Hoshizaki Ice Maker IM 51BAE User Manual

1
IM SERVICE TRAINING  
Featuring the  
IM-51BAE  
80041  
9/9/99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
This horizontal evaporator and water  
distribution system is unique to the  
IM series.  
The ABS water plate sprays water up  
into the evaporator cells to form the  
square IM cube.  
The moveable water pan assembly  
includes the water plate, reservoir  
pan, and pump motor assembly.  
Tension springs connect two cam  
arms to the water plate assembly. An  
actuator motor rotates the cam arms  
to raise and lower the water pan  
during the ice making cycle.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
The front cam arm has a switch lever  
that operates the actuator toggle  
switch located above the pan  
assembly.  
The actuator toggle switch controls  
the direction of rotation for the  
actuator motor and energizes the  
pump motor during the freeze cycle.  
· When the switch is in the right  
position, the actuator motor  
rotates counter clock wise to  
lower the water pan assembly.  
· When the switch is in the left  
position, the actuator motor turns  
clock wise to raise the water pan  
assembly.  
The IM51 uses a mechanical  
proximity switch bin control  
assembly located in the bin area.  
When ice fills the bin and pushes the  
control arm over, the activator  
magnet moves to the switch and  
closes the contacts.  
The IM bin control closes the  
contacts to signal the control board  
to shut down the unit. This is  
different from the standard KM  
control, which opens the contacts to  
de-energize the unit.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
The louver has a flip down cover to  
access the control switch.  
The switch has 3 positions.  
ICE, OFF, & WASH.  
The louver covers the compressor  
compartment. Remove the louver  
screws and lift the louver forward to  
access the condenser coil fan  
assembly and compressor.  
For easy access during preventative  
maintenance or service, the inlet  
water valve is located in the front  
right hand corner of the compressor  
compartment.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
The control box is accessed from the  
rear of the unit. Remove the screws  
holding the pipe cover and the  
control box cover to reach the  
control board and other components.  
A solid state board controls the IM  
operation. Several adjustments are  
included on the board. These  
adjustments are factory set for proper  
operation.  
Later, we will cover the adjustments  
and discuss the proper settings.  
Now, lets take a look at the basic IM  
sequence of operation. When the  
control switch is placed in ICE, the  
unit starts in the Initial Harvest cycle.  
CONTROL SWITCH TO ICE.  
INITIAL HARVEST CYCLE.  
When power is supplied, the  
compressor, hot gas valve, and  
actuator motor energize. The  
FREEZE CYCLE.  
compressor starts in harvest to  
reduce the starting load and increase  
compressor life. This will also clear  
any ice from the evaporator plate  
before the freeze cycle begins.  
NORMAL HARVEST CYCLE.  
FREEZE, HARVEST,  
FREEZE, HARVEST,  
FREEZE, HARVEST,  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
The actuator motor turns counter  
clock wise to rotate the cam arms  
and lower the water pan away from  
the evaporator. When the water plate  
is completely down the switch lever  
moves the actuator toggle switch to  
the left. The board energizes the  
inlet water valve and condenser fan  
motor and de-energizes the hot gas  
valve.  
Switching the actuator toggle switch  
to the left position also reverses the  
actuator motor. The motor now turns  
clock wise to raise the water plate  
upward.  
When the plate reaches the  
evaporator, the cam arm switch lever  
moves the actuator toggle switch to  
the right position. This stops the  
actuator motor and sets up the circuit  
to lower the plate in the next harvest  
cycle. It also energizes the pump  
motor and the board de-energizes the  
inlet water valve. The Freeze Cycle  
now begins.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
The freeze cycle is controlled by a  
thermistor, which is mounted at the  
evaporator outlet. The pump is  
spraying water up into the evaporator  
cells to form the square IM cubes.  
The evaporator temperature lowers  
as the ice cubes form.  
A thermistor temperature of 9.4°F  
signals the control board to begin  
harvest and energize the hot gas  
valve and actuator motor circuit. The  
actuator motor now turns counter  
clock wise to lower the water pan.  
The switch lever moves the actuator  
toggle switch to the left. This sets the  
actuator motor circuit to raise the  
water plate at the end of harvest. The  
board energizes the inlet water valve.  
Unlike the initial harvest, the normal  
harvest is controlled by the  
thermistor. When the thermistor  
reaches 59°F, the control board de-  
energizes the hot gas valve and  
energizes the condenser fan motor.  
The actuator motor energizes to raise  
the plate. When the plate reaches the  
evaporator, the actuator toggle  
switch is moved back to the right.  
The board de-energizes the inlet  
water valve and the freeze cycle  
begins again. The average harvest  
cycle is about 3 minutes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
The unit will continue through the  
freeze and harvest cycle until the bin  
control shuts down the refrigeration  
system.  
When pushed over, the bin control  
has a 10-second delay before shut  
down occurs. An 85-second delay  
occurs at startup when the bin  
control is released.  
Now let’s take a look at the control  
board adjustments. Remember that  
the adjustments are factory set to  
provide proper operation in normal  
operating conditions.  
NO SEASONAL  
ADJUSTMENTS!  
The board adjustments are made  
through variable resistors on the  
board. The cube control is marked  
VR5. This adjusts the thermistor  
switching temperature of - 9.4°F and  
the length of the freeze cycle. The  
dimple size in the cube also changes.  
Adjusting to a larger dimple will  
result in a shorter freeze cycle and a  
smaller cube. A smaller dimple  
setting will result in a longer cycle  
and a larger cube. The factory  
setting is 5.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
The maximum freeze timer is VR3.  
This timer will automatically switch  
the unit to the harvest cycle if the  
freeze cycle last longer than the  
setting time. The factory setting is  
45 minutes.  
The defrost control VR2 will adjust  
the time period between ice-drop and  
actuator motor restart during harvest.  
The factory setting is 4. This setting  
represents approximately 40 seconds.  
VR2 would be adjusted longer if the  
unit is operating in a cooler ambient  
temperature.  
The control board includes a push-  
button reset. Pressing this button  
will initiate a harvest cycle anytime  
the control switch is in ICE position.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
A red Service Indicator LED is also  
included on the control board. This  
LED will either light continually or  
flash to indicate a service fault. A  
fault diagnosis chart in the service  
manual will help the technician  
determine the actual problem.  
See chart next page.  
Preventative maintenance for the IM  
is simple. Follow these steps to allow  
the unit to operate efficiently.  
1. Clean the mesh air filter twice  
monthly to ensure good airflow.  
2. Clean the condenser once a year  
using a brush or vacuum.  
3. Check and clean the inlet water  
valve screen as needed to assure  
proper water flow.  
4. Clean and sanitize the water  
distribution system annually using  
the recommended cleaner.  
5. Wipe down the exterior using a  
soft cloth and neutral cleaner.  
Cleaning tips:  
· A detailed cleaning label is  
located under the top cover. More  
detailed instructions are included  
in the customers Instruction  
Manual or in the product Service  
Manual.  
· Always follow the cleaning  
instructions and use the  
recommended ice machine  
cleaner.  
· Use the cleaning brush shipped  
with the unit to clean tight places.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
FAULT DIAGNOSIS  
Check the status of the Service lamp on the Controller Board (LED-5) by removing the  
Control Box Cover.  
Lamp ON Water Plate closed  
This tends to indicate the Back-up Timer has stopped machine operation during the  
freeze cycle. High ambient and water temperature are an obvious cause. But check  
out each component that could result in an extended freezing time (See guide below).  
Lamp ON – Water Plate open  
The Timer has stopped the machine because if an excessive defrost time. See the  
guide below to check out the probable cause.  
Lamp flashing ON/OFF  
If on the first cycle, check out the Cam operation and/or Toggle Switch. If the machine  
has been in service for some time, the Controller Board may be at fault.  
REMEMBER: Hoshizaki controllers are very reliable. They also control every component’s  
Operation. So if a component malfunctions, the controller will respond.  
Do not replace controllers in an attempt to shorten the diagnosis process and  
not before carefully checking the actual fault and possible cause.  
When the icemaker stops, the Controller Board Interlock indicator shows possible faults.  
INTERLOCK  
INDICATOR  
WATER TANK  
POSITION  
PATTERN  
POSSIBLE CAUSE  
REMEDY  
1.  
Actuator  
Toggle Switch  
Lever bent  
Replace  
Actuator  
Toggle  
Switch  
1
2
Only  
First  
Cycle  
Flashing  
Can Arm (A) Broken  
Cam Arm  
Replace  
3
4
Replace  
Replace  
Defective  
Actuator Motor  
O
Defective  
Controller Board  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
INTERLOCK  
INDICATOR  
WATER TANK  
POSITION  
PATTERN  
POSSIBLE CAUSE  
Clogged Air Filter  
REMEDY  
2
Clean or  
Replace  
1
and/or Condenser  
Water leak from  
Water Solenoid  
Valve  
2
0V  
Replace  
Replace  
Leak  
Freeze Cycle  
Gas leak from Hot  
Gas Solenoid  
Valve  
3
4
Hot Gas leak  
Fan Motor  
stopped  
Replace  
Check  
for leak  
Gas leak  
5
6
Gas  
Replace  
Comp. Start  
Capacitor  
Compressor  
stopped  
3
Hot Gas Solenoid  
Valve closed and  
will not open  
1
Replace  
115v  
Check  
for leak  
Gas leak  
2
3
Gas  
Harvest  
Cycle  
Replace  
Comp. Start  
Capacitor  
Compressor  
stopped  
4
Replace  
Actuator  
Toggle Swt.  
Actuator  
Toggle Switch  
Lever bent  
1
Lever  
2
3
Can Arm (A) Broken  
Cam Arm  
Replace  
Replace  
OR  
Defective Actuator  
Motor  
Cam Pin  
damaged  
Replace  
Cam Pin  
and Cam  
Arm (A)  
4
Actuator  
motor  
Pin  
Defective Cube  
Control Thermistor  
Replace  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
WIRING DIAGRAM  
IM-51BAE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
IM SERIES REVIEW QUIZ  
Choose the best answer for each question below.  
1. The IM control board is located in the rear or the unit.  
True  
False  
2. The IM unit uses a thermostatic bin control.  
True  
False  
3. The bin control switch must OPEN or Close to shut the unit down.  
4. The IM series uses R-404A or R-134A refrigerant.  
5. To raise the water pan assembly the actuator toggle switch must be in the  
RIGHT or LEFT position.  
6. With the actuator toggle switch in the left position, the actuator motor turns  
CLOCKWISE or COUNTER CLOCKWISE.  
7. Adjusting the cube control or dimple adjustment changes which temperature  
setting? - 9.4ºF or 59ºF.  
8. The maximum freeze timer on the control board is factory set at  
60 MINUTES or 45 MINUTES.  
9. The black push button reset is included on the control board for  
HARVEST INITIATION or SAFETY RESET.  
10. The control transformer used in the IM series units is a 12VOLT or 24  
VOLT output.  
NOTE: Quiz answers are at the bottom of next page.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
NOTES:  
Quiz answers:  
1.True, 2. False, 3. Close, 4. R-134A , 5. Left , 6. CW , 7. – 9.4ºF, 8. 45 min., 9. Harvest initiation, 10. 24 volt  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Swing Sets 1602 User Manual
Greenheck Fan Ventilation Hood FSD 311V User Manual
Grizzly Hunting Equipment H5844 User Manual
Grizzly Saw H7197 User Manual
Haier Microwave Oven EB 3190EG User Manual
Hamilton Beach Iron 14X60 User Manual
Honeywell Food Saver PUL1012S User Manual
Hotpoint Clothes Dryer TCEM 80C User Manual
Hotpoint Range RGB528BEAAD User Manual
Hubbell Lawn Mower SZ 18 User Manual