Omnitron Systems Technology Network Card 10 100VT User Manual

LS  
its “B” backplane port to the 10/100VT facilitating a 5-port  
10/100 Ethernet switch with a fiber uplink configuration.  
LS  
fiber or UTP cables of the converter whose LED is blinking  
[Fig. 2(f)].  
OVERVIEW:  
PORT STRUCTURE:  
Fiber  
Fiber  
The iConverter 10/100VT provides 100BASE-FX fiber to  
10BASE-T or 100BASE-TX UTP conversion, as well as  
rate conversion between 10BASE-T and 100BASE-TX.  
Models are available for multimode (MM) and single-mode  
(SM) dual fiber, and single-mode single-fiber (SF).  
Using a 4-port switch design, the 10/100VT features one  
front-plane 100Mbps fiber port, one front-plane  
10/100Mbps UTP port and two 10/100Mbps Ethernet  
Backplane ports (“A” and “B”). The Backplane ports can  
connect to adjacent modules within the same chassis.  
UTP  
UTP  
(a)  
This example shows how the 10/100VT can be used as a  
managed or unmanaged media converter to create flexible  
and effective network switch configurations.  
Note that converters in SFD mode must be deployed  
in pairs.  
iConverter® 10/100VT User Manual  
Port 1 (P1)  
Switch 1 Converter A  
LS  
Converter B Switch 2  
LS  
DIP-SWITCH SETTINGS:  
Front Panel DIP-Switch Settings:  
To find out about individual chassis “A” and “B”  
backplane links, refer to the specific chassis’ user  
manual.  
The 10/100VT supports Half-Duplex and Full-Duplex  
modes and features an automatic crossover mode for  
easy attachment to hubs, switches and workstations.  
When the 10/100VT “A” and “B” Backplane ports are enabled  
(using the board-mounted “A EN” and “B EN” DIP-Switches),  
they connect via the chassis’ backplane to the slots on  
the left and right sides of the 10/100VT module. When  
another switch-based module with Backplane port  
connections such as a second 10/100VT or an NMM is  
installed in an adjacent slot, it can be connected via the  
backplane to the 10/100VT to facilitate a multi-module  
configuration.  
(b)  
Port 2 (P2)  
LINK MODES:  
In order to accommodate different user needs, the  
10/100VT supports several different linking modes.  
The 10/100VT can be used as a standard two-port UTP to  
fiber converter. It can also use its two additional  
10/100 backplane ports to connect to adjacent modules  
and accommodate flexible network configurations like  
in-band management and multi-module configurations.  
The iConverter 19-Module, 5-Module and 2-Module Chassis  
have backplanes that facilitate connectivity between  
adjacent modules.  
Switch 1 Converter A  
LP  
Converter B Switch 2  
LP  
Fig. 3 Front Panel DIP-Switches  
Fiber Full/Half-Duplex “FDX/HDX” DIP-Switch:  
Setting this DIP-Switch to Full-Duplex “FDX” facilitates  
connecting to a switch or a workstation that supports Full-  
Duplex operation. Setting this DIP-Switch to Half-Duplex  
“HDX” facilitates connecting to a hub (with a shared/non-  
switched fiber port) or a workstation that supports only  
Half-Duplex.  
iConverter 10/100VT Dual Fiber Modules  
In “Link Segment” (LS), sometimes referred to as the  
“Normal” mode, a port transmits a “Link” signal  
independently of any received “Link” at any other port.  
For example, the UTP transmits a “Link” regardless of the  
fiber receiving a “Link” [Fig. 2(a) & (b)].  
(c)  
Fiber Type /  
Distance /  
Connector Types  
10/100VT Application Example:  
ST  
SC  
MT-RJ  
LC  
-
Wavelength  
Switch 1 Converter A  
LP  
Converter B Switch 2  
RFD  
Slot 1  
Slot 2  
Slot 3  
MM / 5 km /  
1310 nm  
Chassis  
Backplane  
8800-0  
8802-0  
8804-0  
“A” Link  
“B” Link  
The 10/100VT can be used in an unmanaged or managed  
fashion. When unmanaged, it can be installed in an  
iConverter chassis without a Network Management Module  
(NMM). To be managed, an NMM module or an iConverter  
module with integrated management, such as the 10/100M,  
must be installed in the same chassis as the 10/100VT.  
In “Link Propagate” (LP), sometimes referred to as “Link  
Loss Carry Forward”, a port transmits a “Link” signal only  
when receiving a “Link” at its other port. For example, the  
UTP transmits a “Link” only when receiving a “Link” at the  
fiber port [Fig. 2(c)].  
SM / 30 km /  
1310 nm  
(d)  
UTP Auto/Manual “AN/Man” DIP-Switch:  
8801-1  
8801-2  
-
8803-1  
8803-2  
8803-3  
8805-1  
8807-1  
8807-2  
8807-3  
A Port  
A Port  
A Port  
B Port  
B Port  
Setting this DIP-Switch to UTP Auto-Negotiate “AN”  
(factory setting) enables the UTP port to determine the  
speed and duplex mode automatically. If the connected  
device cannot provide the proper signal to indicate its  
own mode of operation, the UTP Manual “Man” DIP-Switch  
setting should be used. This feature allows connections  
with devices that do not auto-negotiate properly.  
SM / 60 km /  
1310 nm  
-
-
Switch 1 Converter A  
LP  
Converter B Switch 2  
RFD+LP  
NMM  
front /  
back  
Internal  
10/100  
switch chip  
Internal  
10/100  
switch chip  
In “Remote Fault Detection” (RFD), the fiber port transmits  
a “Link” signal only when receiving a “Link” at the fiber  
port. As a result, fiber faults (no “Link” received at the  
fiber) are looped-back and can be reported to the network  
core [Fig. 2(d)].  
SM / 120 km /  
1550 nm  
Advanced Features:  
select  
(e)  
The 10/100VT features Port VLAN and Tag VLAN, which  
allow complete control of traffic flow between the fiber  
port, UTP port, and the chassis Backplane Ethernet ports  
on a module. Other advanced features include Port  
Access Control, which facilitates enabling and disabling  
of individual ports, individual Port Bandwidth Control and  
reporting of MIB statistics.  
iConverter 10/100VT Single-Fiber Modules  
SM / 20 km /  
Switch 1 Converter A  
SFD  
Converter B Switch 2  
SFD  
Tx: 1310 nm,  
Rx: 1550 nm  
-
-
-
-
8810-1  
8810-2  
8811-1  
8811-2  
-
-
-
-
-
-
-
-
UTP 10/100 DIP-Switch:  
NMM UTP  
10 port  
Fiber  
100 port  
UTP  
10/100 port  
4-port 10/100 UTP  
Switch  
In “Remote Fault Detection + Link Propagate” (RFD+LP),  
the UTP port transmits a “Link” signal only when receiving  
a “Link” at the fiber port. The fiber port transmits a “Link”  
only when receiving “Link” signals both at the fiber port  
and the UTP port. As a result, fiber faults (no “Link”  
received at the fiber) are looped-back and can be reported  
to the network core [Fig. 2(e)].  
When the UTP “AN/Man” DIP-Switch (described above) is  
in the “Man” position, the UTP 10/100 DIP-Switch  
determines the speed of operation for the UTP port.  
SM / 40 km /  
Tx: 1310 nm,  
Rx: 1550 nm  
4Tx Module  
NMM Module  
10/100VT Module  
(f)  
Fig. 1 In-Band Managed 10/100VT Application  
Setting the UTP 10/100 DIP-Switch to UTP 100Mbps “100”  
(factory setting) forces the UTP port to operate at  
100Mbps. Setting this DIP-Switch to UTP 10Mbps “10”  
forces the UTP port to operate at 10Mbps. Adjust the UTP  
10/100 DIP-Switch to match the speed of the  
connecting device.  
Fig. 1 depicts a chassis with three modules plugged into  
three of its adjacent backplane slots. The adjacent slots  
are connected via the backplane using the “A” and “B”  
10/100 links. In this example, the 10/100VT in the center  
slot connects to the slot on its left using the ”A” link and  
to the slot on its right using the “B” link.  
SM / 20 km /  
Tx: 1550 nm,  
Rx: 1310 nm  
Note that using the Advanced Features listed above  
require the use of the NMM (or an iConverter module  
with integrated management) and the NetOutlook™  
Management Software, third-party SNMP management  
software or Telnet.  
Switch 1 Converter A  
LED Lit  
Converter B Switch 2  
LED Blinking LED Off  
LED Status depends on connected device  
SM / 40 km /  
Tx: 1550 nm,  
Rx: 1310 nm  
Note that connecting two converters with both set to  
RFD mode is illegal and will cause a “deadly  
embrace” lockup.  
Fig. 2 10/100VT Link Modes  
port. As a result, fiber faults (no “Link” received at the  
fiber) are looped back and can be reported to the network  
core. In addition, connecting two back-to-back converters  
which are both set to SFD facilitates dual-loop-back where  
fiber faults are reported to both ends of the network.  
blinking fiber link LED indicates a fault of the transmit  
For more information on using and configuring the  
Advanced Features, please refer to the NetOutlook  
Management Software user manual.  
For wide temperature (-40 to 60º C), add a "W" to the end of the  
model number. Consult factory for extended temperature  
(-40 to +75º C) models.  
When using single-fiber (SF) media converter models, the Tx  
wavelength on one end has to match the Rx wavelength on the other.  
When the UTP “AN/Man” DIP-Switch is in the Auto  
Negotiate “AN” position, and the UTP 10/100 DIP-Switch  
is in the “100” position, the UTP port auto-negotiates to  
100Mbps or 10Mbps. When in the “10” position, the UTP  
port only operates at 10Mbps.  
In this example, the module on the left is a Network  
Management Module (NMM) and it connects via its “A”  
Backplane port to the 10/100VT facilitating in-band  
management (via the fiber uplink). The module on the right  
is a 4-port 10/100 switch module (4Tx) and it connects via  
In “Symmetrical Fault Detection” (SFD), the UTP port  
transmits a “Link” signal only when receiving a “Link” at  
the fiber port. The fiber port transmits a “Link” only when  
receiving a “Link” signal both at the fiber port and the UTP  
A
Page 1  
Page 2  
Page 3  
Page 4  
Page 5  
Page 6  
YEARS from the date of shipment. A LIFETIME warranty  
may be obtained by the original purchaser by  
REGISTERING this product with Omnitron within 90 days  
from the date of shipment. TO REGISTER, COMPLETE  
AND MAILOR FAXTHETHE ENCLOSED REGISTRATION  
FORM. Or you may register your product on the Internet  
Omnitron will, at its option, repair or replace a product which is  
proven to be defective. For warranty service, the product  
must be sent to an Omnitron designated facility, at Buyer’s  
expense. Omnitron will pay the shipping charge to return  
the product to Buyer’s designated US address using  
Omnitron’s standard shipping method.  
or Link Segment modes. When this DIP-Switch is in the  
left “LS” position (factory setting), Link Segment mode is  
enabled. When this DIP-Switch position is in the right “LP”  
position, Link Propagate “LP” mode is enabled. In this  
mode, the iConverter propagates the presence or absence  
of an incoming “Link” signal from one port to the other.  
UTP Full/Half Duplex “FDX/HDX” DIP-Switch:  
When the UTP “AN/Man” DIP-Switch is in the “Man”  
position, the UTP Full/Half-Duplex DIP-Switch determines  
the duplex operation mode for the UTP port.  
RJ45 Crossover “=/X” Switch (not shown):  
10/100VT LED INDICATORS:  
Model Type  
Protocols  
10/100VT  
Although the 10/100VT features auto-crossover, some  
devices may have problems completing the link. When  
connecting the UTP to a hub or switch, set this switch to  
SWITCH “X” (factory setting). When connecting to a  
workstation, set to CROSSOVER “=”.  
LED Function  
"Legend"  
Color  
Off state  
On / blinking state  
100BASE-FX, 10BASE-T, or  
100BASE-TX  
(1536 bytes max. frame size)  
Power "Pwr"  
Amber No power  
Half-Duplex when  
fiber link is active Full-Duplex when  
Module has power  
Setting the UTP Full/Half-Duplex DIP-Switch to UTP  
Full-Duplex “FDX” (factory setting) position forces the  
UTP port to operate in Full-Duplex. Setting this DIP-Switch  
to UTP Half-Duplex “HDX” forces the UTP port to operate  
in Half-Duplex. Adjust the UTP Half/Full-Duplex  
DIP-Switch to match the connecting device.  
Fiber Port  
duplex  
"FDX"  
Copper  
Connectors  
Note that for Link Segment mode, the “LP”, “RFD”  
and “SFD” DIP-Switches must be in the Left or “Off”  
position (factory default).  
MOUNTING AND CABLE ATTACHMENT:  
iConverter modules are hot-swappable and can be  
installed into any chassis in the iConverter family.  
Green  
(has no meaning  
when fiber link is  
not active)  
link fiber is active  
RJ-45  
Fiber  
Connectors  
SC, ST, LC, MT-RJ,  
Single-Fiber SC  
Fiber Port  
link/activity  
"Lk/Act"  
On: Fiber link  
Blinking: Fiber data  
transmission  
Note that setting both “LP” and “SFD” link mode  
DIP-Switches (or setting both “RFD” and “SFD” link  
mode DIP-Switches) to the Right position on the  
same module is an illegal mode that will result in  
Link Segment behavior.  
1. Carefully slide the iConverter module into the  
installation slot, aligning the module with the  
installation guides. Ensure that the module is firmly  
seated against the backplane.  
Green No fiber link  
When the UTP “AN/Man” DIP-Switch is in the Auto  
Negotiate “AN” position, and the UTP Full/Half Duplex  
DIP-Switch is in the Full-Duplex “FDX” position, the UTP  
port auto-negotiates to Full or Half-Duplex. When in the  
Half-Duplex “HDX” position, the UTP port functions only  
in Half-Duplex.  
UTP X-over, LS/LP, RFD, BP  
Enable, SFD, Auto/Man,  
10/100, FDX/HDX  
Limitation of Warranty  
Backplane link/activity (not installed, used in NetOutlook  
)
Controls  
The foregoing warranty shall not apply to defects resulting  
from improper or inadequate use and/or maintenance of  
the equipment by Buyer, Buyer-supplied equipment,  
Buyer-supplied interfacing, unauthorized modifications or  
tampering with equipment (including removal of equipment  
cover by personnel not specifically authorized and certified  
by Omnitron), or misuse, or operating outside the  
environmental specification of the product (including but  
not limited to voltage, ambient temperature, radiation,  
unusual dust, etc.), or improper site preparation or  
maintenance. No other warranty is expressed or implied.  
Omnitron specifically disclaims the implied warranties of  
merchantability and fitness for any particular purpose.  
Manual mode  
(reflects state of the mode (reflects state  
DIP-switch)  
Auto-negotiation  
UTP Port Auto-  
Negotiate "AN"  
Green  
Green  
2. Secure the module by securing the panel fastener  
screw (attached to module) to chassis front.  
Power, FO link, UTP link,  
Auto, FDX/HDX, 10/100  
Remote Fault Detection “RFD” DIP-Switch:  
When in the right switch position, the Remote Fault  
Detection “RFD” mode is enabled. In RFD mode, the  
10/100VT propagates the presence or absence of an  
incoming “Link” signal from a Fiber port receive side to  
the transmit side of the Fiber port.  
of the DIP-Switch)  
LED Displays  
100Mbps not  
selected when UTP 100Mbps selected  
link is active (has when UTP link is  
no meaning when active  
UTP link is not  
active)  
Board Mounted DIP-Switch Settings:  
3. Attach the UTP port via a category 5 cable to a  
10BASE-T or 100BASE-TX Ethernet device.  
Dimensions  
Weight  
W:0.85" x D:4.5" x H:2.8"  
8 oz.  
UTP Port 100  
Mbps "100"  
= A Port Backplane Enabled  
= B Port Backplane Enabled  
= Link Propagate/Link Segment  
= Remote Fault Detection  
A EN  
B EN  
LP  
4. Attach the fiber port via an appropriate multimode or  
single-mode fiber cable to a 100Base-Fx Fast  
Ethernet device. The iConverter transmit (Tx) must  
attach to the receive side on the other device; the  
receive (Rx) must attach to the transmit.  
When this DIP-Switch is in the right “RFD” position and  
the “LS/LP” DIP-Switch is in the right “LP” position, Remote  
Fault Detection + Link Propagation mode is enabled. In  
“RFD+LP” mode, the 10/100VT propagates the presence  
or absence of an incoming “Link” signal from a Fiber port  
receive side to the transmit side of both the Fiber and the  
UTP ports.  
10Mbps not  
selected when UTP 10Mbps selected  
Compliance  
UL, CE, FCC Class A  
RFD  
SFD  
TEST = Reserved for factory use  
= Symmetrical Fault Detection  
UTP Port 10  
Mbps "10"  
link is active (has  
when UTP link is  
Power  
Requirement  
Green  
Green  
0.7A @ 3.3VDC (typical)  
no meaning when active  
UTP link is not  
active)  
5. When using single-fiber (SF) media converter models,  
the Tx wavelength on one end has to match the Rx  
wavelength on the other. Note that based on this  
guideline the SF media converter models must be used  
in pairs, such as the 8810-1 matched with the 8811-1.  
Exclusive Remedies  
Fig. 4 Board Mounted DIP-Switches  
Standard: 0 to 50º C  
Wide: -40 to 60º C  
Storage: -40 to 80º C  
The remedies provided herein are the Buyer’s sole and  
exclusive remedies. Omnitron shall not be liable for any  
direct, indirect, special, incidental, or consequential  
damages, whether based on contract, tort, or any legal  
theory.  
Half-Duplex when  
UTP link is active Full-Duplex when  
(has no meaning  
when UTP link is  
not active)  
A Port Backplane Enabled “A EN” DIP-Switch:  
When the “A EN” DIP-Switch is in the left position (factory  
default), the 10/100VT module’s Backplane Ethernet A  
port is isolated from the backplane. When the “A EN”  
DIP-Switch is in the right position, the 10/100VT module’s  
Backplane Ethernet A port is enabled. This port allows  
connectivity to an adjacent module.  
Temperature  
UTP Port Duplex  
"FDX"  
UTP link is active  
Connecting two converters with both set to RFD  
mode is illegal and will cause a “deadly embrace”  
lockup.  
Humidity  
Altitude  
5 to 95% (non-condensing)  
-100m to 4000m  
910,000  
Note that when hot-swapping a 10/100VT module  
(removing it from the chassis and reinserting it), a period  
of three seconds must pass between removing and  
reinserting the module.  
UTP port  
link/activity  
"Lk/Act"  
On: UTP link  
Blinking: UTP data  
transmission  
Symmetrical Fault Detection “SFD” DIP-Switch:  
When in the right switch position, the Symmetrical Fault  
Detection “SFD” mode is enabled. In this mode, two  
10/100VT media converters can be deployed in tandem  
so that the absence of an incoming “Link” signal to any  
port on either media converter forces the absence of a  
“Link” signal on all other ports of both media converters.  
Green No UTP link  
TECHNICALSUPPORT:  
For help with this product, contact our Technical Support:  
MTBF (hrs)  
Note: UTP 100Mbps, UTP 10 Mbps and UTP duplex are forced  
when in manual mode and what is agreed to by the link partner  
when in Auto-Negotiate mode.  
B Port Backplane Enabled “B EN” DIP-Switch:  
When the “B EN” DIP-Switch is in the left position (factory  
default), the 10/100VT module’s Backplane Ethernet B  
port is isolated from the backplane. When the “B EN”  
DIP-Switch is in the right position, the 10/100VT module’s  
Backplane Ethernet B port is enabled. This port allows  
connectivity to an adjacent module.  
Phone:  
(949)250-6510  
UPDATING 10/100VT FIRMWARE:  
Warning  
Fax:  
(949)250-6514  
Updating the 10/100VT firmware requires an NMM to be  
installed in the same chassis. The new 10/100VT firmware  
is uploaded to the NMM’s FTP server and then installed in  
the 10/100VT.  
The operating description in this Instruction Manual is for  
use by qualified personnel only. To avoid electrical shock,  
do not perform any servicing of this unit other than that  
contained in the operating instructions, unless you are  
qualified and certified to do so by Omnitron Systems  
Technology, Inc.  
Address: Omnitron Systems Technology, Inc.  
140 Technology Dr., #500  
Irvine, CA 92618 USA  
Factory Test “TEST” DIP-Switch:  
This DIP-Switch is for factory use only and must always  
be left in the left position (factory default).  
Email:  
URL:  
For more information on updating the 10/100VT  
firmware, please refer to the NMM user manual.  
Link Propagate/Link Segment “LP” DIP-Switch:  
This DIP-Switch controls the selection of Link Propagate  
Warranty  
Form: 040-08800-001G 9/07  
Page 12  
This product is warranted to the original purchaser against  
defects in material and workmanship for a period of TWO  
Page 7  
Page 8  
Page 9  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Clothes Dryer T1570C User Manual
Miller Electric Welder PipePro Dual User Manual
NEC DVD Player NDV 28 User Manual
NextBase CRT Television TV700 User Manual
Niles Audio TV Video Accessories C5 RFWM User Manual
Olympus Camera Lens VE867302 User Manual
Olympus Microcassette Recorder 145025 User Manual
Onkyo Musical Table RBX 500 User Manual
Panasonic Camcorder AG AC130AP User Manual
Panasonic Fax Machine KX FM255 User Manual