Frymaster Fryer 819 5432 User Manual

Planned Maintenance  
System: Maintenance  
Requirement Card  
(MRC)  
Grill/Fryer Stacks  
CARD NO.  
Frymaster L.L.C.  
Pictures and additional  
information:  
12  
Corresponding Chapter of  
Equipment Manual  
Precaution  
None  
Clean Grill/Fryer Stacks  
When  
Quarterly-Grill Stacks  
Semi-Annually- Fryer  
Stacks  
1. Call service agency to clean grill stacks.  
Note: Upon completion of stack cleaning, it is necessary for management to follow up on the  
service agency. If the checks are not satisfactory, call the service agency.  
Tools  
Flashlight; protective  
goggles  
2. Inspect the back of the grill. Ensure that it is clean and free of grease. See MRC 11A (Clean  
Behind Grills).  
3. Check to ensure the firewall is clean and free of grease.  
4. Check the fusible link visually to ensure it is clean and in place.  
Caution: Use protective goggles to protect against any loose debris.  
5. Check the inside of the hood to ensure it is clean and free of grease.  
6. Inspect the inside of the stack with a flashlight. Ensure that is clean and free of grease.  
7. Proceed to the roof for the next checks.  
8. Turn the fan disconnect switch located at the fan to the OFF position.  
9. Check the exhaust fan and surrounding areas to make sure it is clean and free of grease.  
10. Tilt fan up and look into the stack to see that it is free of grease.  
11. Return fan to the “down” position and turn fan switch back ON.  
12. Stack cleaning is complete.  
1 of 1  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
* 8 1 9 5 4 3 2 *  
Card 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Check Calibration (With MACC100, M100A, M100B or M2000 Computer).  
Continued from previous  
page.  
12. Note: The computer should rarely be out of the ±5°F (±3°C) range, as it is preset at the  
factory.  
13. Repeat all the above steps for remaining fryers.  
Check Calibration (With Thermostat Controller Only)  
When  
Twice Monthly  
1. Turn vat ON and set the thermostat knob to the correct cooking temperature.  
2. Allow the vat to cycle OFF after reaching the cooking temperature.  
Tools  
Digital thermometer with fry  
vat probe, 1/8” (3 mm) flat-  
blade screwdriver, Pro Fry  
computer.  
3. The cooking oil should be at the normal (upper) oil-level line at cooking temperature.  
Add or remove cooking oil as needed. All cooking oil should be melted before  
proceeding.  
4. Insert the fry vat probe into the cooking oil to within one (1) inch of the fryer  
temperature-probe tip, approximately 3" (7.6 cm) below the surface. If using Pro Fry  
computer display temperature PC # 326/327 or NCC #1540/1541, the computer probe  
should be used.  
5. Allow the vat to cycle ON and OFF three times.  
6. After the stabilizing period, the instant vat cycles ON for the fourth time (as noted by the  
fryer heat light turning ON) the cooking oil temperature should be within ±5°F (±3°C)  
of the thermostat setting.  
7. If it is within ±5°F (±3°C), calibration is complete.  
8. If not, adjustments can be made by:  
a. Locating temperature control knob set screw.  
b. Using a 1/8" (3 mm) flat-blade screwdriver, loosen the setscrew until the knob  
rotates on the insert inside the knob. Rotate the knob on the insert CLOCKWISE to  
INCREASE the temperature setting and COUNTER-CLOCKWISE TO  
DECREASE.  
c. Carefully hold the knob and tighten the setscrew using the 1/8" (3 mm) flat-blade  
screwdriver. Do not over tighten the setscrews.  
9. Repeat Steps 1 through 9 for remaining fryers.  
2 of 2  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planned Maintenance  
System: Maintenance  
Requirement Card  
(MRC)  
CARD NO.  
Fryers  
14A  
Frymaster Electric & Gas Fryers  
Pictures and additional  
information:  
Corresponding Chapter of  
Equipment Manual  
Frymaster Electric Fryer Models:  
BIMH14 & MACH14 Series (With Thermostat Controller)  
BIMH14 & MACH14 Series (With MACC100 Computer)  
BIMH14 & MACH14 Series (With MACC100A Computer)  
BIH14 & MH14 Series (With M100A Computer)  
BIH14 & MH14 Series (With M100B Computer)  
BIH14, BIPH14, MPH14 & MH14 Series (With M2000 Computer)  
BIRE14 and MRE Series (With M2000 Computer)  
Frymaster Gas Fryer Models:  
BIMH52 & MACH52 Series (With Thermostat Controller)  
BIMH52 & MACH52 Series (With MACC100 Computer)  
BIMH52 & MACH52 Series (With M100A Computer)  
BIMH52 & MACH52 Series (With MACC100A Computer)  
BIH52 & MH52 Series (With M100B Computer)  
BIH52, BIPH52, MPH52 & MH52 Series (With M2000 Computer)  
BIPH55 and MPH55 Series (With M2000 Computer)  
Precaution  
Cooking oil temperatures will cause severe skin burns.  
HAZARD COMMUNICATION STANDARD (HCS) – The procedure(s) in this manual  
include the use of chemical products. These chemical products will be highlighted with  
italic letters followed by the abbreviation (HCS). See Hazard Communication Standard  
(HCS) manual for the appropriate Material Safety Data Sheet(s)  
When  
Weekly  
Clean Behind Fryers (All Frymaster Models).  
Tools  
McD All Purpose  
Purpose:  
Concentrate (A.P.C.)  
(HCS), towels, nylon pot  
brush, bucket, mop, putty  
knife, high/low brush.  
The purpose of cleaning behind the fryer weekly is to prevent significant grease buildup.  
This also meets McDonald’s cleanliness standards. Not cleaning behind the fryers on a  
weekly basis could become a fire hazard to your restaurant.  
1. Turn all fryer power switches to “OFF”.  
2. Remove stainless steel grease trough located below the grease filters by lifting it off the  
holding screws and pour all the grease into the cooking oil removal cart.  
3. Gas Fryers - Shut OFF the gas supply using the manual gas shut-off valve. Then  
disconnect the gas line from the fryer.  
Caution: Do not use the quick-disconnect connection to shut off the gas supply to fryers  
and grills. Use the manual gas shut-off valve for that piece of equipment. If the piece of  
equipment does not have a manual gas shut-off, one must be installed. The manual gas  
shut-off should be located on the supply line before the quick-disconnect connection for  
the piece of equipment.  
4. Release locks on fryer wheels.  
Caution: Cooking oil in the vats may be hot and may splash when moving fryer.  
5. Lift front of fryer capping piece (if installed) to allow backsplash to clear filter shelf.  
6. Carefully roll the fryer away from firewall far enough for capping piece backsplash (if  
installed) to clear the filter shelf.  
7. Secure capping piece of fryer.  
1 of 8  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clean Behind Fryers (All Frymaster Models).  
Continued from previous  
page.  
8. Place vat covers over all vats.  
9. Remove fryer far enough to get behind the fryer.  
10. Disconnect electrical cord(s) from the receptacle.  
Note: Do not disconnect cord by pulling on cord! Disconnect by pulling plug out of the  
receptacle only!  
11. Remove grease filters from exhaust hood. Take to back sink for soaking in a hot  
solution of McD A.P.C. (HCS) from the sink proportioner.  
12. Using a putty knife, scrape off all soft grease and hard carbon from area behind the fryer  
using the following sequence:  
Caution: Be careful NOT to break the Fire Protection FUSIBLE LINK in lower center  
area of stack. This will activate the fire extinguishing system.  
a. Accessible parts of stack.  
b. Back of hood.  
c. Sides of hood.  
d. Grease filter recess area.  
e. Flue restricter (gas only).  
f. All sheet metal around fryer.  
g. Removable gravity blade (gas only).  
h. Seal angle (gas only).  
i. Standoff piece.  
j. Fryer stand.  
Caution: Do not drop any soft grease and hard carbon into the fryer flue passage.  
13. Using a hot solution of McD A.P.C. (HCS) from the sink proportioner, a nylon pot brush and  
the high/low brush, scrub all the areas listed in order in Step 12 including the floor.  
14. Wipe all areas with towels until clean and dry.  
15. Have manager inspect and approve cleaning before proceeding.  
16. Using nylon pot brush and a hot solution of McD A.P.C. (HCS) from the sink proportioner in  
a bucket, wash the legs and wheels. Wipe dry.  
17. Using a mop and a hot solution of McD A.P.C. (HCS) from the sink proportioner, mop entire  
floor area around fryer.  
Note: Make sure all surfaces are dry before proceeding.  
Caution: Cooking oil in vat may be hot and may splash when moving fryer.  
18. Carefully roll fryer back close enough to connect electrical cord(s). After plugging in cords,  
roll fryer close to the filter shelf.  
19. Remove the vat covers from all vats.  
20. Lift front of fryer capping piece until back splash clears the filter shelf while rolling fryer  
into its normal position.  
21. Gas Fryers – Check both ends of gas quick-disconnect connections for grease and wipe off if  
necessary.  
22. Gas Fryers – Connect gas coupling.  
Caution: Ensure gas coupling is fully interlocked.  
23. Lock wheels in place, and install grease filters and grease troughs.  
24. Gas Fryers – Turn ON the gas supply using the manual gas shut-off valve. Then re-light the  
burners. Once the burners ignite, turn the controller OFF.  
2 of 8  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replace Filter System O-Rings (BIMH, BIPH, BIRE and BIH Models Only)  
When  
Quarterly  
Caution: O-Rings should be changed only when the filter pan is completely empty, and  
the unit is cool.  
Tools  
1. Pull filter assembly from the cabinet.  
Towels, Appropriate O-  
rings. (For Footprint III  
systems, use 1 each Part  
No. 816-0181. For  
Footprint II systems, use 1  
each Part No. 816-0117,  
and 2 each Part No. 826-  
1392).  
2. Remove empty filter pan from the filter base (for Footprint II system, lift inner pan out  
of the outer pan).  
3. Remove O-ring from the check valve assembly at bottom of pan, and replace with new  
O-ring (Part No. 816-0181). (For Footprint II system, remove inner pan O-ring and  
replace with new O-ring Part No. 816-0117, and remove the two O-rings from around  
the oil pump disconnect tube, and install 2 each Part No. 826-1392.)  
Note: These O-rings are specifically manufactured for use with hot cooking oils.  
Generic O-rings cannot be used in this application.  
When  
Semi-Annually (Gas  
Fryers Only)  
Boil-out Fryer Pots (With Thermostat Controller or MACC100 Computer  
Only)  
Caution: Use protective goggles, aprons and gloves for all of the steps in this procedure.  
Caution: Only boil-out one fryer at a time.  
Quarterly (Electric Fryers  
Only)  
Note: To prevent accidental tripping of the Ansul system, grease filters should be in  
place, with at least one vat in operation to ensure the exhaust fan stays on.  
Tools  
Protective gloves, apron,  
goggles, McD All Purpose  
Concentrate (A.P.C.)  
(HCS), cooking oil disposal  
cart, sealable metal bucket  
(5 gallon) (19 liter), nylon  
pot brush, nylon scrubbing  
pad and McD Heavy duty  
Degreaser (HCS).  
1. Turn power ON/OFF switch to “OFF”. Remove filter pan from fryer cabinet.  
2. Pull the swivel drain spout (if so equipped) outward to a suitable position to drain  
cooking oil into the filter pan or cooking oil disposal cart.  
3. Place the filter pan or cooking oil disposal cart under the drain spout.  
4. Carefully open the drain valve of the fryer to be boiled out and allow the cooking oil to  
drain from fry vat. Flush out any pieces of fried food and sediment.  
5. Close the drain valve and very carefully pour McD Heavy duty Degreaser (HCS) (2 full  
gallons (8-liters) per full-vat, or 1 gallon (4-liters) per split-vat section) into fryer pot  
without splattering.  
6. Remove fryer capping piece assembly (if so equipped) to expose carbon build-up.  
7. Finish filling the vat to the normal shortening level line with a hot solution of McD  
A.P.C. (HCS) drawn from the sink proportioner (the use of HOT water will reduce  
warm-up time).  
8. Fryers equipped with MACC100 Computer, press the  
then set to BOIL-OUT program.  
button to turn computer ON,  
Note: Basket support rack must be in place in the frypot.  
Note: Solution will heat up to simmer condition and the temperature will be maintained at  
195ºF (91ºC).  
9. Allow fryer to operate in BOIL-OUT program for one hour.  
10. If fryer is equipped with Thermostat Controller, turn power switch to “ON” and set the  
temperature dial to the lowest setting.  
11. Bring to a soft, rolling simmer for approximately one hour. DO NOT hard boil.  
Caution: NEVER LEAVE THE FRYER UNATTENDED. Necessary boiling time may  
vary depending on condition of vat.  
12. Insert fry baskets to be cleaned into the boiling solution. Remove, when clean, and rinse  
thoroughly.  
3 of 8  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Boil-out Fryer Pots (With Thermostat Controller or MACC100 Computer  
Continued from previous  
page.  
Only)  
Caution: Do not clean any aluminum parts in this solution.  
13. Using the clean-out rod, remove fry basket support rack and rinse thoroughly in hot  
water.  
Caution: Support rack is hot when removed from vat. Do not touch with unprotected  
hands.  
14. Using a nylon pot brush, scrub tank side, front and back walls, and top areas to remove  
remaining carbon deposits, being careful not to splash.  
15. Turn the power switch to “OFF”.  
16. Place a 5-gallon (19-liter) grease bucket under the fryer drain spout. Open drain valve  
slowly, allowing solution to flow slowly into bucket.  
Note: Place only 2- or 3-gallons (8- or 11-liters) of solution into container at a time.  
(This solution may be reused in another fryer.)  
Caution: Do not splash solution on skin or clothing. Bucket and solution will be hot.  
17. If boil out solution is to be used in another fryer, use several containers to store the  
solution until ready to proceed with the next fryer vat. If boil-out solution is to be  
discarded, pour solution into sink drain.  
Note: If boil-out compound is to be used in another fryer, use within 3 hours or discard.  
18. Using a 5 gallon (19 liter) grease bucket, draw 3 gallons (11 liters) of McD A.P.C.  
(HCS) from the sink proportioner. If a sink proportioner is not being used, mix 6 fluid  
ounces (3/4 cups/177 ml) of McD A.P.C. (HCS) to 3-gallons (11-liters) of warm water  
and pour solution into fryer vat.  
19. Using a nylon pot brush, scrub tank side, front, back walls and top areas to remove  
remaining carbon deposits.  
20. Place bucket under drain valve and open drain valve slowly to drain dirty solution out.  
Note: Do not place more than 2-or 3-gallons (8- or 11-liters) of solution into bucket at a  
time.  
Caution: Do not drain boil-out solution or water into the built-in filtration filter pan or  
the cooking oil disposal cart.  
Caution: Do not splash solution on skin or clothing. Bucket and solution will be hot.  
21. Remove bucket and discard solution into sink drain.  
22. Place bucket under fryer drain valve and open valve.  
Note: If there is any carbon left in the vat, clean it now with nylon scouring pad, then  
rinse and drain vat.  
23. Rinse fryer vat thoroughly TWO TIMES with warm (100ºF/38ºC) water and wipe with  
damp towel. Close the fryer drain valve.  
24. Thoroughly dry inside fryer vat, especially in the drain valve area.  
25. Using proper procedure, fill vat with proper amount of cooking oil.  
26. Place basket support racks into cool oil (or on top of cooking oil).  
27. After cooking oil has melted down, skim off any particles of carbon floating on the  
surface of cooking oil.  
28. Repeat procedures for each remaining vat.  
29. Season baskets and racks in fresh cooking oil prior to use (approximately 2 minutes at  
cooking temperature).  
4 of 8  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Boil-out Fryer Pots (With Thermostat Controller or MACC100 Computer  
Continued from previous  
page.  
Only)  
30. Boil-out is complete.  
31. Push the swivel drain spout (if so equipped) back inside the fryer cabinet and carefully  
roll the filter pan back into the cabinet. (Some FootPrint II filter systems have a green  
HEATER ON light which will illuminate when the pan is properly positioned in the  
cabinet.)  
When  
Semi-Annually (Gas  
Fryers Only)  
Boil-out Fryer Pots (With MACC100A, M100A and M100B Computer Only)  
Caution: Use protective goggles, aprons and gloves for all of the steps in this procedure.  
Caution: Only boil out one fryer at a time.  
Quarterly (Electric Fryers  
Only)  
Note: To prevent accidental tripping of the Ansul system, grease filters should be in  
place, with at least one vat in operation to ensure the exhaust fan stays on.  
Tools  
Protective gloves, apron,  
goggles, McD All Purpose  
Concentrate (A.P.C.)  
(HCS), cooking oil disposal  
cart, sealable metal bucket  
(5 gallon) (19 liter), nylon  
pot brush, nylon scrubbing  
pad and McD Heavy duty  
Degreaser (HCS).  
1. Press the  
(MACC100A and M100A) or  
(M100B) button to turn fryer OFF.  
Remove filter pan from fryer cabinet.  
2. Pull the swivel drain spout (if so equipped) outward to a suitable position to drain  
cooking oil into the filter pan or cooking oil disposal cart.  
3. Place the filter pan or cooking oil disposal cart under the drain spout.  
4. Carefully open the drain valve of the fryer to be boiled out and allow the cooking oil to  
drain from fry vat. Flush out any pieces of fried food and sediment.  
5. Close the drain valve and very carefully pour McD Heavy duty Degreaser (HCS) (2 full  
gallons (8-liters) per full-vat, or 1 gallon (4-liters) per split-vat section) into fryer pot  
without splattering.  
6. Remove fryer capping piece assembly (if so equipped) to expose carbon build-up.  
7. Finish filling the vat to the normal shortening level line with a hot solution of McD  
A.P.C. (HCS) drawn from the sink proportioner (the use of HOT water will reduce  
warm-up time).  
8. Press the  
(MACC100A and M100A) or  
(M100B) button to turn fryer ON, then  
set menu to “BOIL-OUT.  
Note: Basket support rack must be in place in the frypot.  
Note: Solution will heat up to simmer condition and the temperature will be maintained  
at 195ºF (91ºC).  
9. Allow fryer to operate in BOIL-OUT program for one hour.  
10. Bring to a soft rolling simmer for approximately one hour. DO NOT hard boil.  
Caution: NEVER LEAVE THE FRYER UNATTENDED. Necessary boiling time may  
vary depending on condition of vat.  
11. Insert fry baskets to be cleaned into the boiling solution. Remove, when clean, and rinse  
thoroughly.  
12. Press the  
(MACC100A and M100A) or  
(M100B) button to turn fryer OFF.  
13. Place a 5-gallon (19-liter) grease bucket under the fryer drain spout. Open drain valve  
slowly, allowing solution to flow slowly into bucket.  
Note: Place only 2- or 3-gallons (8- or 11-liters) of solution into container at a time.  
(This solution may be reused in another fryer.)  
Caution: Do not splash solution on skin or clothing. Bucket and solution will be hot.  
5 of 8  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Boil-out Fryer Pots (With MACC100A, M100A and M100B Computer Only)  
Continued from previous  
page.  
14. If boil out solution is to be used in another fryer, use several containers to store the  
solution until ready to proceed with the next fryer vat. If boil-out solution is to be  
discarded, pour solution into sink drain.  
Note: If boil-out compound is to be used in another fryer, use within 3 hours or discard.  
15. Using a 5 gallon (19 liter) grease bucket, draw 3 gallons (11 liters) of McD A.P.C.  
(HCS) from the sink proportioner. If a sink proportioner is not being used, mix 6 fluid  
ounces (3/4 cups/177 ml) of McD A.P.C. (HCS) to 3-gallons (11-liters) of warm water  
and pour solution into fryer vat.  
16. Using a nylon pot brush, scrub tank side, front, back walls and top areas to remove  
remaining carbon deposits.  
17. Place bucket under drain valve and open drain valve slowly to drain dirty solution out.  
Note: Do not place more than 2-or 3-gallons (8- or 11-liters) of solution into bucket at a  
time.  
Caution: Do not drain boil-out solution or water into the built-in filtration filter pan or  
the cooking oil disposal cart.  
Caution: Do not splash solution on skin or clothing. Bucket and solution will be hot.  
18. Remove bucket and discard solution into sink drain.  
19. Place bucket under fryer drain valve and open valve.  
Note: If there is any carbon left in the vat, clean it now with nylon scouring pad, then  
rinse and drain vat.  
20. Rinse fryer vat thoroughly TWO TIMES with warm (100ºF/38ºC) water and wipe with  
damp towel. Close the fryer drain valve.  
21. Thoroughly dry inside fryer vat, especially in the drain valve area.  
22. Using proper procedure, fill vat with proper amount of cooking oil.  
23. Place basket support racks into cool oil (or on top of cooking oil).  
24. After cooking oil has melted down, skim off any particles of carbon floating on the  
surface of cooking oil.  
25. Repeat procedures for each remaining vat.  
26. Season baskets and racks in fresh cooking oil prior to use (approximately 2 minutes at  
cooking temperature).  
27. Boil-out is complete.  
When  
Semi-Annually (Gas  
Fryers Only)  
Boil-out Fryer Pots (With M2000 Computer Only)  
Boil-out must be programmed into the computer prior to the first boil-out procedure.  
Program the computer as follows:  
Quarterly (Electric Fryers  
Only)  
1. Press the  
2. Press the  
button to turn fryer OF F .  
Tools  
button. The left display shows c o d e .  
Protective gloves, apron,  
goggles, McD All Purpose  
Concentrate (A.P.C.) (HCS),  
cooking oil disposal cart,  
sealable metal bucket (5  
gallon) (19 liter), nylon pot  
brush, nylon scrubbing pad  
and McD Heavy duty  
Degreaser (HCS).  
1
0
1
3. Enter the code  
(16 5 0 ). Press the  
button to back through  
programmed items/numbered products until b o il o u t (#40 product position) is  
reached.  
4. Press a gray product  
will illuminate.  
button to store boil out. The green LED of the button pressed  
6 of 8  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Continued from previous  
page.  
5. Press the  
button to turn fryer OF F . Proceed with boil-out procedure.  
Boil-out Fryer Pots (With M2000 Computer Only)  
Caution: Use protective goggles, aprons and gloves for all of the steps in this procedure.  
Caution: Only boil out one fryer at a time.  
Note: To prevent accidental tripping of the Ansul system, grease filters should be in  
place, with at least one vat in operation to ensure the exhaust fan stays on.  
1. Press the  
button to turn fryer OF F . Remove filter pan from fryer cabinet.  
2. Pull the swivel drain spout (if so equipped) outward to a suitable position to drain  
cooking oil into the filter pan or cooking oil disposal cart.  
3. Place the filter pan or cooking oil disposal cart under the drain spout.  
4. Carefully open the drain valve of the fryer to be boiled out and allow the cooking oil to  
drain from fry vat. Flush out any pieces of fried food and sediment.  
5. Close the drain valve and very carefully pour McD Heavy duty Degreaser (HCS) (2 full  
gallons (8-liters) per full-vat, or 1 gallon (4-liters) per split-vat section) into fryer pot  
without splattering.  
6. Remove fryer capping piece assembly (if so equipped) to expose carbon build-up.  
7. Finish filling the vat to the normal shortening level line with a hot solution of McD  
A.P.C. (HCS) drawn from the sink proportioner (the use of HOT water will reduce  
warm-up time).  
8. Press the  
to turn fryer ON. Computer will display l o w t e mp .  
9. Press the gray product  
button used to store boil out programming.  
10. The computer will display  
or s t a r t b o il o u t .  
11. Press and hold either cook channel  
button under the vat being boiled out. Hold  
the button for approximately 5 seconds, and then release. Bo il o u t should appear in  
the display over button. The cook channel will be dedicated to boil out until changed,  
and have a setpoint of 195°F (91°C).  
12. Press the cook channel  
button under the b o il o u t display to start boil out.  
Note: Basket support rack must be in place in the frypot.  
Note: Solution will heat up to simmer condition and the temperature will be maintained  
at 195ºF (91ºC).  
13. Allow fryer to operate in BOIL-OUT program for one hour.  
14. Bring to a soft rolling simmer for approximately one hour. DO NOT hard boil.  
Caution: NEVER LEAVE THE FRYER UNATTENDED. Necessary boiling time may  
vary depending on condition of vat.  
15. Insert fry baskets to be cleaned into the boiling solution. Remove, when clean, and rinse  
thoroughly.  
16. Press the  
to turn fryer OFF.  
17. Place a 5-gallon (19-liter) grease bucket under the fryer drain spout. Open drain valve  
slowly, allowing solution to flow slowly into bucket.  
Note: Place only 2- or 3-gallons (8- or 11-liters) of solution into container at a time.  
(This solution may be reused in another fryer.)  
Caution: Do not splash solution on skin or clothing. Bucket and solution will be hot.  
7 of 8  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Boil-out Fryer Pots (With M2000 Computer Only)  
Continued from previous  
page.  
18. If boil out solution is to be used in another fryer, use several containers to store the  
solution until ready to proceed with the next fryer vat. If boil-out solution is to be  
discarded, pour solution into sink drain.  
Note: If boil-out compound is to be used in another fryer, use within 3 hours or discard.  
19. Using a 5 gallon (19 liter) grease bucket, draw 3 gallons (11 liters) of McD A.P.C.  
(HCS) from the sink proportioner. If a sink proportioner is not being used, mix 6 fluid  
ounces (3/4 cups/177 ml) of McD A.P.C. (HCS) to 3-gallons (11-liters) of warm water  
and pour solution into fryer vat.  
20. Using a nylon pot brush, scrub tank side, front, back walls and top areas to remove  
remaining carbon deposits.  
21. Place bucket under drain valve and open drain valve slowly to drain dirty solution out.  
Note: Do not place more than 2-or 3-gallons (8- or 11-liters) of solution into bucket at a  
time.  
Caution: Do not drain boil-out solution or water into the built-in filtration filter pan or  
the cooking oil disposal cart.  
Caution: Do not splash solution on skin or clothing. Bucket and solution will be hot.  
22. Remove bucket and discard solution into sink drain.  
23. Place bucket under fryer drain valve and open valve.  
Note: If there is any carbon left in the vat, clean it now with nylon scouring pad, then  
rinse and drain vat.  
24. Rinse fryer vat thoroughly TWO TIMES with warm (100ºF/38ºC) water and wipe with  
damp towel. Close the fryer drain valve.  
25. Thoroughly dry inside fryer vat, especially in the drain valve area.  
26. Using proper procedure, fill vat with proper amount of cooking oil.  
27. Place basket support racks into cool oil (or on top of cooking oil).  
28. After cooking oil has melted down, skim off any particles of carbon floating on the  
surface of cooking oil.  
29. Repeat procedures for each remaining vat.  
30. Season baskets and racks in fresh cooking oil prior to use (approximately 2 minutes at  
cooking temperature).  
31. Boil-out is complete.  
(
(
8 of 8  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 14A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planned Maintenance  
System: Maintenance  
Requirement Card  
(MRC)  
CARD NO.  
Fryers  
15  
Frymaster Electric & Gas Fryers  
Pictures and additional  
information:  
Corresponding Chapter of  
Equipment Manual  
Frymaster Electric Fryer Models:  
BIMH14 & MACH14 Series (With Thermostat Controller)  
BIMH14 & MACH14 Series (With MACC100 Computer)  
BIMH14 & MACH14 Series (With MACC100A Computer)  
BIH14 & MH14 Series (With M100A Computer)  
BIH14 & MH14 Series (With M100B Computer)  
BIH14, BIPH14, MPH14 & MH14 Series (With M2000 Computer)  
BIRE14 and MRE14 Series (With M2000 Computer)  
Frymaster Gas Fryer Models:  
BIMH52 & MACH52 Series (With Thermostat Controller)  
BIMH52 & MACH52 Series (With MACC100 Computer)  
BIMH52 & MACH52 Series (With M100A Computer)  
BIMH52 & MACH52 Series (With MACC100A Computer)  
BIH52 & MH52 Series (With M100B Computer)  
BIH52, BIPH52, MPH52 & MH52 Series (With M2000 Computer)  
BIPH55 and MPH55 Series (With M2000 Computer)  
Precaution  
Cooking oil temperatures will cause severe skin burns.  
When  
Monthly  
Recovery Check Time (With MACC100 computer only.)  
Tools  
Pad, pen.  
1. Grease filters should be in place and properly cleaned.  
2. Turn vat controller/computer "ON" and let cooking oil stabilize at cooking temperature.  
3. Allow the fryer to cycle OFF after reaching the cooking temperature.  
4. The cooking oil should be at the normal (upper) oil-level line at cooking temperature.  
Add or remove cooking oil as needed.  
Note: All cooking oil should be melted before proceeding.  
5. Access the recovery check program by pressing the  
button, or,  
or  
button on  
a split-vat, depending on which vat is being checked, until the display reads (alternating)  
"xxx SEC" and the date (displayed xx/xx/xx) from the previous test.  
Note: Only one side of a split-vat is to be checked at a time.  
6. Activate the date change display by pressing the following:  
a. Full-vat: Right display operate button  
b. Split-vat: Left display operate button  
or  
or  
.
or right display operate  
,
button  
or  
.
7. To change the date: press button  
of left display to change the date. Press button  
tens (year), then press button of right display to change the ones (year).  
of left display to change the month. Press button  
of right display to change the  
Note: A date must be displayed to perform a recovery time check. If no date is  
displayed, a date must be entered as described above.  
1 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recovery Check Time (With MACC100 computer only.)  
Continued from previous  
page.  
8. Start the recovery check by touching the following:  
a. Full-vat: Right  
b. Split-vat: Left  
button.  
button for the left or right  
button for the right side.  
Note: The display will show "REC xxx F" (or xxx C) indicating the actual vat  
temperature.  
9. When the display shows a vat temperature of 270°F (132°C) and is automatically  
stabilized at that temperature, agitate the cooking oil for one minute.  
10. The computer automatically starts the time check when the vat temperature exceeds  
274°F (134°C). Do not agitate further.  
11. At the end of the check, the display will show the recovery time as "xxx SEC". The  
computer again controls the fryer for a vat temperature equal to the set temperature.  
12. The recover test information may be recalled at any time by touching the respective  
button.  
Note: Recovery time should be less than 145 seconds for a gas fryer and less than 100  
seconds for an electric fryer.  
13. If the required recovery time cannot be attained, call service representative.  
14. To exit the recovery time check, press the  
then turning the computer back ON.  
twice, first turning the computer OFF,  
15. Repeat Steps 1 through 15 for each additional fryer until all have been checked.  
Recovery time check is complete.  
Recovery Check Time (With Thermostat Controller only.)  
1. Grease filters should be in place and properly cleaned.  
When  
Monthly  
2. Turn vat controller “ON” and let cooking oil stabilize at cooking temperature.  
3. Allow the fryer to cycle OFF after reaching the cooking temperature.  
Tools  
Stopwatch, digital  
thermometer with fry vat  
probe or Pro Fry computer,  
probe holder, paper, pen.  
4. The cooking oil should be at the normal (upper) oil-level line at cooking temperature.  
Add or remove cooking oil as needed. All cooking oil should be melted before  
proceeding.  
5. Insert the fry vat probe at the rear of the frypot, to within one (1) inch of the tip of the  
computer probe. If using the Pro Fry computer, display temperature PC# 326/327 or  
NCC #1540/1541, the computer probe should be used.  
6. Turn the thermostat knob to 270°F (132°C) and allow vat to cool for approximately 30  
minutes.  
7. When the display reads 270°F (132°C), turn the thermostat knob to 375°F (191°C) and  
begin timing.  
8. Record the time it takes for the cooking oil to reach 320°F (160°C).  
Note: Recovery time should be less than 145 seconds for a gas fryer and less than 100  
seconds for an electric fryer.  
2 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recovery Check Time (With Thermostat Controller only.)  
Continued from previous  
page.  
9. If the required recovery time cannot be attained, call service representative.  
Caution: Turn thermostat knob back to normal cooking temperature before putting fryer  
back in service.  
Recovery Check Time (With MACC100A, M100A, and M100B Computer  
only.)  
When  
Monthly  
Note: With the MACC100A, M-100A, and M100B cooking computers, Recovery Time  
Checks are performed automatically and updated each time the vat temperature rises  
from 250°F (121°C) to above 320°F (160°C).  
Tools  
Paper, pen.  
1. Turn the fry vat ON by pressing the  
button (MACC100A and M100A), or the  
button  
(M100B). The previously cooked product should be displayed on the computer.  
2. To display the most recent recovery test time, press the  
button in the following manner:  
Full-vat:  
Left  
or right  
button.  
button.  
button.  
Split-vat, left:  
Split-vat, right:  
Left  
Right  
3. Record the recovery time.  
Note: Recovery time should be less than 145 seconds for a gas fryer (less than 155  
seconds for M100B computers only), and less than 100 seconds for an electric fryer. If  
time is less than 145 seconds for gas (155 seconds—M100B only), or 100 for electric  
fryers, recovery time is acceptable. If the time displayed is greater than the required  
time, refer to the scratch calibration procedure on this card or the Fryer section of the  
Equipment Manual for Troubleshooting Charts and check the following:  
a. Grease filter condition  
b. Cooking oil level  
c. (Gas fryers) Proper placement of seal angle, gravity blade and standoff  
d. (Gas fryers) Air flow, combustion air blower  
e. (Gas fryers) Radiant burner condition  
f. (Electric fryers) Large power plug plugged in properly.  
4. Repeat steps 1 through 3 for each additional vat.  
5. Recovery time check is complete.  
Recovery Check Time (With M2000 Computer only.)  
When  
Monthly  
Note: With the M2000 cooking computer, Recovery Time Checks are performed  
automatically and updated each time the vat temperature rises from 250°F (121°C) to  
above 320°F (160°C).  
Tools  
Paper, pen.  
1. Turn the fry vat OFF by pressing the  
button. The computer should display OFF. The  
computer must be off to enter the programming mode.  
2. Enter the programming mode by pressing the  
display.  
button. Code will show in the left  
1
6
5
2
3. Enter the code  
displays.  
(1652). The most current recovery time will appear in both  
3 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recovery Check Time (With M2000 Computer only.)  
Continued from previous  
page.  
4. Record the recovery time.  
Note: Recovery time should be less than 145 seconds for a gas fryer, and less than 100  
seconds for an electric fryer. If time is less than 145 seconds for gas, or 100 for electric  
fryers, recovery time is acceptable. If the time displayed is greater than the required  
time, refer to the scratch calibration procedure on this card or the Fryer section of the  
Equipment Manual for Troubleshooting Charts and check the following:  
g. Grease filter condition  
h. Cooking oil level  
i. (Gas fryers) Proper placement of seal angle, gravity blade and standoff  
j. (Gas fryers) Air flow, combustion air blower  
k. (Gas fryers) Radiant burner condition  
l. (Electric fryers) Large power plug plugged in properly.  
6. Repeat steps 1 through 3 for each additional vat.  
7. Recovery time check is complete.  
High-Limit Check (With MACC100 Computer only.)  
When  
Monthly  
Note: Conduct this test when fryer will not be needed for about 1 hour, and when the  
cooking oil is due to be changed. Discard the cooking oil after completing this check.  
Tools  
None  
Note: Grease filters must be in place and exhaust fans must be on during entire high-  
limit control check procedure.  
1. Press  
to turn the vat computer “ON” and let cooking oil stabilize at a normal cooking  
light to go OFF.  
temperature, then wait for the  
2. The cooking oil level should cover the temperature and high-limit probes. Add cooking oil if  
necessary.  
Caution: If, after completing both high-limit tests you find only the second high-limit  
operates properly, the vat can be used if it is absolutely necessary, but with extreme care.  
The computer must be replaced immediately after this period of necessity. If the second  
high-limit does not work the vat must NOT be used until the second high-limit has been  
replaced. If the first high-limit feature activates at less than 400°F (204°C), do not  
replace the computer unless it interferes with proper cooking. If the second high-limit  
activates at less than 425°F (218°C), do not replace it unless it prevents you from  
checking the first high-limit feature.  
Note: The high-limit test program allows the operator to test the trip-out temperature of  
the first and second high-limits. The first high-limit feature is a function performed by  
the computer and automatically resets when the cooking oil cools below its trip point of  
400°F (204°C). The second high-limit automatically resets when the cooking oil has  
cooled to 400°F (204°C) or less. To perform the high-limit test, the vat must be  
operating normally and the display reading "HI-LIMIT" on either display for a full- or  
split-vat, depending on the test being performed. Only one side of a split-vat is to be  
checked at a time. The test can be performed any time the vat is turned ON except if  
the vat is in the melt or cooking cycle.  
3. To start the "first high-limit test", press the  
button and the  
button  
simultaneously, then release the  
button, but continue to depress the  
button.  
Result: The vat will heat while the  
button is depressed continuously. The display  
will show the actual temperature during the test. At 410°F (210°C) ±10°F (±5°C), the  
first high-limit feature will trip. The display will show (alternating) HI-1 and the actual  
temperature, i.e. "HI-1-400°F (204°C)" until the vat cools to 400°F (204°C), or less.  
The vat will automatically reactivate below 400°F (204°C).  
4 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
High-Limit Check (With MACC100 Computer only.)  
When
Monthly  
Note: When the display shows "HI-1-412°F (211°C)", or the temperature exceeds 425°F  
(218°C), release the  
button.  
Tools  
None  
4. To start the "second high-limit test", press and hold the  
button. This display will  
show the actual temperature during the test. The mechanical second high-limit will trip  
between 425°F (218°C) and 450°F (232°C).  
Result: When the second high-limit trips, the display will read (alternating) "HI-2" and  
the actual temperature.  
Caution: When display shows "HI-2" or the temperature exceeds 450°F (232°C), release  
the  
Note: The display will continue to read "HI-2" until the fryer has cooked to 400°F  
(204°C) or less and the vat is reactivated by pressing turning the computer OFF for  
30 seconds, then pressing to turn computer ON.  
button.  
,
5. The computer will return to the operating mode and display the cooking program  
previously used, i.e. FR FRIES, PIES, NUGGETS, etc.  
6. High-limit control check is complete.  
7. Repeat same procedure for other vats.  
Caution: If the display shows "HI-2" "BAD", press  
to turn the computer “OFF”.  
Replace the computer immediately.  
When  
Monthly  
High-Limit Check (With Thermostat Controller only.)  
Note: Conduct this test when fryer will not be needed for about 1 hour, and when the  
cooking oil is due to be changed. Discard the cooking oil after completing this check  
Tools  
None.  
Note: Only one side of a split-vat is to be checked at a time.  
Caution: Grease filters must be in place and exhaust fans must be ON during entire high-  
limit control check procedure.  
1. The cooking oil should be at the normal (upper) oil-level line. Add cooking oil if necessary.  
2. Remove the computer probe from the probe holder and replace it with fry vat probe.  
3. Turn the vat power switch to ON and set thermostat knob to its highest setting, and wait for  
heating light to go OFF.  
Caution: If after completing both high-limit tests you find only the second high-limit  
operates properly, the vat can be used if it is absolutely necessary, but with extreme care.  
The controller must be replaced immediately after this period of necessity. If the second  
high-limit does not work, the vat must not be used until the second high-limit has been  
replaced. If the first high-limit feature activates at less than 400°F (204°C), do not  
replace the controller unless it interferes with proper cooking. If the second high-limit  
activates at less than 425°F (218°C), do not replace it unless it prevents you from  
checking the first high-limit feature.  
4. Press and hold "first high-limit" position of the vat high-limit test switch.  
Result: Electrical element or gas burner turns OFF and "TROUBLE" light comes ON.  
Cooking oil temperature should be between 400° and 425°F (204° and 218°C).  
5. Press and hold "second high-limit" position of the vat-limit test switch.  
5 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Continued from previous  
page.  
High-Limit Check (With Thermostat Controller only.)  
Note: When the trouble light comes ON, or the temperature exceeds 425°F (218°C),  
release switch.  
Result: Electrical elements or gas burner turns OFF and the second high-limit will come  
ON. The cooking oil temperature should be between 425° and 450°F (218° and 232°C).  
Caution: When the second high-limit light comes on or the temperature exceeds 450°F  
(232°C), release switch.  
6. Turn the power switch to the “OFF” position. One vat must remain ON to ensure hood  
fan remains ON.  
7. Remove the fry vat probe and reinstall the computer probe into the vat.  
8. Allow cooking oil to cool for one hour before discarding. See statement on discarding.  
9. High-limit check is complete. Repeat procedure for each remaining vat.  
Caution: STATEMENT ON DISCARDING OIL—Hot cooking-oil is dangerous and  
will cause severe skin burns. Handle with extreme caution. When discarding old  
cooking oil, the cooking oil should be drained from the fryer into a cooking oil removal  
cart. The cart should then be taken to a grease barrel and pumped into the grease barrel  
to properly dispose of the old cooking oil.  
When  
Monthly  
High-Limit Check (With MACC100A, M100A, and M100B Computer only.)  
Note: Conduct this test when the fryer will not be needed for about 1 hour, and when the  
cooking oil is due to be changed. Discard the cooking oil after completing this check.  
Tools  
None.  
Note: The cooking oil must be at a high enough level to cover the high-limit probe.  
Note: Grease filters must be in place and exhaust fans must be on during entire high-  
limit control check procedure.  
Note: The high-limit test program allows the operator to test the trip-out temperature of  
the first and second high-limit thermostats. The first high-limit feature is a function  
performed by the computer and automatically resets when the cooking oil cools below  
its trip point of 400°F (204°C). The second high-limit automatically resets when the  
cooking oil has cooled to 400°F (204°C) or less. To perform the high-limit test, the vat  
must be operating normally and the display reading "HI-LIMIT" on either display for a  
full- or split-vat, depending on the test being performed. Only one side of a split-vat is  
to be checked at a time. The test can be performed any time the vat is turned ON  
except if the vat is in the melt or cooking cycle.  
1. Turn the fry vat ON by pressing the  
button (M100B) and allow cooking oil to stabilize at normal cooking temperature. Wait  
for the light to go OFF before proceeding.  
button (MACC100A and M100A), or the  
2. To access the "high-limit test", depress the  
simultaneously in the following sequences:  
and  
(left or right) buttons  
Full-vat:  
and  
button  
Split-vat, left:  
Split-vat, right:  
and Left  
and Right  
buttons  
buttons  
3. To start the "first high-limit test", press and hold the  
"HI-LIMIT".  
button. The display should read  
6 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Continued from previous  
page.  
High-Limit Check (With MACC100A, M100A, and M100B Computer only.)  
Result: The light will illuminate and the display will show the actual temperature of  
the cooking oil. At 410°F (210°C) ± 10°F (6°C), the first high-limit feature will trip.  
The display will show (alternating) "HI-1" and the actual vat temperature.  
Note: When the display shows (alternating) "HI-1" and the temperature or the  
temperature exceeds 425°F (218°C), release the  
button.  
Caution: If the temperature exceeds 425°F (218°C) without a "HI-1" display, the first  
high-limit warning is not functioning properly. Note this defect and continue this  
procedure to test the second high-limit.  
4. To start the "second high-limit test", press and hold the  
button.  
Result: The vat heat light will illuminate and the display will show the actual  
temperature during the test. The mechanical second high-limit should trip between 425°  
and 450°F (218° and 232°C). When the second high-limit trips, the display will read  
(alternating) "HI-2" and the actual temperature.  
(
Caution: When the display shows "HI-2" or the temperature exceeds 470°F (232°C),  
release the  
button.  
Note: The display will continue to read "HI-2" until the fryer has cooled to 400°F  
(204°C) or less and the vat has then been reactivated by turning the computer “OFF”  
then back “ON”. The cooking program previously used will be displayed; i.e., FR  
FRIES, PIES, McNUGGETS, etc.  
Caution: If the display shows "HI-2" "BAD", press the  
(MACC100A and M100A)  
or (M100B) button to turn the computer “OFF”. REPLACE the mechanical second  
high-limit thermostat immediately.  
5. High-limit control check is complete.  
6. Repeat the same procedure for other vats.  
Caution: If after completing both high-limit tests you find only the second high-limit  
operates properly, the vat can be used if it is absolutely necessary, but with extreme care.  
The computer must be replaced immediately after this period of necessity. If the second  
high-limit does not work, the vat must not be used until the second high-limit has been  
replaced. If the first high-limit feature activates at less than 400°F (204°C), do not  
repair or replace the computer or controller unless it interferes with proper cooking. If  
the second high-limit activates at less than 425°F (218°C), do not replace it unless it  
prevents you from checking the first high-limit feature.  
When  
Monthly  
High-Limit Check (With M2000 Computer only.)  
Note: Conduct this test when the fryer will not be needed for about 1 hour, and when the  
cooking oil is due to be changed. Discard the cooking oil after completing this check.  
Tools  
None  
Note: The cooking oil should be at the upper OIL LEVEL line. Add oil if necessary.  
Note: Grease filters must be in place and exhaust fans must be on during entire high-  
limit control check procedure.  
Note: The high-limit test program allows the operator to test the trip-out temperature of  
the first and second high-limit thermostats. The first high-limit feature is a function  
performed by the computer and must be reset by turning the computer OFF, then back  
ON. The second high-limit automatically resets when the cooking oil has cooled to  
below 350°F (177°C) or less.  
7 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
High-Limit Check (With M2000 Computer only.)  
Continued from previous  
page.  
1. Turn the fry vat OFF by pressing the  
button. The computer should display OFF. The  
computer must be off to enter the programming mode.  
2. Enter the programming mode by pressing the  
display.  
button. Code will show in the left  
9
9
9
9
3. Enter the code  
(9999)to check high-limits for a full vat or right side of split  
YZ-  
YZ-  
YZ-  
YZ-  
8
8
8
8
pot. To test the left side of a split pot, enter the code  
(8888).  
VWX  
VWX  
VWX  
VWX  
Note: This test can only be conducted with the oil temperature above 180°F. If the  
shortening/oil temperature is below 180°F, the computer will display too cold.  
4. Hi-Limitshows in the right display (left display for left-side split vat).  
1
1
5. For high-limit test #1, press and hold the right  
channel button if testing the left side of a split pot).  
cook channel button (left  
cook  
6. The heat indicator should illuminate, indicating the fryer is calling for heat.  
7. The right display will alternate between HI-Limitand the oil/shortening temperature until  
the temperature reaches 410°F (210°C). At 410°F (210°C), Hi-1is displayed, alternating  
with the current temperature. The heat indicator goes out, indicating that the fryer is no  
longer calling for heat. High-limit test #1 is complete.  
2
2
8. For high-limit test #2, press and hold the right  
channel button if testing the left side of a split pot).  
cook channel button (left  
cook  
9. The right display will alternate between Hi-Limit and the oil/shortening temperature until  
the mechanical high-limit opens (approximately 425°F (218°C). The right display will then  
show Hi-2.  
10. Failure of high-limit test #2 is indicated by an alternating display of hi-2and bad. Call  
for service immediately if this occurs.  
11. Press  
to clear the test and turn the computer off.  
Caution: If after completing both high-limit tests you find only the second high-limit  
operates properly, the vat can be used if it is absolutely necessary, but with extreme care.  
The computer must be replaced immediately after this period of necessity. If the second  
high-limit does not work, the vat must not be used until the second high-limit has been  
replaced. If the first high-limit feature activates at less than 410°F (204°C), do not  
repair or replace the computer or controller unless it interferes with proper cooking. If  
the second high-limit activates at less than 425°F (218°C), do not replace it unless it  
prevents you from checking the first high-limit feature.  
When  
Quarterly  
Scratch Calibration Check  
(Gas Fryers Only) (Should be done by a qualified service person.)  
Caution: Portions of fryer will be hot during this scratch calibration.  
Note: Conduct this test when fryer will not be needed for about one hour.  
Tools  
Flat blade screwdriver,  
7/16" (13 mm) open-end  
wrench, and multimeter  
(that measures DC  
microamps).  
1. Contact the local gas company or service agency to check the gas pressure out of the  
fryer's gas regulator.  
Result: Gas pressure must be 3.0" W.C. (76 mm W.C.) natural gas or 8.25" W.C. (210  
mm W.C.) propane gas.  
Caution: If the pressure does not meet above requirements the fryer gas valve regulator  
must be adjusted by the service agency to obtain the correct pressure.  
8 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scratch Calibration Check  
Continued from previous  
page.  
2. Remove gas valve vent tube. Clean and replace. See cleaning procedure in service  
manual.  
3. Clean combustion air blower. See the service manual for cleaning procedure.  
4. Conduct recovery test as outlined on this card. The recovery test procedure varies  
dependent upon the controller/computer model of your fryer.  
5. If the vat does not meet the recovery specification, adjust the combustion air blower to  
obtain the proper recovery time.  
COMBUSTION AIR BLOWER ADJUSTMENT  
Note: Use a multimeter that measures DC microamps when making burner air  
adjustments.  
Note: Ensure proper gas pressure is set out of the gas regulator.  
6. Connect the multimeter in series with the white flame sensor wire on the ignitor.  
7. After fryer has completed the melt cycle, allow burner to operate for at least one minute.  
8. Check for a 2.5 to 3.5 microamp reading on the multimeter. This reading should show at  
least 2.5 microamps. Adjust the combustion air-blower intake plate to obtain a  
maximum microamp reading on the multimeter.  
Note: Air adjustment must be made if a blue flame is observed through the burner  
viewing ports, or if there are dark spots on the burner face. After 90 seconds of  
continuous burner operation, the burner should glow bright orange-red. (For proper  
colors, see the "BURNER COLOR COMPARISON CHART" located inside the door of  
the fryer). If flame color is not correct, it is necessary to adjust the combustion air-  
blower air intake-plate.  
9. To adjust the blower intake plate, loosen the locking nut(s) on the intake plate with a small  
adjustable wrench.  
10. Adjust the plate opened or closed to obtain a maximum reading on the multimeter. When  
observing the burner through the viewing ports, an orange-red glow should be seen on the  
face of the burner. The ports are located directly above the spark ignitors.  
11. When a maximum microamp reading and an orange-red glow have been obtained, tighten the  
intake plate locking nut(s) while holding the plate to prevent movement.  
Note: A blue flame observed through the burner viewing ports usually indicates  
insufficient air. Dark spots on the burner face indicate excess air.  
12. Recheck the recovery time as outlined on this card.  
13. If further combustion air adjustments are needed, repeat Steps 9 through 12 until the  
recovery time specification is met.  
14. Repeat Steps 9 through 13 for each vat of the fryer.  
15. Scratch calibration check is complete. Check remaining fryers.  
9 of 9  
© 2000 McDonald’s Corporation  
All Rights Reserved  
819-5432 NOV 05  
Card 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eclipse Fujitsu Ten GPS Receiver AVN52D User Manual
Electro Voice Microphone 652 User Manual
Fisher Price Baby Monitor P1384 User Manual
Fisher Price Baby Toy B8078 User Manual
Fisher Price Bicycle 72639 User Manual
Fishman Water Dispenser LDS9000 User Manual
Frigidaire Washer FWT449GF User Manual
GE Microwave Oven PVM1970 User Manual
GE Water System GXWH35F User Manual
Goodman Mfg Furnace SS GME8 User Manual