Installation Manual
RADAR SENSOR
DRS2D/DRS4D/
DRS4A/DRS6A/DRS12A/DRS25A
SAFETY INSTRUCTIONS ............................................................................i
SYSTEM CONFIGURATION .......................................................................ii
EQUIPMENT LISTS....................................................................................iv
1. MOUNTING............................................................................................1
1.1 Mounting Considerations..............................................................................................1
1.2 Mounting Procedure for DRS2D/4D .............................................................................2
1.3 Mounting Procedure for DRS4A/6A/12A/25A...............................................................3
1.4 Mounting of Power Supply Unit PSU-013 (for DRS25A)/PSU-012 (Option) ................8
2. WIRING..................................................................................................9
2.1 Wiring inside DRS2D/4D ............................................................................................12
2.2 Wiring inside DRS4A/6A/12A/25A..............................................................................16
2.3 Wiring inside Power Supply Unit PSU-013 (for DRS25A) ..........................................20
2.4 Wiring inside Power Supply Unit PSU-012 (Option)...................................................21
PACKING LISTS...................................................................................... A-1
OUTLINE DRAWINGS............................................................................. D-1
INTERCONNECTION DIAGRAMS.......................................................... S-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM CONFIGURATION
DRS2D/4D/4A/6A/12A
RADAR SENSOR
DRS2D/DRS4D
RADAR SENSOR
DRS4A/DRS6A/DRS12A
NMEA 2000
Equipment
NMEA 2000
Equipment
Power Supply Unit
PSU-012*
12-24 VDC
OR
Multi Function Display BlackBox
MFDBB
Multi Function Display
MFD8/12
: Standard Supply
: Optional Supply
: Local Supply
RECTIFIER
RU-1746B
12-24 VDC
100/110/220/230 VAC
*The power supply unit PSU-012 is necessary in the combination of radar sensor and MFD.
DRS2D/4D
NO
DRS4A
YES
NO
DRS6A
YES
NO
DRS12A (future development)
MFD8
YES
YES
NO
NO
MFD12
MFDBB
NO
NO
NO
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
DRS25A
RADAR SENSOR
DRS25A
NMEA 2000
Equipment
Power Supply Unit
PSU-013
12-24 VDC
Multi Function
Display BlackBox
MFDBB
OR
Multi Function Display
MFD8/12
RECTIFIER
RU-1746B
: Standard Supply
: Optional Supply
: Local Supply
12-24 VDC
100/110/220/230 VAC
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
EQUIPMENT LISTS
Standard supply
Name
Type
Code No.
Qty
1
Remarks
Radar Sensor XN10A-RSB-118-092
XN12A-RSB-118-093
-
For DRS4A, w/CP03-32601
For DRS6A, w/CP03-32601
1
XN12A-RSB-118-094
-
1
For DRS12A, 1255 mm,
w/CP03-32601
XN13A-RSB-118-094
XN12A-RSB-118-095
XN13A-RSB-118-095
DRS2D
1
1
1
1
1
1
For DRS12A, 1795 mm,
w/CP03-32601
-
-
-
-
-
For DRS25A, 1255 mm, w/CP03-
32601
For DRS25A, 1795 mm, w/CP03-
32601
Radome, 2 kW,
w/CP03-32101
DRS4D
Radome, 4 kW,
w/CP03-32101
Power Supply PSU-013
Unit
For DRS25A, w/SP03-16101 and
CP03-32700
Installation
Materials
CP03-32101
CP03-32601
CP03-32200
001-025-270 1 set For DRS2D/4D
001-025-780 1 set For DRS4A/6A/12A/25A
000-011-720
000-011-721
000-011-722
000-011-723
000-011-990
000-011-991
000-011-992
000-011-993
1
Two-way cable, MOD-ASW0001-
100+, 10 m, for DRS2D/4D/4A/6A/12A
CP03-32300
CP03-32400
CP03-32500
CP03-32800
CP03-32810
CP03-32820
CP03-32830
Two-way cable, MOD-ASW0001-
150+, 15 m, for DRS2D/4D/4A/6A/12A
Two-way cable, MOD-ASW0001-
200+, 20 m, for DRS2D/4D/4A/6A/12A
Two-way cable, MOD-ASW0001-
300+, 30 m, for DRS2D/4D/4A/6A/12A
Two-way cable, MOD-ASW0002-
100+, 10 m, for DRS25A
Two-way cable, MOD-ASW0002-
150+, 15 m, for DRS25A
Two-way cable, MOD-ASW0002-
200+, 20 m, for DRS25A
Two-way cable, MOD-ASW0002-
300+, 30 m, for DRS25A
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
Optional supply
Name
Type
Code No.
Qty
Remarks
Power Supply PSU-012
Unit
-
1 set
Gasket
OP03-203
OP03-205
OP03-206
001-025-290
001-025-790
1
For DRS2D/4D, φ10 NMEA2000
cable
For DRS4A/6A, φ10 NMEA2000
cable
001-035-290
For DRS25A, φ10 NMEA2000 cable
For NMEA2000 connection with a unit
For LAN cable extension
2 m
Resister Assy OP03-204
001-025-300
1
1
1
1
1
1
1
1
1
1
1
Joint Box
TL-CAT-012
000-167-140-10
000-167-175-10
000-167-176-10
000-167-177-10
LAN Cable
MOD-Z072-020+
MOD-Z072-050+
MOD-Z072-100+
5 m
10 m
Cable Assy
M12-05BFFM-010 000-167-965-10
M12-05BFFM-020 000-167-966-10
M12-05BFFM-060 000-167-967-10
NMEA2000, φ6, w/connector, 1 m
NMEA2000, φ6, w/connector, 2 m
NMEA2000, φ6, w/connector, 6 m
NMEA2000, φ10, w/connector, 1 m
NMEA2000, φ10, w/connector, 2 m
NMEA2000, φ10, w/connector, 6 m
CB-05BFFM-010
CB-05BFFM-020
CB-05BFFM-060
000-167-971-10
000-167-972-10
000-167-973-10
v
Download from Www.Somanuals.com. All Manuals Search And Download.
1. MOUNTING
1.1 Mounting Considerations
• The radar sensor is generally installed either on top of the wheelhouse or on the radar mast on
a suitable platform. Locate the radar sensor where there is a good all-round view. Any obstruc-
tion will cause shadow and blind sectors. A mast for instance, with a diameter considerably less
than the horizontal beamwidth of the radiator, will cause only a small blind sector, but a horizon-
tal spreader or crosstrees in the same horizontal plane as the radar sensor would be a much
more serious obstruction; you would need to place the radar sensor well above or below it.
• It is rarely possible to place the radar sensor where a completely clear view in all directions is
available. Thus, you should determine the angular width and relative bearing of any shadow
sectors for their influence on the radar at the first opportunity after fitting.
• A magnetic compass will be affected if the radar sensor is placed too close to it. Observe the
compass safe distances mentioned in the SAFETY INSTRUCTIONS to prevent interference to
a magnetic compass.
• Do not paint the radiator aperture and radome to ensure proper emision of the radar waves.
• When this radar sensor is to be installed on large vessels, consider the following points:
• The two-way cable run between the radar sensor and MFDBB, MFD8, MFD12 or PSU-012
comes in lengths of 10 m, 15 m, 20 m or 30 m.
• Deposits and fumes from a funnel or other exhaust vent can adversely affect the aerial per-
formance and hot gases may distort the radiator portion. The radar sensor must not be
mounted where the temperature is more than 55 degrees centigrade.
As shown in the figure below, the radar sensor may be installed on a common mast or on the radar
mast.
(a) Common mast
(b) Radar mast
For DRS4A/6A/12A
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Radar sensor
Radar sensor
Radar sensor
Radar sensor
For DRS2D/4D
1.2 Mounting Procedure for DRS2D/4D
1. Remove mounting hardware at the bottom of the radar sensor, four each of hex bolts
(M10x20), spring washers and flat washers. Save the spring washers and flat washers to use
them to fix the radome base to the platform, at step 3. If the thickness of the mounting platform
is 5 mm or less, also save the bolts.
Screws
(two screws on other side)
Stern
Cable entry
Flat washer
Bow
Spring washer
Hex bolt (M10 x 20)
2. Construct a platform (steel or aluminum) 6-10 mm in thickness referring to the outline drawing
at the back of this manual. Fasten the platform to the mounting location. Next, position the
base so the cable entrance is facing the stern.
Note: When drilling holes in the platform, be sure they are parallel with the fore and aft line.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Use the hex bolts*, flat washers and spring washers removed at step 1, and fasten the
radome base to the platform. The torque should be between 19.6-24.5Nzm.
*If the thickness of the platform is 6-10 mm, use M10x25 bolts (supplied). For thicker platform, use
locally supplied bolts.
Transceiver
module
Antenna base
assy.
5 mm or under: M10x20 (local supply)
L
6-10 mm:
M10x25 (supplied)
over 10 mm:
locally supplied bolts
As for length, use the bolt
the "L" shown in the figure
in left becomes 10 to 15 mm.
Flat
washer
Platform
Spring
washer
Hex bolt
Apply silicone sealant.
(M10 x 25
or M10 x 20)
4. Mount the cover tentatively. The cover is opened for wiring at Chapter 2.
1.3 Mounting Procedure for DRS4A/6A/12A/25A
Refer to the outline drawing at the back of this manual, and drill five holes in the mounting platform:
four holes of 15 mm in diameter for fixing the radar sensor and one hole of 25-30 mm in diameter
for the signal cable. The outline drawing shows two cable entrance holes, one on the radar sensor
and one on the rubber mat. Use only the one on the rubber mat.
1.3.1 Fastening the radiator to the radiator bracket
1. Remove the radiator cap from the radiator bracket.
2. Coat the surface of the radiator bracket with silicone sealant as shown in the figure below.
RADIATOR BRACKET
(top view)
10mm
(Do not coat.)
Coat hatched area with
silicone sealant.
3. Coat threaded holes on the antenna radiator with silicone sealant.
4. Grease the O-ring and set it to the radiator bracket.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Coat the hex bolts (4 pcs.) with silicone sealant. Fasten the antenna radiator to the radiator
bracket with the hex bolts, flat washers and spring washers supplied with the radiator.
Antenna
radiator
Coat threaded
holes with silicone
sealant.
O-ring
Radiator bracket
Flat washer
Spring washer
Hex bolt
(M8 x 30)
Coat bolts with
silicone sealant.
1.3.2 Mounting the radar sensor
The radar sensor can be mounted using the fixing holes on the outside (200 x 200 mm) or inside
(140 x 150 mm) the radar sensor.
Using outside fixing holes of radar sensor
Use the hex bolts (supplied) to mount the radar sensor as below.
1. Lay the corrosion-proof rubber mat (supplied) on the mounting platform.
Rubber mat
Ground terminal
Bow mark
4
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Lay the radar sensor on the mounting platform, orienting it as shown below. (The hinges must
face toward the stern.)
BOW
STERN
Hinge
CAUTION
Do not lift the radar sensor by the
radiator; lift it by the housing.
The radiator may be damaged.
3. Insert four hex bolts (M12 x 60, supplied) and seal washers (φ30, supplied) from the top of the
housing, as shown below.
Hex. bolt
Seal washer
(Face projecting part down.)
Flat washer
Spring washer
Nut
5
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Pass flat washers (M12, supplied), spring washers (M12, supplied) and nuts (M12, supplied)
onto hex. bolts. Fasten by tightening nuts. Do not fasten by tightening the hex. bolts; seal
washers may be damaged.
Seal washer
Antenna
unit
Rubber mat
Mounting
platform
Silicone
sealant
Flat washer
5. Coat flat washers, spring washers, nuts and exposed parts of bolts with anticorrosive sealant.
6. Prepare ground point in mounting platform (within 300 mm of ground terminal on radar sen-
sor) using M6 x 25 bolt, nut and flat washer (supplied).
7. Run the ground wire (RW-4747, 340 mm, supplied) between the ground terminal and ground
point.
8. Coat ground terminal and ground point with silicone sealant as shown below.
Hex. bolt
Flat washer
Ground
Flat washer
wire
Spring washer
Hex. nut
Silicone
OR
GROUND
POINT
sealant
Hex. nut
Ground
wire
Spring washer
Flat washer
Hex. nut
Weld here.
GROUND
TERMINAL
Silicone
sealant
Ground
wire
antenna
unit
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Using inside fixing holes of the sensor housing
If this radar is replacing a FURUNO radar whose mounting dimensions are the same as this one
(140 x 150 mm), it may be possible to use its mounting platform. This method requires removal of
the RF unit from the radar sensor to access inside fixing holes. Use hex bolts, flat washers, spring
washers and nuts (local supply) to mount the radar sensor.
1. Unfasten four bolts from the cover to open the radar sensor.
2. Unplug the PCS connector from RF unit.
3. Separate upper chassis from lower chassis by removing two bolts (M8x25).
4. Remove RF unit by unfastening two hex bolts and two fixing bolt.
Upper chassis
Bolt
M8x25,
2 pcs.
RF unit
PCS connector
Hex bolt
2 pcs.
Fixing bolt
(2 pcs.)
Inside fixing holes
Lower chassis
(Example: DRS4A/6A)
For DRS12A/25A, unfasten four hex bolts, not two fixing bolts, to remove the RF unit.
5. Lay the corrosion-proof rubber mat (supplied) on the mounting platform.
6. Fasten the lower chassis to the mounting platform with hex bolts, spring washers, flat washers
and nuts (local supply), and then coat flat washers, nuts and exposed parts of bolts with sili-
cone sealant. Cut a slit in the rubber bushing and insert bolt into the bushing. Do not use seal
washers.
7. Remount RF unit.
8. Coat outside fixing holes with silicone sealant and then attach caps (supplied) to holes.
9. Do steps 6-8 on page 6.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
1.4 Mounting of Power Supply Unit
PSU-013 (for DRS25A)/PSU-012 (Option)
For combinations shown below, the optional power supply unit PSU-012 (Code No.: 000-011-756)
is necessary. The PSU-013 is required for any DRS25A installation.
DRS2D/4D
NO
DRS4A
YES
NO
DRS6A
YES
NO
DRS12A
MFD8
YES
YES
NO
NO
MFD12
MFDBB
NO
NO
NO
Contents of PSU-0012/013
Type Code No.
Name
Qty
Remarks
Power supply unit
PSU-012
PSU-013
-
1
-
for DRS25A
5 m
Cable assy
LAN cable
VL3P-VV-S2X2C-AA050
MOD-Z072-050+
000-152-217-10
000-167-176-10
000-158-850-10
000-155-839-10
000-157-874-10
1
1
4
2
2
5 m, standard
Self-tapping screw 4x20, SUS304
Fuse*
FGB0 250V 10A
FGB0 250V 15A
For 24 VDC
For 12 VDC
*Note: The power supply unit is shipped with 15A fuse. Replace fuse with 10A when using the unit
with 24V ship’s battery.
The power supply unit can be installed almost anywhere provided the following conditions are met:
• Location is dry, well ventilated.
• Sufficient maintenance space is available.
• Installated within 2, 5 or 10 m (2 and 10 m: optional supply) from the multi function display.
Do not install the power supply unit on the overhead; install it on the deck or bulkhead. Use four
tapping screws (4x20, supplied) to fasten the power supply unit.
Self-tapping screw
(4x20, 4 pcs.)
Power supply unit PSU-012/013
8
Download from Www.Somanuals.com. All Manuals Search And Download.
2. WIRING
The MFDBB, MFD8, MFD12 or PSU-012 connects to the radar sensor with the two-way cable
MOD-ASW0001 (MOD-ASW0002 for DRS25A).In order to minimize the chance of picking up
electrical interference, avoid where possible routing the two-way cable near other onboard elec-
trical equipment. After passing the cable through the hole in the radar sensor, apply sealing com-
pound around the hole for waterproofing. When connecting to other NMEA2000 equipment, use
the optional cable M12-05BFFM (φ6) or CB-05BFFM (φ10).
NOTICE
Before connecting or disconnecting the
NMEA2000 cable, turn off the radar sensor.
The sensor may become damaged if the power is
not turned off.
Wiring for DRS2D/4D/4A/6A/12A without PSU-012
RADAR SENSOR
DRS2D/DRS4D
RADAR SENSOR
DRS4A/DRS6A/DRS12A
NMEA2000 cable
M12-05BFFM (φ6) or
CB-05BFFM (φ10)
Two-way cable
MOD-ASW0001
(10/15/20/30 m)
NMEA2000
Equipment
NMEA2000
Equipment
NMEA2000 cable
M12-05BFFM (φ6) or
CB-05BFFM (φ10)
: Standard Supply
: Optional Supply
To Multi Function Display BlackBox
MFDBB or Multi Function Display
MFD8/12
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring for DRS2D/4D/4A/6A/12A with PSU-012
Radar Sensor
DRS2D/DRS4D
Radar Sensor
DRS4A/DRS6A/DRS12A
NMEA2000 cable
M12-05BFFM (φ6) or
CB-05BFFM (φ10)
Two-way cable
MOD-ASW0001
(10/15/20/30 m)
NMEA2000
Equipment
NMEA2000
Equipment
NMEA2000 cable
M12-05BFFM (φ6) or
CB-05BFFM (φ10)
(LAN)
(Power)
Power Supply Unit
PSU-012
12-24 VDC
Power cable
VL3P-VV-S2X2C-AA050
(supplied with PSU-012)
: Standard Supply
LAN cable
: Optional Supply
: Local Supply
MOD-Z072
-5 m: supplied
-2, 10 m: option
To ship's ground
Ground wire
(Local supply, IV-2sq)
To Multi Function Display BlackBox
MFDBB or Multi Function Display
MFD8/12
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring for DRS25A
RADAR SENSOR
DRS25A
NMEA2000 cable
M12-05BFFM (φ6) or
CB-05BFFM (φ10)
NMEA2000
Equipment
Two-way cable
MOD-ASW0002 cable
(10/15/20/30 m)
(POWER)
(LAN)
Power cable
VL3P-VV-S2X2C-AA50
Power Supply Unit
PSU-013
LAN cable
MOD-2072-050
12-24 VDC
Ground wire
(Local supply, IV-2sq)
To Multi Function Display BlackBox
MFDBB or Multi Function Display
MFD8/12
To ship’s ground
: Standard Supply
: Optional Supply
: Local Supply
11
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1 Wiring inside DRS2D/4D
Two-way cable connection
1. Unfasten three screws at the bottom of the mounting base to remove the fixing plate for the
gasket.
Fixing plate
(for gasket)
2. Remove the gasket, and pass the two-way cable MOD-ASW0001.
3. Fasten the shield of the cable (power) with the cable clamp in the radar sensor, and connect
the connector of cable (power) to the power terminal.
4. Connect the RJ-45 connector of the cable (LAN) to the LAN terminal in the radar sensor.
LAN terminal
Power terminal
Fix the cable (LAN)
with this locking saddle.
Fix the shield cable
(power) with this clamp.
5. Push cables of the two-way cable into the slits of the gasket inside the radar sensor.
Note: The ends of the gasket are different. Larger end should be up.
Large
Up
Small
12
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF
chassis.
This height should
be lower than the RF
unit when installed to
the bottom of the sensor.
Cable
Gasket
RF unit
Gasket
Note: If the two-way cable touches the platform near the mounting base, wind vinyl tape around
the cable at the point where it is bent.
7. Confirm that the rubber gasket is properly positioned and that the triangle mark on the cover is
aligned with the triangle mark on the mounting base, then tighten the fixing screws for the
cover.
Triangle marks
Cover
Mounting
base
Connecting to NMEA2000 equipment
To connect NMEA2000 equipment to the sensor, wire an optional NMEA2000 cable, M12-05BFFM
(φ6) or CB-05BFFM (φ10), as shown below. Also, the gasket at the bottom of mounting base must
be replaced.
1. Do steps 1 to 4 on page 12.
2. Refer to the figure below, and fabricate the cable M12-05BFFM (φ6) or CB-05BFFM (φ10).
5
15 (Area fastened with the cable clamp)
M12-05BFFM cable
Shield
100
Fabrication of cable M12-05BFFM (φ6)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
5
15
Shield
CB-05BFFM cable
370
Fasten the cable tie (supplied) within
15 mm from the end of vinyl sheath.
Wind vinyl tape.
(supplied)
CB-05BFFM cable
65
20
15 (Area fastened with the cable clamp)
Fabrication of CB-05BFFM cable
3. Insert wires of cable M12-05BFFM (φ6) or CB-05BFFM (φ10) to the NMEA connector inside the
radar sensor, consulting the label on the connector for location. As for shield, use the cable
clamp shown below to fasten it to the RF chassis.
Cable
M12-05BFFM (φ6)
CB-05BFFM (φ10)
Use the clamp in the plastic bag supplied
inside the radar sensor.
Use the clamp supplied with the optional gasket
(Type: OP03-203, Code No.: 001-025-290)
Clamp
Zoom up
Attach the cable clamp
using this screw.
Cable clamp
(Face projecting part down.)
14
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Push LAN and POWER cables of the two-way cable and cable M12-05BFFM (φ6) or CB-
05BFFM (φ10) into the slits of the gasket inside the mounting base. Depending on the
NMEA2000 cable used, replace the gasket as shown below.
Cable type
Gasket
M12-05BFFM (φ6)
CB-05BFFM (φ10)
Use the gasket supplied in the plastic Use the optional gasket. (Type: OP03-203,
bag inside the radar sensor. Code No.: 001-025-290)
Note: The ends of the gasket are different. Larger end should be up)
Large
Up
Small
5. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF
chassis.
This height should
be lower than the RF
unit when attaching to
the bottom of the sensor.
Gasket
Cable
RF unit
RF unit
Gasket
Note: If the two-way cable touches the platform near the radar sensor base, wind vinyl tape
around the cable at the point where is bent.
6. Confirm that the rubber gasket is properly positioned and that the triangle mark on the cover is
aligned with the triangle mark on the mounting base, then tighten the fixing screws for the
cover.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2 Wiring inside DRS4A/6A/12A/25A
Two-way cable connection
If you have no NMEA2000 equipment to connect, use the MOD-ASW0001 cable (standard sup-
ply).
1. Open the radar sensor cover by loosening four bolts, and fix the stay for safety purpose.
2. Unfasten four bolts to detach the plate, gasket, washer and lid. Discard the lid at the bottom of
the hole for the gasket.
Plate
Gasket
Washer
Lid
Stay
3. Pass the two-way cable MOD-ASW0001 (MOD-ASW0002 for DRS25A) through the bottom of
the chassis and washer.
4. Fasten the shield of the power cable of the two-way cable (part of the foil) with the cable
clamp in the radar sensor, and then connect the power cable to the power terminal as shown
on next page.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Attach the LAN cable of the two-way cable to the LAN terminal in the radar sensor.
Fix the power cable at the foil part
with this cable clamp.
Power cable
White
Black
Power terminal
LAN cable
RF unit
LAN terminal
DRS4A/6A/12A
Fix the power cable at the copper
foil part with this cable clamp.
Gasket
LAN cable
White
Power terminal
Blue
Red
Black
Power cable
LAN terminal
DRS25A
6. Refer to the illustration shown below, and attach the gasket to the two-way cable, inserting the
cable into the slits on the gasket.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF
chassis.
This height should be lower than the
RF unit when installed to the bottom
of the sensor.
Cable
RF unit
Gasket
Gasket
Washers
8. Push the gasket and washers into the hole at the bottom of the radar sensor, then fasten four
pan head screws to fix the plate to the sensor.
9. Release the stay and close the cover.
Note: When closing the cover, set the gaskets to grooves in the bottom chassis, then tighten bolts.
BOTTOM
CHASSIS
GROOVE
.
Torque : 9.8 ±0.1 N m
GASKET
HEX BOLT
Connecting to NMEA2000 equipment
To connect NMEA2000 equipment to the sensor, use an optional NMEA2000 cable, M12-05BFFM
(φ6) or CB-05BFFM (φ10). Also, the gasket at the bottom of the antenna sensor must be replaced.
1. Do steps 1 to 5 on pages 16 and 17.
2. Fabricate the cable M12-05BFFM (φ6) or CB-05BFFM (φ10) as shown below.
5
95
Cable M12-05BFFM
or CB-05BFFM
Drain wire
3. Pass the cable through the bottom of the chassis.
4. Insert wires of the cable M12-05BFFM (φ6) or CB-05BFFM (φ10) to the NMEA connector inside
the radar sensor, consulting the label on the connector for location. As for drain wire, attach
18
Download from Www.Somanuals.com. All Manuals Search And Download.
the crimp-on lug (pre-attached at the bottom of the chassis) to the drain wire, and fasten it with
the screw shown below.
A
view
NMEA connector
NMEA connector
Crimp-on lug
A
Drain wire
Fasten the drain wire with this screw.
NMEA cable
RF unit
5. Depending on the NMEA2000 used, replace the gasket as shown below.
DRS4A/6A/12A
Cable type
Gasket
M12-05BFFM (φ6)
CB-05BFFM (φ10)
Use the gasket supplied in the plastic Use the optional gasket. (Type: OP03-205,
bag inside the radar sensor.
Code No.: 001-025-790)
DRS25A
Cable type
Gasket
M12-05BFFM (φ6)
CB-05BFFM (φ10)
Use the gasket supplied in the plastic Use the optional gasket. (Type: OP03-206,
bag inside the radar sensor. Code No.: 001-035-290)
6. Refer to the illustration shown on next page, and attach the gasket to the two-way cable
inserting the cable into the slits on the gasket.
7. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF
chassis.
This height should be lower than the
RF unit when installed to the bottom
of the sensor.
Cable
Gasket
Washer
RF unit
Gasket
8. Do steps 8 and 9 on page 18.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3 Wiring of Power Supply Unit PSU-013 (for
DRS25A)
1. Detach the body cover by hand.
2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it.
3. Unfasten four pan head screws (M14x10) to remove two cable clamps.
Body cover
Shield cover
Pan head screws
(M4x10, 4 pcs.)
Cable clamps
Pan head screws
(M3x8, 6 pcs.)
4. Connect the cable VL3P-VV-S2X2C-AA50 and MOD-ASW0002 cables (supplied) to appropri-
ate connectors in the power supply unit as shown below.
1: Red
2: N. C.
White
Black
3: Blue
2: Black
1: White
VL3P-VV-S2X2C-AA50 cable
MOD-ASW0002 cable
(Power)
5. Remove two cable clamps, shield cover and body cover in that order.
6. Connect other cables.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4 Wiring inside Power Supply Unit PSU-012
(Option)
1. Detach the body cover by hand.
2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it.
3. Unfasten two pan head screws (M4x12) to remove the cable clamp.
Body cover
Shield cover
Pan head screw
(M4x12, 2 pcs.)
Cable clamp
Pan head screw
(M3x8, 6 pcs.)
4. Connect the cable VL3P-VV-S2X2C-AA050 (supplied) to the power connector in the PSU-
012.
For black wire
For white wire
Put the cable VL3P-VV-S2X2C-AA050 here at the shield part.
5. Remount the cable clamp, shield cover and body cover in that order.
6. Connect other cables.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
A-1
CODE NO.
TYPE
001-025-270-00
CP03-32101
03HA-X-9401 -0
1/1
工事材料表
INSTALLATION MATERIALS
数量
番 号
NO.
名 称
NAME
型名/規格
略 図
OUTLINE
用途/備考
REMARKS
Q'TY
DESCRIPTIONS
テイコウ組品
120 OHM-1007#24-L50
CODE
1
2
3
4
1
RESISTOR ASSEMBLY
NO.
000-167-746-10
M10 SUS304
M10 SUS304
ミガキ平座金
4
4
4
FLAT WASHER
000-167-232-10
000-864-131-00
CODE
NO.
M10 SUS304
バネ座金
M10 SUS304
SPRING WASHER
000-167-233-10
000-864-261-00
CODE
NO.
六角スリワリ ボルト
M10X25 SUS304
CODE
HEX.BOLT (SLOTTED
HEAD)
NO.
000-162-883-10
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
03HA-X-9401
FURUNO ELECTRIC CO .,LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
A-2
CODE NO.
TYPE
001-025-780-00
CP03-32601
03GY-X-9401 -2
1/2
RSB-118-092/093/094
工事材料表
INSTALLATION MATERIALS
数量
Q'TY
番 号
NO.
名 称
NAME
型名/規格
DESCRIPTIONS
03-001-3002-0 ROHS
略 図
OUTLINE
用途/備考
REMARKS
シールワッシャ
03-001-3002-0
1
2
SEAL WASHER
4
1
4
1
4
4
4
4
3
1
300-130-020-10
300-130-020-00
CODE
NO.
防蝕ゴム
03-142-3001-0 ROHS
CODE
CORROSION-PROOF
RUBBER MAT
NO.
100-275-580-10
キャップ
CAP
040-4010
3
CODE
NO.
000-164-929-10
テイコウ組品
120 OHM-1007#24-L50
CODE
4
RESISTOR ASSEMBLY
NO.
000-167-746-10
バネ座金
M12 SUS304
CODE
5
SPRING WASHER
NO.
000-167-397-10
ミガキマル平座金
FLAT WASHER
M12 SUS304
CODE
6
NO.
000-167-446-10
六角ナット 1シュ
HEX.NUT
M12 SUS304
CODE
7
NO.
000-167-491-10
六角ボルト(全ネジ)
HEX. BOLT
M12X60 SUS304
CODE
8
NO.
000-162-813-10
ミガキ平座金
M6 SUS304
CODE
9
FLAT WASHER
NO.
000-158-854-10
バネ座金
M6 SUS304
CODE
10
SPRING WASHER
NO.
000-158-855-10
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
03GY-X-9401
FURUNO ELECTRIC CO .,LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
A-3
CODE NO.
TYPE
001-025-780-00
CP03-32601
03GY-X-9401 -2
2/2
RSB-118-092/093/094
工事材料表
INSTALLATION MATERIALS
数量
Q'TY
番 号
NO.
名 称
NAME
型名/規格
DESCRIPTIONS
略 図
OUTLINE
用途/備考
REMARKS
六角ナット 1シュ
M6 SUS304
11
12
13
HEX.NUT
1
1
1
CODE
NO.
000-158-856-10
六角ボルト
HEX.BOLT
M6X25 SUS304
CODE
NO.
000-162-871-10
アース線
RW-4747-1
CODE
GROUND WIRE
NO.
000-566-000-01
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
03GY-X-9401
FURUNO ELECTRIC CO .,LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
A-4
CODE NO.
TYPE
03HA-X-9402 -0
1/1
RADAR SENSOR
DRS2D/4D
工事材料表
INSTALLATION MATERIALS
数量
Q'TY
番 号
NO.
名 称
NAME
型名/規格
略 図
OUTLINE
用途/備考
REMARKS
DESCRIPTIONS
選択 TO BE SELECTED
選択 TO BE SELECTED
選択 TO BE SELECTED
選択 TO BE SELECTED
ケーブル組品
MOD-ASW0001-100+
CODE
1
2
3
4
1
1
1
1
CABLE ASSY.
NO.
000-167-635-00
ケーブル組品
MOD-ASW0001-150+
CODE
CABLE ASSY.
NO.
000-167-636-00
ケーブル組品
MOD-ASW0001-200+
CODE
CABLE ASSY.
NO.
000-167-637-00
ケーブル組品
MOD-ASW0001-300+
CODE
CABLE ASSY.
NO.
000-167-638-00
標準は15mであるが必要により選択可
STANDARD LENGTH IS 15M. OTHER LENGTHS ARE ALSO AVAILABLE.
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
03HA-X-9402
FURUNO ELECTRIC CO .,LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
A-5
CODE NO.
TYPE
03HC-X-9402 -0
1/1
RADAR SENSOR
DRS25A
工事材料表
INSTALLATION MATERIALS
数量
Q'TY
番 号
NO.
名 称
NAME
型名/規格
略 図
OUTLINE
用途/備考
REMARKS
DESCRIPTIONS
*選択 TO BE
SELECT
ケーブル組品
MOD-ASW0002-100+
CODE
1
2
3
4
CABLE ASSY.
1
1
1
1
NO.
000-167-639-00
*選択 TO BE
SELECT
ケーブル組品
MOD-ASW0002-150+
CODE
CABLE ASSY.
NO.
000-167-640-00
*選択 TO BE
SELECT
ケーブル組品
MOD-ASW0002-200+
CODE
CABLE ASSY.
NO.
000-167-641-00
*選択 TO BE
SELECT
ケ^ブル組品
MOD-ASW0002-300+
CODE
CABLE ASSY.
NO.
000-167-642-00
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
03HC-X-9402
FURUNO ELECTRIC CO .,LTD.
Download from Www.Somanuals.com. All Manuals Search And Download.
D-1
Download from Www.Somanuals.com. All Manuals Search And Download.
D-2
Download from Www.Somanuals.com. All Manuals Search And Download.
D-3
Download from Www.Somanuals.com. All Manuals Search And Download.
D-4
2/Apr/08 R.Esumi
Download from Www.Somanuals.com. All Manuals Search And Download.
D-5
Oct.15'07 R.Esumi
Download from Www.Somanuals.com. All Manuals Search And Download.
S-1
( - ) 2
( + ) 1
J 3
Download from Www.Somanuals.com. All Manuals Search And Download.
S-2
( - ) 2
( + ) 1
J 3
Download from Www.Somanuals.com. All Manuals Search And Download.
( - ) 2
( + ) 1
J 3
Download from Www.Somanuals.com. All Manuals Search And Download.
S-4
( - ) 2
( + ) 1
J 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
The paper used in this manual
is elemental chlorine free.
・FURUNO Authorized Distributor/Dealer
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
Telephone : +81-(0)798-65-2111
Fax
: +81-(0)798-65-4200
A : JAN 2008
.
Printed in Japan
All rights reserved.
B1 : APR. 17, 2008
Pub. No. IME-35670-B1
(HIMA ) DRS-2D/4D/4A-25A
*00016745111*
*00016745111*
* 0 0 0 1 6 7 4 5 1 1 1 *
Download from Www.Somanuals.com. All Manuals Search And Download.
|