CPKF
SPlit SyStem Heat PumP
Product SPecificationS
This 50-Hz split system heat pump allows for ground-
level or rooftop applications and has been tested for
optimum performance by an independent third party.
Standard Features
• Quiet operating top discharge
• Copper tube/aluminum fin coil
• Brass suction and liquid line shut-off valves with
sweat connection
• Manual reset high-pressure control
• Automatic reset low-pressure control for loss-of-charge
protection
• Totally enclosed, permanently lubricated condenser motor
• Ultra-quiet hermetically sealed compressor with internal
high-pressure control
• Bi-flow liquid line filter dryer
• Suction line accumulator
• Check flowrator expansion device
• Anti-cycling reversing valve circuit
• Crankcase heater (where indicated)
• Time-initiated, temperature-terminated defrost control
• Contactor with lug connections
• Ground lug connections
50 Hz
• CE Certified
2 to 5 ton
[7.0 kw to 17.56 kw]
Cabinet Features
• Goodman® brand sound control design
• Heavy-gauge, galvanized-steel cabinet properly reinforced
and braced
Nominal Capacity
24,000 to 60,000 BTU/h
• Steel louver coil guard
• Attractive architectural gray powder-paint finish with 500-
hour salt spray approval
• Removable access panels
Accessories
• Room thermostat with 2-stage heat/1-stage cool and
emergency heat, capability (HPT18-60)
• Automatic change-over room thermostat with 2-stage heat/
1-stage cool and emergency heat capability (HPTA18-60)
• Digital Room Thermostat for 2-stage heat/1-stage cool
(CTHP18-60HD)
SS-CPKF50
12/10
Supersedes 4/10
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
SPecificationS
CPKF24-2* CPKF36-2* CPKF36-5* CPKF42-5* CPKF48-5* CPKF60-5* CPKF61-5*
Capacities
Nominal Cooling (BTU/h)
EER¹
23,600
9.0
33,000
9.0
35,000
9.0
40,000
9.0
48,000
9.0
53,000
9.0
57,000
9.0
Nominal Heaꢀng (BTU/h)
Decibels
23,000
78
32,000
78
32,000
78
39,000
78
48,000
78
54,000
80
61,000
80
Compressor
RLA
12.2
64
17.9
97.4
5.3
42
7.4
50
9.0
65.5
9.0
74
10.9
101
LRA
Volts
220-240
220-240
380-420
380-420
380-420
380-420
380-420
Condenser Fan Motor
Horsepower
¼
¼
⅓
¼
⅓
⅓
⅓
FLA
0.9
0.9
1.2
380
0.8
380
1.2
380
1.2
380
1.2
380
Volts
220-240
220-240
Refrigeration System
Liquid Valve Size (“O.D.)
Sucꢀon Valve Size (“O.D.)
Valve Type
3/8
¾
3/8
¾
3/8
¾
3/8
⅞
3/8
⅞
3/8
⅞
3/8
⅞
Sweat
72
Sweat
110
Sweat
110
Sweat
131
Sweat
137
Sweat
138
Sweat
167
Refrigerant Charge (oz.)
Shipped with Orifice Size (in.)
Condenser Fan / Coil
Horsepower - RPM
Fan Diameter/ # Fan Blades
Outdoor Nominal CFM
Face Area (ſt²)
0.059
0.073
0.073
0.080
0.084
0.093
0.093
¼-950
20/3
1800
13.3
¼-950
20/3
1800
14.58
1/19
Ripple
24
⅓-1075
20/3
¼-950
22/3
2600
14.58
1/19
Ripple
24
⅓-1075
22/3
2600
17
⅓-1075
22/3
2600
17
⅓-1075
22/3
3200
1
1800
14.58
1/19
Rows Deep/ Fins per Inch
Fin Type
1/19
Ripple
22
1/19
Ripple
24
1/22
Ripple
36
1/22
Ripple
36
Ripple
24
Coil No. of Tubes
Coil Tube Diameter (in.)
Electrical Data
Voltage-Hz / Phase
Min. Circuit Ampacity²
Max. Overcurrent Protecꢀon ³
Min / Max Volts
0.375
0.375
0.375
0.375
0.375
0.375
0.375
220/240-50/1
380/415-50/3
12.4
16.2
23.3
7.9
10
12.4
14.8
25 amps
198/264
½ or ¾
40 amps
198/264
½ or ¾
15 amps
342/456
½ or ¾
15 amps
342/456
½ or ¾
20 amps
342/456
½ or ¾
20 amps
342/456
½ or ¾
25 amps
342/456
½ or ¾
Power Supply Conduit Size
Ship Weight (lbs-[kg])
191 (87)
206 (94)
206 (94)
213 (97)
216 (98)
248 (113)
249 (113)
¹ Energy Efficiency Raꢀo
² Wire size should be determined in accordance with Naꢀonal Electrical Codes. Extensive wire runs will require larger wire sizes.
³ Must use ꢀme-delay fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
SS-CPKF50
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf24-2m & aruf024-00*-2* / aruf17292a*
4
SS-CPKF50
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf24-2m & aruf024-00*-2* / aruf17292a* (cont.)
SS-CPKF50
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf36-2m / aruf036-00*-2*
6
SS-CPKF50
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf36-2m / aruf036-00*-2* (cont.)
SS-CPKF50
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf36-5m & aruf048-00*-2*
8
SS-CPKF50
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf36-5m & aruf048-00*-2* (cont.)
SS-CPKF50
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf42-5m & aruf048-00*-2*
10
SS-CPKF50
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf42-5m & aruf048-00*-2* (cont.)
SS-CPKF50
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf48-5m & aruf048-00*-2*
12
SS-CPKF50
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf48-5m & aruf048-00*-2* (cont.)
SS-CPKF50
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf60-5m & aruf060-00*-2*
14
SS-CPKF50
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
exPanded cooling data — cPkf60-5m & aruf060-00*-2* (cont.)
SS-CPKF50
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Product SPecificationS
ScHematic wiring diagramS
low-Voltage control wiring diagram
Component Codes
CM
Outdoor Fan Motor
COMP Compressor
C
Contactor
Defrost Control
Low-Voltage Defrost Relay
Crankcase Heater
Internal Overload
DC
LDVR
CH
IO
LP
Low-Pressure Control
High-Pressure Control
Outdoor Thermostat (Opꢀonal)
Fan Capacitor
HP
OT
FC
DFT
RVC
Defrost Thermostat
Reversing Valve Coil
HVDR High-Voltage Defrost Relay
AST
Anꢀ-Short Cycle Timer
line-Voltage Power wiring diagramS
380/415, 50 HZ, 3 PH
220/240, 50HZ, 1 PH
CPKF24-2, CPKF36-2 & CPKF48-2
CPKF36-5, CPKF48-5, CPKF60-5 & CPKF61-5
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without
notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
16