Fedders C30ABD1VF User Manual

Residential & Light Commercial HVAC  
Split System Air Conditioner  
11⁄  
208/230 Volt, 1-Phase, 60 Hz  
2
thru 5 Tons  
Performance:  
Efficiency rating of 13 SEER and 14 SEER  
Cooling capacities from 11⁄  
to 5 tons  
2
Refrigerant Circuit:  
Factory installed liquid line filter drier  
Long life copper tubes, aluminum fins  
State-of-the-art compressors  
Large, wrap-around coil surface  
Quality Built:  
Galvanized steel exterior cabinet with  
1,000-hour salt spray, powder-coated finish  
Powder-coated fan guard  
Full louvered panel to protect coil  
Formed base with 212" ground clearance  
Limited 5-year warranty on parts  
Easy To Install:  
Factory-charged with R-22 refrigerant  
Only three screws to access electrical controls  
Easy access to service valves  
Rated in Accordance with ARI Standard 210.  
Certification Applies Only When Used with  
Proper Components as Listed with ARI.  
Additional rating information can be found  
Model  
Number  
Size  
(tons)  
Nominal  
BTUH  
Min. Circuit  
Ampacity  
Max. Fuse or  
Breaker  
Operating Dimensions  
H x W x D (inches)  
Min. Mounting Ship / Operating  
Pad Size (inches)  
Weight (lbs)  
144 / 138  
142 / 136  
169 / 163  
189 / 180  
213 / 204  
217 / 208  
230 / 220  
1
1
1
1
C18ABD1VF  
C24ABD1VF  
C30ABD1VF  
C36ACD1VF  
C42ACD1VF  
C48ACD1VF  
C60ACD1VF  
1 ⁄2  
18,000  
24,000  
30,000  
36,000  
42,000  
48,000  
60,000  
9.1  
15  
15  
20  
30  
35  
40  
50  
26 ⁄2 X 21 2 X 21 2  
24 x 24  
1
1
1
2
11.5  
14.3  
18.7  
20.3  
23.1  
30.1  
26 ⁄2 X 21 2 X 21 2  
24 x 24  
1
1
1
1
2 ⁄2  
32 ⁄2 X 21 2 X 21 2  
24 x 24  
1
1
1
3
32 ⁄2 X 29 2 X 29 2  
32 x 32  
1
1
1
1
3 ⁄2  
32 ⁄2 X 29 2 X 29 2  
32 x 32  
1
1
1
4
5
32 ⁄2 X 29 2 X 29 2  
32 x 32  
1
1
39 X 29 2 X 29 2  
32 x 32  
Product Specifications  
ARI CERTIFIED COMBINATION PERFORMANCE RATINGS  
Cooling Capacity (BTUH)  
Factory  
Supplied  
Enhancement  
UNIT  
SIZE  
Outdoor Unit  
Indoor Unit  
SEER1  
EER  
Total  
Sensible  
AC1A024A  
AFPB24A1  
TXV  
17,500  
17,500  
18,000  
21,600  
21,600  
21,600  
21,600  
26,600  
26,600  
26,600  
28,000  
28,000  
34,000  
34,000  
35,000  
35,000  
40,000  
40,000  
41,500  
44,000  
44,000  
53,000  
53,000  
12,750  
12,750  
13,500  
15,750  
15,750  
17,000  
17,000  
19,500  
19,500  
19,500  
21,000  
21,000  
24,750  
24,750  
25,500  
25,500  
29,250  
29,250  
31,000  
32,250  
32,250  
38,750  
38,750  
13  
13  
14  
13  
13  
14  
14  
13  
13  
13  
14  
14  
13  
13  
14  
14  
13  
13  
14  
13  
13  
13  
13  
11.3  
11.3  
12.0  
11.3  
11.3  
12.2  
12.2  
11.4  
11.4  
11.4  
12.0  
12.0  
11.4  
11.4  
11.8  
11.8  
11.5  
11.5  
12.0  
11.5  
11.5  
11.5  
11.5  
18  
24  
C18ABD1VF  
TXV/TDR  
TXV/TDR  
TXV  
AC1A036 + FV80A070-4  
AC1A024A  
AFPB24A1  
TXV/TDR  
TXV/TDR  
TXV/TDR  
TXV  
C24ABD1VF  
C30ABD1VF  
AC1A042A + FV80A070-4  
AC1A042A + FV80A085-4  
AC1A030A  
AC1A036A  
TXV  
30  
AFPB36A1  
TXV/TDR  
TXV/TDR  
TXV/TDR  
TXV  
AC1A060A + FV80A085-4  
AC1A060A + FV80A115-5  
AC1A036A  
AFPB36A1  
TXV/TDR  
TXV/TDR  
TXV/TDR  
TXV  
36  
42  
C36ACD1VF  
C42ACD1VF  
AC1A060A + FV80A085-4  
AC1A060A + FV80A115-4  
AC1A042A  
AFPC48A1  
TXV/TDR  
TXV/TDR  
TXV  
AC1A060A + FV80A115-5  
AC1A060A  
48  
60  
C48ACD1VF  
C60ACD1VF  
AFPC48A1  
TXV/TDR  
TXV  
AC1A060A  
AFPC60A1  
TXV/TDR  
1. TDR required to obtain SEER rating  
Notes:  
a. Fedders coils include factory installed TXV. Fedders gas furnaces and air handlers  
contain the TDR as standard equipment.  
b. TDR kit available as accessory. Part Number TDR001A.  
c. Tested outdoor and indoor combinations have been tested in accordance with  
DOE test procedures for central air conditioners.  
d. Above ratings based on 80ºF (27ºC) DB and 67ºF (19ºC) WB indoor entering  
air temperature and 95ºF (35ºC) DB air entering outdoor unit.  
EER  
-
-
-
-
Energy Efficiency Ratio  
Seasonal Energy Efficiency Ratio  
Time-Delay Relay  
SEER  
TDR  
TXV  
Thermostatic Expansion Valve  
3
Specifications subject to change without notice.  
Product Specifications  
LINE SET LENGTH AND SIZE  
SUCTION LINE SIZES  
LIQUID LINE SIZES  
25 ft. 50 ft.  
3/8" 3/8"  
BTUH  
15 ft.  
3/4"  
3/4"  
7/8"  
7/8"  
7/8"  
7/8"  
1 1/8"  
25 ft.  
3/4"  
3/4"  
7/8"  
7/8"  
7/8"  
7/8"  
1 1/8"  
50 ft.  
3/4"  
3/4"  
7/8"  
7/8"  
7/8"  
7/8"  
1 1/8"  
75 ft.  
3/4"  
15 ft.  
3/8"  
3/8"  
3/8"  
3/8"  
3/8"  
3/8"  
1/2"  
75 ft.  
3/8"  
3/8"  
3/8"  
3/8"  
3/8"  
3/8"  
1/2"  
18  
24  
30  
36  
42  
48  
60  
3/4"  
3/8"  
3/8"  
3/8"  
3/8"  
3/8"  
1/2"  
3/8"  
3/8"  
3/8"  
3/8"  
3/8"  
1/2"  
7/8"  
7/8"  
1 1/8"  
1 1/8"  
1 1/8"  
Recommended liquid and suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and  
15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied  
by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet  
vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.)  
Note: See unit installation instructions for proper installation.  
EXTENDED COOLING CAPACITIES  
RATINGS AT  
CONDENSER ENTERING AIR TEMPERATURE DEGREES (F)  
OUTDOOR  
UNIT MODEL  
STANDARD CONDITIONS  
INDOOR UNIT  
BTUH SEER*  
CFM  
80  
85  
90  
95  
100  
105  
110  
115  
TOTAL  
SENSIBLE 13,900 13,550 13,150 12,750 12,250 11,800 11,300 10,850  
TOTAL 19,700 19,100 18,600 18,000 17,400 16,900 16,300 15,800  
SENSIBLE 14,300 14,000 13,800 13,500 13,200 12,900 12,500 12,100  
TOTAL 23,700 22,900 22,150 21,600 20,700 19,950 19,150 18,400  
SENSIBLE 17,300 16,750 16,200 15,750 15,100 14,550 14,000 13,500  
TOTAL 24,000 23,200 22,400 21,600 20,600 19,800 19,000 18,200  
SENSIBLE 17,900 17,600 17,300 17,000 16,600 16,300 16,000 15,700  
TOTAL 29,150 28,300 27,500 26,600 25,650 24,750 23,850 23,000  
SENSIBLE 21,300 20,750 20,100 19,500 18,750 18,100 17,500 16,800  
TOTAL 31,000 30,000 29,000 28,000 27,000 26,000 25,000 24,200  
SENSIBLE 22,200 21,800 21,400 21,000 20,600 20,200 19,800 19,400  
TOTAL 37,000 36,200 35,150 34,000 32.900 31,800 30,700 29,650  
SENSIBLE 27,000 26,450 25,650 24,750 24,000 23,250 22,500 21,650  
TOTAL 39,000 37,600 36,400 35,000 34,000 33,000 31,800 30,600  
SENSIBLE 27,200 26,600 26,200 25,500 25,000 24,600 24,200 23,600  
TOTAL 43,450 42,300 41,150 40,000 38,800 37,650 36,550 35,500  
SENSIBLE 31,750 30,850 30,100 29,250 28,350 27,500 26,700 25,950  
TOTAL 47,650 46,400 45,250 44,000 42,700 41,550 40,330 39,200  
SENSIBLE 34,750 33,850 33,100 32,250 31,200 30,500 29,400 28,650  
TOTAL 56,600 55,400 54,150 53,000 51,800 50,600 49,500 48,600  
19,100 18,550 18,025 17,500 16,800 16,150 15,550 14,850  
AC1A024A  
17,500  
18,000  
21,600  
21,600  
26,600  
28,000  
34,000  
35,000  
40,000  
44,000  
53,000  
13  
14  
13  
14  
13  
14  
13  
14  
13  
13  
13  
650  
C18ABD1VF  
C24ABD1VF  
C30ABD1VF  
C36ACD1VF  
AC1A036A + FV80A070-4  
AC1A024A  
640  
810  
AC1A042A + FV80A070-4 /  
AC1A042A + FV80A085-4  
810  
AC1A030A  
1,000  
1,000  
1,150  
1,150  
1,350  
1,550  
1,750  
AC1A060A + FV80A085-4 /  
AC1A060A + FV80A115-5  
AC1A036A  
AC1A060A + FV80A085-4 /  
AC1A060A + FV80A115-5  
C42ACD1VF  
C48ACD1VF  
C60ACD1VF  
AC1A042A  
AC1A048A  
AC1A060A  
SENSIBLE 41,250 40,500 39,550 38,750 37,850 36,950 36,150 35,500  
*TDR required to obtain SEER rating.  
4
Specifications subject to change without notice.  
Product Specifications  
5
Specifications subject to change without notice.  
Product Specifications  
Residential & Light Commercial  
AC Condensing Units  
Model Number Identification  
C 24 A B D 1 V F * A  
Product Type  
C = Air Conditioner  
CH = Heat Pump  
Brand  
Fitting Type  
V = Sweat  
Nominal Capacity  
18 = 18,000 BTUH [5.28 kW]  
24 = 24,000 BTUH [7.03 kW]  
30 = 30,000 BTUH [8.79 kW]  
36 = 36,000 BTUH [10.55 kW]  
42 = 42,000 BTUH [12.31 kW]  
48 = 48,000 BTUH [14.07 kW]  
60 = 60,000 BTUH [17.58 kW]  
Electrical Designation  
1 = 208 / 230 Volts, 1 Phase, 60 Hz  
2 = 220 Volts, 1 Phase, 50 Hz  
3 = 208 / 230 Volts, 3 Phase, 60 Hz  
4 = 460 Volts, 3 Phase, 60 Hz  
5 = 230 Volts, 3 Phase, 50 Hz  
6 = 380 Volts, 3 Phase, 50 Hz  
Series  
Chassis Size  
Refrigerant Variations  
D = R-22 Refrigerant  
B = 2112" W x 2112" D x H - Determined by BTU Size  
C = 2912" W x 2912" D x H - Determined by BTU Size  
Fedders Corporation  
505 Martinsville Rd.  
Liberty Corner, NJ 07938  
(908) 604-8686  
All product specifications reflect available information at the printing of this brochure.  
Fedders reserves the right to revise or modify products and/or specifications without notice.  
©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.  
FD-071 0507  
Form No. F-C13  

Briggs Stratton Automobile Parts 540000 User Manual
Canon MultiPASS MP730 User Manual
Carrier 17EX User Manual
Continental KL83129 User Manual
Cornelius IntelliCarb Cold Beverage Dispenser User Manual
Datalogic Scanning Barcode Reader 1100I OEM User Manual
Friedrich Air Conditioner WY12 User Manual
Friedrich EQ08 User Manual
Gamber Johnson Automobile Accessories MCS EPIC9 User Manual
Honda Automobiles Automobile Accessories CT90 User Manual