Quadra Fire Indoor Fireplace QF130 User Guide

R
Owner’s Manual  
Installation and Operation  
Models:  
QFI30  
QFI35  
NOTICE  
DO NOT DISCARD THIS MANUAL  
• Important operating  
and maintenance  
instructions included.  
• Read, understand and follow  
these instructions for safe  
installation and operation.  
• Leave this manual with  
party responsible for use  
and operation.  
WARNING  
WARNING: If the information in these  
instructions is not followed exactly, a fire  
or explosion may result causing property  
damage, personal injury, or death.  
HOT SURFACES!  
Glass and other surfaces are hot during  
operation AND cool down.  
Hot glass will cause burns.  
DO NOT touch glass until it is cooled  
• NEVER allow children to touch glass  
• Keep children away  
DO NOT store or use gasoline or other am-  
mable vapors and liquids in the vicinity of this  
or any other appliance.  
• CAREFULLY SUPERVISE children in same room as  
fireplace.  
• Alert children and adults to hazards of high temperatures.  
• What to do if you smell gas  
- DO NOT try to light any appliance.  
High temperatures may ignite clothing or other flammable  
materials.  
- DO NOT touch any electrical switch. DO  
NOT use any phone in your building.  
• Keep clothing, furniture, draperies and other flammable  
materials away.  
- Immediately call your gas supplier from a  
neighbor’s phone. Follow the gas suppli-  
er’s instructions.  
This appliance has been supplied with an integral barrier  
to prevent direct contact with the xed glass panel. DO  
NOT operate the appliance with the barrier removed.  
- If you cannot reach your gas supplier, call  
Contact your dealer or Hearth & Home Technologies if the  
barrier is not present or help is needed to properly install one.  
the fire department.  
• Installation and service must be performed  
by a qualified installer, service agency, or the  
gas supplier.  
In the Commonwealth of Massachusetts installation must be  
performed by a licensed plumber or gas fitter.  
ACO detector shall be installed in the room where the appliance  
in installed.  
This appliance may be installed as an OEM installation in  
manufactured home (USA only) or mobile home and must be  
installed in accordance with the manufacturer’s instructions  
and the manufactured home construction and safety standard,  
Title 24 CFR, Part 3280 or Standard for Installation in Mobile  
Homes, CAN/CSA Z240MH, in Canada.  
Installation and service of this appliance should be  
performed by qualified personnel. Hearth & Home  
Technologies suggests NFI certified or factory trained  
professionals, or technicians supervised by an NFI  
certified professional.  
This appliance is only for use with the type(s) of gas indicated  
on the rating plate.  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Safety Alert Key:  
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.  
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.  
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.  
• NOTICE: Used to address practices not related to personal injury.  
Table of Contents  
A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 4  
C. Gas Line. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
D. Fireplace Conversion Notice . . . . . . . . . . . . . . . . . . . . . . 20  
E. Electrical Outlet Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
1 Listing and Code Approvals  
8 Installing Vent Pipe and Appliance  
A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
B. Glass Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
C. BTU Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
D. High Altitude Installations. . . . . . . . . . . . . . . . . . . . . . . . . . 6  
E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 6  
F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 6  
G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
A. Vent Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
B. Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
C. Connecting Vent Pipe. . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
D. Placing, Securing and Leveling the Appliance . . . . . . . . . 22  
E. Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
F. Installing Adaptor and Termination Cap . . . . . . . . . . . . . . 23  
User Guide  
9 Gas Information  
A. Fuel Conversion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
D. High Altitude Installations. . . . . . . . . . . . . . . . . . . . . . . . . 24  
2 Operating Instructions  
A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
C. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
D. Decorative Doors, Fronts and Surrounds. . . . . . . . . . . . . . 8  
E. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
F. Remote Controls, Wall Controls and Wall Switches. . . . . . 8  
G. IPI Battery Tray/Battery Installation . . . . . . . . . . . . . . . . . . 8  
H. Control Module Operation . . . . . . . . . . . . . . . . . . . . . . . . . 9  
I. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
J. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 10  
K. After Appliance is Lit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
L. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 11  
10 Electrical Information  
A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
B. IntelliFire Plus™ Ignition System Wiring . . . . . . . . . . . . . 25  
C. Optional Accessories Requirements . . . . . . . . . . . . . . . . 26  
D. Fan Wiring with Remote. . . . . . . . . . . . . . . . . . . . . . . . . . 27  
E. Control Module Operation . . . . . . . . . . . . . . . . . . . . . . . . 27  
11 Finishing  
A. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 28  
3 Maintenance and Service  
12 Appliance Setup  
A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 12  
B. Maintenance Tasks-Service Technician . . . . . . . . . . . . . . 13  
A. Remove Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 29  
B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 29  
C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
D. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
E. Place the Lava Rock . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
F. Ember Placement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
G. Install the Log Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . 30  
H. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 36  
I. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36  
Installer Guide  
4 Getting Started  
A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 15  
B. Design and Installation Considerations . . . . . . . . . . . . . . 16  
C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 16  
D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 16  
13 Troubleshooting  
5 Fireplace Size Requirements  
A. IntelliFire Plus™ Ignition System . . . . . . . . . . . . . . . . . . . 37  
A. Minimum Fireplace Opening . . . . . . . . . . . . . . . . . . . . . . 17  
B. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 18  
14 Reference Materials  
A. Appliance Dimension Diagram. . . . . . . . . . . . . . . . . . . . . 39  
B. Vent Kits Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 40  
C. Service Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42  
D. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46  
6 Termination Locations  
A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 19  
7 Installation Preparation  
A. Inspection and Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . 20  
B. Flue Damper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
B. Limited Lifetime Warranty  
4
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Limited Lifetime Warranty (continued)  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Listing and Code Approvals  
1
A. Appliance Certification  
D. High Altitude Installations  
NOTICE: If the heating value of the gas has been reduced,  
these rules do not apply. Check with your local gas utility  
or authorities having jurisdiction.  
MODELS: QFI30, QFI35  
LABORATORY: Underwriters Laboratories, Inc. (UL)  
TYPE: Vented Gas Fireplace Heater  
STANDARD: ANSI Z21.88-2009 CSA 2.33-2009  
Vented Gas Fireplace Heaters  
When installing above 2000 feet elevation:  
• In the USA: Reduce input rate 4% for each 1000 feet  
above 2000 feet.  
• In CANADA: Reduce input rate 10% for elevations  
between 2000 feet and 4500 feet. Above 4500 feet,  
consult local gas utility.  
This product is listed to ANSI standards for “Vented Gas  
Appliance Heaters” and applicable sections of “Gas Burn-  
ing Heating Appliances for Manufactured Homes and  
Recreational Vehicles”, and “Gas Fired Appliances for  
Use at High Altitudes”.  
Check with your local gas utility to determine proper  
orifice size.  
E. Non-Combustible Materials Specification  
Quadra-Fire gas inserts are designed for installations into  
solid fuel masonry or factory built fireplaces that have been  
installed in accordance with the National, Provincial, State  
and local building codes. Fireplaces are to be constructed  
of non-combustible materials and, in the absence of local  
or regional codes, meet criteria of NFPA211. No additional  
outside air source is required.  
Material which will not ignite and burn. Such materials are  
those consisting entirely of steel, iron, brick, tile, concrete,  
slate, glass or plasters, or any combination thereof.  
Materials that are reported as passing ASTM E 136,  
Standard Test Method for Behavior of Materials in a  
Vertical Tube Furnace at 750 ºC and UL763 shall be  
considered non-combustible materials.  
NOTICE: This installation must conform with local codes.  
In the absence of local codes you must comply with the  
National Fuel Gas Code, ANSI Z223.1-latest edition in  
the U.S.A. and the CAN/CGA B149 Installation Codes in  
Canada.  
F. Combustible Materials Specification  
Materials made of or surfaced with wood, compressed pa-  
per, plant fibers, plastics, or other material that can ignite  
and burn, whether flame proofed or not, or plastered or  
unplastered shall be considered combustible materials.  
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  
This appliance is tested and approved as either supplemen-  
tal room heat or as a decorative appliance. It should not be  
factored as primary heat in residential heating calculations.  
G. Electrical Codes  
NOTICE: This appliance must be electrically wired and  
grounded in accordance with local codes or, in the absence  
of local codes, with National Electric Code ANSI/NFPA  
70-latest edition or the Canadian Electric Code CSA  
C22.1.  
B. Glass Specifications  
This appliance is equipped with 5 mm ceramic glass. Re-  
place glass only with 5 mm ceramic glass. Please contact  
your dealer for replacement glass.  
• A 120 VAC circuit for this product must be protected with  
ground-fault circuit-interrupter protection, in compliance  
with the applicable electrical codes, when it is installed in  
locations such as in bathrooms or near sinks.  
C. BTU Specifications  
Maximum  
Input  
BTU/h  
Minimum  
Input  
BTU/h  
Orifice  
Size  
(DMS)  
Models  
(U.S. or Canada)  
US  
32,000  
28,800  
35,000  
33,250  
31,000  
27,500  
35,000  
31,000  
18,000  
16,200  
18,500  
18,250  
15,500  
14,500  
17,000  
15,500  
#35  
#36  
#33  
#34  
#51  
#52  
#50  
#51  
(0-2000 FT)  
QFI30 (NG)  
QFI35 (NG)  
QFI30 (LP)  
QFI35 (LP)  
CANADA  
(2000-4500 FT)  
US  
(0-2000 FT)  
CANADA  
(2000-4500 FT)  
US  
(0-2000 FT)  
CANADA  
(2000-4500 FT)  
US  
(0-2000 FT)  
CANADA  
(2000-4500 FT)  
6
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User Guide  
Operating Instructions  
2
• Keep remote controls out of reach of children.  
A. Gas Fireplace Safety  
• Never leave children alone near a hot fireplace, whether  
operating or cooling down.  
WARNING  
HOT SURFACES!  
Teach children to NEVER touch the fireplace.  
Glass and other surfaces are hot during  
operation AND cool down.  
• Consider not using the fireplace when children will be  
present.  
Hot glass will cause burns.  
DO NOT touch glass until it is cooled  
• NEVER allow children to touch glass  
• Keep children away  
Contact your dealer for more information, or visit: www.  
hpba.org/safety-information.  
To prevent unintended operation when not using your fire-  
place for an extended period of time (summer months,  
vacation/trips, etc):  
• CAREFULLY SUPERVISE children in same room as  
fireplace.  
• Alert children and adults to hazards of high temperatures.  
• Remove batteries from remote controls.  
• Turn off wall controls.  
High temperatures may ignite clothing or other  
flammable materials.  
• Keep clothing, furniture, draperies and other flammable  
materials away.  
B. Your Fireplace  
This appliance has been supplied with an integral barrier  
to prevent direct contact with the xed glass panel. DO  
NOT operate the appliance with the barrier removed.  
WARNING! DO NOT operate fireplace before read-  
ing and understanding operating instructions. Failure  
to operate replace according to operating instructions  
could cause re or injury.  
Contact your dealer or Hearth & Home Technologies if the  
barrier is not present or help is needed to properly install one.  
If you expect that small children or vulnerable adults may  
come into contact with this fireplace, the following precau-  
tions are recommended:  
• Install a physical barrier such as:  
- A decorative firescreen.  
- Adjustable safety gate.  
• Install a switch lock or a wall/remote control with child  
protection lockout feature.  
APPLIANCE INSTALLED IN EXISTING  
SOLID FUEL FIREPLACE  
DECORATIVE DOORS  
(NOT SHOWN)  
SECTION 2.D.  
FIXED GLASS ASSEMBLY  
(NOT SHOWN)  
MANTEL  
SECTION  
5.B AND  
11.A  
SECTION 12.H.  
HEARTH  
CLEAR SPACE  
SECTION 2.C.  
Figure 2.1 General Operating Parts  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
C. Clear Space  
E. Fixed Glass Assembly  
WARNING! DO NOT place combustible objects in front  
of the replace or block louvers. High temperatures may  
start a re. See Figure 2.2.  
See Section 12.H.  
F. Remote Controls, Wall Controls and Wall  
Switches  
Avoid placing candles and other heat-sensitive objects on  
mantel or hearth. Heat may damage these objects.  
Follow the instructions supplied with the control installed  
to operate your fireplace:  
For safety:  
• Install a switch lock or a wall/remote control with child  
protection lockout feature.  
APPLIANCE INSTALLED IN EXISTING  
SOLID FUEL FIREPLACE  
• Keep remote controls out of reach of children.  
See your dealer if you have questions.  
G. IPI Battery Tray/Battery Installation  
The IntelliFire PlusTM system has a battery backup option.  
Battery longevity and performance will be affected by the  
service temperatures of this appliance. Batteries should only  
be used as a power source in the event of an emergency  
such as an outage.  
NOTICE: Batteries should only be used as a power source  
in the event of an emergency such as an outage.  
Figure 2.2 Clear Space  
D. Decorative Doors, Fronts and Surrounds  
WARNING! Risk of Fire! Install ONLY doors, fronts or  
surrounds approved by Hearth & Home Technologies.  
Unapproved doors or fronts may cause appliance to over-  
heat.  
This appliance has been supplied with an integral  
barrier to prevent direct contact with the xed glass  
panel. DO NOT operate the appliance with the barrier  
removed.  
Contact your dealer or Hearth & Home Technologies if  
the barrier is not present or help is needed to properly  
install one.  
For more information refer to the instructions supplied with  
your decorative door or front.  
8
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Module Reset  
H. Control Module Operation  
This module may lock-out under certain conditions.  
When this occurs, the appliance will not ignite or  
respond to commands. The module will go into lock-out  
mode by emitting three audible beeps, then continuously  
displaying a RED/GREEN error code at its status  
indicator LED.  
1. The control module has an ON/OFF/REMOTE selector  
switch that must be set. See Figure 2.3.  
OFF Position: Appliance will ignore all power inputs and  
will not respond to any commands from a wall switch or  
remote. The unit should be in the OFF position during  
installation, service, battery installation, fuel conversion,  
and in the event that the control goes into LOCK-OUT  
mode as a result of an error code.  
Check battery tray. Remove batteries if installed.  
Batteries should only be installed for use during power  
outages. See Section G.  
ON Position: Appliance will ignite and run continuously  
in the HI flame setting, with no adjustment in flame  
output. This mode of operation is primarily used for  
initial installation or power outage operation with battery  
backup.  
Locate the module selector switch. (See Figure 2.3).  
Set the module selector switch to the OFF position.  
Wait five (5) minutes to allow possible accumulated gas  
to clear.  
REMOTE Position: Appliance will initiate commands  
from an optional wired wall switch and/or the wireless  
remote (RC300).  
Set the module selector switch to ON or REMOTE  
position.  
Start the appliance.  
2. If using a wired wall switch with the module in REMOTE  
mode, the flame output can be adjusted with the HI/LO  
selector switch on the module. See Figure 2.3. Note  
that the flame HI/LO selector switch will become inactive  
once an optional remote control (RC200/RC300) is  
programmed to the control module. Note that the control  
module will always ignite the fireplace on HI and remain  
so for the initial 10 seconds of operation. If the HI/LO  
is switched to the LO position, the flame output will  
automatically drop to the lowest setting after the flame  
has been established for 10 sec. After this 10 second  
period, the flame can be adjusted from HI to LO with  
the switch.  
WARNING! Risk of Explosion! DO NOT press the mod-  
ule reset switch more than one time within a ve minute  
time period. Gas may accumulate in rebox. Call a quali-  
ed service technician.  
I. Before Lighting Fireplace  
Before operating this fireplace for the first time, have a  
qualified technician:  
• Verify all shipping materials have been removed from  
inside and/or underneath the firebox.  
• Review proper placement of logs, ember material and/  
or other decorative materials.  
3. The control module has safety feature that automatically  
shuts down the fireplace after 9 hours of continuous  
operation without receiving a command from the RC300  
remote.  
• Check the wiring.  
• Check the air shutter adjustment.  
• Ensure that there are no gas leaks.  
4. If you intend to use both an optional wired wall switch  
and the RC300 remote control to operate your fireplace,  
the wall switch will override any commands given by  
the remote.  
• Ensure that the glass is sealed and in the proper position  
and that the integral barrier is in place.  
WARNING! Risk of Fire/Asphyxiation! DO NOT oper-  
ate replace with xed glass assembly removed.  
• An Intellifire Plusignition system is standard with this  
appliance.  
SELECTOR  
SWITCH  
STATUS INDICATOR LED  
FLAME HI/LO SWITCH  
NG/LP SETTING  
Figure 2.3 Control Module  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
J. Lighting Instructions (IPI)  
The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the transformer. To prolong bat-  
tery life, remove them when using the transformer.  
FOR YOUR SAFETY  
LIGHTING  
READ BEFORE LIGHTING  
INSTRUCTIONS (IPI)  
WARNING: If you do not follow these instructions exactly, a fire or explosion  
may result causing property damage, personal injury or loss of life.  
1. This appliance is equipped with an ignition  
device which automatically lights the burner.  
DO NOT try to light the burner by hand.  
• Immediately call your gas supplier  
from a neighbor’s phone. Follow the  
gas supplier’s instructions.  
A. This appliance is equipped with an  
intermittent pilot ignition (IPI) device  
which automatically lights the burn-  
er. DO NOT try to light the burner by  
hand.  
GAS  
VALVE  
• If you cannot reach your gas sup-  
plier, call the fire department.  
B. BEFORE LIGHTING, smell all around  
the appliance area for gas. Be sure to  
smell next to the floor because some  
gas is heavier than air and will settle  
on the floor.  
C. DO NOT use this appliance if any  
part has been under water. Imme-  
diately call a qualified service tech-  
nician to inspect the appliance and  
to replace any part of the control  
system and any gas control which  
has been under water.  
2. Wait five (5) minutes to clear out any gas.  
Then smell for gas, including near the floor. If  
you smell gas, STOP! Follow “B” in the Safety  
Information located on the left side of this la-  
bel. If you do not smell gas, go to next step.  
WHAT TO DO IF YOU SMELL GAS  
DO NOT try to light any appliance.  
3. To light the burner:  
DO NOT touch any electric switch; do  
not use any phone in your building.  
Equipped with wall switch: Turn ON/OFF switch  
to ON.  
Equipped with remote or wall control: Press  
ON or FLAME button.  
WARNING: CAUTION:  
Equipped with thermostat: Set temperature to  
desired setting.  
Hot while in operation. DO NOT touch.  
Keep children, clothing, furniture, gaso-  
line and other liquids having flammable  
vapors away.  
DO NOT CONNECT LINE VOLT-  
AGE (110/120 VAC OR 220/240  
VAC) TO THE CONTROL VALVE.  
4. If the appliance does not light after three tries,  
call your service technician or gas supplier.  
Improper installation, adjustment, al-  
teration, service or maintenance can  
cause injury or property damage. Re-  
fer to the owner’s information manual  
provided with this appliance.  
TO TURN OFF  
GAS TO APPLIANCE  
1. Equipped with wall switch: Turn ON/OFF switch  
DO NOT operate the appliance with  
fixed glass assembly removed, cracked  
or broken. Replacement of the fixed  
glass assembly should be done by a  
licensed or qualified service person.  
to OFF.  
This appliance needs fresh air for  
safe operation and must be installed  
so there are provisions for adequate  
combustion and ventilation air.  
Equipped with remote or wall control: Press  
OFF button.  
NOT FOR USE  
WITH SOLID FUEL  
Equipped with thermostat: Set temperature to  
lowest setting.  
If not installed, operated, and main- For use with natural gas and propane.  
tained in accordance with the manufac- A conversion kit, as supplied by the  
turer’s instructions, this product could manufacturer, shall be used to convert  
expose you to substances in fuel or this appliance to the alternate fuel.  
2. Service technician should turn off electric  
power to the control when performing service.  
fuel combustion which are known to the  
State of California to cause cancer, birth  
Also Certified for Installation in a  
Bedroom or a Bedsitting Room.  
593-913G  
defects, or other reproductive harm.  
For assistance or additional informa-  
Keep burner and control compartment  
tion, consult a qualified installer, ser-  
clean. See installation and operating  
vice agency or the gas supplier.  
instructions accompanying appliance.  
For additional information on operating your  
Final inspection by  
10  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
K. After Appliance is Lit  
Initial Break-in Procedure  
• The appliance should be run three to four hours  
continuously on high.  
• Turn the appliance off and allow it to completely cool.  
• Remove fixed glass assembly. See Section 12.H.  
• Clean fixed glass assembly. See Section 3.  
• Replace the fixed glass assembly and run continuously  
on high an additional 9 hours.  
This cures the materials used to manufacture the fire-  
place.  
NOTICE! Open windows for air circulation during ap-  
pliance break-in.  
• Some people may be sensitive to smoke and odors.  
• Smoke detectors may activate.  
L. Frequently Asked Questions  
ISSUE  
SOLUTIONS  
This is a result of gas combustion and temperature variations. As the appliance warms, this  
condensation will disappear.  
Condensation on the glass  
This is a result of normal operation and the flames will begin to yellow as the appliance is al-  
lowed to burn for 20 to 40 minutes.  
Blue ames  
When first operated, this appliance may release an odor for the first several hours. This is caused  
by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor may  
also be released from finishing materials and adhesives used around the appliance.  
Odor from appliance  
This is a normal result of the curing process of the paint and logs. Glass should be cleaned  
within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing  
process. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. See  
your dealer.  
Film on the glass  
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to  
the sound produced by a furnace or heating duct. This noise does not affect the operation or  
longevity of the appliance.  
Metallic noise  
In an intermittent pilot ignition system (IPI), the pilot flame should turn off when appliance is  
turned off. Some optional control systems available with IPI models may allow pilot flame to  
remain lit.  
Is it normal to see the pilot flame burn  
continually?  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Maintenance and Service  
3
Doors, Surrounds, Fronts  
Any safety screen or guard removed for servicing must be  
replaced prior to operating the appliance.  
Frequency: Annually  
By: Homeowner  
When properly maintained, your appliance will give you  
many years of trouble-free service. We recommend an-  
nual service by a qualified technician.  
Tools needed: Protective gloves, stable work surface  
• Assess condition of screen and replace as necessary.  
A. Maintenance Tasks-Homeowner  
• Inspect for scratches, dents or other damage and repair  
as necessary.  
Installation and repair should be done by a qualified techni-  
cian only. The appliance should be inspected before use  
and at least annually by a professional service person.  
• Check that louvers are not blocked.  
• Vacuum or dust surfaces.  
The following tasks may be performed annually by the  
homeowner. If you are uncomfortable performing any of  
the listed tasks, please call your dealer for a service ap-  
pointment.  
Remote Control  
Frequency: Seasonally  
By: Homeowner  
More frequent cleaning may be required due to lint from  
carpeting or other factors. Control compartment, burner  
and circulating air passageway of the appliance must be  
kept clean.  
Tools needed: Replacement batteries and remote con-  
trol instructions.  
• Locate remote control transmitter and receiver.  
• Verify operation of remote. Refer to remote control  
operation instructions for proper calibration and setup  
procedure.  
CAUTION! Risk of Burns! The appliance should be  
turned off and cooled before servicing.  
Glass Cleaning  
Frequency: Seasonally  
By: Homeowner  
• Place batteries as needed in remote transmitters and  
battery-powered receivers.  
• Place remote control out of reach of children.  
Tools Needed: Protective gloves, glass cleaner, drop  
cloth and a stable work surface.  
If not using your fireplace for an extended period of time  
(summer months, vacations/trips, etc), to prevent unin-  
tended operation:  
CAUTION! Handle fixed glass assembly with care.  
Glass is breakable.  
• Avoid striking, scratching or slamming glass  
• Avoid abrasive cleaners  
• Remove batteries from remote controls.  
DO NOT clean glass while it is hot  
• Prepare a work area large enough to accommodate fixed  
glass assembly and door frame by placing a drop cloth  
on a flat, stable surface.  
Note: Fixed glass assembly and gasketing may have res-  
idue that can stain carpeting or floor surfaces.  
• Remove door or decorative front from appliance and set  
aside on work surface.  
• See Section 12.H for instructions to remove fixed glass  
assembly.  
• Clean glass with a non-abrasive commercially available  
cleaner.  
- Light deposits: Use a soft cloth with soap and water  
- Heavy deposits: Use commercial fireplace glass  
cleaner (consult with your dealer)  
• Carefully set fixed glass assembly in place on appliance.  
Hold glass in place with one hand and secure glass  
latches with the other hand.  
• Reinstall door or decorative front.  
12  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Venting  
Control Compartment and Firebox Top  
Frequency: Annually  
Frequency: Seasonally  
By: Homeowner  
By: Service Technician  
Tools needed: Protective gloves and safety glasses.  
Tools needed: Protective gloves, vacuum cleaner, dust  
cloths  
• Inspect venting and termination cap for blockage or  
obstruction such plants, bird nests, leaves, snow, debris,  
etc.  
• Vacuum and wipe out dust, cobwebs, debris or pet hair.  
Use caution when cleaning these areas. Screw tips that  
have penetrated the sheet metal are sharp and should  
be avoided.  
• Verify termination cap clearance to subsequent construc-  
tion (building additions, decks, fences, or sheds). See  
Section 6.  
• Remove all foreign objects.  
• Inspect for corrosion or separation.  
• Verify unobstructed air circulation.  
• Verify weather stripping, sealing and flashing remains  
intact.  
• Inspect draft shield to verify it is not damaged or missing.  
B. Maintenance Tasks-Service Technician  
The following tasks must be performed by a qualified  
technician.  
Gasket Seal and Glass Assembly Inspection  
Frequency: Annually  
By: Service Technician  
Tools needed: Protective gloves, drop cloth and a stable  
work surface.  
• Inspect gasket seal and its condition.  
• Inspect fixed glass assembly for scratches and nicks that  
can lead to breakage when exposed to heat.  
• Confirm there is no damage to glass or glass frame.  
Replace as necessary.  
• Verify that fixed glass assembly is properly retained and  
attachment components are intact and not damaged.  
Replace as necessary.  
Logs  
Frequency: Annually  
By: Service Technician  
Tools needed: Protective gloves.  
• Inspect for damaged or missing logs. Replace as necessary.  
Refer to Section 12 for log placement instructions.  
• Verify correct log placement and no flame impingement  
causing sooting. Correct as necessary.  
Firebox  
Frequency: Annually  
By: Service Technician  
Tools needed: Protective gloves, sandpaper, steel wool,  
cloths, mineral spirits, primer and touch-up paint.  
• Inspect for paint condition, warped surfaces, corrosion  
or perforation. Sand and repaint as necessary.  
• Replace appliance if firebox has been perforated.  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Burner Ignition and Operation  
Frequency: Annually  
By: Service Technician  
Tools needed: Protective gloves, vacuum cleaner, whisk  
broom, flashlight, voltmeter, indexed drill bit set, and a  
manometer.  
• Verify burner is properly secured and aligned with pilot  
or igniter.  
• Clean off burner top, inspect for plugged ports, corrosion  
or deterioration. Replace burner if necessary.  
• Replace Glowing embers with new dime-size pieces.  
DO NOT block ports or obstruct lighting paths. Refer to  
Section 12 for proper ember placement.  
• Verify batteries have been removed from battery back-up  
IPI systems to prevent premature battery failure or  
leaking. For optimal battery life, locate the battery  
pack outside of the control cavity on the hearth. This  
placement will reduce the chances of overheating the  
batteries during extended burns which could result in  
reduced battery life or degradation.  
Figure 3.1 IPI Pilot Flame Patterns  
• Check for smooth lighting and ignition carryover to all  
ports. Verify that there is no ignition delay.  
• Inspect for lifting or other flame problems.  
• Verify air shutter setting is correct. See Section 12 for  
required air shutter setting. Verify air shutter is clear of  
dust and debris.  
• Inspect orifice for soot, dirt and corrosion. Verify orifice  
size is correct. See Service Parts List for proper orifice  
sizing.  
• Verify manifold and inlet pressures. Adjust regulator as  
required.  
• Inspect pilot flame pattern and strength. See Figure 3.1  
for proper pilot flame pattern. Clean or replace orifice  
spud as necessary.  
• Inspect thermocouple/thermopile or IPI flame sensing rod  
for soot, corrosion and deterioration. Clean with emery  
cloth or replace as required.  
• Verify that there is not a short in flame sense circuit by  
checking continuity between pilot hood and flame sense  
rod. Replace pilot as necessary. (IPI only)  
14  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installer Guide  
Getting Started  
4
A. Typical Appliance System  
NOTICE: Illustrations and photos reect typical installations and are for design purposes only. Illustrations/diagrams are not  
drawn to scale. Actual product may vary from pictures in manual  
VERTICAL TERMINATION CAP  
(SECTION 8.F)  
VENT PIPE  
(SECTION 8)  
3 INCH FLEX LINERS  
(SECTION 8)  
MANTEL AND MANTEL LEG  
SECTION 5.B AND 11.A  
SURROUND OR FRONT  
NOT SHOWN  
SECTION 2.D AND 8.D.  
HEARTH EXTENSION  
GAS LINE (SECTION 9)  
ACCESS THROUGH EXISTING  
MASONRY OR WOODBURNING  
FIREPLACE  
Figure 4.1 Typical System  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
B. Design and Installation Considerations  
D. Inspect Appliance and Components  
Quadra-Fire gas inserts are designed for installations into  
solid fuel masonry or factory built fireplaces that have  
been installed in accordance with the National, Provin-  
cial, State and local building codes. Fireplaces are to be  
constructed of non-combustible materials and, in the ab-  
sence of local or regional codes, meet criteria of NFPA  
211. No additional outside air source is required.  
• Carefully remove the appliance and components from  
the packaging.  
• The vent system components and decorative doors and  
fronts may be shipped in separate packages.  
• If packaged separately, the log set and appliance grate  
must be installed.  
• Report to your dealer any parts damaged in shipment,  
particularly the condition of the glass.  
Installation MUST comply with local, regional, state and na-  
tional codes and regulations. Consult insurance carrier, local  
building inspector, fire officials or authorities having jurisdic-  
tion over restrictions, installation inspection and permits.  
Read all of the instructions before starting the instal-  
lation. Follow these instructions carefully during the  
installation to ensure maximum safety and benefit.  
Prior to installing the gas insert:  
WARNING! Risk of Fire or Explosion! Damaged parts  
could impair safe operation. DO NOT install damaged, in-  
complete or substitute components. Keep appliance dry.  
• Have the chimney and adjacent structure inspected  
and cleaned by qualified professionals. Hearth & Home  
Technologies recommends that NFI or CSIA certified  
professionals, or technicians under the direction of certi-  
fied professionals, conduct a minimum of a NFPA 211  
Level 2 inspection of the chimney.  
Hearth & Home Technologies disclaims any responsibility for,  
and the warranty will be voided by, the following actions:  
• Replace component parts of the chimney and fireplace  
as specified by the professionals.  
• Installation and use of any damaged appliance or vent  
system component.  
• Ensure combustible mantel and surround clearances  
comply with applicable codes and regulations for solid-  
fuel fireplaces. In the absence of local or regional codes,  
refer to NFPA 211.  
• Modification of the appliance or vent system.  
• Installation other than as instructed by Hearth & Home  
Technologies.  
• Improper positioning of the gas logs or the glass door.  
• Ensure all joints are properly engaged and the chimney  
is properly secured.  
• Installation and/or use of any component part not approved  
by Hearth & Home Technologies.  
• Minimum fireplace size. See Section 5.A.  
• Gas supply piping requirements.  
• Electrical wiring requirements.  
• Finishing details.  
Any such action may cause a fire hazard.  
WARNING! Risk of Fire,/Explosion/Electric Shock!  
DO NOT use this appliance if any part has been under  
water. Call a qualied technician to inspect the appliance  
and to replace any part of the control system and/or gas  
control which has been under water.  
• Whether optional accessories—devices such as a wall  
switch or remote control—are desired.  
Improper installation, adjustment, alteration, service or  
maintenance can cause injury or property damage. For  
assistance or additional information, consult a qualified  
technician, service agency or your dealer.  
C. Tools and Supplies Needed  
Before beginning the installation be sure that the following  
tools and building supplies are available.  
Tape measure  
Pliers  
Framing material  
Flat blade screwdriver  
Phillips screwdriver  
Framing square  
Hammer  
Gloves  
Voltmeter  
Plumb line  
Level  
Electric drill and bits (1/4 in.)  
Safety glasses  
Reciprocating saw  
Manometer  
Noncorrosive leak check solution  
1/2 - 3/4 inch length, #6 or #8 Self-drilling screws  
Caulking material (300º F minimum continuous exposure  
rating)  
Stove cement (1200ºF or higher continuous exposure  
rating)  
16  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fireplace Size Requirements  
5
from the factory built firebox if attached with mechanical  
fasteners.  
A. Minimum Fireplace Opening  
Minimum fireplace opening requirements for a standard 3/4  
inch deep surround are shown in Figure 5.1. For smaller  
openings, an optional 1-1/2 inch deep surround is available  
and dimensions are shown in Figure 5.2.  
• The metal floor of the solid fuel firebox may be removed to  
facilitate the installation of the insert. The appliance may  
not be placed directly on the base of the outer wrap, a 1/4  
inch airspace must be provided between the insert and  
the floor of the outer wrap. Use the levelling legs to raise  
the insert a minimum of 1/4 inch. The original fireplace  
may never be returned to solid fuel in this condition.  
The sidewalls and top structure of the firebox may not  
be altered with the exception of removable baffles and  
dampers.  
WARNING! Risk of Fire or Burns! Provide adequate  
clearance around air openings and for service access.  
Due to high temperatures, the appliance should be locat-  
ed out of traffic and away from furniture and draperies.  
• The firebrick (refractory), glass doors, screen rails, screen  
mesh and log grates can be removed from a factory  
built firebox in order to gain minimum gas insert opening  
requirements.  
• Cutting of any sheet metal parts of the fireplace in which  
the gas fireplace insert is to be installed is prohibited,  
except the floor as tested for and as noted above.  
• Any smoke shelves, shields and baffles may be removed  
FRONT VIEW  
TOP VIEW  
SIDE VIEW  
C
A
D
E
I
G
F
H
B
MINIMUM FIREPLACE SIZE  
QFI35  
QFI30  
Location  
Inches  
23-1/2  
34-5/8  
31-9/16  
15-11/16  
24  
Millimeters  
597  
Inches  
20-1/4  
30-1/2  
27-7/16  
12-13/16  
20-1/2  
17-5/8  
14-3/4  
9-1/2  
Millimeters  
514  
A
B
Rear Width  
Front Width  
879  
775  
C
Glass Opening Width  
802  
697  
D
Glass Opening Height  
Height-Front  
398  
325  
E
610  
521  
F
Height-Rear  
21-1/16  
16  
535  
448  
G**  
H
Unit Depth  
406  
375  
Venting Depth  
10-1/2  
267  
241  
Height to Top of  
Glass Frame  
I
22  
559  
18-1/4  
464  
* Note: If exhaust collar on insert and fireplace damper do not line up, add 4 inches (102 mm) to minimum  
fireplace height for bends in vent pipe.  
**Unit depth is measured to the back of the surround to give the depth needed for installation.  
In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).  
Figure 5.1 Fireplace Opening  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
SIDE VIEW  
TOP VIEW  
1-1/2 IN.  
BD  
AD  
CD  
SURROUND  
APPLIANCE  
SURROUND  
APPLIANCE  
MINIMUM FIREPLACE SIZE  
QFI35  
QFI30  
Location  
Inches  
33-3/16  
15-1/16  
22-9/16  
Millimeters  
843  
Inches  
29-1/16  
13-7/8  
Millimeters  
738  
AD  
BD  
CD  
Alternate Unit Width  
Alternate Unit Depth  
Alternate Unit Height  
383  
352  
573  
19-1/16  
484  
* Note: If exhaust collar on insert and fireplace damper do not line up, add 4 inches (102 mm) to minimum  
fireplace height for bends in vent pipe.  
Figure 5.2 Fireplace Opening - Deep Surround  
B. Mantel and Wall Projections  
EXISTING NON-COMBUSTIBLE FACING  
WARNING! Risk of Fire! Comply with all minimum clear-  
ances to combustibles as specied. Framing or nishing  
material closer than the minimums listed must be construct-  
ed entirely of noncombustible materials (i.e., steel studs,  
concrete board, etc).  
12 IN. MAX.  
Clearance to combustible material under the insert is 1/4  
inch (6 mm). Clearance from top of replace opening for  
combustibles extending 12 inches max. is 12 inches.  
• Use leveling legs to raise insert minimum 1/4 inch (6 mm)  
above combustible material or outer wrap of factory built  
rebox.  
12 IN. MIN.  
Combustible facings must not extend behind the insert  
surround. For non-combustible material specications  
refer to section 1.E.  
Figure 5.3 Mantel Clearances  
18  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Termination Locations  
6
A. Vent Termination Minimum Clearances  
A
B
6 in. (minimum) up to 20 in.  
152 mm/508 mm  
18 in. minimum  
457 mm  
WARNING  
20 in. and over  
0 in. minimum  
Fire Risk.  
Maintain vent clearance to combustibles as  
specified.  
Gas, Wood or Fuel Oil  
Termination Cap  
DO NOT pack air space with insulation or  
other materials.  
Failure to keep insulation or other materials  
away from vent pipe may cause fire.  
B
A *  
HORIZONTAL  
OVERHANG  
Gas  
Termination  
Cap **  
2 FT.  
20 INCHES MIN.  
VERTICAL  
MIN.  
WALL  
LOWEST  
DISCHARGE  
OPENING  
GAS DIRECT VENT  
TERMINATION CAP  
X
12  
ROOF PITCH  
IS X/ 12  
*
If using decorative cap cover(s), this distance may need to be  
increased. Refer to the installation instructions supplied with the  
decorative cap cover.  
H (MIN.) - MINIMUM HEIGHT FROM ROOF  
TO LOWEST DISCHARGE OPENING  
In a staggered installation with both gas and wood or fuel oil  
terminations, the wood or fuel oil termination cap must be  
higher than the gas termination cap  
**  
Roof Pitch  
H (Min.) Ft.  
Figure 6.2 Staggered Termination Caps  
Flat to 6/12...........................................................1.0*  
Over 6/12 to 7/12.................................................1.25*  
Over 7/12 to 8/12.................................................1.5*  
Over 8/12 to 9/12.................................................2.0*  
Over 9/12 to 10/12...............................................2.5  
Over 10/12 to 11/12.............................................3.25  
Over 11/12 to 12/12.............................................4.0  
Over 12/12 to 14/12.............................................5.0  
Over 14/12 to 16/12.............................................6.0  
Over 16/12 to 18/12.............................................7.0  
Over 18/12 to 20/12.............................................7.5  
Over 20/12 to 21/12.............................................8.0  
* 3 foot minimum in snow regions  
Figure 6.1 Minimum Height From Roof To Lowest Discharge  
Opening  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
Installation Preparation  
7
Prepare the existing solid fuel masonry or factory built  
non-combustible firebox for installation.  
D. Fireplace Conversion Notice  
Permanently attach the label with the following warning to  
the inside lower back of the fireplace firebox into which the  
insert is being installed. Silicone or mechanical fasteners  
may be required to properly secure the label.  
A. Inspection and Cleaning  
Prior to installing the gas insert:  
• Have the chimney and adjacent structure inspected  
and cleaned by qualified professionals. Hearth & Home  
Technologies recommends that NFI or CSIA certified  
professionals, or technicians under the direction of certi-  
fied professionals, conduct a minimum of a NFPA 211  
Level 2 inspection of the chimney.  
WARNING! Risk of Fire! This replace has been con-  
verted for use with a gas replace insert only and cannot  
be used for burning wood or solid fuels unless all original  
parts have been replaced, and the replace re-approved  
by the authority having jurisdiction.  
• Replace component parts of the chimney and fireplace  
as specified by the professionals.  
E. Electrical Outlet Box  
An outlet box may be installed in a bottom back corner of  
the existing solid fuel masonry or factory built fireplace to  
power the appliance. Each unit ships standard with a cord  
assembly to permit blowers or other optional accessories  
to be used. The accessories plug into the new outlet box  
or may be routed out onto the hearth to a nearby outlet.  
• Ensure all joints are properly engaged and the chimney  
is properly secured.  
• Ensure combustible mantel and surround clearances  
comply with applicable codes and regulations for solid-  
fuel fireplaces. In the absence of local or regional codes,  
refer to NFPA 211.  
• Ensure chimney is constructed of non-combustible  
materials.  
• Ensure chimney is clean and in good working order.  
• Ensure that all chimney cleanouts fit properly to prevent  
air leakage into chimney.  
B. Flue Damper  
Fully lock the solid fuel fireplace’s flue damper in the open  
position, OR completely remove it.  
C. Gas Line  
Note: If the factory built fireplace has no gas access hole  
provided, an access hole of 1 inch (25 mm) diameter or  
less may be drilled through the lower sides or bottom of the  
firebox in a proper workmanship - like manner. This access  
hole must be plugged with non-combustible insulation after  
the gas supply line has been installed.  
• Install gas line into firebox cavity.  
• Check local codes and gas line sizing requirements  
following NFPA51. See Section 9.  
• It is recommended that extra length of gas line be  
installed within the existing wood burner or masonry  
fireplace to allow removal of the insert for future servicing  
needs.  
20  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing Vent Pipe and Appliance  
8
A. Vent Limits  
B. Venting Components  
The abbreviations listed in this vent table key are used in  
the vent diagrams.  
CAUTION! Risk of Cuts/Abrasions/Flying Debris.  
Wear protective gloves and safety glasses during instal-  
lation. Sheet metal edges are sharp.  
Description  
The vertical vent termination system installed on this model  
includes:  
Minimum Vertical Run Length 10 ft.  
Maximum Vertical Run Length 50 ft.  
• Flexible vent pipe for exhaust air (included with vent kit).  
• One length of 3-inch flexible vent pipe for combustion  
air (included with vent kit).  
Horizontal venting is NOT allowed.  
Vertical terminations are measured to top of chimney.  
• One pipe-to-cap adaptor (included with vent kit).  
• One vertical termination cap (included with vent kit).  
This appliance is listed for use with LINK-DV systems  
and components only. It is permissible to extend venting  
above existing chimney (within specified maximum verti-  
cal limits) using SL-D series or Dura Vent GS series 4 in.  
x 6-5/8 in. gas direct-vent pipe. Connection is made us-  
ing DV-46DVA-GK. The vent must be terminated with the  
cap supplied with the LINK-series vent kit.  
C. Connecting Vent Pipe  
Reference instructions in the termination kit.  
Î
• Install the 3-inch flexible vent pipe(s) down through the  
chimney.  
WARNING! Risk of Fire/Explosion/Asphyxiation! Do  
NOT connect this gas appliance to a chimney ue serving  
a separate solid fuel or gas burning appliance.  
• Secure the exhaust flexible vent pipe to the exhaust  
starting collar on top of the appliance with three screws  
and seal with stove cement rated for continuous  
exposure to 1200ºF or higher. See Figure 8.1.  
• May impair safe operation of this appliance or other  
appliances connected to the ue.  
• Vent this appliance directly outside.  
• Use 3 screws to attach the section of inlet air vent to  
the inlet collar on the collar slide plate and seal with  
stove cement rated for continuous exposure to 1200ºF  
or higher. See Figure 8.1. NOTE: The collar slide plate  
may be removed from appliance to aid installation.  
• Use separate vent system for this appliance.  
CAUTION! ALL vent specifications MUST be followed.  
This product is tested and listed to these specications.  
Appliance performance will suffer if specications are not  
followed.  
TERMINATION  
CAP  
ADAPTER  
INLET  
COLLAR  
EXHAUST  
COLLAR  
INLET AIR STARTING COLLAR  
LOCKING TAB  
EXHAUST  
AIR  
VENT PIPE  
V = 10 FT. MINIMUM  
50 FT. MAXIMUM  
STARTING COLLAR BRACKET  
EXHAUST STARTING COLLAR  
HANDLE  
INLET AIR  
VENT PIPE  
INLET AIR STARTING COLLAR  
NOTE: TO ACHIEVE OPTIMUM PERFOR-  
MANCE OF INSERT, MINIMIZE OR AVOID  
BENDS IN EXHAUST VENT PIPE.  
STARTING COLLAR BRACKET  
EXHAUST STARTING COLLAR  
Figure 8.1  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
WARNING! Risk of Fire! Only an approved Hearth &  
Home Technologies surround may be used to cover inte-  
gral grills on solid fuel burning replaces. No other com-  
ponents such as shrouds, sheetmetal plates, etc., may be  
used to seal off vents.  
CUT AND BEND  
FLASHING AS NEEDED  
TO FIT CHIMNEY  
WARNING! Risk of Explosion! Failure to position the  
parts in accordance with these diagrams or failure to use  
only parts specically approved with this appliance may  
result in property damage or personal injury.  
SEALANT  
ADHESIVE  
WARNING! Risk of Explosion/Combustion Fumes!  
Connect vent sections per installation instructions.  
• Connect exhaust vent pipe ONLY to exhaust starting  
collar and termination cap center collar.  
• Connect inlet air vent ONLY to inlet air collar on appliance  
and the termination cap inlet air collar.  
DO NOT allow vent to sag below connection point to  
appliance.  
Figure 8.2  
• Trim chimney top plate to minimize excess overhang or  
bend over flue tile (see Figure 8.2).  
• Place 3/8 inch bead of 300º F silicone on flue tile top.  
D. Placing, Securing and Leveling the Appli-  
ance  
E. Remote Control  
IPI Models:  
• Install insert (without surround attached) into existing  
fireplace while pulling collar slide plate forward.  
If a remote control kit is used to control blower function,  
the Auxiliary 300 module can only be placed in the control  
cavity to the right of the control panel. See Figure 8.3.  
• Install gas line into hole provided on insert side.  
• If applicable install remote control wires into insert side  
(see Section 8.E).  
• Secure collar slide plate to appliance by placing locking  
handle into position with locking tabs (see Figure 8.1)  
and secure with #8 screw.  
• Level the appliance from side to side and front to back. If  
necessary, use the leveling legs included with the manual  
bag to set each corner of the base.  
• Position any excess flexible vent pipe back up into  
chimney without sagging. Twist and push flex vent  
together to shorten.  
• Install fiberglass insulation pieces to back face of  
surround.  
AUXILIARY 300 MODULE  
• Attach surround. Follow instructions for surround  
installation included with the front.  
Figure 8.3 Location of AUX300 for Remote Control  
Blower Function - IPI  
• Push insert into the opening so that it tightly overlaps  
the fireplace opening.  
22  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION! Risk of Cuts/Abrasions/Flying Debris.  
Wear protective gloves and safety glasses during instal-  
lation. Sheet metal edges are sharp.  
F. Installing Adaptor and Termination Cap  
For installation of termination cap see minimum vent  
heights for various pitched roofs (see Figure 8.4) .  
Damper Flashing Kit (Optional)  
To install adaptor see Figure 8.5.  
For use with LINK-DV30B or LINK-DV4-30B Liner Kit.  
Note: Damper may have to be removed to use this kit.  
• Run flex liners through 3 in. holes in damper flashing.  
HORIZONTAL  
OVERHANG  
2 FT.  
20 INCHES MIN.  
VERTICAL  
MIN.  
• Attach damper flashing to firebox roof with self tapping  
WALL  
screws included in kit.  
LOWEST  
DISCHARGE  
OPENING  
GAS DIRECT VENT  
TERMINATION CAP  
CLASS A PIPE  
X
12  
ROOF PITCH  
IS X/ 12  
H (MIN.) - MINIMUM HEIGHT FROM ROOF  
TO LOWEST DISCHARGE OPENING  
Roof Pitch  
H (Min.) Ft.  
Roof Pitch  
H (Min.) Ft.  
Over 11/12 to 12/12.......4.0  
Over 12/12 to 14/12.......5.0  
Over 14/12 to 16/12.......6.0  
Over 16/12 to 18/12.......7.0  
Over 18/12 to 20/12.......7.5  
Over 20/12 to 21/12.......8.0  
Flat to 6/12....................1.0*  
Over 6/12 to 7/12........1.25*  
Over 7/12 to 8/12..........1.5*  
Over 8/12 to 9/12..........2.0*  
Over 9/12 to 10/12........2.5*  
Over 10/12 to 11/12.....3.25  
Figure 8.5  
* 3 foot minimum in snow regions  
Figure 8.4 Minimum Height from Roof to Lowest Discharge  
Opening  
To prevent odors and cold drafts, the chimney must be sealed around the vent  
with non-combustible blanket insulation or field fabricated metal plates.  
Note: The LINK-DV4-30B  
system REQUIRES this insulation.  
Masonry  
Factory Built  
Wood Burning  
LINK-DV30B  
Installation  
LINK-DV4-30B  
Installation  
TERMINATION  
CAP  
OPTIONAL LINK-ZC-ADPB  
FOR USE WITH CLASS A  
WOODBURNING PIPE  
EXHAUST  
AIR  
EXHAUST  
AIR  
VENT PIPE  
VENT PIPE  
OR  
WARNING:  
DO NOT BLOCK  
THIS PIPE END!  
Note: Untwist the  
pipe while extend-  
ing it, to achieve full  
30’ length.  
INLET AIR  
VENT PIPE  
INLET AIR  
VENT PIPE  
Remove 18 inch x 18 inch flashing on cap by removing 3  
screws. Connect both the LINK-ZC-ADPB to Class A Pipe  
and the termination cap to the LINK-ZC-ADPB with the  
self tapping screws provided.  
Figure 8.6  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
Gas Information  
9
A. Fuel Conversion  
C. Gas Connection  
• Make sure the appliance is compatible with available gas  
types.  
• Refer to Reference Section 15 for location of gas line  
access in appliance.  
• Conversions must be made by a qualified technician  
(NFI certified or factory-trained) using Hearth & Home  
Technologies specified and approved parts.  
• Gas line may be run through knockout(s) provided.  
• The gap between supply piping and gas access hole may  
be caulked with caulk with a minimum of 300ºF continuous  
exposure rating or stuffed with non-combustible, unfaced  
insulation to prevent cold air infiltration.  
B. Gas Pressure  
• Optimum appliance performance requires proper input  
pressures.  
• Ensure that gas line does not come in contact with outer  
wrap of the appliance. Follow local codes.  
• Gas line sizing requirements will be determined in ANSI  
Z223.1 National Fuel Gas Code in the USA and CAN/  
CGA B149 in Canada.  
• Pipe incoming gas line into valve compartment.  
• Connect incoming gas line to the 1/2 in. (13 mm)  
connection on manual shutoff valve.  
• Pressure requirements are:  
WARNING! Risk of Fire/Explosion! Support control  
when attaching pipe to prevent bending gas line.  
Gas Pressure  
Minimum inlet pressure  
Maximum inlet pressure  
Manifold pressure  
Natural Gas  
5.0 in. w.c.  
10.0 in. w.c.  
3.5 in. w.c.  
Propane  
11.0 in. w.c.  
13.0 in. w.c.  
10.0 in. w.c.  
• A small amount of air will be in the gas supply lines.  
WARNING! Risk of Fire/Explosion! Gas build-up during  
line purge could ignite.  
• Purge should be performed by technician certified by  
NFI or factory-trained.  
• Ensure adequate ventilation.  
WARNING! Risk of Fire/Explosion! High pressure will  
damage valve. Low pressure may cause explosion.  
• Ensure there are no ignition sources such as sparks  
or open ames.  
• Verify inlet pressures. Verify minimum pressures when  
other household gas appliances are operating.  
Light the appliance. It will take a short time for air to purge  
from lines. When purging is complete the appliance will  
light and operate normally.  
• Install regulator upstream of valve if line pressure is  
greater than 1/2 psig.  
WARNING! Risk of Fire, Explosion or Asphyxiation!  
Check all ttings and connections with a non-corrosive  
commercially available leak-check solution. DO NOT use  
open ame. Fittings and connections could have loos-  
ened during shipping and handling.  
WARNING  
Fire Risk.  
Explosion Hazard.  
High pressure will damage valve.  
• Disconnect gas supply piping BEFORE  
pressure testing gas line at test pressures  
above 1/2 psig.  
WARNING! Risk of Fire! DO NOT change valve settings.  
This valve has been preset at the factory.  
• Close the manual shutoff valve BEFORE  
pressure testing gas line at test pressures  
equal to or less than 1/2 psig.  
D. High Altitude Installations  
NOTICE: If the heating value of the gas has been reduced,  
these rules do not apply. Check with your local gas utility  
or authorities having jurisdiction.  
Note: Have the gas supply line installed in accordance with  
local codes, if any. If not, follow ANSI 223.1. Installation  
should be done by a qualified installer approved and/or  
licensed as required by the locality. (In the Commonwealth  
of Massachusetts installation must be performed by a  
licensed plumber or gas fitter).  
When installing above 2000 feet elevation:  
• In the USA: Reduce burner orifice 4% for each 1000 feet  
above 2000 feet.  
• In the CANADA: Reduce burner orifice 10% for elevations  
between 2000 feet and 4500 feet. Above 4500 feet,  
consult local gas utility.  
Note: A listed (and Commonwealth of Massachusetts ap-  
proved) 1/2 inch (13 mm) T-handle manual shut-off valve  
and flexible gas connector are connected to the 1/2 inch  
(13 mm) control valve inlet.  
• If substituting for these components, please consult  
local codes for compliance.  
24  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Information  
10  
B. IntelliFire Plus™ Ignition System Wiring  
A. Wiring Requirements  
• Wire an outlet box (120VAC) in the bottom back corner of  
the existing solid fuel masonry or factory built fireplace to  
plug in the cord assembly. The supplied cord assembly  
may also be routed out onto the hearth to a nearby outlet.  
NOTICE: This appliance must be electrically wired  
and grounded in accordance with local codes or, in the  
absence of local codes, with National Electric Code  
ANSI/NFPA 70-latest edition or the Canadian Electric  
Code CSA C22.1.  
WARNING! Risk of Shock or Explosion! DO NOT wire  
IPI controlled appliance junction box to a switched circuit.  
Incorrect wiring will override IPI safety lockout.  
• This appliance comes standard with a 120 VAC cord  
assembly which has a female plug in to accommodate  
all control options and accessories. See Figure 10.2.  
This is required for proper operation of the appliance  
(IntelliFire Plus Ignition). An outlet box may be installed  
in a bottom back corner of the existing solid fuel masonry  
or factory built fireplace to plug in the cord assembly,  
or the supplied power cord may be routed out onto the  
hearth to a nearby outlet.  
• Refer to Figure 10.1, IPI Wiring Diagram.  
• This appliance is equipped with an IntelliFire Plus™  
control valve which operates on a 6 volt/1.5 AMP  
system.  
• Plug the 6 volt transformer plug into the cord assembly  
to supply power to the unit OR install 4 AA cell batteries  
(not included) into the battery pack before use.  
• A 120 VAC circuit for this product must be protected with  
ground-fault circuit-interrupter protection, in compliance  
with the applicable electrical codes, when it is installed in  
locations such as in bathrooms or near sinks.  
ON/OFF Switch  
• An ON/OFF switch is included with the appliance  
surround and should be attached to surround/facing.  
(See Installation instructions for remote control/fronts).  
• Low voltage and 120 VAC voltage cannot be shared  
within the same wall box.  
• If desired an additional wall switch or thermostat may  
be added to system as shown in Figure 10.1.  
WARNING! Risk of Shock or Explosion! DO NOT wire  
120V to the valve or to the appliance wall switch. Incor-  
rect wiring will damage controls.  
• An Intellifire PlusIgnition System is standard with this  
appliance.  
INTERMITTENT  
PILOT IGNITOR  
RC100 RC200  
RC300  
(OPTIONAL WALL CONTROLS)  
TO CORD ASSEMBLY  
120VAC  
MODULE  
AUX2 NOT USED FOR INSERT MODELS.  
ORG  
AUX300 MODULE  
FAN  
PROTECTIVE COVER INCLUDED  
WHT  
FLAME  
MODULATION  
TO CORD  
ASSEMBLY  
(110V)  
AUX2  
AUX1  
BATTERY PACK  
6V DC  
RED  
BLK  
RED  
BLK  
ORANGE  
(PILOT)  
ROCKER  
SWITCH  
GREEN  
(MAIN)  
BROWN  
WALL SWITCH  
OR REMOTE  
INSTALL  
GROUND  
Figure 10.1 IPI Wiring Diagram  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
• An IntelliFire Plus™ Wireless Controls or WSK-21  
wired wall switch may be used with the IntelliFire  
Plus™ Ignition System. Hearth & Home Technologies  
recommends that IntelliFire Plus™ wireless controls be  
used for their features and functionality with the Intel-  
liFire Plus™ ignition system.  
C. Optional Accessories Requirements  
• This appliance may be used with a wall switch, wall  
mounted thermostat and/or a remote control.  
To connect optional accessories, the supplied cord as-  
sembly should be used. See Figure 10.2 for a wiring  
diagram for a blower or remote.  
• A standard ON/OFF switch is compatible.  
Wiring for optional Hearth & Home Technologies approved  
accessories should be done now to avoid reconstruction.  
Follow instructions that come with those accessories.  
WARNING! Risk of Shock! Label all wires prior to dis-  
connection when servicing controls. Wiring errors can  
cause improper and dangerous operation. Verify proper  
operation after servicing.  
• Plug the cord into a convenient outlet.  
• Must use cord supplied.  
WARNING! Risk of Shock! Replace damaged wire with  
type 105° C rated wire. Wire must have high temperature  
insulation.  
PLUG  
BLOWER  
120V EXISTING  
OUTLET  
NOTE: IF ANY OF THE ORIGINAL  
WIRE AS SUPPLIED WITH THE  
APPLIANCE MUST BE REPLACED,  
IT MUST BE REPLACED WITH TYPE  
1050 C RATED WIRE.  
JUMPER WIRE  
NOTE: USE ZIPTIES TO RESTRAIN  
THE LOOSE WIRES UNDERNEATH  
THE APPLIANCE AND KEEP THEM  
AWAY FROM THE BLOWER WHEEL  
(FAN BLADES).  
TEMPERATURE  
SENSOR SWITCH  
TO VALVE  
ORG  
BLK  
WHT (2)  
GRN (2)  
BLK (2)  
GRN  
SPEED CONTROL  
(RHEOSTAT)  
BLK (2)  
GRN (2)  
BLK (2)  
BRN  
TO VALVE BRACKET  
(GROUND)  
BLK  
RED  
PLUG INTO 120V  
EXISTING OUTLET  
DC REGULATOR  
RECEPTACLE  
VARIABLE SPEED  
CONTROL  
BLK  
BLK  
BLK  
BLK  
WHT  
BLK  
GRN  
BLK  
GRN  
BLK  
BLOWERS  
BLOWER  
RECEPTACLE  
TEMPERATURE  
SENSOR SWITCH  
BLK  
GRN  
BLK  
GRN  
BLK  
WHT  
Figure 10.2 Fan Wiring Diagram  
26  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Plug two cord assembly spade connectors together.  
3. Unplug fan cord assembly from standard cord assembly.  
4. Plug fan cord assembly into AUX300 module.  
D. Fan Wiring with Remote  
This appliance may be used with an RC200 or RC300  
remote control. See Figure 10.3.  
1. Remove cord assembly spades from rheostat and  
sensor switch.  
5. Plug AUX300 module into the standard cord assembly.  
NOTICE: Fan speed and operation are controlled by the  
remote control. The sensor switch and rheostat are no  
longer needed.  
E. Control Module Operation  
See Section 2.H for control module operation instructions.  
NOTE: IF ANY OF THE ORIGINAL  
WIRE AS SUPPLIED WITH THE  
APPLIANCE MUST BE REPLACED,  
IT MUST BE REPLACED WITH TYPE  
PLUG  
1050 C RATED WIRE.  
120V EXISTING  
BLOWER  
OUTLET  
STEP 5  
NOTE: USE ZIPTIES TO RESTRAIN  
THE LOOSE WIRES UNDERNEATH  
THE APPLIANCE AND KEEP THEM  
AWAY FROM THE BLOWER WHEEL  
(FAN BLADES).  
STEPS  
1 & 2  
STEPS  
3 & 4  
SENSOR SWITCH  
WHT (2)  
GRN (2)  
BLK (2)  
BLK (2)  
GRN (2)  
BLK (2)  
SPEED CONTROL  
(RHEOSTAT)  
NOTE: SENSOR SWITCH AND  
RHEOSTATSPEED CONTROLMUST  
BE REMOVED FROM CIRCUIT IF  
SYSTEM IS CONTROLLED WITH  
RC200/RC300 REMOTE.  
PLUG INTO 120V  
EXISTING OUTLET  
BLK  
GRN  
WHT  
GRN  
BLK  
DC REGULATOR  
RECEPTICLE  
BLK  
BLOWERS  
AUX 300 MODULE  
FAN  
TO CONTROL  
MODULE  
BLK  
BLK  
BLK  
BLK  
GRN  
WHT  
GRN  
BLK  
BLOWER  
RECEPTICLE  
Figure 10.3 Wiring Diagram - Fan with RC200/RC300 Remote  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Finishing  
11  
A. Mantel and Wall Projections  
WARNING! Risk of Fire! Comply with all minimum clear-  
ances to combustibles as specied. Framing or nishing  
material closer than the minimums listed must be construct-  
ed entirely of noncombustible materials (i.e., steel studs,  
concrete board, etc).  
EXISTING NON-COMBUSTIBLE FACING  
12 IN. MAX.  
Clearance to combustible material under the insert is 1/4  
inch (6 mm). Clearance from top of replace opening for  
combustibles extending 12 inches max. is 12 inches.  
• Use leveling legs to raise insert minimum 1/4 inch (6 mm)  
above combustible material or outer wrap of factory built  
rebox.  
12 IN. MIN.  
Combustible facings must not extend behind the insert  
surround. For non-combustible material specications  
refer to section 1.E.  
Figure 11.1 Clearances to Mantels or other Combustibles  
above Appliance  
28  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appliance Setup  
12  
A. Remove Glass Assembly  
F. Ember Placement  
See Section 12.H.  
WARNING! Risk of Explosion! Follow ember placement  
instructions in manual. DO NOT place embers directly over  
burner ports. Replace ember material annually. Improperly  
placed embers interfere with proper burner operation.  
B. Remove the Shipping Materials  
Remove shipping materials from inside or underneath the  
firebox.  
Ember material is shipped with this gas appliance. To place  
the ember material:  
C. Clean the Appliance  
• Embers CANNOT be placed directly over ports. Care  
should be taken not to cover the lighting trail of ports  
(from back to front).  
Clean/vacuum any sawdust that may have accumulated  
inside the firebox or underneath in the control cavity.  
D. Accessories  
• Place dime-size pieces of Glowing Embers® just in front  
of the port trail, but not on or in between the ports (see  
Figure 12.2). Care should be taken so that the ports are  
not covered. Failure to follow this procedure will likely  
cause lighting and sooting problems.  
Install approved accessories per instructions included  
with accessories. Contact your dealer for a list of ap-  
proved accessories.  
WARNING! Risk of Fire and Electric Shock! Use ONLY  
Hearth & Home Technologies-approved optional acces-  
sories with this appliance. Using non-listed accessories  
could result in a safety hazard and will void the warranty.  
• Save the remaining ember materials for use during  
appliance servicing. The embers provided should be  
enough for 3 to 5 applications.  
E. Place the Lava Rock  
WARNING! Risk of Explosion! Follow lava rock place-  
ment instructions in manual. DO NOT place lava rock on  
burner. Improperly placed lava rock interferes with proper  
burner operation.  
EMBERS NOT  
ALLOWED IN  
PILOT AREA  
Lava rock is shipped with this gas appliance. To place  
the lava rock:  
• Lava rock CANNOT be placed on the burner.  
• Place lava rock in front of and to the sides of the  
burner.  
Figure 12.2 Placement of Embers  
PLACE LAVA ROCK IN SHADED AREA ONLY  
Figure 12.1 Placement of Lava Rock  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
29  
G. Install the Log Assembly  
Log Set Assembly: LOGS-QFI30  
Models: QFI30  
LOG SUPPORT  
SRV2227-702  
SRV2227-703  
PILOT  
BRACKET  
SRV2227-705  
SRV2227-704  
LOG PIN  
LEFT GRATE  
TINE  
RIGHT GRATE  
TINE  
SRV2227-706  
SRV2227-701  
Figure 1. Reference Points for Log Placement  
Figure 2. Refractory and Logs Installed  
Figure 3. Install Back Refractory  
CAUTION: Logs are fragile, handle with care. Install back refractory by placing it against the back of the firebox. See Figure  
3. The back refractory must be held in the upright position until the side refractory is installed. Install the left side refractory  
as shown in Figure 4. Bend the refractory tab down as shown in Figure 5. Repeat this step for the right refractory panel.  
Figure 5. Bend Refractory Tab  
Figure 4. Install Side Refractory  
30  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FLAT SPOT FOR LOG #2  
FLAT SPOT FOR LOG #5  
NOTCH  
1
LOG CORNER ALIGNS  
WITH PILOT BRACKET  
NOTCH MATES WITH LEFT  
GRATE TINE  
Figure 6. Placement of Log #1  
Figure 7. Location of Notch on Log #1  
Log #1 (SRV2227-703): Mate the notch located on the bottom of the log, with the left grate tine. See Figure 7. The back  
end of log should line up with the left edge of the pilot bracket as shown in Figure 6.  
LOG CONTACTS REFRACTORY  
LOG GROOVE  
(FOR LOG #6)  
LOG RESTS ON  
LOG CONTACTS  
REFRACTORY SUPPORT  
LOG SUPPORT  
2
3
NOTCH MATES WITH  
LOG RESTS ON BURNER  
RIGHT GRATE TINE  
Figure 8. Place Log #2  
Figure 9. Log #3  
Log #2 (SRV2227-702): Rest left end of log on the flat spot of Log 1. See Figure 6 and Figure 8. The left end of the log  
should touch the left refractory panel. The right end rests on the burner. Push the right end back, until it touches the edge  
of the log support.  
Log #3 (SRV2227-701): Mate the notch with the right grate tine as shown in Fig 9. The back of the log should rest on the  
log support as shown. Rotate the back end of the log clockwise until it contacts the right refractory panel.  
LOG GROOVE  
LOG PIN  
MATES  
(FOR LOG #6)  
WITH SLOT  
4
MATE NOTCH  
WITH GRATE BAR  
NOTCH  
Figure 10. Log #4  
Figure 11. Log #4  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31  
Log #4 (SRV2227-705): Mate the slot on the bottom of the log, shown in Figure 12, with the log pin located on the burner  
surface. The notch on the right end of the log should mate with the grate bar. See Figure 11.  
LOG END  
RESTS ON  
FLAT SPOT  
5
LOG END  
CONTACTS  
GRATE BAR  
SLOT  
Figure 12. Log #4  
Figure 13. Log #5  
Log #5 (SRV2227-706): Place the left end of the log on the flat spot of log as shown in Figure 6. The right end of log should  
rest on the burner and touches the grate bar as shown in Figure 13.  
6
LOG  
GROOVES  
MATE  
NOTCH WITH  
GRATE BAR  
Figure 14. Place Log #6  
Log #6 (SRV2227-704): Rest the left end of Log #6 on the burner. Mate the notch on the left end of log with the grate bar.  
The log should rest on both log grooves as illustrated in Figure 9 and Figure 10.  
2227-935  
32  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
G. Install the Log Assembly  
Log Set Assembly: LOGS-QFI35  
Models: QFI35  
CAUTION: Logs are fragile, handle with care.  
SRV2225-703  
SRV2225-704  
SRV2225-701  
SRV2225-702  
SRV2225-706  
SRV2225-710  
SRV2225-705  
Figure 1. Refractory and Logs Installed  
Figure 2. Install Back Refractory  
Install back refractory by placing it against the back of the firebox. The back refractory must be held in the upright position  
until the side refractory is installed. Install the left side refractory as shown in Figure 3. Bend the refractory tab down as  
shown in Figure 4. Repeat this step for the right refractory panel.  
REFRACTORY  
TAB  
Figure 3. Install Side Refractory  
Figure 4. Bend Refractory Tab  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
33  
LOG SUPPORT  
PILOT  
BRACKET  
LOG GROOVE  
CONTACTS  
GRATE TINE  
LOG PINS  
1
ANDIRONS  
LOG RESTS ON  
LOG SUPPORT  
OUTER TINES  
Figure 5.  
Figure 6. Location of Log #1  
Log #1 (SRV2225-701): Position the groove on the log with the right grate tine as shown in Figure 6. The opposite end of  
the log will rest on the log support. Rotate the opposite end of the log clockwise until it contacts the refractory panel.  
FLAT SPOTS  
FOR LOG #6 AND LOG #3  
LOG CONTACTS  
LEFT REFRACTORY  
PANEL  
SLOT  
2
MATE SLOT WITH  
GRATE TINE  
Figure 7. Place Log #2  
Figure 8. Slot on Log #2  
Log #2 (SRV2225-703): Mate the grate tine with the slot on the bottom of Log #2. The back end of the log rests on the log  
support. The side of the log will contact the left refractory as shown in Figure 7.  
POSITION LOG  
ON FLAT SPOT  
FLAT SPOT  
FOR LOG #7  
3
4
LOG CONTACTS LEFT  
REFRACTORY PANEL  
MATE LOG  
PIN WITH  
LOG SLOT  
LOG RESTS ON  
LOG SUPPORT  
LOG CONTACTS  
BACK REFRAC-  
TORY PANEL  
MATE GRATE BAR  
WITH LOG GROOVE  
Figure 10. Place Log #4  
Figure 9. Place Log #3  
Log #3 (SRV2225-702): Position the left end of the log on the flat spot of Log #2 as shown in Figure 7 and Figure 9. The  
right end of the log rests on the log support and touches the back refractory. The left end of the log should contact the left  
refractory panel.  
Log #4 SRV(2225-705): Mate the slot on the bottom of Log #4 with the right log pin. Refer to Figure 11 for location of log  
slot. Rotate the right end of the log clockwise until the groove on the end of the log mates with the grate bar.  
34  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
MATE LOG  
PINS WITH  
LOG SLOTS  
LOG SLOT  
FLAT SPOT  
FOR LOG #6  
Figure 11. Log #4  
Figure 12. Place Log #5  
Log #5 (SRV2225-710): Position Log #5 as shown in Figure 12. Mate the middle and left log pins with the two slots located  
on the bottom of the log. See Figure 13 for locations of log slots. The smaller end should be pointed toward the right side  
of the firebox.  
LOG SLOTS  
6
LOG RESTS  
ON FLAT SPOTS  
Figure 14. Place Log #6  
Figure 13. Log #5  
Log #6 (SRV2225-706): Rest the wide end of the log on the flat spot of Log #5 as shown in Figure 12 and Figure 14. Place  
the narrow end on the flat spot of Log #2. Flat spot on Log #2 is indicated in Figure 7.  
LOG RESTS  
ON FLAT SPOT  
7
LOG GROOVE  
MATES WITH  
GRATE BAR  
Figure 15. Place Log #7  
Log #7 SRV2225-704): Note the location of the groove on the underside of the log. Place the opposite end on the flat spot  
on Log #3. See Figure 9. Mate the groove on the underside of the log with the grate bar as shown in Figure 15, centered  
between the andirons.  
2225-935B  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
H. Fixed Glass Assembly  
I. Air Shutter Setting  
Air shutter settings should be adjusted by a qualified ser-  
vice technician at the time of installation. The air shutter is  
set at the factory for minimum vertical vent run. Adjust air  
shutter for longer vertical runs. See Figure 12.4.  
Removing Fixed Glass Assembly  
WARNING! Risk of Asphyxiation! Handle xed glass  
assembly with care. Inspect the gasket to ensure it is  
undamaged and inspect the glass for cracks, chips or  
scratches.  
NOTICE: If sooting occurs, provide more air by opening  
the air shutter.  
DO NOT strike, slam or scratch glass.  
DO NOT operate replace with glass removed, cracked,  
broken or scratched.  
Replace as a complete assembly.  
Removing Fixed Glass Assembly  
The glass assembly fastens to the fireplace in four  
places. Four of the fastening mechanisms are spring-  
loaded glass latches. An example of the glass latch  
is shown in Figure 12.3.  
To release glass assembly, pull the two bottom  
spring-loaded latches forward and allow them to re-  
tract away from the glass assembly. Slide the glass  
assembly outward and downward until the top latches  
disengage.  
Figure 12.4 Air Shutter  
Replacing Fixed Glass Assembly  
Tilt glass assembly toward fireplace and slide glass  
assembly upward to engage top latches. Verify top  
latches are fully engaged and then fasten the two  
bottom latches.  
Air Shutter Settings  
NG  
LP  
QFI30  
QFI35  
5/16 in.  
1/4 in.  
1/2 in.  
1/2 in.  
Figure 12.3 Fixed Glass Assembly  
36  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
13  
With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you  
do experience a problem, this troubleshooting guide will assist a qualified technician in the diagnosis of a problem and the  
corrective action to be taken. This troubleshooting guide can only be used by a qualified technician. Contact your dealer to  
arrange a service call by a qualified technician.  
A. IntelliFire Plus™ Ignition System  
Symptom  
Possible Cause  
Corrective Action  
1. Pilot won’t light.  
The ignitor/module  
makes noise, but no  
spark.  
A. Incorrect wiring.  
Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are  
connected to correct terminals on module and pilot assembly.  
B. Loose connections or electrical  
shorts in the wiring.  
Verify no loose connections or electrical shorts in wiring from mod-  
ule to pilot assembly. Verify connections underneath pilot assembly  
are tight; also verify igniter and flame sense wires are not grounding  
out to metal chassis, pilot burner, pilot enclosure, mesh screen if  
present, or any other metal object.  
C. Ignitor gap is too large.  
Verify gap of igniter to right side of pilot hood. The gap should be  
approximately .17 in. or 1/8 in. (3 mm).  
2. Pilot won’t light,  
there is no noise or  
spark.  
A. No power, transformer installed  
incorrectly, or depleted batteries.  
Verify that transformer is installed and plugged into module. Check  
voltage of transformer at connection to module. Acceptable read-  
ings of a good transformer are between 6.4 and 6.6 volts AC. Bat-  
tery power supply voltage must be at least 4 volts. If below 4 volts,  
replace batteries.  
B. A shorted or loose connection in  
wiring configuration or wiring har-  
ness.  
Remove and reinstall the wiring harness that plugs into module.  
Verify there is a tight fit. Verify pilot assembly wiring to module. Re-  
move and verify continuity of each wire in wiring harness. Replace  
any damaged components.  
C. Improper wall switch wiring.  
D. Module not grounded.  
Verify that 120/VAC power is “ON” to junction box.  
Verify black ground wire from module wire harness is grounded to  
metal chassis of appliance.  
3. Pilot sparks, but  
Pilot will not light.  
A. Gas supply.  
Verify that incoming gas line ball valve is “open”. Verify that inlet  
pressure reading is within acceptable limits.  
B. Ignitor gap is too large.  
Verify gap of igniter to right side of pilot hood. The gap should be  
approximately .17 in. or 1/8 in. (3 mm).  
C. Module is not grounded.  
D. Pilot valve solenoid  
Verify module is securely grounded to metal chassis of appliance.  
Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module.  
If below 1.5 volts, replace module. If 1.5 volts or greater, replace  
valve.  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
37  
IntelliFire Plus™ Ignition System (continued)  
Symptom  
Possible Cause  
Corrective Action  
4. Pilot lights but con-  
tinues to spark, and  
main burner will not  
ignite. (If the pilot  
continues to spark  
after the pilot flame  
has been lit, flame  
rectification has not  
occurred.)  
A. A shorted or loose connection in  
flame sensing rod.  
Verify all connections to wiring diagram in manual. Verify connec-  
tions underneath pilot assembly are tight. Verify flame sense or ig-  
niter wires are not grounding out to metal chassis, pilot burner, pilot  
enclosure or screen if present, or any other metal object.  
B. Poor flame rectification or contami- With fixed glass assembly in place, verify that flame is engulng  
nated flame sensing rod.  
flame sensing rod on left side of pilot hood. Flame sensing rod  
should glow shortly after ignition. With a multi-meter, verify that cur-  
rent in series between module and sense lead is at least 0.14 mi-  
croamps. Verify correct pilot orifice is installed and gas inlet is set to  
pressure specifications. Clean flame sensing rod with emery cloth  
to remove any contaminants that may have accumulated on flame  
sensing rod.  
C. Module is not grounded.  
Verify module is securely grounded to metal chassis of appliance.  
Verify that wire harness is firmly connected to the module.  
D. Damaged pilot assembly or con-  
Verify that ceramic insulator around the flame sensing rod is not  
cracked, damaged, or loose. Verify connection from flame sensing  
rod to white sensor wire. Clean flame sensing rod with emery cloth  
to remove any contaminants that may have accumulated on flame  
sensing rod. Verify continuity with a multi-meter with ohms set at  
lowest range. Replace pilot if any damage is detected.  
taminated flame sensing rod.  
38  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reference Materials  
14  
A. Appliance Dimension Diagram  
Dimensions are actual appliance dimensions. Use for reference only.  
A
H
S
O
Q
R
P
G
T
B
C
D
F
I
E
M
J
K
GAS LINE  
ACCESS  
ELECTRICAL  
ACCESS  
N
L
MODEL DIMENSIONS  
MODEL DIMENSIONS  
QFI35  
QFI30  
QFI35  
QFI30  
Location  
Location  
Inches Millimeters Inches Millimeters  
Inches Millimeters Inches Millimeters  
A
B
C
D
E
F
23-1/2  
34-5/8  
31-9/16  
15-11/16  
24  
597  
879  
802  
398  
610  
535  
403  
298  
518  
44  
20-3/16  
30-1/2  
27-7/16  
12-13/16  
20-1/2  
17-5/8  
14-5/8  
10-1/8  
17  
513  
775  
697  
325  
521  
448  
372  
257  
432  
44  
K
L
4-13/16  
10-1/16  
2-1/4  
5
122  
256  
57  
4-13/16  
9
122  
229  
57  
M
N
O
P
Q
R
S
T
2-1/4  
3-15/16  
5-3/16  
8
127  
130  
203  
46  
100  
132  
203  
44  
5-1/8  
8
21-1/16  
15-7/8  
11-3/4  
20-3/8  
1-3/4  
G*  
H
I
1-13/16  
2-1/4  
4-13/16  
10-1/2  
1-3/4  
2-1/4  
4-7/16  
9-1/2  
57  
57  
122  
267  
113  
241  
J
1-3/4  
*Note: Location G on Figure 14.1 is measuring the appliance depth, for installation depth reference Location G on  
Figure 5.1.  
Figure 14.1 Appliance Dimensions  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
B. Vent Kits Components  
Direct Vent Flex Liner Kits (see Figure 14.2)  
LINK-DV-30B or (LINK-DV-30): Masonry 3 inch flex liner  
kit. Expands to 30 feet. Includes: two liners, termination  
cap, flashing, and link adapter.  
LINK-DV4-30B or (LINK-DV4-30): Masonry 3 inch flex liner  
kit. Expands to 30 feet and 4 feet respectively. Includes:  
two liners, termination cap, flashing, and link adapter.  
FLASH-DAMP  
LINK-ZC-ADP  
LINK-DV-30B  
(LINK-DV-30)  
DV-46DVA-GK  
FLEX3-30  
LINK-DV4-30B  
(LINK-DV4-30)  
Figure 14.2 Direct Vent Flex Liner Kits  
FLEX3-CNCT  
Direct Vent Flex Liner Accessory Kits (see Figure 14.3)  
Flash-Damp: Zero clearance damper flashing kit for use  
with the LINK-DV-30B or LINK-DV4-30B liner kits.  
Î
Figure 14.3 Direct Vent Flex Liner Accessory Kits  
LINK-ZC-ADP: Zero clearance chimney adapter  
ÎDV-46DVA-GK: Adapter kit (colinear to coaxial 3 inches  
included in above kits). It is permissible to use DV-46DVA-  
GK to connect collinear flex vent to SL-D vent pipe to  
extend the run.  
FLEX3-30: One 3 inch flexible liner expands to 30 feet.  
FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner,  
one connector per kit.  
40  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D. Contact Information  
R
Quadra-Fire, a brand of Hearth & Home Technologies Inc.  
7571 215th Street West, Lakeville, MN 55044  
Please contact your Quadra-Fire dealer with any questions or concerns.  
For the location of your nearest Quadra-Fire dealer,  
please visit www.quadrafire.com.  
- NOTES -  
________________________________________________________________________________  
________________________________________________________________________________  
________________________________________________________________________________  
________________________________________________________________________________  
________________________________________________________________________________  
________________________________________________________________________________  
________________________________________________________________________________  
________________________________________________________________________________  
________________________________________________________________________________  
NOTICE  
DO NOT DISCARD THIS MANUAL  
• Important operating  
and maintenance  
instructions included.  
• Read, understand and follow  
these instructions for safe  
installation and operation.  
• Leave this manual with  
party responsible for use  
and operation.  
This product may be covered by one or more of the following patents: (United States) 5328356, 5601073, 5613487,  
5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712,  
6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending.  
2000-945  
Printed in U.S.A. - Copyright 2010  
46  
Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Stereo Amplifier XL 400 User Guide
RCA Camcorder EZ2120 User Guide
RCA MP3 Player TH161 Series User Guide
RIDGID Planer TP1300LS User Guide
Rosen Entertainment Systems DVD Player AV770 User Guide
Rotel Cassette Player RD 955AX User Guide
Samsung Camcorder ES80 User Guide
Samsung TV DVD Combo DVD P147 User Guide
Sanyo Vacuum Cleaner SC A114 User Guide
Sarlo Trimmer CS 16 User Guide