IVnte6llig0ent0Fl-agHI/IIA
Innovative RFID Electronic Flags to
Replace Mechanical Flag and Kanban
Systems
• Doesn't need a program and can be used like a sensor.
• Advanced line construction at minimal cost.
• Saves space.
• Precise installation not required (Transmission distance:
100 mm max.).
• A verification function provided on multi-functional type.
• Addition of 16-bit models to the series responds to applica-
tions from Kanban to quality control.
• Equipped with a wiring reduction mode and communications
parity check function (16-bit models).
• Both NPN and PNP output available.
• FCC certified.
Ordering Information/Specifications
■ Amplifier
Type
Read-only (8-bit)
V600-HAR91 V600-HAR81
24 VDC 10%, ripple (p-p): 10%
Multi-functional (8-bit)
V600-HAM91 V600-HAM81
Read-only (16-bit)
V600-HAR92
Item
Model
Power supply
Current consumption 130 mA max.
Transistor output
Input
Transistor output or contact output
Short-circuit current: 3 mA (typical) (IN terminal and 0-V short-circuit)
OFF voltage:
15 to 30 VDC
Input impedance:
8.2 kΩ
OFF voltage:
ON voltage:
Input impedance:
Applied voltage:
15 to 30 VDC
0 to 5 VDC
8.2 kΩ
Short-circuit current:
3 mA (typical) (for 0-V short-circuit of
INHIBIT/TRG)
30 VDC max.
ON voltage:
0 to 5 VDC
Applied voltage:
30 VDC max.
NPN open collector
PNP open collector NPN open collector
PNP open collector out- NPN open collector output, 20 mA
Output
output, 20 mA max. at output, 20 mA max. output, 20 mA max. at put, 20 mA max. at 30
max. at 30 VDC, residual voltage: 2 V
30 VDC, residual volt- at 30 VDC, residual 30 VDC, residual volt- VDC, residual voltage: 2 V max.
age: 2 V max. voltage: 2 V max. age: 2 V max. max.
Diagnostic functions Checks for CPU errors and transmission errors
Insulation resistance 50 MΩ max. (at 500 VDC) between cable terminals and case
Dielectric strength
500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current: 1 mA max.)
2
Intelligent Flag I/II V600-HA
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Sensor
Model
Shape
V600-HS51
V600-HS61
V600-HS63
V600-HS67
Item
Transmission frequency 530 kHz
Ambient temperature
Storage temperature
Ambient humidity
−10 to 60°C
−25 to 75°C
35% to 95%
50 MΩ (at 500 VDC) between cable terminal and case
−10 to 70°C
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
1,000 VAC, 50/60 Hz for 1 min between cable terminal and case (leakage current: 1 mA max.)
IEC60529: IP67
Destruction: 10 to 2,000 Hz, 3-mm double amplitude, with Destruction: 10 to 500 Hz, 2-mm double amplitude, with 3
2 sweeps of 15 min each in 3 directions
sweeps of 11 min each in 3 directions
Destruction: 981 m/s2, 3 times each in 3 directions (18
times total)
Destruction: 490 m/s2, 3 times each in 3 directions (18
times total)
Shock resistance
Cable length
2 m (fixed)
Wireless transmission
error direction
16-bit CRC (Cyclic Redundancy Check) in both directions
Indicator
Weight
---
Power: green
Approx. 70 g
Approx. 190 g
Approx. 540 g
■ Transmission Distance Specifications
Recommended Combinations
Amplifier
Sensor
V600-HAR91/-HAR81/-HAM91/-HAM81/-HAR92
V600-HS61 V600-HS63
0.5 to 3.0 mm
Data Carrier
V600-HS51
0.5 to 3.0 mm
V600-HS67
Memory
EEPROM
(Battery-
less type)
V600-D23P53
---
---
---
V600-D23P54
V600-D23P55
V600-D23P61
V600-D23P66N
0.5 to 5.0 mm
0.5 to 7.0 mm
0.5 to 8.0 mm
---
0.5 to 5.5 mm
---
0.5 to 7.0 mm
0.5 to 9.5 mm
2 to 16 mm
5 to 30 mm
5 to 25 mm
5 to 35 mm
5 to 35 mm
5 to 45 mm
10 to 30 mm
10 to 65 mm
2 to 15 mm
---
0.5 to 9.0 mm
---
---
5 to 35 mm
5 to 30 mm
10 to 70 mm
10 to 50 mm
10 to 60 mm
10 to 40 mm
10 to 100 mm
---
V600-D23P66SP ---
---
V600-D23P71
V600-D23P72
V600-D8KR12
V600-D8KR13
V600-D8KR04
V600-D2KR16
---
---
---
0.5 to 18 mm
Memory
SRAM
(Built-in-
battery
type)
5 to 15 mm
5 to 18 mm
---
---
---
---
---
---
Note: 1. The specifications take fluctuations in ambient temperature and slight differences between products into account.
2. The read distance and write distance are the same.
3. Sensor Installation Conditions
• V600-HS51:When flush-mounted in iron
Axial offset from the Data Carrier: 2.0 mm
•
•
•
V600-HS61: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: 2.0 mm
V600-HS63: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: 10.0 mm
V600-HS67: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: 10.0 mm
4. Data Carrier Installation Conditions
•
•
•
•
•
V600-D23P53/-P54: When flush-mounted in iron
V600-D23P55/-P66N/-P66SP/-P71/-P72: When surface-mounted on resin (no metal on the backside)
V600-D23P61: When surface-mounted on metal (ferrous)
V600-D8KR12/-13/-04: When surface-mounted on metal (ferrous)
V600-D2KR16: When the Data Carrier attached to the holder is mounted on a metal (ferrous) surface
5. The transmission distance specified in the specifications is also applicable when the Data Carrier is mounted on non-metallic surfaces.
6. The Data Carrier is stationary.
4
Intelligent Flag I/II V600-HA
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
Host
Sensor
(Cable length: fixed to 2 m)
Programmable Controller, I/O terminal, B7A, CompoBus/S, etc.
Sensor Controller
Terminal block wiring
Connector
connection
Interface cable
V600-A6R
V600-A6M
Amplifier (Cable length:
fixed to 0.5 m, with connector)
interface
Connector pins: 20
Cable lengths: 2 m, 5 m,
10 m
Connector pins: 26
Cable lengths: 2 m, 5 m,
10 m
Connector
connection
Connector
connection
Connector
connection
Amplifier
Power
supply
24 VDC
V600
-HAR91/
HAR81
Power
supply
24 VDC
V600
-HAM91/
HAM81
Power
supply
24 VDC
V600
-HAR92
Connector
connection
Connector connection
V600-HS61
Connector connection
Sensor
V600-HS51
V600-HS63
V600-HS67
Interface cable available in
three lengths: 2 m,
5 m, and 10 m (10 m max.)
Wireless
transmission
Wireless
transmission
Data Carrier
V600
V600
V600
V600
V600
V600
V600
V600
V600
V600
V600
-D23P53
-D23P54 -D23P55 -D23P61 -D23P66N -D23P66SP -D23P71
-D23P72 -D8KR12 -D8KR04 -D2KR16
Intelligent Flag I/II V600-HA
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Characteristic Data (Typical)
■ Transmission Range
Combinations with the V600-HS51 Sensor
V600-HS51 & V600-D23P53
V600-HS51 & V600-D23P54
V600-HS51 & V600-D23P55
Y
Y
Y
Y
Y
Y
15
X
12
X
X
8
4
10
5
8
4
–15
–10
–5
0
5
10
15
X
–8
–4
0
4
8
X
–12
–8
–4
0
4
8
12
X
V600-HS51 & V600-D23P61
V600-HS51 & V600-D23P66N
V600-HS51 & V600-D8KR12
Y
Y
Y
Y
Y
Y
30
15
30
X
X
X
20
10
10
5
20
10
–15
–10
–5
0
5
10
15
X
–30
–20
–10
0
10
20
30
X
–30
–20
–10
0
10
20
30
X
Combinations with the V600-HS61 Sensor
V600-HS61 & V600-D23P53
V600-HS61 & V600-D23P54
V600-HS61 & V600-D23P55
Y
Y
Y
Y
Y
Y
15
12
8
X
8
4
X
X
10
5
4
–12
–8
–4
0
4
8
12
X
–8
–4
0
4
8
X
–15
–10
–5
0
5
10
15
X
V600-HS61 & V600-D23P61
V600-HS61 & V600-D23P72
V600-HS61 & V600-D8KR12
Y
Y
Y
Y
Y
Y
30
30
20
15
10
5
X
X
X
20
10
20
10
–30
–20
–10
0
10
20
30
X
X
–25 –20 –15 –10 –5
0
5
10 15 20 25
X
–30
–20
–10
0
10
20
30
6
Intelligent Flag I/II V600-HA
Download from Www.Somanuals.com. All Manuals Search And Download.
Combinations with the V600-HS63 Sensor
V600-HS63 & V600-D23P55
V600-HS63 & V600-D23P61
V600-HS63 & V600-D23P66N
Y
50
Y
Y
Y
Y
Y
30
40
30
20
10
30
X
X
X
20
10
20
10
–50 –40 –30 –20 –10
0
10
20
30
40
50 X
–40
–30
–20
–10
0
10
20
30
40 X
–30
–20
–10
0
10
20
30
X
V600-HS63 & V600-D23P66SP
V600-HS63 & V600-D23P71
V600-HS63 & V600-D23P72
Y
Y
Y
Y
Y
Y
50
40
30
20
10
60
60
X
X
X
40
20
40
20
–60
–40
–20
0
20
40
60
X
–50 –40 –30 –20 –10
0
10 20 30 40 50 X
–60
–40
–20
0
20
40
60
X
V600-HS63 & V600-D8KR12
V600-HS63 & V600-D8KR04
V600-HS63 & V600-D2KR16
Y
Y
Y
Y
Y
Y
80
60
40
20
60
60
X
X
X
40
20
40
20
–60
–40
–20
0
20
40
60
X
–80 –60 –40 –20
0
20 40 60 80
X
–80
–60
–40 –20
0
20
40
60
80X
Intelligent Flag I/II V600-HA
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Combinations with the V600-HS67 Sensor
V600-HS67 & V600-D23P66N
V600-HS67 & V600-D23P66SP
V600-HS67 & V600-D23P71
Y
Y
Y
Y
Y
Y
80
80
100
80
60
40
20
60
40
20
60
40
X
X
X
20
–80 –60 –40 –20
0
20
40
60
80 X
–80 –60 –40 –20
0
20
40
60
80 X
–100 –80 –60 –40 –20
0
20 40 60 80 100 X
V600-HS67 & V600-D23P72
V600-HS67 & V600-D8KR12
V600-HS67 & V600-D8KR13
Y
Y
Y
Y
Y
Y
80
80
100
X
80
60
40
20
X
60
40
20
60
40
20
X
–80 –60 –40 –20
0
20
40
60
80 X
–80 –60 –40 –20
0
20
40
60
80 X
–100 –80 –60 –40 –20
0
20 40 60 80 100X
V600-HS67 & V600-D8KR04
Y
Y
120
X
80
40
–120
–80
–40
0
40
80
120 X
■ Transmission Time
The transmission time refers to the time required for communications between the Sensor and the Data Carrier. It is used for calculating the travel
speed of the auto command.
DC speed
(conveyor
speed)
Distance travelled in the transmission range
Transmission time
=
Model
Read
V600-HAR91/-HAR81/-HAM91/-HAM81
Write
V600-HAR92
Read
Mode type DATA READ mode,
VERIFY READ mode
BYTE mode
BIT SET mode, BIT
CLEAR mode
DATA READ mode
Data Carrier type
EEPROM
SRAM
75 ms
60 ms
138 ms
95 ms
150 ms
107 ms
77 ms
62 ms
Example: Combinations with the V600-HAR91, V600-HS63, and V600-D8KR04 Sensors.
Note: 1. The DC speed varies depending on transmission distance Y
and the axial offset. It is recommended that you refer to the
transmission range graphs and use the product where the
range is the largest.
Y
Y
80
60
40
20
X
2. This calculation is intended as a guideline only. Perform a
test with the actual product prior to use.
3. This equation does not include transmission error process-
ing.
–80 –60 –40 –20
0
20 40 60 80
X
75 × 10-3 (m)
60 × 10-3 × 1/60 (min)
DC speed
(conveyor
speed)
75 (mm)
60 (ms)
=
=
= 75 (m/min)
8
Intelligent Flag I/II V600-HA
Download from Www.Somanuals.com. All Manuals Search And Download.
Circuit Configuration
V600-HAR91
V600-HAM91
V600-HAR81
V600-HAM81
Input Circuit
Input Circuit
+DC
24 V
Tr
IN
8.2 kΩ
ON/
OFF
Main circuit
IN
Main circuit
8.2 kΩ
Tr
0 V
0 V
Output Circuit
Output Circuit
+DC
OUT
OUT
0 V
Main circuit
Main circuit
0 V
V600-HAR92
Input Circuit
24 V
8.2 kΩ
ON/
OFF
Main circuit
IN
Tr
0 V
Output Circuit
OUT
0 V
Main circuit
Precautions
The following OMRON products cannot be connected to this product.
■ Cautions
• CVM1-OD219, C20H, C28H, C40H, or C60H Programmable
Controllers
!Caution
• Sensor Controllers other than from the S3D2 Series
Be sure to house the V600-HA@91/-HA@81/-HA@92 together with
their connectors and cable in control boxes when using them and
do not expose them to water, oil, dust, metal powder, corrosive
gas, or organic solvent, otherwise they may malfunction, suffer
damage, or burn.
When using a contact output, pay careful attention to chattering and
to the minimum switching current. Also note that the minimum switch-
ing current may be specified for some solid-state outputs.
When connecting an inductive load or an electrical device that tends
to generate noise to the output, connect a diode in parallel with the
load. Connect the cathode side of the diode to the positive side of the
power source.
!Caution
The connectors of the V600-HA@91/-HA@81/-HA@92 can be
mounted to metal plates, provided that there is an insulation plate
with a thickness of 1.5 mm minimum between each of the connec-
tors and metal plates.
L
DC
Open collector output
Diode
power supply
Input/Output
The Data Input and Data Output lines are set to “1" when the transis-
tor turns ON and to “0" when it turns OFF.
Do not use a solid-state output with the following ratings with the
V600-HAM91/-HAM81, otherwise an external input error may result.
Diode
Peak inverse voltage
Minimum of three times of the load voltage
Average rectified current: 1 A
1. Maximum switching current: 1 A min.
2. Minimum switching current: 10 mA min.
3. Response time (ON to OFF): 3 ms min.
Intelligent Flag I/II V600-HA
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Supply Voltage
I/O Interface Requirements
Do not impose any voltage exceeding the rated voltage range. Doing
so, or applying alternating current (100 VAC) may cause the product
to explode or burn.
1. The TRG input must be 10 ms min.
2. The INHIBIT input must be 20 ms min.
3. Minimum of 5 ms is required as the transfer time of the Read/
Write Selection Input (W/R).
Load Short-circuiting
Do not short-circuit the load connected to the product or connect to
the power supply. Doing so may cause the product to explode or
burn.
4. The read data output must be read after the Normal End Output is
set to ON.
Connecting the Sensor
Hold the black part of the connector, line up the notch and push it in
until it clicks.
Wiring
Avoid wiring mistakes such as incorrect polarity in the power supply.
Wiring mistakes may cause the product to explode or burn.
■ Correct Use
Grounding
The FG line is provided for grounding to the earth. When using the
Amplifier in an environment where it is exposed to large amounts of
noise or if the V600-HA@91/-HA@81/-HA@92 Amplifier malfunctions,
provide a Class-3 ground (ground resistance of 100 Ω or less). Note
that sharing the grounding wire with other equipment or grounding to
the beam of a building will adversely affect the grounding effect.
V600-HA91/81/92
Other equipment
Compatibility with the SRAM Memory
Type Data Carrier
1. If the Data Carrier is stationary in the transmission area for a long
time when using the V600-HA@91/81 in the AUTO mode, or when
using the V600-HAR92, it will drastically reduce the battery life.
Therefore, stop the oscillation in the sensor either by turning off
the power of the V600-HA@91/81/92 Amplifier or by setting the
Inhibit input to ON.
OK
FG
Less than 100 Ω
V600-HA91/81/92
Other equipment
2. Use a Data Carrier that has the oscillation frequency of 530 kHz.
Note that the following models manufactured before February
1991 cannot be used.
NG
FG
• V600-D2KR01
• V600-D2KR02
Less than 100 Ω
Precautions When Using the AUTO
Mode
Mounting
Amplifier Spacing
If transmitting to the Data Carrier while it is traveling under the AUTO
mode, conduct tests to make sure that the travel speed and installa-
tion conditions are fully satisfied.
When installing V600-HA@91/V600-HA@81/V600-HA@92 Amplifi-
ers in a row, provide a minimum space of 10 mm between Amplifiers
in order to prevent them from being affected by the heat produced by
each Amplifier.
10 mm min.
V600-HA91/81/92
When housing the Amplifiers in a box, provide a fan or ventilation
opening for radiating the heat.
When wiring power cables, which carry large current such as motor
drive cables, near the V600-HA@91/81/92 Amplifiers, conduct neces-
sary tests to make sure that the installation conditions are fully satis-
fied.
10
Intelligent Flag I/II V600-HA
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Amplifier
V600-HAR91/-HAR81
25
* Enlarged Section of Mounting Hole
4.4
30
Mounting Hole Dimensions
5.5
30
21
55
Two, mounting
holes
30û
6
*
2-M4
17.5
28.3
36.3
61.8
68.5
89 0.2
80
35.2
89
98
21 0.2
Vinyl-insulated round cord 5.8-mm dia.,
13-conductor cable, standard length: 0.5 m
500 mm
28.1
XG4E-2031
44.7
8.2
25
Intelligent Flag I/II V600-HA
11
Download from Www.Somanuals.com. All Manuals Search And Download.
V600-HAM91/-HAM81
25
* Enlarged Section of Mounting Hole
4.4
30
Mounting Hole Dimensions
5.5
30
21
55
Two mounting
holes *
30˚
6
2-M4
17.5
28.3
36.3
44.3
52.3
61.8
68.5
89 0.2
75
80
35.2
89
98
21 0.2
Vinyl-insulated round cord 5.8-mm dia.,
23-conductor cable, standard length: 0.5 m
500 mm
28.1
XG4E-2631
52.3
8.2
25
12
Intelligent Flag I/II V600-HA
Download from Www.Somanuals.com. All Manuals Search And Download.
V600-HAR92
25
* Enlarged Section of Mounting Hole
4.4
30
Mounting Hole Dimensions
5.5
30
21
55
Two, mounting
holes *
30˚
6
2-M4
17.5
28.3
36.3
44.3
61.8
68.5
89 0.2
75
80
35.2
89
98
21 0.2
Vinyl-insulated round cord 5.8-mm dia.,
23-conductor cable, standard length: 0.5 m
500 mm
28.1
XG4E-2631
52.3
8.2
25
Sensor
V600-HS51
2 lock washers
2 lock nuts
Vinyl-insulated round cord (4-mm dia.)
Connector
M12X1
Case: Brass
Transmission window: ABS resin
Filter: Epoxy resin
13.7 dia.
9.6 dia.
Cable: PVC (oil-resistant)
7
49.5
33
35
V600-HS61
30.5
18
4.5
8.5
12 0.2
49.5
Case: ABS resin
Filter: Epoxy resin
18
13.7 dia.
Cable: PVC (oil-resistant)
Connector
Vinyl-insulated round cord (4-mm dia.)
Detection surface
2-3.5X5
(mounting holes)
10
6.5
Intelligent Flag I/II V600-HA
13
Download from Www.Somanuals.com. All Manuals Search And Download.
V600-HS63
Two, 4.5-dia. mounting holes
Vinyl-insulated round cord 6-mm dia
2-R5
4-R1
Connector
(7/0.18-mm dia.), 8-conductor cable,
standard length: 2 m
Bushing
10
40
28
13.8 dia.
51.5
5
5
13
18
27
6
5
53
20
Power indicator (green)
23
11
Case: ABS resin
Filter: Epoxy resin
Cable: PVC (oil-resistant)
V600-HS67
Four, 4.5-dia.
mounting holes
100
0.2
90
5
5
50
50
Connector
Power indicator
(green)
25
100
13.8 dia.
0.2
90
51.5
Bushing
Vinyl-insulated round cord (6-mm dia.)
10
Case: ABS resin
Filter: Epoxy resin
Cable: PVC (oil-resistant)
14
10
30
20
11
Interface Cable
V600-A6@R (for V600-HAR91/-HAR81))
10.6
+5
+100
7.6
330
L
30
0
0
5
5
5
5
20
20
20
30
37.6
Vinyl-insulated round cord 9-mm dia
(7/0.2-mm dia.), 13-conductor cable,
standard length: 2 m
XG5M-2032-N Connector
14
Intelligent Flag I/II V600-HA
Download from Www.Somanuals.com. All Manuals Search And Download.
V600-A6@M (for V600-HAM91/-HAM81/-HAR92)
10.6
+5
+100
7.6
330
L
30
0
0
5
5
5
5
20
20
20
30
37.6
Vinyl-insulated round cord 9-mm dia (7/0.2-mm dia.),
23-conductor cable, standard length: 2 m
XG5M-2632-N Connector
Model
L (m)
V600-A60R/60M
V600-A61R/61M
V600-A62R/62M
2
5
10
Intelligent Flag I/II V600-HA
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Terms and Conditions
of all possible uses of this product, nor is it intended to imply that the
uses listed may be suitable for this product:
WARRANTY, LIMITATIONS OF
LIABILITY
WARRANTY OMRON’s exclusive warranty is that the products are
free from defects in materials and workmanship for a period of one
year (or other period if specified) from date of sale by OMRON.
• Outdoor use, uses involving potential chemical contamination or
electrical interference, or conditions or uses not described in this
catalog.
• Nuclear energy control systems, combustion systems, railroad sys-
tems, aviation systems, medical equipment, amusement machines,
vehicles, safety equipment, and installations subject to separate
industry or government regulations.
OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE
OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES
THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED
USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED.
• Systems, machines and equipment that could present a risk to life
or property.
Please know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSI-
BLE FOR SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CON-
NECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED ON CONTRACT, WARRANTY, NEGLIGENCE OR STRICT
LIABILITY.
PROGRAMMABLE PRODUCTS OMRON shall not be responsible
for the user’s programming of a programmable product, or any con-
sequence thereof.
In no event shall responsibility of OMRON for any act exceed the indi-
vidual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WAR-
RANTY, REPAIR OR OTHER CLAIMS REGARDING THE PROD-
UCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED
AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION,
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR
REPAIR.
DISCLAIMERS
PERFORMANCE DATA Performance data given in this catalog is
provided as a guide for the user in determining suitability and does
not constitute a warranty. It may represent the result of OMRON’s
test conditions, and the user must correlate it to actual application
requirements. Actual performance is subject to the OMRON War-
ranty and Limitations of Liability.
APPLICATION CONSIDERATIONS
SUITABILITY FOR USE OMRON shall not be responsible for confor-
mity with any standards, codes or regulations which apply to the
combination of the product in the customer's application or use of the
product.
CHANGE IN SPECIFICATIONS Product specifications and accesso-
ries may be changed at any time based on improvements and other
reasons. It is our practice to change part numbers when published
ratings or features are changed, or when significant construction
changes are made. However, some specifications of the product may
be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your appli-
cation. Please consult with your OMRON representative at any time
to confirm actual specifications of purchased product.
At the customer's request, OMRON will provide applicable third party
certification documents identifying ratings and limitations of use
which apply to the product. This information by itself is not sufficient
for a complete determination of the suitability of the product in combi-
nation with the end product, machine, system, or other application or
use.
ERRORS AND OMISSIONS The information in this catalog has
been carefully checked and is believed to be accurate; however, no
responsibility is assumed for clerical, typographical or proofreading
errors, or omissions.
The following are some examples of applications for which particular
attention must be given. This is not intended to be an exhaustive list
Complete terms and conditions for product purchase and use are on Omron’s website at
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
OMRON ON-LINE
OMRON ELECTRONICS LLC
One Commerce Drive
Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
847-843-7900
416-286-6465
For US technical support or other inquiries:
800-556-6766
5/03
Specifications subject to change without notice
Printed in USA
Cat. No. GC RFID 4
16
Intelligent Flag I/II V600-HA