| Spectrodensitometer   Main specifications   Model   FD-7      FD-5   45°a: 0°(annular illumination)   Illumination/viewing system   Spectral separation device   Wavelength range   Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for reflectance measurements.   Concave grating   - -   FD 7/FD 5   Spectral reflectance: 380 to 730 nm; Spectral irradiance: 360 to 730   nm   Spectral reflectance: 380 to 730 nm   Wavelength pitch   Half bandwidth   10 nm   Approx. 10 nm   Measurement area   Light source   Ø3.5mm   LED   Measurement range   Density: 0.0D to 2.5D; Reflectance: 0 to 150%   Density: σ0.01D   Short-term repeatability   Colorimetric: Within σΔE00 0.05 (When white plate is measured 30 times at 10-second intervals after white calibration has been performed)   Within ΔE00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard   conditions)   Inter-instrument agreement   Measurement time   3-in-1 next-generation measurement tool   Approx. 1.4 s (single-point reflectance measurement)   Colorimetric values, color-difference values, density values, density-   difference values, dot area ratio, dot gain, PASS/FAIL judgment   Colorimetric values, color-difference values, density values,   density-difference values, dot area ratio, dot gain, PASS/FAIL   judgment, illuminance, correlated color temperature   Displayed values   Color   Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut   filter); User-defined illuminant   Measurement conditions   Illuminants   A, C, D50, D65, ID50, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defined illuminant   2° Standard Observer, 10° Standard Observer   Observers           Density   Illumination   Color spaces   Color-difference equations   Indexes   L a b , L C h, Hunter Lab, Yxy, XYZ and color-difference in these color spaces    ΔE ab (CIE 1976), ΔE 94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l:c)   WI (ASTM E313-96); Tint (ASTM E313-96); ISO Brightness (ISO 2470-1); D65 Brightness (ISO 2470-2); Fluorescence index   ISO Status T, ISO Status E, ISO Status A, ISO Status I; DIN16536   Density   Storable data   Display language   Colorimetric target data: 30 data; Density target data: 30 data   English, French, German, Spanish, Japanese, Chinese (Simplified)      Scanning measurements   Interface   Scanning measurement of a color chart can be performed.   USB 2.0   N/A   Displayed values; Spectral reflectance data; Spectral irradiance   data      Output data   Displayed values   Power   Rechargeable internal lithium-ion battery (Number of measurements per charge: Approx. 2,000 when new); AC adapter; USB bus power   70 × 165 × 83mm (Body only); 90 × 172 × 84mm (With target mask attached)   Dimensions (W × D × H)   Weight   Approx. 350g (Body only); Approx. 430g (With target mask attached)   Operating temperature/   humidity range   10 to 35°C, 30 to 85% relative humidity with no condensation   0 to 45°C, 0 to 85% relative humidity with no condensation   Storage temperature/humidity   range     1 Illumination for wavelengths under 400nm is unidirectional. 2 Available when using PC software.   • Displays shown are for illustration purpose only.   (Units: mm)   • The specifications and drawings given here are subject to change without prior notice.   • KONICA MINOLTA and the Konica Minolta logo and the symbol mark, and "Giving Shape to   Ideas" are registered trademarks or trademarks of KONICA MINOLTA HOLDINGS, INC.   • The basICColor logo is a registered trademark of basICColor GmbH.   • Other company names and product names used herein are trademarks or registered trademarks   of their respective companies.   DIMENSIONS   With removable target mask attached   90   70   171.5   165   SAFETY PRECAUTIONS   For correct use and for your safety, be sure to read the instruction   manual before using the instrument.   Always connect the instrument to the specified power supply   s voltage. Improper connection may cause a fire or electric shock.   25   φ6.2   Certificate No : LRQ 0960094/A   Registration Date : March 3, 1995   Certificate No : JQA-E-80027   Registration Date : March 12, 1997   Streamlines color adjustment   in printing, even on substrates   with fluorescent whitening agents   ©2010 KONICA MINOLTA OPTICS, INC.   9242-4897-10 BCJEPK 5   NEW   XY Automatic Color-Measurement Stage   Color Management Software   (Optional accessory)   + ColorScoutA3   (Optional accessory)   basICColor catch all   The ColorScoutA3+ enables accurate, high-efficiency   measurements of color charts with the Spectrodensitometer   FD-7 and FD-5. It enables   automatic positioning and   measurement of the instrument,   For major efficiency increases in daily color control work.   Enables color reproduction closer to visual evaluation with simple operation.   With basICColor catch all, commonly used templates and jobs are already included, so there is no need for measurement preparations such as   setting target values, tolerances, etc.      When the software is started, just select the required measurement conditions in the Job Management screen. You can then connect   immediately to the Spectrodensitometer FD-7 or FD-5, and PDF reports can be created and output automatically.   providing higher repeatability   and reducing labor compared   Data is stored in ISO format (ISO 12642-2), so they can be fed back to profile creation software. Since the FD-7 and FD-5 are the industry's first   spectrodensitometers to offer M1 measurement condition, color reproduction closer to visual evaluation becomes possible.   to manual measurements.   Measure various types of standard color charts to easily check   whether proof and printed colors are within offset printing standards.   When the FD-7 is used, scan measurements (which were impossible with conventional   spectrodensitometers) can be taken, so data from multiple color patches can be obtained in one   operation.    XY automatic color-measurement stage.   Table available with either white surface or black   surface.   Pass/Fail judgement results can be seen at a glance.     Using the ColorScoutA3+ with the FD-7 or FD-5 makes it easier to measure colorimetric data of color   charts under ISO 13655 Measurement Condition M1. Measurement Condition M1 colorimetric data   can be used to create color profiles that more closely match visual evaluation.   Stricter in-house company tolerances or standard tolerance values specified by customers can   be set and the results of pass/fail judgements based on those tolerances can be easily seen.   Three-dimensional color solid display enables easy checking of color shifts.   Target colors can also be created from ICC profiles.     Maximum measurable chart size of 320 x 460 mm improves measurement efficiency by allowing even   large color charts to be measured in a single procedure without the need to cut up or tile the charts.   Measurement of user-designed charts is also possible. The included ColorChart software makes it   easy to create a definition file for measuring the user-designed chart.   For ISO 12647-2 printing certification   checks and print process quality   management.   Enables measurement of Fogra and IDEAlliance   standards and certification checking.     In addition to CIELAB for color, evaluation results   for CMYK dot gain and mid-tone spread as   required for the above certification checking can   also be easily obtained. This can help discover   and resolve problems in the printing process at   an early stage.   Templates/targets for use with Spectrodensitometer FD-7/FD-5   Features   For proof checking Various types of Ugra/Fogra MediaWedge   Color notations   CIELAB; CIEXYZ; Density (ISO Status T, ISO Status E, ISO Status A); Dot gain   Eab (CIE 1976); E94 (CIE 1994; graphics); E94 (CIE 1994; textile); E00   (CIEDE2000); CMC (l:c); DIN99   and QA   CMYK; Various types of IDEAlliance Digital   Control Strip 2009   Color-difference   equations   Observer   easuremenaa   Chart design screen   For printing   Various types of FOGRA Stepwedge;   2°; 10°   certification and QC IDEAlliance P2P25X   Main specifications XY Automatic Color-Measurement Stage ColorScoutA3+   Observation   illuminants   Measurement   conditions   A; B; C; D50; D55; D65; D75; ID50; ID65; E; F1 to F12   For CMYK printer   profile creation   For RGB printer   profile creation   ECI 2002 random; IT8/7-4 random; IT8/7-3   Measurement range   (maximum chart size)   320 x 460 mm   random; basICColor CMYKick-Target7   A (ISO 13655 Measurement Condition M0); C; D50 (ISO 13655 Measurement   Condition M1); D65; ID50; ID65; F2; F6; F7; F8; F9; F10; F11; F12; A+UV cut   (ISO 13655 Measurement Condition M2); User-defined illuminant   Calibration; Spot measurement; Scan measurement (With FD-7 only);   Illumination measurement (With FD-7 only); Job creation/management; Target   value setting (reference file, ICC profile); Averaging of multiple measurements;   Graph display; Report output (Pass/Fail message setting)   Sample ID; CMYK or RGB; CIEXYZ: CIELAB: Density (ISO Status T, ISO   Status E, ISO Status A); Spectral data (With FD-7 only); Dot gain   Color tolerance range control; Primary color control; Dot gain control; Mid-tone   spread control   TC9.18; Various types of basICColor dropRGB   Target   Measuring instrument   Spectrodensitometer FD-7, FD-5   6 x 6 mm   Minimum computing requirements   Minimum chart patch size   OS   Windows® XP SP3 (32-bit); Windows® Vista (32-   Basic functions   Maximum sample thickness 1.5 mm   bit); Windows® 7 (32-bit)   Intel® Pentium® 4 Processor   512MB   Operating temperature/   humidity range   10 to 35°C, relative humidity 30 to 85% with no condensation   CPU   Memory   Hard disk   Display   Storage temperature/   humidity range   -20 to 60°C, relative humidity 0 to 90% with no condensation   Output items   At least 100MB of available disk space   Display unit capable showing at least 1024 x 768   dots/24-bit color (16 million colors)   DVD-ROM drive (for installation)   USB 2.0 port (for instrument connection)   Microsoft Internet Explorer Ver. 7 or later (to   obtain license)   Standard accessories   Mounting bracket for FD-7, Height adjustment plate, ColorChart software, RS-232C   cable, USB to RS-232C serial converter, USB cable AC power cord, White calibration   plate for ColorScoutA3+   Printing control   items   Printing   standards   Import/export   Other   ISO 12647; FOGRA39, FOGRA27; SWOP; GRACoL   ColorChart minimum computing requirements   OS; CPU   Windows® XP(32-bit), Windows® Vista(32-bit); 300MHz or faster   Data files: ISO format (ISO 12642-2); PDF report output; Label printing   English; German; French; Spanish; Italian; Japanese; Chinese (Simplified)   Hard disk; Memory   Display   30MB or more available disk space; 64MB or more   1024 x 800 pixels or more   Compatible instruments   Spectrodensitometer FD-7 and FD-5   Display   languages   |