Fujitsu Server C122 E180 01EN User Manual

FUJITSU Server  
PRIMEQUEST 2000 Series  
REMCS Installation Manual  
C122-E180-01EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Preface  
This manual describes the functions and features of the PRIMEQUEST 2000 series. The manual is intended for system  
administrators.  
For details on the regulatory compliance statements and safety precautions, see the PRIMEQUEST 2000 Series Safety  
and Regulatory Information (C122-E171XA).  
Errata and addenda for the manual  
The PRIMEQUEST 2000 Series Errata and Addenda (C122-E182EN) provides errata and addenda for the manual.  
Read the PRIMEQUEST 2000 Series Errata and Addenda (C122-E182EN) thoroughly in reference to the manual.  
Organization of this manual  
This manual is organized as follows.  
Chapter 1 provides an overview of the REMCS service.  
Chapter 2 describes the connection to the REMCS center, which is required during use of the REMCS service.  
Chapter 3 describes the procedure for starting the REMCS service.  
Chapter 4 describes the operating procedures for the REMCS service.  
Chapter 5 describes the detail settings of the REMCS service.  
Chapter 6 describes the major error messages displayed in the window.  
Chapter 7 describes MMB log collection.  
Chapter 8 describes the notes on using the REMCS GUI.  
C122-E180-01EN  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preface  
Revision History  
Edition  
01  
Date  
Revised location (type) (*1)  
Description  
2014-02-18  
-
-
*1: Chapter, section, and item numbers in the "Revised location" column refer to those in the latest edition of the  
document. However, a number marked with an asterisk (*) denotes a chapter, section, or item in a previous  
edition of the document.  
C122-E180-01EN  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Product operating environment  
This product is a computer intended for use in a computer room environment. For details on the product operating  
environment, see the following manual:  
PRIMEQUEST 2000 Series Hardware Installation Manual (C122-H007EN)  
Safety Precautions  
Alert messages  
This manual uses the following alert messages to prevent users and bystanders from being injured and to prevent  
property damage.  
This indicates a hazardous (potentially dangerous) situation that is likely to result in death or serious  
personal injury if the user does not perform the procedure correctly.  
This indicates a hazardous situation that could result in minor or moderate personal injury if the user  
does not perform the procedure correctly. This also indicates that damage to the product or other  
property may occur if the user does not perform the procedure correctly.  
This indicates information that could help the user use the product more efficiently.  
Alert messages in the text  
An alert statement follows an alert symbol. An alert statement is indented on both ends to distinguish it from regular text.  
Similarly, one space line is inserted before and after the alert statement.  
Only Fujitsu certified service engineers should perform the following tasks on this product and the  
options provided by Fujitsu. Customers must not perform these tasks under any circumstances.  
Otherwise, electric shock, injury, or fire may result.  
-
-
-
-
-
Newly installing or moving equipment  
Removing the front, rear, and side covers  
Installing and removing built-in options  
Connecting and disconnecting external interface cables  
Maintenance (repair and periodic diagnosis and maintenance)  
The List of important alert items table lists important alert items.  
List of important alert items  
This manual does not contain important alert items.  
Warning labels  
Never remove the warning labels.  
C122-E180-01EN  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Warning label location (the main cabinet top)  
C122-E180-01EN  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Warning label location (the main cabinet left)  
Front  
Warning label location (PCI_Box)  
C122-E180-01EN  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Notes on Handling the Product  
About this product  
This product is designed and manufactured for standard applications. Such applications include, but are not limited to,  
general office work, personal and home use, and general industrial use. The product is not intended for applications that  
require extremely high levels of safety to be guaranteed (referred to below as "safety-critical" applications). Use of the  
product for a safety-critical application may present a significant risk of personal injury and/or death. Such applications  
include, but are not limited to, nuclear reactor control, aircraft flight control, air traffic control, mass transit control, medical  
life support, and missile launch control. Customers shall not use the product for a safety-critical application without  
guaranteeing the required level of safety. Customers who plan to use the product in a safety-critical system are requested  
to consult the Fujitsu sales representatives in charge.  
Storage of accessories  
Keep the accessories in a safe place because they are required for server operation.  
Adding optional products  
For stable operation of the PRIMEQUEST 2000 series server, use only a Fujitsu-certified optional product as an added  
option.  
Note that the PRIMEQUEST 2000 series server is not guaranteed to operate with any optional product not certified by  
Fujitsu.  
Maintenance  
Only Fujitsu certified service engineers should perform the following tasks on this product and the  
options provided by Fujitsu. Customers must not perform these tasks under any circumstances.  
Otherwise, electric shock, injury, or fire may result.  
-
-
-
-
-
Newly installing or moving equipment  
Removing the front, rear, and side covers  
Installing and removing built-in options  
Connecting and disconnecting external interface cables  
Maintenance (repair and periodic diagnosis and maintenance)  
Only Fujitsu certified service engineers should perform the following tasks on this product and the  
options provided by Fujitsu. Customers must not perform these tasks under any circumstances.  
Otherwise, product failure may result. PRIMEQUEST 2000 Series General Description  
-
Unpacking an optional Fujitsu product, such as an optional adapter, delivered to the customer  
Modifying or recycling the product  
Modifying this product or recycling a secondhand product by overhauling it without prior approval  
may result in personal injury to users and/or bystanders or damage to the product and/or other  
property.  
Note on erasing data from hard disks when disposing of the product or transferring it  
Disposing of this product or transferring it as is may enable third parties to access the data on the hard disk and use it for  
unforeseen purposes. To prevent the leakage of confidential information and important data, all of the data on the hard  
disk must be erased before disposal or transfer of the product.  
C122-E180-01EN  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
However, it can be difficult to completely erase all of the data from the hard disk. Simply initializing (reformatting) the hard  
disk or deleting files on the operating system is insufficient to erase the data, even though the data appears at a glance to  
have been erased. This type of operation only makes it impossible to access the data from the operating system.  
Malicious third parties can restore this data.  
If you save your confidential information or other important data on the hard disk, you should completely erase the data,  
instead of simply carrying out the aforementioned operation, to prevent the data from being restored. To prevent important  
data on the hard disk from being leaked when the product is disposed of or transferred, you will need to take care to erase  
all the data recorded on the hard disk on your own responsibility.  
Furthermore, if a software license agreement restricts the transfer of the software (operating system and application  
software) on the hard disk in the server or other product to a third party, transferring the product without deleting the  
software from the hard disk may violate the agreement. Adequate verification from this point of view is also necessary.  
Support and service  
Product and service inquiries  
For all product use and technical inquiries, contact the distributor where you purchased your product, or a Fujitsu sales  
representative or systems engineer (SE). If you do not know the appropriate contact address for inquiries about the  
PRIMEQUEST 2000 series, use the Fujitsu contact line.  
Fujitsu contact line  
We accept Web inquiries. For details, visit our website:  
Warranty  
If a component failure occurs during the warranty period, we will repair it free of charge in accordance with the terms of the  
warranty agreement. For details, see the warranty.  
Before requesting a repair  
If a problem occurs with the product, confirm the problem by referring to 11.2 Troubleshooting in the PRIMEQUEST 2000  
Series Administration Manual (C122-E175EN). If the error recurs, contact your sales representative or a field engineer.  
Confirm the model name and serial number shown on the label affixed to the right front of the device and report it. Also  
check any other required items beforehand according to 11.2 Troubleshooting in the PRIMEQUEST 2000 Series  
Administration Manual (C122-E175EN).  
The system settings saved by the customer will be used during maintenance.  
Manual  
How to use this manual  
This manual contains important information about the safe use of this product. Read the manual thoroughly to understand  
the information in it before using this product. Be sure to keep this manual in a safe and convenient location for quick  
reference.  
Fujitsu makes every effort to prevent users and bystanders from being injured and to prevent property damage. Be sure to  
use the product according to the instructions in this manual.  
Manuals for the PRIMEQUEST 2000 series  
The following manuals have been prepared to provide you with the information necessary to use the PRIMEQUEST 2000  
series.  
You can access HTML versions of these manuals at the following sites:  
C122-E180-01EN  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Title  
Description  
Manual code  
C122-E170XA  
PRIMEQUEST 2000 Series Describes what manuals you should read and how to  
Getting Started Guide  
access important information after unpacking the  
PRIMEQUEST 2000 series server. (This manual comes  
with the product.)  
PRIMEQUEST 2000 Series Contains important information required for using the  
C122-E171XA  
Safety and Regulatory  
Information  
PRIMEQUEST 2000 series safely.  
PRIMEQUEST 2000 Series Provides errata and addenda for the PRIMEQUEST 2000 C122-E182EN  
Errata and Addenda series manuals. This manual will be updated as needed.  
PRIMEQUEST 2000 Series Describes the functions and features of the  
C122-B025EN  
General Description  
SPARC Enterprise/  
PRIMEQUEST 2000 series.  
Provides the necessary information and concepts you  
should understand for installation and facility planning for  
C120-H007EN  
PRIMEQUEST Common  
Installation Planning Manual SPARC Enterprise and PRIMEQUEST installations.  
PRIMEQUEST 2000 Series Includes the specifications of and the installation location C122-H007EN  
Hardware Installation Manual requirements for the PRIMEQUEST 2000 series.  
PRIMEQUEST 2000 Series Describes how to set up the PRIMEQUEST 2000 series C122-E174EN  
Installation Manual  
server, including the steps for installation preparation,  
initialization, and software installation.  
PRIMEQUEST 2000 Series Describes how to use the Web-UI and UEFI to assure  
C122-E176EN  
C122-E175EN  
User Interface Operating  
Instructions  
proper operation of the PRIMEQUEST 2000 series  
server.  
PRIMEQUEST 2000 Series Describes how to use tools and software for system  
Administration Manual  
administration and how to maintain the system  
(component replacement and error notification).  
PRIMEQUEST 2000 Series Provides information on operation methods and settings, C122-E177EN  
Tool Reference including details on the MMB, PSA, and UEFI functions.  
PRIMEQUEST 2000 Series Lists the messages that may be displayed when a  
C122-E178EN  
Message Reference  
problem occurs during operation and describes how to  
respond to them.  
PRIMEQUEST 2000 Series Describes REMCS service installation and operation  
C122-E180EN  
REMCS Installation Manual  
PRIMEQUEST 2000 Series Defines the PRIMEQUEST 2000 series related terms and C122-E179EN  
Glossary abbreviations.  
Related manuals  
The following manuals relate to the PRIMEQUEST 2000 series.  
You can access these manuals at the following site:  
http://www.fujitsu.com/global/services/computing/server/primequest/Contact your sales representative for inquiries about  
the ServerView manuals.  
C122-E180-01EN  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Title  
Description  
Manual code  
ServerView Suite ServerView Describes how to install and start ServerView Operations None  
Operations Manager Quick  
Installation (Windows)  
Manager in a Windows environment.  
ServerView Suite ServerView Describes how to install and start ServerView Operations None  
Operations Manager Quick  
Installation (Linux)  
Manager in a Linux environment.  
ServerView Suite ServerView Describes the installation procedure using ServerView  
Installation Manager Installation Manager.  
None  
None  
ServerView Suite ServerView Provides an overview of server monitoring using  
Operations Manager Server ServerView Operations Manager, and describes the user  
Management  
interface of ServerView Operations Manager.  
ServerView Suite ServerView Describes RAID management using ServerView RAID  
None  
RAID Management User  
Manual  
Manager.  
ServerView Suite Basic  
Concepts  
Describes basic concepts about ServerView Suite.  
None  
None  
ServerView Operations  
Manager Installation  
ServerView Agents for Linux  
ServerView Operations  
Manager Installation  
ServerView Agents for  
Windows  
Describes installation and update installation of  
ServerView Linux Agent.  
Describes installation and update installation of  
ServerView Windows Agent.  
None  
None  
ServerView RAID Manager  
VMware vSphere ESXi 5  
Installation Guide  
Describes the installation and settings required to use  
ServerView RAID Manager on the VMware vSphere  
ESXi 5 server.  
MegaRAID SAS Software  
Provides technical information on using array controllers. None  
Refer to the manual from the second DVD for ServerView  
Suite which you can purchase optionally or from the  
following URL:  
The Fujitsu Technology Solutions manuals server  
MegaRAID SAS Device  
Driver Installation  
Provides technical information on using array controllers. None  
Refer to the manual from the second DVD for ServerView  
Suite which you can purchase optionally or from the  
following URL:  
The Fujitsu Technology Solutions manuals server  
C122-E180-01EN  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Title  
Description  
Manual code  
Modular RAID Controller  
Installation Guide  
Provides technical information on using array controllers. None  
Refer to the manual from the second DVD for ServerView  
Suite which you can purchase optionally or from the  
following URL:  
The Fujitsu Technology Solutions manuals server  
Abbreviations  
This manual uses the following product name abbreviations.  
Formal product name  
Microsoft ®Windows Server ® 2012 R2 Datacenter  
Microsoft ®Windows Server ® 2012 R2 Standard  
Microsoft ®Windows Server ® 2012 Datacenter  
Microsoft ®Windows Server ® 2012 Standard  
Microsoft ® Windows Server ® 2008 R2 Standard  
Microsoft ® Windows Server ® 2008 R2 Enterprise  
Microsoft ® Windows Server ® 2008 R2 Datacenter  
Red Hat ® Enterprise Linux ® 6 (for Intel64)  
Oracle Linux 6 (x86_64)  
Abbreviation  
Windows, Windows Server 2012  
Windows, Windows Server 2008  
Linux, RHEL6, RHEL  
Oracle Linux, Oracle Linux 6  
VMware, vSphere 5.x, VMware 5, VMware  
5.x  
VMware vSphere (R) 5  
VMware (R) ESXi (TM) 5  
ESXi, ESXi 5, ESXi 5.x  
SLES11 SP3  
Novell (R) SUSE(R) LINUX Enterprise Server 11 Service Pack 3  
Trademarks  
Microsoft, Windows, and Windows Server are trademarks or registered trademarks of Microsoft Corporation in the United  
States and/or other countries.  
Linux is a registered trademark of Linus Torvalds.  
Red Hat, the Shadowman logo and JBoss are registered trademarks of Red Hat, Inc. in the U.S. and other countries.  
Oracle and Java are registered trademark of Oracle Corporation and its related company.  
Celeron, Celeron Inside, Centrino, Centrino Inside, Core Inside, Intel, the Intel logo, Intel Atom, Intel Atom Inside, Intel Core,  
Intel Inside, the Intel Inside logo, Intel vPro, Itanium, Itanium Inside, Pentium, Pentium Inside, the Rapid Start  
Technology logo, vPro Inside, Ultrabook, Xeon, and Xeon Inside are trademarks or registered trademarks of Intel  
Corporation in the U.S. and other countries.  
Ethernet is a registered trademark of Fuji Xerox Co., Ltd. in Japan and is a registered trademark of Xerox Corp. in the United  
States and other countries.  
VMware is a trademark or registered trademark of VMware, Inc. in the United States and other countries.  
Novell and SUSE Linux Enterprise Server are trademarks of Novell, Inc.  
Xen is a trademark or registered trademark of Citrix Systems, Inc. or its subsidiaries in the United States and other countries.  
Other company names and product names are the trademarks or registered trademarks of their respective owners.  
Trademark indications are omitted for some system and product names in this manual.  
Notation  
C122-E180-01EN  
x
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
This manual uses the following fonts and symbols to express specific types of information.  
Font or symbols  
Meaning  
Example  
See the PRIMEQUEST 2000 Series  
Installation Manual (C122-E174EN).  
Click the [OK] button.  
italics  
Title of a manual that you should refer to  
Window names as well as the names of  
buttons, tabs, and drop-down menus in  
windows are enclosed in brackets.  
[ ]  
Notation for the CLI (command line interface)  
The following notation is used for commands.  
Command syntax  
Command syntax is represented as follows.  
-
-
-
-
Variables requiring the entry of a value are enclosed in angle brackets < >.  
Optional elements are enclosed in brackets [ ].  
Options for optional keywords are grouped in | (stroke) separated lists enclosed in brackets [ ].  
Options for required keywords are grouped in | (stroke) separated lists enclosed in braces { }.  
Command syntax is written in a box.  
Remarks  
The command output shown in the PDF manuals may include line feeds at places where there is no line feed symbol  
(\ at the end of the line).  
Notes on notations  
-
If you have a comment or request regarding this manual, or if you find any part of this manual unclear, please take a  
moment to share it with us by filling in the form at the following webpage, stating your points specifically, and sending  
the form to us:  
The contents of this manual may be revised without prior notice.  
-
-
-
-
-
In this manual, the Management Board and MMB firmware are abbreviated as "MMB."  
In this manual, IOU_10GbE and IOU_1GbE are collectively referred to as IO Units.  
Screenshots contained in this manual may differ from the actual product screen displays.  
The IP addresses, configuration information, and other such information contained in this manual are display  
examples and differ from that for actual operation.  
-
The PDF file of this manual is intended for display using Adobe® Reader® in single page viewing mode at 100%  
zoom.  
This manual shall not be reproduced or copied without the permission of Fujitsu Limited.  
Copyright 2014 FUJITSU LIMITED  
C122-E180-01EN  
xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Contents  
C122-E180-01EN  
xii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
C122-E180-01EN  
xiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Figures  
C122-E180-01EN  
xiv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
C122-E180-01EN  
xv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Tables  
C122-E180-01EN  
xvi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 1 REMCS Service Overview  
1.1 Purpose of REMCS Service  
CHAPTER 1 REMCS Service Overview  
This chapter provides an overview of the REMCS service.  
1.1 Purpose of REMCS Service  
The REMCS service connects your PRIMEQUEST 2000 Series to the REMCS Center, a total support center  
for Fujitsu customers, through the Internet or P-P (point to point) connection to enable the system to send  
server configuration information and automatically report failures when they occur. The REMCS service is  
thus intended to facilitate prompt responses and solutions to problems.  
To receive the REMCS service, you will need a relevant service agreement with Fujitsu. Users without an  
agreement may register with the REMCS Center (registration) but cannot receive the service. For details on  
the service, contact the distributor where you purchased your product or your sales representative.  
1.2 REMCS Linkage Overview  
REMCS Agent reports resource information or problems in a partition to the REMCS Center in linkage with  
theMMB. REMCS Agent reports error information, log information, and other information of the  
PRIMEQUEST 2000 Series system to the REMCS Center via the Internet or P-P (point to point) connection.  
FIGURE 1.1 REMCS linkage  
REMCS Agent of the PRIMEQUEST 2000 Series consists of the MMB firmware and SVS installed in each  
partition. As the REMCS linkage in the figure shows, the MMB firmware monitors the entire system for  
problems, and reports them to the REMCS Center when it detects them. SVS notifies the REMCS Center of  
hardware problem information and hardware configuration information detected by the operating system in  
the partition via the MMB firmware.  
1.2.1 Components implementing the REMCS function  
The REMCS functions of the PRIMEQUEST 2000 Series are implemented by the following components:  
-
MMB  
C122-E180-01EN  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
CHAPTER 1 REMCS Service Overview  
1.2 REMCS Linkage Overview  
Collects hardware configuration information of the entire server, monitors the server for problems, and  
reports thereon to the REMCS Center.  
-
SVS  
Collects configuration information of the PCI cards and SCSI devices recognized in the partition and  
monitors them for problems.  
Configuration information monitoring  
Detects changes in the hardware or software configuration, and reports the latest configuration information to  
the REMCS Center.  
Problem notification  
When a hardware problem occurs in a server, automatically notifies the REMCS Center of the problem and  
sends problem information including logs to the REMCS Center.  
Whenever an event involving a hardware problem occurs in the same unit after the REMCS Center has been  
notified of the hardware problem, notification thereon to the REMCS Center is suppressed. Events detected  
by SVS are cleared when the operating system is rebooted or when SVS is stopped or restarted. When a  
problem with a notification level that is higher than that of an event for which notification is being suppressed  
occurs in the same part, problem notification takes place even within the notification suppression period. At  
this time, the notification suppression time is cleared to 0, and the notification suppression continues. For  
SVS, there is no processing related to notification suppression time. Accordingly, until a problem with a high  
notification level occurs or until the events are cleared, notification of abnormalities is suppressed.  
Periodic connection  
Automatically connects to the REMCS Center at specified times to confirm the existence of the  
communication path and REMCS Agent  
1.2.2 Installing the REMCS function  
The REMCS function of the PRIMEQUEST 2000 Series consists of the MMB and SVS installed on the  
partition side.  
Installation in the MMB  
The MMB REMCS function is installed as standard. The function does not need to be installed.  
Installation in SVS  
For details on the procedure for installing the function in SVS, see 5.2 Setting of SVS (SVagent) in the  
PRIMEQUEST 2000 Series Installation Manual (C122-E174EN).  
1.2.3 Connection configurations supported by the REMCS function  
The PRIMEQUEST 2000 Series supports only the connection configurations shown below. Each of these  
connection configurations uses only SMTP for communication with the REMCS Center.  
-
Internet connection (e-mail)  
With this connection configuration, communication with the REMCS Center is executed via the Internet.  
P-P connection (ISDN: e-mail)  
-
With this connection configuration, communication with the REMCS Center is executed with a P-P  
system using a line such an ISDN line.  
C122-E180-01EN  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 2 Before Using the REMCS Service  
2.1 Overview of Connection to the REMCS Center  
CHAPTER 2 Before Using the REMCS  
Service  
This chapter describes the connection to the REMCS center, which is required during use of the REMCS  
service.  
2.1 Overview of Connection to the REMCS Center  
The connection configuration for connecting to the REMCS Center depends on the network configuration  
and server configuration of the user. The connection configuration to be used must be determined  
beforehand.  
The PRIMEQUEST 2000 Series supports the following connection configurations. All of these connection  
configurations use only SMTP to communicate with the REMCS Center.  
-
-
Internet connection (e-mail)  
P-P connection (ISDN: e-mail)  
Field engineers make the setting for connecting to the REMCS Center.  
2.2 Connection Configuration for Connecting to the REMCS  
Center  
This section explains the connection configurations for connecting to the REMCS Center.  
The following connection configurations are available.  
-
-
2.2.1 Internet connection (e-mail)  
This connection configuration is used for communication with the REMCS Center via the Internet.  
Using a network connected to the user port  
uses a network connected to the user port.  
Remarks  
If the SMTP server at the customer site is specified with the FQDN, the DNS to be referred to by the MMB  
must be set. If the SMTP server is specified with the IP address, this setting is not required.  
C122-E180-01EN  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 2 Before Using the REMCS Service  
2.2 Connection Configuration for Connecting to the REMCS Center  
FIGURE 2.1 Internet connection (using the network connected to the user port)  
Using a network not connected to the user port  
FIGURE 2.2 Internet connection (using REMCS port) shows a configuration that uses the REMCS port to  
connect to a network other than that connected to the user port. The SMTP server of an ISP (Internet Service  
Provider) cannot be specified.  
Remarks  
-
-
The IP address of [Maintenance Port] must be set from the Web-UI of the MMB.  
Be sure to specify the SMTP server with the IP address.  
FIGURE 2.2 Internet connection (using REMCS port)  
2.2.2 P-P connection (ISDN: e-mail)  
Use a P-P system using a line such as an ISDN line for communication with the REMCS Center.  
Through the network connected to a USER port  
configuration that uses the network connected to a USER port.  
C122-E180-01EN  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 2 Before Using the REMCS Service  
2.2 Connection Configuration for Connecting to the REMCS Center  
FIGURE 2.3 P-P connection (ISDN: e-mail) (using the network connected to a USER port)  
Through a network that is not connected to a USER port  
REMCS port to connect to a network other than the network connected to a USER port.  
There are two types of configuration: one has the REMCS port connected directly to the ISDN router, and  
the other has the HUB (router) connected to configure a dedicated LAN with other units and to connect the  
ISDN router to the HUB  
Remarks  
-
-
The IP address for [MaintenancePort] must be set from the MMB Web-UI. However, DNS cannot be  
specified.  
Be sure to use the IP address to specify the SMTP server.  
FIGURE 2.4 P-P connection (ISDN: e-mail) (using the REMCS port)  
C122-E180-01EN  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.1 Start Procedure Overview  
CHAPTER 3 REMCS Service Start  
Procedure  
This chapter describes the procedure for starting the REMCS service.  
3.1 Start Procedure Overview  
To start the REMCS service, the user must register with the REMCS Center (registration).  
Registration means to register customer information with the REMCS Center.  
This procedure can be omitted if a field engineer has already completed the registration procedure on behalf  
of the customer, using the information obtained directly from the customer during product installation.  
FIGURE 3.1 REMCS Center registration flow shows the screen transitions during the initialization work.  
C122-E180-01EN  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.1 Start Procedure Overview  
FIGURE 3.1 REMCS Center registration flow  
Before registration, prepare the following information.  
- Warranty (contains your machine model name, check code, and serial number)  
The warranty is used to confirm that the machine ID displayed at the bottom of the REMCS window  
is correct.  
Example display format: machine ID 00-PQ1000-model name-check code-serial number.  
-
IP address or FQDN of the mail server to be used  
C122-E180-01EN  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
You can specify the FQDN only when using an Internet connection through the user port.  
If you specify an FQDN, confirm that a DNS server is specified in [Network] - [Network Interface] of the  
MMB Web-UI.  
-
-
-
Sender e-mail address (with permission to send external e-mails)  
Whether to enable the mail server for partitioned e-mail sending  
Confirm whether your mail server is enabled for partitioned e-mail sending.  
To connect to the REMCS Center through the REMCS port, you first need to set the Maintenance Port in  
[Network] - [Network Interface] of the MMB Web-GUI. Before making the port settings, prepare such  
information as the IP address to be assigned, subnet mask, gateway address, and destination SMTP  
server address.  
You can also set the IP address of the REMCS port by using the following CLI.  
Set command: Sets the REMCS port.  
set maintenance_ip <ip address> <netmask> <gateway address>  
<SMTPaddress>  
Note  
You do not need to specify <gateway address> and <SMTP address> if you make point-to-point (P-P)  
REMCS connections. In this case, specify 0.0.0.0 for both <gateway address> and <SMTP address>.  
Display command: Displays the REMCS port settings.  
show maintenance_ip  
For details on the commands, see Chapter 2 MMB CLI (Command Line Interface) Operations in the  
PRIMEQUEST 2000 Series Tool Reference (C122-E177EN).  
Note  
Do not perform registration during the maintenance work.  
3.2 REMCS Center Registration  
This section describes how to register with the REMCS Center.  
Use the following registration procedure.  
-
-
-
-
-
-
-
3.2.1 Starting REMCS  
To start REMCS, select the [Maintenance] - [REMCS] - [REMCS] menu in the MMB Web-UI.  
If no registration has been made so far, the window shown in FIGURE 3.2 [Customer Information Registration  
If the registration has already been made, the window shown in FIGURE 3.2 [Customer Information  
Registration Instructions] window does not appear. Instead, the window shown in FIGURE 4.1 [REMCS initial]  
window appears.  
For details on the procedure, see CHAPTER 4 REMCS Service Operations  
C122-E180-01EN  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
FIGURE 3.2 [Customer Information Registration Instructions] window  
1. Click the [Next] button.  
The window for selecting the REMCS Center to connect to appears.  
3.2.2 Setting the connection configuration  
Select the REMCS Center to connect to in the window shown in FIGURE 3.3 [Selecting REMCS Center]  
The REMCS Center you connect to differs according to the installation country. The initial value for Japan is  
usually [OSC]. Thus, simply confirm the value in this window.  
If you have already confirmed the value, this window does not appear.  
C122-E180-01EN  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
FIGURE 3.3 [Selecting REMCS Center] window  
1. Click the [Next] button.  
The REMCS Center to connect to is registered. Then, the [Initial Settings] window for setting up the  
environment appears.  
3.2.3 Setting up the environment  
Set up the environment from FIGURE 3.4 [Initial Settings] window. Specify the connection configuration you  
You can also set up the environment by importing the setting information (environment information such as  
the SMTP server address and sender e-mail address as well as customer information such as the customer  
name and administrator's e-mail address) of another machine or the setting information that was backed up  
and saved in your machine.  
After setting the REMCS service, you can still change the connection type by clicking [Initial Settings] from the  
menu in the window shown in FIGURE 4.1 [REMCS initial] window.  
C122-E180-01EN  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
FIGURE 3.4 [Initial Settings] window  
Newly setting up the environment  
The procedure for newly setting up the environment is as follows.  
1. Select the connection configuration from the following.  
-
-
-
Internet Connection(Mail Only): The initial setting for the connection configuration  
P-P Connection(ISDN: Mail Only): Connection via ISDN  
P-P Connection(VPN: Mail Only): Connection via VPN  
2. Click the [Next] button.  
After the connection configuration is registered, the corresponding setting window appears.  
The following procedure is for cases where the environment information already exists.  
If the following setting information exists in another machine or was previously backed up and saved in your  
machine, you can perform automatic registration by importing the information.  
-
-
Customer information: rm_bkcus.def  
Environment information: rm_bkenv.def  
For details on the procedure when the environment information is already available, see 3.2.6 Confirming the  
When the connection type is [Internet Connection(Mail Only)]  
If you selected [Internet Connection(Mail Only)] in the window shown in FIGURE 3.4 [Initial Settings] window,  
the window shown in FIGURE 3.5 [Internet(Mail Only) connection environment settings] window appears.  
Specify the information for sending e-mail via the Internet.  
After setting the REMCS service, you can still change the connection configuration by clicking [Initial  
Settings] from the menu in the window shown in FIGURE 4.1 [REMCS initial] window.  
C122-E180-01EN  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
FIGURE 3.5 [Internet(Mail Only) connection environment settings] window  
1. Enter the values for the following items.  
TABLE 3.1 Input items for the [Internet(Mail Only) connection environment settings] window  
Item  
Description  
SMTP Server  
Enter the SMTP server name or IP address in single-byte  
alphanumeric characters and symbols.  
Sender E-mail Address  
Authentication type  
AUTH SMTP type  
Enter the sender e-mail address in single-byte alphanumeric  
characters and symbols.  
Select the authentication type from [No certification], [POP Before  
STMP], and [AUTH STMP].  
Valid if you specified the authentication type [AUTH SMTP].You can  
select from [AUTO (initial value)], [CRAM-MD5], [PLAIN], and  
[LOGIN].  
UserID  
Enter the user ID for the authentication server in single-byte  
alphanumeric characters and symbols.  
Password  
POP Server  
Enter the password for the authentication server in single-byte  
alphanumeric characters and symbols.  
If you specified the authentication type [POP Before STMP], enter  
the POP server name or  
IP address in single-byte alphanumeric characters and symbols.  
Select the division method from [No division], [Mail division], and  
[Event division].  
Division method  
The initial value at new installation is [Event division]. The initial  
value at the firmware update time is the setting before the firmware  
update.  
Division Size  
Enter the partitioning size in the range of 10 to 100 Kbytes. The  
initial value is 64 Kbytes.  
Encryption type  
If the S/MIME format is not supported before the firmware update,  
the initial value is [Previous encryption]. The initial value at the  
firmware update time is the setting before the firmware update.  
2. Click the [Next] button.  
After the connection configuration is registered, the window shown in FIGURE 3.7 [Periodical  
C122-E180-01EN  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
When the connection configuration is [P-P Connection(ISDN: Mail Only)] or [P-P  
Connection(VPN:Mail Only)]  
If you selected [P-P Connection(ISDN: Mail Only)] or [P-P Connection(VPN: Mail Only)] in the window shown  
After setting the REMCS service, you can still change the connection information by clicking [Connection  
Environment] from the menu in the window shown in FIGURE 4.1 [REMCS initial] window.  
FIGURE 3.6 [Point-to-Point Connection environment settings] window  
1. Enter the values for the following items.  
TABLE 3.2 Input items for the [Point-to-Point Connection environment settings] window  
Item  
Description  
SMTP/PROXY Server  
Enter the SMTP/PROXY server name or IP address in single-byte  
alphanumeric characters and symbols.  
Sender E-mail Address  
Division method  
Division Size  
Enter the sender e-mail address in single-byte alphanumeric  
characters and symbols.  
Select the division method from [No division], [Mail division], and  
[Event division]. The initial value is [Event division].  
Enter the partitioning size in the range of 10 to 100 Kbytes. The  
initial value is 64 Kbytes.  
Encryption type  
If the S/MIME format is not supported before the firmware update,  
the initial value is [Previous encryption]. The initial value at the  
firmware update time is the setting before the firmware update.  
2. Click the [Next] button.  
After the connection configuration is registered, the window shown in FIGURE 3.7 [Periodical  
3.2.4 Setting the periodic connection schedule  
In the window shown in FIGURE 3.7 [Periodical Connection settings] window, specify the periodic  
connection schedule.  
After starting the REMCS service, you can still change the periodic connection schedule by clicking  
[Periodical Connection] from the menu in the window shown in FIGURE 4.1 [REMCS initial] window.  
C122-E180-01EN  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
FIGURE 3.7 [Periodical Connection settings] window  
1. Specify the values for the following items.  
TABLE 3.3 Input items for the [Periodical Connection settings] window  
Item  
current schedule of  
Periodic Connection  
Period  
Description  
The initial values are [Every week] and [10:00] to [15:00]. Specify  
values if you need to change the setting.  
Specify the setting from [Every day], [Every day (excluding Sunday)],  
[Every day (excluding Saturday & Sunday)], and [Every week].  
If you specified [Every week] for the period, you need to specify a day  
of the week (Sunday to Saturday).  
A day of the week  
2. Click the [Next] button.  
After the periodic connection schedule is registered, the customer information window appears. Proceed  
3.2.5 Setting the customer information  
Enter the customer information in the window shown in FIGURE 3.8 [Customer Information] window.  
After starting the REMCS service, you can still change the customer information by clicking [Customer  
Information update] from the menu in the window shown in FIGURE 4.1 [REMCS initial] window.  
C122-E180-01EN  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
FIGURE 3.8 [Customer Information] window  
You can use the following characters and symbols for input.  
-
E-mail addresses must include, but cannot begin or end with, an @ mark. Also, the character that follows  
the @ mark must not be a dot (.).  
-
E-mail addresses must not use the following symbols: ( ) < > ; : [ ] \.  
The input items and values for the customer information are as follows.  
TABLE 3.4 Input items for the [Customer Information] window  
Input item  
Maximum  
number of  
characters  
30  
Input  
Personal  
information  
(*1)  
Description  
Company  
Name  
Department/  
Division  
Required  
Optional  
N/A  
Enter the company name.  
20  
N/A  
Enter your department/division name.  
Address  
Administrator  
Name  
30  
20  
Required  
Required  
N/A  
Applicable  
Enter the address.  
Enter the server administrator name.  
Administrator  
Email Address  
60  
Required  
Applicable  
Enter the server administrator's e-mail  
address in single-byte alphanumeric  
characters and symbols.  
E-mail notifications of completed  
registration or error occurrences are sent  
to this e-mail address.  
Zip/Postal  
Code  
(*2)  
Optional  
N/A  
Enter the zip/postal code for your  
company address in single-byte numeric  
characters and '-'.  
Phone  
Number  
FAX Number  
20  
20  
32  
Required  
Optional  
Optional  
Applicable  
Applicable  
N/A  
Enter the phone number in single-byte  
numeric characters/symbols and '-'.  
Enter the FAX number in single-byte  
numeric characters/symbols and '-'.  
Enter the unique name at your site in  
single-byte alphanumeric characters and  
symbols.  
Machine  
Unique Name  
Country  
2
Required  
N/A  
Enter the installation country in alphabetic  
characters ("JP" for Japan; lower case  
characters are converted to upper case  
C122-E180-01EN  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
characters).  
Specify the country name with the code in  
the A2 column of ISO-3166 Code Table  
(two letters). For a country not specified in  
the table, specify 99.  
Machine  
Installation  
Site  
Machine  
Installation  
Building  
FE's E-mail  
Address  
30  
20  
60  
Optional  
Optional  
Optional  
N/A  
Enter the machine installation site (not  
required if it is the same as the [Address]  
value).  
Enter the machine installation building  
name (not required if it is the same as the  
[Address] value).  
Enter the e-mail address of the installer  
(field engineer). E-mail notification of  
completion of the connection check is  
also sent to this email address.  
Specify whether personal information  
should be deleted. If checked, the values  
entered for the items for which the  
[Personal information] column in this table  
indicates [Applicable] are not retained as  
customer information for the MMB.  
Checked: The values are deleted.  
Not checked: The values are not deleted  
(default).  
N/A  
Applicable  
Delete the  
personal  
information  
Check box  
Optional  
N/A  
*1: Considered personal information to be protected. If the personal information is deleted from the window  
shown in FIGURE 5.7 [Deleting the personal information] window by the FE, the information is deleted  
from the MMB customer information.  
*2: The number of characters in the zip/postal code depends on the country in which the PRIMEQUEST  
2000 Series server is installed.  
1. Enter the customer information.  
2. Click the [Next] button.  
After the customer information is registered, the window shown in FIGURE 3.9 [Customer Information  
Review] window appears.  
FIGURE 3.9 [Customer Information Review] window  
3. Click the [Next] button.  
C122-E180-01EN  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
After the customer information is registered, the window shown in FIGURE 3.10 [Information Transmit  
This window also appears when you click the [Auto Setting] button in the window for restoring setting  
information to perform automatic setting.  
FIGURE 3.10 [Information Transmit Agreement] window  
4. Confirm the agreement and click the [Agree] button.  
After the customer information is registered, the window shown in FIGURE 3.11 [Registration result]  
window appears.  
3.2.6 Confirming the registration result  
When the registration is completed, the execution result is displayed in the window shown in FIGURE 3.11  
C122-E180-01EN  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.2 REMCS Center Registration  
FIGURE 3.11 [Registration result] window  
1. Click the [Next] button to proceed to 3.2.7 Checking the connection.  
3.2.7 Checking the connection  
1. The window shown in FIGURE 3.12 [Connection check] window appears. Confirm the setting of the e-  
mail addresses that receive the result of the connection check.  
FIGURE 3.12 [Connection check] window  
-
Notification of the result to the administrator:  
Specify whether to report the result to the administrator. If the personal information is not deleted, the  
administrator's e-mail address you entered during the customer information setting is displayed.  
C122-E180-01EN  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 3 REMCS Service Start Procedure  
3.3 Importing the Registration Information  
-
Notification of the result to the installer:  
Specify whether to report the result to the installer. If you select notification, set the installer's e-mail  
address in [E-mail address for receiving results].  
2. Click the [Check] button to perform the connection check and display the window in FIGURE 3.13  
FIGURE 3.13 [Result of connection check] window  
3. Click the [OK] button.  
After the connection check is completed, the window in FIGURE 4.1 [REMCS initial] window appears.  
3.3 Importing the Registration Information  
The window shown in FIGURE 3.14 [Importation of the REMCS settings] window appears when you click  
[Import from the local files] in the window shown in FIGURE 3.4 [Initial Settings] window. It imports the  
specified setting information files (the environment information file and customer information file) and  
performs automatic setting.  
You can use the setting information files backed up in the same or different machine.  
C122-E180-01EN  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.3 Importing the Registration Information  
FIGURE 3.14 [Importation of the REMCS settings] window  
1. In the PC or file server running the Web browser, specify the following files that were previously backed  
up and saved.  
-
-
Environment information file: Browse an rm_bkenv.def file.  
Customer information file: Browse an rm_bkcus.def file.  
2. Click the [Import] button to import the settings information files.  
3. Click the [Automatic registration] button.  
window appears. After you specify the operation, the window shown in FIGURE 3.16 [Connection check  
information] window appears. Confirm the setting of the receivers of the connection result.  
Note that if you click the [Delete] button in the window shown in FIGURE 3.15 [After automatic  
registration, do you delete the personal information] window, personal information is deleted after the  
automatic registration is completed.  
FIGURE 3.15 [After automatic registration, do you delete the personal information] window  
C122-E180-01EN  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.3 Importing the Registration Information  
FIGURE 3.16 [Connection check information] window  
-
-
Notification of the result to the administrator  
Specify whether to report the result to the administrator. The administrator e-mail address in the  
imported customer information is displayed as your administrator e-mail address.  
Notification of the result to the installer  
Specify whether to report the result to the installer. If you select notification, set the installer's e-mail  
address in [E-mail address for receiving results].  
4. Click the [Next] button to set automatic registration.  
appears.  
FIGURE 3.17 [Information Transmit Agreement] (for automatic setting) window  
5. Confirm the agreement and click the [Agree] button.  
After the customer information is registered, the window shown in FIGURE 3.18 [Automatic registration  
state] window appears.  
C122-E180-01EN  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3 REMCS Service Start Procedure  
3.4 Replacing the S/MIME certificate during the initialization work  
FIGURE 3.18 [Automatic registration state] window  
6. Click the [OK] button.  
After the registration is completed, the window shown in FIGURE 4.1 [REMCS initial] window appears.  
3.4 Replacing the S/MIME certificate during the initialization  
work  
This section describes the procedure for replacing the certificate.  
1. Click [Replacement of certificates] from FIGURE 3.4 [Initial Settings] window to display FIGURE 3.19  
FIGURE 3.19 [Replacement of certificates] window (during initialization work)  
2. Specify the certificate file and then click the [Next] button. FIGURE 3.20 [Confirmation of certificate]  
C122-E180-01EN  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 3 REMCS Service Start Procedure  
3.4 Replacing the S/MIME certificate during the initialization work  
FIGURE 3.20 [Confirmation of certificate] window (during initialization work)  
3. Click the [Next] button to output the following confirmation message.  
"The certificates will be replaced. Once the replacement of certificates proceeds, the report to the  
REMCS center will not be done until connected confirmation is completed. Are you sure?"  
4. Click the [OK] button to return to FIGURE 3.4 [Initial Settings] window.  
C122-E180-01EN  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 4 REMCS Service Operations  
4.1 REMCS Operations Overview  
CHAPTER 4 REMCS Service Operations  
This chapter describes how to operate the REMCS service.  
4.1 REMCS Operations Overview  
When the REMCS Center registration is completed or cancelled, the window shown in FIGURE 4.1 [REMCS  
initial] window appears. This window also appears when you start REMCS through the MMB Web-UI after  
the confirmation of connection to the REMCS Center is completed.  
Select the function to perform from the menu on the left side of the window shown in FIGURE 4.1 [REMCS  
TABLE 4.1 Items in the REMCS initial window shows the menu items in the REMCS initial window.  
FIGURE 4.1 [REMCS initial] window  
TABLE 4.1 Items in the REMCS initial window  
Item  
Description  
Re-register  
Updates the registration information.  
Customer Information  
update  
Confirms or changes the customer information.  
Displays or changes the connection information.  
Specifies or changes the periodic connection schedule.  
Exports the setting information.  
Specifies or changes the connection configuration.  
Displays the certificate used for transmission in S/MIME format.  
Replaces the certificate used for transmission in S/MIME format.  
Connection Environment  
Periodical Connection  
Export Settings  
Connection type change  
Display of certificate  
Replacement of  
certificates  
Replacement to the  
previous certificate  
Replaces the certificate used for transmission in S/MIME format with  
the one used earlier.  
If a certificate has not been replaced, this item cannot be selected.  
Connection check  
Checks the connection to the REMCS Center.  
Temporary Disconnection Temporarily disconnects the system from the REMCS Center for cases  
such as maintenance.  
Reconnection  
Re-establishes the connection to the REMCS Center after temporary  
disconnection.  
HW Config. Info.  
HW Config. Info.  
Exit  
Sends the hardware configuration information.  
Sends the software configuration information.  
Exits the REMCS operations and closes the browser window.  
C122-E180-01EN  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
4.2 REMCS Service Menu  
This section describes the REMCS service menu items.  
4.2.1 Customer Information update  
Use this menu item to confirm the customer information entered on registration or to change the information  
such as the administrator name or company address.  
The procedure for displaying and confirming the customer information is as follows.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Customer Information  
update].  
The [Customer Information] window appears.  
2. If your purpose is confirmation only, click the [Cancel] button. If you want to update the information,  
change the relevant value and click the [Next] button.  
The [Customer Information Review] window appears.  
3. Confirm the information. If everything is correct, click the [Next] button. The FIGURE 3.10 [Information  
Transmit Agreement] window appears. If you find any wrong information and need to correct it, click the  
[Back] button to return to the [Customer Information Review] window.  
4. After confirming that your environment is enabled for sending e-mails, click the [Agree] button. The  
entered information is automatically sent to the REMCS Center. When the e-mail transfer is completed,  
the [Registration result] window appears.  
5. Click the [Next] button to return to the initial window.  
-
The administrator's e-mail address entered in the [Customer Information] window receives an e-mail  
notification of completed registration.  
-
Any updates to the user registration information before receiving the e-mail notification should be  
invalid. Be sure to update the information after receiving the e-mail notification of completed  
registration.  
4.2.2 Re-register  
You can use this menu item only when you have not yet registered customer information after updating it in  
the [Customer Information] window.  
The procedure for re-registration is as follows.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Re-register].The  
2.  
3.  
After confirming that your environment is enabled for sending e-mails, click the [Agree] button. The  
entered information is automatically sent to the REMCS Center. When the e-mail transfer is completed,  
the [Registration result] window appears.  
Click the [Next] button to return to the window shown in FIGURE 4.1 [REMCS initial] window.  
-
The administrator's e-mail address entered in the [Customer Information] window receives an e-mail  
notification of completed registration.  
-
Any updates to the user registration information before receiving the e-mail notification should be  
invalid. Be sure to update the information after receiving the e-mail notification of completed  
registration.  
4.2.3 Connection Environment  
Use this menu item to display the current connection information or to change the setting information such  
as the mail server setting.  
The procedure for displaying and confirming the connection information is as follows.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Connection Environment].  
-
If your environment is set for Internet Connection(Mail Only), the window shown in FIGURE 4.2  
-
If your environment is set for other connection types,the window shown in FIGURE 4.3 [Point-to-Point  
Connection environment settings] window appears. For details on how to operate the windows, see  
C122-E180-01EN  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.2 [Internet (Mail Only) connection environment settings] window  
FIGURE 4.3 [Point-to-Point Connection environment settings] window  
2.  
Confirm the information. If you want to correct or change the information, click the [Next] button. After the  
information is updated, the browser returns to the window shown in FIGURE 4.1 [REMCS initial] window.  
If your purpose is confirmation only, click the [Cancel] button to return to the window in FIGURE 4.1  
4.2.4 Periodical Connection  
Use this menu item to display or change the periodic connection schedule.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Periodical  
Connection].The window shown in FIGURE 4.4 [Periodical Connection settings] window appears. For  
details on how to operate the windows, see CHAPTER 3 REMCS Service Start Procedure.  
C122-E180-01EN  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.4 [Periodical Connection settings] window  
2.  
After changing the periodic connection schedule, click the [Next] button. A connection check is  
performed to report the schedule to the REMCS Center. When the processing completes, you will be  
If your purpose is confirmation only, click the [Cancel] button. You will be returned to FIGURE 4.1  
The administrator's e-mail address entered in the [Customer Information] window receives an e-mail  
notification of completed connection check.  
4.2.5 Export Settings  
Use this menu item to save the customer information and environment setting information to local files.  
The exported setting information can be used in different servers to start the REMCS service regardless of  
the operating system.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Export Settings].The  
2. Click [Environment information] or [Customer Information].  
The dialog box for specifying the file name and the file store location. Specify the following files.  
-
-
Customer information: rm_bkcus.def  
Environment information: rm_bkenv.def  
3. Click the [Cancel] button to return to the window shown in FIGURE 4.1 [REMCS initial] window.  
C122-E180-01EN  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.5 [Exportation of the REMCS settings] window  
C122-E180-01EN  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
4.2.6 Connection type change  
Use this menu item to change the current connection configuration to another configuration.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Connection type  
change].  
The [Connection type change] window (shown in FIGURE 4.6 Window for changing the active  
2. After changing the connection configuration, click the [Next] button. The current setting information is  
discarded and the machine status becomes [Setting not completed].  
You need to perform the service start procedure by specifying the connection information again  
FIGURE 4.6 Window for changing the active connection configuration  
4.2.7 Displaying the certificate  
Use the following procedure to confirm the information of the certificate.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Display of certificate].  
The window will appear according to following cases:  
-
-
-
-
Window displayed when the certificate has not been replaced  
C122-E180-01EN  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.7 [Display of certificate] window (with certificate not replaced)  
-
Certificate display when the certificate has been displayed (certificate in use)  
Select [Certificate under use] and then click the [Display] button.  
FIGURE 4.8 [Display of certificate] window (during use of certificate that has been replaced)  
-
Certificate display for certificate that has been replaced (previous certificate)  
Select [The previous certificate] and then click the [Display] button.  
C122-E180-01EN  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.9 [Display of certificate] window (Certificate that has been displayed – previous certificate)  
2. To confirm and exit, click the [End] button. Click the [End] button to return to the window shown in  
4.2.8 Replacing the certificate  
Use the following procedure to replace the certificate you are currently using, with another certificate.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Replacement of  
certificates].  
The window shown in FIGURE 4.10 [Replacement of certificates] window appears.  
FIGURE 4.10 [Replacement of certificates] window  
C122-E180-01EN  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
2. Specify the certificate file and then click the [Next] button.  
FIGURE 4.11 [Confirmation of certificate] window  
3. Confirm the display contents and, if they are acceptable, click the [Next] button.  
If you do not intend to replace a certificate, click the [Cancel] button.  
4. The following confirmation message is displayed."The certificates will be replaced. Once the replacement  
of certificates proceeds, the report to the REMCS center will not be done until connected confirmation is  
completed. Are you sure?"  
If this is acceptable, click the [OK] button.  
5. The machine status display becomes [UNUSED] and the [Connection check] window appears. Upon  
confirmation, [ACTIVE] becomes effective.  
4.2.9 Restoring a certificate  
Use the following procedure to return to the previous certificate from the replacement certificate.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Replacement to the  
previous certificate].  
FIGURE 4.12 [Replacement to the previous certificate] window  
C122-E180-01EN  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
2. Confirm the content of the <<Restored certificate>> and then click the [Next] button.  
If you do not wish to restore the certificate, click the [Cancel] button.  
3. The following confirmation message appears. "The certificates will be replaced. Once the replacement of  
certificates proceeds, the report to the REMCS center will not be done until connected confirmation is  
completed. Are you sure?" If this is acceptable, click the [OK] button.  
4. The machine status becomes [UNUSED], and the [Connection check] window appears. Upon  
confirmation, [ACTIVE] becomes effective.  
4.2.10 Connection check  
Use this menu item to check the connection to the REMCS Center.  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click the [Connection check]  
button.  
The [Connection check] window (the window shown in FIGURE 4.13 [Connection check] window (without  
deleted) appears.  
2. Confirm the setting of the receivers of the connection results and click the [Check] button.  
FIGURE 4.13 [Connection check] window (without personal information deleted)  
C122-E180-01EN  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.14 [Connection check] window (with personal information deleted)  
3. The window shown in FIGURE 4.15 [Result of connection check] window appears. Click the [OK] button.  
You will be returned to the window shown in FIGURE 4.1 [REMCS initial] window.  
C122-E180-01EN  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.15 [Result of connection check] window  
The e-mail addresses displayed in the [Connection check] window as the receivers of the connection results  
receive an e-mail notification of the completed connection check.  
4.2.11 Temporary Disconnection  
Use this menu item to temporarily disconnect from the REMCS Center.  
-
-
-
It disconnects the server from the REMCS Center when the server is stopped for maintenance or  
holidays and cannot establish periodic connections.  
While being disconnected from the REMCS Center, the system does not communicate with the REMCS  
Center at all.  
To restart the system operation after being disconnected from the REMCS Center, you need to perform  
[Reconnection].  
1. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Temporary  
Disconnection].  
2. Click the [Disconnect] button. A confirmation dialog box appears and a notification of the temporary  
disconnection is sent to the REMCS Center.  
After processing completes, a pop-up window appears with the results.  
Then, the window shown in FIGURE 4.1 [REMCS initial] window appears.  
C122-E180-01EN  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.16 [Temporary Disconnection] window  
4.2.12 Reconnection  
Use this menu item to re-establish the connection with the REMCS Center after a temporary disconnection.  
If the server operating status has been shown as [DISCONNECT], it becomes [ACTIVE].  
1. If the status has been in [MAINTAIN/DISCONNECT], it becomes [MAINTAIN].  
From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Reconnection] to  
display the window shown in FIGURE 4.17 [Reconnection] window.  
2. Click the [Reconnect] button. A confirmation dialog box appears.  
Send the notification of reconnection to the REMCS Center.  
After processing completes, a pop-up window appears with the results.  
Then, the window shown in FIGURE 4.1 [REMCS initial] window appears.  
C122-E180-01EN  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
FIGURE 4.17 [Reconnection] window  
4.2.13 HW Config. Info.  
Use this menu item to send the hardware configuration information of the server to the REMCS Center.  
From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [HW Config. Info.] to  
1. Click the [Send] button.  
A confirmation dialog box appears. Send the hardware configuration information to the REMCS  
Center.After processing completes, a pop-up window appears with the results. Then, the window shown  
FIGURE 4.18 [Sending Hardware Configuration Information] window  
4.2.14 SW Config. Info.  
Use this menu item to send the software configuration information of the server to the REMCS Center.  
From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [SW Config. Info.] to  
C122-E180-01EN  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 4 REMCS Service Operations  
4.2 REMCS Service Menu  
1. Click the [Send] button.  
A confirmation dialog box appears. Send the software configuration information to the REMCS Center.  
After processing completes, a pop-up window appears with the results. Then, the window shown in  
FIGURE 4.19 [Sending Software Configuration Information] window  
Remarks  
It may take some time before the software configuration information of the partition takes effect. Therefore,  
the latest information may not be displayed immediately after the software replacement.  
C122-E180-01EN  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings  
5.1 Overview of REMCS Service Detail Settings  
CHAPTER 5 CHAPTER 5 REMCS Service  
Detail Settings  
This chapter describes the detail settings of the REMCS service.  
5.1 Overview of REMCS Service Detail Settings  
REMCS Service Detail Settings are used to make detailed settings such as the transmission retry count and  
timeout triggers for avoiding transmission problems. They are also used to change the REMCS Center to  
connect to, switch the machine name to be displayed, and for other purposes.  
Normally, these settings need not be used. Use them when so instructed by a field engineer or the support  
center.  
To start the window to be used for the REMCS service detail settings, select [Maintenance] - [REMCS] -  
[Detail Setup] from the MMB Web-UI.  
The initial window shown in FIGURE 5.1 FE operation initial window appears.  
FIGURE 5.1 FE operation initial window  
TABLE 5.1 Items of the FE operation initial window  
Item  
Description  
Detail environment settings  
Change the timeout triggers, the retry count, etc., that are applicable  
when the Internet is used.  
Selecting REMCS Center  
Select language  
Machine name display  
change  
Changes the REMCS Center to connect to.  
Switches the displayed language between Japanese and English.  
Specifies whether to use the machine ID or a unique name as the  
machine name displayed by the Web-GUI.  
Deleting the personal  
information  
Deletes the personal information included in the customer  
information.  
Display of SSL Certificate  
SSL certificate acquired by SMTP server will be displayed when  
sending is done on SMTPoverSSL (*1). If SSL certificate does not  
exist, following message will appear:  
“ RMG_0229: TBD ”  
*1: When STARTTLS or SSL/TLS is selected as type of encryption  
connection on [Environment settings] window  
C122-E180-01EN  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings  
5.2 Detail Environment Settings  
5.2 Detail Environment Settings  
This item is used to change the communication environment settings for Internet use.  
The displayed window contents depend on the authentication type of the connection configuration as shown  
Take adequate care when making the setting. Otherwise it may become impossible to send events to the  
REMCS Center if an incorrect setting is made.  
FIGURE 5.2 [Environment settings] window in case of internet connection (only mail)  
TABLE 5.2 Items in the [Environment settings] window in case of internet connection (only mail)  
Input item  
Maximum  
number of  
digits  
Input  
Description  
E-Mail settings  
Timeout  
4
Required  
Enter the timeout trigger for E-Mail (seconds)  
in single-byte numeric characters.  
Range: 60 to 3600  
Retry Count  
2
3
Required  
Required  
Enter the retry count for E-Mail in single-byte  
numeric characters.  
Enter the retry interval for E-Mail in single-  
byte numeric characters.  
Retry interval  
Range: 1 to 600  
SMTP server  
PORT No.  
128  
5
Required  
Required  
Enter the name of SMTP server or IP  
address in single-byte numeric character and  
alphabets  
Enter the port number of the SMTP server in  
single-byte numeric characters.  
Initial value: 25 (Well Known Port is used.)  
Range: 1 to 65535  
Type of encrypted  
connection  
-
Required  
Select type of encrypted connection of SMTP  
over SSL from ‘None’ (default), ‘STARTTLS’  
and ‘SSL/TLS’  
Authentication settings  
Authentication type  
-
-
Required  
Required  
Select authentication type from ‘None’,  
‘AUTO’ (default), ‘POP before SMTP’, ‘AUTH  
SMTP’.  
Select SMTP authentication from ‘Auto’  
(default), ‘CRAM-MD5’, ‘PLAIN’, ‘LOGIN’.  
AUTH SMTP type  
(This entry is valid at  
setting [Authentication  
type] in [AUTH  
SMTP])  
C122-E180-01EN  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings  
5.2 Detail Environment Settings  
User ID  
64  
64  
Required (*1) Enter user ID of authentication server in  
single-byte numeric number and alphabets.  
Required (*1) Enter password of authentication server in  
single-byte numeric number and alphabets.  
Password  
Entered values are all displayed as *.  
POP settings (When you specify [POP Before SMTP] for [Authentication type])  
POP server  
128  
Required (*2) Enter the name of POP server or IP address  
in single-byte numeric number and  
alphabets.  
Port No.  
5
Required  
Enter the port number of the POP3  
authentication server in single-byte numeric  
characters.  
Initial value: 110 (Well Known Port is used.)  
Range: 1 to 65535  
wait time after POP  
authentication  
4
Required  
Enter the wait time from POP3 authentication  
to the start of mail sending (milliseconds) in  
single-byte numeric characters.  
Recommended value: 1000 ms  
Range: 0 to 30000  
Connection control  
IP version priority  
-
Required  
Required  
Required  
Select the priority of IP version from ‘none’,  
‘IPv4 (default)’ and ‘IPv6’  
Others  
Sender E-mail  
Address  
128  
Enter the e-mail address of originator in  
single-byte numeric characters and  
alphabets.  
Select dividing method from ‘none’, ‘event  
dividing’ (default).  
Large data  
transmission method  
-
Split size  
3
Required (*3) Enter dividing size in single-byte numeric  
characters.  
- mail  
Default: 64 KB  
Range: 10 to 100 KB  
- event  
Default: 512 KB  
Range: 64 to 512 KB  
*1: It is required if you select item except for ‘None’ in authentication type.  
*2: It is required if you select item except for ‘POP Before SMTP’ in authentication type.  
*3: It is required if you select item except for ‘None’ in dividing method.  
C122-E180-01EN  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings  
5.2 Detail Environment Settings  
FIGURE 5.3 [Environment settings] window in case of P-P connection  
TABLE 5.3 Items in the [Environment settings] window in case of P-P connection  
Input item  
Maximum  
number of  
digits  
Input  
Description  
E-Mail settings  
Timeout  
4
Required  
Enter the timeout trigger for E-Mail (seconds)  
in single-byte numeric characters.  
Range: 60 to 3600  
Retry Count  
2
3
Required  
Required  
Enter the retry count for E-Mail in single-byte  
numeric characters.  
Enter the retry interval for E-Mail in single-  
byte numeric characters.  
Retry interval  
Range: 1 to 600  
SMTP/PROXY server 128  
Required  
Required  
Enter the name of SMTP/PROXY server or  
IP address in single-byte numeric character  
and alphabets  
Enter the port number of the SMTP server in  
single-byte numeric characters.  
Initial value: 25 (Well Known Port is used.)  
Range: 1 to 65535  
Select type of encrypted connection of SMTP  
over SSL from ‘none’ (default), ‘STARTTLS’  
and ‘SSL/TLS’  
PORT No.  
5
-
Type of encrypted  
connection  
Required  
Connection control  
IP version priority  
-
Required  
Required  
Required  
Select the priority of IP version from ‘none’,  
‘IPv4 (default)’ and ‘IPv6’  
Others  
Sender E-Mail  
Address  
128  
Enter the e-mail address of originator in  
single-byte numeric characters and  
alphabets.  
Select dividing method from ‘none’, ‘event  
dividing’ (default).  
Large data  
transmission method  
-
Split size  
3
Required (*1) Enter dividing size in single-byte numeric  
characters.  
- mail  
Default: 64 KB  
Range: 10 to 100 KB  
- event  
Default: 512 KB  
Range: 64 to 512 KB  
C122-E180-01EN  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings  
5.3 Selecting REMCS Center  
*1: It is required if you select item except for ‘none’ in dividing method.  
1. From the initial window menu of the FE operation, select [Detail environment settings].  
Depending on the current setting conditions, FIGURE 5.2 [Environment settings] window in case of  
appears.  
2. Click the [Setting] button.  
When a confirmation dialog box appears, register the setting.  
After the processing , the result is displayed in a pop-up window, and the initial window is displayed  
again.  
During operation, maintenance or stopping connection, [Confirming connection] window will appear.  
5.3 Selecting REMCS Center  
This item is used to change the REMCS Center to connect to.  
1. From the initial window menu of the FE operation, select [Selecting REMCS Center] to display FIGURE  
2. Select the REMCS center to connect to. It cannot be input directly. Select one from the provided list of  
REMCS Centers. The initial value is the current center name.  
3. Click the [Setting] button. A confirmation dialog box appears. Register the setting.  
After the processing, the result is reported in a pop-up window, and the initial window is displayed again.  
FIGURE 5.4 [Selecting REMCS Center] window  
5.4 Select Language  
This item is used for switching the displayed language between Japanese and English.  
1. From the initial window menu of the FE operation, select [Select language] to display FIGURE 5.5 [Select  
2. Select [Japanese] or [English]. The initial value is the current setting value.  
3. Click the [Setting] button.  
When a confirmation dialog box appears, register the setting.  
After the processing, the result is reported in a pop-up window, and the initial window is displayed again.  
C122-E180-01EN  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings  
5.5 Machine Name Display Change  
FIGURE 5.5 [Select language (Japanese or English)] window  
5.5 Machine Name Display Change  
This item is used for switching the machine name to be displayed by the GUI between the machine ID or  
machine unique name, which has been specified in the [Customer Information] window.  
1. From the initial window menu of the FE operation, select [Machine name display change] to display  
2. Specify the machine name to be displayed in the state display frame. The initial value is the current  
setting value.  
3. Click the [Setting] button.  
When a confirmation dialog box appears, register the setting.  
After the processing, the result is reported in a pop-up window, and the initial window is displayed again.  
C122-E180-01EN  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings  
5.6 Deleting the Personal Information  
FIGURE 5.6 [Select to Display Machine ID or Machine Unique Name] window  
5.6 Deleting the Personal Information  
This item is used for deleting the personal information included in the customer information after registration.  
1. From the initial window menu of the FE operation, select [Deleting the personal information] to display  
2. When the [Delete] button is clicked, a confirmation dialog box appears. After the processing, the result is  
reported in a pop-up window.  
FIGURE 5.7 [Deleting the personal information] window  
5.7 Display of certificate  
This item is used for displaying and confirming SSL certificate.  
C122-E180-01EN  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings  
5.7 Display of certificate  
1. From the initial window menu of the FE operation, select [Display of certificate] to display エラー! 参照元  
が見つかりません。.  
2. Click [End] button.  
FIGURE 5.8 [Display of certificate] window (SSL)  
C122-E180-01EN  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
CHAPTER 6 REMCS Messages  
This chapter describes the major error messages that are displayed in the windows.  
6.1 Messages in REMCS Windows  
This section describes the messages displayed in the REMCS windows.  
In the messages, xxx represents a character string such as a returned value that should be replaced when  
printed out.  
TABLE 6.1 Messages common to all windows  
Message code  
RMG_0150  
RMG_1121  
Message  
Failed to read setting file. (xxx)  
This session was disconnected.(xxx)  
Action  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
If operations need to be  
performed in the REMCS  
window, restart the REMCS  
window.  
RMG_1123  
RMG_1125  
RMG_1135  
This session was disconnected.  
Session timeout.  
This session was disconnected.  
TABLE 6.2 Messages at GUI startup  
Message code  
RMG_0001  
RMG_0002  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Failed to get Machine ID..(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Proceed with registration.  
RMG_0007  
RMG_0012  
RMG_0018  
RMG_0041  
RMG_0164  
RMG_0165  
Change language to English.  
Failed to get registration data..(xxx)  
Failed to setting Machine status.(xxx)  
Failed to change language to Japanese.(xxx)  
Failed to change language to English.(xxx)  
RMG_0166  
RMG_0167  
RMG_0172  
Change language to Japanese completed.  
Changing language to English completed.  
Failed to get Destination information. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0188  
RMG_0193  
The setting file error was detected and  
initialized it.  
The REMCS frame is not displayed, because  
the  
Perform registration.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
REMCS module is not available.  
window and try again. If the  
problem is not solved,  
contact the support center.  
TABLE 6.3 Messages in the menu frame  
Message code  
RMG_0001  
RMG_0002  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
RMG_0004  
C122-E180-01EN  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
problem is not solved,  
contact the support center.  
None.  
RMG_0005  
RMG_0006  
Frame data make completed.  
Failed to get connect mode. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Click the [OK] or [Cancel]  
button.  
RMG_0035  
REMCS menu close. Are you sure?  
TABLE 6.4 Messages in the state display frame  
Message code  
RMG_0001  
RMG_0002  
RMG_0004  
RMG_0006  
RMG_0065  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data.(xxx)  
Invalid CGI parameter specified.  
Failed to get connect mode. (xxx)  
Failed to get customer information.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
TABLE 6.5 Messages in the setting progress display window  
Message code  
RMG_0001  
RMG_0002  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data.(xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Click the [OK] or [Cancel]  
button.  
RMG_0004  
RMG_0035  
REMCS menu close. Are you sure?  
TABLE 6.6 Messages in the [Customer Information] window  
Message code  
RMG_0002  
RMG_0004  
Message  
Action  
Failed to make frame screen data.(xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0010  
RMG_0018  
Customer Information Registration frame  
display completed.  
Failed to get registration data..(xxx)  
If the error still occurs when  
you  
retry the operation, exit and  
restart the REMCS window  
and  
try again. If the problem is  
not  
solved, contact the support  
center.  
TABLE 6.7 Messages in the initial window  
Message code  
RMG_0002  
RMG_0004  
Message  
Action  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0008  
Initial frame display completed.  
C122-E180-01EN  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
TABLE 6.8 Messages in the [Initial Settings] window  
Message  
Message code  
Action  
RMG_0001  
RMG_0002  
RMG_0004  
RMG_0006  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Failed to get connect mode. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0011  
RMG_0025  
Initial Settings frame display completed.  
Failed to set connection mode. (xxx)  
RMG_0026  
RMG_0027  
Changed connection mode to xxx.  
Failed to change Machine status. (xxx)  
TABLE 6.9 Messages in the [Importation of the REMCS settings] window  
Message code  
RMG_0002  
RMG_0004  
Message  
Action  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Correct the entered value.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Specify a valid file.  
RMG_0015  
RMG_0027  
Invalid entry.  
Failed to change Machine status. (xxx)  
RMG_0032  
RMG_0033  
The specified file can not be imported.  
Invalid directory name specified.  
Specify a valid directory  
name.  
RMG_0036  
RMG_0096  
Required entry.  
The specified file includes an unsupported  
Enter a valid value.  
Specify a file with the same  
connection type. The environment information connection type.  
cannot be imported.  
RMG_0118  
Failed to import the environment information  
and the customer information.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0142  
The file doesn't exist in the selected directory. Specify the directory in  
which the file is located.  
RMG_0143  
RMG_0144  
RMG_0194  
Invalid REMCS environment information file.  
Invalid customer information file.  
Automatic registration failed, because there  
was no required entry in the Customer  
information file.  
Specify a valid file and try  
again.  
Check the customer  
information file contents,  
correct the error, and then  
try again.  
RMG_0196  
Failed to delete personal information.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
C122-E180-01EN  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
problem is not solved,  
contact the support center.  
None.  
RMG_0210  
Personal information deletion frame display  
has been completed.  
TABLE 6.10 Messages in the [Customer Information Review] window  
Message code  
RMG_0002  
RMG_0004  
Message  
Action  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Failed to read setting file.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0150  
RMG_0215  
This certificate cannot be verified up to a CA  
certificate.  
TABLE 6.11 Messages in the [Automatic registration state] window  
Message code  
Message  
Action  
RMG_0002  
RMG_0004  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0038  
RMG_0039  
RMG_0040  
Automatic registration started.  
Automatic registration completed.  
Automatic registration failed. (xxx:xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
TABLE 6.12 Messages in the [Internet (Mail Only) connection environment settings] window  
Message code  
RMG_0001  
RMG_0002  
RMG_0004  
RMG_0006  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data.(xxx)  
Invalid CGI parameter specified  
Failed to get connect mode. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0015  
RMG_0016  
RMG_0018  
Invalid entry.  
Input value is out of range.  
Failed to get registration data (xxx)  
Correct the entered value.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Correct the specified POP  
server information.  
RMG_0030  
RMG_0031  
Specify [UserID]/[Password]/[POP Server] all  
when you specify POP server.  
Specify [UserID]/[Password] all when you  
specify AUTH SMTP.  
Correct the specified AUTH  
SMTP information.  
RMG_0036  
RMG_0037  
Required entry.  
Execute registration of REMCS environment  
data.  
Enter a valid value.  
Click the [OK] or [Cancel]  
button.  
Are you sure?  
RMG_0041  
Failed to setting Machine status.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
C122-E180-01EN  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
RMG_0042  
RMG_0043  
Internet(Mail Only) connection environment  
None.  
setting frame display completed.  
Failed to set REMCS environment (Internet  
connection(Mail only)). (xxx)  
Confirm the FQDN or IP  
address of the specified  
SMTP server.  
Also check whether the  
network status is normal.  
None.  
RMG_0044  
RMG_0056  
RMG_0095  
Registration of REMCS environment data  
(Internet connection(Mail only)) completed.  
Failed in the connection check notification.  
(xxx)  
Check whether the network  
status is normal.  
Connection type mismatch.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Enter a valid value.  
RMG_0181  
RMG_0189  
Invalid E-mail address specified.  
Execute registration of REMCS environment  
data.After this operation, all events are not  
sent to the REMCS Center until connection  
check is completed.  
Click the [OK] or [Cancel]  
button.  
\nAre you sure?  
RMG_0207  
RMG_0208  
Invalid value in [Split size].Please specify it  
within the range of 10-100.  
Invalid value in [Split size].Please specify it  
within the range of 64-512.  
Enter a valid value.  
TABLE 6.13 Messages in the [Point-to-Point Connection environment settings] window  
Message code  
RMG_0001  
RMG_0002  
RMG_0004  
RMG_0006  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Failed to get connect mode. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Correct the entered value.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Fill in any blank entries.  
Click the [OK] or [Cancel]  
button.  
RMG_0015  
RMG_0018  
Invalid entry.  
Failed to get registration data.(xxx)  
RMG_0028  
RMG_0037  
Input all entries.  
Execute registration of REMCS environment  
data.  
Are you sure?  
RMG_0041  
Failed to setting Machine status.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Check whether the network  
status is normal.  
RMG_0056  
RMG_0079  
RMG_0080  
Failed in the connection check notification.  
(xxx)  
Point-to-Point Connection environment setting None.  
frame display completed.  
Failed to set REMCS environment(Point-to-  
Point).(xxx)  
Confirm the FQDN or IP  
address of the specified  
SMTP server.  
Also check whether the  
network status is normal.  
None.  
RMG_0081  
Registration of REMCS environment data  
(Point-to-Point) completed.  
C122-E180-01EN  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
RMG_0095  
Connection type mismatch.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Enter a valid value.  
RMG_0181  
RMG_0189  
Invalid E-mail address specified.  
Execute registration of REMCS environment  
data.After this operation, all events are not  
sent to the REMCS Center until connection  
check is completed.  
Click the [OK] or [Cancel]  
button.  
\nAre you sure?  
RMG_0207  
RMG_0208  
Invalid value in [Split size].Please specify it  
within the range of 10-100.  
Invalid value in [Split size].Please specify it  
within the  
Enter a valid value.  
range of 64-512.  
TABLE 6.14 Messages in the [Periodical Connection settings] window  
Message code  
RMG_0001  
RMG_0002  
RMG_0004  
RMG_0006  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Failed to get connect mode. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0015  
RMG_0016  
RMG_0018  
RMG_0027  
Invalid entry.  
Correct the entered value.  
Input value is out of range.  
Failed to get registration data.(xxx)  
Failed to change Machine status. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Enter a valid value.  
Confirm the start time and  
set a valid end time.  
Click the [OK] or [Cancel]  
button.  
RMG_0036  
RMG_0048  
Required entry.  
Invalid end time.  
RMG_0049  
RMG_0050  
RMG_0051  
RMG_0052  
Execute registration of periodical connection  
schedule. Are you sure?  
Periodical Connection setting frame display  
completed.  
Failed to register the periodical connection  
schedule. (xxx)  
Failed to set the periodical connection  
schedule. (xxx)  
None.  
Check whether the network  
status is normal.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0054  
Registration of the periodical connection  
schedule  
completed.  
RMG_0056  
RMG_0186  
RMG_0187  
Failed in the connection check  
notification.(xxx)  
Failed to send notice of changing agent  
information.  
Check whether the network  
status is normal.  
Failed to send agent information.  
TABLE 6.15 Messages in the [Customer Information] window  
Message  
Message code  
RMG_0001  
RMG_0002  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
RMG_0004  
C122-E180-01EN  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
RMG_0006  
Failed to get connect mode. (xxx)  
window and try again. If the  
problem is not solved,  
contact the support center.  
Correct the entered value.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Enter a valid length.  
RMG_0015  
RMG_0018  
Invalid entry.  
Failed to get registration data. (xxx)  
RMG_0029  
RMG_0036  
RMG_0065  
Invalid length.  
Required entry.  
Failed to get customer information.(xxx)  
Enter a valid value.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0066  
RMG_0068  
RMG_0069  
Customer Information setting frame display  
completed.  
Invalid character specified in [Company  
Name].  
Invalid character specified in  
[Department/Division].  
Confirm the valid characters  
and correct the entry.  
RMG_0070  
RMG_0071  
RMG_0072  
Invalid character specified in [Address].  
Invalid character specified in [Building].  
Invalid character specified in [Administrator  
Name].  
RMG_0073  
RMG_0074  
RMG_0075  
Invalid character specified in [Machine  
Installation Site]  
Invalid character specified in [Machine  
Installation Building].  
Characters that cannot be specified are  
included in the [Company Name(kana)] of  
customer information.  
RMG_0076  
RMG_0181  
Characters that cannot be specified are  
included in the [Administrator Name(kana)] of  
customer information.  
Invalid E-mail address specified.  
Enter a valid value.  
TABLE 6.16 Message in the [Customer Information Review] window  
Message code  
RMG_0001  
RMG_0002  
RMG_0004  
RMG_0041  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Failed to setting Machine status.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0067  
RMG_0077  
Customer Information frame display  
completed.  
Failed to register customer information. (xxx)  
Confirm that HOSTNAME is  
specified in the MMB  
Network Interface setting. If  
the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0078  
Customer information registration completed.  
TABLE 6.17 Message in the [Information Transmit Agreement] window  
Message code Message Action  
C122-E180-01EN  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
RMG_0001  
RMG_0002  
RMG_0004  
RMG_0006  
RMG_0041  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Failed to get connect mode. (xxx)  
Failed to setting Machine status.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Check whether the network  
status is normal.  
RMG_0056  
Failed in the connection check notification.  
(xxx)  
RMG_0082  
RMG_0083  
RMG_0084  
Registration started.  
None.  
Update registration started.  
Agreement of sending information frame  
display completed.  
RMG_0085  
Registration failed. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0086  
RMG_0088  
Executed registration.  
Update registration failed.(xxx)  
RMG_0089  
RMG_0128  
Executed update registration.  
Execute registration.  
TABLE 6.18 Messages in the [Registration result] window  
Message code  
RMG_0001  
RMG_0002  
Message  
Action  
Failed to get Machine status.(xxx)  
Failed to make frame screen data.(xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0004  
RMG_0082  
RMG_0083  
RMG_0085  
Registration started. None.  
Update registration started.  
Registration failed.(xxx)  
Check whether the network  
status is normal.  
None.  
RMG_0086  
RMG_0087  
RMG_0088  
Executed registration.  
Registration result frame display completed.  
Update registration failed.(xxx)  
Check whether the network  
status is normal.  
None.  
RMG_0089  
Executed update registration.  
TABLE 6.19 Messages in the [Exportation of the REMCS settings] window  
Message code  
RMG_0002  
RMG_0004  
Message  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Invalid entry.  
Action  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Enter a valid directory.  
Enter data for the item.  
None.  
RMG_0015  
RMG_0033  
RMG_0036  
Invalid directory name specified.  
Required entry.  
The frame display of the exportation of the  
environment information and the customer  
information has completed.  
Failed to export the environment  
information.(xxx)  
RMG_0120  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
RMG_0121  
RMG_0122  
Failed to export the customer  
information.(xxx)  
window and try again. If the  
C122-E180-01EN  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
problem is not solved,  
contact the support center.  
None.  
Exportation of the environment information  
has been completed.  
Exportation of the customer information has  
been completed.  
RMG_0123  
RMG_0124  
RMG_0125  
RMG_0126  
Export customer information to a file.  
Export the environment information to a file.  
Close this screen after you finish export.  
Click the [OK] or [Cancel]  
button  
Close the screen after  
finishing export.  
-
TABLE 6.20 Messages in the [Connection check] window or [Connection check information] window  
Message code  
RMG_0001  
Message  
Action  
Failed to get Machine status. (xxx)  
Invalid CGI parameter specified.  
Failed to make frame screen data. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Correct the entered value.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Click the [OK] or [Cancel]  
button  
RMG_0002  
RMG_0004  
RMG_0015  
Invalid CGI parameter specified.  
Failed to setting Machine status.(xxx)  
RMG_0041  
Execute the connection check. Are you sure?  
RMG_0053  
RMG_0055  
RMG_0056  
Connection check frame display completed.  
Failed in the connection check notification.  
(xxx)  
RMG_0058  
RMG_0181  
Connection check notification completed.  
Invalid E-mail address specified.  
Enter E-mail address of administrator or  
installer.  
None.  
Enter a valid value.  
RMG_0182  
RMG_0183  
Specify a valid value.  
Specify [E-mail address for receiving results.]. Enter a valid value.  
TABLE 6.21 Messages in the [Result of connection check] window  
Message code  
Message  
Action  
RMG_0002  
RMG_0004  
RMG_0041  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Failed to setting Machine status. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Check whether the network  
status is normal.  
RMG_0056  
RMG_0058  
RMG_0185  
Failed in the connection check  
notification.(xxx)  
Connection check notification completed.  
None.  
None.  
Connection check frame display completed.  
TABLE 6.22 Messages in the [Temporary Disconnection] window or [Reconnection] window  
Message code  
RMG_0001  
RMG_0002  
RMG_0004  
Message  
Action  
Failed to get Machine status. (xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Click the [OK] or [Cancel]  
button.  
RMG_0041  
Failed to setting Machine status.(xxx)  
Execute temporary disconnection to the  
REMCS Center. Are you sure?  
Reconnection to the REMCS Center  
RMG_0059  
RMG_0060  
None.  
C122-E180-01EN  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
completed.  
Temporary disconnection to the REMCS  
Center completed.  
RMG_0061  
Temporary disconnection frame display  
completed.  
Reconnection frame display completed.  
Execute reconnection to the REMCS Center.  
Are you sure?  
RMG_0062  
RMG_0063  
RMG_0064  
Click the [OK] or [Cancel]  
button.  
Registration has not executed, Setup is  
incomplete.  
Retry after registration is  
complete.  
RMG_0092  
TABLE 6.23 Message in the [Sending Hardware Configuration Information] window  
Message code  
RMG_0002  
Message  
Action  
Failed to make frame screen data. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0004  
Invalid CGI parameter specified.  
Sending Hardware Configuration Information  
frame display completed.  
Sending hardware configuration information  
completed.  
Failed to send hardware configuration  
information. (xxx)  
Send hardware configuration information to  
the REMCS Center.  
RMG_0130  
RMG_0132  
RMG_0133  
RMG_0136  
Check whether the network  
status is normal.  
Click the [OK] or [Cancel]  
button.  
Execute hardware configuration information  
sending. Confirm sending result on event log  
display frame.  
Hardware configuration information sending  
started.  
Confirm sending result on  
event log display frame.  
RMG_0138  
RMG_0140  
None.  
TABLE 6.24 Message in the [Sending Software Configuration Information] window  
Message code  
Message  
Action  
RMG_0002  
Failed to make frame screen data. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0004  
Invalid CGI parameter specified.  
Sending Software Configuration Information  
frame display completed.  
Sending software configuration information  
completed.  
Failed to send software configuration  
information. (xxx)  
Send software configuration information to the Click the [OK] or [Cancel]  
RMG_0131  
RMG_0134  
RMG_0135  
RMG_0137  
Check whether the network  
status is normal.  
REMCS Center.  
button.  
Execute software configuration information  
sending. Confirm sending result on event log  
display frame.  
Software configuration information sending  
started.  
Confirm sending result on  
event log display frame.  
RMG_0139  
RMG_0141  
None.  
TABLE 6.25 Messages in the CE initial frame  
Message code  
Message  
Action  
RMG_0002  
Failed to make frame screen data. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0004  
Invalid CGI parameter specified.  
C122-E180-01EN  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
RMG_0009  
FE initial frame display completed.  
None.  
TABLE 6.26 Messages in the [Environment settings] window  
Message code  
RMG_0001  
Message  
Failed to get Machine status.(xxx)  
\n(MachineID=xxxxxx)  
Action  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Correct the entered value.  
RMG_0002  
RMG_0004  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
RMG_0015  
RMG_0016  
Invalid entry.  
Input value is out of range.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
RMG_0018  
RMG_0019  
RMG_0021  
RMG_0022  
Failed to get registration data.(xxx)  
contact the support center.  
Settings of detail environment frame display  
completed.  
None.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
Failed to register REMCS environment  
data.(xxx)  
Registration of REMCS environment data  
completed. None.  
REMCS environment data registration  
completed.  
Required entry. Enter a valid value.  
Execute registration of REMCS environment  
data. Are you sure?  
RMG_0023  
RMG_0036  
RMG_0037  
Enter a valid value.  
Click the [OK] or [Cancel]  
button.  
All events are not sent to the REMCS Center  
until environment setting is completed . Are  
you sure?  
RMG_0189  
TABLE 6.27 Messages in the [Selecting REMCS Center] window  
Message  
Message code  
Action  
RMG_0002  
RMG_0004  
RMG_0018  
RMG_0027  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
Failed to get registration data. (xxx)  
Failed to change Machine status.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0097  
RMG_0098  
Failed to read connection point list file. (xxx)  
Select REMCS Center frame display  
completed. None.  
None.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0099  
Failed to change the REMCS Center. (xxx)  
The Connected REMCS Center change  
completed. None.  
Change the REMCS Center address  
completed.  
Change the REMCS Center address. Execute  
registration again.  
RMG_0100  
RMG_0101  
RMG_0102  
RMG_0103  
Perform registration.  
Change the REMCS Center address. Are you Click the [OK] or [Cancel]  
sure?  
button.  
RMG_0150  
RMG_0172  
Failed to read setting file. (xxx)  
Failed to get Destination information. (xxx)  
If the error still occurs when  
you retry the operation, exit  
C122-E180-01EN  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
TABLE 6.28 Messages in the [Select language(Japanese or English)] window  
Message code  
RMG_0002  
RMG_0004  
Message  
Action  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0041  
Failed to setting Machine status.(xxx)  
Select language(Japanese or English) frame  
display completed.  
RMG_0162  
None.  
Change language. After this operation, you  
have to execute registration again. Are you  
sure?  
Click the [OK] or [Cancel]  
button.  
RMG_0163  
RMG_0164  
Failed to change language to Japanese.(xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Proceed with registration.  
RMG_0165  
Failed to change language to English.(xxx)  
RMG_0166  
RMG_0167  
Change language to Japanese completed.  
Changing language to English completed.  
Click the [OK] or [Cancel]  
button.  
RMG_0190  
Change language.Are you sure?  
TABLE 6.29 Messages in the [Select to Display Machine ID or Machine Unique Name] window  
Message code  
RMG_0002  
Message  
Action  
Failed to make frame screen data. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Click the [OK] or [Cancel]  
button.  
RMG_0004  
Invalid CGI parameter specified.  
RMG_0104  
Change machine name. Are you sure?  
Machine name display change frame display  
completed.  
Changing machine name display completed.  
None.  
RMG_0105  
RMG_0106  
TABLE 6.30 Messages in the processing progress display window  
Message code  
Message  
Action  
RMG_0002  
Failed to make frame screen data. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
RMG_0004  
Invalid CGI parameter specified.  
TABLE 6.31 Messages in the [Deleting the personal information] window  
Message code  
Message  
Action  
RMG_0002  
Failed to make frame screen data. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Click the [OK] or [Cancel]  
button.  
RMG_0004  
Invalid CGI parameter specified.  
Personal information is deleted. Are you  
sure?  
RMG_0195  
C122-E180-01EN  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 6 REMCS Messages  
6.1 Messages in REMCS Windows  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0196  
Failed to delete personal information.(xxx)  
Deleting the personal information is  
completed.  
Personal information deletion frame display  
has been completed.  
RMG_0209  
RMG_0210  
TABLE 6.32 Messages in the [Replacement of certificates] window  
Message code  
Message  
Action  
RMG_0002  
Failed to make frame screen data. (xxx)  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Enter a valid directory.  
RMG_0004  
Invalid CGI parameter specified.  
RMG_0033  
RMG_0036  
Invalid directory name specified.  
Required entry.  
Enter data for the item.  
Check the entered directory  
RMG_0142  
RMG_0211  
The file doesn't exist in the selected directory. name and file name, and  
enter them correctly.  
The specified file cannot be upload.  
Enter a valid file name.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
None.  
RMG_0212  
Failed to upload the certificates.(xxx)  
Upload of the certificates has been  
completed.  
RMG_0213  
RMG_0214  
RMG_0215  
RMG_0224  
The frame display of the permutation of the  
certificates completed.  
This certificate cannot be verified up to a CA  
certificate.  
This certificate is the same as the one used  
now. The certificate need not be imported.  
Confirm that the specified  
certificate is valid.  
Confirm the file to be  
imported.  
TABLE 6.33 Messages in the [Confirmation of certificate] window  
Message  
Message code  
Action  
RMG_0001  
RMG_0002  
RMG_0004  
Failed to get Machine status.(xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Click the [OK] or [Cancel]  
button.  
RMG_0041  
Failed to setting Machine status.(xxx)  
The certificates will be replaced. Once the  
replacement of certificates proceeds, the  
report to the REMCS center will not be done  
until connected confirmation is completed.  
Are you sure?  
RMG_0216  
RMG_0217  
The frame display of confirmation of the  
certificate has been completed.  
None.  
Replace the certificate  
Failed to replace the certificate. Try to replace again. If the problem is not  
RMG_0218  
RMG_0219  
the certificate again. (xxx)  
solved, contact the support  
center.  
Replacing the certificate has been completed. None.  
C122-E180-01EN  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 6 REMCS Messages  
6.2 Communication Error Messages (SMTP Communication)  
TABLE 6.34 Messages in the [Replacement to the previous certificate] window  
Message code  
RMG_0001  
RMG_0002  
RMG_0004  
Message  
Action  
Failed to get Machine status.(xxx)  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
contact the support center.  
Click the [OK] or [Cancel]  
button.  
RMG_0041  
Failed to setting Machine status.(xxx)  
The certificates will be replaced. Once the  
replacement of certificates proceeds, the  
report to the REMCS center will not be done  
until connected confirmation is completed.  
Are you sure?  
RMG_0216  
RMG_0220  
The frame display of the previous certificate  
restoration has been completed.  
None.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
Failed to restore to the previous certificate.  
(xxx)  
RMG_0221  
RMG_0222  
contact the support center.  
The restoration to the previous certificate has  
been completed.  
None.  
TABLE 6.35 Messages in the [Display of certificate] window  
Message code  
Message  
Action  
RMG_0002  
Failed to make frame screen data. (xxx)  
Invalid CGI parameter specified.  
If the error still occurs when  
you retry the operation, exit  
and restart the REMCS  
window and try again. If the  
problem is not solved,  
RMG_0004  
contact the support center.  
The frame display of the certificate has been  
completed.  
RMG_0223  
None.  
6.2 Communication Error Messages (SMTP Communication)  
The following list shows the error messages displayed in the windows when communication errors occur.  
The communication error messages also indicate the action to be taken. Handle errors by referring to this  
information. If the problem is not solved even if action is taken, contact the support center.  
In messages, RL indicates the return value of the REMCS library, and ML indicates the return value of the e-  
mail sending part.  
TABLE 6.36 List of communication error messages (SMTP communication)  
Message code  
RMG_2000  
Message  
(SMTP)There is no valid E-Mail address.  
The E-Mail address is not set up correctly.  
RL:xxx,ML:xxx  
RMG_2001  
RMG_2002  
(SMTP)Insufficient memory to run this operation.  
Please quit unnecessary applications, and try again.  
RL:xxx,ML:xxx  
(SMTP)File access error. There is no file. Please confirm  
following check.  
- Please check whether /var capacity is sufficient.  
RL:xxx,ML:xxx  
RMG_2003  
RMG_2004  
(SMTP)Communication timeout error was detected.  
Please try again after several minutes.  
When you do not solve the trouble, please check the network  
between the mail(SMTP) server, and check whether the SMTP  
server is running.  
RL:xxx,ML:xxx  
(SMTP)An error was detected by the specified mail(SMTP)  
C122-E180-01EN  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
CHAPTER 6 REMCS Messages  
6.2 Communication Error Messages (SMTP Communication)  
server.  
Please improve environment with reference to the following  
messages.  
(Message from the SMTP server)  
xxxxxxxxxxxxxxxxxxxx  
RL:xxx,ML:xxx  
RMG_2005  
(SMTP)Unable to connect the specified mail(SMTP) Server.  
Error was detected during communication to the specified mail  
(SMTP) server.  
The following causes can be considered.  
- The SMTP server name is wrong.  
- When the DNS server is used, the DNS server is not running.  
- The problem of the network between mail (SMTP) server.  
(Message from the SMTP server)  
xxxxxxxxxxxxxxxxxxxx  
RL:xxx,ML:xxx  
RMG_2006  
RMG_2007  
(SMTP)Unable to connect the specified mail(SMTP) Server.  
The following causes can be considered.  
- The SMTP server name is wrong.  
- When the DNS server is used, the DNS server is not running.  
- The problem of the network between mail (SMTP) server.  
(Message from the SMTP server)  
xxxxxxxxxxxxxxxxxxxx  
RL:xxx,ML:xxx\n  
(SMTP)An error was detected between the mail(POP3) server.  
POP before SMTPauthentication failed.  
The following causes can be considered.  
- The POP3 server name is wrong.  
- User name is wrong.  
- Passwd is wrong.  
(Message from the POP3 server)  
xxxxxxxxxxxxxxxxxxxx  
RL:xxx,ML:xxx  
RMG_2008  
(SMTP)An error was detected between the mail(POP3) server.  
An error was detected during communication to the specified  
POP3 server.  
The following causes can be considered.  
- The POP3 server name is wrong.  
- When the DNS server is used, the DNS server is not running.  
- The problem of the network between POP3 server.  
(Message from the POP3 server)  
xxxxxxxxxxxxxxxxxxxx  
RL:xxx,ML:xxx  
RMG_2009  
RMG_2010  
(SMTP)The error was detected between the mail(POP3) server.  
The timeout error occurred in communication with a POP3  
server.  
- The problem of the network between POP3server.  
- POP3 server is not running.  
RL:xxx,ML:xxx  
(SMTP)An error was detected during communication to the  
specified mail(POP3) server.  
The POP3 server name is wrong, or the POP3 server is not  
running.  
The following causes can be considered.  
- The POP3 server name is wrong.  
- When the DNS server is used, the DNS server is not running.  
- The problem of the network between POP3 server.  
(Message from the POP3 server)  
xxxxxxxxxxxxxxxxxxxx  
RL:xxx,ML:xxx  
RMG_2011  
(SMTP)The error was detected during communication to the  
specified mail(SMTP) server.  
Authentication failed on SMTP server.  
The user name or password is wrong, so it cannot authenticate  
C122-E180-01EN  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 6 REMCS Messages  
6.3 Other Error Messages  
on SMTP server.  
(Message from the POP3 server)  
xxxxxxxxxxxxxxxxxxxx  
RL:xxx,ML:xxx  
RMG_2012  
(SMTP)An error was detected during communication to the  
specified mail(SMTP) server.  
The specified SMTP server does not support SMTP AUTH. Or  
the SMTP server does not support specified auth type.  
The following causes can be considered.  
- Specified SMTP server is wrong.  
- Specified auth type is wrong.  
(Message from the SMTP server)  
xxxxxxxxxxxxxxxxxxxx  
RL:xxx,ML:xxx  
6.3 Other Error Messages  
If an error message not listed above is displayed, exit and restart the REMCS window and try again.  
If the problem is not solved, contact the support center.  
C122-E180-01EN  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 7 MMB Log Collection  
7.1 MMB Log Collection  
CHAPTER 7 MMB Log Collection  
This chapter describes MMB log collection.  
7.1 MMB Log Collection  
If a problem such as being unable to send e-mail messages to the REMCS Center occurs, the MMB  
operation log may need to be used as troubleshooting information. Following the instructions from the  
support center, select [System] - [System Event Log] from the MMB Web-UI menu to download the log kept  
by the MMB. For details of the operation, see Section 1.2.2 [System Event Log] window in the  
PRIMEQUEST 2000 Series Tool Reference (C122-E177EN).  
Hand over the downloaded log to a field engineer.  
C122-E180-01EN  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 8 Notes on Using REMCS GUI  
8.1 Notes on Using REMCS GUI  
CHAPTER 8 Notes on Using REMCS GUI  
This chapter describes the notes on using the REMCS GUI.  
8.1 Notes on Using REMCS GUI  
The REMCS GUI is displayed in a separate window when the REMCS menu is selected from the MMB Web  
UI.  
At this time, if a security software product with a firewall function has been installed on the personal  
computer or the like used to run the Web browser, it may block cookies or other information from the site  
being browsed depending on the default settings. Such products include Symantec Client Firewall and  
Norton Internet Security manufactured by Symantec Corporation. In this case, a message window displaying  
[This session was disconnected.] appears, and the REMCS window is not displayed. The setting must be  
changed so that cookies or other information from the browsed sites are not blocked.  
The setting procedure for cases where Symantec Client Firewall is used is provided below. For details on  
other software products, see the manuals and the HELP menu for each product.  
1. Run Symantec Client Firewall to display its window.  
2. Select [Privacy control], and then click the [Setting] button.  
3. When the [Privacy control] window appears, click the [Custom level] button.  
4. When the [Customizing privacy setting] window appears, select [None: Permits cookies] for [Cookie  
block] and uncheck [Enable browser privacy]. Then click the [OK] button.  
5. When the [Privacy control] window is displayed again, click the [OK] button to complete the setting.  
After the REMCS GUI is displayed, the connection is canceled if no input occurs within the time specified for  
[Timeout] of [Web (HTTP/HTTPS)]. [Web (HTTP/HTTPS)] is accessed by selecting [Network] - [Network  
Protocols] in the [MMB Web-UI] window.  
Only one user can use the REMCS GUI concurrently. If any other user is already logged in, the following  
window appears:  
TABLE 8.1 REMCS message window  
C122-E180-01EN  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 8 Notes on Using REMCS GUI  
8.1 Notes on Using REMCS GUI  
Clicking the [Compulsory REMCS menu opening] button logs you in by forcibly logging out the current login  
user.  
Click the [Close] button to close the window.  
If the time zone setting has been changed from the [MMB Web-UI] window, perform the following operation  
to update the REMCS Center information:  
-
Execute the periodic connection schedule settings.  
The periodic connection schedule of REMCS is interpreted with the time zone currently set.  
C122-E180-01EN  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ei Electronics Smoke Alarm Ei405TY RF User Manual
Eiki Cassette Player 5090A User Manual
Excalibur electronic Motorized Toy Car 9345 User Manual
Extron electronic Stereo Amplifier MPA 181T User Manual
Fellowes Paper Shredder HD 10CS User Manual
GE Air Cleaner SERIES B 480 User Manual
GE Cordless Telephone 29111 Series User Manual
GE Indoor Furnishings ET 16 User Manual
Gembird MP3 Player LECTEUR MOBILITY CLASSIC MP3 User Manual
Goldstar Computer Monitor W1942T User Manual