1. SAFETY INFORMATION ................................................................................................ 1
2. SPECIFICATION............................................................................................................. 2
2-1 General Specification ........................................................................................... 2
3. PARTS & CONTROLS.................................................................................................... 6
3-1 The Name of Each Parts and Positions................................................................ 6
3-2 Power Status........................................................................................................ 9
3-3 Quick Manual for Easy Set-up.............................................................................. 9
3-4 ACV、DCV and DCA Test Setting.......................................................................... 9
3-5 UNIT Setting Step .............................................................................................. 10
3-6 ALARM Setting Step........................................................................................... 10
3-7 Real Time Clock , Time/ Date Setting Step ........................................................ 11
3-8 Record/Print Start Time, Stop Time, Interval Time Setting Step......................... 11
3-9 Print Mode Setting Step...................................................................................... 12
3-10 Clear Record Step............................................................................................ 12
3-11 Disable Start、Stop、Intv and Setting Step.................................................... 12
3-12 Decimal Point Setting Step............................................................................... 12
3-13 Consecutive Record and Print Setting Step ..................................................... 12
3-14 Reset System Setting Step............................................................................... 12
3-15 Record / Print Start and Step Operation Method.............................................. 13
3-16 Memory Full Warning. ...................................................................................... 13
3-17 Alarm Print in Graphic Mode ............................................................................ 13
3-18 Scale Change in Graphic Mode........................................................................ 14
Download from Www.Somanuals.com. All Manuals Search And Download.
3-19 How to ConnectsTL-(A37) Analog Output Cable.............................................. 14
3-20 Setup Process Transducer (4-20mA) Mode ..................................................... 15
4. BATTERY & FUSE REPLACEMENT ........................................................................... 16
4-1 Battery Check & Replacement ........................................................................... 16
4-2 Fuse Replacement ............................................................................................. 16
4-3 Note.................................................................................................................... 16
5. DATALOGGING ............................................................................................................ 16
5-1 Software Installation........................................................................................... 17
5-2 Default Settings.................................................................................................. 21
5-3 Meter Stand alone Operation ............................................................................. 36
5-4 Download Datalogger (Graphic Recorder
PC)............................................... 38
5-5 Data Conversion................................................................................................. 41
5-6 On-Line Operation with PC................................................................................. 45
Download from Www.Somanuals.com. All Manuals Search And Download.
1. SAFETY INFORMATION
ꢀ
Read the following safety information carefully before attempting to operate
or service the meter.
ꢀ The meter analog input protection voltage range is 24V ,current
range is 250V/0.5A Fuse(MAX) , maybe damage forever if overload.
Environment conditions
:
ꢁ
ꢂ
ꢃ
Altitude up to 2000 meters
Indoor use
Relatively humidity 10~80%RH
Operation temperature 0
〜
40℃
(32~104℉)
Maintenance & Clearing
ꢁ Repairs or servicing not covered in this manual should only be
performed by qualified personnel.
ꢂ Periodically wipe the case with a dry cloth. Do not use abrasives or
solvents on this instruments.
Do not use abrasives or solvents on this instruments.
Safety symbols
:
Meter is protected throughout by double insulation or
reinforced insulation.
Comply with EN-61010-1
1
Download from Www.Somanuals.com. All Manuals Search And Download.
2. SPECIFICATION
2-1 General Specification
1
Display : 3 LCD
2
LCD symbols:
1
3
4
2 24 26 5
6
7
16
8
18
11
17
15
12
13
21
19
28
20
10 23 14 9
25 27 22
(Fig-1)
1. SET
In setting mode symbol.
:
:
:
:
2. RS-232
DATE
In RS-232 transmission mode symbol.
Show the date of real time clock.
Show mode : month – day – year.
3.
–
–
:
TIME
Show the time of real time clock.
Show mode is hour : minute : second.
4.
5.
:
START
Show the start time of record / print.
:
Show mode is hour : minute : second.
:
:
2
Download from Www.Somanuals.com. All Manuals Search And Download.
STOP
Show the stop time of record / print.
Show the interval time of record / print.
:
:
6.
7.
:
:
:
INTV
:
8.
9.
:DC test symbol.
:AC test symbol.
10.
:Low battery indicator.
:Analog test indicate unit.
:The printer working in the graphic mode.
11. mVA
12. G
13. T
:The printer working in the text mode.
14. ꢀ
15. MAX
16. MIN
17. LUX
18. Fc
:Memory record indicator.
:MAX Analog input indicator.
:MIN Analog input indicator.
:LUX unit indicator.
:Feet-candle unit indicator.
:dB unit indicator.
19. dB
20. %RH
:Relative Humidity %RH unit indicator.
21.
:
Printer in using indicator
.
22.
23.
.
:
LCD.
7 segments to show the read value and decimal point of
:Negative polarity.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
24. HI ALARM
25. LO ALARM
26. HiHi ALARM
27. LoLo ALARM
:
Hi alarm indicator
Lo alarm indicator
Hi Hi alarm indicator
Lo Lo alarm indicator
Temperature unit indicator.
.
:
.
:
.
:
.
28. ℃ ,℉
:
-
29. Over Load Indicator :Show
Other parts:
or
。
Input Protection
:Voltage range 24V ,current range 0.5A/250V
Fuse(MAX)
Operation Temperature:0℃〜40℃( 32℉〜104℉ ) & (10~ 80% RH)
and Humidity
Conserve Temperature:-10℃〜60℃(14℉〜140℉) & (10~70% RH)
and Humidity
Dimensions
Weight
:About 250 (L) × 100 (W) × 45(H) mm
:About 500g with battery
Printer
:ꢁInterval print :
00 hour : 00 minute : 03 second〜23 hour :
59 minute : 59 sec
ꢂTrigger print : Print three data
(date / time / Reading)
Accessories
:Thermo carrying case, Test leads with alligator
clip, 2 rolls of thermo paper, 110V/220V AC to 9V
DC power adapter/power cord, RS-232 cable, P.C.
software disk, 6pcs 1.5V AA batteries, TL-A37
analog output cable, RS-232 convert header,
Operation manual.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
2-2 Electrical Specification
Analog test range :DCV/ACV:2V,200mV
DCA: 20mA
Accuracy
:(at 23℃±5℃,below 80%RH)
DC (M1%rdg+3dgts)
AC (M1%rdg+5dgts) at (50~450Hz)
Resolution
:200mV/2V range is 0.1mV/1mV
20mA range is 0.01mA
A / D Sample Rate :2.5 times/sec
Power Source
:6 pcs 1.5V,# 3 battery or 9V, DC adaptor
(inside negative, outside positive)
Battery Life
Printer
:Approx. 100 hours (without printing)
:Thermal printer (EPL1902 of Panasonic)
MEMORY
:60000 records (up to 130000 records)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
3. PARTS & CONTROLS
3-1 The Name of Each Parts and Positions:
200mV
¢CX ¢FX
HiHi
2V
Lux Fc
Hi
200mV
dB
LoLo
2V
20mA
¢XRH
A
A
¢X
Lo
G
T
DATE
TIME
START
STOP
INTV
0
,
1
2
3
4
5
6
7
8
9
3 SETTING
RANGE
UNIT
FEED
LINE
MAX
MIN
SETUP
CLOCK
ALARM
PRINT
,
RECORD
1 TRIGGER
,
3 CONSECUTIVE
m A
COM
V
20mA
MAX
60V
24V
MAX
FUSED
600V
(Fig-2)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
200mV
C / F
HiHi
Toggle button for ( 200mV, ℃/℉, HiHi, DATA)
and digit “ o ”.
1.
2.
DATA
0
2V
Lux/Fc
Hi
Toggle button for ( 2V, Lux/ Fc, Hi, TIME) and
digit “ 1/2/3 ”.
TIME
1/2/3
200mV
dB
LoLo
Toggle button for ( 200mV, dB, LoLo, START)
and digit “ 4/5/6 ”.
3.
START
4/5/6
2V
%RH
Lo
Toggle button for ( 2V, %RH, Lo, STOP) and
digit “ 7/8/9 ”.
4.
5.
STOP
7/8/9
20mA
A/
G/T
INTV
Toggle button for (
20mA,
A /
A,
G / T, INTV ) button and “
function.
” right shift
3'SETTING
Press and hold this button for 3 sec will into
setting mode, press again will end setting
mode.
6.
SETUP
7
Download from Www.Somanuals.com. All Manuals Search And Download.
RANGE
Feed paper in normal mode, range function in
setting mode.
7.
8.
FEED
LINE
UNIT
MAX/MIN function in normal mode “ UNIT ”
function in setting mode.
MAX
MIN
In normal mode, press 1 sec is trigger print
function, press and hold for 3 sec is start/stop
consecutive print function, but in setting mode
will be “ clock ” function.
CLOCK
PRINT
9.
In normal mode, press 1 sec is trigger record (
MAX 255 times), In setting mode is “ alarm ”
function, press and hold over 3 sec is start/stop
consecutive record function.
ALARM
ꢀ
10.
RECORD
Power button.
11.
12
“ COM ” Measuring
Socket
To connect negative lead of voltage, current.
(black color)
“ V ” Measuring
Socket
13
14
To connect positive lead for voltage.(red color)
To connect positive lead for current.
“ mA ” Measuring
Socket
15 LCD
Show test value, unit symbol and range indicator.
Printing data.
16 Thermal Printer
17 Acryl
Putting thermal paper.
RS-232 Connector
18
RS-232 used.
19 FEED Button
20 DC 9V Socket
Feed paper into printer
To connect adaptor.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
3-2 Power Status :
As battery power is not sufficient, the
, will be shown on LCD
replace with six new 1.5V batteries is required.
3-3 Quick Manual for Easy Set-up
STEP1
STEP2
STEP3
STEP4 STEP5
Press to
Reconfirm
Choose one from specified
function Bar.
Push
button 3 second.
this
Select one.
return
input setting.
normal.
2V
200mV
20mA
A /
200mV
2V
RANGE
RANGE
F
LUX / FC
A
c
dB
%RH
UNIT
UNIT
CLOCK
ALARM
SETUP
SETUP
STOP INTV
TIME START
LoLo
DATE
HiHi
CLOCK
ALARM
Hi
Lo
G / T
a. You could only set up one of the functions at each time.
b. To change position of point decimal, follow step1 & step2, then press button.
c. To input digit, follow step1 & step3 to set the number.
3-4 ACV、DCV and DCA Test Setting :
3'SETTING
1. ACV 2V Test setting sequence:Press and hold
for 3 sec
RANGE
RANGE
2V
ꢃ press
3'SETTING
ꢃ press
, to end setting mode.
ꢃ press
ꢃ press
3'SETTING
2. ACV 200mV Test setting sequence:Press and hold
for 3
ꢃ
200mV
RANGE
RANGE
sec ꢃ press
ꢃ press
, to end setting mode.
ꢃ press
3'SETTING
press
3'SETTING
3. DCV 2V Test setting sequence:Press and hold
for 3 sec
RANGE
RANGE
2V
ꢃ press
3'SETTING
ꢃ press
ꢃ press
ꢃ press
, to end setting mode.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
3'SETTING
4. DCV 200mV Test setting sequence:Press and hold
for 3
ꢃ
RANGE
RANGE
200mV
sec ꢃ press
ꢃ press
, to end setting mode.
ꢃ press
3'SETTING
press
3'SETTING
5. DCA 20mA Test setting sequence:Press and hold
for 3
RANGE
RANGE
20mA
sec ꢃ press
press
ꢃ press
, to end setting mode.
ꢃ press
ꢃ
3'SETTING
3-5 UNIT Setting Step:
3'SETTING
1. ℃/℉ Setting step:press and hold
for 3 sec ꢃ press
UNIT
UNIT
C/ F
ꢃ press
change℃/℉ ꢃ press
ꢃ
3'SETTING
press
, to end setting mode.
3'SETTING
2. Lux/Fc Setting step:press and hold
for 3 sec ꢃ press
UNIT
Lux/Fc
UNIT
ꢃ press
change Luc/Fc ꢃ press
ꢃ
3'SETTING
press
, to end setting mode.
3'SETTING
3. dB Setting step:press and hold
for 3 sec ꢃ press
3'SETTING
UNIT
dB
UNIT
ꢃ press
to end setting mode.
ꢃ press
ꢃ press
,
3'SETTING
4. %RH Setting step:press and hold
for 3 sec ꢃ press
3'SETTING
UNIT
%RH
UNIT
ꢃ press
to end setting mode.
ꢃ press
ꢃ press
,
3'SETTING
5.
/
A Setting step:press and hold
for 3 sec ꢃ press
UNIT
UNIT
ꢃ press change
, to end setting mode.
A/ A ꢃ press
ꢃ press
3'SETTING
3-6 ALARM Setting Step:
3'SETTING
1. HIHI ALARM Setting step:press and hold
for 3 sec ꢃ
ALARM
HiHi
press
ꢃ press
ꢃ assort 0~9 number right
ALARM
3'SETTING
shift button setting “ALARM" ꢃ press
to end setting mode.
ꢃ press
,
3'SETTING
2. HI ALARM Setting step:press and hold
ALARM
for 3 sec into setting
Hi
mode ꢃ press
ꢃ press
ꢃ assort 0~9 number
10
Download from Www.Somanuals.com. All Manuals Search And Download.
ALARM
right shift button setting “ALARM" ꢃ press
ꢃ press
3'SETTING
, to end setting mode.
3'SETTING
3. LOLO ALARM Setting step:press and hold
for 3 sec into
ALARM
LoLo
setting mode ꢃ press
ꢃ press
ꢃ assort 0~9
ALARM
number right shift button setting “ALARM" ꢃ press
ꢃ
3'SETTING
press
, to end setting mode.
3'SETTING
4. LO ALARM Setting step:press and hold
for 3 sec into
ALARM
Lo
setting mode ꢃ press
ꢃ press
ꢃ assort 0~9
ALARM
number right shift button setting “ALARM" ꢃ press
ꢃ
3'SETTING
press
, to end setting mode.
3-7 Real Time Clock , Time/ Date Setting Step:
1. Real time clock , date setting step:press and hold
CLOCK
3'SETTING
for 3
ꢃ
DATE
sec into setting mode ꢃ press
ꢃ press
assort 0~9number right shift button setting date ꢃ press
CLOCK
3'SETTING
ꢃ press
, to end setting mode.
3'SETTING
2. Real time clock, time setting step:press and hold
for 3
ꢃ
CLOCK
TIME
sec into setting mode ꢃ press
ꢃ press
assort 0~9number right shift button setting time ꢃ press
CLOCK
3'SETTING
ꢃ press
, to end setting mode.
3-8 Record/Print Start Time, Stop Time, Interval Time Setting Step:
3'SETTING
1.Start time setting step:press and hold
for 3 sec into
CLOCK
START
setting mode
number
press
ꢀ
press
ꢀ
press
ꢀ
CLOCK
assort 0~9
3'SETTING
right shift button setting start time
ꢀ
press
ꢀ
to end setting mode.
3'SETTING
2.Stop time setting step:press and hold
for 3 sec into
CLOCK
STOP
setting mode
0~9number
press
ꢀ
press
ꢀ
press
ꢀ
CLOCK
assort
right shift button setting stop time
to end setting mode.
ꢀ
press
ꢀ
3'SETTING
3'SETTING
3. Interval time setting step:press and hold
for 3 sec into
CLOCK
INTV
setting mode ꢃ press
ꢃ press
ꢃ assort 0~9
CLOCK
number right shift button setting interval time ꢃ press
ꢃ
11
Download from Www.Somanuals.com. All Manuals Search And Download.
3'SETTING
press
to end setting mode.
3-9 Print Mode Setting Step:
Printer work mode setting sequence:press and hold
ALARM
3'SETTING
for 3
G/T
sec into setting mode ꢃ press
ꢃ press
change
3'SETTING
G/T MODE ꢃ press
, to end setting mode.
3-10 Clear Record Step:
ꢀ
+
Press
Power ON in the same time
RECORD
The LCD should display “dEL”
3-11 Disable Start、Stop、Intv and Setting Step:
1.Disable START、STOP、INTV sequence:press and hold
START
3'SETTING
for 3 sec into setting mode ꢃ press
disable
3'SETTING
start, stop, intv ꢃ press
to end setting mode.
3'SETTING
2.Disable ALARM sequence:press and hold
for 3 sec into
3'SETTING
STOP
setting mode ꢃ press
disable alarm ꢃ press
to end setting mode.
3-12 Decimal Point Setting Step:
3'SETTING
Shift point setting sequence:press and hold
for 3 sec to
INTV
enter setting mode ꢃ press
position ꢃ press
to change decimal point
3'SETTING
to end setting mode.
3-13 Consecutive Record and Print Setting Step:
3'SETTING
Setting sequence:press and hold
for 3 sec to enter setting
TIME
3'SETTING
mode ꢃ press
end setting mode.
setting
/ ꢀ ꢃ press
, to
TIME
※ If already in setting MODE, press
button only.
3-14 Reset System Setting Step:
3'SETTING
Press
+
Power ON
12
Download from Www.Somanuals.com. All Manuals Search And Download.
3-15 Record / Print Start and Step Operation Method:
(1). Start way :
ꢀ
PRINT
RECORD
1. Trigger Record / Print : in general mode press
or
one second.
2. Consecutive Record/Print :
ꢀ
Automatic mode :
a). Into setting mode, setting Start/Stop/Into/Time.
b). Chose automate consecutive Record/Print (by 3-13 setting
way)
c). Back to general mode, on LCD ꢀ or
should be
repeat.
ꢁ
Hand setting mode :
a). Into setting mode, disable Start, Stop, Intv. (by 3-11 stop
way)
b). Into setting mode, setting Intv.
c). Back to general mode.
ꢀ
PRINT
RECORD
d). Press
button 3 second, the LCD will be show
ꢀ or
symbol, into consecutive Record / Print of hand
setting mode.
(2). End Record/Print :
1. Automatic mode : The function will be stopped automatically while
the STOP time is up.
2. Hand setting mode :To stop consecutive Record/Print by user press
ꢀ
ꢀ
PRINT
RECORD
RECORD
and hold
or
button for 3 seconds. The LCD
or
PRINT
symbol will be disappear.
3-16 Memory Full Warning :
The ꢀ symbol will be flash.
3-17 Alarm Print in Graphic Mode :
When printing in G mode, if you have setting any alarm points
(HiHi, Hi, LoLo, Lo) when the read value over the set points, the
printer the will print alarm value on the paper.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
3-18 Scale Change in Graphic Mode
HiHi
Hi
Lo
LoLo
Scale change by alarm setting
ALARM ALARM ALARM ALARM
4
No change
4
4
4
No change
No change
No change
4
4
4
4
Change scale by HiHi Hi ALARM
Change scale by HiHi Lo ALARM
Change scale by HiHi LoLo ALARM
Change scale by Hi Lo ALARM
Change scale by Hi LoLo ALARM
Change scale by Lo LoLo ALARM
Change scale by HiHi Lo ALARM
Change scale by HiHi LoLo ALARM
Change scale by HiHi LoLo ALARM
Change scale byHi LoLo ALARM
Change scale by HiHi Lo ALARM
No setting ALARM, no change
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4 : had setting
3-19 How to ConnectsTL-(A37) Analog Output Cable
14
Download from Www.Somanuals.com. All Manuals Search And Download.
200mV
¢C ¢FX
HiHi
2V
Lux Fc
Hi
200mV
dB
LoLo
2V
20mA
X
¢XRH
A
A
¢X
Lo
G
T
DATE
TIME
START
STOP
INTV
0
1
2
3
4
5
6
7
8
9
,
3 SETTING
RANGE
UNIT
FEED
LINE
MAX
MIN
SETUP
CLOCK
ALARM
PRINT
,
RECORD
1
TRIGGER
,
3
CONSECUTIV
E
m A
COM
V
20mA
60V
24V
M
A
X
FUSED
M
A
X
600V
Model Connecting way (DC Input) Connecting way (AC Input)
Red lead connect to (V),
Remark
TES-1300
TES-1302
TES-1303
TES-1332
TES-1334
TES-1350
TES-1351
TES-1352
TES-1353
TES-1360
No (AC input)
No (AC input)
No (AC input)
No (AC input)
No (AC input)
Black lead connect to (COM)
Red lead connect to (V),
Black lead connect to (COM)
Red lead connect to (V),
Black lead connect to (COM)
Red lead connect to (V),
Black lead connect to (COM)
Red lead connect to (V),
Black lead connect to (COM)
Red lead connect to (V),
White lead connect to (V),
Black lead connect to (COM)
White lead connect to (V),
Black lead connect to (COM)
White lead connect to (V),
Black lead connect to (COM) terminal difference
White lead connect to (V), AC,DC output
Black lead connect to (COM) terminal difference
White lead connect to (V),
Black lead connect to (COM)
AC,DC output
terminal same
AC,DC output
terminal same
AC,DC output
Black lead connect to (COM)
Red lead connect to (V),
Black lead connect to (COM)
White lead connect to (V),
Black lead connect to (COM)
White lead connect to (V),
Black lead connect to (COM)
Red lead connect to (V),
Black lead connect to (COM)
3-20 Setup Process Transducer (4-20mA) Mode :
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation way :
INTV
Press
+ Power ON into Process Transducer (4 - 20 mA) mode.
First of all, setting Ref1 “ MAX ” reference value (the “MAX” symbol will be flash),
then press
button to input “ MAX ” reference
0 1/2/3 4/5/6 7/8/9
ꢀ
RECORD
0.001 ~ 9999, press
button and wait for speaker sound. Then
the process transducer (4 - 20mA) mode setting is success.
Ref1-0
P
16
“ LCD ” display value:
(A/D Reading-4) = “ LCD ” display value
※
Available for (4mA ~ 20mA) transducer only.
4. BATTERY & FUSE REPLACEMENT
4-1 Battery Check & Replacement:
1. As battery power is not sufficient, the
, will be shown on LCD
replace with six new 1.5V batteries is required.
2. a). Disconnecting test leads.
b).Turning off multimeter with screw-driver.
c). Open battery cover.
d). Replace the batteries
e). Cover and secure the battery cover.
4-2 Fuse Replacement:
a). Disconnecting test leads.
b). Turn off multimeter.
c). Open fuse cover with screw-driver.
d). Remove old fuse and replace with new fuse.
e). Cover and secure the fuse cover.
※ Only 5ψ×20mm fast blow type fuse is allowable.
4-3 Note:
To prevent electrical hazard or shock, turn off multimeter and disconnect
test leads before removing any cover.
5. DATALOGGING
16
Download from Www.Somanuals.com. All Manuals Search And Download.
5-1 Software Installation:
1. PC Hardware requirements:
ꢀ HDD 20 MB space, 1.44MB floppy driver, serial ports, 486 PC or above,
with COM1, COM2 comports.
ꢀ EGA or higher display.
ꢀ 4M bytes or more memory size.
2. Hardware installation :
ꢁ Switch off all power related to your PC.
ꢂ Connect the female socket of RS-232 cable to PC’s COM1 or COM2.
2
00
mV
2
V
20
0mV
2V
20mA
¢XC
H
¢
Hi
F
X
Lu
x
Fc
d
Lo
B
Lo
¢X
L
R
o
H
A
G
A
¢X
i
Hi
T
D
ATE
TIME
S
TART
STOP
INTV
0
1
2
3
4
5
6
7
8
9
,
3
SETTING
RANGE
UNIT
FEED
M
MI
AX
N
SETUP
L
IN
E
CLOCK
A
L
A
RM
PRIN
T
RECORD
RIGGER
,
1
T
,
3
CONSECU IV
T
E
m A COM
V
2
0m
A
60V
M
A
X
24V
FUS
ED
M
A
X
6
00
V
ꢄ Power on.
Connect the male socket of RS-232 cable to Graphic Recorder.
3. Software setup:
ꢁ Before setting up software of Graphic Recorder start up windows
95/98 operating system.
ꢂ Close all application.
ꢄ Insert the installation diskette into drive A: or drive B:.
Click “ Start ” from Start menu, move mouse pointer to “ Run ”, then click this button.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
!
A “ Run ” window appears, then type A:\SETUP or B:\SETUP and press “ OK ”.
" Setup program will run automatically.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
"
"
#
Click “NEXT”
$
a). Click “ NEXT ” or
b). If willing to set up on a different folder, click “ Browse ”.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
5-2 Default Settings :
1. Start up
ꢁ Run the Graphic Recorder software :
Click “Start” from the “Start” menu, move mouse pointer to “Programs”
and then move to “Omega” (Default Settings). Move mouse pointer to
“GRAPHER” and then click this button.
ꢂ Move mouse pointer to available comport COM1, COM2 then click.
2. RS232 settings
ꢁ Baud rate : 9600
ꢂ Parity : None
ꢄ Data bits : 8
Stop bit : 1
21
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Time Setup : Move mouse pointer to “System Time Set” then click this button
to input time of PC to the Graphic Recorder.
When “WAIT” (center) disappeared, setup of time is completed.
Also could be set up by “Setup” mode. Refer to P.31
4. Memory size : If you have bought more memories :
ꢀ
for more details.
ꢁ Move mouse pointer to “Option” then click. Move mouse pointer to
“Memory” and then click this button.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ In the window “MEMORY”, move mouse pointer to “UPDATE” and then
click this button. Input the No.s of IC, and then press OK.
5. ID CODE Setup :
ꢁ Move mouse pointer to “Option” then click. Move mouse pointer to
“Memory” and then click this button.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ In the window of “MEMORY” , double click or drag the mouse to
highlight the values of “ID Code”.
ꢄ Input the expected values of “ID Code” and then click the button
“ID Code”.
While “PLEASE WAIT” disappeared, setup of “ID Code” is completed.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Setup of sampling rate of the meter :
ꢁ Move mouse pointer to “Option” then click. Move mouse to “Setup” and
then click this button.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ In the window “SETUP”, select the option button named “CLOCK” under
the title “MODE”.
ꢄ Drag mouse to highlight the values of “INTERVAL”.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Input the expected values with “HOUR” , “MINUTE” , “SECOND” of
“INTERVAL” then click “SETUP”.
! While the message “Start/Stop REC/PRT with timing ? ” appears, press
“Cancel” at this moment then escape Setup mode.
7. Setup of Input Voltage \ Current
27
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢁ Move mouse pointer to “Option” then click. Move mouse pointer to
“Setup” and click this button.
ꢂ In the window “SETUP”, select the option button named “RANGE”
under the title “MODE”. Under the “RANGE” title, select the expected
input Voltage \ Current then escape “SETUP” mode.
8. Setup of Unit
ꢁ Move mouse pointer to “Option” then click. Move mouse pointer to
“Setup” and click this button.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ In the window “SETUP”, select the option button named “UNIT” under
the title “MODE”. Under the “UNIT” title, select the expected input unit
then escape “SETUP” mode.
9. Setup of Alarm :
ꢁ Move mouse pointer to “Option” then click. Move mouse pointer to
“Setup” and click this button.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ In the window “SETUP”, select the option button named “ALARM” under
the title “MODE”. Under the “ALARM” title, drag mouse to highlight the
values of HiHi, Hi, Lo, LoLo. Input the expected values then move
mouse pointer to “UPDATE” and click. Escape the “SETUP” window to
complete.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Setup of Record / Print / Time : (Open up “PANEL” window is required)
ꢁ Move mouse pointer to “Option” then click. Move mouse pointer to
“Setup” and click this button.
ꢂ In the window “SETUP”, select the option button named “CLOCK” under
31
Download from Www.Somanuals.com. All Manuals Search And Download.
the title “MODE”. Under the “CLOCK” title.
A. Setup time of the meter manually :
a). Move mouse pointer to “TIME SET” then click. While the warning
message appears, click “OK”.
b). Drag mouse to highlight the values of YEAR / MONTH / DATE /
HOUR / MINUTE / SECOND under the red title “DATE” or “TIME”.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
c). Input the expected values and then click the right bottom button
“SETUP”.
d). While the “START/STOP REC/PRT with timing…….” appears, click
“Cancel” and then escape the “SETUP” mode.
B. Setup time of REC/PRT automatically
a). Drag mouse to highlight the values of HOUR \ MINUTE \ SECOND under
the title “START” then input the expected values.
b). Drag mouse to highlight the values of HOUR \ MINUTE \ SECOND under
the title “STOP” then input the expected values.
c). Drag mouse to highlight the values of HOUR \ MINUTE \ SECOND under
the title “INTERVAL” then input the expected values.
d). Move mouse pointer to “SETUP” located at right bottom then click this button.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
e). While the “START/STOP REC/PRT with timing…….” appears, click
“OK”.
f ). While the P / R signal appears (in the window of “PANEL”), move mouse
pointer to this signal and then click to set up the Start / Stop time of
record / print.
11. Setup the print mode of the meter :
ꢁ Move mouse pointer to “Option” then click. Move mouse pointer to
“Setup” and click this button.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ In the window “SETUP”select the option button named “PRINTMODE”under
the title “MODE”.
ꢁ
Under the “PRINT” title, select a print mode and then click that button.
Escape “SETUP” mode to complete.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
5-3 Meter Stand alone Operation :
1. How to clear “ Data Logger ”
(Press “ RECORD ” + “ POWER ON ”,
the LCD will be show “dEL”.
(After “ POWER ON ”, release “ RECORD
”, button.
2. How to do trigger record
(Press “ RECORD ” button 1 second,
the LCD ꢀ or
will be display.
(Release “ RECORD ” button the
LCD ꢀ or
symbol will be clear.
3. How to consecutive Record/Print (Ⅰ)
(Press and hold “ RECORD ” or “
PRINT ” button approximate 3
second, the ꢀ or
symbol will
be display.
(Release “ RECORD ” or “ PRINT ”
button, the LCD ꢀ or
symbol
will be disappear.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
4. How to set consecutive Record/Print (Ⅱ)
( Press “ SETUP ” button
approximate 3 second, the LCD
should show “ SET ” symbol.
123
(Repeat press
Button, choose
Print/Record/Print, Record function,
the LCD will show ꢀ/
/
ꢀ
(Press “ SETUP ” button, back to
general mode, the “ SET ” symbol
will be clear and shows ꢀ/
/
ꢀ by choice LCD.
5. How to stop consecutive Record/Print (Ⅰ)
(Press and hold “ RECORD ” or “
PRINT ” button for 3 seconds to
stop function.
(Stop consecutive Record/Print
function the LCD ꢀ or
clear
will be
.
6. How stop consecutive Record/Print (Ⅱ)
(If the “ START ” and “ STOP ”
function have been set, the printer
will be stopped when “STOP” time
is up.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
5-4 Download Datalogger (Graphic Recorder PC)
Move mouse pointer to “Option” then click. Move mouse pointer to “Memory”
and then click this button to read recorded data in memory.
*
As above, the total memory size is 128K, 126.8K remained.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Move mouse pointer to “Numbers of Sets” then click this button to show how many
sets have been recorded in the memory of Graphic Recorder (EEPROM).
2. Move mouse pointer to “Time of Sets” then click this button.
There will be a list that shows the recording time of each set.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Move mouse pointer to the list and choose a set then click. The number of
records for this set will be shown.
4. For more details of the chosen set, move mouse pointer to “Show Data”
and then click.
SAVE : To save data recorded in HD and to apply for other applications such as
EXCEL, WORD. For example, P.42
a). Move mouse pointer to “SAVE” then click this button.
b). There comes up a dialog box. Input the name of the file if willing to
save as.
c). Click “OK”
40
Download from Www.Somanuals.com. All Manuals Search And Download.
5-5 Data Conversion
1. Save data by RS-232 communication port in PC.
ꢁ Open Graphic Recorder software, check if Graphic Recorder connected and
PC is well. If not the “ NO COM ” signal will be displayed, please be sure
RS-232 cable is plugged and secured to COM1 or COM2. After a good
connection, the COM1 or COM2 symbol will be showed on the screen.
ꢂ Move mouse pointer to “File”, then click. Move mouse pointer to “ SAVE
AS ” then click this button. You can find the “ open file ” dialog box,
please change to new file name : *.xls from original file *.dat then press
enter. For example : test.xls
"
41
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢄ Move mouse pointer to “File”, then click. And move mouse pointer to “
START RECORDING ”, then click this button. The “RECORDING”
signal and No.s of PC record will display from 1 up to end.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
To end this record function, move mouse pointer to “File”, then click. Move
mouse pointer to “ STOP RECORDING ”, click the button. The “
RECORDING ” signal will disappear.
2. Apply for Excel : Open Microsoft EXCEL, go to “open file ”, from the searching function.
ꢂ
Find the EXCEL type. For example, test.xls. Select test.xls then click
“open” button.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ From the “ Files of type ”, click the pull down pointer, then choose “All
Files ”, select sample.dat then click “open” button.
ꢄ The “ Text Import Wizard ” then appears, click finish button, the selected
data will show in excel type.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
5-6 On-Line Operation with PC
1. Switch off all power related to your PC.
2. Connect the socket (female) of RS-232 cable to PC’s COM1 or COM2.
3. Switch on all power.
4. Connect the male socket of RS-232 cable to Graphic Recorder.
5. Run the Grapher software
Click “ Start ” from Start menu, move mouse pointer to “ Programs ”, then
move pointer to “Omega” (default), move mouse pointer to “GRAPHER”
then click.
6. Move mouse to available comport (COM1 , COM2) then click.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Main tableau
ꢁ Time Setup:Move mouse pointer to “ System Time Set ” then click to
input the time of PC to the Graphic Recorder.
When “ WAIT ” (in the center of the windows) disappeared, setup of
time is completed.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢂ RESET:Reset current maximum and minimum values. Move mouse
pointer to “RESET” then click this button to complete.
ꢄ Save data in HDD:
a). Move mouse pointer to “File” then click. And move mouse pointer to
“ SAVE AS ” then click this button. There shows a dialog box to
open file. Input a file name then press “ OK ”.
"
47
Download from Www.Somanuals.com. All Manuals Search And Download.
b). Move mouse pointer to “File” then click. And move mouse pointer to
“Start Recording”, then click this button. The “Recording” meanwhile
from 1 up to end also will show the Numbers of PC recording.
c). If willing to end this recording, please move mouse pointer to “File” then
click. And move mouse pointer to “Stop Recording”, then click this
button. The “Recording” signal will disappear.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
d). Move mouse point to “File” then click. And move mouse pointer to
“OPEN FILE”, then click this button. There comes a dialog box to open
file. Input the saved file name to read.
To show reading values in “ GRAPH ” type, move mouse pointer to
”Display” then click. And move mouse pointer to “GRAPH” then click
this button.
"
49
Download from Www.Somanuals.com. All Manuals Search And Download.
a). Print : to print graph.
b). Limit : Move mouse pointer to “ Limit ”, then click this button. There
comes a dialog box. Input the willing setting and then click “
OK ”. The graph page will show which records on each.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
! To show reading values in LIST type, move mouse pointer to “Display”
then click. And move mouse pointer to “List” and then click this button
to launch.
"
51
Download from Www.Somanuals.com. All Manuals Search And Download.
" PC SAMPLING:(Default : 2 seconds). Change the sampling time of
PC. Move mouse pointer to “Display” then click. And
move mouse pointer to “Sample Rate” then click this
button.
There shows a dialog box “ Input Sampling Time ”. Input the willing
seconds the click “ OK ” to complete this setting.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
# Operation of connecting with other meters :
A. Tes meters :
a). Move mouse pointer to “Option” then click. And move mouse pointer
to “Setup” then click this button.
b) In the window “SETUP”, move mouse pointer to “TES METER” which
is under the title “MODE” then click this option button.
c). Select an expected meter and then press “OK” to complete.
B. Other meters not in the list :
a). Move mouse pointer to “Option” then click. And move mouse pointer
to “Setup” then click this button.
b). Comply with the output voltage / current of which meters then refer
to P.27 (7).
c). Comply with the unit of which meters then refer to P.28 (8).
53
Download from Www.Somanuals.com. All Manuals Search And Download.
$ Process Transducer ( Od Mode )
a). Move mouse pointer to “ Option ” then click. Move mouse pointer to
“ Od Mode ” and then click this button. There shows an “ Input HiHi
Alarm ” dialog box. (as below)
b). In this dialog box, input the willing values and then press “ OK ” to
complete.