| SANYO AIR CONDITIONING PRODUCTS   DUCTLESS SPLIT SYSTEM AIR CONDITIONERS & HEAT PUMPS   SPECIFICATIONS - SECTION 15700   Covers Sanyo System Models > 42TS32A, 42TLS32A (See plans for specified models & details)   DUCTLESS SPLIT SYSTEM AIR CONDITIONERS – SUSPENDED CEILING TYPE   1) GENERAL SPECIFICATIONS   Furnish & install a Sanyo manufactured Ductless, Split System Air Conditioner(s) consisting of a   suspended ceiling type indoor mounted evaporator/blower section & matching outdoor condensing   section. System(s) shall bear the ARI label showing that the system(s) is ARI 210 or 240 & 270   Certified. Systems shall be listed by ETL Testing Laboratories and bear the ETL label. Matching   systems shall meet or exceed the minimum, Federally mandated Seasonal Energy Efficiency   Rating (SEER) of 10, and Heating Seasonal Performance Factor (HSPF) of 6.8 (heat pump(s)   only) as certified by the ARI testing programs. System(s) indoor & outdoor units will operate at   sound levels equal to or below specified system(s) (see plans). Installation & Owners Manuals   shall be provided with each system.   Matching indoor & outdoor sections shall be connected by deoxidized, annealed refrigerant copper   tubing, type “L”, cleaned & capped. All systems shall have flared refrigeration connections on   both indoor & outdoor sections. Size & insulate tubing according to manufacturer’s specifications.   System(s) indoor & outdoor sections shall be completely factory assembled & wired, with a pre-   charge of refrigerant. A single power source shall provide voltage to both the outdoor & indoor   units. Electrical wire & connections to outdoor section, and between indoor & outdoor section(s),   shall be sized, installed & grounded by the installer in conformance with the National Electrical   Code (N.E.C.), local codes, as well as, manufacturer’s instructions.   System(s) shall be equipped with a microprocessor control system, utilizing an infrared remote   controller with LCD display that provides access to all system functions, and transmits room   conditions & programs to the indoor microprocessor every 3 minutes. Infrared remote controller   shall be capable of operating system mounted up to 26’ from the indoor section, according to   manufacturer’s recommendations & instructions. System(s) shall have the capability of continuous   operation in the case of a lost or damaged remote controller, utilizing a factory installed, integral   manual switch in conjunction with the system microprocessor.   1A) System Infrared Remote Controller Functions will include: system mode selection,   programmable temperature control, 24 hour programmable timer, one (1) hour off timer,   automatic three (3) speed indoor fan speed control, constant fan speed selection, night setback   mode, automatic sweep/flap control, user selectable room temperature sensor located on either   infrared remote controller or indoor unit, multiple system control using a single controller.   1B) System Features will include: Copeland high efficiency, scroll compressor, with a suction   line accumulator, liquid sub-cooler, a liquid line strainer, cap tube refrigerant control, indoor coil   -1-   protection, permanent lubrication & multi-speed capability. Unit(s) shall contain a Printed Circuit   Board (PCB) with a control circuit fuse & microprocessor, factory wired & mounted, that receives   & processes all commands & transmissions from the system Infrared Remote Controller. Indoor   unit(s) shall also contain an Operation Switch with visible lamps for operation, standby & timer   functions, as well as, a system test switch & a manual ON/OFF switch. Unit(s) shall contain a   room sensor thermistor, a liquid line strainer, a coil freeze safety thermistor to prevent freeze-up, a   factory installed condensate drain pan, drain hose & fitting, and refrigeration line connections with   flare nuts. Unit(s) shall contain knockouts on both sides & the top of the casing that allow   refrigerant lines to be brought to the unit from multiple directions. Fresh Air knockouts shall be   provided on the back and top of the unit(s), to allow system(s) to utilize fresh, outside air up to a   maximum of 20% of the rated CFM of the system. A motorized louver/flap, controlled by the   infrared remote controller, shall provide automatic, full oscillating supply airflow, as well as being   capable of being placed in a set, stationary position. Unit(s) shall be furnished with 2,500 hour,   long-life anti-mold, poly type washable air filters that can be easily removed without removing   indoor unit casing. Indoor unit(s) shall be powered by voltage from the matching outdoor unit(s).   4) AVAILABLE SANYO ACCESSORIES – All Suspended Ceiling Mount Models   Insulated Copper Line Sets, , Outdoor Unit Wall Mounting   Bracket, Condensate Pumps, Hard Wired Remote Controller (straight cooling systems only).   -3-   |