Cooper Lighting Indoor Furnishings Area Luminaire User Manual

Talon  
Area Luminaire  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SITE + PARKING | ROADWAY | PATH OF EGRESS  
IMPENETRABLE FORM  
INNOVATIVE FOREFRONT  
Coupling precise mechanical design with  
premium quality materials, the Talon site light  
is constructed to sustain the rigors of outdoor  
operation. Thick wall die-cast aluminum  
construction and channel set silicone gasketing  
form an impenetrable IP65 barrier optimizing  
optical efficiency and fixture longevity in the  
harshest of environments.  
Forward Leaning— two words that describe  
Streetworks’ product development process  
and relentless commitment to providing  
progressive solutions for emerging market  
trends. Regardless of the ordinance governing  
your site—spill control, emergency egress,  
energy efficiency or curfew compliance, the  
Talon offers progressive features to address  
rigorous regulatory needs.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
4
PERFORMANCE + VERSATILITY  
OPTICAL VERSATILITY  
MAXIMIZE SITE UNIFORMITY  
Never before has a single luminaire  
supported this magnitude of optical  
choices, touting four [4] distinct families  
of optical assemblies, all with compelling  
performance. Hydroformed, segmented,  
vertical and specialty application optical  
systems allow finely tuned site lighting  
solutions with unprecedented levels of  
uniformity and control.  
Add sparkle to your site and maximize  
pole spacings with sag glass optical  
systems offered in both cutoff and  
semi-cutoff configurations.  
For applications mandating full cutoff,  
choose from a complete offering of flat  
glass vertical lamp solutions. The vertically  
lamped family of optical systems  
minimizes light levels directly below  
the luminaire while increasing lateral  
illumination, maximizing overall site  
uniformity. Available in Type III, Area  
Round, Area Square, Type IV and  
Automotive Front Row [TLU only]  
distributions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPTICAL SOLUTIONS AS DIVERSE AS THE ENVIRONMENTS THEY ILLUMINATE.  
Exterior lighting requirements continue to grow more stringent with added emphasis on light control and system efficiency. Whether the goal of your  
site lighting design is safety, general illumination or highlighting prominent features, Talon offers application-specific optical solutions that provide the  
highest level of photometric performance and control.  
ROTATIONAL FLEXIBILITY  
LEADING SPILL CONTROL  
GET NOTICED  
Maintain uniform site spacing and  
fixture orientation with rotatable optical  
assemblies. All optics are capable of  
rotating in 90° increments allowing for  
manipulation of distribution orientation  
independent of fixture position.  
The Spill Light Eliminator [SL] optic is the  
industry leader in effective spill light  
control, eliminating light beyond one [1]  
mounting height behind the pole with no  
sacrifice in forward illumination. Used  
along site perimeters and property lines,  
the Spill Light Eliminator keeps the light  
inside and the darkness out.  
Accel Optics, the Talon’s family of  
automotive reflector solutions specialize in  
focused front row product displays that  
engage the customer, general merchandise  
lighting that creates an inviting dealership  
appearance emanating safety and security,  
and perimeter lighting that precisely  
frames the automotive dealership lot.  
DARK SKY FRIENDLY  
For applications requiring dark sky friendly  
solutions, look to full cutoff flat glass  
optical assemblies providing focused  
illumination with zero uplight and minimal  
high angle illumination while retaining  
superior uniformity. Available in  
hydroformed or segmented Type II, III, IV,  
V and SL distributions.  
NOTE: In Flat Glass configurations only.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
6
QUALITY + DURABILITY  
DURABLE CAST CONSTRUCTION  
Low-copper alloy die-cast aluminum  
construction offers corrosion resistance  
while precise tolerance control ensures  
tight nesting of the door and housing.  
Combining heat extracting reveal channels  
with independent optical and electrical  
chambers that isolate heat producing  
sources, the Talon’s housing design is  
both functionally relevant and aesthetically  
pleasing.  
RIGID OPTICAL CONSTRUCTION  
A commitment to optical research and  
precision build quality result in unequaled  
levels of performance and repeatability.  
A rigid box enclosure shields segmented  
optical facets on all sides from performance  
degrading damage while each facet bank is  
secured to both the top and bottom of the  
enclosure providing repeatable facet  
orientation relative to light center.  
PREMIUM MATERIALS  
Superior optical design and a commitment  
to premium 95% reflective sheet aluminum  
make Talon’s segmented reflector family  
the benchmark of optical excellence.  
Reflector facets are flat and unobstructed  
by rivets or other means of attachment  
which may cause streaks or striations in  
the light distribution. First class  
construction and attention to detail  
ensure dependable performance in  
every installation.  
TOOLLESS ENTRY  
Invisibly integrated door retaining latches  
allow for a consistent outward aesthetic  
while providing maintenance-friendly,  
toolless entry into the optical and  
electrical chambers. The corrosion-  
resistant stainless spring steel latch  
and door receiver pin create an audible  
engagement confirming secure door  
closure and fixture sealing.  
INGRESS PROTECTION  
“IP” stands for Ingress Protection and is a  
rating system recognized internationally  
as the standard for electrical products  
and other related technologies. The two  
numbers proceeding the “IP” individually  
callout the fixture's protection rating  
against moisture and airborne  
particulates. The channel set silicone  
gasketing system incorporated in Talon  
is IP65 certified. Dust, insects and  
moisture simply have no chance of  
penetrating the outer enclosure.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONFIDENCE-INSPIRING QUALITY BEYOND THE SUM OF ITS PARTS.  
From the stainless steel hinges to the rugged housing, every detail of the Talon construction is precisely designed with industry leading craftsmanship.  
Heavy-wall die-cast aluminum construction, premium TGIC [triglycidyl isocyanurate] polyester powder coat paint and an IP65 rated optical cavity ensure  
Talon can endure the harshest environments.  
FINISH OPTIONS  
Color Retention Over Time  
100  
96  
Streetworks’ premium polyester powder coatings are enhanced  
TGIC based coatings formulated to withstand extended outdoor  
exposure. The powders are designed not only to be functional, but  
decorative, combining good film appearance with excellent mechanical  
and exterior exposure qualities. Formulated with properties similar to  
a standard TGIC, the improved weathering characteristics of premium  
TGIC result from the integration of a new polyester resin technology.  
These coatings consistently display at least twice the gloss retention  
of standard TGIC materials in both weatherometer and QUV testing,  
making them ideal for outdoor lighting fixtures and poles. Applied to  
a nominal 2.5 mil thickness, Talon’s six (6) standard finishes offer  
superior protection against fade and wear.  
92  
88  
84  
0
6
12  
18  
24  
Months Exposure  
TGIC  
Streetworksʼ Premium  
GREY [AP]  
BLACK [BK]  
BRONZE [BZ]  
WHITE [WH]  
DARK PLATINUM [DP]  
GRAPHITE METALLIC [GM]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
8
CONTROL + EFFICIENCY  
Uplight  
LUMINAIRE CLASSIFICATION  
The IESNA’s revised Luminaire Classification System  
[TM15-07 revised] creates a new basis of measurement  
for site lighting visibility and adjacent property  
interaction. This technical memorandum subdivides  
the luminaire distribution into smaller angular zones  
and subzones to more clearly represent how much  
light is emitted at various angles. The values for each  
subzone give an indication of the appropriate use for  
the luminaire within an application. For dark sky  
sensitive areas, the uplight component tells how  
much the luminaire will contribute to sky glow.  
For applications with strict light trespass regulations,  
the back light portion of the distribution helps  
180°  
UH  
100°  
90°  
100°  
90°  
determine how much light will reach neighboring  
properties. Talon reflector assemblies keep light on  
task by contributing as little as 0.0% total upward  
illumination and 0.8% total backlight.  
UL  
UL  
BVH  
FVH  
Forward Light  
80°  
80°  
Forward Light Low [FL]  
Forward Light Mid [FM]  
Forward Light High [FH]  
Forward Light Very High [FVH]  
BH  
FH  
60°  
60°  
BM  
FM  
Back Light  
Back Light Low [BL]  
Back Light Mid [BM]  
Back Light High [BH]  
Back Light Very High [BVH]  
Back  
Forward  
BL  
FL  
30°  
30°  
0°  
[nadir]  
Uplight  
Uplight Low [UL]  
Uplight High [UH]  
NEIGHBORHOOD AND DARK SKY FRIENDLY  
National organizations work to educate the general public on best lighting practices in order to minimize light trespass, reduce sky-glow and improve  
nighttime visibility through glare reduction. Experts understand the visual system adapts to surrounding ambient conditions, spurring a move from  
universal light level recommendations to a set of custom tailored guidelines for each task based on an applications’ lighting zone. When surrounding  
conditions are dim, lower levels of light are able to be detected more easily. In these environments, high light level applications can be a source of  
discomfort and glare. Careful selection and placement of luminaires eliminates glare and creates a comfortable nighttime environment. Talon’s  
assortment of specialty light control optical assemblies combined with a wide array of internal or external house-side shields provide the perfect  
solution for every application.  
Glare  
Light Trespass  
Property  
Line  
Uniform Task Illumination  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEPPING UP TO THE CHALLENGE.  
As visual research advances so too the core understanding of how light interacts with surrounding communities and nocturnal environments.  
Utilizing this knowledge, Federal programs, national organizations and industry leaders institute guidelines for illuminating an area safely and  
securely while reducing energy, eliminating spill light and minimizing glare. Talon steps up to the challenge, offering innovative solutions to regulatory  
compliance issues.  
ENERGY EFFICIENCY  
With the Federal Energy Independence and Security Act effective January 1, 2009, states are rapidly adopting energy legislation limiting the use of probe  
start sources in favor of higher efficiency options. Pulse start technology is being embraced for its efficacy, extended life, high lumen maintenance, and  
color consistency. The increased color rendering of a pulse start lamp improves visibility and heightens the overall safety and security of the site. Higher  
lumen maintenance levels reduce the number of fixtures needed to achieve a consistent light level over the fixture’s installed life. Initial savings are  
compounded by decreased energy consumption and less frequent maintenance requirements. By supporting a full array of both horizontal and vertical  
lamp distributions, Talon offers the broadest selection of energy saving pulse start solutions.  
Lumen Output Over Time  
120  
100  
80  
60  
40  
20  
0
0
2000  
4000  
6000  
Hours of Operation [4000 hours ~ 1 year]  
1000W Probe Start MH  
8000  
10000  
12000  
14000  
16000  
18000  
750W Pulse Start MH  
CURFEW COMPLIANCE  
Certain regulatory documents incorporate energy saving measures beyond standard source efficacy, including curfew regulations calling for close  
of business site lighting power reduction. When alternating luminaires are turned off to accomplish the reduction, site lighting uniformity is greatly  
reduced, compromising visibility and the feeling of security. The Talon Hi/Low [HL] option enables curfew compliance through an integrated  
dimming relay internal to the housing that reduces power while closely maintaining critical-to-safety site lighting uniformity levels.  
Alternating Fixture Switching  
Hi/Low Dimming  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
12  
SPECIFICATION FEATURES  
MOUNTING  
OPTICAL SYSTEMS  
ELECTRICAL  
Extruded 8" [TMU Talon Medium] or 10  
1/2" [TLU Talon Large] aluminum arm  
includes internal bolt guides allowing  
for easy positioning of fixture during  
installation to pole or wall surface.  
Standard single carton packaging of  
housing, square pole arm and round  
pole adapter for contractor friendly  
arrival of product on site.  
Choice of fourteen [14] high efficiency  
optical systems utilizing horizontal and  
vertical lamp orientations, including five [5]  
optional high efficiency segmented optical  
systems constructed of premium 95%  
reflective anodized aluminum sheet.  
Optical segments are rigidly mounted  
inside a thick gauge aluminum housing for  
superior protection. All segment faces are  
clean of rivet heads, tabs or other means  
of attachment which may cause streaking  
in the light distribution. Standard with  
mogul-base socket for HPS and  
TMU offered standard with ballast and  
related electrical componentry hard  
mounted to die-cast housing for optimal  
heat transfer and improved operating  
efficiency. TMU optional and TLU standard,  
electrical componentry mounted to a  
swing-down galvanized steel power tray  
with integral handle. Electrical disconnects  
allow tray to be completely removed from  
the housing providing ample hand and  
tool room for attachment of fixture during  
installation.  
CONSTRUCTION  
Heavy-wall, die-cast low-copper alloy  
aluminum construction with integral  
reveal channels along top surface of  
housing to promote heat extraction and  
prolong electrical component life. Internal  
cast-in wall separates optical and electrical  
chambers, allowing components to operate  
cooler. One-piece heavy-wall, die-cast  
aluminum door frame with integral cast-in  
gasket channel seals optical chamber to an  
IP65 rating. Stainless steel latches and  
hinges.  
175-1000W MH. Standard with  
medium-base socket for 150W MH and  
below. All optical modules feature quick  
disconnect wiring plugs and are field  
rotatable in 90° increments.  
TALON MEDIUM [TMU]  
Standard Door 70-200W  
TALON LARGE [TLU]  
Lamp  
250-400W  
Lens Type  
Lamp  
250-1000W  
Lens Type  
Distribution  
Orientation  
Configuration  
Recessed  
Recessed  
Recessed  
Recessed  
Recessed  
Recessed  
Recessed  
Recessed  
Recessed  
Deep  
Lens Type  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Orientation  
2F  
2S  
3F  
3S  
4F  
4S  
5F  
5S  
SL  
AR  
AS  
3V  
4V  
AF  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Vertical  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Sag  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Horizontal  
Vertical  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Flat/Sag  
Vertical  
Deep  
Sag  
Vertical  
Vertical  
Deep  
Sag  
Vertical  
Vertical  
Deep  
Sag  
Vertical  
Horizontal  
Recessed  
Flat/Sag  
Vertical  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Certifications  
IP65 Rated U.L. 1598 Listed ISO 9001  
CSA Listed  
25°C Ambient  
NOTE: In Flat Glass configurations only.  
DRILLING PATTERNS  
Type “M”  
FINISH  
Wall Mount  
Housing and arm finished in a 5 stage  
premium TGIC polyester powder coat  
paint, 2.5 mil nominal thickness for  
superior protection against fade and  
wear. Standard colors include black,  
bronze, grey, white, dark platinum,  
and graphite metallic.  
BK  
AP  
2 5/16"  
[59mm]  
Black  
Grey  
12"  
3/4" [20mm]  
dia. hole  
2 7/16" [124mm]  
[305mm]  
4 7/8"  
[124mm]  
BZ  
WH  
10 1/2"  
[267mm]  
4 7/8" [124mm]  
Bronze  
White  
[2] 5/8" [16mm]  
dia. holes  
6 1/2"  
[165mm]  
8"  
9/16" [14mm]  
Dia. Hole [4]  
DP  
GM  
Dark Platinum  
Graphite Metallic  
[203mm]  
MOUNTING CONFIGURATIONS  
Talon is available in seven [7] unique luminaire mounting configurations.  
Wall Mount  
Arm Mount Single  
E.P.A.  
Arm Mount 2 @ 180°  
E.P.A.  
Arm Mount 2 @ 90°  
E.P.A.  
Arm Mount 3 @ 120°  
E.P.A.  
Arm Mount 3 @ 90°  
Arm Mount 4 @ 90°  
E.P.A.  
E.P.A.  
TMU  
TMU  
TMU  
TMU  
TMU  
TMU  
Recessed Door 1.22  
Recessed Door 2.44  
Recessed Door 2.44  
Recessed Door 3.23  
Recessed Door 3.23  
Recessed Door 3.63  
Deep Door  
1.45  
2.51  
Deep Door  
2.90  
5.02  
Deep Door  
2.90  
5.02  
Deep Door  
3.92  
6.85  
Deep Door  
3.92  
6.85  
Deep Door  
4.43  
7.77  
TLU  
TLU  
TLU  
TLU  
TLU  
TLU  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
14  
OPTIONS + ACCESSORIES  
[MS]  
[Arm Mount]  
[WM]  
ARM MOUNT  
TENON ADAPTER  
PHOTOCONTROL RECEPTACLE [4]  
Standard 8" [TMU] or 10 1/2" [TLU]  
extruded aluminum arm features internal  
bolt guides for twin support rods. Round  
pole mounting accommodated by utilizing  
provided round pole adapter between the  
fixture arm and pole shaft.  
Tenon adapters available to slip fit over poles  
equipped with nominal 2" pipe size steel tenon  
[2 3/8" O.D., 4" length] or nominal 3" pipe size  
steel tenons [3 1/2" O.D., 5" length]. Adapter  
secures to tenon via six [6] stainless steel  
bolts. For complete configuration availability,  
see Tenon Adapters on page 14.  
Fixtures available with gasketed photocontrol  
receptacle for mounting a standard NEMA  
photocontrol [ordered separately]. Medium  
housing also available with a button-style  
photocontrol [P].  
INTERNAL HOUSE-SIDE SHIELD [B]  
Internal house-side shield reduces light  
concentration behind the pole while  
maintaining street side efficiency. Internal  
house-side shields available on Type II, III, IV  
and AF distributions.  
EXTERNAL MAST ARM ADAPTER [MS]  
Cast aluminum mast arm adapter secures  
fixture head to nominal 2" [2 3/8" O.D. pipe  
size] horizontal steel tenon arm. Adapter  
casting slip fits over tenon arm and is  
secured via two [2] stainless steel bolts.  
POLYCARBONATE VANDAL SHIELD [V]  
Internally mounted 3/16" thick molded  
polycarbonate lens, treated with UV inhibitor  
to discourage the gradual discoloration that  
results from exposure to sunlight and UV  
radiating sources.  
EXTERNAL HOUSE-SIDE SHIELD  
[MA1213-XX + MA1214-XX]  
WALL BRACKET [WM]  
Wall bracket secured to wall via four [4] lag  
bolts [lag bolts supplied by other]. Wall  
bracket kit includes 1/2" thick steel adapter  
plate, a 8" [TMU] or 10 1/2" [TLU] machined  
extruded aluminum arm and two [2] fixture  
support rods.  
QUARTZ RESTRIKE [Q + E]  
External house-side shield provides sharp  
cutoff behind the pole and shields the lamp  
from direct view. Mounted to the door frame  
via double-sided VHB adhesive [TMU] or three  
[3] stainless steel fasteners [TLU]. Rotatable in  
90° increments, the external house-side shield  
provides industry leading glare and spill light  
control.  
Optional quartz restrike [Q] energizes auxiliary  
quartz lamp upon power reactivation and  
extinguishes once HID lamp re-ignites.  
Quartz restrike with time delay [E] adds  
cold start activation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPTIONS  
[Factory installed and shipped complete with luminaire]  
Electrical  
1=Single Fuse [120, 277 or 347V]  
2=Double Fuse [208, 240 or 480V]  
3=3 Place Terminal Block  
4=NEMA Twistlock Photocontrol Receptacle  
E=Quartz Restrike w/Delay [Also Strikes at Cold Start]  
H=Plug-in Starter Receptacle  
HL=Hi/Low Dimming [Vertical Optics Only]  
P=Button Type Photocontrol [TMU Only]  
Q=Quartz Restrike [Hot Restrike Only]  
R=Removable Power Tray [Standard on TLU]  
U=U.L. Listed  
[4]  
[B]  
Shields + Doors  
B=Internal House Side Shield  
DD=Deep Door [TMU Only]  
V=Polycarbonate Vandal Shield [TMU Only]  
Mounting  
DM=Direct Mount for Round or Square Pole  
DW=Direct Wall Mount Kit  
MS=External Mast Arm Adapter [TMU Only]  
WM=Wall Bracket with Arm  
ACCESSORIES  
[Tenon Adapter]  
[Field installed and shipped independent of luminaire]  
Electrical  
OA/RA1016=NEMA Photocontrol [105-285V]  
OA/RA1027=NEMA Photocontrol [480V]  
OA/RA1201=NEMA Photocontrol [347V]  
OA/RA1013=Shorting Cap  
Tenon Adapters  
MA1010-XX=Single Tenon Adapter for 3 1/2" O.D. Tenon  
MA1011-XX=2 @ 180° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1012-XX=3 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1013-XX=4 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1014-XX=2 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1015-XX=2 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1016-XX=3 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1017-XX=Single Tenon Adapter for 2 3/8" O.D. Tenon  
MA1018-XX=2 @ 180° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1019-XX=3 @ 120° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1045-XX=4 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1048-XX=2 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1049-XX=3 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
[V]  
[MA1213 + MA1214]  
Shields  
MA1213-XX=External House-side Shield Kit [TMU Only]  
MA1214-XX=External House-side Shield Kit [TLU Only]  
[Q + E]  
DEEP DOOR [DD]  
Medium housing vertically lamped optics are  
shipped standard with Deep Door. For sites  
combining horizontal and vertical optics, specify  
the Deep Door [DD] option on horizontal lamp  
fixtures to maintain a uniform outward aesthetic.  
Reflector shifted downward toward the lens to  
maintain optimal photometric performance  
[TMU only].  
Horizontal optic in deep door position.  
Horizontal optic in recessed door position.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
16  
PHOTOMETRICS [Complete IES files available at www.cooperlighting.com]  
FOOTCANDLE TABLE  
Select mounting height and read across for  
footcandle values of each isofootcandle  
line. Distance in units of mounting height.  
Mounting Footcandle Values for  
Height  
Isofootcandle Lines  
A
B
C
D
E
A
B C D  
E
A
B
C
D
A
B
C D  
A
B
C
D
100W [3F]  
15'  
20'  
25'  
3.40 1.70 0.86  
2.00 1.00 0.50  
1.28 0.64 0.32  
0.34  
0.20  
0.13  
0.17  
0.10  
0.06  
150W [4V]/175W [3V/AS]  
15'  
20'  
25'  
1.70 0.85 0.34  
1.00 0.50 0.20  
0.64 0.32 0.13  
0.17  
0.10  
0.06  
--  
--  
--  
TMU10SXX3FF  
100-Watt HPS  
TMU15SXX4VS  
150-Watt HPS  
TMU17MXX3VF  
TMU17MXXASF  
175-Watt MH  
175-Watt MH  
9,500-Lumen Clear Lamp  
Type III Formed  
Flat Glass  
16,000-Lumen Clear Lamp  
Type IV Vertical  
Sag Glass  
14,000-Lumen Clear Lamp  
Type III Vertical  
14,000-Lumen Clear Lamp  
Area Square  
Flat Glass  
Flat Glass  
FOOTCANDLE TABLE  
Select mounting height and read across for  
footcandle values of each isofootcandle  
line. Distance in units of mounting height.  
Mounting Footcandle Values for  
Height  
Isofootcandle Lines  
A
B
C
D
E
A B C DE  
A
B
C
D
A
B C  
D
E
A
B
C D E  
250W [5F/SL]/400W [3S]  
25'  
30'  
35'  
2.88 1.44 0.72  
2.00 1.00 0.50  
1.46 0.73 0.37  
0.29  
0.20  
0.15  
0.14  
0.10  
0.07  
250W [AS]  
25'  
30'  
35'  
1.44 0.72 0.29  
0.14  
0.10  
0.07  
--  
--  
--  
1.00 0.50 0.20  
0.73 0.37 0.15  
TMU25SXX5FF  
250-Watt HPS  
TMU25SXXASS  
TMU25MXXSLF  
TMU40MXX3SF  
250-Watt HPS  
250-Watt MH  
400-Watt MH  
30,000-Lumen Clear Lamp  
Type V Formed  
Flat Glass  
30,000-Lumen Clear Lamp  
Area Square  
20,500-Lumen Clear Lamp  
Spill Light Eliminator  
Flat Glass  
36,000-Lumen Clear Lamp  
Type III Segmented  
Flat Glass  
Sag Glass  
FOOTCANDLE TABLE  
Select mounting height and read across for  
footcandle values of each isofootcandle  
line. Distance in units of mounting height.  
Mounting Footcandle Values for  
Height  
Isofootcandle Lines  
A
B
C
D
E
A
B
C
D
E
A
B
C
D E  
A
B
C D E  
A
B
C
D
E
400W [3V/4V/5S/AR]  
20'  
25'  
30'  
3.00 1.50 0.75  
2.00 1.00 0.50  
1.38 0.69 0.34  
0.30  
0.20  
0.13  
0.15  
0.10  
0.06  
TMU40MXX3VS  
TMU40MXX4VS  
400-Watt MH  
TMU40MXX5SF  
400-Watt MH  
TMU40MXXARF  
400-Watt MH  
400-Watt MH  
36,000-Lumen Clear Lamp  
Type III Vertical  
36,000-Lumen Clear Lamp  
Type IV Vertical  
Sag Glass  
36,000-Lumen Clear Lamp  
Type V Segmented  
Flat Glass  
36,000-Lumen Clear Lamp  
Area Round  
Sag Glass  
Flat Glass  
FOOTCANDLE TABLE  
Select mounting height and read across for  
footcandle values of each isofootcandle  
line. Distance in units of mounting height.  
Mounting Footcandle Values for  
Height  
Isofootcandle Lines  
A
B
C
D
E
A
BCDE  
A
B
C
D
E
A
B C DE  
A
B
C
D
E
400W [2F/3VB/5F/AR]  
25'  
30'  
35'  
2.88 1.44 0.72  
2.00 1.00 0.50  
1.46 0.73 0.37  
0.29  
0.20  
0.15  
0.14  
0.10  
0.07  
TMU40SXX2FF  
400-Watt HPS  
TMU40SXX3VSB  
TMU40SXX5FF  
400-Watt HPS  
TMU40SXXARS  
400-Watt HPS  
400-Watt HPS  
50,000-Lumen Clear Lamp  
Type II Formed  
Flat Glass  
50,000-Lumen Clear Lamp  
Type III Vertical Sag Glass  
Internal House-side Shield  
50,000-Lumen Clear Lamp  
Type V Formed  
Flat Glass  
50,000-Lumen Clear Lamp  
Area Round  
Sag Glass  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PHOTOMETRICS [Complete IES files available at www.cooperlighting.com]  
FOOTCANDLE TABLE  
Select mounting height and read across for  
footcandle values of each isofootcandle  
line. Distance in units of mounting height.  
Mounting Footcandle Values for  
Height  
Isofootcandle Lines  
A
B
C
D
E
A B  
C
D E  
A B C D E  
A B C D E  
A
B
C
D
400W [3F/4F/3V]  
25'  
30'  
35'  
2.88 1.44 0.72  
2.00 1.00 0.50  
1.46 0.73 0.37  
0.29  
0.20  
0.15  
0.14  
0.10  
0.07  
400W [AR]  
25'  
30'  
35'  
1.44 0.72 0.29  
0.14  
0.10  
0.07  
--  
--  
--  
1.00 0.50 0.20  
0.73 0.37 0.15  
TLU40SXX3VF  
TLU40MXX3FF  
400-Watt MH  
TLU40SXX4FF  
TLU40MXXARS  
400-Watt HPS  
400-Watt HPS  
400-Watt MH  
50,000-Lumen Clear Lamp  
Type III Vertical  
Flat Glass  
36,000-Lumen Clear Lamp  
Type III Formed  
Flat Glass  
50,000-Lumen Clear Lamp  
Type IV Formed  
Flat Glass  
36,000-Lumen Clear Lamp  
Area Round  
Sag Glass  
FOOTCANDLE TABLE  
Select mounting height and read across for  
footcandle values of each isofootcandle  
line. Distance in units of mounting height.  
Mounting Footcandle Values for  
Height  
Isofootcandle Lines  
A
B
C
D
E
A
B
C D E  
A B C D E  
A B C D E  
A
B C D  
E
400W [AR]/1000W [3F]  
25'  
30'  
35'  
2.88 1.44 0.72  
2.00 1.00 0.50  
1.46 0.73 0.37  
0.29  
0.20  
0.15  
0.14  
0.10  
0.07  
1000W [SL/3V]  
25'  
30'  
35'  
7.20 2.88 1.44  
0.72  
0.50  
0.37  
0.29  
0.20  
0.15  
5.00 2.00 1.00  
3.65 1.46 0.73  
TLU40SXXARF  
400-Watt HPS  
TLU40SXXSLF  
TLU91SXX3FF  
TLU91MXX3VF  
400-Watt HPS  
1000-Watt HPS  
135,000-Lumen Clear Lamp  
Type III Formed  
Flat Glass  
1000-Watt MH  
50,000-Lumen Clear Lamp  
Area Round  
50,000-Lumen Clear Lamp  
Spill Light Eliminator  
Flat Glass  
110,000-Lumen Clear Lamp  
Type III Vertical  
Flat Glass  
Flat Glass  
FOOTCANDLE TABLE  
Select mounting height and read across for  
footcandle values of each isofootcandle  
line. Distance in units of mounting height.  
Mounting Footcandle Values for  
Height  
Isofootcandle Lines  
A
B
C
D
E
A B C D F  
A B C DE  
A BC DF  
A
B C D  
E
1000W [3V-EHS (HPS)/5F]  
25'  
30'  
35'  
2.88 1.44 0.72  
2.00 1.00 0.50  
1.46 0.73 0.37  
0.29  
0.20  
0.15  
0.14  
0.10  
0.07  
1000W [3V-EHS (MH)/4VB]  
25'  
30'  
35'  
7.20 2.88 1.44  
5.00 2.00 1.00  
3.65 1.46 0.73  
0.72  
0.50  
0.37  
0.29  
0.20  
0.15  
TLU91MXX3VFEHS  
TLU91SXX3VFEHS  
TLU91MXX4VFB  
TLU91SXX5FF  
1000-Watt MH  
1000-Watt HPS  
1000-Watt MH  
1000-Watt HPS  
135,000-Lumen Clear Lamp  
Type V Formed  
Flat Glass  
110,000-Lumen Clear Lamp  
Type III Vertical Flat Glass  
External House-side Shield  
135,000-Lumen Clear Lamp  
Type III Vertical Flat Glass  
External House-side Shield  
110,000-Lumen Clear Lamp  
Type IV Vertical Flat Glass  
House-side Shield  
FOOTCANDLE TABLE  
Select mounting height and read across for  
footcandle values of each isofootcandle  
line. Distance in units of mounting height.  
Mounting Footcandle Values for  
Height  
Isofootcandle Lines  
A
B
C
D
E
A B C D E  
A B C D E  
A
B
C
D
E
A B C  
D
E
1000W [4V/SL/AS]  
25'  
30'  
35'  
2.88 1.44 0.72  
2.00 1.00 0.50  
1.46 0.73 0.37  
0.29  
0.20  
0.15  
0.14  
0.10  
0.07  
1000W [AF]  
25'  
27'  
30'  
30.00 10.00 3.00  
1.00  
0.85  
0.69  
0.20  
0.17  
0.14  
25.50 8.50 2.55  
20.70 6.90 2.07  
TLU91SXX4VFB  
TLU91MXXSLF  
TLU91MXXASF  
1000-Watt MH  
110,000-Lumen Clear Lamp  
Area Square  
TLU91MXXAFF  
1000-Watt HPS  
1000-Watt MH  
1000-Watt MH  
135,000-Lumen Clear Lamp  
Type IV Vertical Flat Glass  
Internal House-side Shield  
110,000-Lumen Clear Lamp  
Spill Light Eliminator  
Flat Glass  
110,000-Lumen Clear Lamp  
Automotive Front Row  
Flat Glass  
Flat Glass  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
18  
TMU TALON MEDIUM  
ORDERING INFORMATION  
SAMPLE NUMBER: TMU40SWW3SF  
LAMP TYPE  
BALLAST TYPE  
VOLTAGE  
2=120V  
0=208V  
4=240V  
DISTRIBUTION  
LENS TYPE  
COLOR  
OPTIONS +  
ACCESSORIES  
[See Below]  
PRODUCT  
LAMP  
1
2
S=High  
C=CWI  
Horizontal Lamp  
F=Flat Glass [add as suffix  
S=Sag Glass /must specify]  
WH=White  
FAMILY  
WATTAGE  
70=70W  
10=100W  
Pressure  
H=Reac./HPF  
K=10KV CWA  
2F=Type II Formed  
2S=Type II Segmented  
3F=Type III Formed  
3S=Type III Segmented  
4F=Type IV Formed  
4S=Type IV Segmented  
TMU=Talon  
Sodium  
Site  
R=Super Metal  
N=Hi. Reac./NPF 7=277V  
P=Hi. Reac./HPF 8=480V  
BK=Black  
Medium 15=150W  
Halide  
AP=Grey  
17=175W  
M=Metal  
Halide  
R=Reac./NPF  
W=CWA  
9=347V  
BZ=Bronze  
20=200W  
25=250W  
N=Multi-Tap  
DP=Dark Platinum  
3, 4  
3, 4  
4
P=Pulse Start  
Metal Halide  
wired 277V 5F=Type V Formed  
GM=Graphite Metallic  
32=320W  
35=350W  
W=Multi-Tap  
wired 120V SL=Spill Light Eliminator  
V=Multi-Tap AF=Automotive Front Row  
5S=Type V Segmented  
40=400W  
24=250/400W  
wired 250W  
wired 240V Vertical Lamp  
5
5
42=250/400W  
wired 400W  
3V=Type III Vertical  
4V=Type IV Vertical  
5
5
AR=Area Round  
AS=Area Square  
OPTIONS + ACCESSORIES [must be ordered in alphanumeric order]  
OPTIONS [add as suffix]  
ACCESSORIES [order separately/replace XX with color designation]  
6
1=Single Fuse [120, 277 or 347V]  
OA/RA1016=NEMA Photocontrol [105-285V]  
6
2=Double Fuse [208, 240 or 480V]  
OA/RA1027=NEMA Photocontrol [480V]  
3=Three Place Terminal Block  
OA/RA1201=NEMA Photocontrol [347V]  
4=NEMA Twistlock Photocontrol Receptacle  
OA/RA1013=Shorting Cap  
7
B=Internal House-side Shield  
MA1010-XX=Single Tenon Adapter for 3 1/2" O.D. Tenon  
MA1011-XX=2 @ 180° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1012-XX=3 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1013-XX=4 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1014-XX=2 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1015-XX=2 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1016-XX=3 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1017-XX=Single Tenon Adapter for 2 3/8" O.D. Tenon  
MA1018-XX=2 @ 180° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1019-XX=3 @ 120° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1045-XX=4 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1048-XX=2 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1049-XX=3 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1213-XX=External House-side Shield Kit [EPA=0.38]  
DD=Deep Door  
DM=Direct Mount for Round or Square Pole  
DW=Direct Wall Mount Kit  
8
E=Quartz Restrike w/Delay [Also Strikes at Cold Start]  
H=Plug-in Starter Receptacle  
9
HL=Hi/Low Dimming  
L=Lamp Included  
MS=External Mast Arm Adapter  
6
P=Button Type Photocontrol [120, 208, 240 or 277V]  
8
Q=Quartz Restrike [Hot Restrike Only]  
R=Removable Power Tray  
U=U.L. Listed  
V=Polycarbonate Vandal Shield  
WM=Wall Bracket with 8" Arm  
DIMENSIONS  
DRILLING PATTERNS  
TYPE “M”  
WALL MOUNT  
8"  
2 5/16"  
[59mm]  
[203mm]  
12"  
[305mm]  
11 7/8"  
3/4" [20mm]  
dia. hole  
2 7/16" [124mm]  
[302mm]  
4 7/8"  
[124mm]  
10 1/2"  
[267mm]  
4 7/8" [124mm]  
23 1/4" [590mm]  
8"  
1 3/4"  
[45mm]  
[203mm]  
[2] 5/8" [16mm]  
dia. holes  
6 1/2"  
[165mm]  
8"  
9/16" [14mm]  
Dia. Hole [4]  
16 1/4" [412mm]  
[203mm]  
EPA  
CERTIFICATIONS  
WATTAGE TABLE  
Effective Projected Area  
IP65 Rated  
CSA Listed  
ISO 9001  
Lamp Type  
Metal Halide  
Wattage  
175, 250, 400W  
Recessed Door w/o Arm: 0.79  
25° C Ambient Temperature  
U.L. 1598 Listed  
Deep Door w/o Arm:  
8" Arm:  
1.02  
0.43  
FCO [Full Cutoff] Flat Glass Only  
Pulse Start Metal Halide 70, 100, 150, 175, 200, 250, 320, 350, 400W  
Super Metal Halide  
High Pressure Sodium  
175, 250, 400W  
70, 100, 150, 250, 400W  
SHIPPING DATA  
Approximate Net Weight  
STANDARD COLORS  
Recessed Door 47 lbs. [21.79 kgs.]  
Deep Door  
52 lbs. [23.63 kgs.]  
BK  
WH  
AP  
BZ  
DP  
Dark Platinum  
GM  
Black  
White  
Grey  
Bronze  
Graphite Metallic  
NOTES: 1 8" arm and round pole adapter included with fixture. 2 Standard with mogul-base socket for HPS and 100-400W MH. Standard with medium-base socket for 70W MH. 3 320/350W Pulse Start Metal Halide  
lamp only. 4 Requires reduced envelope lamp. 5 Vertical lamp optics ship standard with deep door. Flat glass not available for 250W—400W. 6 Must specify voltage. 7 House-side shield not available on 5S,  
5F, AS, AR and SL optics. 8 Quartz options not available with SL and AF optics. 9 Requires vertical lamp orientation. Provides 24V low voltage leads used in dimming controls. 10 Specifications and  
dimensions subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TLU TALON LARGE  
ORDERING INFORMATION  
SAMPLE NUMBER: TLU91SWW3VF  
LAMP TYPE  
S=High  
BALLAST TYPE  
C=CWI  
VOLTAGE  
2=120V  
0=208V  
4=240V  
7=277V  
DISTRIBUTION  
LENS TYPE  
F=Flat Glass  
S=Sag Glass  
COLOR  
OPTIONS +  
ACCESSORIES  
[See Below]  
PRODUCT LAMP  
1
FAMILY  
WATTAGE  
Horizontal Lamp  
2F=Type II Formed  
2S=Type II Segmented  
3F=Type III Formed  
[add as suffix  
/must specify]  
WH=White  
BK=Black  
Pressure  
H=Reac./HPF  
K=10KV CWA  
M=Mag. Reg.  
TLU=Talon 25=250W  
2
2
4
Sodium  
R=Super Metal  
Halide  
Site  
32=320W  
Large 35=350W  
4
4
40=400W  
N=Hi. Reac./NPF 8=480V  
P=Hi. Reac./HPF 9=347V  
3S=Type III Segmented  
4F=Type IV Formed  
AP=Grey  
M=Metal  
BZ=Bronze  
75=750W  
2
Halide  
R=Reac./NPF  
W=CWA  
N=Multi-Tap  
4S=Type IV Segmented  
DP=Dark Platinum  
87=875W  
3
P=Pulse Start  
wired 277V 5F=Type V Formed  
GM=Graphite Metallic  
91=1000W  
4
Metal Halide  
W=Multi-Tap  
5S=Type V Segmented  
3
wired 120V SL=Spill Light Eliminator  
V=Multi-Tap  
Vertical Lamp  
wired 240V 3V=Type III Vertical  
4V=Type IV Vertical  
AR=Area Round  
AS=Area Square  
AF=Automotive Front Row  
OPTIONS + ACCESSORIES [must be ordered in alphanumeric order]  
OPTIONS [add as suffix]  
ACCESSORIES [order separately/replace XX with color designation]  
OA/RA1016=NEMA Photocontrol [105-285V]  
5
1=Single Fuse [120, 277 or 347V]  
5
2=Double Fuse [208, 240 or 480V]  
OA/RA1027=NEMA Photocontrol [480V]  
3=Three Place Terminal Block  
OA/RA1201=NEMA Photocontrol [347V]  
4=NEMA Twistlock Photocontrol Receptacle  
OA/RA1013=Shorting Cap  
6
B=Internal House-side Shield  
MA1010-XX=Single Tenon Adapter for 3 1/2" O.D. Tenon  
MA1011-XX=2 @ 180° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1012-XX=3 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1013-XX=4 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1014-XX=2 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1015-XX=2 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1016-XX=3 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon  
MA1017-XX=Single Tenon Adapter for 2 3/8" O.D. Tenon  
MA1018-XX=2 @ 180° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1019-XX=3 @ 120° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1045-XX=4 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1048-XX=2 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1049-XX=3 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon  
MA1214-XX=External House-side Shield Kit [EPA=0.94]  
DM=Direct Mount for Pole  
7
E=Quartz Restrike w/Delay [Also Strikes at Cold Start]  
8
H=Plug-in Starter Receptacle  
9
HL=Hi/Low Dimming  
L=Lamp Included  
7
Q=Quartz Restrike [Hot Restrike Only]  
U=U.L. Listed  
WM=Wall Bracket with 10 1/2" Arm  
DIMENSIONS  
DRILLING PATTERNS  
TYPE “M”  
WALL MOUNT  
2 5/16"  
[59mm]  
14 1/8"  
[359mm]  
12"  
[305mm]  
3/4" [20mm]  
dia. hole  
2 7/16" [124mm]  
4 7/8"  
[124mm]  
10 1/2"  
[267mm]  
4 7/8" [124mm]  
31" [787mm]  
10 1/2"  
[267mm]  
3 1/8"  
[79mm]  
[2] 5/8" [16mm]  
dia. holes  
6 1/2"  
[165mm]  
8"  
9/16" [14mm]  
Dia. Hole [4]  
21 5/8" [549mm]  
[203mm]  
EPA  
CERTIFICATIONS  
WATTAGE TABLE  
Effective Projected Area  
Without Arm:  
IP65 Rated  
CSA Listed  
ISO 9001  
Lamp Type  
Metal Halide  
Wattage  
250, 400, 1000W  
1.82  
0.6  
25° C Ambient Temperature  
U.L. 1598 Listed  
10 1/2" Arm:  
FCO [Full Cutoff] Flat Glass Only  
Pulse Start Metal Halide  
Super Metal Halide  
High Pressure Sodium  
250, 320, 350, 400, 450, 750, 875, 1000W  
250, 400, 750, 1000W  
SHIPPING DATA  
Approximate Net Weight  
250, 400, 1000W  
STANDARD COLORS  
400W  
91 lbs. [41.36 kgs.]  
1000W  
98 lbs. [44.54 kgs.]  
BK  
WH  
White  
AP  
BZ  
DP  
GM  
Black  
Grey  
Bronze  
Dark Platinum  
Graphite Metallic  
NOTES: 1 10 1/2" arm and round pole adapter included with fixture. 2 320/350/875W Pulse Start Metal Halide lamp only. 3 Requires reduced envelope lamp. 4 Maximum wattage on segmented optical  
distributions is 400W. 400W Metal Halide lamp must use reduced envelope ED-28 lamp. 5 Must Specify Voltage. 6 House-side shield not available on 5S, 5F, AS, AR and SL optics. 7 Quartz options not  
available with SL and AF optics. 8 Not available in 1000W. 9 Requires vertical lamp orientation. Provides 24V low voltage leads used in dimming control. 10 Specifications and dimensions subject to change  
without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cooper Lighting  
International Sales, USA  
Cooper Lighting  
1121 Highway 74 South  
Peachtree City, GA 30269  
The Cooper Lighting Family  
Halo  
Customer First Center  
1121 Highway 74 South  
Peachtree City, GA 30269  
Metalux  
Lumark  
Sure-Lites  
Neo-Ray  
Corelite  
Portfolio  
Iris  
P: 770-486-4800  
F: 770-486-4801  
P: 770-486-4800  
F: 770-486-4801  
Canada  
Cooper Lighting  
5925 McLaughlin Road  
Mississauga, Ontario L5R 1B8  
Shaper  
io  
Lumière  
Invue  
P: 905-507-4000  
F: 905-568-7049  
McGraw-Edison  
Streetworks  
Fail-Safe  
MWS  
DLS  
RSA  
Ametrix  
Domestic Facilities  
Cranbury, New Jersey  
Elk Grove Village, Illinois  
Irving, Texas  
Canadian Facility  
Calgary, Alberta T2E 7V9  
Ontario, California  
Peachtree City, Georgia  
Cooper Lighting, Streetworks, Talon and Accel Optics are valuable trademarks of Cooper Industries in the United States and other countries.  
You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.  
Cooper Industries, Ltd.  
600 Travis, Ste. 5800  
Houston, TX 77002-1001  
P: 713-209-8400  
ADW080322  
Printed in USA  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cooper Lighting Indoor Furnishings 17 IP User Manual
Craftsman Lawn Mower 38905 User Manual
Creative Labs Computer Accessories CB2431 User Manual
Dixon Lawn Mower 14186 0303 User Manual
Duracell Battery Charger Ultra 245 User Manual
Edelbrock Camera Accessories 4779 User Manual
EVGA Computer Hardware GTX 295 User Manual
Fisher Price Riding Toy M6784 User Manual
Frigidaire Air Conditioner FRS22PYC21 User Manual
Gateway Computer Monitor FPD2185W User Manual