Country Flame Indoor Fireplace INGLS 24 N User Manual

COUNTRY FLAME TECHNOLOGIES  
INSTALLLATION, OPERATION, AND MAINTENANCE MANUAL  
INGLENOOK FIREPLACE GAS LOG SET  
MODEL INGLS 24-N OR INGLS 24-P  
NATURAL GAS OR PROPANE CONVERSIOIN KIT  
USA & CANADA TEST:  
TESTED BY:  
Harmonized ANSI Z21.60-2003  
CGA 2.26-MO3 & CAN/CGA-21.7.M91  
WARNOCK HERSEY  
WARNING: If the directions contained in this manual are not followed  
exactly, a fire or explosion may result causing property damage, personal injury  
or loss of life.  
IF YOU SMELL GAS  
FOR YOUR SAFETY  
Do not light any appliance.  
Do not touch electrical switches; do not use the phone in your  
building.  
Immediately call the gas company from a neighbor’s phone.  
Follow gas company instructions.  
Call the Fire Department if Gas Company doesn’t answer.  
FOR YOUR SAFETY  
Do not store or use gasoline or any flammables (vapors or liquids) in the vicinity of  
this or any other appliance.  
Country Flame Technologies  
A Division of American Products, LLC  
900 George Street  
Marshfield, MO 65706  
417-859-0990  
Installation and repair must be performed by a qualified service person or gas supplier.  
417-859-0192  
© 2004  
COUNTRY FLAME  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
NOVA mV SET-UP GUIDE.........................................................................................................31  
SAFETY LABEL...................................................................................................................... 32  
REPLACEMENT PARTS – INGLS 24N or INGLS 24P.............................................................33  
LIMITED 10 YEAR WARRANTY..............................................................................................34  
Version 1.0b  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
THANK YOU and CONGRATULATIONS on the purchase of a new Inglenook gas log kit. The Inglenook  
fireplace is a solid fuel (wood only) burning appliance; however, many Country Flame customers requested  
the capability to convert their Inglenook fireplace to a natural gas or a propane gas log set instead of being  
required to use solid fuel. Inglenook owners are already part of the thousands of members referred to as  
Country Flame Family. To ensure continued product satisfaction, Country Flame designed, developed and  
manufactured the new Inglenook gas log set for Inglenook owners that want to convert their product from  
wood to gas. This Country Flame gas log set is the only product certified for use and can only be used in the  
Inglenook solid fuel fireplace. Using this certified Country Flame gas log set in the Inglenook fireplace  
protects the environment while obtaining maximum value from the purchase.  
Each employee at Country Flame pledges to ensure every one of our customers has our continuing  
commitment of product support. Country Flame dedicates its product support to ensuring a customer obtains  
the greatest level of satisfaction from the proper use of our products. Thank you for continuing to select  
Country Flame to satisfy your hearth needs. We look forward to hearing from you, as this product becomes  
part of your home heating solution.  
Country Flame wrote this manual to assure proper installation, proper maintenance, and correct operation of a  
gas log set in an Inglenook Solid Fuel (wood) fireplace. Once converted, the Inglenook Fireplace CANNOT  
be used to burn solid wood fuel unless it is re-converted back to solid fuel operation. In the event of any  
questions or confusion on the installation or operation of the Inglenook, contact Country Flame or a certified  
professional before undertaking the installation or operation of this appliance.  
Country Flame wishes you a lifetime of warmth and happiness.  
Version 1.0b  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
-
The Inglenook gas log kit is designed to be installed only in an Inglenook solid-fuel burning fireplace  
that has a working flue constructed of noncombustible materials.  
-
Maintain a minimum permanent free flue opening of 50.2 square inches provided by the Inglenook  
fireplace chimney and chimney damper system to vent flue gasses. Maintain this permanent free flue  
opening by keeping the damper in the fully open position during gas log use. See FIGURE 2.  
Solid fuels will not be burnt in the Inglenook fireplace while the Inglenook gas log set is installed.  
The Inglenook fireplace damper is to remain the open position, see FIGURE 2, at all times during the  
use of the Inglenook gas log set. Attach a damper clamp as shown in this manual.  
A fireplace screen must be in place at all times when operating the Inglenook gas logs. The  
Inglenook combustion air vent is to be installed and open during gas log burning.  
The Inglenook and the Inglenook gas valve is to be disconnected from the gas supply line during any  
gas supply system testing where test pressures exceed ½ pounds per square inch gauge (psig) (3.5  
kPa).  
-
-
-
-
-
Do not use the Inglenook gas log system if any part of the system has been under water. Immediately  
contact a certified service technician to inspect the appliance. Replace any part(s) of the control  
system or the gas valve that has been under water.  
-
-
-
Do not store or use gasoline or other flammables near this appliance.  
Do not place clothing or flammable material on or near this appliance.  
Due to high operating temperatures, this appliance should be located out of high traffic areas and  
away from furniture and draperies.  
-
Children and adults should be alerted to the hazards of high surface temperatures. Maintain safe  
clearances (stay away) to avoid burns or clothing ignition.  
-
-
Always supervise young children playing in the same room as this operating appliance.  
Any safety screen, guard or other parts removed for servicing this appliance must be replaced prior to  
operation.  
-
-
A CERTIFIED GAS TECHNICIAN SHOULD PERFORM INSTALLATION AND REPAIR.  
ONCE INSTALLED, AN ANNUAL INSPECTION NEEDS TO BE PERFORMED BY A  
CERTIFIED GAS PROFESSIONAL.  
The interior of a gas stove is subject to surface rust due to moisture in the combustion air as well as  
condensation created during the initial warm up and firing of the gas appliance. At a minimum,  
annually clean and repaint the interior surfaces of the firebox to prevent deterioration. More frequent  
cleaning may be required due to carpet lint, bedding material, dust, etc. being drawn into the  
appliance. It is imperative that this appliance’s control compartment, burners, circulating air system  
is kept clean.  
-
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR  
MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS  
MANUAL FOR ASSISTANCE OR FOR ADDITIONAL INFORMATION CONSULT A  
QUALIFIED INSTALLER, SERVICE AGENCY, OR GAS SUPPLIER.  
-
-
-
ALWAYS use high temperature rated silicone or sealing compound at 600OF (316OC) or higher.  
The Inglenook gas logs are designed to operate with the doors fully open or fully closed.  
WARNING: AN INGLENOOK GAS LOG KIT IS DESIGNED FOR A VENTED INGLENOOK  
FIREPLACE WITH AN 8 INCH DIAMETER CHIMNEY PIPE A MINIMUM OF 8 FEET TALL  
TO A MAXIMUM OF 50 FEET TALL. REFER TO PAGE 32 AND 33 OF THE INGLENOOK  
OWNER’S MANUAL FOR PROPER CHIMNEY INSTALLATION.  
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE  
Version 1.0b  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION PREPARATION  
IMPORTANT NOTE: Read and comprehend all instructions in this manual before beginning installation.  
Failure to follow these installation instructions may result in a fire hazard, may result in personal injury,  
voids the warranty, and may affect a homeowner’s insurance policy.  
CLEANING  
The Inglenook fireplace requires advanced preparation before installation of a gas log set is completed. The  
amount of preparation time will depend greatly on whether the Inglenook fireplace has been in use (and for  
how long) or whether this is a new installation. If the Inglenook has been in use, it will necessary to  
contract with a professional cleaning service, such as a chimney sweep. Professional cleaning will be  
required both of the Inglenook’s firebox and the chimney system. Once cleaning is complete, perform a  
system check. This system check should ensure the damper is operating freely and properly and that the  
combustion air vent has no blockage allowing free airflow into the combustion chamber.  
NEW INSTALLATION  
For first time Inglenook fireplace installations, complete ALL installation instructions contained in the  
installation, operation, and maintenance manual that was provided with the Inglenook fireplace before  
beginning installation of the Inglenook gas log set. Failure to adhere to all installation requirements for an  
Inglenook solid fuel fireplace can create installation or operational problems when converting or operating  
the Inglenook gas log system. Contact a local authorized dealer or Country Flame to resolve any confusion  
or issues associated with installation. To maintain a valid Country Flame warranty, the use of a certified  
installer is required.  
Once installation of the Inglenook solid fuel fireplace is complete, the installer can begin installation of the  
Inglenook gas log kit. The following pages take the installer through systematic requirements of this gas  
log installation procedure. In the event there is any confusion or questions, please contact a local authorized  
dealer or Country Flame direct.  
Version 1.0b  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
INGLENOOK PARTS REMOVAL  
Once cleaning or installation of the Inglenook solid fuel fireplace is complete, it is time to remove some  
parts that will not be required for gas operation. FIGURE 1 identifies each of these parts and TABLE 1 lists  
each of these parts along with the Country Flame Part Number. Use TABLE 1 as a check sheet when  
removing these parts. Once removed, the wood burning parts need to be properly packed and stored away  
for potential future use. The homeowner should ensure proper storage of the Inglenook solid fuel parts.  
Future conversion of the Inglenook gas log system back to a solid wood fuel system will require the use of  
these parts. If the parts are lost, damaged, or worn, contact Country Flame or an authorized dealer to obtain  
new parts before attempting wood burning operations in the Inglenook fireplace again.  
FIGURE 1: INGLENOOK SOLID FUEL PARTS REMOVAL  
TABLE 1 should be used as a checklist to ensure all solid (wood burning) fuel parts are removed. Once  
removed, these parts should be stored for potential future conversion from gas logs back to solid wood  
burning fuel.  
FIGURE 1 ITEM  
PART DESCRIPTON  
Log Retainer  
PART NUMBER REMOVED  
(1)  
(1)  
(1)  
(2)  
(2)  
(2)  
(3)  
(4)  
(4)  
(4)  
(4)  
(5)  
(5)  
(6)  
(6)  
(7)  
IN-201  
PP-1225  
PP-1225  
IN-54  
PP-766  
PP-766  
IN-47  
PP-868  
IN-202  
IN-203  
IN-204  
IN-93  
¼ by 20 by ½ Security Bolt  
¼ by 20 by ½ Security Bolt  
Starter Air Intake Assembly  
¼ by 20 by ½ Bolt HHCS  
¼ by 20 by ½ Bolt HHCS  
Ash Grate  
Bottom Fire Brick #X1, 4 each  
Bottom Fire Brick #X2, 2 each  
Bottom Fire Brick #X3, 2 each  
Bottom Fire Brick #X4, 2 each  
Ash Pan Box  
Ash Pan Handle  
PP-1192  
IN-72  
PP-159  
disposable  
Ash Pan Compartment Side Plate  
#8 by 32 by 3/8 TEK SMS, 4 each  
Gas Line Knock Out (left side)  
TABLE 1:  
INGLENOOK SOLID FUEL PARTS REMOVAL  
Version 1.0b  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION, GAS LINE  
Installation of the Inglenook fireplace and the Inglenook gas log kit must conform to National Standards,  
NFPA 54 (natural gas) or NFPA 58 (propane). The installation of gas line and leak testing must conform to  
the National Fuel Gas Code ANSI Z223.1 (United States) and CAN/CGA B-149 (Canada) Installation Code  
and all local codes and gas supplier restrictions. The Inglenook fireplace has been tested and approved for  
installation using a (7/8" O.D. / 1/2" I.D.) Model #1650 N Dormont Flex Connector supplied with the unit.  
A licensed plumber will be required to install a gas line and a supply cut-off valve to the Inglenook  
fireplace. Purge air from the gas supply line before connection is made to the Inglenook fireplace. The  
shut-off connection between the gas line and the Inglenook gas logs will be installed similar to that shown  
in FIGURE 2. Do not install gas supply lines in chimneys, gas vents, dumb waiters, elevator shafts, clothes  
chutes, or other air ducts. Gas piping should be sloped ¼” for every 12 feet of horizontal run. The slope  
will run from the gas meter down to the Inglenook. Horizontal runs of gas piping require mechanical  
support every 10 feet by suitable gas pipe hangars or straps. Install drip leg traps where condensate might  
accumulate in the gas supply line. Verify local code requirements for sediment traps. Traps collect  
moisture and sediment that might otherwise block the Inglenook gas log orifices or valves. Blockages can  
prevent the gas log system from operating properly. Depending on the length of gas line installed from the  
gas company meter to the Inglenook gas control valve, different size piping is required. Check with the  
local gas company for requirements but NEVER use plastic or galvanized pipe. Always follow the flow  
direction marked on all gas line connectors. Once installation of the gas line is complete, the Inglenook  
fireplace damper setting should remain in the fully open position as shown in FIGURE 2.  
OPEN  
CLOSED  
GAS LOG  
GAS SUPPLY  
P
ILOT  
AD  
J
ON  
OFF  
IN  
OUT  
GAS LINE  
CUT-OFF  
SIT 820 NOVA mV GAS  
CONTROL VALVE  
LOWER GRILL  
SHOWN OPEN  
FIGURE 2: INGLENOOK GAS LINE INSTALLATION  
PRESSURE TESTING  
The Inglenook and its control valve are to be isolated from the gas supply piping system by closing its  
individual cut-off valve during any pressure testing of the gas supply piping system at test pressures equal  
to or less than ½ psig (3.5 kPa). If pressures above ½ psig (3.5 kPa) are present, the Inglenook and its gas  
valve must be disconnected from the gas supply piping during any pressure testing.  
Version 1.0b  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SIT 820 NOVA mV GAS CONTROL VALVE  
The SIT 820 NOVA mV gas control value is part of the drop in assembly provided with the Inglenook gas  
log kit. This unit sits in the bottom of the Inglenook fireplace with the SIT 820 extending through the ash  
grate opening. The SIT 820 NOVA mV gas control valve, when properly located will be visible through  
the opening in the ash pan housing. Remember, the grate and ash pan were removed in previous steps parts.  
The SIT 820 control valve is connected to the gas supply cut-off valve. FIGURE 3 shows the valve with an  
explanation of its features as follows:  
1. The left knob controls the ON/PILOT/OFF functions.  
2. The right knob controls the manifold pressure to the burners and is labeled HI/LO.  
3. There is an adjust screw for the pilot flame that should only be adjusted by a certified technician.  
4. The SIT 820 has an input pressure test point labeled IN.  
5. The SIT 820 has an output pressure test point labeled OUT.  
To use either of the pressure test points to measure pressure requires test equipment and knowledge  
required by a certified service technician. Improperly adjusting the pilot adjust or the manifold pressure can  
cause damage to the SIT 820 control valve and should only be accomplished by a certified professional.  
For lighting instructions, refer to the section on first fire in this manual or on the units control panel.  
PILOT  
ADJ  
ON  
OFF  
IN  
OUT  
FIGURE 3: SIT 820 mV NOVA GAS VALVE  
NOTE: TP stands for thermopile, TH for thermostat, and TP TH for thermopile and thermostat. See FIGURE 28.  
INGLENOOK GAS LOG KIT  
All the Inglenook fireplace solid fuel parts should now be removed and properly stored. The gas log kit is  
unpacked and ready for installation; however, before starting the installation, the installer should answer  
two important questions. These two questions are called FACTOR A and FACTOR B and are defined as  
follows:  
INSTALLATION FACTOR A:  
Factor A defines the type of gas log fuel that will be used with a specific installation. The homeowner and  
installer must verify that the expected fuel usage and the type of fuel the gas log kit is designed to use are  
one in the same. Correct any discrepancy between the gas log kit’s fuel type and the fuel being used.  
WARNING: Do not use a Country Flame gas log kit with the wrong fuel. Improper fuel use is dangerous  
to facilities and occupants and immediately voids Country Flame’s product warranty. Consult a certified  
installer or authorized dealer.  
INSTALLATION FACTOR B:  
Factor B requires an inventory of the gas log kit to be completed. This inventory will ensure all kit  
components are present and not damaged. Contact Country Flame or an authorized dealer to resolve any  
Version 1.0b  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
discrepancy or to obtain necessary parts to replace any missing or damaged components. TABLE 2  
provides a gas log kit part’s list for both natural gas and propane kits. Use the appropriate version of  
TABLE 2 as a check sheet while verifying the presence and condition of each kit part. Again, contact  
Country Flame or an authorized dealer to resolve any issues before converting the Inglenook gas log set to a  
different fuel.  
LIQUID PROPANE CONVERSION KIT  
ITEM  
QTY  
PART NUMBER  
ITEM DESCRIPTION  
Regulator  
Pilot  
Front Spud Orifice  
Rear Spud Orifice  
Conversion Label  
Instructions  
1
1
1
1
1
1
SIT 820 NOVA mV Gas Valve  
#51 DMS Pilot Injector Orifice  
#31 DMS NG Front Orifice Spud  
#43 DMS NG Rear Orifice Spud  
Conversion LP to NG  
GC-3905-01  
BV-4613  
IN-6513  
IN-6514  
IN-6521  
Conversion Kit Instructions  
IN-6523  
TABLE 2a: IN-6504 CONVERSION KIT (to natural gas)  
NATURAL GAS CONVERSION KIT  
ITEM  
Regulator  
QTY  
PART NUMBER  
ITEM DESCRIPTION  
1
SIT 820 NOVA mV Gas Valve  
#35 DMS Pilot Injector Orifice  
#48 DMS LP Front Orifice Spud  
#55 DMS LP Rear Orifice Spud  
Conversion NG to LP  
GC-3906-01  
BV-4614  
IN-6515  
IN-6516  
IN-6522  
Pilot  
1
1
1
1
1
Front Spud Orifice  
Rear Spud Orifice  
Conversion Label  
Instructions  
Conversion Kit Instructions  
IN-6524  
TABLE 2b: IN-6503 CONVERSION KIT (to propane)  
It should be noted that conversion from one type of fuel to another type of fuel requires the adjustment of  
both the front and rear burner air shutters. Refer to the specifications in this manual and verify local codes  
and other site-specific conditions to ensure proper setting of all parameters involved in the fuel conversion  
process.  
ALTITUDE LIMITATIONS  
In the United States, the Inglenook gas log input ratings are determined at sea level operation. The  
Inglenook gas logs do not require any operational changes up to and including 610 meters. Gas log  
operations above 610 meters require the Inglenook burners to be set as stated in TABLE 3. Exception: As  
permitted by the authority having jurisdiction.  
Canadian input ratings of this unit are determined at seal level operation. No Inglenook input rating needs  
to be change up to 4,500 feet above sea level in Canada. Installation of the Inglenook gas logs at altitudes  
above 4,500 feet is subject to field test of the individual installation and approval by the local authority  
having jurisdiction.  
Version 1.0b  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INGLENOOK GAS LOG KIT SPECIFCATIONS  
TABLE 3 provides specifications for both Inglenook natural gas and propane gas fuel log kits. The installer  
and homeowner must understand the differences in these kits both for the type of fuel being used and the  
impact that altitude has on specific fuel operations. Test procedures for verifying the fuel pressures are  
provided as part of the SIT 820 control valve operation provided in this manual. Contact a local authorized  
dealer or Country Flame direct to resolve any issues with specifications or the requirements thereof.  
TABLE 3:  
INGLENOOK LOG SET SPECIFICATIONS  
DESCRIPTION NATURAL GAS PROPANE GAS  
INPUT RATING (Btu/hr) 0 - 610 Meters*  
MIN INPUT RATING (Btu/hr) 0 – 610 Meters  
ORIFICE SIZE (DMS) 0 – 610 Meters front/rear  
MINIMUM SHUTTER SETTING (inches)  
PILOT ORIFICE (DMS)  
65,000  
42,600  
31/43  
0
65,000  
43,000  
48/55  
1/8  
51  
35  
INPUT RATING (Btu/hr) 610 – 1370 Meters  
ORIFICE SIZE (DMS) 610 – 1370 Meters  
59,000  
32/44  
58,700  
49/56  
MANIFOLD PRESSURE (Inches of Water Column)  
MANIFOLD PRESSURE, Low Setting (Inches of W.C.)  
MINIMUM INLET PRESSURE (Inches of W.C.)  
MAXIMUM INLET PRESSURE (Inches of W.C.)  
3.5  
1.4  
4.5  
7.0  
10.0  
4.2  
11.0  
14.0  
*ANSI standards are SAFETY STANDARDS not PERFORMANCE STANDARDS. Performance standards are defined as  
efficiency standards, A.F.U.E ratings, and efficiency test protocol that is established by the United States Department of Energy.  
SHUTTER SETTING  
Verify that the adjustable burner air shutter is set according to TABLE 3. FIGURE 4 shows the rear burner  
assembly (Item B) and the adjustable burner air shutter (Item A). Loosen the locking screw that holds the  
air shutter in place. Use a proper sized drill bit shank to set the correct opening of the air shutter. Retighten  
the locking screw. To set the burner air shutter for the front burner assembly, repeat the process.  
FIGURE 4: ADJUSTABLE BURNER AIR SHUTTER  
Version 1.0b  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION, BURNERS  
STEP 1:  
Once TABLE 1 has been filled in, once all parts have been removed from the Inglenook Fireplace and  
properly stored, then installation of the gas burner system can begin. FIGURE 5 shows the valve plate  
assembly that is to be installed in the bottom of the Inglenook in the direction of the arrows. This assembly  
includes the gas valve and gas line with front and rear gas orifices, the gas valve frame, the base plate, and  
the pilot valve assembly. This assembly should be placed through the grate opening and should sit squarely  
in the grate hole. If this assembly is not sitting square and flat in the grate recess, the rest of the burner  
installation will not be possible or could be installed incorrectly.  
FIGURE 5: BURNER INSTALLATION, STEP 1  
FIGURE 6 shows the valve plate assembly installed in the bottom of the Inglenook Fireplace.  
FIGURE 6: STEP 1 COMPLETE  
Version 1.0b  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEP 2:  
The ember tray and rear burner assembly are now ready for installation. This assembly includes steel tray  
framing, the rear burner assembly, including the gas tube. Refer to FIGURE 7 to view the installation of  
these parts. The installation is in the direction of the arrows shown in FIGURE 7.  
FIGURE 7: BURNER INSTALLATION, STEP 2  
FIGURE 8 shows the rear burner tray assembly installed and sitting properly in the bottom of the Inglenook  
Fireplace. Note that the gas tube of the rear burner must go through the slot in the right side of the floor and  
sit on top of the rear burner orifice mounted to the lower gas line. FIGURE 9 shows a close-up view of the  
rear burner adjustable shutter gas tube being set over the gas orifice. It is important that the person  
performing the installation ensure that the rear burner adjustable shutter tube is located properly over the  
rear orifice. If the tube is not placed properly over the orifice, the burner assembly will not sit correctly into  
the Inglenook Fireplace.  
FIGURE 8: STEP 2 COMPLETE  
FIGURE 9: GAS TUBE  
Version 1.0b  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEP 3:  
The front burner assembly is now ready for installation. This assembly includes the front burner tray and  
adjustable shutter gas tube. This front burner sits into the only opening left from the part installed in STEP  
2. It is important to ensure the adjustable shutter tube sit properly over the front gas orifice so that the front  
burner tray will sit flat into its opening. FIGURE 10 shows the front burner tray sitting in the Inglenook  
Fireplace. The front burner plate is blue in color and the rear burner plate is red in color in FIGURE 10.  
FIGURE 10: STEP 3 COMPLETE  
FIGURE 11 shows a close-up view of the adjustable shutter burner tubes and the front and rear gas orifices  
located along side the gas control valve. These gas tubes can be seen by looking into the ash box  
compartment where the gas valve assembly is located.  
FIGURE 11: BURNER TUBE AND FRONT/REAR ORIFICES  
Version 1.0b  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEP 4:  
In STEP 4 the log grate assembly is installed in the Inglenook. This assembly is to be set into the alignment  
slots provided. FIGURE 12 can be viewed for a look at the proper installation.  
FIGURE 12: LOG RETAINER, STEP 4 COMPLETE  
STEP 5:  
The control panel is installed in STEP 5. The control panel face plate covers the ash pan housing opening.  
FIGURE 13 shows the control panel faceplate installed. The control panel overlay, control knobs and  
switches have not been shown for clarity purposes.  
FIGURE 13: CONTROL PANEL, STEP 5 COMPLETE  
Version 1.0b  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION, EMBERS  
STEP 6:  
FIGURE 14 shows the embers installed on the front and rear burner. The embers add a “burning ash effect”  
to the log system when gas is burnt. Embers also help to break up the gas molecules as they pass through  
the front and rear burner plates and into the burn chamber where these gas molecules combine with oxygen  
to ensure complete combustion. From time to time, new embers will need to be purchased.  
FIGURE 14: EMBERS, STEP 6 COMPLETE  
Version 1.0b  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION, GAS LOGS  
STEP 7:  
STEP 7 begins the process of installing the six logs that make up the Inglenook log set. It is imperative that  
these logs are installed exactly as is shown in FIGURE 15 through FIGURE 21. Failure to install the gas  
logs correctly will cause the Inglenook gas log system to burn inefficiently. Inefficient gas burns can create  
a significant amount of soot. WARNING: Do not reconfigure the logs in any different formation other  
than what is shown in this manual. Each log can be located in the log retainer or with pins or has pins that  
need to be installed in it to ensure proper connection to the next log being installed.  
FIGURE 15: FIRST LOG INSTALLATION  
FIGURE 16: SECOND LOG INSTALLATION  
Version 1.0b  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE 17: THIRD LOG INSTALLATION  
FIGURE 18: FOURTH LOG INSTALLATION  
Version 1.0b  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE 19: FIFTH LOG INSTALLATION  
FIGURE 20: SIXTH LOG INSTALLATION  
Version 1.0b  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE 21: COMPLETED GAS LOG INSTALLATION  
The Inglenook gas log system installation is now complete. The installer can proceed to the first fire and  
lighting instructions on the next page. The entire system should be carefully monitored for the first several  
fires until the homeowner is convinced that everything is operating properly. If there are any signs that the  
Inglenook gas log system is not functioning properly at any time, immediately contact a local Country  
Flame Dealer, the gas company, or a certified gas technician to have any deficiencies corrected.  
Version 1.0b  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING: If you do not follow these instructions exactly, a fire or explosion  
may result causing property damage, personal injury, or loss of life.  
A. The Inglenook has a pilot light system that must be lit by hand.  
If you cannot reach your gas supplier, call  
the fire department.  
Follow these instructions exactly, when lighting the pilot.  
B. BEFORE LIGHTING the pilot light, it is important to smell all around  
the Inglenook for potential gas leaks. Be sure to smell next to the floor  
because some gas fuel is heavier than air and will settle to the lowest  
point.  
C.  
D.  
Use hand pressure to push in or turn the  
ON/PILOT/OFF control knob. Do not use a  
tool. If the control knob will not push in or  
turn by hand, do not attempt repair. Call a  
qualified service technician. Attempted repair  
may result in fire or explosion.  
Do not use the Inglenook if any part has been  
under water. Immediately call a qualified  
service technician to inspect the Inglenook  
and replace any part of the control system and  
any gas control that has been under water.  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any appliance.  
Do not touch any electrical switch; do not use any phone in your  
building.  
Immediately call your gas supplier from a neighbor’s phone.  
Follow the gas supplier’s instructions.  
LIGHTING INSTRUCTIONS  
1.  
2.  
3.  
4.  
STOP! Read the safety information above this section.  
8.  
Push in and turn the ON/PILOT/OFF control  
knob counterclockwise to “ON.”  
Close the Inglenook bottom grill.  
Turn on electrical power to Inglenook.  
The Pilot flame should be visible in the lower  
center between the logs.  
Turn off all electrical power to the Inglenook.  
9.  
10.  
11.  
Open the Inglenook bottom grill to expose the gas control panel.  
Push in on the ON/PILOT/OFF control knob slightly and turn  
clockwise to “OFF.”  
Wait five minutes to clear out any gas. Then smell for gas including  
near the floor. If you smell gas, STOP! Follow “B” of the safety  
information above.  
Turn ON/PILOT/OFF control knob counterclockwise to “PILOT.”  
Push in the ON/PILOT/OFF control knob and hold in. By repeatedly  
pressing the piezoelectric igniter, a pilot flame should appear. If  
flame goes out repeat steps 5 thru 10. If flame stays lit, go to Step 10.  
5.  
6.  
7.  
PILOT  
ADJ  
ON  
OFF  
IN  
OUT  
TO TURN OFF GAS TO INGLENOOK  
1.  
2.  
When servicing Inglenook, turn off electrical power.  
3.  
Push in ON/PILOT/OFF control knob and  
turn clockwise to “OFF.” Do not force.  
Close Inglenook bottom grill.  
Open the Inglenook bottom grill to gain access to control panel.  
4.  
FIRST FIRE  
Reduce odor by ventilating the room the first few times the unit is operated. Burn the first two fires no more than 15-  
20 minutes. Allow the Inglenook to completely cool between burns. Burn the third fire 30-40 minutes and allow  
proper cooling time. Operate the appliance according to the instructions contained in this manual.  
Version 1.0b  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE INSTRUCTIONS  
The frequency of performing Inglenook fireplace maintenance depends on site-specific conditions and the  
frequency of use. Country Flame recommends that a certified service technician perform an annual check-  
up prior to the start of each heating season. Both specific and general maintenance guidelines are presented  
in this section. If there are any questions about maintenance or proper service, contact a local authorized  
dealer, a certified service technician, or Country Flame direct for additional clarification. IMPORTANT:  
TURN OFF INGLENOOK POWER AND SHUT OFF THE GAS BEFORE SERVICING.  
SPECIFIC TASKS  
CLEANING BURNERS AND CONTROLS  
FREQUENCY:  
Once during annual inspection.  
PERFORMED BY:  
TASK PERFORMED:  
Qualified service technician.  
Clean the control compartment. Remove and clean logs (careful not to  
damage ceramic logs). While logs are removed, clean and inspect 2  
burners, inspect and clean pilot assembly, and inspect and clean  
surrounding burner area.  
REPLACE OLD EMBERS  
FREQUENCY:  
Once during annual inspection.  
PERFORMED BY:  
TASK PERFORMED:  
Qualified service technician.  
Replace ember material with new ember material. Additional ember  
material can be purchased from a local authorized Country Flame Dealer.  
(Only use genuine Country Flame ember material)  
CHECK FLAME AND PILOT  
FREQUENCY:  
Periodically.  
PERFORMED BY:  
Qualified service technician or homeowner.  
TASK PERFORMED:  
Visually inspect the burner’s flame height and burn patterns. The front and  
rear burner flames are steady and not lifting or floating away from the  
burner surfaces. Refer to FIGURE 5d for a picture representation of the  
proper flame with logs and embers installed. Visually inspect that the pilot  
light is burning with four blue flame nodes as shown in FIGURE 22,  
protruding from the pilot flame diffuser. No sputter or blockage of any  
pilot flame or its four nodes should be visible. If there is any abnormality  
observed in a flame pattern, contact a local authorized dealer or a certified  
technician.  
FIGURE 22: STANDING PILOT  
Version 1.0b  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHECK VENT SYSTEM  
FREQUENCY:  
PERFORMED BY:  
TASK PERFORMED:  
Once during annual inspection. See General Vent Inspection.  
Qualified service technician or homeowner.  
Check complete vent system for corrosion, moisture problems, pinholes or  
broken seals. Remove chimney cap and inspect vent and cap for debris.  
Ensure clean and open vent system.  
GENERAL INSPECTIONS  
GENERAL VENT INSPECTION  
Inspect the venting system periodically. Additional areas to inspect are as follows:  
1.  
Check areas of the venting system that are exposed to the elements for corrosion. These will appear  
as rust spots or streaks, and in extreme cases, can be holes. These components must be replaced to  
ensure the integrity of the system and the safety of the homeowner.  
2.  
3.  
Remove the chimney cap and shine a flashlight down the vent. Remove all debris, bird nests, or  
other foreign material found in the vent system.  
Check for evidences of excessive condensate, such as water droplets forming in the inner liner, and  
subsequently dripping out of vent joints. Continuous condensate can cause corrosion of caps, pipe  
and fittings. Condensation may be caused by having excessive horizontal runs, too many elbows,  
and exterior portions of the system being exposed to cold weather. Consult a certified professional  
to correct.  
4.  
5.  
Inspect joints, to verify that no pipe sections or fittings have been disturbed or consequently  
loosened. Also, check mechanical supports such as wall straps or plumbers' tape for proper  
integrity/support.  
For all direct vent systems, proper re-assembly and resealing of the vent-air intake system is  
mandatory. If the vent-air system is disassembled for any reason, reinstall each part per instruction  
provided for the initial installation.  
GENERAL CLEANING REQUIREMENTS  
Routinely perform general cleaning of the Inglenook to remove all dust, lint, or other debris that has built  
up during non-use or in the off-season. Clean the two burners per the specific tasks listed in this manual.  
Blow out the burners with dry air or carefully vacuum the burners to remove dust or other debris. If any  
burner damage or degradation is noted, contact a certified professional to verify their working order. No  
lubrication of any part is required in the Inglenook gas log system.  
Country Flame recommends that at a minimum, a certified professional conduct an annual inspection of the  
venting system. At no time should the Inglenook’s combustion air or ventilation air become obstructed.  
Free airflow is crucial to proper Inglenook operation. The pilot and burner flame patterns require  
inspection. Flame patterns should not appear suspended above the pilot tube or the burner surfaces. Nor  
should the pilot or burner flame appear lifeless or smoky in their burn pattern. Have the operational burn  
patterns checked by a certified professional in the event there is any question about gas burn patterns. Do  
not use the Inglenook if any part or component of this appliance has ever been under water. Immediately  
call a certified professional to inspect or replace any part or control system that has been under water.  
GENERAL SAFETY  
-Always shut off the gas supply and allow the heater to cool down before attempting any service work.  
-Always check for gas leaks, after servicing. Do not use a flame to check for gas leaks.  
-Always check for correct combustion and ventilation airflow after performing any service.  
-Always make sure the heater is away from any combustible or flammable materials.  
-Always ensure proper re-assembly and re-sealing of all vent-air intake parts. If any part of the system is  
disassembled, reinstall those parts per the instructions provided in this manual.  
Version 1.0b  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL PERIODIC INSPECTIONS  
Check the venting system annually and make sure the system is clear of any debris. Check flame patterns  
periodically. Allow 15 minutes for a flame to reach maximum color and height.  
GENERAL CLEANING, PAINTED SURFACES  
Occasionally dry rag dust the Inglenook to keep the painted surface looking new. Paint can be touched up  
as needed. Clean any area to be painted with fine steel wool. Remove all trim or cover all trim and controls  
with masking tape. Then, touch up the stove with Stove Bright® high temperature stove paint. Do not over  
paint as this will only lead to paint peeling problems.  
GENERAL CLEANING, PLATED SURFACES  
When cleaning plated trim, use special care to avoid damage. Do not use chemical or abrasive cleaners.  
Wipe only with a very soft damp cotton cloth to maintain original brilliance. CAUTION: Vigorous wiping  
may remove or discolor the plated finish.  
MAIN ORIFICES  
FIGURE 23 shows the valve plate assembly, Item E. This part is installed in the combustion chamber of  
the Inglenook fireplace. The pilot assembly, Item C, comes preinstalled into Item E. Inspect the wiring of  
the pilot assembly before installation to ensure all wires are properly connected to the gas valve. The gas  
control valve, Item D must be plumbed to the gas line cut-off valve that has been installed in the lower  
chamber of the Inglenook. The front burner spud orifice (Item A) and the rear burner spud orifice (Item B)  
need to be installed according to the fuel type that will be used. Refer to TABLE 3 to obtain the correct  
orifice size for both fuel and altitude requirements that site-specific location dictates. Item A and Item B are  
the front and rear spud orifices. Inspect them for the proper size for the gas being used.  
FIGURE 23: BURNER ASSEMBLY  
GAS FLAME INSPECTION  
The flames will be blue during the first 5 minutes or so but over a period of 15 minutes, the flame will  
gradually turn yellow. Flame intensity and the glowing logs vary with the specific type of fuel and venting  
conditions. Refer to FIGURE 5d for a picture that shows a proper flame for natural gas.  
IMPORTANT INFORMATION: IT IS NORMAL FOR GAS PRODUCTS, FABRICATED FROM  
STEEL, TO GIVE OFF SOME EXPANSION AND/OR CONTRACTION NOISES DURING THE  
START UP OR COOL DOWN CYCLE. SIMILAR NOISES ARE HEARD IN A FURNACE HEAT  
EXCHANGER OR CAR ENGINE.  
Version 1.0b  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROPANE FUEL CONVERSION INSTRUCTIONS  
The Inglenook gas log kit is shipped from the Country Flame factory set for 65,000 Btu/hr natural gas fuel  
usage; however, conversion kits may be purcahsed from Country Flame to convert the Inglenook gas log kit  
to different fuels; propane or natural gas. The Inglneook gas log conversion kit contains different  
repalcement parts depending on the fuel type specified. Fuel conversion requires adjustment to the control  
valve, the burners, and the pilot system. Refer to TABLE 3 for the correct gas pressures corresponding to  
the conversion kit being used.  
WARNING: Conversion kits shall be installed by a qualified service agency in accordance with the  
manufacturer’s instructions and all applicable codes and requirements of the authorized agency having  
juristriction. If the information in these instructions are not followed exactly, a fire, explosion or production of  
carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service  
agency is responsible for the proper installation of this kit. The installation is not proper and complete until the  
operation of the converted appliance is checked as specified in the owner instructions supplied with the kit.  
STEP 1  
STEP 2  
STEP 3  
Turn the control knob to the OFF position and turn off the gas supply to the valve.  
Remove control knob extentions from the valve. Allow system to cool before proceeding.  
Remove the control panel by removing the two screws located at the top of the panel.  
Disconnect the wire from back of piezoelectric igniter. Disconnect wires from on/off switch  
and variable speed control if required.  
STEP 4  
Refer to FIGURE 24 and using a Torx T20 screwdriver, remove and discard the three pressure  
regulator mounting screws (Item A), the pressure regulator tower (Item B), and the diaphragm  
assembly (Item C).  
FIGURE 24: SIT 820 NOVA mV GAS CONTROL VALVE  
STEP 5  
Refer to FIGURE 24. Ensure that the rubber gasket (Item D) is properly positioned and install  
the new HI/LO pressure regulator assembly to the valve using the supplied screws (Item E).  
Tighten screws securely.  
STEP 6  
STEP 7  
Attach the enclosed "conversion" label near the certification label.  
Re-attach all wiring to the fan control knob and the piezoelectric igniter. Replace the access  
panel and tighten the two screws. Replace the control knobs.  
STEP 8  
STEP 9  
Remove the door, the logs, and the embers, noting the position of each log as it is removed.  
Remove the two screws holding the ember tray in place. Lift up the ember tray and remove.  
Version 1.0b  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEP 10 Remove the two burners. Mark each burner as to their location. Refer to FIGURE 4 and  
TABLE 3 for proper air shutter adjustment for each burner. Adjust each burner’s air shutter to  
meet fuel conversion requirements. NOTE: Use the shank of an appropriately sized drill bit as  
an air shutter gauge. Pass the gauge through both sides of the air shutter, adjust and lock the  
shutter removing the gauge when finished making adjustments.  
STEP 11 Use a 3/8-inch (10mm) wrench to remove and discard the burner spud orifices. Place the new  
burner spud orifices in the appropriate location per the conversion kit instruction or refer to  
page 12 for the proper location of each labeled burner spud orifice.  
STEP 12 Remove and replace the pilot gas orifice located in the PILOT FLAME DIFFUSER BODY.  
a) Remove the pilot flame diffuser (FIGURE 25, Item B) by pulling up on it. The retainer  
clip (FIGURE 26, Item A) should release the pilot flame diffuser with a light pulling  
motion.  
b) Remove the pilot gas orifice (FIGURE 10, Item F) by using a 5/32 hex head wrench  
(Allen wrench) placed in the top of the pilot gas orifice.  
c) Verify the correct pilot gas orifice number per Page 11 kit definitions. Reinstall and  
tighten the new pilot gas orifice and replace the pilot flame diffuser by reinserting it  
into the retainer clip.  
FIGURE 25: PILOT VALVE (back side)  
FIGURE 26: PILOT VALVE  
STEP 13 Refer to FIGURE 27, Note (X). The piezoelectric igniter cannot be installed incorrectly unless  
it is damaged. The piezoelectric igniter should be in a parallel plane to the pilot flame diffuser  
body. Each time the igniter button is pressed, a blue arc should occur from the piezoelectric  
igniter to the pilot flame diffuser body. Replace the burners, the ember tray, the logs, the  
embers, and the door, ensuring correct position of all components.  
FIGURE 27: PILOT VALVE  
Version 1.0b  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEP 14 Open the gas supply and perform gas leak test. One of the best methods used to check for gas  
leaks is soap bubbles. Soap bubbles are made by mixing liquid detergent with a little water and  
shaking vigorously to create soap bubbles. Cover the gas pipe joint or valve component with  
these soap bubbles. If soap bubbles grow in size or the bubbles are blown off the connection, a  
gas leak exists. Make necessary repairs and retest until no change in soap bubbles is seen at  
any joint or valve connection. WARNING: DO NOT USE AN OPEN FLAME TO  
CHECK FOR GAS LEAKS  
STEP 15 Re-light the appliance. Check the flame control operation.  
NATURAL GAS CONVERSION  
If conversion is required from propane fuel to natural gas fuel, follow the same 15 steps listed in the section  
above using the proper Country Flame natural gas conversion kit. Adhere to the following:  
NOTE: Conversion kits are to be installed by qualified service technicians.  
NOTE: Do not install a kit IF conversion items are missing; check kit for all parts needed.  
NOTE: A Torx T20 Tamper-Proof screwdriver may be ordered separately if needed.  
THERMOSTAT/FAN CIRCUIT  
The Inglenook gas log control valve is pre-wired to accept a millivolt wall thermostat. This remote  
thermostat can be used to turn the Inglenook gas log system on and off automatically. If additional airflow  
is desired, purchase an optional Inglenook blower kit, part number IN-6200, directly from Country Flame or  
one of its local authorized dealers. Follow the instructions provided with the blower kit. The blower will  
automatically turn on when the heat sensing thermo-disc closes. The fan speed is controlled by the rheostat  
speed control. Connect the wall thermostat to the terminal block on the control valve as shown in FIGURE  
28 below. CAUTION: Label all wires prior to disconnecting them when servicing either the controls or the  
blower system. Wiring errors can cause improper and dangerous operational conditions. ALWAYS verify  
proper operation of the Inglenook gas logs, the control valve, the thermostat, and the optional blower after  
servicing is complete. If operational issues are noted after servicing is complete, DO NOT USE THE  
Inglenook until corrections are made.  
1/16" to 1/8"  
IGNITER  
PILOT BURNER  
THERMOCOUPLE  
THERMOPILE  
PIEZOELECTRIC  
IGNITER  
PILOT  
ADJ  
TH  
TP  
ON  
ON/OFF SWITCH  
OFF  
TP TH  
IN  
OUT  
OPTIONAL (millivolt)  
THERMOSTAT  
OPTIONAL (millivolt)  
REMOTE SENDER  
OPTIONAL (millivolt)  
REMOTE RECEIVER  
ON  
OFF  
FIGURE 28: THERMOSTAT WIRING DIAGRAM  
Version 1.0b  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING INSTRUCTIONS  
PROBLEM  
Pilot will not  
POSSIBLE CAUSE  
Air in gas lines  
SOLUTION  
Refer to Item #1 of the Set-Up Guide.  
light.  
Defective spill switch.  
Check for continuity across spill switch leads. Replace spill switch if  
excessive resistance is present or if circuit is electrically open.  
Refer to Item #2 of the Set-Up Guide.  
Wrong Inlet Pressure.  
Replace electrode if the insulator is cracked or the tip is corroded. Verify that  
the spark gap between the pilot and the electrode is correct.  
Defective piezo spark  
electrode.  
Defective piezo wire.  
Replace piezoelectric igniter if its wire insulation is damaged or the wire is  
broken or corroded.  
Safety interlock function  
engaged.  
Wrong inlet pressure  
Pilot adjustment screw not  
adjusted properly.  
Allow the thermocouple to cool until the mV drops below the hold-in  
requirements of the safety magnet, (30 seconds or less). Re-light pilot.  
Refer to Item #2 of the Set-Up Guide.  
Pilot will not  
hold.  
Refer to Item #7 in the Set-Up Guide.  
Thermocouple or thermopile Refer to Item #3 in the Set-Up Guide.  
not properly inserted into  
the pilot housing.  
Thermocouple or thermopile With the thermocouple and thermopile tips cool, clean the upper 3/8” with a  
has film build-up on tip.  
Electrical resistance too  
high.  
very fine emery cloth.  
Using a very fine emery cloth, clean thermopile and thermocouple  
connections at valve. Tighten thermocouple into valve hand tight, plus ¼ turn  
with a wrench.  
Verify that thermocouple is not kinked or damaged. Check open circuit  
voltage of thermocouple. Voltage should be between 18mV and 28mv. If  
voltage is less than 14mV, replace thermocouple.  
Refer to Item #7 in the Set-Up Guide.  
Defective thermocouple.  
(mV Plus systems)  
Defective thermopile.  
(Millivolt system)  
Defective safety magnet.  
(mV Plus systems)  
Verify operation of safety magnet in the following manner.  
Depress and hold pilot button.  
Verify open-circuit thermocouple voltage as described in previous step.  
Reconnect thermocouple to valve.  
Measure the voltage between the solder button on the base of the safety  
magnet, and the valve body. If the mV reading is above 6mV for vented  
appliances, or 8.5mV for un-vented appliances and the safety magnet does not  
hold, replace the valve.  
If closed circuit mV reading is the same as the open circuit reading, the coil is  
electrically open. Replace the valve.  
Defective Safety Magnet  
(Millivolt system)  
Verify operation of safety magnet in the following manner.  
Remove all wires from the terminals of the main operator.  
Measure the electrical voltage between the terminals TPTH and TP. If the  
voltage is above 110mV and the safety magnet does not hold, replace the  
valve.  
Pilot orifice blocked.  
Replace orifice with a new orifice of the exact size and type.  
Pilot light  
drops out.  
Wrong pilot orifice installed Replace the orifice with a new orifice supplied specifically for the appliance  
in pilot light.  
and gas type in question.  
Spill switch activated.  
Examine the venting system. Repair as necessary.  
Version 1.0b  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING INSTRUCTIONS (cont’d)  
PROBLEM  
No gas to main  
burner.  
POSSIBLE CAUSE  
Gas pressure to appliance is  
low.  
SOLUTION  
Refer to Item #2 in the Set-Up Guide.  
Thermostat or  
wall switch will  
not cycle main  
burner  
Pilot not lit.  
Light pilot and wait for thermopile to heat up sufficiently to power the main  
operator. If pilot fails to light, or hold, refer to above sections.  
Rotate OFF/PILOT/ON control knob to the ON position.  
Control knob not in ON  
position.  
Thermostat not in the ON  
position.  
Turn thermostat to ON, and adjust temperature control to call for heat.  
Thermopile output voltage not Refer to Item #7 in the Set-Up Guide. If unable to meet minimum  
within design parameters.  
Defective thermostat or  
thermostat wiring.  
thermopile requirements, replace thermopile.  
(A) With the pilot adjusted properly, (Refer to Item #7 in the Set-Up  
Guide) place a jumper wire between TPTH and TH. Measure the  
voltage (millivolt) reading across the TPTH and TP terminals on  
the control valve. This voltage should not fall below 300mV.  
Record reading.  
(B) Remove the jumper wire from the TPTH and TH connections and  
reconnect the thermostat wires to the same terminals. Measure the  
voltage (millivolt) reading across the TPTH and TP terminals on  
the control valve. This voltage should not fall below 150mV. If  
reading is below 150mV the source of excessive resistance must  
be located and removed. (bad connections or bad wires)  
Repeat the troubleshooting items covered under “Defective thermostat or  
thermostat wiring,” Use the exact same procedures but substitute the word  
“wall switch” where the word thermostat appears.  
Defective wall switch.  
Excessive wire resistance.  
Valve wired wrong.  
Make certain that all mV connections are made using wire of the proper  
AWG size. (Refer to the Trouble-Shooting Guide.)  
Thermopile leads must be connected to the TPTH and the TP connection of  
the main control valve. Thermostat wires must be connected to the TPTH  
and the TH terminals of the main control valve.  
Main operator coil defective.  
Verify the electrical resistance of the main control valve operator coil in the  
following manner:  
(A) Remove all wires from the control valve head.  
(B) With an ohmmeter, measure the electrical resistance between TP  
and TH terminals. If the resistance does not fall within  
specifications shown in the Troubleshooting Guide, replace valve.  
Check the appliances installation instructions provided by the manufacturer  
to verify that the proper flue dimensions are within specification and that  
proper combustion make-up air is provided for the particular appliance.  
Verify that the appliance’s flue ins installed according to manufacturer’s  
instructions.  
Main burner  
Flue gas spillage present in  
combustion chamber. (Non-  
DV appliances only)  
cycles on and off.  
System not on  
thermostat.  
Check the flue or the combustion air intake for blockage. Clean as  
necessary.  
Main burner lights Debris or damage to seat of  
Replace the control valve assembly.  
in the PILOT  
position of the  
control valve.  
main valve.  
Main seat blown out because  
of exposing LPG gas valve to  
unregulated line pressure in  
excess of 15 psig.  
Replace the control valve assembly.  
Version 1.0b  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE-SHOOTING GUIDE  
The 820 Nova millivolt control valve is available in three different configurations. They are the (1)  
Millvolt Plus vented, or the (2) Millivolt Plus vent-free, or the (3) Millivolt systems.  
The Millivolt Plus vented system is for use in direct vent appliances that require fast shut-off in the  
even of a pilot flame failure. A thermocouple powers the safety magnet and a thermopile powers the  
main control valve.  
The Millivolt Plus vent-free system is used in conjunction with an ODS pilot. As with the vented  
Millivolt Plus control valve, this valve uses a thermocouple to power the safety magnet and uses a  
thermopile to power the main control valve.  
The Millivolt system is used with gravity vented appliances where rapid shut-off is not necessary in the  
event of a pilot flame outage. It uses a single thermopile to power both the safety magnet circuit and  
the main control valve. A spill switch could be used in the safety magnet circuit of this system.  
All NOVA control valves are fitted with a safety interlock device that prevents unsafe ignition of the  
pilot burner after the ON/PILOT/OFF control knob is turned to the OFF position. All three of these  
control valves can accommodate a wall switch, or a wall thermostat, or a remote control unit that can be  
used to cycle the main control valve on and off. Following is the electrical data for the 820 Nova  
millivolt gas control valve models:  
VALVE TYPE  
NOVA mV Plus  
Vented  
MAIN CONTROL VALVE  
SAFETY MAGNET  
Minimum Voltage  
145 mV  
Hold-in current  
Less than 285mA  
Greater than 125mA  
0.018±0.003Ω  
Coil Resistance  
2.25±0.5Ω  
Drop-out current  
Coil resistance  
NOVA mV Plus  
Un-vented  
Minimum Voltage  
Coil Resistance  
145 mV  
2.25±0.5Ω  
Hold-in current  
Drop-out current  
Coil resistance  
Less than 200mA  
Greater than 80mA  
0.018±0.003Ω  
NOVA Millivolt  
Vented  
Minimum Voltage  
Coil Resistance  
145 mV  
2.25±0.5Ω  
Hold-in current  
Drop-out current  
Coil resistance  
Less than 12mA  
Greater than 4mA  
10.2±0.05Ω  
All millivolt control valve circuits are easily affected by electrical resistance. If enough resistance is  
present in the appliances circuit, two things can occur. (A) Either the main control valve will work  
intermittently and be unpredictable or (B) the main control valve will not work at all. There are several  
areas where excess resistance can be found in the appliances circuit. In new installations, the  
thermostat itself can be found to be the problem. Always use a thermostat rated for millivolt control as  
they have been designed to minimize circuit resistance. The other area to check is the wiring itself.  
Wire gage plays an important part in wire resistance. The smaller the diameter of the wire and the  
greater the length of the wire, the larger the circuit resistance will be. The table above provides  
valuable information to select the proper wire that is used to connect to the main control valve. This  
table refers to the total length of wire from the control valve out to the thermostat and back to the  
control valve. All electrical connections must be tight, clean, and free from corrosion. Corrosion can  
build up over time due to humidity problems so inspect wire connections on an annual basis.  
WIRE SIZE  
12 Gauge  
14 Gauge  
MAXIMUM LENGTH  
WIRE SIZE  
18 Gauge  
20 Gauge  
MAXIMUM LENGTH  
150 feet  
100 feet  
64 feet  
40 feet  
25 feet  
16 feet  
16 Gauge  
22 Gauge  
Version 1.0b  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOVA mV SET-UP GUIDE  
The following information is provided to assist in the set-up of the 820 NOVA mV control valve. A certified  
professional should install, perform conversions, and verify the proper operation of all Country Flame gas  
appliances. If there are any questions, please contact a local authorized dealer or Country Flame direct for  
assistance.  
1. Bleed all air from gas lines before starting the system.  
2. With the main burner in operation, adjust the inlet pressure regulator to supply gas to the appliance within the  
design parameters of the appliance as dictated by site-specific requirements. (Typically 7”W.C. NG and  
11”W.C. LPG.)  
3. Make certain that the thermocouple and thermopile are fully inserted and tightened into their respective  
holders in the pilot head. The thermocouple should be threaded into the valve hand-tight, and ¼ turn of the  
wrench.  
4. Verify that the system is wired properly and that all connections are clean and tight. Thermopile leads are to  
be connected to the TPTH and TP connections of the main control valve. Thermostat and wall switch wires  
are to be connected to the TPTH and the TH terminals of the main control valve.  
5. Turn the OFF/PILOT/ON control knob to the PILOT position and depress the knob while lighting the pilot  
with a match or the piezoelectric igniter switch.  
6. Continue to hold the OFF/PILOT/ON control knob in (depressed) until enough current is generated by the  
thermocouple to engage the safety magnet. Remember: the Millivolt Plus system uses a thermocouple to  
power the safety magnet and the Millivot system utilize power from a single thermopile to engage the safety  
magnet.  
7. After the pilot flame has been lit for approximately three minutes and with only the thermopile wires  
connected to the main control valve, measure the voltage across the TPTH and TP terminals. The open  
circuit voltage should read between 500mV and 750mV. Adjust the pilot adjustment screw until the voltage  
reading falls within these parameters. (Counterclockwise increases the voltage reading and clockwise  
decreases the voltage reading.)  
8. With the pilot flame adjusted properly, place a jumper wire between the TPTH and the TH connections. Take  
a voltage reading across the TPTH and the TP terminals on the main control valve. This closed circuit  
voltage should remain above 300mV.  
9. Remove the jumper wire used in Step 8 that was connected from the TPTH and TH terminals and reconnect  
the thermostat and wall switch wires to the same terminals. Take a closed circuit voltage reading as described  
in Step 8. This closed circuit voltage reading should remain above 175mV.  
10. Rotate the OFF/PILOT/ON knot to the ON position. The main burners should light.  
11. Verify the operation of the thermostat and wall switch by cycling each individually. Observe the operation of  
the main burner during the cycling of the thermostat and wall switch.  
12. Rotate the OFF/PILOT/ON knob to the OFF position. Both the pilot flame and the main burner flames  
should be immediately extinguished.  
13. Refer to the wiring diagrams provided in this manual as needed.  
Version 1.0b  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY LABEL  
FIGURE 29: CONTROL PANEL OVERLAY  
Version 1.0b  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACEMENT PARTS – INGLS 24N or INGLS 24P  
When requesting service or replacement parts for your fireplace, please provide model number and  
serial number. All parts listed in this manual may be ordered from an authorized dealer.  
PART  
Figure 30, Item 1  
Figure 30, Item 2  
Figure 30, Item 3  
Figure 30, Item 4  
Figure 30, Item 5  
Figure 30, Item 6  
Figure 15 -21, Item 7  
Figure 14, Item 8  
PART DESCRIPTION  
EMBER TRAY ASSEMBLY  
PART NUMBER  
IN-6529  
IN-6505  
IN-6506  
IN-6528  
IN-6520  
IN-6527  
IN-6521  
IN-6526  
IN-6522  
IN-6523  
IN-6525  
IN-6530  
BACK BURNER ASSEMBLY  
FRONT BURNER ASSEMBLY  
GAS VALVE PLATE ASSEMBLY  
GRATE ASSEMBLY  
CONTROL PANEL FACEPLATE  
LOG SET  
EMBERS  
ON/OFF PILOT EXTENSION KNOB  
HI/LOW EXTENSION KNOB  
PIEZO IGNITER  
MODEL #1650 N DORMONT FLEX  
CONNECTOR GAS LINE  
CONVERSION KIT (to propane)  
CONVERSION KIT (to natural gas)  
GAS VALVE (CNG)  
Item 9  
Table 2a  
Table 2b  
IN-6503  
IN-6504  
GC-3905  
GC-3906  
GAS VALVE (LPG)  
FIGURE 30: INGLENOOK GAS LOG PARTS  
Version 1.0b  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED 10 YEAR WARRANTY  
To establish warranty dates a completed warranty card must be received at Country Flame Technologies, 900 George  
Street, Marshfield, MO 65706, within 60 days of the date of original retail purchase of the Inglenook gas log set.  
Failure to provide this warranty card within the timeframe specified may require the original retail purchaser to prove  
the date of installation before any warranty work can be performed.  
The warranty exclusions and limitations of liability are effective upon installation of the fireplace.  
Subject to the conditions set forth herein, Country Flame Technologies extends the following warranty with respect to  
Country Flame Inglenook Gas Products.  
If Country Flame Technologies is reasonably satisfied that any part or portion of the fireplace covered by this Limited  
Warranty is defective in material or workmanship under normal use and service as described in the Operating  
Instructions, Country Flame Technologies will take the following actions:  
1. If the defect is reported during the first year from the date of installation (stainless steel burners and fiber logs are  
covered for 2 years), Country Flame Technologies will replace or repair the defective components at its sole expense.  
The decision whether to replace a component will be made at Country Flame Technologies’ sole discretion. Country  
Flame’s Limited Warranty does not cover components broken during shipping, misuse or careless handling. Country  
Flame Technologies shall not be responsible for any indirect, incidental, or consequential damages or for any costs  
other than those incurred by Country Flame Technologies to repair or replace the defective component. If components  
(including venting) other than factory-approved components are used, all warranties on the Inglenook fireplace system  
are voided. Defects reported after the first year will not be covered by warranty unless they fall within the  
purview of paragraph 2 or 3 below.  
2. If the following defects are reported during the second year after the date of installation, Country Flame Technologies  
will supply replacement parts at the current wholesale price: defective electrical or manual components, optional  
components or accessories (not including glass panels broken during misuse or careless handling). Country Flame  
Technologies shall not be responsible for any labor, transportation or other costs. Furthermore, Country Flame  
Technologies will not be liable for any indirect, incidental or consequential damages.  
3. Country Flame Technologies will replace or repair defective burners, burner associated parts, decorative log grates, or  
other steel components, at anytime during ten (10) years from the date of original installation. The decision whether to  
replace or repair the defective component shall be made at Country Flame Technologies’ sole discretion. Country  
Flame Technologies shall not be responsible for any indirect, incidental or consequential damages or for any costs  
other than those incurred by Country Flame Technologies to repair or replace the defective component.  
This Limited Warranty is the exclusive remedy available to you. If Country Flame Technologies cannot effectively  
resolve a warranty problem in an expedient and cost-effective manner, it can discharge its entire warranty liability by  
refunding the price of the product to you.  
Products made by other manufacturers, whether sold with the Inglenook fireplace or added thereafter, are NOT  
covered by this Limited Warranty. The use of other unauthorized components will make this warranty null and void.  
This Limited Warranty will also be void if the Inglenook or any of its components are not installed by a qualified  
installer in accordance with the Installation Instructions. Furthermore, the Limited Warranty will be void if the  
fireplace is not operated, at all times, and according to the Operating Instructions furnished with the fireplace. Any  
service work must be performed by authorized service representatives.  
EXCEPT TO THE EXTENT PROVIDED BY LAW, NO OTHER EXPRESS OR IMPLIED WARRANTIES,  
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL  
APPLY TO THE FIREPLACE PRODUCT. In States that do not allow limitations on how long an implied warranty  
lasts, or do not allow exclusion of indirect damages, those limitations or exclusions may not apply to you. You may  
also have additional rights not covered in this Limited Warranty.  
Country Flame Technologies reserves the right to make changes at any time, without notice, in design, material,  
specifications and prices. It also reserves the right to discontinue styles and products.  
Version 1.0b  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Contec Universal Remote RT U60C User Manual
Craftsman Chipper 24777588O User Manual
Craftsman Portable Generator 919679580 User Manual
Creda Ventilation Hood CRC65 User Manual
Cres Cor Refrigerator R171S1828 User Manual
Cypress Clock CY7B9911V User Manual
Directed Audio Car Amplifier 200 500 User Manual
Electro Voice Portable Speaker MC12 User Manual
ETA Systems Surge Protector PS220 User Manual
GE Answering Machine 27851FE1 User Manual