GSX13
Split SyStem
Air Conditioner
Cooling CApACity:
18,000 - 60,000 BtU/h
13 SEER / 1½ to 5 tonS
Standard Features
• R-410A chlorine-free refrigerant
• Energy-efficient compressor
• Factory-installed filter drier
• Copper tube/aluminum fin coil
• Service valves with sweat connections
and easy-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified
• ETL Listed
Cabinet Features
• Goodman® brand louvered sound control
top design
• Steel louver coil guard
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish
with 500-hour salt-spray approval
• Top and side maintenance access
• Single-panel access to controls with space provided
for field-installed accessories
• When properly anchored, meets the 2001 Florida
Building Code unit integrity requirements for
hurricane-type winds (Anchor bracket kits available.)
Contents
Nomenclature......................................................................2
Product Specifications .........................................................3
Expanded Cooling Data .......................................................4
AHRI Ratings.......................................................................22
Dimensions ........................................................................34
Wiring Diagrams ...............................................................35
Accessories .........................................................................39
*
Complete warranty details available from your local
Year Parts Limited Warranty, online registration must
be completed within 60 days of installation. Online
registration is not required in California or Quebec.
SS-GSX13
1/13
Supersedes 12/12
Product SPecificationS
SpeCifiCAtionS
GSX13
0181E*
GSX13
0241D*
GSX13
0301B*
GSX13
0361C*
GSX13
0361E*
GSX13
0421B*
GSX13
0481B*
GSX13
0601B*
GSX13
0611A*
Capacities
Nominal Cooling (BTU/h)
SEER / EER
18,000
13 / 11
75
24,000
13 / 11
75
30,000
13 / 11
73
36,000
13 / 11
74
36,000
13 / 11
74
42,000
13 / 11
75
48,000
13 / 11
76
60,000
13 / 11
77
60,000
13/11
72
Decibels
Compressor
RLA
6.7
41
13.5
58.3
12.8
64
14.1
77
14.1
77
17.9
112
19.9
109
25.0
134
26.4
134
LRA
Condenser Fan Motor
Horsepower
1/8
0.7
1/8
0.7
1/8
0.7
1/6
1.1
1/4
1.5
1/4
1.5
1/4
1.5
1/4
1.5
1/4
1.5
FLA
Refrigeration System
Refrigerant Line Size ¹
Liquid Line Size (“O.D.)
Sucꢀon Line Size (“O.D.)
Refrigerant Connecꢀon Size
Liquid Valve Size (“O.D.)
Sucꢀon Valve Size (“O.D.) ⁴ ⁵
Valve Type
⅜"
¾"
⅜"
¾"
⅜"
¾"
⅜"
⅞"
⅜"
⅞"
⅜"
⅜"
⅜"
⅜"
⅞"
1⅛"
1⅛"
1⅛"
⅜"
¾"
⅜"
¾"
⅜"
¾"
⅜"
¾" ⁴
Sweat
89
⅜"
¾" ⁴
Sweat
75
⅜"
⅞" ⁵
Sweat
90
⅜"
⅞" ⁵
Sweat
104
⅜"
⅞" ⁵
Sweat
111
⅜"
¾"
Sweat
73
Sweat
76
Sweat
78
Sweat
130
Refrigerant Charge
Shipped with Orifice Size
Electrical Data
0.051
0.057
0.061
0.070
0.070
0.076
0.080
0.086
0.086
Voltage
208/230
9.1
208/230
17.6
208/230
16.7
208/230
18.7
208/230
19.1
208/230
23.9
208/230
26.3
208/230
32.8
208/230
34.5
Minimum Circuit Ampacity ²
Max. Overcurrent Protecꢀon ³
Min / Max Volts
15 amps
197/253
½" or ¾"
106
30 amps
197/253
½" or ¾"
113
25 amps
197/253
½" or ¾"
142
30 amps
197/253
½" or ¾"
139
30 amps
197/253
½" or ¾"
139
40 amps
197/253
½" or ¾"
188
45 amps
197/253
½" or ¾"
191
50 amps
197/253
½" or ¾"
207
60 amps
197/253
½" or ¾"
284
Electrical Conduit Size
Equipment Weight (lbs)
Ship Weight (lbs)
120
130
159
157
157
206
209
225
301
¹
Line sizes denoted for 25’ line sets, tested and rated in accordance with AHRI Standard 210/240. For other line-set lengths or sizes, refer
to the installaꢀon & Operaꢀng instrucꢀons and/or the long line-set guidelines.
²
³
⁴
⁵
Wire size should be determined in accordance with Naꢀonal Electrical Codes; extensive wire runs will require larger wire sizes
Must use ꢀme-delay fuses or HACR-type circuit breakers of the same size as noted.
Installer will need to supply ¾” to ⅞” adapters for sucꢀon line connecꢀons.
Installer will need to supply ⅞” to 1⅛” adapters for sucꢀon line connecꢀons.
Notes
•
•
Always check the S&R plate for electrical data on the unit being installed.
Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installaꢀon Instrucꢀons Final Charge Procedure.
SS-GSX13
3
Product SPecificationS
expAnded Cooling dAtA — gSx130181e* / CApf1824B6dB
4
SS-GSX13
Product SPecificationS
expAnded Cooling dAtA — gSx130181e* / CApf1824B6dB (Cont.)
SS-GSX13
5
Product SPecificationS
expAnded Cooling dAtA — gSx130241d* / CA*f1824*6d*
6
SS-GSX13
Product SPecificationS
expAnded Cooling dAtA — gSx130241d* / CA*f1824*6d* (Cont.)
SS-GSX13
7
Product SPecificationS
expAnded Cooling dAtA — gSx130301B* / CA*f3030*6d*
8
SS-GSX13
Product SPecificationS
expAnded Cooling dAtA — gSx130301B* / CA*f3030*6d* (Cont.)
SS-GSX13
9
Product SPecificationS
expAnded Cooling dAtA — gSx130361C* / CA*f3642*6C*
10
SS-GSX13
Product SPecificationS
expAnded Cooling dAtA — gSx130361C* / CA*f3642*6C* (Cont.)
SS-GSX13
11
Product SPecificationS
expAnded Cooling dAtA — gSx130361e* / CA*f3636*6d*
12
SS-GSX13
Product SPecificationS
expAnded Cooling dAtA — gSx130361e* / CA*f3636*6d* (Cont.)
SS-GSX13
13
Product SPecificationS
expAnded Cooling dAtA — gSx130421B* / CA*f3642*6B*
14
SS-GSX13
Product SPecificationS
expAnded Cooling dAtA — gSx130421B* / CA*f3642*6B* (Cont.)
SS-GSX13
15
Product SPecificationS
expAnded Cooling dAtA — gSx130481B* / CA*f4860*6B*
16
SS-GSX13
Product SPecificationS
expAnded Cooling dAtA — gSx130481B* / CA*f4860*6B* (Cont.)
SS-GSX13
17
Product SPecificationS
expAnded Cooling dAtA — gSx130601B* / CA*f4961*6A*
18
SS-GSX13
|