| 	
		 Full Weather Station with Radio Controlled Clock   
					and Projection   
					(Model #:PS L02A)   
					User Manual   
					PS-L02A English Cover r8 op   
					1 
					2/13/04, 10:45 AM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				In this box, you will find:   
					ABOUT THIS GUIDE   
					Congratulations on your selection of the Philippe Starck   
					with Oregon Scientific Full Weather Station with Radio   
					Controlled Clock and Projection (PS L02A). This   
					innovative time piece provides not only time keeping,   
					but also alarm clock, indoor and wireless outdoor   
					temperature, humidity monitoring, weather forecast, and   
					projection clock features into one convenient package.   
					• 
					• 
					• 
					• 
					Main unit   
					Remote sensor   
					Batteries   
					AC/DC power adapter   
					Keep this manual handy as you use your new product.   
					It contains practical step-by-step instructions, as well as   
					technical specifications and warnings you should know.   
					2 
					PS-L02A English r8 op   
					2 
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				PRODUCT OVERVIEW   
					TOP VIEW   
					DESCRIPTIONS   
					1.   
					2.   
					3.   
					Snooze/Light and Projection Button   
					Light sensor   
					Projection lens   
					1 
					2 
					3 
					3 
					PS-L02A English r8 op   
					3 
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				LCD DISPLAY   
					DESCRIPTIONS   
					1.   
					2.   
					3.   
					4.   
					5.   
					6.   
					7.   
					8.   
					Low batteries icon   
					Clock   
					Barometer   
					Weather forecast   
					Moon phase   
					Calendar   
					Temperature and humidity   
					Alarm   
					1 
					2 
					3 
					4 
					7 
					8 
					5 
					6 
					4 
					PS-L02A English r8 op   
					4 
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				BACK VIEW   
					BUTTON DESCRIPTIONS   
					1.   
					2.   
					3.   
					4.   
					5.   
					6.   
					7.   
					Focus – focus projector   
					Select – switch modes / change settings   
					Rotation – rotate projector   
					Up – increase setting / activate auto-synch   
					Down – decrease setting / deactivate auto-synch   
					Alarm –activate / deactivate alarm   
					Channel – switch remote unit   
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					5 
					PS-L02A English r8 op   
					5 
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				BOTTOM VIEW   
					DESCRIPTIONS   
					1.   
					2.   
					3.   
					4.   
					5.   
					Battery compartment   
					Light sensitivity knob   
					Reset button   
					Backlight switch   
					DC power input jack   
					1 
					2 3   
					4 
					5 
					NOTE   
					AC power adapter not shown.   
					6 
					PS-L02A English r8 op   
					6 
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				REMOTE UNIT   
					DESCRIPTIONS   
					1.   
					2.   
					3.   
					4.   
					5.   
					6.   
					7.   
					8.   
					9.   
					Temperature / Trend display   
					Low battery icon   
					Humidity / Trend / Comfort Level display   
					°F / °C switches   
					Channel switches   
					Reset button   
					Battery compartment   
					Wall-mount hole   
					1 
					2 
					4 
					5 
					6 
					7 
					3 
					Battery compartment lid   
					8 
					9 
					7 
					PS-L02A English r8 op   
					7 
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				GETTING STARTED   
					NOTE   
					Insert the batteries in the remote unit before you   
					set up the main unit. Do not use rechargeable   
					batteries.   
					BATTERIES   
					Batteries for the remote and main units are supplied   
					with this product. Replace them whenever the low   
					battery signal ( ) displays. Remove the battery   
					compartment lid on the bottom of the main unit, and   
					insert the batteries. Use a small Phillips screwdriver to   
					remove the remote unit compartment lid. Be sure to   
					match the correct polarity, as shown in the battery   
					compartment. Before you close the lid, press the   
					RESET button with the point of a blunt object (such as   
					a ball point pen).   
					AC POWER ADAPTER   
					An AC power adapter is supplied for use with the main   
					unit. You must connect the power adapter if you wish   
					to use the continuous projection or backlight features.   
					The jack is located in the battery compartment.   
					NOTE   
					If the AC power becomes unavailable, the unit   
					will automatically switch to battery power.   
					8 
					PS-L02A English r8 op   
					8 
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				SWITCH BETWEEN MODES   
					Press SELECT. The select mode will flash. The display   
					will stop flashing if no key is pressed within 5 seconds.   
					NOTE   
					Additional remote units sold separately. If you   
					are using more than one remote unit, be sure to select a   
					different channel number for each unit.   
					CHANGE SETTINGS   
					INSTALLATION   
					Mount the remote unit on a flat surface using the recess   
					holes on the back of the unit.   
					Press and hold SELECT for 2 seconds. Then, press UP   
					or DOWN to change each setting. Press SELECT to   
					switch options.   
					For best results:   
					REMOTE UNIT SET UP   
					• 
					Before you insert the batteries, select the   
					measurement unit and channel number first.   
					Place the unit out of direct sunlight and moisture.   
					Do not place the remote unit more than   
					60 – 90 feet (20 – 30 meters) from the main   
					(indoor) unit.   
					Up to 3 remote units can be used with this product to   
					monitor outdoor temperature and humidity. The   
					measurement unit (°F or °C) and channel number (1, 2,   
					or 3) switches are located in the battery compartment,   
					and should be set prior to installation.   
					• 
					• 
					9 
					PS-L02A English r8 op   
					9 
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				• 
					Position the unit so that it faces the main (indoor)   
					unit. Minimize obstructions such as doors, walls,   
					and furniture.   
					RECEPTION   
					Reception takes 2 – 10 minutes to complete. Once   
					complete, the icon will stop blinking.   
					You may need to experiment with various locations to   
					get the best reception.   
					Strong signal   
					Weak signal   
					No signal   
					CLOCK   
					This product can automatically synchronize the date and   
					time with the US Atomic Clock. When the unit is within   
					932 miles (1500 km) of a RF signal, the reception icon   
					will blink.   
					NOTE   
					For best results, place the unit away from metal   
					or electrical objects, and near a window with a clear   
					view to the sky.   
					10   
					PS-L02A English r8 op   
					10   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				TO DISABLE OR ENABLE AUTO-   
					SYNCHRONIZATION   
					ALARM   
					When activated, the Melody Alarm starts quietly, then   
					gradually becomes louder. It shuts off after two minutes.   
					The LCD display lights up for the first 8 seconds.   
					In Clock mode, press DOWN for 2 seconds to disable   
					the auto-synchronization. The unit will not respond to   
					radio signals until you reactivate the synchronization.   
					SET ALARM   
					To enable auto-reception, press UP for 2 seconds.   
					1.   
					2.   
					3.   
					Press SELECT several times until the Alarm area   
					flashes.   
					Press and hold SELECT for 2 seconds to enter   
					the setting mode.   
					SET OR CHANGE THE CLOCK   
					1.   
					2.   
					3.   
					Press SELECT to switch to the Clock Mode.   
					The time will flash.   
					Press and hold SELECT for 2 seconds to enter   
					the setting mode.   
					Select the US time-zone (Pacific, Mountain,   
					Central or Eastern), 12/24-hour format, hour, and   
					minute. Press UP or DOWN to change the   
					setting. Press SELECT to confirm.   
					Select the hour, minute,   
					melody (1-7) and   
					volume level (Lo or Hi). Press UP or DOWN to   
					change the setting. Press SELECT to confirm.   
					Press SELECT again when you are finished.   
					4.   
					11   
					PS-L02A English r8 op   
					11   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				SNOOZE   
					1.   
					2.   
					3.   
					Press SELECT several times until the calendar   
					area flashes.   
					Press and hold SELECT for 2 seconds to enter   
					the calendar setting mode.   
					Select the year, month, date, and language. Press   
					UP or DOWN to change the setting. Press   
					SELECT to confirm.   
					Press the SNOOZE/LIGHT button the top of the unit   
					to temporarily disable the alarm for 8 minutes. The   
					alarm icon will blink while Snooze is activated.   
					TO TURN THE ALARM OFF OR ON   
					Press any button to stop the alarm.   
					To turn the alarm off completely (deactivate it for the   
					next day), press ALARM.   
					NOTE   
					The language options are (E) English, (F)   
					French, (D) German, (I) Italian, and (S) Spanish.   
					CALENDAR   
					MOON PHASE   
					Press SELECT until the Calendar Area flashes. Then,   
					press UP or DOWN to change the date and view the   
					corresponding moon phase.   
					SET DATE   
					Clock auto-synchronization must be deactivated before   
					you manually set the date. (→ pg.11)   
					12   
					PS-L02A English r8 op   
					12   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				BAROMETER   
					Description   
					Pressure change   
					(mb/hPa)   
					Trend   
					This product tracks barometric pressure changes   
					over the past 24 hours to provide the weather forecast   
					(→ pg.14) and a trend line showing the direction of   
					barometric change. Barometric changes are measured   
					by the main (indoor) unit.   
					1 hr   
					6 hr   
					Rising   
					+1   
					+3   
					Steady   
					Steady   
					-1   
					Steady   
					-3   
					BAROMETRIC TREND   
					The barometric trend arrow for the last 30 minutes is   
					always displayed.   
					Failing   
					VIEW THE LAST 24 HOURS   
					Press SELECT 2 times until the Barometer Area   
					flashes. Then, press UP or DOWN to view the last   
					24 hours history.   
					13   
					PS-L02A English r8 op   
					13   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				SET UNIT AND ALTITUDE   
					WEATHER FORECAST   
					You can set the unit of measurement (mb/hPa or inHg)   
					and altitude. Setting the altitude allows the product to   
					take more accurate barometric measurements.   
					This product forecasts the next 12 to 24 hours of   
					weather within a 19 - 31 mile (30 to 50 km) radius with   
					70 to 75 percent accuracy. The weather forecast is   
					always displayed.   
					1.   
					Press SELECT 2 times until the Barometer Area   
					flashes.   
					Partly   
					Cloudy   
					Clear   
					Rainy   
					Cloudy   
					2.   
					3.   
					Press and hold SELECT for 2 seconds.   
					Select altitude: -100 meters to 2500 meters in   
					increments of 10 (-328 to 8202 feet in increments   
					of 32.81 feet) and the unit of measurement (mb/   
					hPa or inHg). Press UP or DOWN to change the   
					setting. Press SELECT to confirm.   
					TEMPERATURE AND HUMIDITY   
					With the press of a button, you can check the current   
					indoor or outdoor temperature, humidity percentage,   
					comfort level, trend, and record measurements.   
					14   
					PS-L02A English r8 op   
					14   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				Outdoor measurements are collected by the remote   
					unit.   
					SELECT REMOTE UNIT CHANNEL   
					While in the Temperature / Humidity Mode, press   
					CHANNEL to switch between CH 1, 2, or 3, or press   
					and hold CHANNEL for 2 seconds to enter Auto scan   
					mode. If only 1 remote unit is in use, you will not be   
					able to change channels or Auto scan. If you select   
					“Auto”, the channel will change every 3 seconds. To   
					deactivate, press and hold CHANNEL for 2 seconds   
					again.   
					Temperature is give at the top; humidity is below.   
					VIEW MIN / MAX / CURRENT MEASUREMENTS   
					Press SELECT 3 times until the Temperature and   
					Humidity Areas flash. Press UP or DOWN to scan the   
					readings.   
					CLEAR MIN / MAX MEASUREMENTS   
					SENSOR SEARCHING   
					While viewing Min/Max measurements, press and hold   
					UP or DOWN for 2 seconds until a beep sounds. This   
					clears the previous measurements from the memory.   
					If there is no remote unit signal, the temperature and   
					humidity measurement will be blank. Check the remote   
					unit batteries, or press and hold UP and DOWN for   
					2 seconds to search for the remote unit(s).   
					15   
					PS-L02A English r8 op   
					15   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				COMFORT ZONE   
					The indoor and outdoor comfort zones are shown for   
					Searching   
					No sensor   
					Sensor found   
					the following conditions.   
					Temperature   
					Any   
					Zone   
					Wet   
					Dry   
					Relative Humidity   
					>70%   
					NOTE   
					Signals from household electrical appliances   
					such as doorbells and home security systems can   
					cause temporary reception failures between the indoor   
					and outdoor units. This is normal and does not affect   
					the general performance of the product. Reception will   
					automatically resume once the interference ends.   
					Any   
					<40%   
					68 - 77 °F   
					(20 - 25 °C)   
					40 – 70%   
					Comfort   
					16   
					PS-L02A English r8 op   
					16   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				TRENDS   
					SET UNIT   
					The trend arrow for the last 30 minutes always displays.   
					Indoor and outdoor temperature and humidity trends are   
					shown separately.   
					While in Temperature / Humidity Mode, press SELECT   
					for 2 seconds. Press UP or DOWN to switch between   
					°F and °C. Press SELECT to confirm.   
					Temperature   
					Relative Humidity   
					+3%   
					BACKLIGHT   
					Press SNOOZE/LIGHT to illuminate the backlight for   
					5 seconds.   
					Trend   
					+0.9 °F   
					CONTINUOUS BACKLIGHT   
					The AC power adapter must be plugged in to use this   
					feature (→ pg.8).   
					Steady   
					Steady   
					-3%   
					-0.9 °F   
					1.   
					The BACKLIGHT switch is located in the battery   
					compartment. Move it to the “ON” position to   
					enable the continuous backlight.   
					Move it to the “OFF” position to disable.   
					17   
					PS-L02A English r8 op   
					17   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				2.   
					3.   
					Move it to the “AUTO” position to enable   
					continuous backlight controlled by light intensity.   
					When activated, the backlight will be on   
					whenever the unit perceives that the room is dark.   
					The Light Sensitivity knob is located in the   
					battery compartment. Rotate to adjust.   
					PROJECTOR   
					This product has a built-in projector for viewing time   
					and alarm status at night.   
					NOTE   
					The maximum projection range is 2 meters   
					(6 feet). The image gets larger the farther you display it.   
					PROJECT TIME / ALARM STATUS   
					In a darkened room, press SNOOZE/LIGHT to display   
					the time and alarm status for 5 seconds.   
					FLIP IMAGE   
					Press SNOOZE/LIGHT again while the projector is on.   
					4.   
					When activated, the continuous backlight will be   
					half as bright as usual. To achieve full brightness,   
					press SNOOZE/LIGHT.   
					18   
					PS-L02A English r8 op   
					18   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				ROTATE IMAGE   
					Press and hold SNOOZE/LIGHT for 2 seconds again   
					The ROTATION switch is located on the back of the   
					unit. Rotate to adjust.   
					to deactivate.   
					RESET SYSTEM   
					FOCUS IMAGE   
					The RESET buttons are located in the battery   
					compartments for the main and remote units. Press   
					these buttons with the tip of a blunt object (such as a   
					ball point pen) whenever you change the batteries, or   
					whenever performance is not behaving as expected   
					(e.g., unable to establish radio frequency link with   
					remote unit or automatic clock, etc.) This will return all   
					settings to default value, and you will lose all stored   
					information (minimum / maximum temperature and   
					humidity, etc.).   
					The FOCUS switch is located on the back of the unit.   
					Rotate to adjust.   
					CONTINUOUS PROJECTION   
					The AC power adapter must be plugged in to use this   
					feature (→ pg.8).   
					Press and hold SNOOZE/LIGHT for 2 seconds when   
					the projection is on. When activated, the time and alarm   
					atatus will project continuously   
					19   
					PS-L02A English r8 op   
					19   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				• 
					Do not subject the main unit to extreme force,   
					shock, or fluctuations in temperature or humidity.   
					Do not tamper with the internal components.   
					Do not mix new and old batteries or batteries of   
					different types.   
					Do not use rechargeable batteries with this   
					product.   
					Remove the batteries if storing this product for a   
					long period of time.   
					SAFETY AND CARE   
					Clean the unit with a slightly damp cloth and mild   
					detergent. Avoid dropping the unit or placing it in a   
					location where the AC power adapter will be stepped   
					on.   
					• 
					• 
					• 
					• 
					WARNINGS   
					This product is designed to give you years of service if   
					handled properly. Observe the following guidelines:   
					• 
					• 
					Do not scratch the LCD display.   
					Do not make any changes or modifications to this   
					product. Unauthorized changes may void your   
					right to use the product.   
					Do not make any unauthorized modifications to   
					NOTE   
					this product. Unauthorized modifications will void the   
					warranty.   
					• 
					• 
					The content of this user manual are subject to   
					change without notice.   
					Images not drawn to scale.   
					• 
					Never immerse the unit in water. This can cause   
					electrical shock and damage the unit.   
					20   
					PS-L02A English r8 op   
					20   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				TROUBLESHOOTING   
					Problem   
					Symptom   
					Remedy   
					Cannot locate Check batteries   
					Problem   
					Symptom   
					Remedy   
					Remote   
					unit   
					remote unit   
					(→ pg.8)   
					Temperature is out-of-   
					range.   
					Shows “LLL”   
					or “HHH”   
					Temp   
					Check location   
					(→ pg.9)   
					Strange date /   
					month   
					Calendar   
					Backlight   
					Change language   
					(→ pg.12)   
					Check sensors.   
					Only one sensor is   
					working (→ pg.15 )   
					Cannot   
					change   
					channel   
					No continuous   
					backlight   
					Plug in AC power   
					adapter. Check the   
					BACKLIGHT switch.   
					(→ pg.8, 17)   
					Make sure auto-   
					Cannot   
					auto-   
					synchronize   
					Clock   
					synchronization is   
					enabled (→ pg. 11)   
					1. Remove batteries.   
					2. Press RESET. All   
					memory items will   
					return to default.   
					Projector   
					No   
					Plug in AC   
					power   
					adapter   
					continuous   
					backlight or   
					projection   
					(→ pg.8, 17, 18)   
					21   
					PS-L02A English r8 op   
					21   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				SPECIFICATIONS   
					Problem   
					Symptom   
					Remedy   
					3. Replace batteries.   
					4. Place clock near   
					window / away   
					Main unit dimensions   
					L x W x H   
					7.1 x 1.77 x 7.3 inches   
					(181 x 45 x 185.3 mm)   
					from electrical   
					Weight   
					2.02 lbs / 914 grams with battery   
					devices, and wait   
					10 – 20 minutes.   
					Remote unit dimensions   
					L x W x H   
					3 x 1.4 x 3.1 inches   
					(75 x 35 x 78.3mm)   
					0.3 lbs / 136 grams with battery   
					If it still fails, you may   
					be too far from a   
					signal.   
					Weight   
					Disable auto-   
					synchronization   
					(→ pg.11)   
					Cannot   
					change   
					clock   
					Strange   
					reading   
					Set altitude / unit   
					(→ pg.14)   
					Baro   
					22   
					PS-L02A English r8 op   
					22   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				Temperature   
					Unit   
					Memory   
					Trend   
					Minimum / maximum   
					3% change   
					°F or °C   
					Range   
					Main unit: 23 ˚F to 122 ˚F   
					(-5 ˚C to 50 ˚C)   
					Barometer   
					Unit   
					Range   
					Remote Unit: -4 ˚F to 140 ˚F   
					(-20 ˚C to 60 ˚C )   
					mb/hPa or inHg   
					500 to 1050mb   
					Resolution   
					Comfort   
					0.2° F (0.1 °C)   
					(14.77 to 31.01 inHg)   
					1mb (0.03 inHg)   
					-328 to 8202 feet   
					(-100 to 2500 meters)   
					Rainy, cloudy, partly cloudy, sunny   
					24 hour   
					1mb change in 1 hour or 3mb   
					change in 6 hours   
					68 °F to 77 °F (20 °C to 25 °C)   
					(see also, Relative humidity)   
					Minimum / maximum   
					+/- 0.9 ˚F (+/- 0.5 ˚C) change   
					Resolution   
					Altitude   
					Memory   
					Trend   
					Display   
					Memory   
					Trend   
					Relative humidity   
					Range   
					Resolution   
					Comfort   
					Main & Remote Unit: 25% to 95%   
					1%   
					40% to 70% (see also,   
					Temperature)   
					23   
					PS-L02A English r8 op   
					23   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				Remote unit   
					RF frequency   
					Range   
					Projector   
					Display   
					Rotation   
					Focusing   
					Projection   
					433 MHz   
					98 feet (30 meters) with no   
					obstructions   
					approximately every 40 seconds   
					1, 2, or 3   
					°F or °C   
					Current time / alarm status   
					180° and image flip   
					Manual   
					Transmission   
					Channel No.   
					Unit   
					5-second or continuous   
					Power   
					Main unit   
					4 x UM-3 (AA) 1.5V alkaline   
					batteries (back-up)   
					Radio-controlled clock   
					Synchronization Auto or disabled   
					AC/DC 6V power adapter   
					(for normal operation and continuous   
					backlight and projector)   
					2 x UM-4 (AAA) 1.5V alkaline   
					batteries   
					Clock display   
					Hour format   
					Calendar   
					HH:MM:SS   
					12hr AM/PM (default) or 24hr   
					DD/MMM; weekday selection in 5   
					languages (E, D, F, I, S)   
					High, medium, and low tide   
					7 melody; 2 minute crescendo   
					8 minutes   
					Remote unit   
					Moon phase   
					Alarm   
					Snooze   
					24   
					PS-L02A English r8 op   
					24   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				Warning: Changes or modifications to this unit not   
					expressly approved by the party responsible for   
					compliance could void the user's authority to operate   
					the equipment.   
					ABOUT OREGON SCIENTIFIC   
					
					more about other Oregon ScientificTM products such as   
					digital cameras, projection clocks, health and fitness   
					gear, and weather stations. The website also includes   
					contact information for our customer service   
					department, in case you need to reach us.   
					NOTE: This equipment has been tested and found to   
					comply with the limits for a Class B digital device,   
					pursuant to Part 15 of the FCC Rules. These limits are   
					designed to provide reasonable protection against   
					harmful interference in a residential installation. This   
					equipment generates, uses and can radiate radio   
					frequency energy and, if not installed and used in   
					accordance with the instructions, may cause harmful   
					interference to radio communications.   
					FCC STATEMENT   
					This device complies with Part 15 of the FCC Rules.   
					Operation is subject to the following two conditions:   
					(1) This device may not cause harmful interference, and   
					(2) This device must accept any interference received,   
					including interference that may cause undesired   
					operation.   
					25   
					PS-L02A English r8 op   
					25   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				However, there is no guarantee that interference will not   
					occur in a particular installation. If this equipment does   
					cause harmful interference to radio or television   
					reception, which can be determined by turning the   
					equipment off and on, the user is encouraged to try to   
					correct the interference by one or more of the following   
					measures:   
					DECLARATION OF CONFORMITY   
					The information below is not to be used as contact for   
					support or sales. Please call our customer service   
					number (listed on our website at   
					
					this product) for all inquiries instead.   
					We   
					• 
					• 
					Reorient or relocate the receiving antenna.   
					Name:   
					Oregon Scientific, Inc.   
					Address:   
					19861 SW 95th Place,   
					Tualatin, Oregon 97062 USA   
					Increase the separation between the   
					equipment and receiver.   
					• 
					• 
					Connect the equipment into an outlet on a   
					circuit different from that to which the receiver   
					is connected.   
					Telephone No.:   
					Fax No.:   
					1-800-853-8883   
					1-503-684-8883   
					Consult the dealer or an experienced radio/   
					TV technician for help.   
					26   
					PS-L02A English r8 op   
					26   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				declare that the product   
					Product No.:   
					PS L02A   
					CAUTION   
					Product Name:   
					Manufacturer:   
					Address:   
					Remote Thermo Hygro   
					IDT Technology Limited   
					— 
					— 
					— 
					The content of this manual is subject to change   
					without further notice.   
					Block C, 9/F, Kaiser Estate,   
					Phase 1, 41 Man Yue St.,   
					Hung Hom, Kowloon,   
					Hong Kong   
					Due to printing limitation, the displays shown in   
					this manual may differ from the actual display.   
					The contents of this manual may not be   
					reproduced without the permission of the   
					manufacturer.   
					is in conformity with Part 15 of the FCC Rules.   
					Operation is subject to the following two conditions:   
					1) This device may not cause harmful   
					interference.   
					2) This device must accept any interference   
					received, including interference that may   
					cause undesired operation.   
					© 2004 Oregon Scientific. All rights reserved.   
					27   
					PS-L02A English r8 op   
					27   
					2/13/04, 12:28 PM   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					Black   
				 |