Agilent Technologies Network Router N9360A User Manual

Agilent N9360A  
Multi UE Tester  
Quick Reference Guide  
Agilent Technologies  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Thank-you for purchasing the Agilent N9360A mobile communciations  
tester.  
Before using the tester, the user is advised to read this manual  
carefully to ensure correct usage and also to fully utilize the tester  
capability.  
This manual is a reference document and the user is advised to keep it  
carefully for future reference.  
The manual includes the the tester operation, test procedures and  
screen references.  
Refer to the N9360A Multi UE Tester Installation Guide for information  
regarding installation and details of the tester. Refer also to the  
N9360A W-CDMA Option User Manual and N9360A cdma2000 Option  
User Manual for information about the test functions of the Wideband  
Code Division Multiple Access (W-CDMA), and Code Division Multiple  
Access (cdma2000).  
Notation  
Notices  
The following notations are used in this manual:  
Softkey: indicates a softkey;  
[Screen Name]: indicates a screen name;  
Tester/tester : indicates the N9360A Multi UE Tester.  
The information contained in this manual is subjected to change with  
notice.  
No part of this manual may be reproduced either mechanically,  
electronically or otherwise, without permission from Agilent  
Technologies, Inc.  
Trademarks  
Ethernet is the registered trademark of the Xerox Corporation.  
EPSON is the registered trademark of the EPSON Corporation.  
Other product names and companies used herein are trademarks or  
registered trademarks of their respective companies or Agilent  
Technologies, Inc. For registered trademarks, the trademarks symbols  
® and ™ are omitted in this manual.  
cdma2000 is a registered trademark of Telecommunication Industry  
Association (TIA-USA).  
N9360A Multi UE Tester Quick Reference Guide  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
THIS PAGE IS INTENTIONALLY LEFT BLANK.  
iv  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Legal Information  
1-1  
Agilent Technologies  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1
Legal Information  
Legal Information  
Warranty  
The material contained in this document is provided “as is,” and  
is subject to being changed, without notice, in future editions.  
Further, to the maximum extent permitted by applicable law,  
Agilent disclaims all warranties, either express or implied, with  
regard to this manual and any information contained herein,  
including but not limited to the implied warranties of  
merchantability and fitness for a particular purpose. Agilent  
shall not be liable for errors or for incidental or consequential  
damages in connection with the furnishing, use, or performance  
of this document or of any information contained herein.  
Should Agilent and the user have a separate written agreement  
with warranty terms covering the material in this document  
that conflict with these terms, the warranty terms in the  
separate agreement shall control.  
Technology Licenses  
The hardware and/or software described in this document are  
furnished under a license and may be used or copied only in  
accordance with the terms of such license.  
Restricted Rights Legend  
If software is for use in the performance of a U.S. Government  
prime contract or subcontract, Software is delivered and  
licensed as “Commercial computer software” as defined in  
DFAR 252.227-7014 (June 1995), or as a “commercial item” as  
defined in FAR 2.101(a) or as “Restricted computer software” as  
defined in FAR 52.227-19 (June 1987) or any equivalent agency  
regulation or contract clause. Use, duplication or disclosure of  
Software is subject to Agilent Technologies’ standard  
commercial license terms, and non-DOD Departments and  
Agencies of the U.S. Government will receive no greater than  
Restricted Rights as defined in FAR 52.227-19(c)(1-2)(June  
1987). U.S. Government users will receive no greater than  
Limited Rights as defined in FAR 52.227-14 (June 1987) or  
DFAR 252.227-7015 (b)(2)(November 1995), as applicable in any  
technical data.  
1-2  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Legal Information  
1
Service And Support  
Any adjustment, maintenance, or repair of this product must be  
performed by qualified personnel. Contact your customer  
engineer through your local Agilent Technologies Service  
Center.  
Agilent On The Web  
You can find information about technical and professional  
services, product support, and equipment repair and service on  
Double-click the link to Test & Measurement. Select your country  
from the drop-down menus. The Web page that appears next has  
contact information specific for your country  
Agilent By Phone  
If you do not have access to the Internet, call one of the  
numbers in Table 1-1.  
Table 1-1 Agilent Call Centers and Regional Headquarters  
United States and Canada: Test and Measurement Call Center  
(800) 452 4844 (toll-free in US)  
Europe:  
(41 22) 780 8111  
Japan:  
Measurement Assistance Center  
(81) 0426 56 7832  
Latin America:  
Asia-Pacific:  
305 269 7548  
(85 22) 599 7777  
Manufacturing Address  
Agilent Technologies Microwave Products (Malaysia) Sdn. Bhd.  
Bayan Lepas Free Industrial Zone,  
11900 Penang,  
Malaysia.  
N9360A Multi UE Tester Quick Reference Guide  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
1
Legal Information  
THIS PAGE IS INTENTIONALLY LEFT BLANK  
1-4  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
Caution and Safety Requirements  
2-1  
Agilent Technologies  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Caution and Safety Requirements  
Safety Information  
Safety Summary  
The following general safety precautions must be observed  
during all phases of operation of this instrument. Failure to  
comply with these precautions or with specific warnings  
elsewhere in this manual violates safety standards of design,  
manufacture, and intended use of the instrument. Agilent  
Technologies, Inc. assumes no liability for the customer's failure  
to comply with these requirements.  
Safety Notices  
A CAUTION notice denotes a hazard. It calls attention to an  
operating procedure, practice, or the like, that, if not correctly  
performed or adhered to, could result in damage to the product or  
loss of important data. Do not proceed beyond a CAUTION notice  
until the indicated conditions are fully understood and met.  
CAUTION  
A WARNING notice denotes a hazard. It calls attention to an  
operating procedure, practice, or the like that, if not correctly  
performed or adhered to, could result in personal injury or death.  
Do not proceed beyond a WARNING notice until the indicated  
conditions are fully understood and met.  
WARNING  
Warning Label  
A warning label is stuck on the front panel of the Tester.  
Do not remove, damage or modify the warning label.  
2-2  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Caution and Safety Requirements  
2
General  
The protection provided by the N9360A tester may be impaired if  
the tester is used in a manner not specified by Agilent or the  
instructions on the display are not followed.  
WARNING  
DO NOT INSTRUMENT COVERS. Operating personnel must not  
remove any instrument covers. Component replacement and  
internal adjustments must be made only by qualified service  
personnel. Products that appear damaged or defective should be  
made inoperative and secured against unintended operation until  
they can be repaired by a qualified service personnel.  
WARNING  
When Operating The Tester  
Make sure that the input signal level does not exceed the maximum  
level allowed. Tester failure may result otherwise.  
CAUTION  
Do not turn off the Line switch on the rear panel of the Tester while  
the LINE LED on the front panel of the Tester is lit in green.  
Otherwise, Tester failure may occur.  
CAUTION  
N9360A Multi UE Tester Quick Reference Guide  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
2
Caution and Safety Requirements  
THIS PAGE IS INTENTIONALLY LEFT BLANK.  
2-4  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
General Operation  
3-1  
Agilent Technologies  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
General Operation  
Using a USB memory device  
A USB memory device can be used to save and recall the test  
procedures, to update the firmware of the Tester, and to save  
screen images as image files.  
Saving and Recalling Test Procedures:  
All settings for Automatic Test, Manual Test, TX Analyzer,  
Signal Generator, and Configuration can be saved into a test  
procedure file.  
To save a test procedure or to recall a pre-defined test  
procedure, go to the [Configuration] screen, then the [File  
Management] screen.  
Updating the Firmware:  
To update firmware of the Tester, press the FW Update softkey to  
go to the [Firmware Update] screen on the [Configuration]  
screen obtained from the [Top Menu] screen. Refer to the  
“Firmware Update Screen” in the User's Guide for details.  
Saving a Screen Image:  
To enable this function, it is required to set the “Printer” input  
field on the [Configuration] screen to USB Memory. Then, to save  
a screen image into a USB memory device, press the Print Screen  
softkey. The file format is PNG (Portable Network Graphics).  
Using the Knob on the Front Panel  
1. Rotate the knob to place  
the cursor next to the input  
field where you want to  
change.  
2. Push the knob to select  
the field where you placed  
the cursor.  
3. Rotate the knob to  
change the value in the  
field.  
4. Push the knob to set the  
value.  
3-2  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
General Operation  
3
Preparation for Tests  
Figure 3-1 Typical Test Setup  
Connecting RF Signal:  
1 Connect the mobile phone to the Tester using the  
user-supplied RF Cable, optional Antenna Coupler, or  
optional Shield Case.  
2 On the [Loss] screen obtained from the [Initial],  
[Configuration] and [Configuration: Test Condition] screens,  
set the “Loss” field to Onand enter the appropriate loss  
values for each Radio System or Band in the “RF In” and “RF  
Out” fields depending on the RF connection.  
Connecting a Printer:  
Connect a printer to print a hardcopy of the test results if  
required.  
Inserting the TEST SIM for GSM mobile phone or TEST USIM for a  
W-CDMA mobile phone:  
Insert the Test SIM (Subscriber Identity Module) supplied by  
Agilent into the GSM mobile phone or the test USIM  
(Universal Subscriber Identity Module) supplied by Agilent  
into the W-CDMA mobile phone before performing any test.  
GSM/W-CDMA/cdma2000 Mobile Phone Repair Process  
N9360A Multi UE Tester Quick Reference Guide  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3
General Operation  
GSM/W-CDMA/cdma2000 Mobile Phone Repair Process  
Figure 3-2 Mobile Phone Repair Process  
A typical GSM, W-CDMA and cdma2000 mobile phone repair  
process at service centers is basically divided into two  
processes, Incoming Inspection and Mechanical & Module  
Repair. In each process, you can perform the following tests  
with the Agilent N9360A Multi UE Tester.  
Table 3-1 Mobile Phone Repair Function  
Process  
Test  
Agilent N9360A Multi UE  
Tester Function  
Incoming Inspection Go/No-Go Test  
Automatic Test  
Module Repair  
Pinpointing Failures  
Troubleshooting  
Adjustment  
Automatic Test  
Manual Test  
TX Analyzer, Signal Generator  
Automatic Test  
Final Test  
(Go/No-Go Test)  
3-4  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4
GSM System  
4-1  
Agilent Technologies  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
GSM System  
For Go/No-Go Testing  
Figure 4-1 [Automatic Test: Stand-by] Screen  
1 Press the Automatic Test softkey on the [Initial] screen in GSM  
system.  
2 Move the cursor to the “Procedure” field, and select a  
pre-defined test procedure.  
3 Press the Start softkey.  
4 Turn the mobile phone on. Wait for the completion of  
Location Update.  
5 Operate the mobile phone as instructed in the table below.  
Each test flow step is highlighted as it runs.  
6 After completing the test, check the results on the screen.  
7 To print the test results or to save them into a USB memory  
device, press the More (1 of 2) softkey and then the Print Screen  
softkey.  
4-2  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
GSM System  
4
Table 4-2 GSM Automatic test sequence  
Step  
Action needed  
Location Update  
MS Call  
Wait until the Location Update is complete.  
Dial an arbitrary number and press the Off Hook key  
on the mobile phone.  
Talk  
Talk to the mobile phone to judge its loop back sound  
quality and press the Pass or Fail softkey.  
RF Test  
Wait until the RF test is complete.  
MS Release  
BS Call  
Finish the call from the mobile phone.  
Respond to the call on the mobile phone.  
Wait until the call is finished from the Tester.  
BS Release  
For Pinpointing Failures  
Figure 4-2 [Automatic Test: Stand-by] Screen  
1 Perform the steps described in “For Go/No-Go Testing.”  
2 Press the Screen>> softkey to set screen mode to Detail or  
Value.  
N9360A Multi UE Tester Quick Reference Guide  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4
GSM System  
3 Rotate the knob to place the cursor in one of the Pass/Fail  
cells on the detail screen or test result cells on the value  
screen. Then, press the knob.  
4 One of the following measurement result screens is displayed  
according to your selection in step 3.  
To print the measurement results or to save them into a  
USB memory device, press the Print Screen softkey.  
In the graphical display, you can use the marker function  
to read data points by rotating the knob.  
The zoom function is available on the power ramp graph  
display by pressing the Zoom Off/On softkey.  
Peak TX  
Power  
Burst Timing  
Power Ramp  
Phase Error  
Frequency Error  
Sensitivity  
RX Quality  
RX Level  
Figure 4-3 Various [Automatic Test: Stand-by] Screens  
5 To display other measurement result screens or to finish  
analysis, press the Return softkey to display the previous  
screen.  
4-4  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GSM System  
4
For Troubleshooting  
Figure 4-4 [Manual Test (GSM): Stand-by] Screen  
1 Press the Manual Test softkey on the [Initial] screen.  
2 Move the cursor to the “Procedure” field and select a  
pre-defined test procedure.  
3 Turn the mobile phone on.  
4 Wait for the completion of Location Update.  
5 Press the BS Call softkey and respond to the call on the  
mobile phone when it is called. Or, dial an arbitrary number  
and press the Off Hook key on the mobile phone to start the  
MS Call.  
6 To start measurement while the left screen is displayed, refer  
to step 7. For detailed measurement at each measurement  
item, refer to step 8.  
N9360A Multi UE Tester Quick Reference Guide  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4
GSM System  
Peak TX Power/ Burst  
Timing/ Power Ramp  
Phase Error  
Frequency Error  
Sensitivity  
RX Quality  
RX Level  
Spectrum  
Monitor  
Figure 4-5 Various [Manual Test (GSM): Stand-by] Screens  
7 While “Connection” is highlighted in the test flow, press the  
Trigger softkey to start single measurement or the Trigger  
Sing/Cont softkey to start continuous measurement. Press the  
Trigger Sing/Cont softkey again to terminate the continuous  
measurement.  
8 Place the cursor at one of the groups of the test items and  
press the knob or press the Spectrum Monitor softkey to display  
a measurement result screen according to your selection.  
Then, press the Trigger softkey to start single measurement or  
Trigger Sing/Cont softkey to start continuous measurement.  
4-6  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GSM System  
4
Press the Trigger Sing/Cont softkey again to terminate the  
continuous measurement.  
9 In the graphical display, the marker function is available to  
read the data points by rotating the knob. On the power ramp  
graph display, the zoom function is also available.  
10 To display other measurement result screens, press the  
Return softkey to display the previous screen. To end the  
entire test, press the Release softkey to start the BS Release,  
or press the On Hook key on the mobile phone to finish the  
MS Release.  
RF Channels  
Table 4-3 GSM RF channel frequencies and channel number  
GSM850  
GSM900  
DCS1800  
PCS1900  
Uplink  
824.2 to 848.8 MHz  
890.2 to 914.8 MHz  
876.2 to 889.8 MHz  
1710.2 to 1784.8 MHz 1850.2 to 1909.8 MHz  
Downlink  
ARFCN  
869.2 to 893.8 MHz  
128 to 251  
935.2 to 959.8 MHz  
921.2 to 934.8 MHz  
1805.2 to 1879.8 MHz 1930.2 to 1989.8 MHz  
0 to 124  
955 to 1023  
512 to 885  
512 to 810  
GSM900 includes P-GSM, E-GSM, and R-GSM Bands.  
NOTE  
MS Power Control / Power Class  
Table 4-4 GSM Power Control levels  
GSM 850 / 900  
DCS1800  
PCS1900  
Power Control  
Level  
Nominal Power  
(dBm)  
Power Control  
Nominal Power  
(dBm)  
Power Control  
Nominal Power  
(dBm)  
Level  
29  
30  
31  
0
Level  
0
3
4
5
6
39  
37  
35  
33  
31  
36  
34  
32  
30  
28  
30  
31  
0
33  
32  
30  
28  
26  
1
1
2
N9360A Multi UE Tester Quick Reference Guide  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
4
GSM System  
Table 4-4 GSM Power Control levels  
GSM 850 / 900  
DCS1800  
PCS1900  
Power Control  
Level  
Nominal Power  
(dBm)  
Power Control  
Nominal Power  
(dBm)  
Power Control  
Nominal Power  
(dBm)  
Level  
Level  
7
29  
27  
25  
23  
21  
19  
17  
15  
13  
11  
9
2
26  
24  
22  
20  
18  
16  
14  
12  
10  
8
3
24  
22  
20  
18  
16  
14  
12  
10  
8
8
3
4
9
4
5
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
5
6
6
7
7
8
8
9
9
10  
11  
12  
13  
14  
15  
10  
11  
12  
13  
14  
15  
6
6
4
7
4
2
5
2
0
0
GSM 850 / 900  
DCS1800  
PCS1900  
Power Class  
Max Power  
Control Level  
Power Class  
Max Power  
Control Level  
Power Class  
Max Power  
Control Level  
1
2
3
4
5
N/A  
1
2
3
0
3
1
2
3
0
3
2
3
5
7
29  
30  
4-8  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GSM System  
4
RX Level  
Table 4-5 RX levels  
#
0
RX Level  
≤−110 dBm  
#
RX Level  
–89 to –88 dBm  
#
RX Level  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
–67 to –66 dBm  
–66 to –65 dBm  
–65 to –64 dBm  
–64 to –63 dBm  
–63 to –62 dBm  
–62 to –61 dBm  
–61 to –60 dBm  
–60 to –59 dBm  
–59 to –58 dBm  
–58 to –57 dBm  
–57 to –56 dBm  
–56 to –55 dBm  
–55 to –54 dBm  
–54 to –53 dBm  
–53 to –52 dBm  
–52 to –51 dBm  
–51 to –50 dBm  
–50 to –49 dBm  
–49 to –48 dBm  
≥−48 dBm  
1
–110 to –109 dBm  
–109 to –108 dBm  
–108 to –107 dBm  
–107 to –106 dBm  
–106 to –105 dBm  
–105 to –104 dBm  
–104 to –103 dBm  
–103 to –102 dBm  
–102 to –101 dBm  
–101 to –100 dBm  
–100 to –99 dBm  
–99 to –98 dBm  
–98 to –97 dBm  
–97 to –96 dBm  
–96 to –95 dBm  
–95 to –94 dBm  
–94 to –93 dBm  
–93 to –92 dBm  
–92 to –91 dBm  
–91 to –90 dBm  
–90 to –89 dBm  
–88 to –87 dBm  
–87 to –86 dBm  
–86 to –85 dBm  
–85 to –84 dBm  
–84 to –83 dBm  
–83 to –82 dBm  
–82 to –81 dBm  
–81 to –80 dBm  
–80 to –79 dBm  
–79 to –78 dBm  
–78 to –77 dBm  
–77 to –76 dBm  
–76 to –75 dBm  
–75 to –74 dBm  
–74 to –73 dBm  
–73 to –72 dBm  
–72 to –71 dBm  
–71 to –70 dBm  
–70 to –69 dBm  
–69 to –68 dBm  
–68 to –67 dBm  
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
N9360A Multi UE Tester Quick Reference Guide  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4
GSM System  
RX Quality  
Table 4-6 RX Quality  
#
0
1
2
3
RX Quality  
<0.2 %  
#
4
5
6
7
RX Quality  
1.6 to 3.2 %  
3.2 to 6.4 %  
6.4 to 12.8 %  
>12.8 %  
0.2 to 0.4 %  
0.4 to 0.8 %  
0.8 to 1.6 %  
4-10  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5
W-CDMA System  
5-1  
Agilent Technologies  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
W-CDMA System  
For Go/No-Go Testing  
Figure 5-1 [Automatic Test: Stand-by] Screen  
1 Press the Automatic Test softkey on the [Initial] screen for  
W-CDMA system.  
2 Move the cursor to the “Procedure” field, and select a  
pre-defined test procedure.  
3 Press the Start softkey.  
4 Turn the mobile phone on. Wait for completion of Location  
Update.  
5 Operate the mobile phone as instructed in the table below.  
Each test flow step is highlighted as it runs.  
6 After completing the test, check the results on the screen.  
7 To print the measurement results or to save them into a USB  
memory device, press the More (1 of 2) softkey and then the  
Print Screen softkey.  
5-2  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
W-CDMA System  
5
Table 5-1 W-CDMA Automatic Test Sequence  
Step  
Action needed  
Location Update  
MS Call  
Wait until the Location Update is completed.  
Dial an arbitrary number and press the Off Hook key  
on the mobile phone.  
Talk  
Talk to the mobile phone to judge its loop back sound  
quality and press the Pass or Fail softkey.  
MS Release  
BS Call (AMR)  
BS Call (RMC)  
RF Test  
Finish the call from the mobile phone.  
Respond to the call on the mobile phone.  
The mobile phone automatically responds to the call.  
Wait until the RF test is completed.  
BS Release  
Wait until the call is finished from the Tester.  
For Pinpointing Failures  
Figure 5-2 [Automatic Test: Stand-by] Screen  
1 Perform the steps described in “For Go/No-Go Testing.”  
2 Press the Screen>> softkey to set screen mode to Value.  
3 Check the values of the measurement results.  
N9360A Multi UE Tester Quick Reference Guide  
5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5
W-CDMA System  
For Troubleshooting  
Figure 5-3 [Manual Test: Stand-by] Screen  
1 Press the Manual Test softkey on the [Initial] screen.  
2 Move the cursor to the “Procedure” field and select a  
pre-defined test procedure.  
3 Turn the mobile phone on.  
4 Wait for the completion of Location Update.  
5 Select “RMC” for BS Call at the “BS Call” input field.  
6 Press the BS Call softkey.  
7 While “Connection (RMC)” is highlighted in the test flow,  
press the Trigger softkey to start single measurement or the  
Trigger Sing/Cont softkey to start continuous measurement.  
Press the Trigger Sing/Cont softkey again to terminate  
continuous measurement.  
8 Press the Release softkey to finish the Test.  
5-4  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
W-CDMA System  
5
UARFCN  
Table 5-2 W-CDMA Frequency Band  
Band  
Uplink ; mobile phone transmit  
Downlink ; mobile phone receive  
General  
Additional  
General  
Additional  
I
9612 to 9888  
9262 to 9538  
10562 to 10838  
9662 to 9938  
II  
12, 37, 62, 87, 112, 137, 62, 187,  
212, 237, 262, 287  
412, 437, 462, 487, 512, 537, 562,  
587, 612, 637, 662, 687  
III  
IV  
8562 to 8913  
8562 to 8763  
9037 to 9388  
1162, 1187, 1212, 1237,1262,  
1287, 1312, 1337, 1362  
10562 to 10763 1462, 1487, 1512, 1537, 1562, 1587,  
1612, 1637, 1662  
V
VI  
4132 to 4233  
4162 to 4188  
2700 to 2875  
8750 to 8924  
782, 787, 807, 812, 837, 862  
4357 to 4458  
4387 to 4413  
2925 to 3100  
9225 to 9399  
1007, 1012, 1032, 1037, 1062, 1087  
812, 837  
1037, 1062  
VIII  
IX  
Mobile Phone Maximum Output Power  
Table 5-3 UE Maximum Output Power  
Power Class 1  
Power Class 2  
Power Class 3  
Power Class 4  
Operating  
Band  
Power  
(dBm)  
Tol.  
(dB)  
Power  
Tol.  
(dB)  
Power  
(dBm)  
Tol.  
(dB)  
Power  
Tol.  
(dB)  
(dBm)  
(dBm)  
+21  
+21  
+21  
Band I  
Band II  
+33  
+1/–3  
+27  
+1/–3  
+24  
+24  
+24  
+24  
+24  
+24  
+24  
+1/–3  
+1/–3  
+1/–3  
+1/–3  
+1/–3  
+1/–3  
+1/–3  
+2/–2  
+2/–2  
+2/–2  
Band III  
Band IV  
Band V  
Band VI  
Band VIII  
23  
+2/–2  
+2/–2  
+23  
N9360A Multi UE Tester Quick Reference Guide  
5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5
W-CDMA System  
THIS PAGE IS INTENTIONALLY LEFT BLANK.  
5-6  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
cdma2000 System  
6-1  
Agilent Technologies  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
cdma2000 System  
When "CDMA Mode" is set to MC-1x mode  
For Go/No-Go Testing  
Figure 6-1 [Auto Test (MC-1x): Stand-by] Screen  
1 Press the Automatic Test softkey on the [Initial] screen in  
cdma2000 system  
2 Move the cursor to the "Procedure" field, and select a  
pre-defined test procedure.  
3 Press the Start softkey.  
4 Turn the mobile phone on. Wait for the completion of  
Location Update.  
5 Operate the mobile phone as instructed in the table below.  
Each test flow step is highlighted as it runs.  
6 After completing the test, check the results on the screen.  
7 To print the test results or to save them into a USB memory  
device, press the More(1 of 2) softkey and then the Print  
Screen softkey.  
6-2  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
cdma2000 System  
6
Table 6-1 cdma2000 Automatic Test Sequence  
Step  
Action Needed  
Location Update  
MS Call (Talk)  
Wait until the Location Update is complete.  
Dial an arbitrary number and press the Off  
Hook key on the mobile phone.  
Talk  
Talk to the mobile phone to judge its loop  
back sound quality and press the Pass or Fail  
softkey.  
MS Release  
Finish the call from the mobile phone.  
Respond to the call on the mobile phone.  
BS Call (Talk)  
BS Call (RF Test)  
The mobile phone automatically responds to  
the call.  
RF Test  
Wait until the RF test is completed.  
Softer Handoff  
BS Release  
Wait until the Softer Handoff is completed.  
Wait until the call is finished from the Tester.  
N9360A Multi UE Tester Quick Reference Guide  
6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
cdma2000 System  
For Pinpointing Failures  
Figure 6-2 [Auto Test (MC-1x): Stand-by] Screen  
1 Perform the steps described in "For Go/No-Go Testing.”  
2 Press the Screen>> softkey to set screen mode to Value.  
3 Check the values of the measurement results.  
6-4  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
cdma2000 System  
6
For Troubleshooting  
Figure 6-3 [Manual Test (MC-1x): Stand-by] Screen  
1 Press the Manual Test softkey on the [Initial] screen.  
2 Move the cursor to the "Procedure" field and select a  
pre-defined test procedure.  
3 Set the Service Option field to 32.  
4 Turn the mobile phone on.  
5 Wait for the completion of Location Update.  
6 Press the BS Call softkey.  
7 While "Connection" is highlighted in the test flow, press the  
Trigger softkey to start single measurement or the Trigger  
Sing/Cont softkey to start continuous measurement. Press the  
Trigger Sing/Cont softkey again to terminate continuous  
measurement.  
8 Press the Release softkey to finish the test.  
N9360A Multi UE Tester Quick Reference Guide  
6-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
cdma2000 System  
When "CDMA Mode" is set to 1xEV-DO mode  
For Go/No-Go Testing  
Figure 6-4 [Auto Test (1xEV-DO): Stand-by] Screen  
1 Press the Automatic Test softkey on the [Initial] screen in  
cdma2000 system  
2 Move the cursor to the "Procedure" field, and select a  
pre-defined test procedure.  
3 Press the Start softkey.  
4 Turn the mobile phone on. Wait for the completion of UATI  
Assinment.  
5 Each test flow step is highlighted as it runs.  
6 After completing the test, check the results on the screen.  
7 To print the test results or to save them into a USB memory  
device, press the More(1 of 2) softkey and then the Print Screen  
softkey.  
6-6  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
cdma2000 System  
6
Table 6-2 1xEVDO Automatic Test Sequence  
Step  
Action Needed  
UATI Assignment  
BS Call  
Wait until the UATI Assignment is completed.  
The mobile phone automatically responds to the  
call.  
RF Test  
Wait until the RF test is completed.  
Wait until the Softer Handoff is completed.  
Wait until the connection is closed.  
Wait until the session is closed.  
Softer Handoff  
Connection Close  
Session Close  
For Pinpointing Failures  
Figure 6-5 [Auto Test (1xEV-DO): Stand-by] Screen  
1 Perform the steps described in "For Go/No-Go" Testing".  
2 Press the Screen>> softkey to set screen mode to Value.  
3 Check the values of the measurement results.  
N9360A Multi UE Tester Quick Reference Guide  
6-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
cdma2000 System  
For Troubleshooting  
Figure 6-6 [Manual Test (1xEV-DO): Stand-by] Screen  
1 Press the Manual Test softkey on the [Initial] screen.  
2 Move the cursor to the "Procedure" field and select a  
pre-defined test procedure.  
3 Press the UATI Assign softkey.  
4 Turn the mobile phone on, and wait for the completion of  
UATI Assignment.  
5 Press the BS Call softkey.  
6 While "Connection" is highlighted in the test flow, press the  
Trigger softkey to start single measurement or the Trigger  
Sing/Cont softkey to start continuous measurement. Press the  
Trigger Sing/Cont softkey again to terminate continuous  
measurement.  
7 Press the Release softkey to finish the test.  
6-8  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
cdma2000 System  
6
RF Channel  
Table 6-3 cdma2000 Frequency Band  
Radio System  
Channel Number  
1024 ~ 1323  
991 ~ 1023  
1 ~ 799  
BAND0: CEL US  
BAND1: PCS US  
BAND3: Cel JP  
1024 ~ 1323  
991 ~ 1023  
1 ~ 799  
1041 ~ 1199  
1201 ~ 1600  
801 ~ 1039  
1 ~ 799  
BAND4: PCS KR  
BAND6: IMT-2K  
601 ~ 1300  
1 ~ 600  
0 ~ 1199  
† The BAND15: AWS is available only when the Option C03 is installed in the Tester.  
N9360A Multi UE Tester Quick Reference Guide  
6-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
cdma2000 System  
THIS PAGE IS INTENTIONALLY LEFT BLANK.  
6-10  
N9360A Multi UE Tester Quick Reference Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  

2Wire Gas Grill 1 TB LTU license T2526AA SNM User Manual
Accusplit Heart Rate Monitor 602M100R User Manual
Ace Laptop LP Series User Manual
ADC Network Card GigE Series User Manual
AdobeAir Humidifier P500A User Manual
Aiphone Marine Radio NE NVP RA User Manual
Audiovox Remote Starter APS 686 User Manual
Behringer Microphone XM1800S User Manual
Behringer Musical Instrument Amplifier BB115 User Manual
Behringer Music Pedal CC300 User Manual