| Turbo air Speeds Up the Pace of Innovation   Beer Dispenser & Back-Bar Cooler   Installation and Operation Manual   Please read this manual completely before attempting to install or operate this equipment!   TCB-2SD,TCB-3SD, TCB-4SD(Stainless Steel)   TCB-2SB,TCB-3SB, TCB-4SB(Black Paint)   TBD-1SD, TBD-2SD, TBD-3SD, TBD-4SD(Stainless Steel)   TBD-1SB, TBD-2SB, TBD-3SB, TBD-4SB(Black Paint)   TBB-1SB, TBB-2SB, TBB-3SB, TBB-4SB(Solid Door)   TBB-2SG, TBB-3SG, TBB-4SG(Glass Door)   This equipment is intended for the storage and display of non-potentially hazardous, bottled or canned   products only   INSTALLATION OF THE CASTERS   According to model, refer to the assembly position of casters.   TCB-2SD, TBD-2SD, TBB-2SB, TBB-2SG   TCB-3SD, TBD-3SD, TBB-3SB, TBB-3SG   TCB-4SD, TBD-4SD, TBB-4SB, TBB-4SG   ※This picture is a plan view of bottom cabinets.   CB is an abbreviation of the caster with a brake.   Other casters don't have a brake.   DRAFT ARMS TOWERS Installation Schematic Diagram   Screw(M4xL12) x 4EA   Screw(M4xL12) x 4EA   Draft Tower Assembly   Rubber Gasket   Draft Tower Assembly   Rubber Gasket   TCB-2SD, TCB-3SD, TCB-4SD   TBD-2SD, TBD-3SD, TBD-4SD   TBD-2SB, TBD-3SB, TBD-4SB   * Assemble DRAFT TOWER as above drawing.   3 Turbo air   2 BEER LINE & CO LINE Installation Schematic Diagram   Distributor Fixture   CO2 Line   CO2   Beer Line#1   Beer Line#2   Beer #1   Beer #2   TCB-2SD, TCB-3SD, TCB-4SD   TBD-2SD, TBD-3SD, TBD-4SD   TBD-2SB, TBD-3SB, TBD-4SB   * Assemble BEER LINE & CO2 LINE as above drawing.   4 Turbo air   CAUTION "IMPORTANT"   DIRECT DRAW   On direct-draw dispensers the drain is   located at the front of the cabinet.   To plumb in the drain, connect 5/8”   P.V.C. pipe to the 5/8” barbed fitting   supplies with the unit.   * Don't pull out or Turn drain line.   5 Turbo air   CAUTION "IMPORTANT"   TBB-2SG, TBB-3SG,   TBB-4SG   A. Excessively opening the door will cause the breakdown.   B. Handle with care as shutting the door.   1. POWER CORD   - Be sure the power cord is connected to the proper voltage, and amps   should be run before connecting power cord to outlet.   - A protected circuit of the correct voltage and amperage must be run for   connection of the line cord.   - Unplug the unit, whenever performing maintenance functions or cleaning   the refrigerated cabinet.   - Compressor warranty is void if burnt out due to low voltage.   2. RE-STARTING   - If unpluged, wait 5 minutes before re-starting.   6 Turbo air   INSTALLATION   1. GOOD AIR CIRCULATION   - Do not place any object that will restrict air flow in front or back grills.   - Turbo air highly recommends that there is ample space in rear of unit. 3 inches or   more is best.   2. PLACE ON STRONG GROUND   - Be sure the location chosen has a floor strong enough to support the total weight of   the cabinet and contents.   3. DO NOT PLACE NEAR HEAT   - Be sure to avoid hot corners and locations near stoves.   - High ambient temperature will make cooling efficiency lower.   4. INDOOR USAGE ONLY   - Be sure to install this unit indoor, so it will not get wet from the rain.   5. STABILIZING   - Make sure the unit is installed in a stable condition.   6. LEVELING   - Be sure that the unit is level from front to back and side to side.   7. Do not plug in with other units on same breaker.   8. Do not run on extension cord.   7 Turbo air   CLEANING   Before cleaning, unplug the unit.   1. CLEANING THE INTERIOR AND EXTERIOR   - The interior and exterior of the unit can be cleaned using warm water with soap.   - Do not use an abrasive cleaner because it will scratch the surface.   2. CLEANING THE CONDENSER FINS   - To maintain proper refrigeration performance, the Condenser coil must be free of   dust, dirt, and grease.   This will require periodic cleaning. Condenser fins should be cleaned at least every   three months (90 days) or as needed.   - To clean condenser, unplug the unit. Condenser can be cleaned with vacuum, brush,   or CO2 (high pressure air).   3. CLEAN THE GASKET   - The door gasket should be cleaned frequently to maintain proper sealing.   4. CLEAN THE DRAIN PAN   - Empty the Drain Pan which is located under the unit, periodically.   - When reinstalling Drain Pan, make sure Drain Hose is placed back in pan.   5. CHECK AFTER CLEANING   - Plug unit back in.   - Check that the unit is operating properly.   8 Turbo air   BASIC OPERATION   REFRIGERATORS   1. The controller(thermostat) is located at the back right inside of the unit.   2. The factory setting maintains about 38˚F(3˚C) inside.   3. Set toward “counter clock wise” warmer temperature and “clock wise” for colder   temperature.   Temperature Controller   (Thermostat)   4. The thermostat controls compressor’s cycling by sensing inside temperature.   5. When unit will not be used for a long time, unplug the unit.   9 Turbo air   BEFORE REQUESTING SERVICE   SYMPTOMS   CAUSES   SOLUTIONS   Cooler is freezing   products   • Thermostat set too cold.   • Turn the temperature dial to a   warmer setting.   The unit does not   refrigerate at all.   • There is a power connection   failure problem.   • Check the power cord to make   sure the unit is pluged in it   correctly.   The unit does not   refrigerate well.   • The unit is in sunlight or near a • Move out of sunlight or away   heating device.   from heater.   • Product was put in warm.   • The unit door is opened too   • Check the condition of stored   food.   frequently or left open too long. • Check the position of the temp   • The temp. dial is not on the   correct position.   control dial.   • The condenser is clogged.   There is a loud noise.   • The floor is too weak or the   leveling feet are set incorrectly.   • The backside of the unit is too   close to the wall.   • Check the installation.   There are dew-drops   on the unit exterior.   • High-moisture air can produce • Wipe with a dry cloth.   dewdrops during rainy seasons.   There are dew-drops   on the unit interior.   • The door is opened too   frequently or left open too long.   • Keep the door closed to   remove dewdrops.   The following points are not malfunctions:   • A water-flowing sound can be heard when the compressor stops.   This is the sound of REFRIGERANT flowing.   • The compressor does not run during the defrost cycle.   10   Turbo air   Warranty   Warranty Claims   All claims for labor or parts must be made directly through Turbo Air. If unit was manufactured more than one year,   proof of purchase must be faxed in or sent with claim. All claims should include: model number of the unit, the serial   number of the cabinet, and all pertinent information supporting the existence of the alleged defect.   If compressor is replaced under warranty, Turbo Air will either request the compressor or compressor tag be returned.   Compressor or tag must be returned with all information related to the unit. Any action or breach of these warranty   provisions must be commenced within one year after said cause of action has occurred.   One Year Parts & Labor Warranty   Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof,   to be free from defects in material or workmanship, under normal and proper use and maintenance service as   specified by Turbo Air and upon proper installation and start-up in accordance with the instruction packet supplied   with each Turbo Air unit. Turbo Air’s obligation under this warranty is limited to a period of one (1) year from the date   of original installation or 15 months after shipment date from Turbo Air, whichever occurs first.   Any parts, covered under this warranty, that are determined by Turbo Air to have been defective within one (1) year   of original installation or fifteen (15) months after shipment date from manufacturer, whichever occurs first, is limited to   the repair or replacement, including labor charges, of defective parts or assemblies. The labor warranty shall include   standard straight time labor charges only and reasonable travel time, as determined by Turbo Air.   Additional Four Year Compressor Warranty   In addition to the one (1) year warranty stated above, Turbo Air warrants its hermetically sealed compressor to be free   from defects in both material and workmanship under normal and proper use and maintenance service for a period of   four (4) additional years from the date of original installation, but not to exceed five (5) years and three (3) months   after shipment from the manufacturer.   Compressor determined by Turbo Air to have been defective within this extended period will, at Turbo Air’s option, be   either repaired or replaced with a compressor or compressor parts of similar design and capacity.   The four (4) year extended compressor warranty applies only to hermetically sealed parts of the compressor and   does not apply to any other parts or components, including, but not limited to, cabinet, paint finish, temperature   control, refrigerant, metering device, driers, motor starting equipment, fan assembly or and other electrical   component, etcetera.   404A / 134A Compressor Warranty   The four-year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:   1.   2.   3.   This system contains R404A or R134A refrigerant and polyolester lubricant. The polyol ester lubricant has   rapid moisture absorbing qualities.   Drier replacement is very important and must be changed when a system is opened for servicing. A 620   copper drier or better is highly recommended.   Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns or lower   must be obtained.   4.   5.   When compressor is grounded, suction filter drier and 620 drier or better must be replaced.   Compressor must be obtained through Turbo Air Inc., unless otherwise specified in writing, through Turbo   Air’s warranty department.   11   Turbo air   What Is Not Covered By This Warranty   Turbo Air’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the   additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other   than those expressly covered by this warranty.   NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT   LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,   LOSSES, OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT   BECAUSE of REFRIGERATION FAILURE.   WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original   purchaser / user to whom delivered. ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES   HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY   OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.   IMPROPER USAGE. TURBO AIR ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR   COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM IMPROPER USAGE OR INSTALLATION   OR FAILURE TO CLEAN AND / OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET   PROVIDED WITH THE UNIT.   ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION,   FIRE, FLOOD, ACTS OF GOD. Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air   determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident,   damage during transit or installation, fire, flood, or act of God.   IMPROPER ELECTRICAL CONNECTIONS. TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR   REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER   FAILURE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR VOLTAGE DROPS TO THE UNIT.   NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE: THERE   ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE ONE (1) YEAR   PARTS & LABOR WARRANTY AND THE ADDITIONAL FOUR (4) YEAR COMPRESSOR WARRANTY AS   DESCRIBED ABOVE. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,   INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.   THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.   OUTSIDE U.S. AND CANADA: This warranty does not apply to, and Turbo Air is not responsible for, any warranty   claims made on products sold or used outside the United State and Canada.   CHANGES MADE TO WARRANTY COMMENCED ON 5/1/2002   12   Turbo air   1250 Victoria street   CARSON, CA 90746   TEL: 310-900-1000   FAX: 310-900-1077   Toll Free: 1-800-627-0032   (U.S.A. In Canada)   13   Turbo air   |