N Tron Switch 708M12 User Manual

708M12  
Managed Industrial  
Ethernet Switch  
User Manual &  
Installation  
Guide  
(Revised 2010-11-15)  
Page 1 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(Revised 2010-11-15)  
Page 3 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
708M12 Industrial Ethernet Switch Installation Guide  
The N-TRON 708M12 Industrial Ethernet Switch offers outstanding performance and ease of use. It is  
ideally suited for connecting Ethernet enabled industrial and or security equipment and is a fully managed  
switch.  
PRODUCT FEATURES  
MANAGEMENT FEATURES  
• Full IEEE 802.3 Compliance  
SNMP v1, v2 and v3  
• Eight 10/100 BaseTX D Coded M12 Copper Ports  
• Extended Environmental Specifications  
IP65 Rated for protection against low pressure jets of  
water from any direction  
• Configuration backup via Optional Configuration Device (NTCD)  
• EtherNet/IP™ CIP Messaging  
IGMP Auto Configuration and Plug and Play Support  
• 802.1Q tag VLAN and Port VLAN  
IP66 Rated for protection against high pressure jets of  
water from any direction  
• 802.1p QoS, Port QoS, and DSCP  
Trunk with other N-Tron trunking capable switches over two ports  
IP67 Rated for protection against temporary immersion • Mirroring  
in water  
• N-RING™ (N-Tron proprietary Ring Management)  
• Autosensing 10/100BaseTX, Duplex, and MDIX  
• Offers Rapid Spanning Tree Protocol  
• Trunk with other N-Tron trunking capable switches  
over two ports  
• N-LINK™ (N-Tron proprietary Coupling Management)  
• 802.1d, 802.1w, 802.1D RSTP (Rapid Spanning Tree Protocol)  
• DHCP Client, Server, Option 82 relay, Option 61  
• Local Port IP Addressing  
• Store & Forward Technology  
Port SecurityMAC Address Based  
• Plug and Play IGMP Support  
802.1AB™-2005 Link Layer Discovery Protocol (LLDP)  
• Rugged Din-Rail Enclosure  
• Redundant Power Inputs (10-30 VDC)  
• Web Browser Management with detailed ring map and  
fault location charting.  
• Web Browsing and N-View Switch Monitoring  
(Revised 2010-11-15)  
Page 5 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
High Voltage Model Only  
708M12 Industrial Ethernet Switch Accessories  
Configuration Device  
Ideal for saving, or restoring switch configuration  
parameters quickly without the need for a computer or  
software. Straight M12 A-Coded 4-pin male connector.  
Includes connection status LED. One configuration device  
per switch is recommended.  
700-NTCD-M12  
Serial Interface Cable  
See section ―Serial Interface‖ for additional details.  
SERIAL-DB9-M12  
(Revised 2010-11-15)  
Page 6 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Copyright, © N-Tron Corp., 2008  
820 S. University Blvd., Suite 4E  
Mobile, AL 36609 USA  
All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-Tron  
Corp. is prohibited, except as allowed under copyright laws.  
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos  
or other designations mentioned herein are trademarks of their respective owners.  
The information contained in this document is subject to change without notice. N-Tron Corp. makes no  
warranty of any kind with regard to this material, including, but not limited to, the implied warranties of  
merchantability or fitness for a particular purpose. In no event shall N-Tron Corp. be liable for any  
incidental, special, indirect, or consequential damages whatsoever included but not limited to lost profits  
arising out of errors or omissions in this manual or the information contained herein.  
Warning  
Do not perform any services on the unit unless qualified to do so. Do not substitute unauthorized parts or  
make unauthorized modifications to the unit.  
Do not operate the unit with the top cover removed, as this could create a shock or fire hazard.  
Do not operate the equipment in the presence of flammable gasses or fumes. Operating electrical equipment  
in such an environment constitutes a definite safety hazard.  
Do not operate the equipment in a manner not specified by this manual.  
(Revised 2010-11-15)  
Page 7 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Warnings  
GENERAL SAFETY WARNINGS  
WARNING: If the equipment is used in the manner not specified by N-Tron Corp., the protection  
provided by the equipment may be impaired.  
Contact Information  
N-Tron Corp.  
820 South University Blvd.  
Suite 4E  
Mobile, AL 36609  
TEL: (251) 342-2164  
FAX: (251) 342-6353  
ENVIRONMENTAL SAFETY  
WARNING: Disconnect the power and allow to cool 5 minutes before touching.  
ELECTRICAL SAFETY  
WARNING: Disconnect the power cable before removing the top cover.  
WARNING: Do not operate the unit with the any cover removed.  
WARNING: Properly ground the unit before connecting anything else to the unit. Units not properly  
grounded may result in a safety risk and could be hazardous and may void the warranty. See the grounding  
technique section of this user manual for proper ways to ground the unit.  
WARNING: Do not work on equipment or cables during periods of lightning activity.  
WARNING: Do not perform any services on the unit unless qualified to do so.  
WARNING: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage  
polarity can cause permanent damage to the unit and void the warranty.  
(Revised 2010-11-15)  
Page 8 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ingress Protection IP67  
The classification of degrees of protection provided by the enclosures is defined by IEC 60529. Each rating  
is defined by specific tests.  
The IP number is comprised of two numbers, the first referring to the protection against solid objects and  
the second against fluids. The higher the number, the better the device is protected against contact with  
moving parts and the harmful entry of various forms of moisture.  
1st IP Protection against ingress of solids  
2nd IP  
Protection against ingress of liquids  
No protection  
Protected against vertically falling drops of water.  
No protection  
0
1
0
1
Protected against solid objects over 50mm e.g. hands,  
large tools.  
Protected against solid objects over 12mm e.g. hands,  
large tools.  
Protected against solid objects over 2.5mm e.g. wire,  
small tools.  
Protected against direct sprays of water up to 15°  
from vertical.  
Protected against direct sprays of water up to 60°  
from vertical.  
Protected against water sprayed from any direction.  
Limited ingress permitted.  
Protected against low pressure water jets from any  
direction. Limited ingress permitted.  
Protected against high pressure water jets from any  
direction. Limited ingress permitted.  
Protected against temporary immersion between  
15cm to 1m.  
2
3
4
5
6
2
3
4
5
6
7
8
Protected against solid objects over 1.0mm e.g. wires.  
Limited protection against dust ingress (no harmful  
deposit)  
Totally protected against dust ingress.  
Protected against long periods of immersion under  
pressure.  
The 708M12 Industrial Ethernet Switches are fully protected against dust and will remain sealed when  
immersed in water to a depth of 1 meter for 1 hour when all the ports are properly mated or sealed.  
These IP67 caps seal off the unused ports protecting them from dirt, water, oil or any other  
contaminants which might be present in the close proximity of the switch.  
Please make sure the 708 Series Ethernet Switch package contains the following items:  
1. 708M12 Switch  
2. Product CD  
Contact your carrier if any items are damaged.  
Installation  
Read the following warning before beginning the installation:  
WARNING  
(Revised 2010-11-15)  
Page 9 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Never install or work on electrical equipment or cabling during periods of lightning activity. Never connect  
or disconnect power when hazardous gasses are present.  
Disconnect the power cable before removing any enclosure panel.  
UNPACKING  
Remove all the equipment from the packaging, and store the packaging in a safe place. File any damage  
claims with the carrier.  
CLEANING  
Clean only with a damp cloth.  
(Revised 2010-11-15)  
Page 10 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bulkhead Mounting  
The following are the mechanical dimensions and drill hole placements to consider when mounting the  
708M12 Industrial Ethernet Switches within an enclosure:  
(Revised 2010-11-15)  
Page 11 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Front Panel  
LNK/ACT  
Link/Activity LED  
M12 D-Coded Female Ports  
M12 A-Coded Male Port  
All 8 ports are Auto sensing 10/100BaseTX  
Redundant Power Input (10-30VDC)  
Green LED lights when Power is connected  
Serial COM Port (CLI)  
M12 A-Coded Female Port  
M12 A-Coded Female Port  
NTCD-M12 (N-Tron Configuration Device)  
LED’s: The table below describes the operating modes:  
LED  
Color  
Description  
GREEN  
Power is Applied with no active faults.  
RED  
OFF  
ON  
Power is Applied with an active fault.  
Power is not Applied.  
Link established, no Activity on cable.  
No link established  
LNK  
ACT  
OFF  
BLINKING Link established, Activity on cable  
OFF  
No link established  
(Revised 2010-11-15)  
Page 12 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Applying Power  
The M12 A coded power connector is keyed, where the mating connection from the power supply  
can be made only when the male and female ends are lined up properly.  
When the power is first connected all LED‘s will flash ON Momentarily.  
Verify the Power LED stays ON (GREEN).  
Note: Either V1 or V2 can be connected to power for minimal operation. For redundant power  
operation, V1 and V2 must be connected to separate DC Voltage sources. The power cord should be  
limited to less than 10 meters in order to ensure optimum performance.  
Recommended 24V DC Power Supplies, similar to:  
100VAC/240VAC:  
N-Tron NTPS-24-1.3, DC 24V/1.3A  
(Revised 2010-11-15)  
Page 13 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-TRON 708M12 Grounding Techniques  
Drain wire with lug connecting switch chassis to known grounding point.  
CONNECTING THE UNIT  
For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the M12 connector. For  
100Base-T ports, plug a Category 5 (or greater) twisted pair cable into the M12 connector. Connect  
the other end to the far end station. Verify that the LNK LED‘s are ON once the connection has  
been completed. To connect any other port to another Switch or Repeater, use a standard Cat5  
straight through or crossover cable.  
Warning: Creating a port to port connection on the same switch (i.e. loop) is an illegal operation  
and will create a broadcast storm which will crash the network!  
(Revised 2010-11-15)  
Page 14 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SERIAL INTERFACE  
The 708M12 Switch provides an EIA-232 interface accessed via an A Coded female connector (labeled  
‗COM‘ on the unit). This is used to access the Command Line Interpreter (CLI). The pin-outs are shown  
below:  
SERIAL-DB9-M12  
Serial Cable  
Connect the serial COM port of your PC and the 708M12 Switch using N-Tron‘s SERIAL-DB9-M12 serial  
cable. You will require a cable with a 9-pin or 25-pin sub-D female connector for the PC end, and a 4-Pin A  
Coded M12 Male connector for the 708M12 end.  
The following table shows the pin-out and the connections for both types of cable:  
PC Port  
25-Pin  
9-Pin  
708M12  
Female  
Female  
4-Pin A Coded M12 Male  
Signal Name  
TXD  
Pin #  
Pin #  
Pin #  
2
1
Signal Name  
RXD  
2
3
7
3
2
5
RXD  
GND  
TXD  
GND  
3/4  
HyperTerminal  
The following configuration should be used in HyperTerminal:  
Port Settings:  
Data Bits:  
Parity:  
115200  
8
NONE  
1
Stop bits:  
Flow Control:  
NONE  
(Revised 2010-11-15)  
Page 15 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OVERVIEW OF ADVANCED FEATURES  
Mode of Operation  
Each port on the switch can be configured into different modes of operation as shown below:  
Copper Ports:  
- Half Duplex  
- Full Duplex  
100Base Fiber Ports:  
- Full Duplex  
- Auto Negotiation  
Half Duplex  
In half duplex mode, the CSMA/CD media access method is the means by which two or more stations share  
a common transmission medium. To transmit, a station waits (defers) for a quiet period on the medium (that  
is, no other station is transmitting) and then sends the intended message in bit-serial form. If, after initiating  
a transmission, the message collides with that of another station, then each transmitting station intentionally  
transmits for an additional predefined period to ensure propagation of the collision throughout the system.  
The station remains silent for a random amount of time (back-off) before attempting to transmit again.  
Full Duplex  
Full duplex operation allows simultaneous communication between a pair of stations using point-to-point  
media (dedicated channel). Full duplex operation does not require that transmitters defer, nor do they  
monitor or react to receive activity, as there is no contention for a shared medium in this mode.  
Auto Negotiation  
In Auto Negotiation mode, the port / hardware detects the mode of operation of the station that is connected  
to this port and sets its mode to match the mode of the station.  
Port Mirroring  
A Mirroring Port is a dedicated port that is configured to receive the copies of Ethernet frames that are being  
transmitted out and also being received in from any other port that is being monitored. ‗Mirrored Data Only‘  
can be selected and this selects for mirrored data only to be transmitted to the destination port, as opposed to  
mirrored data and whatever other data is otherwise destined for the destination Port.  
Port Trunking  
Port Trunking is the ability to group two network ports to increase the bandwidth between two machines  
(switch or any work station). This feature allows grouping of high-speed connectivity and provides  
redundant connection between switches, so that a trunk can act as a single link between the switches.  
Quality of Service (QoS)  
Quality of service (QoS) refers to resource reservation control mechanisms. Quality of service is the ability  
to provide different priority to different applications, users, or data flows. Quality of service guarantees are  
important if the network capacity is insufficient, especially for real-time streaming multimedia applications  
(Revised 2010-11-15)  
Page 16 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
such as voice over IP, online games and IP-TV, since these often require fixed bit rate and are delay  
sensitive, and in networks where the capacity is a limited resource, for example in cellular data  
communication. In the absence of network congestion, QoS mechanisms are not required.  
Each of these three QOS methods below is included or not based on the settings on the relevant browser  
page:  
1) Force High Priority (Port Based),  
2) IEEE802.1p (Tagged QOS), or  
3) DSCP (differentiated services code points) (RFC 2474).  
When Force High Priority is enabled, the port based priority is included in the decision for all ports and all  
frames received on a port will use the default QOS priority for that port in the decision. For example, if it is  
desired to have ingress frames on a port egress to the highest priority transmit queue regardless of other  
factors, then enable Force High Priority and the port's Priority will be 7.  
Virtual LAN  
The switch provides support for setting up tagged Virtual LANs (Local Area Networks). A port may belong  
to any number of Virtual LANs. The VLAN membership of a device is determined by the VLAN(s) that  
have been defined for the port to which the device is connected. If a device should move from one port to  
another, it loses its current VLAN membership and inherits that of the new port it is connected to.  
VLANs facilitate easy administration of logical groups of devices that can communicate as if they  
were on the same LAN. Traffic between VLANs is restricted, unless the ports are explicitly configured  
as overlapping VLANs. Switches forward unicast, multicast, and broadcast traffic only on LAN segments  
that serve the VLAN to which the traffic belongs.  
A Default Virtual LAN (VID=1) exists to which a port, which is not a member of any other Virtual LAN,  
will belong. This allows the switch to operate as a ‗normal‘ switch when it is used in a network. A port is  
automatically removed from the Default VLAN when it is reconfigured to belong to another Virtual LAN,  
because that is the most common operation. But, if desired, the port can be included in VLAN 1 by  
configuring VLAN 1 last.  
If switch ports are configured to transmit and receive untagged frames, end devices are able to communicate  
throughout the LAN. Using Tagged VLANs, the switch has the ability to take non-tagged packets in some  
ports, add a VLAN tag to the packet and send it out tagged ports on the switch. The VLANs can also be  
configured to accept tagged packets in tagged ports, strip the tags off the packets, and send the packets back  
out other untagged ports. This allows a network administrator to set up the switch to support devices on the  
network that do not support VLAN Tagged packets. The administrator can also set up the ports to discard  
any packets that are tagged or to discard any packets that are untagged based on a hybrid VLAN of both  
tagged and untagged ports, and using the VLAN Ingress Filter on the switch.  
For each switch port there is one and only one PVID (port VLAN ID) setting. If an incoming frame is  
untagged and untagged frames are being accepted, then that frame will inherit the tag of the PVID value for  
that port. Subsequent switch routing and treatment will be in accordance with that VLAN switch map. By  
configuring PVIDs properly and configuring for all frames to exit untagged, the switch can achieve a ‗port  
VLAN‘ configuration in which all frames in and out can be untagged, thus not requiring external devices to  
be VLAN cognizant.  
To understand how a VLAN configuration will perform, first look at the port on which the frame enters the  
switch, then the VLAN ID (if the frame is tagged) or the PVID (if the frame is untagged). The VLAN  
(Revised 2010-11-15)  
Page 17 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
defined by the VID or PVID defines a VLAN group with a membership of ports. This membership  
determines whether a port is included or excluded as to frame egress from the switch.  
The 708M12 Series switch also has the ability to allow overlapping VLANs. Overlapping VLANs give  
the user the ability to have one or more ports share two or more VLAN groups. For more information and  
examples on how this could be implemented, please see the ‗VLAN Configuration Examples‘ in this  
document, and/or our website‘s technical documents. Note that RSTP on overlapping VLANs is not  
supported and the system will automatically disable RSTP on all but the lowest VID VLANs that have  
overlapping ports.  
Rapid Spanning Tree Protocol  
The Rapid Spanning Tree Protocol as specified in IEEE 802.1D-2004 is supported. One Spanning Tree per  
non-overlapping VLAN is supported. The Rapid Spanning Tree Protocol (RSTP) supersedes the Spanning  
Tree Protocol (STP) which was described in IEEE 802.1D-1998. The RSTP is used to configure a simply  
connected active network topology from the arbitrarily connected bridges of a bridged network. Bridges  
effectively connect just the LANs to which their forwarding ports are attached. Ports that are in a blocking  
state do not forward frames. The bridges in the network exchange sufficient information to automatically  
derive a spanning tree.  
RSTP allows for much quicker learning of network topology changes than the older STP. RSTP supports  
new and improved features such as rapid transition to forwarding state. RSTP also sends out new BPDUs  
every hello time instead of just relaying them. RSTP interoperates with older STP switches by falling back  
to the older STP when the older BPDUs are detected on bridge ports. The user can also manually configure  
bridge ports to use the older STP when desired.  
SNMP Traps  
The 700 Series switch supports up to 5 SNMP Trap Stations to which SNMP Traps will be sent. The switch  
supports four standard traps; Link Up, Link Down, Cold Start and Warm Start. SNMP Traps will be sent to  
all the stations configured on the switch if a port Link goes up or down, when the switch first powers up and  
when the switch is reset.  
IGMP Snooping  
IGMP Snooping is enabled by default, and the switch is Plug and Play for IGMP. IGMP snooping provides  
intelligent network support for multicast applications. In particular, unneeded traffic is reduced. IGMP  
Snooping is configured via the web console and if enabled, operates dynamically upon each power up.  
Also, there can be manual only or manual and dynamic operation. Note that ―static multicast group  
address‖ can be used whether IGMP Snooping is enabled or not.  
IGMP Snooping will function dynamically without user intervention. If some of the devices in the LAN do  
not understand IGMP, then manual settings are provided to accommodate them. The Internet Group  
Management Protocol (IGMP) is a protocol that provides a way for a computer to report its multicast group  
membership to adjacent ‗routers‘. In this case N-Tron 700 Series switches provide router-like functionality.  
Multicasting allows one computer to send content to multiple other computers that have identified  
themselves as interested in receiving the originating computer's content. Multicasting can be used to  
transmit only to an audience that has joined (and not left) a multicast group membership. IGMP version 2 is  
formally described in the Internet Engineering Task Force (IETF) Request for Comments (RFC) 2236.  
(Revised 2010-11-15)  
Page 18 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
IGMP version 1 is formally described in the Internet Engineering Task Force (IETF) Request for Comments  
(RFC) 1112. The 700 Series supports v1 and v2.  
N-Ring  
N-Ring is enabled by default, and the switch is Plug and Play for N-Ring except that initially one must  
enable an N-Ring enabled device to be the N-Ring Manager for a given N-Ring. Subsequently, N-Ring  
operates dynamically upon each power up. Using N-Tron's proprietary N-Ring technology offers expanded  
ring size capacity, detailed fault diagnostics, and a standard healing time of 30ms. The N-Ring Manager  
periodically checks the health of the N-Ring via health check packets. If the N-Ring Manager stops  
receiving the health check packets, it times out and converts the N-Ring to a backbone within 30ms. When  
using all N-Ring enabled switches in the ring, a detailed ring map and fault location chart is also provided  
on the N-Ring Manager‘s web browser. N-Ring status is also sent from the N-Ring Manager to the N-View  
OPC Server to identify the health status of the ring. Up to 250 N-Ring enabled switches can participate in  
one N-Ring topology. Switches that do not have N-Ring capability may be used in an N-Ring, however the  
ring map and fault location chart cannot be as detailed at these locations.  
N-Link  
The purpose of N-Link is to provide a way to redundantly couple an N-Ring topology to one or more other  
topologies, usually other N-Ring topologies. Each N-Link configuration requires 4 switches: N-Link  
Master, N-Link Slave, N-Link Primary Coupler, and N-Link Standby Coupler. N-Link will monitor the link  
status of the Primary and Standby Coupler links. While the Primary Coupler link is healthy, it will forward  
network traffic and the Standby Coupler link will block network traffic. When a problem is detected on the  
Primary Coupler link, the Primary Coupler link will block network traffic and the Standby Coupler link will  
forward network traffic. While the N-Link Master and Slave are in communication via the Control link,  
only one Coupler link (Primary or Standby) will forward network traffic while the other Coupler link will  
block network traffic.  
CIP  
The CIP (Common Industrial Protocol) feature allows N-Tron switches to directly provide switch  
information and configuration access to Programmable Logic Controller (PLC) and Human Machine  
Interface (HMI) applications via a standardized communication protocol. For example, a PLC may be  
programmed to monitor port links or N-Ring status and cause a status indicator to turn red on an HMI if a  
port goes link down or if N-Ring has a fault. CIP is formally described in ODVA Publication Number  
PUB00001 (Volume 1: Common Industrial Protocol (CIP™)), and Publication Number: PUB00002  
(Volume 2: EtherNet/IP Adaptation of CIP). N-Tron provides EDS and ICO files. N-TRON_CIP_Tags.pdf  
is for a particular environment, but reveals the tags available.  
DHCP  
The Dynamic Host Configuration Protocol (DHCP) provides configuration parameters to Internet hosts.  
DHCP is built on a client-server model, where designated DHCP server hosts allocate network addresses  
and deliver configuration parameters to dynamically configured hosts. DHCP is controlled by RFC 2131.  
The N-Tron DHCP Switch can be configured to be a DHCP Client. Alternately the N-Tron DHCP switch  
can be configured to be a DHCP Server, a DHCP Relay Agent, or both.  
For more detailed information on N-Tron DHCP features, reference: http://www.n-tron.com/tech_docs.php.  
Under ‗White papers‘, see. ―Using DHCP to Minimize Equipment Setup Time‖. Under ‗Installation Guides  
and User Manuals‘ see ―DHCP Technical Instructions for 708 / 716/ 7018 / 7506 Series‖.  
(Revised 2010-11-15)  
Page 19 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
DHCP Client  
The switch will automatically obtain an IP assignment from a DHCP Server, or optionally Fallback to a  
configured IP assignment if unable to get an IP assignment from a DHCP server. Communication between  
the client and server can optionally go through a DHCP Relay Agent.  
DHCP Relay Agent  
DHCP Relay Agent (Option 82) allows communication between the client and server to cross subnet and  
VLAN boundries. It also allows for a device on a specific port to receive a specific IP address and if the  
device is replaced, the replacement receives the same IP address as the original device.  
DHCP Server  
DHCP Server allows DHCP Client devices to automatically obtain an IP assignment. IP assignments can be  
set up as a dynamic range of IP addresses available to any client device; or specific IP addresses based on  
the clients MAC address, Client ID (Option 61), or Relay Agent connection (Option 82).  
LLDP  
Link Layer Discovery Protocol (LLDP) is a Layer 2 discovery protocol that allows devices attached to an  
IEEE802 LAN to advertise to other devices the major capabilities they have and to store information they  
discover in a MIB that can be accessed through SNMP. LLDP is formally described in IEEE Standard -  
802.1AB.  
Port SecurityMAC Address Based  
The Port Security feature restricts access to the switch by only accepting dynamically learned MAC  
addresses and manually entered MAC addresses as authorized. Dynamically learned MAC addresses are  
those that the switch detects on any port while in ‗Learning‘ mode. A manually entered MAC address must  
designate the ports that the address is authorized on. A non-authorized MAC address will be discarded and  
will be shown on the intruder log.  
XML Settings Download  
XML settings can be downloaded to a switch to achieve some switch configurations. XML settings cover a  
subset of the settings available through the web browser. Reference Appendix A. XML Settings File Example  
for the complete set of configurations that can be done using XML Settings Download. There are several top  
level configuration sections and each of these sections is optional. Some sections have a ‗keep or delete‘  
choice such that one can load only those in the XML file deleting the pre-existing of those particular settings  
or one can add the settings in the XML file to the already existing settings. The example also shows field  
character limits, and provides other guidance.  
(Revised 2010-11-15)  
Page 20 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
TROUBLESHOOTING  
1.  
2.  
Make sure the (Power LED) is ON.  
Make sure you are supplying sufficient current for the version chosen. Note: The Inrush  
current will exceed the steady state current by ~ 2X.  
3.  
4.  
5.  
Verify that Link LEDs are ON for connected ports.  
Verify cabling used between stations.  
Verify that cabling is Category 5E or greater for 100Mbit operation.  
SUPPORT  
Contact N-Tron Corp. at:  
TEL: 251-342-2164  
FAX: 251-342-6353  
FCC STATEMENT  
This product complies with Part 15 of the FCC-A Rules.  
Operation is subject to the following conditions:  
(1) This device may not cause harmful Interference  
(2) This device must accept any interference received, including interference that may cause  
undesired operation.  
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against  
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful  
interference to radio communications. Operation of this device in a residential area is likely to cause  
harmful interference in which case the user will be required to correct the interference at his/her own  
expense.  
INDUSTRY CANADA  
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment  
Regulations. Operation is subject to the following two conditions; (1) this device digital apparatus meets  
all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to  
the following two conditions; (1) this device may not cause harmful interference, and (2) this device  
must accept any interference received, including interference that may cause undesired operation.  
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne  
causant des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce  
dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle  
interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée.  
(Revised 2010-11-15)  
Page 21 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Web Software Configuration  
Web Management  
Enter the switch‘s IP address in any web browser and login to the web management feature of the 700  
Series.  
Default:  
User Name: admin  
Password: admin  
(Revised 2010-11-15)  
Page 22 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Web Management - Home  
When the administrator first logs onto a 700 Series switch the default home page will be displayed. On the  
left hand side of the screen there is a list of configurable settings that the 700 Series switch will support.  
This section of the manual will go through each and every choice listed on the left hand side of the screen  
and explain how to configure those settings. In the center of the main home page the administrator can see  
some basic information like what firmware revision the switch is running. The firmware can be upgraded at  
a later time in the field using TFTP.  
(Revised 2010-11-15)  
Page 23 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Web Management Menu Structure  
To the left, there is a menu which is shown fully opened below. The pages opened by each of the individual  
selections are described in the rest of this section. The use of each of these pages is also described in this  
section. In most of the descriptions, only the right side of the page is shown.  
(Revised 2010-11-15)  
Page 24 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration System  
The System tab under the Administration category, lists various information about the switch:  
When the IP Configuration is in either DHCP or Static Mode:  
IP Configuration  
Method used to obtain an IP Address, Subnet Mask and Gateway Address  
IP Address  
Contains the current IP Address of the device.  
Subnet Mask  
Contains the current Subnet Mask of the device.  
Gateway  
Contains the current Default Gateway of the device.  
MAC Address  
MAC Address of the device.  
System Up Time  
This parameter represents the total time count. This time has elapsed since the switch was turned ON or RESET.  
Name  
It shows the name of the product, which allows alphanumeric and special characters (#, _, -) only.  
Contact  
The person to contact for system issues, which should be someone within your organization.  
Location  
The physical location of the switch.  
Temperature:  
The calculated ambient temperature near the switch. This calculation is only valid after a warm-up period.  
Upper Threshold:  
The highest temperature for the switch without causing a fault to occur. The threshold is specified as an integer in  
C degrees. The range is from -60°C to 100°C, and the default is product dependent.  
Lower Threshold:  
The lowest temperature for the switch without causing a fault to occur. The threshold is specified as an integer in  
C degrees. The range is from -60°C to 100°C, and the default is product dependent.  
(Revised 2010-11-15)  
Page 25 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration System, Continued…  
By selecting the Modify button from the ‗Static‘ mode, you will be able to change the switch‘s IP  
Configuration, IP Address, Subnet Mask, Gateway, Name, Contact information, and the Location of the  
switch through the web management features. It is recommended to change the TCP/IP information through  
the Command Line Interface (CLI) initially, but it defaults to the following:  
IP Configuration - Static  
IP Address 192.168.1.201  
Subnet Mask 255.255.255.0  
Gateway 192.168.1.1  
(Revised 2010-11-15)  
Page 26 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration – System, Continued…  
When the IP Configuration is in DHCP Mode the following information is added:  
Client ID  
Option used by DHCP clients to specify their unique identifier. The identifier may be the MAC address,  
switch name, or entered as a text string or hex characters.  
Fallback IP Address  
Contains the configured Fallback IP Address of the device.  
Fallback Subnet Mask  
Contains the configured Fallback Subnet Mask of the device.  
Fallback Gateway  
Contains the configured Fallback Gateway of the device.  
(Revised 2010-11-15)  
Page 27 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration – System, Continued…  
If the IP Configuration mode is set to DHCP and the Fallback IP address is changed from the default IP  
address, then the switch will use the Fallback addresses if the IP configuration isn‘t received from a DHCP  
server in 2 minutes after initial boot. If Fallback address is used, DHCP Client will stop sending requests. If  
the IP Configuration is received from a DHCP server, it will never fallback, even if the lease is lost.  
(Revised 2010-11-15)  
Page 28 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration SNMP  
The SNMP tab under the Administration category shows a list of IP Addresses that act as SNMP Traps.  
The Read-Only, Read-Write, and Trap Community Names are also shown here.  
By selecting the Modify button, you will be able to change any of the fields listed. This allows the user to  
set an IP address for a Trap station or change the Community Names. If the SNMP Notification Trap is  
enabled, systems that are listed as a Trap station will be sent the corresponding notification trap. To restore  
a Trap to ―Value Not Configured‖, enter ‗0.0.0.0‘.  
(Revised 2010-11-15)  
Page 29 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration SNMP, Continued…  
(Revised 2010-11-15)  
Page 30 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration Fault  
The Fault tab under the Administration category provides configurable selections indicating the way to  
notify when a Power or N-Link, or Port Usage, or N-Ring Signal fault occurs. The notification may consist  
of any combination of the options: Show web, Show LED, and Contact. Power faults consist of V1 and V2.  
Port Usage faults are based on the settings of Usage Alarm Low [%] and Usage Alarm High [%] thresholds  
from the Ports Configuration Page. N-Ring signal faults consist of: Broken, Partial Break (Low), Partial  
Break (High), and Multiple Managers.  
(Revised 2010-11-15)  
Page 31 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DHCP Server Setup Profiles  
The Setup Profiles tab under the DHCP/Server category lists the following information about the current  
state of the server and the existing network profiles:  
Server Enabled  
Indicates whether the DHCP server is active.  
Allow Broadcast  
Indicates whether the DHCP server will process broadcast messages.  
Delay Broadcast (Ms)  
The amount of time the DHCP server will delay processing a broadcast message.  
Server ID  
Descriptive name of the DHCP server.  
Profile Name  
Descriptive name of the network profile.  
Address Pool  
Range of IP addresses which the profile can use.  
Subnet Address  
The most restrictive subnet address calculated from the address pool range.  
Subnet Mask  
The most restrictive subnet mask calculated from the address pool range.  
Domain Name  
The domain name to be presented to the client.  
Has Profile IP Maps  
Indicates whether the profile has IP maps associated with it.  
Delete  
Deletes the profile along with all IP maps and bindings associated with it. The Default profile cannot be deleted.  
(Revised 2010-11-15)  
Page 32 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DHCP Server Setup Profiles, Continued…  
(Revised 2010-11-15)  
Page 33 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DHCP Server Setup IP Maps  
The Setup IP Maps tab provides the way to create IP mappings with an existing network profile. There are  
three types of mappings that can be created: Dynamic Range, Static Range, and Single IP.  
The Dynamic Range type of mapping is used to create a range of dynamic IP addresses for requesting  
clients. The following information is required:  
Network Profile  
An existing network profile to which the IP map applies.  
Low IP  
The starting IP address of a range.  
High IP  
The ending IP address of a range.  
(Revised 2010-11-15)  
Page 34 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DHCP Server – Setup IP Maps, Continued…  
The Static Range type of mapping is used to create a range of static IP addresses dedicated to specific ports  
on a relay agent switch. There are two different data entry formats available according to whether the relay  
agent type is for an N-TRON or for a generic switch.  
To create a range of static IP addresses on an N-Tron relay agent switch:  
Network Profile  
An existing network profile to which the IP map applies.  
Relay Agent Type  
Should be set to N-TRON.  
Switch Model  
List of N-TRON models that support this feature.  
Remote ID  
A unique identifier that designates the N-TRON relay agent switch.  
Add  
Checkbox used to add an IP map for the corresponding port.  
Port No  
The actual port number.  
Port Name  
Descriptive name of the port.  
VLAN  
VLAN ID that the port is a member of.  
Circuit ID  
Auto-generated string based on the port name and VLAN ID.  
IP Address  
IP address to assign to the IP map.  
(Revised 2010-11-15)  
Page 35 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DHCP Server – Setup IP Maps, Continued…  
(Revised 2010-11-15)  
Page 36 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DHCP Server – Setup IP Maps, Continued…  
To create a range of static IP addresses on a generic relay agent switch:  
Network Profile  
An existing network profile to which the IP map applies.  
Relay Agent Type  
Should be set to Generic.  
Port Count  
The number of ports on the particular relay agent switch.  
Add  
Checkbox used to add an IP map for the corresponding port.  
Port No  
The actual port number.  
Remote ID  
The identifier that corresponds to an Option 82 Remote ID sub-option used by the particular relay agent switch.  
Circuit ID  
The identifier that corresponds to an Option 82 Circuit ID sub-option used by the particular relay agent switch.  
IP Address  
IP address to assign to the IP map.  
(Revised 2010-11-15)  
Page 37 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DHCP Server – Setup IP Maps, Continued…  
The Single IP type of mapping is used to create a static IP address for an individual client. The following  
information is required:  
Network Profile  
An existing network profile to which the IP map applies.  
IP  
The static IP address to offer to a client.  
Unique ID  
The unique identifier that must match either the client identifier (Option 61) or the client‘s hardware address (MAC).  
Format  
Designates how the Unique ID is interpreted.  
(Revised 2010-11-15)  
Page 38 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DHCP Server View Bindings  
The View Bindings tab lists the bindings of physical devices to IP addresses that are in use or offered:  
Network Profile  
The profile applied to the binding entry.  
Binding Identifier  
The client associated with the binding entry.  
Client Hardware Address (MAC)  
The client‘s MAC address.  
Client IP Address  
The actual IP address assigned to the binding entry.  
Status  
Indicates the current status of the binding entry.  
Release  
Removes the corresponding binding.  
WARNING: By releasing an IP address, it is possible to end up with two physical devices with the same IP address  
which may cause network disruption to that IP address.  
(Revised 2010-11-15)  
Page 39 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DHCP Relay & Local IP - Setup  
The Setup tab under the DHCP/Relay & Local IP category shows the current state of the relay agent.  
By selecting the Modify button, you can configure general settings of the relay agent, as well as, configure  
settings on a per port basis. The following describes these settings:  
Relay Status  
Indicates whether the DHCP relay agent is active.  
Remote ID  
The unique identifier that designates the relay agent switch.  
Server # IP  
The configured IP address of the DHCP servers.  
Port No  
The actual port number.  
Port Name  
The descriptive name of the port.  
Relay Status  
The selection to designate whether the port will perform relay agent functionality. The choices are:  
Disabled  
The port will function without relay agent processing.  
Enabled  
Assign Local IP  
The port will relay DHCP client-originated broadcast packets to the DHCP servers.  
The port will not relay DHCP client-originated broadcast packets. Instead the relay agent  
will offer the port‘s locally assigned IP address to the client.  
(Revised 2010-11-15)  
Page 40 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DHCP Relay & Local IP – Setup, Continued…  
Other Data  
When the Relay Status is set to Enabled, the Circuit ID for the port can be specified. When the Relay Status is set to  
Assign Local IP, the IP address for the port can be specified.  
(Revised 2010-11-15)  
Page 41 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LLDP - Configuration  
Mode:  
Enables or Disables LLDP on the Switch. Default: Disabled  
Transmit Interval:  
Specifies the interval at which LLDP frames are transmitted. Default = 30 seconds.  
Transmit Hold Multiplier:  
Specifies a multiplier on the Transmit Interval when calculating a Time-to-Live value. Default = 4.  
Re-Initialization Delay:  
Specifies a minimum time an LLDP port will wait before re-initializing after setting the port to disable followed by  
setting a port to Tx-Only or Tx/Rx. This prevents excessive Notifications if someone toggles between Disabled and  
Enabled on LLDP Port settings. Default = 2 Seconds.  
Notification Interval  
Specifies the interval between successive Notifications generated by the switch. If a port sends out a notification and  
another port tries to send out a notification, the notification will not be sent until the interval expires.  
Default = 5 Seconds.  
(Revised 2010-11-15)  
Page 42 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LLDP - Ports  
LLDP Ports View  
Port Name  
Descriptive name of the port on the local switch.  
Transmit  
Enables or Disables LLDP Transmission on the switch.  
Receive  
Enables or Disables Receiving of LLDP Frames from neighbor switches.  
Allow Management Data  
Allow the Transmission of Management type information. For example: IP Address of switch, Port Description, System  
Name and Vlan information.  
Allow Notifications  
Notifications are transmitted when local or remote data changes.  
(Revised 2010-11-15)  
Page 43 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LLDP - Status  
LLDP Ports Neighbor View  
The Status View shows the results of LLDP discovery. The LLDP Ethernet frames received from neighboring ports are  
composed of a collection of data units called TLVs. Each TLV contains a defined type of information such as the Chassis ID  
described below, which contains the MAC address of the device sending the frame. The maximum number of neighbors displayed  
per port is four.  
Port Name  
The name of the local port on which the neighbor information was received.  
Neighbor MAC  
MAC address of neighbor switch. Corresponds to the LLDP Chassis ID TLV.  
Neighbor IP  
IP address of neighbor switch. Corresponds to the LLDP Management Address TLV.  
Neighbor Port Description  
Description of the neighbor Port from which the LLDP frame was sent.  
Neighbor System Name  
The system's administratively assigned name on the neighbor switch.  
Neighbor VLAN PVID  
The Port VLAN identifier (PVID) associated with the neighbor port.  
Neighbor VLAN ID/Name  
A list of all VLAN's for which the neighbor port is a member.  
Neighbor TTL  
Indicates the number of seconds that the information associated with this neighbor will be valid. Time to Live (TTL)  
(Revised 2010-11-15)  
Page 44 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LLDP - Statistics  
LLDP Local Port Statistics View  
Port Name  
Descriptive name of the port on the local switch.  
Transmitted Frames  
The total number of LLDP Frames sent out from the local switch.  
Received Frames  
Total number of LLDP frames received by the local switch.  
Discarded Frames  
The total number of frames discarded due to incorrect TLV's in frame.  
Error Frames  
Total count of all LLDP frames received with one or more detectable errors.  
Neighbor Age Outs  
Total count of the times that a neighbor's information has been deleted from the switch because the  
Time to Live (TTL) has expired.  
LLDP Port Status  
Local Port setting (Receive-Rx/Transmit-Tx/Disable).  
(Revised 2010-11-15)  
Page 45 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ports Configuration  
The Configuration tab under the Ports category will show a detailed overview of all the active ports on the  
switch. The overview will display the following information:  
Port Number  
This is the port index.  
Port Name  
This field displays the name of the port. The designation of TX is for copper ports, and FX is for fiber optic ports.  
Admin Status  
This configurable field displays the existing status of the port whether it is Enabled/Disabled.  
Link Status  
Current Link state of the port.  
Auto Negotiation State  
This configurable field displays the current auto-negotiation state whether it is Enabled/Disable.  
Port Speed  
This configurable field displays the speed of each port 10/100/1000 Mbps.  
Duplex Mode  
This configurable field displays the existing mode of the port whether it is Full Duplex/Half Duplex.  
Flow Control State  
This configurable field displays the existing flow control status of each port. When enabled, the individual port supports  
half-duplex back pressure and full-duplex flow control. The default is Disabled.  
Port State  
The current RSTP status of a port. It may contain Disable/Discarding/Learning/Forwarding.  
PVID  
This configurable field displays the existing port VLAN ID setting. The allowable range is 1-4094.  
Usage Alarm Low (%)  
The bandwidth utilization percentage below which a fault will be triggered if enabled. For half duplex the bandwidth  
utilization percentage is the sum of both RX and TX bandwidth utilization, and for full duplex this is the higher of TX or  
RX bandwidth utilization. See Port Utilization View and Port Usage Fault on Fault Configuration View.  
Usage Alarm High (%)  
The bandwidth utilization percentage above which a fault will be triggered if enabled. For half duplex the bandwidth  
utilization percentage is the sum of both RX and TX bandwidth utilization, and for full duplex this is the higher of TX or  
RX bandwidth utilization. See Port Utilization View and Port Usage Fault on Fault Configuration View.  
(Revised 2010-11-15)  
Page 46 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ports – Configuration, Continued…  
The User can click on the Port Number to configure each port individually. This will allow the user to  
change the port‘s settings for the following fields which are explained above:  
Admin Status  
Speed and Duplex  
Flow Control  
PVID  
Usage Alarm Low (%)  
Usage Alarm High (%)  
(Revised 2010-11-15)  
Page 47 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ports MAC Security Learning  
The Learning tab allows the administrator to control the learning or locking modes for the ports. ‗Locked‘  
is the secure mode. ‗Learning‘ builds an internal list of authorized MAC addresses based on an approved  
LAN. When the current mode is ‗Learning‘, no ports are secured.  
In ‗Locked‘ mode, ‗Secured Ports‘ shows the ports that are presently secured. Note: when N-Ring and/or  
N-Link are used, the N-Ring/N-Link ports will not have MAC Security enabled.  
The Modify button allows the administrator to change the current mode. When transitioning from  
‗Learning‘ to ‗Locked‘, the Address Resolution Logic (ARL) table represents the authorized MAC  
addresses, with the addition of any manually entered addresses (refer to Authorization List section below).  
Transitioning from ‗Locked‘ to ‗Learning‘, clears the ARL for all ports.  
(Revised 2010-11-15)  
Page 48 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ports MAC Security Authorization List  
The Authorization List tab allows for manual entry or deletion of authorized MAC source addresses with  
associated authorized ports.  
Selecting Modify displays the MAC Authorization Configuration page, which allows the administrator to  
add new entries, delete existing entries, or edit authorized ports of existing entries.  
Selecting Delete removes the associated entry. Selecting Add displays the MAC Authorization Entry page,  
showing default values for the administrator to modify (see below). When an entry number hyperlink is  
selected, this same page is displayed except it shows the associated MAC address and authorized ports.  
(Revised 2010-11-15)  
Page 49 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ports MAC Security Intruder Log  
The Intruder Log tab displays a list of unauthorized MAC addresses that attempted to access the secured  
device. Each intruder entry in the log is unique, and is based on the combination of MAC address, VLAN,  
and port. Only the first occurrence of the intruder is listed. The log is ordered by most recent first, based on  
the system time. The maximum number of entries is 100. If more than 100 intruders are detected, the  
oldest entries are deleted. The log is not saved through a power cycle.  
An entry can be individually removed from the log by selecting the associated Delete button. All entries or  
entries specific to a port can also be removed from the log by choosing the option in the dropdown list and  
then selecting the Clear button.  
(Revised 2010-11-15)  
Page 50 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ports Mirroring  
A mirroring port is a dedicated port that is configured to receive the copies of Ethernet frames that are being  
transmitted out and also being received in from any other port that is being monitored.  
The Mirroring tab under the Ports category displays the status including the list of Source Ports and the  
Destination Port that the Sources are being mirrored to.  
‗Mirrored Data Only‘ can be selected and this selects for mirrored data only to be transmitted to the  
destination port, as opposed to mirrored data and whatever other data is otherwise destined for the  
destination Port.  
(Revised 2010-11-15)  
Page 51 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ports Mirroring, Continued…  
Following the Modify button, you can enable the status of port mirroring and select source ports and the  
destination port that the source ports will be mirrored to.  
(Revised 2010-11-15)  
Page 52 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ports Trunking  
The Trunking tab under the Ports category displays the following details:  
Trunk Ports  
This field displays the ports associated with the trunk.  
Trunk Status  
This configurable field displays the existing status of the trunk. It can be either Enabled/Disabled.  
By selecting the Modify button, you can select a trunk group.  
Note: RSTP must be disabled in order to use the Trunking feature.  
Two ports of the same speed can constitute a valid trunk.  
Only 1 Trunk per switch can be created.  
All trunk ports must be at the same speed and duplex mode. If a port is not linked, there could be  
difficulty as to similar speed and duplex mode. It is best to hard code speed and duplex mode for  
each trunking link, at both ends.  
Do not use Trunking on an N-Ring manager. Do not connect the N-Ring to actively Trunking ports  
on an Auto Member.  
(Revised 2010-11-15)  
Page 53 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ports QOS  
The QOS decision tree chooses the highest priority Transmit Queue (TQ) of the following criteria:  
Force High Priority (Port Based) TQ mapping, IEEE 8021.p TQ mapping, or DSCP TQ mapping.  
The QOS tab under the Ports category displays the following details:  
Port Number  
This is the port index.  
Port Name  
This field displays the name of the port.  
Include DSCP  
This field displays the status of whether or not to include the RFC 2474 DSCP TOS (Type of Service) in the TQ  
decision. When enabled, the DSCP TOS is included when evaluating traffic priority.  
Include 802.1p  
This field displays the status of whether or not to include the IEEE 802.1p COS (Class of Service) in the TQ decision.  
When enabled, the IEEE 802.1p COS is included when evaluating traffic priority.  
Force High Priority  
This field displays the Force High Priority status. When enabled, the port based priority is included in the TQ decision  
for all ports and all frames received on a port will use the default QOS priority for that port in the TQ decision.  
Port Priority  
This field displays the default QOS priority for that port. This is the IEEE 802.1p COS (Class of Service) assigned to all  
untagged ingress frames, or all ingress frames if Force High Priority is enabled. The range is 0-7.  
(Revised 2010-11-15)  
Page 54 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ports QOS, Continued…  
Following the Modify button, the administrator can independently configure the ports for different QOS  
functionality. Once these fields are filled in to meet the needs of the administrator‘s network, the changes  
may be updated by clicking the Update button at the bottom of the page.  
(Revised 2010-11-15)  
Page 55 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Statistics Port Statistics  
The Ports Statistics tab under the Statistics category displays a list of MIB parameters. Each port has a  
separate counter for each parameter. This gives users the ability to see what kind of packets are going over  
which ports. At the bottom of the page for each port there are two buttons. Refresh will update the statistics  
for that port number and Clear will reset all the counters for that port number.  
(Revised 2010-11-15)  
Page 56 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Statistics Port Utilization  
The Ports Utilization tab under the Statistics category shows all the ports on the switch and will display a  
bar graph showing the percentage of bandwidth being used. These figures and bars are for a general feeling  
of what the bandwidth usage is. N-Tron recommends the use of N-View in order to get a precise bandwidth  
usage figure.  
(Revised 2010-11-15)  
Page 57 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Configuration  
Replace VID Tag with Default Port VID  
Specifies whether or not to replace the incoming VID tag with the port's designated VID.  
Perform Ingress Filtering  
Specifies whether or not to filter out ingress frames when a VID violation is detected.  
Discard Non-Tagged for Ports  
Specifies whether or not non-tagged ingress frames are dropped by the selected ports.  
Note that for convenience in most frequent use:  
Ports are deleted from group1 as each port is added to another group.  
Ports are added to group1 if a deletion leaves a port with no group.  
If it is desired to have a port on group1 and also on other group(s) configure group1 last to achieve that.  
(Revised 2010-11-15)  
Page 58 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
(Revised 2010-11-15)  
Page 59 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN Group Configuration  
VLAN ID  
This field displays the VLAN ID. The range should be 1-4094.  
VLAN Name  
This configurable field displays the name of the VLAN, which accepts alphanumeric and special characters (#, _, -, .)  
only.  
Allow Management  
Specifies whether or not all ports in this VLAN are management ports.  
Change PVID of Member Ports  
Specifies whether or not the PVID of the member ports is set to this VLAN ID.  
Port No  
This is the port index.  
Port Name  
Descriptive name of the port  
Group Member  
Specifies whether or not the port is included in the group.  
Untag on Egress  
Specifies whether or not egress frames are tagged by the designated port.  
(Revised 2010-11-15)  
Page 60 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bridging Aging Time  
The Aging Time tab under the Bridging category will display the currently configured Aging Time. This  
page allows users to modify this variable to meet their needs.  
After selecting the Modify button, the user will be presented with a page that allows the number to be  
entered and updated. The default aging time is 20 seconds.  
Note: If the switch is an active participant of an N-Ring, then the N-Ring Aging Time will be used instead  
of the Bridging Aging Time.  
(Revised 2010-11-15)  
Page 61 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Bridging Unicast Addresses  
The Unicast Addresses tab under the Bridging category will display a list of MAC addresses that are  
associated with each respective port number. This can be used to statically assign a MAC address access to  
a single port on the switch.  
Following the Add button on the page above, the administrator must enter a valid MAC address and  
associate it with a port number on the switch. Once the administrator hits the Add button, the changes will  
take effect instantly.  
(Revised 2010-11-15)  
Page 62 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Bridging Unicast Addresses, Continued…  
Once a static MAC address has been added, it will be displayed in a list on the main page under Unicast  
MACs tab.  
Following the Remove button on the example above, an administrator can select a static MAC address from  
the list using a pull-down menu. After selecting the MAC address, the administrator needs to press the  
Remove button on the page to remove the entry  
(Revised 2010-11-15)  
Page 63 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bridging Multicast Addresses  
The Multicast Addresses tab under the Bridging category will display a list of Multicast Group Addresses  
that are associated with respective port numbers. This may be used to statically assign a Multicast Group  
Address access to a group of ports on the switch.  
Following the Add button on the page above, the administrator must enter a valid Multicast Group Address  
and associate it with a port number or list on the switch. Once the administrator clicks on the Add button,  
the changes will take effect instantly.  
Note: If there are multiple ports on different VLANs, the 708 will apply the static multicast address to the  
lowest VLAN-ID that is associated with one of the ports assigned to the static multicast address. So  
if the lowest VLAN-ID contains all the ports assigned to the static multicast address (an umbrella  
VLAN), it will function for all those ports with no problems. This can be achieved with overlapping  
VLANs.  
(Revised 2010-11-15)  
Page 64 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Bridging – Multicast Addresses Continued…  
After adding a Multicast Group Address, it will appear on the main list and will show the associated ports  
that go along with that address.  
Following the Remove button on the example above, the administrator will be presented with a list of  
Multicast Group Addresses that are configured on the switch. Using the pull-down menu, the administrator  
should select the desired address to be removed. Then click on the Remove button at the bottom of the  
page.  
Note: If there are multiple ports on different VLANs, the 708 will apply the static multicast address to the  
lowest VLAN-ID that is associated with one of the ports assigned to the static multicast address. So  
if the lowest VLAN-ID contains all the ports assigned to the static multicast address (an umbrella  
VLAN), it will function for all those ports with no problems. This can be achieved with overlapping  
VLANs.  
(Revised 2010-11-15)  
Page 65 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bridging Show MAC by Port  
This feature shows the MAC addresses of devices connected to each switch port and the IP Addresses  
associated with the MACs. The browser page ‗View MAC by Portshows the MAC for the device found  
on each port, and the IP for the MAC presented if available. If more than one device is on that port, then the  
lowest alphanumeric of those MAC addresses is shown and underlined.  
The ‗Active IP Probe‘ field is configurable using the ‗Modify‘ button, and also displays the existing  
Enabled or Disabled status of this feature. The default is disabled. When disabled the switch generates no  
Ethernet traffic for this purpose, but can still present some information gathered passively.  
The ‗IP‘ field shows an Auto-detected or manually entered IP address. If there is a MAC address for the port  
and an IP address was not discovered there is an ‗Assign IP‘ button to allow the user to enter an IP address.  
If ‗Active IP Probe‘ is enabled, manually entered IP values are underlined and validated. A validated IP for  
that MAC is presented in green and if validation fails the IP will be red and underlined. Note that some  
devices do not have an IP Address, and that some devices that do have an IP Address may not respond to the  
methods used to detect their IP Address.  
(Revised 2010-11-15)  
Page 66 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Invoking the ‗Assign IP‘ button on the example above, the administrator will be presented with a form in  
which to enter a manually assigned IP, as below:  
When an IP has been manually entered a button is provided to ‗Delete IP‘, and invoking it will allow the  
administrator to delete the manual association of an IP to that MAC.  
(Revised 2010-11-15)  
Page 67 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RSTP Configuration  
The Configuration tab under the RSTP category will display the RSTP information for the first VLAN.  
Using the pull-down menu at the top of the page an administrator can choose which VLAN to configure  
RSTP on. Once the VLAN is selected, the administrator may configure the bridge by clicking on the  
‗Configuration‘ link in the middle of the page.  
(Revised 2010-11-15)  
Page 68 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
RSTP – Configuration Continued…  
The configuration screen for the VLAN that was previously selected will look like the example below. Here  
the administrator can make changes such as the Hello Time, Forward Delay, Max Age, Priority, and the  
Status of RSTP on that VLAN. The administrator or user can see the current RSTP status of the ports on  
that VLAN by clicking on the ‗here‘ link to view RSTP Port Configuration at VLAN#.  
Note: It is recommended that RSTP rings consist of RSTP capable switches.  
Trunking must be disabled in order to use RSTP.  
Do not create redundant links unless either RSTP or N-Ring is enabled.  
RSTP on overlapping VLANs is not supported and the system will automatically disable RSTP on the  
VLAN that has overlapping ports.  
(Revised 2010-11-15)  
Page 69 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RSTP – Configuration Continued…  
Following the link for the view RSTP Port Configuration at VLAN#, the administrator or user can see the  
current RSTP status of the ports on that VLAN. This will show information such as the Path Cost and the  
Port State. If the switch sees a redundant path it will put the port with the highest Path Cost into Blocking  
mode where it will discard packets coming in on that port. In the example below, TX3 is a redundant port  
with port TX2, therefore TX2 is forwarding and TX3 is discarding.  
If the administrator selects one of the ports on the previous screen, he or she can change the Port‘s Path  
Cost, Priority, and the status of Admin Edge and Auto Edge.  
(Revised 2010-11-15)  
Page 70 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IGMP Configuration  
The Configuration tab under the IGMP category will display the IGMP basic configuration settings. By  
default, IGMP is enabled.  
Following the Modify button, the administrator will see a list of configurable fields for the IGMP  
configuration. Once these fields are filled in to meet the needs of the administrator‘s network, the changes  
may be updated by clicking the Update button at the bottom of the page.  
(Revised 2010-11-15)  
Page 71 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IGMP Configuration, Continued…  
The IGMP Status pull-down allows the user to enable or disable IGMP completely.  
The Query Mode pull-down allows the user to set query mode for Automatic (the default), On (always), or  
Off (never):  
(Revised 2010-11-15)  
Page 72 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IGMP Configuration, Continued…  
The Router Mode pull-down allows the user to choose router mode. ‗Auto‘ allows for dynamically detected  
and manually set router ports. ‗Manual‘ allows only for manually set router ports. ‗None‘ allows no router  
ports.  
The user can specify the manual router ports:  
(Revised 2010-11-15)  
Page 73 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IGMP Show Group and Show Router  
The Show Groups tab under the IGMP category will display a list of IGMP groups based on the Group IP  
and the port number that it is associated with.  
The Show Routers tab under the IGMP category will display a list of Auto-detected Router IPs and the port  
numbers that they are associated with.  
(Revised 2010-11-15)  
Page 74 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IGMP RFilter  
The ‗rfilter‘ (Router Multicast Data Filter) function allows you to choose whether or not DATA frames  
with KNOWN group multicast addresses are sent to the ‗router‘ ports (links to other switches). Control  
packets (Join, Leave) will be sent to the router(s) regardless of this setting. ―KNOWN‖ is known from  
dynamic IGMP Snooping operations.  
The factory default is that the Router Multicast Data Filter is enabled for all ports, so any router ports do  
NOT get DATA frames with KNOWN multicast destination addresses unless a join to a specific multicast  
address has been received on that port. Joins override an rfilter.  
If rfilter is disabled, router ports do get DATA frames with KNOWN multicast destination addresses  
Rfilter can be set for individual ports: any, all, or none. For each port, rfilter will have an impact only if that  
port is manually or dynamically chosen as a router port.  
Default configuration:  
(Revised 2010-11-15)  
Page 75 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IGMP RFilter, Continued…  
Modifying rfilter port settings:  
(Revised 2010-11-15)  
Page 76 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-View Configuration  
The Configuration tab under the N-View category will display two basic variables for N-View, the status  
and the interval between packets.  
Following the Modify button on the above example, the administrator can modify the variable to change the  
frequency with which N-View reports information. Increasing the interval will slow the update rate.  
Decreasing the interval will allow N-View to report more frequently. Additionally, you may Disable or  
Enable N-View altogether.  
(Revised 2010-11-15)  
Page 77 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-View Ports  
The Ports tab under the N-View category will display a list of all the configured ports on the 708 unit along  
with the ports transmitting multicast packets and MIB stats respectively.  
Following the Modify button on the above example, the administrator can modify these two variables to  
enable or disable multicast out of the port and if MIB stats are sent out for those ports.  
(Revised 2010-11-15)  
Page 78 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-Ring Configuration  
The Configuration tab under the N-Ring category will display the N-Ring basic configuration settings. By  
default, N-Ring is in Auto Member mode and the N-Ring Aging Time is 20 seconds.  
Following the Modify button on the above example, the administrator will see a list of configurable fields  
for the N-Ring configuration, as below.  
The N-Ring Aging Time has a default of 20 seconds and is separate from the Bridging Aging Time. N-Ring  
Aging Time is used when the switch is an N-Ring Manager or becomes an active N-Ring Member, and in  
either case N-Ring status includes for example:  
“Switch is currently using N-Ring Aging Time = 20 Seconds”  
Once these fields are filled in to meet the needs of the administrator‘s network, the changes may be saved by  
clicking the Update button at the bottom of the page.  
NOTES:  
1. N-Ring Manager cannot have RSTP or Trunking enabled.  
2. RSTP & N-Ring are different modes and cannot share links or segments along those lines.  
See the examples in the RSTP configuration section.  
3. Do not use Trunking on an N-Ring manager. Do not connect the N-Ring to actively Trunking  
ports on an Auto Member.  
4. Do not create redundant links unless either RSTP or N-Ring is enabled.  
5. Any one 708 can only participate in one N-Ring.  
6. N-Ring copper ports must be run at 100Mb full duplex, including the default ‘autonegotiate’ as  
long as all switches in the ring support 100Mb full duplex.  
(Revised 2010-11-15)  
Page 79 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-Ring Configuration, Continued…  
The ―N-Ring Mode‖ is one of three, as below:  
If N-Ring Mode is ―Manager‖, then a pull-down allows selection as available of ports TX1 and TX2, or  
TX7 and TX8 (FX1 and FX2 on 708FX2) as N-Ring ports.  
(Revised 2010-11-15)  
Page 80 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Ring Configuration, Continued…  
If N-Ring Mode is ―Manager‖, then VLAN ID can be set to a unique VLAN id (1 ~ 4094). Default is 3333.  
If N-Ring Mode is ―Manager‖, then a pull-down allows selection as to whether the N-Ring ports are  
members of the VLANs Tagged or Untagged ports. Default is Tagged.  
Once these fields are filled in to meet the needs of the administrator‘s network, the changes may be saved by  
clicking the Update button at the bottom of the page.  
NOTES:  
1. Since VLANs are implemented for security reasons as well as traffic flow, N-Ring only makes  
minimal changes. It is up to the administrator to ensure that VLANs are configured correctly on the  
N-Ring manager and all N-Ring members.  
2. When the N-Ring manager and all N-Ring Members are in defaults, changing the N-Ring manager  
to use a Tagged VLAN requires no user interaction to allow non-ring traffic to pass through the ring.  
This works because changing to a Tagged VLAN does not remove the ring ports from the default  
VLAN.  
3. When the N-Ring manager and all N-Ring Members are in defaults, changing the N-Ring manager  
to use an Untagged VLAN other than VID 1, requires the administrator to add non-ring ports to the  
N-Ring VLAN to allow non-ring traffic to pass through the ring. This occurs because the N-Ring  
ports must be removed from VID 1 because an untagged port may only be a member of one VLAN.  
(Revised 2010-11-15)  
Page 81 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Ring Advanced Configuration  
If switch is an N-Ring Member, the following data will be shown:  
N-Ring Mode  
Current N-Ring mode of switch.  
Keep-Alive Timeout:  
Keep-Alive timeout is used when switch is active in an N-Ring. The range is 5-1000000 seconds.  
If switch is an N-Ring Manager, the following advanced configuration data will be shown:  
N-Ring Mode  
Current N-Ring mode of switch.  
Self Health Packet Interval:  
The amount of time to wait in milliseconds before sending Self-Health packets. The default is 10.  
Maximum Missed Packets  
The number of missed Self-Health packets that constitute a fault. The default is 2.  
Sign-On Delay  
The amount of time to wait in milliseconds before requesting initial sign-on information from ring members. The default  
is 1000.  
Sign-On Match Packets  
The number of times the switch count must match before starting the sign-on process. The default is 3.  
Sign-On Interval  
The interval of time to wait in milliseconds before requesting subsequent sign-on information from ring members when  
the ring is broken. The default is 3000.  
Sign-On Info Spacing Multiplier  
The amount of time to wait in milliseconds, scaled by switch number, before sending information to the ring manager.  
The default is 5.  
Sign-On Info Retry Timeout  
The amount of time the ring member will wait in milliseconds for the ring manager to acknowledge receipt of the  
member's information before the member tries to re-send the information. The default is 1500.  
Delay Before Re-Entering Broken State  
The amount of time, in milliseconds, that must elapse before the ring is allowed to go back into the broken state. The  
default is 3000.  
(Revised 2010-11-15)  
Page 82 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-Ring Advanced Configuration, Continued…  
(Revised 2010-11-15)  
Page 83 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Ring Status  
The Status tab under the N-Ring category will display the N-Ring status.  
Below is an example of N-Ring Status from a switch in defaults (N-Ring Auto Member) that is not an  
N-Ring Manager and has not become an ―Active‖ N-Ring Member:  
Below is an example of N-Ring Status from an ―Active‖ N-Ring Member:  
(Revised 2010-11-15)  
Page 84 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-Ring Status, Continued…  
Below is an example of N-Ring Status from an N-Ring Manager with a healthy N-Ring:  
(Revised 2010-11-15)  
Page 85 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Ring Status, Continued…  
Below is an example of N-Ring Status from an N-Ring Manager with a faulted N-Ring. The red fields on  
the N-Ring Map show problems. Ports that are red indicate that the port is not linked. MAC addresses that  
are red indicate that there is no communication to that switch. The red ―Ring Broken‖ line shows where the  
N-Ring is broken.  
(Revised 2010-11-15)  
Page 86 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Ring Status, Continued…  
In rare cases an N-Ring can have a ―Partial Fault‖. An example of this is to have a break in just one fiber in  
a duplex channel fiber pair. The screenshot below shows N-Ring Manager Status when a ‗Higher‘ N-Ring  
Port (TX2, TX8/FX2) is not receiving self health frames all the way around the N-Ring, though the other  
(low TX1, TX7/FX1) N-Ring port is:  
The screenshot below shows N-Ring Manager Status when a ‗Lower‘ N-Ring Port (TX1 or TX7/FX1) is not  
receiving self health frames all the way around the N-Ring, though the other (high TX2 of TX8/FX2)  
N-Ring port is:  
(Revised 2010-11-15)  
Page 87 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Link Configuration  
The purpose of N-Link is to provide a way to redundantly couple an N-Ring topology to one or more other  
topologies, usually other N-Ring topologies. Each N-Link configuration requires 4 switches: N-Link  
Master, N-Link Slave, N-Link Primary Coupler, and N-Link Standby Coupler.  
Standard N-Link Configuration (Example):  
N-Ring  
Auto  
Member  
N-Ring  
Auto  
Member  
N-Rng  
Manager  
N-Ring #1  
Control Port  
Default: TX3  
Control Port  
(Auto-Detected)  
Control  
Link  
N-Link Master  
Partner Link  
N-Link Slave  
N-Ring Member  
(N-Ring Segment)  
N-Ring Member  
Coupler Port  
(Default: TX4)  
Coupler Port  
(Default: TX4)  
Partner Port  
(Auto-Detcted)  
Partner Port  
(Auto-Detcted)  
Primary  
Coupler  
Link  
Standby  
Coupler  
Link  
Coupler Port  
Coupler Port  
(Auto-Detected)  
(Auto-Detected)  
N-Link Couper  
N-Ring Member  
N-Link Coupler  
N-Ring Member  
N-Ring  
Auto  
Member  
N-Ring  
Auto  
Member  
N-Ring #2  
N-Rng  
Manager  
For convenience, a diagram similar to the above is provided in the switch‘s browser help for N-Link.  
(Revised 2010-11-15)  
Page 88 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-Link Configuration, Continued…  
Complex N-Link Configuration (Example):  
N-Ring  
Auto  
Member  
N-Ring  
Auto  
Member  
N-Rng  
Manager  
N-Ring #1  
Control  
Link #1  
Control  
Link #2  
Control  
Link #3  
N-Ring AM  
N-Link Master  
#1  
N-Ring AM  
N-Link Slave  
#1  
N-Ring AM  
N-Link Master  
#2  
N-Ring AM  
N-Link Slave  
#2  
N-Ring AM  
N-Link Master  
#3  
N-Ring AM  
N-Link Slave  
#3  
Partner  
Link #1  
Partner  
Link #2  
Partner  
Link#3  
Primary  
Coupler  
Link #1  
Standby  
Coupler  
Link #1  
Primary  
Coupler  
Link #2  
Standby  
Coupler  
Link #2  
Primary  
Coupler  
Link #3  
Standby  
Coupler  
Link #3  
N-Link AC  
N-Ring AM  
N-Link AC  
N-Ring AM  
N-Link AC  
N-Ring AM  
N-Link AC  
N-Ring AM  
N-Link AC  
N-Ring AM  
N-Link AC  
N-Ring AM  
N-Ring #2  
N-Ring #3  
N-Ring #4  
N-Ring  
Auto  
Member  
N-Ring  
Auto  
Member  
N-Ring  
Auto  
Member  
N-Ring  
Auto  
Member  
N-Ring  
Auto  
Member  
N-Ring  
Auto  
Member  
N-Rng  
Manager  
N-Rng  
Manager  
N-Rng  
Manager  
Configuration Notes:  
The Master and Slave must be part of the N-Ring topology.  
If using default configuration choices, the administrator only needs to configure the N-Link Master.  
The N-Link Slave and both Coupler switches will auto-detect any needed configuration.  
If not using default configuration choices, the administrator may also need to configure the Default  
Coupler port on the N-Link Slave.  
There must be a direct link between the Master and Slave Control ports. Use of media converters or  
other switches is not supported.  
There must be a direct link between the Master and Slave Partner ports. Use of media converters or  
other switches is not supported.  
There must be at least one other switch, besides the Master and Slave, that supports N-Link on the  
N-Ring.  
N-Link will only support a single point of failure. Multiple points of failure and misconfiguration  
are not supported and may cause a network storm under some circumstances.  
Configuration Steps to redundantly couple 2 N-Ring networks:  
1. Ensure the Coupler and Control cables are disconnected at this point.  
2. Get Both N-Rings working with a status of OK.  
3. Configure N-Link Slave: Ensure that the N-Link Slave is set to Auto Configure and select a Default  
Coupler Port. Save Configuration.  
4. Configure N-Link Master: Select the Control and Coupler ports. Save the Configuration.  
5. Connect the Control Link cable. Ensure that the Slave switch status now shows a state of ―Slave‖  
6. Connect the Coupler Link cables.  
7. Check N-Link status by selecting the N-Link Status View page.  
(Revised 2010-11-15)  
Page 89 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Link Configuration, Continued…  
The Configuration tab under the N-Link category will display the configuration settings. By default, N-  
Link is in Auto Configure mode and will use TX4 as the Default Coupler port.  
Following the Modify button on the above example, the administrator will see a list of configurable fields  
for the N-Link configuration, as below.  
The port configured as the Default Coupler Port will be used as the Standby Coupler port if the switch  
detects an N-Link Master and becomes an N-Link Slave.  
Once these fields are filled in to meet the needs of the administrator‘s network, the changes may be saved by  
clicking the Update button at the bottom of the page.  
(Revised 2010-11-15)  
Page 90 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Link Configuration, Continued…  
The ―N-Link Mode‖ is one of two choices, as below:  
If N-Link mode is ―Master‖, then the administrator must configure the Control Port (default: TX3) and the  
Primary Coupler Port (default: TX4).  
Once these fields are filled in to meet the needs of the administrator‘s network, the changes may be saved by  
clicking the Update button at the bottom of the page.  
(Revised 2010-11-15)  
Page 91 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Link Status  
The Status tab under the N-Link category will display the N-Link status.  
If the switch is an N-Link Master or Slave, the following switch status and partner status information will be  
shown. Fields with a red background designate a fault condition.  
Current N-Link mode of switch.  
State:  
The port being used to convey control information. There must be a  
direct link between the Master and Slave Control ports. Use of media  
converters or other switches is not supported.  
Control Port:  
The port being used for normal communication between the N-Link  
Master and N-Link Slave switch. There must be a direct link between  
the Master and Slave Partner ports. Use of media converters or other  
switches is not supported. This port will be detected automatically.  
Partner Port:  
The port being used to establish a redundant path for Ethernet data  
transmission.  
Coupler Port:  
Blocking, Forwarding.  
Coupler Port State:  
Status:  
No errors will show "OK", otherwise a description of the Faults  
detected.  
N-Link Partner Information  
Current N-Link mode of switch.  
State:  
The MAC Address of the N-Link Partner switch.  
Blocking, Forwarding.  
MAC:  
Coupler Port State:  
Status:  
No errors will show "OK", otherwise a description of the Faults  
detected.  
If switch is an N-Link Auto Configure and not a Slave, the Coupler port, if known, will be shown.  
Current N-Link mode of switch.  
N-Link State:  
Coupler Port:  
The port used to establish a redundant path for Ethernet data  
transmission. This port will be detected automatically.  
Below is an example of N-Link Status from a switch in defaults (N-Link Auto Configure) that is not an  
N-Link Master and has not become an N-Link Slave or an N-Link Coupler:  
(Revised 2010-11-15)  
Page 92 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
N-Link Status, Continued…  
Below is an example of N-Link Status from an N-Link Coupler switch:  
Below is an example of N-Link Status from an N-Link Master switch:  
(Revised 2010-11-15)  
Page 93 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Link Status, Continued…  
Below is an example of N-Link Status from an N-Link Slave switch:  
Below is an example of N-Link Status from an N-Link Master and Slave where the Primary Coupler link is  
broken:  
(Revised 2010-11-15)  
Page 94 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Link Status, Continued…  
Below is an example of N-Link Status from an N-Link Master and Slave where the Standby Coupler link is  
broken:  
Below is an example of N-Link Status from an N-Link Master and Slave where the Control link is broken:  
(Revised 2010-11-15)  
Page 95 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-Link Status, Continued…  
Below is an example of N-Link Status from an N-Link Master and Slave where the Partner link is broken:  
(Revised 2010-11-15)  
Page 96 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CIP Configuration  
The Configuration tab under the CIP category will display basic variables for CIP, and the status:  
Cip Status:  
Enables or Disables CIP on the Switch. Default: Enabled.  
Multicast RPI:  
The minimum Requested Packet Interval for Class 1 (multicast) connections, in milliseconds.  
Requests for less than this value will be rejected. Default = 1 second.  
Unicast RPI:  
The minimum Requested Packet Interval for Class 3 (unicast) connections, in milliseconds.  
Requests for less than this value will be rejected. Default = 1 second.  
Following the Modify button on the above example, the administrator can modify the variables.  
Additionally, you may Disable or Enable CIP altogether.  
(Revised 2010-11-15)  
Page 97 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CIP Status  
The Status tab under the CIP category will display the CIP status.  
The following switch status and partner status information will be shown:  
Identity Information:  
Switch Model Number.  
Product Name:  
Vendor:  
This is N-Tron's ODVA Ethernet/IP Vendor ID (1006).  
The ODVA Device Type is Communications Adapter (= 0x0C hex).  
The Major Revision of the CIP implementation.  
The Minor Revision of the CIP implementation.  
Device Type:  
Major Revision:  
Minor Revision:  
Serial Number (hex):  
CIP Serial number, unique across all N-Tron CIP devices. This is the  
last 4 octets of the base switch MAC.  
Connection Information:  
Number of Multicast  
Current number of CIP Ethernet/IP class 1 (multicast) connections.  
Connections:  
Number of Unicast  
Connections:  
Current number of CIP Ethernet/IP class 3 (unicast) connections.  
(Revised 2010-11-15)  
Page 98 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Firmware/Config TFTP  
The TFTP tab under the Firmware/Config category gives the administrator the ability to upload or download  
a config file for a 700 Series switch. This allows administrators to backup their configurations to a server  
offsite in case they need to reload their custom configurations at a later time. Administrators are also given  
the ability to flash the switch allowing them to update the firmware in the field without losing their current  
configurations and without having to send the unit back to N-Tron for updates in the future. It is important  
not to cycle power on the switch or interrupt the data connection between the TFTP server and the switch  
while you are flashing or uploading/downloading a config file. The switch will not stop working if this does  
occur, but the administrator will have to retransfer the file. Also, an XML file can be downloaded to a  
switch to achieve some switch configurations. XML settings cover a subset of the settings available through  
the web browser. Reference Appendix A. XML Settings File Example for the complete set of configurations  
that can be done using XML Settings Download.  
(Revised 2010-11-15)  
Page 99 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Firmware/Config TFTP, Continued…  
In some cases the administrator may choose to upload or down load only certain configuration settings or to  
retain his current network settings. These choices are available as below. For more detail on the choices,  
reference „Help – Firmware/Configin this user manual or from the actual switch.  
(Revised 2010-11-15)  
Page 100 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Support Web Site and E-mail  
If at any point in time you get confused or would like additional support directly from N-Tron, you may  
visit N-Tron‘s web site, or e-mail N-Tron directly with the links provided for more information.  
(Revised 2010-11-15)  
Page 101 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
BPCL Broadcast Packet Count Limit Configuration  
The BPCL link will display all the ports that are installed in the 700 Series unit and will list the BPCL  
Percentage for each port. BPCL defaults to 3%. A Modify button is provided to change these fields.  
Following the Modify button on the above example, the administrator can modify the BPCL Percentage for  
each and every port.  
(Revised 2010-11-15)  
Page 102 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User Management Adding Users  
The User Management link will display a list of all the users who have access to the management features of  
the switch and their access permissions.  
Following the Add button on the above example, the administrator can add another user and assign the user  
a username, a password, and the user‘s permissions (user/administrator).  
A page should display after the administrator clicks the Add button indicating that the user was successfully  
added.  
(Revised 2010-11-15)  
Page 103 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User Management Removing Users  
In order to remove a user, simply click on the Remove button at the bottom of the page.  
Following the Remove button on the above example, the administrator can remove a user by entering in the  
user‘s name and clicking the Remove button.  
A page should follow indicating that the user was successfully removed from the list.  
Note: There are a maximum number of 5 users per switch. User permissions have the right to view switch  
configurations and to view current port settings, but cannot make any changes to these settings.  
Admin permissions have the right to change and view any switch configuration and to change and  
view any current port settings.  
(Revised 2010-11-15)  
Page 104 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LogicalView  
The 708M12 Web Management offers a logical view of the switch. Here a user or administrator can see a  
graphical depiction of the 708M12 switch. Ports that are linked will appear in green, while ports that are not  
linked will appear in black. The example below shows ports 1, 2, and 8 linked. The other ports are  
currently in the down state (not being used). The NTCD-M12 connection at the lower left will be green as  
below only if a configuration device is present.  
(Revised 2010-11-15)  
Page 105 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Save or Reset  
The Configuration section of web management gives an administrator the ability to save a running  
configuration into the NVRAM. This step is needed in order for the switch to remember any changes after a  
power cycle.  
The ―Save‖ button will save all current changes to the configuration for use after the next power cycle.  
Note: The current configuration will also be saved to the configuration device when connected. This  
page reveals whether the configuration device is installed or not.  
The ―Reset‖ button will discard all unsaved changes, reset the switch and load the most recently saved  
configuration settings. Note: Upon restart, if a configured configuration device is connected, the switch  
will load the configured settings from it and save them into NVRAM.  
The ―Factory‖ button will reload N-Tron‘s factory default configuration settings. Doing so will reconfigure  
the 700 Series switch to factory defaults. In many cases it is desirable to restore factory defaults but retain  
the IP address, subnet mask, and gateway address settings as well as user names and passwords.  
Checkboxes are provided to select the desired behavior. Note: The factory default configuration settings  
will also be saved to the configuration device when connected.  
(Revised 2010-11-15)  
Page 106 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help Overview  
When the Help link is clicked on, you will see the Overview page that will have some basic definitions and  
more specific choices at the top of the screen. Although this page is not as detailed as the manual, it gives  
you a basic feel for different features the 708M12 offers.  
(Revised 2010-11-15)  
Page 107 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help Administration  
Following the Administration link on the help page, the administrator or user can see some information  
regarding the configuration options in the Administration category on the left side of the web management.  
(Revised 2010-11-15)  
Page 108 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help DHCP  
Following the DHCP link on the help page, the administrator or user can see some information regarding the  
configuration options under the DHCP categories on the left side of the web management.  
(Revised 2010-11-15)  
Page 109 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help LLDP  
Following the LLDP link on the help page, the administrator or user can see some information regarding the  
configuration options in the LLDP category on the left side of the web management.  
(Revised 2010-11-15)  
Page 110 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help Ports  
Following the Ports link on the help page, the administrator or user can see some information regarding the  
configuration options in the Ports category on the left side of the web management.  
(Revised 2010-11-15)  
Page 111 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help Statistics  
Following the Statistics link on the help page, the administrator or user can see some information regarding  
the configuration options in the Statistics category on the left side of the web management.  
(Revised 2010-11-15)  
Page 112 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help VLAN  
Following the VLAN link on the help page, the administrator or user can see some information regarding  
the configuration options in the VLAN category on the left side of the web management.  
(Revised 2010-11-15)  
Page 113 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help Bridging  
Following the Bridging link on the help page, the administrator or user can see some information regarding  
the configuration options in the Bridging category on the left side of the web management.  
(Revised 2010-11-15)  
Page 114 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help RSTP  
Following the RSTP link on the help page, the administrator or user can see some information regarding the  
configuration options in the RSTP category on the left side of the web management.  
(Revised 2010-11-15)  
Page 115 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help IGMP  
Following the IGMP link on the help page, the administrator or user can see some information regarding the  
configuration options in the IGMP category on the left side of the web management.  
(Revised 2010-11-15)  
Page 116 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help N-View  
Following the N-View link on the help page, the administrator or user can see some information regarding  
the configuration options in the N-View category on the left side of the web management.  
(Revised 2010-11-15)  
Page 117 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help N-Ring  
Following the N-Ring link on the help page, the administrator or user can see some information regarding  
the configuration options in the N-Ring category on the left side of the web management.  
(Revised 2010-11-15)  
Page 118 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help N-Link  
Following the N-Link link on the help page, the administrator or user can see some information regarding  
the configuration options in the N-Link category on the left side of the web management.  
(Revised 2010-11-15)  
Page 119 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help CIP  
Following the CIP link on the help page, the administrator or user can see some information regarding the  
configuration options in the CIP category on the left side of the web management.  
(Revised 2010-11-15)  
Page 120 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help Firmware/Config  
Following the Firmware/Config link on the help page, the administrator or user can see some information  
regarding the configuration options in the Firmware/Config category on the left side of the web  
management.  
(Revised 2010-11-15)  
Page 121 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help BPCL  
Following the BPCL link on the help page, the administrator or user can see some information regarding the  
configuration options in the BPCL category on the left side of the web management.  
(Revised 2010-11-15)  
Page 122 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help User Management  
Following the User Management link on the help page, the administrator or user can see some information  
regarding the configuration options in the User Management category on the left side of the web  
management.  
(Revised 2010-11-15)  
Page 123 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Help Other  
Following the Other link on the help page, the administrator or user can see some information regarding  
other links or categories on the left hand side of the web manager, as above.  
(Revised 2010-11-15)  
Page 124 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CLI Commands  
―?‖ (Help)  
Command Name  
Description  
―?‖  
Show a list of all commands or get help on a specific command.  
Without cmd, this command will list all the available commands.  
If cmd is specified and if it matches a specific command, the usage of the command will  
be displayed; otherwise, if cmd matches the prefix of a command, the name of the  
command will be listed.  
If ? is preceded by another ?, the usage and description of this command will be  
displayed.  
? [cmd]  
cmd  
Syntax  
Parameters  
The command for which to get help.  
N-TRON/Admin> ?  
The above command displays all the available commands.  
Examples  
N-TRON/Admin> abcd ?  
Unknown Command: "abcd"  
Type "?" for a list of available commands.  
N-TRON/Admin> logout ?  
Logout  
Log out of console interface.  
SYNTAX:  
Logout  
N-TRON/Admin> ? pi  
Ping  
Ping a host.  
N-TRON/Admin> ? ?  
?
Show a list of all commands or get help on a specific  
command.  
SYNTAX:  
? [cmd]  
OPTIONS:  
cmd : The command for which to get help.  
NOTES  
Logout  
Command Name  
Description  
Syntax  
logout  
Log out of console interface  
logout  
Parameters  
Examples  
NOTES  
None  
N-TRON/Admin> logout  
(Revised 2010-11-15)  
Page 125 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CLI Commands, Continued…  
Show, Add, or Delete ARL Entries  
Command Name  
Description  
Syntax  
arl  
Show, Add, or Delete Arl Entries.  
arl show | showmct | add mac port cpu static vid | del[ete] mac vid  
Parameters  
show  
Show entire ARL table.  
showmct  
Show entire ARL MCT (Multicast Index) table.  
delete  
Delete MAC address.  
add  
Add MAC address.  
mac  
MAC Address.  
port  
Port Number.  
cpu  
1 = Send to CPU also.  
static  
1 = This is a static address; 0 = Non-Static.  
vid  
VLAN ID (0-4095)  
N-TRON/Admin> arl show  
Example  
No. Val Age Pri Mod Usr Sta VLAN  
MAC  
Port(s)  
---- --- --- --- --- --- --- ---- ----------------- ----------  
1 1 1 0 0 0 1  
2 1 0 0 0 0 0  
1 00:07:af:ff:b8:00 CPU  
1 00:19:b9:03:aa:77 TX3  
N-TRON/Admin> arl showmct  
No. Idx Val Port Mask Port(s)  
--- --- --- ---------- ----------  
1 0 1 0x00000000 (None)  
2 1 1 0x00000001 TX1  
N-TRON/Admin> arl add 00:19:b9:03:aa:79 3 0 1 1  
N-TRON/Admin> arl del 00:19:b9:03:aa:79 1  
Notes  
(Revised 2010-11-15)  
Page 126 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CLI Commands, Continued…  
Save or Reset the Configuration Settings  
Command Name  
Description  
Syntax  
config  
Save or reset configuration settings  
config s[ave] | r[eset]  
Parameters  
save  
save current running configuration settings.  
reset  
reset configuration settings to factory defaults.  
N-TRON/Admin> config save  
Examples  
Save Settings...  
Writing 'B:\settings\settings.dat'.  
Settings have been saved.  
N-TRON/Admin> config reset  
Resetting to factory defaults...  
Load factory default settings [y/n]?y  
Keep IP, subnet mask, and gateway addresses [y/n]?y  
Keep current user names and passwords [y/n]?y  
Keep current SNMP settings [y/n]?y  
Keep current DHCP Server settings [y/n]?y  
Keep current MAC Security settings [y/n]?y  
*** Model Number Changed ***: Forcing reset of settings values.  
***  
***  
Expected (per HW) = 0x87080000,  
Found (Saved) = 0x00000000,  
WARNING: Settings will be reset to factory default values.  
Writing 'B:\settings\settings.dat'.  
Done. You should now reset the device.  
N-TRON/Admin>  
NOTES  
(Revised 2010-11-15)  
Page 127 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Device Operations  
Command Name  
Description  
Syntax  
Parameters  
cfgdev  
Info, Format, Compare and Erase Configuration Device.  
CfgDev info | format [-m model] | compare | erase  
Info  
Show information about the configuration device.  
Compare  
Compare the configuration of the switch to the configuration device.  
Erase  
Erase the switch configuration on the configuration device.  
N-TRON/Admin> cfgdev info  
Example  
Port A:  
0xb0c0  
Board ID: 0x0006 (6)  
Configuration device information:  
Name  
Model  
: At64Kb  
: 2  
Version  
Page Size  
Total Size  
: 1  
: 128  
: 65536  
Max Clock (Hz) : 1000000  
Write Cycles (ns): 5000000  
Flags  
: 0x00000001  
N-TRON/Admin>  
N-TRON/Factory> cfgdev compare  
Comparing switch configuration to the configuration device...  
The configurations are different.  
N-TRON/Factory> cfgdev erase  
Erasing configuration device...  
Configuration device erase completed.  
Notes  
(Revised 2010-11-15)  
Page 128 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Show or Set CIP Configuration  
Command Name  
Cip  
Description  
Show or set CIP configuration. If no parameters are specified, this command will show  
the CIP configuration (same as -show parameter).  
Syntax  
-Cip [-e[nable] | -d[isable] | -show]  
Parameters  
-Cip -show  
Show CIP configuration.  
-Cip [-e[nable] | -d[isable]]  
Set the CIP status to e(nabled) or d(isabled).  
N-TRON/Admin> cip -show  
Examples  
CIP Configuration:  
------------------  
Status:  
EthIp Interval:  
Cache Interval:  
Enabled  
10 ms  
2000 ms  
Identity Information:  
---------------------  
Product Name:  
N-TRON 708M12  
Vendor:  
1006 (N-TRON)  
Device Type:  
0x0C (Communications Adapter)  
Major Revision:  
Minor Revision:  
Serial Number:  
1
2
0xAFFBE400  
Connection Information:  
-----------------------  
Multicast Connections: 0  
Unicast Connections:  
0
N-TRON/Admin> cip -disable  
Changing CIP configuration...  
CIP Configuration:  
------------------  
Status:  
Disabled  
EthIp Interval:  
Cache Interval:  
10 ms  
2000 ms  
Identity Information:  
---------------------  
Product Name:  
N-TRON 708M12  
Vendor:  
1006 (N-TRON)  
Device Type:  
0x0C (Communications Adapter)  
Major Revision:  
Minor Revision:  
Serial Number:  
1
2
0xAFFBE400  
Connection Information:  
-----------------------  
Multicast Connections: 0  
Unicast Connections:  
0
Changes have been made that have not been saved.  
N-TRON/Admin>  
NOTES  
(Revised 2010-11-15)  
Page 129 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Show or Set IGMP Configuration  
Command Name  
Description  
igmp  
Show or set IGMP configuration. If no parameters are specified, this command will show  
the IGMP configuration (same as -show parameter).  
Igmp [-show] [-status state]  
-show  
Syntax  
Parameters  
Show configuration.  
-status state  
Set the IGMP status to e(nabled) or d(isabled).  
N-TRON/Admin> igmp -show  
Examples  
IGMP Status  
IGMP Version  
Query Mode  
: Enabled  
: 2  
: Auto  
CIP Querier Status  
Active Querier IP  
Router Mode  
: 2, Active-Auto  
: 192.168.2.214  
: Auto  
Manual Router Ports : (None)  
IGMP Number of Groups : 1  
IGMP Resource Usage % : 1  
Changes have been made that have not been saved.  
N-TRON/Admin> igmp -status disabled  
IGMP Status  
IGMP Version  
Query Mode  
: Disabled  
: 2  
: Auto  
CIP Querier Status  
Active Querier IP  
Router Mode  
: 2, Active-Auto  
: 0.0.0.0  
: Auto  
Manual Router Ports : (None)  
IGMP Number of Groups : 0  
IGMP Resource Usage % : 0  
Changes have been made that have not been saved.  
N-TRON/Admin>  
NOTES  
(Revised 2010-11-15)  
Page 130 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CLI Commands, Continued…  
Show or Set Mirror Configuration  
Command Name  
Description  
Mirror  
Show or set Mirror configuration. If no parameters are specified, this command will  
show the Mirror configuration (same as -show parameter).  
Syntax  
mirror [-show] [-status state] [-dp portno] [-tx portlist] [-rx portlist]  
Parameters  
-show  
Show configuration.  
-status state  
Set the Mirror status to e(nabled) or d(isabled).  
-dp portno  
Set the destination port number for mirrored frames.  
-tx portlist  
Set the source ports to mirror frames that are transmitted.  
-rx portlist  
Set the source ports to mirror frames that are received.  
N-TRON/Admin> mirror show  
Examples  
Mirror Status  
: Disabled  
Destination Port : TX1  
Tx Source Ports : (None)  
Rx Source Ports : (None)  
N-TRON/Admin> mirror status enabled dp 6 tx 1,3-5 rx 1,3,5  
Mirror Status  
: Enabled  
Destination Port : TX6  
Tx Source Ports : TX1, TX3-TX5  
Rx Source Ports : TX1, TX3, TX5  
Changes have been made that have not been saved.  
NOTES  
The portlist consists of port numbers and ranges, separated by commas. It may not  
contain space characters. Use ―all‖ to set all ports as source ports, and use ―none‖ to clear  
all ports from source ports.  
(Revised 2010-11-15)  
Page 131 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CLI Commands, Continued…  
Show or Set N-Ring Configuration  
Command Name  
Description  
Nring  
Show or set N-Ring configuration. If no parameters are specified, this command will  
show the N-Ring configuration (same as -show parameter).  
nring [-show] [-mode d | a | m] [-ports set_id]  
-show  
Syntax  
Parameters  
Show configuration.  
-mode  
Set the N-Ring mode.  
d = disabled, a = auto member, m = manager  
-ports set_id  
Set the ring ports for N-Ring manager mode.  
Specify port set identifier or use ‗?‘ to list available port sets.  
N-TRON/Admin> nring show  
Examples  
N-Ring Mode : Auto Member  
Aging Time : 20  
N-TRON/Admin> nring ports ?  
ID  
--  
1
Port Set  
--------  
TX1 / TX2  
TX7 / TX8  
2
N-TRON/Admin> nring mode m ports 2  
Do you Want to Save Changes and Restart the System Now [y/n]?  
NOTES  
Show or Set N-View Configuration  
Command Name  
Description  
Nview  
Show or set N-View configuration. If no parameters are specified, this command will  
show the N-View configuration (same as -show parameter).  
Syntax  
nview [-show] [-status state]  
Parameters  
-show  
Show configuration.  
-status state  
Set the N-View status to e(nabled) or d(isabled).  
N-TRON/Admin> nview show  
Examples  
N-View Status : Enabled  
N-View Interval : 5  
N-TRON/Admin> nview status disabled  
N-View Status : Disabled  
N-View Interval : 5  
Changes have been made that have not been saved.  
NOTES  
(Revised 2010-11-15)  
Page 132 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CLI Commands, Continued…  
Ping a Host  
Command Name  
Description  
Syntax  
Ping  
Ping a host  
ping [-t] [-n count] [-w timeout] target_name  
Parameters  
target_name  
IP Address or host name.  
-t  
Ping the specified host until stopped.  
To see statistics and continue - type Space;  
To stop - type Control-C.  
-n count  
Number of echo requests to send.  
-w timeout  
Timeout in milliseconds to wait for each reply.  
N-TRON/Admin> ping 192.168.1.119  
Example  
N-TRON/Admin> ping n 6 192.168.1.119  
N-TRON/Admin> ping t 192.168.1.119  
N-TRON/Admin> ping w 2000 192.168.1.119  
Reply from 192.168.1.119: time=970ms  
Reply from 192.168.1.119: time<10ms  
Reply from 192.168.1.119: time<10ms  
Ping statistics for 192.168.1.119:  
Packets: Sent = 4, Received = 3, Lost = 1 (25% loss)  
Approximate round trip times in milliseconds:  
Minimum = 0ms, Maximum = 970ms, Average = 320ms  
Notes  
(Revised 2010-11-15)  
Page 133 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CLI Commands, Continued…  
Show or Set Port Configuration  
Command  
Name  
Port  
Description  
Syntax  
Show or set Port configuration.  
Port [-show] [-admin state] [-sd auto | 10h | 10f | 100h | 100f | 1000f] [-flow state][-fhp state][-dp prio] [-dscp state]  
[-8021p state] [-pvid vid] [-ual percent][-uah percent] [-security state] portno  
Parameters  
portno  
Port number to configure or show. Specify ―all‖ to show all ports.  
-show  
Show configuration.  
-admin state  
Set the admin status for the port to e(nabled) or d(isabled).  
-sd  
Set the speed and duplex mode for the port. auto = enable auto-negotiation  
-flow state  
Set the flow control for the port to e(nabled) or d(isabled).  
-fhp state  
Set force high priority for the port to e(nabled) or d(isabled).  
-dp prio  
Set the default QOS priority for the port. The range is 0-7.  
-dscp  
Include DSCP Priority for the port.  
-8021p  
Include 802.1p Priority for the port.  
-pvid vid  
Set the VLAN ID for the port. The range is 1-4094.  
-ual percent  
Set the usage alarm low percentage. The range is 0-100.  
-uah percent  
Set the usage alarm high percentage. The range is 0-100.  
-security  
Set the security status for all supported ports.  
N-TRON/Admin> port -sd 100f -flow enabled -dp 7 -pvid 2 5  
Examples  
Usage Usage  
Port Port Admin  
No Name Status Stat  
Link  
Auto  
Nego  
Port Dupl Flow  
Spd Mode Control High Pri  
Force  
Include Include Def  
DSCP 802.1p Pri  
Port  
State  
Alarm Alarm Security  
PVID Low % High % Status  
---- ---- -------- ---- -------- ---- ---- -------- -------- -------- -------- --- ---------- ---- ----- ------ --------  
5 TX5 Enabled Up Disabled 100 Full Enabled Disabled Enabled Enabled 7 Forwarding 100 Disabled  
2
0
Changes have been made that have not been saved.  
N-TRON/Admin>  
NOTES  
Reset the Switch  
Command Name  
Description  
Syntax  
Reset  
Reset (reboot) the switch  
Reset  
Parameters  
Example  
None  
N-TRON/Admin> reset  
Preparing for reset.  
Cleaning up...  
Browser will be redirected to 192.168.2.214.  
Disabling SNMP...  
Disabling DHCP...  
Disabling CIP...  
Locking out other processes...  
Disable preemption...  
Resetting device...  
Notes  
(Revised 2010-11-15)  
Page 134 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CLI Commands, Continued…  
Show or Set SNMP Configuration  
Command Name  
Description  
Snmp  
Show or set SNMP configuration. If no parameters are specified, this command will  
show the SNMP configuration (same as -show parameter).  
Syntax  
snmp [-show] [-ro name] [-rw name] [-trap name]  
Parameters  
-show  
Show configuration.  
-ro name  
Set the Authorized Community Name for SNMP Get requests.  
-rw name  
Set the Authorized Community Name for SNMP Set requests.  
-trap name  
Set the Authorized Community Name for SNMP Traps.  
N-TRON/Admin> snmp ro users  
Examples  
IP Address - Trap Stn.#1 : Value Not Configured  
IP Address - Trap Stn.#2 : Value Not Configured  
IP Address - Trap Stn.#3 : Value Not Configured  
IP Address - Trap Stn.#4 : Value Not Configured  
IP Address - Trap Stn.#5 : Value Not Configured  
Read-Only Community Name : users  
Read-Write Community Name : private  
Trap Community Name  
: public  
Changes have been made that have not been saved.  
NOTES  
Community names may only contain alphanumeric, space, ‗-‗, ‗_‘, and ‗#‘ characters,  
and may not begin with a number, space, or underscore. A name with embedded space  
characters must be enclosed in quotes. The maximum length is 15 characters.  
Show or Clear the Last System Error  
Command Name  
Description  
Syserr  
Show or clear the last system error  
If clear is not supplied, then the last system error is displayed.  
Syntax  
syserr [clear]  
Parameters  
Clear  
Clear the last system error.  
N-TRON/Admin> syserr  
Last System Error: None.  
Example  
N-TRON/Admin> syserr clear  
Last System Error: Cleared.  
Notes  
(Revised 2010-11-15)  
Page 135 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CLI Commands, Continued…  
Show System Information  
Command Name  
Description  
Syntax  
Sysinfo  
Show system information  
Sysinfo  
Parameters  
Example  
None  
N-TRON/Admin> Sysinfo  
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++  
+
+ N-TRON 700/7000/7500 Series  
+
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++  
+
+ Model:  
708M12  
+ Boot Loader: BL 2.0.5.1 (0x02000501)  
+ OS Version: 3.4.2  
+ Build Date: Jun 17 2010 at 16:31:37  
+ Copyright:  
reserved.  
+
Copyright (c) 2008-2010 N-TRON Corp. All rights  
+ Processor:  
66 MHz (66000000)  
+ SDRAM Size: 16 MB  
+ Flash Size: 8 MB  
+ File System: 6422528 Bytes, 348160 Free, 6074368 Used, 0 Bad  
+ MAC Address: 00:07:af:fb:e4:00  
+ IP Address: 192.168.2.214  
+ Subnet Mask: 255.255.255.0  
+ Gateway:  
192.168.1.9  
+ Cfg Device: At64Kb  
+
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++  
N-TRON/Admin>  
Notes  
(Revised 2010-11-15)  
Page 136 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CLI Commands, Continued…  
Set or Show the System IP Configuration  
Command Name  
Description  
Sysip  
Set system IP configuration mode, IP address, subnet mask, and gateway  
If no parameters are specified, this command will show the system IP addresses. Static  
IP, subnet mask, or gateway can be set while in either DHCP or static configuration  
mode as they will be used with IP fallback when in DHCP mode. If the Static IP is set to  
the default system IP address, IP fallback will not occur. All system addresses must be  
formatted as: xxx.xxx.xxx.xxx.  
Syntax  
sysip [-c config_mode] [-i static_ip] [-s static_subnet_mask] [-g static_gateway]  
Parameters  
-c config_mode  
s(tatic) or d(hcp).  
-i static_ip  
Static IP address (for static config mode and IP fallback ).  
-s static_subnet_mask  
Static sub net mask (for static config mode and IP fallback ).  
-g static_gateway  
Static gateway address ( for static config mode and IP fallback ).  
N-TRON/Admin> sysip  
Example  
IP Configuration Mode : Static  
Static IP Address  
Static subnet Mask  
Static gateway  
: 192.168.1.225  
: 255.255.255.0  
: 192.168.1.1  
N-TRON/Admin> sysip -c dhcp  
IP Configuration Mode : DHCP (has been changed)  
Fallback IP Address : 192.168.1.225  
Fallback Subnet Mask : 255.255.255.0  
Fallback Gateway  
: 192.168.1.1  
Press <ENTER> to Save Changes and Restart the System Now  
N-TRON/Admin> sysip -i 192.168.2.119 -s 255.255.252.0 -g  
192.168.1.1  
IP Configuration Mode : Static  
Static IP Address  
Static Subnet Mask  
Static Gateway  
: 192.168.2.119 (has been changed)  
: 255.255.252.0 (has been changed)  
: 192.168.1.1 (has been changed)  
Press <ENTER> to Save Changes and Restart the System Now  
NOTES  
If mode is set to DHCP and IP fallback occurs, DHCP requests will stop.  
If mode is set to DHCP and IP Configuration is retrieved from a DHCP server, IP  
fallback will not occur, even if lease is lost.  
(Revised 2010-11-15)  
Page 137 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CLI Commands, Continued…  
Show or Set System Configuration  
Command Name  
Description  
System  
Show or set System configuration. If no parameters are specified, this command will  
show the System configuration (same as -show parameter).  
Syntax  
system [-show] [-name label] [-browser state]  
Parameters  
-show  
Show configuration.  
-name label  
Set the switch name.  
-browser state  
Set the browser access status to e(nabled) or d(isabled).  
N-TRON/Admin> system -name "Private Switch" -browser disabled  
Examples  
IP Configuration : Static  
Client ID (hex) : 0007affbe400  
IP Address  
Subnet Mask  
Gateway  
: 192.168.2.214  
: 255.255.255.0  
: 192.168.1.9  
MAC Address  
: 00:07:af:fb:e4:00  
System Up Time : 0 days, 0 hours, 17 mins, 2 secs  
Name  
Contact  
Location  
: Private Switch  
: N-TRON Admin  
: Mobile, AL 36609  
Browser Access : Disabled  
Changes have been made that have not been saved.  
N-TRON/Admin>  
NOTES  
A switch name may only contain alphanumeric, space, ‗:‘, ‗-‗, ‗_‘, and ‗#‘ characters, and  
may not begin with a number, space, or underscore. A name with embedded space  
characters must be enclosed in quotes.  
(Revised 2010-11-15)  
Page 138 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Addition and Deletion Example  
The screen capture below is the factory default VLAN configuration.  
Clicking on the ―Modify‖ button allows one to add a new VLAN:  
(Revised 2010-11-15)  
Page 139 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
When creating a new VLAN, a numeric ID is required, Name is entered. Note that N-Ring VLAN is a  
reserved name with a special meaning. Choices such as ―Allow Management‖ and ―Change PVID of  
Member Ports‖ are made at this time as well as the ports which are going to belong to the new VLAN.  
Additionally, the ports may be ―Untagged on Egress‖.  
(Revised 2010-11-15)  
Page 140 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The result of add is a ―New VLAN‖. In this case, it does not overlap the ―Default VLAN‖ ports.  
(Revised 2010-11-15)  
Page 141 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The ports of ‖New VLAN‖ may be added back to ―Default VLAN‖ to create overlapping VLANs.  
Note: If there are multiple ports on different VLANs, the 708 will apply the static multicast address to the  
lowest VLAN-ID that is associated with one of the ports assigned to the static multicast address. If the  
lowest VLAN-ID contains all the ports assigned to the static multicast address (an umbrella VLAN), it will  
function for all those ports with no problems. This can be achieved with overlapping VLANs.  
But notice that the ports in ―New VLAN‖ are not marked as ―Untag on Egress‖ and are thus still tagged.  
And the ―New VLAN‖ may be deleted when it is no longer required:  
(Revised 2010-11-15)  
Page 142 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(Revised 2010-11-15)  
Page 143 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
And the ―New VLAN‖ is removed. Note that the new configuration of the switch must be saved if the  
configuration must survive a power cycle.  
(Revised 2010-11-15)  
Page 144 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN Configuration Examples  
A VLAN is an administratively configured LAN segment that limits the traffic in multiple broadcast domains. Instead of  
physically reconnecting a device to a different LAN, network administrators can accomplish this task by configuring a  
VLAN compliant switch to create logical network segments.  
Tagged VLAN allows switch segmentation to span across multiple managed switches. This type of VLAN is ideal for  
LANs that consist of various types of communication groups such as Office LANs, Controls Systems, and IP  
Cameras. When used properly, it will effectively isolate two or more groups from each other in a logical manner. This  
means that Broadcast, Multicast, and Unicast frames in one VLAN will not interfere with another isolated VLAN group.  
Example 1 Basic understanding of port-based VLANs  
Receiving  
Port #  
Tagged VID  
in packet  
Destination  
Address  
Transmitting  
Port #s  
Notes  
TX1  
Untagged  
Untagged  
VID 4  
Untagged  
Untagged  
VID 4  
MAC on port TX2  
TX2  
TX2  
--  
TX5  
TX4-TX8  
--  
Unicast Traffic  
Floods VLAN 2  
Packet Discarded  
Unicast Traffic  
Floods VLAN 1  
Packet Discarded  
TX1  
TX1  
TX3  
TX3  
TX3  
Unknown MAC  
MAC on port TX2  
MAC on port TX5  
Unknown MAC  
MAC on port TX6  
(Revised 2010-11-15)  
Page 145 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Example 2 Basic understanding of tagged VLANs (Admit Tagged Only)  
Receiving  
Port #  
TX1  
Tagged VID  
in packet  
Untagged  
Destination  
Address  
MAC on port TX2  
Transmitting  
Port #s  
--  
Notes  
Packet Discarded  
Unicast Traffic  
Packet Discarded  
Floods VLAN 2  
Packet Discarded  
Unicast Traffic  
Floods VLAN 1  
Packet Discarded  
TX1  
TX1  
TX1  
TX3  
TX3  
TX3  
TX3  
VID 2  
VID 4  
VID 2  
Untagged  
VID 1  
VID 1  
VID 4  
MAC on port TX2  
MAC on port TX2  
MAC on port TX5  
MAC on port TX1  
MAC on port TX6  
Unknown MAC  
TX2  
--  
TX2  
--  
TX6  
TX5-TX8  
--  
MAC on port TX8  
(Revised 2010-11-15)  
Page 146 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Example 3 Basic understanding of tagged VLANs (Admit All)  
Receiving  
Port #  
Tagged VID  
in packet  
Destination  
Address  
Transmitting  
Port #s  
Notes  
TX1  
Untagged  
MAC on port TX2  
TX2  
TX2  
--  
TX2  
TX4-TX8  
TX6  
TX4-TX8  
--  
Adds VID 2 to packet  
Unicast Traffic  
Packet Discarded  
Floods VLAN 2  
Adds VID 1 to packet & Floods VLAN 1  
Unicast Traffic  
TX1  
TX1  
TX1  
TX3  
TX3  
TX3  
TX3  
VID 2  
VID 4  
VID 2  
Untagged  
VID 1  
VID 1  
VID 4  
MAC on port TX2  
MAC on port TX2  
Unknown MAC  
Unknown MAC  
MAC on port TX6  
Unknown MAC  
MAC on port TX7  
Floods VLAN 1  
Packet Discarded  
(Revised 2010-11-15)  
Page 147 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Example 4 Basic understanding of Hybrid VLANs  
Receiving  
Port #  
Tagged VID  
in packet  
Destination  
Address  
Transmitting  
Port #s  
Notes  
TX1  
Untagged  
MAC on port TX2  
TX2  
Unicast Traffic  
TX1  
TX1  
TX1  
TX1  
TX3  
TX3  
TX3  
TX3  
TX3  
TX3  
Untagged  
VID 4  
VID 4  
MAC on port TX3  
MAC on port TX2  
MAC on port TX3  
MAC on port TX2  
MAC on port TX6  
Unknown MAC  
MAC on port TX5  
MAC on port TX4  
MAC on port TX4  
MAC on port TX1  
TX3  
--  
--  
TX2  
TX6  
TX4-TX8  
--  
--  
TX4  
TX1  
Adds VID 2 in the packet  
Packet Discarded  
Packet Discarded  
Strips VID off packet  
Unicast Traffic  
Floods VLAN 1  
Packet Discarded  
Packet Discarded  
Does not strip VID off packet  
Strips VID off packet  
VID 2  
Untagged  
Untagged  
VID 4  
VID 4  
VID 2  
VID 2  
(Revised 2010-11-15)  
Page 148 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Example 5 Basic understanding of Overlapping VLANs  
Receiving  
Port #  
Tagged VID  
in packet  
Destination  
Address  
Transmitting  
Port #s  
Notes  
TX1  
Untagged  
MAC on port TX2, TX2  
VID=4  
Unicast Traffic  
TX1  
TX1  
Untagged  
VID 4  
MAC on port TX3  
MAC on port TX2, TX2  
VID=4  
TX2  
Floods VLAN 4  
Strips VID off packet  
TX1  
TX2  
VID 4  
Untagged  
Unknown MAC  
MAC on port TX1, TX1  
VID=2  
TX2  
Strips VID off packet & Floods VLAN 4  
Unicast Traffic  
TX2  
TX2  
Untagged  
MAC on port TX5, TX5  
VID=2  
MAC on port TX5, TX5  
VID=2 and 3  
Unicast Traffic  
VID 2 or 3  
Strips VID off packet (or floods if MAC  
is unknown for VID)  
TX2  
TX3  
Untagged  
Untagged  
Unknown MAC  
MAC on port TX1, TX2, TX4-TX8 Floods VLAN 3  
VID=3  
TX1, TX3-TX8 Floods VLAN 2  
TX3  
TX3  
TX3  
Untagged  
Untagged  
VID 2 or 3  
MAC on port TX2, TX2  
VID=3  
MAC on port TX5, TX5  
VID=3  
MAC on port TX2, TX2  
VID=2 and 3  
Unicast Traffic  
Unicast Traffic  
Strips VID off packet (or floods if MAC  
is unknown for VID)  
(Revised 2010-11-15)  
Page 149 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Example 6 Basic understanding of VLANs with Multicast Filtering  
Top of Form  
Bottom of Form  
Receiving  
Port #  
Tagged VID  
in packet  
Destination  
Address  
Transmitting  
Port #s  
Notes  
Goes to ports TX1-TX8, but TX1 can only  
send to TX2 (VLAN 4)  
Goes to ports TX2, TX6-TX8 (VLAN 3) but  
filter keeps it on ports TX6 and TX8 only  
Goes to ports TX1-TX8, but won‘t go back  
out the port it came in on  
TX1  
TX3  
TX2  
Untagged  
Untagged  
Untagged  
01:00:00:00:00:01 TX2  
01:00:00:00:00:02 TX6, TX8  
01:00:00:00:00:01 TX1,TX3-TX8  
TX2  
TX3  
TX6  
TX3  
Untagged  
Untagged  
Untagged  
Untagged  
01:00:00:00:00:02 TX1,TX3-TX8  
01:00:00:00:00:01 TX2, TX4-TX8  
01:00:00:00:00:02 TX8  
Goes to ports TX1,TX3-TX8  
Goes to ports TX2, TX4-TX8  
Goes to port TX8  
01:00:00:00:00:02 TX6, TX8  
Goes to ports TX6 and TX8  
Note: If there are multiple ports on different VLANs, the 708 will apply the static multicast address to the  
lowest VLAN-ID that is associated with one of the ports assigned to the static multicast address. If the  
lowest VLAN-ID contains all the ports assigned to the static multicast address (an umbrella VLAN), it will  
function for all those ports with no problems. This can be achieved with overlapping VLANs.  
For further information and examples on overlapping vlans, see:  
http://www.n-tron.com/pdf/OverlappingPortVLAN.pdf  
(Revised 2010-11-15)  
Page 150 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
KEY SPECIFICATION  
Switch Properties  
Number of MAC Addresses:  
Aging Time:  
Latency Type:  
8,000  
Programmable  
2.9 µs  
Switching Method:  
Store & Forward  
Physical  
Height:  
Width:  
Depth:  
Weight:  
DIN Rail  
6.7‖ (16.9 cm)  
6.7‖ (16.9 cm)  
1.8‖ (4.6 cm)  
3.4 lbs. (1.6 kg)  
35 mm (Optional)  
Electrical  
Redundant Input Voltage:  
High Voltage:  
10-30VDC (Regulated)  
40-160VDC (Regulated)  
708M12 Input Current (max):  
Inrush @ 24VDC:  
250mA max. @ 24VDC  
15.0A/1.0ms @ 24VDC  
Input Ripple:  
Less than 100 mV  
N-TRON Power Supply:  
NTPS-24-1.3 (1.3 Amp@24VDC) (NOTE: Not appropriate for use with  
M12, POE, and HV models.)  
Connectors  
Environmental  
10/100BaseTX: (8) M12 D Coded Female Copper Ports  
POWER:  
COM:  
NTCD-M12:  
(1) M12 A Coded Male Port  
(1) M12 A Coded Female CLI Port  
(1) M12 A Coded Female Configuration configuration device Port  
Operating Temperature: -40°C to 80°C  
Storage Temperature: -40°C to 85°C  
Operating Humidity: 5% to 100%  
(Non Condensing)  
Recommended Wiring Clearance:  
Front: 4" (10.16 cm)  
Operating Altitude 0 to 10,000 ft.  
Network Media  
Shock and Vibration  
(bulkhead mounting)  
10BaseT:  
>Cat3 Cable  
100BaseTX:  
>Cat5 Cable  
minimum length : 1 meter  
maximum length : 100 meters  
Shock:  
200g @ 10ms  
Vibration/Seismic: 50g, 5-200Hz,Triaxial  
Reliability  
MTBF: >2 Million Hours  
Pin Assignments  
Warranty: 3 years from the date of purchase.  
(Revised 2010-11-15)  
Page 151 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Regulatory Approvals:  
Safety: UL Listed per ANSI/ISA-12.12.01-2007 (US and Canada)  
This equipment is suitable for use in Class I, Div 2, Groups A, B, C, D,  
or non-hazardous locations, T4A  
The high voltage model is TÜV approved GS per EN 60950-1.  
EMI: EN61000-6-4, EN55011 Class A  
CFR Title 47, Part 15, Subpart B - Class A  
ICES-003 Class A  
EMS: EN61000-6-2  
EN61000-4-2 (ESD)  
EN61000-4-3 (RS)  
EN61000-4-4 (EFT)  
EN61000-4-5 (Surge)  
EN61000-4-6 (Conducted Disturbances)  
IEC 61000-4-8 (Power-frequency Magnetic Field)  
IEC 61000-4-11 (Voltage Dips and Interruptions)  
(Revised 2010-11-15)  
Page 152 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A. XML Settings File Example  
<!-- Overview of XML settings for N-TRON switches -->  
<!-- XML settings can be downloaded to a switch to configure the switch. XML settings cover a  
subset of the settings available through a web browser. -->  
<!-- There are several top level configuration sections. Each section is optional.  
<SystemConfiguration>  
<Switches/>  
<Administration/>  
<IPConfiguration/>  
<Users/>  
<Ports/>  
<DHCPServer/>  
<MACSecurity/>  
</SystemConfiguration>  
-->  
<SystemConfiguration version="1" minSwVer="3.4.2">  
<!-- The minSwVer attribute is optional. If present, the XML settings are ignored if the  
switch software version does not meet the minimum version requirement -->  
<!-- ______________________________________________________________________________________ -->  
<!-- The Switches block is optional. If present, the model name of the target switch must  
be in the list for the file to be processed. -->  
<Switches>  
<Switch minSwVer="3.2.10">708TX</Switch> <!-- If the minSwVer attribute is present, it  
overrides the minSwVer attribute of  
SystemConfiguration. -->  
<Switch>7506GX2</Switch>  
</Switches>  
<!-- ______________________________________________________________________________________ -->  
<!-- Administration -->  
<Administration>  
<SwitchName>myname</SwitchName>  
<!-- optional --><!--255 character limit-->  
<SwitchLocation>mylocation</SwitchLocation><!-- optional --><!--255 character limit-->  
<SwitchContact>mycontact</SwitchContact> <!-- optional --><!--255 character limit-->  
</Administration>  
<!-- ______________________________________________________________________________________ -->  
<!-- IP configuration -->  
<IPConfiguration>  
<Mode>static OR dhcp</Mode> <!-- Mode must be static or dhcp -->  
<!-- If dhcp mode, these elements are the "Fallback" Address, Subnet, and Gateway.  
Note: For an IP address of 192.168.1.201, there is no fallback address. -->  
<!-- All IP addresses have a 15 character limit (xxx.xxx.xxx.xxx) -->  
<Address>192.168.1.222</Address>  
<Subnet>255.255.255.0</Subnet>  
<Gateway>192.168.1.1</Gateway>  
<!-- 15 character limit -->  
<!-- 15 character limit -->  
<!-- 15 character limit -->  
<!-- If dhcp mode, this is the dhcp client id -->  
<ClientID>  
<!-- Use one of the elements (MACAddress, SwitchName, OtherText, OtherHex).  
MACAddress and SwitchName use current switch values. -->  
<MACAddress/>  
<SwitchName/>  
<OtherText>myClientID</OtherText>  
<!-- 255 character limit -->  
Page 153 of 156  
(Revised 2010-11-15)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
<OtherHex>0102de03ad00be09ef</OtherHex> <!-- 255*2 character limit -->  
</ClientID>  
</IPConfiguration>  
<!-- ______________________________________________________________________________________ -->  
<!-- User management -->  
<!-- A list of logon accounts (5 maximum) to add to the switch. -->  
<Users mode="keep or delete">  
<!-- mode must be "keep" or "delete" -->  
<!-- mode=delete - delete existing accounts before adding accounts (default) -->  
<!-- mode=keep - do not delete existing accounts before adding accounts -->  
<!-- All User elements (name, password, access) are required. -->  
<User>  
<Name>Joe</Name>  
<Password>xxx</Password>  
<Access>admin OR user</Access>  
<!-- 3-15 character limit -->  
<!-- 3-15 character limit -->  
<!-- Access must be admin or user -->  
</User>  
</Users>  
<!-- ______________________________________________________________________________________ -->  
<!-- Port configuration -->  
<!-- You may uses this block to define port VLAN identifiers (PVIDs) -->  
<Ports>  
<ValidatePorts>yes OR no</ValidatePorts> <!-- optional --> <!-- Must be yes(default)  
or no. If no, invalid ports are ignored. -->  
<!-- Use PortNumber or PortName -->  
<Port>  
<PortNumber>4</PortNumber> <!-- PortNumber ranges from 1 to the maximum port  
number for the switch -->  
<PVID>1</PVID>  
</Port>  
<Port>  
<PortName>TX6</PortName> <!-- Name of port on switch -->  
<PVID>26</PVID> <!-- PVID ranges from 1 to 4094 -->  
</Port>  
</Ports>  
<!-- PVID ranges from 1 to 4094 -->  
<!-- ______________________________________________________________________________________ -->  
<!-- DHCP server -->  
<DHCPServer mode="keep or delete">  
<!-- mode must be "keep" or "delete" -->  
<!-- mode=delete - delete existing profiles before adding profiles (default) -->  
<!-- mode=keep - do not delete existing profiles before adding profiles -->  
<Enabled>yes OR no</Enabled>  
<!-- Enabled must be yes or no -->  
<!-- If the server is enabled (enabled=yes), you can add DHCP server profiles.  
(If not enabled, can not add profiles.) -->  
<Profile>  
<!-- Required: Name, LowIP, HighIP, LeaseDays. LeaseHours is optional, and  
defaults to 0. -->  
<Name>prof1</Name>  
<LowIP>192.168.2.1</LowIP>  
<!-- required --> <!-- 19 character limit -->  
<!-- required -->  
<HighIP>192.168.2.254</HighIP> <!-- required -->  
<LeaseDays>28</LeaseDays>  
<LeaseHours>0</LeaseHours>  
<!-- required -->  
<!-- optional -->  
<!--The Advanced block is optional, and all elements within the block are  
optional.-->  
<Advanced>  
<!-- optional -->  
<!-- All elements below are optional -->  
<BroadcastAddress>192.168.2.255</BroadcastAddress>  
(Revised 2010-11-15)  
Page 154 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
<DomainName>N-TRON.com</DomainName>  
<DNSServer1>192.168.2.10</DNSServer1>  
<DNSServer2>192.168.2.11</DNSServer2>  
<Gateway1>192.168.2.1</Gateway1>  
<Gateway2>192.168.2.2</Gateway2>  
<!-- 63 character limit -->  
</Advanced>  
<IPMaps>  
<!-- The DynamicRange is the only IP Map supported. You may have 0 or more. -->  
<DynamicRange>  
<!-- low and high within range of profile -->  
<LowIP>192.168.2.1</LowIP>  
<HighIP>192.168.2.4</HighIP>  
<!-- required -->  
<!-- required -->  
</DynamicRange>  
</IPMaps>  
</Profile>  
</DHCPServer>  
<!-- ______________________________________________________________________________________ -->  
<!-- MAC security -->  
<MACSecurity>  
<Mode>learning OR locked</Mode>  
<!-- Mode must be learning or locked -->  
<!-- mode must be "keep" or "delete" -->  
<!-- Authorized entries -->  
<Authorized mode="keep or delete">  
<!-- mode=delete - delete existing authorized MACs before adding  
authorized MACs (default) -->  
<!-- mode=keep - do not delete existing authorized MACs before  
adding authorized MACs -->  
<ValidatePorts>yes OR no</ValidatePorts> <!-- optional -->  
<!-- Must be yes(default) or no.  
If no, invalid ports are ignored. -->  
<Entry>  
<MACAddress>00:07:af:ff:5b:c0</MACAddress>  
<!-- 17 character limit -->  
<!-- MAC is valid on all ports listed in the ports list.  
If the ports list is missing, then the MAC is valid on all ports. -->  
<Ports>  
<Port>  
<!-- Use PortNumber or PortName -->  
<PortNumber>4</PortNumber> <!-- 1 to maximum port for switch -->  
</Port>  
<Port>  
<PortName>TX5</PortName>  
</Port>  
</Ports>  
</Entry>  
<Entry>  
<!-- Name of port on switch -->  
<MACAddress>0007af1d6460</MACAddress> <!-- Example of a MAC with no  
delimiters, valid on all ports. -->  
</Entry>  
</Authorized>  
</MACSecurity>  
</SystemConfiguration>  
(Revised 2010-11-15)  
Page 155 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-TRON Limited Warranty  
N-TRON, Corp. warrants to the end user that this hardware product will be free from defects in workmanship and materials, under normal  
use and service, for the applicable warranty period from the date of purchase from N-TRON or its authorized reseller. If a product does not  
operate as warranted during the applicable warranty period, N-TRON shall, at its option and expense, repair the defective product or part,  
deliver to customer an equivalent product or part to replace the defective item, or refund to customer the purchase price paid for the  
defective product. All products that are replaced will become the property of N-TRON. Replacement products may be new or  
reconditioned. Any replaced or repaired product or part has a ninety (90) day warranty or the remainder of the initial warranty period,  
whichever is longer. N-TRON shall not be responsible for any custom software or firmware, configuration information, or memory data of  
customer contained in, stored on, or integrated with any products returned to N-TRON pursuant to any warranty.  
OBTAINING WARRANTY SERVICE: Customer must contact N-TRON within the applicable warranty period to obtain warranty service  
authorization. Dated proof of purchase from N-TRON or its authorized reseller may be required. Products returned to N-TRON must be  
pre-authorized by N-TRON with a Return Material Authorization (RMA) number marked on the outside of the package, and sent prepaid  
and packaged appropriately for safe shipment. Responsibility for loss or damage does not transfer to N-TRON until the returned item is  
received by N-TRON. The repaired or replaced item will be shipped to the customer, at N-TRON‘s expense, not later than thirty (30) days  
after N-TRON receives the product. N-TRON shall not be responsible for any software, firmware, information, or memory data of  
customer contained in, stored on, or integrated with any products returned to N-TRON for repair, whether under warranty or not.  
ADVANCE REPLACEMENT OPTION: Upon registration, this product qualifies for advance replacement. A replacement product will  
be shipped within three (3) days after verification by N-TRON that the product is considered defective. The shipment of advance  
replacement products is subject to local legal requirements and may not be available in all locations. When an advance replacement is  
provided and customer fails to return the original product to N-TRON within fifteen (15) days after shipment of the replacement, N-TRON  
will charge customer for the replacement product, at list price.  
WARRANTIES EXCLUSIVE: IF AN N-TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER'S SOLE  
REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE  
PRICE PAID, AT N-TRON'S OPTION. TO THE FULL EXTENT ALLOWED BY LAW, THE FOREGOING WARRANTIES AND  
REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR  
IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES,  
TERMS, OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY QUALITY,  
CORRESPONDENCE WITH DESCRIPTION, AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED. N-  
TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN  
CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. N-TRON SHALL NOT BE  
LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR  
MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER'S OR ANY THIRD PERSON'S  
MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY  
THE PRODUCT, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE,  
LIGHTNING, POWER CUTS OR OUTAGES, OTHER HAZARDS, OR ACTS OF GOD.  
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW, N-TRON ALSO EXCLUDES FOR ITSELF AND ITS  
SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL,  
CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR  
PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN  
CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF  
ITS PRODUCTS, EVEN IF N-TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT N-  
TRON'S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED  
HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.  
DISCLAIMER: Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the limitation of  
incidental or consequential damages for certain products supplied to consumers, or the limitation of liability for personal injury, so the  
above limitations and exclusions may be limited in their application to you. When the implied warranties are not allowed to be excluded in  
their entirety, they will be limited to the duration of the applicable written warranty. This warranty gives you specific legal rights which  
may vary depending on local law.  
GOVERNING LAW: This Limited Warranty shall be governed by the laws of the State of Delaware,  
U.S.A  
(Revised 2010-11-15)  
Page 156 of 156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Miele Vacuum Cleaner S 4000 Series User Manual
Multiquip Portable Generator DCA 400SSV User Manual
NEC Projector XT5000 User Manual
NHT Speaker Sc 2 User Manual
Nortel Networks IP Phone MCC 3100 User Manual
Onkyo Stereo System T 4355 User Manual
Oreck Home Security System S184 User Manual
Oregon Scientific Clock EB833 User Manual
Ozaki Worldwide Portable Speaker dotodot300 User Manual
Panasonic DVR HX DC3 User Manual