Furuno SONAR FSV 30 User Manual

Installation ManuaBlack  
COLOR SCANNING SONAR  
FSV-30/FSV-30S  
SAFETY INSTRUCTIONS................................................................................................i  
SYSTEM CONFIGURATION..........................................................................................iii  
EQUIPMENT LISTS.......................................................................................................iv  
1. MOUNTING THE EQUIPMENT................................................................................1-1  
1.1 Hull Unit ................................................................................................................................1-1  
1.2 Processor Unit ......................................................................................................................1-8  
1.3 Control Unit...........................................................................................................................1-9  
1.4 Transceiver Unit..................................................................................................................1-12  
1.5 Grounding the Equipment...................................................................................................1-12  
1.6 Installing the Attachment Flange (option)............................................................................1-13  
1.7 Cable Extension Kit (option) ...............................................................................................1-14  
1.8 Installing the Attachment Kit (option)...................................................................................1-15  
2. WIRING ....................................................................................................................2-1  
2.1 How to Use the Crimping Tool, Pin Extractor........................................................................2-1  
2.2 Wiring....................................................................................................................................2-2  
2.3 Processor Unit .................................................................................................................... 2-4  
2.4 Transceiver Unit..................................................................................................................2-10  
2.5 Cable Extension Kit ............................................................................................................2-14  
2.6 Input Voltage and Fuses .....................................................................................................2-18  
3. ADJUSTMENT AND CHECK...................................................................................3-1  
3.1 Hull Unit Check.....................................................................................................................3-1  
3.2 Heading Adjustment..............................................................................................................3-5  
3.3 Configuring Own Ship Mark..................................................................................................3-7  
3.4 Other SYSTEM Menu Items .................................................................................................3-9  
3.5 CONE Board Setting in the Processor Unit.........................................................................3-13  
3.6 DIP Switch Setting ............................................................................................................3-14  
4. CONNECTING THE EXTERNAL INTERFACE CS-120A ........................................4-1  
PACKING LISTS.........................................................................................................A-1  
OUTLINE DRAWINGS................................................................................................ D-1  
INTERCONNECTION DIAGRAMS ............................................................................. S-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INSTRUCTIONS  
WARNING  
DANGER  
Install the specified transducer tank  
in accordance with the installation  
instructions. If a different tank is to be  
installed the shipyard is solely respon-  
sible for its installation, and it should  
be installed so the hull will not be  
damaged if the tank strikes an object.  
Keep away from moving  
shaft of the hull unit.  
Gears may cause injury.  
The tank or hull may be damaged if the  
tank strikes an object.  
WARNING  
Do not open the cover  
unless totally familiar with  
electrical circuits and  
service manual.  
If a steel tank is installed on a wooden  
or FRP vessel, take appropriate  
measures to prevent electrolytic  
corrosion.  
Electrolytic corrosion can damage the  
hull.  
High voltage exists inside the  
equipment, and a residual  
charge remains in capacitors  
several minutes after the  
power is turned off. Improper  
handling can result in electri-  
cal shock.  
Be sure that the power supply is  
compatible with the voltage rating of  
the equipment.  
Connection of an incorrect power supply  
can cause fire or damage the equipment.  
Turn off the power at the switchboard  
before beginning the installation.  
Fire or electrical shock can result if the  
power is left on.  
CAUTION  
Ground the equipment to  
prevent electrical shock and  
mutual interference.  
Do not install the equipment where it  
may get wet from rain or water splash.  
Water can cause fire or electrical shock, or  
damage the equipment.  
Be sure no water leaks in at the trans-  
ducer installation site.  
Water leakage can sink the vessel. Also  
confirm that the transducer will not loosen  
by ship's vibration. The installer of the  
equipment is solely responsible for the  
proper installation of the equipment.  
FURUNO will assume no responsibility for  
any damage associated with improper  
installation.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
Maximum speed while the transducer is  
projected or being raised or lowered  
is as below, to prevent damage to the  
transducer.  
Projected Raising/  
Lowering  
1200 mm stroke Max. 18 kt Max. 15 kt  
1600 mm stroke Max. 15 kt Max. 12 kt  
Observe the following compass safe  
distances to prevent interference to a  
magnetic compass:  
Standard  
compass  
Steering  
compass  
Processor Unit  
Control Unit  
1.55 m  
0.20 m  
1.05 m  
0.15 m  
Other equipment should be positioned at  
least 7 m away from a magnetic compass.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM CONFIGURATION  
VGA Monitor  
CONTROL UNIT  
FSV-3001  
AD Converter  
AD-10  
Gyrocompass  
Loudspeaker  
Sub Monitor  
Current  
Indicator  
Current  
Indicator/Log  
Echo Sounder,  
Current Indicator,  
other  
E/S Interface  
VI-1100A  
PROCESSOR UNIT  
FSV-3002/3002S  
Navigator 1  
Navigator 2  
Net Recorder  
VI-1100A  
VI-1100A  
External  
Interface CS-120A  
(Note 1)  
Net Sonde  
Junction Box  
CS-170  
Net Sonde  
220 VAC,  
3φ, 50/60 Hz  
Cable for  
100/110/115/  
220/230 VAC,  
1φ, 50/60 Hz  
Extension Kit  
FSV-305-5 or  
FSV-305-15  
(incl. Junction  
Box)  
HULL UNIT  
Hull unit  
Specifications  
FSV-303  
TRANSCEIVER  
1200 mm stroke  
FSV-303-R  
UNIT  
FSV-304  
FSV-304-R  
FSV-301  
1600 mm stroke  
100/110/115/  
220/230 VAC,  
1φ, 50/60 Hz  
Standard  
Local Supply  
Option  
Note 1: Power Kit FSV-2403 (option, installed in  
processor unit) required to connect CS-120A.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EQUIPMENT LISTS  
Standard supply  
Name  
Control Unit  
Type  
FSV-3001  
Code No.  
Qty  
Remarks  
1
With cable  
FSV-3002  
For FSV-30  
Processor Unit  
Transceiver Unit  
Hull Unit  
1
1
1
FSV-3002S  
FSV-301  
For FSV-30S  
FSV-303/303-R  
FSV-304/304-R  
1200 mm stroke  
1600 mm stroke  
Signal cable 10S2078  
CP10-06000  
CP10-06201  
CP10-06100  
000-144-389 1 set (between transceiver unit and  
hull unit, 8 m)  
For transceiver unit. See  
packing list.  
Installation Materials  
007-008-540 1 set  
1 set For processor unit  
000-067-067  
CP10-04502, CP10-04506.  
See packing list.  
For transceiver unit. See  
packing list.  
SP10-03101  
SP10-02601  
007-008-530 1 set  
006-921-340 1 set  
Spare Parts  
Accessories  
For processor unit. See  
packing list.  
SP10-02603  
FP10-02901  
FP10-02201  
006-921-360 1 set For processor unit  
007-008-780 1 set For processor unit  
006-922-390 1 set For control unit  
Optional Equipment  
Name  
Control Unit  
37-core Cable  
E/S Interface  
Type  
Code No.  
Qty  
1
Remarks  
Specify length  
FSV-3001  
10S1258  
VI-1100A  
CS-170  
001-113-000-10  
1
1
Net Sonde  
1
Junction Box  
Power Supply Kit  
NMEA Cable  
FSV-2403  
000-067-013  
000-154-037-10  
000-154-053-10  
000-555-043  
1
1
1
1
For connection of CS-120A  
10 m, NMEA, 6P-6P  
MJ-A6SPF0012-100C  
MJ-A6SPF0012-050C  
VVS 0.3×8C *6M*  
5 m, NMEA, 6P-6P  
8-core Cable  
6 m, for echosounder, 02S8040  
Attachment  
Flange  
OP10-27  
000-067-050  
1
Attachment Kit  
Loudspeaker  
OP10-24  
SEM-21Q  
006-943-530  
000-144-917  
1
1
Installation  
Materials  
See back of manual for details.  
CP10-04801  
006-934-240  
Cable Extension  
Kit  
FSV-305-5  
000-067-072  
000-067-073  
Junction box, 10S2240, 10S2144  
Junction box, 10S2240, 10S2145  
1
1
FSV-305-15  
Data Recording  
Kit  
OP10-31  
000-017-095  
Calibration Ball  
OP10-33  
OP10-34  
000-017-096  
000-017-097  
1
1
φ38.1  
φ47.625  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. MOUNTING THE EQUIPMENT  
NOTICE  
Do not apply paint, anti-corrosive sealant  
or contact spray to coating or plastic  
parts of the equipment.  
Those items contain organic solvents that  
can damage coating and plastic parts,  
especially plastic connectors.  
1.1 Hull Unit  
Note 1: The raise/lower control box on the hull unit contains a motion sensor. Therefore,  
never drop the hull unit.  
Note 2: Handle the transducer carefully. Shock will damage its sensitive components.  
1.1.1 Mounting considerations  
Decide the location of the hull unit through consultation with the dockyard and ship owner.  
When deciding the location, the following points should be taken into account.  
Choose an area where propeller noise, cruising noise, air bubbles and interference from  
turbulence are at a minimum. Generally, the point at 1/3 to 1/2 of the ship’s length from  
the bow on or near the keel is optimum. On-the-keel installation is advantageous for  
minimizing oil consumption in comparison with off-the-keel. If the hull unit can not be  
installed on the keel, the center of the retraction tank should be within 600 mm of the keel  
to prevent a rolling effect. For large ship with deep draft, the hull unit can be installed at  
the bow.  
1/3  
1/2  
Within 600 meter  
Hull unit mounting location  
Choose a place where the hull bottom is flat and the draft is sufficiently deep. Normally,  
the transducer should protrude at least 500 mm beyond the keel to minimize the effect of  
air foam and bubbles.  
Choose a place where interference from other transducers is minimal. The hull unit  
should be at least 2.5 m away from the transducers of other equipment.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
No obstacle should be in the fore direction since it causes a shadow zone and aerated  
water, resulting in poor sonar performance.  
The physical distance between the hull unit and the transceiver unit should be no more  
than 5 m.  
The space shown in the figure on the next page is required around the hull unit for wiring  
and maintenance.  
If the ambient temperature around the unit will be below 0°C, provide the sonar  
compartment with a heater to keep the temperature above 0°C.  
1300  
650  
Maintenance space, example sonar compartment  
Note: After mounting the equipment, install anti-vibration stays, referring to page 1-7.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.2 Shortening the retraction tank  
The retraction tank is 1300 mm in length when supplied. Shorten the tank as necessary so  
that the transducer positions well below the keel when it is fully lowered. The following table  
provides guidelines for shortening the tank. Refer also to the retraction tank installation  
drawing at the back of this manual.  
Installation  
Method  
D
Same as left.  
Same as left.  
D
XDCR Travel  
Remove 280  
- 290 mm  
from the  
Remove 280 - 290 mm  
from the bottom.  
Note that the length  
"D" must be less than  
1170 mm.  
Same as left.  
1200 mm  
stroke  
bottom.  
Remove less than  
290 mm from the  
bottom. Note that the  
length "D" must be less  
than 1570 mm.  
Remove  
less than  
290 mm  
from the  
bottom.  
Same as left.  
1600 mm  
stroke  
Guidelines for shortening the retraction tank  
Note 1: For the 1200 mm stroke hull unit, the transducer will not fully protrude unless the  
tank is shortened by at least 280 mm from the bottom, and cannot be fully retracted  
if more than 290 mm is removed.  
Note 2: For the 1600 mm stroke hull unit, the transducer cannot be fully retracted if the tank  
is removed more than 290 mm.  
Note 3: When 290 mm is removed and “D” is minimum, the effect of air foam is minimized  
because the transducer fully protrudes in water.  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.3 Remarks for installation of retraction tank  
1. Make, if possible, the installation location a double bottom structure.  
2. Install, if possible, the tank on the keel where the tank can be most firmly fixed.  
3. Install the reinforcement ribs as near as possible to the top of the retraction tank,  
allowing space for tightening of nuts and bolts.  
Retraction tank  
Reinforcement rib  
250-300 mm  
How to install reinforcement ribs  
4. Add a doubling plate (a plate added to another to give extra strength or stiffness) at the  
location where the retraction tank is welded to the hull bottom. The size of the doubling  
plate is normally 1300 mm in diameter so that it may lie across two bottom frames.  
5. Use a chisel to inscribe the bow mark on the attachment flange.  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.4 Installing hull unit on retraction tank  
After welding the retraction tank and allowing sufficient time for cooling, install the hull unit  
as follows:  
1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount  
of grease. Place the O-ring in position on the tank flange.  
2. Orient the hull unit so that the bow mark (inscribed) on its flange points toward the ship’s  
bow. Note that heading adjustment is required if the bow mark is not facing the ship’s  
bow.  
3. Confirm that the O-ring is in position. Place the hull unit on the tank.  
4. Coat every washer, nut and bolt with a slight amount of grease to ease removal. Fasten  
the hull unit to the retraction tank with flat washers, spring washers and hex bolts.  
5. Reinforce the hull unit against vibration by extending stays to the ship’s hull from the two  
eye bolts at the top of the hull unit, referring to the procedure on page 1-7.  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hex. Nut  
Spring Washer  
Flat Washer  
Bow Mark  
Hull Unit Flange  
O-ring  
Tank Flange  
Flat Washer  
Hex. Bolt  
Hex. Nut  
Spring Washer  
O-ring  
Flat Washer  
O-ring  
Retraction Tank  
Flat Washer  
Hex. Bolt  
Hex. Nut  
Spring Washer  
Stern side (seven locations)  
Bow side (17 locations)  
Installation of hull unit  
1-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.5 Installing stays (anti-vibration measure)  
Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron  
with a size of 75×75×9 mm or more and at least two pieces should be used; one each to  
ship’s bow and stern directions. Install if possible, two more stays in ship’s transverse  
direction. This measure must be done to prevent damage to the transducer.  
Bow  
Stay  
Stay  
Hull Unit  
Proper installation of stays  
Do not install the stays on a crossbeam on an overhead. Vibration-resistance effect is  
reduced since vibration is applied to the stays as rotation force. Install them horizontally.  
Crossbeam  
on overhead  
(WRONG installation method)  
Stay  
Eye Bolt  
PROPER installation  
Hull Unit  
90  
Proper and improper stay installation methods  
1-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2 Processor Unit  
Mounting considerations  
When choosing a mounting location, keep in mind the following points:  
The processor unit must be mounted upright.  
Locate the unit out of direct sunlight and away from heat sources because of heat that  
can build up inside the cabinet.  
Do not locate the equipment where it may be subjected to water splash or rain.  
Be sure the mounting location is strong enough to support the weight of the unit under the  
continued vibration which is normally experienced on the ship. If necessary reinforce the  
mounting location.  
Determine the mounting location considering the length of the cables below.  
Signal cable from the transceiver unit  
Control cable from the control unit (when locally supplied monitor is used)  
Leave sufficient space on the sides and rear of the unit to facilitate maintenance. Also,  
leave a foot or so of "service loop" in cables behind the unit so it can be pulled forward for  
servicing or easy removal of connectors.  
Make free space of 400 mm between the processor unit and bulkhead to prevent cable  
stress.  
Observe the compass safe distances shown on page ii to prevent interference to a  
magnetic compass.  
Cable fixing hole  
Processor unit, rear view  
1-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting procedure  
1. Unfasten two bolts from the bottom of the front side of the processor unit. Pull the unit  
toward you to separate it from the mounting base.  
2. Use six bolts (M6×20, supplied as installation material) to fix the mounting base.  
3. Place the processor unit in front of the mounting base.  
4. Push the unit forward until it touches the end of the mounting base.  
5. Refasten two bolts removed at step 1 to fix the unit to the mounting base.  
504  
477  
5.5  
34  
8
200+1  
195+1  
Front view  
Top view  
Processor unit  
1.3 Control Unit  
The control unit may be mounted on a tabletop with or without the KB (keyboard) fixing  
plate (supplied), which mounts the control unit at an angle. If the control unit is not to be  
fixed permanently, lay it atop the rubber feet (supplied as accessories). Be sure to observe  
the compass safe distances noted on page ii to prevent interference to a magnetic  
compass.  
(1) Rubber feet  
Attach four rubber feet to the bottom of the control unit if it is not going to be permanently  
fixed.  
1-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(2) Mounting without KB fixing plate  
1. Drill four mounting holes of 6 mm diameter to fasten the control unit, referring to the  
outline drawing at the back of this manual.  
2. Referring to the outline drawing for the control unit at the back of this manual, make a  
cutout in the mounting location large enough to accommodate the name plate so the  
control unit will lie flat.  
3. Fix the control unit with four bolts (M5) from under the tabletop. (M5 bolts with a  
sufficient length for the thickness of the tabletop should be provided locally.)  
467±1  
Fixing hole  
φ6  
FSV-30  
Control unit  
(3) Mounting with KB fixing plate  
1. To fix the control unit to a desired location at an angle, fasten the KB fixing plate to the  
control unit and desired location with two upset screws (M5×10, supplied) and two  
tapping screws (φ6.5, local supply) as below.  
Upset screw (M5x10)  
FSV-30  
Tapping screw  
( 6.5)  
KB fixing plate  
How to attach KB fixing plate  
2. Set dust cover (supplied) to the control unit.  
1-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Passing the cable through the bottom of the control unit (for permanent mounting)  
For permanent mounting methods (2) and (3), the control cable can be passed through the  
bottom of the control unit as follows:  
1. Unfasten eight screws (M4) to remove the cover from the bottom of the control unit.  
2. Unscrew two screws (M4×10) to remove the cable clamp.  
3. Disconnect two connectors J1 and J2 from the circuit board.  
4. Attach the control cable to the control unit cover with the cable clamp (removed at step  
2), two flat head screws (M4), flat washers, spring washers and nuts (hardware:  
supplied).  
Screw  
M4x8 (8 pcs.)  
Previous cable hole  
Nut  
Clamp  
Spring washer  
Flat washer  
Screw (M4x12)  
Fasten the cable with the clamp here.  
Control unit, cover removed  
5. Re-connect two connectors disconnected at step 3.  
6. Fasten eight screws to attach the control unit cover.  
7. Attach the connector seal (supplied) to the hole at the rear of the control unit.  
8. Drill a hole of 30 mm in diameter to pass the cable from the bottom of the control unit  
through the tabletop  
9. Attach the connector seal (supplied) to the hole at the bottom of the control unit when  
the above modification is not done.  
10.Fix the control unit referring to (2) or (3) on the previous page.  
Cable  
Cable  
Without KB fixing plate  
Control unit, side view  
With KB fixing plate  
1-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.4 Transceiver Unit  
The physical distance between the hull unit and the transceiver unit should be no more than  
5 m. The transceiver unit should be mounted on a mounting base (shipyard supply) whose  
dimensions are as shown in the outline drawing of the transceiver unit at the back of this  
manual. Reinforce the transceiver unit against vibration by stays extending from the  
eyebolts on the top of the unit. Fasten four bolts (M12, local supply) at the bottom of the  
transceiver unit to fix the unit to the mounting location.  
CHARGE  
BV ERR  
OV ERR  
FUSE  
Transceiver unit  
1.5 Grounding the Equipment  
Transceiver unit, junction box: Use copper strap (supplied).  
Processor unit:  
Use a ground wire (IV-8SQ).  
Junction box for hull unit:  
Use the wing bolt on the junction box.  
1-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.6 Installing the Attachment Flange (option)  
The attachment flange permits use of the tank for the CSH-20 series using the 1200 mm  
stroke transducer.  
Attachment flange Type: OP10-27, Code no: 000-067-050)  
Name  
Attachment flange  
O-ring  
Hex. nut  
Flat washer  
Spring washer  
Type  
10-077-5802  
CO 0318A (V585)  
M20 SUS304  
M20 SUS304  
M20 SUS304  
Code No.  
100-303-610  
000-166-370-10  
000-863-116  
000-864-136  
000-864-270  
Qty  
1
1
48  
24  
24  
Remarks  
Procedure  
1. Clean the hull unit flange, O-ring and O-ring groove. Coat them with a slight amount of  
grease.  
2. Use 48 hex. nuts, flat washers and spring washers to fasten the attachment flange to  
retraction tank.  
3. Place the O-ring in position on the attachment flange.  
To install the attachment flange and the hull unit, see paragraph 1.1.4.  
Hex. Bolt  
Flat Washer  
Hull Unit Flange  
O-ring  
Flat Washer  
Spring Washer  
Hex. Nut  
Attachment Flange  
O-ring  
Existing Tank  
Flat Washer  
Spring Washer  
Hex. Nut  
Attachment flange for 1200 mm stroke transducer, sectional view  
1-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.7 Cable Extension Kit (option)  
For extension of the transducer cable between the hull unit and the transceiver unit, use the  
cable extension kit (option), which includes a junction box. The kit is available in 5 m or 15  
m extension lengths. Below are the contents of each kit.  
Name: Cable Extension Kit, Type: FSV-305-5, Code No.: 000-067-072  
Name  
Type  
FSV-305  
Code No.  
000-067-032  
000-148-369-03  
000-145-360  
Qty  
1
Remarks  
Junction box  
10S2240  
10S2144  
1
5 m  
Cable assembly  
1
12.9 m  
Name: Cable Extension Kit, Type: FSV-305-15, Code No.: 000-067-073  
Name  
Type  
FSV-305  
Code No.  
000-067-032  
000-148-370-03  
000-145-361  
Qty  
1
Remarks  
Junction box  
10S2240  
10S2145  
1
15 m  
Cable assembly  
1
22.9 m  
Fasten the junction box to a bulkhead with 4 bolts (M6, local supply).  
Junction box  
1-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.8 Installing the Attachment Kit (option)  
The attachment kit permits use of the tank for the CSH-20 series using the 1600 mm stroke  
transducer and FSV-243E/244E.  
Attachment kit (Type: OP10-24, Code no.: 006-943-530)  
Name  
Type  
Code No.  
000-857-220  
000-857-221  
Qty  
24  
24  
Insulation gasket (1) MS-1000-67  
Insulation gasket (2) MS-1000-68  
1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount  
of grease. Place the O-ring in position on the tank flange.  
2. Lay the insulation gasket (1) on the top of the tank flange.  
3. Orient the hull unit so that the bow mark (inscribed) on its flange points toward the ship’s  
bow. Note that heading adjustment in the monitor is required if the bow mark does not  
face the ship’s bow.  
4. Confirm that the O-ring and the insulation gasket (1) are in position.  
5. Place the hull unit on the tank.  
6. Seven of the 24 bolt holes on the hull unit flange have already been fitted with bolts  
(stern side). Insert the insulation gasket (2) into the bolt holes of the tank flange to which  
these seven bolts are fitted.  
7. Coat every bolt, washer and nut with a slight amount of grease to ease removal. Fit the  
insulation gasket (2) into the bolt holes of the tank flange. Fasten the hull unit to the  
retraction tank with insulation gasket (2), flat washers, spring washers and hex bolts.  
8. Reinforce the hull unit against vibration by extending stays to the ship’s hull from the two  
eye bolts at the top of the hull unit, referring to the figure at the top of page 1-8.  
1-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hex. nut  
Spring washer  
Flat washer  
Flange of hull unit  
O-ring  
Flange of hull unit  
O-ring  
Insulation gasket (1)  
Insulation gasket (1)  
Insulation gasket (2)  
Insulation gasket (2)  
Flat washer  
Flat washer  
Spring washer  
Hex. nut  
Hex. bolt  
Spring washer  
O-ring  
Flat washer  
O-ring  
Insulation gasket  
Insulation gasket (2)  
Flat washer  
Retraction tank  
Hex. bolt  
Hex. nut  
Spring washer  
Bow side  
(17 locations)  
Stern side  
(Seven locations)  
Installation of attachment kit  
1-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. WIRING  
2.1 How to Use the Crimping Tool, Pin Extractor  
A special crimping tool is necessary for connection of wires to the contact pins of the 38P  
connector. The pin extractor removes the contact pin from the connector body. This  
paragraph describes how to crimp and extract the contact pin.  
Contact Pin  
60-8017-0313-00-339  
(000-519-542)  
Pin Extractor  
06-1877-04  
(000-519-595)  
Crimping Tool  
06-1001-016  
Crimping tool, contact pin, pin extractor  
2.1.1 How to use the crimping tool  
1. Remove the vinyl sheath by 3 to 4 mm to expose  
the core.  
2. Hold the crimping tool horizontally and insert the  
contact pin with its slit facing downward into the  
crimp hole on the crimping tool.  
3. Insert the wire onto the contact pin and squeeze  
the handle until the rachet releases. (The wire  
should be placed deep enough into the contact pin  
so that its end comes in contact with the stopper  
plate of the crimping tool.) With crimping  
completed, pull the wire while holding the contact  
pin to make sure that it is tightly fastened.  
2.1.2 How to use the pin extractor  
If a contact pin is inserted into an incorrect hole on  
the connector body, remove it with the pin extractor.  
1. Push the pin extractor into the pin hole from the  
side opposite to the pin inserting side.  
2. Push in the head of the pin extractor. The retaining  
spring comes free and the contact pin can be  
removed.  
2
1
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 Wiring  
10S2077 (10 m)  
FSV-30  
CONTROL UNIT FSV-3001  
Monitor  
(Local supply)  
Transceiver  
unit  
Control unit  
Monitor cable  
(Local supply)  
Control unit  
External  
monitor  
*1: If connector may loosen by  
vibration monitor cable may also  
be connected inside.  
*1  
*2  
Processor unit clamp  
PROCESSOR UNIT  
FSV-3002/3002S  
DPYCY-1.5  
100/110/115/  
220/230 VAC  
1φ, 50/60 Hz  
TRANSCEIVER UNIT  
FSV-301  
10S2078 (8 m)  
*4 *5  
*3  
220 VAC  
3φ, 50/60 Hz  
100/110/115/  
220/230 VAC  
1φ, 50/60 Hz  
DPYCYS-2.5 *2  
*2  
TPYCY-4  
HULL UNIT  
FSV-303  
(1200 mm stroke)  
FSV-304  
(1600 mm stroke)  
10S2223 (14.6 m)  
*4 *5  
*2: Japan Industrial Standard cable  
*3: The same type of connector is fitted at each end, however the connector where the amount of sheath  
removed is greater should be connected to the transceiver unit.  
*4: When running the cables of 10S2078, 10S2223 refer to next page.  
*5: When using cable for extension kit, the length of the cable between the transceiver unit  
and the hull unit is 5 m or 10 m.  
Wiring  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transceiver unit side  
P2  
(40 pin)  
0.38 m  
P1  
(34 pin)  
0.07 m  
Clamp point  
0.6 m  
Clamp point  
.
10S2223  
14.6 m  
14.0 m  
7.2 m  
10S2078  
8 m  
Hull unit side  
Clamp point  
0.07 m  
0.28 m  
Raise/lower control box  
of the hull unit side  
Note that the amount of cable inside the cable clamp on the cable between the hull unit and  
transceiver unit may be shorted depending on cable length.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3 Processor Unit  
Cables (10S2074, 10S1258-1 and control cable) from the various units are connected to the  
CONE Board (10P6905) in the processor unit.  
NOTICE  
Divide cables attached to the back of the  
processor unit between right and left side.  
Tie each group with a cable tie at the  
position 15 cm from connectors.  
This is necessary to prevent cable stress.  
15 cm  
Cable tie  
Processor unit, rear view  
2.3.1 10S1258-1 cable  
This cable runs between the processor unit and transceiver unit.  
Shield  
Anticorrosive Sheath  
1. BLK  
9. BLK/GRY  
17. BRN/GRY  
18. BRN/WHT  
19. RED/ORG  
8
2
1
9
2. BLK/BRN  
3. BLK/RED  
4. BLK/ORG  
5. BLK/YEL  
6. BLK/GRN  
7. BLK/BLU  
8. BLK/PPL  
10. BLK/WHT  
11. BRN/RED  
12. BRN/ORG  
13. BRN/YEL  
14. BRN/GRN  
15. BRN/BLU  
16. BRN/PPL  
19  
10  
18  
17  
3
4
7
6
11  
12  
13  
5
16  
14  
15  
Armor  
1:  
Coaxial cable  
2 to 19: Twisted pair cable  
Cable type 10S1258-1, sectional view  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fabrication of connector 00-8016-038-313761HV (CN-A101)  
320  
Anticorrosive  
45  
40  
Shield  
Sheath  
Vinyl Sheath  
Armor  
Core  
Insulating Tape  
After exposing cores,  
wind shield around the armor.  
Fabrication of cable for connector 00-8016-038-313761HV  
Guide Pin A  
Guide Pin B  
Position No.  
Guide Pin B  
(Small)  
Guide Pin A  
(Large)  
Assembling 38P connector  
Positioning guide pins  
Guide pins of the connector identify the mating receptacle. They are;  
Guide pin A (Large): 1  
Guide pin B (Small): 1  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.2 Power cable  
Attach the NCS-253-P connector (CN-A110) to the power cable DPYCY-1.5 (Japan  
Industrial Standard (JIS) cable) or the equivalent. Attach the connector to the processor unit.  
Cable DPYCY-1.5  
Armor  
Vinyl  
sheath  
Conductor  
S = 1.5 mm  
Use cable DPYCY-1.5  
(Japan standard cable)  
or equivalent cable.  
2
= 1.56 mm  
Assembling connector NCS-253-P  
2.3.3 Control cable  
Attach the control cable (10S2074 or 10S2075) to the CN-A103 connector in the processor  
unit.  
2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.4 Optional equipment  
With connection of a navigator and electronic fishing equipment, the FSV-30 provides true  
motion presentation, target lock, echo sounder picture, FNZ marker presentation, and digital  
indication of position, water temperature and depth.  
Use the SRCN connectors (optionally supplied, Type: CP10-4801, Code no.: 006-934-240)  
to connect equipment to the rear of the processor unit. Refer to the interconnection diagram  
at the back of this manual.  
Cable list  
Outline of core  
Simple  
w/shield  
Twisted  
Sectional view of cables  
02S8040  
No.  
1
Color  
WHT/BLU  
BLK  
9 mm  
2
3
PNK  
Shield  
4
GRN  
5
ORG  
YEL  
6
7
RED  
CO-SPEVV-SB-C 0.2sq, 5P  
No.  
1
Color  
YEL/BLK  
2
YEL/WHT  
YEL/RED  
YEL/BLU  
Shield  
Armor  
14 mm  
3
4
5
YEL/GRN  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
J5 (CIF1)  
J7 (GYRO)  
J8 (LOG)  
J10 (FNZ)  
: SRCN6A13-5P  
: SRCN6A16-10P  
: SRCN6A13-3P  
: SRCN6A21-10P  
Cable with armor  
J13 (EXT-KP) : SRCN6A21-10S  
8 cm  
2 cm  
1 cm  
Armor  
Vinyl sheath  
Shield  
3 mm  
Clamp fixing screw  
Solder unused cores and  
earth to braided shield.  
Clamp  
Set screw  
Wind shield  
tape.  
Solder earth wire.  
Connector case  
Soldering side  
Attach conector at  
shield to ground.  
Wind vinyl tape.  
J9 (ES1)  
J12 (ES2/NET) : SRCN6A16-10P  
: SRCN6A16-7P  
Cable without armor  
2 cm  
3mm  
Shield  
Vinyl sheath  
Clamp fixing screw  
Solder unused cores and  
earh wire to braided shieeld.  
Clamp  
Set screw  
Vinyl sheath  
Wind vinyl tape  
Connector case  
Soldering-side  
2-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Synchronizing with echo sounder or other sonar  
To synchronize the transmission of the FSV-30 with an echo sounder or other type of sonar,  
make connections as shown below.  
For current driven KP input  
Processor  
unit  
EXT-KP  
KP signal  
8
9
E/S  
Sonar  
EXT-KP-IN-H  
EXT-KP-IN-C  
For voltage driven KP (12 V) input  
Processor  
unit  
EXT-KP  
KP signal  
10  
7
E/S  
Sonar  
EXT-12VKP-H  
0V  
Voltage driven KP output  
KP signal  
Processor  
EXT-KP  
unit  
1
2
3
4
5
6
INTKP1  
GND  
INTKP2  
GND  
INTKP3  
GND  
E/S,  
Sonar,  
Current  
indicator  
Menu setting  
See EXT KP INPUT on page 3-9.  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4 Transceiver Unit  
2.4.1 Fabrication of connector 00-8016-038-313761HV (CN-B101)  
400  
Anticorrosive  
45  
40  
Shield  
Sheath  
Vinyl Sheath  
Armor  
Core  
Insulating Tape  
After exposing cores,  
wind shield around the armor.  
Fabrication of cable for 00-8016-038-313761HV  
Shorten the unused wires appropriately and treat their ends with vinyl tape to prevent short  
circuit.  
Guide Pin A  
Guide Pin B  
Position No.  
Guide Pin B  
(Small)  
Guide Pin A  
(Large)  
Assembling 38P connector  
Positioning guide pins  
Use the tool shown below to position guide pins.  
Connector  
Tool  
CN-B101  
Guide Pin  
Guide Pin A (large)  
Guide Pin B (small)  
1
1
2-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13-L  
CN-B210  
CN-B209  
CN-B208  
CN-B207  
CN-B206  
CN-B205  
CN-B204  
CN-B203  
CN-B202  
CN-B201  
6962  
6963  
CN-B101  
CN-B102  
1 6 - L  
TRX-10  
TRX-9  
TRX-8  
TRX-7  
TRX-6  
TRX-5  
TRX-4  
TRX-3  
TRX-2  
TRX-1  
SB-1909  
EDS3  
0 7 - L  
E D S 3  
SM18P  
J203  
EL12P  
J201  
EL9P  
SM8P  
SM12P  
J205  
EL3P  
J601  
F601  
MAIN  
F602  
J202  
J204  
J206  
5A  
5A  
I
MAINTENANCE  
I
INPUT  
TB-B101  
Maintenance  
Use Only.  
(Should be OFF  
for Normal  
operation.)  
100/110/115  
/220/230 VAC  
:15A  
50/60Hz  
1
2
J301  
YL8P  
J302  
SM12P  
J303  
EL4P  
S603  
H
S604  
H
S605  
H
INPUT(TB-B101) S603 S604 S605  
100V  
110V  
115V  
220V  
230V  
L
L
L
H
L
L
L
L
H
H
TB-B101  
H
H
H
H
15A  
15A  
H
L
L
L
To Processor Unit  
(cable 10S1258-1)  
To Hull Unit  
(cable 10S2078)  
To Power Source  
Transceiver unit, inside view  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4.2 Fabrication of power cable type DPYCYS-2.5 (TB-B101)  
Fabricate the cable DPYCYS-2.5 as below for connection to the power source.  
Cable DPYCYS-2.5  
Armor  
Vinyl  
sheath  
Conductor  
S = 4 mm2  
= 2.55 mm  
140  
35  
30  
FV2-4 (2 pcs)  
Anticorrosive  
sheath  
Vinyl sheath  
Amor  
Fabrication of cable type DPYCYS-2.5  
2.4.3 Hull control cable (10S2078)  
Connect the hull control cable (10S2078) to the CN-B102 in the transceiver unit.  
Note: The same type of connector is fitted at each end, however the connector which has a  
larger portion of its sheath removed should be connected to the transceiver unit.  
2-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4.4 Wiring in transceiver unit  
1. Open the transceiver unit cover.  
2. Plug the P1 and P2 connectors at the end of signal cables into the proper receptacles in  
the transceiver unit, referring to the interconnection diagram at the back of this manual.  
3. Lead the signal cables into the transceiver unit appropriately.  
4. Fasten the cables with cable clips after wiring the hull unit.  
From right to left B201 to B210  
P2  
(40 pin)  
13-L  
P1  
(34 pin)  
CN-B210  
CN-B209  
CN-B208  
CN-B207  
CN-B206  
CN-B205  
CN-B204  
CN-B203  
CN-B202  
CN-B201  
6962  
6963  
1 6 - L  
TRX-10  
TRX-9  
TRX-8  
TRX-7  
TRX-6  
TRX-5  
TRX-4  
TRX-3  
TRX-2  
TRX-1  
SB-1909  
EDS3  
0 7 - L  
10S2223  
Cable clip  
E D S 3  
SM18P  
J203  
EL12P  
J201  
EL9P  
SM8P  
SM12P  
J205  
EL3P  
J601  
F601  
MAIN  
F602  
J202  
J204  
J206  
5A  
5A  
I
MAINTENANCE  
I
INPUT  
TB-B101  
Maintenance  
Use Only.  
(Should be OFF  
for Normal  
operation.)  
100/110/115  
/220/230 VAC  
:15A  
50/60Hz  
1
2
J301  
YL8P  
J302  
SM12P  
J303  
EL4P  
S603  
H
S604  
H
S605  
H
INPUT(TB-B101) S603 S604 S605  
100V  
110V  
115V  
220V  
230V  
L
L
L
H
L
L
L
L
H
H
H
H
H
H
15A  
15A  
H
L
L
L
Secure  
here with  
metal clamp.  
Fix signal cables with clamp.  
Transceiver unit  
10  
9
8
7
6
5
4
3
2
1
Cable  
number  
Transceiver unit, top view  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5 Cable Extension Kit  
The length of the cable between the hull unit and transceiver unit is 5 meters. If a longer  
cable is required, use the cable extension kit, which consists of a junction box and a 5 or 15  
meter cable.  
Connect the transducer cable 10S2223 to the junction box, and connect the transceiver unit  
to the junction box with the cable 10S2240 (5 or 10 m).  
Replace the cable (10S2078, 8 m) connected between the hull unit and transceiver unit with  
the cable 10S2144 (12.9 m) or 10S2145 (22.9 m). Those cables are supplied with the  
extension cable kit.  
2.5.1 Junction box  
Connect the extension cable 10S2240 to JCTN1 and JCTN2 inside the junction box. Also,  
connect the transducer cable 10S2223. Refer to interconnection diagram for wiring details.  
1. Open the junction box cover.  
2. Unfasten the cable clamps.  
P1  
P3  
P3  
P1  
JCTN1  
Board  
Connect to  
the J1 in  
JCTN1 Board  
Connect to  
the J2 in  
JCTN1 Board  
Connect to  
the J20 in  
JCTN1 Board  
Connect to  
the J19 in  
JCTN1 Board  
J1  
J20J19  
J20 J19  
J2 J1  
J2 J1  
J1  
JCTN2  
Board  
P2  
P2  
P4  
P4  
Connect to  
the J2 in  
JCTN2 Board  
Connect to  
the J20 in  
JCTN2 Board  
Connect to  
the J1 in  
JCTN2 Board  
Connect to  
the J19 in  
JCTN2 Board  
CSK  
clamp  
Cable from  
hull unit  
(10S2223)  
Cable from  
transceiver unit  
(10S2240)  
Cable from  
hull unit  
(10S2223)  
Cable from  
transceiver unit  
(10S2240)  
Cable clamp  
Signal cables  
(10S2223)  
Junction box  
from hull unit  
10 9  
10  
8
8
7
6
5
4
3
2
2
1
1
9
7
6
5
4
3
Signal cables (10S2240) from transceiver unit  
("JUNCTION BOX" display side)  
Junction box, cover removed  
2-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Lead in cable thru the appropriate location on the cable clamp and fix cable with  
appropriate CKS clamp. Connect each cable to circuit board as shown in the figure on  
the previous page.  
Signal cable (10S2240) connects to “JUNCTION BOX” display side.  
4. Lay the shield of each cable in the cable clamp.  
5. Fasten the cable clamps.  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5.2 Raise/Lower control box  
Connect the power cable (3φ) and the transceiver unit cable (10S2078) as shown below.  
CN-C101  
Connect the transceiver  
cable (10S2078) here.  
Cable TPYCY-4  
Sheath  
TB-C101  
Connect the power cable TPYCY-4  
Armor  
(Japan Industrial Standard) or the  
equivalent cable to this terminal board.  
Vinyl  
sheath  
LED (Red)  
For detection of phase reversal on  
3 phase power cable  
Conductor  
S = 4 mm2  
= 2.55 mm  
Confirm LED after completing the installation. The LED lights (in red) if power connection is  
correct. If it is off, turn off power from the mains switchboard, check the cable connection  
and recheck the LED. The hull unit does not work if this connection is wrong.  
Normal phase: LED lights (in red).  
Phase reversal: LED does not light.  
Power cable (3φ)  
TPYCY-4  
Cable from  
transceiver unit  
10S2078  
Raise/lower control box, cover removed  
2-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
100  
25  
20  
M4(yellow) x 3  
FV5.5-4  
Vinyl  
sheath  
Sheath  
Armor  
(Clamp here by cable clamp.)  
Power cable fabrication  
2-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.6 Input Voltage and Fuses  
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a  
10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions  
and fuses as below.  
Input voltage  
Set the toggle switches S603, S604 and S605 according to input voltage, referring to the  
table below.  
Input  
S603  
S604  
S605  
Default setting  
(TB-B101)  
100 V  
L
L
L
L
L
110 V  
115 V  
220 V  
230 V  
H
H
H
H
H
L
L
H
H
H
Default setting  
Fuses  
Change the fuse in F601 and F602 according to input voltage, referring to the table below.  
Fuse  
Input  
(TB-B101)  
Default  
setting  
F601  
20A  
F602  
20A  
WARNING  
Use the proper fuse.  
100 V  
110 V  
115 V  
220 V  
230 V  
Use of a wrong fuse can result in damage  
to the equipment or cause fire.  
Default  
setting  
10A  
10A  
Marking the label  
After setting toggle switches and changing the  
fuses, mark the voltage which applies on the label  
on the inside of the cover. In the example shown  
right, 100 V is marked so 20A fuses must be used.  
FUSE  
F601  
FUSE  
F602  
INPUT  
FUSE  
(TB-B101)  
F601 F602  
100V  
110V  
115V  
220V  
230V  
20A  
10A  
20A  
10A  
2-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. ADJUSTMENT AND CHECK  
3.1 Hull Unit Check  
Note: Before conducting this check (at the dry dock) transmission must be stopped. Default  
setting of TX power is OFF. Confirm that transmission is off as follows:  
1. Turn on the power, and then press the [MENU] key to show the main menu.  
MENU  
QUIT  
TX PULSE LENGTH-H : 9  
TX POWER-H  
TVG-NEAR-H  
TVG-MEDIUM-H  
TVG-FAR-H  
: 9  
: 0  
: 0  
: 0  
AGC-H  
: 0  
2ND AGC-H  
ECHO AVERAGE-H  
COLOR-H  
: 0  
: 0  
: COLOR 1  
COLOR RESPONSE-H : COLOR CURVE 3  
H-SCAN SETTING...  
V-SCAN SETTING...  
OTHERS...  
Main menu  
2. Use the trackball to choose OTHERS and press the [MENU] key.  
MENU  
QUIT  
QUIT  
OTHERS  
ES1 SETTING...  
ES2 SETTING...  
ERASE MARKS...  
DISPLAY SETTING...  
ALARM & AUDIO...  
PRESET, MEMORY CARD...  
INITIAL SETTING...  
OTHERS menu  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Choose INITIAL SETTING and press the [MENU] key.  
CAUTION  
YES  
NO  
THIS ITEM IS DEFINED AS NON-  
CHANGEABLE ITEM, ARE YOU  
SURE TO CHANGE IT TO CHANGEABLE ?  
4. Choose YES and press the [MENU] key.  
MENU  
OTHERS  
QUIT  
QUIT  
QUIT  
INITIAL SETTING  
MARK DISPLAY...  
MARK SIZE...  
DATA DISPLAY...  
CURRENT VEC & WIND...  
NET SONDE SETTING...  
NET SHOOT SETTING...  
TARGET LOCK...  
STABILIZATION...  
TEST...  
INITIALIZATION...  
INITIAL SETTING menu  
5. Choose TEST and press the [MENU] key.  
MENU  
QUIT  
QUIT  
QUIT  
QUIT  
OTHERS  
INITIAL SETTING  
TEST  
BOARD TEST...  
PANEL TEST...  
TEST PATTERN...  
RX TEST...  
NOISE TEST...  
TX  
: OFF  
TEST menu  
6. Choose TX and press the [MENU] key.  
7. Choose OFF (if it is not already selected) and press the [MENU] key.  
8. Choose QUIT at the top of the menu screen and press the [MENU] key.  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to check the hull unit  
1. Press the POWER (|) switch on the control unit to turn on the equipment. Confirm that  
“ ON” lamp above the POWER switch and the switch light.  
ª
Transducer switches of the control unit  
2. Confirm that the 5V and UP lamps on the raise/lower control box are lit.  
3. Remove the cover of the raise/lower control box and use a multimeter to measure the  
following voltages:  
Terminal  
Terminal No.  
Voltage  
TB-C101 (1) – (2), (6) – (7)  
(2) – (3), (7) – (8)  
220 VAC  
220 VAC  
220 VAC  
(1) – (3), (6) – (8)  
4. In the raise/lower control box, set the TEST/NORMAL switch to TEST. Press the  
[DOWN] switch to confirm that the transducer lowers. Also, while the transducer is being  
lowered, check that the MD LED lights when the MD L. SW kicks. Note that the MD L.  
SW does not stop the transducer when the TEST/NORMAL switch is in the TEST  
position.  
TEST  
OFF  
NORMAL  
5V  
L.SW  
UP MD DN  
UP  
DOWN  
Control unit (in hull unit)  
5. Press and release the [DOWN] switch. Confirm that the transducer stops at the moment  
the switch is released.  
6. Press the [DOWN] switch again. Confirm that the transducer stops at the moment the  
lower limit switch kicks.  
7. Confirm that the [UP] switch operates in a similar manner.  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Check that LEDs on the panel of the raise/lower control box light as follows:  
1) UP, MD and DN LEDs light when corresponding limit switch is kicked.  
2) UP and DOWN LEDs light while UP and DOWN switches are pressed and extinguish when  
the switches are released.  
3) Set the TEST/NORMAL switch to NORMAL.  
9. At the control unit, press the (mid position) switch. Confirm that the lamp above the  
ª
switch blinks while the transducer is being lowered, a short beep sounds when the mid  
limit switch kicks, and the lamp lights when the transducer is lowered to the mid position.  
10.Press the  
switch. Confirm that the lamp above the switch blinks while the transducer  
ª
is being lowered, a short beep sounds when the mid limit switch is kicked, and the lamp  
lights when the transducer is fully lowered.  
11. Press the switch. Confirm that the lamp above the switch blinks while the transducer  
©
is being raised, a short beep sounds when the mid limit switch is kicked, and the lamp  
lights when the transducer is fully raised.  
12.Press the OFF switch. Confirm that the transducer is completely retracted and then the  
power is turned off.  
13.With the transducer lowered (mid or fully lowered), confirm that the transducer is raised  
when or OFF is pressed.  
©
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2 Heading Adjustment  
When the BOW mark on the flange of the hull unit cannot be directed toward ship’s bow,  
adjust the heading so an echo which is dead ahead appears dead ahead on the display.  
1. Referring to the previous section, set the TX (transmission) to ON.  
2. Locate a target in the bow direction (buoy, for example) and display it on a near range. If  
the target appears at 12 o’clock the heading alignment is correct. If it does not, measure  
the error and go to step 2.  
Buoy  
If target's on-screen  
position is right of ship's  
bow for example, heading  
is skewed left.  
Heading adjustment  
3. Turn off the power and then turn it on again while pressing and holding down the  
[MENU] key. Release the [MENU] key after the self-test screen appears. After the picture  
appears, press the [MENU] key three times to open the SYSTEM menu.  
SYSTEM MENU  
QUIT  
INTERFACE SETTING..  
EXT DATA SETTING..  
OWN SHIP MARK..  
TEST&INITIALIZATION..  
TX/RX SETTING..  
TX/RX SETTING - H..  
TX/RX SETTING - V..  
OTHERS..  
SYSTEM menu  
4. Use the trackball to choose OTHERS and press the [MENU] key.  
5. Choose HEADING ADJUST and press the [MENU] key.  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MENU  
QUIT  
QUIT  
OTHERS  
LANGUAGE  
: ENGLISH  
: 0  
QUIT  
CANCEL  
HEADING ADJUST  
ES2 SELECT  
: ES  
ES DRAFT OFFSET : 0.0 m  
EVENT KEY  
: EVENT  
AUTO TILT  
: WIDE  
: H/V INTERLOCK  
SELECT USER PROG  
TRACKBALL SPEED  
HULL UNIT STROKE  
: NORMAL  
: 1200mm  
OTHERS menu, HEADING ADJUST  
6. Choose or to choose direction (plus or minus, respectively) in which to increment  
or decrement setting and then press the [MENU] key to set. Each pressing of the  
[MENU] key changes the setting in increments of 1°. The setting range is -180° to +179°.  
7. Choose QUIT to finish the adjustment and press the [MENU] key.  
8. Choose QUIT at the top of the menu screen and press the [MENU] key to close all  
menus.  
3-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3 Configuring Own Ship Mark  
Set own ship’s dimensions and the location of the transducer to accurately display the own  
ship mark on the display.  
1. Press the [MENU] key to display the SYSTEM menu.  
SYSTEM MENU  
QUIT  
INTERFACE SETTING..  
EXT DATA SETTING..  
OWN SHIP MARK..  
TEST&INITIALIZATION..  
TX/RX SETTING..  
TX/RX SETTING - H..  
TX/RX SETTING - V..  
OTHERS..  
System menu  
2. Use the trackball to choose OWN SHIP MARK and press the [MENU] key.  
MENU  
QUIT  
QUIT  
OWN SHIP MARK  
: 75m  
: 20m  
: 15m  
: 0.0m  
SHIP'S LENGTH  
SHIP'S WIDTH  
TD POSITION 1  
TD POSITION 2  
OWN SHIP MARK menu  
3. Use the trackball to choose SHIP’S LENGTH.  
4. Press the [MENU] key to show the setting window.  
MENU  
QUIT  
QUIT  
OWN SHIP MARK  
QUIT  
CANCEL  
: 75m  
: 20m  
: 15m  
: 0.0m  
SHIP'S LENGTH  
SHIP'S WIDTH  
TD POSITION 1  
TD POSITION 2  
OWN SHIP MARK menu, setting window  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Choose or and then operate the [MENU] key to set the ship’s length (15 to 150 m).  
6. Choose QUIT to finish the setting.  
7. Set the SHIP’S WIDTH (5 to 30 m), TD POSITION 1 (5 to 50 m) or TD POSITION 2  
(-10.0 to 10.0 m) similarly.  
TD POSITION 1: Set the transducer’s distance from the bow.  
TD POSITION 2: Set the transducer’s distance from the keel. Choose [+] for starboard,  
[-] for port.  
8. Choose QUIT at the top of the menu screen and press the [MENU] key to close all  
menus.  
TD Position 1  
Ship's  
Length  
TD Position 2  
(Negative value  
for port)  
Ship's Width  
Ship shape description  
3-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4 Other SYSTEM Menu Items  
This section mainly shows you how to set up according to external equipment connected.  
Default settings are underlined.  
3.4.1 INTERFACE SETTING menu  
MENU  
QUIT  
QUIT  
INTERFACE SETTING  
: 4800 bps  
: 4800 bps  
: 4800 bps  
: 19200 bps  
NMEA 1 BAUD RATE  
NMEA 2 BAUD RATE  
CIF BAUD RATE  
AUX BAUD RATE  
: DISABLE  
EXT KP INPUT  
: NEGATIVE  
EXT KP OUTPUT  
INTERFACE SETTING menu  
NMEA 1 BAUD RATE  
Set the transmission rate for the NMEA 1 port.  
(4800 bps, 9600 bps, 19200 bps, 38400 bps)  
NMEA 2 BAUD RATE  
Set the transmission rate for the NMEA 2 port.  
(4800 bps, 9600 bps, 19200 bps, 38400 bps)  
CIF BAUD RATE  
Set the transmission rate for the CIF port. If the CS-120A is connected, choose “2400 bps”.  
(2400 bps, 4800 bps, 9600 bps, 19200 bps)  
AUX BAUD RATE  
Set the transmission rate for the AUX port. (2400 bps, 4800 bps, 9600 bps, 19200 bps)  
EXT KP INPUT  
Set the input logic of KP from an external equipment. (DISABLE, POSITIVE, NEGATIVE)  
DISABLE: No use external KP.  
POSITIVE: Synchronize with leading edge of input pulse.  
NEGATIVE: Synchronize with trailing edge of input pulse  
Note: To transmit with external KP, set the TX INTERNAL to “0” in the H-SCAN SETTING  
menu.  
EXT KP OUTPUT  
Choose the KP output logic, POSITIVE or NEGATIVE. (POSITIVE, NEGATIVE)  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4.2 EXT DATA SETTING menu  
MENU  
QUIT  
QUIT  
EXT DATA SETTING  
DATE&TIME  
HEADING  
: CIF  
: AD10S  
LOG PULSE  
: 200p/NM  
SPEED&COURSE  
SPEED SENSOR  
LAT/LON  
: NMEA  
: GPS/DR  
: NMEA  
POSITIONING SENSOR  
: AUTO SEL.  
WATER DEPTH  
WATER TEMP.  
: NMEA  
: NMEA  
WATER CURRENT  
WIND  
: CIF  
: CIF  
NET DEPTH  
: PULSE  
EXT DATA SETTING menu  
DATE & TIME  
Choose the input format for data and time data. (NONE, CIF, NMEA)  
HEADING  
Choose the input format for heading data. (NONE, AD10S, CIF, NMEA)  
LOG PULSE  
Set the log pulse rate for the log signal. (200 p/NM, 400 p/NM)  
SPEED & COURSE  
Choose the input format for ship’s speed and course data. When choosing the  
LOG&HEADING, the heading data is used instead of the course data.  
(NONE, LOG&HEADING, CIF, NMEA)  
SPEED SENSOR  
Choose the input format for speed and course data. This setting is ineffective when  
LOG&HEADING is selected as speed and course source.  
(NONE, GPS/DR, DOPPLER/DR)  
LAT/LON  
Choose the input format for ship’s position data. (NONE, CIF, NMEA)  
POSITIONING SENSOR  
Choose the type of the navigator to use. For AUTO SEL., the priority is GPS/DR>LORAN-C.  
(LORAN-C, GPS/DR, AUTO SEL.)  
3-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER DEPTH  
Choose the input format for depth data. (NONE, CIF, NMEA)  
WATER TEMP.  
Choose the input format for water temperature data. (NONE, CIF, NMEA)  
WATER CURRENT  
Choose the input format for water current data. (NONE, CIF, NMEA)  
WIND  
Choose the input format for wind data. (NONE, CIF, NMEA)  
NET DEPTH  
Choose the input format for net depth data. (NONE, CIF, PULSE)  
Data sentences (NMEA 0183, FURUNO proprietary)  
NMEA Input  
Position (L/L)  
Heading  
Course  
GGA, GLL, GNS, RMA, RMC  
HCC, HCD, HDG, HDM, HDT  
VTG  
Speed  
VBW, VHW  
Current  
CUR, VDR  
Depth  
DBS, DBT, DPT  
Temperature  
Wind  
MTW  
MWV  
Date Time  
GPS gyro  
ZDA  
Att (FURUNO proprietary data sentence)  
NMEA Output  
Position  
TLL  
FURUNO proprietary data sentences (all output)  
Fish school speed  
Relative bearing, range depth and speed of fish school  
Relative bearing, range and depth of position tracking mark  
Bearing, range and depth of event mark  
Bearing, range, depth and volume of fish estimate mark  
Bearing, range, depth and speed of fish school mark  
Bearing and range of net shoot mark  
FKV  
TFM  
TLM  
EVT  
FMG  
FVC  
SHT  
Scattering strength (SV), area, volume and abundance of fish school TLF  
Scan setting parameter (1 to 6) at each Tx SD3 - SD8  
3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4.3 OTHERS menu  
MENU  
QUIT  
QUIT  
OTHERS  
LANGUAGE  
: English  
HEADING ADJUST  
ES2 SELECT  
: 0  
: ES  
ES DRAFT OFFSET : 0.0 m  
EVENT KEY  
: EVENT  
AUTO TILT  
: WIDE  
: H/V INTERLOCK  
: NORMAL  
: 1200mm  
SELECT USER PROG  
TRACKBALL SPEED  
HULL UNIT STROKE  
OTHERS menu  
LANGUAGE  
Choose the language to use. (JAPANESE, ENGLISH)  
HEADING ADJUST  
See “3.2 Heading Adjustment”.  
ES2 SELECT  
Choose the equipment connected to the ES2 port; echo sounder or net recorder.  
(ES, NET REC)  
ES DRAFT OFFSET  
When connecting an echosounder, you may enter the ship’s draft if you prefer to display  
depth from the draft rather than depth from the transducer. (0.0 m to 10.0 m, increments of  
0.1 m)  
EVENT KEY  
Choose the key to use to enter own ship’s position, EVENT or SHOOT. When choosing  
SHOOT, the shoot function becomes inoperative. (EVENT, SHOOT)  
AUTO TILT  
Choose the range for the auto tilt form WIDE (±2 to 10°, ±4 to 16°, ±6 to 20°) or NARROW  
(±1 to 4°, ±2 to 6°, ±3 to 8°). (WIDE, NARROW)  
SELECT USER PROG  
Choose whether to program horizontal and vertical displays together or individually, by the  
USER PROG control. H/V INTERLOCK, the default setting, commonly applies control  
settings to the horizontal and vertical displays. H/V INDVIDUAL enables individual  
adjustment of horizontal and vertical displays.  
3-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRACKBALL SPEED  
Choose the speed of trackball movement (inside menu window only).  
(SLOW, NORMAL, FAST)  
HULL UNIT STROKE  
Choose the stroke length of the hull unit. (1200 mm, 1600 mm).  
3.5 CONE Board Setting in the Processor Unit  
Adjust the potentiometers on the CONE Board in the processor unit, referring to the table  
shown below.  
Location Name  
No.  
Resistance  
value  
Function  
Adjustment  
R118  
ALARM  
10 kΩ  
Adjust the volume of audio  
alarm.  
CW: Large  
CCW: Small  
R119  
ES2_OFF  
1 kΩ  
Adjust ES2 signal offset.  
Adjust ES2 signal gain.  
Adjust ES1 signal offset.  
Adjust ES1 signal gain.  
CW: Noise decrease  
CCW: Noise increase  
CW: Gain increase  
CCW: Gain decrease  
CW: Noise decrease  
CCW: Noise increase  
CW: Gain increase  
CCW: Gain decrease  
R167  
R168  
R209  
ES2_GAIN  
ES1_OFF  
ES1_GAIN  
10 kΩ  
1 kΩ  
10 kΩ  
3.5.1 Adjustment of signal level (echo sounder connected)  
Adjusts the output level of the echo sounder on the CONE Board as below.  
1. Choose an echo sounder display (ES1 or ES2) from the menu.  
2. For ES1, adjust R168 to suppress noise, and then adjust R209 so that the picture  
condition is similar to that of connected echo sounder connected to the FSV-30.  
3. For ES 2, adjust R119 to suppress noise, and then adjust R167 so that the picture  
condition is similar to that of echo sounder connected to the FSV-30.  
3.5.2 Adjusting the volume of the audio alarm  
The volume of the audio alarm cannot be adjusted from the control unit. If necessary, adjust  
R118 on the CONE Board to choose appropriate volume.  
3-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.6 DIP Switch Setting  
J496, J497  
AC  
DC  
DCON board (10P6984 or 10P6984A)  
IFES board (10P6983)  
J496  
J497  
IFES  
SCAN  
SCAN2  
DUAL  
DCON  
J1  
Processor unit, inside view  
3.6.1 CIF2/NMEA2 connector interface selection  
The signal format for the CIF2/NMEA2 port (at the back of the processor unit) can be set for  
CIF or NMEA by DIP switch S2-8 on the IFES Board (10P6983). The default format is OFF  
(CIF).  
DIP switch setting  
S2-#8: ON  
Format  
NMEA  
CIF  
S2-#8: OFF  
S2  
IFES Board (10P6983)  
3-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.6.2 Choosing echosounder signal  
There are two kinds of echosounder signals, AC signal and DC signal. Set the appropriate  
jumper on the CONE board as below according to the input port. The default setting is AC.  
See page 3-14 for parts location.  
Input port  
ES1  
Jumper  
J497  
ES2/NET  
J496  
Note: The SIGOUT (AC signal) terminal and REC terminal (DC signal) in the output port  
are provided for a FURUNO echosounder. Therefore, when using the SIGOUT  
terminal, it is not necessary to change the above-mentioned jumper setting.  
3-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(This page intentionally left blank.)  
3-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. CONNECTING THE EXTERNAL  
INTERFACE CS-120A  
When upgrading from the CSH-20 series sonar, the External Interface CS-120A can be  
used. Connect the CS-120A to the processor unit as shown on the next page. However, we  
recommend that you connect external devices directly to the processor unit, to avoid signal  
delay.  
Install the following power supply kit (option) in the processor unit to enable use of the  
CS-120A.  
Name: Power Supply Kit Type: FSV-2403 Code No.: 000-067-013  
Name  
Power supply pcb  
Spacer  
Protection sheet  
Screw  
Type  
LEA50F-24-XFND  
SQ-22  
10-071-3508  
M3×8 C2700W  
NJC-203-PM  
Code No.  
000-143-913  
Qty  
1
Remarks  
000-159-305-10  
100-290-712  
4
1
000-163-190-10  
000-160-184-10  
4
1
Connector (NJC)  
1. Unfasten seven screws to remove the front cover of the processor unit.  
Screw  
M4x8, 7 pcs.  
F
UR  
U
N
O
WARNING  
Details  
omitted  
Processor unit, front view  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Remove two upset screws, detach the plugs J503, J502, J501, J504, J506 and J507,  
and then pull out the power module.  
Protection sheet  
VH4P  
Spacer  
Detach J503, J502,  
J501, J504 and  
J506.  
IF  
E
S
S
C
A
N
S
C
A
N
2
D
U
Power supply  
pcb  
A
L
D
C
O
N
VH5P  
Power Module  
Upset screws  
M5x25 SUS 2 pcs.  
Pin  
Hole  
Detach J507.  
Processor unit, front view  
3. Fix the power supply pcb (supplied) to the power module with spacers (supplied).  
4. Connect two VH connectors (provided on the power module) to the power supply pcb.  
5. Set the protection sheet (supplied) to the power supply pcb and fasten it with four  
screws.  
6. Reattach the power module.  
7. Connect between the processor unit and CS-120A as follows.  
Processor Unit  
POWER FOR CS-120A port  
NJC-203-PM  
YEL BRN  
CS-120A  
J201  
+24V_H  
+24V_C  
GND  
1
2
3
24V  
0V  
GND  
L
E
PP  
ORG BRN  
PPL BRN  
CIF1 or NMEA2/CIF2  
port  
CIF_TXD_H  
CIF_TXD_C  
CIF_RXD_H  
CIF_RXD_C  
SHIELD  
1
2
3
4
TD-H  
TD-C  
NN  
MM  
JJ  
KK  
BB  
EE  
DD  
Z
RD-H  
RD-C  
GND  
DSR-C  
DSR-H  
DTR-H  
10  
37-core cable  
10S1258  
Wiring between processor unit and CS-120A  
Note: An echosounder should be connected to the processor unit directly.  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Set the DIP switch on the DCON Board as follows.  
Input port  
CIF1  
DIP switch setting on DCON Board  
S3-#2: ON  
NMEA 2/CIF 2  
S3-#3: ON  
S3  
DCON Board (10P6984 or 10P6984A)  
Note: If the CIF1 format is selected, change baud rate to 2400 bps. See CIF BAUD RATE  
on page 3-9 for details.  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(This page intentionally left blank.)  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-4  
Y. Hatai  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-5  
Y. Hatai  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-6  
T akahashi T  
.
Y. Hatai  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-7  
T akahashi T  
.
Y. Hatai  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-8  
Y. Hatai  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This page is intentionally left blank.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-1  
1
2
3
4
5
6
制御部  
PROCESSOR UNIT  
送受信装置 FSV-301  
TRANSCEIVER UNIT  
FSV-3002/3002S  
操作部 FSV-3001  
CONTROL UNIT  
10S2145,23m(*2)  
10S2144,13m(*2)  
10S2078,8m,φ17 *3  
ミドリ GRN  
*4  
CN-A103(108)  
J411(421)  
CN-C101  
*3 *5  
10S2076,10m(5m)  
*1  
TPYCY-4  
CN-A101  
TRXRXD-H  
TRXRXD-C  
TRXTXD-H  
TRXTXD-C  
SIG_D0-H  
SIG_D0-C  
DEMGUP-H  
DEMGUP-C  
SIG_D1-H  
SIG_D1-C  
SIG_D2-H  
SIG_D2-C  
SIG_D3-H  
SIG_D3-C  
SIG_D4-H  
SIG_D4-C  
SIG_D5-H  
SIG_D5-C  
DUPLSW-H  
DUPLSW-C  
AUDIO-H  
AUDIO-C  
+12V  
CN-A201  
TB-C101  
CN-B102 CN-B101  
XH-15P  
J1  
J2  
J445  
A
B
C
D
E
F
H
LL  
J
K
L
M
N
P
R
S
T
10S1258,φ18,MAX.100m  
アカ 11 RED  
チャ 11 BRN  
J1  
J1  
A
220VAC  
3φ,50/60Hz  
1
U
V
W
A
A
B
C
D
E
F
H
LL  
J
K
L
M
N
P
R
S
T
U
A
3
4
1
2
5
6
7
8
9
MSRXD-H  
MSRXD-C  
MSTXD-H  
MSTXD-C  
UPLSW-H  
UPLSW-C  
DEMGUP-H  
DEMGUP-C  
MDLSW-H  
MDLSW-C  
DNLSW-H  
DNLSW-C  
DNCMD-H  
DNCMD-C  
UPCMD-H  
UPCMD-C  
DUPLSW-H  
DUPLSW-C  
TSFLG-H  
TSFLG-C  
MSROLL  
CN1RXD-H  
CN1RXD-C  
CN1TXD-H  
CN1TXD-C  
CN1TXA-H  
CN1TXA-C  
CN1TXB-H  
CN1TXB-C  
CN1TYA-H  
CN1TYA-C  
CN1TYB-H  
CN1TYB-C  
GND  
4 YEL  
CN1RXD-H  
CN1RXD-C  
CN1TXD-H  
CN1TXD-C  
CN1TXA-H  
CN1TXA-C  
CN1TXB-H  
CN1TXB-C  
CN1TYA-H  
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
2
3
4
5
6
7
8
アカ  
アオ  
クロ  
RED  
BLU  
BLK  
B
C
D
E
F
H
LL  
J
K
N
P
R
S
T
U
V
X
W
Y
Z
B
C
D
E
F
J
K
L
M
N
P
JJ  
KK  
LL  
クロ 4 BLK  
ミドリ 3 GRN  
クロ 3 BLK  
アオ 5 BLU  
クロ 5 BLK  
クロ 10 BLK  
シロ 10 WHT  
P
A
B
C
D
ムラサキ PPL  
ダイ 12 ORG  
チャ 12 BRN  
P
シロ  
チャ  
クロ  
チャ  
シロ  
アオ  
シロ  
WHT  
BRN  
BLK  
BRN  
WHT  
BLU  
WHT  
YEL  
BLK  
WHT  
BLK  
アカ 19 RED  
ダイ 19 ORG  
チャ  
6 BRN  
P
TT  
クロ 6 BLK  
ムラサキ 7 PPL  
クロ 7 BLK  
アカ 8 RED  
シロ  
ミドリ 14 GRN  
アカ 14 RED  
クロ 9 BLK  
ハイ 9 GRY  
P
10 CN1TYA-C  
11 CN1TYB-H  
12 CN1TYB-C  
13 GND  
14 GND  
15 GND  
FSV-2431  
*1  
IV-8sq.  
13 YEL  
P
P
P
P
P
P
P
チャ 13 BRN  
クロ 8 BLK  
ムラサキ 8 PPL  
ダイ 4 ORG  
クロ 4 BLK  
クロ 3 BLK  
アカ 3 RED  
8 WHT  
上下装置  
HULL UNIT  
FSV-303/304  
クロ  
シロ  
クロ  
GND  
GND  
XH-14P  
CN-A202  
J2  
R
S
T
U
V
X
Z
W
Y
1
2
3
4
5
6
7
8
9
ムラサキ PPL  
CN1PON-H  
CN1PON-C  
CN1POF-H  
CN1POF-C  
CN1AUDV1  
CN1AUDV2  
CV1AUDV3  
CN1BRLV1  
CN1BRLV2  
CN1BRLV3  
+12V  
シロ 1 WHT  
クロ 1 BLK  
アカ 2 RED  
クロ 2 BLK  
シロ 9 WHT  
ミドリ 9 GRN  
CN1PON-H  
CN1PON-C  
CN1POF-H  
CN1POF-C  
CN1AUDV1  
CN1AUDV2  
CN1AUDV3  
CN1BRLV1  
CN1BRLV2  
P
P
P
P
P
P
P
クロ  
アカ  
シロ  
BLK  
RED  
WHT  
U
V
X
W
Y
Z
AA  
V
X
W
5 YEL  
クロ 5 BLK  
チャ 2 BRN  
クロ 2 BLK  
ミドリ 6 GRN  
クロ 6 BLK  
シールド SHIELD  
ミドリ GRN  
クロ  
アカ  
クロ  
BLK  
RED  
BLK  
AA MSR_GND  
Y
BB  
CC  
Z
MSPITCH  
MSP_GND  
10 YEL  
AA  
BB  
CC  
DD  
EE  
FF  
HH  
JJ  
KK  
MM  
NN  
PP  
RR  
SS  
TT  
GND  
シロ 10 WHT  
シロ 11 WHT  
アオ 11 BLU  
ムラサキ 13 PPL  
シロ 13 WHT  
チャ 12 BRN  
シロ 12 WHT  
ミドリ GRN  
JJ PWRHUL-H  
NN PWRHUL-C  
PP  
BB EXTKP-C  
CC EXTKP-H  
CC  
PP  
MM  
10 CN1BRLV3  
11  
シロ  
シロ  
WHT  
YEL  
WHT  
シンセン  
CORE  
DD  
PWRHUL-H  
ミドリ 14 GRN  
チャ 14 BRN  
クロ 7 BLK  
アオ 7 BLU  
アオ 15 BLU  
チャ 15 BRN  
チャ 18 BRN  
シロ 18 WHT  
ムラサキ 16 PPL  
チャ 16 BRN  
チャ 17 BRN  
ハイ 17 GRY  
SIG_D6-H  
+12V  
P
P
P
P
P
P
TT PWRHUL-C  
EE SIG_D6-C  
FF SIG_D7-H  
HH SIG_D7-C  
GND  
+12V RR  
GND NN  
NC  
NC TT  
13 GND  
12 +12V  
14 GND  
TRX 10P6960 x10  
*3  
10S2223,φ16  
JJ  
SS  
KP-H  
B201  
P1~P2  
KK KP-C  
MM FS-H  
NN FS-C  
B202  
P1~P2  
接続箱  
PP  
ENB-H  
B203  
P1~P2  
JUNCTION BOX  
FSV-305 *2  
J1-20 J1-20  
RR EMB-C  
SS FSCLK-H  
B204  
P1~P2  
TT  
FECLK-C  
B201 B101  
*4  
CN-A104(109)  
J412(422)  
B205  
P1~P2  
B220 B120  
*1  
MONITOR CABLE  
KEC-15P  
外部モニター  
EXT. MONITOR  
DS1V-R  
GND  
DS1V-G  
GND  
DS1V-B  
GND  
1
B206  
P1~P2  
*1  
アース銅板 *1  
COPPER STRAP  
6
2
7
3
8
送受波器  
B207  
P1~P2  
TRANSDUCER  
延長キット *2  
EXTENSION KIT  
B208  
P1~P2  
DS1VSY 14  
GND  
DS1HSY 13  
10  
B209  
P1~P2  
5
B210  
P1~P2  
GND  
POWER  
*1  
DPYCYS-2.5  
TB-B101  
1 AC_IN-H  
2 AC_IN-C  
100/110/115/  
220/230 VAC  
1φ,50/60Hz  
アース銅板  
COPPER STRAP  
WEA-1004  
W=50,1.2m  
CN-A110  
J16  
AC_IN-H  
AC_IN-C  
SHIELD  
*1  
DPYCY-1.5  
NCS-253-P  
3
2
1
*1  
IV-8sq.  
DRAWN  
TITLE  
名称  
注記  
FSV-30/30S  
T.YAMASAKI  
T.TAKENO  
9/Jul/08  
9/Jul/08  
NOTE  
*1)造船所手配  
CHECKED  
*1: SHIPYARD SUPPLY.  
*2: OPTION.  
カラースキャニングソナー  
相互結線図  
*2)オプション。  
APPROVED 18/Jul/08 R.Esumi  
SCALE  
*3)コネクタは工場にて取付済み。  
*4)( ):副表示部/副操作部用。  
*5)和文仕様では5/10mより選択。  
*3: CONNECTOR PLUGS FITTED AT FACTORY.  
*4: ( ): FOR SUB-MONITOR OR SUB-CONTROL.  
*5: 5m CABLE AVAILABLE FOR JAPANESE ONLY.  
MASS  
NAME  
COLOR SCANNING SONAR  
INTERCONNECTION DIAGRAM  
FURUNO ELECTRIC CO., LTD.  
kg  
DWG No.  
10-080-0101-0  
C1323-C02- D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-2  
1
2
3
PCS-E68PM  
J14 PC IF  
MONITOR J1  
MD-R  
GND  
KEC-15P  
データ収録装置  
DATA RECORDER  
外部モニター  
EXTERNAL MONITOR  
1
1
6
2
7
3
8
制御部  
メンテナンス専用  
FOR MAINTENANCE  
MD-G  
GND  
MD-B  
GND  
PROCESSOR UNIT  
FSV-2402/2402S  
FSV-3002/3002S  
FSV-8402  
68  
*4  
MD-V-SYNC 14  
GND  
MD-H-SYNC  
A
B
C
D
*2  
02S8040,6m  
SRCN6A16-10P  
5
13  
ES2/NET  
J12  
ES2-SIG-IN  
GND  
KP-DN-IN  
NC  
ES2-WL-IN  
GND  
GND  
KP-UP-IN  
NC  
魚探 I/F  
ES I/F  
VI-1100A  
1
2
3
4
5
6
7
8
9
GND 10  
*4  
*3  
MJ-A6SPF  
*2  
MJ-A6SPF0011/0012 航法装置  
5/10m,φ6  
NMEA1  
NMEA1-TXD-H  
J3  
1
2
3
4
6
NAVIGATOR  
NMEA1-TXD-C  
NMEA1-RXD-H  
NMEA1-RXD-C  
SHIELD  
*4  
10 GND  
*3  
MJ-A6SPF  
*4  
*2  
SRCN6A21-10S  
*2  
MJ-A6SPF0011/0012 航法装置  
NMEA2/CIF2  
J4  
*2  
外部KP CO-0.2x5P  
EXTERNAL KP  
*5  
1
2
3
4
6
NMEA2-TXD-H  
NMEA2-TXD-C  
NMEA2-RXD-H  
NMEA2-RXD-C  
SHIELD  
EXT-KP  
J13  
INTKP1  
GND  
INTKP2  
GND  
INTKP3  
GND  
GND  
EXT-KP-IN-H  
EXT-KP-IN-C  
5/10m,φ6  
NAVIGATOR  
1
2
3
4
5
6
7
8
9
*4  
*2  
CO-0.2x2P  
SRCN6A13-5P  
P
CIF1  
J5  
1
2
3
4
5
CIF-TXD-H  
CIF-TXD-C  
CIF-RXD-H  
CIF-RXD-C  
SHIELD  
潮流計  
CURRENT INDICATOR  
P
10 EXT-12VKP-IN  
*4  
*4  
CN-A105  
J15  
1
2
3
4
5
6
7
8
AUX  
J6  
NC  
17JE-13260-02(D1)  
パソコン  
PC  
メンテナンス専用  
FOR MAINTENANCE  
1
2
3
7
AUX-TXD  
AUX-RXD  
GND  
NC 25  
*4  
*2  
SRCN6A16-10P  
*2  
GYRO  
J7  
外部スピーカ  
EXTERNAL SPEAKER  
SEM-21Q  
CO-0.2x2P ADコンバータ  
AD CONVERTER  
AD-100  
CN-A106  
AD-DATA-H  
AD-DATA-C  
AD-CLK-H  
AD-CLK-C  
2
3
6
7
P
2.8m  
1
2
SP-AUDIO  
GND  
P
NJC-203PM  
SHIELD 10  
J17 CS-120A  
+24VDC  
0V  
*4  
*2  
SRCN6A13-3P  
CS-120A  
1
2
3
*1  
DPYC-1.5  
LOG  
LOG  
GND  
NC  
J8  
スピードログ  
SPEED LOG  
SHIELD  
1
2
3
FNZ-AUX  
J11  
*4  
*2  
SRCN6A16-7P  
SRCN2A21-16S  
1
2
3
4
5
6
7
8
9
SONDE_3  
GND  
SONDE_4  
GND  
SONDE_5  
GND  
SONDE_6  
GND  
SONDE_7  
予備  
RESERVE  
*2  
02S8040,6m 魚探I/F  
ES1  
ES1-SIG-IN  
GND  
ES1-KP-IN  
NC  
ES1-WL-IN  
SHIELD  
GND  
J9  
1
2
3
4
5
6
7
ES I/F  
VI-1100A  
注記  
*1)造船所手配  
*2)オプション。  
*3)コネクタは工場にて取付済み。  
*4  
*2  
SRCN6A21-10P  
10 GND  
11  
*4)コネクタクランプでアースに落とす。  
*5)IFES基板S2 #8にて選択。  
工場出荷時はCIF(OFF)。  
*1  
CO-0.2x5P ネットゾンデ  
NET SONDE  
SONDE_8  
FNZ  
J10  
SONDE_0  
GND  
SONDE_1  
GND  
SONDE_2  
GND  
SONDE_KP  
GND  
SONDE_WL  
12 GND  
13 SONDE_9  
14 GND  
1
2
3
4
5
6
7
8
9
16  
GND  
NOTE  
*1: SHIPYARD SUPPLY.  
*2: OPTION.  
*3: CONNECTOR PLAG FITTED AT FACTORY.  
*4: GROUND THRU CONNECTOR CLAMP.  
*5: SELECT CIF OR NMEA AT S2 #8 ON  
IFES BOARD. DEFAULT IS CIF (OFF).  
GND 10  
*4  
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5  
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5  
DRAWN  
Dec. 26 '06  
CHECKED  
TITLE  
FSV-2402/2402S/3002/3002S/8402  
制御部外部信号接続  
E.MIYOSI  
名称  
NAME  
TAKAHASHI. T  
Y. Hatai  
MASS  
kg  
APPROVED  
SCALE  
相互結線図  
FSV-24/24S/30/30S/84/84L  
PROCESSOR UNIT EXTERNAL INTERFACE  
INTERCONNECTION DIAGRAM  
DWG.No.  
C1318-C03- N  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EdgeStar Refrigerator Upright Refrigerator User Manual
Euro Pro Vacuum Cleaner NV31 User Manual
Euro Pro Vacuum Cleaner V2022 User Manual
Excalibur electronic Games 461 User Manual
FEIN Power Tools Drill ASze 648a User Manual
Fisher Price Plumbing Product W4119 User Manual
Frigidaire Air Conditioner FRA09EPT1 User Manual
Frigidaire Dishwasher FGBD2451K User Manual
Fujitsu Scanner S1500 User Manual
GMC Automobile X2111 User Manual