Casio Watch HS 70W User Manual

MA0809-EA  
HS-70W  
LAP/SPLIT TIMES  
CHART  
ENGLISH  
START  
1ST LAP  
STOP  
RESET  
2ND LAP  
3RD LAP  
Time Display  
Stopwatch Display  
0
(a)  
(a + b) (a + b + c)  
(t)  
a
b
c
Day of the week  
(
)
a
1ST SPLIT  
Lap counter  
Split time  
(
)
2ND SPLIT a+b  
3RD SPLIT a+b+c  
(
)
Year  
BUTTON  
Month  
Day  
Lap time  
OPERATION  
PM  
Total  
elapsed time  
Second  
Minute  
DISPLAY  
Hour  
Hours  
Seconds  
Minutes  
1/1000th of a second  
MULTIPLE FINISHING TIMES  
Example : To record the times of 100 different runners.  
Timekeeping Mode  
Stopwatch Mode  
Recall Mode  
START  
1ST  
RUNNER  
FINISHES  
2ND  
RUNNER  
FINISHES  
99TH  
RUNNER  
FINISHES  
100TH  
RUNNER  
FINISHES  
RESET  
Press  
.
Press  
.
CHART  
A sticker is affixed to the glass of this stopwatch when you purchase it. Be sure to remove the sticker before using  
the stopwatch.  
BUTTON  
OPERATION  
Depending on its model, the configuration of your stopwatch may differ somewhat from that shown in the  
illustration.  
Difference between current finisher  
and previous finisher  
OPERATING PRECAUTIONS  
A battery is installed at the factory. Have it replaced by a CASIO distributor at the first sign of low power (dim  
DISPLAY  
display).  
Do not use or store this stopwatch in areas exposed to temperature extremes, strong magnetism, strong  
vibration, or strong impact.  
Heat can shorten battery life and cause malfunction. Keep the stopwatch away from heaters and direct sunlight  
when using it.  
Finishing position  
Never try to take the stopwatch apart. Doing so can cause malfunction.  
To clean the stopwatch, use a soft, dry cloth or a cloth moistened in a solution of water and a mild neutral  
detergent. Wring out all excess moisture from the cloth. Never use thinner, benzene, alcohol or other similar  
agents.  
USING THE RECALL MODE  
You can use the recall mode to view data in stopwatch memory.  
Be sure to keep all user documentation handy for future reference.  
There is enough memory to store a total of up to 200 records, divided between two record groups of 100 each. If  
you record 100 times, the 100th time will not be stored in memory until you reset the stopwatch to all zeros.  
Starting a new stopwatch elapsed time operation will cause the older of the two record groups to be deleted  
automatically in order to make room for a new group of records.  
There is also a FAST LAP record that displays the fastest lap from among all of the lap times currently in memory.  
Record 1 (the newest record) will always be displayed first whenever you press the R button to switch from the  
Stopwatch Mode to the Recall Mode.  
CASIO COMPUTER CO., LTD. assumes no responsibility for any loss, or any claims by third parties that may  
arise through the use of this stopwatch.  
GENERAL GUIDE  
C button .... Starts and stops timing.  
B button .... Toggles between the current time and stopwatch screens.  
A button ..... Performs lap/split and reset operation (stopwatch beeps).  
R button ..... Recalls lap/split time records and total elapsed time.  
In the Recall Mode, each press of the B button will toggle the display between record group 1 and record group 2.  
Lap time records in memory can be recalled while an elapsed time operation is in progress or stopped.  
Memory records are cleared whenever a new Stopwatch Mode elapsed time operation is stared by pressing the  
C button after pressing the A button to reset the stopwatch to all zeros.  
Holding down the  
or  
button scrolls at high speed.  
1ST SPLIT  
SPLIT TIME AND LAP TIME  
2ND SPLIT  
2ND LAP  
3RD SPLIT  
3RD LAP  
Split time (SPLIT) is the time  
elapsed from the start to a  
specific point.  
START  
START  
1ST LAP  
Lap time (LAP) is the time  
elapsed from one point to another  
or for one lap around a track.  
SETTING THE CURRENT TIME AND DATE  
1. In the Timekeeping Mode, hold down R for about two seconds.  
MUTE  
2. Press C on a time signal to correct the seconds.  
3. Flashing setting can be changed. Press B to move the flashing.  
USING THE STOPWATCH  
The stopwatch beeps to signal C and A button operations.  
SECONDS  
HOUR  
DAY  
MINUTES  
MONTH  
YEAR  
Working range  
The total elapsed time and split time display is limited to 9 hours 59 minutes 59.999 seconds. Lap time display is  
limited to 59 minutes 59.999 seconds.  
4. Use C (+) and A (–) to change the flashing setting.  
Holding down the C or A button scrolls at high speed.  
5. Press R to exit the setting mode.  
Thereafter it will be reset and started again. The lap counter starts from 1 to 99 and repeats from 0.  
While the stopwatch is reset to all zeros, holding down the A button will toggle the lower display area between  
display of lap time and split time.  
* Year digits can be set up to the year 2099.  
100 (indicating the number of laps) will flash on the display when memory is full (100 lap times in the current  
group).  
12/24-hour Timekeeping  
In the Timekeeping Mode, press C to toggle between 12-hour and 24-hour  
NORMAL TIME  
timekeeping.  
START  
0
STOP  
(a)  
RESET  
Beeper On/Off  
In the Timekeeping Mode, hold down the A button for about two seconds to toggle the beeper on or off.  
CHART  
a
Auto Return  
The stopwatch returns to the Timekeeping Mode if left unused for a few minutes.  
BUTTON  
OPERATION  
CARE OF YOUR STOPWATCH  
This stopwatch is water resistant up to five bars (atmospheres), which means you can use it in the rain or in  
areas where splashing water is present.  
Never, however, operate the buttons of the stopwatch while it is immersed in water.  
You should have the rubber seal that keeps out water and dust replaced every 2 to 3 years.  
Should moisture appear inside the stopwatch, have it checked immediately by your dealer or a CASIO distributor.  
DISPLAY  
SPECIFICATIONS  
NET TIME  
CHART  
Accuracy at a normal temperature (TIME): 30 seconds per month  
(STOPWATCH): 99.9988%  
Display capacity:  
Time Display: Hour, minutes, seconds, am/pm, year, month, day and day of the week  
Calendar system: Pre-programmed until the year 2099  
Stopwatch Display:  
Measuring capacity: (Total elapsed time display) 9 hours 59 minutes 59.999 seconds  
(Lap time display) 59 minutes 59.999 seconds  
(Split time display) 9 hours 59 minutes 59.999 seconds  
Measuring unit: 1/1000 second  
Measuring modes: Net time, lap time, split time, 1st-100th place time, lap counter (up to 99)  
Memory capacity: 2 sets of 100 records each  
START  
0
STOP  
(a)  
START  
(a)  
STOP  
(a + b)  
RESET  
a
b
(Stoppage time)  
BUTTON  
OPERATION  
DISPLAY  
Battery: One lithium battery (type: CR2032)  
Approx. 5 years continuous operation on type CR2032  
(includes an average of 30 presses of button per day.)  
After stopping a net time operation by pressing C, you can resume it by pressing C again.  
Download from Www.Somanuals.com. AOllpMeraatninugaTlesmSpeeraartucrhe:A0°nCdtoD4o0°wCn(3lo2°aFdto. 104°F)  

Beyond TV DVD Combo FlipScreen User Manual
Billy Goat Lawn Mower SC121H User Manual
Black Decker Vacuum Cleaner CHV1410L User Manual
Blodgett Oven B48A CCCC User Manual
Califone Computer Monitor KIDSPACK User Manual
Canon Camera Flash 270EX II User Manual
Canon Scanner LIDE 80 User Manual
Casio Camcorder EX ZR1000 User Manual
Cerwin Vega Speaker Stoker Pro User Manual
Channel Vision Network Card IR 2005 User Manual