Owner’s Manual
Installation and Operation
Model(s):
NNXT4236I, NNXT4236IL
NNXT3933I, NNXT3933IL
CAUTION
DO NOT DISCARD THIS MANUAL
•
Read, understand and follow
these instructions for safe
installation and operation.
•
Leave this manual with
party responsible for
use and operation.
• Important operating and
maintenance instructions
included.
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
flammable materials.
• What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• Keep clothing, furniture, draperies and other combustibles
away.
This appliance has been supplied with an integral
barrier to prevent direct contact with the fixed glass
panel. Do NOT operate the appliance with the barrier
removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
In the Commonwealth of Massachusetts installation must
be performed by a licensed plumber or gas fitter;
This appliance may be installed as an OEM installation
in manufactured home (USA only) or mobile home and
must be installed in accordance with the manufacturer’s
instructions and the manufactured home construction and
safety standard, Title 24 CFR, Part 3280 or Standard for
Installation in Mobile Homes, CAN/CSA Z240MH.
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be performed
by qualified personnel. Hearth & Home Technologies
suggests NFI certified or factory-trained professionals, or
technicians supervised by an NFI certified professional.
This appliance is only for use with the type(s) of gas
indicated on the rating plate.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
A. Congratulations
B. Limited Lifetime Warranty
2
5
6 Termination Locations
A. Vent Termination Minimum Clearances
22
1 Listing and Code Approvals
A. Appliance Certification
7 Vent Information and Diagrams
A. Approved Pipe
7
7
7
7
7
7
7
24
24
24
24
25
B. Glass Specifications
C. BTU Specifications
B. Vent Table Key
C. Use of Elbows
D. Measuring Standards
E. Vent Diagrams
D. High Altitude Installations
E. Non-Combustible Materials Specification
F. Combustible Materials Specification
G. Electrical Codes
H. Requirements for the Commonwealth
of Massachusetts
8 Vent Clearances and Framing
A. Pipe Clearances to Combustibles
B. Wall Penetration Framing
35
35
36
37
8
C. Install the Ceiling Firestop
D. Install Attic Insulation Shield
User Guide
9 Appliance Preparation
A. Top Vent
38
39
40
2 Operating Instructions
A. Gas Fireplace Safety
B. Your Fireplace
B. Rear Vent
C. Secure and Level the Appliance
9
9
10
10
10
10
10 Install Vent Pipe
C. Fan Kit (optional)
A. Assemble Vent Sections (DVP Only)
B. Assemble Vent Sections (SLP Only)
C. Assemble Slip Sections
D. Secure the Vent Sections
E. Disassemble Vent Sections
F. Install Decorative Ceiling Components
(SLP only)
G. Install Metal Roof Flashing
H. Assemble and Install Storm Collar
I. Install Vertical Termination Cap
J. Install Decorative Wall Components (SLP only) 46
K. Heat Shield Requirements for Horizontal
41
42
42
43
43
D. Clear Space
E. Decorative Doors and Fronts
F. Fixed Glass Assembly
G. Remote Controls, Wall Controls and Wall
Switches
H. IPI Battery Tray/Battery Installation
I. Control Module Operation
J. Before Lighting Fireplace
K. Lighting Instructions (IPI)
L. After Fireplace is Lit
10
11
11
11
12
13
13
44
45
45
46
M. Frequently Asked Questions
3 Maintenance and Service
Termination
L. Install Horizontal Termination Cap
46
47
A. Maintenance Tasks-Homeowner
14
B. Maintenance Tasks-Qualified Service Technician 15
11 Shrouds
A. HHT Shrouds
B. Field Constructed Shrouds
48
48
Installer Guide
12 Gas Information
4 Getting Started
A. Fuel Conversion
B. Gas Pressure
C. Gas Connection
D. High Altitude Installations
50
50
50
50
A. Typical Appliance System
B. Design and Installation Considerations
C. Tools and Supplies Needed
16
17
17
17
D. Inspect Appliance and Components
13 Electrical Information
5 Framing and Clearances
A. Select Appliance Location
B. Construct the Appliance Chase
C. Clearances
A. Wiring Requirements
51
51
51
52
53
53
54
18
19
20
21
B. Intellifire Plus™ Ignition System Wiring
C. Optional Accessories Requirements
D. Electrical Service and Repair
E. Junction Box Installation
F. Wall Switch Installation for Fan (Optional)
G. Remote Control Installation & Operations
D. Mantel and Wall Projections
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
3
14 Finishing
A. Mantel and Wall Projections
B. Facing Material
58
59
15 Appliance Setup
A. Remove the Packaging
B. Remove Screen Package Assembly
C. Remove the Shipping Materials
D. Removing Fixed Glass Assembly
E. Remove Top Log Pack
F. Remove Packing Material
G. Clean the Appliance
H. Accessories
I. Place the Rockwool
J. Place the Lava Rock
K. Place the Vermiculite
L. Assemble Logs
M. Replacing Fixed Glass Assembly
N. Air Shutter Setting
O. Remove Screen Protector
P. Unpackage the Hood & Floor Cover
Q. Install Hood
R. Install Control Heat Shield
S. Install Floor Cover
60
60
60
60
60
60
61
61
61
61
61
61
62
62
63
63
63
63
64
65
T. Close the Screen Assembly
16 Troubleshooting
A. Intellifire Plus™ Intermittent Ignition System
66
17 Reference Materials
A. Appliance Dimension Diagram
B. Vent Components Diagrams
C. Service Parts
68
69
77
81
82
D. Optional Components
E. Contact Information
= Contains updated information.
4
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Limited Lifetime Warranty
Hearth & Home Technologies Inc.
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for
HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY COVERAGE:
HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership
of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance
will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo-
nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period,
HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its
obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product
itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty
is subject to conditions, exclusions and limitations as described below.
WARRANTY PERIOD:
Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage
begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent,
authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months
following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for
parts and labor for covered components is produced in the following table.
The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for
gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These
time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.
Warranty Period
Parts Labor
HHT Manufactured Appliances and Venting
EPA
Components Covered
Gas
X
Wood Pellet
Coal Electric Venting
Wood
All parts and material except as
covered by Conditions,
Exclusions, and Limitations
listed
1 Year
X
X
X
X
X
X
Igniters, electronic components,
and glass
X
X
X
X
X
X
2 years
X
X
X
Factory-installed blowers
Molded refractory panels
3 years
X
X
Firepots and burnpots
Castings and baffles
5 years 1 year
X
X
Manifold tubes,
HHT chimney and termination
7 years 3 years
X
X
10
1 year
years
X
X
X
Burners, logs and refractory
Firebox and heat exchanger
Limited
3 years
Lifetime
X
X
X
X
X
X
X
X
All replacement parts
beyond warranty period
90 Days
X
X
See conditions, exclusions, and limitations on next page.
4021-645C 12-29-10
Page 1 of 2
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
5
B. Limited Lifetime Warranty (continued)
WARRANTY CONDITIONS:
ꢀ 7KLVꢀZDUUDQW\ꢀRQO\ꢀFRYHUVꢀ++7ꢀDSSOLDQFHVꢀWKDWꢀDUHꢀSXUFKDVHGꢀWKURXJKꢀDQꢀ++7ꢀDXWKRUL]HGꢀGHDOHUꢀRUꢀGLVWULEXWRUꢁꢀ$ꢀOLVWꢀRIꢀ
++7ꢀDXWKRUL]HGꢀGHDOHUVꢀLVꢀDYDLODEOHꢀRQꢀWKHꢀ++7ꢀEUDQGHGꢀZHEVLWHVꢁ
ꢀ 7KLVꢀZDUUDQW\ꢀLVꢀRQO\ꢀYDOLGꢀZKLOHꢀWKHꢀ++7ꢀDSSOLDQFHꢀUHPDLQVꢀDWꢀWKHꢀVLWHꢀRIꢀRULJLQDOꢀLQVWDOODWLRQꢁ
ꢀ &RQWDFWꢀ\RXUꢀLQVWDOOLQJꢀGHDOHUꢀIRUꢀZDUUDQW\ꢀVHUYLFHꢁꢀ,IꢀWKHꢀLQVWDOOLQJꢀGHDOHUꢀLVꢀXQDEOHꢀWRꢀSURYLGHꢀQHFHVVDU\ꢀSDUWVꢂꢀFRQWDFWꢀ
WKHꢀQHDUHVWꢀ++7ꢀDXWKRUL]HGꢀGHDOHUꢀRUꢀVXSSOLHUꢁꢀ$GGLWLRQDOꢀVHUYLFHꢀIHHVꢀPD\ꢀDSSO\ꢀLIꢀ\RXꢀDUHꢀVHHNLQJꢀZDUUDQW\ꢀVHUYLFHꢀ
IURPꢀDꢀGHDOHUꢀRWKHUꢀWKDQꢀWKHꢀGHDOHUꢀIURPꢀZKRPꢀ\RXꢀRULJLQDOO\ꢀSXUFKDVHGꢀWKHꢀSURGXFWꢁ
ꢀ &KHFNꢀZLWKꢀ\RXUꢀGHDOHUꢀLQꢀDGYDQFHꢀIRUꢀDQ\ꢀFRVWVꢀWRꢀ\RXꢀZKHQꢀDUUDQJLQJꢀDꢀZDUUDQW\ꢀFDOOꢁꢀ7UDYHOꢀDQGꢀVKLSSLQJꢀFKDUJHVꢀ
IRUꢀSDUWVꢀDUHꢀQRWꢀFRYHUHGꢀE\ꢀWKLVꢀZDUUDQW\ꢁ
WARRANTY EXCLUSIONS:
7KLVꢀZDUUDQW\ꢀGRHVꢀQRWꢀFRYHUꢀWKHꢀIROORZLQJꢅ
ꢀ &KDQJHVꢀLQꢀVXUIDFHꢀILQLVKHVꢀDVꢀDꢀUHVXOWꢀRIꢀQRUPDOꢀXVHꢁꢀ$VꢀDꢀKHDWLQJꢀDSSOLDQFHꢂꢀVRPHꢀFKDQJHVꢀLQꢀFRORUꢀRIꢀLQWHULRUꢀDQGꢀ
H[WHULRUꢀVXUIDFHꢀILQLVKHVꢀPD\ꢀRFFXUꢁꢀ7KLVꢀLVꢀQRWꢀDꢀIODZꢀDQGꢀLVꢀQRWꢀFRYHUHGꢀXQGHUꢀZDUUDQW\ꢁ
ꢀ 'DPDJHꢀWRꢀSULQWHGꢂꢀSODWHGꢂꢀRUꢀHQDPHOHGꢀVXUIDFHVꢀFDXVHGꢀE\ꢀILQJHUSULQWVꢂꢀDFFLGHQWVꢂꢀPLVXVHꢂꢀVFUDWFKHVꢂꢀPHOWHGꢀLWHPVꢂꢀ
RUꢀRWKHUꢀH[WHUQDOꢀVRXUFHVꢀDQGꢀUHVLGXHVꢀOHIWꢀRQꢀWKHꢀSODWHGꢀVXUIDFHVꢀIURPꢀWKHꢀXVHꢀRIꢀDEUDVLYHꢀFOHDQHUVꢀRUꢀSROLVKHVꢁ
ꢀ 5HSDLUꢀRUꢀUHSODFHPHQWꢀRIꢀSDUWVꢀWKDWꢀDUHꢀVXEMHFWꢀWRꢀQRUPDOꢀZHDUꢀDQGꢀWHDUꢀGXULQJꢀWKHꢀZDUUDQW\ꢀSHULRGꢁꢀ7KHVHꢀSDUWVꢀ
LQFOXGHꢅꢀSDLQWꢂꢀZRRGꢂꢀSHOOHWꢀDQGꢀFRDOꢀJDVNHWVꢂꢀILUHEULFNVꢂꢀJUDWHVꢂꢀIODPHꢀꢀJXLGHVꢂꢀOLJKWꢀEXOEVꢂꢀEDWWHULHVꢀDQGꢀWKHꢀGLVFRORU-
DWLRQꢀRIꢀJODVVꢁ
ꢀ 0LQRUꢀH[SDQVLRQꢂꢀFRQWUDFWLRQꢂꢀRUꢀPRYHPHQWꢀRIꢀFHUWDLQꢀSDUWVꢀFDXVLQJꢀQRLVHꢁꢀ7KHVHꢀFRQGLWLRQVꢀDUHꢀQRUPDOꢀDQGꢀFRP-
SODLQWVꢀUHODWHGꢀWRꢀWKLVꢀQRLVHꢀDUHꢀQRWꢀFRYHUHGꢀE\ꢀWKLVꢀZDUUDQW\ꢁ
ꢀ 'DPDJHVꢀUHVXOWLQJꢀIURPꢅꢀꢆꢇꢈꢀIDLOXUHꢀWRꢀLQVWDOOꢂꢀRSHUDWHꢂꢀRUꢀPDLQWDLQꢀWKHꢀDSSOLDQFHꢀLQꢀDFFRUGDQFHꢀZLWKꢀWKHꢀLQVWDOODWLRQꢀ
LQVWUXFWLRQVꢂꢀRSHUDWLQJꢀLQVWUXFWLRQVꢂꢀDQGꢀOLVWLQJꢀDJHQWꢀLGHQWLILFDWLRQꢀODEHOꢀIXUQLVKHGꢀZLWKꢀWKHꢀDSSOLDQFHꢄꢀꢆꢉꢈꢀIDLOXUHꢀWRꢀ
LQVWDOOꢀWKHꢀDSSOLDQFHꢀLQꢀDFFRUGDQFHꢀZLWKꢀORFDOꢀEXLOGLQJꢀFRGHVꢄꢀꢆꢊꢈꢀVKLSSLQJꢀRUꢀLPSURSHUꢀKDQGOLQJꢄꢀꢆꢋꢈꢀLPSURSHUꢀRSHUD-
WLRQꢂꢀDEXVHꢂꢀPLVXVHꢂꢀFRQWLQXHGꢀRSHUDWLRQꢀZLWKꢀGDPDJHGꢂꢀFRUURGHGꢀRUꢀIDLOHGꢀFRPSRQHQWVꢂꢀDFFLGHQWꢂꢀRUꢀLPSURSHUO\ꢌꢀ
LQFRUUHFWO\ꢀSHUIRUPHGꢀUHSDLUVꢄꢀꢆꢍꢈꢀHQYLURQPHQWDOꢀFRQGLWLRQVꢂꢀLQDGHTXDWHꢀYHQWLODWLRQꢂꢀQHJDWLYHꢀSUHVVXUHꢂꢀRUꢀGUDIWLQJꢀ
FDXVHGꢀE\ꢀWLJKWO\ꢀVHDOHGꢀFRQVWUXFWLRQVꢂꢀLQVXIILFLHQWꢀPDNHꢃXSꢀDLUꢀVXSSO\ꢂꢀRUꢀKDQGOLQJꢀGHYLFHVꢀVXFKꢀDVꢀH[KDXVWꢀIDQVꢀRUꢀ
IRUFHGꢀDLUꢀIXUQDFHVꢀRUꢀRWKHUꢀVXFKꢀFDXVHVꢄꢀꢆꢎꢈꢀXVHꢀRIꢀIXHOVꢀRWKHUꢀWKDQꢀWKRVHꢀVSHFLILHGꢀLQꢀWKHꢀRSHUDWLQJꢀLQVWUXFWLRQVꢄꢀꢆꢏꢈꢀ
LQVWDOODWLRQꢀRUꢀXVHꢀRIꢀFRPSRQHQWVꢀQRWꢀVXSSOLHGꢀZLWKꢀWKHꢀDSSOLDQFHꢀRUꢀDQ\ꢀRWKHUꢀFRPSRQHQWVꢀQRWꢀH[SUHVVO\ꢀDXWKRUL]HGꢀ
DQGꢀDSSURYHGꢀE\ꢀ++7ꢄꢀꢆꢐꢈꢀPRGLILFDWLRQꢀRIꢀWKHꢀDSSOLDQFHꢀQRWꢀH[SUHVVO\ꢀDXWKRUL]HGꢀDQGꢀDSSURYHGꢀE\ꢀ++7ꢀLQꢀZULWLQJꢄꢀ
DQGꢌRUꢀꢆꢑꢈꢀLQWHUUXSWLRQVꢀRUꢀIOXFWXDWLRQVꢀRIꢀHOHFWULFDOꢀSRZHUꢀVXSSO\ꢀWRꢀWKHꢀDSSOLDQFHꢁ
ꢀ 1RQꢃ++7ꢀYHQWLQJꢀFRPSRQHQWVꢂꢀKHDUWKꢀFRPSRQHQWVꢀRUꢀRWKHUꢀDFFHVVRULHVꢀXVHGꢀLQꢀFRQMXQFWLRQꢀZLWKꢀWKHꢀDSSOLDQFHꢁ
ꢀ $Q\ꢀSDUWꢀRIꢀDꢀSUHꢃH[LVWLQJꢀILUHSODFHꢀV\VWHPꢀLQꢀZKLFKꢀDQꢀLQVHUWꢀRUꢀDꢀGHFRUDWLYHꢀJDVꢀDSSOLDQFHꢀLVꢀLQVWDOOHGꢁ
ꢀ ++7¶VꢀREOLJDWLRQꢀXQGHUꢀWKLVꢀZDUUDQW\ꢀGRHVꢀQRWꢀH[WHQGꢀWRꢀWKHꢀDSSOLDQFH¶VꢀFDSDELOLW\ꢀWRꢀKHDWꢀWKHꢀGHVLUHGꢀVSDFHꢁꢀ,QIRUPD-
WLRQꢀLVꢀSURYLGHGꢀWRꢀDVVLVWꢀWKHꢀFRQVXPHUꢀDQGꢀWKHꢀGHDOHUꢀLQꢀVHOHFWLQJꢀWKHꢀSURSHUꢀDSSOLDQFHꢀIRUꢀWKHꢀDSSOLFDWLRQꢁꢀ&RQVLGHU-
DWLRQꢀPXVWꢀEHꢀJLYHQꢀWRꢀDSSOLDQFHꢀORFDWLRQꢀDQGꢀFRQILJXUDWLRQꢂꢀHQYLURQPHQWDOꢀFRQGLWLRQVꢂꢀLQVXODWLRQꢀDQGꢀDLUꢀWLJKWQHVVꢀRIꢀ
ꢀWKHꢀVWUXFWXUHꢁ
This warranty is void if:
ꢀ 7KHꢀDSSOLDQFHꢀKDVꢀEHHQꢀRYHUꢃILUHGꢀRUꢀRSHUDWHGꢀLQꢀDWPRVSKHUHVꢀFRQWDPLQDWHGꢀE\ꢀFKORULQHꢂꢀIOXRULQHꢂꢀRUꢀRWKHUꢀGDPDJLQJꢀ
FKHPLFDOVꢁꢀ2YHUꢃILULQJꢀFDQꢀEHꢀLGHQWLILHGꢀE\ꢂꢀEXWꢀQRWꢀOLPLWHGꢀWRꢂꢀZDUSHGꢀSODWHVꢀRUꢀWXEHVꢂꢀUXVWꢀFRORUHGꢀFDVWꢀLURQꢂꢀEXEEOLQJꢂꢀ
FUDFNLQJꢀDQGꢀGLVFRORUDWLRQꢀRIꢀVWHHOꢀRUꢀHQDPHOꢀILQLVKHVꢁ
ꢀ 7KHꢀDSSOLDQFHꢀLVꢀVXEMHFWHGꢀWRꢀSURORQJHGꢀSHULRGVꢀRIꢀGDPSQHVVꢀRUꢀFRQGHQVDWLRQꢁ
ꢀ 7KHUHꢀLVꢀDQ\ꢀGDPDJHꢀWRꢀWKHꢀDSSOLDQFHꢀRUꢀRWKHUꢀFRPSRQHQWVꢀGXHꢀWRꢀZDWHUꢀRUꢀZHDWKHUꢀGDPDJHꢀZKLFKꢀLVꢀWKHꢀUHVXOWꢀRIꢂꢀEXWꢀ
QRWꢀOLPLWHGꢀWRꢂꢀLPSURSHUꢀFKLPQH\ꢀRUꢀYHQWLQJꢀLQVWDOODWLRQꢁꢀ
LIMITATIONS OF LIABILITY:
ꢀ 7KHꢀRZQHU¶VꢀH[FOXVLYHꢀUHPHG\ꢀDQGꢀ++7¶VꢀVROHꢀREOLJDWLRQꢀXQGHUꢀWKLVꢀZDUUDQW\ꢂꢀXQGHUꢀDQ\ꢀRWKHUꢀZDUUDQW\ꢂꢀH[SUHVVꢀRUꢀ
LPSOLHGꢂꢀRUꢀLQꢀFRQWUDFWꢂꢀWRUWꢀRUꢀRWKHUZLVHꢂꢀVKDOOꢀEHꢀOLPLWHGꢀWRꢀUHSODFHPHQWꢂꢀUHSDLUꢂꢀRUꢀUHIXQGꢂꢀDVꢀVSHFLILHGꢀDERYHꢁꢀ,QꢀQRꢀ
HYHQWꢀZLOOꢀ++7ꢀEHꢀOLDEOHꢀIRUꢀDQ\ꢀLQFLGHQWDOꢀRUꢀFRQVHTXHQWLDOꢀGDPDJHVꢀFDXVHGꢀE\ꢀGHIHFWVꢀLQꢀWKHꢀDSSOLDQFHꢁꢀ6RPHꢀVWDWHVꢀ
GRꢀQRWꢀDOORZꢀH[FOXVLRQVꢀRUꢀOLPLWDWLRQꢀRIꢀLQFLGHQWDOꢀRUꢀFRQVHTXHQWLDOꢀGDPDJHVꢂꢀVRꢀWKHVHꢀOLPLWDWLRQVꢀPD\ꢀQRWꢀDSSO\ꢀWRꢀ\RXꢁꢀ
7KLVꢀZDUUDQW\ꢀJLYHVꢀ\RXꢀVSHFLILFꢀULJKWVꢄꢀ\RXꢀPD\ꢀDOVRꢀKDYHꢀRWKHUꢀULJKWVꢂꢀZKLFKꢀYDU\ꢀIURPꢀVWDWHꢀWRꢀVWDWHꢁꢀ(;&(37ꢀ72ꢀ
7+(ꢀ(;7(17ꢀ3529,'('ꢀ%<ꢀ/$:ꢂꢀ++7ꢀ0$.(6ꢀ12ꢀ(;35(66ꢀ:$55$17,(6ꢀ27+(5ꢀ7+$1ꢀ7+(ꢀ:$55$17<ꢀ
63(&,),('ꢀ+(5(,1ꢁꢀ7+(ꢀ'85$7,21ꢀ2)ꢀ$1<ꢀ,03/,('ꢀ:$55$17<ꢀ,6ꢀ/,0,7('ꢀ72ꢀ'85$7,21ꢀ2)ꢀ7+(ꢀ
(;35(66('ꢀ:$55$17<ꢀ63(&,),('ꢀ$%29(ꢁ
4021-645C 12-29-10
Page 2 of 2
6
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
Listing and Code Approvals
1
A. Appliance Certification
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
MODELS: NNXT4236I, NNXT4236IL, NNXT3933I,
NNXT3933IL
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Fireplace Heaters
When installing above 2000 feet elevation:
STANDARD: ANSI Z21.88-2002•CSA2.33-M2002•UL307B
•
In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
•
In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
Check with your local gas utility to determine proper
orifice size.
E. Non-Combustible Materials Specification
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
F. Combustible Materials Specification
Materials made of or surfaced with wood, compressed
paper, plant fibers, plastics, or other material that can ig-
nite and burn, whether flame proofed or not, or plastered
or unplastered shall be considered combustible materials.
B. Glass Specifications
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
G. Electrical Codes
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
C. BTU Specifications
Novus
NNXT4236
NNXT3933
Max/Min Input Rate (NG)
Orifice Size (NG)
31,000/18,500
29,000/16,000
#37/.104/2.65 mm #39/.0995/2.53 mm
•
A120 VAC circuit for this product must be protected with
ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed
in locations such as in bathrooms or near sinks.
Max/Min Input Rate (LP)
Orifice Size (LP)
30,000/17,000
27,000/15,750
.061/155 mm
#52/.0635/1.62 mm
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Inspection
Note: The following requirements reference various
Massachusetts and national codes not contained in this
document.
The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector ob-
serves carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
H. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above finished grade in the area of the venting, in-
cluding but not limited to decks and porches, the following
requirements shall be satisfied:
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
•
The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition
of NFPA 54 as adopted by the Board; and
•
Product Approved side wall horizontally vented gas
fueled equipment installed in a room or structure
separate from the dwelling, building or structure used
in whole or in part for residential purposes.
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal
vented gas fueled equipment, the installing plumber or
gas fitter shall observe that a hard wired carbon mon-
oxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is
to be installed. In addition, the installing plumber or gas
fitter shall observe that a battery operated or hard wired
carbon monoxide detector with an alarm is installed on
each additional level of the dwelling, building or struc-
ture served by the side wall horizontal vented gas fueled
equipment. It shall be the responsibility of the property
owner to secure the services of qualified licensed profes-
sionals for the installation of hard wired carbon monoxide
detectors.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
•
Detailed instructions for the installation of the venting
system design or the venting system components;
and
•
A complete parts list for the venting system design or
venting system.
In the event that the side wall horizontally vented gas
fueled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
floor level.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side
wall horizontally vented gas fueled equipment does not
provide the parts for venting the flue gases, but identi-
fies “special venting systems”, the following requirements
shall be satisfied by the manufacturer:
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
•
The referenced “special venting system” instructions
shall be included with the appliance or equipment
installation instructions; and
•
The “special venting systems” shall be Product
Approved by the Board, and the instructions for that
system shall include a parts list and detailed installation
instructions.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accor-
dance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certified.
A copy of all installation instructions for all Product Ap-
proved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
Signage
A metal or plastic identification plate shall be permanently
mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with
the exhaust vent terminal for the horizontally vented gas
fueled heating appliance or equipment. The sign shall
read, in print size no less than one-half (1/2) in. in size,
“GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS”.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
8
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
User Guide
Operating Instructions
2
•
Install a physical barrier such as:
A. Gas Fireplace Safety
-
-
A decorative firescreen.
Adjustable safety gate.
WARNING
HOT SURFACES!
•
Install a switch lock or a wall/remote control with child
protection lockout feature.
Keep remote controls out of reach of children.
Never leave children alone near a hot fireplace, whether
operating or cooling down.
Teach children to NEVER touch the fireplace.
Consider not using the fireplace when children will be
present.
Glass and other surfaces are hot
during operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
•
•
•
•
• CAREFULLY SUPERVISE children in
Contact your dealer for more information, or visit: www.
hpba.org/safety-information.
same room as appliance.
• Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
flammable materials.
To prevent unintended operation when not using your
fireplace for an extended period of time (summer months,
vacations, trips, etc):
•
•
•
•
Remove batteries from remote controls.
Turn off wall controls.
Unplug 6-volt power supply and/or remove batteries.
Turn off gas controls valve on standing pilot models.
• Keep clothing, furniture, draperies and other
combustibles away.
This appliance has been supplied with an integral
barrier to prevent direct contact with the fixed glass
panel. Do NOT operate the appliance with the barrier
B. Your Fireplace
removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
WARNING! DO NOT operate fireplace before reading and
understanding operating instructions. Failure to operate
fireplace according to operating instructions could cause
fire or injury.
If you expect that small children or vulnerable adults may
come into contact with this fireplace, the following precau-
tions are recommended:
Decorative Doors
(not shown)
Section 2
Fixed Glass Assembly
Section 15
Mantel
Fan Kits
Section 2
Clear Space
Section 2
Hearth
(not required)
Figure 2.1 General Operating Parts
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
9
C. Fan Kit (optional)
F. Fixed Glass Assembly
If desired, a fan kit may be added. Contact your dealer to
order the correct fan kit.
See Section 15.D.
G. Remote Controls, Wall Controls and Wall
Switches
D. Clear Space
This appliance comes supplied with an RC200 hand-held
remote.
WARNING! DO NOT place combustible objects in front of
the fireplace or block louvers. High temperatures may start
a fire. See Figure 2.2.
•
•
Refer to Section 13.G. for operating instructions.
Other controls are available. See your dealer for full
details.
Avoid placing candles and other heat-sensitive objects on
mantel or hearth. Heat may damage these objects.
Figure 2.2 Clear Space
E. Decorative Doors and Fronts
WARNING! Risk of Fire! Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts may cause fireplace to overheat.
This fireplace has been supplied with an integral barrier to
prevent direct contact with the fixed glass panel. DO NOT
operate the fireplace with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install
one.
For more information refer to the instructions supplied
with your decorative door or front.
10
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
H. IPI Battery Tray/Battery Installation
MODULE
The IntelliFire PlusTM system has a battery backup option.
Battery longevity and performance will be affected by the
service temperatures of this appliance.
NOTICE: Batteries should only be used as a power source
in the event of an emergency such as an outage.
I. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 2.3.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, battery installation, fuel conversion,
and in the event that the control goes into LOCK-OUT
mode as a result of an error code.
NG/LP SETTING
WIRE LEAD FROM REGULATOR CONNECTS HERE
Figure 2.3 Control Module
ON Position: Appliance will ignite and run continuously
in the HI flame setting, with no adjustment in flame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
•
•
•
Wait five (5) minutes to allow possible accumulated gas
to clear.
Set the module selector switch to ON or REMOTE
position.
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless
remote.
Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time within a five minute
time period. Gas may accumulate in firebox. Call a quali-
fied service technician.
2. If using a wired wall switch with the module in REMOTE
mode, the flame output can be adjusted with the HI/LO
selector switch on the module. See Figure 2.3. Note
that the flame HI/LO selector switch will become inactive
once an optional remote control is programmed to the
control module. Note that the control module will always
ignite the fireplace on HI and remain so for the initial 10
seconds of operation. If the HI/LO is switched to the
LO position, the flame output will automatically drop to
the lowest setting after the flame has been established
for 10 sec. After this 10 second period, the flame can
be adjusted from HI to LO with the switch.
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the fireplace after 9 hours of continuous
operation without receiving a command from the
remote.
3. The control module has safety feature that automatically
shuts down the fireplace after 9 hours of continuous
operation without receiving a command from the remote.
4. If you intend to use both an optional wired wall switch
and the remote control to operate your fireplace, the wall
switch will override any commands given by the remote.
J. Before Lighting Fireplace
Before operating this fireplace for the first time, have a
qualified service technician:
5. Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or respond
to commands. The module will go into lock-out mode
by emitting three audible beeps, then continuously
displaying a RED/GREEN error code at its status
indicator LED.
•
Verify all shipping materials have been removed from
inside and/or underneath the firebox.
Review proper placement of logs, rockwool and/or other
decorative materials.
Check the wiring.
Check the air shutter adjustment.
Ensure that there are no gas leaks.
Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
•
•
•
•
•
•
Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section H.
•
•
Locate the module selector switch. (See Figure 2.3).
Set the module selector switch to the OFF position.
WARNING! Risk of Fire or Asphyxiation! DO NOT oper-
ate fireplace with fixed glass assembly removed.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
11
K. Lighting Instructions (IPI)
•
•
For normal use, activate/deactivate your fireplace with the wall switch or remote control.
The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the power supply. To prolong
battery life, remove them when using the power supply.
•
If your fireplace must be deactivated for serviced or an extended period of time, follow the instructions below.
FOR YOUR SAFETY
LIGHTING
READ BEFORE LIGHTING
INSTRUCTIONS (IPI)
WARNING: If you do not follow these instructions exactly, a fire
or explosion may result causing property damage, personal injury
or loss of life.
1. This appliance is equipped with an ignition
device which automatically lights the burner.
DO NOT try to light the burner by hand.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
A. This appliance is equipped with an
intermittent pilot ignition (IPI) device
which automatically lights the burn-
er. DO NOT try to light the burner by
hand.
GAS
VALVE
• If you cannot reach your gas sup-
plier, call the fire department.
B. BEFORE LIGHTING, smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
C. DO NOT use this appliance if any
part has been under water. Imme-
diately call a qualified service tech-
nician to inspect the appliance and
to replace any part of the control
system and any gas control which
has been under water.
2. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” in the Safety
Information located on the left side of this la-
bel. If you do not smell gas, go to next step.
WHAT TO DO IF YOU SMELL GAS
• DO NOT try to light any appliance.
3. To light the burner:
• DO NOT touch any electric switch; do
not use any phone in your building.
Equipped with wall switch: Turn ON/OFF switch
to ON.
Equipped with remote or wall control: Press
ON or FLAME button.
WARNING: CAUTION:
Equipped with thermostat: Set temperature to
desired setting.
Hot while in operation. DO NOT touch.
Keep children, clothing, furniture, gaso-
line and other liquids having flammable
vapors away.
DO NOT CONNECT LINE VOLT-
AGE (110/120 VAC OR 220/240
VAC) TO THE CONTROL VALVE.
4. If the appliance does not light after three tries,
call your service technician or gas supplier.
Improper installation, adjustment, al-
teration, service or maintenance can
cause injury or property damage. Re-
fer to the owner’s information manual
provided with this appliance.
TO TURN OFF
GAS TO APPLIANCE
1. Equipped with wall switch: Turn ON/OFF switch
DO NOT operate the appliance with
fixed glass assembly removed, cracked
or broken. Replacement of the fixed
glass assembly should be done by a
licensed or qualified service person.
to OFF.
This appliance needs fresh air for
safe operation and must be installed
so there are provisions for adequate
combustion and ventilation air.
Equipped with remote or wall control: Press
OFF button.
NOT FOR USE
WITH SOLID FUEL
Equipped with thermostat: Set temperature to
lowest setting.
If not installed, operated, and main- For use with natural gas and propane.
tained in accordance with the manufac- A conversion kit, as supplied by the
turer’s instructions, this product could manufacturer, shall be used to convert
expose you to substances in fuel or this appliance to the alternate fuel.
2. Service technician should turn off electric
power to the control when performing service.
fuel combustion which are known to
the State of California to cause can-
cer, birth defects, or other reproductive
Also Certified for Installation in a
Bedroom or a Bedsitting Room.
593-913G
For assistance or additional informa-
tion, consult a qualified installer, ser-
vice agency or the gas supplier.
harm.
Keep burner and control compartment
clean. See installation and operating
instructions accompanying appliance.
For additional information on operating your
Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.
Final inspection by
12
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
L. After Fireplace is Lit
Initial Break-in Procedure
•
The fireplace should be run three to four hours
continuously on high.
•
•
•
•
Turn the fireplace off and allow it to completely cool.
Remove fixed glass assembly. See Section 15.D.
Clean fixed glass assembly. See Section 3.
Replace the fixed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the fire-
place.
NOTICE! Open windows for air circulation during fireplace
break-in.
• Some people may be sensitive to smoke and
odors.
• Smoke detectors may activate.
M.Frequently Asked Questions
ISSUE
SOLUTIONS
Condensation on the glass
This is a result of gas combustion and temperature variations. As the appliance warms, this
condensation will disappear.
Blue flames
This is a result of normal operation and the flames will begin to yellow as the appliance is allowed
to burn for 20 to 40 minutes.
Odor from appliance
When first operated, this appliance may release an odor for the first several hours. This is caused
by the curing of materials from manufacturing. Odor may also be released from finishing materials
and adhesives used near the appliance. These circumstances may require additional curing
related to the installation environment.
Film on the glass
Metallic noise
This is a normal result of the curing process of the paint and logs. Glass should be cleaned within
3 to 4 hours of initial burning. A non-abrasive cleaner such as gas appliance glass cleaner may be
necessary. See your dealer.
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the
sound produced by a furnace or heating duct. This noise does not affect the operation or longevity
of the appliance.
Is it normal to see the pilot
flame burn continually?
In an IntelliFire Plus™ ignition system (IPI), the pilot flame should turn off when appliance is
turned off. Some optional control systems available with IPI models may allow pilot flame to
remain lit. In a standing pilot system the pilot will always stay on.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Maintenance and Service
3
Doors, Surrounds, Fronts
Frequency: Annually
Any safety screen or guard removed for servicing must be
replaced prior to operating the fireplace.
By: Homeowner
When properly maintained, your fireplace will give you
many years of trouble-free service. We recommend an-
nual service by a qualified service technician.
Tools needed: Protective gloves, stable work surface
•
•
Assess condition of screen and replace as necessary.
Inspect for scratches, dents or other damage and repair
as necessary.
A. Maintenance Tasks-Homeowner
Installation and repair should be done by a qualified
service technician only. The fireplace should be inspect-
ed before use and at least annually by a professional
service person.
•
•
Check that louvers are not blocked.
Vacuum and dust surfaces.
Remote Control
Frequency: Seasonally
By: Homeowner
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please call your dealer for a service ap-
pointment.
Tools needed: Replacement batteries and remote control
instructions.
More frequent cleaning may be required due to lint from
carpeting or other factors. Control compartment, burner
and circulating air passageway of the fireplace must be
kept clean.
•
•
Locate remote control transmitter and receiver.
Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
CAUTION! Risk of Burns! The fireplace should be
turned off and cooled before servicing.
•
•
Place batteries as needed in remote transmitters and
battery-powered receivers.
Place remote control out of reach of children.
Glass Cleaning
Frequency: Seasonally
By: Homeowner
If not using your fireplace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
Tools Needed: Protective gloves, glass cleaner, drop
cloth and a stable work surface.
•
•
Remove batteries from remote controls.
Unplug 6-volt power supply on IPI models.
CAUTION! Handle fixed glass assembly with care.
Glass is breakable.
•
•
•
•
Avoid striking, scratching or slamming glass
Avoid abrasive cleaners
DO NOT clean glass while it is hot
Prepare a work area large enough to accommodate fixed
glass assembly and door frame by placing a drop cloth
on a flat, stable surface.
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
•
Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
Note: Fixed glass assembly and gasketing may have
residue that can stain carpeting or floor surfaces.
•
•
•
Remove door or decorative front from fireplace and set
aside on work surface.
See Section 15.D. for instructions to remove fixed glass
assembly.
Clean glass with a non-abrasive commercially available
cleaner.
•
Verify termination cap clearance to subsequent
construction (building additions, decks, fences, or
sheds). See Section 6.
Inspect for corrosion or separation.
Verify weather stripping, sealing and flashing remains
intact.
•
•
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fireplace glass cleaner
(consult with your dealer)
•
Inspect draft shield to verify it is not damaged or
missing.
•
Carefully set fixed glass assembly in place on fireplace.
Hold glass in place with one hand and secure glass
latches with the other hand.
•
Reinstall door or decorative front.
14
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
Burner Ignition and Operation
Frequency: Annually
B. Maintenance Tasks-Qualified Service
Technician
The following tasks must be performed by a qualified
service technician.
By: Qualified Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom, flashlight, voltmeter, indexed drill bit set, and a
manometer.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
•
•
•
Verify burner is properly secured and aligned with pilot
or igniter.
By: Qualified Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
Clean off burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
Replace rockwool with new dime-size pieces. DO NOT
block ports or obstruct lighting paths. Refer to Section
15 for proper rockwool placement.
Verify batteries have been removed from battery back-
up IPI systems to prevent premature battery failure or
leaking.
Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
Inspect for lifting or other flame problems.
Verify air shutter setting is correct. See Section 15 for
required air shutter setting. Verify air shutter is clear of
dust and debris.
Inspect orifice for soot, dirt and corrosion. Verify orifice
size is correct. See Service Parts List for proper orifice
sizing.
•
•
Inspect gasket seal and its condition.
Inspect fixed glass assembly for scratches and nicks
that can lead to breakage when exposed to heat.
Confirm there is no damage to glass or glass frame.
Replace as necessary.
Verify that fixed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
•
•
•
•
•
•
Logs
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves.
•
•
Inspect for damaged or missing logs. Replace as
necessary. Refer to Section 15 for log placement
instructions.
•
•
Verify manifold and inlet pressures. Adjust regulator as
required.
Inspect pilot flame pattern and strength. See Figure 3.1
for proper pilot flame pattern. Clean or replace orifice
spud as necessary.
•
Verify correct log placement and no flame impingement
causing sooting. Correct as necessary.
•
•
Inspect thermocouple/thermopile or IPI flame sensing
rod for soot, corrosion and deterioration. Polish with fine
steel wool or replace as required.
Verify thermocouple/thermopile or IPI millivolt output.
Replace as necessary.
Firebox
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
•
Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
Replace fireplace if firebox has been perforated.
•
Control Compartment and Firebox Top
Frequency: Annually
By: Qualified Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
•
Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
•
•
Remove all foreign objects.
Verify unobstructed air circulation.
Figure 3.1 IPI Pilot Flame Patterns
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
15
Installer Guide
Getting Started
4
A. Typical Appliance System
NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not
drawn to scale. Actual product may vary from pictures in manual
Note: Dual venting configurations
ARE NOT allowed. Appliance
MUST be vented EITHER vertically
OR horizontally.
Vertical Termination Cap
(Section 10)
NOTE: An installation will have either a
vertical termination or a horizontal
termination. It will not have both (as shown).
Noncombustible Roof Flashing
maintains minimum clearance
around pipe (Section 10)
Storm Collar
(Section 10)
Vent Pipe penetrates roof preferably
without affecting roof rafters
Attic Insulation Shield (not shown) must be used
here to keep insulation away from vent pipe if
attic is insulated (Section 8)
Vent Pipe (Section 8)
Ceiling Firestop on
floor of attic (Section 8)
Horizontal Termination Cap
(Section 10)
Framing headed off in
ceiling joists (Section 8)
Framing/Header
(Section 5)
Optional Wall Switch
(Section 12)
Mantel & Mantel Leg
(Section 5 & 14)
Surround (Section 14)
Hearth Extension
(Not required)
Gas Line
(Section 12)
Figure 4.1 Typical System
16
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Design and Installation Considerations
D. Inspect Appliance and Components
Heatilator direct vent gas appliances are designed to op-
erate with all combustion air siphoned from outside of the
building and all exhaust gases expelled to the outside. No
additional outside air source is required.
•
•
•
•
•
Carefully remove the appliance and components from
the packaging.
The vent system components and decorative doors and
fronts may be shipped in separate packages.
If packaged separately, the log set and appliance grate
must be installed.
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
Read all of the instructions before starting the installation.
Follow these instructions carefully during the installation
to ensure maximum safety and benefit.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector, fire officials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• The vent system configuration to be used.
• Gas supply piping.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged, in-
complete or substitute components. Keep appliance dry.
• Electrical wiring requirements.
• Framing and finishing details.
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
• Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
• Installation and use of any damaged appliance or vent system
component.
• Modification of the appliance or vent system.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualified
service technician, service agency or your dealer.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Any such action may cause a fire hazard.
Tape measure
Pliers
Framing material
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under wa-
ter. Call a qualified service technician to inspect the appli-
ance and to replace any part of the control system and/or
gas control which has been under water.
Non-corrosive leak check solution
Phillips screwdriver
Framing square
Hammer
Gloves
Voltmeter
Plumb line
Level
Electric drill and bits (1/4 in.)
Safety glasses
Reciprocating saw
Manometer
Flat blade screwdriver
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
Caulking material (300ºF minimum continuous exposure
rating)
One 1/4 in. female connection (for optional fan).
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
17
Framing and Clearances
5
NOTICE: Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
A. Select Appliance Location
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out
of traffic and away from furniture and draperies.
1 in. (25 mm)
D
min. pipe to
combustibles
B
1/2 in. (13 mm) min.
C
1/2 in. (13 mm)
appliance to
min. appliance
to combustibles
combustibles
A
Drywall
48 in.
(1219 mm)
maximum
G
B
Alcove
Installation
D
A
A
Rear vent
One 45° elbow
Horiz Term
Top Vent
One 90° elbow
Horiz Term
In addition to these framing dimensions, also reference the
following sections:
• Clearances and Mantel Projections (Sections 3.C. and 3.D.)
• Vent Clearances and Framing (Section 6)
No elbows
Rear Vent
Rear Vent
One 90° elbow
Vert Term
Horiz Term
A
Two 90° elbows
Horiz Term
A
A
E
F
C
1 in. (25 mm)
min. pipe to
combustibles
F
E
Model
A
B
C
D
E
F
G
in.
mm
in.
39
991
42
35-1/2
902
37-5/8
956
19-5/8
498
19-5/8
498
43-3/8
1102
43-3/8
1102
47
1194
47
53-1/4
1353
53-1/4
1353
40
1016
43
NNXT3933
NNXT4236
mm
1067
1194
1092
Figure 5.1 Appliance Locations
18
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
Walls, ceiling, base plate and cantilever floor of the chase
should be insulated. Vapor and air infiltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air infiltration may be an issue, the inside surfaces may
be sheetrocked and taped for maximum air tightness.
B. Construct the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should enclosed inside the chase.
NOTICE: Treatment of ceiling firestops and wall shield
firestops and construction of the chase may vary with the
type of building. These instructions are not substitutes for the
requirements of local building codes. Therefore, you MUST
check local building codes to determine the requirements
to these steps.
To further prevent drafts, the wall shield and ceiling
firestops should be caulked with caulk with a minimum of
300ºF continuous exposure rating to seal gaps. Gas line
holes and other openings should be caulked with caulk
with a minimum of 300ºF continuous exposure rating or
stuffed with unfaced insulation. If the appliance is being
installed on a cement slab, a layer of plywood may be
placed underneath to prevent conducting cold up into the
room.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
19
C. Clearances
•
•
Insulation and other materials must be secured to
prevent accidental contact.
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly on
carpeting, vinyl, tile or any combustible material other than
wood.
The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with fi replace or chimney.
Failure to maintain airspace may cause overheating and
a fire.
WARNING! Risk of Fire! Maintain specified air space
clearances to appliance and vent pipe:
•
1/2 in.
(13 mm)
Note: If the inside of the framed cavity is to be
finished, the framing dimensions must include the
finished surface. If drywall is to be attached to the
rear wall, the depth must be measured from the
drywall surface.
1/2 in.
(13 mm)
Drywall
0 in.
Combustible flooring may be installed next
to the front of the appliance.
D
Clearance to Ceiling
30 in. (762 mm)
0 in. TO LEVEL
OF STANDOFFS
B
36 in.
(914 mm)
C
0 in.
A
A
B
C
D
D
Rough Opening
(Width)
Rough Opening
(Height)
Rough Opening
(Depth)
Rough Opening
(DVP Pipe)
Rough Opening
(SLP Pipe)
Model
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
NNXT3933
NNXT4236
39
42
991
1067
34 7/8
34 7/8
886
886
19 5/8
19 5/8
498
498
10
10
254
254
9
9
229
229
Figure 5.2 Clearances to Combustibles
20
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Mantels
Note: All
measurements
in inches.
30 in. minimum
to ceiling
18
17
16
16
15
15-1/4
14
14-1/2
13-3/4
13
12
13
11
12-1/4
11-1/2
10-3/4
10
10
9
8
7
6
9-1/4
8-1/2
5
7-3/4
4
7
3
6-1/4
5-1/2
5
Measured from top of hood (in inches)
Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions
Mantel Legs or Wall Projections
Top of
Appliance
Drywall
A
B
Mantel Leg or
Perpendicular Wall
A 1 in. (25 mm) min.
to perpendicular wall
B 3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both sides of opening)
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
21
Termination Locations
6
A. Vent Termination Minimum Clearances
WARNING
A
B
6 in. (minimum) up to 20 in.
152 mm/508 mm
18 in. minimum
457 mm
Fire Risk.
Maintain vent clearance to combustibles as
specified.
20 in. and over
0 in. minimum
• DO NOT pack air space with insulation or other
materials.
Gas, Wood or Fuel Oil
Termination Cap
Failure to keep insulation or other materials away
from vent pipe may cause overheating and fire.
B
Horizontal
overhang
A *
20 in.
24 in. min.
(610 mm)
(508 mm)
Vertical
wall
Gas
Termination
Cap **
Lowest
Discharge
Opening
Termination
Cap
X
Storm Collar
12
Roof
Flashing
Roof Pitch
is X / 12
*
If using decorative cap cover(s), this distance may need to be
increased. Refer to the installation instructions supplied with the
decorative cap cover.
H (min.) - Minimum height
from roof to lowest
discharge opening.
In a staggered installation with both gas and wood or fuel oil
terminations, the wood or fuel oil termination cap must be
higher than the gas termination cap.
**
Figure 6.2 Multiple Termination Caps
Roof Pitch
H (Min.) Ft.
Roof Pitch
H (Min.) Ft.
Flat to 6/12
1.0*
Over 11/12 to 12/12
Over 12/12 to 14/12
Over 14/12 to 16/12
Over 16/12 to 18/12
Over 18/12 to 20/12
Over 20/12 to 21/12
4.0
5.0
6.0
7.0
7.5
8.0
Over 6/12 to 7/12
Over 7/12 to 8/12
Over 8/12 to 9/12
Over 9/12 to 10/12
1.25*
1.5*
2.0*
2.5
Over 10/12 to 11/12 3.25
* 3 ft. minimum in snow regions
Figure 6.1 Minimum Height From Roof To Lowest Discharge
Opening
22
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
H
D
O
E
N
V
V
C
B
L
B
B
V
Fixed
Closed
G
V
V
V
Fixed
Closed
Openable
V
V
F
B
J
X
M
B
V
V
K
X
I
A
V
A
GAS METER
V
TERMINATION CAP
X
AIR SUPPLY INLET
RESTRICTION ZONE
(TERMINATION NOT
ALLOWED)
Measure vertical clearances
from this surface
Q
P
W
V
S
R
U
U
Electrical
Service
V
V
T
D*
V
Covered Alcove
Applications
Measure horizontal clearances
from this surface.
Clearances to Electrical Service
Dimension Descriptions
P 6” - Non-vinyl sidewalls
12” – Vinyl sidewalls
A Clearance above the ground, a veranda, porch, deck or balcony - 12 in.
(30 cm) minimum. *
Q 18” – Non-vinyl soffit and overhang
42” – Vinyl soffit and overhang
R 8 ft.
B Clearance to window or door that may be opened – 10,000 BTUs or less,
6 in. (15 cm) minimum; 10,000-50,000 BTUs, 9 in. (23 cm) minimum;
over 50,000 BTUs, 12 in. (30 cm) minimum. *
C Clearance to permanently closed window – 12 in. (30 cm) minimum
- recommended to prevent condensation on window.
S min
T max
1 cap
2 caps
3 ft
6 ft
2 x S actual
1 x S actual
2/3 x S actual
1/2 x S actual
D Vertical clearance to ventilated soffit located above the termination within
a horizontal distance of 2 ft (60 cm) from the centerline of the termination
– 18 in. (46 cm) minimum. **
3 caps
9 ft
E Vertical clearance to unventilated soffit - 12 in. (30 cm) minimum. **
F Clearance to outside corner - 6 in. (15 cm) minimum.
G Clearance to inside corner - 6 in. (15 cm) minimum.
4 caps
12 ft
S
min = # term caps x 3
T max = (2/# term caps) x S (actual)
H Not to be installed above a meter/regulator assembly within 3 ft (90 cm)
horizontally* from the center line of the regulator (Canada only)
U 6” min. – Clearance from sides of electrical service.
W 12” min. – Clearance above electrical service.
I
Clearance to service regulator vent outlet – 3 ft (.91 m) U.S. minimum
and 3 ft (.91 m) Canada minimum. *
* As specified in CGA B149 Installation Codes
J Clearance to non-mechanical air supply inlet into building or the
combustion air inlet to any other appliance – 9” (23 cm) U.S. minimum
and 12 in. (30 cm) Canada minimum. *
Note: Local codes or regulations may require different clearances.
** Clearance required to vinyl soffit material – 30 in. (76 cm) minimum.
K Clearance to mechanical air supply inlet - 3 ft (.91 m) U.S. minimum and
6 ft (1.8 m) Canada minimum. *
Note: Location of the vent termination must not interfere with access to
the electrical service.
L Clearance above a paved sidewalk or paved driveway located on public
property - 7 ft (2.1 m) minimum.
A vent may not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings.
WARNING!
In the U.S.: Vent system termination is NOT permitted in screened
porches. You must follow side wall, overhang and ground clearances as
stated in the instructions.
M Clearance under veranda, porch, deck or balcony - 12 in. (30 cm)
minimum. * Recommended 30 in. (76 cm) for vinyl or plastic.
Only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the floor. *
In Canada: Vent system termination is NOT permitted in screened
porches. Vent system termination is permitted in porch areas with two
or more sides open. You must follow all side wall, overhang and ground
clearances as stated in the instructions.
N Vertical clearance between two horizontal termination caps – 12 in. (30
cm) minimum.
Hearth & Home Technologies assumes no responsibility for the improper
performance of the appliance when the venting system does not meet
these requirements.
O Horizontal clearance between two horizontal termination caps – 12 in.
(30 cm) minimum.
Figure 6.3 Minimum Clearances for Termination
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
23
Vent Information and Diagrams
7
A. Approved Pipe
This appliance is approved for use with Hearth & Home
Technologies DVP and/or SLP venting systems. Refer to
Section 17.B. for vent component information.
Vertical
DO NOT mix pipe, fittings or joining methods from differ-
ent manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
8-1/2 in.
WARNING! Risk of Fire or Asphyxiation. This appliance
requires a separate vent. DO NOT vent to a pipe serving a
separate solid fuel burning appliance.
Horizontal
B. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run.
Figure 7.1 Using Two 45° Elbows
Symbol
Description
First section (closest to appliance) of vertical length
V1
Effective Height/Length
Second section of vertical length
V2
H1
H2
mm
Pipe
DVP4
DVP6
inches
4
6
102
152
First section (closest to appliance) of horizontal length
Subsequent sections of horizontal length
Effective
Height/Length
DVP12
DVP24
DVP36
DVP48
DVP6A
DVP12A
12
24
36
48
3 - 6
3 - 12
305
610
914
1219
76 - 152
76 - 305
C. Use of Elbows
Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 7.1).
DVP Pipe
(see chart)
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A
length of straight pipe is allowed between two 45º elbows
(see Figure 7.1).
Effective Height/Length
mm
Pipe
SLP4
SLP6
inches
4
6
102
152
Effective
Height/Length
SLP12
SLP24
SLP36
SLP48
SLP6A
SLP12A
12
24
36
48
2 - 6
2 - 12
305
610
914
1219
51 - 152
51 - 305
D. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.
SLP Pipe
(see chart)
•
Pipe measurements are shown using the effective length
of pipe (see Figure 7.2).
Figure 7.2 Pipe Effective Length
•
Horizontal terminations are measured to the outside
mounting surface (flange of termination cap) (see
Figure 6.4.).
•
•
Vertical terminations are measured to bottom of
termination cap.
Horizontal pipe installed level with no rise.
24
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
E. Vent Diagrams
Note: The NNXT series appliances can adapt to
SLP series vent pipe when venting off the top of
the appliance. You must use a DVP-SLP24 adapter
which can only be attached to the appliance starting
collar.
To replace the first starter elbow with two 45° elbows,
refer to Figure 7.4. All other 90° elbows can be replaced
with two 45° elbows.
General Rules:
When looking at horizontal termination diagrams, the
adapter is not counted as part of the minimum vertical
•
•
•
SUBTRACT 3 ft. from the total H measurement for each
90° elbow installed horizontally.
SUBTRACT 1-1/2 ft. from the total H measurement for
each 45° elbow installed horizontally.
A maximum of three 90° elbows (or six 45° elbows)
may be used in any vent configuration. Some elbows
may be installed horizontally. See Figure 7.8.
Elbows may be placed back to back anywhere in the
system as long as the first 90° elbow is a starter elbow
except as shown in Figure 7.4.
(V min.) requirements.
1
Whether horizontal or vertical termination, the adapter is
counted as part of the maximum vertical limitations.
All venting rules for the vent run must still be followed.
HORIZONTAL EXAMPLE
•
•
•
•
When penetrating a combustible wall, a wall shield
firestop must be installed.
When penetrating a combustible ceiling, a ceiling
firestop must be installed.
Horizontal runs of vent do not require vertical rise;
horizontal runs may be level.
V1 = 1 ft.
H1 = 11 ft.
max.
DVP
1. Top Vent - Horizontal Termination
One Elbow
V1 = 1 ft.
H1 = 11 ft.
max
DVP-SLP24
V1
H1
SLP
VERTICAL EXAMPLE
V1 min.
V1 max.
H1 max.
ft
0
m
ft
-
m
ft
m
0.00
-
-
-
-
-
-
2
0.61
1.22
1.83
3.35
5.18
5.18
5.18
5.18
0.33 0.10
-
4
0.5
1
0.15
0.30
0.46
0.61
-
6
DVP-SLP24
Adapter
12 ft (3.66 m) min.
60 ft (18.29 m) max.
12 ft (3.66 m) min.
60 ft (18.29 m) max.
-
11
17
17
1.5
2
-
-
DVP
SLP
25
23
7.62 17
7.01 17
You may install the elbow directly on top
of the appliance (DVP only).
DVP
SLP
Figure 7.3
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
25
1. Top Vent - Horizontal Termination - (continued)
Two 45° Elbows replacing One 90° Elbow
4 ft min.
(1.22 m)
17 ft max.
(5.18 m)
Figure 7.4
V1 min.
V1 max.
H1+H2 max. H1+H2+H3 max.
Two Elbows
ft
m
ft
m
ft
m
ft
m
0.5
1
0.15
0.30
0.46
0.61
-
-
6
1.83
3.35
5.18
5.18
5.18
5.18
-
-
-
-
-
11
17
17
17
17
11
17
17
17
17
3.35
5.18
5.18
5.18
5.18
1.5
2
-
-
-
DVP
SLP
25
23
7.62
7.01
Installed
Vertically
H3
Installed
Horizontally
V1
H1
H2
H2
Figure 7.5
26
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Top Vent - Horizontal Termination - (continued)
V1 min.
V1 + V2 max. H1+H2 max.
Three Elbows
ft
m
ft
m
ft
m
DVP
SLP
1
1
0.30
0.30
24
22
7.32
6.71
17
17
5.18
5.18
Installed
Vertically
H2
V2
V1
H1
Figure 7.6
2. Top Vent - Vertical Termination
No Elbow
Install Top Vent Flue Visor - No Elbow Configura-
tions
•
Remove the refractory retainer from one side
refractory.
Remove lower
refractory retainer
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Figure 7.7a Remove Refractory Retainer from one Side
Figure 7.7
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
27
•
Remove the side refractory:
•
•
Remove two screws from firebox top.
Using these screws and the same holes, install the top
vent flue baffle.
-
-
Gently raise the front of the top refractory.
Lift the side piece up slightly and then out.
-
The flue baffle will be turned to install below the level
of the firebox top for 12-30 ft vertical runs of vent.
See Figure 7.7d.
Lift top refractory
and hold in place
-
The flue baffle will be turned to install inside the flue
for vertical vent runs of 31-60 ft. See Figure 7.7e.
Pull side refractory
forward & out
Place flue visor,
reinsert screws
Figure 7.7b Remove Side Refractory
•
Remove top refractory:
-
-
Lower towards side removed in previous step.
Gently twist out.
Figure 7.7d 12-30 ft Vertical Run
Lower & twist; pull out
Place flue visor,
reinsert screws
Figure 7.7c Remove Top Refractory
Figure 7.7e 31-60 ft Vertical Run
•
Reinstall Refractory:
-
-
Replace top refractory.
Lift top refractory and slide side refractory back into
position.
-
Replace bottom retainer.
28
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Top Vent - Vertical Termination - (continued)
Three Elbows
Maximum horizontal run is
100% of vertical, but cannot
exceed 17 ft (5.18 m)
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Figure 7.8
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
29
2. Top Vent - Vertical Termination - (continued)
Two Elbows
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Maximum horizontal
run is 100% of
vertical, but cannot
exceed 17 ft (5.18 m)
Figure 7.9
30
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Rear Vent - Horizontal Termination
No Elbow
18 in. (457 mm) max.
Figure 7.10
One 45° Elbow
18 in. (457 mm) max.
Figure 7.11
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
31
3. Rear Vent - Horizontal Termination - (continued)
H1 max.
V1 min.
H1+H2 max.
Two Elbows
ft
0
2
4
6
8
8
8
m
ft
1
1
2
3
4
5
6
m
ft
m
0
0.30
0.30
0.61
0.91
1.22
1.52
1.83
3
3
0.91
0.91
1.83
2.74
3.66
4.57
5.49
0.61
1.22
1.83
2.44
2.44
2.44
6
9
12
15
18
V1
H2
H1
Figure 7.12
H1 max.
V1 min.
H1+H2+H3 max.
Three Elbows
ft
0
2
4
6
8
8
8
m
ft
1
1
2
3
4
5
6
m
ft
3
m
0
0.30
0.30
0.61
0.91
1.22
1.52
1.83
0.91
0.91
1.83
2.74
3.66
4.57
5.49
0.61
1.22
1.83
2.44
2.44
2.44
3
6
9
12
15
18
Installed
Horizontally
V1
H2
H3
H1
Figure 7.13
32
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Rear Vent - Vertical Termination
One Elbow
0 min.
6 ft (1.83 m) max.
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Figure 7.14
Two Elbows
0 min.
6 ft (1.83 m) max.
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Maximum horizontal
run is 100% of
vertical, but cannot
exceed 18 ft (5.49 m)
Figure 7.15
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
33
4. Rear Vent - Vertical Termination - (continued)
Three Elbows
0 min.
6 ft (1.83 m) max.
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Maximum horizontal run is
100% of vertical, but can-
not exceed 18 ft (5.49 m)
Figure 7.16
34
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
Vent Clearances and Framing
8
A. Pipe Clearances to Combustibles
WARNING! Risk of Fire! Maintain air space clearance to
vent. DO NOT pack insulation or other combustibles:
B. Wall Penetration Framing
Combustible Wall Penetration
Whenever a combustible wall is penetrated, you must
frame a hole for the wall shield firestop(s). The wall shield
firestop maintains minimum clearances and prevents cold
air infiltration.
•
•
•
Between ceiling firestops
Between wall shield firestops
Around vent system
Failure to keep insulation or other material away from
vent pipe may cause over heating and fire.
•
•
•
The opening must be framed on all four sides using the
same size framing materials as those used in the wall
construction.
SLP pipe -Awall shield firestop must be placed on each
side of an interior wall. A minimum 1 1/2 in. (38 mm)
overlap of attached heat shields must be maintained.
DVP pipe - A wall shield firestop is required on one side
only on interior walls. If your local inspector requires a
wall shield firestop on both sides, then both wall shield
firestops must have a heat shield attached to them.
See Section 10.L. for information for regarding the
installation of a horizontal termination cap.
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm).
• DVP heat shield - designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184
mm) thick.
•
If wall thickness is less than 4 in. the existing heat shields must be field trimmed.
If wall thickness is greater than 7-1/4 in. an extended heat shield will be required.
• SLP heat shield - designed to be used on a wall 4-3/8 in. to 7-5/8 in. (111 mm to 194
mm thick).
•
If wall thickness is less than 4-3/8 the existing heat shields must be field trimmed.
If wall thickness is greater than 7-5/8 in. an extended heat shield will be required.
(DVP Pipe Shown)
•
Heat
Shield
3 in. (76 mm)
top clearance *
Heat
Non-Combustible Wall Penetration
3 in. (76 mm)
top clearance
If the hole being penetrated is surrounded by non-combus-
tible materials such as concrete, a hole with diameter one
inch greater than the pipe is acceptable.
Shield
1 in. (25 mm)
clearance around
vertical sections
Whenever a non-combustible wall is penetrated, the wall
shield firestop is only required on one side and no heat
shield is necessary.
1 in. (25 mm)
clearance
bottom & sides
Wall
Shield
Firestop
WALL
10 in.
Vent framing hole.
3 in. (76 mm)
top clearance *
Heat
Shield
DO NOT PACK WITH
INSULATION OR
OTHER MATERIAL.
12 in.
Heat
Shield
1 in. (25 mm)
clearance
bottom & sides
The center of the
framing hole is
1 in. (25mm) above
the center of the
horizontal vent pipe.
Wall
Shield
Firestop
WALL
* When using SLP pipe, minimum clearances from the vent pipe to combustible materi-
A*
B*
als at inside wall firestops are:
Top: 2-1/2 in. (64 mm)
Bottom: 1/2 in. (13 mm)
Sides: 1 in. (25 mm)
Framing should be
constructed of 2 X 4
lumber or heavier.
Figure 8.1 Horizontal Venting Clearances To Combustible
Materials
* To center of pipe.
A
B
Top Vent Rear Vent
Model
in.
39-1/2
1003
23-1/2
597
NNXT4236
NNXT3933
mm
Figure 8.2 Wall Penetration
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
35
C. Install the Ceiling Firestop
A ceiling firestop MUST be used between
floors and attics.
•
DVP pipe only - Frame an opening 10 in.
by 10 in. (254 mm by 254 mm) whenever
the vent penetrates a ceiling/floor (see
Figure 8.3).
ATTIC ABOVE
•
SLP pipe only - Frame opening 9 in. x
9 in. (229 mm x 229 mm) whenever the
vent penetrates a ceiling/floor (see Figure
8.3).
A
•
•
Frame the area with the same sized lumber
as used in ceiling/floor joist.
The ceiling firestop may be installed above
or below the ceiling joists when installed
with a attic insulation shield. It must be
under joists between floors that are not
insulated. Refer to Figure 8.4.
•
Secure with three fasteners on each side.
A
WARNING! Risk of Fire! DO NOT pack insu-
lation around the vent. Insulation must be kept
back from the pipe to prevent overheating.
A
PIPE
DVP
SLP
10 in. (254 mm)
9 in. (229 mm)
Figure 8.3 Installing Ceiling Firestop
Install attic insula-
tion shields before
or after installation
of vent system.
3 fasteners
per side
Ceiling firestop
installed below ceiling.
Ceiling firestop
installed above ceiling.
Figure 8.4 Installing the Attic Shield
36
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
D. Install Attic Insulation Shield
WARNING! Fire Risk. DO NOT allow loose materials or
insulation to touch vent. Hearth & Home Technologies Inc.
requires the use of an attic shield.
The National Fuel Gas Code ANSI Z223.1 and NFPA 54
requires an attic shield constructed of 26 gauge minimum
metal that extends at least 2 in. (51 mm) above insulation.
Attic shields must meet specified clearance and be se-
cured in place.
Bend all tabs inward
90° to maintain
clearance and
Insert 3
screws
Flat Ceiling Installation
Bend 4 tabs
inward 90°
to maintain
clearance
prevent insulation
from falling inside
•
Remove one shield from box.
NOTICE: Cut previously installed batt insulation to make
room for the attic insulation shield.
•
•
•
•
Wrap shield around pipe if pipe is already installed in
area to be insulated.
Match the three holes in each side and fasten with three
screws to form a tube.
Bend three tabs on the bottom of the shield outward to
allow attachment to the ceiling firestop.
Bend the remaining bottom tabs inward 90° to maintain
the air space between the pipe and the shield. Set the
shield on the ceiling firestop and attach to the firestop.
Bend all tabs inward 90° around the top of the shield.
These tabs must be used to prevent blown insulation
from getting between the shield and vent pipe, and to
maintain air space clearance.
Figure 8.5 Attic Insulation Shield
•
Vaulted Ceiling Installation
•
Remove one shield from box.
NOTICE: Cut previously installed batt insulation to make
room for the attic insulation shield.
•
Cut the attic insulation shield (if application is for vaulted
ceiling) to fit your ceiling pitch. Snip cut edge to recreate
1 in. bend tabs all the way around the bottom.
Wrap shield around pipe if pipe is already installed in
area to be insulated.
Match the three holes in each side and fasten with three
screws to form a tube.
Bend three tabs on the bottom of the shield outward to
allow attachment to the ceiling firestop.
Bend the remaining bottom tabs inward 90° to maintain
the air space between the pipe and the shield. Set
the shield on the ceiling firestop and attach to the
firestop.
•
•
•
•
•
Bend all tabs inward 90° around the top of the shield.
These tabs must be used to prevent blown insulation
from getting between the shield and vent pipe, and to
maintain air space clearance.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
37
Appliance Preparation
9
•
Fold the center parts of the retaining band up and use
to remove the vent cap.
A. Top Vent
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during installa-
tion. Sheet metal edges are sharp.
NOTICE: Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
•
Remove the cover plate by removing the four screws
holding it to the top of the appliance. Remove and discard
the cover plate.
Figure 9.4
•
Discard the vent cap, remove and discard the insulation
basket.
Note: Once the vent cap has been removed it cannot
be reattached.
Figure 9.1
•
Remove the center insulation plug.
Figure 9.5
•
Snap the first vent section into place.
Figure 9.2
•
Cut the metal retaining band and fold the sides out.
Figure 9.3
38
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Rear Vent
NOTICE: Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
•
Discard the vent cap, remove and discard the insulation
basket.
•
Fold the tabs toward the center of the vent cap (90º) and
remove the insulation gasket.
Figure 9.9
Figure 9.6
•
Attach the first vent section (it will snap into place). Slide
the insulation gasket onto the vent section, up against
the appliance and over the tabs.
•
Cut the metal retaining band and fold the sides out.
Figure 9.7
Figure 9.10
•
Fold the center parts of the retaining band out and use
to remove the vent cap.
Figure 9.8
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
39
C. Secure and Level the Appliance
WARNING! Risk of Fire! Prevent contact with:
•
•
•
Sagging or loose insulation
Insulation backing or plastic
Framing and other combustible materials
Block openings into the chase to prevent entry of
blown-in insulation. Make sure insulation and other
materials are secured.
DO NOT notch the framing around the appliance
standoffs.
Failure to maintain air space clearance may cause
overheating and fire.
The diagram shows how to properly position and secure
the appliance (see Figure 9.11). Nailing tabs are provided
to secure the appliance to the framing members.
•
•
•
•
Bend out nailing tabs on each side.
Place the appliance into position.
Nailing Flanges
(both sides)
Keep nailing tabs flush with the framing.
Level the appliance from side to side and front to
back.
Shim the appliance as necessary. It is acceptable to use
wood shims underneath the appliance.
Secure the appliance to the framing by using nails or
screws through the nailing tabs.
Figure 9.11 Proper Positioning and Securing of an Appliance
•
•
•
Secure the appliance to the floor by inserting two screws
through the pilot holes at the bottom of the appliance.
40
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
Install Vent Pipe
10
A. Assemble Vent Sections (DVP Only)
Attach Pipe to the Firebox Assembly
Note: The end of the pipe sections with the lanced tabs will
face towards the appliance.
Attach the first pipe section to the starting collar:
•
•
•
Lanced pipe end to the starting collar
Inner pipe over inner collar
Push the pipe section until all lanced tabs snap in
place
•
Lightly tug on pipe to confirm it has locked.
Commercial, Multi-family (Multi-level exceeding
two stories), or High-Rise Applications
All outer pipe joints must be sealed with high temperature
silicone with a minimum of 300ºF continuous exposure
rating, including the slip section that connects directly to
the horizontal termination cap.
Figure 10.1 High Temperature Silicone Sealant
• Apply a bead of silicone sealant inside the female outer
pipe joint prior to joining sections. See Figure 10.1
A
Lances
• Only outer pipes need to be sealed. All unit collar, pipe,
slip section, elbow and cap outer flues shall be sealed in
this manner, unless otherwise stated.
WARNING! Risk of Fire or Explosion! DO NOT break
silicone seals on slip sections. Use care when removing
termination cap from slip pipe. If slip section seals are bro-
ken during removal of the termination cap, vent may leak.
B
Figure 10.2
Figure 10.3
Assemble Pipe Sections
Per Figure 10.2:
Note: Make sure that the seams are not aligned to prevent
unintentional disconnection.
•
•
•
•
Start the inner pipe on the lanced end of section A into
the flared end of section B.
Start the outer pipe of section A over the outer pipe of
section B.
Once both vents sections are started, push firmly until
all lanced tabs lock into place.
Lightly tug on the pipe to confirm the tabs have
locked.
It is acceptable to use screws no longer than 1/2 in. (13
mm) to hold outer pipe sections together. If predrilling
holes, DO NOT penetrate inner pipe.
CORRECT
For 90° and 45° elbows that are changing the vent
direction from horizontal to vertical, one screw minimum
should be put in the outer flue at the horizontal elbow joint
to prevent the elbow from rotating. Use screws no longer
than 1/2 in. (13 mm). If predrilling screw holes, DO NOT
penetrate inner pipe.
INCORRECT
Figure 10.4 Seams
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
41
B. Assemble Vent Sections (SLP Only)
C. Assemble Slip Sections
To attach the first vent component to the starting collars
of the appliance
WARNING! Risk of Fire or Asphyxiation! Overlap pipe
sections at least 1 1/2 in. (38 mm). Secure slip sections
with two screws which must not exceed 1/2 in. (13 mm)
in length. Use the pilot holes. Pipe could separate if not
properly joined.
•
•
•
Attach a DVP-SLP24 adapter to the starting collar of the
appliance.
Lock the vent components into place by sliding the pipe
section onto the collar.
Align the seam of the pipe and seam of collar to allow
engagement. Rotate the vent component to lock into
place. Use this procedure for all vent components. See
Figure 10.5.
•
Slide the inner flue of the slip section into the inner flue of
the pipe section and the outer flue of the slip section over
the outer flue of the pipe section. See Figure 10.6.
Slide together to the desired length.
•
•
Slide the gasket over the first vent section and place
it flush to the appliance. This will prevent cold air
infiltration. Caulk with a minimum of 300ºF continuous
exposure rating may be used to hold the part in place.
Continue adding vent components, locking each
succeeding component into place.
•
•
Ensure that each succeeding vent component is securely
fitted and locked into the preceding component.
Commercial, Multi-family (Multi-level exceeding
two stories), or High-Rise Applications
Figure 10.6 Slip Section Pilot Holes
For Installation into a commercial, multi-family (multi-level
exceeding two stories) or high-rise applications: All outer
pipe joints must be sealed with silicone with a minimum
of 300ºF continuous exposure rating, including the slip
section that connects directly to the horizontal termination
cap.
•
•
Maintain a 1-1/2 in. (38 mm) overlap between the slip
section and the pipe section.
Secure the pipe and slip section with two screws no
longer than 1/2 in. (13 mm), using the pilot holes in the
slip section. See Figure 10.7.
•
Apply a bead of silicone sealant inside the female outer
pipe joint prior to joining sections. See Figure 10.1
Only outer pipes need to be sealed. All unit collar, pipe,
slip section, elbow and cap outer flues shall be sealed
in this manner, unless otherwise stated.
•
WARNING! Risk of Fire or Explosion! DO NOT break
silicone seals on slip sections. Use care when removing
termination cap from slip pipe. If slip section seals are bro-
ken during removal of the termination cap, vent may leak.
Figure 10.7 Screws into Slip Section
2 - Rotate
•
Continue adding pipe as necessary following instructions
in “Assemble Pipe Sections.”
NOTICE: If slip section is too long, the inner and outer flues
of the slip section can be cut to the desired length.
1 - Align Seams
NOTICE: When installing a vent system with an HRC
termination cap, all pipe system joints shall be sealed using
silicone with a minimum of 300ºF continuous exposure
rating.
Figure 10.5 Adding Venting Components
• Apply a bead of silicone sealant inside the female outer
pipe joint prior to joining sections.
• Only outer pipes are sealed, sealing the inner flue is not
required.
• All unit collar, pipe, slip section, elbow and cap outer flues
shall be sealed.
42
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
D. Secure the Vent Sections
E. Disassemble Vent Sections
•
Vertical runs of DVP pipe must be supported every 8 ft.
(2.44 m) after the 25 ft. (7.62 m) maximum unsupported
rise.
•
Rotate either section (see Figure 10.10) so the seams
on both pipe sections are aligned as shown in Figure
10.11.
•
•
•
•
•
Vertical runs of SLP pipe must be supported every 8 ft.
(2.44 m).
Horizontal sections of vent must be supported every 5
ft. (1.52 m) with a vent support or plumber’s strap.
Wall shield firestops may be used to provide horizontal
support.
Vent support or plumber’s strap (spaced 120° apart)
may be used for support. See Figures 10.9 and 10.10.
SLP ceiling firestops have tabs that may be used to
provide vertical support.
•
Pull carefully to separate the pieces of pipe.
WARNING! Risk of Fire, Explosion or Asphyxi-
ation! Improper support may allow vent to sag and
separate. Use vent run supports and connect vent
sections per installation instructions. DO NOT allow
vent to sag below connection point to appliance.
Figure 10.10 Rotate Seams for Disassembly
Figure 10.8 Securing Vertical Pipe Sections
Figure 10.11 Align and Disassemble Vent Sections
Figure 10.9 Securing Horizontal Pipe Sections
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
43
F. Install Decorative Ceiling Components
(SLP only)
Level
A decorative ceiling thimble can be installed on a flat ceil-
ing through which the vent passes. The decorative ceiling
thimble is used to cover the firestop.
Cathedral ceiling
support box
•
Seal the gap between the vent pipe and firestop using
silicone with a minimum of 300ºF continuous exposure
rating to prevent cold air infiltration.
2 in. (51 mm)
minimum below
finished ceiling
•
Install the decorative ceiling thimble by sliding it up to
the ceiling and attaching it using the provided screws.
A decorative cathedral ceiling support box can be used
where vertical vent runs pass through a cathedral ceiling.
Cut hole 1/8 in. (3 mm) greater
in size than pattern of support
box as it is projected onto
roofline.
•
Use a plumb-bob to mark the center line of the venting
system on the ceiling and drill a small hole through the
ceiling and roof at this point. Locate the hole and mark
the outline of the cathedral ceiling support box on the
outside roof.
Figure 10.12
•
•
•
•
•
Remove shingles or other roof covering as necessary
to cut the rectangular hole for the support box. Cut the
hole 1/8 in. (3 mm) larger than the support box outline.
Lower the support box through the hole in the roof until
its bottom is at least 2 in. (51 mm) below the ceiling
(Figure 10.12).
Level the support box both vertically and horizontally
and temporarily tack it in place through the inside walls
into the roof sheathing.
Use tin snips to cut the support box from the top corners
down to the roof line and fold the resulting flaps to the
roof. See Figure 10.13.
Nail the flaps to the roof AFTER running a bead of non
hardening sealant between the flaps and the roof.
WARNING! Risk of Fire! Clean out ALL materials from
inside the support box and complete the vertical vent run
and termination.
Figure 10.13
44
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
G. Install Metal Roof Flashing
H. Assemble and Install Storm Collar
•
See minimum vent heights for various pitched roofs
(Figure 10.14) to determine the length of pipe to extend
through the roof.
Slide the roof flashing over the pipe sections extending
through the roof as shown in Figure 10.15.
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during installa-
tion. Sheet metal edges are sharp.
•
•
•
Connect both halves of the storm collar with two screws
(see Figure 10.16).
Horizontal
overhang
Wrap the storm collar around the exposed pipe section
closest to the roof and align brackets. Insert a bolt
(provided) through the brackets and tighten the nut to
complete the storm collar assembly (Figure 10.17). Make
sure the collar is tight against the pipe section.
Slide the assembled storm collar down the pipe section
until it rests on the roof flashing.
20 in.
24 in. min.
(508 mm)
(610 mm)
Vertical
wall
Lowest
Discharge
Opening
•
•
Termination
Cap
Caulk around the top of the storm collar (see Figure
10.24).
X
Storm Collar
12
Roof
Flashing
Roof Pitch
is X / 12
H (min.) - Minimum height
from roof to lowest
discharge opening.
Roof Pitch
H (Min.) Ft.
Roof Pitch
H (Min.) Ft.
Flat to 6/12
1.0*
Over 11/12 to 12/12
Over 12/12 to 14/12
Over 14/12 to 16/12
Over 16/12 to 18/12
Over 18/12 to 20/12
Over 20/12 to 21/12
4.0
5.0
6.0
7.0
7.5
8.0
Over 6/12 to 7/12
Over 7/12 to 8/12
Over 8/12 to 9/12
Over 9/12 to 10/12
1.25*
1.5*
2.0*
2.5
Over 10/12 to 11/12 3.25
* 3 ft. minimum in snow regions
Figure 10.16 Assembling the Storm Collar
Figure 10.14 Minimum Height From Roof To Lowest Discharge
Opening
NOTICE: Failure to properly caulk the roof flashing and pipe
seams may permit entry of water.
• Caulk the gap between the roof flashing and the outside
diameter of the pipe.
• Caulk the perimeter of the flashing where it contacts the
roof surface. See Figure 10.15.
• Caulk the overlap seam of any exposed pipe sections that
are located above the roof line.
CAULK
Figure 10.17 Assembling the Storm Collar Around the Pipe
Figure 10.15
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
45
I. Install Vertical Termination Cap
K. Heat Shield Requirements for Horizontal
Termination
•
Attach the vertical termination cap by sliding the inner
collar of the cap into the inner flue of the pipe section
while placing the outer collar of the cap over the outer
flue of the pipe section.
WARNING! Risk of Fire! To prevent overheating and fire,
heat shields must extend through the entire wall thick-
ness.
•
Secure the cap by driving three self-tapping screws
(supplied) through the pilot holes in the outer collar of the
cap into the outer flue of the pipe (see Figure 10.18).
• DO NOT remove the heat shields attached to the
wall shield firestop and the horizontal termination
cap.
• Heat shields must overlap 1-1/2 in. (38 mm) mini-
mum.
Termination Cap
There are two sections of the heat shield. One section
is factory-attached to the wall shield firestop. The other
section is factory-attached to the cap. See Figure 10.20.
If the wall thickness does not allow the required 1-1/2 in.
(38 mm) heat shield overlap when installed, an extended
heat shield must be used.
•
If the wall thickness is less than 4 in./102 mm (DVP) or
4-3/8 in./ 111 mm (SLP), the heat shields on the cap and
wall shield firestop must be trimmed. A minimum 1-1/2
in. (38 mm) overlap MUST be maintained.
Use an extended heat shield if the finished wall thickness
is greater than 7-1/4 in. (184 mm).
The extended heat shield may need to be cut to length
maintaining sufficient length for a 1-1/2 in. (38 mm)
overlap between heat shields.
(1 of three)
Brackets/
Bolts
Storm
Collar
•
•
Screws
•
•
Attach the extended heat shield to either of the existing
heat shields using the screws supplied with the extended
heat shield. Refer to “Vent Components Diagrams” in
the back of this manual.
Rest the small leg on the extended heat shield on top
of the pipe section to properly space it from the pipe
section.
Caulk
Figure 10.18
J. Install Decorative Wall Components (SLP
only)
Important Notice: Heat shields may not be field constructed.
A decorative wall thimble can be installed on an interior
wall through which the vent passes. The decorative wall
thimble is used to cover the wall shield firestop.
•
Slide the decorative wall thimble over the last section of
horizontal pipe before passing through the wall to the
outside.
•
Once the pipe section and the termination cap have
been connected, slide the wall thimble up to the interior
wall surface and attach with screws provided. See
Figure 10.19.
Figure 10.19 Wall Thimble
46
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
•
When installing a horizontal termination cap, follow
the cap location guidelines as prescribed by current
ANSI Z223.1 and CAN/CGA-B149 installation codes
and refer to Section 6 of this manual.
L. Install Horizontal Termination Cap
WARNING! Risk of Fire! The telescoping flue section
of the termination cap MUST be used when connecting
vent.
CAUTION! Risk of Burns! Local codes may require
installation of a cap shield to prevent anything or anyone
from touching the hot cap.
• 1-1/2 (38 mm) minimum overlap of flue telescoping
section is required.
Failure to maintain overlap may cause overheating and
fire.
NOTICE: For certain exposures which require superior
resistance to wind-driven rain penetration, a flashing kit and
HRC caps are available. When penetrating a brick wall, a
brick extension kit is available for framing the brick.
•
•
Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.
Flash and seal as appropriate for siding material at
outside edges of cap.
Note: When using termination caps with factory-supplied
heat shield attached, no additional wall shield firestop is
required on the exterior side of a combustible wall.
Heat Shield or
Extended
Heat Shield
Heat Shield
1-1/2 in. (38 mm) min.
overlap
Wall Shield
Firestop
Slip Section
can be extended
Inner Vent
SHEATHING
Outer Vent
EXTERIOR
INTERIOR
Vent depth from back of appliance to
outside surface of exterior wall
(see chart below)
Figure 10.20 Venting through the wall
Cap Specification Chart (depth without using additional pipe sections)
DVP-TRAPK1
DVP-TRAP1
DVP-TRAPK2
DVP-TRAP2
SLP-TRAP1
SLP-TRAP2
Top Vent Depth
Rear Vent Depth
Top Vent Depth
Rear Vent Depth
Top Vent Depth Top Vent Depth
4 3/8 to 8 3/8
4 1/2 to 6 3/8 in.
3 to 4 7/8 in.
6 7/8 to 10 7/8 in. 5 3/8 to 9 3/8 in. 2 to 3 7/8 in.
in.
NNXT Series
DVP-HPC1
DVP-HPC1
DVP-HPC2
DVP-HPC2
Top Vent Depth
Rear Vent Depth
Top Vent Depth
Rear Vent Depth
4 1/2 to 6 5/8 in.
3 to 5 1/8 in.
6 5/8 to 10 3/4 in. 5 1/8 to 9 1/4 in.
DVP-TRAP1 can adjust 1 1/2 in. (3 1/8 to 4 5/8)
DVP-TRAP2 can adjust 4 in. (5 3/8 to 9 3/8)
SLP-TRAP1 can adjust 1 5/8 in. (3 1/8 to 4 3/4)
SLP-TRAP2 can adjust 4 in. (5 1/4 to 9 1/4))
DVP-HPC1 can adjust 2 1/8 in. (4 1/4 to 6 3/8)
DVP-HPC2 can adjust 4 1/8 in. (6 3/8 to 10 1/2)
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
47
Shrouds
11
A. HHT Shrouds
•
You may install a shroud with this fireplace. See Section 17.D. for a list of UL Listed shrouds. Follow the instructions
included with these optional components
B. Field Constructed Shrouds
WARNING! Risk of Fire! Shrouds must be constructed
as specified. Improper construction may overheat chase
top.
•
Chase top shrouds may be field constructed where permitted by regional building codes.
NOTICE: Some regional codes require an agency-Listed
shroud. Consult your local building officials.
•
The following field constructed shroud designs have been tested for Hearth Technologies fireplace systems and termination
caps.
•
•
The shrouds must be constructed from a minimum .018 in. (26 ga) thick aluminized steel.
The wire mesh is optional but recommended and must be .018 in. thick minimum, 1/2 in. mesh.
Open Top Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW)
Min. Base Dims.
in
19 x 19
Min.
Top Dim.
mm
483 x 483
Min.
Top Dim.
Min. Top Dims.
in
16 x 16
mm
406 x 406
Min.
Base Dim.
Min.
Base Dim.
Figure 11.1 Open Top Shroud Dimensions
48
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
Mailbox Style Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW)
Min. Base Dims.
Min. Height
in
20 x 20
mm
508 x 508
Min. Height
in
18
Min. Base Dim
mm
457
Min.
Base Dim
Figure 11.2 Mailbox Style Shroud Dimensions
Roofed Style Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW)
Min. Base Dims.
in
20 x 20
mm
508 x 508
Min. Height
Minimum
Height
in
18
Minimum
Opening
Height
mm
458
Min. Opening Width
Min. Opening
Width
in
14
Minimum
Base Dimension
mm
356
Min. Opening Height
in
10
mm
254
Figure 11.2 Roofed Style Shroud Dimensions
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
49
Gas Information
12
A. Fuel Conversion
C. Gas Connection
•
Make sure the appliance is compatible with available
gas types.
•
Refer to Reference Section 17.A. for location of gas line
access in appliance.
•
Conversions must be made by a qualified service
technician using Hearth & Home Technologies specified
and approved parts.
•
•
Gas line may be run through knockout(s) provided.
The gap between supply piping and gas access hole
may be caulked with caulk with a minimum of 300ºF
continuous exposure rating, or stuffed with non-
combustible, unfaced insulation to prevent cold air
infiltration.
Ensure that gas line does not come in contact with outer
wrap of the appliance. Follow local codes.
Pipe incoming gas line into valve compartment.
Connect incoming gas line to the 1/2 in. (13 mm)
connection on manual shutoff valve.
B. Gas Pressure
•
Optimum appliance performance requires proper input
pressures.
Gas line sizing requirements will be determined inANSI
Z221.3 National Fuel Gas Code in the USA and CAN/
CGA B149 in Canada.
•
•
•
•
•
Pressure requirements are:
Gas Pressure
Minimum inlet pressure
Maximum inlet pressure
Manifold pressure
Natural Gas
5.0 in. w.c.
10.0 in. w.c.
3.5 in. w.c.
Propane
11.0 in. w.c.
13.0 in. w.c.
10.0 in. w.c.
WARNING! Risk of Fire or Explosion! Support control
when attaching pipe to prevent bending gas line.
•
A small amount of air will be in the gas supply lines.
WARNING! Risk of Fire or Explosion! Gas build-up dur-
ing line purge could ignite.
WARNING! Risk of Fire or Explosion! High pressure
will damage valve. Low pressure may cause explosion.
•
Purge should be performed by qualified service
technician.
•
•
Verify inlet pressures. Verify minimum pressures when
other household gas appliances are operating.
Install regulator upstream of valve if line pressure is
greater than 1/2 psig.
•
•
Ensure adequate ventilation.
Ensure there are no ignition sources such as sparks or
open flames.
Light the appliance. It will take a short time for air to purge
from lines. When purging is complete the appliance will
light and operate normally.
WARNING
WARNING! Risk of Fire, Explosion or Asphyxiation!
Check all fittings and connections with a non-corrosive
commercially available leak-check solution. DO NOT use
open flame. Fittings and connections could have loos-
ened during shipping and handling.
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
WARNING! Risk of Fire! DO NOT change valve settings.
This valve has been preset at the factory.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
Note: Have the gas supply line installed in accordance with
local codes, if any. If not, follow ANSI 223.1. Installation
should be done by a qualified installer approved and/or
licensed as required by the locality. (In the Commonwealth
of Massachusetts installation must be performed by a
licensed plumber or gas fitter).
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
When installing above 2000 feet elevation:
Note: A listed (and Commonwealth of Massachusetts
approved) 1/2 in. (13 mm) T-handle manual shut-off valve
and flexible gas connector are connected to the 1/2 in. (13
mm) control valve inlet.
•
In the USA: Reduce burner orifice 4% for each 1000 feet
above 2000 feet.
In CANADA: Reduce burner orifice 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
•
• If substituting for these components, please consult
local codes for compliance.
50
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Information
13
C. Optional Accessories Requirements
A. Wiring Requirements
•
This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies
approved accessories should be done now to avoid
reconstruction. Follow instructions that come with those
accessories.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
•
•
•
•
Wire the appliance junction box to 120 VAC. This is
required for use of optional accessories (standing pilot
ignition) or proper operation of the appliance (Intellifire
Plus™ ignition).
A120 VAC circuit for this product must be protected with
ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed
in locations such as in bathrooms or near sinks.
Low voltage and 120 VAC voltage cannot be shared
within the same wall box.
• Hearth & Home Technologies recommends that Intelli-
Fire PlusTM wireless controls be used for their features
and functionality with the IntelliFire PlusTM ignition sys-
tem.
•
A standard ON/OFF switch is compatible.
WARNING! Risk of Shock or Explosion! DO NOT wire
120V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
B. Intellifire Plus™ Ignition System Wiring
•
Wire the appliance junction box to 120 VAC for proper
operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
•
•
•
•
Refer to Figure 13.1, Intellifire Plus intermittent pilot
ignition (IPI) wiring diagram.
This appliance is equipped with an Intellifire control valve
which operates on a 6-volt system.
Plug the 6-volt DC power supply into the appliance
junction box to supply power to the unit
For battery backup protection, install four AA-cell
batteries (not included) into the battery pack before use.
Remove batteries if the fireplace will not be used for an
extended period of time.
NOTICE: Battery polarity must be correct or module damage
will occur.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
51
D. Electrical Service and Repair
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
WARNING! Risk of Shock! Label all wires prior to
disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
RC200 12V DC
(A23 X 1)
FLAME
SENSE
IGNITER
TO JUNCTION
BOX (120V)
6V DC
SUPPLY
3 PRONG 120VAC
CONTROL MODULE
I
AUX200 MODULE
S
FAN
FLAME
MODULATION
TO JUNCTION
BOX 120VAC
BATTERY PACK
6V DC
RED
BLACK
ORANGE
(PILOT)
GREEN
(MAIN)
BROWN
BROWN/RED
OPTIONAL ON/OFF
SWITCH
GROUND
Figure 13.1 RC200 Wiring Diagram
52
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
E. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli-
ance:
Romex
Connector
•
•
•
Remove the cover plate located on the outer shell - right
side (see Figure 13.2).
Install the supplied Romex™ connector in the cover
plate.
Make all necessary wire connections and reattach the
cover plate to the outer shell.
14/2WG
Cover Plate
outside firebox
If the box is being wired from the INSIDE of the appli-
ance:
Copper
•
Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 13.2).
Pull the electrical wires from outside the appliance
through this opening into the valve compartment. See
Figure 13.4.
ground attached
to GRN screw with
GRN wire
GRN wire
inside box
•
Figure 13.2 Junction Box Detail
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use with a fan, see Figure 13.3:
•
•
•
•
•
The power supply for the appliance must be brought into a switch box.
The power can then be supplied from the switch box to the appliance using a minimum of 14-3 with ground wire.
At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch as shown.
At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as shown.
Add a 1/4 in. insulated female connector to the red (switch leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector (1/4 in. male) as shown.
Switch
Minimum 14-3 AWG
with Ground
Red
Black
Black
White
Green
White
Green
Junction Box
Power
Supply
Wires
Switch Box
Knockout
Red
Figure 13.3 Junction Box Wired to Wall Switch or BC10
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
53
G. Remote Control Installation & Operations
RC200
IntelliFire Plus™ Multifunction Remote Control
Installation & Operating Instructions
Canadian Equipment Requirements
Hearth & Home Technologies disclaims any responsibility for,
This digital apparatus does not exceed the (ClassA/ Class
B) limits for radio noise emissions from digital apparatus
set out in the Radio Interference Regulations of the Cana-
dian Department of Communications. Le present appareil
numerique n’emet pas de bruits radioelectriques depas-
sant les limites applicables aux appareils numeriques (de
la class A/de la class B) prescrites dans le Reglement sur
le brouillage radioelectrique edicte par le ministere des
Communications du Canada.
and the warranty will be voided by, the following actions:
• Installation and use of any damaged system component.
• Modification of the system component.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fire hazard.
• Read, understand and follow these instructions for safe
installation and operation.
This device complies with RSS-210 of Industry and Science
Canada. Operation is subject to the following two condi-
tions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interfer-
ence that may cause undesired operation of the device.
Introduction
The RC200 multifunctional wireless control with dock-
ing station is designed to control constant pilot feature,
flame height, blower speed and to turn your gas fire-
place on and off. The RC200 remote control is only for
use with the Hearth & Home Technologies IntelliFire
Plus™ system (IPI).
Installation Precautions
This control is tested and safe when installed in accor-
dance with this installation manual. Do not install any
components that may be damaged.
Do not modify, disassemble, or substitute any of the com-
ponents included with this kit. Installation of this unit must
be done by a qualified service technician.
FCC Requirements
WARNING! Risk of Fire! Changes or modifications to
this unit not expressly approved by the party responsible
for compliance could void the user’s authority to operate
the equipment.
Placement of this remote control may affect performance.
An assessment of the space should be done prior to in-
stallation for optimum performance.
Note: This equipment has been tested and found to
comply with the limits for a Class B digital device, pur-
suant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in ac-
cordance with the instructions, may cause harmful in-
terference to radio communications. However, there is
no guarantee that interference will not occur in a partic-
ular installation. If this equipment does cause harmful
interference to radio or television reception, which can
be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by
one or more of the following measures:
Determine Location
Determine the location for the remote control. The selected
location should be in the same space as the gas fireplace
with visual sight of fireplace. The remote control must be
placed within 30 feet of the fireplace but should not be
exposed to extreme heat.
The RC200 is approved for interior installation and should
always be placed under weather resistant cover when used
in exterior applications.
• Keep remote control out of reach of children.
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit dif-
ferent from that to which the receiver is connected.
• Contact the dealer or an experienced radio TV techni-
cian for help.
54
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Close the housing door and press the power button.
The red light illuminates if the battery was properly in-
stalled. See Figure 3.
Installation of Remote Control Housing
CAUTION! Risk of Fire! DO NOT install damaged or
modified components. Warranty will be voided if damaged
or modified components are installed.
Kit components: One remote control, two #6 screws, two
wall anchors, one A23 battery and one AUX200 module (if
purchased retail).
RED LED
1. Remove remote control components from packaging.
2. Remove battery cover from the back of the remote by
sliding it down and install A23 battery.
To prevent unintended operation when not using your fire-
place for an extended period of time (summer months,
vacation, trips, etc):
• Remove battery from remote control.
Figure 3. Mounting Remote Control Housing
• Unplug switching adapter and remove back-up batteries.
3. Secure the remote control housing on a flat wall sur-
face using the two screws and wall anchors provided.
See Figure 1.
AUX200 Module Installation
• Control Module should be set in the OFF position before
any components are installed.
• Insert the 4 hole harness from the AUX200 module into
the 4 pin plug on the control module. See Figure 4.
AUX200
CABLE
Figure 4. AUX 200 module installation
Fan Installation
• Insert the 3 prong plug from the fan into the receptacle
located in the AUX200 module. See Figure 5.
Figure 1. Mounting Remote Control Housing
4. Place remote control inside housing. See Figure 2.
Figure 2. Remote in Housing
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
55
• Insert 3 prong plug fromAUX200 module into REM/AUX
receptacle of fireplace junction box.
Function Buttons
Press the POWER button to turn the fireplace
ON and OFF. The fireplace will first ignite the pi-
lot. Once the pilot flame is established the main
burner will be lit.
Press the FLAME button to adjust the flame
height. The flame height can be adjusted to 5
different settings: MAX, HIGH, MEDIUM, LOW,
MIN. Flame height will not be adjustable for first
ten seconds when fireplace is turned on. The
system remembers the previous flame height
setting and will automatically adjust to previ-
ous setting after 10 seconds.
FAN CORD
Press the FAN button to adjust the fan speed.
The FAN speed can be adjusted to 4 different
settings: HIGH, MED, LOW and OFF. The fan
has a timer built into the control module. After
the fireplace is turned ON the timer will wait for
7 minutes before turning on the fan. In addition,
the fan will remain on for 12 minutes after the
fireplace has been turned OFF. Whenever the
fan is turned ON, the FAN will start up on the
high setting for 10 seconds before adjusting to
the previous user setting.
Figure 5. Plug Fan into AUX200 Module
Programming the RC200 to the Control Module
CAUTION! Risk of burns! DO NOT program the remote
control to the control module when fireplace is hot.
• Verify the ON/OFF/REMOTE switch is in the REMOTE
position. Green LED light will blink three times and beep
once 5 seconds later when ready. See Figure 6.
• Using a small item (such as a paper clip) press and
release the learn button located near the ON/OFF/
REMOTE switch. See Figure 6.
Press the PILOT button to activate or deactivate
the constant pilot. The control module will beep
once indicating constant pilot has been activat-
ed. A double beep indicates the constant pilot
has been deactivated.
• Control module will beep once and LED will blink green
for 10 seconds.
• While the LED is blinking, press the power button on
the remote control. A double beep will come out of the
control module to indicate that it has been programmed
successfully.
NOTICE: Whenever the fireplace is cycled from OFF to
ON, the main burner will light on high for 10 seconds before
returning to the previous user setting.
NOTICE: Up to three remote controls can be programmed
into the control module. Simply press a button on the other
remote controls during the 10 second programming process
to add another remote into the system.
Setting the Child Lock
• Remove battery cover from the back of the remote by
sliding it down. Slide the child lock switch to enable or
disable the child lock feature. See Figure 7.
To clear memory in the control module, use a small item
(such as a paper clip) to press and release the LEARN
button. Control module will beep once and LED will blink
green for 10 seconds DO NOT press any buttons on the
remote during the ten seconds that the green LED blinks.
The memory will be cleared.
NOTICE: No functions will be usable until child lock feature
is disabled.
REMOTE POSITIONN
Figure 6. Programming RC200
Figure 7. Child Lock Switch
56
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
The fireplace may be manually shut down by one of the
following methods:
Power Outage
• If fireplace battery backup system IS installed at time of
power outage, fireplace operation will not be interrupted.
Turn off the control module:
• Open or remove the decorative front to access the control
module.
• If fireplace battery backup system IS NOT installed at
time of power outage, fireplace will shut off. To resume
fireplace operation, install battery backup.
• Move switch to OFF (See Figure 6).
NOTICE: Battery polarity must be correct or module
damage will occur.
Disconnect power to the control module:
• Open or remove the decorative front to access power
cord to the junction box and/or back-up batteries.
Manual Fireplace Shutoff
• Unplug the control module and/or remove back-up
batteries.
In the unlikely event that the remote wall switch malfunc-
tions and will not turn off the fireplace, call your dealer
for service assistance. In the meantime, you may choose
one of the following actions to turn off the fireplace:
Shut off gas to the control:
• Open or remove the decorative front and locate the gas
shut-off valve to the left of the gas control.
CAUTION! Risk of burns! Fireplace surfaces are hot
when operating and during cool down. Use care and wear
gloves when opening the front and accessing compo-
nents inside the fireplace.
• Rotate the valve 90 degrees to turn off gas supply.
Turn off power to the fireplace (if back-up batteries are
not installed):
• Locate house circuit breaker for fireplace.
• Turn off the circuit breaker.
Frequently Asked Questions/Troubleshooting
Symptom
Possible Cause
Batteries
Corrective Action
Verify battery is functional and installed correctly.
Remote control will not transmit
Remote control is in Child
Lock mode
Disengage Child Lock mode.
Control module is not in
“REMOTE” mode
Ensure module switch is set to REMOTE.
Control module and remote The control module will beep when it successfully receives a
control are not programmed command. If it does not beep, clear module memory and re-
Control module will not take
to each other
program wall switch.
commands from remote control
Control module is
unplugged. In case of
power outage, backup
batteries are depleted or
missing
If red LED light comes on when power button is pressed, verify
that the control module is plugged in the fireplace junction box
located in the controls area. Also verify that the batteries are
installed in the battery pack.
Fan does not turn on when fireplace
is started
The fireplace must run for seven minutes in order for the fan
to engage.
Built in time delay
Built in time delay
Fan does not turn off when fireplace
turned off
The fan will run for twelve minutes after the fireplace is turned off.
The fireplace will automatically shut down after nine hours of
continuous operation if it does not receive a command from
the remote.
Fireplace shuts down after extended
periods
Built-in timer
The fireplace cannot be turned off by remote if an external
wired wall switch is installed and in the ON position. Turn ex-
ternal wall switch to OFF.
External wired wall switch
Fireplace is on but will not shut off
with the remote control
At control module, turn off fireplace by sliding the ON/OFF/RE-
MOTE switch to OFF. Warning! Risk of Fire! Fireplace is hot.
Use caution when accessing module.
Remote control or control
module failure
Please contact your Hearth & Home Technologies
dealer with any questions or concerns.
For the location of your nearest
Hearth & Home Technologies dealer,
please visit www.fireside.com.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
57
Finishing
14
A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Mantels
Note: All
measurements
in inches.
30 in. minimum
to ceiling
18
17
16
16
15
15-1/4
14
14-1/2
13-3/4
13
12
13
11
12-1/4
11-1/2
10-3/4
10
10
9
8
7
9-1/4
6
7
8-1/2
7-3/4
5
4
3
6-1/4
5-1/2
5
Measured from top of hood (in inches)
Figure 14.1 Minimum Vertical and Maximum Horizontal Dimensions
Mantel Legs or Wall Projections
Top of
Appliance
Drywall
A
B
Mantel Leg or
Perpendicular Wall
A 1 in. (25 mm) min.
to perpendicular wall
B 3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
Figure 14.2 Mantel Leg or Wall Projections (Acceptable on both sides of opening)
58
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Facing Material
•
Metal front faces may be covered with non-combustible
materials only.
•
Facing and/or finishing materials must not interfere with
air flow through louvers, operation of louvers or doors,
or access for service.
•
•
•
Facing and/or finishing materials must never overhang
into the glass opening.
Observe all clearances when applying combustible
materials.
Seal joints between the finished wall and appliance top
and sides using a 300°F minimum sealant. Refer to
Figure 14.3.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specified in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
Non-combustible strip shipped with appliance.
DO NOT REMOVE!
May be covered with non-combustible materials only.
Finish wall material may be
combustible on sides and up to
non-combustible strip on top.
0 in.
0 in.
0 in.
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 14.3 Non-combustible Facing Diagram
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
59
Appliance Setup
15
A. Remove the Packaging
C. Remove the Shipping Materials
Remove the shrink film, corrugated top cap, bottom cap
and column protectors from the appliance. The appliance
should look as shown in Figure 15.1.
Remove the shipping materials from inside or underneath
the firebox.
D. Removing Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fixed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
DO NOT:
• Strike, slam or scratch glass
• Operate fireplace with glass removed, cracked,
broken or scratched.
Replace fixed glass assembly as a complete assembly.
•
•
Remove screen.
Pull the four (30/33/36 in. appliances) or seven (42 in.
appliance) glass assembly latches out of the groove on
the glass frame. Refer to Figure 15.4.
Figure 15.1 Appliance Unwrapped
•
Remove the glass assembly from the appliance.
B. Remove Screen Package Assembly
•
Grasp the top of the screen package and lift up to
remove. See Figures 15.2 and 15.3.
Latches
(both bottom
and top)
Glass
Assembly
Figure 15.4 Glass Assembly
E. Remove Top Log Pack
The top log pack is shipped inside the firebox. When you
remove the glass, the log pack will come out also.
Figure 15.2 Lift up on Screen Package
F. Remove Packing Material
•
Remove packing material (Figure 15.5).
Figure 15.3 Remove Screen Package
60
Figure 15.5 Remove Lytherm Pieces
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
G. Clean the Appliance
L. Assemble Logs
Clean/vacuum any sawdust that may have accumulated
inside the firebox or underneath in the control cavity.
•
Base logs have been permanently mounted on the
burner pan/hearth sheet and should not be moved.
H. Accessories
Install approved accessories per instructions included
with the accessories. Refer to Section 17.
WARNING! Rick of Fire and Electric Shock! Use ONLY
Hearth & Home Technologies-approved optional acces-
sories with this appliance. Using non-listed accessories
could result in a safety hazad and will void the warranty.
I. Place the Rockwool
Figure 15.7 Base Logs
WARNING! Risk of Explosion! Follow rockwool place-
ment instructions. DO NOT place rockwool directly over
burner ports. Replace rockwool material annually. Improp-
erly placed rockwool interferes with proper burner opera-
tion.
•
Install the left middle log by aligning the hole in the
bottom of the log with the pin on the left side of the left
bottom log.
•
•
Rockwool is shipped with this gas appliance.
Place a small amount of 1/2 in. diameter pieces (dime-
size) rockwool on the burner pan so that the rockwool
touches, but does not cover, the holes in the burner
pan (refer to Figure 15.5). This will provide the “glowing
embers” look.
•
It is not necessary to use the entire bag. Save the
remaining rockwool for future use.
J. Place the Lava Rock
See Figure 15.6.
Figure 15.8 Install Left Middle Log
•
Install the left top log by aligning the slot in the bottom
of the left top log with the left pin in the back log. The
back of the top log should set on the back log with the
tip resting on the left middle log.
Rockwool
Lava Rock &
Vermiculite
Figure 15.6 Placement of Rockwool, Lava Rock and Vermiculite
K. Place the Vermiculite
Sprinkle on top of lava rock.
Figure 15.9 Install Left Top Log
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
61
•
Install the Right middle log by aligning the slot and hole
in the bottom of the log with the two pins on the right
end of the left bottom log.
M.Replacing Fixed Glass Assembly
•
Set the glass panel on the lower two or four glass
assembly latches, ensuring the glass panel is centered
in the opening.
•
Replace glass latches. See Figure 15.4.
N. Air Shutter Setting
Air shutter setting should be adjusted by a qualified in-
staller at the time of installation.
•
•
•
The air shutter is set at the factory for minimum vertical
vent run.
Adjust air shutter for longer vertical runs. See
Figure 15.12.
Turn the thumbscrew to open and close.
Figure 15.10Instell Right Middle Log
•
Install the top right Y log by aligning the slot on the bottom
of the log with the pin on the right side of the back log.
The Y end of the log should rest on the top indent in the
right middle log and the top of the right bottom log.
Close
Open
Figure 15.12Adjusting Air Shutter
Figure 15.11 Install Top Right Y Log
62
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
O. Remove Screen Protector
Q. Install Hood
•
Cut the tape on top of the screen protector. See
Figure 15.13.
•
Locate the four screws just inside the upper section of
the appliance.
•
Open the screen protector and remove the screen. See
Figure 15.14.
•
•
Slide the hood into position uncer the screw heads.
Tighten the four screws. See Figure 15.16.
Figure 15.13Cut Packaging Tape
Figure 15.16Intalling Hood
R. Install Control Heat Shield
The control heat shield shipped in the bottom of the ap-
pliance MUST be placed over the control plate before
operating the appliance. Not doing so may result in over-
heating the controls on the plate.
Install the Control Heat Shield
•
Locate control heat shield (see Figure 15.17) and remove
from appliance.
Figure 15.14Remove Screen Protector
P. Unpackage the Hood & Floor Cover
Remove parts package from appliance as shown in Fig-
ure 5.15.
Control Heat Shield
Figure 15.17Locate Control Heat Shield
Figure 15.5 Removing Parts Package
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
63
•
•
•
Bend four legs at 90° angle as shown in Figure 15.18.
S. Install Floor Cover
Install the floor cover as shown in Figure 15.20.
Bend to a 90° angle
Figure 15.18Bend Control Heat Shield Legs
Figure 15.20Installing Floor Cover
Place over control plate so that all of the control plate is
covered and legs are on bottom pan of appliance. See
Figure 15.19.
Note: The floor cover in the bottom front of the fireplace
may be covering the UL labels. It is loose and can be
removed/replaced.
Control Heat Shield in Place
Figure 15.19Control Heat Shield - Installed
Make sure all wires are under the top of the control heat
shield and that there are no wires pinched between legs
and the bottom pan.
64
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Rotate the screen in at the bottom until it touches the
magnetic touch latches. See Figure 15.23.
Press in on the bottom of the screen until the magnetic
touch latches close. See Figure 15.24.
T. Close the Screen Assembly
•
Make sure the screen magnetic touch latches are in the
open position. See Figure 15.21.
•
Hange the screen on the shoulder screws in the columns.
See Figure 15.22.
Open
Figure 15.23Rotate the Screen Down
Figure 15.21Magnetic Touch Latch Open
Hang Screen on Shoulder Screws
Figure 15.24Press on Bottom of Screen
Figure 15.22Hang Screen
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
65
Troubleshooting
16
With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you
do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem
and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician. Con-
tact your dealer to arrange a service call by a qualified service technician.
A. Intellifire Plus™ Intermittent Ignition System
Symptom
Possible Cause
Corrective Action
1. Pilot won’t light.
The ignitor/module
makes noise, but no
spark.
A. Incorrect wiring.
Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are
connected to correct terminals on module and pilot assembly.
B. Loose connections or electrical
shorts in the wiring.
Verify no loose connections or electrical shorts in wiring from mod-
ule to pilot assembly. Verify connections underneath pilot assembly
are tight; also verify igniter and flame sense wires are not grounding
out to metal chassis, pilot burner, pilot enclosure, mesh screen if
present, or any other metal object.
C. Ignitor gap is too large.
Verify gap of igniter to right side of pilot hood. The gap should be
approximately .17 in. or 1/8 in. (3 mm).
2. Pilot won’t light,
there is no noise or
spark.
A. No power or transformer installed
incorrectly.
Verify that transformer is installed and plugged into module. Check
voltage of transformer at connection to module. Acceptable read-
ings of a good transformer are between 6.4 and 6.6 volts AC.
B. A shorted or loose connection in
wiring configuration or wiring har-
ness.
Remove and reinstall the wiring harness that plugs into module.
Verify there is a tight fit. Verify pilot assembly wiring to module. Re-
move and verify continuity of each wire in wiring harness. Replace
any damaged components.
C. Improper wall switch wiring.
D. Module not grounded.
Verify that 120/VAC power is “ON” to junction box.
Verify black ground wire from module wire harness is grounded to
metal chassis of appliance.
3. Pilot sparks, but
Pilot will not light.
A. Gas supply.
Verify that incoming gas line ball valve is “open”. Verify that inlet
pressure reading is within acceptable limits.
B. Ignitor gap is too large.
Verify gap of igniter to right side of pilot hood. The gap should be
approximately .17 in. or 1/8 in. (3 mm).
C. Module is not grounded.
D. Pilot valve solenoid
Verify module is securely grounded to metal chassis of appliance.
Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module.
If below 1.5 volts, replace module. If 1.5 volts or greater, replace
valve.
66
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
Intellifire Plus Intermittent Pilot Ignition System - (continued)
4. Pilot lights but con-
tinues to spark, and
main burner will not
ignite. (If the pilot
continues to spark
after the pilot flame
has been lit, flame
rectification has not
occurred.)
A. A shorted or loose connection in
Verify all connections to wiring diagram in manual. Verify connec-
tions underneath pilot assembly are tight. Verify flame sense or ig-
niter wires are not grounding out to metal chassis, pilot burner, pilot
enclosure or screen if present, or any other metal object.
flame sensing rod.
B. Poor flame rectification or contami- With fixed glass assembly in place, verify that flame is engulfing
nated flame sensing rod.
flame sensing rod on left side of pilot hood. Flame sensing rod
should glow shortly after ignition. With a multi-meter, verify that
current in series between module and sense lead is at least 0.14
microamps. Verify correct pilot orifice is installed and gas inlet is set
to pressure specifications. Polish flame sensing rod with fine steel
wool to remove any contaminants that may have accumulated on
flame sensing rod.
C. Module is not grounded.
Verify module is securely grounded to metal chassis of appliance.
Verify that wire harness is firmly connected to the module.
D. Damaged pilot assembly or con-
Verify that ceramic insulator around the flame sensing rod is not
cracked, damaged, or loose. Verify connection from flame sensing
rod to white sensor wire. Polish flame sensing rod with fine steel
wool to remove any contaminants that may have accumulated on
flame sensing rod. Verify continuity with a multi-meter with ohms set
at lowest range. Replace pilot if any damage is detected.
taminated flame sensing rod.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
67
Reference Materials
17
A. Appliance Dimension Diagram
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
C
Model
A
B
C
NNXT3933
in.
mm
in.
38
965
41
33
838
36
11 5/8
295
14 5/8
371
19-1/8 in.
(486 mm)
NNXT4236
mm
1041
916
11-5/8in.
(295 mm)
A
Alternative
Gas Access
Gas Line
Access
31-1/2 in.
(800 mm)
34-1/2 in.
(876 mm)
Electrical
Access
2-3/8 in.
34 in.
(60 mm)
(864 mm)
6-1/2 in.
(165 mm)
B
3 in.
(76 mm)
1-1/2 in.
(38 mm)
1-3/4 in.
(44 mm)
8 in.
(203 mm)
15-3/4 in.
(400 mm)
23-1/2 in.
(597 mm)
Figure 17.1 Appliance Dimensions
68
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Vent Components Diagrams
Effective Height/Length
4-7/8 in.
(124 mm)
mm
Pipe
DVP4
DVP6
inches
4
6
102
152
10-1/2 in.
(267 mm)
45°
Effective
DVP12
DVP24
DVP36
DVP48
DVP6A
DVP12A
12
24
36
48
3 - 6
3 - 12
305
610
914
1219
76 - 152
76 - 305
Height/Length
10-7/8 in.
(276 mm)
DVP45
DVP Pipe
45° Elbow
(see chart)
11-3/8 in.
(289 mm)
7-3/8 in.
1 in.
(25 mm)
10 in.
(254 mm)
(187 mm)
9-1/4 in.
(235 mm)
1-1/4 in.
(32 mm)
Assembled
Height: 24 in./610 mm
Diameter: 10 in./254 mm
1/2 in.
13-1/4 in.
(337 mm)
(13 mm) TYP
DVP90ST
DVP-FS
DVP-AS2
90° Elbow
Ceiling Firestop
12 in.
(305 mm)
6 in.
(152 mm)
1 in.
(25 mm)
1-1/2 in.
(38 mm)
10 in.
(254 mm)
8 in.
(203 mm)
UP
14 in.
(356 mm)
12 in.
(305 mm)
5 in.
(127 mm)
DVP-WS
Wall Shield Firestop
DVP-HVS
Vent Support
Figure 17.2 DVP Vent Components
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
69
B. Vent Components Diagrams (continued)
31 in.
(787 mm)
24-5/8 in.
(625 mm)
13-1/4 in.
(367 mm)
27-1/2 in.
(698 mm)
24-5/8 in.
(625 mm)
13-1/4 in.
(367 mm)
RF12M
RF6M
Roof Flashing Multi-pak
Roof Flashing Multi-pak
13-3/4 in.
(349 mm)
5 in.
(127 mm)
11-7/8 in.
(302 mm)
5 in.
(127 mm)
13-7/8 in.
(352 mm)
13-3/4 in.
(349 mm)
BEK
DVP-BEK2
Trap Cap Brick Extension
DVP-HPC Cap Brick Extension
11-5/8 in.
(295 mm)
12-1/8 in.
(308 mm)
7-1/8 in.
(181 mm)
5-3/4 in.
(146 mm)
COOL-ADD
Cap Shield
DVP-TRAPFL
Flashing
13-7/8 in.
(352 mm)
9-1/2 in.
(241 mm)
26 in.
(660 mm)
14 in.
(356 mm)
DVP-HSM-B
Extended Heat Shield
DRC-RADIUS
Cap Shield
Figure 17.3 DVP Vent Components
70
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Vent Components Diagrams (continued)
7-3/8 in.
(187 mm)
9 in.
(229 mm)
1-1/2 in.
(38 mm)
12-1/2 in.
(317 mm)
2-3/4 in.
(70 mm)
11-1/2 in.
(280 mm)
17-3/4 in.
(451 mm)
14 in.
(356 mm)
12-1/4 in.
(311 mm)
16 in.
(406 mm)
12 in.
PVK-80
(305 mm)
(For use with IPI and DSI appliances only.)
DVP-TB1
Basement Vent Cap
3-7/8 in.
(98 mm)
10-1/2 in.
(267 mm)
7-1/4 in.
(184 mm)
12-1/2 in.
(318 mm)
DVP-TV
Vertical Termination Cap
5-1/4 in.
(133 mm)
7-1/4 in.
(184 mm)
1 in.
(25 mm)
DVP-TVHW
(High wind)
Vertical Termination Cap
14 in.
(356 mm)
16-7/8 in.
(429 mm)
14 in.
(356 mm)
3/8 in. (10 mm)
1 in. (25 mm)
7-3/4 to 10-3/8 in.
(197 to 264 mm)
12 in.
(305 mm)
DVP-FBHT
Fire Brick Termination Cap
7-1/8 in.
(181 mm)
12-1/8 in.
(314 mm)
8-3/4 in.
(222 mm)
1-5/8 in.
(41 mm)
DVP-HPC
High Performance Cap
Figure 17.4 DVP Vent Components
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
71
B. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B
will be required.
8 in.
(203 mm)
Heat
Shield
15-1/8 in.
(384 mm)
Minimum
Effective Length
Maximum
Effective Length
Term Cap
Trap1
3-1/8 in.
79 mm
4-5/8 in.
117 mm
9-3/8 in.
238 mm
Max
Effective
Length
5-3/8 in.
137 mm
12 in.
(305 mm)
Trap2
DVP-TRAP
Horizontal Termination Cap
DVP-TRAP1
DVP-TRAPK1
DVP-TRAPK2
DVP-HPC2
DVP-TRAP2
DVP-HPC1
Figure 17.5 DVP Vent Components
72
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Vent Components Diagrams (continued)
Fillers
DVP-TRAP to DVP-HPC Side Filler Kit
8-1/8 in.
13 in.
(206 mm)
(330 mm)
15 in.
(381 mm)
DVP-HRC-SS
Effective Length
5-3/4 to 8-3/8 in.
146 to 213 mm
5-1/2 in. 8-3/8 in.
140 mm 213 mm
3°
87°
10-1/2 in.
267 mm
10-7/8 in.
276 mm
DVP-HRC-ZC-SS
Figure 17.6 DVP Vent Components
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
73
B. Vent Components Diagrams (continued)
6-1/2 in.
165 mm
6-1/2 in.
165 mm
6-1/2 in.
165 mm
8-3/4 in.
222 mm
9-1/4 in.
235 mm
6 in.
152 mm
6-5/8 in.
168 mm
6-5/8 in.
168 mm
SLP45
45° Elbow
9-7/8 in.
251 mm
SLP90-ST
90° Elbow
Effective
Height/
Length
6-1/2 in.
165 mm
Effective Height/Length
Pipe
SLP4
inches
4
mm
102
152
SLP6
6
SLP12
SLP24
SLP36
SLP48
SLP6A
SLP12A
12
305
SLP PIPE
24
610
25-3/16 in.
640 mm
36
914
48
1219
51 - 152
51 - 305
2 - 6
2 - 12
10-7/8 in.
276 mm
8-1/16 in.
205 mm
1-1/2 in.
38 mm
8-7/8 in.
225 mm
DVP-SLP24
Adapter
SLP-HVS
Horizontal Pipe
Support
8-11/16 in.
220 mm
12 in.
305 mm
8-11/16 in.
220 mm
1-1/2 in.
38 mm
12 in.
305 mm
5-1/2 in.
146 mm
SLP-WS
SLP-FS
Wall Shield Firestop
Ceiling Firestop
Figure 17.7 SLP Series Vent Components
74
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
8 in.
(203 mm)
Heat
Shield
15-1/8 in.
(384 mm)
Minimum
Effective Length
Maximum
Effective Length
Term Cap
Trap1
Max
3-1/8 in.
79 mm
4-3/4 in.
121 mm
9-1/4 in.
235 mm
Effective
Length
12 in.
(305 mm)
5-1/4 in.
133 mm
Trap2
SLP-TRAP
Horizontal Termination Cap
6-11/16 in.
(169 mm)
3-15/16 in.
(101 mm)
3-15/16 in.
(101 mm)
3-13/16 in.
(97 mm)
5-1/16 in.
(128 mm)
8 in.
(203 mm)
8-1/8 in.
(206 mm)
13 in.
(330 mm)
SL-2DVP
Adapter
15 in.
(381 mm)
26 in.
660 mm
DVP-HSM-B
SLP-HRC-SS
Extended Heat Shield
Effective Length
5-3/4 to 8-3/8 in.
146 to 213 mm
5-1/2 in. 8-3/8 in.
140 mm 213 mm
3°
87°
14-7/16 in.
367 mm
10-1/2 in.
267 mm
10-7/8 in.
276 mm
2-5/16 in.
59 mm
14-7/16 in.
367 mm
SLP-WT-BK
Wall Thimble-Black
SLP-HRC-ZC-SS
Figure 17.8 SLP Series Vent Components
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
75
B. Vent Components Diagrams (continued)
13 in.
14 in.
330 mm
356 mm
1-5/16 in.
34 mm
13 in.
330 mm
10-9/16 in.
269 mm
SLP-DCF-BK
Ceiling Firestop
Black
SLP-CCS-BK
Cathedral Ceiling
Support Box-Black
12 in.
9 in.
305 mm
12-1/2 in.
(317 mm)
(229 mm)
2-3/4 in.
(70 mm)
12-1/2 in.
318 mm
11-1/2 in.
(280 mm)
12-1/4 in.
(311 mm)
8-1/16 in.
205 mm
16 in.
(406 mm)
SLP-TVHW
Vertical
Termination Cap
PVK-80
(For use with IPI and DSI appliances only.)
10-11/16 in.
271mm
7-1/4 in.
(184 mm)
1 in.
(25 mm)
28-1/2 in.
724 mm
14 in.
(356 mm)
3/8 in. (10 mm)
1 in. (25 mm)
13-1/2 in.
343 mm
7-3/4 to 10-3/8 in.
(197 to 264 mm)
DVP-FBHT
Horizontal
SLK-SNKD
Snorkel
Termination Cap
Termination Cap
Figure 17.9 SLP Series Vent Components
76
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
NNXT3933I, NNXT4236I
C. Service Parts
Novus DV Heater IPI Appliance
Beginning Manufacturing Date: Aug 2009
Ending Manufacturing Date: ______
10
11
8
8
12
13
14
07
15
26
25
16
24
23
22
20
17
21
19
18
Log Set Assembly
7
5
1
6
4
3
2
Part number list on following page.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
77
C. Service Parts (continued)
NNXT3933I, NNXT3933IL
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for
your appliance please provide model number and serial number. All parts listed in this manual may
be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
4055-976
Log Assembly
Back Log
Y
1
2
3
SRV4055-966
SRV4055-967
SRV4055-969
SRV4055-974
SRV4055-970
SRV4055-971
SRV4055-972
SRV4055-973
25844
Bottom Right Log
Bottom Left Log
Log Assembly, Top and Middle
Middle Right Log
Top Right Log
4
5
6
Middle Left Log
Top Left Log
7
8
Intake Cover Gasket
Intake Cover Gasket
Non Combustible Board
Dry Wall Lip
9
4031-239
10
11
12
13
14
15
16
17
18
4055-895
4055-893
Hood
4055-215
Heater Baffle
4055-881
Hearth Pan
4055-874
Valve Assembly
Glass Frame Assembly
Screen Assembly
Floor Cover
Refer to valve page.
GLA4000-307
SRV4055-991
4055-274
Y
Y
Burner Assembly NG
Burner Assemlby LP
Gasket Valve Plate
Glass Latch Assembly
Magnetic Touch Latch
Junction Box
4055-882
Y
Y
19
4055-896
20
21
22
23
24
25
26
27
4055-135
Pkg of 2
33858/2
Y
Y
Y
Qry 2 req
4021-650
4021-013
Cover Plate
4031-222
Junction Box Shield
Nailing Flange
4055-888
Qty 4 req
4044-161
Back Gasket
4000-225
Cord Clip
14218
Refractory, Back
Refractory, Right Side
Refractory, Left Side
Refractory, Top
4055-856
4055-859
4055-860
4055-866
Conversion Kit NG
Conversion Kit LP
Pilot Orifice NG
Pilot Orifice LP
DCKVN-NNXT
DCKVP-NNXT
593-528
Y
Y
Y
Y
Y
Y
593-527
Regulator NG
NGK-DXV-50
LPK-DXV-50
Regulator LP
Additional service parts on following page.
78
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
C. Service Parts (continued)
NNXT4236I, NNXT4236IL
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for
your appliance please provide model number and serial number. All parts listed in this manual may
be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
4055-976
Log Assembly
Back Log
Y
1
2
3
SRV4055-966
SRV4055-967
SRV4055-969
SRV4055-974
SRV4055-970
SRV4055-971
SRV4055-972
SRV4055-973
25844
Bottom Right Log
Bottom Left Log
Log Assembly, Top and Middle
Middle Right Log
Top Right Log
4
5
6
Middle Left Log
Top Left Log
7
8
Intake Cover Gasket
Intake Cover Gasket
Non Combustible Board
Dry Wall Lip
9
4031-239
10
11
12
13
14
15
16
17
18
4055-895
4055-893
Hood
4055-215
Heater Baffle
4055-881
Hearth Pan
4055-874
Valve Assembly
Glass Frame Assembly
Screen Assembly
Floor Cover
Refer to valve page.
GLA4000-307
SRV4055-991
4055-274
Y
Y
Burner Assembly NG
Burner Assemlby LP
Gasket Valve Plate
Glass Latch Assembly
Magnetic Touch Latch
Junction Box
4055-882
Y
Y
19
4055-896
20
21
22
23
24
25
26
27
4055-135
Pkg of 2
33858/2
Y
Y
Y
Qry 2 req
4021-650
4021-013
Cover Plate
4031-222
Junction Box Shield
Nailing Flange
4055-888
Qty 4 req
4044-161
Back Gasket
4000-225
Cord Clip
14218
Refractory, Back
Refractory, Right Side
Refractory, Left Side
Refractory, Top
4055-856
4055-859
4055-860
4055-866
Conversion Kit NG
Conversion Kit LP
Pilot Orifice NG
Pilot Orifice LP
DCKVN-NNXT
DCKVP-NNXT
593-528
Y
Y
Y
Y
Y
Y
593-527
Regulator NG
NGK-DXV-50
LPK-DXV-50
Regulator LP
Additional service parts on following page.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
79
NNXT3933I, NNXT4236I
C. Service Parts
Beginning Manufacturing Date: Aug 2009
Ending Manufacturing Date: ______
#16 Ignition Control Assembly
#15 Valve Assembly
15.1
15.2
15.3
15.4
15.5
15.12
15.6
16.2
15.11
15.10
15.7
15.9
16.4
16.1
16.3
15.8
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
4055-889
2090-012
2090-013
4021-042
4055-202
4055-205
302-320A
2166-302
2166-303
303-315/5
2166-305
2166-304
4021-429
4021-512
4055-964
2166-307
4055-899
2166-325
2166-323
582-839
15.1
Pilot Shield
Pilot Assembly NG
Pilot Assembly LP
Pilot Gasket
Y
Y
15.2
15.3
15.4
15.5
15.6
Air Shutter Assembly
Valve Bracket
Y
Flex Ball Valve Assembly
Valve NG
Y
Y
Y
Y
Y
Y
15.7
Valve LP
15.8
15.9
15.10
15.11
15.12
16
Male Connector
Transformer
Pkg of 5
Wire Harness
Gasket, Bulkhead
Bulkhead W/Flex Tube
Igntion Control Assembly
Control Module
Control Plate
Y
Y
Y
16.1
16.2
16.3
16.4
AuxRC200
Y
Y
Y
Y
Battery Pack
Orifice NG (#39C)
Orifice LP (#52C)
582-852
80
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
D. Optional Components
20 in.
[508 mm]
C
17 in.
[432 mm]
9-3/8 in.
[238 mm]
D
B
A
LDS33/LDS46 Decorative Shroud
TCG375 Terra Cotta Cap
A
B
C
D
Catalog # in. mm in. mm in. mm in. mm
LDS33
LDS46
36
914
36
914 8.5 216
11
11
279
279
48 1219 72 1829 8.5 216
E
D
LDSCP-M Shroud Leg Multipack
(not shown)
C
B
A
LDS-BV Decorative Shroud
Catalog #
A
26
B
C
E
E
23
in.
12.5
318
15.5
394
22
LDS-BV
mm
660
533
584
See your Heatilator dealer for a complete listing of optional components.
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
81
E. Contact Information
Please contact your Heatilator dealer with any questions or concerns.
For the location of your nearest Heatilator dealer,
Heatilator, a brand of Hearth & Home Technologies Inc.
7571 215th Street West, Lakeville, MN 55044
- NOTES -
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating
and maintenance
instructions included.
• Read, understand and follow
these instructions for safe
installation and operation.
• Leave this manual with
party responsible for use
and operation.
This product may be covered by one or more of the following patents: (United States) 5328356, 5601073, 5613487,
5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712,
6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending.
2000-945
Printed in U.S.A. - Copyright 2012
82
Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12
Download from Www.Somanuals.com. All Manuals Search And Download.
|