| Split System   Cooling   Product Data   XL16i   4TTX6024, 036, 048 & 060E   2, 3, 4 & 5 Tons   PUB. NO. 22-1752-10   Contents   features and Benefits   2 General Data   4 4 4 5 5 Product Specifications   A-weighted Sound Power Level [dB(A)]   Accessory Description and Usage   AHRI Standard Capacity Rating Conditions   model Nomenclature   Electrical Data   6 7 8 9 Dimensions   mechanical Specifications   22-1752-10   3 General   Data   Product Specifications   Model No. 1   4TTX6024E1   4TTX6036E1   4TTX6048E1   4TTX6060E1   Electrical Data V/Ph/Hz 2   Min Cir Ampacity   Max Fuse Size (Amps)   230/1/60   14   20   230/1/60   22   35   230/1/60   29   50   230/1/60   39   60   Compressor   CLIMATUFF® - SCROLL   CLIMATUFF® - SCROLL   CLIMATUFF® - SCROLL   CLIMATUFF® - SCROLL   RL AMPS - LR AMPS   Outdoor Fan FL Amps   Fan HP   10.3 - 52   0.74   1/8   16.7 - 82   0.74   1/8   21.2 - 104   2.80   1/3   28.8 - 152.9   2.80   1/3   Fan Dia (inches)   27.6   27.6   27.6   27.6   Coil   Spine Fin™   9/13-LB/OZ   5/8   Spine Fin™   9/13-LB/OZ   3/4   Spine Fin™   12/9-LB/OZ   7/8   Spine Fin™   12/9-LB/OZ   1-1/8   Refrigerant R-410A   Line Size - (in.) O.D. Gas 3   Line Size - (in.) O.D. Liquid 3   3/8   3/8   3/8   3/8   Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7   57.4 x 35.1 x 38.7   57.4 x 35.1 x 38.7   57.4 x 35.1 x 38.7   Weight - Shipping   Weight - Net   309   261   316   266   328   291   332   295   Start Components   Sound Enclosure   Compressor Sump Heat   NO   NO   NO   NO   NO   NO   NO   NO   NO   NO   NO   NO   Optional Accessories: 4   Rubber Isolator Kit   Snow Leg - Base & Cap 4" High   Snow Leg - 4" Extension   Hard Start Kit Scroll   BAYISLT101   BAYLEGS002   BAYLEGS003   BAYKSKT260   BAYCCHT301   BAYECMT023   BAYVDTA003   BAYCAKT001   TAYREFLN9*   BAYISLT101   BAYLEGS002   BAYLEGS003   BAYKSKT260   BAYCCHT301   BAYECMT004   BAYVDTA004   BAYCAKT001   TAYREFLN7*   BAYISLT101   BAYLEGS002   BAYLEGS003   BAYKSKT260   BAYCCHT301   BAYECMT004   BAYVDTA004   BAYCAKT001   TAYREFLN3*   BAYISLT101   BAYLEGS002   BAYLEGS003   BAYKSKT260   BAYCCHT301   BAYECMT004   BAYVDTA004   BAYCAKT001   TAYREFLN4*   Crankcase Heater Kit   Extreme Condition Mounting Kit   Vertical Discharge Air Kit Base 4   Auto Charge Solenoid Kit   Refrigerant Lineset 5   1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.   2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.   3 Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line.   For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision)   4 For accessory description and usage, see page 5.   5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.   A-weighted Sound Power Level [dB(A)]   SOUND POWER   LEVEL [dB(A)]   A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]   MODEL   63   125   250   500   1000   2000   4000   8000   4TTX6024E   4TTX6036E   4TTX6048E   4TTX6060E   72   72   73   74   43.7   52.6   54.3   62.4   60.4   57   54.1   46.6   38   50.4   50.4   53.8   56.8   58.9   57.8   60.4   63.1   66   59.8   63   57.2   57.4   57.7   55.2   53.6   58.4   49.2   47.4   51.7   44.2   42.2   65.7   Note: Rated in accordance with AHRI Standard 270-2008.   4 22-1752-10   General   Data   accessory Description and Usage   ahRi Standard Capacity Rating Conditions   ahRi STaNDaRD 210/240 RaTiNG CONDiTiONS —   (A) Cooling 80°F DB, 67°F WB air entering indoor coil,   95°F DB air entering outdoor coil.   (B) High Temperature Heating 47°F DB, 43°F WB air entering   outdoor coil, 70°F DB air entering indoor coil.   (C) Low Temperature Heating 17°F DB, 15°F WB air entering   outdoor coil, 70°F DB air entering indoor coil.   Rubber isolators — 5 rubber donuts to isolate condens-   ing unit from mounting frame or pad. Use on any application   where sound transmission needs to be minimized.   Extreme Conditions mounting kit — Bracket kits to secure-   ly mount condensing unit to a frame or pad without removing   any panels. Use in areas with high winds, or on commercial   rooftops, etc.   (D) Rated indoor airflow for heating is the same as for cooling.   Low ambient Cooling — For low ambient cooling below 55°   see Application Guide APP-APG013-EN.   ahRi STaNDaRD 270 RaTiNG CONDiTiONS — (Noise   rating numbers are determined with the unit in cooling opera-   tion.) Standard Noise Rating number is at 95°F outdoor air.   22-1752-10   5 Model   Nomenclature   T U D 2 B 0 8 0 A C V 3 2 A A 4 T   T X 6 0 3 6 E 1 0 0 0 A   A Gas Furnaces   Outdoor Units   Refrigerant Type   4 = R-410A   TRANE   Product Type   W = Split Heat Pump   T = Split Cooling   Product Family   Z = Leadership – Two Stage   X = Leadership   R = Replacement/Retail   M or B = Basic   A = Light Commercial   Family SEER   3 = 13   4 = 14   5 = 15   6 = 16   8 = 18   9 = 19   0 = 20   Split System Connections 1-6 Tons   0 = Brazed   Nominal Capacity in 000s of BTUs   Major Design Modifications   Power Supply   1 = 200-230/1/60 or 208-230/1/60   3 = 200-230/3/60   4 = 460/3/60   Secondary Function   Minor Design Modifications   Unit Parts Identifier   4 T X C B 0 0 1 C C 3 H C A A 4 T E E 3 F 3 6 A 1 0 0 0 A A Coils –   Air Handlers –   Residential   Residential   RefrigerantType   Refrigerant Type   4 - R410A   4 = R-410A   Product Family   T-Premium   (HeatPumporConvertibleCoil)   Application   TE = Fully Convertible   TG = Semi Convertible   TF = Front Return   Coil Design   X - Direct Expansion Evaporator Coil   Product Family   C - Cased A Coil   Product Family   E = Leadership – Variable Speed   P = Leadership   A - Uncased A Coil   F - Cased Horizontal Flat Coil   C = Replacement/Retail   B = Basic   CoilWidth(Cased/Uncased)   A - 14.5" / 13.3"   B - 17.5" / 16.3"   C - 21.0" / 19.8"   D - 24.5" / 23.3"   H - 10.5"   Flow Control   0 = No Flow Control   3 = Nonbleed TXV   RefrigerantLineCoupling   Feature Identifier   0 = Standard Unit   F = Air-Tite™   0 - Brazed   ModelNumberDistinguisher   MajorDesignChange   Nominal Capacity in 1000’s (BTUH)   Major Design Change   Efficiency   C - Standard   Power Supply   1 = Single Phase   S - Hi Efficiency (Derived from 10 SEER products)   RefrigerantControl   Electrical Connection   0 = Pig Tails   B = Circuit Breaker   D = Pull Disconnect   3 - TXV - Non-Bleed   Coil Circuitry   H - Heat Pump   AirflowConfiguration   A - Upflow Only   Future Option – Factory Installed Heater Nominal KW Value   Minor Design Modifications   U - Upflow / Downflow   H - Horizontal Only   Unit Parts Identifier   C - Convertible - Upflow, Downflow, Left or Right Airflow   NOTE: There will be a phase-in of new model numbers for new   air handlers over next 2 years.   MinorDesignChange   UnitPartsIdentifier   6 22-1752-10   Electrical   Data   Schematic Diagrams   (SEE LEGEND)   4TTX6024E, 036E   Printed from D156630P02 Rev 00   22-1752-10   7 Electrical   Data   Schematic Diagrams   (SEE LEGEND)   4TTX6048E, 060E   8 22-1752-10   Electrical   Data   Schematic Diagrams   LEGEND   22-1752-10   9 Dimensions   4TTX6 Outline Drawing   Note: all dimensions are in mm (inches).   mODELS   BaSE   a B C D E f G h J k 4TTX6024E   4TTX6036E   4TTX6048E   4TTX6060E   4 4 4 4 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4)   1369 (53-7/8) 946 (37-1/4) 870 (34-1/4)   1369 (53-7/8) 946 (37-1/4) 870 (34-1/4)   5/8   3/4   7/8   3/8   3/8   3/8   152 (6)   152 (6)   152 (6)   152 (6)   98 (3-7/8) 219 (8-5/8) 86 (3-3/8)   730 (28-3/4)   98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 1035 (40-3/4)   98 (3-7/8) 219 (8-5/8) 86 (3-3/8)   98 (3-7/8) 219 (8-5/8) 86 (3-3/8)   730 (28-3/4)   730 (28-3/4)   1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8   From Dwg. D152635 Rev. 16   22-1752-10   10   Mechanical   Specifications   General   Condenser Coil   The 4TTX6 is fully charged from the fac-   tory for matched indoor section and up   to 15 feet of piping. This unit is designed   to operate at outdoor ambient tempera-   tures as high as 115°F. Cooling capaci-   ties are matched with a wide selection   of air handlers and furnace coils that are   AHRI certified. The unit shall be certi-   fied to UL 1995. Exterior is designed for   outdoor application.   The outdoor coil provides low airflow   resistance and efficient heat transfer.   The coil is protected on all four sides by   louvered panels.   Low ambient Cooling   As manufactured, this unit has a cool-   ing capability to 55°F. For low ambient   cooling below 55° see Application Guide   APP-APG013-EN.   Casing   Unit casing is constructed of heavy   gauge, G60 galvanized steel and   painted with a weather-resistant powder   paint on all louvers and panels. Cor-   rosion and weatherproof CMBP-G30   DuraTuff™ base.   Refrigerant Controls   Refrigeration system controls include   condenser fan, compressor contactor   and high pressure switch. High and low   pressure controls are inherent to the   compressor. A factory installed liquid line   drier is standard.   Compressor   The Climatuff® 2-stage compressor   features internal over temperature and   pressure protection and hermetic motor.   Other features include: roto lock suction   and discharge refrigerant connections,   centrifugal oil pump and modular plugs   for electrical connections.   22-1752-10   11   10/10   Trane   Trane has a policy of continuous product and product data improvement and it reserves the right to change   design and specifications without notice.   |