ECOiTM
Variable Refrigerant Flow (VRF),
Multi-Zone, Heat Pump & Heat Recovery Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
SANYO's Brand Vision
SANYO HVAC consistently builds new ideas to help build
your business. By delivering multi-zone options, space-saving
and environmentally friendly designs, our solutions are evolving,
improving solutions.
Flexible Combinations: ECOi allows multiple indoor unit
combinations that provide you with the utmost in flexible
solutions. The system also allows multiple unit connectivity
providing up to 130% of the total capacity of the condensing
unit. This provides for up to 17 indoor units connected to one
condensing unit.
Inverter Control Compressor: All ECOi systems utilize highly
advanced inverter controlled compressor technology. By varying
the rotational speed of the compressor, the inverter control can
precisely match the amount of refrigerant being delivered to
the needs of each zone. This intelligent approach helps realize
excellent efficiencies during partial-load conditions. This allows
all occupants to enjoy consistent room temperature, regardless
of any increases or decreases in the heat load during the day.
ECOi quite simply knows what you need, and when you need
it throughout the day. And even better, it does so with energy
efficiency in mind.
ECOi™.
Building
Lower running and life cycle costs: SANYO Ecoi VRF
systems are amongst the most efficient VRF systems on the
market, offering COPs in excess of 4.0 at full load conditions.
The system is also designed to make sure that we reduce the
running cost of each system by using our unique road map
control routine to ensure that the most efficient combination
of compressors are running at any one time. Improved defrost
sequencing also reduces running cost by defrosting each out
door coil in turn when conditions allow.
Your Business.
SANYO has a proud global heritage and over 25 years
experience in the United States. By delivering more multi-zone
options, space-saving designs and offering solutions protect
the environment. Our products reduce your energy costs and
create a more comfortable environment.
Today every conditioning solution must answer multitudes
of project needs, including tighter budgets, flexibility, energy
efficiency and ease of installation, to name a few. ECOi is the
answer. It’s an all-in-one solution that responds to the many
commercial and residential applications.
03
Download from Www.Somanuals.com. All Manuals Search And Download.
For the Living
Inside & Out.
Contractors. Building Support.
At SANYO, we realize contractors are looking for turnkey
installation and support. ECOi™ is quite simply the perfect
building solution. With its modular design and ease of
installation, it’s a solution that can grow with any building
project. In fact, ECOi may just make you remember why you
got into the business in the first place.
grow with you. As remodeling occurs and building extensions are
planned, ECOi’s modularity lets you simply add on to the system.
With intelligent controllers, VRF technology and R410A refrigerant,
ECOi guarantees continued energy savings and environmental
friendship for years to come.
ECOi™.
Your Building
Life Tool.
Engineers. Designing Confidence.
ECOi™ is absolute confidence. Its flexibility allows
multiple applications and installation configurations. With
a maximum pipe length of up to 984 feet and up to 40
units connected to one outdoor system you can engineer
a perfect solution for all your project needs. ECOi is a
superior modular option that provides for floor-by-floor
commissioning.
ECOi has a number of diverse features to meet all your
conditioning needs, including: Flexible Combinations: ECOi
allows multiple indoor unit combinations that provide you with
the utmost in flexible solutions. The system also allows multiple
unit connectivity providing up to 130% of the total capacity of the
condensing unit. This provides for up to 17 indoor units connected
to one condensing unit.
Architects. Design Freedom.
Now There’s An Idea.
Of course, nobody understands this more than the
architects who design them. That’s why the ECOi HVAC
system provides more freedom to meet any design need.
With space saving designs, environmental friendship and
ultimate efficiency, you can design your vision first then
marry our system fluidly within your plans.
Inverter Control Compressor: All ECOi systems utilize highly
advanced inverter controlled compressor technology. By varying
the rotational speed of the compressor, the inverter control can
precisely match the amount of refrigerant being delivered to
the needs of each zone. This intelligent approach helps realize
excellent efficiencies during partial-load conditions. This allows all
occupants to enjoy consistent room temperature, regardless of any
increases or decreases in the heat load during the day. ECOi quite
simply knows what you need, and when you need it throughout the
day. And even better, it does so with energy efficiency in mind.
Owners & Tenants.
With immediate response to changing room capacity
heat loads and varying sun exposures throughout the day,
everybody stays cool and comfortable. ECOi also ensures
individual zone temperature control so each office or
room can be adjusted for personalized comfort. ECOi can
04
Download from Www.Somanuals.com. All Manuals Search And Download.
3-Way ECOiTM VRF Heat Recovery
CHDZSERIES
Commercial office buildings are subject to fluctuating heat levels generated from electronic office equipment,
lighting and varying occupant levels. Also, hotels, nursing homes and other commercial living spaces often have
times when occupants will want either heating or cooling at the same time. The heat recovery system offers the
perfect solution for stabilizing the air temperature by providing all the features of a heat pump system - and the
added flexibility of simultaneous cooling and heating from one refrigerant pipe network.
For the buildings requiring simultaneous heating and cooling,
SANYO 3-Way ECOi™ system provides the perfect solution
2- Way ECOiTM VRF Heat Pump
CHDXSERIES
SANYO’s Combined ECOi 2-Way conditioning solution offers superior heating and cooling coupled with cost effective
installation. A smart conditioning solution for large capacity jobs.
Cooling
Heating
05
Download from Www.Somanuals.com. All Manuals Search And Download.
3-Way ECOi VRF Heat Recovery
CHDZSERIES
CHDZ 07263 / CHDZ (R)07263
CHDZ 09663 / CHDZ (R)09663
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* Heat Recovery system simultaneous heating-cooling
* One Outdoor Unit Connects As Many As 17 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* Heat Pump
* One Outdoor Unit Connects As Many As 17 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* CHDZ07263 includes one inverter driven Rotary compressor
* CHDZ09663 includes one inverter driven Rotary compressor
and one AC Constant Speed Scroll Compressor
* Operating Range (Outdoor Ambient)
- Cooling 14 FDB to 113 FDB
- Heating -4 FWB to 59 FWB
SANYO’s ECOi Heat Recovery series offers
the ability to heat and cool different
zones simultaneously.
SANYO was the first manufacturer in the
world to develop this energy saving heat
recovery solution. Offering all the features
of our standard heat pump series, the 3-Way
solution can offer even higher energy savings
for the building owner.
* Ultra Quiet Operation As Low As 51.5dB(a)
* Variable Speed DC Fan Motor (ESP adjustable to 0.25” wc)
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Below Indoor)
(Type: Nominal Cooling Capacity, etc)
Volt
PH
3
MODELS
72,000 BTU Heat Recovery
208-230V/60 HZ
CHDZ 07263
72,000 BTU Heat Recovery
With Salt Protection - Special Order
208-230V/60 HZ
3
CHDZ R07263
96,000 BTU Heat Recovery
208-230V/60 HZ
208-230V/60 HZ
3
3
CHDZ 09663
96,000 BTU Heat Recovery
With Salt Protection - Special Order
CHDZ R09663
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
06
Download from Www.Somanuals.com. All Manuals Search And Download.
3-Way ECOi VRF Heat Recovery CHDZSERIES
DESCrIPtION
CHDZ (R) 07263
CHDZ (R) 09663
PErFOrMaNCE
COOLINg CAPACITY: BTU/H
POWER INPUT: KW
72,000
5.3
96,000
7.75
HEATINg CAPACITY: BTU/H
POWER INPUT: KW
81,000
5.79
108,000
8.6
ELECtrICaL ratINGS
VOLTAgE RATINg
COOLINg RUNNINg AMPERES
HEATINg RUNNINg AMPERES
MIN. CIRCUIT AMPACITY
MAX. CIRCUIT AMPACITY
208
15.1
16.5
24
-
-
-
230
14.2
15.5
V
A
A
208
23.2
25.4
34
-
-
-
230
21.6
23.7
A
A
V
A
A
A
A
40
45
COMPrESSOr
TYPE - QUANTITY
MOTOR OUTPUT
Inverter Driven Rotary Type
4.1 kw
Inverter Driven Rotary 1 FixedScrollHermetic
(2.7 + 3.5) kw
REFRIgERATION OIL TYPE
REFRIgERATION OIL CHARgE AMOUNT
CRANKCASE HEATER
FV68S (Ether oil - PVE)
1.4 gal
25 w
FV68S (Ether oil - PVE)
1.96 gal
25 + 32 w
REFRIgERANT AMOUNT AT SHIPMENT
REFRIgERANT CONTROL
DEFROST METHOD
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%
HEAT EXCHANgER
CAPACITY CONTROL
FaN DEVICE
TYPE - QUANTITY
Propeller fan x 1
Propeller fan x 1
MOTOR OUTPUT
0.7 kw
0.7 kw
PROTECTIVE DEVICES
CFM
High pressure switch, overcurrent (CT method)
5.300
High pressure switch, overcurrent (CT method)
5.650
EXTERNAL STATIC PRESSURE
0.04 / 0.25
0.04 / 0.25
tuBING
REFRIgERANT TUBINg gAS TUBE
REFRIgERANT TUBINg LIQUID TUBE
REF. TUBINg DISCHARgE TUBE
3/4" (Brazing)
ø3/8" (Brazing)
ø5/8" (Brazing)
ø7/8" (Brazing)
ø3/8" (Brazing)
ø3/4" (Brazing)
REFRIgERANT TUBINg BALANCE TUBE
EXTERNAL AIR TEMP. OPERATION RANgE
OPERATION SOUND (HI)
ø3/8" (Flare)
Cooling: 14 to 109 (DB) / Heating: -4 to 59 (WB) °F
54.5 (Quiet mode: 51.5) dB-A
ø3/8" (Flare)
Cooling: 14 to 109 (DB) / Heating: -4 to 38 (WB) °F
55.0 (Quiet mode: 52.0) dB-A
uNIt DIMENSIONS
Inches (") / lbs.
Color (Munsell code)
81.5"/ 35"/ 35"/ 573 lbs.
Height/ Width/ Depth/ Net Weight
Silky shade (1y 8.5/0.5)
82"/ 35"/ 35"/ 672 lbs.
Height/ Width/ Depth/ Net Weight
Silky shade (1y 8.5/0.5)
(R) indicates with salt protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
07
Download from Www.Somanuals.com. All Manuals Search And Download.
3-Way ECOi VRF Heat Recovery Combined Units
WCHDZSERIES
WCHDZ 14463 / WCHDZ 16863 / WCHDZ 19263
WCHDZ 21663 / WCHDZ 24063
WCHDZ 26463 / WCHDZ 28863
KEy FEaturES:
* Three-Way Heat Recovery
* Combine 3 outdoor units up to 24 tons
* “ECO Friendly” R410A Refrigerant
* 208/230V, 3 Phase, 60Hz
* Multiple Compressors For Extra Reliability and Partial Redundancy
* Operating Range (Outdoor Ambient)
-Cooling 14 FDB to 113 FDB
-Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 52dB(a)
* Variable Speed DC Fan Motors
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Below Indoor)
SANYO’s Combined ECOi 3-Way conditioning solution offers
superior heating and cooling coupled with cost effective
installation. Providing a single refrigerant pipe network means
there’s only one penetration into the building and ultimately
less piping material required, saving you time and money.
A smart conditioning solution for large capacity jobs that
require simultaneous heating and cooling.
WCHDZ HEAT RECOVERY COMBINED SERIES.
Outdoor Unit
Cooling & Heating
Power input
10.56/ 11.58 kW
12.97/ 14.39 kW
Control Range
6 - 100%
SyStEM
WCHDZ 14463
WCHDZ 16863
CHDZ 07263 (quantity of 2)
144,000 & 162,000 BTU/H
168,000 & 189,000 BTU/H
CHDZ 07263
CHDZ 09663
6 - 100%
CHDZ 09663 (quantity of 2)
192,000 & 216,000 BTU/H
216,000 & 243,000 BTU/H
240,000 & 270,000 BTU/H
15.38/ 17.2 kW
15.84/ 17.37 kW
18.25/ 20.18 kW
6- 100%
6 - 100%
6- 100%
WCHDZ 19263
WCHDZ 21663
WCHDZ 24063
CHDZ 07263 (quantity of 3)
CHDZ 07263 (quantity of 2)
CHDZ 09663
WCHDZ 26463
CHDZ 09663 (quantity of 2)
CHDZ 07263
264,000 & 297,000 BTU/H
288,000 & 324,000 BTU/H
20.66/ 22.99 kW
23.07/ 25.8 kW
6 - 100%
6 - 100%
WCHDZ 28863
CHDZ 09663 (quantity of 3)
(R) indicates with salt protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
08
Download from Www.Somanuals.com. All Manuals Search And Download.
3-Way ECOi VRF Heat Recovery Combined Units
WCHDZSERIES
DESCrIPtION
WCHDZ 14463 WCHDZ 16863
WCHDZ 19263
includes (1) CHDZ07263
and (1) CHDZ07263
includes (1)CHDZ07263 and
(1) CHDZ09663
includes (1) CHDZ09663
and (1) CHDZ09663
PErFOrMaNCE
COOLINg CAPACITY: BTU/H 144,000
168,000
12.97
192,000
15.38
POWER INPUT: KW 10.56
HEATINg CAPACITY: BTU/H 162,000
POWER INPUT: KW 11.58
189,000
14.39
216,000
17.2
COOLING MODE NOMINaL CONDItIONS
INDOOR: °F WB/ °F DB 80/67
80/67
95
80/67
95
OUTDOOR: °F DB 95
PIPE LENgTH: FEET 25
25
25
LEVEL DIFFERENCE: FEET
0
0
0
HEatING MODE NOMINaL CONDItIONS
INDOOR: °F DB 70
OUTDOOR: °F DB/ °F WB 47/43
PIPE LENgTH: FEET 25
70
47/43
25
70
47/43
25
LEVEL DIFFERENCE: FEET
0
0
0
OPEratING raNGE
COOLINg: °F DB 14 to 113
HEATINg: °F WB -4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
COMPrESSOr
TYPE/QUANTITY 2 Inverter driven Rotary
2 Inverter driven Rotary
& 1 fixed speed scroll
6 - 100%
2 Inverter driven Rotary
& 2 fixed speed scroll
6- 100%
CAPACITY CONTROL RANgE: % 6 - 100%
FaN
TYPE/QUANTITY 1 Propeller (ea)
FAN MOTOR OUTPUT: (KW) 0.7 kW (ea)
EXTERNAL STATIC PRESSURE .04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
POwEr SuPPLy
V/PH/HZ 208 - 230/ 3/ 60
208 - 230/ 3/ 60
208 - 230/ 3/ 60
MINIMUM CIRCUITS AMPS (MCA): (A) 52
MAX. OVERCURRENT PROTECTION (MOCP): (A) 80
60
85
68
90
wEIGHt: (LBS) 1168
1267
1366
COIL:
COIL FACE AREA:(SQ. FT.) 29.5(ea)
29.5(ea)
4(ea)
29.5(ea)
4(ea)
NUMBER OF ROWS: 4(ea)
PrOtECtION DEVICES
HIgH PRESSURE SWITCH/OVERCURRENT
Yes
(CT METHOD)
Yes
25 + 25 + 32
Yes
25 + 32 X 2
25 + 25
CRANKCASE HEATERS:(W)
EACH OUTDOOR UNIT REQUIRES A SEPARATE ELECTRICAL FUSED DISCONNECT,
SEE INDIVIDUAL OUTDOOR REQUIREMENTS.
(R) indicates with salt protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
09
Download from Www.Somanuals.com. All Manuals Search And Download.
3-Way ECOi VRF Heat Recovery combined units
WCHDZSERIES
WCHDZ
21663
WCHDZ
24063
WCHDZ
26463
WCHDZ
28863
DESCrIPtION
includes (3)
CHDZ07263
includes (2)
CHDZ07263 and (1)
CHDZ09663
includes (1)
CHDZ07263 and (2)
CHDZ09663
includes (3)
CHDZ09663
PErFOrMaNCE
COOLINg CAPACITY: BTU/H 216,000
240,000
18.25
264,000
20.66
288,000
23.07
POWER INPUT: KW 15.84
HEATINg CAPACITY: BTU/H 243,000
POWER INPUT: KW 17.37
270,000
20.18
297,000
22.99
324,000
25.8
COOLING MODE NOMINaL CONDItIONS
INDOOR: °F WB/ °F DB 80/67
80/67
95
80/67
95
80/67
95
OUTDOOR: °F DB 95
PIPE LENgTH: FEET 25
25
25
25
LEVEL DIFFERENCE: FEET
0
0
0
0
HEatING MODE NOMINaL CONDItIONS
INDOOR: °F DB 70
OUTDOOR: °F DB/ °F WB 47/43
PIPE LENgTH: FEET 25
70
47/43
25
70
47/43
25
70
47/43
25
LEVEL DIFFERENCE: FEET
0
0
0
0
OPEratING raNGE
COOLINg: °F DB 14 to 113
HEATINg: °F WB -4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
COMPrESSOr
TYPE/QUANTITY 3 Inverter driven Rotary 3 Inverter driven Rotary 3 Inverter driven Rotary 3 Inverter driven Rotary
& 1 fixed speed scroll
6 - 100%
& 2 fixed speed scroll
6 - 100%
& 3 fixed speed scroll
6 - 100%
CAPACITY CONTROL RANgE: % 6 - 100%
FaN
TYPE/QUANTITY 1 Propeller (ea)
FAN MOTOR OUTPUT: (KW) 0.7 kW
EXTERNAL STATIC PRESSURE .04 / .25
1 Propeller (ea)
0.7 kW
.04 / .25
1 Propeller (ea)
0.7 kW
.04 / .25
1 Propeller (ea)
0.7 kW
.04 / .25
POwEr SuPPLy
V/PH/HZ 208 - 230/ 3/ 60
208 - 230/ 3/ 60
208 - 230/ 3/ 60
208 - 230/ 3/ 60
MINIMUM CIRCUITS AMPS (MCA): (A) 78
MAX. OVERCURRENT PROTECTION (MOCP): (A) 120
86
125
94
130
102
135
wEIGHt: (LBS) 1752
1851
1950
2049
COIL:
COIL FACE AREA:(SQ. FT.) 29.5(ea)
29.5 (ea)
4
29.5 (ea)
4
29.5 (ea)
4
NUMBER OF ROWS: 4(ea)
PrOtECtION DEVICES
HIgH PRESSURE SWITCH/OVERCURRENT (CT
Yes
METHOD)
Yes
Yes
Yes
3 X 25 + 32
25 + 25 + 25
25 + 25 + 25 + 32
(2 X 25 + 32) + 25
CRANKCASE HEATERS:(W)
EACH OUTDOOR UNIT REQUIRES A SEPARATE ELECTRICAL FUSED DISCONNECT,
SEE INDIVIDUAL OUTDOOR REQUIREMENTS.
(R) indicates with salt protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Mini ECOi Multi Split VRF Heat Pump
CHXSERIES
CHX (R) 03652 / CHX (R) 05252
KEy FEaturES:
* Single Phase 208/230 volts
* One Outdoor Unit Connects As Many As 9 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* Inverter Driven Twin Rotary Compressor
* Operating Range (Outdoor Ambient)
- Cooling 14 FDB to 113 FDB
- Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 51dB(a)
* Variable Speed DC Fan Motor
* Piping:
-656 Feet - Maximum Total Liquid Line
-164 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Above Indoor)
-131 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Below Indoor)
* Defrost control, Reverse cycle, microprocessor control
* External finish: galvanized steel plate with powder paint
* Refrigerant control: Electronic expansion valve
SANYO’s Mini ECOi is suited
for numerous commercial and
premium residential applications.
DESCrIPtION
CHX (R) 03652
CHX (R) 05252
POwEr SOurCE 208-230V/1PH/60Hz
208-230V/1PH/60Hz
PErFOrMaNCE Ducted Non-Ducted Mix
Ducted
51,500
14.6
57,500
7.7
Non-Ducted
52,000
17.3
58,000
9.5
Mix
51,500 BTU/H
16
58,500 BTU/H
8.6
COOLINg CAPACITY 40,000
39,000
16.40
42,500
9.60
39,000 BTU/H
SEER 14.20
15.30
HEATINg CAPACITY 40,500
HSPF 8.20
41,500 BTU/H
8.90
AIR CIRCULATION (HI)
3,530 CFM
3,530 CFM
ELECtrICaL ratINGS COOLINg
VOLTAgE RATINg 208 / 230 V
HEATINg
208 / 230 V
187—253 V
14.6 / 13.6 A
23.6 / 23.6 A
2.88 / 2.88 Kw
4.85 / 4.85 Kw
18 A
COOLINg
HEATINg
208 / 230 V
187—253 V
23.5 / 21.9 A
28 / 28 A
4.58 / 4.58 Kw
5.7 2 / 5.72 Kw
29 A
208 / 230 V
187—253 V
23.5 / 21.9 A
28 / 28 A
4.57 / 4.57 Kw
5.72 / 5.72 Kw
AVAILABLE VOLTAgE RANgE 187—253 V
RUNNINg AMPERES 14.6 / 13.6 A
MAX. RUNNINg AMPERES 23.6 / 23.6 A
POWER INPUT 2.76 / 2.76 Kw
MAX. POWER INPUT 4.85 / 4.85 Kw
MIN. CIRCUIT AMPACITY
MAX CIRCUIT AMPACITY
30 A
50 A
rEFrIGEraNt tuBING
LIMIT OF TUBINg LENgTH
656 ft
656 ft
LIMIT OF ELEVATION DIFFERENCE Outdoor unit is higher than indoor unit: 164
BETWEEN THE 2 UNITS Outdoor unit is lower than indoor unit: 131
Outdoor unit is higher than indoor unit: 164
Outdoor unit is lower than indoor unit: 131
rEFrIGEraNt tuBE DIaMEtEr
LIQUID TUBE IN.
gAS TUBE IN.
3/8"
5/8"
3/8"
3/4"
uNIt DIMENSIONS Height/ Width/ Depth/ Net Weight
INCHES (") / LBS. 49”/ 37”/ 14”/ 229 lbs.
Height/ Width/ Depth/ Net Weight
49”/ 37”/ 14”/ 229 lbs.
247 lbs. / 19.8 ft.3
SHIPPINg WEIgH / VOLUME 247 lbs. / 19.8 ft.3
EXTERNAL AIR TEMP. OPERATION RANgE Cooling:14 to 113 (DB)/Heating: -4 to 59 (WB) Cooling:14 to 113 (DB)/Heating: -4 to 59 (WB)
* NOtE: *(r) in Model # indicates Salt Protection - Special Order
11
Download from Www.Somanuals.com. All Manuals Search And Download.
2-Way ECOi VRF Heat Pump
CHDXSERIES
CHDX 07263 / CHDX (R) 07263
CHDX 09663 / CHDX (R) 09663
KEy FEaturES:
* One Outdoor Unit Connects As Many As 17 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* CHDX07263 one Inverter Driven Rotary Compressor
* CHDX09663 includes one Inverter Driven Rotary Compressor
and One AC Constant Speed Scroll Compressor
* Operating Range (Outdoor Ambient)
- Cooling 14 FDB to 113 FDB
- Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 52dB(a)
* Variable Speed DC Fan Motor (ESP adjustable to 0.25” wc)
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Below Indoor)
SANYO’s ECOi is an all-in-one modular
conditioning solution. Suited for
numerous commercial and industrial
applications it offers flexible installation,
superior heating and cooling.
(R) indicates with salt protection - Special Order
(Type: Nominal Cooling Capacity, etc)
Volt
PH
DESCrIPtION
CHDX 07263 *
72,000 BTU Heat Pump
208-230V/60 HZ
208-230V/60 HZ
3
3
CHDX (R) 07263 *
72,000 BTU Heat Pump
With Salt Protection - Special Order
CHDX 09663 *
96,000 BTU Heat Pump
208-230V/60 HZ
208-230V/60 HZ
3
3
CHDX (R) 09663 *
96,000 BTU Heat Pump
With Salt Protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
12
Download from Www.Somanuals.com. All Manuals Search And Download.
2- Way ECOi VRF Heat Pump
CHDXSERIES
DESCrIPtION
CHDX (R) 07263
CHDX (R) 09663
PErFOrMaNCE
COOLINg CAPACITY: BTU/H
POWER INPUT: KW
72,000
5.28
96,000
7.69
HEATINg CAPACITY: BTU/H
POWER INPUT: KW
81,000
5.79
108,000
8.6
ELECtrICaL ratINGS
VOLTAgE RATINg
COOLINg RUNNINg AMPERES
HEATINg RUNNINg AMPERES
MIN. CIRCUIT AMPACITY
MAX. CIRCUIT AMPACITY
208
15.1
16.5
26
-
-
-
230
14.1
15.5
V
A
A
208
23.0
25.4
34
-
-
-
230
21.4
23.7 b
A
A
V
A
A
A
A
40
45
COMPrESSOr
TYPE - QUANTITY
MOTOR OUTPUT
Inverter Driven Rotary Type
4.1 kw
Inverter Driven Rotary
(3 + 3.75) kw
REFRIgERATION OIL TYPE
REFRIgERATION OIL CHARgE AMOUNT
CRANKCASE HEATER
FV68S (Ether oil - PVE)
1.4 gal
25 w
FV68S (Ether oil)
1.56 gal
25 + 32 w
REFRIgERANT AMOUNT AT SHIPMENT
REFRIgERANT CONTROL
DEFROST METHOD
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%
HEAT EXCHANgER
CAPACITY CONTROL
FaN DEVICE
TYPE - QUANTITY
Propeller fan x 1
Propeller fan x 1
MOTOR OUTPUT
0.7 kw
0.7 kw
PROTECTIVE DEVICES
CFM
High pressure switch, overcurrent (CT method)
5.300
High pressure switch, overcurrent (CT method)
5.650
EXTERNAL STATIC PRESSURE
0.04 / 0.25
0.04 / 0.25
tuBING
REFRIgERANT TUBINg gAS TUBE
REFRIgERANT TUBINg LIQUID TUBE
REFRIgERANT TUBINg BALANCE TUBE
EXTERNAL AIR TEMP. OPERATION RANgE
OPERATION SOUND (HI)
3/4" (Brazing)
ø3/8" (Brazing)
ø3/8" (Flare)
Cooling: 14 to 113 (DB) / Heating: -4 to 59 (WB) °F
7/8" (Brazing)
3/8" (Brazing)
ø3/8" (Flare)
Cooling: 14 to 113 (DB) / Heating: -4 to 38 (WB) °F
54.5 (Quiet mode: 51.5) dB-A
55.0 (Quiet mode: 52.0) dB-A
uNIt DIMENSIONS
Inches (") / lbs.
Color (Munsell code)
82"/ 35"/ 35"/ 584 lbs.
Height/ Width/ Depth/ Net Weight
Silky shade (1y 8.5/0.5)
82"/ 35"/ 35"/ 683 lbs.
Height/ Width/ Depth/ Net Weight
Silky shade (1y 8.5/0.5)
(R) indicates with salt protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
13
Download from Www.Somanuals.com. All Manuals Search And Download.
W 2-Way ECOi VRF Heat Pumps combined units
WCHDXSERIES
WCHDX 14463 / WCHDX 16863 / WCHDX 19263
WCHDX 21663 / WCHDX 24063
WCHDX 26463 / WCHDX 28863
KEy FEaturES:
* Heat Pump
* Combine 3 outdoor units up to 24 tons
* Combined Series Allows Up to 40 Indoor Units (50%-130% ratio of
indoor to outdoor capacity)
*“ECO Friendly” R410A Refrigerant
* 208/230V, 3 Phase, 60Hz
* Multiple Compressors For Precise and Efficient Operation
* Operating Range (Outdoor Ambient)
-Cooling 14 FDB to 113 FDB
-Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 51.5dB(a)
* Variable Speed DC Fan Motors
SANYO’s Combined ECOi outdoor units offer
superior heating and cooling coupled with cost
effective installation. Providing a single refrigerant
pipe network means there’s only one penetration
into the building and ultimately less piping material
required, saving you time and money. A smart
conditioning solution for large capacity jobs.
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Below Indoor)
WCHDX COMBINED SERIES.
Outdoor Unit
Cooling & Heating
Power input
208/230
Control Range
SyStEM
CHDX 07263 (quantity of 2)
144,000 & 162,000 BTU/H
168,000 & 189,000 BTU/H
10.56/11.58 kW
12.97/ 14.39 kW
6 - 100%
6 - 100%
WCHDX 14463
CHDX 07263
CHDX 09663
WCHDX 16863
CHDX 09663 (quantity of 2)
192,000 & 216,000 BTU/H
216,000 & 243,000 BTU/H
240,000 & 270,000 BTU/H
15.38/ 17.2 kW
15.84/ 17.37 kW
18.25/ 20.18 kW
6 - 100%
6 - 100%
6 - 100%
WCHDX 19263
WCHDX 21663
WCHDX 24063
CHDX 07263 (quantity of 3)
CHDX 07263 (quantityof2)
CHDX 09663
WCHDX 26463
CHDX 09663 (quantityof2)
CHDX 07263
264,000 & 297,000 BTU/H
288,000 & 324,000 BTU/H
20.66/ 22.99 kW
23.07/ 25.8 kW
6 - 100%
6 - 100%
WCHDX 28863
CHDX 09663 (quantity of 3)
(R) indicates with salt protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
14
Download from Www.Somanuals.com. All Manuals Search And Download.
W 2-Way ECOi VRF Heat Pumps combined units
WCHDXSERIES
DESCrIPtION
WCHDX 14463 WCHDX 16863
WCHDX 19263
includes (2) CHDX07263
includes (1) CHDX07263 and includes (2) CHDX09663
(1) CHDX09663
PErFOrMaNCE
COOLINg CAPACITY: BTU/H 144,000
168,000
12.97
192,000
15.38
POWER INPUT: KW 10.56
HEATINg CAPACITY: BTU/H 162,000
POWER INPUT: KW 11.58
189,000
14.39
216,000
17.2
COOLING MODE NOMINaL CONDItIONS
INDOOR: °F WB/ °F DB 80/67
80/67
95
80/67
95
OUTDOOR: °F DB 95
PIPE LENgTH: FEET 25
25
25
LEVEL DIFFERENCE: FEET
0
0
0
HEatING MODE NOMINaL CONDItIONS
INDOOR: °F DB 70
OUTDOOR: °F DB/ °F WB 47/43
PIPE LENgTH: FEET 25
70
47/43
25
70
47/43
25
LEVEL DIFFERENCE: FEET
0
0
0
OPEratING raNGE
COOLINg: °F DB 14 to 113
HEATINg: °F WB -4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
COMPrESSOr
TYPE/QUANTITY 2 Inverter driven Rotary
2 Inverter driven Rotary
& 1 fixed speed scroll
6-100%
2 Inverter driven Rotary
& 2 fixed speed scroll
6-100%
CAPACITY CONTROL RANgE: % 6 - 100%
FaN
TYPE/QUANTITY 1 Propeller (ea)
FAN MOTOR OUTPUT: (KW) 0.7 kW (ea)
EXTERNAL STATIC PRESSURE .04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
POwEr SuPPLy
V/PH/HZ 208 - 230/ 3/ 60
208 - 230/ 3/ 60
208 - 230/ 3/ 60
MINIMUM CIRCUITS AMPS (MCA): (A) 52
MAX. OVERCURRENT PROTECTION (MOCP): (A) 80
60
85
68
90
wEIGHt: (LBS) 1168
1267
1366
COIL:
COIL FACE AREA:(SQ. FT.) 29.5(ea)
29.5(ea)
4(ea)
29.5(ea)
4(ea)
NUMBER OF ROWS: 4(ea)
PrOtECtION DEVICES
HIgH PRESSURE SWITCH/OVERCURRENT
Yes
(CT METHOD)
Yes
25 + 25 + 32
Yes
25 + 32 X 2
25 + 25
CRANKCASE HEATERS:(W)
EACH OUTDOOR UNIT REQUIRES A SEPARATE
ELECTRICAL FUSED DISCONNECT, SEE INDIVIDUAL
OUTDOOR REQUIREMENTS.
(R) indicates with salt protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
15
Download from Www.Somanuals.com. All Manuals Search And Download.
W 2-Way ECOi VRF Heat Pumps combined units
WCHDXSERIES
WCHDX
21663
WCHDX
24063
WCHDX
26463
WCHDX
28863
DESCrIPtION
includes (3)
CHDX07263
includes (2)
CDDX07263 and (1)
CHDX09663
includes (1)
CHDX07263 and (2)
CHDX09663
includes (3)
CHDX09663
PErFOrMaNCE
COOLINg CAPACITY: BTU/H 216,000
240,000
18.25
264,000
20.66
288,000
23.07
POWER INPUT: KW 15.84
HEATINg CAPACITY: BTU/H 243,000
POWER INPUT: KW 17.37
270,000
20.18
297,000
22.99
324,000
25.8
COOLING MODE NOMINaL CONDItIONS
INDOOR: °F WB/ °F DB 80/67
80/67
95
80/67
95
80/67
95
OUTDOOR: °F DB 95
PIPE LENgTH: FEET 25
25
25
25
LEVEL DIFFERENCE: FEET
0
0
0
0
HEatING MODE NOMINaL CONDItIONS
INDOOR: °F DB 70
OUTDOOR: °F DB/ °F WB 47/43
PIPE LENgTH: FEET 25
70
47/43
25
70
47/43
25
70
47/43
25
LEVEL DIFFERENCE: FEET
0
0
0
0
OPEratING raNGE
COOLINg: °F DB 14 to 113
HEATINg: °F WB -4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
COMPrESSOr
TYPE/QUANTITY 3 Inverter driven
Rotary
3 Inverter driven Rotary 3 Inverter driven Rotary 3 Inverter driven
& 1 fixed speed scroll
6 - 100%
& 2 fixed speed scroll
6 - 100%
Rotary
& 3 fixed speed scroll
6 - 100%
CAPACITY CONTROL RANgE: % 6 - 100%
FaN
TYPE/QUANTITY 1 Propeller (ea)
FAN MOTOR OUTPUT: (KW) 0.7 kW (ea)
EXTERNAL STATIC PRESSURE .04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller
0.7 kW
.04 / .25
POwEr SuPPLy
V/PH/HZ 208 - 230/ 3/ 60
208 - 230/ 3/ 60
208 - 230/ 3/ 60
208 - 230/ 3/ 60
MINIMUM CIRCUITS AMPS (MCA): (A) 78
MAX. OVERCURRENT PROTECTION (MOCP): (A) 120
86
125
94
130
102
135
wEIGHt: (LBS) 1752
1851
1950
2049
COIL:
COIL FACE AREA:(SQ. FT.) 29.5(ea)
29.5(ea)
4(ea)
29.5(ea)
4(ea)
29.5(ea)
4(ea)
NUMBER OF ROWS: 4(ea)
PrOtECtION DEVICES
HIgH PRESSURE SWITCH/OVERCURRENT (CT
Yes
METHOD)
Yes
Yes
Yes
3 X 25 + 32
25 + 25 + 25
25 + 25 + 25 + 32
(2 X 25 + 32) + 25
CRANKCASE HEATERS:(W)
EACH OUTDOOR UNIT REQUIRES A SEPARATE ELECTRICAL FUSED DISCONNECT,
SEE INDIVIDUAL OUTDOOR REQUIREMENTS.
(R) indicates with salt protection - Special Order
* NOtE: *460 Volt Step Down transformers (460-230) available for 6 and 8 ton condensers
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Wall-Mounted Unit
KHXSERIES
KHX 0752 / KHX 0952 / KHX 1252 / KHX 1862
KHX 1962 / KHX 2452 / ATK-SVRK56BA
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Easy Wall Mount for Any Application
* Washable Long Life Filter
SANYO’s wall-mounted units work well with any interior
design. Flexible and compact, offering individualized zoned
comfort for complete temperature control throughout the day.
Over five different air flow directions and wireless remotes
provide control in the palm of your hand.
* Electronic Expansion Valve (EEV)
for Accurate Refrigerant Control
* Light Weight, Only 31 lbs. (KHX2452 is 46 lbs.)
* Wired or Wireless Remote Control
* Easy Service
(Type: Nominal Cooling Capacity, etc)
Volt
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
N/A
PH
1
MODELS
KHX 0752
7500 BTU
9600 BTU
1
KHX 0952
KHX 1252
KHX 1862
KHX 1962
12000 BTU
1
18000 BTU
1
19000 BTU (special order)
25000 BTU
1
1
KHX 2452
N/A
ATK-SVRK56BA
External EEV (required for use with KHX 1962)
KHX 1962
DESCrIPtION
KHX 0752 KHX 0952 KHX 1252 KHX 1862
KHX 2452
needs ATK-SVRK56BA
PErFOrMaNCE
COOLINg CAPACITY 7,500 BTU/H
HEATINg CAPACITY 8,500 BTU/H
9,600 BTU/H
12,000 BTU/H 18,000 BTU/H 19,000 BTU/H
25,000 BTU/H
27,000 BTU/H
11,000 BTU/H 14,000 BTU/H 20,000 BTU/H 21,000 BTU/H
CurrENt
COOLINg 0.25/0.26 A
HEATINg 0.25/0.26 A
0.20/0.21 A
0.20/0.21 A
0.20/0.21 A
0.20/0.21 A
0.30/0.32 A
0.30/0.32 A
0.30/0.32 A
0.30/0.32 A
0.37/0.39 A
0.38/0.32 A
POwEr INPut
COOLINg 50/56 W
HEATINg 50/56 W
50/56 W
50/56 W
50/56 W
50/56 W
61/72 W
61/72 W
61/72 W
61/72 W
72/83 W
72/83 W
HEat ExCHaNGEr
FAN TYPE X QUANTITY CROSS FLOW X1 CROSS FLOW X1 CROSS FLOW X1 CROSS FLOW X1 CROSS FLOW X1
CROSS FLOW X1
565/495/350
0 IN. WC
AC
FAN AIRFLOW RATE 350/280/210
FAN EXT. STATIC PRESS (230V) 0 IN. WC
FAN MOTOR TYPE AC
350/280/210
0 IN. WC
AC
350/280/210
0 IN. WC
AC
565/495/353
0 IN. WC
AC
565/495/353
0 IN. WC
AC
FAN MOTOR OUTPUT 30 W
30 W
30 W
30 W
30 W
30 W
rEFrIGEraNt PIPE DIMENSIONS
LOW PRESSURE (FLARE) 1/4"
HIgH PRESSURE (FLARE) 1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
3/8"
5/8"
uNIt DIMENSIONS
11.5"/ 39.5"/ 8"/ 31 LBS.
13"/ 45"/ 9"/ 46 LBS.
Inches (") / lbs.
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
3/4" OD
DraINPIPE DIMENSION
SOuND LEVELS
(LOW-MED-HIgH) DB(A) @ 230V 28/32/36
28/32/36
28/32/36
35/38/42
35/38/42
35/38/42
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Ceiling Suspended Unit
THXSERIES
THX 1252 / THX 1852 / THX 2452
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Low Profile Design Fits Into Numerous Ceiling
Suspended Locations
* One Way Air Discharge with Vanes and Auto
Louvre for Efficient Air Distribution
* Washable Long Life Air Filter
* Electronic Expansion Valve (EEV) for Accurate
Refrigerant Control
SANYO’s ceiling suspended units are an ideal solution for
any medium to light commercial space perfectly.
Suited for retail stores, schools and restaurant applications,
its wide air opening provides comfortable airflow and ultra
quiet operation.
* Less Than 9 Inches Tall and Less than 36 Inches
Wide (47 Inches Wide For THX2452)
* Wired or Wireless Remote Control
* Easy Service
(Type: Nominal Cooling Capacity, etc)
Volt
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
PH
1
MODELS
THX 1252
THX 1852
THX 2452
12,000 BTU
18,000 BTU
24,000 BTU
1
1
DESCrIPtION
THX 1252
THX 1852
THX 2452
CaPaCIty
COOLINg 12,000 BTU
HEATINg 14,000 BTU
19,000 BTU
21,000 BTU
25,000 BTU
27,000 BTU
CurrENt
COOLINg 0.14/0.17 A
HEATINg 0.14/0.15 A
0.15/0.14 A
0.15/0.17 A
0.34/0.31 A
0.34/0.36 A
POwEr INPut
COOLINg 15/16 W
HEATINg 15/16 W
16/16 W
16/18 W
38/37 W
40/40 W
uNIt DIMENSIONS
8.5"/ 36"/ 27"/ 46 lbs.
8.5"/ 46.5"/ 27"/ 55 lbs.
Inches (") / lbs.
Height/ Width/ Depth/ Net Weight
Height/ Width/ Depth/ Net Weight
HEat ExCHaNGEr
FAN TYPE X QUANTITY SCIROCCO X1
SCIROCCO X1
SCIROCCO X1
FAN AIRFLOW RATE 450/390/320 - CFM - (H/M/L)
FAN EXT. STATIC PRESS (230V) 0 - In.WC
450/390/320 - CFM - (H/M/L)
0 - In.WC
DC
653/530/495 - CFM - (H/M/L)
0 - In.WC
DC
FAN MOTOR TYPE DC
FAN MOTOR OUTPUT 60 - W
60 - W
60 - W
rEFrIGEraNt PIPE DIMENSIONS
LOW PRESSURE (FLARE) 1/4"
HIgH PRESSURE (FLARE) 1/2"
1/4"
1/2"
3/8"
5/8"
DraINPIPE DIMENSION 1" OD
1" OD
1" OD
SOuND LEVELS
(LOW-MED-HIgH) 30/32/35 - DB(A) @ 230V
30/33/36 - DB(A) @ 230V
33/36/38 - DB(A) @ 230V
18
Download from Www.Somanuals.com. All Manuals Search And Download.
ONE WAY Ceiling Cassette, with condensate Pump
AHXSERIES
07 AHX 52 / 09 AHX 52/ 12 AHX 52
KEy FEaturES:
*“ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* One-Way Air Throw – Perfect for Small Spaces
* Washable Long Life Air Filter
* Built-In Drain Pump – 24 Inch Lift Possible Above
Outlet Drain Connection
* Electronic Expansion Valve (EEV) for Accurate
Refrigerant Control
*Only 13 Inches Tall (Not Including Decorative Panel),
30 Inches Wide and 25 Inches Deep
* Wired or Wireless Remote Control
* Optional Fresh Air Intake
SANYO’s semi-concealed ceiling
units are flexible and space-
saving. A perfect conditioning
solution for small spaces. Barely
visible, the unit blends with any
interior design. Powerful enough
to cool and comfort those inside.
* Easy Service
Components (Type: Nominal Cooling Capacity, etc)
Volt
PH
SyStEM/MODEL
System
7500 BTU 1-Way Ceiling cassette (includes grille)
208-230V/60 HZ
208-230V/60 HZ
1
1
07AHX 52
AHX 0752
PNR-AH1252
System
cassette
grille
9000 BTU 1-Way Ceiling cassette (includes grille)
208-230V/60 HZ
208-230V/60 HZ
1
1
09 AHX 52
AHX 0952
PNR-AH1252
System
cassette
grille
12000 BTU 1-Way Ceiling cassette (includes grille)
208-230V/60 HZ
208-230V/60 HZ
1
1
12 AHX 52
AHX 1252
PNR-AH1252
cassette
grille
DESCrIPtION
07AHX 52 09 AHX 52 12 AHX 52
PErFOrMaNCE
COOLINg CAPACITY 7,500 BTU/H
HEATINg CAPACITY 8,500 BTU/H
9,600 BTU/H
11,000 BTU/H
12,000 BTU/H
14,000 BTU/H
CurrENt
COOLINg 0.29/0.28 A
HEATINg 0.28/0.26 A
0.29/0.28 A
0.28/0.26 A
0.32/0.31 A
0.34/0.32 A
POwEr INPut
COOLINg 48/50 W
HEATINg 44/46 W
48/50 W
44/46 W
52/55 W
50/52 W
HEat ExCHaNGEr
FAN TYPE X QUANTITY SCIRROCO X1
FAN AIRFLOW RATE 282/247/212
FAN EXT. STATIC PRESS (230V) 0 IN. WC
FAN MOTOR TYPE DC
SCIRROCO X1
282/247/212
0 IN. WC
DC
SCIRROCO X1
320/280/250
IN. WC
DC
FAN MOTOR OUTPUT 60 W
60 W
60 W
rEFrIGEraNt PIPE DIMENSIONS
LOW PRESSURE (FLARE) 1/4"
HIgH PRESSURE (FLARE) 1/2"
1/4"
1/2"
1/4"
1/2"
uNIt DIMENSIONS
13"/ 30"/ 24.5"/ 43 LBS.
Inches (") / lbs.
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
DraINPIPE DIMENSION
1 1/4" OD
SOuND LEVELS
(LOW-MED-HIgH) DB(A) @ 230V
29/31/33
19
Download from Www.Somanuals.com. All Manuals Search And Download.
XMHXSERIES
4-WayCeilingCassette24"x24",withCondensatePump
12 XMHX 52 / 18 XMHX 52
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Four Way Air Throw
* Washable Long Life Air Filter
* Built-In Drain Pump – 25 Inch Lift
Possible Above Outlet Drain Connection
* Electronic Expansion Valve (EEV)
for Accurate Refrigerant Control
* A Low Profile Unit Perfectly Suited
for Compact Ceiling Voids (as little as 12-14 inches)
* Wired or Wireless Remote Control
* Easy Service
SANYO’s 4-Way semi-concealed ceiling
units are flexible, efficient and space-saving.
Now available to fit within standard
24"x24"ceiling grids.
* Optional Fresh Air Intake
Components (Type: Nominal Cooling Capacity, etc)
Volt
PH
SyStEM/MODEL
System
12000 BTU 4-Way Ceiling cassette 24" x 24" (includes grille) 208-230V/1ø/60 HZ
1
1
XMHX 1252
PNR-XMH1252
System
cassette
grille
208-230V/1ø/60 HZ
12 XMHX 52
18000 BTU 4-way Ceiling cassette 24" x 24" (includes grille) 208-230V/1ø/60 HZ
1
1
XMHX 1852
PNR-XMH1852
cassette
grille
208-230V/1ø/60 HZ
18 XMHX 52
DESCrIPtION
12 XMHX 52 18 XMHX 52
PErFOrMaNCE
COOLINg CAPACITY 12,000 BTU/H
HEATINg CAPACITY 14,000 BTU/H
19,000 BTU/H
21,000 BTU/H
CurrENt
COOLINg 0.22/0.20 A
HEATINg 0.19/0.17 A
0.30/0.32 A
0.27/0.30 A
POwEr INPut
COOLINg 38/43 W
HEATINg 30/35 W
52/56 W
48/47 W
HEat ExCHaNGEr
FAN TYPE X QUANTITY TURBO X1
FAN AIRFLOW RATE 320/280/250
FAN MOTOR TYPE DC
TURBO X1
440/370/320
DC
FAN MOTOR OUTPUT 20 W
20 W
rEFrIGEraNt PIPE DIMENSIONS
LOW PRESSURE (FLARE) 1/4"
HIgH PRESSURE (FLARE) 1/2"
1/4"
1/2"
uNIt DIMENSIONS
12.5"/ 24.75"/ 24.75"/ 41 LBS.
Inches (") / lbs.
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
4-WAY AIR DISCHARgE
24" X 24" SYSTEM
(INCLUDES gRILLE)
DraINPIPE DIMENSION
1 1/4" OD
SOuND LEVELS
(LOW-MED-HIgH) DB(A) @ 230V 27/29/31
33/37/41
20
Download from Www.Somanuals.com. All Manuals Search And Download.
4-Way Ceiling Cassette 35" x 35", with Condensate Pump
XHXSERIES
24 XHX 52 / 36 XHX 52
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Four Way Air Throw
* Washable Long Life Air Filter
* Built-In Drain Pump – 25 Inch Lift
Possible Above Outlet Drain Connection
* Electronic Expansion Valve (EEV)
for Accurate Refrigerant Control
SANYO’s 4-Way semi-concealed ceiling
units are flexible, efficient and
space-saving. Two sides can be adjusted
simply to accommodate corner airflow.
* A Low Profile Unit Perfectly Suited
for Compact Ceiling Voids (as little as 12-14 inches)
* Wired or Wireless Remote Control
* Easy Service
* Branch Duct Available
* Optional Fresh Air Intake
Components (Type: Nominal Cooling Capacity, etc)
Volt
PH
SyStEM/MODEL
System
25000 BTU 4-Way Ceiling cassette 35" x 35" (includes
grille)
208-230V/60 HZ
1
24 XHX 52
XMX 2452
PNR-XMH1252
System
cassette
grille
208-230V/60 HZ
1
36000 BTU 4-Way Ceiling cassette 35" x 35" (includes grille) 208-230V/60 HZ
1
1
XMX 3652
PNR-XMH1852
cassette
grille
208-230V/60 HZ
36 XHX 52
DESCrIPtION
24 XMHX 52
36 XMHX 52
PErFOrMaNCE
COOLINg CAPACITY 25,000 BTU/H
HEATINg CAPACITY 27,000 BTU/H
36,000 BTU/H
39,000 BTU/H
CurrENt
COOLINg 0.29/0.26 A
HEATINg 0.30/0.31 A
0.51/0.46 A
0.54/0.49 A
POwEr INPut
COOLINg 38/40 W
HEATINg 33/33 W
74/79 W
76/76 W
HEat ExCHaNGEr
FAN TYPE X QUANTITY TURBO X1
FAN AIRFLOW RATE 705/565/495
FAN MOTOR TYPE DC
TURBO X1
990/810/740
DC
FAN MOTOR OUTPUT 50 W
90 W
rEFrIGEraNt PIPE DIMENSIONS
LOW PRESSURE (FLARE) 3/8"
HIgH PRESSURE (FLARE) 5/8"
3/8"
5/8"
12" / 35" / 35" / 58 LBS.
HEIgHT/WIDTH/DEPTH/NET WEIgHT
uNIt DIMENSIONS 12"/ 35"/ 35"/ 58 LBS.
TWO SIDES CAN BE
ADjUSTED SIMPLY TO
ACCOMMODATE
Inches (") / lbs. HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
DraINPIPE DIMENSION
1 1/4 "OD
SOuND LEVELS
(LOW-MED-HIgH) DB(A) @ 230V 28/31/34
33/36/39
CORNER AIRFLOW.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
UMHXSERIES
Concealed Ducted - Low Profile, Low Static, with Condensate Pump
UMHX 0762 / UMHX 0962 / UMHX 1262
UMHX 1562 / UMHX 1862
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Electronic Expansion Valve (EEV) for Accurate
Refrigerant Control
* Adjustable External Static Pressure
* Built-In Drain Pump – 20 Inch Lift
* Wired or Wireless Remote Control
* Bottom or Rear Return Air
* Easy Service
* 8 inches high"
* Low Profile fits into tight ceiling spaces
* Optional Fresh Air Intake
8 inches high
Low Profile fits into tight ceiling spaces.
* Washable Long Life Filter
(Type: Nominal Cooling Capacity, etc)
Volt
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
PH
1
MODELS
UMHX 0762
7500 BTU
ESP = 0.04 / 0.12
ESP = 0.06 / 0.12
ESP = 0.06 / 0.16
ESP = 0.06 / 0.16
ESP = 0.16 / 0.16
9600 BTU
1
UMHX 0962
UMHX 1262
UMHX 1562
UMHX 1862
12000 BTU
1
15000 BTU
1
19000 BTU
1
DESCrIPtION
UMHX 0762 UMHX 0962 UMHX 1262 UMHX 1562 UMHX 1862
PErFOrMaNCE
COOLINg CAPACITY 7,500 BTU/H
HEATINg CAPACITY 8,500 BTU/H
9,600 BTU/H
11,000 BTU/H
12,000 BTU/H
14,000 BTU/H
15,000 BTU/H
17,000 BTU/H
19,000 BTU/H
21,000 BTU/H
CurrENt
COOLINg 0.22/0.21 A
HEATINg 0.23/0.22 A
0.261/0.25 A
0.28/0.28 A
0.28/0.26 A
0.30/0.37 A
0.34/0.33 A
0.36/0.35 A
0.47/0.43 A
0.51/0.47 A
POwEr INPut
COOLINg 32/30 W
HEATINg 32/30 W
35/37 W
37/40 W
37/39 W
39/40 W
44/46 W
47/49 W
59/61 W
63/64 W
HEat ExCHaNGEr
FAN TYPE CENTRIFUgAL
FAN AIRFLOW RATE 212 / 247 / 283
FAN EXT. STATIC PRESS (230V) 0.04 / 0.12 IN. WC
FAN MOTOR TYPE AC
CENTRIFUgAL
230 / 265 / 300
0.06 / 0.12 IN. WC
AC
CENTRIFUgAL
247 / 283 / 318
0.06 / 0.16 IN. WC
AC
CENTRIFUgAL
283 / 336 / 371
0.06 / 0.16 IN. WC
AC
CENTRIFUgAL
0353 / 406 / 442
0.06 / 0.16 IN. WC
AC
FAN MOTOR OUTPUT 50 W
50 W
50 W
50 W
50 W
rEFrIGEraNt PIPE DIMENSIONS
LOW PRESSURE (FLARE) 1/4"
HIgH PRESSURE (FLARE) 1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
7 7/8", 29 17/32", 25 13/64", 42 LBS
uNIt DIMENSIONS
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
Inches (") / lbs.
DraINPIPE DIMENSION
1 1/4" OD
SOuND LEVELS
(LOW-MED-HIgH) DB(A) @ 230V 25/27/28
27/29/30
28 / 30 / 32
30 / 32 / 34
31 / 33 / 35
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Concealed Ducted - Medium Static
UHXSERIES
UHX 0762 / UHX 0962 / UHX 1262
UHX 1562 / UHX 1862 / UHX 2462
UHX 3662 / UHX 4862 / UHX 5462
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Includes 8" round duct connections (two 8" duct collars for 7-15,000 BTU units three
8" duct collars for 18-24,000 BTU unit and four 8" duct collars for 36-54,000 BTUs units)
can be removed for plenum ducting.
* Electronic Expansion Valve (EEV) for Accurate
Refrigerant Control
* Adjustable External Static Pressure
* Built-In Drain Pump – 20 Inch Lift
* Wired or Wireless Remote Control
* Bottom or Rear Return Air
SANYO’s concealed ceiling units are compact and space
saving. Advanced zoning capabilities. Efficient design.
A perfect conditioning solution for shorter duct runs.
* Easy Service
* Optional Fresh Air Intake
(Type: Nominal Cooling Capacity, etc)
Volt
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
208-230V/60 HZ
PH
1
MODELS
UHX 0762
UHX 0962
UHX 1262
UHX 1562
UHX 1862
UHX 2462
UHX 3662
UHX 4862
UHX 5462
7500 BTU
9600 BTU
0.28 / 0.40 ESP
0.28 / 0.40 ESP
1
12000 BTU 0.28 / 0.40 ESP
15000 BTU 0.28 / 0.44 ESP
19000 BTU 0.32 / 0.48 ESP
25000 BTU 0.32 / 0.48 ESP
36000 BTU 0.32 / 0.49 ESP
48000 BTU 0.31 / 0.45 ESP
54600 BTU 0.31 / 0.45 ESP
1
1
1
1
1
1
1
UHX 0762 UHX 0962 UHX 1262 UHX 1562 UHX 1862 UHX 2462 UHX 3662
UHX 4862
UHX 5462
DESCrIPtION
PErFOrMaNCE
COOLINg CAPACITY 7,500 BTU/H
HEATINg CAPACITY 8,500 BTU/H
9,600 BTU/H 12,000 BTU/H
11,000 BTU/H 14,000 BTU/H
15,000 BTU/H 19,000 BTU/H 25,000 BTU/H 36,000 BTU/H
17,000 BTU/H 21,000 BTU/H 27,000 BTU/H 39,000 BTU/H
47,800 BTU/H
54,600 BTU/H
54,600 BTU/H
61,400 BTU/H
CurrENt
COOLINg 0.45/0.49 A
HEATINg 0.42/0.46 A
0.45/0.49 A
0.42/0.46 A
0.52/0.55 A
0.49/0.54 A
0.52/0.55 A
0.49/0.54 A
0.90/0.96 A
0.89/0.95 A
0.90/0.96 A
0.89/0.95 A
1.15/1.25 A
1.10/1.18 A
1.25/1.34 A
1.13/120 A
1.25/1.34 A
1.13/120 A
POwEr INPut
COOLINg 92/112 W
HEATINg 87/104 W
92/112 W
87/104 W
107/125 W
100/122 W
107/125 W
100/122 W
183/219 W
182/214 W
183/219 W
182/214 W
235/282 W
224/267 W
254/301 W
230/271 W
254/301 W
230/271 W
HEat ExCHaNGEr
FAN TYPE CENTRIFUgAL X1 CENTRIFUgAL X1 CENTRIFUgAL X1
CENTRIFUgAL X1 CENTRIFUgAL X1
CENTRIFUgAL X1
671/565/459
0.48 IN. WC
AC
CENTRIFUgAL X1
1060/919/742
0.49 IN. WC
AC
CENTRIFUgAL X1
1116/1060/883
0.45 IN. WC
AC
CENTRIFUgAL X1
1166/1060/883
0.45 IN. WC
AC
HI/MED/LOW FAN AIRFLOW RATE 353/300/247
FAN EXT. STATIC PRESS (230V) 0.40 IN. WC
FAN MOTOR TYPE AC
353/300/247
0.40 IN. WC
AC
424/371/318
0.40 IN. WC
AC
424/371/318
0.44 IN. WC
AC
671/565/459
0.48 IN. WC
AC
FAN MOTOR OUTPUT 50 W
50 W
70 W
70 W
100 W
100 W
140 W
140 W
140 W
rEFrIGEraNt PIPE DIMENSIONS
LOW PRESSURE (FLARE) 1/4"
HIgH PRESSURE (FLARE) 1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
3/8"
5/8"
3/8"
5/8"
3/8"
5/8"
3/8"
5/8"
uNIt DIMENSIONS
12.5"/ 27.5"/ 25"/ 53 LBS.
12.5"/ 58.5"/ 25"/104 LBS.
12.5"/ 39.5"/ 25"/ 71LBS.
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
12.5"/58.5"/ 25"/ 104LBS.
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
12.5"/ 58.5"/ 25"/ 104 LBS.
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
HEIgHT/ WIDTH/ DEPTH/ NET WEIgHT
Inches (") / lbs.
DraINPIPE DIMENSION
1 1/4" OD
SOuND LEVELS
(LOW-MED-HIgH) DB(A) @
24/28/31
230V
24/28/31
24/28/31
26/30/33
27/32/36
27/32/36
31/33/38
33/37/40
33/37/40
23
Download from Www.Somanuals.com. All Manuals Search And Download.
DHXSERIES
Concealed Ducted - Medium-High Static
DHX 3652 / DHX 4852
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Electronic Expansion Valve (EEV) for
Accurate Refrigerant Control
* Perfect for Long Duct Runs
* Wired or Wireless Remote Control
* Easy Service
* Built-in float safety
SANYO’s concealed ceiling units are flexible and space saving,
helping maximize floor and wall space. Advanced zoning
capabilities condition large areas simply and efficiently.
Completely concealed, they offer simple installation.
A PERFECT APPLICATION FOR
LONgER DUCT RUN INSTALLATIONS.
(Type: Nominal Cooling Capacity, etc)
Volt
208-230V/60 HZ
208-230V/60 HZ
PH
1
MODELS
DHX 3652
DHX 4852
36,000 BTU
48,000 BTU
ESP = 0.70"
ESP = 0.67"
1
DESCrIPtION
DHX 3652
DHX 4852
CaPaCIty
COOLINg 36,000 BTU
HEATINg 39,000 BTU
47,800 BTU
54,600 BTU
CurrENt
COOLINg 2.84/2.89 A
HEATINg 2.74/2.80 A
3.24/3.19 A
3.17/3.42 A
POwEr INPut
COOLINg 548/620 W
HEATINg 528/602 W
644/695 W
627/756 W
uNIt DIMENSIONS 16.5"/ 42"/ 24.5"/ 110 lbs.
18"/ 42"/ 24.5"/ 119 lbs.
Inches (") / lbs. Height/ Width/ Depth/ Net Weight
Height/ Width/ Depth/ Net Weight
HEat ExCHaNGEr
FAN TYPE X QUANTITY CENTRIFUgAL X1
FAN AIRFLOW RATE 1,060/988/883 - CFM - (H/M/L)
FAN EXT. STATIC PRESS (230V) 0.70 - In.WC
FAN MOTOR TYPE AC
CENTRIFUgAL X1
1,272/1,237/1,160 - CFM - (H/M/L)
0.67 - In.WC
AC
FAN MOTOR OUTPUT 200 - W
400 - W
rEFrIGEraNt PIPE DIMENSIONS
LOW PRESSURE (FLARE) 3/8"
HIgH PRESSURE (FLARE) 5/8"
3/8"
5/8"
DraINPIPE DIMENSION 1 1/4" OD
1 1/4" OD
SOuND LEVELS
(LOW-MED-HIgH) 42/44/45 - DB(A) @ 230V
44/46/47 - DB(A) @ 230V
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Floor Mounted
FHX/FMHXSERIES
FHX 0762 / FHX 0962 / FHX 1262
FHX 1562 / FHX 1862 / FHX 2462
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Electronic Expansion Valve (EEV) for
Accurate Refrigerant Control
* Wired or Wireless Remote Control
* Easy Service
FLOOR MOUNTED
* Washable Long Life filter
WITH DECORATIVE PANEL
FMHX 0762 / FMHX 0962 / FMHX 1262
FMHX 1562 / FMHX 1862 / FMHX 2462
KEy FEaturES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Electronic Expansion Valve (EEV) for
Accurate Refrigerant Control
* Wired or Wireless Remote Control
* Easy Service
FLOOR MOUNTED
WITH OUT DECORATIVE PANEL
* Washable Long Life filter
FHX/FMHX
FHX/FMHX
FHX/FMHX
FHX/FMHX
FHX/FMHX
FHX/FMHX
DESCrIPtION
0762
0962
1262
1562
1862
2462
CaPaCIty
COOLINg
HEATINg
7,500 BTU
8,500 BTU
9.600 BTU
11,000 BTU
12,000 BTU
14,000 BTU
15,000 BTU
17,000 BTU
19,000 BTU
21,000, BTU
24,000 BTU
27,000 BTU
CurrENt
COOLINg
HEATINg
.22/.24 A
.22/.23 A
.22/.24 A
.22/.23 A
.42/.44
.40/.42
.58/.60
.53/.55
.58/.60
.53/.55
.61/.63
.56/.58
POwEr INPut
COOLINg
45/54 W
43-50 W
45/54 W
43-50 W
86/101
83/96
116/134
106/122
116/134
106/122
119/138
109/125
HEATINg
FHx uNIt DIMENSIONS
24.25"/42"/9"/64 lbs.
Height/ Width/ Depth/ Net Weight
24.2"/42"/9"/64 lbs.
Height/ Width/ Depth/ Net Weight
24.2"/42"/9"/64 lbs.
Height/ Width/ Depth/ Net Weight
24.0"/54.5"/9"/86 lbs.
Height/ Width/ Depth/ Net Weight
24.0"/54.5"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
24.0"/54.5"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
Inches (") / lbs.
FMHx uNIt DIMENSIONS
24.25"/35.5"/9"/46 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/35.5"/9"/46 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/35.5"/9"/46 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/48"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/48"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/48"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
Inches (") / lbs.
HEat ExCHaNGEr
FAN TYPE X QUANTITY
FAN AIRFLOW RATE
FAN MOTOR OUTPUT
Centrifugal
247/212/177
10 W
Centrifugal
247/212/177
10 W
Centrifugal
318/247/212
20 W
Centrifugal
424/318/283
20 W
Centrifugal
530/459/389
30 W
Centrifugal
601/495/424
60 W
rEFrIGEraNt
PIPE DIMENSIONS
LOW PRESSURE (FLARE) 1/4"
HIgH PRESSURE (FLARE) 1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
3/8"
5/8"
DraINPIPE DIMENSION 1 1/4" OD
1 1/4" OD
1 1/4" OD
1 1/4" OD
1 1/4" OD
1 1/4" OD
SOuND LEVELS
(LOW-MED-HIgH)
28/30/33
28/30/33
29/35/39
31/35/38
31/36/39
35/38/41
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Simple System Control Network S-Net
CONTROl SYSTEMS
RCS-TM80Bg / RCS-BH80AAB.WL / RCS-SH80AAB.WL
RCS-TRP80AAB.WL / RCS-XM18AAB.WL
SANYO’s system control network is the heart and soul
of the ECOi™ unit, enabling it to live with the living
inside. With a simple two-wire loop installation,
we put control in your hands, literally. No outside
specialists required, it’s an all-in-one solution for
you, and a way to further build profits by keeping
installation in-house. The logic resides in the ECOi
system and the control is the gateway.
RCS-SH1AAB.WL / RCS-KR1Eg / SHA-KC64Ug
SHA-TM64AgB / SHA-KT256EA / SHA-KA128AAB
ART-K45AgB / SHA-LN16UBA / BMS-CTRL1
TECS-5000KA / TECS-5000AA / TECS-5000gA
TECS-5000BA / TECS-5000WA
NO OUTSIDE SPECIALISTS REQUIRED,
IT’S AN ALL-IN-ONE SOLUTION FOR YOU.
DESCRIPTION
NOTES
Part NuMBEr
WIRED REMOTE CONTROLLER — 7- day setback, mode, temp, service, etc.
WIRELESS REMOTE CONTROLLER — For use with UHX, UMHX, DHX, FHX and FMHX models
RCS-TM80Bg
RCS-BH80AAB.WL
RCS-SH80AAB.WL
RCS-TRP80AAB.WL
RCS-XM18AAB.WL
RCS-SH1AAB
WIRELESS REMOTE CONTROLLER — For use with XHX models
WIRELESS REMOTE CONTROLLER — For use with AHX and THX models
WIRELESS REMOTE CONTROLLER — For use with XMHX models
WIRELESS REMOTE CONTROLLER — For use with KHX models
SIMPLE REMOTE CONTROLLER (wired) — on/off, Mode, Temp, Fan Speed, Flap, Service Function
SYSTEM CONTROLLER — Set individual indoor unit temps for up to 4 zones, 16 indoor units max per zone
SCHEDULE TIMER — Thermal On/Off at program times only, no set back temperature
INTELLIgENT CONTROLLER ( Web Enabled ) — Controls Max of 256 indoor units with SHA-KA128AAB
COMMUNICATIONS ADAPTOR — Used with INTELLIgENT CONTROLLER and BMS interface
REMOTE SENSOR
RCS-KR1Eg
SHA-KC64Ug
SHA-TM64AgB
SHA-KT256EA
SHA-KA128AAB
ART-K45AgB
LONWORKS INTERFACE — Maximum of 16 indoor units
SHA-LN16UAB
BMS-CTRL1
BMS INTERFACE — BACnet, LONworks, N2 or MODBUS (also requires SHA-KA128AAB)
STAIMS — Base Software Package
TECS-5000KA
TECS-5000AA
TECS-5000gA
TECS-5000BA
TECS-5000WA
STAIMS — Electrical Power Distribution Proportioning Software (also requires TECS-5000KA)
STAIMS — Layout graphic Display Software (also requires TECS-5000KA)
STAIMS — BACnet Interface Software (also requires TECS-5000KA)
STAIMS — Web Enabling Software (also requires TECS-5000KA)
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Simple System Control Network
CONTROl SYSTEMS
WIRElESS REMOTES
CONTROL IN THE PALM
OF YOUR HAND.
They enable the user to truly take control of the entire
system, from mode, temperature, airflow, and system
diagnosis, all through an easy-to-read liquid crystal
display. Control at your fingertips.
RCS-SH80AAB.WL
RCS-SH1AAB
For Use With XHX Indoor Units
For Use With KHX Indoor Units
KEy FEaturES:
* Thin and Easy To Read
* Simple To Install and Use
* Can Be Adapted for Use On All ECOi Indoor Units
* Fan Speed Control
* Timer Mode Start/Stop
* Timer Mode On/Off
* Operating Mode
* Inspection/Test Indication
* Remote Can Be Configured To Sense Temperature
RCS-BH80AAB.WL
For Use With UHX, UMHX,
DHX, FHX and FMHX Indoor Units
RCS-TRP80AAB.WL
For Use With AHX and THX Indoor Units
SANYO’s wireless remotes control more than comfort.
WIRED REMOTES
SIMPLE TO INSTALL
Simple remotes offer control where minimal functionality is best suited for those
inside. SANYO’s Standard Remote with 7 Day Timer is perfectly suited
for those requiring more programmed management over multiple zones.
By offering immediate diagnostics and up to six-daily set temperature schedules,
it’s a perfectly controlled solution offering intuitive simplicity.
KEy FEaturES (StaNDarD rEMOtE/7 Day tIMEr):
* Thin and Easy To Read
* Simple To Install and Use
* Can Be Adapted for Use On All ECOi Indoor Units
* Fan Speed Control
* Airflow Direction
* Operating Mode (Heating/Cooling/Auto/Dry/Fan)
* Vacation Mode for Continued Energy Efficiencies
* Full 7 Day Set-Back Functionality, With Up To 6 Time
Periods/Day
* Full System Diagnostic Capability
(Diagnostic History Provides Immediate View of System
Past and Present.)
KEy FEaturES: (SIMPLE rEMOtE)
* Thin and Easy To Read
* Simple To Install and Use
* Can Be Adapted for Use On All ECOi Indoor Units
* Mode
* Operating Mode (Heating/Cooling/Auto/Dry/Fan)
* Vacation Mode for Continued Energy Efficiencies
* Fan Speed Control
RCS-TM80Bg
RCS-kR1Eg
Standard Remote/7 Day Timer
For Use With All Indoor Units
Simple Remote Controller
* Set Temperature
* On/Off
* Airflow Direction
SANYO’s wired remote controls offer multiple conditioning solutions
to meet the needs of any project.
* Perfectly Suited for Applications Where Simpler
Functionality is Required (ie: Hotel Rooms, Nursing
Homes, Offices)
27
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTROl SYSTEMS
Simple System Control Network
MUlTIPlE ZONE
CONTROllERS
THE HEART AND SOUL
OF CONDITIONINg.
KEy FEaturES (SyStEM CONtrOL):
* Controls Up To 64 Units Into
4 Individualized Zones
* Alarm and Operational Signal Output
* Single Access Points for All Connected
Wired Remotes
SHA-kC64Ug
System Controller
Controls Up To 64 Units Into 4 Individualized Zones
SANYO’s system and intelligent controls are the central nervous system
to the conditioning system. The gateway to all data, temperature and
system diagnostics.
CONTROLS UP TO
256 INDOOR UNITS
KEy FEaturES (INtELLIGENt CONtrOL):
* 6.5 Inch Touch Screen Panel
* Controls up to 256 Indoor units with added
Communication Adapter (128 indoors without)
* New Control Wiring System (S Net) Connects Up
To 64 Units To a Single Control Line
* Offers a Maximum Installation of Two System
Controls (One Main, One Sub)
* Provides Individual Tenant Billing data for
3 systems addition systems are done by adding
Communication Adapters. Requires watt hour meters
* Provides Individual Tenant Billing Data Through
Calculations Based on a Per-Tenant Basis
* Individual Zone Override Feature
SHA-KT256BA
Intelligent Controller
(High/Low Setting)
* Web Accessible/Real Time Diagnostics
Through Individual IP Address
* Diagnostic History of System Past and Present
Web Accessible/Real Time Diagnostics Through Individual IP Address
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Building Management Integration
CONTROl SYSTEMS
lONWORKS INTERFACE
SINgLE POINT OF CONTROL
KEy FEaturES:
* Communicate With LonWorks Compatible Systems
* Start/Stop
* Controls Up To 16 groups (Maximum 64 Indoor Units)
* For 17 or more groups of indoor units connect additional
interface units.
* Temperature Setting, Fan Speed, etc.
* Schedule Time Setting
SHA-LN16UAB
LonWorks Interface
SANYO’s LonWorks interface integrates into many compatible
Building Management Systems. Single point of control. Access
to all of the ECOi™ conditioning mechanics.
* Alarm Notification
BMS CONTROllER
BMS-CTRL1
KEy FEaturES:
* Able to provide BMS integration to a variety of BMS
protocols including BACnet, Modbus LonWorks and N2
* Communicates with up to 90 indoor units and 10 out
door units (note; N2 can communicate with 40 indoor
and 10 outdoor units)
BMS-CTRL1
BacNet Interface
SANYO’s BMS Controller sets a new standard for multiple
equipment protocol conversion.
* Provides control of operating mode, fan, set temperature
* Provides status of operating modes and alarm status
NETWORK DIAgRAM
Building automation
Communication
Adaptor
System
BACnet
LonWorks
OEMPrtl Pro
(Up to 10 outdoor units & 90
indoor units)
Modbus
N2
Outdoor unit
Remote
Group control
Controller
Remote
Weekly
Timer
Group control
Controller
29
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
Simple System Control Network
DESCRIPTION
2-Way Distribution Kits (cut to fit)
Part NuMBEr
APR-P160UK
DISTRIBUTION jOINT KIT CUT TO FIT
DISTRIBUTION jOINT KIT CUT TO FIT
DISTRIBUTION jOINT KIT CUT TO FIT
DISTRIBUTION jOINT KIT CUT TO FIT
DISTRIBUTION jOINT KIT CUT TO FIT
Used with 2 Pipe indoor Unit Piping - Up to 76,400 BTUs
Used with 2 Pipe indoor Unit Piping - 76,500 to 232,000 BTUs
Used with 2 Pipe indoor Unit Piping - 232,200 to 460,700 BTUs
Used to Connect Multiple 2 Pipe Outdoor Units - Up to 232,000 BTUs
Used to Connect Multiple 2 Pipe Outdoor Units - 232,200 to 460,700 BTUs
APR-P680UK
APR-P1350UK
APR-CHP680UK
APR-CHP1350UK
3-Way Distribution Kits (cut to fit)
DISTRIBUTION jOINT KIT CUT TO FIT
DISTRIBUTION jOINT KIT CUT TO FIT
DISTRIBUTION jOINT KIT CUT TO FIT
DISTRIBUTION jOINT KIT CUT TO FIT
Used with 3 Pipe Indoor Unit Piping - Up to 76,400 BTUs
APR-RZP224UK
APR-RZP680UK
Used with 3 Pipe Indoor Unit Piping - 76,500 to 232,000 BTUs
Used with 3 Pipe Indoor Unit Piping - 232,200 to 460,700 BTUs
Used to Connect Multiple 3 Pipe Outdoor Units - Up to 307,100 BTUs
APR-RZP1350UK
APR-CHRZP900UK
3-Way SolenoidValve Kits
SOLENOID VALVE KIT
SOLENOID VALVE KIT
Total Indoor Capacity of Less than 19,000 BTUs (for 3 Pipe System)
ATK-RZP56BAWB
Total Indoor Capacity of 19,100 to 54,600 BTUs (for 3 Pipe System)
BallValves
ATK-RZP160BAWB
1/4" Ball Valve
3/8" Ball Valve
1/2" Ball Valve
5/8" Ball Valve
3/4" Ball Valve
7/8" Ball Valve
1-1/8" Ball Valve
1-3/8" Ball Valve
1-5/8" Ball Valve
With Access Port Fitting
BVT 14
BVT 38
BVT 12
BVT 58
BVT 34
BVT 78
BVT 118
BVT 138
BVT 158
With Access Port Fitting
With Access Port Fitting
With Access Port Fitting
With Access Port Fitting
With Access Port Fitting
With Access Port Fitting
With Access Port Fitting
With Access Port Fitting
Mini Condensate Pumps
115 VOLT MINI AQUA ASPEN CONDENSATE PUMP Max 26' Lift, 3.7 gPH @ 0 Lift, 0.8 gPH @ 26'
ASP-MA115
ASP-MA230
ASP-ML115
ASP-ML230
ASP-MO115
ASP-MO230
230 VOLT MINI AQUA ASPEN CONDENSATE PUMP Max 26' Lift, 3.7 gPH @ 0 Lift, 0.8 gPH @ 26'
115 VOLT MINI LIME ASPEN CONDENSATE PUMP
230 VOLT MINI LIME ASPEN CONDENSATE PUMP
115 VOLT MINI ORANgE ASPEN PUMP
Max 26' Lift, 3.7 gPH @ 0 Lift, 0.8 gPH @ 26'
Max 26' Lift, 3.7 gPH @ 0 Lift, 0.8 gPH @ 26'
Max 26' Lift, 3.7 gPH @ 0 Lift, 0.8 gPH @ 26'
Max 26' Lift, 3.7 gPH @ 0 Lift, 0.8 gPH @ 26'
230 VOLT MINI ORANgE ASPEN PUMP
FRESH AIR CHAMBER For Use With XHX2452 and XHX3652 Indoor Units Only (Requires CMB-gS140AA)
CMB-FS140AA
460Transformers
460V TO 230V, 11 KVA TRANSFORMER
For Use With CHDX07263, or CHDZ07263, One Per Outdoor Unit
ACC-195674
460V TO 230V, 14 KVA TRANSFORMER
For Use With CHDX09663, or CHDZ09663, One Per Outdoor Unit
ACC-195679
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Simple System Control Network
SERVICES
Pac Checker Service & diagnostics tool for all ECOi and SANYO Splits greater than 26,000 BTUs
ACC-CR-USB
DESCRIPTION
Part NuMBEr
ECO-SC-4
ECOi COMMISSIONINg (Per normal business day, up to 24 tons)
COMMISSIONINg OF INTELLIgENT CONTROLLER (Base fee for each Intelligent Controller)
COMMISSIONINg OF INTELLIgENT CONTROLLER (Indoor Units)
COMMISSIONINg OF LONWORKS INTERFACE MODULE (Base fee)
IC-SC-1
IC-SC-INDOOR
lW-SC-1
COMMISSIONINg OF LONWORKS INTERFACE (Indoor Units fee)
lW-SC-INDOOR
PP-SC-1
COMMISSIONINg OF INTELLIgENT BACnet INTERFACE (Base fee for each BMS-CTRL 1)
COMMISSIONINg OF INTELLIgENT BACnet (Indoor Units fee)
PP-SC-INDOOR
CA-SC-1
COMMISSIONINg OF COMMUNICATIONS ADAPTER (Base fee for each Comm. Adapter)
COMMISSIONINg OF COMMUNICATIONS ADAPTER (Indoor Units fee)
CA-SC-INDOOR
COMMISSIONINg OF STAIMS MANAgEMENT SYSTEM (Base fee for each overall system)
COMMISSIONINg OF STAIMS MANAgEMENT SYSTEM (Indoor Units fee)
STAIMS-SC-1
STAIMS-SC-INDOOR
AC-SC-1
PROgRAM 2-WAY SYSTEM TO ENABLE AUTO CHANgEOVER OF MODE (Base fee /Indoor Units fee)
PROgRAM 2-WAY SYSTEM TO ENABLE AUTO CHANgEOVER OF MODE (Indoor Units fee)
PROgRAM "IgNORE INDOOR POWER OFF FAILURE" FOR 2-WAY SYSTEM (Base fee /Indoor Units fee)
PROgRAM "IgNORE INDOOR POWER OFF FAILURE" FOR 2-WAY SYSTEM (Indoor Units fee)
COMMISSIONINg COMPLETED DURINg NON-BUSINESS HOURS OR NON-BUSINESS DAYS
ALL COMMISSIONINg OF SYSTEMS OR COMPONENTS OUTSIDE CONTINENTAL U.S.
AC-SC-INDOOR
IPO-SC-1
IPO-SC-INDOOR
CNBH
COUS
TRAININg - MINI SPLIT SYSTEMS (1 class per day at Customer Location)
TRAININg - MINI SPLIT SYSTEMS (2 classes / same location / same day)
TRAININg - ECOi INSTALLATION AND COMMISSIONINg TRAININg (at customer location)
TRAININg - ECOi SERVICE TRAININg (at customer location)
RP-SIT-1
RP-SIT-2
ECOi-IST
ECOi-SERT
TOUS
TRAININg (Conducted outside of the Continental U.S.)
TRAININg (On-Site Supervised ECOi installation training)
ECO-SIT-4
ECO-SIT-NR
ECO-SIT-OS
TRAININg (Supervised installation On-Site training where attendee's did not show up agreed upon)
TRAININg (Supervised installation Training Outside Continental U.S.)
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
Usage
○
○
The air conditioners listed herein are only for cooling/heating areas used by
people. Do not use the unit for foods, animals, plants, precision machines,
works of art or other objects. Doing so may cause damage to the unit. Do not
use the unit for vehicles or vessels. Doing so may cause unit water leakage
and short circuiting.
Requires a qualified technician/installer to install the air conditioner.
Improper self-installation may result in water leakage, electric shock or fire.
○
When installing in a small room, take measures to keep refrigerant leakage
within acceptable density limits, as outlined by local/national safety code
requirements.
○
Please read the Operating Instructions carefully and use the air conditioner
properly.
○
Do not install where inflammable gas may leak or inflammable objects
exist. Do not install where there is any inflammable gas emission, inflow or
leftover, or where carbon fibers are in the air. This could be the cause of fire.
Caution On Installation and Use
Location
Operation Range
Outdoor Air Intake Temperature:
Blocking air intake or outlet can be the cause of trouble including the
loss of air flow power, or short-cycled air emission drawn into the
intake. Be sure to install in an airy place.
Cooling: 14 ~ 109°F (DB) Heating: - 4 ~ 59°F (WB)
Noise Emissions
Avoid Installation in Highly Humid Locations
(1) Avoid installation where the humidity is excessive. This causes
condensation during cooling.
(2) Installation in a room where the temperature and humidity are
high around the ceiling due to sunlight will result in condensation.
Use insulation or take other preventive measures to block the
sunlight.
The noise emission rate indicated in the catalog shows values (A
scale) measured in an anechoic chamber. In actual installation
conditions, noise emission is generally greater than the indicated
rate due to surrounding noise and echoing.
Odor Emissions
Even though an air conditioner does not contain odor-emitting parts,
discharged air can, in certain conditions, have an unpleasant odor.
This is the result of odorous particles such as ones from smoke,
cosmetics, and foods, affixing themselves to the air conditioner.
Although the odor does not affect the performance, cleaning the air
filter and the inside of the air conditioner is recommended.
Exposure to Oil
Avoid installation where there is exposure to oil or soot (such as in
kitchens or machinery plants). Oil will adhere to the heat exchange.
This will lower heat exchange performance, emit mist, or deform or
damage synthetic resin parts.
Noise Caused by Electromagnetic Waves
When installing near equipment that emits electromagnetic waves,
Cleaning
After using the air conditioner for several seasons, the insides
become dirty and this results in low performance. In addition to
regular cleaning, a maintenance contract with a service person is
recommended.
be sure that the air conditioner does not suffer noise damage.
Remote Control Wiring
For remote control wiring and control wiring between indoor units,
do not install with the power wiring (208/230V) in the same tube nor
wherever power wiring exists. Doing so may cause a malfunction
Features of Heat Pump Heating
Heating power (kW) indicated in the catalog is based on the following
conditions: outdoor temperature of 47°F (DB) and indoor temperature of
70°F (DB), as specified by ARI. Heating capacity decreases as outdoor
temperature drops. Therefore, if heating power is insufficient due to low
outdoor temperature, use the air conditioner together with other heating
equipment. When heated air rises and collects in a room with a high
ceiling, install an air circulator as well.
ISO Certification
SANYO Electric Air Conditioning Co., Ltd. (Tochigi japan)
ISO 9001
Certificate Number: jQ116B
ISO 14001
Certificate Number: EC00j0303-33
Do not install an air conditioner in a room where the limit density will be exceeded if refrigerant leaks. The refrigerant (R410A) used by this system is it-
self a safe refrigerant; however, if for some reason the refrigerant leaks and the limit density is exceeded, there is a risk of injury to persons due to a lack
of oxygen. For further information, ask your dealer or consult references such as an engineering manual to ensure you install the air conditioner correctly.
• Includes ECOi Installation & Commissioning procedures and much more.
For further information and training or to request additional product catalogs, please contact:
SaNyO North america Corporation
Commercial Solutions Division
1690 Roberts Blvd., NW Suite 110
Kennesaw, gA 30144
Phone: (678) 355-6635
Fax: (678) 355-6684
©2011 SANYO North America Corporation. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
CSDHVACECO0111
|