Faber Security Camera M1024 User Manual

GenieMonochrome  
Series  
Camera User’s Manual  
Genie Framework 1.20  
M640  
M1024  
M1400  
M1600  
CA-GENM-MUM00  
www.imaging.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
GENIE MONOCHROME SERIES OVERVIEW.....................................................................................5  
DESCRIPTION ............................................................................................................................................5  
Genie Application Advantages..........................................................................................................6  
PRODUCT PART NUMBERS ........................................................................................................................7  
CAMERA PERFORMANCE SPECIFICATIONS ................................................................................................8  
Certifications.....................................................................................................................................9  
SUPPORTED INDUSTRY STANDARDS..........................................................................................................9  
GENIE SENSOR OVERVIEW........................................................................................................................9  
Genie M640-1/2 Specifications.......................................................................................................10  
Genie M640-1/3 Specifications.......................................................................................................11  
Genie M1024 Specifications ...........................................................................................................12  
Genie M1400 Specifications ...........................................................................................................13  
Genie M1600 Specifications ...........................................................................................................14  
APPLICATION DEVELOPMENT OVERVIEW ...............................................................................................15  
Sapera LT Library with optional Processing..................................................................................15  
GenICam Environment ...................................................................................................................15  
INSTALLING THE GENIE CAMERA....................................................................................................17  
WARNING! (GROUNDING INSTRUCTIONS)...............................................................................................17  
GIGE NETWORK ADAPTER GUIDELINE ...................................................................................................17  
Supported Network Configurations ................................................................................................17  
Using Genie with Ethernet Switches...............................................................................................17  
Using Genie with a VLAN Ethernet Switch.....................................................................................18  
INSTALLATION OVERVIEW & PREPARATIONS .........................................................................................18  
Network and Computer Overview...................................................................................................18  
Installation Overview......................................................................................................................19  
SAPERA LT LIBRARY INSTALLATION......................................................................................................19  
GENIE CD PACKAGE INSTALLATION.......................................................................................................20  
Procedure........................................................................................................................................20  
GigE Server Verification.................................................................................................................20  
CONNECT THE GENIE CAMERA ...............................................................................................................21  
Connectors......................................................................................................................................21  
Status LED Codes ...........................................................................................................................22  
Typical LED States on Power Up ........................................................................................................... 23  
Genie IP Configuration Sequence ..................................................................................................23  
GigE Server Status..........................................................................................................................23  
OPTIMIZING THE NETWORK ADAPTER USED WITH GENIE .......................................................................24  
Increasing Adapter Buffers and Jumbo Frames .............................................................................24  
Select NIC Advanced Configuration Properties...................................................................................... 25  
Receive Descriptors ................................................................................................................................ 25  
Jumbo Frames ......................................................................................................................................... 26  
Running the Network Configuration Tool.......................................................................................26  
UPDATING GENIE FIRMWARE..................................................................................................................27  
QUICK TEST WITH CAMEXPERT ..............................................................................................................29  
About the User-Defined Camera Name ..........................................................................................30  
OPERATIONAL REFERENCE................................................................................................................31  
CAMERA AND SENSOR INFORMATION .....................................................................................................31  
Genie Monochrome Series-GigE Vision Camera  
Contents 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Access Via CamExpert....................................................................................................................31  
Power-up Configuration.......................................................................................................................... 32  
Camera Information via Sapera LT or GenICam Applications......................................................33  
SENSOR CONTROLS.................................................................................................................................34  
Sensor Parameters: Controls Via CamExpert................................................................................34  
Gain and Black Level Controls.......................................................................................................36  
Gain and Offset Control via Sapera LT or GenICam Applications................................................36  
Partial Scan—Window ROI ............................................................................................................37  
Window ROI Control via Sapera LT or GenICam Applications.....................................................39  
CamExpert Image Buffer and ROI Parameters ..............................................................................40  
Binning............................................................................................................................................41  
Binning Control via Sapera LT or GenICam Applications.............................................................42  
TRIGGER MODES.....................................................................................................................................42  
EXPOSURE CONTROLS.............................................................................................................................43  
Free-running Programmable Exposure..........................................................................................43  
External Trigger Programmable Exposure ....................................................................................44  
External Trigger Level-controlled Exposure ..................................................................................45  
Exposure Controls via Sapera LT or GenICam Applications.........................................................45  
SYNCHRONIZATION TIMING ....................................................................................................................46  
Synchronous Mode..........................................................................................................................46  
Reset Mode......................................................................................................................................47  
Synchronization Mode via Sapera LT or GenICam Applications...................................................47  
CAMEXPERT I/O CONTROLS DIALOG .....................................................................................................48  
GENERAL INPUTS ....................................................................................................................................49  
External Input Signal Opto-coupler & Debounce Circuit ..............................................................49  
General Inputs: Settings Via CamExpert........................................................................................49  
Input Controls via Sapera LT or GenICam Applications ...............................................................50  
STROBE AND GENERAL OUTPUTS............................................................................................................51  
General Outputs: Settings via CamExpert......................................................................................51  
Open and Close Output Settings ............................................................................................................. 52  
Strobe On Start of Exposure Event Mode ............................................................................................... 52  
Pulse On Valid Trigger Event Mode....................................................................................................... 53  
Pulse On Invalid Trigger Event Mode..................................................................................................... 53  
Pulse On Start of Readout Event Mode................................................................................................... 54  
Pulse On End of Readout Event Mode.................................................................................................... 54  
Pulse On End of Acquisition Event Mode............................................................................................... 55  
Pulse On Input 1 or Input 2 Event Modes ............................................................................................... 55  
Output Control via Sapera LT or GenICam Applications ..............................................................56  
GENIE PROCESSING FEATURES................................................................................................................56  
Lookup Table (LUT) .......................................................................................................................56  
LUT Control via Sapera LT or GenICam Applications..................................................................57  
Flat Field (Image Shading) Correction ..........................................................................................58  
Flat Field Correction Calibration Procedure ........................................................................................... 58  
Using Flat Field Correction..................................................................................................................... 60  
Flat Field Correction Control via Sapera LT or GenICam Applications.......................................60  
Image Flip.......................................................................................................................................61  
Internal Image Test Patterns ..........................................................................................................62  
Test Image Select via Sapera LT or GenICam Applications...........................................................63  
EVENTS...................................................................................................................................................63  
Sapera Callbacks ............................................................................................................................63  
Event Selection via GenICam Applications ....................................................................................64  
NETWORK CONTROLS & GIGE VISION PARAMETERS .............................................................................65  
CamExpert GigE Vision Parameters..............................................................................................65  
Network Controls via Sapera LT or GenICam Applications ..........................................................66  
GENIE POWER-UP CONFIGURATION ........................................................................................................67  
Power-up Control via Sapera LT or GenICam Applications..........................................................68  
2 Contents  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAPERA SUPPORTED FEATURES LIST ......................................................................................................68  
Accessing Features with Sapera++ LT ..........................................................................................68  
Feature Type STRING.....................................................................................................................69  
Feature Type ENUM.......................................................................................................................69  
Feature Type INT32........................................................................................................................71  
Feature Type BOOL........................................................................................................................72  
Feature Interdependence Diagrams ...............................................................................................72  
Trigger Enable - TRUE........................................................................................................................... 73  
Trigger Enable - FALSE ......................................................................................................................... 73  
Output Selector........................................................................................................................................ 74  
Vertical Binning...................................................................................................................................... 74  
Horizontal Binning.................................................................................................................................. 74  
Pixel Format............................................................................................................................................ 75  
Network Configuration Mode ................................................................................................................. 75  
NETWORK TOOLS...................................................................................................................................77  
IP CONFIGURATION MODE DETAILS .......................................................................................................77  
Link-Local Address (LLA)...............................................................................................................77  
DHCP (Dynamic Host Configuration Protocol).............................................................................78  
Persistent IP....................................................................................................................................78  
NETWORK CONFIGURATION TOOL ..........................................................................................................79  
Quick Genie Network Configuration ..............................................................................................79  
System Information and Configuration...........................................................................................80  
Network Card Information and Configuration ...............................................................................81  
Recovering a Camera with an Unknown Persistent IP...................................................................82  
SAPERA GIGE SERVER DETAILS .............................................................................................................83  
Creating a Status Report.................................................................................................................84  
SAPERA CAMEXPERT GUIDE..............................................................................................................85  
USING CAMEXPERT WITH GENIE MONOCHROME CAMERAS ...................................................................85  
CamExpert Panes............................................................................................................................86  
CamExpert LUT Controls...............................................................................................................87  
TECHNICAL SPECIFICATIONS............................................................................................................89  
MECHANICAL SPECIFICATIONS ...............................................................................................................89  
CONNECTORS..........................................................................................................................................90  
12-Pin Hirose Connector Signal Details ........................................................................................90  
Genie Signal Electrical Details.......................................................................................................91  
External Inputs ........................................................................................................................................ 91  
External Outputs...................................................................................................................................... 92  
RJ45 LAN Ethernet Connector Details...........................................................................................92  
CAMERA STATUS LED............................................................................................................................93  
OPTICAL CONSIDERATIONS.....................................................................................................................93  
Illumination.....................................................................................................................................93  
Light Sources ..................................................................................................................................93  
Filters..............................................................................................................................................94  
Lens Modeling.................................................................................................................................94  
Magnification and Resolution.........................................................................................................94  
SENSOR HANDLING INSTRUCTIONS.........................................................................................................95  
Electrostatic Discharge and the CCD Sensor.................................................................................95  
Protecting Against Dust, Oil and Scratches ...................................................................................95  
Cleaning the Sensor Window..........................................................................................................96  
Environment....................................................................................................................................96  
RUGGEDIZED RJ45 ETHERNET CABLES ..................................................................................................97  
COMPUTER REQUIREMENTS FOR GENIE CAMERAS..................................................................................98  
Host PC System...............................................................................................................................98  
Genie Monochrome Series-GigE Vision Camera  
Contents 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ethernet Switch Requirements ........................................................................................................98  
Ethernet to Fiber-Optic Interface Requirements ............................................................................99  
EC & FCC DECLARATION OF CONFORMITY.........................................................................................100  
TROUBLESHOOTING............................................................................................................................101  
OVERVIEW ............................................................................................................................................101  
Problem Type Summary................................................................................................................101  
INSTALLATION ISSUES AND FUNCTIONAL PROBLEMS............................................................................103  
GigE Server Warning Example 1a: IP error with multiple NICs .................................................103  
GigE Server Warning Example 1b: IP error with multiple NICs .................................................104  
GigE Server Warning Example 2: Subnet Mask or IP error ........................................................105  
GigE Server Warning Example 3: Filter Driver (CorSnid) Disabled ..........................................105  
DEVICE AVAILABLE WITH OPERATIONAL ISSUES..................................................................................106  
Firmware Updates ........................................................................................................................106  
Power Failure During a Firmware Update–Now What? .............................................................107  
Streaming Error: No Acquisition with a Timeout Message..........................................................107  
Disabling Windows Firewall................................................................................................................. 107  
Test a Genie Using Internal Test Patterns....................................................................................109  
Cabling and IP Configuration Issues ...........................................................................................109  
Streaming Video (grab) Issues......................................................................................................109  
Grab Remains Black.............................................................................................................................. 110  
Grab has Random Bad Data or Noise.................................................................................................... 110  
Grab has Random Bad Data or Noise – Case 1..................................................................................... 110  
Grab has Random Bad Data or Noise – Case 2..................................................................................... 111  
Grab has Random Bad Data or Noise – Case 3..................................................................................... 111  
Laptop Computer Networking Issues............................................................................................111  
Configuration Recommendations with Laptops .................................................................................... 112  
Problems when Changing the Laptop NIC............................................................................................ 112  
Problems with Disconnecting NICs ...................................................................................................... 113  
Ethernet Switch Issues ..................................................................................................................113  
Multiple Camera Issues ................................................................................................................113  
Camera Exposure Issues...............................................................................................................114  
Verifying Network Parameters......................................................................................................115  
VPN Driver Interference...............................................................................................................115  
DALSA CONTACT INFORMATION....................................................................................................117  
GENIE SALES INFORMATION .................................................................................................................117  
GENIE TECHNICAL SUPPORT .................................................................................................................118  
GLOSSARY OF TERMS.........................................................................................................................119  
INDEX........................................................................................................................................................123  
4 Contents  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Genie Monochrome Series  
Overview  
Description  
The Genie monochrome camera family form a series of affordable, easy to use digital cameras specifically  
engineered for industrial imaging applications. Genie cameras combine standard gigabit Ethernet technology with  
the DALSA Trigger-to-Image-Reliability framework to dependably capture and transfer images from the camera to  
the host PC.  
All Genie cameras are supported by DALSA Sapera™ LT software libraries featuring CamExpert for simplified  
camera set-up and configuration. Sapera LT is field proven in thousands of robust industrial applications. Hardware  
independent, Sapera LT delivers the same reliable performance regardless of the image acquisition device being  
used. This unique feature allows OEM’s to start using the Genie without re-writing applications developed for  
DALSA frame grabbers. In addition, Sapera LT includes powerful diagnostics and setup utilities for application  
development, custom camera configurations and system deployment.  
Genie Monochrome Series-GigE Vision Camera  
Genie Monochrome Series Overview 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie Application Advantages  
Compact, rugged design  
GigE Vision 1.0 compliant  
Gigabit Ethernet (GigE) interconnection to a computer via standard CAT5e or CAT6 cables  
Connection to the host computer NIC through a GigE network switch  
Available in variety of resolutions, each supporting 8-bit or 10-bit acquisitions  
Lookup table pre-processing  
Real-time shading correction (i.e. Flat Field processing)  
Horizontal Flip function  
Supports several trigger modes for image capture control  
2 opto-isolated inputs  
2 opto-isolated outputs  
Native Trigger-to-Image Reliability design framework  
Visual status LEDs on camera back plate  
1µs internal timer to timestamp images and events  
Supported by Sapera™ LT software libraries  
6 Genie Monochrome Series Overview  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Product Part Numbers  
This manual covers the five monochrome Genie models summarized below. See "Camera Performance  
Specifications" on page 8 for each Genie model.  
fps  
(full frame)  
Product Number  
Camera  
Sensor Size Resolution  
Pixel size (µm)  
CR-GEN0-M6400  
CR-GEN3-M6400  
CR-GEN0-M1020  
CR-GEN0-M1400  
CR-GEN0-M1600  
Genie M640-1/2  
Genie M640-1/3  
Genie M1024  
Genie M1400  
Genie M1600  
1/2 in  
1/3 in  
1/3 in  
1/2 in  
1/1.8 in  
640 x 480  
9.9 x 9.9  
64  
64  
20  
15  
12  
640 x 480  
7.4 x 7.4  
1024 x 768  
1360 x 1024  
1600 x 1200  
4.65 x 4.65  
4.65 x 4.65  
4.40 x 4.40  
Software  
Product Number  
Genie Framework composed of the Sapera network Imaging Package, Genie Imaging  
Driver and latest Genie Firmware.  
Included with Genie and required  
Sapera Runtime including CamExpert  
Included and installed if desired  
Embedded within Genie  
OC-SL00-0000000  
GenICam™ support (XML camera description file)  
Sapera LT version 6.00 or later (sold separately):  
Provides everything you will need to develop imaging applications  
Sapera documentation in compiled HTML help, and Adobe Acrobat® (PDF) formats  
Sapera Processing Imaging Development Library (sold separately):  
Includes over 600 optimized image processing routines.  
Contact Sales at  
DALSA  
Genie Cables & Accessories (sold separately)  
Product number  
Genie I/O and Power breakout cable (Hirose to Euroconnector)  
CA-GENC-IOP00  
CA-GENA-BRA00  
Tripod mount bracket (mount to Genie top or bottom—provides ¼-20 socket)  
Industrial type CAT 6 cable assembly:  
Molded shroud with top/bottom thumbscrews on one end with standard Ethernet RJ45  
clip on other. Available in various lengths. See "Ruggedized RJ45 Ethernet Cables"  
on page 97.  
Genie Monochrome Series-GigE Vision Camera  
Genie Monochrome Series Overview 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Camera Performance Specifications  
Specifications for each available sensor are listed after the general Genie camera specifications.  
Camera Controls  
Synchronization Modes  
Free running and Triggered  
Synchronous and Reset mode  
Software trigger (through Ethernet)  
Exposure Modes  
Trigger Input  
Programmable (1µs granularity)  
Pulse controlled  
Opto-isolated, 2V to 12V typical, 2mA min.  
Debounce range from 1 µs up to 255 µs  
Strobe Output  
Output opto-isolated: Aligned to the start of exposure with a  
programmable delay, duration and polarity  
Features  
LUT  
8-bit / 10-bit  
Flip  
Real-time horizontal flip  
Binning  
Timestamp  
Test image  
User settings  
Horizontal (2 pixel) and Vertical (2 line)  
1µs internal timer to timestamp images and events  
Internal pattern generator  
Select factory default or one user camera configuration  
Optical Interface  
Back Focal Distance—C mount  
Mechanical Interface  
17.52 mm  
Camera Size  
Mass  
29(H) x 44(W) x 67(L) in mm, ( see Mechanical Specifications )  
< 125g (no lens)  
12 pin male Hirose  
RJ45  
Power connector  
Ethernet connector  
Electrical Interface  
Input Voltage  
+11 to +13 Volts DC, ( over voltage–reverse voltage protected )  
Power Dissipation  
Operating Temperature  
Output Data Configuration  
Data and Control  
< 4W  
0 to 45°C  
Gigabit Ethernet (IEEE 802.3)  
GigE Vision compliant at 1000 or 100 Mbps  
8 Genie Monochrome Series Overview  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Certifications  
EN55022, class A, Radio Disturbance Characteristics  
CE  
EN61000-4-2,  
EN61000-4-3,  
EN61000-4-4,  
EN61000-4-6,  
Electrostatic discharge immunity test  
Radiated, radio-frequency, electromagnetic field immunity test  
Electrical fast transient/burst immunity test  
Immunity to conducted disturbances, induced by radio-frequency fields  
Part 15, class A  
FCC  
Compliancy as per European directive 2002/95/EC  
(applies to camera part numbers CR-GENx-xxxxx)  
RoHS  
Supported Industry Standards  
Genie cameras are 100% compliant with the GigE Vision 1.0  
specification which defines the communication interface protocol  
used by any GigE Vision device. For more information see:  
Genie cameras implement a superset of the GenICam™  
specification which defines device capabilities. This description  
takes the form of an XML device description file respecting the  
syntax defined by the GenApi module of the GenICam™  
specification. For more information see www.genicam.org.  
Genie Sensor Overview  
Each sensor description below provides a specification table and response graphic. The graph describes the sensor  
response to different wavelengths of light (excluding lens and light source characteristics). Visible light spans  
wavelengths between about 390 - 780 nanometers. Wavelengths below 390 nm are termed ultra-violet while those  
above 780 nm. are termed infra-red. The peak response is around 500 nanometers typical for each sensor model,  
corresponding to a shade of blue-green.  
Genie Monochrome Series-GigE Vision Camera  
Genie Monochrome Series Overview 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie M640-1/2 Specifications  
Item / Feature  
Specification  
Imager Format  
Full frame interline CCD area scan with square pixel  
Sony ICX414AL  
Sensor  
Resolution  
640 x 480 pixels  
Minimum Frame Rate (free-running)  
0.1 fps (one frame every 10 seconds)  
Maximum Frame Rate (free-running) 64 fps  
Maximum Exposure  
Pixel Size  
1 / frame rate - 100μs  
9.9µm x 9.9µm  
Pixel Format  
Shutter  
8-bit, 10-bit  
Full frame electronic shutter  
-6dB to +12dB  
Gain Range  
Genie M640-1/2 Responsivity  
10 Genie Monochrome Series Overview  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie M640-1/3 Specifications  
Item / Feature  
Specification  
Imager Format  
Full frame interline CCD area scan with square pixel  
Sony ICX424AL  
Sensor  
Resolution  
640 x 480 pixels  
Minimum Frame Rate (free-running)  
0.1 fps (one frame every 10 seconds)  
Maximum Frame Rate (free-running) 64 fps  
Maximum Exposure  
Pixel Size  
1 / frame rate - 100μs  
7.4µm x 7.4µm  
Pixel Format  
Shutter  
8-bit, 10-bit  
Full frame electronic shutter  
-6dB to +12dB  
Gain Range  
Genie M640-1/3 Responsivity  
Genie Monochrome Series-GigE Vision Camera  
Genie Monochrome Series Overview 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie M1024 Specifications  
Item / Feature  
Specification  
Imager Format  
Full frame interline CCD area scan with square pixel  
Sony ICX204AL  
Sensor  
Resolution  
1024 x 768 pixels  
Minimum Frame Rate (free-running)  
0.1 fps (one frame every 10 seconds)  
Maximum Frame Rate (free-running) 20 fps  
Maximum Exposure  
Pixel Size  
1 / frame rate - 100μs  
4.65μm (H) × 4.65μm (V)  
8-bit, 10-bit  
Pixel Format  
Shutter  
Full frame electronic shutter  
-6dB to +12dB  
Gain Range  
Genie M1024 Responsivity  
12 Genie Monochrome Series Overview  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie M1400 Specifications  
Item / Feature  
Specification  
Imager Format  
Full frame interline CCD area scan with square pixel  
ICX267AL  
Sensor  
Resolution  
1360 x 1024 pixels  
Minimum Frame Rate (free-running)  
0.1 fps (one frame every 10 seconds)  
Maximum Frame Rate (free-running) 15 fps  
Maximum Exposure  
Pixel Size  
1 / frame rate - 100μs  
4.65µm (H) x 4.65µm (V)  
8-bit, 10-bit  
Pixel Format  
Shutter  
Full frame electronic shutter  
-6dB to +12dB  
Gain Range  
Genie M1400 Responsivity  
Genie Monochrome Series-GigE Vision Camera  
Genie Monochrome Series Overview 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie M1600 Specifications  
Item / Feature  
Specification  
Imager Format  
Full frame interline CCD area scan with square pixel  
Sony ICX274AL  
Sensor  
Resolution  
1600 x 1200 pixels  
Minimum Frame Rate (free-running)  
0.1 fps (one frame every 10 seconds)  
Maximum Frame Rate (free-running) 12 fps  
Maximum Exposure  
Pixel Size  
1 / frame rate - 100μs  
4.40μm (H) × 4.40μm (V)  
8-bit, 10-bit  
Pixel Format  
Shutter  
Full frame electronic shutter  
-6dB to +12dB  
Gain Range  
Genie M1600 Responsivity  
14 Genie Monochrome Series Overview  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Application Development Overview  
Sapera LT Library with optional Processing  
Sapera LT is a powerful development library for image acquisition and control. Sapera LT provides a single API  
across current and future DALSA hardware. Sapera LT delivers a comprehensive feature set including program  
portability, versatile camera controls, flexible display functionality and management, plus easy to use application  
development wizards.  
Sapera Processing is a comprehensive set of C++ classes for image processing and analysis. Sapera Processing  
offers highly optimized tools for image processing, blob analysis, search (pattern recognition), OCR and barcode  
decoding.  
The following is a Sapera application functional block diagram.  
Sapera  
CamExpert  
Application  
Sapera LT SDK  
Sapera LT  
Network  
Genie  
Framework  
Genie Driver  
Configuration Tool  
Control  
GigE Server  
Images  
Sapera Network  
Imaging Driver  
GigE DLL  
GVCP - GigE Vision Control Protocol  
GVSP – GigE Vision Stream Protocol  
NIC  
Ethernet  
cable  
Genie  
GenICam Environment  
Genie cameras implement the GenICam™ specification which define the device capabilities. The GenICam XML  
device description file is embedded within Genie firmware allowing GenICam applications to know Genie  
capabilities immediately after connection. For more information about the GenApi module of the GenICam™  
specification see www.genicam.org.  
Genie Monochrome Series-GigE Vision Camera  
Genie Monochrome Series Overview 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
16 Genie Monochrome Series Overview  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Genie Camera  
Warning! (Grounding Instructions)  
Static electricity can damage electronic components. Please discharge any static electrical charge by touching a  
grounded surface, such as the metal computer chassis, before performing any hardware installation.  
If you do not feel comfortable performing the installation, please consult a qualified technician.  
GigE Network Adapter Guideline  
If the computer to be used with the Genie camera does not have a Gigabit network adapter or second built in Gigabit  
NIC, a PCI bus Gigabit NIC needs to be installed. Typically under Windows XP the PCI Gigabit NIC is recognized  
automatically when Windows boots. An example of a high performance NIC is the Intel PRO/1000 MT adapter.  
Review the NIC documentation concerning any special driver required for Windows. Install the PCI bus Gigabit  
NIC as described by the NIC manufacture's documentation.  
The Genie camera has been tested with a variety of Gigabit network adapters, both built into the system  
motherboard and as third party PCI adapters.  
Supported Network Configurations  
The Genie obtains an IP address using the Link Local Address (LLA) or DHCP, by default. If required, a persistent  
IP address can be assigned (see "Running the Network Configuration Tool" on page 26).  
The LLA method automatically assigns the Genie with a randomly chosen address on the 169.254.xxx.xxx subnet.  
After an address is chosen, the link-local process sends an ARP query with that IP onto the network to see if it is  
already in use. If there is no response, the IP is assigned to the device, otherwise another IP is selected, and the ARP  
is repeated. Note that LLA is unable to forward packets across routers.  
Alternatively, if a DHCP server is present on the network, the Genie is going to issue a DHCP request asking for an  
IP address. The DHCP server will then provide the Genie an IP address.  
Using Genie with Ethernet Switches  
Examples where a Gigabit Ethernet switch would be used are:  
Multiple Genie cameras are controlled by one computer and a single NIC (running multiple instances of  
CamExpert as an example of the control program).  
Multiple Genie cameras are individually controlled by multiple computers, all located on the same subnet.  
In these cases the Ethernet switch is a transparent device. The device discovery process finds all Genie cameras, and  
presents them as ready to be controlled by an application such as CamExpert.  
Genie Monochrome Series-GigE Vision Camera  
Installing the Genie Camera 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using Genie with a VLAN Ethernet Switch  
An Ethernet switch supporting VLAN (Virtual Local Area Network) allows multiple isolated subnets to exist on the  
same switch.  
Within each VLAN group, the Genie camera and controlling computer will behave identically as if connected to a  
simple Ethernet switch. But each VLAN group is isolated from each other, Therefore a Genie in one VLAN group  
is never seen by a computer on a different VLAN group.  
VLAN Ethernet Switches support configuration as Port-based or TAG VLAN groups. Port-based groups are  
typically easier to configure. Review your Ethernet switch manual for information on its factory default VLAN  
settings and configuration method.  
Installation Overview & Preparations  
The Genie camera installation generally follows the sequence described below. Detailed installation instructions  
follow this overview.  
Network and Computer Overview  
Genie needs to connect to a computer with a GigE network adapter, either built in on the computer  
motherboard or installed as a third party PCI adapter.  
Laptop computers with built in GigE network adapters may still not be able to stream full frame rates from  
Genie, especially when on battery power. Thorough testing is required with any laptop computer to determine  
the maximum frame rate possible (see "Laptop Computer Networking Issues" on page 111).  
Genie also can connect through a Gigabit Ethernet switch. When using VLAN groups, the Genie and  
controlling computer must be in the same group (see "Using Genie with a VLAN Ethernet Switch" on page 18).  
If Genie is to be used in a Sapera development environment, Sapera LT needs to be installed, either before or  
after the Genie software package. If Genie will be used in a GenICam™ environment, Sapera or Sapera runtime  
is not required and you need to follow the installation instructions of the third party GenICam compliant  
package.  
Install the Genie Framework software package if not using a third party GenICam compliant package. Also  
install Sapera Run-time with CamExpert to control the Genie.  
The Windows Firewall exceptions feature is automatically configured to allow the Sapera GigE Server to pass  
through the firewall.  
Computers with VPN software (virtual private network) may need to have the VPN driver disabled in the NIC  
properties. This would be required only on the NIC used with the Genie. Testing by the user is required.  
18 Installing the Genie Camera  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation Overview  
Inspect all cables and connectors prior to their use. Do not use faulty cables or connectors to avoid camera  
damage.  
Before connecting power to the camera, test all power supplies. Power supplies must meet the requirements  
defined in section "Genie Signal Electrical Details" on page 91. Apply power to the camera.  
Connect Genie to the computer GigE network adapter or to the Ethernet switch via a CAT5e or CAT6 Ethernet  
cable. Note: cable should not be less than 1 meter (3 feet) long or more than 100 meters (328 feet) long.  
Check the diagnostic LED which will be initially red then switch to flashing blue while waiting for IP  
configuration. See "Status LED Codes" on page 22 for Genie LED display descriptions.  
Look at the small camera icon added to the Windows tray (next to the clock). Ensure the Genie camera has  
been found (right click the icon and select Status).  
A new Genie installation typically requires a firmware update. See the procedure "Updating Genie Firmware"  
on page 27.  
Use CamExpert (installed either with Sapera or Sapera runtime) to test the installation of the Genie camera. Set  
the Genie to internal test pattern. See "Sapera CamExpert Guide" on page 85.  
Set up the other components of the imaging system such as light sources, camera mounts, optics, encoders,  
trigger sources, etc. Test with CamExpert.  
Sapera LT Library Installation  
Note: to install Sapera LT and the Genie device driver, logon to the workstation as an administrator or with an  
account that has administrator privileges.  
When Sapera application development is performed on the same computer that the Genie is connected to, the Sapera  
Development Library (version 6.0 or later) must be installed. Else, Sapera LT is not required to control the Genie  
camera.  
Insert the DALSA Sapera CD-ROM. If AUTORUN is enabled on your computer, the DALSA installation  
menu is presented.  
If AUTORUN is not enabled, use Windows Explorer and browse to the root directory of the CD-ROM.  
Execute launch.exe to start the DALSA installation menu and install the required Sapera components.  
The installation program will prompt you to reboot the computer.  
Continue with the Genie CD Package Installation described next.  
Refer to Sapera LT User’s Manual concerning application development with Sapera.  
Genie Monochrome Series-GigE Vision Camera  
Installing the Genie Camera 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie CD Package Installation  
The Genie Framework software package and Sapera runtime provides all components required to control the Genie  
with the supplied CamExpert tool. Genie Framework software components include the Network Imaging driver, the  
Sapera GigE server, and CamExpert (if Sapera LT library is not installed).  
Note: If Sapera application development is required, install Sapera (6.0 or later) as described in the previous  
section.  
Procedure  
Insert the DALSA Genie CD-ROM. If AUTORUN is enabled on your computer, the Genie installation menu is  
presented.  
If AUTORUN is not enabled, use Windows Explorer and browse to the root directory of the CD-ROM.  
Execute launch.exe to start the installation menu and install the Genie software components.  
Click to install the Genie Framework Software which includes the Network Imaging driver, and the Sapera  
GigE server.  
The procedure will prompt for acceptance of the installation folder for the Genie files.  
If desired, click to install Sapera LT run-time which includes CamExpert. Follow the on screen prompts and  
reboot when the installation is complete.  
GigE Server Verification  
After a successful Genie software package installation, the GigE Server icon is visible in the desktop taskbar tray  
area. The Genie camera must be on the same subnet as the NIC to be recognized by the GigE Server.  
Device Available  
Device IP Error  
Device Not Available  
GigE Server  
Tray Icon:  
The GigE server tray icon  
when the Genie device is  
found. It will take a few  
seconds for the GigE Server to  
refresh its state after the Genie  
has obtained an IP address.  
The GigE server tray icon  
shows a warning when a device GigE server tray icon when the  
is connected but there is some  
type of IP error.  
A red X will remain over the  
Genie device is not found. This  
indicates a major network  
issue.  
If you place your mouse cursor on this icon, the GigE Server will display the number of GigE Vision devices found  
by your PC. Right click the icon and select status to view information about those devices. See "Running the  
Network Configuration Tool" on page 26 and "Troubleshooting" on page 101for more information.  
20 Installing the Genie Camera  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connect the Genie Camera  
Connect a power supply to the Genie camera and an Ethernet cable from the Genie to the host computer. Once  
communication with the host computer is started the automatic IP configuration sequence will assign an LLA IP  
address as described in section "Genie IP Configuration Sequence" on page 23, or a DHCP IP address if a DHCP  
server is present on your network. The factory defaults for Genie is Persistent IP disabled and DHCP enabled with  
LLA always enabled as per the GigE Vision specification. For additional information see "IP Configuration Mode  
Details" on page 77. See the next section "Connectors" on page 21 for an overview of the Genie interfaces.  
Connectors  
The Genie has only two connectors:  
A single RJ45 Ethernet connector for control and video data transmitted to/from the host computer Gigabit  
NIC. See "Ruggedized RJ45 Ethernet Cables" on page 97 for secure cables.  
A single 12-pin Hirose male connector for camera power plus trigger, strobe and general I/O signals. The  
suggested female cable mating connector is Hirose model HR10A-10P-12S.  
The Genie has one multicolor LED to provide a simple visible indication of camera state (see figure below and  
section "Status LED Codes" on page 22). Additionally the RJ45 has two LEDs for network status conditions.  
The following figure of the Genie back end shows connector and LED locations. See "Mechanical Specifications"  
on page 89 for details on the Genie connectors and camera mounting dimensions.  
Genie – Rear View  
Genie Monochrome Series-GigE Vision Camera  
Installing the Genie Camera 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Status LED Codes  
The camera is equipped with a LED to display the operational status of the camera. When more than one condition  
is active, the LED color indicates the condition with the highest priority (such as an acquisition in progress has more  
priority than a valid IP address assignment). The following table summarizes the LED states and corresponding  
camera status.  
LED State  
Definition  
LED is off  
No power to the camera  
Camera not initialized  
Steady Red  
Slow Flashing Red  
Fast Flashing Red  
Slow Flashing Blue  
Fast Flashing Blue  
Steady Blue  
Camera initialization problem  
Camera is too hot  
Waiting for an IP address  
Ethernet cable disconnected (no link)  
IP address assigned;  
no application connected to the camera  
Steady Green  
Application connected  
Slow Flashing Green  
Fast Flashing Green  
Triggered acquisition in progress  
Free-running acquisition in progress  
Once the Genie has its RJ45 connected to a network, the Status LED will turn to steady blue when the IP address is  
assigned. Only at this time will it be possible by the GigE Server or any application to communicate with the  
camera.  
Note: Even if the Genie has obtained an IP address, it might be on a different subnet than the NIC it is attached to.  
Therefore, if the Genie LED is blue but an application such as CamExpert can not see it, this indicates a network  
configuration problem.  
22 Installing the Genie Camera  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Typical LED States on Power Up  
The following LED sequence occurs when the Genie is powered up connected to a network with installed Genie  
Framework software.  
Red  
power connected  
Flashing Blue  
waiting for IP  
Blue  
IP assigned  
Green  
application  
connected  
Genie IP Configuration Sequence  
The Genie IP (Internet Protocol) Configuration sequence to assign an IP address is executed automatically on  
camera power-up or when connected to a network. As a GigE Vision compliant device, Genie attempts to assign an  
IP address as follows.  
For any GigE Vision device, the IP configuration protocol sequence is:  
Persistent IP (if enabled)  
DHCP (if a DHCP server is present)  
Link-Local Address (always enabled)  
The factory defaults for Genie is Persistent IP disabled and DHCP enabled with LLA always enabled as per the  
GigE Vision specification. For additional information see "IP Configuration Mode Details" on page 77.  
GigE Server Status  
Once the Genie is assigned an IP address (its Status LED is steady blue) the GigE server tray icon will not have a  
red X through it, indicating that the Genie device was found. It might take a few seconds for the GigE Server to  
refresh its state after the Genie has obtained an IP address.  
Right-click the GigE Server tray icon to open the following menu.  
Click on Status to open a window listing all devices connected to the host system. Each GigE device is listed by  
name along with important information such as the assigned IP address and device MAC address. The screen shot  
below shows a connected Genie with no networking problems.  
Genie Monochrome Series-GigE Vision Camera  
Installing the Genie Camera 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
In the event that the device is physically connected, but the Sapera GigE Server icon is indicating that the connected  
device is not recognized, click Scan Network to restart the discovery process. Note that the GigE server  
periodically scans the network automatically to refresh its state. See "Troubleshooting" on page 101 for network  
problems.  
Optimizing the Network Adapter used with Genie  
Most Gigabit network interface controllers (NIC) allow user modifications to parameters such as Adapter Buffers  
and Jumbo Frames. These should be optimized for use with the Genie during the installation.  
Increasing Adapter Buffers and Jumbo Frames  
Adapter Buffers (receive descriptors): Under certain conditions the host PC system CPU may be very busy with  
tasks other than the imaging application. Incoming image packets remain in the PC memory allocated to store  
packets instead of immediately being copied into the image buffer. By increasing the NIC host buffers, more  
incoming image packets can be stored by the NIC before it must start discarding them. This provides more time for  
the PC to switch tasks and move image packets to the image buffer.  
Not all network boards allow increasing their buffer count and even among those that do, such as the Intel NIC,  
different versions will have different maximum receive descriptor values. Refer to the NIC user documentation for  
details on configuring this parameter. The procedure in this section shows how to increase the number of packet  
buffers for one version of Intel network adapter.  
Jumbo Frames: With good gigabit Ethernet connections with minimal packet resend conditions, host computer  
performance can be further improved by increasing the data packet size. Each streaming video packet causes an  
interrupt in the host computer. Therefore increasing the packet size reduces the CPU usage percentage required to  
handle video data from Genie.  
Before the Genie is configured to use larger data packets, the NIC used with the Genie must be configured to allow  
Jumbo Frames. The procedure in this section describes increasing the size of Jumbo Frames for one version of Intel  
network adapter.  
The screenshot below shows that the Genie device was found and there is no IP conflict. The Maximum Packet Size  
field is highlighted in yellow, indicating that Jumbo Frames are not enabled on the NIC used with the Genie or that  
the control application is forcing a safe packet size. Using a larger packet size improves host CPU performance,  
which can be critical when using multiple Genie devices. Note that the Maximum Packet Size field is updated only  
when an application such as CamExpert communicates with the Genie.  
24 Installing the Genie Camera  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Select NIC Advanced Configuration Properties  
From the Start menu go to Settings • Control Panel • Network Connections and select the NIC used to  
connect the Genie to.  
Open the Properties for the Ethernet GigE NIC used with the Genie.  
Click the Configure button.  
GigE NIC Configuration  
Click on the Advanced tab. Modify the values for Receive Descriptors and Jumbo Frames as follows.  
Receive Descriptors  
Select the 'Receive Descriptors' property.  
Change the value to the largest value supported by the installed NIC. In this example the value is 2048.  
GigE NIC Receive Buffers  
Genie Monochrome Series-GigE Vision Camera  
Installing the Genie Camera 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Jumbo Frames  
Select the 'Jumbo Frames' property.  
Change the value to the largest supported by the installed NIC. The Genie can then be configured to use its  
maximum Jumbo Frames size (currently 9000). In this example the NIC value is set to 9014.  
GigE NIC Jumbo Frames  
Running the Network Configuration Tool  
Once the GigE Server discovers a device, start the Network Configuration tool to verify and modify the network  
configuration of the imaging system. See "Network Configuration Tool" on page 79.  
First verify the Genie camera appears as a child of the NIC card it is connected to. By default the Genie camera is  
identified by its serial number if no user-defined name has been assigned.  
Because image transfers require considerable bandwidth through the NIC, it is recommended that a separate Gigabit  
Ethernet NIC for the Genie camera be used. Connections to the Internet or to a corporate network should be through  
a different NIC.  
26 Installing the Genie Camera  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The Network Configuration Tools allows you to:  
Configure the Windows firewall exception list  
Activate the Network Imaging driver use for image acquisition on any NIC  
Configure the NIC and camera IP settings  
Updating Genie Firmware  
The Genie firmware may need to be updated to correspond with the currently used Genie software framework. After  
installing the new Genie software package and Genie camera, update the firmware by following this procedure.  
Start the DALSA Device Manager program from the windows start menu:  
Start•Programs•DALSA•Genie•Firmware Update.  
The right hand column shows whether a firmware update is Required or Not Required.  
If an update is required, click on the Automatic button. The Update Firmware manager dialog opens and the  
new firmware version is written to the Genie camera.  
The manual button allows the user to select from multiple Genie firmware configuration files – if such files  
become available for future operational modes.  
Genie Monochrome Series-GigE Vision Camera  
Installing the Genie Camera 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The firmware update is complete when the lower message output area says "Device reset complete". Close the  
Device Manager program.  
Genie cameras manufactured in 2007 or later will display the following status LED sequence while initializing  
with the new firmware.  
Status LED will flash red then go off.  
Both LAN LEDs will flash repeatedly for a short time.  
Status LED will flash red then go off again.  
Both LAN LEDs will flash repeatedly for a short time again.  
Status LED will turn blue as normally happens during power up.  
Wait for the GigE Server to find the Genie again, then run CamExpert to test the Genie operation (as described  
below).  
Important: If the Genie power is accidentally cut off during the firmware update (such as a electrical source  
power failure or human error), the Genie is easily recovered. See "Power Failure During a Firmware Update–Now  
What?" on page 107.  
28 Installing the Genie Camera  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Test with CamExpert  
When the Genie camera is directly connected to a Gigabit network adapter on a host computer or via a network  
switch, testing the installation with CamExpert is a straightforward procedure.  
Start Sapera CamExpert by double clicking the desktop icon created during the Genie software installation.  
CamExpert will search for installed Sapera devices. In the Device list area on the left side, the connected Genie  
camera is shown or will be listed in a few seconds after CamExpert completes the automatic device search  
(device discovery).  
Select the Genie camera device by clicking on the camera user-defined name. By default the Genie camera is  
identified by its serial number. The LED of the Genie will turn green, indicating the CamExpert application is  
now connected.  
Click on the Grab button for live acquisition (the Genie default is Free Running mode). Focus and adjust the  
lens iris. See "Operational Reference" on page 31 for information on CamExpert parameters with the Genie  
camera.  
The following figure shows CamExpert with the Genie generating a diagonal test pattern.  
Genie Monochrome Series-GigE Vision Camera  
Installing the Genie Camera 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
About the User-Defined Camera Name  
The Genie can be programmed with a user-defined name to aid identifying multiple cameras connected to the  
network. For instance, on an inspection system with 4 cameras, the first camera might be labeled “top view”, the  
second “left view”, the third “right view” and the last one “bottom view”. The factory default user name is set to  
match the camera serial number for quick initial identification. Note that the factory programmed Genie serial  
number and MAC address are not user changeable.  
When using CamExpert, multiple Genie cameras on the network are seen as different "Genie_M640_x" devices.  
Click on a Genie device user name to select it for control by CamExpert.  
An imaging application uses any one of these attributes to identify a camera: its IP address, MAC address, serial  
number or User Name. Some important considerations are listed below.  
Do not use the camera's IP address as identification (unless it is a persistent IP) since it can change with each  
power cycle.  
A MAC address is unique to a single camera, therefore the control application is limited to the vision system  
with that unique camera.  
The User Name can be freely programmed to clearly represent the camera usage. This scheme is recommended  
for an application to identify cameras. In this case, the vision system can be duplicated any number of times  
with cameras identified by their function, not their serial numbers or MAC address.  
30 Installing the Genie Camera  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Operational Reference  
Camera and Sensor Information  
Camera and sensor information can be retrieved via a controlling application. Parameters such as camera model,  
firmware version, sensor characteristics, etc. are read to uniquely identify the connected Genie device.  
All these features, with the exception of the DeviceUserId, are read-only. Sapera LT or GenICam calls are used to  
retrieve this information and correctly identify the camera along with its characteristics.  
Following is an overview of CamExpert displaying this information followed by tables with the feature name  
associated to Sapera LT and to GenICam development environments.  
Access Via CamExpert  
The Camera Information Parameters tab groups parameters that contain information specific to the individual Genie  
camera.  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Read Only Parameters  
Parameter  
Description  
Device Vendor  
Device Model Name  
Device Version  
Firmware Version  
Device ID  
For the Genie Monochrome series, this is always DALSA.  
Displays the device model name (for example, Genie M640).  
Displays the device version.  
Displays the currently loaded firmware version.  
Displays the camera serial number.  
MAC Address  
Displays the unique MAC (Media Access Control) address of the Genie camera.  
User Set Parameters  
Parameter  
Description  
Device User ID  
Specifies a user written ID, of up to 15 characters, for the Genie camera.  
By default, this field is set to the serial number of the camera.  
Power-up Configuration  
Click Setting to open the Power-up configuration dialog box which allows you to specify  
camera power-up configuration. For more information, see "Power-up Configuration" on page  
32.  
Power-up Configuration  
The Power-up configuration dialog allows you to specify the camera configuration to load when powering-up the  
camera. The Genie camera flash memory contains two possible configuration settings; the Factory Default, and a  
user-defined Camera Configuration 1. The Camera Power-up configuration drop-down list box allows you to  
select either the Factory Default or a user specified camera configuration file. To save the current CamExpert  
settings to the camera user-defined (Camera Configuration) setting, click Save. To view in CamExpert a camera  
configuration file currently saved in the camera, select the configuration file in the Load configuration from  
Camera drop-down list, and click Load. See "Genie Power-up Configuration" on page 67 for a list of the saved  
parameters.  
32 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Camera Information via Sapera LT or GenICam Applications  
Genie Sapera parameters for Camera and Sensor Information:  
Interface = {GigE Vision}  
DeviceVendorName = “DALSA”  
DeviceModelName = “Genie M640” for Genie M640  
DeviceVersion = String representing the version of the camera  
Sapera  
FirmwareVersion = String representing the version of the camera firmware  
DeviceID = String representing the camera serial number  
MACAddress = String representing the camera MAC address  
DeviceUserID = String representing the user-define name for the camera  
DeviceMaxThroughput = Maximum throughput of image streaming in bytes/sec.  
DeviceScanType = {Areascan}  
ColorType = {Monochrome Sensor}  
SensorWidth = Width of the sensor in pixels  
SensorHeight = Height of the sensor in lines  
PixelSize = Number of bits per pixel  
In CamExpert, these parameters are visible under “Camera Information” and “Sensor” tabs.  
GenICam features for Camera and Sensor Information:  
DeviceVendorName = Name of camera vendor  
DeviceModelName = Name of the camera model  
DeviceVersion = Version of the device  
DeviceFirmwareVersion = Version of camera firmware  
DeviceID = Serial number of the camera  
DeviceUserID = User-defined name the camera  
DeviceScanType = {Areascan}  
DeviceMaxThroughput = Maximum number of bytes per second device supports  
DeviceRegistersStreamingStart = Announces the start of registers streaming without immediate  
checking for consistency  
DeviceRegistersStreamingEnd = Announces the end of registers streaming and perform  
validation for registers consistency before activating them  
DeviceRegistersCheck = Performs an explicit register set validation for consistency  
DeviceRegistersValid = Informs whether the current register set is valid and consistent  
SensorWidth = Width of sensor (effective pixels)  
SensorHeight = Height of sensor (effective pixels)  
WidthMax = Maximum image width. Depends on binning and decimation  
HeightMax = Maximum image height. Depends on binning and decimation  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Sensor Controls  
Genie provides a number of sensor controls to optimize image acquisitions for most imaging solutions. Following is  
an overview of the CamExpert controls displaying this information, followed by individual control function  
descriptions and tables indicating the feature name associated to Sapera LT and to GenICam development  
environments.  
Sensor Parameters: Controls Via CamExpert  
The Sensor Parameters tab groups the parameters related to the camera sensor configuration for acquisition.  
Read Only Parameters  
Parameter  
Description  
Device Scan Type  
Displays the device scan type. Possible values are area scan or linescan. This is always area  
scan for Genie.  
Color Type  
Displays the color type of the sensor. Possible values are Color Sensor or Monochrome Sensor.  
Displays the sensor width (in pixels).  
Sensor Width (in pixels)  
Sensor Height (in pixels)  
Displays the sensor height (in pixels).  
34 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User Set Parameters  
Parameter  
Description  
Frame Rate (in Hz)  
Specifies the internal trigger frame rate for free run mode, in Hz.  
Possible values range from 0.1 to 64.0 Hz for Genie M640 in full scan mode.  
(Note: the Sapera SDK specifies the frame rate in milliHertz).  
The maximum frame rate increases by using binning (see below) or partial scan (see "Partial  
Scan—Window ROI" on page 37).  
Gain (in dB)  
Specifies the sensor analog Gain factor, in dB. Possible values range from  
–6.0 to 12.0 dB, in 0.1 dB increments. For more information, see "Gain and Black Level  
Controls" on page 36.  
Black level (in 1/16 DN)  
Binning Horizontal  
Specifies the sensor black level, in 1/16 DN (digital number, which is the value assigned to a  
pixel in a digital image). Possible values range from -128 to 127.  
Enables or disables horizontal binning. Possible values are Disabled or 2 pixels. When set to 2  
pixels, the image buffer width parameter is automatically adjusted. For more information, see  
"Binning" on page 41.  
Binning Vertical  
Enables or disables the vertical binning. Possible values are Disabled or 2 lines. When set to 2  
lines, the image buffer height parameter is automatically adjusted. The maximum frame rate  
also increases.  
Test Image Selector  
Specifies the test image. Possible values are:  
Off  
Grey Horizontal Ramp  
Grey Vertical Ramp  
Grey Diagonal Ramp Moving  
Purity  
For more information, see "Internal Image Test Patterns" on page 62.  
Exposure Control  
Click Setting to open the Exposure Control dialog. For more information, see "Exposure  
Controls" on page 43.  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gain and Black Level Controls  
The Genie series of monochrome cameras provide gain and black level adjustments for the analog signal from each  
CCD pixel, before the analog to digital conversion. The software gain and black level controls can make small  
compensations to the acquisition in situations where lighting varies and the lens iris can not be easily adjusted. The  
user can evaluate Gain and Black Level by using CamExpert.  
Features and limitations are described below.  
Gain is expressed in decibels (dB). Range from -6dB to +12dB in 0.1dB increments. Gain is a multiplication  
factor to the analog signal (i.e. exposure) before digitization.  
Note that a gain of 6dB is a multiplier of 2 (doubles the level).  
Increasing gain increases the amplitude of the analog video signal but also increases the sensor analog noise  
proportionately, before analog to digital conversion.  
Note: Doubling gain does not necessarily double the digital data due to the Black Level Offset value as  
described below.  
Black level offset is applied to the sensor analog signal to shift the DC level of the video signal. Black level is  
an additive offset to the analog video signal before digitization.  
Black level offset increases the brightness of the video signal equally. Therefore any area of the video that is  
black will brighten to some gray level as offset is increased.  
Black level offset is expressed as a number ranging from -128 to 127. The offset is achieved as a change in the  
analog signal from the sensor where a control number change of 1 is 1/16th of a DN (digital number) pixel  
change. In other words, a control change of 16 is required for each change in pixel value, therefore a maximum  
control value of 127 will cause a black pixel (00) to have a gray value of about 8.  
The resultant output Gain/Offset formula is  
OutputData =  
where : Gain = 20log(multiplier)  
(
Exposure*Gain + Offset  
)
Gain and Offset Control via Sapera LT or GenICam Applications  
Genie Sapera parameters for Gain and Black level:  
Gain = Amplification in dB from -6.0 to 12.0 dB  
BlackLevel = DC offset in 1/16th of DN, range from -128 to 127  
Sapera  
In CamExpert, these parameters are available under the “Sensor” tab.  
GenICam features for Gain and Black level:  
GainRaw = Analog gain in tenth of dB (0.1 dB)  
BlackLevelRaw = Black level (offset) in 1/16 of DN  
36 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Partial Scan—Window ROI  
Partial Scan (vertical cropping)  
The Partial Scan mode, also know as vertical cropping, reduces the number of video lines grabbed for a frame. By  
not scanning the full vertical area of the sensor, the maximum possible acquisition frame rate is proportionately  
increased (as an extreme example, the M640 scanning a one line frame, exposed around 589fps).  
Scan Start Offset  
Partial Image Scan  
Scan Line Count  
Partial Scan Illustration  
Maximum Frame Rate Examples  
Vertical Lines  
Acquired  
M640  
Maximum  
Frame Rate  
M1024  
Maximum  
Frame Rate  
M1400  
Maximum  
Frame Rate  
1024  
768  
512  
480  
240  
120  
60  
--  
--  
15 fps  
20 fps  
27 fps  
28 fps  
42 fps  
55 fps  
66 fps  
73 fps  
81 fps  
--  
20 fps  
28 fps  
30 fps  
50 fps  
74 fps  
99 fps  
118 fps  
146 fps  
--  
64 fps  
115 fps  
194 fps  
293 fps  
394 fps  
589 fps  
30  
1
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Partial Scan (horizontal cropping)  
Genie also can crop the acquisition horizontally by grabbing less pixels on each horizontal line. Additionally a  
horizontal offset value will start the grab from any pixel count, as shown in the following figure. Note that  
horizontal cropping does not increase the maximum frame rate due to the CCD readout architecture.  
Horizontal Crop  
Horizontal Scan offset  
Active Horizontal Scan  
Window ROI  
Vertical and Horizontal Cropping can be combined to grab only a region of interest (ROI). Besides eliminating post  
acquisition image cropping done by software in the host computer, a windowed ROI grab reduces the bandwidth  
required on the Gigabit Ethernet link since less pixels are transmitted. See "CamExpert Image Buffer and ROI  
Parameters" on page 40 to use CamExpert to configure image cropping.  
38 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Window ROI Control via Sapera LT or GenICam Applications  
Genie Sapera parameters for Partial Scan and Window ROI:  
Width = Buffer width in pixels  
Height = Buffer height in lines  
OffsetX = Horizontal Offset in pixels of the leftmost pixel relative to the sensor  
OffsetY = Vertical offset in lines of the uppermost pixel relative to the sensor  
PixelFormat = {Monochrome 8-bit, Monochrome 10-bit}  
Sapera  
GenICam features for Partial Scan and Window ROI:  
Width = Width of image/area of interest  
Height = Height of image/area of interest  
OffsetX = Left coordinate of area of interest  
OffsetY = Top coordinate of area of interest  
LinePitch = Distance between consecutive lines in bytes  
PixelColorFilter = Color filter convention of the image  
PixelFormat = Format of the image pixels as per GigE Vision specification  
PixelDynamicRangeMin = Minimum pixel value sent by camera  
PixelDynamicRangeMax = Maximum pixel value sent by camera  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CamExpert Image Buffer and ROI Parameters  
CamExpert provides controls to configure acquisitions via the Image Buffer and ROI Parameters tab. The image  
buffer can be easily cropped as desired. Below is the CamExpert dialog and parameter descriptions follow.  
Parameter  
Description  
Pixel Format  
For the Genie Monochrome series, the image buffer format is Monochrome 8-bit or 10-bit.  
Displays the image buffer width (X axis), in pixels.  
Width (in Pixels)  
Height (in Pixels)  
OffsetX (in Pixels)  
Displays the image buffer height (Y axis), in pixels.  
Specifies the offset in X, from the left of the image, when using an ROI. The image buffer  
width is automatically adjusted to compensate for this offset.  
OffsetY (in Lines)  
Image Flip  
Specifies the offset in Y, from the top of the image, when using an ROI. The image buffer  
height is automatically adjusted to compensate for this offset.  
Enables hardware based horizontal image flip.  
Note: When operating in binning mode, the resolution is halved and the coordinate system is scaled accordingly.  
For instance, an OffsetX of 20 pixels at nominal resolution is equivalent to an OffsetX of 10 pixels with  
horizontal binning enabled.  
40 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Binning  
Binning is the process where the charge on two (or more) adjacent pixels is combined. This results in increased light  
sensitivity since there is twice the sensor area to capture photons. The sensor spatial resolution is reduced but the  
improved low-light sensitivity plus lower signal-noise ratio may solve a difficult imaging situation. The user can  
evaluate binning by using CamExpert.  
Genie supports horizontal and vertical binning independently, by a factor of 2 in each axis. Specifically if horizontal  
binning only is activated, a nominal 640x480 image is reduced to 320x480. If vertical binning only is activated, the  
image is reduced to 640x240. With both binning modes activated, the resulting image is 320x240.  
Vertical binning also provides an increase in maximum acquisition frame rate. The frame rate increase depends on  
the camera model and amount of vertical cropping used. The following graphic illustrates binning.  
1
2
3
4
639 640  
320  
Repeated for each  
line of pixels  
1
2
Horizontal Binning  
Line  
1
Line  
1
Line  
2
Repeated for each column of pixels  
Line  
3
Line  
2
Line  
4
Line  
479  
Line  
240  
Vertical Binning  
Line  
480  
Horizontal and Vertical Binning Illustration  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Binning Control via Sapera LT or GenICam Applications  
Genie Sapera parameters for Binning:  
BinningHorizontal = {Disabled = 1, 2 pixels = 2}  
BinningVertical = {Disabled = 1, 2 lines = 2}  
Sapera  
In CamExpert, these parameters are available under the “Sensor” tab.  
GenICam features for Binning:  
BinningHorizontal = Number of horizontally binned cells (1 = no binning)  
BinningVertical = Number of vertically binned cells (1 = no binning)  
Trigger Modes  
Genie image exposures are initiated by an event. The trigger event is either the camera's programmable internal  
clock used in free running mode, an external input used for synchronizing exposures to external triggers, or a  
programmed function call message by the controlling computer. These triggering modes are described below.  
Free running (trigger disabled): The Genie free-running mode has a programmable internal timer for frame  
rate and a programmable exposure period. Frame rate is 0.1 fps to the maximum supported by the sensor.  
Exposures range from 100 µs to a maximum also dependent on the current frame rate. This always uses  
Synchronous mode where exposure is aligned to the sensor horizontal line timing.  
External trigger: Exposures are controlled by an external trigger signal. External signals are isolated by an  
opto-coupler input with a time programmable debounce circuit. See "General Inputs" on page 49. The  
following section provides information on external trigger timing.  
Software trigger: An exposure trigger is sent as a control command via the Ethernet network connection.  
Software triggers can not be considered time accurate due to network latency and sequential command jitter.  
But a software trigger is more responsive than calling a single-frame acquisition (Snap command) since the  
latter must validate the acquisition parameters and modify on-board buffer allocation if the buffer size has  
changed since the last acquisition.  
42 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Exposure Controls  
Exposure Control modes define the method and timing of how to control the sensor integration period. The  
integration period is the amount of time the sensor is exposed to incoming light before the video frame data is  
transmitted to the controlling computer.  
Exposure control is defined as the start of exposure and exposure duration.  
The start of exposure can be an internal timer signal (free-running mode), an external trigger signal, or a  
software function call trigger.  
The exposure duration can be programmable (such as the case of an internal timer) or controlled by the external  
trigger pulse width.  
For the Genie camera, exposure control modes are "Free-running Programmable Exposure" on page 43 (timer),  
Exposure" on page 45 (trigger pulse width). Following are details for each mode.  
Free-running Programmable Exposure  
Genie is in a multifunctional free running mode with the following features:  
Internal trigger programmable from maximum sensor frame rate down to 0.1Hz.  
Exposure duration is user programmable (exposure maximum is dependent on the frame rate). Minimum  
exposure is 100µs.  
Supports vertical and horizontal binning.  
Exposure synchronization timing is "Synchronous Mode" on page 46 where the exposure is aligned with the  
sensor horizontal line timing and the next acquisition is triggered by an internal programmable timer.  
Image readout is simultaneous where the grabbed image frame is readout during the next frame exposure time.  
This allows for fastest possible frame rates. See the timing diagram below.  
Free-running Programmable Exposure Timing  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
External Trigger Programmable Exposure  
Also known as “Edge Pre-select” exposure. See the timing diagram below.  
The external trigger edge initiates the exposure process. The active external trigger edge can be selected as  
either the low-high or high-low transition.  
The delay from active trigger edge to start of exposure is programmable from 1μs to 4 seconds (1μs steps) .  
Exposure duration is programmable from 100μs to 4 seconds (1μs steps).  
Supports "Synchronous Mode" on page 46 timing for fastest possible frame rates. Start of exposure is aligned  
on the next horizontal line while exposure duration granularity is 1µs. Exposure and sensor readout can be  
concurrent.  
Supports "Reset Mode" on page 47 timing. Exposure granularity is 1µs. Exposure and sensor readout must be  
sequential, limiting the maximal frame rate.  
Any external trigger received before the previous exposure is complete is ignored. An application can elect to  
receive messages about ignored triggers. See "Events" on page 63.  
Programmable Synchronous Mode Exposure Timing  
Programmable Reset Mode Exposure Timing  
44 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
External Trigger Level-controlled Exposure  
Also known as “Pulse Width Control” exposure. See the timing diagram below.  
The external trigger edge initiates the exposure process. The active external trigger edge can be selected as  
either the low-high or high-low transition.  
No delay from active trigger edge to start of exposure.  
Exposure is stopped by the opposite edge on the trigger signal. Therefore the exposure time is defined by the  
trigger pulse duration.  
Supports "Reset Mode" on page 47 trigger timing only.  
External Trigger Level-controlled Exposure Timing  
Exposure Controls via Sapera LT or GenICam Applications  
Genie Sapera parameters for Exposure Control:  
FrameRate = 0.1 Hz up to max. frame rate supported by sensor in current mode of operation.  
Only available with Trigger disabled.  
ExposureMode = {Programmable = 1, Pulse Controlled = 2}  
ExposureTime = Exposure duration in µs  
Sapera  
In CamExpert, these parameters are available under “Sensor” tab.  
GenICam features for Exposure Control:  
ExposureMode = {Off = 0, Timed = 1, TriggerWidth = 2, TriggerControlled = 3,  
ResetContinuous = 4}  
ExposureTimeRaw = Exposure duration in µs  
AcquisitionFrameRate = Controls the desired frame rate of the camera in mHz (0.001 Hz). Only  
available when trigger is disabled.  
AcquisitionFrameCount = Number of frames to be acquired in MultiFrame acquisition mode  
AcquisitionMode = {Continuous = 0, SingleFrame = 1, MultiFrame = 2}  
AcquisitionStart = Start image capture using currently selected acquistion mode  
AcquisitionStop = Stop image capture  
AcquisitionAbort = Abort image capture  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Synchronization Timing  
Genie supports two types of sensor synchronization used to align the exposure to sensor timing:  
Synchronous Mode: Exposure is synchronous to the line timing of the sensor. Exposure granularity is 1µs and  
the readout can be concurrent to the exposure for the fastest possible frame rate.  
Reset Mode: Timing is reset to initiate exposure of next frame. Exposure granularity is 1µs, but readout must  
be sequential to exposure, reducing the maximum achievable frame rate.  
Synchronous Mode  
Synchronous mode starts the exposure period aligned to the sensor horizontal line timing and the programmable  
duration granularity is 1µs.  
In the case of the Genie M640, a horizontal line occurs every 31.77µs.  
Exposure duration is from a minimum of 100µs up to 4 sec.  
In this mode, sensor exposure and sensor readout of the previous frame's exposure occur simultaneously. This  
allows operating the sensor up to its maximum frame rate.  
Any trigger received before the end of the exposure is ignored. The application can elect to receive messages  
about ignored triggers. See "Events" on page 63.  
Since the external trigger is asynchronous with the Genie horizontal line timing, the frame exposure start is  
subject to 1 horizontal line jitter.  
Synchronous Mode Timing example for Genie M640  
46 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Reset Mode  
Exposure starts immediately after a valid trigger. There is no jitter on the start of exposure.  
Exposure time is programmable or controlled by the trigger pulse width.  
Minimum exposure is 100 µs – maximum is 4 seconds, with control steps of 1µs.  
Sensor readout must complete before the next exposure can start. That is, exposure and readout are sequential.  
Therefore, the maximum frame rate is lower than for Synchronous mode.  
Any external trigger received before the previous exposure/read out sequence is complete is ignored. An  
application can elect to receive messages about ignored triggers. See "Events" on page 63.  
Reset Mode Timing example for Genie M640  
Synchronization Mode via Sapera LT or GenICam Applications  
Genie Sapera parameters for Synchronization Mode:  
ExposureAlignment = {Synchronous = 0, Reset = 1}  
In CamExpert, these parameters are available under the “Sensor” tab in the “Exposure Control”  
dialog box.  
Sapera  
GenICam features for Synchronization Mode:  
SensorSynchronization = {Synchronous = 0, Reset = 1}  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CamExpert I/O Controls Dialog  
CamExpert groups the Genie I/O Controls Parameters in one group. These parameters allow configuring the Genie  
inputs and outputs for type of signal and signal polarity. The screen capture below shows the CamExpert I/O  
parameters dialog and is followed by a descriptive overview. Detailed information on inputs and outputs follow this  
section.  
I/O Controls Dialog  
Parameter  
Description  
Trigger  
Enables or disables the Genie camera trigger.  
Trigger Source  
Specifies the trigger source. Possible values are Software, Input 1, or Input 2.  
Note that this field is only available when the Trigger parameter is True.  
Frames per Trigger  
Input Settings  
Set the number of frames acquired per trigger – max. 64k  
(driver 1.10 limited to 1 frame).  
Click on Setting to open the Input Settings dialog box, which allows you to specify the trigger  
input settings. For more information, see "General Inputs: Settings Via CamExpert" on page 49.  
Output Settings  
Click on Setting to open the Output Settings dialog box, which allows you to specify the  
trigger output settings. For more information, see "General Outputs: Settings via CamExpert"  
on page 51.  
For more information on triggers, see "General Inputs" on page 49.  
48 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
General Inputs  
External Input Signal Opto-coupler & Debounce Circuit  
Genie provides two sets of opto-coupled inputs for either RS422 or TTL signals. These can be used as external  
trigger sources.  
See "12-Pin Hirose Connector Signal Details" on page 90 for connector pinout and electrical information. The  
cable shell and shield should electrically connect the Genie chassis to computer chassis for maximum EMI  
protection.  
For external triggers, a rising edge signal is suggested to minimize the time it takes for the opto-coupler to  
change state. (The opto-coupler response time is typically 10µs for rising edge compared to 50μs for falling  
edge).  
Each input incorporates a signal debounce circuit (following the opto-couple) to eliminate short noise  
transitions that could be wrongly interpreted as a valid pulse. The duration is user-programmable from 1µs to  
255µs with CamExpert.  
Note, the external trigger input propagation delay is dependent on the signal used to activate the opto-coupled  
input. Typical delays are 3 µs for Active Open and 5 µs for Active Close.  
General Inputs: Settings Via CamExpert  
CamExpert provides control of inputs via the I/O Controls Parameters tab. The Input Settings dialog box allows  
you to view the signal and status for each pin on the Hirose connector. The Polarity drop-down list boxes, located  
in the INPUT Settings area, allow you to specify the polarity of the Input 1 and Input 2 as either Active High or  
Active Low. The Minimum duration field for each input, allows you to specify the minimum trigger length (1-  
255µs ) so that input transitions are debounced to prevent unwanted trigger events.  
Input Settings Dialog  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Input Controls via Sapera LT or GenICam Applications  
Genie Sapera parameters for Trigger Modes and General Inputs:  
TriggerDelayToIntegration = Delay in µs from trigger to exposure  
TriggerEnable = {FALSE, TRUE}  
TriggerSource = {Input 1 = 0, Input 2 = 1, Software = 2}  
Sapera  
TriggerSoftware = {FALSE, TRUE}  
FramesPerTrigger = Frame count 1 to 64k  
PolarityInput_x = {Active High = 0, Active Low = 1}  
DebounceInput_x = debouncing period in µs (from 1 to 255 µs)  
GenICam features for Trigger Modes and General Inputs:  
TriggerMode = {Off = 0, On = 1}  
TriggerSelector = (not used)  
TriggerSoftware = Generates a software trigger to start the acquisition in software trigger mode  
TriggerSource = {Line2 = 1, Software = 2}  
TriggerActivation = {LevelLow = 0, LevelHigh = 1}  
TriggerDelayAbs = Absolute delay to apply in us after reception of the trigger signal before  
starting exposure  
InputLineSelector = Index to general input {input1=0, input2=1}  
InputLinePolarity = {Active High = 0, Active Low = 1}  
InputLineDebouncingPeriod = debounce period in µs (from 1 to 255 µs)  
InputLineValue = Read input line state {low=0, high=1}  
50 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Strobe and General Outputs  
Genie provides two sets of opto-coupled outputs (see "External Outputs" on page 92). These can be used as a strobe  
signal to control lighting or to generate programmable pulses when specific events are generated by the camera.  
They can also be set to a static state (close or open) by the application.  
See "12-Pin Hirose Connector Signal Details" on page 90 for connector pinout and electrical information.  
General Outputs: Settings via CamExpert  
The Output Settings dialog box allows you to configure the event mode for both output 1 and output 2. Each  
output can be set independently to one of the available event modes. A typical usage of output is to control a strobe  
light in relation to the camera exposure. Select the output to configure by clicking on the Output 1 or Output 2  
buttons located at the top of the dialog box. Use the Event mode drop-down list box to select the required event  
mode.  
The following event modes are available:  
Open (default)  
Close  
Strobe On: Start of Exposure (used for strobe pulse)  
Pulse On: Valid Trigger  
Pulse On: Invalid Trigger  
Pulse On: Start of Readout  
Pulse On: End of Readout  
Pulse On: End of Acquisition  
Pulse On: Input 1  
Pulse On: Input 2  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
When an event mode is selected, its trigger output schematic or signal timing diagram is displayed, as well as any  
other additional parameters for the mode.  
For most event modes, the trigger output signal can be set to either Active Open (that is high with the load  
connected to a voltage source) or Active Closed (where current is drawn through the load). The output delay can be  
set from 0 to 4 seconds, in increments of 1 µs. The pulse duration can be set from 100µs to 4 seconds, in increments  
of 1 µs.  
Open and Close Output Settings  
You can open and close the output circuit using software rather than hardware events, to control external devices.  
To control the output setting with Sapera LT see "Output Control via Sapera LT or GenICam Applications" on page  
56.  
Strobe On Start of Exposure Event Mode  
The Strobe On Start of Exposure event mode is used when controlling a strobe light using the Genie output pin. The  
exposure delay parameter is specified using the Sensor Parameters tab Exposure Control setting.  
For Synchronous mode, the exposure start timing is aligned to the line period of the sensor. This can delay the start  
of exposure by an amount of up to 31.77µs for the Genie M640. For more information on exposure synchronous  
time see "Exposure Controls" on page 43.  
52 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Pulse On Valid Trigger Event Mode  
The Pulse On Valid Trigger event mode generates an output signal when a valid input trigger is received.  
Pulse On Invalid Trigger Event Mode  
This event mode generates an output signal when an invalid input trigger is received. An invalid trigger is any  
trigger received while the camera is engaged in frame acquisition (exposure and readout) and cannot accept trigger  
inputs. This is shown by the trigger exclusion region in the following diagram.  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Pulse On Start of Readout Event Mode  
The Pulse On Start of Readout event mode generates an output signal when the camera begins a readout operation  
from the sensor.  
Pulse On End of Readout Event Mode  
The Pulse On End of Readout event mode generates an output signal when the camera finishes a readout operation  
from the sensor.  
54 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Pulse On End of Acquisition Event Mode  
The Pulse On End of Acquisition event mode generates an output signal when the acquisition process is terminated  
using software.  
Pulse On Input 1 or Input 2 Event Modes  
The Pulse On Input 1 or Input 2 event modes generate an output signal when the specified input signal is asserted.  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Output Control via Sapera LT or GenICam Applications  
Genie Sapera parameters for Strobe and General Outputs.  
OutputSelectorOutput_x = {Open = 0, Close = 1, Strobe On: Start of Exposure = 2, Pulse On:  
Sapera  
Valid Trigger = 4, Pulse On: Invalid Trigger = 5, Pulse On: Start of Readout = 6, Pulse On: End  
of Readout = 7, Pulse On: End of Acquisition = 8, Pulse On: Input 1 = 9, Pulse On: Input 2 = 10}  
PulseDelayOutput_x = Delay in µs to assert pulse output  
PulseDurationOutput_x = Pulse duration in µs  
PolarityOutput_x = {Active Close = 0, Active Open = 1}  
GenICam features for Strobe and General Outputs:  
OutputLineSelector = Index to select output line {output 1 = 0, output 2 = 1}  
OutputLineMode = {SoftwareDriven = 0, EventDriven = 1}  
OutputLineEventSource = Event generating output line pulse {StartOfTrigger=0,  
StartOfExposure=1, EndOfExposure=2, StartOfReadout=3, EndOfReadout=4,  
EndOfAcquisition=5, EventOnInputLine1=6, EventOnInputLine2=7, OverTrigger=8,  
OutputLinePulsePolarity = State of output opto-coupler {Active Close = 0, Active Open = 1}  
OutputLinePulseDelay = Delay in µs to assert pulse output (range 0 to 64k)  
OutputLinePulseDuration = Pulse duration in µs (range 0 to 64k)  
OutputLineValue = static output state {Open = 0, Close = 1}  
Genie Processing Features  
The Genie monochrome series of cameras support a number of functions to enhance acquisitions or perform real  
time processing. Functions can be combined to solve specific imaging situations. The user can enable and evaluate  
each operation by using CamExpert.  
Lookup Table (LUT)  
The Genie camera includes a user programmable LUT as a component of its embedded processing features. The  
LUT is used for operations such as gamma adjustments, invert and threshold processes. CamExpert has a number of  
built in LUT operations for the user to explore (see "CamExpert LUT Controls" on page 87).  
For monochrome sensors, the LUT table is a single 8-bit or 10-bit LUT (8/10-bit in, 8/10-bit out) as illustrated in  
the following figure. Pixel data when read out of the sensor is passed through the LUT memory array, where the  
new programmed pixel value is then passed to the Genie output circuit. The LUT data table is stored along with  
other parameters with the user configuration function (see "Power-up Configuration" on page 32).  
56 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Simplified Genie LUT Block Diagram  
(8-bit example)  
0
1
2
3
255  
254  
253  
252  
Pixel  
Data  
Sensor &  
A/D  
Circuit  
Output  
Circuit  
252  
253  
254  
255  
3
2
1
0
Programmed as  
Invert Function  
Simplified 8-bit LUT Block Diagram  
LUT Control via Sapera LT or GenICam Applications  
Genie Sapera parameters for LUT:  
LUTEnable = {FALSE, TRUE}  
LUTFormat = {Mono 8, Mono 10 – Unsigned}  
LUTNumberEntries = Number of entries in the LUT  
(256 for an 8-bit LUT, 1024 for a 10-bit LUT)  
Sapera  
LUTData = Array of data representing the LUT content  
Sapera++ classes used:  
SapLut Class implements LUT management.  
SapAcquisition::GetLut to get a valid SapLut object.  
SapAcquisition::ApplyLut to program the SapLut object.  
In CamExpert, these features are available from the “Pre-Processing” menu.  
GenICam features for LUT:  
Not supported  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Flat Field (Image Shading) Correction  
Image Shading correction, also know as Flat Field Correction is the process of eliminating small gain differences  
between pixels in a sensor array. That sensor when exposed to a uniformly lit field will have no gray level  
differences between pixels when calibrated flat field correction is applied to the image. The Genie camera stores flat  
field correction data until power off or in its user setting state for recall at any time (see "Power-up Configuration"  
on page 32). Flat field correction data is composed of 8 bit gain and 8 bit offset coefficients.  
The CamExpert Flat Field Correction tool allows calibrating. saving, and loading the flat field calibration data for  
any Genie camera being controlled.  
Before performing calibration, verify Genie acquisition with a live grab. Also at this time make preparations to grab  
a flat light gray level image, required for the calibration, such as a clean evenly lighted white wall or non-glossy  
paper. Note the lens iris position for a white but not saturated image. Additionally check that the lens iris closes well  
or have a lens cover to grab the dark calibration image.  
Flat Field Correction Calibration Procedure  
Calibration is the process of taking two reference images, one of a black field – one of a light gray field (not  
saturated), to generate correction data for images captured by Genie. Each sensor pixel data is modified by the  
correction factor generated by the calibration process, so that each pixel now has an identical response to the same  
illumination.  
Start the Flat Field calibration tool via the CamExpert menu bar:  
Pre-processing • Flat Field Correction • Calibration.  
Flat Field Calibration Window  
The Flat Field calibration window provides a three step process to acquire two reference images and then save the  
flat field correction data for the Genie used. To aid in determining if the reference images are valid, a histogram tool  
is provided so that the user can review the images used for the correction data.  
58 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CamExpert Flat Field Calibration Menu  
Click on the Advanced Setting button to change the default number of frames averaged for each calibration  
step. The default value is 10 frames.  
Setup the camera to capture a uniform black image. Black paper with no illumination and the camera lens’ iris  
closed to minimum can provide such a black image.  
Click on Acquire Black Image. The flat field calibration tool will grab video frames, analyze the pixel gray  
level spread, and present the statistics. The desired black reference image should have pixel values less then 20.  
If the results are acceptable, accept the image as the black reference.  
Setup the camera to acquire a uniform white image (but not saturated white). Even illumination on white paper  
can be used, with a gray level of 128 minimum. It is preferable to prepare for the white level calibration step  
before starting the calibration procedure.  
Click on Acquire White Image. The flat field demo will grab video frames, analyze the pixel gray level  
spread, and present the statistics. The captured gray level for all pixels should be greater than 128. If acceptable  
accept the image as the white reference.  
Click on Save. The flat field correction data is saved as a TIF image with a file name of your choice  
(suggestions are the camera name and its serial number).  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using Flat Field Correction  
From the CamExpert menu bar enable Flat Field correction (Pre-Processing • Flat Field Correction • Hardware).  
Now when doing a live grab or snap, the incoming image is corrected by the current flat field calibration data for  
each pixel.  
Use the menu function Tools • Flat Field Correction • Load to load in a flat field correction image from  
previously saved calibration data. CamExpert allows saving and loading calibration data for all cameras used with  
the imaging system.  
Flat Field Correction Control via Sapera LT or GenICam Applications  
Genie Sapera parameters for Flat Field Correction:  
FlatFieldEnable = Enable Flat Field Correction {False=0, True=1}  
FlatFieldFormat = {RO: mono 8, mono 9, mono 10, RGB}  
FlatFieldWidth = read buffer width  
FlatFieldHeight = read buffer height  
FlatFieldGainMin = read minimum gain value  
Sapera  
FlatFieldGainMax = read maximum gain value  
FlatFieldOffsetMin = read minimum offset value  
FlatFieldOffsetMax = read maximum offset value  
FlatFieldGainBuffer = Flat Field correction gain data buffer  
FlatFieldOffsetBuffer = Flat Field correction offset data buffer  
Sapera++ Class constructor: SapFlatField::SapFlatField  
In CamExpert, these features are available from the “Pre-Processing” menu.  
GenICam features for Flat Field Correction:  
Not supported  
60 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Image Flip  
Horizontal  
The Genie supports a software controlled horizontal flip function as shown in the following figure. The process is  
done in hardware with no loss of acquisition frame rate.  
Horizontal Flip  
Vertical  
As shown in the following figure, a vertical flip function is simply accomplished by mounting the Genie camera  
upside down and by programming the camera to do a horizontal flip. Genie provides identical mounting holes on  
both its top and bottom side to ease installations.  
Mount Genie  
Horizontal Flip  
Upside Down  
Image Flip Illustrations  
Genie Sapera parameter for Image Flip:  
ImageFlip = {disabled=0, horizontal=1}  
In CamExpert, this feature is available in the Image Buffer menu.  
Sapera  
Not supported  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Internal Image Test Patterns  
The Genie camera includes a built in test pattern generator that can be used to confirm camera Ethernet connections  
or driver installations, without the need for a camera lens or proper lighting. The pattern generator inserts video just  
after the sensor A/D converter, therefore Genie processing such as the LUT act on the generator images or on sensor  
images.  
CamExpert is used to easily enable and select the Genie test patterns. As shown in the following figure, select the  
Sensor tab, then select one of the four patterns from the drop menu. Select live grab to see the pattern output.  
Genie Test Pattern Selection – on Sensor Tab  
The Genie test patterns are:  
Horizontal ramp: successive pixel's gray level is incremented by 1 to maximum pixel value then repeated until  
the end of line. The gray level is reset to 0 on the following line.  
Vertical ramp: similar to the horizontal ramp, successive lines are incremented by 1 gray level then repeated  
for the full frame.  
Moving diagonal ramp: combination of the 2 previous schemes, but first pixel in image is incremented by 1  
between successive frames. This is a good pattern to indicate motion when doing a continuous grab.  
Purity: a purity pattern where all pixels have the same value. The gray value is incremented by one on  
successive frames to maximum then repeated. This also provides motion for live grabs.  
62 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Test Image Select via Sapera LT or GenICam Applications  
Genie Sapera parameters for Image Test Patterns:  
TestImageSelector = {Off = 0, Grey Horizontal Ramp = 1, Grey Vertical Ramp = 2,  
Grey Diagonal Ramp Moving = 3, Purity = 4}  
Sapera  
In CamExpert, these parameters are available in the “Sensor” tab.  
GenICam features for Image Test Patterns:  
TestImageSelector = {Off = 0, HorizontalWedge = 1, VerticalWedge = 2,  
DiagonalMovingWedge = 3}  
Events  
Genie supports a number of events that a control application can monitor. Events provide real time notification on  
various stages of the acquisition sequence and of error conditions. A Sapera application registers callbacks for those  
events that need monitoring.  
Sapera Callbacks  
Two types a callbacks can be registered for events when using the Genie:  
Transfer events concerning host system buffers.  
Use the Sapera Transfer Module  
In the Sapera C library: see CorXferRegisterCallback  
In the Sapera++ library: see SapXferCallbackInfo class  
Acquisition events concerning the acquisition device, specifically the Genie camera.  
Use the Sapera Acquisition Module  
In the Sapera C library: see CorAcqRegisterCallback  
In the Sapera++ library: see SapAcqDeviceCallbackInfo class  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Acquisition Device Event Name  
(case sensitive strings)  
Description  
Start of Trigger  
Start of Exposure  
End of Exposure  
Feature Value Changed  
Feature Info Changed  
Invalid Trigger  
Trigger is valid based on the programmed trigger parameters  
Exposure has started  
Exposure is complete  
Parameter value is changed  
Configuration parameter is changed  
Trigger event (software or external) was invalid  
External Input # 1 has received a valid signal  
External Input # 2 has received a valid signal  
External Output # 1 has changed state  
External Output # 2 has changed state  
Input Event 0  
Input Event 1  
Output Event 0  
Output Event 1  
Transfer Event Name  
Description  
End of frame transfer  
Video frame transferred to host buffer  
Event Selection via GenICam Applications  
GenICam features for Events:  
EventSelector = {AcquisitionTrigger = 2, ExposureStart = 3, ExposureEnd = 4}  
EventNotification = {Off = 0, GigEVisionEvent = 1}  
64 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Network Controls & GigE Vision Parameters  
This section describes how to optimize the network configuration for maximum Genie bandwidth. Optimization of  
these parameters is highly dependent on the number of cameras connected to a NIC, the data rate of each camera  
and the trigger modes used.  
Important: Laptop computers may have issues even with a GigE NIC port, either built in or as a PCMCIA  
device. This section describes optimizations for both desktop and laptop computers, but laptops may require  
additional customization as described in section "Laptop Computer Networking Issues" on page 111.  
CamExpert GigE Vision Parameters  
The Automatic Network Configuration mode sets parameters to a default state. The Optimize mode sets the packet  
size to the maximum value as reported by the NIC driver. If this does not provide satisfactory performance, it is  
possible to optimize transfers by manually setting the network configuration parameters. The following screen shot  
of the GigE Vision Parameters shows the CamExpert control set to Manual. Descriptions for each parameter  
follow.  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parameter  
Description  
Network Configuration Mode  
Specifies the Network Configuration Mode as either Automatic, Manual, or Optimize. In  
general use Optimize mode. Some computers, especially laptops, may require manual  
optimization of network parameters.  
The following parameters can be modified when Manual mode is selected.  
Inter-Packet Delay (in sec)  
Packet Size (in bytes)  
Specifies the inter-packet delay, in sec. The range of permitted values is 0.000000 to  
0.065535. The inter-packet delay is the minimum time interval between two successive  
packets. This can be increased if the NIC is unable to keep up with packet arrivals (thus  
dropping packets–seen as video noise).  
Specifies the maximum packet size, in bytes. The range of possible values is 576 to 1500,  
in increments of 4 bytes when the NIC does not support jumbo packet. The maximum is  
currently 9000 bytes when jumbo packets are supported (see "Increasing Adapter Buffers  
and Jumbo Frames" on page 24 to enable jumbo packets on the NIC). In most situations,  
use the largest possible packet size supported by your network elements. In order to  
support jumbo packets, all intermediate network elements must support them, otherwise  
they will simply be silently discarded and no image data will reach the PC.  
Heartbeat Timeout (in Sec)  
Maximum Packet Resend  
Specifies the heartbeat timeout, in seconds. The range of permitted values is 0.5 to 65, in  
increments of 0.001 seconds. This is used by the camera to ensure the PC application is  
still linked. If the heartbeat timeout expires, the camera will shutdown the connection to  
the current application.  
Sets the percentage of packets that can be resent for each frame. This is used to ensure  
the streaming data (including resends) does not exceed the Ethernet link capacity. As an  
example, a system capturing at 80 MB/s can allow 25% of packet resends without  
exceeding 100 MB/s (about the maximum capacity of a gigabit Ethernet link).  
Network Controls via Sapera LT or GenICam Applications  
Genie Sapera parameters for Network Configuration:  
NetworkConfigurationMode = {Automatic = 0, Manual = 1}  
InterPacketDelay = Minimum delay in µs between image packets  
PacketSize = Image packet size in bytes  
HeartbeatTimeout = Heartbeat period (watchdog) in ms before camera disconnect  
MaximumPacketResend = Sets percentage of packets that can be resent per frame  
Sapera  
In CamExpert, these parameters are available under the “GigE Vision” tab.  
GenICam features for Network Configuration:  
PayloadSize = Size of the payload in bytes. This is the total number of bytes sent in the payload.  
No packet headers.  
Other networks parameters may be available through the 3rd party package used.  
66 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie Power-up Configuration  
On power up the Genie camera initializes to a factory default state which sets the camera with neutral parameters  
and in free run mode. The default state ensures that the camera is ready for acquisition. Genie also provides storage  
for one user-defined state. This user state allows quick camera configuration for a known repeatable imaging  
system. The following table describes the camera parameters stored in the user state. See "Power-up Configuration"  
on page 32 for information on saving the user state with CamExpert.  
Parameter  
Description  
ROI  
Region of interest used to crop the image  
Pixel Format  
Frame Rate  
Exposure mode  
Exposure duration  
Exposure synchronization  
Gain  
Defines the pixel format (MONO8)  
Defines the frame rate for free run mode.  
Defines the exposure mode (Programmable or Pulse Controlled)  
Defines the exposure duration for Programmable mode  
Synchronous or Reset synchronization mode  
Defines the sensor analog Gain factor.  
Black Level  
Binning  
Defines the sensor analog Black level factor.  
Horizontal and vertical binning factor  
Flip  
Horizontal flip: Off or On  
Image source  
Trigger enable  
Trigger source  
Trigger delay  
GPI settings  
GPO settings  
LUT  
Defines the image source as the sensor or one of the stored image patterns.  
Free-running or triggered  
Selects the trigger input (input pin or software)  
Defines the delay from input trigger to exposure start.  
Defines the operational mode of the general input pins.  
Defines the operational mode of the general output pins  
Lookup Table function On or Off plus the LUT data.  
FFC function On or Off plus the offset/gain data.  
Flat Field Correction  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power-up Control via Sapera LT or GenICam Applications  
Genie Sapera parameters for Power-up Configuration:  
Power-upConfig = {Factory Default = 0, Camera Configuration 1 = 1}  
SaveCameraConfigurationSelector = {Camera Configuration 1 = 1}  
SaveCameraConfiguration = Write to save selected camera configuration  
LoadCameraConfigurationSelector = {Factory Default = 0, Camera Configuration 1 = 1}  
LoadCameraConfiguration = Write to load selected camera configuration  
Sapera  
In CamExpert, these parameters are available in the “Camera Information” tab, under the “Power-  
up Configuration” dialog box.  
GenICam features for Power-up Configuration:  
UserSetSelector = {Factory = 0, UserSet1 = 1}  
UserSetLoad = Loads the User Set specified by UserSetSelector to the camera and makes it  
active  
UserSetSave = Saves the User Set specified by UserSetSelector to the camera  
UserSetDefaultSelector = Selects the feature User Set to load at camera reset  
Sapera Supported Features List  
The Genie features and its currently set values can be read by a Sapera application. The Sapera tool CamExpert is  
an example of an application that reads and writes Genie parameters to control its operation.  
The following tables group the Genie features by their feature type—STRING, ENUM, INT32, and BOOL.  
Features may be read only (RO), read/write (RW), or write only (WO).  
Accessing Features with Sapera++ LT  
When working with Genie features, the SapAcqDevice class provides functions for accessing features from devices  
such as a GigE-Vision camera. The class also contains functions for sending commands and registering events to  
devices.  
SapAcqDevice::GetFeatureInfo returns information on a feature associated with a specified name or  
index.  
SapAcqDevice::SetFeatureValue writes a new value for a feature.  
All information about the feature is stored in a SapFeature class object.  
Refer to the Sapera++ LT Programmer's manual (OC-SAPM-SPPP0).  
68 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Feature Type STRING  
Feature Name  
Access  
Type  
Value  
Server Name  
RO  
RO  
RO  
RO  
RO  
RO  
RO  
RO  
RW  
STRING  
STRING  
STRING  
STRING  
STRING  
STRING  
STRING  
STRING  
STRING  
Genie_M640_1 (example)  
(number dependent on firmware version)  
DALSA  
Number of Features  
DeviceVendorName  
DeviceModelName  
DeviceVersion  
FirmwareVersion  
DeviceID  
Genie M640 (example)  
1452 (example)  
version 7630 (example)  
S1234567 (example)  
MACAddress  
00:01:0D:11:01:2A (example)  
Inspection-1 (user set example)  
DeviceUserID  
Feature Type ENUM  
Feature Name  
Access  
Type  
Values  
Interface  
RO  
RO  
ENUM  
ENUM  
GigE Vision  
DeviceScanType  
Area scan = 0  
Linescan = 1  
ColorType  
(dependent on camera model)  
RO  
ENUM  
Monochrome Sensor = 0  
CFA Bayer Sensor GR = 1  
CFA Bayer Sensor RG = 2  
CFA Bayer Sensor GB = 3  
CFA Bayer Sensor BG = 4  
RGB Sensor = 5  
ExposureMode  
RW  
RW  
RW  
RW  
RO  
ENUM  
ENUM  
ENUM  
ENUM  
ENUM  
Programmable = 1  
Pulse Controlled = 2  
ExposureAlignment  
BinningVertical  
BinningHorizontal  
Synchronous = 0  
Reset = 1  
Disabled = 1  
2 lines binned = 2  
Disabled = 1  
2 pixels binned = 2  
FlatFieldFormat  
(dependent on camera model)  
Mono 8 - Unsigned = 16844800  
Mono 9 - Unsigned = 16779520  
Mono 10 - Unsigned = 16779776  
RGB = 1124075520  
Flip  
RW  
RW  
ENUM  
ENUM  
Off = 0  
Horizontal = 1  
TestImageSelector  
Off = 0  
Grey Horizontal Ramp = 1  
Grey Vertical Ramp = 2  
Grey Diagonal Ramp Moving = 3  
Purity = 4  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LUTFormat  
(dependent on camera model)  
RO  
ENUM  
Mono 8 - Unsigned = 16844800  
Mono 8 - Signed = 285280256  
Mono 9 - Unsigned = 16779520  
Mono 9 - Signed = 285214976  
Mono 10 - Unsigned = 16779776  
Mono 10 - Signed = 285215232  
RGB = 1124075520  
TriggerSource  
RW  
RW  
ENUM  
ENUM  
Input 1 = 0  
Input 2 = 1  
Software = 2  
OutputSelectorOutput_1  
Open = 0  
Close = 1  
Strobe On: Start of Exposure = 2  
Pulse On: Valid Trigger = 4  
Pulse On: Invalid Trigger = 5  
Pulse On: Start of Readout = 6  
Pulse On: End of Readout = 7  
Pulse On: End of Acquisition = 8  
Pulse On: Input 1 = 9  
Pulse On: Input 2 = 10  
OutputSelectorOutput_2  
RW  
ENUM  
Open = 0  
Close = 1  
Pulse On: End of Exposure = 3  
Pulse On: Valid Trigger = 4  
Pulse On: Invalid Trigger = 5  
Pulse On: Start of Readout = 6  
Pulse On: End of Readout = 7  
Pulse On: End of Acquisition = 8  
Pulse On: Input 1 = 9  
Pulse On: Input 2 = 10  
PolarityInput_1  
PolarityInput_2  
PolarityOutput_1  
PolarityOutput_2  
PixelFormat  
RW  
RW  
RW  
RW  
RW  
ENUM  
ENUM  
ENUM  
ENUM  
ENUM  
Active High = 0  
Active Low = 1  
Active High = 0  
Active Low = 1  
Active Close = 0  
Active Open = 1  
Active Close = 0  
Active Open = 1  
Monochrome,  
8-bit = 17301505 (0x1080001)  
10-bit = 17825795 (0x1100003)  
Power-upConfig  
RW  
ENUM  
Factory Default = 0  
Camera Configuration 1 = 1  
SaveCameraConfigurationSelector  
LoadCameraConfigurationSelector  
RW  
RW  
ENUM  
ENUM  
Camera Configuration 1 = 1  
Factory Default = 0  
Camera Configuration 1 = 1  
NetworkConfigurationMode  
RW  
ENUM  
Automatic = 0  
Manual = 1  
70 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Feature Type INT32  
The feature list for type INT32 has an additional column 'Exponent' which defines the feature's native unit. This  
exponent value is used as a unit multiplier so that the feature value is expressed as an integer, not a decimal number.  
As an example from the following table, the Genie frame rate is 60000 with an exponent of 3. Therefore the  
frame rate native unit is mHz. The current value shown – 60000 mHz, is actually 60.000 Hz.  
Feature Name  
Access  
Type  
Exponent  
Sample Value  
DeviceMaxThroughput  
SensorWidth  
RO  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
Buffer  
Buffer  
Buffer  
INT32  
INT32  
INT32  
INT32  
INT32  
INT32  
EXP10: 0  
EXP10: 0  
EXP10: 0  
EXP10: 3  
EXP10: 0  
EXP10: 1  
EXP10: 6  
EXP10: 6  
EXP10: 0  
EXP10: 0  
EXP10: 6  
EXP10: 6  
EXP10: 6  
EXP10: 6  
EXP10: 6  
EXP10: 6  
EXP10: 0  
EXP10: 0  
EXP10: 0  
EXP10: 0  
EXP10: 0  
EXP10: 0  
EXP10: 6  
EXP10: 0  
EXP10: 3  
EXP10: 1  
18432000  
RO  
640  
SensorHeight  
RO  
480  
FrameRate (mHz)  
BlackLevel  
RW  
RW  
RW  
RW  
RW  
RW  
RO  
60000  
0
Gain  
0
ExposureTime (μS)  
TriggerDelayToIntegration (μS)  
FramesPerTrigger  
LUTNumberEntries  
DebounceInput_1 (μS)  
DebounceInput_2 (μS)  
PulseDelayOutput_1 (μS)  
PulseDurationOutput_1 (μS)  
PulseDelayOutput_2 (μS)  
PulseDurationOutput_2 (μS)  
Width  
16384  
0
1
256  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RO  
10  
10  
0
0
0
0
640  
Height  
480  
OffsetX  
0
OffsetY  
0
SaperaBufferFormat  
PixelSize  
16844800  
RO  
8
InterPacketDelay (μS)  
PacketSize  
RW  
RW  
RW  
RW  
RW  
RW  
RW  
RO  
0
1500  
500  
10  
HeartbeatTimeout (mS)  
MaximumPacketResend  
LUTData  
FlatFieldGainBuffer  
FlatFieldOffsetBuffer  
FlatFieldGainMin  
FlatFieldGainMax  
FlatFieldOffsetMin  
FlatFieldOffsetMax  
FlatFieldWidth  
EXP10: 0  
EXP10: 0  
EXP10: 0  
EXP10: 0  
EXP10: 0  
EXP10: 0  
(see note 1)  
(see note 1)  
(see note 1)  
(see note 1)  
(see note 1)  
(see note 1)  
RO  
RO  
RO  
RO  
FlatFieldHeight  
RO  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Note 1: not displayed in CamExpert; not saved in a camera configuration file (CCF)  
Feature Type BOOL  
Feature Name  
Access  
Type  
Value  
LUTEnable  
RW  
RW  
RW  
RW  
WO  
WO  
BOOL  
BOOL  
BOOL  
BOOL  
BOOL  
BOOL  
True/False  
True/False  
True/False  
True/False  
True/False  
True/False  
TriggerEnable  
TriggerSoftware  
FlatFieldEnable  
SaveCameraConfiguration  
LoadCameraConfiguration  
Feature Interdependence Diagrams  
The following diagrams describe operational feature availability which are dependent on user selected modes. These  
diagrams show what features are set to a value, and they show which feature parameters remain as user variables.  
Each diagram uses the following symbol set to indicate the dependent action type.  
gray box  
User Action  
Function Enabled  
The event “Feature Info Changed” is sent. Other feature properties might have changed too.  
Function Disabled  
The event “Feature Info Changed” is sent. Other feature properties might have changed too.  
Forced Value  
The event “Feature Value Changed” is sent if the forced value is different from the previous value.  
Set Max Value  
The event “Feature Info Changed” is sent if the new value is different than the previous value.  
Set Max Value  
The event “Feature Value Changed” is sent if the new range causes the value to be not within the  
valid range. The feature is usually set to the new maximum. When the maximum range increases,  
the “Feature Value Changed” event is never set.  
72 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Trigger Enable - TRUE  
Trigger Enable  
Trigger Source  
TRUE  
Exposure Mode  
Programmable  
Software  
Input 1  
Input 2  
Exposure Time  
Exposure Mode  
Programmable  
Pulse Controlled  
Exposure Time  
Exposure Time  
Trigger Delay to Integration  
Exposure Alignment  
Synchronous  
Reset  
Exposure Time  
Frame Rate  
Software Trigger  
Frame Per Trigger  
Trigger Enable - FALSE  
Trigger Enable  
Trigger Source  
FALSE  
Exposure Mode  
Programmable  
Exposure Time  
Trigger Delay to Integration  
Exposure Alignment  
Frame Rate  
Exposure Time  
Software Trigger  
Frame Per Trigger  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Output Selector  
Output X Selector  
Open  
Output X Pulse Delay  
Output X Pulse Duration  
Output X Polarity  
Close  
Strobe On: Start of Exposure  
Pulse On: End of Exposure  
Pulse On: Valid Trigger  
Pulse On: Invalid Trigger  
Pulse On: Start of Readout  
Pulse On: End of Readout  
Pulse On: End of Acquisition  
Output X Pulse Delay  
Output X Pulse Duration  
Output X Polarity  
Vertical Binning  
Vertical Binning  
1 Line (Off)  
Buffer Height  
Buffer Top  
2 Lines  
Buffer Top  
Buffer Height  
Buffer Top  
Frame Rate  
Exposure Time  
Buffer Height  
Horizontal Binning  
Flat Field Enable  
Buffer Width  
Horizontal Binning  
1 Row (Off)  
2 Rows  
Buffer Left  
Buffer Width  
Buffer Left  
Buffer Left  
Buffer Width  
74 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Pixel Format  
Pixel Format  
8-Bit  
SaperaBufferFormat  
PixelSize  
10-bit  
LUTFormat  
LUTNumberEntries  
FlatFieldEnable  
Network Configuration Mode  
Network Configuration Mode  
Automatic  
Packet Size  
Optimize  
Heartbeat Timeout  
Inter-Packet Delay  
Max Packet Resend  
Manual  
Packet Size  
Heartbeat Timeout  
Inter-Packet Delay  
Max Packet Resend  
Genie Monochrome Series-GigE Vision Camera  
Operational Reference 75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
76 Operational Reference  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network Tools  
IP Configuration Mode Details  
The following descriptions provide more information on the IP configuration modes supported by Genie. In general  
automatic IP configuration assignment is sufficient for most Genie installations.  
Link-Local Address (LLA)  
LLA is also known as Auto-IP. It is used for unmanaged networks including direct connections from a GigE  
Vision device to a dedicated NIC.  
A subnet configured with LLA cannot send packets across routers but only via Ethernet switches.  
LLA is the recommended scheme when only one NIC is connected to GigE cameras. LLA is fully automatic  
requiring no user input.  
Ensure only one NIC is using LLA on your PC, otherwise IP conflicts will result.  
The NIC will automatically assign a random IP address within the 169.254.x.x subnet. The LLA protocol  
ensures there are no conflicts with other devices through an arbitration scheme.  
The Windows NIC configuration must be set to DHCP (the typical default case) and no DHCP server must be  
present on the network. Otherwise, an IP address gets assigned by the DHCP server. Windows will turn to LLA  
when no DHCP server answers requests coming from the NIC.  
Windows takes up to 1 minute to obtain an LLA IP address. With Windows XP, with no DHCP server  
involved, the network adapter icon in the system tray (in Windows XP) typically shows "limited or no  
connectivity".  
This is normal (see Microsoft KB article #892896) and indicates that the network does not have connectivity  
beyond routers.  
Windows and Genie are still running the DHCP process in the background. If a DHCP server becomes  
available on the network, the NIC will get a DHCP assigned IP address for the connected device but  
connections on the LLA IP address will be lost.  
Important: If the host system has multiple NIC devices configured with LLA, then the communication stack  
cannot accurately resolve which NIC to forward an IP packet on the 169.254 segment. Limit the number of NIC  
configured using LLA to one interface. See "GigE Server Warning Example 1a: IP error with multiple NICs"  
on page 103 for additional information.  
Use the DALSA Network tool to change the Genie from the default DHCP/LLA mode to Persistent IP mode  
when required, such as when there are multiple NIC devices with Genie connected to each. Note that DALSA  
recommends DHCP/LLA as the mode of operation where a switch is used to connect multiple Genie devices.  
Genie Monochrome Series-GigE Vision Camera  
Network Tools 77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DHCP (Dynamic Host Configuration Protocol)  
This Genie IP configuration mode requires a DHCP server to allocate an IP address dynamically. The Genie  
must be configured to have DHCP enabled. This is the factory default settings.  
The DHCP server is part of a managed network. Windows XP itself does not provide a DHCP server function.  
A dedicated DHCP server is required. Open-source DHCP server software can be found on the Internet, but  
they might not provide the same level of functionality as commercial-grade DHCP servers.  
A DHCP server is recommended where there are multiple NIC ports with multiple GigE Vision devices  
attached. Each NIC ports must use a different subnet to avoid IP address conflicts (see "GigE Server Warning  
Under Windows, a NIC is configured in DHCP mode by default. If no DHCP server is present on a given  
subnet, Windows will revert to LLA as explained in the section above.  
Ensure that a different subnet is assigned to each NIC on the network. Typical ranges are 192.200.x.x or  
10.10.x.x for internal networks.  
Persistent IP  
This protocol is only suggested if the user fully controls the assignment of IP addresses on the network and a  
GigE Vision camera is connected beyond routers.  
The GigE Vision camera is forced a static IP address. The NIC IP address must use the same subnet otherwise  
the camera is not accessible.  
If the Genie camera is connected to a network with a different subnet, it cannot be accessed.  
The DALSA network configuration tool is used to set a persistent IP address.  
An example of a Persistent IP address assignment:  
Persistent IP = 192.200.1.1  
Subnet Mask = 255.255.0.0  
Default Gateway = 0.0.0.0  
Warning: an incorrect IP address assignment might make it impossible to connect to the camera. In such a case  
the DALSA network configuration tool includes a function to recover a Genie camera with an unknown  
persistent IP and set the Genie to the factory default setting, i.e. DHCP/LLA mode. The Genie MAC address  
must be known to use this function. See "Recovering a Camera with an Unknown Persistent IP" on page 82 and  
For GigE Vision applications the FORCEIP command is used to force a new persistent IP or to change the IP  
configuration protocol. The Genie MAC address must be known to use the FORCEIP command.  
78 Network Tools  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Network Configuration Tool  
The Network Configuration tool provides information on all network adapters installed in the system and any  
connected GigE Vision devices. For the Genie, the tool allows a simple method to assign a User-Defined name and  
also to set a Persistent IP address instead of the default DHCP/LLA assigned IP address. Using this tool, Genie  
network configurations can be easily made without having to use any Windows Control Panel application.  
Important: Any changes made with this tool will update the Genie flash memory. Do not remove power from the  
Genie camera for a minimum 10 seconds. Then cycle the Genie power to load the new flash settings.  
Quick Genie Network Configuration  
Start the Network Configuration program from the windows start menu: Start•Programs•DALSA•Sapera  
Network Imaging Package•DALSA Network Configuration Tool.  
The left display window will show all installed network adapters and any connected Genie camera.  
Click on a Genie camera to see information such as MAC address, current IP address, serial and firmware  
numbers.  
Click in the User Defined Name edit box and change the Genie name as required. Click on the Update button to  
write into the Genie memory.  
Genie Network Information  
Select the Device Configuration tab to switch from the default IP configuration mode DHCP/LLA to  
Persistent IP mode (only if required).  
With Persistent IP mode selected enter the desired IP address, subnet mask, and default gateway.  
Important: do not forget the persistent IP address you assign, else the camera can not be controlled.  
Genie Monochrome Series-GigE Vision Camera  
Network Tools 79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie IP Configuration  
System Information and Configuration  
Select the system icon (the computer symbol) in the left pane to display current system information which may be  
required when documenting Genie installations. There are no user changeable fields in the System Information tab.  
In the right hand pane click on the System Configuration tab. By default the Sapera GigE Server is added to the  
Windows Firewall exception list. This function is performed automatically when the Genie software package is  
installed. This ensures the Windows Firewall remains active (if it was enabled) without having to individually put  
each Genie application program in the exception list.  
System Firewall Configuration  
If the computer is using a different firewall software package, refer to that firewall's software manual to allow the  
Sapera GigE Server to have access through it.  
Alternatively, it is possible to exclude a specified NIC from using the firewall. The NIC dedicated to the Genie  
camera does not need Windows firewall. See "Disabling Windows Firewall" on page 107 for details on excluding a  
NIC from firewall settings.  
80 Network Tools  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Network Card Information and Configuration  
Select a network card icon in the left pane to see the NIC configuration parameters. The Network Configuration tool  
ensures that no two NIC devices installed in the computer are on the same subnet, since that would create a conflict.  
A warning message is displayed in such a case, indicating that a settings change is required for one of the NIC.  
NIC Information  
NIC IP and Network Imaging Driver Assignment  
For each NIC, it is possible to configure the IP configuration mode (either DHCP/LLA or Persistent IP) if required  
via the NIC Configuration tab.  
Warning: Changing the NIC IP address may put it on a different subnet than the Genie. Changing the NIC IP  
configuration first might cause the case where the camera becomes inaccessible from the NIC.  
The proper sequence is to first change the camera IP configuration then change the NIC IP.  
Genie Monochrome Series-GigE Vision Camera  
Network Tools 81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
After installation, all system NIC devices have the Sapera Network Imaging driver enabled. Only the NIC  
connected to a Genie camera requires the Network Imaging driver enabled to capture images from Genie. The  
Network Imaging driver streams image data efficiently to image buffers.  
Select other NIC devices in the system and disable the Network Imaging Driver if they are not used with a Genie  
camera.  
Recovering a Camera with an Unknown Persistent IP  
When a Genie camera has been configured with a persistent IP address, that camera can not be controlled if its IP  
address has been lost or forgotten. The DALSA Network Configuration tool provides a function to recover cameras  
and reset them back to the DHCP/LLA mode. The camera can also be set to a new persistent IP address immediately  
if required.  
Important: To recover a Genie camera, the camera MAC address must be known. DALSA ships all Genie  
cameras with a label stating its serial number and MAC address. Additionally the NIC connected to the Genie  
must be configured for LLA mode.  
To recover a Genie:  
Start the Network Configuration program from the windows start menu: Start•Programs•DALSA•Network  
Interface•DALSA Network Configuration Tool.  
From the menu bar click on Advanced and then on Recover Camera.  
On the dialog enter the camera MAC address and click the Recover Camera button.  
Camera Recovery Dialog  
82 Network Tools  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
If the camera requires a persistent IP address, select the bullet to assign a persistent IP immediately with  
recovery. Enter the new IP address and click on Recover Camera.  
Important: Any changes made with this tool will update the Genie flash memory. Do not remove power from the  
Genie camera for a minimum 10 seconds.  
Sapera GigE Server Details  
This section provides additional details on the GigE Server not covered in the Genie installation section of this  
manual. Generally the Genie automatic installation requires no user intervention.  
The Sapera GigE Server implements the GigE Vision Control Protocol (GVCP). This provides the interface to  
generate GVCP messages to control and configure a GigE Vision device.  
GigE Server handles the heartbeat messages, allowing an application in development, to be single-stepped  
while in debug mode, without loss of the camera connection.  
GigE Server is a single application going through the firewall. This simplifies firewall settings as only this  
application needs to be listed in the firewall exceptions.  
The GigE Server periodically rescans the network to discover any new camera that might have been added to  
the network. This will also identify devices removed.  
When required, it is possible to disabled the GigE server. A Sapera application will then directly be linked to  
the library responsible for GigE Vision control channel communications. This can be used to minimize inter-  
process communications.  
The GigE Server Status window provides valuable information about the GigE Vision devices present on your  
system (see "Troubleshooting" on page 101).  
Genie Monochrome Series-GigE Vision Camera  
Network Tools 83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Status Window Description  
User Name  
Manufacturer  
Model  
User assigned identification  
Manufacturer for this device  
GigE Vision device model  
Device serial number  
Serial Number  
Firm Ver  
Device firmware revision number  
Device MAC address  
MAC adddress  
Camera IP  
NIC IP  
Device current IP address  
NIC IP associated with the GigE server  
Network driver status  
Filter driver  
MaxPktSize  
Largest packet size that should be used for image streaming.  
This is found using the Test Packet mechanism of GigE Vision.  
ABI  
Sapera Application Binary Interface to communicate with the device  
General device status  
Status  
Note that the user can resize columns or drag any column header to reorder the displayed  
information. Column order is automatically saved in an .ini file when the Genie Framework is  
uninstalled and reinstalled.  
Creating a Status Report  
Before contacting DALSA technical support, the user should review the Troubleshooting section of this manual  
(see "Troubleshooting" on page 101). Most installation, configuration, and imaging issues are documented along  
with their solutions.  
To aid technical support, the tool can save a network configuration report. From the File menu select “Save current  
status”. You will be prompted for a filename for the report text file. This file should always be sent with any request  
for technical support.  
84 Network Tools  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Sapera CamExpert Guide  
Using CamExpert with Genie Monochrome Cameras  
CamExpert is the camera interfacing tool supported by the Sapera library. When used with a Genie camera,  
CamExpert allows a user to test all Genie operating modes. Additionally CamExpert saves the Genie user settings  
configuration to the camera or saves multiple configurations as individual camera parameter files on the host system  
(*.ccf).  
An important component of CamExpert is its live acquisition display window which allows immediate verification  
of timing or control parameters without the need to run a separate acquisition program.  
For context sensitive help, click on the  
button then click on a camera configuration parameter. A short  
description of the configuration parameter will be shown in a popup. Click on the  
for more descriptive information on CamExpert.  
button to open the help file  
The central section of CamExpert provides access to the Genie parameters. Five tabs group Genie parameters  
depending on their type as described in the summary below. Each Genie configuration parameter is described in  
detail following the summary.  
Displays Genie firmware details such as camera model, version, serial number  
and MAC address. Users can set the User ID and set the power-up  
configuration mode.  
Camera Information  
Sensor Parameters  
Displays both static and variable sensor parameters that are Genie model  
specific. Variable parameters control Genie exposure, binning, gain and  
exposure controls. The internal test image is selected here.  
Provides controls for trigger source and I/O pin configuration.  
Provides controls for buffer pixel depth, image size and cropping.  
Provides advance controls to optimize the network connection.  
I/O Controls  
Image Buffer and ROI  
GigE Vision  
Genie Monochrome Series-GigE Vision Camera  
Sapera CamExpert Guide 85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CamExpert Panes  
The CamExpert application uses 5 windows to simplify choosing and configuring camera files or acquisition  
parameters for the installed device.  
Device pane: View and select from any installed Sapera acquisition device. Once a device is selected  
CamExpert will only present acquisition parameters applicable to that device.  
Parameters pane: Allows viewing or changing all acquisition parameters supported by the acquisition device.  
CamExpert displays parameters only if those parameters are supported by the installed device. This avoids  
confusion by eliminating parameter choices when they do not apply to the hardware in use.  
Display pane: Provides a live or single frame acquisition display. Frame buffer parameters are shown in an  
information bar above the image window.  
86 Sapera CamExpert Guide  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Control Buttons: The Display pane includes CamExpert control buttons. These are:  
Acquisition control button:  
Click once to start live grab, click again to stop.  
Single frame grab:  
Click to acquire one frame from device.  
Software trigger button:  
With the I/O control parameters set to Trigger Enabled / Software Trigger  
type, click to send a single software trigger command.  
CamExpert display controls:  
(these do not modify the frame buffer data)  
Stretch image to fit, set image display to original size, or zoom the image to  
any size and ratio.  
Histogram / Profile tool:  
Select to view a histogram or line/column profile during live acquisition.  
Camera pane: Allows selecting any camera file that is included with the Sapera installation. Only camera files  
supported by the selected acquisition device. When there is more then one acquisition server, such as  
monochrome and RGB, selecting an inappropriate camera file will produce a message prompting you to select  
the correct acquisition server.  
Output pane: Displays messages from CamExpert or the device driver.  
Video Status bar: Located on the lower right of the CamExpert window, color coded camera signal status  
information is displayed. Green for valid signals detected, red for missing or incorrect signals. Video status  
items may differ with different devices.  
Most of these panes can be hidden via the menu bar view command. Typically after selecting an acquisition device  
and loading a camera file, the Device and Camera windows can be closed.  
CamExpert LUT Controls  
The Lookup Table dialog allows you to configure the LUT if it is available on the device. Genie monochrome  
cameras support an 8-bit or 10-bit LUT. To open this dialog, use the Pre-Processing > Lookup Table > Setting  
menu command. Note that you must first enable the Lookup Table, otherwise the Setting command will be grayed-  
out.  
To select the type of LUT to use, click the LUT Mode Value field; a drop-down list box displays the available  
modes. The Lookup Table dialog displays a graph of the input and output values for the selected LUT. These are  
CamExpert common examples for LUT operations. A Sapera application can program the Genie LUT for any  
required LUT operation. See "Lookup Table (LUT)" on page 56 for Genie LUT support.  
Genie Monochrome Series-GigE Vision Camera  
Sapera CamExpert Guide 87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10-bit Invert LUT  
CamExpert available LUT examples are briefly described below. The LUT function graphic simplifies  
understanding the operation especially when user settings modify the LUT function.  
Normal (default): modifies all LUT entries using a linear mapping such that a gray level input is equal to  
the output  
Arithmetic operation: modifies all LUT entries using an arithmetic operation  
Binary pattern: modifies some LUT entries based on a binary pattern  
Boolean operation: modifies all LUT entries using a Boolean operation  
Gamma correction: modifies all LUT entries using Gamma correction function  
Linear invert: modifies all LUT entries using a linear mapping with a negative slope  
Position shift: modifies LUT entries with a zero position offset  
Bit shift: modifies LUT entries with a binary bit shift  
Slope within range: modifies part of a LUT with a linear mapping  
Single Threshold: modifies all LUT entries using a threshold operation  
Double Threshold: modifies all LUT entries using a dual level threshold operation  
88 Sapera CamExpert Guide  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specifications  
Mechanical Specifications  
The figure below defines the Genie family mechanical specifications. Additional notes follow.  
Genie Monochrome Series-GigE Vision Camera  
Technical Specifications 89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Notes:  
Genie supports a screw lock Ethernet cable (see "Ruggedized RJ45 Ethernet Cables" on page 97).  
For information on Genie lens requirements see "Optical Considerations" on page 93.  
Lens flange focal distance = 17.52 mm.  
The camera top also has four mounting holes in identical locations.  
Connectors  
A single RJ45 Ethernet connector for control and video data to the host Gigabit NIC. Genie is available with  
an industrial case supporting a screw lock Ethernet cable (see "Ruggedized RJ45 Ethernet Cables" on page 97).  
A single 12-pin Hirose male connector for power, trigger and strobe signals. The suggested female cable  
mating connector is Hirose model HR10A-10P-12S.  
12-Pin Hirose Connector Signal Details  
The following figure shows the pinout identification when looking at the Genie camera 12-pin male Hirose  
connector. The table below the figure lists the Genie I/O signal specifications.  
Pin  
Direction  
Genie Signal (see details below)  
Notes  
1
-
Power GND  
2
-
+12V DC power supply  
10% tolerance  
3
Out  
Output 1 -  
4
Out  
Output 1 +  
5
In  
Input 1 -  
RS422- or TTL GND  
RS422+ or TTL  
6
In  
Input 1 +  
7
Out  
Output 2 + / Strobe +  
8
Out  
Output 2 - / Strobe -  
9
-
Reserved  
10  
-
Reserved  
11  
12  
In  
In  
Input 2 +  
RS422+ or TTL  
Input 2 -  
RS422- or TTL GND  
improves EMI shielding  
shell / shield  
via cable shield  
Genie chassis connects to supply earth ground  
90 Technical Specifications  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie Signal Electrical Details  
Power Supply (pin 2): +12V DC nominal.  
Operating tolerance +10% to –10%.  
Over voltage and reverse voltage protection circuit built in. The protection circuit is reset by shutting down or  
disconnecting the power supply.  
The 12-pin Hirose male connector shell and cable shield should connect to the supply earth ground to improve  
EMI shielding.  
External Inputs  
Opto-coupled (2V to 12V, 2mA minimum) with internal current limit.  
RS422 or TTL signal type.  
Used as trigger or integration control.  
External signal polarity selected via configuration parameter.  
User programmable debounce time from 1 to 255µs.  
3.3V  
example  
TTL external  
V+  
Genie  
4.7K  
device  
680  
Event  
Signal  
Buffer  
driver  
Trigger  
Debounce  
IN+  
IN-  
IN  
.01µf  
example  
74HC244  
Fairchild  
HMHA281R  
Hirose 12  
connector  
External Input Detail with an Example Signal Driver  
The opto-coupler is typically a Fairchild HMHA281 with the following characteristics.  
Input Electrical Parameter Description  
Value  
Voltage threshold to turn OFF  
Voltage threshold to turn ON  
Minimum input current to turn ON  
Maximum input current  
0.8 V  
2 V  
2 mA  
50 mA  
30 us  
13 V  
Minimum input pulse width to turn ON  
Maximum input voltage  
Genie Monochrome Series-GigE Vision Camera  
Technical Specifications 91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
External Outputs  
Programmable output mode such as strobe, event notification, etc. (see "Output Control via Sapera LT or  
GenICam Applications" on page 56).  
User Genie  
side side  
75  
680  
OUT+  
OUT  
OUT-  
NEC PS2805-1  
Hirose-12  
Connector  
pins  
The opto-coupler is typically a NEC PS2805-1 with the following characteristics.  
Output Electrical Parameter Description  
Value  
Maximum voltage difference  
13 V  
12mA  
100 us  
12 µs  
40 µs  
Maximum current through opto-coupler  
Minimum output pulse width  
Maximum switch closure transition time  
Maximum switch open transition time  
RJ45 LAN Ethernet Connector Details  
The RJ45 LAN connector has two LEDs for network status conditions.  
The LED color codes are as follows.  
Network Connection  
Network Activity  
Green  
100Mbps  
Off  
no network activity  
typically blinking – active  
Orange  
1000Mbps  
Yellow  
Network Connection  
Network Activity  
The Genie LAN connector is a standard Ethernet socket. Use CAT5e or CAT6 certified Ethernet cables. CAT5e  
cable is rated for 100 MHz spectral bandwidth but CAT6 cable is rated for a 200 MHz spectral bandwidth with less  
signal attenuation, therefore strongly recommended for long connection lengths.  
The interconnection Ethernet cable can be either Straight Through or Crossover cable type. The Gigabit Ethernet  
standard for devices defines that they will auto-negotiate send and receive channels, eliminating the need for users  
to use a specific Ethernet cable type.  
92 Technical Specifications  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Camera Status LED  
The Genie has one multicolor LED to provide a simple visible indication of the operational status of the camera.  
When more than one condition is active, the LED color indicates the condition with the highest priority. The  
following table summarizes the LED states and corresponding camera status.  
LED State  
Definition  
LED is off  
No power to the camera  
Steady Red  
Camera not initialized  
Slow Flashing Red  
Fast Flashing Red  
Slow Flashing Blue  
Fast Flashing Blue  
Steady Blue  
Camera initialization problem  
Camera is too hot  
Waiting for an IP address  
Ethernet cable disconnected (no link)  
IP address assigned; no application connected to the camera  
Application connected  
Steady Green  
Slow Flashing Green  
Fast Flashing Green  
Triggered acquisition in progress  
Free running acquisition in progress  
Optical Considerations  
This section provides an overview to illumination, light sources, filters, lens modeling, and lens magnification. Each  
of these components contribute to the successful design of an imaging solution.  
Illumination  
The amount and wavelengths of light required to capture useful images depend on the particular application. Factors  
include the nature, speed, and spectral characteristics of objects being imaged, exposure times, light source  
characteristics, environmental and acquisition system specifics, and more. The DALSA Web site,  
http://vfm.dalsa.com/, provides an introduction to this potentially complicated issue. Click on the Application  
Support link and then select the CCD Technology Primer. Review “Radiometry and Photo Responsivity” along  
with other sections of interest.  
It is often more important to consider exposure than illumination. The total amount of energy (which is related to  
the total number of photons reaching the sensor) is more important than the rate at which it arrives. For example,  
5μJ/cm2 can be achieved by exposing 5mW/cm2 for 1ms just the same as exposing an intensity of 5W/cm2 for 1μs.  
Light Sources  
Keep these guidelines in mind when selecting and setting up light source:  
LED light sources are relatively inexpensive, provide a uniform field, and longer life span compared to other  
light sources. However, they also require a camera with excellent sensitivity.  
Halogen light sources generally provide very little blue relative to infrared light (IR).  
Fiber-optic light distribution systems generally transmit very little blue relative to IR.  
Genie Monochrome Series-GigE Vision Camera  
Technical Specifications 93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Some light sources age such that over their life span they produce less light. This aging may not be uniform—a  
light source may produce progressively less light in some areas of the spectrum but not others.  
Filters  
CCD cameras are extremely responsive to infrared (IR) wavelengths of light. To prevent infrared from distorting the  
images you scan, use a “hot mirror” or IR cutoff filter that transmits visible wavelengths but does not transmit  
wavelengths over 750nm. Examples are the Schneider Optics™ B+W 489, which includes a mounting ring, the  
CORION™ LS-750, which does not include a mounting ring, and the CORION™ HR-750 series hot mirror.  
Lens Modeling  
Any lens surrounded by air can be modeled for camera purposes using three primary points: the first and second  
principal points and the second focal point. The primary points for a lens should be available from the lens data  
sheet or from the lens manufacturer. Primed quantities denote characteristics of the image side of the lens. That is, h  
is the object height and his the image height.  
The focal point is the point at which the image of an infinitely distant object is brought to focus. The effective focal  
length (f) is the distance from the second principal point to the second focal point. The back focal length (BFL) is  
the distance from the image side of the lens surface to the second focal point. The object distance (OD) is the  
distance from the first principal point to the object.  
Primary Points in a Lens System  
Magnification and Resolution  
The magnification of a lens is the ratio of the image size to the object size:  
Where m is the magnification, h’ is the image height (pixel size)  
and h is the object height (desired object resolution size).  
h'  
m =  
h
By similar triangles, the magnification is alternatively given by:  
f '  
m =  
OD  
These equations can be combined to give their most useful form:  
This is the governing equation for many object and image plane  
parameters.  
h'  
f '  
=
h
OD  
94 Technical Specifications  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Example: An acquisition system has a 512 x 512 element, 10μm pixel pitch area scan camera, a lens with an  
effective focal length of 45mm, and requires that 100μm in the object space correspond to each pixel in the image  
sensor. Using the preceding equation, the object distance must be 450mm (0.450m).  
OD = 450mm(0.450m)  
10μm 45mm  
=
100μm  
OD  
Sensor Handling Instructions  
This section reviews proper procedures for handling, cleaning, or storing the Genie camera. Specifically the Genie  
CCD sensor needs to be kept clean and away from static discharge to maintain design performance.  
Electrostatic Discharge and the CCD Sensor  
Cameras contain charge-coupled device (CCD) image sensors, which are metal oxide semiconductor (MOS) devices  
and are susceptible to damage from electrostatic discharge (ESD).  
Electrostatic charge introduced to the sensor window surface can induce charge buildup on the underside of the  
window that cannot be readily dissipated by the dry nitrogen gas in the sensor package cavity. When charge buildup  
occurs, surface-gated photodiodes (SGPDs) may exhibit higher image lag or a highly non-uniform response, with  
some pixels displaying a much higher response when the sensor is exposed to uniform illumination. The charge  
normally dissipates within 24 hours and the sensor returns to normal operation.  
Important: Charge buildup will affect the camera’s flat-field correction calibration. To avoid an erroneous  
calibration, ensure that you perform flat-field correction only after a charge buildup has dissipated over 24 hours.  
Protecting Against Dust, Oil and Scratches  
The CCD window is part of the optical path and should be handled like other optical components, with extreme  
care.  
Dust can obscure pixels, producing dark patches on the sensor response. Dust is most visible when the illumination  
is collimated. The dark patches shift position as the angle of illumination changes. Dust is normally not visible when  
the sensor is positioned at the exit port of an integrating sphere, where the illumination is diffuse.  
Dust can normally be removed by blowing the window surface using a compressed air blower, unless the dust  
particles are being held by an electrostatic charge, in which case either an ionized air blower or wet cleaning is  
necessary.  
Oil is usually introduced during handling. Touching the surface of the window barehanded will leave oily residues.  
Using rubber finger cots and rubber gloves can prevent oil contamination. However, the friction between the rubber  
and the window may produce electrostatic charge that may damage the sensor.  
Scratches can be caused by improper handling, cleaning or storage of the camera. When handling or storing the  
Genie camera without a lens, always install the C-mount protective cap. Scratches diffract incident illumination.  
When exposed to uniform illumination, a sensor with a scratched window will normally have brighter pixels  
adjacent to darker pixels. The location of these pixels changes with the angle of illumination.  
Genie Monochrome Series-GigE Vision Camera  
Technical Specifications 95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cleaning the Sensor Window  
Even with careful handling, the sensor window may need cleaning. The following steps describe various cleaning  
techniques to clean minor dust particles to accidental finger touches.  
Use compressed air to blow off loose particles. This step alone is usually sufficient to clean the sensor window.  
Avoid moving or shaking the compressed air container and use short bursts of air while moving the camera in  
the air stream. Agitating the container will cause condensation to form in the air stream. Long air bursts will  
chill the sensor window causing more condensation. Condensation, even when left to dry naturally, will deposit  
more particles on the sensor.  
When compressed air cannot clean the sensor, Dalsa recommends using lint-free ESD-safe cloth wipers that do  
not contain particles that can scratch the window. The Anticon Gold 9”x 9” wiper made by Milliken is both  
ESD safe and suitable for class 100 environments. Another ESD acceptable wiper is the TX4025 from  
Texwipe.  
An alternative to ESD-safe cloth wipers is Transplex swabs that have desirable ESD properties. There are  
several varieties available from Texwipe. Do not use regular cotton swabs, since these can introduce static  
charge to the window surface.  
Wipe the window carefully and slowly when using these products.  
Environment  
Ambient Temperature:  
0° to 45° C (operation)  
0° to 70° C (storage)  
Relative Humidity:  
5% to 90% non-condensing (operating)  
0% to 95% (storage)  
96 Technical Specifications  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ruggedized RJ45 Ethernet Cables  
Components Express Inc. has available an industrial RJ45 CAT6 cable that on one end has a molded shroud  
assembly with top/bottom thumbscrews, while the other end has a standard RJ45. This cable is recommended when  
Genie is installed in a high vibration environment.  
Contact sales at DALSA for availability of Genie with female mounts for this secure Ethernet cable.  
Components Express, Inc. (CEI)  
10330 Argonne Woods Drive, Suite 100  
Woodridge, IL 60517-4995  
Phone: 630-257-0605 / 800.578.6695 (outside Illinois)  
Fax: 630-257-0603  
All cables made in U.S.A. – all cables RoHS compliant.  
CAT6 certified (tested for near end / far end crosstalk and return loss).  
IGE-3M (3meters)  
IGE-10M (10meters)  
IGE-25M (25meters)  
IGE-50M (50meters)  
IGE-100M (100meters)  
Genie Monochrome Series-GigE Vision Camera  
Technical Specifications 97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Computer Requirements for Genie Cameras  
The following information is a guide to computer and networking equipment required to support the Genie camera  
at maximum performance. The Genie camera series complies with the current IPv4 Internet Protocol, therefore  
current Gigabit Ethernet (GigE) equipment should provide trouble free performance.  
Host PC System  
Pentium 4 system (or AMD equivalent) with 512 MB system memory.  
System motherboard without an embedded graphic card. Avoid using onboard video cards as they may  
compete with other components for shared memory.  
High performance video card as either an AGP bus or PCI Express bus.  
Operating System: Windows 2000 SP1 and Windows XP are supported.  
Network Adapters  
GigE network adapter (either add on card or on motherboard). The Intel PRO/1000 MT adapter is an  
example of a high performance NIC. Typically a system will need an Ethernet GigE adapter to supplement  
the single NIC on the motherboard.  
PCI Express adapters will outperform PCI adapters.  
Network adapters that support Jumbo Frames will outperform adapters with fixed packet size frames.  
Laptop Information  
Laptop computers with built in GigE network adapters may still not be able to stream full frame rates  
from Genie. Thorough testing is required with any laptop computer to determine the maximum frame rate  
possible (see "Laptop Computer Networking Issues" on page 111).  
Ethernet Switch Requirements  
When there is more than one device on the same network or a camera-to-PC separation greater than 100 meters, an  
Ethernet switch is required. Since the Genie GigE camera complies with the Internet Protocol, it should work with  
all standard Ethernet switches. However, switches offer a range of functions and performance grades, so care must  
be taken to choose the right switch for a particular application. The following switches are expected to work with  
the camera but manufacturers may change specifications and features at anytime:  
SMC (http://www.smc.com/) TigerSwitch 86xxT family  
Features Layer 2 with IGMP v2.0 that supports jumbo frames and multicast.  
SMC EZ Switch (SMCGS8): low cost switch supporting jumbo frames.  
3COM (http://www.3com.com/) 3C1740x (3800 Family):  
Features Layer 2 with IGMP v2.0 that supports multicast.  
3COM 3C1770x (4900 Family):  
Features Layer 2 non-blocking switch that converts multicast into a broadcast.  
Dlink (http://www.dlink.com/) DGS-10xxTx 10/100/1000 family:  
Features Layer 2 unmanaged switch that converts multicast into a broadcast.  
DGS-3308FG & DGS-3308-TG  
Features Layer 3 non-blocking switch that supports multicast.  
Cisco (http://www.cisco.com/) WS-C3750G-12S-S:  
Features: Layer 3 switch that supports multicast.  
98 Technical Specifications  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ethernet to Fiber-Optic Interface Requirements  
In cases of camera-to-PC separations of more than 100 meters but an Ethernet switch is not desired, a fiber-optic  
media converter can be used. The FlexPoint GX from Omnitron Systems (http://www.omnitron-systems.com/)  
converts GigE to fiber transmission and vice versa. It supports multimode (MM) fiber over distances of up to 220 m  
(720 ft.) and single-mode (SM) fiber up to 65 km (40 mi.) with SC, MT-RJ, or LC connector types.  
Important: The inclusion in this manual of GigE to fiber-optic converters does not guarantee they will meet  
specific application requirements or performance. The user must evaluate any supplemental Ethernet equipment.  
Genie Monochrome Series-GigE Vision Camera  
Technical Specifications 99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EC & FCC Declaration of Conformity  
100 Technical Specifications  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Troubleshooting  
Overview  
In rare cases an installation may fail or there are problems in controlling and using the Genie camera. This section  
highlights issues or conditions which may cause installation problems and additionally provides information on  
computers and network adapters which have caused problems with Genie. Emphasis is on the user to perform  
diagnostics with the tools provided and methods are described to correct the problem.  
The GigE Server status provides visual information on possible Genie problems. The three states are shown in the  
following table. Descriptions of possible conditions causing an installation or operational problem follow. Note that  
even a Genie installation with no networking issue may still require optimization to perform to specification.  
Device Not Available  
Device IP Error  
Device Available  
GigE Server  
Tray Icon:  
Note: It will take  
a few seconds for  
the GigE Server  
A red X will remain over the  
GigE server tray icon when the shows a warning when a device when the Genie device is  
Genie device is not found. This is connected but there is some  
The GigE server tray icon  
The GigE server tray icon  
found. The Genie has obtained  
an IP address and there are no  
network issues. Optimization  
may still be required to  
to refresh its state indicates a network issue where type of IP error.  
after any change.  
there is no communication with  
Genie.  
maximize performance.  
Problem Type Summary  
Genie problems are either installation types where the Genie is not found on the network or setup errors where the  
Genie device is found but not controllable. Additionally a Genie may be properly installed but network optimization  
is required for maximum performance. The following links jump to various topics in this troubleshooting section.  
Genie Monochrome Series-GigE Vision Camera  
Troubleshooting 101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Device Not Available  
A red X over the GigE server tray icon indicates that the Genie device is not found. This indicates either a major  
camera fault or condition such as disconnected power, or a network issue where there is no communication.  
Review the section "Installation Overview & Preparations" on page 18 to verify required installation steps.  
See "Verifying Network Parameters" on page 115 to review networking details.  
See "VPN Driver Interference" on page 115 if using Genie Framework previous to release 1.20.  
Device IP Error  
The GigE server tray icon shows a warning with IP errors. Review the following topics on network IP problems to  
identify and correct the condition.  
Device Available but with Operational Issues  
A properly installed Genie with no network issues may still not perform optimally. Operational issues concerning  
cabling, Ethernet switches, multiple cameras, and camera exposure are discussed in the following sections:  
"Firmware Updates" on page 106  
"Streaming Error" on page 107  
"Ethernet Switch Issues" on page 113  
"Multiple Camera Issues" on page 113  
"Camera Exposure Issues" on page 114  
102 Troubleshooting  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Issues and Functional Problems  
This section covers issues indicated by the GigE server tray icon shows a warning symbol.  
GigE Server Warning Example 1a: IP error with multiple NICs  
The screenshot below shows an IP conflict error due to two (or more) NICs that are all set to LLA mode. In this  
case both NICs are assigned the same IP address preventing communication with any connected Genie.  
When multiple NICs are used, only one can be set to LLA mode. A second NIC connected to Genie must use  
the persistent IP mode or must have a DHCP server on that subnet. The following illustration shows such a  
setup.  
LLA Mode (only 1 NIC)  
NIC 1  
LLA Mode (error)  
NIC 2  
Persistence Mode - OK  
DHCP Options  
DHCP Server  
NIC n  
Software  
DHCP Server  
Hardware  
For more information see "Multiple Camera Issues" on page 113, "Using Genie with Ethernet Switches" on  
page 17, and "IP Configuration Mode Details" on page 77.  
Genie Monochrome Series-GigE Vision Camera  
Troubleshooting 103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
GigE Server Warning Example 1b: IP error with multiple NICs  
As a second example, the screenshot below shows an IP conflict error similar to the example above but the second  
NIC has no camera connected (or only an Ethernet switch).  
The following illustration shows an example of this fault condition. The second NIC has not Genie connected  
ether directly or via a switch.  
LLA Mode (only 1 NIC)  
NIC 1  
LLA Mode (error)  
Ethernet  
Switch  
NIC 2  
Persistence Mode - OK  
The solution again is that the second NIC must use the persistent IP mode or must have a DHCP server on that  
subnet.  
For more information see "Multiple Camera Issues" on page 113, "Using Genie with Ethernet Switches" on  
page 17, and "IP Configuration Mode Details" on page 77.  
104 Troubleshooting  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
GigE Server Warning Example 2: Subnet Mask or IP error  
The screenshot below shows that the Genie device is not accessible. This IP error is an example of the Genie being  
assigned a persistent IP address with an incorrect subnet mask.  
This example error was made using the DALSA Network Configuration tool, where the Genie was set to  
Persistent IP mode with an incorrect subnet mask.  
Once the incorrect setting was applied, the Genie was not accessible to the Network Configuration tool or any  
application.  
The DALSA Network Configuration tool provides a device recovery function to force the Genie back to LLA  
An alternative solution is to change IP address of the NIC to match the camera subnet. This might be preferable  
if a DHCP server is running on this segment (as the Recovery process requires the NIC to be in LLA mode).  
GigE Server Warning Example 3: Filter Driver (CorSnid) Disabled  
The screenshot below shows that the Genie device was found but there is an issue with the filter driver (CorSnid).  
Such problems occur because the filter driver has become disabled or never installed correctly.  
Verify that the Filter driver is enabled in the properties for the NIC used with Genie. The screenshot below  
shows a typical installation.  
Genie Monochrome Series-GigE Vision Camera  
Troubleshooting 105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Information about the CorSnid driver is also available from Network Configuration tool.  
Device Available with Operational Issues  
This section considers issues with cabling, Ethernet switches, multiple cameras, and camera exposure.  
Firmware Updates  
As a general rule any Genie installation must include the firmware update procedure (see "Updating Genie  
Firmware" on page 27). Genie camera firmware that does not match a newer version of installed Genie Framework  
software is likely to have unpredictable behavior. Problems might be:  
Genie is not found by the device discovery process.  
Genie is found by the Sapera GigE Server but an application such as CamExpert does not see the camera.  
Important: New Genie cameras installed in previously deployed systems are fully backward compatible with the  
older vision application. New Genie cameras must not be programmed with older firmware.  
106 Troubleshooting  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power Failure During a Firmware Update–Now What?  
Don't panic! There is far greater chance that the host computer OS is damaged during a power failure than any  
permanent problems with the Genie. When electrical power returns and the host computer system has started, the  
Genie firmware reprogramming sequence is as follows.  
Connect power to the Genie. The Genie processor knows that the operating firmware is corrupt.  
The Genie status LED is slow flashing red. This will continue for about 2 minutes (pre-2007 Genie cameras  
may take up to 5 minutes and has no led status).  
During this period, the Genie is loading embedded write-protected firmware. When the status LED goes blue  
the Genie is initialized with a minimal safe boot firmware.  
The Genie is now operating normally as a network device but will not function as a camera.  
Perform the firmware update procedure (see "Updating Genie Firmware" on page 27) again. The Genie is now  
be ready for use.  
Streaming Error: No Acquisition with a Timeout Message  
A streaming error is typical with a firewall not allowing the filter driver through. As an example, CamExpert will  
run (but start slowly due to initialization timeouts), the Genie is visible in the device pane, but no parameters are  
shown to control the camera.  
If the host computer is using a firewall, either add the GigE Server in the firewall exception list or disable the  
firewall completely on the NIC used only with the Genie. Review the following information on disabling  
Windows Firewall on the NIC used with Genie.  
Run the Sapera log viewer program. A firewall block is identified as a timeout event as shown in the following  
screen capture (the Genie identifier will match the Genie in use).  
Disabling Windows Firewall  
Connecting the Genie camera to a system running a firewall would require careful planning of the camera IP and the  
ports used by the streaming video and messaging. In general, the Genie camera is installed in a private network or  
within a corporate network with an external firewall. In both these cases, the host system that the Genie connects to  
does not need to run a firewall, therefore eliminating installation issues.  
The Network Configuration tool automatically adds the Sapera GigE Server in the list of Exceptions of the  
Windows firewall. Therefore, in most situations, you don’t have to take any special precaution to have the Genie  
run through the firewall.  
The following figure shows how to turn off the Windows XP firewall when the computer is behind a corporate  
network firewall. Run the Windows firewall application from the start menu Start Settings Control Panel ●  
Windows Firewall. If the host computer is running a firewall from a third party, review the program's  
documentation to disable its execution.  
Genie Monochrome Series-GigE Vision Camera  
Troubleshooting 107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Turning Windows Firewall Off  
With a computer that is not behind a corporate firewall an alternative is to disable Windows firewall only for the  
network adapter dedicated for the Genie camera. Such a computer would have two or more network adapters where  
one NIC only connects to the Genie—never the Internet.  
The following figures show an example of the Windows firewall On but disabled for the network adapter used by  
Genie.  
Windows Firewall Off for Genie Only  
108 Troubleshooting  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Test a Genie Using Internal Test Patterns  
The Genie test pattern mode allows quick verification of an installation without the need for correct lighting or lens.  
Troubleshooting physical connection issues or communication problems is made easier knowing that the camera can  
output a known video signal at selectable frame rates. See "Internal Image Test Patterns" on page 62 for information  
on using CamExpert to select internal patterns from Genie.  
Cabling and IP Configuration Issues  
With only two cables connected to Genie, possible cabling issues are limited.  
Power supply problems:  
If the Genie status LED is off, the DC supply power is not connected or faulty. Verify the power supply voltage  
at the Hirose connector. See "12-Pin Hirose Connector Signal Details" on page 90 for pinout information.  
Communication problems:  
Use a shielded cable where the Hirose connector shell electrically connects the Genie chassis to the power  
supply earth ground. This can eliminate trigger issues in a high EMI environment.  
Check that the Ethernet cable is clipped both to the Genie and the NIC or switch on the other end.  
Verify the Ethernet cabling. Poor cables will cause connections to auto-configure at lower speeds.  
Use the Genie Ethernet status LED to confirm a gigabit connection. Note that a gigabit connection may still  
have many packet resends, rendering the connection useless. This condition has been seen with different NIC  
products.  
Use a secured Ethernet cable when the Genie is in a high vibration environment. See "Ruggedized RJ45  
Ethernet Cables" on page 97.  
Check the Ethernet status LEDs on the Genie RJ45 connector. The network speed indicator should show the  
expect connection speed and the activity LED should flash with network messages.  
Verify that the Ethernet cable is CAT5e or CAT6. This is very important with long cable lengths.  
When using very long cables, up to the maximum specified length of 100m for gigabit Ethernet, different NIC  
hardware and EMI conditions can affect the quality of transmission.  
Minimum recommended Ethernet cable length is 3 feet (1 meter).  
Use the Log Viewer tool (see point below) to check on packet resend conditions.  
See "RJ45 LAN Ethernet Connector Details" on page 92 RJ45 LAN Ethernet Connector Details for more  
information on the Ethernet connection status LEDs.  
The Genie camera status LED, when connected and assigned an IP address will light steady blue. See "Camera  
Status LED" on page 93 for details on all camera states indicated by the LED.  
When using a VLAN Ethernet switch, the Genie and controlling computer must be on the same subnet setup on  
that VLAN switch. See "Using Genie with a VLAN Ethernet Switch" on page 18.  
Run the Sapera Log Viewer: Start•Programs•DALSA•Sapera LT•Tools•Log Viewer. Start the Genie  
acquisition program, such as CamExpert. There should not be any "packet resend" messages, else this indicates  
a control or video transmission problem due to poor connections or extremely high EMI environments.  
Streaming Video (grab) Issues  
Streaming video problems range from total loss of image data to occasional loss of random video data packets. The  
following section describes conditions identified by DALSA engineering while working with Genie in various  
computers and setups.  
Genie Monochrome Series-GigE Vision Camera  
Troubleshooting 109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Grab Remains Black  
While using CamExpert to test a Genie installation, there are no obvious installation problems. But when Grab is  
clicked in CamExpert, a grab failure occurs. The grab remains black and an Abort message is displayed.  
Typically this problem occurs when the video stream is blocked by a third-party firewall program. Configure  
the firewall to pass GigE Vision applications.  
Confirm that the problem is the firewall settings and not the Genie sensor by configuring Genie to output its  
internal test pattern (see "Internal Image Test Patterns" on page 62).  
Computers with VPN software installed most likely need to have the VPN driver disabled in the NIC  
properties. This would be required only on the NIC used with the Genie.  
Grab has Random Bad Data or Noise  
The problem is seen as random noise and missing sections of video data from the acquisition. All configuration  
parameters seem correct and the Ethernet cable is secure. The following image shows an example of this type of bad  
acquisition while testing a Genie installation with CamExpert (with the Genie set to generate its internal test  
pattern).  
Following are various examples of this data transmission problem. The solutions vary but commonly involve  
reducing the maximum packet size claimed by the NIC used.  
Grab has Random Bad Data or Noise – Case 1  
This problem has been seen on some computers where the NIC used does not fully support passing the  
maximum jumbo frame possible from the Genie.  
In the NIC configuration, keep the jumbo frame size set to the maximum allowed. See "Increasing Adapter  
Buffers and Jumbo Frames" on page 24.  
Using CamExpert, test for a good acquisition by reducing the Genie packet size used. See "CamExpert GigE  
Vision Parameters" on page 65. Also check for packet resend messages with the Sapera tool "Log Viewer".  
110 Troubleshooting  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Grab has Random Bad Data or Noise – Case 2  
This problem has been seen with network adapters using the Realtek RTL8169 chip and associated low-level  
driver. In this case the NIC reports a false maximum jumbo frame size.  
In the NIC configuration, set the jumbo frame size set to less than the maximum allowed. In this example the  
NIC reports supporting a maximum jumbo frame size of 8384 but good acquisitions are possible only when the  
size is reduced to 7k. See "Increasing Adapter Buffers and Jumbo Frames" on page 24. and the image below.  
Using CamExpert, test for a good acquisition by reducing the Genie packet size used. Set the value to the new  
reduced size set in the NIC configuration. See "CamExpert GigE Vision Parameters" on page 65.  
Verify there are no packet resend messages with the Sapera tool "Log Viewer".  
Grab has Random Bad Data or Noise – Case 3  
This problem has also been seen with network adapters that do not support jumbo frames but still report a false  
maximum packet frame size.  
When using CamExpert, if the Network Configuration Mode is left as Automatic (default), CamExpert uses the  
value the NIC reports as its maximum. This maximum value is actually not supported.  
Test for a good acquisition by reducing the Genie packet size used. Set the value to a starting value of 1500 to  
verify acquisition before trying a higher value. See "CamExpert GigE Vision Parameters" on page 65.  
Laptop Computer Networking Issues  
Laptop computers with built in GigE network adapters may still not be able to stream full frame rates from Genie.  
Laptops with gigabit Ethernet PCMCIA boards may not be able to stream video at all unless network parameters are  
modified. Thorough testing is required with any laptop computer.  
Streaming video problems may change depending on the computer chipset and NIC combinations. Laptops running  
on battery power may exhibit more bandwidth issues due to the inherent power saving characteristics of laptops.  
This section describes a few configuration items to modify for best performance. Verify the Genie at the frame rates  
required or to determine the maximum frame rate possible with the laptop used.  
Genie Monochrome Series-GigE Vision Camera  
Troubleshooting 111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configuration Recommendations with Laptops  
In the NIC configuration, keep the jumbo frame size set to the maximum allowed. See "Increasing Adapter  
Buffers and Jumbo Frames" on page 24.  
If VPN software is installed, most likely the VPN driver must be disabled in the NIC properties (open via  
Control Panel). This would be required only on the NIC used with the Genie.  
Run the Sapera Log Viewer: Start•Programs•DALSA•Sapera LT•Tools•Log Viewer. Start the Genie  
acquisition program, such as CamExpert. There should not be any "packet resend" messages, else this indicates  
problem due to poor connections or extremely high EMI conditions.  
Packet resends might also be eliminated by adjusting the GigE parameter Inter-Packet Delay. Using CamExpert  
(see "CamExpert GigE Vision Parameters" on page 65), increase the inter-packet delay value from 0 to  
0.000050 (50µs) and test again.  
Problems when Changing the Laptop NIC  
If a laptop has had a Genie installed on it and a new NIC is later installed on the laptop, a Genie connected to the  
new NIC will not be found. A quick solution is to deselect/reselect the CorSnid driver on that NIC as follows.  
Open the NIC properties (the one connected to Genie) via Control Panel.  
CorSnid Driver Selection  
Deselect the CorSnid driver and click the OK button.  
Open the NIC properties again and reselect the CorSnid driver.  
The Genie will now be found via the automatic device discovery process. This will take a few seconds.  
112 Troubleshooting  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Problems with Disconnecting NICs  
Genie cameras installed in environments with physical motion, vibrations, or high EMI may be disconnected by the  
NIC. The following items need to be reviewed to solve the problem.  
Motion or vibrations may cause data loss because the Ethernet cable connection is not secure. Use a locking  
Ethernet cable (see "Ruggedized RJ45 Ethernet Cables" on page 97).  
High EMI may cause the NIC to drop data or to disconnect and reconnect at a lower data rate. Such situations  
do not have simple solutions and may require an expert consultant.  
Some NIC products may not tolerate any data disruptions. Any condition causing the NIC to drop the  
connection may make it unrecoverable. Communication with the Genie can not be reestablished without power  
cycling. In this case, trying a variety of NIC products is suggested.  
Ethernet Switch Issues  
An Ethernet switch usually works transparently and presents no problems. Review the following list when  
troubleshooting switch issues.  
Is the Ethernet switch powered on.  
Are all ports used configured as active; not disabled.  
Are all ports running at gigabit speeds–not low speed (i.e. not 10 or 100 Mbps).  
Is the switch configured to use Jumbo Frames.  
Verify the Ethernet cabling. Poor cables will cause connections to auto-configure at lower speeds.  
When using a VLAN Ethernet switch, confirm that the Genie and controlling computer are on the same  
VLAN group setup on that switch.  
When using a chain of switches, ensure that inter-switch connection speeds are the same (1000 Mbps).  
Multiple Camera Issues  
When using multiple cameras with a computer with multiple NIC ports, confirm each Genie has been assigned  
an IP address by checking the GigE server (see "Sapera GigE Server Details" on page 83).  
Do not use multiple NIC port configured in LLA. In this case use a DHCP server or persistent IP.  
When using multiple cameras connected to an VLAN Ethernet switch, confirm that all cameras are on the same  
subnet setup on that switch. See "Using Genie with a VLAN Ethernet Switch" on page 18.  
Genie Monochrome Series-GigE Vision Camera  
Troubleshooting 113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Camera Exposure Issues  
No camera exposure when expected.  
Verify by using the camera in free-running mode. Do not use external trigger mode when testing a camera  
setup.  
If using free-running mode, verify that the exposure period is set to the maximum possible for the set frame  
rate.  
Load factory default from the Power-up Configuration in CamExpert. This will reset the camera to its  
nominal acquisition rate.  
Camera is functional but frame rate is lower than expected.  
Verify Ethernet link speed. If the LAN connection is limited to 100 Mbps, the monochrome Genie frame  
rate maximum will be around 30 fps for a 640x480 exposure. Higher resolution Genie models would have  
even lower frame rates without a Gigabit Ethernet connection.  
If using an external trigger, verify the trigger source rate and Genie parameters such as trigger to exposure  
delay.  
Verify the exposure mode type is Synchronous, not Reset mode. (See "Synchronization Timing" on page  
46).  
Camera is functional, frame rate is as expected, but image is black.  
Verify that the lens iris is open.  
Aim the Genie at a bright light source.  
Check that the programmed exposure duration is not too short or set it to maximum. See "Exposure  
Controls" on page 43.  
Using CamExpert set the Genie to output its internal pattern generator. This step is typically done for any  
camera installation to quickly verify the Genie and its software package.  
114 Troubleshooting  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Verifying Network Parameters  
DALSA provides the Network Configuration tool to verify and configure network devices and the Genie network  
parameters. See section "Network Configuration Tool" on page 79 if there were any problems with the automatic  
Genie software installation.  
VPN Driver Interference  
VPN (virtual private network) software using a driver component called "Deterministic Network Enhancement" has  
been identified as interfering with the Genie operation when using Framework versions previous to 1.20. At the  
time to solution was to disable this VPN driver by deselecting the component from the NIC properties (see  
following figure).  
With Genie Framework version 1.20 or later, there is no need to disable this VPN component.  
Genie Monochrome Series-GigE Vision Camera  
Troubleshooting 115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
116 Troubleshooting  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DALSA Contact Information  
Genie Sales Information  
Visit our web site:  
Email:  
International/Canada  
DALSA — Montreal office  
7075 Place Robert-Joncas  
Suite #142  
St. Laurent, Quebec, Canada  
H4M 2Z2  
Tel:  
Fax:  
(514) 333-1301  
(514) 333-1388  
USA  
DALSA  
700 Technology Park Drive  
Billerica, Ma. 01821  
Tel:  
Fax:  
(978) 670-2000  
(978) 670-2010  
Genie Monochrome Series-GigE Vision Camera  
DALSA Contact Information 117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Genie Technical Support  
Any support question or request can be submitted via our web site:  
Technical support form via our web page:  
Support requests for imaging product installations,  
Support requests for imaging applications  
Product literature and driver updates  
118 DALSA Contact Information  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Glossary of Terms  
ARP  
Address Resolution Protocol provides a way to retrieve the MAC address associated to an IP address.  
Bandwidth  
Describes the measure of data transfer capacity.  
CAT5e Ethernet cable  
Category 5e was designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).  
CAT6 Ethernet cable  
Same as Category 5e, except that it is made to a higher standard. Supports transmission speeds greater than  
Gigabit Ethernet with less signal attenuation over a given length of cable.  
CCD – Charge-Coupled Device  
A type of image sensor converting light into electrical charges.  
Contiguous Memory  
A block of physical memory occupying consecutive addresses.  
DHCP (Dynamic Host Configuration Protocol)  
Protocol which provides a mechanism for allocating IP addresses dynamically by a DHCP server on a  
network. Typically dedicated DHCP servers are a component of corporate networks. Used for managed  
networks.  
Driver  
Also called a device driver, a program routine that links a peripheral device to the operating system. a  
device driver is required for its frame grabber capabilities.  
DSNU  
Dark Signal Non-Uniformity (equivalent to FPN).  
Ethernet Switch  
A network device performing bridging at full wire-speed based on MAC addresses. Packet collisions are  
eliminated when using a full duplex switch. An Ethernet Switch operates at Layer 2 of the seven-layer OSI  
model.  
FPN  
Fixed Pattern Noise (equivalent to DSNU). FPN is the peak to peak difference between the minimum and  
maximum measured values for all active valid pixels sensor in darkness. Fixed Pattern Noise does not  
include a Random Noise component.  
Frame  
One complete image data set or its equivalent storage space.  
Frame buffer  
An area of memory used to hold a frame of image data. A frame buffer may exist on the acquisition  
hardware or be allocated by the acquisition hardware device driver in host system memory.  
GigE Vision specification  
Specification of the Automated Imaging Association (AIA, www.machinevisiononline.org). Defines the  
communication interface protocol used by any GigE Vision device.  
Genie Monochrome Series-GigE Vision Camera  
Glossary of Terms 119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
GenICam specification  
Specification of the European Machine Vision Association (EMVA, www.emva.org). Defines the  
capabilities of any GigE Vision device.  
Grab  
Acquiring an image frame.  
Grayscale  
In image processing, the range of available brightness levels, displayed in shades of gray. In an 8-bit  
system, the gray scale contains values from 0 to 255. A 10-bit system has a range of 0-1023.  
GVCP – GigE Vision Control Protocol  
One of the core protocols of the GigE Vision specification used to control camera. GVCP uses UDP port  
3956 on the camera.  
GVSP – GigE Vision Stream Protocol  
One of the core protocols of the GigE Vision specification used to stream images.  
Host  
Refers to the computer system that supports the installed frame grabber.  
IP – Internet Protocol  
The Internet Protocol is the method by which data is sent from one computer to another on a network or  
across the Internet. Each device must have an IP address to identify that device on the network or on the  
Internet.  
LLA  
Link-Local Address is a protocol providing a scheme for devices to automatically assign themselves an IP  
address and check for IP conflict. Used in unmanaged networks.  
NIC  
Network Interface Card/Controller. For the Genie products the NIC must be a Gigabit Ethernet interface to  
provide sufficient bandwidth.  
Pixel  
A contraction of "picture element". The number of pixels describes the number of digital samples taken of  
the analog video signal. The number of pixels per video line by the number of active video lines describes  
the acquisition image resolution. The binary size of each pixel (e.g., 8-bits, 16-bits, 24-bits) defines the  
number of gray levels or colors possible for each pixel.  
PRNU  
Photo-Response Non-Uniformity. For a given even illumination the difference between the minimum and  
maximum measured pixel values is the PRNU.  
Progressive Scan Camera  
The progressive scan format outputs data from the camera (the signal) in sequential order as it is scanned.  
The scan format produces a full frame of video in a continuous stream, rather than half the image per  
output sequence in standard interlaced cameras.  
Random Noise  
Random noise is defined as the difference in peak to peak value for any single pixel repetitively sampled,  
with the sensor in darkness. For digital cameras the measurement is based on at least 512 samples from any  
pixel.  
Router  
A Router device forwards packets across networks. It operates at Layer 3 of the seven-layer OSI model.  
Note that broadcast packets (such as GigE Vision Device Discovery message) do not cross routers.  
120 Glossary of Terms  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAT  
Saturation Output Amplitude. SAT is the average maximum output level for a specified light input.  
Scatter Gather  
Host system memory allocated for frame buffers is virtually contiguous but physically scattered throughout  
all available memory.  
SNR  
Signal to Noise Ratio. SNR measures the ratio between random noise and an arbitrary reference signal on  
the transmission path or within a device.  
Subnet  
The subnet is identified by performing the logical AND of the IP address with its subnet mask.  
TCP  
Connection-oriented transport protocol providing robustness and reliability. Used by many Internet  
application, such as HTML.  
Trigger  
A mechanism that initiates an action when an event occurs such as synchronizing an image acquisition to  
an external event. A trigger generally causes a program routine to be executed such as the resetting of  
camera exposure and/or the firing of a strobe light.  
UDP  
User Datagram Protocol is a connectionless transport protocol providing no guaranty of delivery or  
reliability. GigE Vision Control Protocol and GigE Vision Stream Protocol are based on UDP.  
VLAN  
A Virtual Local Area Network is a flexible arrangement where computers connected via a VLAN Ethernet  
switch are not necessarily on the same LAN broadcast domain. Refer to the VLAN Ethernet switch  
documentation for implementation and configuration details.  
VPN  
A virtual private network is a private data network that makes use of the public telecommunication  
infrastructure, maintaining privacy through the use of a tunneling protocol and security procedures. The  
idea of the VPN is to give the company the same capabilities at much lower cost by using the shared public  
infrastructure rather than a private one. (source: www.netunlimited.com/glossary.html )  
Genie Monochrome Series-GigE Vision Camera  
Glossary of Terms 121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
122 Glossary of Terms  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
effective focal length, 94  
embedded processing, 56  
Ethernet cable type, 92  
Ethernet link speed, 114  
Ethernet switch, 17  
Index  
Ethernet switch issues, 113  
event modes, 51  
event notification, 92  
events, 63  
exposure duration, 43  
exposure period, 114  
Exposure time granularity, 46  
external trigger, 114  
1
12-pin male Hirose connector, 90  
8
8/10-bit LUT, 56  
F
factory default state, 67  
fastest frame rates, 43  
feature availability, 72  
feature interdependence, 72  
feature type, 68  
A
Acquisition events, 63  
administrator, 19  
AUTORUN, 19, 20  
fiber-optic light sources, 93  
Firewall exception list, 80  
firewall exceptions, 18  
firewall issues, 107  
firmware update, 19, 27  
flat field correction, 58  
focal point, 94  
B
back focal length, 94  
Binning, 41  
binning modes, 41  
frame rate, 41  
Frame Trigger modes, 42  
free running mode, 43  
C
cable mating connector, 90  
camera configuration, 32  
camera interfacing tool, 85  
camera parameters, 67  
camera state LED, 21  
camera status, 93  
CamExpert parameters, 29  
CCD Technology Primer, 93  
command jitter, 42  
G
gain and black level, 36  
gamma adjustments, 56  
GenICam compliant, 18  
GenICam Specification, 7, 9, 15, 18  
Genie connectors, 21  
Genie flash memory, 79  
Genie identifier, 29  
Genie parameters, 68  
Communication problems, 109  
Components Express Inc., 97  
controlling event, 42  
Genie rear view, 21  
current system information, 80  
Genie software package, 19  
Gigabit NIC, 17  
GigE server, 20  
D
GigE Server, 20, 26, 83  
GigE Server Status, 83  
DALSA Network tool, 77  
debounce circuit, 49  
device discovery, 29  
Device reset complete, 28  
DHCP, 23  
DHCP server, 77, 78  
DHCP/LLA, 79  
diagnostic LED, 19  
dropping packets, 66  
Dust problems, 95  
GigE server tray icon, 20, 23, 101, 102, 103  
GigE Vision compliant, 23  
GigE Vision Control Protocol, 83  
GigE Vision Parameters, 65  
GigE Vision Specification, 6, 9  
grab Abort message, 110  
grab failure, 110  
H
E
halogen light sources, 93  
heartbeat timeout, 66  
Edge Pre-select, 44  
Genie Monochrome Series-GigE Vision Camera  
Index 123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
high EMI, 109, 112  
Hirose HR10A-10P-12S, 21  
histogram tool, 58  
N
network configuration, 26  
horizontal and vertical binning, 41  
horizontal crop, 38  
hot mirror, 94  
Network Configuration Mode, 66  
network configuration tool, 79  
Network Configurations, 17  
Network Imaging driver, 20  
Network Imaging Driver, 82  
network optimizations, 65  
network status, 21, 92  
HTML help, 7  
I
NIC host buffers, 24  
NIC receive descriptor, 24  
I/O signal specification, 90  
image buffer, 40  
image cropping, 40  
image exposures, 42  
image processing, 7  
O
incoming image packets, 24  
industrial RJ-45, 97  
infrared filters, 94  
internal pattern, 114  
inter-packet delay, 66  
invalid trigger, 53  
object distance, 94  
operational status, 22, 93  
optimize network, 65  
opto-coupled inputs, 49  
opto-coupled outputs, 51  
opto-coupler, 92  
ionized air blower, 95  
IP configuration, 21  
output static state, 51  
Over voltage, 91  
IP configuration modes, 77  
IP configuration protocol, 21, 23  
P
packet resend, 110, 111  
packet resend conditions, 109  
packet resends, 66  
J
jumbo frames, 110, 111  
jumbo packets, 66  
packet size, 66  
PDF, 7  
persistent IP, 79  
Persistent IP, 23  
L
persistent IP address, 82  
power failure during update, 107  
procedures for handling, 95  
protection circuit, 91  
pulse duration, 52  
laptop optimizations, 65  
laptops, 66  
launch.exe, 19, 20  
LED color, 93  
LED light sources, 93  
LED states, 22  
Pulse Width Control, 45  
light source aging, 94  
limited or no connectivity, 77  
line rate, 10, 11, 12, 13, 14  
Link-Local Address, 23  
Log Viewer tool, 109  
long cable lengths, 109  
low frame rates, 114  
low-light sensitivity, 41  
LUT examples, 88  
R
random noise, 110  
real time processing, 56  
resolution, 10, 11, 12, 13, 14  
Responsivity, 93  
reverse voltage, 91  
RJ45 Ethernet, 90  
routers, 77  
LUT table, 56  
M
S
MAC address, 30  
Sapera block diagram, 15  
Sapera CD-ROM, 19, 20  
Sapera LT Development Library, 19  
Sapera LT User’s manual, 19  
Sapera Run-time, 18  
managed network, 78  
maximum frame rate, 46  
Multiple Genie cameras, 17  
multiple subnets, 18  
secured Ethernet cable, 109  
sensor controls, 34  
sensor integration period, 43  
124 Index  
Genie Monochrome Series-GigE Vision Camera  
Download from Www.Somanuals.com. All Manuals Search And Download.  
sensor specification, 9  
sensor specifications, 8  
sensor synchronization, 46  
signal debounce circuit, 49  
software triggers, 42  
spatial resolution, 41  
Static electricity, 17  
static IP address, 78  
status LED sequence, 23  
strobe light, 51  
subnet, 20, 81, 109  
synchronization timing, 43  
T
test pattern, 110  
test pattern generator, 62  
test patterns, 29  
threshold processes, 56  
Transfer events, 63  
U
V
unmanaged networks, 77  
User Name, 30  
user state, 67  
user-defined name, 30  
vertical and horizontal cropping, 38  
vertical cropping, 37  
video stream problems, 110  
visible light, 9  
VLAN Ethernet switch, 18  
VLAN group, 18  
W
workstation, 19  
X
XML device file, 15  
Genie Monochrome Series-GigE Vision Camera  
Index 125  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ecom Instruments Cell Phone Ex CDMA 02 User Manual
Eton MP3 Player FR405 User Manual
Euro Pro Vacuum Cleaner UV209H User Manual
FieldServer Computer Drive FS 8700 01 User Manual
Finisar Network Card FTLF1217P2XTL User Manual
Focal Portable Speaker SM8 User Manual
Fujitsu Car Video System fd 1100mt User Manual
GE Conference Phone Feb 74 User Manual
GE Refrigerator 2 Cubic Foot 3 Cubic Foot 4 Cubic Foot 6 Cubic Foot User Manual
Global Machinery Company Paper Shredder SHS2400 User Manual