Crown Boiler BWC151 User Manual

Table of Contents  
I.  
Product Description  
2
II.  
Specications  
2
III. Before Installing  
3
IV. Locating The Boiler  
3
V.  
Mounting The Boiler  
6
VI. Air For Ventilation  
VII. Venting  
9
11  
11  
21  
22  
26  
35  
40  
42  
43  
43  
43  
50  
51  
53  
57  
63  
68  
70  
73  
A. Vent System Design  
B. Removing An Existing Boiler From Common Chimney  
C. Assembly of Crown 60/100mm Concentric Venting  
D. Assembly of Crown 80/125mm Concentric Venting  
E. Assembly of Stainless Steel Venting  
F. Condensate Trap and Drain  
VIII. Gas Piping  
IX. System Piping  
General System Piping Precaution  
System Design  
Standard Piping Installation Requirements  
Piping For Special Situations  
Wiring  
X.  
XI. Start-up and Checkout  
XII. Operation  
XIII. Service and Maintenance  
XIV. Troubleshooting  
XV. Parts  
Appendix A: Optional Method for Retrotting BWC Boilers 85  
into Existing Circulator Zone Systems  
Appendix B: Special Requirements For Side-Wall  
Vented Appliances In The Commonwealth  
of Massachusetts  
87  
1
III Before Installing  
1) Safe, reliable operation of this boiler depends upon installation by a professional heating contractor in strict  
accordance with this manual and the authority having jurisdiction.  
In the absence of an authority having jurisdiction, installation must be in accordance with this manual  
and the National Fuel Gas Code, ANSI Z223.1. In Canada, installation must be in accordance with the  
B149.1 Installation Code  
Where required by the authority having jurisdiction, this installation must conform to the Standard for  
Controls and Safety Devices for Automatically Fired Boilers (ANSI/ASME CSD-1).  
2) BWC boilers utilize aluminum heat exchangers constructed, tested, and stamped in accordance with ASME  
Boiler and Pressure Vessel Code Case 2382. Some jurisdictions which require ASME boiler construction do  
not recognize this Code Case and may not approve the installation of an aluminum boiler. Consult the author-  
ity having jurisdiction before installing this boiler.  
3) Read Section VII to verify that the maximum combustion air and exhaust pipe lengths will not be exceeded in  
the planned installation. Also verify that the vent terminal can be located in accordance with Section VII.  
4) Make sure that the boiler is correctly sized:  
For heating systems employing convection radiation (baseboard or radiators), use an industry accepted  
sizing method such as the I=B=R Heat Loss Calculation Guide (Pub. #H21 or #H22) published by the  
Hydronics Institute in Berkely Heights, NJ.  
For new radiant heating systems, refer to the radiant tubing manufacturer’s boiler sizing guidelines.  
For systems including a Crown Mega-Stor indirect water heater, size the boiler to have either the DOE  
Heating Capacity required for the Mega-Stor or the net rating required for the heating system, whichever  
results in the larger boiler.  
For systems that incorporate other indirect water heaters, refer to the indirect water heater manufacturer’s  
instructions for boiler output requirements.  
5) Make sure that the boiler received is congured for the correct gas (natural or LP).  
6) Make sure that the boiler is congured for use at the altitude at which it is to be installed.  
NOTICE  
This product must be installed by a licensed plumber or gas tter when installed within the  
Commonwealth of Massachusetts. See Appendix A for additional important information about  
installing this product within the Commonwealth of Massachusetts.  
IV Locating the Boiler  
1) Observe the minimum clearances shown in Figure 4.1. These clearances apply to both combustible and non-  
combustible materials. Observe the minimum clearances to combustibles for vent pipe shown in Table 4.2.  
2) Note the recommended service clearances in Figure 4.1. These service clearances are recommended, but may  
be reduced to the combustible clearances provided:  
a. Access to the front of the boiler is provided through a door.  
b. Access is provided to the condensate trap and transformer located underneath the boiler.  
3) When the boiler is installed on the oor using the optional pedestal kit, the boiler may be installed on a non-  
carpeted combustible surface.  
4) The relief valve must be installed in the factory specied location.  
3
Table 4.2: Clearances From Vent Piping To Combustible Construction  
MINIMUM CLEARANCE  
TO COMBUSTIBLE  
MATERIAL  
TYPE OF VENT PIPE  
PIPE DIRECTION  
ENCLOSURE  
80/125 and 60/100mm  
CONCENTRIC VENTING  
VERTICAL OR  
HORIZONTAL  
ENCLOSED ON ALL FOUR SIDES  
0”  
1”  
HEAT FAB SAF-T VENT  
PROTECH FASNSEAL  
Z-FLEX Z-VENT III  
AT LEAST ONE SIDE OPEN,  
COMBUSTIBLE MATERIAL ON A  
MAXIMUM OF THREE SIDES  
VERTICAL OR  
HORIZONTAL  
METAL-FAB CORR/GUARD  
HEAT FAB SAF-T VENT  
PROTECH FASNSEAL  
Z-FLEX Z-VENT III  
HORIZONTAL OR VERTICAL  
WITH OFFSETS  
2-1/2”  
2-1/2”  
ENCLOSED ON ALL FOUR SIDES  
ENCLOSED ON ALL FOUR SIDES  
METAL-FAB CORR/GUARD  
HEAT FAB SAF-T VENT  
PROTECH FASNSEAL  
Z-FLEX Z-VENT III  
VERTICAL WITH NO OFFSETS  
METAL-FAB CORR/GUARD  
5
VI Air for Ventilation  
WARNING  
OUTDOOR COMBUSTION AIR MUST BE PIPED TO THE AIR INTAKE. NEVER PIPE COMBUSTION  
AIR FROM AREAS CONTAINING CONTAMINATES SUCH AS SWIMMING POOLS AND LAUNDRY  
ROOM EXHAUST VENTS. CONTAMINATED COMBUSTION AIR WILL DAMAGE THE BOILER  
AND MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.  
Air for combustion must always be obtained directly from outdoors, however sufcient air for ventilation must  
still be provided in the boiler room. Air for ventilation is required to keep various boiler components from over-  
heating and is always obtained from indoors. To ensure an adequate ventilation air supply, perform the following  
steps:  
Step 1: Determine whether the boiler is to be installed in a conned space - A conned space is dened by the  
National Fuel Gas Code as having a volume less than 50 cubic feet per 1000 BTU/hr input of all appliances  
installed in that space. To determine whether the boiler room is a conned space:  
1) Total the input of all appliances in the boiler room in thousands of BTU/hr. Round the result to the next  
highest 1000 BTU/hr.  
2) Find the volume of the room in cubic feet. The volume of the room in cubic feet is:  
Length (ft) x width (ft) x ceiling height (ft)  
In calculating the volume of the boiler room, consider the volume of adjoining spaces only if no doors are  
installed between them. If doors are installed between the boiler room and an adjoining space, do not consider  
the volume of the adjoining space, even if the door is normally left open.  
3) Divide the volume of the boiler room by the input in thousands of BTU/hr. If the result is less than 50, the  
boiler room is a conned space.  
Example:  
A BWC120 and a water heater are to be installed in a room measuring 6ft – 3 in x 7ft with an 8 ft ceiling. The  
water heater has an input of 30000 BTU/hr:  
Total input in thousands of BTU/hr = (120000 BTU/hr + 30000 BTU/hr) / 1000 = 150 MBTU/hr  
Volume of room = 6.25 ft x 7 ft x 8 ft = 350 ft3  
350/150 = 2.33. Since 2.33 is less than 50, the boiler room is a conned space.  
Step 2a: If the boiler is to be placed in a conned space, provide two openings into the boiler room, one near the  
oor and one near the ceiling. The top edge of the upper opening must be within 12” of the ceiling and the bottom  
edge of the lower opening must be within 12” of the oor (Fig 6.1). The minimum opening dimension is 3 inches.  
If the BWC boiler is the only gas-burning appliance in the boiler room, these openings must each have a  
minimum free area of 100 square inches.  
If other gas-burning appliances are in the boiler room, size the openings in accordance with the appliance  
manufacturer’s instructions or the National Fuel Gas Code. Minimum opening free area is 100 square  
inches even if opening requirements for other appliances are less.  
9
VII Venting  
WARNING  
FAILURE TO VENT THIS BOILER IN ACCORDANCE WITH THESE INSTRUCTIONS COULD CAUSE  
FLUE GAS TO ENTER THE BUILDING RESULTING IN SEVERE PROPERTY DAMAGE, PERSONAL  
INJURY, OR DEATH:  
* Use only vent systems and materials explicitly permitted by Crown for use with this boiler.  
* Do not attempt to mix components from different approved vent systems.  
* Do not obtain combustion air from within the building.  
* Do not install a barometric damper or drafthood on this boiler.  
CAUTION  
Moisture and ice may form on the surfaces around the vent termination. To prevent deterioration,  
surfaces should be in good repair (sealed, painted, etc.).  
A. Vent System Design  
There are four basic ways to vent this boiler:  
• Horizontal (“Side Wall”) Concentric Venting - Vent system exits the building through an outside wall.  
Concentric venting consists of a “pipe within a pipe”. Flue gas exits the building through the inner pipe and  
combustion air is drawn into the boiler through the space between the inner and outer pipe.  
• Horizontal (“Side Wall”) Twin Pipe Venting - Vent system exits the building through an outside wall.  
Combustion air and ue gas are routed between the boiler and outdoors using separate pipes.  
Vertical Concentric Venting - Vent system exits the building through the roof. Concentric venting consists of a  
“pipe within a pipe”. Flue gas exits the building through the inner pipe and combustion air is drawn into the boiler  
through the space between the inner and outer pipe.  
Vertical Twin Pipe Venting - Vent system exits the building through a roof. Combustion air and ue gas are  
routed between the boiler and outdoors using separate pipes.  
All of these systems are considered “direct vent” because in all of them air for combustion is drawn directly from  
the outdoors into the boiler. A description of all of these venting options are shown in Tables 7.1 and 7.9. For clarity,  
these vent options are numbered from 1 to 6. One of the vent option columns in Tables 7.1 or 7.9 must match the  
planned vent and air intake system exactly. In addition, observe the following guidelines:  
1) Approved vent systems - Use only one of the approved vent systems shown in Tables 7.4 or 7.5. These vent systems  
fall into two basic categories:  
Concentric Vent System - The standard boiler is supplied with a concentric vent system having a maximum  
usable length of 25” (Figure 1.1). For longer runs, additional straight lengths and elbows are available from  
Crown. In some cases, larger diameter concentric pipe must be used. Each Crown concentric vent component  
consists of an inner pipe of polypropylene and the outer pipe of steel. Integral gaskets on each concentric tting  
provide a gas tight seal. A list of all Crown concentric vent components is shown in Table 7.4.  
In this manual, concentric pipe sizes are called out in terms of the inner and outer pipe nominal diameters in  
millimeters. For example, “60/100mm” pipe consists of a 60mm exhaust pipe inside a 100mm diameter outer pipe.  
Twin Pipe Vent Systems - Approved vent systems are made of a special stainless steel alloy (AL29-4C) for  
protection against corrosive ue gas condensate. They are designed to provide a gas tight seal at all joints and  
seams so that ue gas does not enter the building. Each approved vent system has a unique method for installation  
- do not attempt to mix components from different vent systems. A list of approved twin pipe vent systems is  
shown in Table 7.5. Note that a special vent collar (Crown PN 230510) is required if the boiler is to be vented  
with one of the approved stainless vent systems.  
11  
2) Maximum Vent and Air Intake Lengths - The maximum length of the vent air intake piping depends upon the vent  
option selected and the boiler size. See Table 7.1 or 7.9 for the maximum vent length. In horizontal vent systems,  
the lengths shown in Table 7.1 are in addition to the rst standard elbow on top of the boiler. For vertical vent  
systems, the maximum vertical vent lengths shown in Table 7.9 are in addition to two standard radius elbows. If more  
elbows are desired, the maximum allowable vent length must be reduced by the amount shown in Table 7.8 for each  
additional elbow used. Termination ttings are never counted, although the length of the concentric terminal section  
is counted.  
Example:  
A 60/100mm concentric vent system is planned for a horizontally vented BWC120 which has the following  
components:  
80/125 x 60/100mm Reducing Elbow (supplied with the boiler)  
5ft Straight Pipe  
90 elbow  
1-1/2ft Straight Pipe  
45Elbow  
Uncut Terminal Section (supplied with the boiler)  
The Vent Option #1 column in Table 7.1 describes a horizontal direct vent system using 60/100mm concentric vent  
pipe. From this column, we see that a BWC120 may have a vent length of up to 18ft. The 90 degree reducing elbow  
is not considered. The length of the terminal section (not including the plastic terminal itself) is approximately 22  
1/2” (1.9ft) installed. From Table 7.8, we see that the equivalent length of the 60/100mm elbow is 4.5ft and that the  
equivalent length of the 45 degree elbow is 4ft. The total equivalent length of the planned venting system is therefore:  
5ft (Straight ) + 4.5ft (90 Elbow) + 1.5ft (Straight ) + 4 ft (45 Elbow) + 1.9ft (Uncut Terminal Section) = 16.9ft.  
Since Table 7.1 shows a maximum allowable vent length of 18ft, the planned vent system length is acceptable.  
3) Minimum Vent and Air Intake Lengths - Observe the minimum vent lengths shown in tables 7.1 and 7.9.  
4) Permitted Terminals for Horizontal Venting:  
Vent Option 1 - The 60/100mm concentric vent terminal is supplied with the boiler as part of the standard vent  
system.  
Vent Option 2 - The exhaust terminal is Crown PN 230511. The air intake tting is a 90 degree elbow with a rodent  
screen supplied by the installer. This elbow is made out of the same material as the rest of the air inlet system  
(either galvanized or PVC) and is installed as shown in Figure 7.3.  
Vent Option 3 - Two terminals are permitted:  
a) 80/125mm Concentric Vent Terminal (Crown PN 230531)  
b) 80/125mm Snorkel Terminal (Crown PN 230540) . This terminal allows the vent system to exit the building  
close to grade and go up the exterior wall far enough to provide adequate clearance between the terminal itself  
and the snow line (Figure 7.7).  
5) Horizontal Vent and Air Intake Terminal Location - Observe the following limitations on the vent terminal location  
(also see Figures 7.6, 7.7). When locating a concentric terminal, observe the limitations outlined below for “vent  
terminals”.  
Vent terminals must be at least 1 foot from any door, window, or gravity inlet into the building.  
• For twin pipe terminals, maintain the correct clearance and orientation between the vent and air intake terminals.  
The vent and air intake terminals must be at the same height and their center lines must be between 12 and 36  
inches apart. Both terminals must be located on the same wall.  
• The bottom of all terminals must be at least 12” above the normal snow line. In no case should they be less than  
12” above grade level.  
• The bottom of the vent terminal must be at least 7 feet above a public walkway.  
• Do not install the vent terminal directly over windows or doors.  
• The bottom of the vent terminal must be at least 3 feet above any forced air inlet located within 10 feet.  
• USA Only: A clearance of at least 4 feet horizontally must be maintained between the vent terminal and gas  
meters, electric meters, regulators, and relief equipment. Do not install vent terminal over this equipment. In  
Canada, refer to B149.1 Installation Code for clearance to meters, regulators and relief equipment.  
• Do not locate the vent terminal under decks or similar structures.  
• Top of vent terminal must be at least 5 feet below eves, softs, or overhangs. Maximum depth of overhang is 3 ft.  
12  
Horizontal Terminal Clearance Requirements (continued):  
Vent terminal must be at least 6 feet from an inside corner.  
• Under certain conditions, water in the ue gas may condense, and possibly freeze, on objects around the vent  
terminal including on the structure itself. If these objects are subject to damage by ue gas condensate, they  
should be moved or protected.  
• If possible, install the vent and air intake terminals on a wall away from the prevailing wind. Reliable operation  
of this boiler cannot be guaranteed if these terminals are subjected to winds in excess of 40 mph.  
• Air intake terminal must not terminate in areas that might contain combustion air contaminates, such as near  
swimming pools. See Section IV for more information on possible contaminates.  
TABLE 7.1: SUMMARY OF HORIZONTAL VENTING OPTIONS  
VENT OPTION #  
1
2
3
CLASSIFICATION USED IN THIS  
MANUAL  
HORIZONTAL  
CONCENTRIC  
HORIZONTAL  
TWIN PIPE  
HORIZONTAL  
CONCENTRIC  
ILLUSTRATED IN FIGURE  
7.2  
7.3  
7.2  
VENT PIPE PENETRATION  
THROUGH STRUCTURE  
WALL  
WALL  
WALL  
AIR INTAKE PIPE PENETRATION  
THROUGH STRUCTURE  
WALL  
WALL  
WALL  
VENT PIPE SIZE  
AIR INTAKE PIPE SIZE  
BWC070  
3”  
60/100 mm  
CONCENTRIC  
80/125 mm  
CONCENTRIC  
3”  
32ft  
32ft  
18ft  
100ft  
100ft  
100ft  
100ft  
100ft  
100ft  
100ft  
100ft  
10in  
10in  
10in  
10in  
10in  
10in  
10in  
10in  
100ft  
100ft  
100ft  
100ft  
100ft  
100ft  
100ft  
100ft  
10in  
10in  
10in  
10in  
10in  
10in  
10in  
10in  
BWC090  
BWC120  
BWC151  
BWC070  
32ft  
32ft  
18ft  
BWC090  
BWC120  
BWC151  
BWC070  
10in  
10in  
10in  
BWC090  
BWC120  
BWC151  
BWC070  
10in  
10in  
10in  
BWC090  
BWC120  
BWC151  
CROWN  
#230511  
Crown 230531  
CONCENTRIC  
or 230540  
VENT TERMINAL  
60/100 mm  
CONCENTRIC  
AIR INTAKE TERMINAL  
3” 90 ELBOW  
SNORKEL  
APPROVED  
STAINLESS  
STEEL VENT  
SYSTEM  
SHOWN IN  
TABLE 7.5  
CROWN  
60/100mm  
VENT  
COMPONENTS  
SHOWN IN  
TABLE 7.4a  
(Note #1)  
CROWN  
80/125mm VENT  
COMPONENTS  
SHOWN IN  
VENT MATERIAL  
TABLE 7.4b  
GALVANIZED  
OR PVC  
AIR INTAKE MATERIAL  
Note #1: In Vent Option #1, the 80/125mm concentric straight section (PN 230515) shown in Table 7.4a may be used between the  
boiler and the rst 80/125 x 60/100 reducing elbow. If this is done, the overall maximum vent length is still restricted to that shown for  
Vent Option #1 in Table 7.1 above.  
13  
TABLE 7.4a: CROWN CONCENTRIC 60/100 VENT COMPONENTS  
(VENT OPTION 1)  
USED ON  
CROWN PN  
DESCRIPTION  
SIZE  
VENT  
COMMENTS  
OPTION #  
80/125 x 60/100mm REDUCING  
ELBOW  
80/125 x  
60/100mm  
INCLUDED WITH STANDARD  
BWC070/090/120  
230521  
230520  
230522  
1
1
1
INCLUDED WITH STANDARD  
BWC070/090/120  
TERMINAL SECTION  
WALL GROMMET  
60/100mm  
60/100mm  
INCLUDED WITH STANDARD  
BWC070/090/120  
230505  
230504  
230506  
230507  
230508  
230515  
39” STRAIGHT  
78” STRAIGHT  
60/100mm  
60/100mm  
60/100mm  
60/100mm  
60/100mm  
80/125mm  
1
1
1
1
1
1
OPTIONAL - MAY NOT BE CUT  
OPTIONAL - MAY NOT BE CUT  
OPTIONAL - CAN BE CUT  
OPTIONAL  
19 1/2” STRAIGHT  
90 DEGREE ELBOW  
45 DEGREE ELBOW  
39” STRAIGHT  
OPTIONAL  
OPTIONAL - CAN BE CUT (Note #1)  
Note #1: On 60/100mm vent systems, this may only be used between the boiler and the rst 80/125 x 60/100 Reducing elbow (see text).  
TABLE 7.4b: CROWN CONCENTRIC 80/125 VENT COMPONENTS  
(VENT OPTIONS 3,6)  
USED ON  
CROWN PN  
DESCRIPTION  
SIZE  
VENT  
COMMENTS  
OPTION #  
230527  
230528  
230526  
230517  
230515  
230518  
230519  
230525  
230531  
230540  
230532  
230533  
230535  
90 DEGREE EL (STANDARD)  
90 DEGREE EL (SWEEP)  
45 DEGREE EL  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
80/125mm  
3,6  
3,6  
3,6  
3,6  
3,6  
3,6  
3,6  
3,6  
3
19 1/2” STRAIGHT  
CAN BE CUT  
CAN BE CUT  
39” STRAIGHT  
39” STRAIGHT  
MAY NOT BE CUT  
78” STRAIGHT  
MAY NOT BE CUT  
TELESCOPING STRAIGHT  
HORIZONTAL TERMINAL  
SNORKEL KIT  
ADJUSTABLE FROM 12-1/2” TO 16-1/2  
3
(NOTE #1)  
(NOTE #2)  
VERTICAL TERMINAL  
FLAT ROOF FLASHING  
SLOPED ROOF FLASHING  
6
6
6
(NOTE #3)  
(NOTE #4)  
SUPPORT ELBOW WITH  
CHIMNEY CHASE BRACKET  
230530  
230536  
80/125mm  
80/125mm  
6
SUPPORT BAND  
3,6  
Table 7.4b Notes:  
1) Snorkel kit includes parts needed to offset terminal on exterior wall by up to 46”.  
2) Vertical terminal can be used with either of the roof ashings listed beneath it.  
3) Sloped roof ashing suitable for roof angles between 25 and 45 degrees.  
4) Used at base of vertical run inside unused masonry chimney.  
15  
6) Permitted Terminals for Vertical Venting -  
Vent Option 5 - A straight termination is installed in the end of the vent pipe. Vent manufacturer part numbers for these  
screens are shown in Table 7.5. The air inlet terminal consists of a 180 degree elbow (or two 90 degree elbows) with a  
rodent screen as shown in Figure 7.10.  
Vent Option 6 - Use Crown PN 230532 with the appropriate ashing (Table 7.4b)  
7) Vertical Vent Terminal Locations (Vent Options 5,6) - Observe the following limitations on the location of all vertical vent  
terminals (see Figures 7.10, 7.11):  
• The top of the vent pipe must be at least 2 feet above any object located within 10 feet.  
• For Vent Option #5, the vertical distance between top of the vent and air inlet terminal openings must be at least 12”.  
• The bottom of the air inlet terminal must be at least 12” above the normal snow accumulation that can be expected on  
the roof. The terminal used in Vent Option #6 has a xed distance above the storm collar of 19”. If a greater distance is  
needed to provide the clearance above the snow line, build a chase on the roof and mount the vertical terminal on top of  
the chase.  
• For Vent Option #5, the air intake terminal must be located on the roof and must be no further than 24” horizontally from  
the exhaust pipe.  
8) Wall thimbles – Wall thimbles are required where single wall vent pipe passes through combustible walls with less than  
the required clearance shown in Table 4.2 or as required by local codes. Stainless vent manufacturer’s wall thimble part  
numbers are shown in Table 7.5. Note that concentric vent has a “zero” clearance to combustibles and therefore does not  
require the use of wall thimbles.  
TABLE 7.5: PERMISSIBLE STAINLESS STEEL VENT SYSTEMS  
AND PRINCIPLE VENT COMPONENTS  
(VENT OPTIONS 2, 5)  
VENT  
SYSTEM  
MANUFACTURER  
SIZE  
COMPONENT  
PART NUMBER  
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
BOILER COLLAR  
CROWN 230510  
HEAT FAB 7393, 7393GCS, 5391CI  
CROWN 230511  
HEAT FAB 9392  
CROWN 230510  
FSWT3  
SAF-T  
VENT  
EZ SEAL  
WALL THIMBLE  
HEAT FAB  
HORIZONTAL TERMINAL  
VERTICAL TERMINAL  
BOILER COLLAR  
PROTECH  
SYSTEMS  
INC.  
WALL THIMBLE  
FASNSEAL  
HORIZONTAL TERMINAL  
VERTICAL TERMINAL  
BOILER COLLAR  
CROWN 230511  
FSBS3  
CROWN 230510  
2SVSWTEF03  
SVE  
SERIES III  
(“Z-VENT  
III”)  
WALL THIMBLE  
Z-FLEX  
HORIZONTAL TERMINAL  
VERTICAL TERMINAL  
BOILER COLLAR  
CROWN 230511  
24SVSTPF03  
CROWN 230510  
CGSWWPK(3”)  
CROWN 230511  
CGSWHTM(3”)  
WALL THIMBLE  
CORR/  
GUARD  
METAL-FAB  
HORIZONTAL TERMINAL  
VERTICAL TERMINAL  
NOTES:  
1) See vent system manufacturer’s literature for other part numbers that are required such as straight pipe, elbows, restops and vent supports.  
2) Crown 230510 collar replaces factory-mounted concentric collar (Figure 7.16).  
16  
9) Pitch of Horizontal Piping - Pitch all horizontal piping so that any condensate which forms in the piping will run  
towards the boiler:  
• Pitch Crown horizontal concentric venting 5/8” per foot  
• Pitch Stainless steel venting 1/4” per foot.  
10) Supporting Pipe - Vertical and horizontal sections of pipe must be properly supported:  
• Support Crown concentric venting near the female end of each straight section of pipe.  
Exception: Vertical runs of concentric pipe in an unused chinmey (Figure 7.36) need only be supported at the  
terminal and at the base of the run.  
• Support stainless steel venting as called for by the vent manufacturer’s instructions.  
FIGURE 7.7: SNORKEL TERMINAL CONFIGURATION  
18  
TABLE 7.8: VENT/ AIR INTAKE FITTING EQUIVALENT LENGTH  
VENT FITTING  
60/100mm 90° CONCENTRIC ELBOW  
EQUIVALENT LENGTH (ft)  
4.5  
60/100mm 45° CONCENTRIC ELBOW  
80/125mm 90° CONCENTRIC ELBOW  
80/125mm 90° SWEEP CONCENTRIC ELBOW  
80/125mm 45° CONCENTRIC ELBOW  
80/125mm 90° CONCENTRIC SUPPORT ELBOW  
3” SINGLE WALL 90° ELBOW  
4.0  
8.5  
5.5  
3.0  
8.5  
5.5  
4.0  
3” SINGLE WALL 45° ELBOW  
TABLE 7.9: SUMMARY OF VERTICAL VENTING OPTIONS  
VENT OPTION #  
5
6
CLASSIFICATION USED IN THIS  
MANUAL  
VERTICAL  
TWIN PIPE  
VERTICAL  
CONCENTRIC  
ILLUSTRATED IN FIGURE  
7.10  
7.11  
VENT PIPE PENETRATION  
THROUGH STRUCTURE  
ROOF  
ROOF  
AIR INTAKE PIPE STRUCTURE  
THROUGH STRUCTURE  
ROOF  
ROOF  
VENT PIPE SIZE  
AIR INTAKE PIPE SIZE  
BWC070  
3”  
3”  
80/125 mm CONCENTRIC  
98ft  
98ft  
98ft  
98ft  
98ft  
98ft  
98ft  
98ft  
2ft  
95ft  
95ft  
95ft  
95ft  
95ft  
95ft  
95ft  
95ft  
2ft  
BWC090  
BWC120  
BWC151  
BWC070  
BWC090  
BWC120  
BWC151  
BWC070  
BWC090  
BWC120  
BWC151  
BWC070  
BWC090  
BWC120  
BWC151  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
2ft  
STRAIGHT TERMINAL  
BY VENT SYSTEM MFR.  
(TABLE 7.5)  
VENT TERMINAL  
CROWN #230532  
CONCENTRIC TERMINAL  
(TABLE 7.4b)  
3” 180° ELBOW  
(FIGURE 7.10)  
AIR INTAKE TERMINAL  
APPROVED STAINLESS  
STEEL VENT SYSTEM  
CROWN 80/125 mm VENT  
COMPONENTS SHOWN IN  
TABLE 7.4b  
VENT MATERIAL  
AIR INTAKE MATERIAL  
GALVANIZED OR PVC  
19  
FIGURE 7.10: VERTICAL TWIN PIPE VENT SYSTEM (VENT OPTION 5)  
FIGURE 7.11: VERTICAL CONCENTRIC VENT SYSTEM (VENT OPTION 6)  
20  
B. Removing an Existing Boiler From a Common Chimney  
Read this only if the BWC boiler is replacing an existing boiler that is being removed from a common chimney. This  
section does not apply to the installation of a BWC boiler.  
In some cases, when an existing boiler is removed from a common chimney, the common venting system may be too  
large for the remaining appliances. At the time of removal of an existing boiler, the following steps shall be followed  
with each appliance remaining connected to the common venting system placed in operation, while the other appliances  
remaining connected to the common venting system are not in operation.  
(a) Seal any unused openings in the common venting system.  
(b) Visually inspect the venting system for proper size and horizontal pitch and determine there is no blockage or  
restriction, leakage, corrosion and other deciencies which could cause an unsafe condition.  
(c) Insofar as practical, close all building doors and windows and all doors between the space in which all the  
appliances remaining connected to the common venting system are located and other spaces of the building.  
Turn on clothes dryers and any appliance not connected to the common venting system. Turn on any exhaust  
fans, such as range hoods and bathroom exhausts, so they will operate at maximum speed. Do not operate a  
summer exhaust fan. Close replace dampers.  
(d) Place in operation the appliance being inspected. Follow the lighting instructions. Adjust thermostat so the  
appliance will operate continuously.  
(e) Test for spillage at the draft hood relief opening after 5 minutes of main burner operation. Use the ame of a  
match or candle, or smoke from a cigarette, cigar, or pipe.  
(f) After it has been determined that each appliance remaining connected to the common venting system properly  
vents when tested as outlined above, return doors, windows, exhaust fans, replace dampers and any other  
gas-burning appliances to their previous condition of use.  
(g) Any improper operation of the common venting system should be corrected so the installation conforms with  
the National Fuel Gas Code, ANSI Z223.1. When re-sizing any portion of the common venting system, the  
common venting system should be re sized to approach the minimum size as determined using the appropriate  
tables in Part 11 of the National Fuel Gas Code, ANSI Z223.1.  
WARNING  
NEVER COMMON VENT A BWC BOILER WITH OTHER APPLIANCES.  
21  
C. Assembly of Crown 60/100mm Concentric Venting  
(IMPORTANT - Skip to Section D for 80/125mm Concentric Vent Assembly)  
WARNING  
Failure to follow the instructions could result in ue gas leakage into the combustion air or indoor air,  
resulting in unsafe or unreliable operation.  
• Do not lubricate concentric gaskets with anything other than water.  
• Do not attempt to cut any piping except as permitted in this section. When cutting these sections, make sure  
all cuts are square and allow for proper insertion.  
• Do not attempt to try to mix this concentric pipe with other venting systems.  
1) Concentric vent components supplied with the boiler are packed inside the BWC070/090/120 carton and include  
the following:  
a) 80/125 x 60/100mm reducing elbow (Crown PN 230521).  
b) 60/100mm terminal section (straight section with a terminal and overall length of 27 3/4” (Crown PN 230520).  
c) Two (2) Rubber wall grommets (Crown PN 230522).  
2) Unless the 80/125 straight riser (PN 230515) is used, start by attaching the reducing elbow to the boiler collar. To  
do so, remove the clamp from the large end of the reducing elbow and set aside. Apply a small amount of water to  
the brown gasket on the boiler collar. Push the elbow onto the boiler collar until the bead on the elbow contacts the  
top edge of the collar (Figure 7.20).  
3) Reinstall the clamp removed in Step (2) so that the elbow is secured to the boiler collar.  
4) If no additional sections of concentric pipe are required, attach the terminal section to the elbow. In most cases, it  
will need to be cut before doing so. Use the following procedure to cut the pipe:  
a) Measure distance “L” from the outside surface of the exterior wall to the end of the elbow as shown in Figure  
7.21.  
b) Add 2-1/8” to distance “L”. Carefully mark this length on the pipe as shown in Figure 7.22.  
c) Press in the two tabs holding the plastic terminal in the terminal section (Figure 7.22). Carefully pull out the  
terminal and the inner pipe.  
d) Cut the outer pipe only at the point marked in Step (b) using aviation shears, a hacksaw, or an abrasive wheel  
cutter. Be careful to cut the pipe square. De burr the cut end with a le or emery cloth.  
e) Cut the plastic inner pipe so that it will protrude 3/8” beyond the outer pipe when reinstalled in the terminal  
section (Figure 7.23). Use a ne tooth hacksaw or a PVC saw to cut the plastic pipe and be careful to cut the pipe  
square. De burr the cut edge of the plastic pipe with a le, razor blade, or ne sandpaper.  
f) Reinstall the inner pipe in the terminal section. Slip the outside wall grommet over the terminal section and  
position so that it covers the joint between the outer pipe and the terminal (Figure 7.24).  
g) Make a mark on the terminal section 1” from the cut end of the outer pipe as shown in Figure 7.24.  
h) Pass the terminal section through the wall from the outside. Push the remaining wall grommet over the terminal  
section on the inside of the wall. Push the terminal section into the elbow until the mark made in Step (g) is no  
longer visible. If necessary, the brown gasket in the inner pipe may be lubricated with a few drops of water.  
i) The terminal section must be attached to the elbow with a single #10 x 1/2” sheet metal screw ( not supplied) at  
the top of the elbow. Drill a 1/8” hole in the location shown in Figure 7.25. Use a short drill bit or a drill stop  
to ensure that the drill bit does not penetrate the pipe by more than 3/8”. Install a #10 x 1/2” screw in this  
hole. Do not use a screw longer than 1/2” long.  
j) If not already done, make sure that both wall grommets are rmly against the interior and exterior wall surfaces.  
Seal any cracks or other openings near the terminal through which exhaust could enter the building.  
5) If additional pieces of pipe are used, install them starting at the boiler elbow. Support each section of straight pipe  
at its female end.  
22  
D. Assembly of Crown 80/125mm Concentric Venting  
(IMPORTANT - See Section C for 60/100mm Concentric Vent Assembly)  
WARNING  
Failure to follow the instructions could result in ue gas leakage into the combustion air or indoor air,  
resulting in unsafe or unreliable operation.  
• Do not lubricate concentric gaskets with anything other than water.  
• Do not attempt to cut any piping except as permitted in this section. When cutting these sections, make sure  
all cuts are square and allow for proper insertion.  
• Do not attempt to try to mix this concentric pipe with other venting systems.  
1) When BWC070, BWC090, or BWC120 boilers are vented using 80/125 venting, the 60/100 terminal section  
and reducing elbow supplied with the boiler are not used. The components listed in Table 7.4b are required for  
80/125mm installations and are not supplied.  
The BWC151 is supplied with the following 80/125 components:  
a)  
b)  
80/125 Standard Radius Elbow  
80/125 Terminal Section  
Before starting assembly of an 80/125 vent system, make sure that the planned installation is in accordance with the  
Vent System Design” Section of this manual and that all required 80/125mm vent components are on hand. Any  
components not supplied with the boiler are available through Crown distributors.  
FIGURE 7.30a: CUTTABLE STRAIGHT SECTION  
FIGURE 7.30b: NON CUTTABLE STRAIGHT SECTION  
26  
3) Assembly of Metal-Fab Corr/Guard Vent System:  
a) Corr/Guard General Notes:  
• Do not cut Corr/Guard vent components.  
• Refer to Corr/Guard installation instructions for proper methods of support.  
• Orient Corr/Guard components so that the males ends of all ttings point in the direction of the boiler.  
b) Start assembly of the vent system at the boiler. Remove the hose clamp shipped on the BWC vent collar. Bend  
the three hose clamp tabs on this collar outward slightly.  
c) Clean the exterior of the male end of the rst piece of pipe and the inside of the vent collar on the boiler. Remove  
dirt, grease, and moisture from the surfaces to be sealed. Dry surfaces or allow to dry thoroughly.  
d) On the male end of the pipe, apply a ¼” wide bead of silicone approximately 1/2” from the end of the pipe (Fig  
7.47).  
e) Insert the male end of the pipe into the boiler vent collar until it bottoms out.  
f) Apply an additional bead of silicone over the outside of the joint and smooth out.  
g) Replace and tighten the clamp on the vent collar.  
h) Assemble remaining Corr/Guard components in accordance with the Corr/Guard installation instructions.  
i) Allow the silicone to cure per the silicone manufacturer’s instructions before operating the boiler.  
FIGURE 7.47: CORR/GUARD CONNECTION TO VENT COLLAR  
36  
4) Assembly of Z-Flex Z-Vent III:  
a) General Notes:  
• Non-expanded ends of SVE Series III piping sections may be cut using aviation snips or a 24 thread per inch  
hacksaw. File or sand the cut end smooth before assembling. Expanded ends may be cut to adapt the SVE  
series III to the vent collar. See the following instructions.  
• Support horizontal piping sections at intervals of 48” or less.  
Vertical venting systems must be supported by at least one Z-Flex re stop. An additional vertical support is  
required after any offset and as required by the Z-Vent III installation instructions.  
b) Start assembly of the vent system at the boiler. Remove the hose clamp shipped on the BWC vent collar. Bend  
the three hose clamp tabs on this collar outward slightly.  
c) Clean the exterior of the male end of the rst piece of pipe and the inside of the vent collar on the boiler. Remove  
dirt, grease, and moisture from the surfaces to be sealed. Dry surfaces or allow to dry thoroughly.  
d) On the male end of the pipe, apply a ¼” wide bead of high temperature silicone approximately ½ inch from the  
male end of the pipe. Apply ¼” beads of silicone along both sides of the longitudinal seam (Fig. 7.48).  
e) Insert the male end of the pipe into the boiler vent collar until it bottoms out.  
f) Apply an additional bead of silicone over the outside of the joint and smooth out.  
g) Replace and tighten the clamp on the vent collar.  
h) The female end of each Z-Vent III component has a silicone sealing gasket. Examine all vent components to  
insure that the gasket integrity has remained during shipping. Gaskets must be in the proper position or ue gas  
could leak resulting in carbon monoxide poisoning.  
i) Align the second piece of pipe with the rst and push them together as far as they will go, but not less than 1-  
3/4”.  
j) Tighten gear clamp to a minimum torque of 40 in-lbs and a maximum of 50 in-lbs.  
k) Repeat Steps (h) – (j) for the remaining Z-Vent III components.  
l) In horizontal vent systems, a locking band or gear clamp must be used at either side of the wall penetration to  
prevent shifting of the vent system in and out of the wall. This applies to both combustible and non-combustible  
walls.  
n) Allow the silicone to cure per the silicone manufacturer’s instructions before operating the boiler.  
FIGURE 7.48: Z-VENT III CONNECTION TO VENT COLLAR  
37  
5) Assembly of Heat Fab Saf-T Vent EZ Seal:  
a) Saf-T Vent General Notes:  
• These instructions cover the installation of Saf-T Vent EZ Seal. Saf-T Vent EZ Seal piping has integral gaskets  
installed in the female ends of the pipe which seal the joints.  
• In general, Saf-T Vent pipe sections may not be cut. Exceptions to this are the Saf-T Vent slip connector and  
connections to the boiler vent collar.In these cases, use a sharp pair of aviation snips, an abrasive cut-off, or a  
plasma cutter. See the Saf-T Vent instructions for information on cutting the slip connector.  
• Orient Saf-T Vent components so that the arrows on the piping labels are in the direction of ue gas ow.  
• Support horizontal piping sections at intervals of 6 feet or less.  
Vertical venting systems must be supported by at least one Heat Fab support. An additional vertical support is  
required after any offset.  
b) Connection to Boiler – Start assembly of the vent system at the boiler. Remove the hose clamp shipped on the  
BWC vent collar. Bend the three hose clamp tabs on this collar outward slightly. Cut the “male spigot” off of  
the rst piece of pipe (Fig 7.49). If necessary, crimp the cut end of the pipe so that it can be inserted at least 1”  
into the collar. Clean the exterior of the male end of the rst piece of pipe and the inside of the vent collar on  
the boiler with an alcohol pad. On the male end of the pipe, apply a ¼” wide bead of high temperature silicone  
approximately ½ inch from the male end of the pipe. Also apply a ¼” bead of silicone along the rst 2 ½” of  
the longitudinal weld. Insert the male end of the pipe into the boiler vent collar until it bottoms out. Apply an  
additional bead of silicone over the outside of the joint and smooth out (Fig 7.49). Replace and tighten the clamp  
on the vent collar.  
c) Assembly of Saf-T Vent EZ Seal Vent Components - Clean the male end of the next piece of pipe with an alcohol  
pad and make sure that it is free of burrs. Check the female end of the rst piece of pipe to make sure that the  
gasket is in place and is undamaged. Using a slight twisting motion, insert the male end of the second tting  
into the female end of the rst tting, taking care not to dislodge or cut the factory gasket. In extremely arid  
conditions, it may be easier to assemble these ttings if the gasket is moistened with water prior to assembly.  
Bend the locking tabs over the locking ring on the adjacent piece of pipe. Repeat these steps for the remaining  
Saf-T-Vent components.  
FIGURE 7.49: SAF-T VENT EZ SEAL CONNECTION TO VENT COLLAR  
38  
8) Installation of Vertical Exhaust Terminal - Use the terminal supplied by the vent system manufacturer shown in  
Table 7.5. Attach to the vent system, following the assembly instructions in this manual for the stainless vent system  
being used.  
9) Assembly of the Air Intake System and Air Intake Terminals:  
a) Assemble the air intake system using either galvanized or PVC pipe.  
b) If PVC piping is used, use PVC cement to assemble the PVC intake system components.  
c) If galvanized piping is used, use at least two sheet metal screws per joint. Seal the outside of all joints.  
d) 3” galvanized smoke pipe will t inside the inlet collar on the boiler. Depending upon the exact OD of the pipe  
used, it may be necessary to crimp this pipe. Secure with a single #10 sheet metal screw through the hole in the  
inlet collar and seal the outside of the joint with silicone. If PVC is used for the intake system, use a short piece  
of 3” galvanized pipe to connect the PVC to the boiler. Silicone the outside of the joint between the PVC and  
galvanized pipe.  
e) Horizontal intake terminal is a 90 degree elbow pointing down. Elbow should protrude the same distance from  
the wall as the exhaust terminal.  
f) Vertical air intake terminal consists of a 180 degree bend (composed of two 90 degree elbows) as shown in  
Figure 7.10.  
g) Install a rodent screen (not supplied) in the inlet terminal. Use a screen having 1/2” (2 x 2) or larger mesh.  
F. Condensate Trap and Drain Line  
All condensate which forms in the boiler or vent system collects in the sump under the heat exchanger and  
leaves the boiler through the condensate trap. This trap allows condensate to drain from the sump while retaining ue  
gases in the boiler. The trap is supplied loose and must be installed as shown in Figure 7.51. A length of drain hose is  
supplied with the boiler and is connected to the trap as shown in Figure 7.51. Note the following when disposing of the  
condensate:  
a) If the condensate drain line must be extended, construct the extension from PVC or CPVC pipe. Insert the hose  
provided with the boiler into the end of the extension as shown in Figure 7.51.  
b) Condensate is slightly acidic. Do not use metallic pipe or ttings in the condensate drain line. Do not route the  
drain line through areas that could be damaged by leaking condensate.  
c) Some jurisdictions may require that the condensate be neutralized before being disposed of. Dispose of  
condensate in accordance with local codes.  
d) Do not route, or terminate, the condensate drain line in areas subjected to freezing temperatures.  
e) If the point of condensate disposal is above the trap, it will be necessary to use a condensate pump to move  
the condensate to the drain. In such cases, select a condensate pump that is approved for use with condensing  
furnaces. If overow from this pump would result in property damage, select a pump with an overow switch  
and use this switch to shut down the boiler. Alternatively, if heat is a necessity, use the overow switch to trigger  
an alarm.  
f) Do not attempt to move the trap from the location shown in Figure 7.51. Do not attempt to substitute another trap  
for the one provided with the boiler.  
g) The vent shown in Figure 7.51 must be left open for the trap to work properly.  
WARNING  
FAILURE TO INSTALL THE CONDENSATE TRAP AND CONDENSATE DRAIN IN ACCORDANCE WITH  
THE ABOVE INSTRUCTIONS COULD CAUSE FLUE GAS TO ENTER THE BUILDING, RESULTING IN  
PERSONAL INJURY OR DEATH.  
CAUTION  
BOILER CONDENSATE IS CORROSIVE. ROUTE CONDENSATE DRAIN LINE IN A MANNER SUCH  
THAT ANY CONDENSATE LEAKAGE WILL NOT CAUSE PROPERTY DAMAGE.  
40  
IX System Piping  
A. General System Piping Precautions  
WARNING  
INSTALL BOILER SO THAT THE GAS IGNITION SYSTEM COMPONENTS ARE PROTECTED  
FROM WATER (DRIPPING, SPRAYING, RAIN, ETC) DURING APPLIANCE OPERATION AND  
SERVICE (CIRCULATOR REPLACEMENT, ETC).  
CAUTION  
THE HEAT EXCHANGER USED IN THE BWC IS MADE FROM A SPECIAL ALUMINUM ALLOY.  
FAILURE TO TAKE THE FOLLOWING PRECAUTIONS COULD RESULT IN SEVERE BOILER  
DAMAGE.  
• BEFORE CONNECTING BOILER, MAKE SURE THAT THE SYSTEM IS FREE OF SEDIMENT,  
FLUX AND ANY RESIDUAL BOILER WATER ADDITIVES. FLUSH THE SYSTEM IF  
NECESSARY TO ENSURE THAT THESE CONTAMINATES ARE REMOVED.  
• DO NOT CONNECT THIS BOILER TO A SYSTEM THAT IS SUBJECT TO REGULAR ADDITIONS  
OF MAKEUP WATER OR ONE WHICH EMPLOYS RADIANT TUBING WITHOUT AN OXYGEN  
BARRIER.  
• DO NOT ADD ANTIFREEZE OR OTHER BOILER WATER TREATMENT CHEMICALS EXCEPT  
THOSE LISTED IN PART XI OF THIS MANUAL.  
• MAINTAIN THE PRESSURE IN THE BOILER AT A MINIMUM OF 12 PSI.  
• DESIGN SYSTEM TO ENSURE THAT THE FLOW FALLS WITHIN THE LIMITS CALLED FOR IN  
TABLE 9.1.  
B. System Design  
Proper operation of the BWC boiler requires that the water ow through the boiler remain within the limits shown in  
Table 9.1 any time the burner is ring. Failure to maintain the ow within these limits could result in erratic operation or  
premature boiler failure.  
There are two basic methods that can be used to pipe the BWC boiler. Method #1 is almost always preferred. The  
instructions on the following pages describe these methods for piping BWC boilers and explain how to size the circulator  
and piping. Additional information on hydronic system design may be found in Installation of Residential Hydronic  
Systems (Pub. #200) published by the Hydronics Institute in Berkeley Heights, NJ.  
TABLE 9.1: FLOW REQUIREMENTS THROUGH BOILER  
MIN. REQUIRED FLOW  
(GPM)  
MAX. ALLOWABLE  
FLOW (GPM)  
BOILER MODEL  
BWC070  
BWC090  
BWC120  
BWC151  
4.0  
4.0  
4.5  
6.0  
9.0  
9.0  
12.0  
15.0  
43  
TABLE 9.6: PIPE AND CIRCULATOR SIZING FOR INDIRECT WATER HEATER LOOP  
(a)  
(b)  
(c)  
(d)  
(e)  
(f)  
MAX. I.W.H.  
PRESSURE  
DROP  
I.W.H. LOOP MAX  
EQUIVALENT  
LENGTH  
BOILER  
MODEL  
PIPE  
SIZE  
CROWN INDI-  
RECT WATER  
HEATERS  
FLOW  
(GPM)  
CIRCULATOR  
MODEL  
(in NPT)  
(ft)  
(ft HEAD)  
MS-26 (*)  
MS-40 (*)  
MSH-40H (*)  
MT040GBR (*)  
BWC070  
BWC090  
1
6.0  
8.0  
1.7  
Taco 008  
122  
MS-26  
MS-40 (*)  
MSH-40H  
MT040GBR (*)  
1
1
3.0  
3.0  
Taco 0014  
78  
MS-26  
MS-40  
MSH-40H  
MT040GBR  
MT050GBR  
MT065GBR  
MT080GBR  
BWC120  
8.0  
Taco 0014  
108  
BWC120  
BWC151  
1
1
8.0  
8.0  
5.0  
3.0  
MSH-53H  
Taco 0014  
Taco 008  
70  
49  
MS-26  
MS-40  
MSH-40H  
MT040GBR  
MT050GBR  
MT065GBR  
MT080GBR  
MS-53  
BWC151  
1
8.0  
5.0  
MS-53H  
MSH-79(*)  
Taco 0014  
150  
TABLE 9.6 NOTES:  
1) Indirect water heaters with an asterisk (*) will not achieve their catalog rating due to inadequate boiler water ow  
and/or inadequate boiler output.  
TABLE 9.7: FITTING EQUIVALENT LENGTHS  
PIPE SIZE  
EQUIVALENT LENGTH (ft)  
FITTING  
90 ELBOW  
1
1
1
1
1
2.75  
5.50  
1.75  
7.00  
0.60  
TURN IN TEE  
RUN OF TEE  
SWING CHECK  
GATE VALVE  
48  
19.00  
18.00  
17.00  
16.00  
15.00  
14.00  
13.00  
12.00  
11.00  
10.00  
9.00  
BWC120  
BWC070, BWC090  
BWC151  
8.00  
7.00  
6.00  
5.00  
4.00  
3.00  
2.00  
1.00  
0.00  
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
FLOW (GPM)  
Figure 9.9: Boiler Head Loss  
C: Standard Piping Installation Requirements  
Observe the following guidelines when making the actual installation of the boiler piping:  
1) The relief valve is packaged loose with the boiler and must be installed in the location shown in Figure 2.1. The  
relief valve is set to open at 30 psi. If the valve is replaced, the replacement must have a relief capacity in excess of  
the DOE heating capacity for the boiler. Pipe the discharge of the relief valve to a location where water or steam  
will not create a hazard or cause property damage if the valve opens. The end of the discharge pipe must terminate  
in an unthreaded pipe. If the relief valve discharge is not piped to a drain, it must terminate at least 6 inches above  
the oor. Do not run relief valve discharge piping through an area that is prone to freezing. The termination of the  
relief valve discharge piping must be in an area where it is not likely to become plugged by debris.  
DANGER  
 PIPE RELIEF VALVE DISCHARGE TO A SAFE LOCATION.  
 DO NOT INSTALL A VALVE IN THE RELIEF VALVE DISCHARGE LINE.  
 DO NOT INSTALL RELIEF VALVE IN A LOCATION OTHER THAN THAT SPECIFIED BY THE  
FACTORY.  
 DO NOT PLUG THE RELIEF VALVE DISCHARGE.  
50  
2) Circulator (Required) - Usually at least two circulators will be required to properly install a BWC Series boiler. See  
the previous section for information on sizing the circulators.  
3) Expansion Tank (Required) - If this boiler is replacing an existing boiler with no other changes in the system, the  
old expansion tank can generally be reused. If the expansion tank must be replaced, consult the expansion tank  
manufacturer’s literature for proper sizing.  
4) Fill Valve (Required) - Either a manual or automatic ll valve may be used. The ideal location for the ll is at the  
expansion tank.  
5) Automatic Air Vent (Required) - At least one automatic air vent is required. Manual vents will usually be required  
in other parts of the system to remove air during initial ll.  
IMPORTANT  
If there are any downturns, or downward pitches, in the boiler supply piping between the  
boiler and the automatic air vent mounted on the system’s air separator, install a second  
automatic air vent in the supply piping as close as possible to the boiler (Figures 9.2-9.4).  
This will prevent nuisance low water cut-off lockouts due to trapped air.  
6) Manual Reset High Limit (Required by some codes) - This control is required by ASME CSD-1 and some other  
codes. Install the high limit in the boiler supply piping just above the boiler with no intervening valves. Set the  
manual reset high limit to 200°F. Wire the limit per Figures 10.1 & 10.2 in the Wiring section.  
7) Flow Control Valve (Required) - The ow control valve prevents ow through the system unless the circulator is  
operating. Flow control valves are used to prevent gravity circulation or “ghost ows” in circulator zone systems  
through zones that are not calling for heat.  
8) Isolation Valves (Recommended) - Isolation valves are useful when the boiler must be drained, as they will  
eliminate having to drain and rell the entire system.  
9) Drain Valve (Required) - The drain valve is installed on the return tee located in the lower vestibule compartment  
as shown in Figure 9.2.  
10) Low Water Cut-off (Required) - The low water cut-off supplied with this boiler must not be removed.  
D. Piping for Special Situations  
1) Systems containing oxygen - Many hydronic systems contain enough dissolved oxygen to cause severe corrosion  
damage to an aluminum boiler such as the BWC. Some examples include:  
Radiant systems that employ tubing without an oxygen barrier.  
Systems with routine additions of fresh water.  
Systems which are open to the atmosphere.  
If the boiler is to be used in such a system, it must be separated from the oxygenated water being heated with a  
heat exchanger as shown in Figure 9.10. Consult the heat exchanger manufacturer for proper heat exchanger sizing  
as well as ow and temperature requirements. All components on the oxygenated side of the heat exchanger, such  
as the pump and expansion tank, must be designed for use in oxygenated water.  
2) Piping with a Chiller - If the boiler is used in conjunction with a chiller, pipe the boiler and chiller in parallel as  
shown in Figure 9.11. Use isolation valves to prevent chilled water from entering the boiler.  
3) Air Handlers - Where the boiler is connected to air handlers through which refrigerated air passes, use ow control  
valves in the boiler piping or other automatic means to prevent gravity circulation during the cooling cycle.  
51  
X Wiring  
WARNING  
All wiring and grounding must be done in accordance with the authority having jurisdiction or, in  
the absence of such requirements, with the National Electrical Code (ANSI/NFPA 70).  
1) Line Voltage (120 VAC) Connections (Fig 10.1) – The line voltage connections are located in the junction box  
on the right side of the vestibule:  
Black – Line voltage “hot”  
White – “Neutral” for boiler and circulators  
Red – “Heating” circulator “hot”  
Blue – “Indirect Water Heater “ circulator “hot”  
Green – Ground connection  
2) Maximum circulator continuous current draw is 2A. When Piping Method #1 is used, it may be desirable to  
use the boiler to directly control the primary circulator in addition to the secondary circulator. If this is done,  
control both heating circulators using a relay with a 120VAC coil, such as a Honeywell R4222, as shown in  
Figure 10.3. Select a relay with a contact rating in excess of the combined draw of the two circulators.  
3) Low Voltage Connections (Fig 10.1) – These connections are screw terminals located on the terminal strip  
next to the junction box on the left:  
Terminals 1 and 2 – “Heating” thermostat connections  
Terminals 3 and 4 – “External Limit Control” connections  
Terminals 5 and 6 – “Outdoor Reset Sensor” connections  
Terminals 7 and 8 – “Domestic Indirect Water Heater” thermostat connections  
Terminal 9 – “Flame Signal Reading”  
Heat anticipator setting for the thermostat connection is 0.1 A when thermostat is connected directly to  
terminals 1 and 2.  
CAUTION  
WHEN MAKING LOW VOLTAGE CONNECTIONS, MAKE SURE THAT NO  
EXTERNAL POWER SOURCE IS PRESENT IN THE THERMOSTAT OR LIMIT  
CIRCUITS. IF SUCH A POWER SOURCE IS PRESENT, IT COULD DESTROY  
THE BOILER’S MICROPROCESSOR CONTROL (MCBA). ONE EXAMPLE OF  
AN EXTERNAL POWER SOURCE THAT COULD BE INADVERTENTLY CON-  
NECTED TO THE LOW VOLTAGE CONNECTIONS IS A TRANSFORMER IN  
OLD THERMOSTAT WIRING.  
4) If the outdoor sensor is connected to terminals 5 and 6, the boiler will adjust the target space heating set point  
supply water temperature downwards as the outdoor air temperature increases. If used, this sensor should be  
located on the outside of the structure in an area where it will sense the average air temperature around the  
house. Avoid placing this sensor in areas where it may be covered with ice or snow. In general, locations  
where the sensor will pick up direct radiation from the sun should also be avoided. Avoid placing the sensor  
near potential sources of electrical noise such as transformers, power lines, and uorescent lighting. Wire the  
sensor to the boiler using 22 gauge or larger wire. As with the sensor, the sensor wiring should be routed away  
from sources of electrical noise. Where it is impossible to avoid such noise sources, wire the sensor using a  
2 conductor, UL Type CM, AWM Style 2092, 300Volt 60°C shielded cable. Connect one end of the shielding  
on this cable to ground.  
53  
XI Start-up and Checkout  
NOTE  
SAFE LIGHTING AND OTHER PERFORMANCE CRITERIA WERE MET WITH THE GAS TRAIN  
ASSEMBLY PROVIDED ON THE BOILER WHEN THE BOILER UNDERWENT THE TEST  
SPECIFIED IN Z21.13.  
Use the following procedure for initial start-up of the boiler:  
1) If not already done, ush the system to remove sediment, ux, and traces of boiler additives. This should be  
done with the boiler isolated from the system.  
2) Fill the boiler and hydronic system with water meeting the following requirements below (also see the note on  
the next page):  
pH between 6.5 and 8.5  
Total Solids less than 2500 PPM  
Hardness less than 120 PPM (7 Grains/Gallon)  
Pressurize the system to at least 12 psi at the boiler  
WARNING  
NEVER ATTEMPT TO FILLA HOT EMPTY BOILER  
3) Check all new piping for leaks and purge piping sections that are lled with air. See the National Fuel Gas  
Code for additional information on testing and purging gas lines.  
WARNING  
NEVER USE A FLAME TO CHECK FOR GAS LEAKS.  
MAKE SURE THAT THE AREAAROUND THE BOILER IS CLEAR AND FREE FROM  
COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND  
LIQUIDS.  
4) Vent system must be complete and free of obstructions before attempting to re boiler. Make sure that the  
silicone cure time called for in the vent assembly instructions has passed before ring boiler.  
5) Inspect all line voltage wiring for loose or uninsulated connections.  
6) Remove the dust cap from the condensate trap (Fig 7.21). Add water to the trap until water runs out the con-  
densate drain. Reinstall the dust cap.  
57  
BWC Series Lighting and Operating Instructions  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING: If you do not follow these instructions exactly, a fire or explosion may  
result causing property damage, personal injury or loss of life.  
A. This appliance does not have a pilot. It is  
If you cannot reach your gas supplier, call the  
fire department.  
equipped with an ignition device which  
automatically lights the burner. Do not try  
to light the burner by hand.  
C. Use only your hand to turn the gas control knob.  
Never use tools. If the knob will not push in or turn by  
hand, don't try to repair it, call a qualified service  
technician. Force or attempted repair may result in a  
fire or explosion.  
B. BEFORE OPERATING smell all around the  
appliance area for gas. Be sure to smell  
next to the floor because some gas is  
heavier than air and will settle on the floor.  
D. Do not use this appliance if any part has been under  
water. Immediately call a qualified service technician  
to inspect the appliance and to replace any part of the  
control system and any gas control which has been  
under water.  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any appliance.  
Do not touch any electric switch; do  
not use any phone in your building.  
Immediately call your gas supplier  
from a neighbor's phone. Follow the  
gas supplier's instructions.  
OPERATING INSTRUCTIONS  
1. STOP! Read the safety information above on  
this label.  
6. Turn the external boiler manual gas valve T-  
handle counterclockwise to open gas supply.  
2. Set the thermostat to the lowest setting.  
3. Turn off all electric power to the appliance.  
7. Smell for gas in the boiler enclosure. If you smell gas,  
STOP! Follow "B" in the safety information above. If  
you don't smell gas, go to the next step.  
4. This appliance is equipped with an ignition  
device which automatically lights the burner.  
Do not try to light the burner by hand.  
8. Turn on all electric power to the appliance.  
9. Set the thermostat to the desired setting.  
5. Remove the front door panel and the upper  
boiler access panel.  
10. The first digit of the control display panel will  
show a series of numbers that indicate the boiler  
control sequence. The number 3 or 4 means the  
burner is firing. The number 0 means there is no  
call for heat from the thermostat or the domestic  
water heater.  
11. If the appliance will not operate, follow the  
instructions "To Turn Off Gas To Appliance" below  
and call your service technician or gas supplier.  
12. Replace the upper boiler access panel and the front  
door panel.  
TO TURN OFF GAS TO THE APPLIANCE  
1. Turn off all electric power to the appliance if  
service is to be performed.  
3. Turn the external boiler manual gas valve T-  
handle clockwise to close the gas supply.  
2. Set the thermostat to the lowest setting.  
4. Replace the upper boiler access panel and the front  
door panel.  
59  
WARNING  
EACH BWC SERIES BOILER IS TESTED AT THE FACTORY AND ADJUSTMENTS TO  
THE AIR-FUEL MIXTURE ARE NORMALLY NOT NECESSARY. CONSULT A CROWN  
REPRESENTATIVE BEFORE ATTEMPTING TO MAKE ANY SUCH ADJUSTMENTS. IM-  
PROPER GAS VALVE OR MIXTURE ADJUSTMENTS COULD RESULT IN PROPERTY  
DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.  
12) Test any external limits or other controls in accordance with the manufacturer’s instructions.  
13) Verify that the boiler starts and stops in response to calls for heat from the heating thermostat and indirect wa-  
ter heater thermostat. Make sure that the appropriate circulators also start and stop in response to the thermostats.  
14) As shipped, the heating and indirect water heater set point supply temperatures are both set to 180°F. If neces-  
sary, adjust these to the appropriate settings for the type of system to which this boiler is connected. See the Opera-  
tion section of this manual for information on how to do this.  
15) Adjust the heating and indirect water heater thermostats to their nal set points.  
62  
In standby mode, it is possible to view both the heating supply set point temperature and the “domestic hot water  
reference set point”. The “domestic hot water reference set point” plus 45°F equals the boiler supply set point when  
it is responding to a call from the indirect water zone. It is not the actual domestic hot water set point. The BWC  
is designed for use with a storage type indirect water heater such as the Crown Mega-Stor. The domestic water set  
point is controlled by the thermostat on the indirect water heater. The “default domestic water reference set point”  
is 135°F and target boiler supply temperature when responding to a call from the indirect water heater is therefore  
180°F (135°F +45°F). The default heating supply set point (parameter 4) is 180°F.  
In standby mode it is also possible to turn on or off either the heating or domestic water zone. There is normally no  
reason to turn off either of these zones and doing so is not recommended.  
CAUTION  
PUSHING AND HOLDING THE “+” WHILE IN STANDBY MODE WILL PREVENT THE BOILER  
FROM RESPONDING TO A CALL FOR HEAT. PUSHING AND HOLDING THE “-” WHILE IN  
STANDBY MODE WILL PREVENT THE BOILER FROM RESPONDING TO A CALL FOR DO-  
MESTIC WATER. IF THIS HAPPENS, “cOFF” or “dOFF” WILL APPEAR ON THE DISPLAY. TO  
TURN BACK ON THE HEATING FUNCTION, PRESS AND HOLD “+” UNTIL “c” AND THE SET  
POINT TEMPERATURE APPEARS ON THE DISPLAY. TO TURN BACK ON THE DOMESTIC  
WATER FUNCTION, PRESS AND HOLD “-” UNTIL “d” AND THE SET POINT TEMPERATURE  
APPEARS ON THE DISPLAY. AFTER PRESSING ANY KEYS, AND BEFORE LEAVING THE IN-  
STALLATION, VERIFY THAT THE BOILER FIRES IN RESPONSE TO A CALL FOR HEAT AND  
DOMESTIC WATER.  
In standby mode, if “Mode” and either “+” or “-“are simultaneously pushed and held for at least 2 seconds, the  
burner can be forced into either high or low re. This feature is used for running combustion tests. After 15 minutes,  
the burner will automatically revert to modulation. If it is desired to revert to modulation before 15 minutes has  
passed, simultaneously pushing “+” and “-“ will restore modulation.  
In Parameter mode both set points can be changed and both zones turned on or off. In addition, both zones can be  
congured for continuous pump operation. If the heating zone is set for continuous pump operation (parameter 3 set  
to 3), the heating pump will still shut down when there is a call for domestic hot water.  
If either the heating supply set point (parameter 4) , or the DHW reference set point (parameter 1) are set above  
their factory set values, the boiler supply temperature will exceed 180°F and there is a possibility that the safety  
temperature limit will open. If this happens, the boiler will shut down and a “b26” error will appear on the display.  
The boiler will resume normal operation without manual intervention when the safety limit closes (this behavior is  
common on conventional boilers).  
Information mode is used to view various temperatures and settings but cannot be used to change parameters or  
otherwise control the boiler. The information available is shown in Figure 12.2 and is largely self-explanatory. The  
digit to the left of the decimal point is the Step number and the digits to the right are the corresponding temperature.  
In information mode, the “supply water temperature set point” (Step 6) is the supply temperature set point for the  
zone to which the boiler is currently responding (either heat or DHW). If an outdoor sensor is connected to the  
boiler, and the boiler is responding to a call for heat, this value will be the current point on the reset curve. When no  
call for heat or DHW is present, Step 6 shows the heating supply set point.  
In some cases a “-22” will appear in Information Mode for a particular reading. This means that the reading is not  
applicable. For example, “-22” will appear for the outdoor temperature (Step 4) if no outdoor sensor is connected to  
the boiler.  
64  
Figure 12.4: Outdoor Reset Curve  
7) The sequence of operation for a BWC series boiler on a call for heat from a thermostat is as described below:  
a) When power is rst turned on, 120V is provided to the MCBA, the combustion fan and the LWCO trans-  
former. A separate 50VA transformer, connected directly to the MCBA, powers all other low voltage circuits.  
b) For the rst few seconds after power-up the control module goes through a self check.  
c) When there is a call for heat, the control module checks to make sure the air pressure switch is open. If it is, the  
combustion fan will be energized and will ramp up to ignition speed. When the air pressure switch closes, a 10  
second prepurge is activated.  
d) After the prepurge, the control module energizes the gas control valve and the spark for 4.5 seconds. If a  
ame is established and proved, the control allows the ame to stabilize for 5 seconds at the combustion fan  
ignition speed setting. If the ame fails to prove, the control module will attempt to light the burner 4 more  
times. If a ame is still not established, the control will lockout.  
e) Once the ame stabilization period has ended, the MCBA allows the burner to modulate. The actual ring rate  
is dependent upon the measured current and recent differences between the set point temperature and the supply  
temperature. If an outdoor sensor is connected to the control module and the boiler is responding to a call for  
heat, the set point temperature will be determined by the outdoor reset curve shown in Figure 12.4.  
f) Once the set point temperature is reached, the MCBA will turn the burner off and allow the combustion fan to  
operate in postpurge for 35 seconds before it turns off.  
g) The central heating pump will continue to operate until the room thermostat has been satised.  
h) Ademand for domestic hot water (DHW) is given priority on BWC series boilers. If a call for DHW is received  
while the boiler is responding to a call for heat, the heating circulator is deenergized until the call for DHW is  
satised.  
67  
XIII. Service and Maintenance  
IMPORTANT  
WARRANTY DOES NOT COVER BOILER DAMAGE OR MALFUNCTION IF THE FOL-  
LOWING STEPS ARE NOT PERFORMED AT THE INTERVALS SPECIFIED.  
1) Continuously:  
a. Keep the area around the boiler free from combustible materials, gasoline and other  
ammable vapors and liquids.  
b. Keep the area around the combustion air inlet terminal free from contaminates.  
c. Keep the boiler room ventilation openings open and unobstructed.  
2) Monthly Inspections:  
a. Inspect the vent piping and outside air intake piping to verify they are open, unobstructed and free  
from leakage or deterioration. Call the service technician to make repairs if needed.  
b. Inspect the condensate drain system to verify it is leak tight, open and unobstructed. Call the service  
technician if the condensate drain system requires maintenance.  
c. Inspect the water and gas lines to verify they are free from leaks. Call the service technician to make  
repairs if required.  
CAUTION  
WATER LEAKS CAN CAUSE SEVERE CORROSION DAMAGE TO THE BOILER OR  
OTHER SYSTEM COMPONENTS. IMMEDIATELY REPAIR ANY LEAKS FOUND.  
4) Annual Inspections and Service: In addition to the inspections listed above, the following should be per-  
formed by a service technician once every year.  
a. Test the low water cutoff by pressing the “Test” button located at its end. The yellow light should  
come on and “E12” should ash on the display. Push the reset button on the display to restore normal  
operation. If the yellow light does not come on, determine why the low water cutoff is not working  
properly.  
b. Follow the procedure for turning the boiler off found in the BWC Series Lighting and Operating  
Instructions.  
c. Inspect the wiring to verify the conductors are in good condition and attached securely.  
CAUTION  
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.  
WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY  
PROPER OPERATION AFTER SERVICING.  
68  
d.  
e.  
Remove the ignition electrode and inspect it for oxides. Clean the oxides off the electrode with  
sandpaper. Inspect the ceramic insulator for cracks and replace the ignitor assembly if necessary.  
Remove the fan/gas valve assembly from the burner hood. Inspect for lint and dust. If signicant lint  
and dust are found, disassemble the fan/gas valve assembly to expose the swirlplate and fan inlet (see  
the exploded diagram in the parts list at the back of this manual). Vacuum these parts as required,  
being careful not to damage the vanes on the swirlplate.  
Remove the burner hood to access the burner and the combustion chamber.  
Remove the burner and vacuum any dust or lint from the burner. If the burner shows signs of  
deterioration or corrosion, replace it immediately. Inspect the burner gasket and replace, if necessary.  
Inspect the heat exchanger and vacuum any debris found on the pins and other surfaces. Clean the  
casting pins by ushing with clean water. A soft nylon brush may be used in accessible areas. Drain  
and ush the inside of the heat exchanger and condensate collector as required. Do not use any  
cleaning agents or solvents.  
Inspect the condensate trap to verify it is open and free from debris. Clean if necessary.  
Reinstall the burner, burner hood and fan/gas valve assembly.  
Reconnect any wiring which has been disconnected.  
Inspect the heating system and correct any other deciencies prior to restarting the boiler.  
Follow Section XI Start-up and Checkout instructions before leaving installation.  
Perform the combustion test outlined in Section XI.  
Verify that the system PH is between 6.5 and 8.5.  
Check for vent terminal obstructions and clean as necessary.  
f.  
g.  
h.  
i.  
j.  
k.  
l.  
m.  
n.  
o.  
p.  
69  
B. Trouble shooting problems where a soft lockout code is displayed. When a soft lockout occurs, the boiler will  
shut down and the display will alternate between the number “9” and the letter “b” followed by a two digit  
service code. The boiler will automatically restart once the condition that caused the lockout is corrected.  
Table 14.3: Soft Lockout Codes Displayed  
CODE  
CONDITION  
POSSIBLE CAUSES  
• Blockage in intake or vent system.  
• Vent and/or intake system not constructed in accordance  
with Part VII.  
b 08  
Pressure switch circuit open.  
• Blocked or leaking pressure switch tubing.  
• Heat exchanger or burner blockage.  
Terminals exposed to high winds.  
• Blockage in condensate trap above vent.  
• Heating load at time of error was far below the minimum  
ring rate of the boiler.  
MCBA supply sensor detected temperatures in excess  
of 200°F.  
• Defective primary pump or no ow in primary loop (Piping  
Method 1).  
• Control system miswired so that boiler operation is  
permitted when no zones are calling.  
b 18  
b 19  
MCBA return sensor detected temperatures in excess of  
200°F.  
• See possible causes for “b18”.  
• Flow through boiler reversed.  
• Sensor wiring reversed.  
• Flow through boiler reversed. Verify correct piping and  
pump orientation.  
• No boiler water ow. Verify that system is purged of air  
and that appropriate valves are open.  
• Sensor wiring reversed.  
MCBA is reading a return sensor temperature higher  
than the supply sensor temperature. Condition must be  
present for at least 75s for this error code to appear.  
b 24  
b 25  
• Supply or return sensor defective.  
• See possible causes for “b18”.  
• Inadequate boiler water ow. Verify that pump is  
operating and that pump and piping are sized per Part IX  
of this manual.  
Supply water temperature has risen too quickly.  
Boiler safety limit, or external limit wired across terminals  
3&4, is open.  
• See possible causes for “b18”.  
• Defective supply sensor.  
b 26  
b 30  
• Inadequate boiler water ow. Verify that pump is  
operating and that pump and piping are sized per Part IX  
of this manual.  
Temperature rise between supply and return is too high.  
• Blockage in pressure switch hose.  
• Pressure switch wires shorted together.  
• Defective pressure switch.  
• Loose or miswired fan speed harness (if “b61” error code  
is observed while fan is running).  
b 61  
b 65  
Pressure switch circuit closed with fan off.  
Fan is not achieving set point speed.  
• Loose or incorrect fan speed control connection.  
• Defective fan.  
71  
XV Parts  
The following parts may be obtained from any Crown distributor. To nd the closest Crown distributor, consult the  
area Crown representative or the factory at:  
Crown Boiler Co.  
Customer Service  
P.O. Box 14818  
Philadelphia, PA 19134  
73  

Alpine CVA 1003 User Manual
Attwood 4030 User Manual
Audiovox P 945 User Manual
Boss Audio Systems Car Stereo System 610C User Manual
BUSH Eclipse Digital Radio 1300 055 518 User Manual
Dynex DX SW040 User Manual
Hitachi Camcorder E521A User Manual
Honda Automobiles 2005 Accord Hybrid User Manual
HP (Hewlett Packard) Photosmart 6221 User Manual
JVC GR SXM257 User Manual