Patton electronic Network Card 2156 User Manual

USER  
MANUAL  
MODELS 2156 & 2157  
CopperLink Ethernet  
Extenders  
Part# 07M2156_2157  
Doc# 032131U Rev. A  
Revised 2/4/03  
SALES OFFICE  
(301) 975-1000  
TECHNICAL SUPPORT  
(301) 975-1007  
An ISO-9001Certified  
Company  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.0 WARRANTY INFORMATION  
Patton Electronics warrants all Model 2156 or 2157 components to be  
free from defects, and will—at our option—repair or replace the product  
should it fail within one year from the first date of the shipment.  
This warranty is limited to defects in workmanship or materials, and does  
not cover customer damage, abuse or unauthorized modification. If this  
product fails or does not performs as warranted, your sole recourse shall  
be repair or replacement as described above. Under no condition shall  
Patton Electronics be liable for any damages incurred by the use of this  
product.These damages include, but are not limited to, the following: lost  
profits, lost savings and incidental or consequential damages arising  
from the use of or inability to use this product. Patton Electronics spe-  
cifically disclaims all other warranties, expressed or implied, and the  
installation or use of this product shall be deemed an acceptance of  
these terms by the user.  
Note Conformity documents of all Patton products can be viewed  
online at www.patton.com under the appropriate product page.  
1.1 RADIO AND TV INTERFERENCE  
The Model 2156 or 2157 generate and use radio frequency energy, and  
if not installed and used properly—that is, in strict accordance with the  
manufacturer’s instructions—may cause interference to radio and televi-  
sion reception. The Models 2156 and 2157 have been tested and found  
to comply with the limits for a Class A computing device in accordance  
with specifications in Subpart B of Part 15 of FCC rules, which are  
designed to provide reasonable protection from such interference in a  
commercial installation. However, there is no guarantee that interference  
will not occur in a particular installation. If the Model 2156 or 2157 does  
cause interference to radio or television reception, which can be deter-  
mined by disconnecting the unit, the user is encouraged to try to correct  
the interference by one or more of the following measures: moving the  
computing equipment away from the receiver, re-orienting the receiving  
antenna and/or plugging the receiving equipment into a different AC out-  
let (such that the computing equipment and receiver are on different  
branches).  
1.2 CE NOTICE  
The CE symbol on your Patton Electronics equipment indicates that it is  
in compliance with the Electromagnetic Compatibility (EMC) directive  
and the Low Voltage Directive (LVD) of the European Union (EU). A Cer-  
tificate of Compliance is available by contacting Technical Support.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
1.3 FCC PART 68  
The Models 2156 and 2157 are not intended to be con-  
nected to the public telephone network.  
Caution  
1. You are required to request service from the telephone company before  
you connect the Model 2156 or 2157 to a network. When you request  
service, you must provide the telephone company with the following  
data.  
The required Universal Service Order code (USOC) jack: RJ-11C  
The make, model number, Ringer Equivalence Number (REN),  
and FCC Registration number of the Model 2156 or 2157.  
The REN helps you determine the number of devices you can con-  
nect to your telephone line and still have all of those devices ring  
when your number is called. In most, but not all, areas, the sum of  
the RENs of all devices should not exceed five (5.0).To be certain of  
the number of devices you can connect to your line, you should call  
your local telephone company to determine the maximum REN.  
The Facility Interface Code: 02LS2  
The Service Order Code(s) (SOC): 9.0F  
REN No.: 0.2  
2. Your telephone company may make changes to its facilities, equip-  
ment, operations, or procedures that could affect the proper func-  
tioning of your equipment. The telephone company will notify in  
advance of such changes to give you an opportunity to maintain  
uninterrupted telephone service.  
3. If your Model 2156 or 2157 causes harm to the telephone network,  
the telephone company may temporarily discontinue your service. If  
possible, they will notify you in advance, but if advance notice is not  
practical, you will be notified as soon as possible and will be  
informed of your right to file a complaint with the FCC.  
4. If you experience trouble with the Model 2156 or 2157, contact Pat-  
ton Electronics Company for service or repairs. Repairs should be  
performed only by Patton Electronics Co.  
5. You are required to notify the telephone company when you discon-  
nect the Model 2156 or 2157 from the network.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1.4 INDUSTRY CANADA NOTICE  
NOTICE: This equipment meets the applicable Industry Canada Termi-  
nal Equipment Technical Specifications.This is confirmed by the registra-  
tion number.The abbreviation IC, before the registration number signifies  
that registration was performed based on a Declaration of conformity  
indicating that Industry Canada technical specifications were met. It does  
not imply that Industry Canada approved the equipment.  
1.5 SERVICE  
All warranty and non-warranty repairs must be returned freight prepaid  
and insured to Patton Electronics. All returns must have a Return Materi-  
als Authorization number on the outside of the shipping container. This  
number may be obtained from Patton Electronics Technical Services at:  
Telephone: +1 (301) 975-1007  
Technical support is available from 8 AM to 5 PM EST (8:00 to 17:00  
UTC-5), Monday through Friday.  
Note Packages received without an RMA number will not be  
accepted.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.0 GENERAL INFORMATION  
Thank you purchasing this Patton Electronics product. This product has  
been thoroughly inspected and tested and is warranted for one year for  
parts and labor. If questions arise while installing or using this product,  
contact Technical Support at +1 (301) 975-1007.  
2.1 FEATURES  
• Easy-to-install Ethernet Extenders—no configuration required  
• Auto-rate adaption ensures the highest rate possible for each exten-  
sion distance  
• Data rates to 2.3 Mbps (for Model 2156) and 4.6 Mbps (for Model 2157)  
• Auto-sensing 10/100Base-T  
• Extends network connections up to 30,000 ft (9,144 m) over 2-wire 24-  
AWG unconditioned lines (see Appendix A on page 15)  
Transparent operation to higher level protocols such as TCP/IP, DEC-  
net, NETBIOS, IPX, etc.  
• Compatible with 802.1Q VLAN  
• LED indicators for Power; Ethernet Link, 100Base-T Operation, Transmit,  
Receive;WAN Link, Transmit, Receive  
• Made in the USA  
2.2 DESCRIPTION  
The Patton Electronics CopperLink Ethernet Extenders provide high-  
speed LAN connections between peered Ethernet LANs, remote PCs, or  
any other network enabled 10/100Base-T device.  
Operating in pairs, a Model 2156 or 2157 can automatically forward LAN  
broadcasts, multicasts, and frames across a 2-wire voice-grade twisted-  
pair link. The data is passed transparently (unmodified) through the Ether-  
net Extenders. They automatically add and delete MAC addresses, only  
passing packets across the CopperLink line that are meant for the remote  
peered LAN.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Figure 1. Typical application  
The 2157/L and 2157/R work together to create a transparent extension  
between two peered Ethernet LANs. Figure 1 shows a typical point-to-  
point application.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
can be installed quickly. Installation consists of the following:  
• Connect the line interface between the units (refer to section 3.1,  
“Connecting the Twisted-Pair Line Interface” on page 8)  
Note See Figure 2 for the rear-panel connectors locations.  
• Connect the Ethernet interface (refer to section 3.2, “Line Interface—  
Connecting the 10/100Base-T Ethernet Interface” on page 9).  
• Connect the power plug (refer to section 3.3, “Connecting Power” on  
page 11).  
Figure 2. CopperLink Ethernet Extender rear panel  
3.1 CONNECTING THE TWISTED-PAIR LINE INTERFACE  
The Models 2156 and 2157 support communication between two peer  
Ethernet LAN sites over a distance greater than 30,000 ft (9,144 m) over  
24 AWG (0.5 mm) twisted-pair wire.  
Note The Models 2156 and 2157 use an auto-rate adaption feature to  
provide the fastest data rate possible over the wire and distance  
of each Ethernet extension. The actual distance and rate  
achieved for Ethernet extension may vary depending on the  
environment and type/gauge of the wire used.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Follow the steps below to connect the CopperLink interfaces.  
Note The Model 2156 or 2157 units work in pairs. One of the units  
must be a Model 2156/L (local) or 2157/L, and the other unit  
must be a Model 2156/R (remote) or 2157/R.  
1. To function properly, the two Ethernet Extenders must be connected  
together using twisted-pair, unconditioned, dry, metal wire, between  
19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through  
signal equalization equipment are not acceptable.  
2. The Models 2156 and 2157 are equipped with an RJ-11 interface.  
The CopperLink interfaces are a two-wire interface. Observe the sig-  
nal/pin relationships on the CopperLink interface jack.  
The RJ-11 connector on the CopperLink Ethernet Extender’s twisted pair  
interface is polarity insensitive and is wired for a two-wire interface. The  
signal/pin relationship is shown in Figure 3.  
Figure 3. CopperLink Ethernet Extender (RJ-11) twisted pair line interface.  
3.2 LINE INTERFACE—CONNECTING THE 10/100BASE-T  
ETHERNET INTERFACE  
The shielded RJ-45 port labeled Ethernet is the 10/100Base-T interface.  
This port is designed to connect directly to a 10/100Base-T network.  
Figure 4 shows the signal/pin relationships on this interface.You may  
connect this port to another Ethernet device via a Type 4 or Type 5 cable  
that is up to 328 ft (100 m) long.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 4. CopperLink Ethernet Extender 10/100Base-T RJ-45 Connector Pinout.  
Connecting the 10/100Base-T Ethernet Port to a Hub or PC  
The Models 2156 and 2157 are equipped with an MDI-X switch that  
enables connections to a hub (DCE) or PC (DTE) interface, thereby  
elimininating confusion over whether a straight-through or crossover  
cable is needed.  
When using a straight-through cable for connecting to a hub, the MDI-X  
switch should be in its released (DCE mode) position (see Figure 5).  
When connecting to a PC, the MDI-X switch should be pushed in to  
engage the crossover function so you won’t have to use a crossover cable  
DTE mode  
MDI-X  
switch  
DCE mode  
Figure 5. MDI-X switch positions  
Note If you have difficulty achieving a working connection between  
the CopperLink Ethernet Extender’s Ethernet port and the hub  
or PC, change the position of the MDI-X switch and try again.  
In its released position, the MDI-X switch enables straight-through con-  
nections (see Figure 6) or in its inserted position the MDI-X switch per-  
forms the crossover function (see Figure 7 on page 11).  
2157 10/100Base-T Port  
RJ-45 Pin No.  
10/100Base-T Hub  
RJ-45 Pin No.  
1 (TX+)--------------------------------------------------1 (RX+)  
2 (TX-)---------------------------------------------------2 (RX-)  
3 (RX+)--------------------------------------------------3 (TX+)  
6 (RX-)---------------------------------------------------6 (TX-)  
Figure 6. Wiring diagram for connecting the CopperLink Ethernet Extender to a  
10/100Base-T hub (MDI-X switch released)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2157 10/100Base-T Port  
RJ-45 Pin No.  
10/100Base-T DTE  
RJ-45 Pin No.  
1 (TX+)  
2 (TX-)  
1 (TX+)  
2 (TX-)  
3 (RX+)  
6 (RX-)  
3 (RX+)  
6 (RX-)  
Figure 7. MDI-X switch pressed in performs 10/100Base-T crossover function  
3.3 CONNECTING POWER  
An external AC or DC power supply is available separately. This connec-  
tion is made via the barrel jack on the rear panel of the Models 2156 and  
2157. No configuration is necessary for the power supply (See  
Appendix B on page 18 for domestic and international power supply and  
cord options).  
3.4 POWER INPUT CONNECTOR  
The CopperLink Ethernet Extender comes with an AC or DC power supply.  
• The supplies connection to the CopperLink Ethernet Extender is a  
2.5 mm barrel receptacle with the center conductor positive (see  
Figure 6).  
Figure 8. Power connection barrel receptacle diagram  
• CopperLink Ethernet Extender’s rated voltage: 5.0 VDC  
• CopperLink Ethernet Extender’s rated current: 1 A DC  
External AC universal power supply  
• Output from power supply: 5 VDC, 2A  
• Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
An approved external power supply that incorporates a  
disconnect device must be used and positioned within  
easy reach of the operator’s position.  
Caution  
Caution  
Connect the equipment to a 5 VDC source that is electri-  
cally isolated from the AC source. The 5 VDC source is to  
be reliably connected to earth.  
External 48 VDC power supply  
• Input  
Rated voltage: 36–60 VDC  
Rated current: 0.25 A DC at nominal 48 VDC  
3-pin locking connector, 3.5 mm pitch  
Reverse polarity protection  
Transient over-voltage protection, 100 VDC at 2 ms  
• Output  
Rated voltage: 5 VDC 5%, 5W  
Rated current; 1 A DC  
6-inch cable terminated with 2.5 mm barrel plug, center positive  
An approved external power supply that incorporates a  
disconnect device must be used and positioned within  
easy reach of the operator’s position.  
Caution  
Connect the equipment to a 36–60 VDC source that is  
electrically isolated from the AC source. The 36–60 VDC  
source is to be reliably connected to earth.  
Caution  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3.5 CONSOLE PORT  
The Console Port is only intended for use by Patton Electronics Technical  
Support technicians.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.0 OPERATION  
Once the CopperLink Ethernet Extenders are properly installed, they  
should operate transparently. No user settings required. This section  
describes reading the LED status monitors.  
4.1 FRONT PANEL LED STATUS MONITORS  
The Models 2156 and 2157 feature eight front-panel LEDs that monitor  
power, Ethernet signals, and the CopperLink connection. Figure 9 shows  
the front panel location of each LED. Table 1 describes the LED functions.  
Figure 9. CopperLink Ethernet Extender standalone unit front panel  
Table 1: Front panel LED description  
LED  
Description  
Power  
WAN  
When lit, indicates the unit is powered on  
Link  
On solid—link is connected  
Off—No signal detected  
TX  
RX  
Flashing—Data is being transmitted from the local unit to the  
remote unit  
Flashing—Data is being received at the local unit from the  
remote unit  
Ethernet  
Link  
100 M  
TX  
On—Ethernet is linked  
On—100 Mbps Ethernet is selected  
Flashing—When data is transmitted from the unit to the LAN  
Flashing—When data is received from the LAN  
RX  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
APPENDIX A  
SPECIFICATIONS  
A.1 GENERAL CHARACTERISTICS  
• Compact low cost plug-and-play router  
• 10/100 Ethernet  
• Unlimited host support  
• Eight front panel LEDs indicate Power, WAN, Ethernet LAN speed and  
status  
• Convenient and standard RJ connectors for Ethernet and line  
• External UI or 48 VDC power supply options  
• Standard 1-year warranty  
A.2 WAN CHARACTERISTICS  
• 2.3 Mbps (Model 2156) or 4.6 Mbps speed (Model 2157)  
• RJ-11 connector  
• Uses two-wire unconditioned twisted-pair  
A.3 ETHERNET  
• Full-duplex, auto-sensing,10Base-T/100Base-TX Ethernet  
• Standard RJ-45 and built-in MDI-X crossover switch  
• IEEE 8021.d transparent learning bridge up to 1,024 addresses and  
spanning tree  
• Compatible with 802.1Q VLAN  
• Addresses deleted after 5 minutes of inactivity  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
A.4 EXTENSION DISTANCE AND RATE  
• 2.3 Mbps (Model 2156) or 4.6 Mbps speed (Model 2157)  
• Distances up to 30,000 ft (9,144 m) on 24 AWG (0.4 mm) wire  
• Auto-adjusting rate picks best rate for a given extension distance (see  
tables below)  
Table 2: Model 2156 Extension Distances  
No Noise  
DSL line  
rate  
26g (0.4 mm)  
24g (0.5 mm)  
22g (0.6 mm)  
20g (0.8 mm)  
19g (0.9 mm)  
N
kbps  
miles  
km  
miles  
km  
miles  
km  
miles  
km  
miles  
km  
3
200  
392  
4.4  
4.0  
3.8  
3.5  
3.0  
2.8  
2.5  
2.3  
7.0  
6.6  
6.2  
5.6  
4.9  
4.6  
4.0  
3.8  
5.7  
5.4  
5.1  
4.6  
4.0  
3.7  
3.3  
3.1  
9.4  
8.8  
8.3  
7.5  
6.4  
6.1  
5.3  
5.0  
8.0  
7.5  
7.1  
6.0  
5.2  
4.9  
4.2  
4.0  
13.1  
12.3  
11.6  
9.8  
10.3  
9.7  
9.2  
7.8  
6.7  
6.4  
5.6  
5.3  
16.8  
15.8  
14.9  
12.7  
11.0  
10.3  
9.0  
12.1  
10.8  
9.7  
8.8  
7.5  
6.7  
5.9  
5.6  
19.7  
17.5  
15.8  
14.3  
12.3  
11.0  
9.6  
6
8
520  
12  
18  
24  
32  
36  
776  
1160  
1544  
2056  
2312  
8.4  
7.9  
6.9  
6.6  
8.6  
9.1  
Table 3: Model 2157 Extension Distances  
No Noise  
DSL line  
rate  
26g (0.4 mm)  
24g (0.5 mm)  
22g (0.6 mm)  
20g (0.8 mm)  
19g (0.9 mm)  
N
kbps  
miles  
km  
miles  
km  
miles  
km  
miles  
km  
miles  
km  
3
200  
392  
4.4  
4.0  
3.8  
3.5  
3.0  
2.8  
2.5  
2.3  
2.3  
2.2  
2.1  
1.9  
1.7  
1.5  
7.0  
6.6  
6.2  
5.6  
4.9  
4.6  
4.0  
3.8  
3.7  
3.6  
3.4  
3.1  
2.8  
2.5  
5.7  
5.4  
5.1  
4.6  
4.0  
3.7  
3.3  
3.1  
3.0  
3.0  
2.7  
2.5  
2.3  
2.0  
9.4  
8.8  
8.3  
7.5  
6.4  
6.1  
5.3  
5.0  
5.0  
4.8  
4.5  
4.1  
3.7  
3.3  
8.0  
7.5  
7.1  
6.0  
5.2  
4.9  
4.2  
4.0  
4.0  
3.9  
3.6  
3.3  
2.9  
2.6  
13.1  
12.3  
11.6  
9.8  
8.4  
7.9  
6.9  
6.6  
6.4  
6.3  
5.8  
5.3  
4.8  
4.2  
10.3  
9.7  
9.2  
7.8  
6.7  
6.4  
5.6  
5.3  
5.2  
5.0  
4.7  
4.3  
3.9  
3.4  
16.8  
15.8  
14.9  
12.7  
11.0  
10.3  
9.0  
12.1  
10.8  
9.7  
8.8  
7.5  
6.7  
5.9  
5.6  
5.5  
5.4  
4.9  
4.5  
4.1  
3.6  
19.7  
17.5  
15.8  
14.3  
12.3  
11.0  
9.6  
6
8
520  
12  
18  
24  
32  
36  
42  
48  
54  
60  
66  
72  
776  
1160  
1544  
2056  
2312  
2696  
3080  
3464  
3848  
4232  
4616  
8.6  
9.1  
8.4  
8.9  
8.2  
8.7  
7.6  
8.0  
7.0  
7.4  
6.3  
6.6  
5.5  
5.9  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
A.5 LED INDICATORS  
• Eight LED indicators  
• Power  
• WAN Link, Transmit, and Receive  
• Ethernet Link, 100M, Transmit, and Receive  
A.6 POWER AND POWER SUPPLY SPECIFICATIONS  
• Either AC or DC options are available  
• Connection to the CopperLink Ethernet Extender requires +5VDC  
±5% DC power (1.0A minimum). Center pin is +5V. The barrel type  
plug has a 2.5/5.5/10mm I.D./O.D./shaft length dimensions  
• CopperLink Ethernet Extender’s rated voltage: 5.0 VDC  
• CopperLink Ethernet Extender’s rated current: 1A DC  
A.7 ENVIRONMENTAL  
Temperature: 32–122°F (0–50°C)  
• Relative Humidity: 5–90%, non-condensing  
• Altitude: 0–15,000 ft (0–4,572 m)  
A.8 DIMENSIONS  
1.5H x 4.2W x 5.8D in. (3.8H x 10.6W x 14.8D cm)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
APPENDIX B  
MODELS 2156 AND 2157 SERIES FACTORY  
REPLACEMENT PARTS AND ACCESSORIES  
Patton Model #  
Description  
2156 Base Models  
2156/L  
CopperLink Ethernet Extender; Line: RJ-11 (Local)  
CopperLink Ethernet Extender; Line: RJ-11 (Remote)  
2156/R  
2156-2PK  
CopperLink Ethernet Extender Kit: includes one local (L) and  
one remote (R) Model 2156  
2157 Base Models  
2157/L  
CopperLink Ethernet Extender; Line: RJ-11 (Local)  
CopperLink Ethernet Extender; Line: RJ-11 (Remote)  
2157/R  
2157-2PK  
CopperLink Ethernet Extender Kit: includes one local (L) and  
one remote (R) Model 2157  
2156 and 2157 User Manual  
07M2156_2157  
Power Supplies  
08055DCUI  
Power Cords*  
0805US  
User Manual  
100–240VAC (+5V reg. DC/2A) Universal Input Adapter.  
American Power Cord  
European Power Cord CEE 7  
United Kingdom Power Cord  
Australian Power Cord  
Denmark Power Cord  
France/Belgium Power Cord  
India Power Cord  
0805EUR  
0805UK  
0805AUS  
0805DEN  
0805FR  
0805IN  
0805IS  
Israel Power Cord  
0805JAP  
Japan Power Cord  
0805SW  
Switzerland Power Cord  
*Only required with optional UI power supply (08055DCUI)  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
APPENDIX C  
MODELS 2156 AND 2157 SERIES INTERFACE PIN ASSIGNMENT  
C.1 10/100BASE-T INTERFACE  
RJ-45  
• Pin 1: TX+  
• Pin 2: TX-  
• Pin 3: RX+  
• Pin 6: RX-  
• Pins 4, 5, 7, 8: no connection  
C.2 COPPERLINK INTERFACE  
RJ-11  
• Pin 2: RING  
• Pin 3: TIP  
• Pins 1 & 4: no connection  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Notes  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
Copyright © 2002  
Patton Electronics Company  
All Rights Reserved.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Clothes Dryer T 8023 C User Manual
Multiquip Portable Generator DCA400 User Manual
National Instruments Network Card FP RLY 420 User Manual
NETGEAR All in One Printer PS101 User Manual
New Media Technology Portable Multimedia Player multi media User Manual
Niles Audio Car Speaker AT8000 User Manual
Nortel Networks Router BSR252 User Manual
Northern Industrial Tools Plumbing Product 1 2 HP SUMP PUMP User Manual
Omega Engineering Automobile Parts FL900 User Manual
Panasonic Microwave Oven F00039X90KT User Manual