425 User Manual
Estate Garage Door Opener E SC 1102 User Manual
Fellowes Paper Shredder FS 3 User Manual
Frigidaire Cooktop 318200633 User Manual
Gilson Mixer 59015C User Manual