Windsor Vacuum Cleaner 10070560 User Manual

Multi-Functional Cleaning  
MODEL: CMPS2  
10070560  
CMPS2E  
10070570  
Operating Instructions (ENG)  
86305210 –F  
02/19/09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Machine Data Log/Overview.........................2  
Table of Contents..........................................3  
GROUP PARTS LIST  
Control Panel................................................5-1  
Decal.............................................................5-3  
Solution Tank................................................5-5  
Solution-Injector Assembly ...........................5-7  
Solution-Pump ..............................................5-9  
Recovery Tank............................................ 5-13  
Vacuum....................................................... 5-15  
Wheels & Frame ........................................ 5-17  
Tools – Standard ........................................ 5-19  
Wiring – Schematic (120V)......................... 5-21  
Wiring – Schematic (230V)......................... 5-23  
Suggested Spare Parts............................... 5-23  
HOW TO USE THIS MANUAL  
How to use this Manual.................................1-1  
SAFETY  
Important Safety Instructions ........................2-1  
Hazard Intensity Level. .................................2-2  
Grounding Instructions..................................2-3  
Safety Label Location. ..................................2-4  
OPERATIONS  
OPTIONS  
Technical Specifications. ..............................3-1  
How the Machine Works...............................3-2  
Components..................................................3-3  
Controls.........................................................3-4  
Machine Operation........................................3-6  
Chemicals .....................................................3-8  
Vacuum Hose Rack.................................... 6-1  
Grout Cleaner ............................................. 6-3  
High Pressure Wand................................... 6-5  
Carpet Tool................................................. 6-7  
Storage Bag................................................ 6-9  
Chemical Lock ............................................ 6-11  
Serial Numbers........................................... 6-13  
Warranty  
MAINTENANCE  
Maintenance. ................................................4-1  
Float Shut-Off..........................................4-2  
Strainer....................................................4-2  
Circuit Breakers.......................................4-2  
Vacuum Motor Replacement...................4-3  
Solution Pump Replacement...................4-4  
Regulating Unloader…………………….. 4-4  
Periodic/Daily Maintenance ..........................4-5  
Service Schedule..........................................4-5  
Machine Troubleshooting..............................4-6  
Notes.............................................................4-7  
CMPS2 86305210 04/28/08  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO USE THIS MANUAL  
The SAFETY section contains important information  
regarding hazard or unsafe practices of the  
machine. Levels of hazards is identified that could  
result in product or personal injury, or severe injury  
resulting in death.  
This manual contains the following sections:  
-
-
-
HOW TO USE THIS MANUAL  
SAFETY  
OPERATIONS  
The OPERATIONS section is to familiarize the  
operator with the operation and function of the  
machine.  
-
-
MAINTENANCE  
PARTS LIST  
The HOW TO USE THIS MANUAL section will tell  
you how to find important information for ordering  
correct repair parts.  
The MAINTENANCE section contains preventive  
maintenance to keep the machine and its  
components in good working condition. They are  
listed in this general order:  
Parts may be ordered from authorized Windsor  
dealers. When placing an order for parts, the  
machine model and machine serial number are  
important. Refer to the MACHINE DATA box which  
is filled out during the installation of your machine.  
The MACHINE DATA box is located on the inside of  
the front cover of this manual.  
-
-
-
-
-
-
Vacuum Motor  
Solution Pump  
Daily Maintenance  
Periodic Maintenance  
Service Schedule  
Machine Troubleshooting  
The PARTS LIST section contains assembled parts  
illustrations and corresponding parts list. The parts  
lists include a number of columns of information:  
MODEL __________________________________  
DATE OF PURCHASE _____________________  
SERIAL NUMBER ________________________  
SALES REPRESENTATIVE # _______________  
-
-
REF – column refers to the reference  
number on the parts illustration.  
PART NO. – column lists the part  
number for the part.  
-
-
PRV NO. - reference number.  
QTY – column lists the quantity of the  
part used in that area of the machine.  
DESCRIPTION – column is a brief  
description of the part.  
The model and serial number of your machine is on  
the bottom back-end of the machine.  
-
-
SERIAL NO. FROM – If this column has  
an (*) and a Reference number, see the  
SERIAL NUMBERS page in the back of  
your manual. If column has two asterisk  
(**), call manufacturer for serial number.  
The serial number indicates the first  
machine the part number is applicable  
to. The main illustration shows the most  
current design of the machine. When a  
boxed illustration is shown, it displays  
the older design.  
-
NOTES – column for information not  
noted by the other columns.  
NOTE: If a service or option kit is installed  
on your machine, be sure to keep the  
KIT INSTRUCTIONS which came with  
the kit. It contains replacement parts  
numbers needed for ordering future  
parts.  
CMPS2 86305210 04/23/08  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
When using an electrical appliance, basic precaution  
must always be followed, including the following:  
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.  
This machine is for commercial use.  
To reduce the risk of fire, electric shock, or injury:  
Connect to a properly grounded outlet. See Grounding Instructions.  
Do not leave the machine unattended. Unplug machine from outlet when not in use and before  
maintenance or service.  
Do not allow machine to be used as a toy. Close attention is necessary when used by or near  
children.  
Do not point spray gun at people.  
Use only as described in this manual. Use only manufacturer’s recommended components and  
attachments.  
Do not use damaged electrical cord or plug. Follow all instructions in this manual concerning grounding  
the machine. If the machine is not working properly, has been dropped, damaged, left outdoors, or  
dropped into water, return it to an authorized service center.  
Do not pull or carry machine by electrical cord, use as a handle, close a door on cord, or pull cord  
around sharp edges or corners.  
Do not run machine over cord. Keep cord away from heated surfaces.  
Do not unplug machine by pulling on cord. To unplug, grasp the electrical plug, not the electrical cord.  
Do not handle the electrical plug or machine with wet hands.  
Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce  
airflow.  
Do not vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.  
This machine is not suitable for picking up health endangering dust.  
Turn off all controls before unplugging.  
Machine can cause a fire when operating near flammable vapors or materials. Do not operate this  
machine near flammable fluids, dust or vapors.  
This machine is suitable for commercial use, for example in hotels, schools, hospitals,  
factories, shops and offices for more than normal housekeeping purposes.  
Maintenance and repairs must be done by qualified personnel.  
If foam or liquid comes out of machine, switch off immediately.  
SAVE THESE INSTRUCTIONS  
CMPS2 86305210 11/21/07  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HAZARD INTENSITY LEVEL  
The following symbols are used throughout this guide as indicated in their descriptions:  
HAZARD INTENSITY LEVEL  
There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR  
SAFETY. The level of hazard intensity is determined by the following definitions:  
WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.  
CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property  
damage.  
FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.  
Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper  
operating condition. Following is information that signals some potentially dangerous conditions to the  
operator or the equipment. Read this information carefully. Know when these conditions can exist. Locate  
all safety devices on the machine. Please take the necessary steps to train the machine operating  
personnel.  
FOR SAFETY:  
DO NOT OPERATE MACHINE:  
Unless Trained and Authorized.  
Unless Operation Guide is Read and understood.  
In Flammable or Explosive areas.  
In areas with possible falling objects.  
WHEN SERVICING MACHINE:  
Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the  
machine. Use Windsor approved replacement parts.  
.
CMPS2 86305210 11/21/07  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GROUNDING INSTRUCTIONS  
THIS PRODUCT IS FOR COMMERCIAL USE  
ONLY.  
GROUND-FAULT CIRCUIT-INTERRUPTER  
PROTECTION (120V ONLY)  
This pressure washer is provided with a  
(GFCI) built into the plug of the power supply  
cord. This device provides additional protection  
from the risk of electric shock. Should  
ELECTRICAL:  
The amp, hertz, and voltage are listed on the data  
label found on each machine. Using voltages above  
or below those indicated on the data label will cause  
serious damage to the motors.  
replacement of the plug or cord become  
necessary, use only identical replacement parts  
that include GFCI protection. If the GFCI is not  
the AUTOMATIC RESET TYPE, it must be  
manually TESTED and RESET each time the  
cleaning system is plugged in. Press firmly to  
assure internal spring activates switch. Push  
“test“ then push “reset”. Motor will not start if  
GFCl does not reset. Check circuit breakers or  
outlet. If circuit breaker is not tripped and unit  
will not reset, contact local service center.  
EXTENSION CORDS:  
If an extension cord is used, the wire size must be at  
least one size larger than the power cord on the  
machine, and must be limited to 50 feet (15.5m) in  
length.  
GROUNDING INSTRUCTIONS:  
This appliance must be grounded. If it should  
malfunction or break down, grounding provides a  
path of least resistance for electric current to reduce  
the risk of electric shock. This appliance is equipped  
with a cord having an equipment-grounding  
conductor and grounding plug. The plug must be  
inserted into an appropriate outlet that is properly  
installed and grounded in accordance with all local  
codes and ordinances.  
Improper connection of the equipment-  
grounding conductor can result in a risk of  
electric shock. Check with a qualified electrician  
or service person if you are in doubt as to  
whether the outlet is properly grounded. Do not  
modify the plug provided with the appliance - if it  
will not fit the outlet, have a proper outlet  
installed by a qualified electrician.  
GROUNDING INSTRUCTIONS (120V ONLY)  
CMPS2 86305210 04/23/08  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY LABEL LOCATION  
The following WARNING LABEL(S) are found on your cleaning unit. These labels point out important Warnings  
and Cautions which should be followed at all times. Failure to follow warnings and cautions could result in fatality,  
personal injury to yourself and/or others, or property damage. Follow these instructions carefully! DO NOT  
remove these labels.  
NOTE: If at any time the labels become illegible, promptly replace them.  
WARNING LABEL 86242230  
PRV NO. 500009  
CMPS2 86305210 11/21/07  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TECHNICAL SPECIFICATIONS  
ITEM  
DIMENSION/CAPACITY  
120V, 14A, 60HZ  
Electrical  
230V, 7A, 50HZ  
Electric Pump Motor  
Solution Pump  
Electric Vacuum Motor  
Waterlift  
1/2hp, 1750rpm  
700psi (48 bars), Axial plunger  
2stage, 1.25hp (2.80m3/min.)  
82 in. (208 cm)  
Solution Capacity  
29 gallons (111L)  
Recovery Capacity  
Wheels  
19 gallons (70L)  
-
-
Front (2)  
Rear (2)  
6 in. dia. (15.24cm) X 1.5  
12 in. dia. ( 30.48cm)X 1.75  
205 lb. (93kg)  
36 in. (91.4cm)  
43 in. (109.2cm)  
Dimensions – Weight  
Dimensions – Length  
Dimensions - Height  
Dimensions - Width  
Power Cable  
24.75 in. (62.87cm)  
50 ft. (127m) 14 gauge  
SPECIAL NOTES:  
The sound pressure level at 1m from the machine was measured to be 79 dBA. This was a nearfield,  
broadband measurement taken in a typical industrial environment on a tile floor. This appliance  
contains no possible source of impact noise. The instantaneous sound pressure is below 63 Pa.  
The weighted root mean square acceleration at the operator’s arms was measured to be below  
2.5m/s2. This was a tri-axial, third-octave-band measurement made during normal operation on a  
composite tile floor. The measurement and related calculations were made in accordance with  
ISO 5349-1.  
CMPS2 86305210 04/23/08  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW THE MACHINE WORKS  
The Compass 2is a multi-functional cleaning  
machine intended for commercial use. The  
appliance applies chemical at low pressure and  
uses high pressure to clean with. Then the  
soiled water is vacuumed back into the  
recovery tank.  
The function of the chemical system is to  
dispense chemical into the clean water system.  
The chemical system consists of the chemical  
reservoir, chemical cap and a chemical-  
metering selector. The chemical reservoir  
stores and dispenses chemical into the clean  
water system. The chemical-metering selector  
meters the amount of chemical and selects  
between chemical A or B and turn chemical off.  
The machine's primary systems are the clean  
water system, recovery system, chemical  
system and pressure washer system.  
The function of pressure washer system is to  
clean fixtures and other surfaces. The pressure  
washer system consists of a pump, high-  
pressure hose and spray gun. The pump  
delivers cleaning solution to the tools. The  
high-pressure hose connects the pump to the  
spray gun.  
The function of the clean water system is to  
store clean water and deliver it to the available  
tools. The clean water system consists of the  
clean water tank and strainer. The clean water  
tank stores water until it is delivered to the  
tools. The strainer protects the pump from  
debris.  
The function of the recovery system is to  
vacuum the soiled water back into the recovery  
tank. The recovery system consists of the  
wand and wheeled squeegee, vacuum motor,  
float shut-off and recovery tank. The wand and  
wheeled squeegee wipes the dirty solution off  
the floor. The vacuum motor provides suction  
to draw the dirty solution off the floor and into  
the recovery tank. The float shut-off protects  
the vacuum fan from over filling. The recovery  
tank stores the dirty solution.  
CMPS2 86305210 11/21/07  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPONENTS  
9
7
1
5
11  
3
6
8
2
10  
4
1. Control Panel  
2. Solution Tank  
3. Solution Tank Lid  
4. Solution Tank Drain Hose  
5. Solution Tank Fill Hose  
6. Recovery Tank  
7. Recovery Tank Lid  
8. Recovery Tank Drain Hose  
9. Chemical Siphon Caps  
10. Electrical Cord  
11. High Pressure Hose Storage  
CMPS2 86305210 11/21/07  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROLS  
4
3
9
7
8
6
5
2
1
1. Caster Lock  
2. Chemical Selector and Metering Valve  
3. Pump Circuit Breaker  
5. Solution Accessory Tool Hook-Up  
6. Vacuum Accessory Tool Hook-Up  
7. Vacuum Circuit Breaker  
8. Vacuum Switch  
4. Pump Switch/Pump Chemical Switch  
9. Main Switch (230V only)  
CMPS2 86305210 04/23/08  
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROLS  
1. SOLUTION ACCESSORY TOOL HOOK-UP  
Used for various auxiliary-cleaning tools.  
2. VACUUM ACCESSORY TOOL HOOK-UP  
To use accessory tool, remove hose from vac shoe  
and attach to accessory tool adaptor.  
3. VACUUM SWITCH  
Turns the vacuum motor On and Off.  
4. PUMP SWITCH  
High pressure no chemical, low pressure with chemical.  
5. CHEMICAL SELECTOR AND METERING VALVE  
Meters the amount of chemical being dispensed and selects  
between chemical A or B and turns chemical off.  
6. CASTER LOCK  
Locks the wheels in place to keep the machine from moving.  
7. VACUUM CIRCUIT BREAKER  
10 Amp. Protects the vacuum motor.  
8. PUMP CIRCUIT BREAKER  
8 Amp. Protects the pump motor.  
9. MAIN SWITCH  
Power on and off switch 230V (ONLY).  
CMPS2 86305210 04/23/08  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATIONS  
FILLING THE MACHINE  
NOTE:Do not put defoamer, solvents  
spotter or prespray chemicals in the  
solution tank.  
3. Attach the adapter cap and intake hose to the  
Compass 2TM Chemical bottle. Refer to the  
Compass 2TM Chemical Label for the desired  
dilution.  
1. Always use gloves and eye protection. Never  
spray solution towards people.  
4. Position the Compass 2TM machine in the door  
way, lock front casters. Start at furthest point in  
the room and work towards the door.  
2. To fill Use fill hose or pour directly into solution  
tank. Use COLD WATER. Add 1 ½ oz of  
CompassRinse TM to each full solution tank.  
CMPS2 86305210 11/21/07  
3-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATIONS  
5. Always Spray chemical using low pressure.  
7. Turn Chemical off. Pressure clean by rinsing  
surfaces at high pressure.  
6. Use brush or grout tool for heavy soiled areas.  
8. Use Squeegee or Gulper tool to remove  
standing water.  
CMPS2 86305210 11/21/07  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATIONS  
UNLOADER  
VALVE  
9. Store and secure hoses and tools neatly.  
11. From the factory your Compass 2 is set to spray  
at 600 psi (high pressure) and 200 psi (low  
pressure w/chemical injection). To lower  
pressure turn the unloader valve knob counter  
clockwise. The valve is accessed from below the  
machine through a hole in the bottom frame.  
Only turn the valve a maximum of three  
revolutions.  
Note: Lowering the pressure in this way will  
reduce both of the high pressure and low  
pressure setting simultaneously.  
10. Drain machine at proper disposal areas. Use  
pressure gun to rinse and clean recovery tank.  
CMPS2 86305210 01/14/08  
3-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATIONS  
Care must be exercised in the use of all  
chemicals. Chemicals are poisonous and  
can pose a health risk. Read and follow  
manfacturers instructions regarding  
dangers and correct usages.  
The internal parts of the pump used in the  
machine are suitable for use with most carpet  
cleaning chemicals. But they are susceptible to  
chemical attack from some cleaning  
substances, such as hydrocarbon solvents and  
chlorinated bleaches. These non-compatible  
materials are not of the type used for carpet  
cleaning.  
CHEMICALS  
Suitable Chemicals Non-Compatible  
Alkalis  
Aldehydes  
Detergents  
Hydroxides  
Soaps  
Aromatics Hydrocarbons  
SP Butyls  
Carbon Tetrachloride  
Clorox*  
Vinegar  
Chlorinated Bleaches  
Chlorinated Hydrocarbons  
Lysol*  
Methyl Ethel Ketone (MEK)  
Perchorethylene (perc)  
Phenolics  
Trichlorethylene  
D-Limonene  
Only use chemicals approved for use with this  
machine. Use of non-compatible chemicals  
may cause machine damage and will not be  
covered under the warranty. Carefully read  
ingredients on manfacturer’s label before using  
any product in this machine.  
Do not let pump run dry.  
Do not let pump run unattended.  
CMPS2 86305210 11/21/07  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
3-10  
CMPS2 86305210 11/21/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
3
1
5
7
6
2
4
1. Float Shut-Off  
2. Strainer  
3. Circuit Breakers  
4. Vacuum Motor  
5. Pump  
6. Adjustable Unloader Valve  
7. Injector Assembly & Coil  
CMPS2 86305210 01/14/08  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
1. FLOAT SHUT-OFF  
3. CIRCUIT BREAKERS  
The float shut-off is located inside the  
recovery tank. The purpose of the float  
shut-off is to notify the user that the  
recovery tank is full. Remove daily and  
clean any debris for maximum airflow.  
Circuit breakers interrupt the flow of power  
in the event of an electrical overload. When  
a circuit breaker is tripped, reset it by  
pressing the exposed button. If a circuit  
breaker continues to trip, the cause of the  
electrical overload should be found and  
corrected.  
2. STRAINER  
8 AMP  
PUMP MOTOR  
10 AMP  
VACUUM MOTOR  
The strainer is located on the left side  
between the front and rear wheels. The  
strainer protects the pump from debris. If  
there is little or no solution flow to the  
ground, check the stainer for debris. Drain  
the solution tank and clean the solution  
strainer. To remove the strainer, turn the  
bottom part of the strainer counterclockwise  
until the bottom is separated. Clean out the  
debris from the wire mesh and reassemble.  
Make sure the o-ring gasket is in place  
when reassembled.  
120V  
7 AMP  
VACUUM MOTOR  
5 AMP  
PUMP MOTOR  
230V  
CMPS2 86305210 04/23/08  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
4. VACUUM MOTOR  
Vacuum Motor Carbon Brushes Replacement (Windsor)  
End Cap  
(Refer to vacuum group in the parts section of  
manual).  
WARNING: The green  
Carbon  
ground wire must be  
Brushes  
attached for safe operation.  
See wiring diagram.  
ONLY QUALIFIED MAINTENANCE PERSONNEL  
ARE TO PERFORM THE FOLLOWING REPAIRS.  
VACUUM MOTOR REPLACEMENT  
1. Turn off all switches and unplug machine.  
2. Remove recovery tank.  
3. Remove the 5 screws holding the vacuum motor  
cover to the solution tank.  
If armature commutator is grooved, extremely pitted or not  
concentric, the motor will need to be replaced or sent to a  
qualified service center.  
4. Locate the vacuum motor wires and disconnect  
at the connector.  
5. Remove the vacuum motor.  
6. Reverse process to install.  
Important:  
These brushes wear quicker as the length shortens due to  
increased heat. Spring inside brush housing will damage  
motor if brushes are allowed to wear away completely.  
3
[9.5mm]  
8
Periodically check the length of the carbon brushes. Replace  
both carbon brushes when either is less than 3/8" (9.5mm)  
long.  
CMPS2 86305210 11/21/07  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
6. REGULATING UNLOADER  
5. PUMP  
ONLY QUALIFIED MAINTENANCE  
PERSONNEL ARE TO PERFORM THE  
FOLLOWING REPAIRS.  
ONLY QUALIFIED MAINTENANCE  
PERSONNEL ARE TO PERFORM THE  
FOLLOWING REPAIRS.  
UNLOADER REPLACEMENT  
1. Turn off all switches and unplug machine.  
2. Tilt machine back so bottom is exposed.  
3. Remove the 6 screws that fasten the frame  
to the solution tank.  
4. Remove the solution hoses from the fittings  
on the pump.  
5. Remove the unloader.  
SOLUTION PUMP REPLACEMENT  
1. Turn off all switches and unplug machine.  
2. Tilt machine back so bottom is exposed.  
3. Remove the 6 screws that fasten the frame  
to the solution tank.  
4. Remove the solution hoses from the fittings  
on the pump.  
5. Reverse process to install.  
6. Reverse process to install.  
PUMP REPLACEMENT KITS  
CAM & BEARING  
86311080 120V  
86305510 230V  
VALVE & O-RING KIT  
(BOTH SIDES)  
86201030  
PRV NO. 250-73B  
PLUNGER & SEALS KIT  
86201080  
PRV NO. 250-25A  
CMPS2 86305210 04/23/08  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
DAILY/REGULAR MAINTENANCE  
PERIODIC MAINTENACE  
Before making any adjustments to the machine,  
disconnect the power cord from the electrical source.  
1. Empty unused cleaning solution from the  
solution tank.  
2. Inspect and clean filter screen in solution tank.  
3. Flush pumping system with 4 to 7 liters of clean  
water.  
Twice a month, flush a white vinegar solution (one  
quart vinegar to two gallons of water) or anti-  
browning solution (mixed as directed) through the  
machine. This will prevent build-up of alkaline  
residue in the system. If spray jets become clogged,  
remove the spray tips, wash them thoroughly, and  
blow dry.  
4. After each use, rinse tank with fresh water.  
Periodically inspect the recovery tank and  
decontaminate if necessary, using a Hospital  
Grade Virucide or a 10-1 bleach to water  
solution. Waste water should be disposed of  
properly.  
5. Remove filter to clean. Filters used for wet pick-  
up including striper must be thoroughly cleaned  
before being allowed to dry.  
NOTE: Do not use pins, wires, etc. to clean nozzles  
as this could destroy the spray pattern.  
Periodically inspect all hoses, electrical cables and  
connections on your machine. Frayed or cracked  
hoses should be repaired or replaced to eliminate  
vacuum or solution pressure loss. The electrical  
cable must be well insulated and cable connector  
screw kept tight. If the cable insulation is broken or  
frayed, repair or replace immediately. Don’t take  
chances with elctrical fire or shock.  
6. Check spray jets for full spray pattern.  
DAILY  
*
WEEKLY  
QUARTERLY  
SERVICE SCHEDULE  
Check machine for cord damage  
Check recovery dome and gasket for damage and  
cleanliness  
Check hoses for wear, blockages, or damage  
Check handles, switches, and knobs for damage  
Check vac motor intake filter and clean  
Run one gallon of water through system  
*
*
*
*
*
*
Clean out recovery tank and check float valve to make  
sure it moves freely  
Clean out solution tank and remove and clean vacuum  
intake screen  
*
*
Clean outside of all tanks and check for damage  
Run vac motor for at least one minute to allow motor to  
dry  
Store with dome off tank to allow the tank to dry  
*
*
Check all bearings for noise  
Check all gaskets for wear and leakage  
*
*
Check vacuum intake screen for damage; replace if  
necessary  
*
Check pump pressure; observe spray pattern and  
check with gauge if necessary  
Check and clean solution screen  
Check cables for fraying  
Check overall performance of machine  
Check vac motor carbon brushes  
*
*
*
*
*
CMPS2 86305210 11/21/07  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
PROBLEM  
CAUSE  
SOLUTION  
Dead electrical circuit  
Faulty power cord  
Check building circuit breaker or fuse box.  
Replace  
Loss of Power  
GFCI breaker is tripped  
Reset breaker on power cord  
Equipment not grounding  
Receptacle not grounded  
Follow grounding instructions exactly  
Contact an electrician to check building’s wiring  
Have a trained service technician check machine’s  
wiring  
Electrical shock  
Internal wiring problem  
Worn motor brushes  
Motor worn out  
Faulty switch  
Replace  
Replace  
Replace  
Vac motor speed varies  
or doesn’t run  
Loose vacuum dome  
Vacuum circuit breaker  
tripped.  
Center and seal dome over tank  
Reset breaker.  
Crack in dome of poor joint Replace or repair using acrylic plastic cement only  
Lint or dirt clogging  
With power off clean screen  
vacuum screen  
Loss of vacuum  
Loose cuffs on vacuum  
Tighten cuffs turning counterclockwise  
hose  
Vac motor seals leaking  
Floor tool vac chamber  
clogged  
Replace  
Wash out with hose. Pick lint out with a wire  
Vac motor, hose, or dome  
gasket  
Replace  
Pump inlet screen plugged Clean inlet screen  
Pump circuit breaker  
Reset breaker.  
tripped.  
Faulty pump switch.  
Faulty pump motor.  
Call for service.  
Call for service.  
Press trigger to open valve on cleaning wand to  
relieve air  
Pump runs no solution  
Pump air locked  
Internal or external  
solution line damaged and Replace  
leaking  
Jet orifice on cleaning  
wand is to large  
Internal pump components  
wearing out  
Total jet opening for 100 psi should be .06 to .08  
Replace, see pump kit components (pg 4-3)  
Pump runs, loss of  
pressure  
Note: Operation of pump using a wand or hand tool with an orifice of less than .06  
will cause pump to cavitate or pulsate and could result in premature wear of pump  
components.  
Check valves in pump  
Take piston from BPR and lubricate with Superlube.  
head for particles or cuts in  
If problem still exists change BPR kit  
seals  
Unit not plugged in  
Loose wiring  
Connect unit to 3 prong grounded outlet  
See dealer  
Pump will not run  
Solution hose fitting hard  
to connect  
Clean with steel wool. Soak in acetic acid (white  
vinegar). Lubricate lightly with silicone base lubricant.  
Corrosion on fittings.  
CMPS2 86305210 11/21/07  
4-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
CMPS2 86305210 11/21/07  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROL PANEL  
2
3
1
11  
12A  
12B  
7A  
7B  
11  
11  
17 16  
5
6A  
6B  
14  
1
4
8
18  
4
13  
9
10  
15  
CMPS2 86305210 04/23/08  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROL PANEL  
SERIAL NO.  
FROM  
REF PART NO. PRV NO. QTY  
DESCRIPTION  
CLAMP, 1/4 ID HOSE  
HOSE, 1/4 ID NYLOCBRAID X 23”  
CAMP CHEM FEED W/DIP TUBE  
VALVE, CHEMICAL METERING  
NUT, 10-32 W/STAR WASHER PLTD  
BREAKER, 10A CIRUIT  
NOTES:  
1
2
86233090  
86282280  
86232110  
86258930  
86005700  
86001940  
86230110  
86215670  
86230200  
86302400  
86197390  
86279560  
86276290  
20016  
39634  
270699  
84187  
57104  
14635  
14312  
140839  
14831  
-
3
2
2
1
2
1
1
1
1
1
1
3
4
1
1
1
2
1
2
1
1
3
4
5
6A  
6B  
7A  
7B  
8
120V  
BREAKER, 7A CIRCUIT  
230V  
120V  
230V  
BREAKER, 8A VDE CIRCUIT  
BREAKER, 5A VDE CIRCUIT  
QD, NIPPLE, FOSTER 25 MPB  
ELBOW, 1/4 NPT 45D STREET  
WASHER, 5/8 ID X 1.70 D 0.05T  
SCR, #10 X 3/4 PPHST HI-LO BLK  
PANEL, SWITCH CONTROL  
PANEL, 3 SWITCH CONTROL  
COUPLER, 1/4 QD  
BOOT, 3/8 CIRCUIT BREAKER  
SWITCH, DPDT3-POSITION ROCKER  
GASKET, SWITCH CARLING  
SWITCH, SPST 2-POSITION ROCKER  
SWITCH, DPST 2 POSITION ROCKER  
9
10  
11  
31021  
87178  
70626  
-
12A 86297370  
12B 86302150  
120V  
230V  
-
13  
14  
15  
16  
17  
18  
86002450  
86002010  
86007200  
86238030  
86007140  
86310280  
22015  
14942  
72162  
36235  
72130  
-
230V ONLY  
CMPS2 86305210 04/23/08  
5-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DECAL  
1
8
2
3
4
7
6
5
CMPS2 86305210 04/23/08  
5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DECAL  
SERIAL NO.  
FROM  
REF  
1
PART NO.  
86299520  
PRV NO.  
-
QTY  
1
DESCRIPTION  
NOTES:  
LABEL, WINDSOR COMPASS,  
CONTROL  
2
3
4
5
6
86302660  
86302650  
86004970  
86305190  
86002870  
-
-
1
1
1
1
1
LABEL, LEFT, COMPASS2  
LABEL, RIGHT, COMPASS2  
LABEL, WINDSOR LOGO DOMED  
INSTRUCTION CARD, CMPS2  
CORD, 1/8” X 12”  
50990  
-
27417  
LABEL, WARNING EXPLOSION  
HAZ’D  
LABEL, COMPASS, 230V, ON/OFF  
7
8
86242230  
86303660  
500009  
-
1
1
CMPS2 86305210 04/23/08  
5-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLUTION TANK  
15  
18  
16  
14  
13  
5
12  
11  
10  
15  
4
5
6
7
9
5
17  
8
3
1
2
19  
20  
21  
CMPS2 86305210 11/21/07  
5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLUTION TANK  
SERIAL NO.  
FROM  
REF  
PART NO.  
PRV NO.  
QTY  
DESCRIPTION  
NOTES:  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
86275800  
86226970  
86300320  
86239680  
86006950  
86224730  
86276650  
86218960  
86301030  
86302130  
86302090  
86002990  
86301990  
86301980  
86276290  
86271680  
86240400  
86260810  
86302590  
86233300  
86197910  
70546  
49-876215  
-
41476  
70532  
73939  
70707  
41575  
-
6
1
1
1
4
1
1
1
1
2
10  
3
1
1
8
1
1
1
1
1
1
SCR, 8 X 3/4 PFHT/S BLK ZINC  
ACCESS COVER CLEAR 3.5” W/RIM  
TANK, SOL CMPS 2  
HOOK, HOSE STORAGE  
SCR, 10-32 X 1/2 PPHMS BLK NP  
SPRING, COMP, 12MM OD X 12.7MM  
SCR, 5/16-18 X 1.5 BSHCS SS  
HOOK, UPPER, CORD  
PLATE, DETENT, CORD HOOK  
CLIP, C 5/8, PLASTIC  
SCR, 8-32 X 7/16 PFHTC “F” BLK  
CLIP, 1 1/2” PLASTIC  
HOSE HOOK, HLDER, TOOL  
HOLDER, TOOL  
SCR, #10 X 3/4 PPHST HI-LO BLK  
NUT, 10-32 HEX NYLOCK BLK  
HOSEBARB, 3/4MPTX1/2 HOSE  
HOSE ASM, 60” FCT ADPTR X CUT  
HOSE, CLEAR, 3/4 ID X 30”  
CLAMP, 1.25” WORM GEAR SS  
HOSEBARB, 1/2MPT X 1/2 POLY DL  
-
-
27744  
-
-
70626  
57236  
40077  
39633  
-
20101  
40022  
CMPS2 86305210 01/14/08  
5-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLUTION-INJECTOR ASSEMBLY  
1
24  
16  
21  
25  
18  
2
15  
12  
13  
14  
26  
1
17  
23  
3
4
21  
5
4
10  
7
1
22  
9
3
6A  
6B  
20  
8
19  
11  
CMPS2 86305210 04/23/08  
5-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLUTION - INJECTOR ASSEMBLY  
SERIAL NO.  
REF PART NO.  
PRV NO.  
QTY  
DESCRIPTION  
NOTES:  
FROM  
1
2
3
4
5
6A  
6B  
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
86302410  
86302570  
86197760  
86247680  
86303760  
86303850  
86308530  
86197300  
86303770  
86305750  
86303750  
86197370  
86006630  
86010650  
86006490  
86305200  
86273980  
86302400  
-
-
3
1
2
2
1
1
1
1
1
1
1
1
2
2
2
1
2
1
4
QD, COUPLER, FOSTER 25FS  
HOSE, PULSE, 3/8F X 3/8F X 45”  
TEE, 1/4 STREET  
NIPPLE, 1/4 HEX  
VALVE, SOLENOID, 1/4F 700PSI  
COIL, 115V, SOLENOID  
COIL, 230V, SOLENOID, CMPS2  
BUSHING, 1/8 FPT X 1/4 MPT HEX  
INJECTOR KIT, DEMA, 200-3C  
NIPPLE, 1/4 X 1/8 REDUCING HEX  
HOSE, ASM, 1/4F X 1/4M, 7”  
ELBOW, 1/4FPT X 1/4FPT  
SCR, 10-24 X 1/2 HHMS SS  
WASHER, #10 X 9/16 OD  
78308  
56015  
-
-
-
14079  
-
-
-
31017  
70171  
87018  
70013  
-
SCR, 8-32 X 3/4 PPHMS  
TERMINAL BLOCK, 115/230V  
SCR, 10-32 X 3/4 PPHMS  
70066  
-
QD, NIPPLE, FOSTER 25MPB  
18  
86005700  
57104  
NUT, 10-32 W/STAR WASHER PLTD  
19  
20  
21  
22  
86233090  
86295830  
86264940  
86197290  
20016  
-
27051  
14076  
1
1
6
1
CLAMP, 1/4 ID HOSE  
HOSE, 1/4ID NYLOBRAID X 41”  
CABLE TIE, 11.38” UL/CSA  
BUSHING, 3/8 MPT X 1/4 FPT HEX  
HOSE, PULSE, 1/4 MPLT X 1/4  
MPLT X 30”  
23  
86302790  
-
1
24  
25  
26  
86188130  
86264940  
86308560  
11-800151  
1
1
1
NIPPLE, 3/8M X 1/4M  
CABLE TIE, 11.38” UL/CSA  
ASM, FILTER MAIN  
27051  
-
230V ONLY  
CMPS2 86305210 02/19/09  
5-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLUTION-PUMP  
20  
18  
1
19  
20  
17  
2
4
16  
14  
3
5A  
5B  
7
8
6
12  
9
12  
10  
11  
13  
12  
9
15  
CMPS2 86305210 04/23/08  
5-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLUTION-PUMP  
SERIAL NO.  
FROM  
REF PART NO.  
PRV NO.  
-
QTY  
1
DESCRIPTION  
NOTES:  
HOSE, PULSE, 1/4MSWL X 3/8NPT X  
30”  
1
86302790  
2
3
4
5A  
5B  
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
86197610  
86233090  
86302780  
86302820  
86308100  
86197540  
40034  
20016  
1
1
1
1
1
1
4
1
2
1
1
3
1
1
5
1
1
1
1
2
HOSEBARB, 3/8MPTX3/8 90D DL  
CLAMP, 1/4 ID HOSE  
-
-
-
HOSE, BRAIDED, 3/8ID X 16” L  
PUMP, PUMPTEC, 700PSI  
PUMP, PUMPTEC, 700PSI, 230V  
HOSEBARB, 3/8MPT X 1/2 DL  
PLUG, 3/8 SOCHD BR  
HOSE, BRAIDED, 1/2 ID X 14” L  
HOSEBARB, 3/8MPTX1/2 90D DL  
STRAINER, 3/8 FPT 80 MESH  
HOSE, BRAIDED, 1/2 ID X 4-3/4” L  
CLAMP, 3/8 HOSE (D-SLOT)  
MOTOR, 700PSI, 115/230 VOLT  
UNLOADER, 800PSI, PUMPTEC  
CABLE TIE, 11.38” UL/CSA  
ELBOW, 3/8FPT X 1/4FPT  
NIPPLE, 1/4 CLOSE  
40013  
86190520 11-800224  
86302770  
86197940  
86305460  
86302760  
86233150  
86302720  
86302730  
86264940  
86197380  
86005590  
86197370  
86302400  
86302410  
-
40027  
-
-
20042  
-
-
27051  
31018  
56014  
31017  
-
ELBOW, 1/4FPT X 1/4FPT  
QD, NIPPLE, FOSTER 25MPB  
QD, COUPLER, FOSTER 25FS  
-
CMPS2 86305210 04/23/08  
5-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLUTION-PUMP  
1
2
7A  
7B  
3
6
5
4
CMPS2 86305210 04/23/08  
5-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SOLUTION-PUMP  
SERIAL NO.  
FROM  
REF  
PART NO.  
PRV NO. QTY  
DESCRIPTION  
NOTES:  
1
2
3
4
5
6
7A  
7B  
86240430  
86233090  
86197910  
86233150  
86010630  
86005810  
86302430  
86307960  
40083  
20016  
40022  
20042  
87013  
57245  
-
1
1
1
1
5
5
1
1
HOSEBARB, 3/8 MPT X 3/8 NYLON  
CLAMP, 1/4 ID HOSE  
HOSEBARB, 1/2MPT X 1/2 POLY DL  
CLAMP, 3/8 HOSE (D-SLOT)  
WASHER, 1/4 ID X 5/8 OD SS  
NUT, 1/4-20 HEX NYLOCK SS  
PUMP ASM, 700 PSI 115V  
COMPLETE  
COMPLETE  
-
PUMP ASM, 700 230V CMPS2  
CMPS2 86305210 04/23/08  
5-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECOVERY TANK  
8
7
5
4
1
3
2
6
10  
12  
11  
1
13  
14  
15  
2
1
16  
9
CMPS2 86305210 11/21/07  
5-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECOVERY TANK  
SERIAL NO.  
NOTES:  
FROM  
REF  
PART NO.  
PRV NO.  
QTY  
DESCRIPTION  
1
2
3
4
5
6
7
86277040  
86010670  
86070510  
86002620  
86275800  
86004000  
86033250  
70781  
87029  
140659  
260-64A  
70546  
11  
11  
1
1
6
SCR, 5/16-18 X 1/2 HHCS SS NP  
WASHER, 5/16 FLAT SS  
BRKT, TANK MOUNT  
ACCESS COVER CLEAR 6” W/RIM  
SCR, 8 X 3/4 PFHT/S BLK ZINC  
GASKET, TANK LID  
PIPE ASM, VACUUM STACK  
FLOAT SCREEN CAGE ASSY  
(SLIP)  
35255  
66402  
1
1
8
86199840  
090-12A  
1
9
86233110  
86300900  
86271850  
86296560  
86240790  
86302360  
86177050  
86302590  
20018  
1
1
1
1
1
1
1
1
CLAMP, 1.0” WORM GEAR  
TANK, REC DK GRY 2  
NUT, 1/2 NPT PLASTIC  
BRACKET, UTILITY MOUNT, 2.0  
HOSEBARB, 1/2 MPT X 3/4 90D  
DRAIN HOSE  
10  
11  
12  
13  
14  
15  
16  
-
57287  
-
82358  
-
03-000176  
-
CLAMP, HOSE #20  
HOSE, CLEAR, 3/4ID X 34”  
CMPS2 86305210 01/14/08  
5-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VACUUM  
13  
15  
14  
1
11  
12  
16A  
16B  
10  
2
3
9
12  
8
12  
7
6
5
4
CMPS2 86305210 04/23/08  
5-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VACUUM  
SERIAL NO.  
FROM  
REF  
PART NO.  
PRV NO. QTY  
DESCRIPTION  
NOTES:  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16A  
-
86237870  
86002380  
86281180  
86240240  
86233260  
86274370  
86005810  
86010640  
86201970  
86003760  
86296140  
86010630  
86007010  
86010670  
86277040  
86303840  
86135320  
86304640  
86135330  
35270  
20046  
39298  
39697  
20092  
70191  
57245  
87016  
065-92  
35166  
-
87013  
70663  
87029  
70781  
-
1
1
1
1
1
1
3
1
3
1
1
9
3
5
5
1
-
GASKET, 5.0 OD X 2.38 ID X .25T  
CLAMP, 2.25” WORM GEAR  
HOSE, 2.0 VAC EXHAUST X 17”  
HOSE, 3.15 ID X 7.0L VENT  
CLAMP, 3.5” WORM GEAR  
SCR, 10-24 X 1/2 HHTC TYPE 23  
NUT, 1/4-20 HEX NYLOCK SS  
WASHER, #10 LOCK EXT STAR SS  
VAC SPACER 2 1/4 (2 STAGE)  
GASKET, VAC MTR  
COVER, VAC MOTOR  
WASHER, 1/4 ID X 5/8 OD SS  
SCR, 1/4-20 X 3 1/4 HHCS PLT  
WASHER, 5/16 FLAT SS  
SCR, 5/16-18 X 1/2 HHCS SS NP  
VAC MTR, 120V 5.7 2 ST TD  
BRUSH SET, 120V VAC WINDSOR  
ASSY, VAC MOTOR, 230V  
115V  
115V  
230V  
230V  
140687  
-
16B  
-
1
-
-
BRUSH SET, 230V VAC MTR  
CMPS2 86305210 04/23/08  
5-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WHEELS & FRAME  
4
1
5
6
7
2
5
9
8
5
3
CMPS2 86305210 03/14/08  
5-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WHEELS & FRAME  
SERIAL NO.  
NOTES:  
FROM  
REF  
PART NO.  
PRV NO. QTY  
DESCRIPTION  
1
2
3
4
5
6
7
8
9
86202280  
86271380  
86270830  
86078800  
86010670  
86276780  
86232620  
86277040  
86296130  
89252  
57196  
57023  
620001  
87029  
70728  
18043  
70781  
-
2
2
8
1
16  
4
2
4
1
WHEEL, 12” BLK CNTRD HUB  
NUT, 1/2 PUH-IN DOME CAP  
NUT, 5/16-18 HEX NYLOCK SS  
PLATE MOUNT CASTER  
WASHER, 5/16 FLAT SS  
SCR, 5/16-18 X 3/4 HHCS SS  
CASTER, 6” DIA X 4.63 SWIVEL  
SCR, 5/16-18X1/2 HHCS SS NP  
FRAME, PUMP/WHEEL MNT  
CMPS2 86305210 03/14/08  
5-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS- STANDARD  
1
2
5
3
4
6
17  
13A  
13B  
7
8
9
16  
10  
11  
7
CMPS2 86305210 11/21/07  
5-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS- STANDARD  
SERIAL NO.  
NOTES:  
FROM  
REF PART NO. PRV NO. QTY  
DESCRIPTION  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13A  
13B  
14  
15  
16  
17  
18  
19  
86257660  
86257650  
86257640  
86257670  
86257680  
86257620  
86301890  
86290390  
86301910  
86301920  
86005580  
86200350  
86240180  
86240250  
86202160  
86234200  
86301880  
86002400  
86241930  
86290410  
02478  
02477  
02475  
02479  
02480  
02473  
-
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
TOOL, HAND SQUEEGEE  
TOOL, SCRUB BRUSH HANDLE  
TOOL, GULPER  
TOOL, TILE BRUSH  
TOOL, ALUMINUM WAND  
TOOL, WHEELED SQUEEGEE  
LANCE, TUBE, 1/4”, 14” LONG  
GUN, PRESSURE WASH PMPTC  
BUSHING, SPRAY GUN  
NOZZLE, ADJUSTABLE, 027 JET  
NIPPLE, 1/4 FPT QD  
HOSE ASM, 1/4HP SLTN 25 FT  
HOSE ASM, 1.5 X 30 FT  
HOSE ASM, 1.5 BLK VAC X 30’  
STRAP, VELCRO  
CORD SET, 14/3 X 50 FT GFCI YLW  
SPRAY GUN  
CLAMP, 2.9” WORM GEAR X .312W  
KIT, SQUEEGEE TOOL BLADES  
NOZZLE REPLACEMENT JET  
-
-
-
56012  
39578  
39637  
39703  
320-05  
23215  
-
20064  
47419  
-
NOT SHOWN  
NOT SHOWN  
NOT SHOWN  
COMPLETE  
-
CMPS2 86305210 11/21/07  
5-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING – SCHEMATIC – 120V  
7
2
GRN/YEL  
WHT  
POWER  
CORD  
POWER  
BLK  
POWER  
CORD  
CONNECTION  
1
5
2
6
3
7
4
8
BLK  
WHT  
BLU  
RED  
ORG  
WHT  
WHT  
9
10  
14  
11  
15  
12  
16  
13  
PUMP  
MOTOR  
VACUUM  
MOTOR  
6
SOLENOID  
GRN/YEL  
GRN/YEL  
1
5 WIRE HARNESS  
GRN/YEL  
ORG  
BLU  
RED  
5 4  
5
BLK  
BLK  
BLK  
4
VACUUM  
CIRCUIT  
BREAKER  
PUMP  
CIRCUIT  
BREAKER  
VACUUM  
SWITCH  
PUMP  
SWITCH  
3
CMPS2 86305210 04/23/08  
5-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING DIAGRAM - 120V  
SERIAL NO.  
NOTES:  
FROM  
REF  
PART NO.  
PRV NO.  
QTY  
DESCRIPTION  
HARNESS, MAIN  
CORD SET, 14/3 X 31  
1
2
86305020  
86305060  
-
-
1
1
3
86308000  
1
WIRE, 6” BLK/14 76050 X 76029  
-
4
5
6
7
88305070  
86268570  
86307990  
86234200  
-
2
2
1
1
WIRE, 2”, BLK/14 76050 X 76029  
WIRE, 3”, BLK/14 76029X 76029  
WIRE, 10”, GRN/14 76010 X 76010  
CORD SET, 14/3X50’ GFCI YLW  
88401  
-
23215  
CMPS2 86305210 04/23/08  
5-22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING – SCHEMATIC – 230V  
GRN/YEL  
BRN  
BLU  
BRN  
BLU  
WHT  
BLK  
EMI  
FILTER  
POWER  
GRB/YEL  
1
WHT/BLK  
POWER  
CORD  
1
5
2
6
3
7
4
8
BLU  
BLK  
BLK  
WHT  
RED  
ORG  
WHT  
WHT  
9
10  
14  
11  
15  
12  
16  
13  
PUMP  
MOTOR  
VACUUM  
MOTOR  
3
SOLENOID  
GRN/YEL  
GRN/YEL  
2
7 WIRE HARNESS  
GRN/YEL  
ORG  
WHT  
BLK  
BLU  
RED  
4
4 5  
BLK  
BLK  
BLK  
WHT/BLK  
5
4
5
VACUUM  
CIRCUIT  
BREAKER  
ON  
OFF  
PUMP  
CIRCUIT  
BREAKER  
VACUUM  
SWITCH  
PUMP  
SWITCH  
CMPS2 86305210 04/23/08  
5-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING DIAGRAM – 230V  
SERIAL NO.  
NOTES:  
FROM  
REF  
PART NO.  
PRV NO.  
QTY  
DESCRIPTION  
1
2
3
4
5
86234330  
86308770  
86307990  
86308750  
86308760  
23711  
1
1
1
3
3
CORD ASM, 1.5MM2X 50’ EURO  
HARNESS, MAIN, 230V  
WIRE, 10” GRN/14 76010 X 79010  
WIRE, 4”, BLK/14 76029 X 76029  
WIRE, 4”, BLK/14 76050 X 76029  
-
-
-
-
SUGGESTED SPARE PARTS  
SERIAL  
NO.  
PART NO.  
PRV NO.  
DESCRIPTION  
NOTES:  
86241930  
86305460  
86135320  
86028720  
86304640  
86135330  
86002010  
86215670  
86001940  
86230200  
86230110  
86241930  
47419  
-
140687  
53266  
-
KIT, SQUEEGEE TOOL BLADES  
STRAINER, 3/8FPT 80 MESH  
BRUSH SET, 120V VAC  
VAC MOTOR ASM, 115V W/ TERM  
ASSY, VAC MOTOR, 230V  
BRUSH SET, 230V VAC MTR  
BOOT, 3/8 CIRCUIT BREAKER  
BREAKER, 8A VDE CIRCUIT  
BREAKER, 10A CIRCUIT  
115V  
115V  
230V  
230V  
-
14942  
140839  
14635  
14831  
14312  
47419  
115V  
115V  
230V  
230V  
BREAKER, 5A VDE CIRCUIT  
BREAKER,7A, CIRCUIT  
KIT, SQUEEGEE TOOL BLADES  
115V &  
230V  
86302720  
-
MOTOR, 700PSI, PUMPTEC  
86302820  
86308100  
86301880  
86301920  
-
-
-
-
PUMP, PUMPTEC, 115/230 VOLT  
PUMP, PUMPTEC, 700PSI, 230V  
SPRAY GUN  
115V  
230V  
NOZZLE, ADJUSTABLE, 027 JET  
CMPS2 86305210 04/23/08  
5-24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VAC HOSE RACK - OPTION  
7
2
4
5
6
1
3
CMPS2 86305210 11/21/07  
6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VAC HOSE RACK - OPTION  
SERIAL NO.  
NOTES:  
FROM  
REF  
PART NO.  
PRV NO.  
QTY  
DESCRIPTION  
HOSE RACK  
SCR, #10 X 3/4 PTHSMS SS  
SCR, 10-32 X 1/2 PPHMS SS NP  
SCR, 1/4-20 X ½ PHTR BLK DL  
CLAMP, 1/4X1/4 BLT VIN DP  
NUT, ¼-20 HEX NYLOCK  
1
2
3
4
5
6
7
86240630  
86276600  
86006590  
86275210  
86270250  
86005680  
86068180  
49499  
70696  
70088  
1
3
2
2
2
2
1
70384  
03-000133  
57047  
140710  
BRACKET, TOP HOSE RACK  
CMPS2 86305210 11/21/07  
6-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS- GROUT CLEANER-OPTION  
CMPS2 86305210 11/21/07  
6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS – GROUT CLEANER-OPTION  
SERIAL NO.  
REF  
PART NO.  
PRV NO.  
QTY  
DESCRIPTION  
NOTES:  
FROM  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
86200820  
86247720  
86194160  
86240190  
86090230  
86241700  
86006590  
86088740  
86308040  
86270990  
86308780  
86276290  
86000480  
270-11A  
56032  
11-800133  
39639  
87015  
44079  
70088  
02476  
-
57090  
-
70626  
47431  
1
1
1
2
4
2
4
1
2
4
2
4
NIPPLE, 1/8 FPT QD MALE BRASS  
NIPPLE, 1/8 CLOSE  
TEE, 1/8 BR  
HOSE, 1/8 MPT X 1/4 FPT X 12L  
WASHER, 9/16 ID X 1.06 OD SS  
JET, 1/4 MEG 15015  
SCR, 10-32 X 1/2 PPHMS SS NP  
TOOL, GROUT CLEANER  
BRUSH, FLOOR TOOL  
NUT, 10-32 HEX NYLOCK SS  
BRKT, BRUSH MOUNT  
SCR, #10 X 3/4 PPHST HI-LO BLK  
REF KIT, GROUT CLEANER  
CMPS2 86305210 03/14/08  
6-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS- HIGH PRESSURE WAND-OPTION  
CMPS2 86305210 01/14/08  
6-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS – HIGH PRESSURE WAND-OPTION  
SERIAL NO.  
REF  
PART NO.  
PRV NO.  
QTY  
DESCRIPTION  
NIPPLE, 1/4 FPT QD  
HOSE, 1/8 MPT X 1/4 MPT X 7 L  
SCR, 10-32 X 1.25 PPHMS SS  
VALVE, 500 PSI W/ CLAMP  
HOSE, 1/8 MPT X 1/8 MPT X 38L  
NIPPLE, 1/8 FPT QD FEM BRASS  
TOOL, ALUMINUM WAND  
NOTES:  
FROM  
1
2
3
4
5
6
7
8
9
86005580  
86240210  
86274410  
86258950  
86240200  
86200810  
86257680  
86270990  
86041300  
86135760  
56012  
39641  
70195  
84189  
39640  
270-11  
02480  
57090  
47432  
38109  
1
1
1
1
1
1
1
1
NUT, 10-32 HEX NYLOCK SS  
REF KIT, HIGH PRESSURE WAND  
HANDLE GRIP ASSEMBLY 1.5”T  
COMPLETE  
10  
1
CMPS2 86305210 01/14/08  
6-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS- CARPET TOOL- OPTION  
7
1
2
3
4
5
6
CMPS2 86305210 11/21/07  
6-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS – CARPET TOOL- OPTION  
SERIAL NO.  
REF  
PART NO.  
PRV NO. QTY  
DESCRIPTION  
NOTES:  
FROM  
1
2
3
86200820  
86240220  
86296220  
270-11A  
39642  
-
1
1
1
NIPPLE, 1/8 FPT QD MALE BRASS  
HOSE, 1/8 MPT X 1/8 MPT  
ELBOW, 1/8 FPT  
WASHER, .45ID X .87X .20THK  
NYL  
WASHER, .40ID X .87OD X  
.060THK SST  
4
5
86305440  
86305450  
-
-
1
1
6
7
86241710  
86284550  
44080  
02484  
1
-
JET, 1/4 H-VV 11003  
TOOL, CARPET CLEANER  
COMPLETE  
CMPS2 86305210 01/14/08  
6-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STORAGE BAG-OPTION  
CMPS2 86305210 11/21/07  
6-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STORAGE BAG-OPTION  
SERIAL NO.  
NOTES:  
FROM  
REF  
1
PART NO.  
86283390  
PRV NO.  
47423  
QTY  
1
DESCRIPTION  
KIT, STORAGE BAG  
CMPS2 86305210 11/21/07  
6-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHEMICAL LOCK-OPTION  
CMPS2 86305210 11/21/07  
6-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHEMICAL LOCK-OPTION  
SERIAL NO.  
NOTES:  
FROM  
REF  
1
PART NO.  
86070520  
PRV NO. QTY  
140660  
DESCRIPTION  
1
BRKT, CHEMICAL LOCK  
CMPS2 86305210 11/21/07  
6-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERIAL NUMBERS  
REF.  
NO.  
1
MODEL: SERIAL #:  
---  
CMPS 86305210 04/23/08  
6-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weed Eater Trimmer 530164314 User Manual
Whirlpool Dishwasher DU1055XTSB1 User Manual
Whirlpool Freezer EV150L User Manual
Whirlpool Washer AL5143V User Manual
White Rodgers Water Dispenser 8J48A User Manual
Winegard TV Antenna FL 5000 User Manual
Xantech Stereo Amplifier XSS24100W User Manual
Xerox Copier N4525 User Manual
Zanussi Microwave Oven AG125 User Manual
Zanussi Range ZCM 7902 User Manual