| RB787WC/BC - Hotpoint 30" Free-Standing Self-Cleaning Electric Range   Dimensions (in inches)   KW Rating   7-1/2   29-7/8   240V   208V   10.5   7.9   7 7-1/2   5 3-1/2   Breaker Size   2-1/4   REAR   WALL   † 40 Amps   2-1/4   † Note: Check local codes for required breaker size.   CENTER LINE   46-1/2   A properly grounded branch circuit with a 3 prong grounding type   receptacle is required for Hotpoint ranges.   1/4†   Note: 30" Electric Ranges conform to U.L. requirements for 0" spacing   from walls below countertops. However some kitchen cabinet   finishes can be damaged by heat from the range heating elements. It   is recommended that a clearance of at least 1-1/2 inches be maintained   to walls. Where varnished wood or plastic film finishes are used, a   minimum clearance of 6 inches should be maintained.   † The range may be placed with   0" clearance (flush) at the back   wall and side walls if the range   side trims extend beyond the   cabinet fronts at least 1/4".   Self-Clean models only   26-3/8*   Receptacle Locations: Locally approved flexible service cord or conduit   must be used because terminals are not accessible after range   installation. See shaded area in drawing for location of electrical outlet   box. Recommended outlet locations allow range to be installed directly   against rear wall.   46-3/8   *Dimension from wall to front of closed oven door.   Dimension from wall to the front of closed oven   door handle is 28-1/2.   Installation Information: Before installing, consult installation   instructions packed with product for current dimensional data.   All Hotpoint ranges are equipped   with an Anti-Tip device. The   installation of this device is   an important, required step in   the installation of the range.   Listed by   Underwriters   Laboratories   R Specification Created 7/00   Download from Www.Somanuals.com. All Manuals Search And Download.   |