How MucH Power do you need?  
tranSfer SwitcH  
confiGurationS  
1
2
3
6
7
8
4
5
9
10  
automatic transfer Switch basic  
Whole-House Protection  
Generac offers air-cooled and liquid-cooled generators that can supply up to  
whole-house protection. in conjunction with a transfer switch, this application  
completes your power solution package (see page 8 for options).  
rtS-e models  
to accurately size liquid-cooled generators, a licensed electrician should apply  
an amp meter to the circuits and appliances to determine the load requirement  
for back up.  
2
0
0
M
A
A
M
P
C
LO  
A
A
D
N
SHEDDING  
SF TC  
AUT  
O
T
I
T
R
E
R
S
W
I
H
U
N
T
E
I
L
M
I
T
A
Y
3
S
R
E
-
R
I
V
N
I
D
C
O
E
O
D
R
I
S
C
O
N
N
E
C
T
I
N
S
I
D
E
/
O
U
T
D
O
O
R
R
A
T
E
D
Sizing Guide  
Air Cooled Generator  
5-Ton Central Air 1  
4-Ton Central Air 1  
3-Ton Central Air 1  
Well Pump or Water Heater  
Family Room  
8 kW 10 kW 14 kW 17 kW  
Circuits  
20 kW  
rtS-S models  
(50 Amp / 240V)2  
(40 Amp / 240V)2  
(30 Amp / 240V)2  
(20 Amp / 240V)2  
(20 Amp / 120V)  
(20 Amp / 120V)  
(20 Amp / 120V)  
(20 Amp / 120V)  
(20 Amp / 120V)  
(20 Amp / 120V)  
(15 Amp / 120V)  
(15 Amp / 120V)  
(15 Amp / 120V)  
(15 Amp / 120V)  
(15 Amp / 120V)  
(15 Amp / 120V)  
(15 Amp / 120V)  
Master Bedroom  
Home Office  
rtS-n models  
Media Room  
automatic transfer switch basic is rated  
nema 1. all rts-n, rts-e & rts-s  
transfer switches are nema 3r (outdoor/  
indoor) rated.  
Garage  
Kitchen (#1)3  
Kitchen (#2)3  
Bathroom  
Furnace  
note: warranty coverage is not  
available for generators that are  
used for prime power (main power  
source) in place of the existing  
utility power where utility power is  
present or in place of utility power  
where utility power service does  
not normally exist. for life support  
or critical care applications, please  
see page 6 for industrial units.  
Sump Pump  
Bedroom (#2)  
Bedroom (#3)  
Bathroom (#2)  
1 check your air conditioners starting requirements. starting requirements for older and/or less efficient equipment may exceed  
recommended generator capability. additionally, for any electrical equipment or appliances, always check the manufacturers  
power requirements. this will help to ensure standby power accommodations for items that cycle during operation.  
2 240 volt appliances require 2 circuits 3 most kitchens require multiple circuits  
for smaller central air up to 2 tons  
note: rooms and appliances indicated here are for example only. you may choose others that better reflect your needs. because of the  
cycling nature of some appliances such as refrigerators and furnaces, it may not be possible for all appliances to run simultaneously.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
air-cooled 8 – 20 kw  
GENErAC AIr-COOLED MODELS  
America’s #1 selling home standby generator  
Generac air-cooled models feature Generacs ohVi industrial  
engines for reliability and long life, and plateau honing to  
significantly decrease service intervals.  
8-17 kW  
8 kW / 10 kW / 14 kW / 17 kW MODELS (STEEL)  
Air-cooled models for essential circuit protection  
smaller air-cooled models provide essential circuit  
protection for small to medium sized homes.  
Engine horsepower strength:  
Generac ohVi® (overhead  
Valve industrial) engines  
continuous Fuel: all models run on lp gas or natural  
are specifically designed for  
generator demands. the 2-year  
oil change interval, full-pressure  
lubrication system and spin-on  
oil filter contribute to the longest  
running engine in the industry.  
gas, providing continuous power with reduced emissions.  
circuit coverage: individual models can protect  
8, 10, 12, 14, or 16 circuits in your home.  
true power™ technology for sensitive electronics:  
10-17 kw units feature an electronic governor for smooth and consistent output with less  
than 5% total harmonic distortion for sensitive electronic equipment and appliances.  
Steel Enclosures: all steel enclosures feature durable galvanneal finish which bonds  
zinc to steel for superior rust and corrosion protection.  
Composite Mounting Pad: provides for easier installation.  
ul listed: ul 2200 listing ensures the generator meets local building code approval,  
safety and certified kw power ratings.  
External dual gFcI outlet: easy access to power for outdoor equipment available on  
17 kw model.  
17-20 kW  
17 kW AND 20 kW MODELS (ALUMINUM)  
Control Panel for  
The quietest and most powerful air-cooled  
protection on the market  
10 - 20 kW air-cooled generators  
the easy-to-use control panel  
features user-friendly lcd digital  
controls, providing bilingual plain  
text display.  
these larger air-cooled models are the quietest and most  
powerful generators of their size on the market today. the  
20 kw model includes the base fascia for a finished look  
and thorough protection from debris and rodents. they  
include all the features of the 8-17 kw models above as  
well as the following:  
Quiet-test™: the patented Quiet-test low-speed  
exercise mode for up to 50% quieter weekly self-test.  
Increased circuit coverage: the 20 kw model  
provides up to whole-house protection.  
aluminum all-Weather Enclosures: all-weather corrosion resistant  
aluminum enclosures prolong the life and look of the generator. ideal for  
salt air coastal communities.  
External dual gFcI outlet: easy access to power for outdoor equipment.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
liquid-cooled 22 – 150 kw  
QT SErIES  
The quiet standard in liquid-cooled  
automatic standby power  
Quiet-Test™ feature:  
Generacs Qt series generators have redefined backup  
power for larger residential and commercial applications.  
these models feature automotive grade liquid-cooled  
engines for proven power and performance.  
reduces noise by lowering engine  
speed during the generators  
weekly self-test cycle. the ultra-  
quiet sound level is comparable  
to a car at idle, up to 50% quieter  
With outputs ranging from 22 to 150 kW, these QT models feature:  
than when the generator is  
operating under normal load.  
• Quiet-Test™: all models feature the patented Quiet-test low-speed exercise mode  
for quieter weekly self-test.  
• Durable Enclosures:  
Steel enclosures have a galvanneal paint finish which bonds zinc to steel  
for superior rust and corrosion protection.  
Aluminum enclosures are corrosion resistant and ideal for salt air  
coastal conditions.  
• Continuous Fuel: all models run on lp gas or natural gas, providing continuous  
fuel and reduced emissions.  
r-Series Controller for  
22-60 kW Liquid-cooled  
generators  
full system monitoring including  
led indicators for safety  
shutdowns, fuel pressure and  
battery voltage. integrated  
transfer switch controller for rts  
transfer switch.  
• Stable Output: clean, consistent power for sensitive electronics. ul listed.  
• Transfer Switches: matching transfer switches sold separately. rated from 100 to  
800 amps. see page 8.  
22-60 kW  
22 kW – 60 kW MODELS  
ideal for many large residential and commercial  
applications. a perfect size for small office  
buildings, churches, municipal buildings,  
retail centers, police stations, schools, farms,  
convenience stores and restaurants.  
H-100 Controller for 70 kW  
and above Liquid-cooled  
generators:  
offers quick access and  
simultaneous monitoring of key  
generator functions. integrated  
transfer switch controller for  
hts transfer switch.  
70-150 kW  
70 kW – 150 kW MODELS  
a superior solution for applications that require more  
sophisticated monitoring and diagnostic capabilities.  
applications range from supermarkets and pumping  
stations to strip malls and hotels.  
ADvANTAGES Of GASEOUS fUEL  
natural gas is delivered reliably  
and continuously underground.  
natural gas demand drops  
significantly during a power  
outage, assuring more than  
adequate supply.  
spark-ignited engines start more  
easily than diesel engines in cold  
climates. spark-ignited engines  
are also quieter in terms of noise,  
vibration and harshness.  
Gaseous fueled engines emit fewer  
pollutants than other fuels and are  
more environmentally friendly.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Modular Power SySteMS • GeMini • Bi-Fuel  
GEMINI® TWIN PACk  
fOr HIGHEST POWEr  
DENSITy  
INDUSTrIAL POWEr frOM GENErAC’S  
MODULAr POWEr SySTEMS  
for applications requiring greater amounts of standby  
when space is at a premium and  
power, the mQt100 and mQt150 models are ideal.  
reliability is critical, no other  
available through your local Generac industrial  
dealer, the output of these gensets can be combined  
to form a Generac modular power system (mps).  
mQt series modular power systems are building  
manufacturer comes close to  
Generacs Gemini twin pack.  
part of the mps family, these units  
feature two 500 kw generators inside  
blocks that link together to combine the power output  
a single, weather resistant and sound  
equal to one large single generator. with the ability to  
attenuated enclosure. the exclusive  
parallel up to ten 100 kw units or up to ten 150 kw  
units, these generators can satisfy higher end  
requirements ranging from 100 to 1500 kw.  
powermanagercontrol system  
allows for combining the output of  
large, single engine gensets with a  
significant improvement in reliability.  
• Smaller footprint than many  
comparable single engine models  
redundancy  
because each mQt generator within the system backs up the others, critical loads receive  
extra protection and building managers enjoy greater peace of mind.  
• Built-in redundancy for superior  
system reliability  
• Scalable solution – up to seven  
Gemini gensets can be paralleled  
without additional switchgear for  
up to 7,000 kw in total output  
Serviceability  
mQt generators use modified high volume truck or industrial engines that can be serviced  
using readily available, cost-effective parts. since each generator backs up the others,  
servicing can be accomplished without losing backup power to critical loads.  
• Fast production turn around –  
often within weeks  
Scalability  
a Generac modular power system can be expanded as facilities grow. there is no need  
to replace the system if future power requirements exceed projections and no need to  
over-spend on a larger system that might never be fully utilized.  
• Easily serviced with common parts  
Flexibility  
mps modules provide unmatched flexibility because they can be placed in any configuration  
side by side, end to end, together or apart. they are light enough for most rooftop  
applications and the lower weight eliminates the need for heavy-duty cranes and material  
handlers during installation.  
THE GENErAC  
INDUSTrIAL DEALEr  
NETWOrk  
BI-fUEL™  
installation, start-up and servicing of  
modular power systems require  
specialized knowledge and expertise.  
Generac industrial dealers have  
factory-trained personnel to ensure  
that your customers get the best  
possible solution, fast delivery,  
Longest run Times in the Industry  
Generac bi-fuel generators start on diesel fuel and add natural gas as load is applied.  
during an outage, they typically operate on a mixture of up to 70% natural gas and  
30% diesel fuel (contact factory for product specifications). if the natural gas supply is  
interrupted, the generator automatically switches to 100% diesel without any power drop  
during the transition.  
professional installation and start-up.  
Benefits of Bi-fuel  
if a customer needs a diesel-powered  
generator or a generator size that is  
beyond the scope of the Qt series  
line, a Generac industrial dealer can  
meet requirements up to 9,000 kw.  
• Dramatically increased run times  
• Minimal on-site fuel storage  
• Reduced fuel maintenance  
• Reduced environmental risk  
• Lower particulate and NOx emissions  
Generac industrial dealer certified  
service technicians are fully trained  
on all Qt series generators and  
can provide your customers with  
hassle-free maintenance and  
service agreements.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Portable 1800 – 17500 wattS  
Better power. More choices.  
from home use to camping, construction or outdoor events, Generac portable generators  
provide dependable portable power. power the fun stuff or cover an emergency. the wide  
range of sizes gives you flexibility to choose as much power as you need.  
• Generac OHVI® Engine*: Generacs  
original and proven overhead Valve  
industrial engines provide the longest  
running time in the industry.  
• Steel Fuel Tank: includes incorporated  
fuel gauge.  
• Low-Tone Muffler: provides quiet  
operation.  
• Electric Start*: includes starting battery.  
• Fold-Down Handles: provide easy  
portability.  
• Never-Flat Wheels: provide all-terrain  
portability.  
* see specs for available models.  
• Hour Meter*: tracks usage and includes  
maintenance resets.  
XP SerieS  
xp series  
xP SErIES: 4000 — 10000 WATTS  
the professional grade Xp series of portable generators has been engineered for high  
performance. durable construction with oversized full wrap frame tubing and impact  
resistant corners minimizes damage from rough handling. these rugged units also include:  
true Powertechnology for utility quality  
electrical output for sensitive electronics  
external battery charge Jack on  
electric start models  
low-oil Pressure Protection to protect  
engine from damage  
circuit breaker outlet Protection  
including dual breakers on  
120/240V outlets  
covered outlets for more protection from the  
environment  
cord Set included 25’/30 amp  
Start/Stop fuel Shut-off and choke controls Maintenance kit included  
conveniently located on outlet panel  
GP SerieS  
gp series  
GP SErIES: 1800 — 17500 WATTS  
gp 1800 —8000 Watts  
easy to use in a variety of applications, our Gp series of portable  
generators offers affordable reliability. features include:  
Hardened Steel tube cradle for durability  
low-oil Shutdown shuts engine down when oil runs low and prevents  
serious damage  
circuit breaker Protected outlets for circuit protection  
Hour Meter with maintenance resets (excludes Gp1800 and Gp3250)  
gp 15000E — 17500E Watts  
two of the most powerful portable generators on the  
market offer exceptional value:  
16-Gallon fuel tank provides extended run time  
idle control increases fuel efficiency  
• included accessories wheel kit and lifting eye  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
autoMatic tranSfer SwitcHeS  
POWErMASTEr™  
LOAD SHEDDING  
DEvICE  
transfer switches  
AUTOMATIC TrANSfEr SWITCHES  
as a part of the generator system, the transfer switch transfers the electrical load onto the  
generator when power fails. when utility voltage returns, the transfer switch safely returns  
circuit coverage back to the utility.  
create priority loads to ensure  
home comfort during a power  
loss! the powermaster is a load  
shedding device that allows  
a home owner to operate two  
large electrical loads instead  
of only one large appliance.  
examples of this include a  
central air conditioner or an  
electrical hot water heater. when  
the priority load is running,  
the powermaster will lock out  
the other piece of equipment,  
keeping it from turning on until  
the demand is satisfied for the  
priority load. after the demand is  
satisfied, the powermaster allows  
the secondary load to come  
online and operate.  
Distributed Load Center  
Generac offers three models of automatic transfer switches for homeowners who  
choose to back up selected circuits rather than the entire house. pre-wired load  
center models are available with a choice of 8, 10, 12, 14 or 16-circuits.  
Generac makes installation easy and inexpensive.  
all distributed load center models include:  
• 30 ft. pre-wired conduit for connecting the transfer  
switch to the external connection box  
• 2 ft. pre-wired conduit for moving circuits from  
the main panel to the transfer switch  
• Pre-wired external connection box with a weather-proof  
conduit for generator connections  
PowerManager™ Load Shedding Transfer Switch  
the powermanager lts is designed to allow the most efficient use of the generator by  
monitoring and managing the backed up selected and non-selected circuits.  
if the generator approaches overload condition, the non-selected circuits are  
cycled off, allowing the selected circuits to remain powered. this switch is  
designed to operate with the digital controls that are used on single-phase  
air-cooled and liquid-cooled generators from 17 kw through 48 kw.  
• Housed in an aluminum NEMA 3R, outdoor rated enclosure  
for use with units  
• Service entrance rated at 200 Amps with built-in 16 circuit  
priority load center  
up to 60 kW  
• Main contactor protects the selected priority circuits while the  
secondary contactor protects the remaining, non-selected  
circuits located in the existing electrical panel  
• Cover is side hinged for easy access  
RTS Transfer Switches  
rts transfer switches are designed for a wide variety of applications that  
require up to 400 amps. the rts is integrated with the r-series digital  
controller and operates only with standby generators thru 60 kw.  
nema 3r (outdoor rated) enclosures are standard.  
RTS-N (Single and Three-Phase)  
use rts-n models for custom installations or with  
applications that require a sub-panel.  
• 100, 200, or 400 Amp  
RTS-E with Service Disconnect (Single-Phase)  
use rts-e models with service disconnect for quick and  
easy installations.  
• 100, 200, or 400 Amp  
• Service-entrance rated and UL Listed (U.S. only)  
(shown without cover)  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
autoMatic tranSfer SwitcHeS  
THE GENrEADy™ LOAD CENTEr –  
EZ TrANSfEr  
OPErATOr™  
The future in generator installation  
the eZ transfer operator was  
developed by Generac to  
the Genready load center simplifies the generator system  
and installation and maximizes customer savings. in addition,  
advanced engineering creates the easiest and most cost-effective  
installation of any home standby generator on the market. new home  
construction, or renovations requiring electrical upgrades, are the  
opportune time to install a Genready load center and a Generac  
automatic home standby generator.  
install into the Genready load  
center. when installed with  
a generator, it automatically  
transfers the protected circuits  
from utility to generator power  
during a power outage. when  
utility is restored, the eZ  
with a traditional generator installation, three boxes are required:  
the main circuit panel, the automatic transfer switch, and the  
emergency circuit panel.  
transfer operator returns the  
circuits back to utility power.  
the Genready load center replaces the main circuit panel and  
incorporates an automatic transfer switch so all power switching is  
handled within one unit. it becomes a hybrid panel capable of separating out only the  
electrical circuits the homeowner chooses to back up during a power outage.  
Features include:  
• 40 circuit capacity with the use of tandem breakers  
• Dimensions same as a standard 42-circuit main load center  
• Utilizes standard Siemens Load components  
• Compatible with generators rated up to 125 Amps/30 kW  
• Single-Phase applications only  
TM  
Traditional Installation  
Genready™ Installation  
B U I L D E R  
Alliance  
program  
200 Amp  
BUILDErS –  
Join the Generac Builder  
Alliance and get cash back  
for generator purchases  
Automatic  
Transfer  
Switch  
Emergency  
Load  
Center  
Main Load  
Center  
42-Space  
offer your new home customers  
the safety and comfort of  
GenReady Installation Levels  
Basic Advanced Complete  
automatic standby power and  
increase your profits at the same  
time. starting from the first unit  
you buy, Generac will give you  
cash back for your generator  
purchases. in addition to the profit  
earned from each sale, you will  
receive cash rebates for product  
purchased through your indicated  
builder alliance partner(s).  
The innovative GenReady load center combines  
three boxes into one, saving space and money on  
generator installations!  
HTS TrANSfEr SWITCHES  
(Single-Phase and Three-Phase)  
hts transfer switches, designed for simple monitoring,  
operation and maintenance, are constructed to ensure superior  
performance. the hts is part of an integrated system and  
operates only with Generac commercial-series generators  
(70-150 kw) with the h-100 controller. all switch components are  
front adjustable and removable for programming and servicing.  
Program Benefits:  
as a builder, when you join the  
program you will receive:  
• 200 New Home Owner  
brochures  
• Marketing support cd  
recoMMended  
SwitcH  
recoMMended  
SwitcH  
• Factory contact information  
and sales tools  
Model  
Model  
Qt022 ........................rts 100  
Qt025 ........................rts 100  
Qt027 ................ rts 100-200  
Qt030 ................ rts 100-200  
Qt035 ................ rts 100-200  
Qt045 ................ rts 100-200  
Qt060 ................ rts 100-400  
Qt070 ................hts 100-400  
Qt080 ................hts 150-400  
Qt100 ...............hts 200-600  
Qt130 ................hts 200-600  
Qt150 ................hts 300-800  
• Information on installation  
training for your electrical  
contractor  
Visit builder.generac.com to join.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
acceSSorieS  
remote Wireless Monitor for  
Air-Cooled Generators  
add efficiency by allowing for remote  
viewing of generator status and  
parameters from inside the home.  
fascia for Air-Cooled Units  
complement the contoured enclosure with a fascia base wrap  
that snaps together around the bottom of the generator. fits  
air-cooled generators manufactured after april 2008 that have  
the contoured body wrap style. fascia continues the sleek,  
contoured appearance as well as offering  
protection from rodents and insects by  
covering the lifting holes located  
Scheduled  
in the base. available in grey  
only. standard on  
20 kw air-cooled model.  
Maintenance kits  
a scheduled maintenance  
program will ensure that your  
system is always in top operating  
condition and that your warranty  
requirements are met. Generac  
offers a comprehensive line of  
scheduled maintenance kits to ensure long life and top  
performance of your generator system.  
Air-Cooled Generator Transport Cart  
moving a 400 lb generator can be  
hard work. the Generator transport  
cart will assist with moving the  
generator from the truck to the  
planned installation site. allows for  
a single person to easily maneuver  
any air-cooled product to the desired  
installation location.  
Cold Weather kit  
the cold weather kits are  
recommended for areas where the  
temperature drops below 30° f.  
ACCESSOrIES  
Air-Cooled Remote Monitoring Options*  
Model Description  
Air-Cooled Cold Weather Kit  
Model Description  
Contents  
5636  
Remote wireless monitor  
5634  
For air-cooled units mfg prior to 4/08 Battery wrap with internal thermostat  
Liquid-Cooled Remote Monitoring Options  
70 kW and above  
5635  
For air-cooled units mfg after 4/08  
Battery wrap with internal thermostat  
Liquid-Cooled Cold Weather Kit  
Model Description  
Model Description  
Contents  
5464  
5465  
5466  
Remote annunciator panel with 8 relays  
5629  
5630  
5631  
5632  
5633  
For 1.6L engines  
28” Battery warmer w/oil filter  
Remote annunciator panel without LEDs  
and keypad (relays only)  
For 2.4L engines  
28" Battery warmer, zip ties, thermostat  
44" Battery warmer, zip ties, thermostat  
44" Battery warmer, zip ties, thermostat  
44" Battery warmer, zip ties, thermostat & gear oil  
Remote annunciator panel without relays  
For 4.2L engines  
Air-Cooled Scheduled Maintenance Kit  
Model Description  
For 3.0, 4.6, 6.8 direct drive units  
For 6.8L gear drive units  
5661  
5662  
5663  
7 kW, 410 cc kit  
8 kW, 410 cc kit  
10 kW, 530 cc kit  
Liquid-Cooled Extreme Cold Weather Kit  
Model Description  
Use with cold  
weather kit #  
Contents  
12,13, 14,15, 16 kW, 17 & 18 kW,  
760/990 cc kit  
5664  
5665  
18 kW (3600 rpm), 20,  
5615  
Block heater & mounting hardware  
Block heater & mounting hardware  
5629  
25, 30 kW (1.6L)  
20 kW, 999 cc kit  
5616  
5618  
5617  
5619  
5620  
5667  
25 kW (1800 rpm), 45 kW (2.4L)  
5630  
5631  
5632  
5633  
5634  
5635  
Miscellaneous  
Liquid-Cooled Scheduled Maintenance Kit  
Model Description  
35 & 45 kW - both 1800 RPM (4.2L) Block heater & mounting hardware  
Model Description  
60 kW (3.0L)  
Block heater & mounting hardware  
Block heater & mounting hardware  
Block heater & mounting hardware  
Block heater & mounting hardware  
18 kW low speed aluminum, 20, 25 &  
5655  
5651 Base plug for all liquid-cooled models  
5652 Base plug for all air-cooled models mfg prior to 4/08  
5654 Grey paint kit – Units mfg prior to 4/08  
5653 Tan paint kit – Units mfg prior 4/08  
5703 Bisque paint kit – Units mfg after 4/08  
5704 Medium grey paint kit – Units mfg after 4/08  
5685 Air-cooled generator transport cart  
5666 Fascia for air-cooled units mfg after 4/08  
80 kW (4.6L)  
30 kW steel, 3600 RPM units, 1.6L units  
25 kW low speed aluminum & 45 kW  
5656  
70, 100, 130 kW (6.8L)  
150 kW (6.8L)  
steel, 3600 RPM units, 2.4L units  
5657  
5658  
60 kW unit, 3.0L units  
Load Management Options  
Model Description  
35 & 45 kW low speed, aluminum,  
4.2L units  
Contents  
Use with  
5239  
5621  
PowerMaster load shedding device  
Auxiliary transfer switch contact kit  
PowerMaster  
60 kW & below  
R-style switch  
5659  
5660  
80 kW, 4.6L kit units  
Contact, screws & washers  
70, 100, 130, 150 kW, 6.8L units  
* For use with 10-20 kW air-cooled generators manufactured after April 2008.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product SPecificationS  
TrANSfEr SWITCHES  
5499  
GenReady w/ EZ  
Transfer Operator  
RTSS200A3  
Load Shedding  
5447  
EZ Transfer Operator  
5488  
GenReady  
Model  
RTSD100A1  
RTSF100A1  
RTSH100A1  
RTSP100A1  
RTSW100A1  
Amp Rating  
100  
100  
100  
100  
100  
200  
N/A  
200/125  
200/125  
40  
Number of Circuits  
8
10  
12  
14  
16  
16 Priority  
N/A  
40  
1 x 50 Amp, 2 pole  
1 x 40 Amp, 2 pole  
1 x 20 Amp, 2 pole  
4 x 20 Amp, 1 pole  
4 x 15 Amp, 1 pole  
1 x 50 Amp, 2 pole  
1 x 40 Amp, 2 pole  
1 x 20 Amp, 2 pole  
5 x 20 Amp, 1 pole  
5 x 15 Amp, 1 pole  
1 x 50 Amp, 2 pole  
1 x 40 Amp, 2 pole  
1 x 20 Amp, 2 pole  
5 x 20 Amp, 1 pole  
5 x 15 Amp, 1 pole  
1 x 30 Amp, 2 pole  
1 x 20 Amp, 2 pole  
3 x 20 Amp, 1 pole  
3 x 15 Amp, 1 pole  
1 x 40 Amp, 2 pole  
1 x 30 Amp, 2 pole  
3 x 20 Amp, 1 pole  
5 x 15 Amp, 1 pole  
1 x 30 Amp, 2 pole  
1 x 20 Amp, 1 pole  
5 x 15 Amp, 1 pole  
Breakers  
N/A  
N/A  
N/A  
Load Transition Type  
Voltage  
Open  
120/240  
Single  
Open  
120/240  
Single  
Open  
120/240  
Single  
Open  
120/240  
Single  
Open  
120/240  
Single  
Open  
120/240  
Open  
N/A  
N/A  
N/A  
N/A  
3.5  
N/A  
120/240  
Single  
Open  
120/240  
Single  
Phase  
Single  
Enclosure Type  
Dimensions (H” x W” x D”)  
Weight (lbs)  
NEMA 1  
29.5 x 12.1 x 6.8  
62  
NEMA 1  
29.5 x 12.1 x 6.8  
72  
NEMA 1  
29.5 x 12.1 x 6.8  
76  
NEMA 1  
29.5 x 12.1 x 6.8  
78  
NEMA 1  
29.5 x 12.1 x 6.8  
80  
NEMA 1R, 3R  
42.5 x 21 x 8.25  
80  
NEMA 1  
42 x 15 x 4  
45.5  
NEMA 1  
42 x 15 x 4  
49  
Model  
HTSN100A  
HTSN100G  
100  
HTSN100J  
100  
HTSN100K  
100  
HTSN150A  
150  
HTSN150G  
150  
HTSN150K  
HTSN200A  
HTSN200G  
200  
HTSN200J  
200  
HTSN200K  
200  
HTSN300A  
300  
HTSN300G  
300  
HTSN300J  
HTSN300K  
300  
Amp Rating  
Load Transition Type  
Voltage  
100  
Open  
150  
Open  
200  
Open  
300  
Open  
Open  
Open  
120/240  
Three  
Open  
277/480  
Three  
Open  
Open  
120/208  
Three  
Open  
120/208  
Three  
Open  
Open  
Open  
Open  
Open  
120/240  
Single  
120/208  
Three  
120/240  
Single  
277/480  
Three  
120/240  
Single  
120/240  
Three  
277/480  
Three  
120/240  
Single  
120/208  
Three  
120/240  
Three  
277/480  
Three  
Phase  
Enclosure Type  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
Dimensions  
(H” x W” x D”)  
36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 48 x 30 x 12 36 x 24 x 10 36 x 24 x 10 36 x 24 x 10 48 x 30 x 12  
Weight (lbs)  
NEMA 1 / NEMA 3R  
86 / 112  
86 / 112  
86 / 112  
105 / 131  
86 / 112  
89 / 115  
105 / 131  
86 / 112  
89 / 115  
89 / 115  
105 / 131  
101 / 127  
108 / 134  
108 / 134  
124 / 150  
Model  
HTSN400A  
400  
HTSN400G  
HTSN400J  
400  
HTSN400K  
400  
HTSN600A  
HTSN600G  
600  
HTSN600J  
HTSN600K  
HTSN800A  
800  
HTSN800G  
HTSN800K  
800  
Amp Rating  
Load Transition Type  
Voltage  
400  
Open  
600  
Open  
600  
Open  
600  
Open  
800  
Open  
Open  
Open  
Open  
Open  
Open  
Open  
120/240  
Single  
120/208  
Three  
120/240  
Three  
277/480  
Three  
120/240  
Single  
120/208  
Three  
120/240  
Three  
277/480  
Three  
120/240  
Single  
120/208  
Three  
277/480  
Three  
Phase  
Enclosure Type  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 1/3R  
NEMA 12/3R  
NEMA 12/3R  
NEMA 12/3R  
NEMA 12/3R  
NEMA 12/3R  
NEMA 12/3R  
NEMA 12/3R  
Dimensions  
(H” x W” x D”)  
36 x 24 x 10  
101 / 127  
N/A  
36 x 24 x 10  
101 / 127  
N/A  
36 x 24 x 10  
101 / 127  
N/A  
48 x 30 x 12  
124 / 150  
N/A  
60 x 36 x 20  
N/A  
60 x 36 x 20  
N/A  
60 x 36 x 20  
N/A  
60 x 36 x 20  
N/A  
60 x 36 x 20  
N/A  
60 x 36 x 20  
N/A  
60 x 36 x 20  
N/A  
Weight (lbs)  
NEMA 1/ NEMA 3R  
Weight (lbs)  
NEMA 12/NEMA 3R  
650 / 650  
650 / 650  
650 / 650  
650 / 650  
680 / 680  
680 / 680  
680 / 680  
RTSN400G3  
RTSN400J3  
400  
Model  
RTSN100A3 RTSE100A3 RTSN100G3  
RTSN100K3  
RTSN100J3 RTSN200A3 RTSE200A3 RTSN200G3 RTSN200J3  
RTSN200K3  
200  
RTSN400A3  
400  
RTSE400A3  
Amp Rating  
100  
100  
100  
100  
100  
200  
200  
200  
200  
400  
400  
Open w/  
Service  
Open w/  
Service  
Open w/  
Service  
Load Transition Type  
Open  
Open  
Open  
Open  
Open  
Open  
Open  
Open  
Open  
Open  
Open  
Disconnect  
Disconnect  
Disconnect  
Voltage  
120/240  
Single  
120/240  
Single  
120/208  
Three  
277/480  
Three  
120/240  
Three  
120/240  
Single  
120/240  
Single  
120/208  
Three  
120/240  
Three  
277/480  
Three  
120/240  
Single  
120/240  
Single  
120/208  
Three  
120/240  
Three  
Phase  
Enclosure Type  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
NEMA 3R  
Dimensions  
(H” x W” x D”)  
20 x 15.2 x 7.3 20 x 15.2 x 7.3 24 x 20.5 x 7.3 36 x 24.5 x 10.2 24 x 20.5 x 7.3 20 x 15 x 7.3 30 x 16.5 x 7.3 24 x 20.5 x 7.3 24 x 20.5 x 7.3 48 x 30.6 x 13.3 36.1 x 24.4 x 10.2 40 x 31 x 10.5 36.1 x 24.4 x 10.2 36.1 x 24.4 x 10.2  
35 52 49 95 95 35 58 49 49 105 88 134 107 107  
Weight (lbs)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Specifications  
Product Specifications  
air-Cooled  
liquid-Cooled  
Series 3  
QT02224  
22 kW  
22 kW  
91.6  
QT02516  
25 kW  
24 kW  
104.2  
86.8  
QT02724  
27 kW  
25 kW  
112.5  
94  
QT03016  
30 kW  
29 kW  
120.8  
104.2  
N/A  
QT03624  
36 kW  
35 kW  
150  
QT04524*  
45 kW  
45 kW  
187.5  
QT04842*  
48 kW  
45 kW  
200  
QT06024  
60 kW  
60 kW  
250  
QT07068  
70 kW  
68 kW  
291.6  
QT08046  
80 kW  
78 kW  
333.3  
QT10068*  
100 kW  
97 kW  
QT13068  
130 kW  
130 kW  
541.6  
QT15068  
150 kW  
150 kW  
625  
Model  
05526  
8/7 kW  
120/240V  
33.3  
05528  
10/9 kW  
120/240V  
41.6  
05530  
14/13 kW  
120/240V  
58.3  
05531  
17/16 kW  
120/240V  
70.8  
05532  
17/16 kW  
120/240V  
70.8  
05533  
20/18 kW  
120/240V  
83.3  
Rated Power (LPG/NG)  
Voltage (Single-Phase)  
Amps @ 240V LPG  
Amps @ 240V NG  
Engine/Alternator RPM  
Engine  
Rated Power LP  
Rated Power NG  
Amps @ 240V, 1 Ø LP  
Amps @ 208V, 3 Ø LP  
Amps @ 240V, 3 Ø LP1  
Amps @ 480V, 3 Ø LP  
Engine/Alternator RPM  
Engine Size  
416.6  
29.2  
37.5  
54.2  
66.6  
66.6  
75  
76  
125  
156.3  
167  
208.4  
180.6  
90.3  
243.1  
277.9  
347.3  
451.5  
521  
3600/3600  
OHVI / 410cc  
62 (1.68)  
140  
3600/3600  
OHVI / 530cc  
70 (1.93)  
156  
3600/3600  
OHVI / 992cc  
84 (2.30)  
220  
3600/3600  
OHVI / 992cc  
94 (2.57)  
261  
3600/3600  
OHVI / 992cc  
94 (2.57)  
262  
3600/3600  
OHVI / 999cc  
106 (2.90)  
294  
N/A  
N/A  
N/A  
108  
135.4  
144  
210.7  
240.8  
301  
391.3  
451.5  
N/A  
N/A  
N/A  
N/A  
54  
67.7  
72  
105.3  
120.4  
150.5  
195.6  
225.7  
Fuel Consumption LPG  
Fuel Consumption NG  
Quiet-Test Low Speed Exercise  
db(A) at Exercise  
1800/1800  
2.4L  
3600/3600  
1.6L  
1800/1800  
2.4L  
3600/3600  
1.6L  
1800/1800  
2.4L  
3600/3600  
2.4L  
1800/1800  
4.2L  
3600/3600  
2.4L  
1800/1800  
6.8L  
3600/3600  
4.6L  
2300/1800  
6.8L  
3000/1800  
6.8L  
3600/3600  
6.8L  
No  
No  
No  
Yes  
Yes  
Yes  
Cylinder Arrangement  
Fuel Consumption LPG  
Fuel Consumption NG  
Quiet-Test Low Speed Mode  
db(A) at Exercise  
In-line 4  
120 (3.3)  
316  
In-line 4  
175 (4.81)  
437  
In-line 4  
149 (4.1)  
359  
In-line 4  
209 (5.7)  
525  
In-line 4  
199 (5.4)  
480  
In-line 4  
286 (7.86)  
720  
V-6  
In-line 4  
332 (9.0)  
862  
V-10  
V-8  
V-10  
V-10  
V-10  
62  
63  
66  
60  
60  
60  
261 (7.2)  
661  
411 (11.3)  
1020  
465 (12.78)  
1154  
507 (13.9)  
1260  
719.8 (19.56)  
1786  
830.6 (22.6)  
2061  
db(A) at Normal Operating Load  
Enclosure  
62  
63  
66  
66  
66  
66  
Steel  
Steel  
Steel  
Steel  
Aluminum  
Gray  
Aluminum  
Gray  
Enclosure Color  
Bisque  
Bisque  
Bisque  
Bisque  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Dimensions (L” x W” x H”)  
Generator Weight (lbs.)  
48 x 24 x 28.25 48 x 24 x 28.25 48 x 24 x 28.25 48 x 24 x 28.25 48 x 24 x 28.25 48 x 24 x 28.25  
336 375 425.5 445 414 451  
61  
62  
61  
62  
58  
61  
60  
63  
61  
64  
61  
65  
66  
db(A) at Normal Operating Load  
Transfer Switch Type Needed  
Enclosure Material  
70  
74  
70  
75  
64  
73  
65  
71  
65  
74  
72  
75  
79  
RTS  
RTS  
RTS  
RTS  
RTS  
RTS  
RTS  
RTS  
HTS  
HTS  
HTS  
HTS  
HTS  
Aluminum  
Gray  
Steel  
Aluminum  
Gray  
Steel  
Aluminum  
Bisque  
77 x 33.5 x 45  
N/A  
Steel  
Aluminum  
Gray  
Steel  
Steel or Alum  
Tan  
Steel or Alum  
Tan  
Steel or Alum  
Tan  
Steel or Alum  
Tan  
Steel or Alum  
Tan  
Enclosure Color  
Bisque  
62.2 x 29 x 33.5  
875  
Bisque  
62.2 x 29 x 33.5  
935  
Bisque  
77 x 33.5 x 45  
1414/14642  
Tan  
Dimensions (L” x W” x H”)  
Generator Weight Steel (lbs.)  
62.2 x 29 x 33.5  
N/A  
62.2 x 29 x 33.5  
N/A  
77 x 33.5 x 45  
N/A  
89 x 34 x 48  
1650  
96.5 x 37 x 48  
2185  
116 x 37 x 55**  
2010  
116 x 37 x 55**  
2705/27552  
116 x 37 x 55**  
2873  
116 x 37 x 55**  
2666  
Generator Weight Aluminum (lbs.)  
843  
N/A  
891  
N/A  
1683  
N/A  
1740/17902  
1650  
2040  
1836  
2531/25812  
2699  
2492  
* California emission compliant model. Must specify with  
“Y” at end of typecode when ordered.  
1 Consult factory for availability  
2 California emission compliant model weight  
** Height does not include measurement of exhaust stack(s).  
*** All specifications subject to change without notice.  
3 See product selection guide to customize your generator  
portable  
GP15000E  
GP17500E  
XP4000  
XP8000E  
5606/5712*  
8000 Watts  
12000 Watts  
Generac 410cc OHVI  
Yes  
XP10000E  
Series  
GP1800  
5723  
GP3250  
5724  
GP5500  
5736/5737*  
5500 Watts  
6875 Watts  
389cc OHV  
No  
GP6500  
GP7000  
GP7000E  
5626  
GP8000  
GP8000E  
5681  
GP10000E  
5739  
Model #  
5623/5700*  
6500 Watts  
8000 Watts  
389cc OHV  
No  
5625  
7000 Watts  
8750 Watts  
Generac 410cc OHVI  
Yes  
5680  
8000 Watts  
10000 Watts  
Generac 410cc OHVI  
Yes  
5734  
15000 Watts  
22500 Watts  
Generac 992cc OHVI  
Yes  
5735  
5604/5713*  
4000 Watts  
5000 Watts  
Generac 220cc OHVI  
Yes  
5607  
10000 Watts  
15000 Watts  
Generac 530cc OHVI  
Yes  
Running Watts  
Starting Watts  
Engine Size and Type  
Pressure Lube w/Filter  
Starting Method  
Battery Included  
Covered Outlets  
1800 Watts  
2050 Watts  
163cc OHV  
No  
3250 Watts  
3750 Watts  
206cc OHV  
No  
7000 Watts  
8750 Watts  
Generac 410cc OHVI  
Yes  
8000 Watts  
10000 Watts  
Generac 410cc OHVI  
Yes  
10000 Watts  
15000 Watts  
Generac 530cc OHVI  
Yes  
17500 Watts  
26250 Watts  
Generac 992cc OHVI  
Yes  
Electric  
Yes  
Recoil  
Recoil  
Recoil  
Recoil  
Recoil  
Electric/Recoil  
Yes  
Recoil  
Electric/Recoil  
Yes  
Electric  
Electric  
Recoil  
Electric/Recoil  
Yes  
Electric  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
Yes  
Yes  
N/A  
Yes  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
No  
2x5-20R  
GFCI 2x5-20R  
2xL5-30R  
1xL14-30R  
1x14-50R  
2x5-20R  
GFCI 2x5-20R  
2xL5-30R  
1xL14-30R  
1x14-50R  
GFCI 4x5-20R  
1xL5-30R  
1XL14-30R  
1X14-50R  
GFCI 4x5-20R  
1xL5-30R  
1x14-50R  
4x5-20R  
1xL14-30R  
4x5-20R  
1xL14-30R  
4x5-20R  
1xL14-30R  
4x5-20R  
1xL14-30R  
4x5-20R  
1xL14-30R  
4x5-20R  
1xL14-30R  
GFCI 4x5-20R  
1xL14-20R  
GFCI 4x5-20R  
1xL14-30R  
2x5-20R  
4x5-20R  
Outlets  
1x10A 12Vdc  
1x10A 12Vdc  
Hour Meter w/ Maintenance Resets  
Low-Oil Shutdown  
Fuel Tank Type and Size  
Run Time at 50%  
No  
Low Level  
Steel, 4.0 Gal  
14 Hours  
No  
No  
Low Level  
Steel, 4.0 Gal  
13.5 Hours  
No  
Yes  
Low Level  
Steel, 6.6 Gal  
10 Hours  
No  
Yes  
Low Level  
Steel, 6.6 Gal  
9 Hours  
Yes  
Low Pressure  
Steel, 8.0 Gal  
11 Hours  
No  
Yes  
Low Pressure  
Steel, 8.0 Gal  
11 Hours  
No  
Yes  
Low Pressure  
Steel, 8.0 Gal  
8 Hours  
Yes  
Low Pressure  
Steel, 8.0 Gal  
8 Hours  
Yes  
Low Pressure  
Steel, 10.0 Gal  
10 Hours  
No  
Yes  
Low Pressure  
Resin, 16.0 Gal  
10 Hours  
No  
Yes  
Low Pressure  
Resin, 16.0 Gal  
10 Hours  
No  
Yes  
Low Pressure  
Steel, 5.0 Gal  
12 Hours  
20' 20A  
Yes  
Low Pressure  
Steel, 8.0 Gal  
8 Hours  
Yes  
Low Pressure  
Steel, 10.0 Gal  
10 Hours  
No  
Cord Set Included  
No  
No  
No  
20’ 30A  
Handles  
N/A  
Folding  
Fold Down/Locking  
Yes  
Fold Down/Locking  
Yes  
Fold Down/Locking  
Yes  
Fold Down/Locking  
Yes  
Fold Down/Locking  
Yes  
Fold Down/Locking  
Yes  
Fold Down/Locking  
Yes  
Fixed, D-Style  
Yes  
Fixed, D-Style  
Yes  
Fold Down/Locking  
Yes  
Fold Down/Locking  
Yes  
Fold Down/Locking  
Yes  
First Oil Included  
Yes  
Yes  
Maintenance Kit Included  
Emission Certified  
CSA Certified Model Availability  
Warranty  
No  
No  
No  
50 States1  
No  
50 States1  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
50 States2  
Yes  
50 States1  
Yes  
49 States  
1st Quarter 2009  
2 Year Limited  
49 States  
1st Quarter 2009  
2 Year Limited  
49 States  
Yes  
49 States  
No  
49 States  
No  
49 States  
Yes  
49 States  
No  
50 States  
No  
50 States  
No  
49 States  
Yes  
Yes  
Yes  
Yes  
Yes  
2 Year Limited  
2 Year Limited  
2 Year Limited  
2 Year Limited  
2 Year Limited  
2 Year Limited  
2 Year Limited  
2 Year Limited  
2 Year Limited  
3 Year Limited  
3 Year Limited  
3 Year Limited  
33.5 x 26.5  
x 27.5  
33.5 x 26.5  
x 27.5  
Dimensions (L” x W” x H”)  
23.5 x 17 x 17.5  
25.5 x 21 x 19  
33.5 x 26.5 x 27.5  
33.5 x 26.5 x 27.5  
33.5 x 26.5 x 27.5  
33.5 x 26.5 x 27.5  
33.5 x 22 x 27.5  
48.5 x 30.75 x 38.5  
48.5 x 30.75 x 38.5  
29.25 x 23.5 x 26  
32.5 x 26 x 29  
35 x 28 x 36  
Product Weight (lbs.)  
Availability  
90.5  
101.5  
180  
185  
190  
195  
200  
205  
300  
373  
400  
195  
255  
300  
4th Quarter 2008  
4th Quarter 2008  
4th Quarter 2008  
Available Now  
Available Now  
Available Now  
Available Now  
Available Now  
2nd Quarter 2009  
1st Quarter 2009  
1st Quarter 2009  
1st Quarter 2009  
Available Now  
1st Quarter 2009  
* California Emission Model  
All portable specifications and models subject to change. Please consult factory for availability.  
1 California models available 4th Quarter 2008 2 California models available 1st Quarter 2009  
12  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Generac - life iS better witH Power.  
Product Selection Guide  
LIQUID-COOLED GENErATOrS  
to build a generator and transfer switch, specify each ordering option below.  
Generator voltage ratings must match transfer switch voltage.  
STEP 1  
STEP 2  
STEP 3  
STEP 4  
STEP 5  
STEP 6  
kW Ratings  
e.g. (45 kW = 045)  
Engine  
e.g. (5.4L = 54)  
Voltage  
Fuel  
Enclosure  
Steel = S  
Aluminum = A  
Emission/  
Catalytic  
Converter  
120/240 1ø = A  
120/208 3ø = G  
120/240 3ø = J  
277/480 3ø = K  
Natural Gas = n  
Propane Vapor = V  
Field Convertable  
to LP = *  
No Catalyst = n  
1Catalyst & A/F  
Ratio = Y  
22  
25  
27  
30  
36  
45  
48  
60  
60  
70  
80  
100  
130  
150  
2.4L @ 1800 RPM  
1.6L @ 3600 RPM  
2.4L @ 1800 RPM  
1.6L @ 3600 RPM  
2.4L @ 1800 RPM  
2.4L @ 3600 RPM  
4.2L @ 1800 RPM  
2.4L @ 3600 RPM  
2.4L @ 3600 RPM  
A,G,J  
A,G,J  
A,G,J  
A,G,J  
n*  
n*  
n*  
n*  
n*  
n*  
n*  
n
V
n, V  
n, V  
n, V  
n, V  
n, V  
A
S
A
S
A
S
A
S
S
S, A  
S, A  
S, A  
S, A  
S, A  
n/A  
n/A  
n/A  
n/A  
n/A  
n, Y  
n, Y  
n
n
n
n
n, Y  
n, Y  
n, Y  
ALL  
MODELS  
bEGin  
A, G, J, K  
A, G, J, K  
A, G, J, K  
A, G, J, K  
A, G, J, K  
A, G, J, K  
A, G, J, K  
A, G, J, K  
A, G, J, K  
A, G, J, K  
WiTH QT  
6.8L @ 3600 RPM  
4.6L @ 3600 RPM  
6.8L @ 2300 RPM Gear Drive  
6.8L @ 3000 RPM Gear Drive  
6.8L @ 3600 RPM  
SAMPLE  
Q T  
0 6 0  
2 4  
K
N
S
N
Q T  
MODEL nuMbER (Enter on Order Form)  
1 = Catalyst & A/F Ratio may not be available for all models. Contact Your Generac representative for more information.  
TrANSfEr SWITCHES  
STEP 1  
Selection Criteria Transfer Switch  
STEP 2  
STEP 3  
Amp Rating  
e.g. (200 Amp = 200) 120/240 1ø = A  
120/208 3ø = G  
STEP 4  
Voltage  
STEP 5  
Switch Type  
Normal = n  
Enclosure Type3,4  
NEMA 1 = 1  
R Controller = RTS  
H-100 Controller = HTS Service Entrance Rated1 = E  
NEMA 3R = 3  
NEMA 12 = 4  
Load Shedding2 = S  
8 cct. Integrated Load Center2 = D  
10 cct. Integrated Load Center2 = F  
12 cct. Integrated Load Center2 = H  
14 cct. Integrated Load Center2 = P  
16 cct. Integrated Load Center2 = W  
16 cct. Priority Load Center,  
120/240 3ø = J  
277/480 3ø = K  
Load Shedding3 = S  
For Standby  
Generators  
8 - 60 kW  
RTS  
n, E, D, F, H, P, W, S  
100, 200, 400  
A, G, J, K  
1, 3  
For Standby  
Generators  
70 - 150 kW  
HTS  
n
100, 150, 200,  
400, 600, 800  
A, G, J, K  
1, 3, 4  
2 0 0  
G
3
R T S  
N
SAMPLE  
PRODuCT nuMbER  
(Enter on Order Form)  
1 = 120/240 1ø, NEMA 3R Only  
2 = 200 Amp service entrance rated NEMA 3R  
3 = HTS 100 - 400 Amp NEMA 1/3R Only  
4 = HTS 600 - 800 Amp NEMA 12/3R Only  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Generac - life iS better witH Power.  
Generac – a Powerful History  
A TrADITION Of QUALITy AND INNOvATION  
for almost 50 years, Generac power systems has led the industry with  
innovative design and superior manufacturing. when it comes to  
developing products that are both durable and reliable, we stand head and  
shoulders above our competition. thats because our sole focus has been,  
and continues to be, standby power. the result of our efforts can be seen in  
every inch of our product offerings.  
our vertical integration allows us to control the quality, availability and  
flow of materials throughout the manufacturing process. we design and  
build our own air-cooled engines, alternators, control systems, automatic  
transfer switches, enclosures and base tanks (for diesel and bi-fuel™  
models). our products are fully integrated as complete power systems and  
each genset is factory tested prior to shipment.  
because of our ongoing commitment to quality and innovation, Generac is  
the name that home and business owners have  
come to trust.  
COMMITMENT TO SErvICE  
Generac is committed to providing our customers with unsurpassed after-  
the-sale service support. our nationwide dealer network has factory trained  
technicians on staff and maintains large inventories of Generac parts,  
components and accessories.  
our state-of-the-art training center ensures that Generac service  
technicians are always up to date on new product innovations and  
improvements. technicians receive comprehensive technical training and  
extensive hands-on experience in the installation, repair and maintenance  
of Generac products.  
Generacs commitment to service includes scheduled maintenance  
programs, warranty assistance and emergency service to ensure that  
Generac customers are never left in the dark.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Generac power systems, inc.  
highway 59 & hillside rd.  
p.o. box 8  
waukesha, wi 53187  
1-888-Generac  
MyGenerac.com  
©2008 Generac power systems, inc. all rights reserved.  
specifications are subject to change without notice.  
bulletin 0170030sby / printed in usa 04.04, rev. 11.08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Escali Scale Plena User Manual
Euro Pro Vacuum Cleaner NV70 User Manual
Fisher Price Bicycle 72639 User Manual
Fisher Price Crib Toy N1128N1128 User Manual
GE Cordless Telephone 16197920 User Manual
GE Griddle 168999 User Manual
GE Washer Dryer WBXR1090 User Manual
GE Washer Dryer WCXH208 WCXH214 WSXH208 WPXH214 User Manual
Gianni Industries Door PBT 015 User Manual
Giant Water Pump GP7145GB User Manual