| EXTREME SERIES   OWNER’S MANUAL   Platinum 4000   Platinum 8000   8000ti   The Coolest Thing In Wine Storage   Download from Www.Somanuals.com. All Manuals Search And Download.   TABLE OF CONTENTS   WhisperKOOL Extreme Series Quick Reference Guide . . . . . . . .4 Controller Quick Reference Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Receiving & Inspecting The Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Preparing the Wine Cellar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13   Through-The-Wall Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14   Installation Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17   Ducted Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18   Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22   Liquid Measuring Thermostat System. . . . . . . . . . . . . . . . . . . . . . . 24   Variable Speed Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25   System Operation: Standard and Remote . . . . . . . . . . . . . . . . . . . 26   Control Panel Features and Operation . . . . . . . . . . . . . . . . . . . . . . 27   Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30   Troubleshooting Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31   Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33   Installation Terms and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 34   Page 3   Download from Www.Somanuals.com. All Manuals Search And Download.   WHISPERKOOL Series QUICK REFERENCE GUIDE   Front / Side View   Front Grille   Probe Input   TM   HIGH   MED   L O W Controller   Control Panel   Speed Control (only 8000ti models)   Rear View   Posterior Grille   Rear Power Option   Drain Port   Page 4   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   CONTROLLER QUICK REFERENCE GUIDE   Defrost   Compressor   Evaporator Fan   Cellar “Pre-Chill” Buꢀon 3-5   Hi Boꢀle Temp History & Scroll   Energy Reducꢁon   Buꢀon   1 Buꢀon   1 Energy Reducꢁon   Low Boꢀle Temp History & Scroll   Set Buꢀon   •View Set Point   Buꢀon   1 1 •Change Set Point 3-5   •SET + Down = CPSM 3-5   •Reset Hi & Lo Buꢀon 3-5   Control “ON/OFF” Buꢀon   Turns the Cooling Unit   • “ON/OFF”   1 Condenser Fan   ALARM   Pre-Chill Display   Note: The 1 or 3-5 qualifies the amount of time in seconds that the button must be pushed to activate the feature.   FAN SPEED REFERENCE   (Extreme 8000ti only)   Your fan speed will depend on thermal load on the wine cellar, and resulting cooling that is required to cool and   maintain your wine cellar at the desired temperature.   Speed   Low   CFM   274   318   333   DBA*   Cellar Capacity**   1500 cu. ft.   Evaporator/Condenser   57/57   59/59   60/61   Medium   High   1750 cu. ft.   2000 cu. ft.   * To get a feeling for decibels, a food blender at 3 ft. is 90 dBA, garbage disposal at 3 ft. 85 dBA, vacuum cleaner at   10 ft. is 75 dBA, normal speech at 3 ft. 79 dBA, dishwasher in the next room 55 dBA, Quiet night 35 dBA.   **Based on proper cellar construction and accounting for any windows or non insulated surfaces.   Please refer to the Preparing the Wine Cellar section on page 8 for more information.   Page 5   Download from Www.Somanuals.com. All Manuals Search And Download.   INTRODUCTION   Customer Service   Thank you for purchasing a WhisperKOOL Extreme Series cooling unit. We strive to provide the highest quality prod-   ucts and the best possible customer service. If you have any questions about your WhisperKOOL unit, please call us   at 1(800) 343-9463.   Using the Manual   This User’s Manual is intended to assist in the proper installation and maintenance of the WhisperKOOL Extreme   cooling system. In order to ensure the longevity of your cooling unit, the equipment should be installed properly and   have a proper care and maintenance schedule. Please read and review this manual carefully and keep it for future   reference.   What Is the WhisperKOOL Extreme Series Cooling System?   The WhisperKOOL Extreme Series system is a specialized refrigeration unit designed for one purpose only: to main-   tain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines. It is a   self-contained cooling unit designed to be used as a forced-air through-the-wall unit or as a remote mount unit with   external duct work connections.   How Does the WhisperKOOL Extreme Series Work?   The WhisperKOOL Extreme Series cooling system is especially designed for the use and application to maintain opti-   mal conditions for wine storage and aging. The system is fully self-contained and can be installed as a “Thru-The-Wall’   application, or the unit is capable of an even more flexible “Ducted”application, which allows the unit to be placed in   an indoor remote site, resulting in a quiet airflow. Both models offer an alarm interface with your current alarm sys-   tem, or an optional auto-dialer. You can also choose to have direct access to your control system via the Internet us-   ing a cell phone or computer, which will allow you to monitor the system, access data history, edit control parameters,   and receive email/cell phone alarm notifications. The standard “Through-the-Wall”and ducted units are temperature   controlled via a bottle probe, and the ducted system comes standard with a remote key board that can be located up   to 300 ft from the cooling system (Note: Remote Unit comes standard with a 50 ft cord and remote keypad, additional   lengths are optional).   Temperature Setting   The WhisperKOOL Extreme unit can be set at any temperature within the acceptable wine-aging range of 50°F to   67°F. It is designed to cool 55°F cooler than the ambient temperature of the space to which it is exhausting.   Model   4000   8000   8000ti   Cellar Size   Dimensions   Weight   1000 cu. ft.   2000 cu. ft.   up to 2000 cu. ft.   14.25”W x 22.5”H x 27.5”D   110 lb.   14.25”W x 15.75”H x 25.5”D 14.25”W x 22.5”H x 27.5”D   85 lb.   110 lb.   36/10   66   AMPS (starting/running) 32/9   00   dBA   67   57 low 59 med. 60 high   Installation   Thermostat   Through-the-Wall, partially ducted, fully ducted   Digital Control Display   55°F temperature differential   (maintains proper cellar temperature when exhaust environment does not exceed 110°F)   Temp. Delta   Can be done if the outside temperature does not exceed 110°F, the external grille   cover is highly recommended.   Outside Venting   Ducting Options   Warranty   Unit can be fully ducted.   2 year parts and labor / 5 year compressor   Page 6   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   RECEIVING & INSPECTING THE UNIT   Customer Warranty Registration   PLEASE COMPLETE AND RETURN THE WARRANTY CARD UPON RECEIPT OF THE UNIT.   By completing the Product Registration Card, you will be confirmed in our customer database ensuring that   your information is on file to help you obtain efficient warranty service.   Please refer to pages 34 - 36 for complete terms and conditions, warranty guidelines, and policy for your Whis-   perKOOL Extreme Series cooling unit.   Receiving and Inspecting the Unit   Note: WhisperKOOL Extreme units are manufactured in the USA and tested prior to shipment.   • Lift only at the designated hand hold locations on the shipping container or fully support the unit from   underneath. A shipment may include one or more boxes containing accessories.   • • • Before opening the container, inspect the packaging for any obvious signs of damage or mishandling.   Write any discrepancy or visual damage on the Bill of Lading before signing.   Place the box containing the WhisperKOOL unit on a tabletop to prepare it for installation and testing.   Review the Packing Slip to Verify Contents   • • Check the model number to ensure it is correct.   Check that all factory options ordered are listed.   If any items listed on the packing slip do not match your order information, contact WhisperKOOL Customer   Service immediately.   Check the Accessory Kits for the following contents:   Kit One:   • WhisperKOOL Extreme Series User’s Manual   Registration / Warranty Card   • Kit Two:   • • • • • • • Power Cord   Standard Screws (9)   Self-Tapping Screws (9)   Drain Line tube (1), Connection “T”(1), and Clamp (1)   Mounting Flange Pieces (4)   Bottle Temperature Probe (Standard Unit)   Insulation Foam (4 strips)   Please leave the WhisperKOOL unit in its original box until you are ready for installation. This will allow you to   move the product safely without damaging it. When you are ready to remove the product from the box, refer to   page 13 for installation instructions.   Note: Save your box and all packaging materials. They provide the only safe means of transporting/shipping   the unit.   Page 7   Download from Www.Somanuals.com. All Manuals Search And Download.   PREPARING THE WINE CELLAR   The performance and life of your WhisperKOOL unit are contingent upon the steps you take in preparing the   wine cellar.   Note: Improperly preparing your enclosure or incorrectly installing your WhisperKOOL unit may cause unit fail-   ure, leaking of condensation, and other negative side effects.   IT IS HIGHLY RECOMMENDED THAT YOU OBTAIN THE ASSISTANCE OF A   WINE STORAGE PROFESSIONAL.   Wine storage professionals work with licensed contractors, refrigeration technicians, and racking companies to   build well-insulated, beautiful, and protective wine cellars. WhisperKOOL has put together some useful tips to   assist in the installation process. Our recommendations are meant to act as a guide in the process of building a   proper enclosure. Your intended location may have specific needs that we do not address.   Wall & Ceiling Framing   Build wine cellar walls using standard 2x4 or 2x6 construction methods and ceiling joists following the guide-   lines of local and state codes in your area. As a general rule, the thicker the walls and the higher the insulation   factor in your cellar, the better it will be at maintaining a consistent temperature.   Insulation   Insulation is REQUIRED with the use of the WhisperKOOL product. Standard fiberglass or rigid foam insulation   is normally used in cellar construction or, in some cases, “blown-in”insulation is used. It is very important that   all walls and ceilings are insulated to keep the cellar temperature as consistent as possible during the summer   and winter months. The R-factor, or quality of insulation, is determined by the rate at which heat passes through   the insulation. The higher the R-factor, the more resistant the insulation is to conducting heat. Using higher   R-values in insulation will lower your operating costs and unit run time. (R-13 minimum, R19 recommended, R30   for ceiling and exterior walls)   Vapor Barrier   Vapor Barrier is REQUIRED to prevent the intrusion of water vapor so that the cellar can be kept at the correct   temperature and humidity. 6 mm plastic sheeting (recommended) should be applied to the warm side of the   cellar walls. The vapor barrier must also be applied to the outside walls and ceiling. If it is impossible to reach   the outside, then the plastic must be applied from within the cellar. The most common method is to wrap the   entire interior, leaving the plastic loose in the stud cavity so the insulation can be placed between each stud. All   of the walls and ceiling must be wrapped in plastic for a complete vapor barrier.   In areas of high humidity, such as Southern and Gulf States, the vapor barrier will prevent infiltration of warm   moist air. The moist air can cause mold to form, and standing water in drain pans promote microbial and fungal   growth that cause unpleasant odors and indoor air quality problems. If mold is found, remove it immediately   and sanitize that portion of the unit.   Page 8   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   Mounting the Unit   Unobstructed Airflow   The unit should be mounted within 18“ of the   top of the room in order to achieve sufficient   cooling. As the room cools down, the warm   air will rise to the ceiling. Mounting the Whis-   perKOOL high in the room will create a consis-   tently cool environment by capturing the warm   air and replacing it with cool air. Mounting the   unit low in the room will result in a temperature   variation in the room due to the unit’s inability   to draw warm air from the ceiling of the cellar to   the unit itself.   Unobstructed airflow to and from the   unit is a critical factor in the unit’s overall   performance. Make sure there is a 3 ft.   horizontal clearance in the front of the   unit. This will assure that the unit can   move the air around in an efficient man-   ner. Avoid any attempt to camouflage   the unit by installing racking in front of   the unit. This will restrict the airflow and   lower the performance of the unit.   Exhaust Room   Exhaust   Front of Unit   Intake   Wine Cellar   Door and Door Seal   An exterior grade (1 3/4”) door must be installed as a   cellar door. It is very important that weather stripping   is attached to all 4 sides of the door jam. A bottom   “sweep”or threshold is also required. The door must   have a very good seal to keep the cool cellar air from   escaping out of the cellar. One of the most common   problems with cooling units running continually is the   door not sealing properly. In cases where glass doors   are used and the room size is close to the recom-   mended unit size, the next larger size WhisperKOOL   should be used. This will compensate for the insula-   tion loss due to the inefficient door.   TM   Page 9   Download from Www.Somanuals.com. All Manuals Search And Download.   Ventilation   The necessity of dissipating heat away from the unit is critical to the unit’s performance and cannot be over-   stated. As the unit operates and cools, a greater amount of heat is generated on the exhaust side of the unit.   Adequate ventilation is required in order to dissipate heat away from the unit. If ventilation is inadequate, the   exhaust will heat up and adversely affect the unit’s ability to cool. In some cases, it may be advisable to install a   vent fan to dissipate heat within the exhaust area on the backside of the unit. However, you must have a fresh   air inlet as well. If your unit requires ducting, please contact WhisperKOOL Customer Service to obtain a spe-   cially designed ducting accessory kit for the unit. Using any other ducting system will void the warranty.   Ambient Temperature Factor   The cooling system has the ability to cool a maximum of 55°F below the ambient temperature of the room it   is exhausting to. Therefore, you want to exhaust the unit in a room which will not exceed 105°F. Otherwise the   unit will not have the capacity to keep the wine at a desirable 55°F.   Unobstructed Airflow   Unobstructed airflow to and from the unit is a critical factor in the unit’s overall performance. Make sure there is   a minimum 3 ft. horizontal clearance from the rear of the unit as well as a minimum 3 ft. clearance in front of the   evaporator fans. This will assure that the unit can move the air around in an efficient manner.   Back - Exhaust Room   Front - Wine Cellar   Exhaust Fan   WhisperKOOL   (side view)   110ºF   55ºF   Air Intake   Cellar Wall   How to Build a Wine Cellar Instructional Video   through the steps of constructing a properly built wine cellar and the installation of our WhisperKOOL product line.   Page 10   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   Sizing the Unit to the Room   Model   Cellar Volume   AMP’s   (starting)   32   AMP’s   (running)   9 Product Dimensions   (W x H x D)   (cubic feet)   1000   4000   14.25”x 15.75”x 25.5”   8000   2000   36   36   10   10   14.25”x 22”x 27”   14.25”x 22”x 27”   high   8000ti   2000   1750   1500   med   low   8000ti   8000ti   36   36   10   10   14.25”x 22”x 27”   14.25”x 22”x 27”   Cutting the Hole for the WhisperKOOL Unit   Tools Needed   Level   Hammer   Screwdriver   Saw   Locate the center of the wall upon which the unit will be installed. Using a stud finder, locate the studs on either   side of the center point, and mark them with vertical lines.   Using a level and a pencil, mark a horizontal line on   the wall between the two studs, approximately 1.25”   (or as close as possible if more than 1.25”) from the   ceiling.   Using a ruler or measuring tape, measure 16”down,   and mark another horizontal line parallel to the first   one.   Mark the horizontal lines with a level   Using a saw, cut along the uppermost horizontal line   until your saw reaches the stud. Turn the saw around,   inserting it into the cut you have just made, and cut   toward the opposite stud so that you have a clean hori-   zontal cut between the two studs. Be careful not to cut   into the studs themselves.   Now make the second horizontal cut from stud to stud   on the line 16”below the first cut.   Page 11   Download from Www.Somanuals.com. All Manuals Search And Download.   Once the horizontal lines have been cut, make vertical cuts using the inside edge of the studs as a guide. Once   you have made both vertical cuts, you should have a rectangular hole in the sheetrock. Now you have to make   the same hole on the other side of the wall. Since you already have one hole, this is an easy process. Using a nail,   mark all four corners of the first hole by making nail holes through the sheetrock. Then on the other side of the   wall, connect the holes with a pencil mark and cut.   Sheetrock alone cannot support the weight of a 65 lb.   (or more) cooling system. Therefore, it is necessary to   frame the hole that you have just cut with upper and   lower supports.   Using two 2x4’s at 14.5”in length and eight 6d nails,   secure the upper and lower supports to the right and   left studs, just inside the sheetrock. Make sure that the   internal height remains at 16”so that the WhisperKOOL   system will fit snugly through the framed cut-out.   Frame the hole with two-by-four supports   Page 12   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   INSTALLATION   Electrical Needs   The WhisperKOOL Extreme System requires a dedicated 115-volt 15-amp circuit. The unit draws a large amount   of amps at initial start up. By designating a dedicated circuit breaker, you will guarantee the unit has enough   power to run effectively. Contact an electrician for assistance with the installation of this dedicated electrical   circuit:   1. Match the electrical outlet to the plug provided on the WhisperKOOL unit.   2. Provide a dedicated circuit and wiring for the unit.   3. Provide a weatherproof plug for units mounted outside.   4. Mount outside units at a height of 18”and provide overhead protection.   Electrical Outlet   The unit is equipped with two electrical outlets: one for the interior or cellar side and one for the exterior or   outside of the cellar. There is a toggle switch located on the right side of the unit that indicates front (cellar side)   and rear (exterior side). When placed in either position, power will come from that outlet only.   Plug your WhisperKOOL unit into a surge protector or power conditioner. As with any sensitive electrical equip-   ment, the WhisperKOOL electrical equipment may be damaged by power surges and spikes. Power surges and   spikes are not covered in the WhisperKOOL Extreme warranty.   WE RECOMMEND THAT YOU DO NOT USE A GROUND FAULT INTERRUPTER (GFI) WITH THIS PRODUCT.   In case the unit should lose power, press the reset button and attempt to turn the unit back on. Check the home/   main circuit breaker. If the unit does not respond properly, refer to the Troubleshooting section on page 31.   Manual   Reset   FRONT   Communication   REAR   Access Port   Front   Power   Plug   Front / Rear   Power Switch   Test the Unit Prior to Installation   To prepare it for testing before installation in wall:   • • • • • • • Remove unit from box   Place unit on tabletop   Plug in unit to electrical outlet   Plug in bottle sensor   Turn on to test (Should be 12°F across coils)   Turn off after test   Remove bottle sensor   Page 13   Download from Www.Somanuals.com. All Manuals Search And Download.   THROUGH-THE-WALL INSTALLATION (without ductwork)   Mounting Flange Pieces   There are four individual pieces located in Kit 2 of your enclosed accessory kits. These flange pieces are de-   signed to be used on the backside of the Extreme Series to mount to the exterior wall. There are three punch-   outs located on the exterior of the housing. The punch-outs are designed for specific through-the-wall installa-   tion mounts. Please refer to the illustration for location of the punch-outs.   #1. Retrofit your current WhisperKOOL   cooling unit   #2. Middle wall installation   #3. Flush mount to exterior wall   Back of unit   Applying Insulation Tape   Locate the four precut pieces of   black foam tape included with the   system. There should be two larger   pieces and two smaller pieces. Once   you have attached the flange pieces   to the unit, peel back the white-   paper adhesive covering and place   on the corresponding size of flange.   The large pieces are applied to the   top and bottom of the unit and the   smaller pieces to the right and left   side flanges. This foam creates a   tight seal between the flange and   the wall.   Front of unit   Page 14   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   Placement of Unit   Slide the unit from either the inside or outside wall into your wine cellar with the outer flange flush to the wall.   You will need to reverse the mounting flange depending on inside or outside use. Secure the flange to the wall   through the pre-drilled holes. The screws should penetrate the studs as well as the upper and lower supports   to provide adequate support for the WhisperKOOL system (see illustration). Seal all cracks and gaps around the   WhisperKOOL Extreme unit with an air-tight sealant or caulking to prevent air leakage.   Note: If you use decorative molding, it should be attached to the walls and never to the cooling unit itself.   2x4 Upper Support   Wall Stud   Mounting Flange   Back of unit   2x4 Lower Support   Drain Port   Electrical Outlet   Location of Supply and Return Grilles   Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes air circulation in   the room. Avoid short circulation of the air.   Do not:   • • • Install through-the-wall return air grilles at floor level, as they will collect dust from the floor.   Mount the unit lower than 18”from the top of the room.   Locate the supply or return air grille where it is blocked by bottles, boxes or cases.   Page 15   Download from Www.Somanuals.com. All Manuals Search And Download.   Condensation Drain Line Tube   The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge   location. It is important that the drain line tube is properly connected and used to prevent leakage and other   problems associated with excess condensation.   Failure to use the condensation drain line tube will void the warranty on the unit.   Drain Line   Page 16   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   INSTALLATION OPTIONS   Exterior Grille Installation   The exterior grille is required on all installations where the condenser side of the unit is exposed to the outside   of the dwelling (i.e. rain and weather).   The condenser grille must be removed. Locate the screws at the bottom of the grille and remove. Using me-   dium force, push the grille upward and lift the grille away from the unit. Replace the bottom screws and tighten   the upper screws.   Now determine at what depth the unit will be installed:   • For a non-flush installation (i.e. holes location #1 WhisperKOOL retrofit or #2 Middle Wall), place the grille   on the condenser end and line up the holes on the grille with the holes on unit location #3. Use the 10   screws provided to fasten the grille to the unit.   • For a flush installation, place the grille on the condenser side and then place the mounting bracket over   the grille sides, “stacking”them. Align the holes and fasten with the 10 screws provided.   Non-Flush Installation   Flush Installation   Page 17   Download from Www.Somanuals.com. All Manuals Search And Download.   DUCTED INSTALLATION   Use duct work to connect the unit to the supply and return outlets in the wine cellar. Use only insulated duct   work to minimize cooling losses, prevent sweating, and reduce noise.   Use duct work on the condenser section to redirect or absorb sound, bring in outside air to the unit inlet, and/or   exhaust the hot air.   Note: Do not exceed a total of 25’for each length of duct work run and a total of 50’combined for both the   supply and return lengths.   Avoid crimping the flexible ducts. This chokes down the inside area and reduces the airflow causing the unit to   operate erratically.   Be sure all ducts and surfaces in contact with the airflow are insulated and have a vapor barrier on the outside.   Un-insulated ducts and surfaces cause bare, exposed metal surfaces to sweat, further   degrading the insulation and equipment cooling capacity.   General Duct Recommendations   • • • • • • • • • Provide support for the flexible duct to prevent sags and bends.   Stretch out the duct to make a smoother interior, which reduces air resistance.   For 90° bends, use a 90° adjustable elbow (Ell).   Do not squeeze or reduce the inside diameter of the ducts, which reduces airflow.   Use short and straight duct work where possible.   Remove the grilles and panels from the openings to connect the duct work.   Check that all fan blades move freely.   Keep air paths free of loose foreign objects and debris.   Connect the round flexible ducts to the WhisperKOOL unit using the duct collars provided with the duct   accessory kit.   • Pull the outer plastic wrapping and insulation away from the end of the duct to expose the reinforced   inside duct liner.   • • • Fasten the duct collar using tie straps or clamps around the inside liner.   Secure the duct collar to the unit using the screws provided. Take care to not damage or bend the gasket.   Use approved duct tape to seal all joints.   Do not clamp around the outside insulation, as it will compress and loosen over time.   Cold Air to/from Wine Cellar   • • Remove the supply air grille to install duct work between WhisperKOOL unit and the cellar.   Connect the supply air duct work from the cellar to the supply air outlet adapter flange at the   WhisperKOOL unit.   • Connect the return air duct work from the cellar to the return air inlet adapter flange at the   WhisperKOOL unit.   Warm Air to/from Wine Cellar   • • Connect duct work on the condenser to direct heat and air noise away from occupants.   Connect duct work to another space within the basement or out of the building if exhausted heat is   undesirable.   Page 18   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   DUCTED INSTALLATION cont.   STEP 1:   Remove the grill from the unit by   unscrewing the screws that hold it in place.   STEP 2:   Move the duct plenum into place   STEP 3:   Screw the plenum into place using the   same screws that held the grill in place.   HIGH   MED   L O W Page 19   Download from Www.Somanuals.com. All Manuals Search And Download.   STANDARD DUCTED INSTALLATION   Dual Outlet Duct   Cold Air Supply-Cellar   Heat Exhaust   Return Air-Cellar Side   Condenser Intake   Attic Mounted System   Condenser Exhaust   Cold Air   Return Air   Condenser   Intake   Adjacent Room   Wine Cellar   Fresh Air   Intake   Page 20   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   STANDARD DUCTED INSTALLATION   Dual Outlet Duct   Adjacent Room   Wine Cellar   Return Air-Cellar Side   Outside through the Wall   Adjacent Room   Wine Cellar   Condenser   Intake   Return Air-Cellar Side   Page 21   Download from Www.Somanuals.com. All Manuals Search And Download.   REMOTE CONTROLLER: INSTALLATION AND CONFIGURATION   The WhisperKOOL Extreme Series can be configured with a remote controller system. If you have a unit with a   remote controller, please review this section.   The controller can be installed up to 50 feet away from the cooling unit, or up to 300 feet away with the extend-   ed connection wire.   To install the remote controller, remove the mounting bracket and secure the bracket to the wall in the desired   location. Reattach the controller to the bracket.   Mounting Bracket   Attach the connection wire as shown below, with the red wire in the upper connection slot and the black wire in   the lower slot.   Red Wire   Black Wire   Page 22   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   Connection wire in Side Mount configuration   Connection wire in Rear Mount configuration   Below is an illustration of one possible way to configure the remote controller in a wine cellar.   Cooling Unit   Bottle Probe   Remote   Controller   Page 23   Download from Www.Somanuals.com. All Manuals Search And Download.   LIQUID MEASURING THERMOSTAT SYSTEM   The WhisperKOOL Series cooling units come equipped with a liquid temperature measuring thermostat system.   This system incorporates the following advantages:   1. Self-Calibrating Probe: The probe contains a sensor chip, which actually communicates back and forth   to the thermostat. This results in a consistent temperature setting and accuracy. Do not remove the tip   from the probe!   2. Heavy-duty Circuitry: The circuitry within this new unit has been upgraded to resist power surges,   which play havoc on electrical components. This improvement will ensure years of trouble-free use.   However, for the highest reliability, we recommend that the customer install a surge protector for the   unit itself.   Measuring liquid temperature has a few unique advantages:   1. Wine temperature is kept in a very precise controlled environment. This assures a consistent tempera-   ture.   2. By measuring the liquid temperature rather than air, the unit will operate 75- 80% of the time.   To Use the thermostat:   1. Locate an empty wine bottle.   2. Fill 3/4 full with room temperature tap water.   3. Place bottle probe securely into bottle.   4. Place bottle with probe level and to the side   of the unit in your wine cellar. Avoid pulling   too much on the probe cord. It may become   disconnected resulting in non-operation of the   unit.   Note: The thermostat can be set between 50°F   and 76°F.   Remember: The WhisperKOOL System is based on   the temperature of the water.   Page 24   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   VARIABLE SPEED CONTROL   (only on the 8000ti)   Designed for wine cellars from 1500 to 2000 cubic feet, the Extreme 8000ti features variable-speed fans with a   “high”setting for maximum performance in high-temperature (+110°F) environments and a “low”setting for   super-quiet operation.   Fan Speed Selector Switch (Low/Med/High): The cooling unit fans operate on 3 speed settings: Low, Medium,   and High. For optimum sound and energy efficiency, select the lowest fan speed that will maintain the desired   cellar temperature. High speed is recommended for initial cellar cool down, extreme temperature conditions   and ducted installations.   SET   Page 25   Download from Www.Somanuals.com. All Manuals Search And Download.   SYSTEM OPERATION: STANDARD & REMOTE   Initial Start-Up   Low Ambient Conditions   When power is applied to the unit, the control will   briefly display all symbols, and the Compressor sym-   bol will be displayed (if unit is calling for cooling).   If the unit is installed in a Through-The-Wall applica-   tion (which will allow the condenser to be exposed to   low ambient temperatures), the condenser fan may   There may be a brief delay prior to the evaporator and cycle on and off. The purpose of the fan cycling is to   condenser fans turning on, as the fans will not turn on maintain the system high side pressure, which will   until the sensors reach their perspective start tem-   peratures (below 70°F for the evaporator and above   80°F for the condenser). When the condenser fan is   ensure an adequate refrigeration process. The fan cy-   cling process is accomplished by way of a temperature   probe attached to the condenser coil.   activated the “AUX”symbol will turn off, and when the Note: Remote control systems do not use condenser   evaporator fan is activated the “FAN”symbol will turn   on. The temperature control feature for the evapora-   tor fan is a feature applicable to Whisperkool Advance   Product Safety Technology (APST), which ensures   that in the possible event of a cooling deficiency, the   heat from the indoor fan will not raise the heat of the   wine cellar, which could otherwise have an adverse   effect on the wine aging process. After the indoor   coil reaches a temperature below 70°F, the indoor fan   symbol will be displayed and the fan will turn on.   Note: For remote system condenser fan cycles with   the compressor, the “Aux”symbol does not apply.   fan cycling.   Bottle Probe Failure Protection   In the event that a bottle probe should fail, the APST   (Advance Product Safety Technology) will automati-   cally transition the Refrigeration Compressor cycles   to a pre-determined time series (based on detailed   laboratory testing), which will ensure that the product   is kept within the safe range.   Remote Control Panel (optional)   The control panel can be installed or mounted sepa-   rately from the cooling unit itself (remotely), using the   supplied cable. This option provides unique flexibility   for installing the Extreme Series cooling unit in your   wine cellar. The remote option must be specified when   the unit is ordered.   Normal System Cycle   After the bottle probe has reached the set point (all   units are shipped with the set point of 55°F and a dif-   ferential of 1°F), the compressor and the condenser   fan will turn off, but the indoor fan will continue to   run for about 5 minutes, which is a feature of the   WhisperKOOL Humidity Management (WHM) system.   The WHM is an adjustable feature which allows the   customer the convenience of managing the humid-   ity enhancement of their wine cellar. The WHM is one   of the many Customer Preference Selection features   which allow the customer the ability to fine tune the   controls.   Note: Remote Control is generally standard with a   “Ducted Unit”   Ducting and Ventilation Options   The ventilation system is ideal for ducting. The option-   al collars fit standard ventilation ducting allowing the   installer to vent air to and from the unit for optimum   performance (please see specifications for details).   Anti Short Cycle   The Anti Short Cycle ensures that the unit will remain   off for a period of 5 minutes after the unit has reached   the set point to allow the pressure in the refrigeration   system to equalize prior to starting the compressor.   Defrost Cycle   The Defrost Cycle is a precautionary measure, as icing   or frosting of the coil does not occur during normal   operation. The system will go through a defrost cycle   every 4 hours. During the defrost cycle, the indoor fan   will provide air flow across the indoor coil, which will   evaporate any frost accumulation.   Page 26   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   CONTROL PANEL FEATURES AND OPERATION   Button   Normal Functions   ON/OFF   • • The ON/OFF button allows the customer the convenience of turning the refrigeration system   ON or OFF, from the control panel. This feature does not disconnect power from the unit, and   the condenser fan will continue to run in the OFF position. In order for the power to be shut off   from the unit, the power cord must be unplugged from the wall receptacle.   Press the ON/OFF button once for button application.   Up and   Down   Arrows   • • Use these buttons to scroll up or down the CPSM menu.   Displays the Highest and Lowest temperature sensed by the Bottle Probe. This feature allows   the customer instant access to the recorded data applicable to the Bottle Probe Temperatures,   it can be easily reset to reflect current temperatures.   1. Press the “UP”arrow, or the “Down”arrow once, and the Highest or Lowest Temperature (Hi/Lo)   sensed by the Bottle Probe, will be displayed.   2. To reset the Hi/Lo, press and hold the “Set”button when the Hi/Lo value is displayed on the   Digital Display, continue to hold the “Set”button until “rst”appears on the digital display and then   blinks. This will erase the past recorded “Temperature Data History”and start recording, from the   current time and temperature, forward. Temperatures displayed would reflect Bottle Probe Tem-   peratures from that point in time, and beyond.   3. The Hi/Lo feature should be reset at initial “Start-Up”and after the Cellar or Cabinet has obtained   normal operating temperatures, which is generally 55°F.   Cellar   The CPC Feature is activated by pressing the Up button for 3-5 seconds, and the CPC logo will be   PreChill displayed on the digital display. The CPC feature can be terminated by pressing the Up button for   (CPC)   3-5 seconds, or the feature will self terminate after 6 hrs.   1. The (CPC) Feature may be used to Pre-Chill the Cellar prior to loading it with Warm Product. The   feature will shift the Set Point down to a lower setting of 52°F, for the next 6 hours. After the 6 hour   time period, the Set Point will automatically return to the original Set Point.   2. The CPC feature can be conveniently adjusted to the customer’s specific needs, by accessing the   “Customer Preference Select Mode”(CPSM). See Customer Preference Select Mode Instructions.   Note: This feature is not available on the Remote Key Pad application.   Page 27   Download from Www.Somanuals.com. All Manuals Search And Download.   Energy   Reduc-   tion   1. The ER feature can be used to save energy and aids in extending the life of the system.   2. The ER button is located at the top L/H side of the control. The ER feature is activated by press-   ing the ER button one time, and the ER logo will appear on the digital display.   3. The purpose of the ER feature is to reduce energy cost, by shifting the Set Point up by 4 degrees,   which will allow the cooling system to run for shorter periods of time, resulting in a reduction in   energy cost.   (ER)   4. The ER feature allows for Energy Savings at any time - During periods of high ambient tempera-   tures, vacations or business travel.   5. To deactivate the ER feature, press the ER button one time, and the ER logo will turn off.   6. The ER feature can be conveniently adjusted to the customer’s specific needs, by accessing the   “Customer Preference Select Mode”(CPSM). See Customer Preference Select Mode Instructions.   Note: This feature is not available on the Remote Key Pad application.   Set   Button   1. Press the “Set”button once and it will display the Set Point. After approximately 5 seconds, the   display will return to normal operation and display the Bottle Probe temperature.   2. Press and hold the “Set”button for 3-5 seconds until the set point is displayed and the °F symbol   starts blinking. Next press the “UP or Down”arrows to change the Set Point. Next press the “Set”   button once and the Set Point numbers and the °F on the display will blink to confirm the new Set   Point setting.   3. Press and hold the “Set”button during the display of the Hi/Low “Temperature Data History”   (hold button unit “rst”blinks on display), and it will erase the past recorded data file and start re-   cording, from the current time and temperature.   4. Press the “Set”and the “Down Arrow”buttons simultaneously, for 3-5 seconds, and you will ac-   cess the “Customer Preference Selection Mode”(CPSM). The CPSM allows the customer to “Fine   Tune”the Control Operating System to their applicable choice.   CPSM   Mode   Press the “Set”and the “Down Arrow”buttons simultaneously, for 3-5 seconds, and you will access   the “Customer Preference Selection Mode”(CPSM). The CPSM allows the customer to “Fine Tune”   the Control Operating System to their applicable choice.   The following CPSM options are available for adjustment:   Fon – Humidity Management Enhancement: This parameter is normally set at 5, which should   provide adequate relative humidity for the cellar.   • An increase in this parameter will increase the Humidity Enhancement (%RH), and a decrease in   the parameter will decrease Humidity Enhancement (%RH).   • • Adjustments should be made in increments of 5, with a maximum of 15, and a minimum of 0.   After any adjustment to Humidity Enhancement, you should wait a minimum of three days   before making any additional adjustments. This will allow the cellar sufficient time to acclimate   to the new setting.   Fof - Humidity Management Enhancement: This parameter is normally set at 1. This parameter   should not be adjusted, as it simply provides an OFF cycle time for the fan, during the compressor   OFF cycle. However, the parameter is located within the CPSM as a convenience to the customer,   should it need to be adjusted.   Page 28   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   CPSM   Mode   (Cont.)   CCS – Cellar Pre-Chill Set Point: This parameter is set at 52°f, but can be adjusted to a set point   between 45°f - 67°f.   bLL/Act – Compressor Off or On for Low (bLL) or High (Act) Temperature Alarm: These parameters   are set at “n”. With this parameter set at “n”the refrigeration system will continue to operate nor-   mally, if there is a High or Low temperature Alarm. To change this parameter, change the setting to   “y”, and the compressor/refrigeration system will shut off during a High or Low temperature Alarm.   Con/Cof – Compressor On time (Con) and Off time (Cof) with a Probe 1 failure/Alarm. These pa-   rameters are set at Con 40 min/Cof 10 min. In the event that there is a Probe 1 failure/Alarm, the   compressor/refrigeration system automatically starts a predetermined ON/OFF cycle, which is con-   trolled by the Con and the Cof parameters. The customer can adjust these parameters to maintain   the desired Bottle Probe temperature. During a Probe 1 failure/Alarm, the Bottle Probe tempera-   ture can be monitored by pressing the Up or Down arrow to view the High and Low Temperature   History.   Hes – Differential for Energy Reduction – This parameter is set at 4, which results in a set point of   58°f during the Energy Reduction mode. A decrease in this setting will decrease the set point, and   an increase in this feature will increase the set point.   AUX   “AUX”indicates that the condenser fan is running. Pressing the “AUX”button on the control panel   will turn it off.   Alarm Codes   Message   “P1”   Cause   Outputs   Toggle “Con” and “COF” based on your temperature needs   Defrost end is timed   Room probe failure   “P2”   Evaporator probe failure   Condenser probe failure   Max bottle probe temp alarm   Min bottle probe temp alarm   Condenser high temperature   Condenser low temperature   External alarm   “P3”   Outputs unchanged   “HA”   Outputs unchanged   “LA”   Outputs unchanged   “HA2”   “LA2”   “EA”   It depends on the “Ac2” parameter   It depends on the “bLL” parameter   Outputs unchanged   “POF”   Keypad locked   Hold “Up” and “Down” buttons for 3 to 5 seconds to disable,   “PON” should appear   Page 29   Download from Www.Somanuals.com. All Manuals Search And Download.   MAINTENANCE SCHEDULE   Monthly 1. Check filters   2. Check for unusual noise or vibration   Quarterly Clean filters:   1. Remove grille/ducting on both ends of unit.   2. Remove the filter covering the coil.   3. Wash with warm water   4. Dry off filter by shaking excess water from filter.   1. Replace filters if worn or plugged beyond cleaning.   2. Use a vacuum with brush attachment to clean coils. Be careful not to crush coil fins   when cleaning.   Annually   3. Inspect for corrosion.   4. Check wiring connections and integrity of cords.   5. Examine duct work for cracks or possible leaks.   Page 30   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   TROUBLESHOOTING GUIDE   Unit has ice forming on the evaporator   Possible Cause   Solution   Evaporator filter and/or coil are dirty.   There is something blocking the supply and or return air   One or both evaporator fans are not turning on.   The temperature of the room, the unit is exhausting to,   has dropped below 50°   Clean filter and coil with a vacuum.   Remove blockage   Call a service tech to troubleshoot   Raise the temperature of the exhaust room   The unit has not went through its defrost sequence, yet.   If unit continues to ice.   Wait 10 minutes to see if ice disappears   Call Customer Service at 800-343-9463   Unit does not run/power up   Possible Cause   Solution   Unit is not plugged in   Make sure the unit is plugged into an outlet   Turn unit on by pressing the power button on the control   Reset circuit breaker on unit by pushing reset button located on   right side of unit above the plug outlet   Check line voltage to make sure there is 110v/120v   Lower set point   Power switch not on   No power to outlet   Line voltage is incorrect rating for unit   Room at set point   Thermostat not calling for cooling   Faulty thermostat or writing   Lower set point   Call Customer Service at 800-343-9463   Cellar Temperature is to Too Cold   Possible Cause   Solution   Lower the temperature of the exhaust room.   The temperature or the room unit is exhausting to has   exceeded 85°   The unit is undersized for the room.   There is something blocking the supply and/or return air,   on evaporator or condenser side of the unit   Unit is mounted too low in the cellar   Order correct size unit   Remove air flow obstruction   Re-Locate unit so the distance from the ceiling and top of the   unit is no more than 18”   One or more of the fans is not turning on.   Compressor is not turning on.   Call Customer Service at 800-343-9463   Call Customer Service at 800-343-9463   Make sure all fans are working and there are no airflow   obstruction.   Compressor keeps cycling on overload   Poor seal around door.   Controller set too high   Make sure there are no air gaps around the door. If door seal is   damaged, replace it.   Lower the set point.   Unit leaks water   Possible Cause   Unit is not level   Solution   Unit should be level in wall to prevent leaking   Check drain line to make sure water can flow freely.   Clear Drain   Drain line clogged or kinked   Drain is clogged preventing water form escaping   Drain line does not have a downward slope   Fix Drain line so there is a downward slope from the   unit to the drain.   Page 31   Download from Www.Somanuals.com. All Manuals Search And Download.   TROUBLESHOOTING GUIDE   Unit runs but does not cool   Possible Cause   Solution   Lack of air flow/heat exhaust (outer room)   Crankcase pressure set too high/low   Compressor not running   Make sure fan is unobstructed; clean evaporator if necessary   Call Customer Service at 800-343-9463   Call Customer Service at 800-343-9463   Unit undersized   Call Customer Service at 800-343-9463   Evaporator fan runs but compressor does not   Possible Cause   Solution   Call Customer Service at 800-343-9463   Compressor and/or starting components faulty   Compressor runs; evaporator fan motor does not   Possible Cause   Solution   Replace fuse/reset breaker   Call Customer Service at 800-343-9463   Call Customer Service at 800-343-9463   Blown fuse or circuit breaker   Faulty fan motor   Faulty fan relay   Compressor short cycles   Possible Cause   Solution   Evaporator blows on thermostat   Dual pressure control improperly set   Unit low on refrigerant charge   Move thermostat   Call Customer Service at 800-343-9463   Call Customer Service at 800-343-9463   Call Customer Service at 800-343-9463   Call Customer Service at 800-343-9463   Condensing fan motor/capacitor faulty   Compressor and /or starting components faulty   Solution   Install proper vapor barrier   Humidity in cellar too low   Possible Cause   Cellar vapor barrier not sufficient   Page 32   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   TECHNICAL ASSISTANCE   WhisperKOOL Customer Service is available Monday through Friday from 8:00 a.m. to 4:00 p.m. PST.   The customer service representative will be able to assist you with your questions and warranty information   more effectively if you provide them with the following:   • • The model and serial number of your WhisperKOOL Series Unit.   Location of unit and installation details, such as ventilation, ducting, construction of your wine cellar,   and room size.   Contact WhisperKOOL Customer Service   1738 E. Alpine Avenue   Stockton, CA 95205   Email: [email protected]   Phone: (209) 466-9463   US Toll Free (800) 343-9463   Fax (209) 466-4606   Page 33   Download from Www.Somanuals.com. All Manuals Search And Download.   INSTALLATION TERMS AND CONDITIONS   WhisperKOOL Extreme Cooling System   ATTENTION: PLEASE READ THESE TERMS OF USE CAREFULLY BEFORE INSTALLING YOUR WhisperKOOL Slimline/   Cooling System. INSTALLING YOUR WhisperKOOL Slimline/ Cooling System INDICATES THAT YOU ACCEPT AND   AGREE TO EACH OF THE TERMS AND CONDITIONS SET FORTH HEREIN (“TERMS OF USE”). IF YOU DO NOT ACCEPT   THESE TERMS OF USE, YOU RISK VOIDING YOUR WARRANTY AND ASSUMING ADDITIONAL REPAIR AND REPLACE-   MENT COSTS.   1. Acceptance of Terms and Conditions Use and installation of a WhisperKOOL Slimline/ Cooling System assumes   that the consumer, (“user”) fully accepts and agrees to the Terms and Conditions set forth in this document. The   Terms and Conditions also state that, by signing and returning this document, you are certifying you have read,   understood, and agreed to our Terms and Conditions, as well as our User’s Manual. The User’s Manual is shipped   with each unit and, if another copy is needed, replacement copies can be downloaded from the company website   its sole discretion, to change its Terms and Conditions at any time, for any reason, without notice.   2. Product Installation Subject to these Terms and Conditions, when the user purchases a WhisperKOOL Slimline/   Cooling System, the user agrees to read and follow the required installation procedures set forth by WhisperKOOL   for proper use and installation of the Product.   (a) It is highly recommended that you obtain the assistance of a wine storage professional.   (b) Failing to address all of the variables associated with proper installation will cause the unit to operate incorrectly   and limit its ability to cool and the longevity of the unit itself.   (c) The warranty card must be returned to WhisperKOOL, the manufacturer, to ensure registration guaranteeing the   full warranty period is granted. Failure to register the product within thirty (30) days of installation may result in a   loss of warranty.   (d) The user is responsible for the full costs of installation and any additional parts required for the proper and com-   plete installation of the Product.   (e) The WhisperKOOL Slimline cooling system cannot operate at its optimum capacity if airflow is constricted by   ducting or venting the exhaust side of the unit into a location with inadequate ventilation.   3. Product Warranty Information If a problem arises with your WhisperKOOL system during the warranty period, you   must contact WhisperKOOL Customer Service for warranty coverage and repairs.   Removing the rivets from the unit housing without authorization from the manufacturer will VOID the warranty.   Please contact a customer service representative for assistance before beginning work on a WhisperKOOL unit that   is still under the two (2) year manufacturer warranty.   For Slimline/ Cooling Systems returned to WhisperKOOL following warranty guidelines, WhisperKOOL warrants this   product against defects in material or workmanship as follows:   (a) LABOR: For a period of two (2) years from the date of purchase. If this Product is found to be defective after   undergoing customer service troubleshooting, WhisperKOOL will repair or replace the product, at its option and   discretion, at no charge to the customer. After the Warranty Period, the customer is responsible for ALL labor and   freight charges.   (b) PARTS: WhisperKOOL will supply, at no charge, new or rebuilt replacement parts in exchange for defective parts   for a period of two (2) years.   (c) FREIGHT: During the first two (2) years from the date of purchase, WhisperKOOL will cover freight for the repair   of units UNDER WARRANTY to customers within the continental United States.   This warranty does not cover cosmetic damage caused during installation or damage due to acts of God, accident,   misuse, abuse, negligence, or modification to any part of the product. This warranty does not cover damage due to   improper operation or lack of proper maintenance, connection to improper voltage   supply, or attempted repair by anyone other than a technician approved by WhisperKOOL to service the product.   This warranty does not cover products sold “AS IS”or “WITH ALL FAULTS.”This warranty is valid only in the continen-   tal United States.   Page 34   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   Proof of purchase in the form of a bill of sale or receipted invoice, which is evidence that the product is within the   warranty period, must be presented to obtain warranty service. This warranty is void if the factory-applied serial   number has been altered or removed from the product.   REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER.   WhisperKOOL SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY   EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW,   ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS   LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some states do not allow the exclusion or limitation   of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above   limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may have other   rights which vary from state to state.   4. Maintenance It is the user’s responsibility to remove any accumulated dust, lint, or other debris from the front   and rear intake grilles. This will restrict the airflow and may affect the unit’s ability to function properly. Periodically   cleaning the unit’s vents will help assure maximum cooling efficiency. The drain tube must also be checked and   kept clean and free of debris and mold to maintain proper performance. Mold is a natural living organism in the   environment. It exists in the air in the form of microscopic spores that move in and out of buildings through doors,   windows, vents, HVAC systems and anywhere else that air enters. Once it is discovered, mold must be addressed   quickly and appropriately. Delayed or improper treatment of mold issues can result in costly and recurring repairs.   If you suspect you have a mold problem, it is always best to hire a qualified and experienced mold remediation   specialist.   5. User Costs and Responsibility The following items are not covered under warranty and are the sole responsibility   of the user.   (a) The user is responsible for ALL initial installation costs, including, but not limited to, labor costs and the cost of   any additional parts necessary to complete the installation.   (b) The user is responsible for the costs incurred for installation and removal of the product or any part thereof un-   less it has been defined as a warranty repair PRIOR to the work being performed.   (c) Purchasers (users) are reminded that they should satisfy themselves that the product they are purchasing is suit-   able for their needs and requirements and no responsibility will be placed with WhisperKOOL for their decisions.   (d) It is the user’s responsibility to secure safe haven/storage for ANY AND ALL items that are being kept and stored   in the user’s wine cellar. WhisperKOOL takes no responsibility for the safety and preservation of the aforementioned   items in the event that the environment becomes unsuitable for proper storage.   6. State Sales Tax   We collect California Sales Tax only for orders made and shipped within California. We do not collect sales tax for or-   ders shipped to other states. However, you may be liable for sales tax to your state for the merchandise you receive.   You may want to check with your state’s tax authority for “use tax”regulations.   7. Customer Service WhisperKOOL customer service department is available Monday through Friday, from 8:00AM   to 4:00PM PT by calling 1-800-343-9463.   8. Trouble Shooting The customer service department is available to answer any questions or inquiries regarding   our product as well as to assist in basic and primary troubleshooting for any problems with our product.   9. General Provisions   (a) Construction and severability. Every provision of these Terms and Conditions will be construed, to the extent   possible, so as to be valid and enforceable. If any provision of these Terms and Conditions so construed is held by a   Page 35   Download from Www.Somanuals.com. All Manuals Search And Download.   court of competent jurisdiction to be invalid, illegal or otherwise unenforceable, such provision will, to the extent   so held, be deemed severed from these Terms and Conditions, and all other provisions will remain in full force and   effect.   (b) Governing Law/Choice of Forum. The laws of the State of California (without regard for conflicts of law) shall   govern the construction and enforcement of these Terms and Conditions, except that the Terms and Conditions   shall be interpreted as though drafted jointly by WhisperKOOL and the Purchaser. Any dispute will be resolved in a   state or federal court situated in the County of Santa Clara, State of California, and the Purchaser hereby irrevocably   submits to the personal jurisdiction of such courts for that purpose.   (c) Entire Agreement/No Waiver. These Terms and Conditions and the Limited Warranty incorporated herein by   reference set forth the entire agreement between the parties and supersede all prior agreements or understand-   ings, both written and oral, between the parties regarding the subject matter of this the Terms and Conditions and   the Limited Warranty. The parties may modify these Terms and Conditions or the Limited Warranty only in a writing   signed by each. No waiver by WhisperKOOL of any breach or default hereunder will be deemed to be a waiver of   any preceding or subsequent breach or default.   (d) Correction of Errors and Inaccuracies. These Terms and Conditions may contain typographical errors or other er-   rors or inaccuracies. WhisperKOOL reserves the right to correct any errors, inaccuracies or omissions, and to change   or update these Terms and Conditions, at any time, without prior notice.   10. Questions or Additional Information If you have any questions regarding these Terms and Conditions or wish to   obtain additional information, contact us via phone at 1-800-343-9463 or please send a letter via U.S. Mail to:   WhisperKOOL   1738 E. Alpine Ave   Stockton, CA 95205   Page 36   PT-EXPL 072010   Download from Www.Somanuals.com. All Manuals Search And Download.   NOTES   Download from Www.Somanuals.com. All Manuals Search And Download.   WhisperKOOL   1738 E. Alpine Ave   Stockton, CA 95205   1(800) 343-9463   Download from Www.Somanuals.com. All Manuals Search And Download.   |