Fujitsu Server RX600 S5 User Manual

Operating manual - English  
PRIMERGY RX600 S5 Server  
Operating Manual  
January 2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before reading this manual  
For your safety  
This manual contains important information for safely and correctly using this  
product.  
Carefully read the manual before using this product. Pay particular attention to  
the accompanying manual "Safety notes and other important information" and  
ensure these safety notes are understood before using the product. Keep this  
manual and the manual "Safety notes and other important information" in a safe  
place for easy reference while using this product.  
Radio interference  
This product is a "Class A" ITE (Information Technology Equipment). In a  
domestic environment this product may cause radio interference, in which case  
the user may be required to take appropriate measures.  
VCCI-A  
Aluminum electrolytic capacitors  
The aluminum electrolytic capacitors used in the product's printed circuit board  
assemblies and in the mouse and keyboard are limited-life components. Use of  
these components beyond their operating life may result in electrolyte leakage  
or depletion, potentially causing emission of foul odor or smoke.  
As a guideline, in a normal office environment (25°C) operating life is not  
expected to be reached within the maintenance support period (5 years).  
However, operating life may be reached more quickly if, for example, the product  
is used in a hot environment. The customer shall bear the cost of replacing  
replaceable components which have exceeded their operating life. Note that  
these are only guidelines, and do not constitute a guarantee of trouble-free  
operation during the maintenance support period.  
High safety use  
This product has been designed and manufactured for general uses such as  
general office use, personal use, domestic use and normal industrial use. It has  
not been designed or manufactured for uses which demand an extremely high  
level of safety and carry a direct and serious risk to life or body if such safety  
cannot be ensured.  
RX600 S5  
Operating Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
These uses include control of nuclear reactions in nuclear power plants,  
automatic airplane flight control, air traffic control, traffic control in mass  
transport systems, medical devices for life support, and missile guidance control  
in weapons systems (hereafter, "high safety use"). Customers should not use  
this product for high safety use unless measures are in place for ensuring the  
level of safety demanded of such use. Please consult the sales staff of Fujitsu if  
intending to use this product for high safety use.  
Measures against momentary voltage drop  
This product may be affected by a momentary voltage drop in the power supply  
caused by lightning. To prevent a momentary voltage drop, use of an AC  
uninterruptible power supply is recommended.  
(This notice follows the guidelines of Voltage Dip Immunity of Personal  
Computer issued by JEITA, the Japan Electronics and Information Technology  
Industries Association.)  
Technology controlled by the Foreign Exchange and Foreign Trade  
Control Law of Japan  
Documents produced by Fujitsu may contain technology controlled by the  
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which  
contain such technology should not be exported from Japan or transferred to  
non-residents of Japan without first obtaining authorization in accordance with  
the above law.  
Harmonic Current Standards  
This product conforms to harmonic current standard JIS C 61000-3-2.  
Only for the Japanese market: About SATA hard disk drives  
The SATA version of this server supports hard disk drives with SATA / BC-SATA  
storage interfaces. Please note that the usage and operation conditions differ  
depending on the type of hard disk drive used.  
Please refer to the following internet address for further information on the  
usage and operation conditions of each available type of hard disk drive:  
http://primeserver.fujitsu.com/primergy/harddisk/  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Only for the Japanese market:  
I
Although described in this manual, some sections do not apply to the  
Japanese market. These options and routines include:  
CSS (Customer Self Service)  
USB Flash Module (UFM)  
Replacing the lithium battery  
RX600 S5  
Operating Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Contents  
1
1.1  
1.2  
1.3  
1.4  
1.5  
Concept and target groups for this manual . . . . . . . . . 11  
2
Overview of the installation steps . . . . . . . . . . . . . . . 25  
3
3.1  
3.2  
3.3  
3.4  
3.5  
3.6  
3.7  
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 27  
ENERGY STAR . . . . . . . . . . . . . . . . . . . . . . . . . 35  
4
Unpacking the server . . . . . . . . . . . . . . . . . . . . . 42  
4.1  
4.2  
Rack installation/removal of server . . . . . . . . . . . . . . 43  
Rack system requirements . . . . . . . . . . . . . . . . . . . 43  
Installation in PRIMECENTER/DataCenter rack . . . . . . . . . 46  
Installation in 3rd party racks . . . . . . . . . . . . . . . . . . 51  
4.2.1  
4.2.2  
4.2.3  
4.3  
Connecting devices to the server . . . . . . . . . . . . . . . 53  
4.4  
Connecting the server to the mains . . . . . . . . . . . . . . 55  
4.4.1  
Installation requirements . . . . . . . . . . . . . . . . . . . . . 55  
RX600 S5  
Operating Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
4.4.2  
4.5  
5
5.1  
5.1.1  
Control elements and indicators . . . . . . . . . . . . . . . . 63  
Indicators on the accessible drives/components . . . . . . . 67  
Rear of server . . . . . . . . . . . . . . . . . . . . . . . . . . . 69  
ID indicator and button . . . . . . . . . . . . . . . . . . . . 71  
Indicators on the hot-plug power supply units . . . . . . . . . 73  
5.1.1.1  
5.1.1.2  
5.1.1.3  
5.1.1.4  
5.1.2  
5.1.2.1  
5.1.2.2  
5.1.2.3  
5.1.2.4  
5.2  
5.3  
5.3.1  
5.3.2  
Configuring the server . . . . . . . . . . . . . . . . . . . . . 78  
Configuring the SAS/SATA RAID controller card . . . . . . . . . 78  
the ServerView Installation Manager . . . . . . . . . . . . . . . 79  
Configuring the server and installing the operating system  
5.3.3  
5.4  
Property and data protection . . . . . . . . . . . . . . . . . . 83  
6
6.1  
6.2  
BIOS Setup security functions . . . . . . . . . . . . . . . . . 83  
7
Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 85  
7.1  
7.2  
7.3  
7.4  
Power-on indicator remains unlit . . . . . . . . . . . . . . . . 85  
Server switches itself off . . . . . . . . . . . . . . . . . . . . 86  
Screen remains blank . . . . . . . . . . . . . . . . . . . . . . 86  
Flickering stripes on monitor screen . . . . . . . . . . . . . 87  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
7.5  
7.6  
7.7  
7.8  
7.9  
8
8.1  
8.1.1  
Identifying the defective CSS component . . . . . . . . . . 109  
Installing a new memory module . . . . . . . . . . . . . . . 119  
Reinstalling the memory board in question . . . . . . . . . 119  
Adding a memory board . . . . . . . . . . . . . . . . . . . 120  
8.1.1.1  
8.1.1.2  
8.1.2  
8.1.2.1  
8.1.2.2  
8.1.3  
8.1.3.1  
8.1.3.2  
8.1.3.3  
8.1.3.4  
8.1.4  
8.1.4.1  
8.1.4.2  
8.1.4.3  
8.1.4.4  
8.1.5  
8.1.5.1  
8.1.5.2  
8.1.5.3  
8.1.5.4  
8.1.5.5  
8.1.5.6  
8.2  
8.2.1  
8.2.2  
8.2.2.1  
8.2.2.2  
8.2.3  
Non-hot-plug components . . . . . . . . . . . . . . . . . . . 121  
Identifying the defective CSS component . . . . . . . . . . . . 122  
Replacing a non-hot-plug expansion card . . . . . . . . . . . . 122  
Removing a non-hot-plug expansion card . . . . . . . . . . 122  
Installing a non-hot-plug expansion card . . . . . . . . . . . 125  
Replacing SFP+ transceiver modules . . . . . . . . . . . . . . 126  
Removing an SFP+ transceiver module . . . . . . . . . . . 126  
8.2.3.1  
RX600 S5  
Operating Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
8.2.3.2  
Installing SFP+ transceiver modules . . . . . . . . . . . . 129  
8.3  
8.3.1  
8.3.2  
Opening/Closing the server . . . . . . . . . . . . . . . . . . 134  
Opening the server . . . . . . . . . . . . . . . . . . . . . . . 134  
Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 136  
9
Appendix: server specification . . . . . . . . . . . . . . . . 137  
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
1
Preface  
The scalable PRIMERGY RX600 S5 server is an Intel-based rack server for  
critical company scenarios, e.g. as database management system for medium  
or large-sized databases or as a consolidation basis to run an immensely large  
number of different applications using virtualization technologies.  
Thanks to its highly developed hardware and software components, the server  
offers a high level of data security and availability. These include hot-plug HDD  
modules, hot-plug system fans, and also hot-plug power supply units, the  
Server Management ServerView Suite, Prefailure Detection and Analysis (PDA)  
and Automatic Server Reconfiguration and Restart (ASR&R).  
Security functions in the BIOS Setup and on the system board protect the data  
on the server against manipulation. Additional security is provided by the  
lockable rack door.  
The server occupies 4 height units (HU) in the rack.  
1.1  
Concept and target groups for this manual  
This operating manual describes how to install, set up and operate your server.  
This operating manual is intended for those responsible for installing the  
hardware and ensuring that the system runs smoothly. It contains all the  
information you need to put your PRIMERGY RX600 S5 into operation.  
To understand the various expansion options, you will need to be familiar with  
the fields of hardware and data transmission and you will require a basic  
knowledge of the underlying operating system.  
RX600 S5  
Operating Manual  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Documentation overview  
Preface  
1.2  
Documentation overview  
More information on your PRIMERGY RX600 S5 can be found in the following  
documents:  
"Quick Start Hardware - PRIMERGY RX600 S5" leaflet  
"はじめにお読みくださ-PRIMERGY RX600 S5" for the Japanese market  
(only included as a printed copy)  
"Quick Start Software - Quick Installation Guide" DVD booklet  
(only included with the ServerView Suite as a printed copy) except for the  
Japanese market  
"Safety Notes and Regulations" manual  
" 安全上のご注意 " for the Japanese market  
"Warranty" manual  
" 保証書 " for the Japanese market  
"ServerView Suite Local Service Concept - LSC" manual  
"Returning used devices" manual and "Service Desk" leaflet  
" サポート&サービス " for the Japanese market  
"PRIMERGY RX600 S5 Server Operating Manual"  
"PRIMERGY RX600 S5 Server Options Guide"  
"System Board D2870 for PRIMERGY RX600 S5 Technical Manual"  
"D2870 BIOS Setup Utility for PRIMERGY RX600 S5" manual  
12  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
Preface  
Documentation overview  
I
PRIMERGY manuals are available in PDF format on the  
ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the  
ServerView Suite supplied with every server.  
If you no longer have the ServerView Suite DVDs, you can obtain the  
relevant current versions using the order number U15000-C289 (the  
order number for the Japanese market: please refer to the configurator  
The PDF files of the manuals can also be downloaded free of charge  
from the Internet. The overview page showing the online documentation  
available on the Internet can be found using the URL (for EMEA market):  
http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can  
be accessed using the Industry standard servers navigation option.  
For the Japanese market please use the URL:  
Further sources of information:  
PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2  
Manual for the monitor  
Documentation for the boards and drives  
Operating system documentation  
Information files in your operating system  
RX600 S5  
Operating Manual  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Features  
Preface  
1.3  
Features  
Customer Self Service (CSS)  
The PRIMERGY Customer Self Service (CSS) concept enables you to identify  
and replace the affected component yourself in the case of certain error  
scenarios.  
In the CSS concept, you can replace the following components yourself in the  
event of an error:  
Hot-plug hard disk drives  
Hot-plug power supply units  
Hot-plug Memory modules  
Hot-plug System fans  
Expansion cards (as soon as released)  
For information on replacing these components, see chapter "CSS  
components" on page 91.  
CSS indicators on the control panel and on the back of the PRIMERGY server  
provide you with information if a CSS event arises (for more information on the  
behavior of these indicators, see chapter "Starting up and operation" on  
page 63 and the "ServerView Suite Local Service Concept - LSC" manual on  
the ServerView Suite DVD 2).  
Your server is equipped with a ServerView Local Service Display, which enables  
you to identify the type of component affected by the error directly on the server  
(for more information, see the "ServerView Suite Local Service Concept - LSC"  
manual on the ServerView Suite DVD 2).  
In addition, CSS errors are displayed in the ServerView Operations Manager,  
the server management software from Fujitsu.  
In the event of errors, the ServerView Operations Manager refers you directly to  
the affected component and its order information in the Illustrated Spares  
catalog of the server in question. (This feature is not available for the Japanese  
market.)  
14  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
     
Preface  
Features  
System board  
The features of the system board are described in the technical manual for the  
system board D2870 for the hardware and in the BIOS Setup manual for the  
firmware.  
Hot-plug PCI slots  
The server has ten PCI-Express slots, where two of them are hot-plug slots.  
These hot-plug PCI-Express slots allow installation and removal of boards  
during operation when the operating system supports this function (for further  
details see section "Hot-plug expansion cards" on page 107).  
Hard disk drives  
The server can be equipped with up to 8 SAS/SATA HDD modules. Each HDD  
module can accommodate a SAS/SATA hard disk drive with a 2.5-inch format.  
The modules are connected to the SAS/SATA backplane wirelessly. This allows  
HDD modules to be plugged in or pulled out easily.  
The hard disk system is designed for SAS/SATA with one channel for each hard  
disk drive.  
If the server has the corresponding RAID configuration, HDD modules can also  
be replaced during operation.  
SAS/SATA controller card (optionally with RAID controller)  
The SAS/SATA controller card for operating up to eight SAS/SATA hard disk  
drives can be alternately without or with RAID functionality. In case of RAID  
functionality the levels 0, 1, 1E, 5, 6, 10, 50 and 60 are supported.  
Battery Backup Units  
Up to two intelligent Battery Backup Units (iBBUs) back up the memory contents  
of their corresponding RAID controllers in the event of power failure (option).  
Accessible drives/components  
A number of mounting locations are available:  
An installation slot for a ServerView Local Service Display (standard)  
An installation slot for a slimline CD/DVD/BD drive (standard)  
A 5.25-inch bay for a magnetic tape drive (option)  
RX600 S5  
Operating Manual  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
Features  
Preface  
The accessible drives/components integrated in these locations cannot be  
replaced during operation.  
Power supply  
The server has up to four hot-plug power supply units that automatically switch  
to a mains voltage of 100 - 127 V / 200 - 240 V. This ensures redundant power  
supply. If one power supply unit is defective, the other(s) then guarantee(s)  
unimpaired operation. The faulty power supply unit can be replaced during  
operation (for further details see "Hot-plug power supply units" on page 93).  
Cooling  
Each processor has a heat sink. Further cooling for the installed processors is  
provided by hot-plug fans (optionally in a redundant configuration).  
Temperature sensors variably adjust the fans. If a temperature sensor fails or is  
removed, the fans affected run at maximum speed so as to provide the greatest  
possible protection for the hardware. When the housing is open, all the fans run  
at maximum speed.  
If a fan fails, unimpaired further operation is ensured. A defective fan module  
can be replaced during operation (for further details see "Hot-plug fans" on  
page 97).  
High level of availability and data security  
When memory data is accessed, 1-bit errors in the main memory are identified  
and automatically corrected with the ECC (Error Correcting Code) method. The  
patented memory scrubbing function regularly starts up the EDC mechanism  
(Error Detection Code) and thus ensures continuous data integrity.  
The memory modules used support SDDC technology (Chipkill™), which  
further increases the effectiveness of memory error monitoring and correction.  
Support is likewise provided for hot-spare memory technology, in which a  
memory module is used like a replacement module. If a memory module fails,  
the module with the defective memory is automatically deactivated and the  
replacement module is activated (provided it has been configured for  
appropriately in the BIOS). The deactivated memory module is no longer used  
and the faulty memory module can be replaced at the next opportunity. In order  
to be able to use the hot-spare memory function, all occupied DIMM slots must  
have an identical memory configuration.  
16  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
           
Preface  
Features  
Memory modules can be protected against failure through mirroring (memory  
mirroring, requires two or four memory modules).  
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in  
the event of an error and automatically "hides" the defective system  
components.  
The PDA (Prefailure Detection and Analysis) technology from Fujitsu analyzes  
and monitors all components that are critical for system reliability.  
The SAS/SATA controller card supports the RAID levels 0, 1, 1E, 5, 6, 10, 50  
and 60 thus increasing system availability and reliability.  
Additional reliability is provided by the hot-plug HDD modules, fans and power  
supply units.  
RX600 S5  
Operating Manual  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Features  
Preface  
iRMC S2 with integrated management LAN connector  
I
The features of the iRMC S2 Advanced Video Redirection and Remote  
Storage are available as an option.  
The iRMC S2 (integrated Remote Management Controller) is a BMC with  
integrated management LAN connector and expanded functionality that was  
previously only available with additional plug-in cards. In this way, the iRMC S2  
enables complete control of PRIMERGY servers, regardless of system status,  
and thus particularly the control of PRIMERGY servers that are in the "out-of-  
band" system status.  
Major functions supported by the iRMC S2 include the following:  
Browser access via iRMC S2-s own Web server  
Secure communication (SSH, SSL)  
Power Management for the managed server (depending on its system  
status)  
Power Consumption Management  
Connecting virtual drives as remote storage  
Text-based and graphic console bypass (Advanced Video Redirection)  
Command Line Interface (CLI)  
Simple, interactive or script-based iRMC S2 configuration  
Customer Self Service (CSS)  
iRMC S2-s own user management  
Multi-computer, global iRMC S2 user administration using an LDAP  
Directory Service  
Automatic network configuration via DNS / DHCP  
Power supply of the iRMC S2 via the system standby supply  
Full-coverage alarm management  
System Event Log (SEL) reading and processing  
More information about the iRMC S2 can be found in the "iRMC S2 - integrated  
Remote Management Controller" user’s guide (on the ServerView Suite DVD 2  
under Industry Standard Servers - Software - ServerView Suite - Out-Of-Band  
Management).  
18  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
     
Preface  
Features  
Server management  
Server management is implemented using the ServerView Operations Manager  
supplied and the PDA (Prefailure Detection and Analysis) technology from  
Fujitsu. PDA reports the threat of a system error or overload at an early stage,  
allowing preventive measures to be taken.  
The ServerView Operations Manager enables the management of all  
PRIMERGY servers in the network via a central console. The ServerView  
Operations Manager supports the following functions:  
Round-the-clock monitoring, regardless of server status  
High-performance, graphical console bypass (AVR) protected by  
HTTPS/SSL (128 bit)  
Remote storage via USB  
Remote power on  
Temperature monitoring of the CPU and the surrounding area  
Detailed status and error reports for processors and main memory  
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)  
in the event of failure of memory modules or processors  
Power monitoring  
End-of-life monitoring of fans with prompt notification before failure  
Watchdog timer for monitoring the operating system with ASR&R  
Further information on the ServerView Operations Manager is provided in the  
associated documentation.  
RX600 S5  
Operating Manual  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Features  
Preface  
ServerView Installation Manager  
You can configure the PRIMERGY server quickly and precisely with the  
ServerView Installation Manager software provided. User-guided menus are  
available for installing the server operating system (for further details see  
Service and support  
PRIMERGY servers are service-friendly and modular, enabling quick and easy  
maintenance.  
For easier and immediate recognition, handles and locks (touch points) are  
color coded. Green touch points are for components that can be replaced  
without tools as well as for hot-plug components that can be replaced or  
inserted during operation without the need for tools (see also "CSS  
components" on page 91).  
You can use the ServerView Local Service Display on the front panel of the  
server to check the status of the key system components at any time without  
opening the housing. Further information on ServerView Local Service Display  
is provided in the associated documentation.  
For further information, please refer to the diagnosis LEDs on the hot-plug  
components (power supply units, fans, expansion cards, HDD modules).  
The ServerView Update Manager supplied with the Fujitsu utilities supports a  
fast remote BIOS update via the LAN interface; the BIOS can also be updated  
locally via USB. The optional ServerView Remote Management remote testing  
and diagnostic system enables you to remotely maintain your server.  
20  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
     
Preface  
Features  
ServerView Remote Management  
ServerView Remote Management is the remote management solution from  
relevant hardware components integrated on the system board allow remote  
monitoring and maintenance as well as fast restoration of operation in the event  
of errors.  
Remote monitoring and maintenance avoids time-consuming and costly on-site  
repairs and reduces service costs. This leads to a reduction in the total cost of  
ownership and an excellent return on investment for the remote management  
solution.  
The administrator can access all system information and information from the  
sensors such as fan speeds or voltages via the iRMC S2's Web interface (see  
section "iRMC S2 with integrated management LAN connector" on page 18).  
You can also start the text-based or graphic console bypass (Advanced Video  
Redirection, AVR) and connect virtual drives as remote storage.  
I
The features of the iRMC S2 Advanced Video Redirection and Remote  
Storage are available as an option.  
More information about the iRMC S2 can be found in the "iRMC S2 -  
integrated Remote Management Controller" user’s guide (on the  
ServerView Suite DVD 2 under Industry Standard Servers - Software -  
ServerView Suite - Out-Of-Band Management).  
RX600 S5  
Operating Manual  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Notational conventions  
Preface  
1.4  
Notational conventions  
The following notational conventions are used in this manual:  
Text in italics  
indicates commands or menu items.  
"Quotation marks" indicate names of chapters and terms that are being  
emphasized.  
Ê
describes activities that must be performed in the order  
shown.  
V
CAUTION! pay particular attention to texts marked with this symbol.  
Failure to observe this warning may endanger your life,  
destroy the system or lead to the loss of data.  
I
indicates additional information, notes and tips.  
1.5  
Technical data  
Electrical data (hot-plug power supply unit)  
Rated voltage range  
Frequency  
100 - 127 V / 200 - 240 V  
50 Hz - 60 Hz  
3.1 A (240 V)  
14 A (240 V)  
Rated current (basic configuration)  
Max. rated current  
Active power min. (typical configuration) 750 W  
Active power max. (typical configuration) 1950 W  
Rated active power max.  
Apparent power (typical configuration)  
Heat dissipation  
3360 W (14 A x 240 V)  
1990 VA  
750 W/h = 2559 btu/h  
1950 W/h = 6654 btu/h  
3360 W/h = 11465 btu/h  
Main power fuse  
Protection class  
16 A  
I
22  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
             
Preface  
Technical data  
Compliance with regulations and standards  
Product safety and  
ergonomics  
IEC 60950-1/2 / EN 60950-1/2, UL/CSA 60950-  
1/2, CNS 14336 / GB 4943 / EN 50371  
Electromagnetic  
compatibility  
Interference emissions EN 55022 class A; FCC class A; CNS 13438 class  
A; VCCI class A; AS/NZS CISPR 22 class A;  
GB 9254 class A; GB 17625; ETSI EN 300 386  
V1.3.1  
Interference immunity EN 55024, EN 300386  
Harmonic current  
EN 61000-3-2  
Flicker  
EN 61000-3-3  
CE marking to EU  
directives  
Low Voltage Directive 2006/95/EC (product safety)  
Electromagnetic compatibility 2004/108/EC  
Environmental conditions ETSI 300 019-2-3 Class 3.1 (T3.1)  
Noise emission  
ETSI 300 753 Class 3.1  
RX600 S5  
Operating Manual  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Technical data  
Preface  
Dimensions / Weight  
Rack (W x D x H)  
482.6 mm (Bezel) / 444.8 mm (Body) x 770.0 mm x  
176.0 mm  
728 mm  
4 U  
Mounting depth rack  
Height unit rack  
19" rackmount  
Yes  
Mounting cable depth 100 mm (1000 mm rack recommended)  
rack  
Weight  
min. 32 kg; max. 46 kg (actual weight may vary  
depending on configuration)  
Rack integration kit  
rack integration kit as option  
I
Rack integration kit is standard for the  
japanese market.  
Ventilation clearance  
At least 200 mm on the front and rear.  
Ambient conditions  
Environment class 3K2  
Environment class 2K2  
EN 60721 / IEC 721 Part 3-3  
EN 60721 / IEC 721 Part 3-2  
Temperature:  
Operation (3K2)  
Transport (2K2)  
Humidity  
10 °C .... 35 °C  
-25 °C .... 60 °C  
10% ... 85% (non condensing)  
Condensation during operation must be avoided!  
Noise level  
Sound power level LWAd (ISO 9296)  
< 6.2 B (standby)  
< 6.6 B (operation)  
Sound pressure level at bystander position LpAm  
(ISO 9296) (at < 23 °C)  
< 46 dB(A) (standby)  
< 51 dB(A) (operation)  
24  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
     
2
Overview of the installation steps  
This chapter contains an overview of the steps necessary to install your server.  
Links guide you to sections where you can find more detailed information on the  
individual steps:  
Ê
At first, please take notice of the safety instructions in chapter "Important  
information" on page 27 and following.  
Ê
Ê
Unpack all parts, check the contents of the package for visible transport  
damage and check whether the items delivered match the details on the  
delivery note (see section "Unpacking the server" on page 42).  
Ê
Ê
Ê
Make sure that all necessary manuals (see "Documentation overview" on  
page 12) are available; print out the PDF files if required.  
Fit the server in the rack (see section "Rack installation/removal of server"  
on page 43).  
Wire the server. Follow the instructions in the sections "Connecting devices  
to the server" on page 53 and "Notes on connecting/disconnecting cables"  
on page 61.  
Ê
Ê
Ê
Connect the server to the mains (see section "Connecting the server to the  
mains" on page 55).  
Familiarize yourself with the controls and indicators on the front and rear of  
the server (see section "Control elements and indicators" on page 63).  
Configure the server and install the desired operating system and  
applications. Here you can choose from two possibilities:  
Remote installation with the ServerView Installation Manager:  
With the ServerView Suite DVD 1 provided, you can configure the server  
and install the operating system in a convenient manner.  
Details on how to operate the ServerView Installation Manager, as well  
as some additional information, are included in the "ServerView Suite  
Installation Manager" user’s guide (on ServerView Suite DVD 2 under  
Industry Standard Servers - Software - ServerView Suite - Server Installation  
and Deployment).  
RX600 S5  
Operating Manual  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Overview of the installation steps  
Configuration information can also be found in section "Configuring the  
server and installing the operating system with the ServerView  
Installation Manager" on page 79.  
Local configuration and installation with or without ServerStart (see  
section "Configuring the server and installing the operating system with  
the ServerView Installation Manager" on page 79 or section "Configuring  
the server and installing the operating system without the ServerView  
Installation Manager" on page 80).  
I
You will find more information on installing the server remotely or  
locally in the "ServerView Suite Installation Manager" user’s guide  
(on the ServerView Suite DVD 2 under Industry Standard Servers -  
Software - ServerView Suite - Server Installation and Deployment).  
26  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
3
Important information  
In this chapter you will find essential information regarding safety when working  
on your server.  
3.1  
Safety instructions  
I
The following safety instructions are also provided in the manual "Safety  
Notes and Regulations" or " 安全上のご注意 ".  
This device meets the relevant safety regulations for IT equipment. If you have  
any questions about whether you can install the server in the intended  
environment, please contact your sales outlet or our customer service team.  
V
CAUTION!  
The actions described in this manual shall be performed by technical  
specialists. A technical specialist is a person who is trained to install  
the server including hardware and software.  
Repairs to the device that do not relate to CSS failures shall be  
performed by service personnel. Please note that unauthorized  
interference with the system will void the warranty and exempt the  
manufacturer from all liability.  
Any failure to observe the guidelines in this manual, and any improper  
repairs could expose the user to risks (electric shock, energy  
hazards, fire hazards) or damage the equipment.  
Before installing/removing internal options to/from the server, turn off  
the server, all peripheral devices, and any other connected devices.  
Also unplug all power cords from the power outlet. Failure to do so  
can cause electric shock.  
RX600 S5  
Operating Manual  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Safety instructions  
Before starting up  
Important information  
V
CAUTION!  
During installation and before operating the device, observe the  
instructions on environmental conditions for your device (see  
"Technical data" on page 22).  
If the server has been moved from a cold environment, condensation  
may form both inside and on the outside of the machine.  
Wait until the server has acclimatized to room temperature and is  
absolutely dry before starting it up. Material damage may be caused  
to the server if this requirement is not met.  
Only transport the server in the original packaging or in packaging  
that protects it from impacts and jolts.  
Installation and operation  
V
CAUTION!  
This unit should not be operated in ambient temperatures above  
35 °C.  
If the unit is integrated into an installation that draws power from an  
industrial power supply network with an IEC309 connector, the power  
supply's fuse protection must comply with the requirements for non-  
industrial power supply networks for type A connectors.  
The unit automatically adjusts itself to a mains voltage in a range of  
100 - 127 V / 200 - 240 V. Ensure that the local mains voltage lies  
within these limits.  
This device must only be connected to properly grounded power  
outlets or insulated sockets of the rack's internal power supply with  
tested and approved power cords.  
Ensure that the device is connected to a properly grounded power  
outlet close to the device.  
28  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Important information  
Safety instructions  
V
CAUTION!  
Ensure that the power sockets on the device and the properly  
grounded power outlets are freely accessible.  
The On/Off button or the main power switch (if present) does not  
isolate the device from the mains power supply. To disconnect it  
completely from the mains power supply, unplug all network power  
plugs from the properly grounded power outlets.  
Always connect the server and the attached peripherals to the same  
power circuit. Otherwise you run the risk of losing data if, for example,  
the server is still running but a peripheral device (e.g. memory  
subsystem) fails during a power outage.  
Data cables must be adequately shielded.  
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2  
standards or ISO/IEC 11801 standard respectively. The minimum  
requirement is a Category 5 shielded cable for 10/100 Ethernet, or a  
Category 5e cable for Gigabit Ethernet.  
Route the cables in such a way that they do not create a potential  
hazard (make sure no-one can trip over them) and that they cannot  
be damaged. When connecting the server, refer to the relevant  
instructions in this manual.  
Never connect or disconnect data transmission lines during a storm  
(risk of lightning hazard).  
Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can  
get inside the server (risk of electric shock, short circuit).  
In emergencies (e.g. damaged casing, controls or cables, penetration  
of liquids or foreign bodies), switch off the server immediately, remove  
all power plugs and contact your sales outlet or customer service  
team.  
RX600 S5  
Operating Manual  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety instructions  
Important information  
V
CAUTION!  
Proper operation of the system (in accordance with IEC 60950-1/2  
resp. EN 60950-1/2) is only ensured if the casing is completely  
assembled and the rear covers for the installation slots have been  
fitted (electric shock, cooling, fire protection, interference  
suppression).  
Only install system expansions that satisfy the requirements and  
rules governing safety and electromagnetic compatibility and those  
relating to telecommunication terminals. If you install other  
expansions, they may damage the system or violate the safety  
regulations. Information on which system expansions are approved  
for installation can be obtained from our customer service center or  
your sales outlet.  
The components marked with a warning notice (e.g. lightning symbol)  
may only be opened, removed or exchanged by authorized, qualified  
personnel. Exception: CSS components can be replaced.  
The warranty is void if the server is damaged during installation or  
replacement of system expansions.  
Only set screen resolutions and refresh rates that are specified in the  
operating manual for the monitor. Otherwise, you may damage your  
monitor. If you are in any doubt, contact your sales outlet or customer  
service center.  
Before installing/removing internal options to/from the server, turn off  
the server, all peripheral devices, and any other connected devices.  
Also unplug all power cords from the outlet. Failure to do so can  
cause electric shock.  
Do not damage or modify internal cables or devices. Doing so may  
cause a device failure, fire, or electric shock.  
Devices inside the server remain hot after shutdown. Wait for a while  
after shutdown before installing or removing internal options.  
The circuit boards and soldered parts of internal options are exposed  
and can be damaged by static electricity. Before handling them, first  
touch a metal part of the server to discharge static electricity from  
your body.  
Do not touch the circuitry on boards or soldered parts. Hold the  
metallic areas or the edges of the circuit boards.  
30  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Important information  
Safety instructions  
V
CAUTION!  
Install the screw removed during installation/detaching Internal  
Options in former device/position. To use a screw of the different kind  
causes a breakdown of equipment.  
The installation indicated on this note is sometimes changed to the  
kind of possible options without notice.  
Batteries  
CAUTION!  
V
Incorrect replacement of batteries may lead to a risk of explosion. The  
batteries may only be replaced with identical batteries or with a type  
recommended by the manufacturer (see the technical manual for the  
system board).  
Do not throw batteries into the trash can.  
Batteries must be disposed of in accordance with local regulations  
concerning special waste.  
Replace the lithium battery on the system board in accordance with  
the instructions in the technical manual for the system board.  
All batteries containing pollutants are marked with a symbol (a  
crossed-out garbage can). In addition, the marking is provided with  
the chemical symbol of the heavy metal decisive for the classification  
as a pollutant:  
Cd Cadmium  
Hg Mercury  
Pb Lead  
RX600 S5  
Operating Manual  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Safety instructions  
Important information  
Working with CDs/DVDs/BDs and optical drives  
When working with devices with optical drives, these instructions must be  
followed.  
V
CAUTION!  
Only use CDs/DVDs/BDs that are in perfect condition, in order to  
prevent data loss, equipment damage and injury.  
Check each CD/DVD/BD for damage, cracks, breakages etc. before  
inserting it in the drive.  
Note that any additional labels applied may change the mechanical  
properties of a CD/DVD/BD and cause imbalance.  
Damaged and imbalanced CDs/DVDs/BDs can break at high drive  
speeds (data loss).  
Under certain circumstances, sharp CD/DVD/BD fragments can  
pierce the cover of the optical drive (equipment damage) and can fly  
out of the device (danger of injury, particularly to uncovered body  
parts such as the face or neck).  
High humidity and airborne dust levels are to be avoided. Electric  
shocks and/or server failures may be caused by liquids such as water,  
or metallic items, such as paper clips, entering a drive.  
Shocks and vibrations are also to be avoided.  
Do not insert any objects other than the specified CDs/DVDs/BDs.  
Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray  
roughly.  
Do not disassemble the optical drive.  
Before use, clean the optical disk tray using a soft, dry cloth.  
As a precaution, remove disks from the optical drive when the drive  
is not to be used for a long time. Keep the optical disk tray closed to  
prevent foreign matter, such as dust, from entering the optical drive.  
Hold CDs/DVDs/BDs by their edges to avoid contact with the disk  
surface.  
32  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Important information  
Safety instructions  
Do not contaminate the CD/DVD/BD surface with fingerprints, oil,  
dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to  
the edge. Do not use benzene, thinners, water, record sprays,  
antistatic agents, or silicone-impregnated cloth.  
Be careful not to damage the CD/DVD/BD surface.  
Keep the CDs/DVDs/BDs away from heat sources.  
Do not bend or place heavy objects on CDs/DVDs/BDs.  
Do not write with ballpoint pen or pencil on the label (printed) side.  
Do not attach stickers or similar to the label side. Doing so may cause  
rotational eccentricity and abnormal vibrations.  
When a CD/DVD/BD is moved from a cold place to a warm place,  
moisture condensation on the CD/DVD/BD surface can cause data  
read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth  
then let it air dry. Do not dry the CD/DVD/BD using devices such as a  
hair dryer.  
To avoid dust, damage, and deformation, keep the CD/DVD/BD in its  
case whenever it is not in use.  
Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to  
prolonged direct sunlight or near heating appliances are to be  
avoided.  
I
You can prevent damage from the optical drive and the CDs/DVDs/BDs,  
as well as premature wear of the disks, by observing the following  
suggestions:  
Only insert disks in the drive when needed and remove them after  
use.  
Store the disks in suitable sleeves.  
Protect the disks from exposure to heat and direct sunlight.  
Laser information  
The optical drive complies with IEC 60825-1 laser class 1.  
V
CAUTION!  
The optical drive contains a light-emitting diode (LED), which under  
certain circumstances produces a laser beam stronger than laser  
class 1. Looking directly at this beam is dangerous.  
Never remove parts of the optical drive casing!  
RX600 S5  
Operating Manual  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Safety instructions  
Important information  
Modules with Electrostatic-Sensitive Devices  
Modules with electrostatic-sensitive devices are identified by the following  
sticker:  
Figure 1: ESD label  
When you handle components fitted with ESDs, you must always observe the  
following points:  
Switch off the system and remove the power plugs from the power outlets  
before installing or removing components with ESDs.  
You must always discharge static build-up (e.g. by touching a grounded  
object) before working with such components.  
Any devices or tools that are used must be free of electrostatic charge.  
Wear a suitable grounding cable that connects you to the external chassis of  
the system unit.  
Always hold components with ESDs at the edges or at the points marked  
green (touch points).  
Do not touch any connectors or conduction paths on an ESD.  
Place all the components on a pad which is free of electrostatic charge.  
I
For a detailed description of how to handle ESD components, see the  
relevant European or international standards (EN 61340-5-1,  
ANSI/ESD S20.20).  
34  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
Important information  
ENERGY STAR  
Other important information:  
During cleaning, observe the instructions in section "Cleaning the server" on  
page 81.  
Keep this operating manual and the other documentation (such as the  
technical manual, documentation DVD) close to the device. All  
documentation must be included if the equipment is passed on to a third  
party.  
3.2  
ENERGY STAR  
Products that have been certified compliant with ENERGY STAR  
and identified as such are in full compliance with the specification  
at shipping. Note that energy consumption can be affected by  
software that is installed or any changes that are made to the  
hardware configuration or BIOS or energy options subsequently.  
In such cases, the properties guaranteed by ENERGY STAR can  
no longer be assured.  
The "ServerView Operations Manager" user guide contains  
instructions for reading out measurement values, including those  
relating to current energy consumption and air temperatures.  
Either the Performance Monitor or the Task Manager can be used  
to read out CPU utilization levels.  
3.3  
CE conformity  
The system complies with the requirements of the EC directives  
2004/108/EC regarding "Electromagnetic Compatibility" and  
2006/95/EC "Low Voltage Directive". This is indicated by the CE  
marking (CE = Communauté Européenne).  
RX600 S5  
Operating Manual  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
FCC Class A Compliance Statement  
Important information  
3.4  
FCC Class A Compliance Statement  
If there is an FCC statement on the device, it applies to the products covered in  
this manual, unless otherwise specified herein. The statement for other  
products will appear in the accompanying documentation.  
NOTE:  
This equipment has been tested and found to comply with the limits for a  
"Class A" digital device, pursuant to Part 15 of the FCC rules and meets all  
requirements of the Canadian Interference-Causing Equipment Standard  
ICES-003 for digital apparatus. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation. This  
equipment generates, uses and can radiate radio frequency energy and, if not  
installed and used in strict accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no warranty that  
interference will not occur in a particular installation. If this equipment does  
cause harmful interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is encouraged to try  
to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between equipment and the receiver.  
Connect the equipment into an outlet on a circuit different from that to which  
the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
Fujitsu is not responsible for any radio or television interference caused by  
unauthorized modifications of this equipment or the substitution or attachment  
of connecting cables and equipment other than those specified by Fujitsu. The  
correction of interferences caused by such unauthorized modification,  
substitution or attachment will be the responsibility of the user.  
The use of shielded I/O cables is required when connecting this equipment to  
any and all optional peripheral or host devices. Failure to do so may violate FCC  
and ICES rules.  
WARNING:  
This is a class A product. In a domestic environment this product may cause  
radio interference in which case the user may be required to take adequate  
measures.  
36  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
Important information  
Transporting the server  
3.5  
Transporting the server  
V
CAUTION!  
Only transport the server in its original packaging or in packaging that  
protects it from impacts and jolts. Do not unpack the server until it is at  
its installation location.  
If you need to lift or transport the server, ask other people to help you.  
Never lift or carry the device by the handles on the front panel.  
RX600 S5  
Operating Manual  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Notes on installing the server in the rack  
Important information  
3.6  
Notes on installing the server in the rack  
V
CAUTION!  
For safety reasons, at least two people are required to install the  
server in the rack because of its weight and size.  
(For the Japanese market, please refer to " 安全上の注意およびその  
他の重要情報 ".)  
Never lift the server into the rack using the handles on the front panel.  
When connecting and disconnecting cables, observe the relevant  
instructions in the "Important Information" chapter of the technical  
manual for the corresponding rack. The technical manual is supplied  
with the corresponding rack.  
When installing the rack, make sure that the anti-tilt mechanism is  
correctly fitted.  
For safety reasons, no more than one unit may be removed from the  
rack at any one time during installation and maintenance work.  
If several units are simultaneously removed from the rack, there is a  
risk that the rack could tip over.  
The rack must be connected to the power supply by an authorized  
specialist (electrician).  
If the server is integrated into an installation that draws power from an  
industrial power supply network with an IEC309 type connector, the  
power supply's fuse protection must comply with the requirements for  
non-industrial power supply networks for the type A connector.  
38  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
Important information  
Environmental protection  
3.7  
Environmental protection  
Environmentally-friendly product design and development  
This product has been designed in accordance with the Fujitsu standard for  
"environmentally friendly product design and development". This means that  
key factors such as durability, selection and labeling of materials, emissions,  
packaging, ease of dismantling and recycling have been taken into account.  
This saves resources and thus reduces the harm done to the environment.  
Further information can be found at:  
http://ts.fujitsu.com/products/standard_servers/index.html (for the EMEA market)  
http://primeserver.fujitsu.com/primergy/concept/ (for the Japanese market)  
Energy-saving information  
Devices that do not need to be constantly switched on should be switched off  
until they are needed as well as during long breaks and after completion of work.  
Packaging information  
This packaging information doesn’t apply to the Japanese market.  
Do not throw away the packaging. You may need it later for transporting the  
system. If possible, the equipment should only be transported in its original  
packaging.  
Information on handling consumables  
Please dispose of printer consumables and batteries in accordance with the  
applicable national regulations.  
In accordance with EU directives, batteries must not be disposed of with  
unsorted domestic waste. They can be returned free of charge to the  
manufacturer, dealer or an authorized agent for recycling or disposal.  
RX600 S5  
Operating Manual  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Environmental protection  
Important information  
All batteries containing pollutants are marked with a symbol (a crossed-out  
garbage can). They are also marked with the chemical symbol for the heavy  
metal that causes them to be categorized as containing pollutants:  
Cd Cadmium  
Hg Mercury  
Pb Lead  
Labels on plastic casing parts  
Please avoid sticking your own labels on plastic parts wherever possible, since  
this makes it difficult to recycle them.  
Returns, recycling and disposal  
Please handle returns, recycling and disposal in accordance with local  
regulations.  
The device must not be disposed of with domestic waste. This  
device is labeled in compliance with European directive  
2002/96/EC on waste electrical and electronic equipment (WEEE).  
This directive sets the framework for returning and recycling used  
equipment and is valid across the EU. When returning your used  
you. Further information can be found at  
http://ts.fujitsu.com/recycling.  
Details regarding the return and recycling of devices and consumables within  
Europe can also be found in the "Returning used devices" manual, via your local  
Fujitsu branch or from our recycling center in Paderborn:  
Fujitsu Technology Solutions  
Recycling Center  
D-33106 Paderborn  
Tel. +49 5251 525 1410  
Fax +49 5251 525 32 1410  
40  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
4
Hardware installation  
V
CAUTION!  
Follow the safety instructions in the chapter "Important information"  
on page 27.  
Do not expose the server to extreme environmental conditions (see  
"Ambient conditions" on page 24). Protect the server from dust,  
humidity and heat.  
Make sure that the server is acclimatized for the time indicated in this  
table before putting it into operation.  
Temperature difference (°C) Minimum acclimatization time  
(hours)  
5
3
5
10  
15  
7
20  
8
25  
30  
9
10  
Table 1: Acclimatization time  
In the table "Acclimatization time", the temperature difference refers  
to the difference between the operating environment temperature and  
the temperature to which the server was exposed previously (outside,  
transport or storage temperature).  
RX600 S5  
Operating Manual  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Unpacking the server  
Hardware installation  
4.1  
Unpacking the server  
V
CAUTION!  
Follow the safety instructions in chapter "Important information" on  
page 27.  
The server must always be lifted or carried by at least two people.  
(For the Japanese market, please refer to " 安全上の注意 ".)  
Do not unpack the server until it is at its installation location.  
Ê
Ê
Transport the server to the place where you want to set it up.  
Unpack all individual parts.  
Keep the original packaging in case you want to transport the server again  
(applies only to EMEA market).  
Ê
Ê
Check the delivery for any damage during transport.  
Check whether the items delivered match the details on the delivery note.  
The product name and serial number of the product can be found on the ID card  
(see section "ID card" on page 64).  
Ê
Notify your supplier immediately should you discover that the items delivered  
do not correspond to the delivery note.  
42  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
           
Hardware installation  
Rack installation/removal of server  
4.2  
Rack installation/removal of server  
V
CAUTION!  
Please observe the safety information and notes on rack mounting in  
chapter "Important information" on page 27.  
At least two people are needed to install / remove the server in the  
rack. (For the Japanese market, please refer to " 安全上の注意および  
その他の重要情報 ".)  
The rack may tip over if more than one unit is removed at the same  
time.  
The server may not occupy the top height units of the rack  
(38HU/42HU PRIMECENTER Rack, DataCenter Rack, 19-inch  
standard rack (for the Japanese market)), as otherwise boards  
cannot be replaced.  
4.2.1 Rack system requirements  
The rack systems from Fujitsu PRIMECENTER Rack, DataCenter Rack and  
19-inch standard rack (for the Japanese market) support the installation of  
PRIMERGY servers. Installation in most current rack systems from other  
manufacturers (3rd party racks) is also supported.  
To accommodate the ventilation concept and ensure proper ventilation, any  
unused areas in the rack must be sealed using dummy covers.  
The power is supplied via the multiple socket outlets fitted in the rack.  
Fujitsu rack systems  
The main features of PRIMECENTER Rack, DataCenter Rack and 19-inch  
standard rack (for the Japanese market) are as follows:  
support systems that can be mounted without tools  
support systems having a linear alignment feature to ensure that they can  
be adjusted to different rack depths  
PRIMECENTER Rack and DataCenter Rack provide an enhanced cable  
management in the lateral rack area.  
RX600 S5  
Operating Manual  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Rack installation/removal of server  
Hardware installation  
I
For PRIMECENTER Racks and DataCenter Racks:  
The mounting of the rails in the different racks is described in the next  
sections. Installation of the cable management is described in detail in  
I the Technical Manual for the respective rack.  
For 19-inch standard rack (for the Japanese market):  
For information on mounting of the rails in the 19-inch standard rack (for  
the Japanese market) please refer to the "Rack mount guide".  
3rd party racks  
Certain general conditions must be met:  
Installation dimensions (see the dimensions shown in figure 2 on page 45):  
1
Front of rack  
2
Rear of rack  
A
Rack depth (comparison PRIMECENTER Rack 940/1000/1100 mm)  
Rack width (comparison PRIMECENTER rack 700 mm)  
Clearance for 19" installation level  
Front 19" installation level  
B
C
C1  
C2  
D
Rear 19" installation level  
Cable routing area (cable area depth) and ventilation  
Space for front panel and ventilation  
Space for right and left support systems  
PRIMERGY rack installation depth  
Front left support upright  
E
F
P
a1  
a2  
b1  
b2  
Front right support upright  
Rear left support upright  
Rear right support upright  
44  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
Hardware installation  
Rack installation/removal of server  
+/- 1,6mm  
Figure 2: Mechanical requirements  
RX600 S5  
Operating Manual  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Rack installation/removal of server  
Hardware installation  
You must ensure that the safety mechanisms on the server, e.g. stoppers or  
retaining systems, are functioning correctly.  
The shape of the rack support uprights must ensure that the support  
systems can be bolted to the front.  
The support systems have a linear alignment feature to ensure that they can  
be adjusted to different rack depths.  
No cable management support (delivered with the mounting kit).  
Climatic conditions:  
An unobstructed air intake in the rack front and air discharge in the rear  
cover of the rack are essential for ventilation of the installed server.  
In general, the ventilation concept ensures that the necessary cooling is  
achieved by the horizontal self-ventilation of the installed devices (air flow  
from the front to the rear).  
Power supply:  
For installation in 3rd party racks, you must ensure that the appropriate  
socket strips are present.  
4.2.2 Installation in PRIMECENTER/DataCenter rack  
For installation in a PRIMECENTER/DataCenter rack, the following parts are  
required:  
Support bracket  
One support system on the left and one on the right  
M5 centering fixtures (screws with integrated plugwashers)  
I
The descriptions and figures in this section refer to the current  
support system. For other support systems you will find the  
appropriate description in the packaging of the rack mounting kit.  
For information on mounting of the rails in the 19-inch standard rack  
(for the Japanese market) please refer to the "Rack mount guide".  
General information regarding server installation in the rack is  
included in the technical manual for the appropriate rack.  
For information on mounting of the server in the 19-inch standard rack  
(for the Japanese market) please refer to the Rack mount guide.  
46  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
Hardware installation  
Rack installation/removal of server  
Fitting the support bracket  
When mounting the left support system in the corresponding rack, the supplied  
support bracket must first be mounted flush with the underside of the device on  
the rear left support upright.  
2
1
Figure 3: Fitting the support bracket  
Ê
Position the support bracket at the corresponding height on the rear left  
support upright, (place knob in the corresponding hole) (1) and secure it with  
the two supplied M5 centering fixtures (2).  
RX600 S5  
Operating Manual  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Rack installation/removal of server  
Installing the support systems  
Hardware installation  
Figure 4: Fit the left support system in the PRIMECENTER/DataCenter rack  
Ê
Ê
Position the left-hand support system in the support bracket (insert retaining  
bolts) - see (1).  
Clamp the left-hand support system (2) between the front left support  
upright and the support bracket by pressing the support system together,  
positioning it on the front support upright and releasing it again. The support  
system automatically adjusts to the rack depth.  
I
The support system no longer has to be fixed to the front support  
upright because the easy lock engages and ensures a firm fit.  
48  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
Hardware installation  
Rack installation/removal of server  
Ê
Insert (3) the safety lock into the easy lock (snap fit).  
CAUTION!  
V
Ensure that the safety lock has been inserted before the server is  
inserted!  
Ê
Ê
Repeat the above steps for the right-hand support system (with the front and  
rear right support uprights).  
Fit the PRIMECENTER/DataCenter rack cable management as described in  
the Technical Manual for the corresponding rack.  
12  
11  
11  
8
1
Figure 5: Position of the cage nuts  
Ê
Ê
Fit the cage nuts for securing the server in the corresponding catches on the  
right and left support uprights.  
Insert the server (see "Inserting the server" on page 50).  
RX600 S5  
Operating Manual  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Rack installation/removal of server  
Inserting the server  
Hardware installation  
I
For the Japanese market:  
Refer to the "Rack Mounting Guide" for more detailed explanation and for  
other support systems.  
/
/
Figure 6: Inserting the server (a)  
5
4
3
4
2
Figure 7: Inserting the server (b)  
50  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
Hardware installation  
Rack installation/removal of server  
V
CAUTION!  
Ensure that the safety lock has been inserted before the server is  
V inserted (see figure 4 on page 48).  
CAUTION!  
At least two people are needed to position the server in the rack.  
(For the Japanese market, please refer to " 安全上の注意およびその他の  
重要情報 ".)  
Ê
Extend the telescopic rails completely to the front (1).  
I
They must click into place so that they can no longer be moved.  
Ê
Lower the server from above onto the projecting telescopic rails (2), (3). As  
you do this, the locking bar (4) engages.  
Ê
Ê
Ê
Push the locking mechanism of both telescopic rails up (5).  
Push the server as far as it will go into the rack (6).  
Fasten the server to the rack (7) using the two knurled screws (front panel).  
Torque: 0.25 Nm  
Ê
Route the cables as described in the Technical Manual for the rack in  
question with the server pushed in.  
4.2.3 Installation in 3rd party racks  
I
The support systems from Fujitsu are suitable for use in any 3rd party  
racks for standard servers (installation depth 714 - 785 mm) without  
restrictions.  
Ê
Refer to the manual from the rack manufacturer for details of the mechanical  
installation and the climatic conditions.  
V
CAUTION!  
When installing in 3rd party racks, it must be ensured that an air flow  
from the front to the back of the rack is guaranteed.  
Ê
Fit the required original parts (support bracket or cable management  
system).  
RX600 S5  
Operating Manual  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Rack installation/removal of server  
Hardware installation  
I
Under certain circumstances, you will not be able to use some of the  
parts from the rack installation kit supplied - you will need to use  
original 3rd party rack parts instead.  
Racks with installation depth of 735 mm  
The lengths of the telescopic rails do not need to be adjusted with respect to  
each other for the installation in rack systems with 735 mm installation depth.  
Ê
Secure the support systems as described in section "Installing the support  
systems" on page 48.  
Ê
Mount the server (see "Inserting the server" on page 50) and route the  
cables as described in the original manual of the rack.  
V
CAUTION!  
Ensure that the safety lock has been inserted before the server is  
inserted (see figure 4 on page 48).  
Racks with installation depth smaller/greater than 735 mm  
The support systems can be used for installation depths of 714 - 785 mm. The  
spring element of the support system is used to adjust the length as required.  
Ê
Secure the support systems as described in "Installing the support systems"  
on page 48.  
Ê
Mount the server (see "Inserting the server" on page 50) and route the  
cables as described in the original manual of the rack.  
V
CAUTION!  
Ensure that the safety lock has been inserted before the server is  
inserted (see figure 4 on page 48).  
52  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Hardware installation  
Connecting devices to the server  
4.3  
Connecting devices to the server  
The connectors for external devices are on the front and rear of the server. The  
additional connectors available on your server depend on the expansion cards  
installed (e.g. optional SAS connector).  
I
Some of the devices that can be connected may require special software,  
e.g. drivers (see the documentation for the connected device).  
/
0
Figure 8: Connectors on the front  
On the front of the server are a video connector (1) and three USB  
connectors (2).  
I
The two video connectors on the front and rear (see figure 9 on page 54)  
can only be used alternatively; the connector not used is automatically  
deactivated.  
RX600 S5  
Operating Manual  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Connecting devices to the server  
Hardware installation  
The standard connectors on the rear are marked with symbols, and one is color-  
coded:  
3
2
/
0
1
Figure 9: Connectors on the rear  
1
2
3
4x LAN connector  
4
5
Video connector (blue)  
Serial connector COM1  
2 x USB connector  
Management LAN connector  
Ê
Connect the data cables to the server and peripherals.  
I
Connect keyboard and mouse via USB. There are no separate PS/2  
connectors for them.  
Connecting the monitor  
Ê
Plug the data cable for the monitor into the video connector on the server.  
Alternatively, the video connector at the front or the rear of the server can be  
used.  
Ê
Connect the power cord of the monitor to a grounded mains outlet of the in-  
house mains and/or into the mains socket strip of the rack.  
54  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
           
Hardware installation  
Connecting the server to the mains  
4.4  
Connecting the server to the mains  
V
CAUTION!  
The server is automatically set to a mains voltage in the range 100 - 127  
V / 200 - 240 V. You may only operate the server if its rated voltage range  
corresponds to the local mains voltage.  
4.4.1 Installation requirements  
The power subsystem consists of:  
Power supply modules (PSU)  
A power distribution board (PDB)  
The power supply subsystem can support up to 4 PSUs which all connect to the  
PDB. The total system is rated 100 - 127 V / 200 - 240 V, 50/60 Hz, 28/14 A.The  
minimum system configuration requires installation of at least two PSUs. The  
PSU is considered hot-swappable(see "Hot-plug power supply units" on  
page 93). The system can be configured to support *True AC redundancy or  
non-AC redundancy.  
I
*True AC redundancy is recommended for systems used for critical  
business applications. This will result in the system to continue operation  
during a power failure as the redundant part of the subsystem is plugged  
I into a separate AC source [e.g. uninterruptable power supply (UPS)).  
Refer to tables below for maximum DC loading for both AC redundant  
and AC non redundant configurations.  
Installation requirements for AC redundant configurations  
The AC redundant configuration is with two PSU plugged into a main AC source  
and two other PSUs plugged into a separate AC source (e.g. UPS).  
PSU Configuration  
1+1 (2 PSUs)  
Max. DC Loading  
830W  
DC Redundancy  
Yes  
Yes  
2+2 (4 PSUs)  
1580W  
Table 2: Maximum DC Loading Requirements  
RX600 S5  
Operating Manual  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Connecting the server to the mains  
Hardware installation  
Installation requirements for AC non redundant configurations  
For systems not requiring AC redundancy, the power supply subsystem can be  
installed with up to 4 PSUs. The PSUs can be connected to a single or multiple  
AC sources.  
PSU Configuration  
1+1 (2 PSUs)  
Max. DC Loading  
830W  
DC Redundancy  
Yes  
Yes  
Yes  
2+1 (3 PSUs)  
1580W  
3+1 (4 PSUs)  
2320W  
Table 3: Maximum DC Loading Requirements  
Three power supply modules are capable of handling the maximum power  
requirements for a fully configured PRIMERGY RX600 S5 server system, which  
include the following:  
Four processors  
1024 GB of memory  
Eleven PCIe add-in cards (including the SAS/SATA RAID controller card)  
Eight hard disk drives  
One optical drive  
One tape drive  
The hot swap feature allows the user to replace a failed power supply module  
without affecting the system functionality.  
56  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Hardware installation  
Connecting the server to the mains  
AC source related power supply configuration and system load limits  
The system configuration and load is limited by the number of AC mains power  
sources available as indicated in the following table.  
Number AC redundant systems  
of power (requires 2 AC sources)  
supply  
AC non-redundant systems  
(connected to 1 AC source)  
Max. DC  
Installation  
Max. DC  
Installation  
modules  
installed  
loading to  
support AC  
redundancy  
requirements loading for AC requirements  
non-redundant  
systems  
2
3
4
830W  
2 PSUs  
connected to  
mains (1+1)  
1580W  
2320W  
2320W  
2 PSUs  
connected to  
mains (1+1)  
N/A  
N/A  
3 PSUs  
connected to  
mains (2+1)  
1580W  
2 PSUs  
4 PSUs  
connected to  
mains  
connected to  
mains (3+1)  
2 PSUs  
connected to  
an isolated AC  
source  
e.g. UPS (2+2)  
Table 4: System power supply configuration and system load limits  
Installation in PRIMECENTER/Datacenter rack  
Please follow the installation requirements for connection to the mains  
described in the rack manuals.  
RX600 S5  
Operating Manual  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting the server to the mains  
Hardware installation  
Installation in 3rd party racks without main connection according to  
IEC309 or outside of racks  
I
1. These additional installation requirements ONLY apply when 4 PSUs  
are connected to a high line voltages (220V or higher).  
2. These requirements DO NOT apply when PSUs are connected to low  
line voltages (100-127V and 200V) OR if at least one PSU is  
connected into a separate AC source (e.g. UPS).  
V
CAUTION!  
These additional installation requirements are REQUIRED to avoid risk  
of high leakage current which may result in electric shock.  
1. Systems REQUIRE being installed in a location having equipotential  
bonding (such as a telecommunication center, a dedicated computer room  
or a *RESTRICTED ACCESS LOCATION.  
* Definition of RESTRICTED ACCESS LOCATION is a location for  
equipment where both of the following apply:  
Access can only be gained by SERVICE PERSONS or by USERS who  
have been instructed about the reasons for the restrictions applied to the  
location and about any precautions that shall be taken; and  
Access is through the use of a TOOL or lock and key, or other means of  
security, and is controlled by the authority responsible for the location.  
2. The building installation shall provide means for connection to protective  
earth as follows: Connection to protective earth can be provided by the  
socket-outlet that provides power to the PSU. A service person requires  
checking the socket-outlet to make sure it has a protective earth. If the  
socket-outlet does not have a protective earth, then the service person  
requires arranging:  
Installation of a protective earth conductor from the system to the  
building installation. The grounding bolt is located on the chassis rear left  
side wall designated by the  
symbol.  
58  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Hardware installation  
Connecting the server to the mains  
3
1
2
Figure 10: Installing a protective earth conductor  
Ê
Ê
Ê
Loosen the first nut and remove it (1).  
Plug the protective earth conductor onto the bolt (2).  
Replace the nut and tighten it (3).  
RX600 S5  
Operating Manual  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting the server to the mains  
Hardware installation  
4.4.2 Connecting the power cord  
Ê
Ê
Connect the power cord to the server power supply unit.  
Connect the mains plug to a grounded mains outlet in the in-house power  
supply network or a power outlet of the socket strip in the rack (see Technical  
Manual for the rack).  
Ê
Secure the power cords in the cable clamps so the insulated connectors  
cannot be disconnected from the server accidentally.  
Figure 11: Cable clamps to secure the power cords  
Ê
Ê
Thread the cable through the cable clamp as shown in figure 11.  
Pull the cable clamp tight to secure the power cord.  
Now the insulated connector cannot be disconnected from the server  
accidentally.  
I
You can loosen the cable clamp by opening the small locking lever.  
60  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
       
Hardware installation  
Notes on connecting/disconnecting cables  
4.5  
Notes on connecting/disconnecting cables  
V
CAUTION!  
Always read the documentation supplied with the device you wish to  
connect.  
Never connect, or disconnect cables during a thunderstorm.  
Never pull on a cable when disconnecting it. Always take hold of the  
cable by the plug.  
Follow the sequence described below to connect or disconnect external  
devices to or from the server:  
Be sure to wait for 10 seconds or more after shutdown before turning the  
server on.  
Connecting cables  
Ê
Ê
Ê
Ê
Ê
Turn off all power and equipment switches.  
Disconnect all power plugs from the properly grounded power outlets.  
Connect all cables to the server and peripherals.  
Plug all data communication cables into the utility sockets.  
Plug all power cords into the properly grounded power outlets.  
Disconnecting cables  
Ê
Ê
Ê
Ê
Turn off all power and equipment switches.  
Disconnect all power plugs from the properly grounded power outlets.  
Unplug all data communication cables from the utility sockets.  
Disconnect the relevant cables from the server and all the peripherals.  
I
For connecting or disconnecting LAN cables, the server need not to be  
powered off. To avoid loss of data teaming function has to be enabled.  
RX600 S5  
Operating Manual  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Notes on connecting/disconnecting cables  
Hardware installation  
62  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
5
Starting up and operation  
V
CAUTION!  
Follow the safety instructions in chapter "Important information" on  
page 27.  
5.1  
Control elements and indicators  
5.1.1 Front of server  
/
0
1
2
3 4  
#5  
#4  
#3  
#2  
#1  
#0  
#7  
#6  
6
5
Figure 12: Front - overall view  
1
2
ID card  
5
Video connector  
ServerView Local Service  
Display  
6
3x USB connector  
3
4
Optical drive activity indicator  
7
8
Hard disk indicators  
Tape (optional)  
Control panel (for details see  
page 64)  
The white numbers in figure 12 show the HDD slot assignment.  
RX600 S5  
Operating Manual  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                       
Control elements and indicators  
Starting up and operation  
/
0
1
2
3
4
7
6
5
Figure 13: Front - detailed view: control panel  
1
2
3
4
5
ID indicator  
6
Reset button  
NMI button  
On/Off button  
ID button  
CSS indicator  
7
8
9
Global Error indicator  
Hard disk activity indicator  
Power-on indicator  
ID card  
You can pull out the ID card (see figure 12 above) as far as it will go and push it  
back in again.  
The ID card contains various system information, such as product name, serial  
number and order number; in the Japanese market only the product name and  
the serial number.  
64  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
                       
Starting up and operation  
Control elements and indicators  
5.1.1.1 Control elements  
ID  
ID button  
ID LED lights up (blue) on the front and on the rear of the server  
when the ID button is pressed. Both ID indicators are  
synchronized.  
On/Off button  
When the system is switched off, it can be switched on again by  
pressing the On/Off button.  
When the system is operating, pressing the On/Off button will  
switch off the system.  
V
CAUTION!  
I Risk of loss of data!  
The On/Off button does not disconnect the server from the  
mains voltage. To disconnect from the mains completely,  
remove the power plug(s).  
RST  
NMI  
Reset button  
Pressing the reset button reboots the system.  
V
CAUTION!  
Risk of loss of data!  
NMI button  
CAUTION!  
V
Do not press! Risk of loss of data! The NMI button may only  
be used by service.  
RX600 S5  
Operating Manual  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Control elements and indicators  
Starting up and operation  
5.1.1.2 Indicators on the control panel  
ID  
ID indicator (blue)  
Lights up blue when the system has been selected by pressing the  
ID button. To deactivate, press the button again.  
The ID indicator can also be activated via the ServerView  
Operations Manager and the iRMC S2 Web interface and its  
status reported to the ServerView Operations Manager and the  
iRMC S2.  
Power-on indicator (green/orange/yellow)  
Lights up green – and also lights up orange for less than one  
second – when the server is switched ON.  
Flashes green when the system is in standby mode.  
Lights up orange when the server is in shutdown mode (operating  
system shutdown) or is switched off.  
Lights up yellow during power on delay.  
CSS  
CSS indicator (yellow)  
Lights up yellow if a prefailure event was detected for a CSS  
component that you can fix yourself (for reasons of precaution)  
with the CSS concept.  
Flashes yellow if an error was detected that you can fix  
yourself with the CSS concept.  
Does not light up when the system is OK.  
If the event is still acute after a power failure, the indicator is  
activated after the restart.  
The indicator also lights up in standby mode.  
For more information on the CSS concept, see "Customer Self  
Service (CSS)" on page 14.  
Hard disk activity indicator (green)  
Lights up green when an internal hard disk drive is accessed.  
66  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
         
Starting up and operation  
Control elements and indicators  
Global Error indicator (orange)  
!
Lights up orange if a prefailure event has been detected that  
requires (precautionary) service intervention.  
Flashes orange if an error was detected that requires service  
intervention.  
Does not light up if there is no critical event.  
If the event is still acute after a power failure, the indicator is  
activated after the restart.  
The indicator also lights up in standby mode.  
You can find more details on the indicated errors in the System  
Event Log (SEL), on the ServerView Local Service Display, in the  
ServerView Operations Manager or via the iRMC S2's Web  
interface.  
5.1.1.3 Indicators on the accessible drives/components  
DVD drive activity indicator  
Lights up green when the storage medium is being accessed.  
ServerView Local Service Display  
You can use the slot mechanism to pull out the ServerView Local Service  
Display from the server housing and read the information. Press the front of the  
module to release the lock.  
You can also pivot the ServerView Local Service Display down by an angle of  
120° from its normal position. This makes reading easier when the server is  
located very high in the rack.  
Further information on using the ServerView Local Service Display is provided  
in the "Customer Self Service (CSS)" manual.  
RX600 S5  
Operating Manual  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Control elements and indicators  
Starting up and operation  
5.1.1.4 Indicators on the hot-plug HDD modules  
ቢ ባ  
Figure 14: Indicators on a hot-plug HDD module  
1
2
HDD BUSY (green)  
Lights up: HDD in active phase (drive active, drive being accessed)  
Does not light: HDD inactive (drive inactive)  
HDD FAULT (orange)  
Does not light: no HDD error  
Lights up: HDD Faulty or Rebuild Stopped (drive defective/needs  
replacing, a rebuild process was stopped or the HDD module is not  
correctly inserted)  
Slow flashing: HDD Rebuild (the data is being restored after changing  
a drive)  
If a hard disk drive continuously indicates an error, the drive should be replaced  
as soon as possible. This can be done during operation (see "Hot-plug HDD  
modules" on page 100).  
68  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
       
Starting up and operation  
Control elements and indicators  
5.1.2 Rear of server  
5.1.2.1 Global Error indicator and CSS indicator  
/
0
Figure 15: Global Error indicator and CSS indicator  
1
CSS indicator (yellow)  
Lights up yellow if a prefailure event was detected for a CSS  
component that you can fix yourself (for reasons of precaution) with  
the CSS concept.  
Flashes yellow if an error was detected that you can fix yourself with  
the CSS concept.  
Does not light up when the system is OK.  
If the event is still acute after a power failure, the indicator is activated  
after the restart.  
The indicator also lights up in standby mode.  
For more information on the CSS concept, see "Customer Self Service  
(CSS)" on page 14.  
RX600 S5  
Operating Manual  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Control elements and indicators  
Starting up and operation  
2
Global Error indicator (orange)  
Lights up orange if a prefailure event has been detected that  
requires (precautionary) service intervention.  
Flashes orange if an error was detected that requires service  
intervention.  
Does not light up if there is no critical event.  
If the event is still acute after a power failure, the indicator is activated  
after the restart.  
The indicator also lights up in standby mode.  
You can find more details on the indicated errors in the System Event  
Log (SEL), on the ServerView Local Service Display, in the ServerView  
Operations Manager or via the iRMC S2's Web interface.  
70  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
Starting up and operation  
Control elements and indicators  
5.1.2.2 ID indicator and button  
/
0
Figure 16: ID indicator  
1
ID indicator (blue)  
Lights up blue when the system has been selected by pressing the ID  
button. To deactivate, press the ID button again.  
The ID indicator can also be activated via the ServerView Operations  
Manager and the iRMC S2 Web interface and its status reported to the  
ServerView Operations Manager and the iRMC S2.  
2
ID button  
RX600 S5  
Operating Manual  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Control elements and indicators  
Starting up and operation  
5.1.2.3 Indicators on the connector panel (LAN indicators)  
0
/
/
0
2
1
/
0
0
/
Figure 17: LAN indicators  
1
LAN speed  
Steady yellow signal in the event of a LAN transfer rate  
(system LAN/ of 1 Gbit/s.  
shared LAN)  
Steady green signal in the event of a LAN transfer rate  
of 100 Mbit/s.  
Remains dark in the event of a LAN transfer rate of  
10 Mbit/s.  
2
3
LAN  
Steady green signal when a LAN connection exists.  
Remains dark when no LAN connection exists.  
link/transfer  
(system LAN/  
shared LAN)  
Flashes green when LAN transfer takes place.  
LAN speed  
Steady green signal in the event of a LAN transfer rate  
(management of 100 Mbit/s.  
LAN)  
Remains dark in the event of a LAN transfer rate of  
10 Mbit/s.  
72  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
Starting up and operation  
Control elements and indicators  
4
LAN  
Steady green signal when a LAN connection exists.  
Remains dark when no LAN connection exists.  
Flashes green when LAN transfer takes place.  
link/transfer  
(management  
LAN)  
5.1.2.4 Indicators on the hot-plug power supply units  
/ 0  
1
Figure 18: Indicators on the power supply units  
1
2
DC power  
redundancy  
indicator  
Lights up green when PSU is running.  
Flashes green when PSU is in cold redundancy mode.  
PSU failure  
Lights up amber in case of a critical event (PSU  
and warnings shutdown).  
indicator  
Flashes amber in case of a warning event (operation  
continue).  
3
AC power  
supply input  
status  
Lights up green if AC power is present.  
Flashes green if AC power is not present.  
indicator  
RX600 S5  
Operating Manual  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Control elements and indicators  
Starting up and operation  
In normal server operation, LED 1 and 3 light up permanently, LED 2 does not  
light up. As soon as LED 2 indicates a fault by lighting up, the affected power  
supply unit should be replaced as soon as possible. This can be done during  
operation (see "Hot-plug power supply units" on page 93).  
74  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Starting up and operation  
Switching the server on and off  
5.2  
Switching the server on and off  
V
CAUTION!  
If nothing appears on the screen but flickering stripes after switching  
on the server, switch the server off immediately (see chapter  
"Troubleshooting and tips" on page 85).  
The On/Off button does not disconnect the server from the mains  
voltage. To completely disconnect it from the mains voltage, remove  
the power plug(s) from the socket(s).  
Do not move, strike, or shake the server when it is turned on. This can  
damage the hard disk in the server and cause data loss.  
Turn the server on when the temperature is in its operating  
environment range (1035°C). For details on the operating  
environment, refer to "Safety Precautions". When operating the  
device outside of this operating environment, the server may operate  
improperly, damage data etc. Furthermore, Fujitsu cannot be held  
responsible for any related damage, malfunction, or loss of data, etc.  
Be sure to wait for 10 seconds or more after shutdown before turning  
the server on.  
After connecting the power cords, press the On/Off button after it  
passes for more than 10 seconds.  
Switching the server on  
Starting up for the first time:  
For the Japanese market, please refer to " はじめにお読みください ".  
Ê
Ê
Ê
Press the On/Off button (see figure 13 on page 64).  
Insert ServerView Suite DVD 1 in the DVD drive.  
Follow the on-screen instructions (see also section "Configuring the  
server and installing the operating system with the ServerView  
Installation Manager" on page 79 or section "Configuring the server and  
installing the operating system without the ServerView Installation  
Manager" on page 80).  
RX600 S5  
Operating Manual  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Switching the server on and off  
System already installed:  
Press the On/Off button (see figure 13 on page 64).  
Ê
The server is switched on, performs a system test and boots the  
operating system.  
Switching the server off  
The power-on indicator lights up green (item 5 in figure 13 on page 64).  
Ê
Shut down the operating system properly.  
The server is switched off automatically and goes into standby mode. The  
power-on indicator lights up orange.  
I
If the operating system does not switch the server off automatically, press  
the On/Off button for at least four seconds and/or send a corresponding  
control signal.  
Other On/Off options  
Besides the On/Off button, the server can be switched ON and OFF in the  
following ways:  
Timer-controlled switch-on/off  
Using the ServerView Operations Manager or iRMC S2, you can configure  
that the server is switched on/off controlled by timer.  
Ring indicator  
The server is switched on by an internal or external modem.  
Wake up On LAN (WOL)  
The server is switched on by a command via the LAN (Magic PacketTM).  
After power failure  
The server automatically reboots following a power failure (depending on the  
settings in the BIOS or in iRMC S2).  
Power button override  
The system can be switched off by pressing and holding down the On/Off  
button (for approximately 4 - 5 seconds).  
76  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
Starting up and operation  
Switching the server on and off  
V
CAUTION!  
There is a risk that data may be lost.  
iRMC S2  
iRMC S2 offers various options for switching the server on and off, e.g. via  
the Power On Off page of the iRMC S2 Web interface.  
V
CAUTION when turning the power off (Windows Server 2008 or  
Windows Server 2003)!  
The operation of the power switch can be specified as "Do Nothing", "Ask  
me what to do" (only for Windows Server 2003), "Stand by", "Hibernate",  
and "Shutdown" depending on the OS settings. The default is  
"Shutdown".  
On this server, functions corresponding to "Stand by" and "Hibernate"  
are supported as BIOS and hardware functions. However, some drivers  
and software installed in the server do not support these functions. For  
this reason, functions corresponding to "Stand by" and "Hibernate" are  
unavailable on this server. When the operating mode is set to "Stand by"  
or "Hibernate", the system may operate improperly or hard disk data may  
be corrupted.  
For details about operating mode settings, refer to the manual supplied  
with the OS.  
RX600 S5  
Operating Manual  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring the server  
Starting up and operation  
5.3  
Configuring the server  
This section contains information about configuring the server and installing the  
operating system.  
I
Make sure that the energy saving functions are disabled in the BIOS  
Setup during server operation.  
5.3.1 Configuring the SAS/SATA RAID controller card  
The server comes with a SAS/SATA RAID controller with "MegaRAID  
functionality". You can configure the SAS/SATA RAID controller either before or  
during installation with the ServerView Installation Manager. Using the  
ServerView Installation Manager is recommended.  
I
A separate utility is available to the controller for MegaRAID  
configuration. For further information, refer to the "SAS Software User’s  
Guide" (on the ServerView Suite DVD 2 under Industry Standard Servers -  
Expansion Cards - Storage Adapters - LSI Configuration Software).  
Further information on modular RAID controllers is provided in the  
"Modular RAID Controller Installation Guide" (on the ServerView Suite  
DVD 2 under Industry Standard Servers - Expansion Cards - Storage Adapters  
I - LSI RAID / SCSI Controllers).  
Descriptions of operating systems not covered in the controller manual  
are provided in the corresponding readme files on the driver CDs.  
78  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
         
Starting up and operation  
Configuring the server  
5.3.2 Configuring the server and installing the operating  
system with the ServerView Installation Manager  
Using the ServerView Installation Manager on the ServerView Suite DVD 1  
provided, you can conveniently configure the server and install the operating  
system. This includes configuring the server-specific settings using the  
ServerView Configuration Manager and configuring the RAID controller using  
the ServerView RAID Manager.  
Advantages of the ServerView Installation Manager  
Wizard assisted configuration of your server hardware and disk arrays  
Wizard assisted installation of all leading server operating systems  
Wizard-assisted creation of configuration files for unattended installation of  
several PRIMERGY servers with identical hardware configurations.  
Installation of drivers and additional software.  
I
The software that can be installed depends on your server’s hardware  
I configuration. This configuration is detected automatically.  
Descriptions of operating systems not covered in the RAID controller  
manual are provided in the corresponding readme files on the driver  
CDs.  
To find out how to operate the ServerView Installation Manager and for further  
information, refer to the associated manual.  
If you are using the ServerView Installation Manager, you can skip the following  
section on how to configure the server and install the operating system.  
Continue from section "Cleaning the server" on page 81.  
RX600 S5  
Operating Manual  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Configuring the server  
Starting up and operation  
5.3.3 Configuring the server and installing the operating  
system without the ServerView Installation  
Manager  
Installing the operating system  
Ê
Ê
Ê
Insert the CD/DVD/BD for the operating system you want to install.  
Reboot the server.  
Follow the instructions on screen and in the manual for the operating  
system.  
80  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
     
Starting up and operation  
Cleaning the server  
5.4  
Cleaning the server  
V
CAUTION!  
Switch the server off and disconnect the power plugs from the properly  
grounded power outlets.  
Do not clean any interior parts yourself; leave this job to a service  
technician.  
Do not use any cleaning agents that contain abrasives or may corrode  
plastic.  
Ensure that no liquid enters the system. Ensure that the ventilation areas  
of the server and the monitor are clear.  
Do not use any cleaning sprays (including flammable types). It may  
cause a device failure or a fire.  
Clean the keyboard and the mouse with a disinfecting cloth.  
Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a  
cloth that has been moistened in a mild domestic detergent and then carefully  
wrung out.  
RX600 S5  
Operating Manual  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Cleaning the server  
Starting up and operation  
82  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
6
Property and data protection  
6.1  
Mechanical access protection  
The lockable rack door protects the server against unauthorized access.  
6.2  
BIOS Setup security functions  
The Security menu in BIOS Setup offers various options for protecting your data  
from unauthorized access. For example, you can assign passwords for users  
and administrators. By combining these options you can achieve optimum  
protection for your system.  
I
A detailed description of the Security menu and how to assign passwords  
can be found in the BIOS Setup documentation on the ServerView Suite  
DVD 2.  
RX600 S5  
Operating Manual  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
BIOS Setup security functions  
Property and data protection  
84  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
7
Troubleshooting and tips  
V
CAUTION!  
Follow the safety instructions in the "Safety notes and regulations"  
manual or " 安全上のご注意 " and in chapter "Important information" on  
page 27.  
If a fault occurs, attempt to resolve it using the measures described:  
in this chapter,  
in the documentation for the connected devices,  
in the help systems of the software used.  
If you fail to correct the problem, proceed as follows:  
Ê
Make a list of the steps performed and the circumstances that led to the fault.  
Also make a list of any error messages that were displayed.  
Ê
Ê
Switch off the server.  
Contact our customer service team.  
7.1  
Power-on indicator remains unlit  
The power-on indicator remains dark after you switch on your device.  
Power cable incorrectly connected  
Ê
Make sure that the power cable(s) is/are correctly connected to the server  
and the grounded power outlet(s).  
Power supply overloaded  
Ê
Ê
Disconnect the server power plug(s) from the grounded power outlet(s).  
Wait a few seconds before you plug it/them into the grounded power outlet(s)  
again.  
Ê
Switch on your server.  
RX600 S5  
Operating Manual  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Server switches itself off  
Troubleshooting and tips  
7.2  
Server switches itself off  
Server Management has detected an error  
Ê
Check the error list of System Event Log in ServerView Operations Manager  
or in the iRMC S2 web interface, and attempt to eliminate the error.  
7.3  
Screen remains blank  
Monitor is switched off  
Switch on your monitor.  
Ê
Screen has gone blank  
Ê
Press any key on the keyboard.  
or  
Ê
Deactivate screen saver. Enter the appropriate password.  
Brightness control is set to dark  
Ê
Set the brightness control on the monitor to light. For detailed information,  
refer to the operating manual supplied with your monitor.  
Power cable or monitor cable not connected  
Ê
Ê
Switch off the monitor and the server.  
Check whether the power cable is properly connected to the monitor and to  
the grounded power outlet.  
Ê
Check whether the monitor cable is properly connected to the server and  
monitor (if it is plugged in with a connector). If a separate graphics card is  
installed in the server, then the monitor cable must be connected to the  
graphics card.  
Ê
Switch on the monitor and the server.  
86  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
       
Troubleshooting and tips  
Flickering stripes on monitor screen  
7.4  
Flickering stripes on monitor screen  
V
CAUTION!  
Switch off the server immediately. Risk of damaging the server.  
Monitor does not support the set horizontal frequency  
Ê
Find out which horizontal frequency your monitor screen supports. You will  
find the horizontal frequency (also known as line frequency or horizontal  
deflection frequency) in the documentation for your monitor.  
Ê
Refer to the documentation for your operating system or the software for the  
screen controller for details of how to set the correct horizontal frequency for  
your monitor, and follow the procedure accordingly.  
7.5  
No screen display or display drifts  
The wrong horizontal frequency or resolution has been selected for the  
monitor or for the application program.  
Ê
Find out which horizontal frequency your monitor screen supports. You will  
find the horizontal frequency (also known as line frequency or horizontal  
deflection frequency) in the documentation for your monitor.  
Ê
Refer to the documentation for your operating system or the software for the  
screen controller for details of how to set the correct horizontal frequency for  
your monitor, and follow the procedure accordingly.  
RX600 S5  
Operating Manual  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Incorrect date and time  
Troubleshooting and tips  
7.6  
Incorrect date and time  
Ê
Set the date and time in the operating system or in the BIOS Setup under  
the Main menu, using System Date and System Time respectively.  
I
Note that the operating system may affect the system time. For example,  
the operating system time may deviate from the system time under Linux,  
and would overwrite the system time in the default setting on shutdown.  
If the date and time are still wrong after the server has been switched off and  
back on again, replace the lithium battery (for a description refer to the Technical  
Manual for the D2870 system board) or contact our customer service team.  
7.7  
Drives reported as "dead" when starting  
system  
RAID controller configuration incorrect  
Check and correct the settings for the drives using the RAID controller utility.  
Further information is provided in the manual for the RAID controller.  
Ê
88  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
       
Troubleshooting and tips  
Added drive reported as defective  
7.8  
Added drive reported as defective  
RAID controller is not configured for this drive  
The drive was probably installed when the system was switched off.  
Ê
Reconfigure the RAID controller for the drive using the corresponding utility.  
Information is provided in the documentation for the RAID controller.  
or  
Ê
Remove and reinstall the drive while the system is switched ON.  
If the hard disk drive continues to be shown as defective, then replace it (see  
"Hot-plug HDD modules" on page 100).  
7.9  
Error message on screen  
The meaning of the error message is explained in the documentation for the  
relevant components and programs on the ServerView Suite DVD 2.  
RX600 S5  
Operating Manual  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Error message on screen  
Troubleshooting and tips  
90  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
8
CSS components  
This chapter describes how to handle CSS components and how to identify  
defective CSS components and replace them yourself.  
I
Further information on the CSS concept is provided in the "ServerView  
Suite Local Service Concept - LSC" manual on the ServerView Suite  
DVD 2.  
For the latest information on optional products provided for the RX600 S5  
see the configurator of the server:  
(for the EMEA market)  
V (for the Japanese market)  
CAUTION!  
Do not disassemble the power supply unit. Doing so may cause  
electric shock.  
Do not damage or modify internal cables or devices.Doing so may  
cause a device failure, fire, or electric shock.  
Devices inside the server remain hot after shutdown. Wait for a while  
after shutdown before installing or removing internal options.  
The circuit boards and soldered parts of internal options are exposed  
and can be damaged by static electricity. Before handling them, first  
touch a metal part of the server to discharge static electricity from  
your body.  
Do not touch the circuitry on boards or soldered parts. Hold the  
metallic areas or the edges of the circuit boards.  
If devices are installed or disassembled using methods other than  
those outlined in this chapter, the warranty will be invalidated.  
The installation indicated on this note is sometimes changed to the  
kind of possible options without notice.  
Follow the safety instructions in the chapter "Important information"  
on page 27.  
RX600 S5  
Operating Manual  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CSS components  
In the PRIMERGY RX600 S5 server, the following components are considered  
to be CSS components:  
Hot-plug components  
Hot-plug power supply units (see page 93)  
Hot-plug fans (see page 97)  
Hot-plug HDD modules (see page 100)  
Hot-plug memory boards (see page 115)  
Expansion cards in hot-plug PCIe slots (slots 6 & 7 only, see page 107)  
You can expand or replace the hot-plug components during operation.  
Non-hot-plug components  
Expansion cards in non-hot-plug slots (see page 122)  
These components can be changed by you in the event of an error.  
Expansions and upgrades may only be carried out by authorized specialist  
personnel.  
92  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
CSS components  
Hot-plug components  
8.1  
Hot-plug components  
This section describes how to handle hot-plug components and how to modify  
your server hardware (e.g. adding/replacing hot-plug power supply units).  
The hot-plug procedure increases the availability of system operation and  
guarantees a high degree of data integrity and failsafe performance.  
8.1.1 Hot-plug power supply units  
The server must have at least two hot-plug power supply units (PSUs) to ensure  
redundant power supply. If one power supply unit fails, the other unit ensures  
that the operation can continue uninterrupted. The defective power supply unit  
can be replaced during operation (hot-plug).  
V
CAUTION!  
Areas around the power supply unit may remain extremely hot after  
shutdown. Wait for a while after shutdown before removing the power  
supply unit.  
When installing the power supply unit, be sure to confirm that the  
connector of the PSU is not damaged or bent.  
Do not insert your hands in the power supply unit slot when removing  
the power supply unit. Doing so may cause electric shock.  
If the power supply unit is hard to remove, do not pull out it by force.  
The power supply unit is heavy, so handle it carefully. If you drop it by  
mistake, injuries may result.  
RX600 S5  
Operating Manual  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Hot-plug components  
CSS components  
8.1.1.1 Replacing a hot-plug power supply unit  
0
/
Figure 19: Unlocking and removing the power supply unit  
V
CAUTION!  
When replacing a non-defective hot-plug power supply unit in a non-  
redundant configuration, the server must be switched off first.  
Ê
Remove the power cord from the cable clamp. You can losen the cable  
clamp by opening the small locking lever.  
Ê
Ê
Remove the power cord from the installed power supply unit.  
Press the green release lever (1) and pull out the power supply unit in the  
direction of the arrow (2). Grip the handle while pulling the power supply.  
V
CAUTION!  
Release your hands from lever (1) as soon as the power supply unit  
has been pulled out a few centimeters.  
Ê
Completely remove the defective power supply unit from the slot.  
V
CAUTION!  
Never leave the slot for the power supply unit empty for more than two  
minutes during operation. Otherwise, excessive temperatures could  
damage system components.  
94  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
CSS components  
Hot-plug components  
Ê
Slide the new power supply unit into the empty slot until it clicks into place.  
I
Make sure that the new power supply unit engages correctly in the  
mounting location and is locked in position. This is the only way to  
prevent the power supply unit from sliding out of its mountings and  
being damaged during transportation.  
Ê
Ê
Ê
Thread the cable through the cable clamp (see figure 11 on page 60).  
Pull the cable clamp tight to secure the power cord.  
Connect the newly installed power supply unit to the mains.  
If everything is functioning correctly, the green LEDs 1 and 3 (see "Indicators  
on the hot-plug power supply units" on page 73) at the rear of the power  
supply unit will now light up.  
8.1.1.2 Adding a hot-plug power supply unit  
/
/
0
Figure 20: Removing a PSU dummy module  
Ê
Remove the PSU dummy module as follows:  
1. Press the two metal clips together (see arrows (1) in figure above).  
2. Pull the PSU dummy module out of its slot (see arrow (2) in figure above).  
Ê
Slide the new power supply unit into the empty slot until it clicks into place.  
I
Make sure that the new power supply unit engages correctly in the  
mounting location and is locked in position.This is the only way to prevent  
the power supply unit from sliding out of its mountings and being  
damaged during transportation.  
RX600 S5  
Operating Manual  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
CSS components  
Ê
Ê
Ê
Thread the cable through the cable clamp (see figure 11 on page 60).  
Pull the cable clamp tight to secure the power cord.  
Connect the newly installed power supply unit to the mains.  
If everything is functioning correctly, the green LEDs 1 and 3 (see "Indicators  
on the hot-plug power supply units" on page 73) at the rear of the power  
supply unit will now light up.  
96  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
CSS components  
Hot-plug components  
8.1.2 Hot-plug fans  
The server comes with four hot-plug fans (eight fans only in a redundant  
configuration). Each fan is mounted in a fan module that is accessible from the  
top when opening the server.  
A possible fan failure is reported by the CSS indicator lighting up on the front  
and rear of the server as well as by the indicator on the fan module in question.  
The fan failure is also displayed on the ServerView Local Service Display (see  
the "Customer Self Service (CSS)" manual on the ServerView Suite DVD 2).  
Identifying the defective CSS component  
Ê
Open the server (see "Opening/Closing the server" on page 134).  
The defective fan is identified from the indicator on each fan (see figure 21  
on page 97).  
Figure 21: Indicator on a hot-plug fan  
RX600 S5  
Operating Manual  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Hot-plug components  
CSS components  
8.1.2.1 Replacing a defective fan  
Figure 22: Unlocking a fan module and removing it  
Ê
Press the two green handles and lift the fan module out of the housing (see  
figure 22).  
V
CAUTION!  
Never leave the fan module slot empty for more than two minutes  
during operation. Otherwise, excessive temperatures could damage  
system components.  
Ê
Ê
Insert the new fan module in the empty slot until it clicks into place. To make  
sure the fan has engaged press again.  
The new fan module is tested by Server Management. The LED then either  
does not light at all (fan is ok) or lights up (fan is not ok).  
Close the server (see "Opening/Closing the server" on page 134).  
98  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
CSS components  
8.1.2.2 Adding new fans  
Ê
Ê
Open the server (see "Opening/Closing the server" on page 134).  
Insert the new fan modules in the empty slots until they engage. To make  
sure the fan has engaged press again.  
The new fan module is tested by Server Management. The LED then either  
does not light at all (fan is OK) or lights up (fan is not ok).  
Ê
Close the server (see "Opening/Closing the server" on page 134).  
RX600 S5  
Operating Manual  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
CSS components  
8.1.3 Hot-plug HDD modules  
The hard disk drives which can be ordered for the PRIMERGY RX600 S5 are  
supplied already mounted in an installation frame so that defective hard disk  
drives can be replaced and new hard disk drives can be added during operation.  
The hard disk drive and the installation frame together make up the HDD  
module.  
V
CAUTION!  
The hard disk drive must not be removed from the installation frame  
by anyone except a service technician.  
The HDD modules (drives) must all be marked clearly so that they  
can be put back in their original places after an upgrade. If this is not  
done, existing data can be lost.  
The hot-plug function is only possible in conjunction with a  
corresponding RAID configuration.  
Further information about the RAID configuration or RAID level can  
be found in the RAID controller documentation.  
Do not touch the circuitry on boards or soldered parts. Hold the  
metallic areas or the edges of the circuit boards.  
Before removing the unit, wait for about 30 seconds until the disk  
stops spinning completely.  
When the hard disk unit is starting up, you may hear a resonant noise  
for a while, but this does not mean a failure.  
Depending on the OS, you can configure the write cache settings for  
the hard disk drives. If a power failure should occur while the write  
cache is enabled, cached data may be lost.  
When disposing of, transferring, or returning a hard disk unit, wipe out  
the data on the drive for your own security.  
Rough handling of hard disk units can damage the stored data. To  
cope with any unexpected problems, always back up important data.  
When backing up data to another hard disk drive, you should make  
backups on a file or partition basis.  
Be careful not to hit the hard disk unit or bring it into contact with  
metallic objects.  
Use the device on a shock and vibration free surface.  
100  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
     
CSS components  
Hot-plug components  
Do not use the unit in extremely hot or cold locations, or locations with  
extreme temperature changes.  
Never attempt to disassemble the hard disk unit.  
Handling drives and HDD/SSD modules  
Drives incorporated in the HDD/SSD modules are highly sensitive  
electromagnetic devices and must be handled with great care. Incorrect  
handling can cause partial or total failure of the drives. These failures can result  
in data errors and to a loss of data or to total corruption of the drive.  
Observe the following rules to prevent such problems occurring:  
Only store and transport HDD/SSD modules within the limits stipulated in  
the specification.  
When transporting HDD/SSD modules (even over short distances), always  
use the original packaging (ESD label).  
Never expose HDD/SSD modules to a temperature shock. Avoid the  
formation of condensation inside and on the outside of the drive.  
V
CAUTION!  
The HDD/SSD module must be acclimatized in its operating  
environment for an acclimatization time before it is started up for the  
first time.  
Temperature difference (°C) Minimum acclimatization time  
(operating environment/  
outside)  
(hours)  
5
3
5
10  
15  
7
20  
8
25  
9
30  
10  
Table 5: Acclimatization times for HDD/SSD modules  
Always set the HDD/SSD module down carefully, with the large surface  
facing downwards to prevent it from tipping over.  
RX600 S5  
Operating Manual  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Hot-plug components  
CSS components  
8.1.3.1 HDD/SSD module and dummy module  
/
0
0
1
23 4  
5
Figure 23: 2.5-inch HDD module and dummy module  
1
2
3
4
Dummy module  
Tabs for unlocking the dummy module  
HDD module (installation frame with hard disk drive installed)  
Indicators  
HDD Busy (LED green)  
HDD Fault (LED orange)  
For description see section "Indicators on the hot-plug HDD modules" on  
page 68.  
5
6
7
Handle for locking and unlocking the HDD module  
Button for locking and unlocking the handle  
Ridge for applying a sticker with the current drive name and drive size  
102  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
CSS components  
Hot-plug components  
8.1.3.2 Removing/installing the dummy module  
Free slots are provided with dummy modules. Remove the dummy module  
before installing an additional HDD module.  
1
1
2
Figure 24: Removing/installing the 2.5-inch dummy module  
Ê
Press both tabs on the dummy module together until the locking mechanism  
disengages (1).  
Ê
Pull the dummy module out of the bay (2).  
To install a dummy module, follow the same procedure in reverse order.  
V
CAUTION!  
Store the dummy module in a safe place. If you have removed an HDD  
module and do not install a new one in its place, put the dummy module  
back in its place for cooling, to comply with EMC regulations (regulations  
regarding electromagnetic compatibility), and for protection against fire.  
Ensure that the dummy module engages correctly in the bay.  
RX600 S5  
Operating Manual  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Hot-plug components  
CSS components  
8.1.3.3 Installing the HDD module  
1
2
Figure 25: Unlocking the 2.5-inch HDD module  
Ê
Release the locking mechanism as follows:  
1. Press the two green tabs of the locking lever together (1).  
2. Push the handle of the HDD module fully in the direction of the arrow (2).  
The HDD module is now unlocked.  
104  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
CSS components  
Hot-plug components  
/
0
/
Figure 26: Installing the 2.5-inch HDD module  
Ê
Ê
Carefully push the HDD module into the empty slot (1) until it stops.  
Push the handle completely (2) in the direction of the arrow until the locking  
mechanism engages.  
8.1.3.4 Removing the HDD module  
CAUTION!  
V
Only remove an HDD module during operation if the drive is not  
currently being accessed. Observe the control LEDs for the  
corresponding HDD modules (see "Indicators on the hot-plug HDD  
modules" on page 68).  
Under no circumstances should you remove an HDD module while  
the system is in operation if you are not sure that the hard disk drive  
is operated by a RAID controller and belongs to a disk array that is  
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.  
An HDD module can only be replaced during operation in conjunction  
with a corresponding RAID configuration.  
All HDD modules (drives) must be uniquely identified so that they can  
be reinstalled in their original mounting locations later. If this is not  
done, existing data can be lost.  
If you want to remove an HDD module during operation, proceed as follows:  
RX600 S5  
Operating Manual  
105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hot-plug components  
CSS components  
Ê
Ê
If you want to remove an HDD module that is not defective, the drive must  
be first set to "Offline" via the software (RAID controller configuration  
software).  
Unlock the HDD module as described in section "Installing the HDD module"  
on page 104.  
Ê
Ê
Pull the HDD module out a few centimeters.  
Wait for at least 60 seconds.  
I
This period is necessary for the RAID controller to recognize that an  
HDD module has been removed and for the hard disk drive to come  
to a stop.  
Ê
Ê
Pull the HDD module out completely.  
Install the new HDD module, as described in "Installing the HDD module" on  
page 104.  
V
CAUTION!  
If you have removed an HDD module and do not install a new one in  
its place, put the dummy module back in its place for cooling, to  
comply with EMC regulations (regulations regarding electromagnetic  
compatibility), and for protection against fire. Ensure that the dummy  
module engages correctly in the bay.  
106  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
CSS components  
Hot-plug components  
8.1.4 Hot-plug expansion cards  
V
CAUTION!  
The actions described in this section may only be performed by  
personnel with the appropriate technical training. (The device can be  
are attempted by untrained personnel.)  
Each slot in the server must have either an expansion card or a  
dummy module. A dummy module comprises a retaining plate with an  
attached removal tool.  
information" on page 27.  
The following operations are possible during operation:  
Replacement of expansion cards (see "Removing a hot-plug expansion  
card" on page 109 and "Installing a hot-plug expansion card" on page 113)  
I
Only expansion cards of the same type and with the same settings  
may be exchanged. If the expansion cards do not match, the new  
expansion card will not be commissioned.  
Adding more expansion cards (see "Removing a dummy module" on  
page 112 and "Installing a hot-plug expansion card" on page 113)  
Ê
You should read the accompanying documentation supplied with the  
expansion card beforehand.  
RX600 S5  
Operating Manual  
107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Hot-plug components  
CSS components  
:
9
8
7
6
5
4
3
2
1
0
/
Figure 27: PCI slots with and without hot-plug functionality  
Item  
1
Slot #  
Description  
10  
9
PCIe slot 10  
2
PCIe slot 9  
3
8
PCIe slot 8  
4
7
PCIe slot 7, hot-plug  
PCIe slot 6, hot-plug  
PCIe slot 5  
5
6
6
5
7
4
PCIe slot 4  
8
3
PCIe slot 3  
9
2
PCIe slot 2  
10  
11  
12  
1
PCIe slot 1  
./.  
./.  
Dedicated slot for I/O riser board  
Dedicated slot for SAS controller card  
I
Only slots 6 and 7 are hot-plug slots. These slots are marked with a hot-  
plug label (see arrows in figure 27).  
108  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
CSS components  
Hot-plug components  
8.1.4.1 Identifying the defective CSS component  
Ê
Ê
Open the server (see "Opening/Closing the server" on page 134).  
Press the Indicate CSS button on the system board (see Technical Manual  
for the system board D2870 on the ServerView Suite DVD 2).  
The PRIMERGY Diagnostic LED of the defective CSS component lights up  
orange, thereby indicating which CSS component on the system board must  
be replaced (see Technical Manual for details).  
8.1.4.2 Removing a hot-plug expansion card  
Ê
If required by the operating system, start the PCI hot-plug software. You will  
find information about this in the readme file on the ServerView Suite  
DVD 2).  
0
/
1
Figure 28: Deactivating, unlocking and removing the board  
Ê
Ê
Deactivate the expansion card using either the relevant PCI hot-plug  
software or by pressing the light-pipe switch (1).  
Wait until the light-pipe switch (1) no longer lights up.  
The slot is now zero potential.  
Ê
Ê
If necessary, remove all cables from the expansion card.  
Open the expansion card lock by lifting it up (2).  
RX600 S5  
Operating Manual  
109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Hot-plug components  
CSS components  
The expansion card is now mechanically unlocked.  
Ê
Hold the removal tool by the green handle and pull it out of the PCI slot  
together with the expansion card (3).  
I
Do not pull on the expansion card itself.  
Removing an expansion card from the removal tool  
V
CAUTION!  
When removing the expansion card from the removal tool, pay particular  
attention to the engaging hooks that fasten the board to the removal tool  
(see arrows in figure 29). Do not lift them by more than approx. 1 mm, in  
other words only as far until the expansion card is released. Otherwise  
you could damage the engaging hooks.  
Figure 29: Removing the expansion card from the removal tool  
Ê
Ê
Lift the green movable engaging hooks (see arrows in figure above) no  
more than approx. 1 mm until the expansion card is completely released.  
Take the expansion card out and put it aside.  
110  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
CSS components  
Hot-plug components  
Removing engaging hooks  
/
/
/
0
0
0
Figure 30: Removing engaging hooks from the removal tool  
Ê
Push the green engaging hooks down in the direction of the arrows (1) until  
they disengage from the removal tool.  
Ê
Ê
Remove the engaging hooks (2) and keep them in a safe place.  
To insert a new expansion card, continue with section "Installing a hot-plug  
expansion card" on page 113.  
V
CAUTION!  
If you remove an expansion card and do not insert a replacement, you  
will have to use a dummy module for better cooling, to comply with  
applicable EMC regulations (regulations on electromagnetic  
compatibility) and to protect against fire. Ensure that the dummy module  
engages correctly in the slot.  
RX600 S5  
Operating Manual  
111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Hot-plug components  
CSS components  
8.1.4.3 Removing a dummy module  
If a slot does not contain an expansion card, it is occupied by a dummy module.  
This is a retaining plate with an attached removal tool.  
Before inserting an additional hot-plug expansion card, you will first have to  
remove the dummy module from its slot.  
Ê
Ê
Open the server (see "Opening/Closing the server" on page 134).  
Remove the dummy module in the same way as a PCI board (see figure 29  
on page 110).  
Removing the retaining plate from the removal tool  
V
CAUTION!  
When removing the retraining plate from the removal tool, pay particular  
attention to the engaging hooks that fasten it to the removal tool. Never  
lift the engaging hooks by more than approx. 1 mm, in other words only  
as far until the retaining plate is released. Otherwise you could damage  
the engaging hooks.  
Figure 31: Removing the retaining plate from the removal tool  
Ê
Lift the green engaging hooks (see arrows) no more than approx. 1 mm  
until the retaining plate is released.  
112  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
CSS components  
Hot-plug components  
Ê
Take the retaining plate out and put it aside.  
Keep the retaining plate for future use.  
I
Ê
Push the engaging hooks down until they disengage from the removal tool  
(see figure 30 on page 111), and keep them in a safe place.  
8.1.4.4 Installing a hot-plug expansion card  
Inserting an expansion card in the removal tool  
Figure 32: Inserting the new expansion card in the removal tool  
Ê
Ê
Insert the new expansion card in the provided slot (see oval in figure above)  
of the removal tool.  
Insert the green engaging hooks (see circles in figure 32 on page 113) in the  
rods and push them down until they engage in the upper edge of the  
expansion card.  
V
CAUTION!  
Make sure that e.g. the ports on the expansion card are not blocked  
by the engaging hooks.  
RX600 S5  
Operating Manual  
113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Hot-plug components  
Operating the expansion card  
Ê
Ê
Insert the expansion card fastened to the removal tool in the PCI slot.  
Close the slot lock (see pos. #2 in figure 28 on page 109) by folding it down.  
Make sure that the slot lock engages.  
Ê
Ê
If necessary, connect the cables on the expansion card.  
Activate the expansion card using either the relevant PCI hot-plug software  
or by pressing the light-pipe switch (see pos. #1 in figure 28 on page 109).  
The light-pipe switch flashes green. The slot is in the enable sequence.  
Wait until the light-pipe switch is constantly green.  
The slot is now powered on.  
Ê
Ê
I
If the light-pipe switch continues to flash, an error has occurred.  
Remove the expansion card and repeat the procedure as described  
above.  
Close the server (see "Opening/Closing the server" on page 134).  
114  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
CSS components  
Hot-plug components  
8.1.5 Hot-plug memory boards  
V
CAUTION!  
The actions described in this section may only be performed by  
personnel with the appropriate technical training. (The device can be  
seriously damaged if it is opened without authorization or if repairs  
are attempted by untrained personnel.)  
information" on page 27.  
The system board has space for up to eight memory boards, each of which can  
be equipped with up to eight memory modules. The slots for the main memory  
are suitable for 2 GB, 4 GB, 8 GB and 16 GB DDR3 1066/1333 MHz memory  
modules. This allows a maximum memory capacity of 1024 GB (with availability  
of 16 GB memory modules).  
A possible memory module fault is reported by the CSS indicator lighting up on  
the front and rear of the server or displayed on the ServerView Local Service  
Display (for more information about the behavior of the Local Service Display,  
see chapter "Starting up and operation" on page 63 and the "Customer Self  
Service (CSS)" manual on the ServerView Suite DVD 2).  
RX600 S5  
Operating Manual  
115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Hot-plug components  
CSS components  
8.1.5.1 Identifying the defective memory  
The faulty memory module can be identified from the corresponding DIMM Fault  
LED on the respective memory board (see figure 33) when the server is open.  
Ê
Open the server (see "Opening the server" on page 134).  
/ 012  
3
Figure 33: Button and indicators on memory board  
1
2
3
ATTN button  
4
5
Mirror LED (green)  
ATTN LED (orange)  
Power LED (green)  
8x DIMM Fault LED (orange)  
Ê
Use the DIMM Fault LEDs (5) to identify the faulty memory module.  
The respective DIMM Fault LED lights up orange and indicates the slot on  
the memory board that is occupied by the faulty memory module.  
Ê
Ê
Ê
Ê
Make a note of which LED (e.g. "1B“) on which memory board is lit orange.  
Press the ATTN button (1) .  
Wait until ATTN LED (2) and Power LED (3) are turned off.  
Remove the memory board as described in "Removing the memory board  
in question" on page 117  
116  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
   
CSS components  
Hot-plug components  
8.1.5.2 Removing the memory board in question  
0
0
/
/
Figure 34: Example: Removing memory board  
Ê
Ê
Unlock the memory board in question by pressing the green locks (1). The  
levers on both sides will be released.  
Swivel the levers in an upright position and lift the memory board up and out  
using its levers simultaneously (2).  
8.1.5.3 Removing a defective memory module  
CAUTION!  
V
Please note the equipping rules in the Technical Manual for the  
system board D2870.  
To avoid burning your fingers, wait for a sufficient period of time before  
installing or removing memory modules.  
Do not install unauthorized third party memory modules. Doing so  
may cause electric shock, a fire, or failures.  
Do not insert and remove memory modules repeatedly. Doing so may  
cause failures.  
If the memory module has not been correctly inserted, it may cause  
a fire. Insert the memory module with attention to its direction.  
RX600 S5  
Operating Manual  
117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Hot-plug components  
CSS components  
If a memory module is installed and you pull the lever strongly  
outwards, the memory module pops up. Doing so may cause a device  
failure.  
Please observe the safety information in chapter "Important  
information" on page 27.  
I
To guarantee that all memory modules in the relevant storage mode have  
identical characteristics, you must always replace 4 memory modules  
on each memory board. The only exception is memory boards running  
in spare mode or in independent mode - these only require 2 memory  
modules to be replaced.  
For more information on the individual storage modes, see the Technical  
Manual "System Board D2870 for PRIMERGY RX600 S5".  
0
/
/
Figure 35: Removing a memory module  
Ê
Ê
Press the holders on either side of the memory slot concerned outward (1).  
Pull the defective memory module out of the slot (2).  
118  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
CSS components  
Hot-plug components  
8.1.5.4 Installing a new memory module  
V
CAUTION!  
Observe the safety information concerning memory modules in section  
"Removing a defective memory module" on page 117.  
/
0
0
Figure 36: Installing a memory module  
Ê
Carefully press the memory module into the slot (1) until the fastening tabs  
on both sides of it engage (2).  
8.1.5.5 Reinstalling the memory board in question  
/
0
0
Figure 37: Installing a memory board  
Ê
Ê
Slide the memory board down (1) in the lateral guide channels until it stops.  
Swivel the levers in the direction of the arrows (2).  
Make sure that the green locks on the top engage.  
RX600 S5  
Operating Manual  
119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Hot-plug components  
CSS components  
Ê
Ê
Ê
Press the ATTN button.  
Wait until the ATTN LED is turned off.  
Close the server as described in "Closing the server" on page 136.  
8.1.5.6 Adding a memory board  
To add memory boards during operation, proceed as follows:  
Ê
Ê
Open the server (see "Opening the server" on page 134).  
Remove the air baffle of the respective memory board slot.  
/
0
Figure 38: Removing the memory air baffle to add a memory board  
Ê
Press on the top of the memory air baffle (1), move it in the direction of the  
arrow (2) and out of the housing.  
I
Keep the memory air baffle for future use.  
Ê
Install the equipped memory board into the respective slot.  
I
Memory boards that you insert must suit the fitting rules and the  
appropriate configuration. See the Technical Manual for details.  
Ê
Ê
Ê
Press the ATTN button.  
Wait until the ATTN LED is turned off.  
Close the server as described in "Closing the server" on page 136.  
120  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
CSS components  
Non-hot-plug components  
8.2  
Non-hot-plug components  
V
CAUTION!  
The actions described in this section may only be performed by  
personnel with the appropriate technical training. (The device can be  
seriously damaged if it is opened without authorization or if repairs  
are attempted by untrained personnel.)  
and can be damaged by static electricity. Before handling them, first  
touch a metal part on the server to discharge static electricity from  
your body.  
Do not touch the circuitry on boards and soldered parts. Hold the  
metallic areas or the edge of the circuit boards.  
so may cause injury. It may also cause failures.  
Please observe the safety information in chapter "Important  
If a defective non-hot-plug component is detected (for more information,  
see chapter "Starting up and operation" on page 63 and the "ServerView  
Suite Local Service Concept - LSC" manual on the ServerView Suite  
DVD 2), proceed as follows:  
Ê
Exit all applications and shut down the server properly (see section  
"Switching the server on and off" on page 75).  
Ê
Ê
Pull all power connectors out of the power outlets.  
Remove the server from the rack (see section "Rack  
installation/removal of server" on page 43) and place the server on a  
table, for example.  
RX600 S5  
Operating Manual  
121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Non-hot-plug components  
CSS components  
8.2.1 Identifying the defective CSS component  
Ê
Ê
Open the server (see "Opening/Closing the server" on page 134).  
Press the Indicate CSS button on the system board (see Technical Manual  
for the system board D2870 on the ServerView Suite DVD 2).  
The PRIMERGY Diagnostic LED of the defective CSS component lights up  
orange, thereby indicating which CSS component on the system board must  
be replaced (see Technical Manual for details).  
8.2.2 Replacing a non-hot-plug expansion card  
8.2.2.1 Removing a non-hot-plug expansion card  
Ê
Ê
If necessary, remove all cables from the expansion card.  
Open the expansion card lock by lifting it up (see pos. #2 in figure 28 on  
page 109).  
The expansion card is now mechanically unlocked.  
Ê
Hold the removal tool by the green handle and pull it out of the PCI slot  
together with the expansion card (see pos. #3 in figure 28 on page 109).  
I
Do not pull on the expansion card itself.  
122  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
     
CSS components  
Non-hot-plug components  
Removing an expansion card from the removal tool  
V
CAUTION!  
When removing the expansion card from the removal tool, pay particular  
attention to the engaging hooks that fasten the board to the removal tool  
(see figure 39). Do not lift them by more than approx. 1 mm, in other  
words only as far until the expansion card is released. Otherwise you  
could damage the engaging hooks.  
Figure 39: Removing the expansion card from the removal tool  
Ê
Ê
Lift the green movable engaging hooks (see arrow in figure above) no more  
than approximately 1 mm until the expansion card is completely released.  
Take the expansion card out and put it aside.  
RX600 S5  
Operating Manual  
123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Non-hot-plug components  
Removing engaging hooks  
CSS components  
/
/
/
0
0
0
Figure 40: Removing engaging hooks from the removal tool  
Ê
Push the green engaging hooks down in the direction of the arrow (1) until  
they disengage from the removal tool.  
Ê
Ê
Remove the engaging hooks (2) and keep them in a safe place.  
To insert a new expansion card, continue with section "Installing a hot-plug  
expansion card" on page 113.  
V
CAUTION!  
If you remove an expansion card and do not insert a replacement, you  
will have to use a dummy module for better cooling, to comply with  
applicable EMC regulations (regulations on electromagnetic  
compatibility) and to protect against fire. Ensure that the dummy module  
engages correctly in the slot.  
124  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
CSS components  
Non-hot-plug components  
8.2.2.2 Installing a non-hot-plug expansion card  
Figure 41: Inserting the new expansion card in the removal tool  
Ê
Ê
Insert the new expansion card in the provided slot (see oval in figure above)  
of the removal tool.  
Insert the green engaging hooks (see circles in figure above) in the rods and  
push them down until they engage in the upper edge of the expansion card.  
V
CAUTION!  
Make sure that the ports on the expansion card are not blocked by the  
engaging hooks.  
Ê
Ê
Insert the expansion card fastened to the removal tool in the PCI slot.  
Close the slot lock (see figure 28 on page 109) by folding it down. Make sure  
that the slot lock engages.  
Ê
Ê
If necessary, connect the cables on the expansion card.  
Close the server (see "Opening/Closing the server" on page 134).  
RX600 S5  
Operating Manual  
125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Non-hot-plug components  
CSS components  
8.2.3 Replacing SFP+ transceiver modules  
For Fiber Channel over Ethernet (FCoE) configurations, the ethernet server  
adapter is equipped with one or two SFP+ (small form-factor pluggable)  
transceiver modules.  
In order to remove, install or replace an SFP+ transceiver module, please  
proceed as follows.  
8.2.3.1 Removing an SFP+ transceiver module  
Figure 42: Removing the protective optical port plug  
Ê
If present, remove the protective optical port plug from the SFP+ transceiver  
module.  
V
CAUTION!  
Save the protective port plug for future use.  
126  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
       
CSS components  
Non-hot-plug components  
Figure 43: Unlatching the locking bail  
Ê
Carefully unlatch and fold down the locking bail on the SFP+ transceiver  
module to eject the transceiver from the socket connector.  
RX600 S5  
Operating Manual  
127  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Non-hot-plug components  
CSS components  
Figure 44: Removing the SFP+ transceiver  
Ê
Ê
Pull the SFP+ transceiver module out of its socket connector.  
Reattach the protective optical port plug to the transceiver optical bores.  
I
Place the removed SFP+ transceiver module in an antistatic bag or  
other protective environment.  
128  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
CSS components  
Non-hot-plug components  
8.2.3.2 Installing SFP+ transceiver modules  
Figure 45: Removing the protective optical port plug  
Ê
Ê
Remove the SFP+ transceiver module from its protective packaging.  
Remove the optical port plug from the new / additional SFP+ transceiver  
module.  
V
CAUTION!  
Always keep the protective port plugs attached to the transceiver  
optical bores and fiber-optic cable connectors until you are ready  
to make a connection.  
Save the protective port plug for future use.  
RX600 S5  
Operating Manual  
129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Non-hot-plug components  
CSS components  
Figure 46: Unlatching the locking bail  
Ê
Carefully unlatch and fold down the locking bail on the SFP+ transceiver  
module.  
Figure 47: Inserting the SFP+ transreiver  
Ê
Insert and slide the SFP+ transceiver module into the socket connector as  
far as it will go.  
I
If only one slot is equipped with a SFP+ transceiver module, use the  
primary right connector as shown.  
130  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
CSS components  
Non-hot-plug components  
Figure 48: Latching the locking bail  
Ê
Carefully fold up and latch the locking bail.  
RX600 S5  
Operating Manual  
131  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Non-hot-plug components  
CSS components  
Figure 49: Attaching the protective optical port plug  
Ê
If the SFP+ transceiver module is not immediately connected to an LC  
connector, attach the protective optical port plug to the transceiver optical  
bores.  
132  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
CSS components  
Non-hot-plug components  
Figure 50: Installing the secondary SFP+ transceiver module  
Ê
If applicable, install the secondary SFP+ transceiver module accordingly.  
RX600 S5  
Operating Manual  
133  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Opening/Closing the server  
CSS components  
8.3  
Opening/Closing the server  
V
CAUTION!  
The actions described in this section may only be performed by  
personnel with the appropriate technical training. (The device can be  
seriously damaged if it is opened without authorization or if repairs are  
attempted by untrained personnel.)  
8.3.1 Opening the server  
V
CAUTION!  
The server can be seriously damaged if it is opened without  
authorization or if repairs are attempted by untrained personnel.  
It is essential to observe the safety instructions in chapter "Important  
information" on page 27.  
Before removing or attaching covers, turn off the server, all peripheral  
devices, and any other connected devices. Also unplug all power  
cords from the outlet. Failure to do so can cause electric shock.  
The housing cover must be replaced as soon as possible for  
purposes of cooling, to comply with EMC regulations (regulations  
regarding electromagnetic compatibility) and to prevent fires. The  
housing cover must not remain open for longer than 5 minutes.  
Use the anti-tilt plate to prevent the rack from tipping when installing  
the rack. Pulling the server out of the rack without having installed the  
anti-tilt plate may cause the rack to tip over.  
Be careful not to pinch fingers or clothes when sliding out the server  
or pushing it back. Failure to do so may cause injury.  
134  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
     
CSS components  
Opening/Closing the server  
Figure 51: Opening the server  
Ê
Ê
Loosen the little screw (see circle in figure above) and put it on a safe place.  
Push the two green touchpoints on the cover and move the cover for  
approximately 2 cm backwards.  
Ê
Lift the cover upwards.  
RX600 S5  
Operating Manual  
135  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Opening/Closing the server  
CSS components  
8.3.2 Closing the server  
V
CAUTION!  
The housing cover must be replaced as soon as possible for purposes of  
cooling, to comply with EMC regulations (regulations regarding  
electromagnetic compatibility) and to prevent fires.  
Figure 52: Placing the housing cover  
Place the housing cover onto the server such that it projects approx. 2 cm at  
the back (see circle in figure above).  
Push the housing cover as far as possible in the direction of the arrow.  
Fasten the little screw (see circle in figure 51) on the cover.  
136  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
 
9
Appendix: server specification  
This section explains the specifications for the server. The specifications for this  
server are liable to be updated without any notice. Please be forewarned.  
System Board  
System board type  
Chipset  
D2870  
Intel Xeon 7500 Platform  
Processor  
Processor quantity and 2-4 x Intel Xeon processor 7500 series  
type  
Processor notes  
A mimimum of 2 processors must be configured, no  
mix of different processor types  
Memory Modules Configuration  
Memory slots  
64 (distributed on 8 memory boards with 8 slots  
each)  
Memory slot type  
DIMM (DDR3) registered  
8 GB - 1024 GB  
Memory capacity  
(min. - max.)  
Memory protection  
Advanced ECC, Memory scrubbing, SDDC, Memory  
mirroring support, Hot-spare memory support  
Memory notes  
Memory modules are installed on memory boards  
(8 DIMM slots per memory board). Two memory  
boards are preinstalled in base unit, further memory  
boards as option  
Memory module notes Memory modules will be delivered in sets of 4  
DIMMs per order code.  
Intel 7500 Scalable Memory Buffer supports max.  
1066 MHz memory clock speed.  
1TB memory capacity will be possible with  
availability of 16 GB DIMM modules.  
RX600 S5  
Operating Manual  
137  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix: server specification  
Interfaces  
USB connectors  
Graphics (15-pin)  
Serial (9-pin)  
6 x USB 2.0 (3x front, 2x rear, 1x internal)  
2 x VGA (1x front, 1x rear)  
2 x serial RS-232-C  
LAN / Ethernet (RJ-45) 4 x Gbit/s Ethernet  
Service LAN (RJ45) 1 x dedicated service LAN port for iRMC S2 (10/100  
Mbit/s) Service LAN traffic can be switched to shared  
onboard Gbit LAN port  
Onboard or integrated controllers  
RAID Controller  
8 port RAID 0/1 or RAID 5/6 controller as option  
Remote Management Integrated Remote Management Controller  
Controller  
(iRMC S2, 32 MB attached memory incl. graphics  
controller), IPMI 2.0 compatible  
Trusted Platform  
Module (TPM)  
Infineon / separate module; TCG V1.2 compliant  
(option)  
Slots  
PCI-Express Gen2 x4 3 x full height (2 x 1/2 length, 1 x 3/4 length)  
(mech. x8)  
PCI-Express Gen2 x8 4 x full height (all 3/4 length)  
PCI-Express Gen2 x16 1 x full height (3/4 length)  
PCI-Express x4  
(mech. x8)  
2 x half height (all 1/2 length)  
138  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Appendix: server specification  
Drive bays  
Hard disk bay  
configuration  
8 x 2.5-inch hot-plug SAS  
Accessible drive bays 1 x 5.25/0.5-inch for CD-RW/DVD  
1 x 5.25/1.6-inch for backup devices  
Notes accessible drives all possible options described in relevant system  
configurator  
General system information  
Number of fans  
Fan configuration  
Fan notes  
8
hot-plug  
Different base units available: with 4 fans (non  
redundant) or 8 fans (redundant)  
Operating Panel  
Operating buttons  
On/off switch  
NMI button  
Reset button  
ID button  
Status LEDs  
System status (amber / yellow)  
Identification (blue)  
Hard disks access (green)  
Power (amber / green)  
At system rear side:  
System status (amber / yellow)  
Identification (blue)  
Service display  
(optional):  
ServerView Local Service Display (LSD)  
RX600 S5  
Operating Manual  
139  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix: server specification  
Dimensions / Weight  
Weight  
up to 46 kg  
Weight notes  
Rack mounting kit  
Weight may vary depending on actual configuration  
Rack mounting kit as option (standard for the  
japanese market)  
Dimensions (Base unit specific)  
Rack (W x D x H)  
482.6 mm (Bezel) / 445 mm (Body) x 770 x 176 mm  
Mounting Depth Rack 728 mm  
Height Unit Rack  
19" rackmount  
4 U  
Yes  
Mounting cable depth  
rack  
100 mm (1000 mm rack recommended)  
Environmental  
Noise emission  
Measured according to ISO 7779 and declared  
according to ISO9296  
Sound pressure  
(LpAm)  
46 dB(A) (idle) / 51 dB(A) (operating)  
6.2 B (idle) / 6.6 B (operating)  
at ambient temperature < 23°C  
10 - 35°C  
Sound power (LWAd;  
1B = 10dB)  
Noise notes /  
description  
Operating ambient  
temperature  
Operating relative  
humidity  
10 - 85 % (non condensing)  
Ambient temp. m3/h m3/min  
Exhaust air volume  
<25°C  
30°C  
35°C  
49  
87  
0.82  
1.45  
2.1  
126  
140  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Appendix: server specification  
Electrical values  
Power supply  
configuration  
Up to 4 hot-plug power supplies  
Base unit equipped with 2 power supplies;  
redundancy as option  
Max. output of single  
power supply  
850 W  
Hot-plug power supply  
redundancy  
Yes  
Rated voltage range  
100 - 127 V / 200 - 240 V  
50 - 60 Hz  
Rated frequency range  
Active power min.  
(typical config)  
750 W  
Active power max.  
(typical config)  
1950 W  
Rated active power max. 3360 W (14 A x 240 V)  
Apparent power max.  
(per system unit)  
1990 VA  
Heat emmission  
7020.0 kJ/h = 6653.7 BTU/h  
RX600 S5  
Operating Manual  
141  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix: server specification  
142  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Index  
3rd party rack  
installing in 51  
requirements 44  
USB 54, 63  
controls  
A
accessible drives  
DVD 15, 67  
ID button 64  
reset button 64  
CSS indicator 64, 66, 69  
magnetic tape 15  
acclimatization time 41, 101  
Advanced Video Redirection 18  
ambient conditions 24  
ASR&R 17  
automatic server reconfiguration &  
D
restart 17  
AVR 18  
requirements 43  
date, incorrect 88  
drive  
dummy module  
expansion card 111, 124  
PCI slots 112  
dummy module, HDD module 103,  
106  
B
batteries 31  
BIOS  
security functions 83  
update 20  
C
cables  
connecting 61  
disconnecting 61  
CE marking 23, 35  
chipkill 16  
Class A Compliance Statement 36  
cleaning  
keyboard 81  
monitor 81  
mouse 81  
server 81  
DVD drive 15  
connecting  
indicator 67  
devices 53  
monitor 54  
E
connecting cables 61  
connection panel 53  
connectors  
ECC 16  
EDC 16  
electrical data 22  
RX600 S5  
Operating Manual  
143  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
electromagnetic compatibility 23, 35  
electrostatic-sensitive devices  
(ESD) 34  
EMC directive 23  
EMC regulations 103, 106, 111, 124 hard disk indicators 63  
ENERGY STAR 35  
environment class 24  
environmental protection 39  
error  
HDD module 100  
installation frame 104  
drifting display on monitor 87  
drive “dead” 88  
drive defective 89  
incorrect date 88  
incorrect time 88  
fans 16, 97  
no display on monitor 87  
power-on indicator does not  
light 85  
screen remains blank 86  
screen shows flickering  
stripes 87  
HDD modules 100  
PCI slots 15  
PSUs 93  
server switches itself off 86  
error correcting code 16  
error correction 85  
error detection code 16  
error message on screen 89  
expansion cards 107  
ID card 63, 64  
product name 42, 64  
IME 78  
F
fans 16  
fault  
indicators  
drifting display on monitor 87  
drive defective 89  
incorrect date 88  
incorrect time 88  
no display on monitor 87  
screen remains blank 86  
screen shows flickering  
stripes 87  
DVD drive 67  
global error 64, 67, 70  
hard disk 63  
hard disk activity 64, 66  
HDD busy 68  
HDD fault 68  
ID 64, 66  
FCC statement 36  
operating 66  
operation 64  
optical drive 63  
PSU 73  
G
global error indicator 64, 67, 70  
ServerView Local Service  
Display 67  
144  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
system error 67, 70  
information, additional 13  
installation  
N
connect to mains voltage 55  
connecting devices 53  
connecting monitor 54  
connectors 53  
NMI button 64, 65  
noise level 24  
installation in rack 43  
SFP+ transceiver module 129  
installation overview 25  
installing in  
O
On/Off button 65  
operating system, installing 80  
configuring the server 78  
3rd party rack 51  
DataCenter rack 46  
PRIMECENTER rack 46  
installing in the rack, notes 38  
Integrated Mirroring Enhanced 78  
integrated Remote Management  
Controller 18  
P
iRMC S2 18  
dummy module 112  
L
labels 40  
expansion cards, replacing 107  
LAN connectors 54  
laser information 33  
light emitting diode (LED) 33  
lithium battery 31  
Low Voltage Directive 35  
low voltage directive 23  
power supply unit  
power supply units 16  
prefailure detection and analysis 17  
PRIMECENTER rack  
product name 42, 64  
property protection 83  
PSU  
M
magnetic tape drive 15  
mains voltage 55  
management LAN connector 18  
meaning of the symbols 22  
MegaRAID 78  
memory  
indicators 73  
redundance 93  
hot-spare 16  
memory module  
inserting 119  
removing 117  
memory scrubbing 16  
R
rack  
installing server 43  
removing server 43  
requirements 43  
monitor  
connecting 54  
display drifts 87  
RX600 S5  
Operating Manual  
145  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
RAID controller 15, 17  
RAID controller is not configured for  
this drive 89  
data security 16  
dimensions 24  
RAID level 17  
recycling devices 40  
regulations and standards 23  
Remote Storage 18  
removal  
SFP+ transceiver module 126  
replace  
open 134  
fans 97  
memory boards 115  
PSUs 93  
SFP+ transceiver modules 126  
product name 42  
property protection 83  
serial number 42  
requirements  
3rd party rack 44  
DataCenter rack 43  
PRIMECENTER rack 43  
reset button 64, 65  
return of devices 40  
routing  
switches itself off (error) 86  
transport 37  
cables 49  
S
safety precautions 27  
safety standards 23  
SAS Riser Board, RAID  
controller 15  
ServerView Installation Manager 20,  
SAS riser card 17  
SAS/SATA RAID controller  
configuring 78  
saving energy 39  
screen  
79  
supported functions 19  
ServerView Remote  
Management 21  
service 20  
service LAN connector 18  
SFP+ transceiver module  
installation 129  
removal 126  
start-up  
configuring the server 78  
switching on the server 75  
support 20  
error message 89  
flickering 87  
remains blank 86  
shows flickering stripes 87  
serial connector COM1 54  
serial number 42, 64  
server  
accessible drives 15  
availability 16  
configuration 20, 78  
connectors 53  
146  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  
Index  
support bracket 47  
switch off time, defining 76  
switch on time, defining 76  
switching the server on/off 75  
system board, features 15  
system information 64  
T
target group 11  
technical data 22  
ambient conditions 24  
time, incorrect 88  
tips 85  
transport damage 42  
transporting the server 37  
troubleshooting 85  
U
unpacking, server 42  
USB connector 63  
USB connectors 54  
using cable clamps 60  
V
video connector 63  
voltage 55  
voltage range 16  
RX600 S5  
Operating Manual  
147  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
148  
Download from Www.OSopmearnautainlsg.cMoma.nAullaMlanuals Search And DownloaRdX.600 S5  

Electro Voice Microphone PL91 User Manual
Estate Dishwasher TUD8700SQ User Manual
EverFocus Security Camera EQ610 User Manual
Extron electronic DVD VCR Combo FBI 100 User Manual
Fisher Paykel Ventilation Hood HI120DMB1 User Manual
Fisher Price Motorized Toy Car R8526 User Manual
Flymo Trimmer CT250 User Manual
Focal Car Amplifier Solid 4 User Manual
FoodSaver Food Saver V2860 IUK User Manual
Gefen Switch EXT DVI 841DL User Manual