ESPAÑOL: PÁGINA 13
FRANÇAISE : PAGE 25
Instruction
manual
FINISH NAILER
MODEL FN250A
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
To learn more about Porter-Cable
visit our website at:
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No._______________________________________
Copyright © 2003 Porter-Cable Corporation
Part No. 903096 - 05-09-03
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY GUIDELINES / DEFINITIONS
This manual contains information that is important for you to know and under-
stand. This information relates to protecting YOUR SAFETY and PREVENTING
EQUIPMENT PROBLEMS. To help you recognize this information, we use the
symbols below. Please read the manual and pay attention to these sections.
indicates an imminently hazardous situation which, if not avoided,
will result in death or serious injury.
indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury.
used without the safety alert symbol indicates potentially
hazardous situation which, if not avoided, may result in property
damage.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
Improper operation or maintenance of this product could
result in serious injury and property damage. Read and understand all
warnings and operating instructions before using this tool. When using
pneumatic tools, basic safety precautions should always be followed to
reduce the risk of personal injury.
READ AND FOLLOW ALL INSTRUCTIONS.
There are certain applications for which this tool was designed. Porter-Cable
strongly recommends that this tool NOT be modified and/or used for any
application other than for which it was designed. If you have any questions
relative to its application DO NOT use the tool until you have written Porter-
Cable and we have advised you.
Technical Service Manager
Porter-Cable Corporation
4825 Highway 45 North
Jackson, TN 38305
Download from Www.Somanuals.com. All Manuals Search And Download.
3
GENERAL SAFETY RULES
1. Read and understand tool labels and
Fig. 1
manual. Failure to follow warnings could
result in DEATH or SERIOUS INJURY. Fig. 1.
2. Operator and others in work area MUST
wear safety glasses with side shields.
These safety glasses must conform to ANSI
Z87.1 requirements (approved glasses have
“Z87” printed or stamped on them). Fig. 2.
Fig. 2
3.
Keep fingers AWAY from
trigger when not driving fasteners to
avoid accidental firing.
Fig. 3
4. Choice of triggering method is
important. Check manual for triggering
options. See “Using the Tool with
Selectable Triggering Options” section of
this manual.
5. Never point tool at yourself or others
in work area. Fig. 3
Fig. 4
6.
Never use oxygen or
other bottled gasses. Explosion may
occur. Never use combustible gases or any
other reactive gas as a power source for
this tool: explosion and serious personal
injury could result. Fig. 3 & Fig. 4.
Fig. 5
7. Wear ear protection to safe-guard
against possible hearing loss. Ear
protection equipment must conform to ANSI
S3.19 requirements. Fig. 5.
Fig. 6
8. Use clean, dry, regulated, com-
pressed air at 70 to 120 PSI, (4.8 to 8.3
BAR). Fig. 6.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
9. Do not connect tool to pressure which
potentially exceeds 200 PSI (13.7 BAR).
10. Only use air hose that is rated for a
maximum working pressure of at least 150
PSI (10.3 BAR) or 150% of the maximum
system pressure, which ever is greater.
11. Connect tool to air supply hose with a
coupling that automatically removes all
pressure from the tool when the coupling is
disconnected. Fig. 7.
12. Disconnect tool from air supply hose
before doing tool maintenance, clearing a
jammed fastener, leaving work area, moving
tool to another location, or handing the tool to
another person. Fig. 7.
Fig. 7
Fig. 8
13. Never use a tool that is leaking air, has
missing or damaged parts, or requires repair.
Make sure all screws and caps are securely
tightened. Fig. 8.
14. Never use tool if safety, trigger or
springs are inoperable, missing or damaged.
Do not alter or remove safety, trigger, or
springs. Make daily inspections for free
movement of trigger and safety mechanism.
Fig. 8.
Fig. 9
15. Do not use tool without safety
warning label. If label is missing, damaged
or unreadable, contact your Porter-Cable
Service Center for a replacement. Fig. 9.
16. Only use parts, fasteners and
accessories approved by Porter-Cable.
17. Connect tool to air supply before
loading fasteners, to prevent a fastener from
being fired during connection. The tool
driving mechanism may cycle when tool is
connected to the air supply. Fig. 10.
Fig. 10
18. Always assume the tool contains
fasteners. No horseplay. Respect the tool as
a working implement. Fig. 11.
Fig. 11
19. Operator and bystanders wear hard hat
to safeguard against possible injuries. Fig.
12.
20. Do not load fasteners with trigger or
safety depressed, to prevent unintentional
firing of a fastener. Fig. 13
Fig. 12
Fig. 13
Download from Www.Somanuals.com. All Manuals Search And Download.
5
21. Remove finger from trigger when not
driving fasteners. Never carry tool with finger
on trigger. In “Contact Actuation Mode” tool
will fire a fastener if safety is bumped while
trigger is depressed. Fig. 14.
Fig. 14
22. Do not overreach. Keep proper footing
and balance at all times when using or
handling the tool.
23. Fire fasteners into work surface only:
never into materials too hard to penetrate.
Fig. 15.
Fig. 15
24. Grip tool firmly to maintain control
while allowing tool to recoil away from
work surface as fastener is driven. In
“Contact Actuation Mode” if safety element
is allowed to recontact work surface before
trigger is released an unwanted fastener will
be fired.
Fig. 16
25. Do not drive fasteners on top of other
fasteners, or with the tool at too steep an
angle: the fasteners can ricochet causing
personal injury. Fig. 15.
26. Do not drive fasteners close to the
edge of the workpiece. The workpiece is
likely to split allowing the fastener to fly free
or ricochet causing personal injury. Fig. 16.
Fig. 17
27. FOR TOOLS SET FOR CONTACT
ACTUATION MODE, Do not use on
scaffoldings or ladders or for tasks in
which changing location involves the use of
scaffoldings, stairs, ladders, and the like. Do
not use for specific tasks such as closing
boxes or crates or fitting transportation
safety systems on vehicles and wagons.
Fig. 17
TECHNICAL SPECIFICATIONS
Noise level . . . . . . . . . . . . . . . . . .
Typical Mean
A - Weighted sound impulse . . .
power level . . . . . . 95.1 dBA
P - Emission sound pressure
pressure level . . . . 86.3 dBA
effective Acceleration . . . 3.91 m/s2
6
Download from Www.Somanuals.com. All Manuals Search And Download.
EMPLOYER’S RESPONSIBILITIES
Employer must enforce compliance with the safety warnings
and all other instructions contained in this manual.
Keep this manual available for use by all people assigned to use this tool.
For personal safety and proper operation of this tool, read and understand
tool labels and manual. Failure to follow warnings could result in DEATH or
SERIOUS INJURY. Read and follow all of these instructions carefully.
FUNCTIONAL DESCRIPTION
FOREWORD
Porter-Cable Model FN250A is a heavy duty pneumatic finish nailer. It is
3
designed to install 16 ga. finish nails of various lengths (from /4" to 2-1/2"
long).
Fastener Guide (furnished with FN250A) must be
used when driving fasteners that are less than 1-1/2" long (see
FASTENER GUIDE Section of this manual). Use approved Porter-
Cable fasteners only.
POWER SOURCE
This tool is designed to operate on clean, dry, compressed air at regulated
pressures between 70 and 120 PSI (Pounds per Square Inch)(4.8 to 8.3 BAR)
.
The preferred system would include a filter, a pressure regulator, and an
automatic oiler located as close to the tool as possible, within 15 ft/4.6 m is
ideal.
All compressed air contains moisture and other contaminates that are
detrimental to internal components of the tool. An air line filter will remove
most of these contaminates and significantly prolong the life of the tool. If an
in-line oiler is not available: place five or six drops of Porter-Cable Air Tool Oil
into the tool’s air inlet at the beginning of each workday.
1
3
The tool is equipped with a
/
4" male “quick connector”. A /8" male “quick
connector” is available from Porter-Cable and may be used in situations where
1
3
a
/
4" supply line is not available. A /8" supply line (and fittings) are required for
maximum tool performance. The tool must always be connected to the air
supply with a coupling such that all pressure is removed from the tool when the
coupling is disconnected.
All air line components (hoses, connectors, filters, regulators,
etc.) must have a minimum working pressure rating of at least 150 PSI
(10.3 BAR) or 150% of maximum system potential, whichever is greater
.
Do not connect tool to pressure which potentially exceeds 200 PSI
(13.7 BAR).
Only connect tool to air supply hose with a coupling that
automatically removes all pressure from the tool when the coupling
is disconnected.
Disconnect tool from air supply before performing maintenance,
clearing a jammed fastener, leaving work area, moving tool to
another location, or handing the tool to another person.
PREPARING THE TOOL
1. After reading and understanding this entire manual, connect tool to
air supply (Fig. 18).
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Never point tool at yourself or others.
Always connect tool to air supply before loading fasteners (Fig. 18).
Do not load fasteners with trigger or safety depressed.
Only use approved Porter-Cable fasteners.
Operator and others in work area MUST wear safety glasses with side
shields. Always wear ANSI Z87.1 approved safety glasses, and ANSI
S3.19 approved hearing protection when preparing or operating the
tool.
Never use a tool that is leaking air, has missing or damaged parts, or
requires repair.
2. Pull follower (A) Fig. 19, all the way to the rear, until it latches.
3. Insert a strip of approved fasteners, see Fig. 20. Orient fasteners with
points down. Slide fasteners forward to the front of the magazine. The
magazine will hold two full strips of fasteners.
4. Depress follower release lever (A) Fig. 21, allowing the follower to slide
forward against the fasteners.
Fig. 18
Fig. 19
A
Fig. 20
Fig. 21
A
5. Adjust directional exhaust deflector
(A) Fig. 22, so that the exhaust air
blast will be directed away from the
operator. The exhaust deflector
provides seven detented positions for
directing the exhaust blast away from
the operator. Grasp the deflector and
rotate it to the desired position for the
current application.
Fig. 22
A
8
Download from Www.Somanuals.com. All Manuals Search And Download.
B
B
A
A
Fig. 24
Fig. 25
Fig. 23
FASTENER GUIDE
A Fastener Guide (A) Fig. 23 and 24,
is factory installed on Model
FN250A. The Guide is held in place
with a bolt and nut (B) Fig. 23 and
24. The Fastener Guide must be
used whenever driving fasteners that
are less than 11/2" long. The Fastener
Guide must be removed when
driving fasteners that are 11/2" or
more in length. When not in use, the
fastener guide may be stored by
attaching it to the rear bracket as
shown in Fig. 25.
A
OPERATING INSTRUCTIONS
USING THE TOOL
Complete all steps of PREPARING THE TOOL before using the tool.
To fire, grip tool firmly, position nose of tool onto work surface, push forward
on tool to depress safety, and squeeze trigger to fire a fastener. This “trigger
fire” method provides the most accurate fastener placement. This tool is
shipped from the factory with a “restrictive fire trigger” that only allows the
tool to be fired this way and is less likely to fire an unwanted fastener.
An alternate “bottom fire trigger” is available. The “bottom fire” trigger allows
the tool to be fired in two different ways.
1. The tool can be fired using the “trigger fire” method described above.
OR
2. Grip tool firmly, depress and hold trigger while pushing the tool firmly
against work surface. The tool will fire a fastener each time the safety is
depressed. This method is known as “bottom fire” and allows very fast
repetitive fastener placement.
The “bottom fire trigger” is available free-of-charge by calling 1-800-321-9443
in the United States and Canada or 001-901-660-9374 outside the United
States and Canada, and providing tool model and serial number. For
identification purposes: the Bottom Fire Trigger is black and the Restrictive
Fire Trigger is red.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Remove finger from trigger when not driving fasteners.
Never carry tool with finger on trigger: tool will fire a fastener if
safety is bumped.
Keep fingers AWAY from trigger when not driving
fasteners to avoid accidental firing. Never carry tool with finger on
trigger. In “Contact Actuation Mode” tool will fire a fastener if safety
is bumped while trigger is depressed.
Never point tool at yourself or others.
Never attempt to drive a fastener into material that is too hard, or at
too steep an angle, or near the edge of the workpiece. The
fastener can ricochet causing personal injury.
Disconnect tool from air supply before performing
maintenance, clearing a jammed fastener, leaving work
area, moving tool to another location, or handing the tool
to another person.
Clean and inspect tool daily. Carefully check for proper
operation of trigger and safety mechanism. Do Not use the tool unless
both the trigger and the safety mechanism are functional, or if the tool is
leaking air or needs any other repair.
The depth to which a fastener is driven is controlled by the depth adjustment
knob (A) Fig. 26. The depth of drive is factory adjusted to a nominal setting.
Test fire a fastener and check depth. If a change is desired, rotate the
1
adjustment knob (A) Fig. 26: the adjustment knob has detents every /4 turn.
Rotate the knob clockwise (see Fig. 26), to increase the depth of drive, rotate
the knob counterclockwise to
Fig. 26
decrease the depth of drive. Test fire
another fastener and check depth.
Repeat as necessary to achieve
desired results. The amount of air
pressure required will vary depending
on the size of the fastener and the
material being fastened. Experiment
with the air pressure setting to
determine the lowest setting that will
consistently perform the job at hand.
A
Air pressure in excess of that
required can cause premature wear
and/or damage to the tool.
CLEARING A JAMMED FASTENER
Disconnect tool from air supply.
2. Open magazine and remove any remaining fasteners.
3. Depress the quick release latch lever (A) Fig. 27, and hinge the fastener
guide plate open.
4. Remove the jammed fastener (see Fig. 28).
5. Close the fastener guide plate and secure with the quick release latch.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
A
Fig. 28
Fig. 27
MAINTENANCE
CLEAN AND INSPECT DAILY
Disconnect tool from air supply before cleaning and
inspection. Correct all problems before placing the tool back in use.
Wipe tool clean and inspect for wear or damage. Use non-flammable
cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK
tool with cleaning solutions. Such solutions can damage internal parts.
Inspect trigger and safety mechanism to assure system is complete and
functional: no loose or missing parts, no binding or sticking parts.
Keep all screws tight. Loose screws can cause personal injury or damage
tool.
If tool is used without an in-line oiler: place 5 or 6 drops of Porter-Cable Air
Tool Oil into the air inlet of the tool at the beginning of each workday.
SERVICE AND REPAIRS
All quality tools will eventually require servicing or replacement of parts due
to wear from normal use. These operations should ONLY be performed by
either an AUTHORIZED PORTER-CABLE SERVICE STATION or a PORTER-
CABLE•DELTA FACTORY SERVICE CENTER. All repairs made by these
agencies are fully guaranteed against defective material and workmanship.
We cannot guarantee repairs made or attempted by anyone other than these
agencies.
Should you have any questions about your tool, feel free to write us at any
time. In any communications, please give all information shown on the
nameplate of your tool (model number, type, serial number, etc.).
TROUBLESHOOTING
Disconnect tool from air supply before performing any Service
Procedure.
SYMPTOM
PROBLEMS
SOLUTIONS
1. Air leak near top of
tool or in trigger area.
Loose screws.
Worn or damaged
o-rings or seals.
Tighten screws.
Install Overhaul Kit.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Tool does nothing or
operates sluggishly.
Inadequate air supply.
Inadequate lubrication.
Worn or damaged
o-rings or seals.
Verify adequate air supply.
Put 5 or 6 drops of oil into air inlet.
Install Overhaul Kit.
3. Air leak near bottom
of tool.
Loose screws.
Worn or damaged
o-rings or bumper.
Tighten screws.
Install Overhaul Kit.
4. Tool jams frequently.
Incorrect fasteners.
Verify approved fasteners of
correct size.
Damaged fasteners.
Magazine or nose
screws loose.
Replace w/undamaged fasteners.
Tighten screws.
Magazine is dirty.
Clean magazine.
Driver is worn or damaged. Install “DRIVER” Maintenance Kit.
5. Other.
Contact a Porter-Cable
Service Facility.
ACCESSORIES
A complete line of accessories is available from your Porter-Cable • Delta
Supplier, Porter-Cable • Delta Factory Service Centers, and Porter-Cable
Authorized Service Stations. Please visit our Web Site www.porter-cable.com
for a catalog or for the name of your nearest supplier.
Since accessories, other than those offered by Porter-
Cable • Delta, have not been tested with this product, use of such
accessories could be hazardous. For safest operation, only Porter-Cable
• Delta recommended accessories should be used with this product.
PORTER-CABLE LIMITED
ONE YEAR WARRANTY
Porter-Cable warrants its nailing and stapling tools for a period of one year from the date of original
purchase. We will repair or replace at our option, any part or parts of the product and accessories
covered under this warranty which, after examination, proves to be defective in workmanship or
material during the warranty period. For repair or replacement return the complete tool or accessory,
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.
Proof of purchase may be required. This warranty does not apply to O-rings and Driver Blades or to
repair or replacement required due to misuse, abuse, normal wear and tear or repairs attempted or
made by other than our Service Centers or Authorized Service Stations.
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE
OF PURCHASE.
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,
4825 Highway 45 North, Jackson, Tennessee 38305; Attention: Product Service. THE FOREGOING
OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRANTY
AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other legal rights which vary
from state to state.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
PORTER-CABLE • DELTA SERVICE CENTERS
(CENTROS DE SERVICIO DE PORTER-CABLE • DELTA)
(CENTRE DE SERVICE PORTER-CABLE • DELTA)
Parts and Repair Service for Porter-Cable
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable
(Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien)
•
Delta Power Tools are Available at These Locations
•
Delta)
Cleveland 44125
8001 Sweet Valley Drive
Unit #19
Phone: (216) 447-9030
Fax: (216) 447-3097
ARIZONA
MINNESOTA
Minneapolis 55429
5522 Lakeland Avenue North
Phone: (763) 561-9080
Fax: (763) 561-0653
ILLINOIS
Tempe 85282 (Phoenix)
2400 West Southern Avenue
Suite 105
Phone: (602) 437-1200
Fax: (602) 437-2200
Addison 60101 (Chicago)
400 South Rohlwing Rd.
Phone: (630) 424-8805
Fax: (630) 424-8895
OREGON
Portland 97230
4916 NE 122 nd Ave.
Phone: (503) 252-0107
Fax: (503) 252-2123
MISSOURI
Woodridge 60517 (Chicago)
2033 West 75th Street
Phone: (630) 910-9200
Fax: (630) 910-0360
CALIFORNIA
North Kansas City 64116
1141 Swift Avenue
Phone: (816) 221-2070
Fax: (816) 221-2897
Ontario 91761 (Los Angeles)
3949A East Guasti Road
Phone: (909) 390-5555
Fax: (909) 390-5554
San Leandro 94577 (Oakland)
3039 Teagarden Street
Phone: (510) 357-9762
Fax: (510) 357-7939
MARYLAND
St. Louis 63119
Elkridge 21075 (Baltimore)
7397-102 Washington Blvd.
Phone: (410) 799-9394
Fax: (410) 799-9398
7574 Watson Road
Phone: (314) 968-8950
Fax: (314) 968-2790
PENNSYLVANIA
Willow Grove 19090
520 North York Road
Phone: (215) 658-1430
Fax: (215) 658-1433
NEW YORK
MASSACHUSETTS
Braintree 02185 (Boston)
719 Granite Street
Phone: (781) 848-9810
Fax: (781) 848-6759
COLORADO
Flushing 11365-1595 (N.Y.C.)
175-25 Horace Harding Expwy.
Phone: (718) 225-2040
Fax: (718) 423-9619
Arvada 80003 (Denver)
8175 Sheridan Blvd., Unit S
Phone: (303) 487-1809
Fax: (303) 487-1868
TEXAS
Carrollton 75006 (Dallas)
1300 Interstate 35 N, Suite 112
Phone: (972) 446-2996
Fax: (972) 446-8157
NORTH CAROLINA
Charlotte 28270
9129 Monroe Road, Suite 115
Phone: (704) 841-1176
Fax: (704) 708-4625
Franklin 02038 (Boston)
Franklin Industrial Park
101E Constitution Blvd.
Phone: (508) 520-8802
Fax: (508) 528-8089
FLORIDA
Davie 33314 (Miami)
4343 South State Rd. 7 (441)
Unit #107
Phone: (954) 321-6635
Fax: (954) 321-6638
Tampa 33609
4538 W. Kennedy Boulevard
Phone: (813) 877-9585
Fax: (813) 289-7948
Houston 77055
West 10 Business Center
1008 Wirt Road, Suite 120
Phone: (713) 682-0334
Fax: (713) 682-4867
OHIO
MICHIGAN
Columbus 43214
4560 Indianola Avenue
Phone: (614) 263-0929
Fax: (614) 263-1238
Madison Heights 48071 (Detroit)
30475 Stephenson Highway
Phone: (248) 597-5000
Fax: (248) 597-5004
WASHINGTON
Auburn 98001(Seattle)
3320 West Valley HWY, North
Building D, Suite 111
Phone: (253) 333-8353
Fax: (253) 333-9613
GEORGIA
Forest Park 30297 (Atlanta)
5442 Frontage Road,
Suite 112
Phone: (404) 608-0006
Fax: (404) 608-1123
Authorized Service Stations are located in many large cities. Telephone 800-487-8665 or 731-541-6042 for assistance locating one. Parts and
accessories for Porter-Cable Delta products should be obtained by contacting any Porter-Cable Delta Distributor, Authorized Service
Center, or Porter-Cable Delta Factory Service Center. If you do not have access to any of these, call 888-848-5175 and you will be directed to
the nearest Porter-Cable Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están ubicadas en muchas grandes ciudades.
Llame al 800-487-8665 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las piezas y los accesorios para los productos Porter-
Cable Delta deben obtenerse poniéndose en contacto con cualquier distribuidor Porter-Cable Delta, Centro de Servicio Autorizado o Centro
de Servicio de Fábrica Porter-Cable Delta. Si no tiene acceso a ninguna de estas opciones, llame al 888-848-5175 y le dirigirán al Centro de
Servicio de Fábrica Porter-Cable Delta más cercano. Des centres de service agréés sont situés dans beaucoup de grandes villes. Appelez au
800-487-8665 ou au 731-541-6042 pour obtenir de l’aide pour en repérer un. Pour obtenir des pièces et accessoires pour les produits Porter-
•
•
•
•
•
•
•
•
Cable
•
Delta, s’adresser à tout distributeur Porter-Cable
•
Delta, centre de service agréé ou centre de service d’usine Porter-Cable
•
Delta. Si
Delta le
vous n’avez accès à aucun de ces centres, appeler le 888-848-5175 et on vous dirigera vers le centre de service d’usine Porter-Cable
•
plus proche.
CANADIAN PORTER-CABLE • DELTA SERVICE CENTERS
QUÉBEC
ALBERTA
MANITOBA
1515 Ave.
Bay 6, 2520-23rd St. N.E.
Calgary, Alberta
T2E 8L2
1699 Dublin Avenue
Winnipeg, Manitoba
R3H 0H2
St-Jean Baptiste,
Québec, Québec
G2E 5E2
Phone: (418) 877-7112
Fax: (418) 877-7123
Phone: (403) 735-6166
Fax: (403) 735-6144
Phone: (204) 633-9259
Fax: (204) 632-1976
BRITISH COLUMBIA
8520 Baxter Place
Burnaby, B.C.
V5A 4T8
Phone: (604) 420-0102
Fax: (604) 420-3522
ONTARIO
1447, Begin
St-Laurent, (Montréal), Québec
H4R 1V8
Phone: (514) 336-8772
Fax: (514) 336-3505
505 Southgate Drive
Guelph, Ontario
N1H 6M7
Phone: (519) 836-2840
Fax: (519) 767-4131
The following are trademarks of PORTER-CABLE
•
DELTA (Las siguientes son marcas registradas de PORTER-CABLE
•
DELTA S.A.) (Les
marques suivantes sont des marques de fabriquant de la PORTER-CABLE
•
DELTA): Auto-Set®, BAMMER®, B.O.S.S.®, Builder’s Saw®,
Contractor’s Saw®, Contractor’s Saw II™, Delta®, DELTACRAFT®, DELTAGRAM™, Delta Series 2000™, DURATRONIC™, Emc²™, FLEX®,
Flying Chips™, FRAME SAW®, Homecraft®, INNOVATION THAT WORKS®, Jet-Lock®, JETSTREAM®, ‘kickstand®, LASERLOC®, MICRO-SET®,
Micro-Set®, MIDI LATHE®, MORTEN™, NETWORK™, OMNIJIG®, POCKET CUTTER®, PORTA-BAND®, PORTA-PLANE®, PORTER-
CABLE®&(design), PORTER-CABLE®PROFESSIONAL POWER TOOLS, Posi-Matic®, Q-3®&(design), QUICKSAND®&(design), QUICKSET™,
QUICKSET II®, QUICKSET PLUS™, RIPTIDE™&(design), SAFE GUARD II®, SAFE-LOC®, Sanding Center®, SANDTRAP®&(design), SAW BOSS®,
Sawbuck™, Sidekick®, SPEED-BLOC®, SPEEDMATIC®, SPEEDTRONIC®, STAIR EASE®, The American Woodshop®&(design), The Lumber
Company®&(design), THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, THIN-LINE™, TIGER®, TIGER CUB®, TIGER SAW®,
TORQBUSTER®, TORQ-BUSTER®, TRU-MATCH™, TWIN-LITE®, UNIGUARD®, Unifence®, UNIFEEDER™, Unihead®, Uniplane™, Unirip®,
Unisaw®, Univise®, Versa-Feeder®, VERSA-PLANE® , WHISPER SERIES®, WOODWORKER’S CHOICE™.
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other
countries. Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y
también pueden estar registradas en otros países. Marques déposées, indiquées par la lettre ™ et ®, sont déposées au Bureau des brevets
d’invention et marques déposées aux Etats-Unis et pourraient être déposées aux autres pays.
Download from Www.Somanuals.com. All Manuals Search A
P
n
r
d
int
D
edowin
n
U
lo.S
a
.
d
.
PC-0303-151
|