INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Heat-A-Ventlite®
93⁄4
"
(with Night Light)
MODEL: 9965
73⁄4
"
FOR BEST RESULTS
In a new construction site, install the housing (complete
with heater and ventilator) during rough-in construction of the
building. The light assembly and the grille should be installed
when the finished ceiling is in place.
14"
Installation in an existing, finished building requires an
accessible area (attic or crawl space) above the planned
location. See “INSTALLATION IN EXISTING
CONSTRUCTION.”
FIGURE 1
Do not install closer than 12 inches to a vertical surface.
Do not install over tub or shower enclosure.
UNIT DIMENSIONS
Refer to Figure 1 for housing's dimensions.
NOTE: If there will be a finished second floor above,
the Model 9965 housing requires a minimum of 2" x 8"
joist construction for mounting.
WIRING AND DUCTWORK
1. Run the required wiring during rough-in stage of
construction.
HANGER BARS
2. Total connected load: 1730 watts.
3. Plan to run 120vAC, 60 Hz wiring (with ground) on a
separate 20 Amp circuit from a power source, through
the provided wall switch, to the housing's junction box.
See wiring diagram.
FIGURE 2
JUNCTION
BOX
COVER
4. Use 4" round duct.
INSTALLATION IN
NEW CONSTRUCTION
PREPARATION
1. Install hanger bar brackets in slots in housing. (See Fig. 3)
Do not tighten completely to allow bars to be inserted.
2. Refer to Figure 2. Insert hanger bars into brackets.
3. Refer to Figure 3. Slide hanger bar brackets down to end
of slot closest to outside edge of housing. Tighten brackets
in this position.
4. Refer to Figure 4. Remove junction box cover by
ADJUSTMENT
SLOT
removing one screw.
5. Refer to Figure 4. Remove appropriate wiring knockout(s)
and install approved box connector(s).
KNOCKOUTS
FIGURE 3
FIGURE 4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION IN
EXISTING CONSTRUCTION
In an existing, finished building, installation of the Heat-
Vent-Light Combination requires an accessible area (attic or
crawl space) above the planned location. If the location that
has been chosen for installation has a finished floor above it,
be certain there is sufficient space available to install the
housing and make the necessary duct connection.
PLANNING
Review “INSTALLATION IN NEW CONSTRUCTION” and
follow all instructions that apply.
CAUTION: Check the area above the planned location
to make sure that:
(1) Ducting can be installed.
(2) Wiring can be run to the planned location.
(3) No wiring or other obstructions might interfere with
the installation.
INSTALLATION
1. The housing must be mounted between ceiling joists.
2. Refer to Figure 10. Mark ceiling for cutout. Cutout
dimensions: 141⁄8" long x 97⁄8" wide. Make cutout in ceiling.
3. Follow steps under “PREPARATION” page 1.
4. From above, lower housing into the cutout and secure
hanger brackets. Install duct collar, connect duct, and run
wiring through box connectors.
(LENS DETACHED
IN DRAWING FOR
ILLUSTRATIVE
PURPOSES)
LENS
FIGURE 9
5. From below, adjust housing so that it is flush with the
finished ceiling.
6. Form below, make wiring connections as shown in figure 6.
7. Replace junction box cover.
8. Insert heater, ventilator, light, and night light plugs into
proper receptacles.
9. install grille, reflector and lens.
141⁄8
"
97⁄8
"
WHITE
HEAT
VENT
FIGURE 8
FIGURE 10
Download from Www.Somanuals.com. All Manuals Search And Download.
One Year Limited Warranty
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period
of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Date of Installation
Builder or Installer
Model No. and Product Description
IF YOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest NuTone Independent Authorized Service Center:
Residents of the contiguous United States Dial Free 1-800-543-8687
Please be prepared to provide:
Product model number • Date and Proof of purchase • The nature of the difficulty
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.
Rev. 03/2001
Product specifications subject to change without notice.
Printed in U.S.A., Rev. 03/2001, Part No. 89356
Download from Www.Somanuals.com. All Manuals Search And Download.
EFFECTIVE
DATE
PRODUCT
GROUP
MODEL NUMBER
PARTS LIST
MAY
1999
9965
REVISED
HEATER
4
10
11
5
13a
9
3
12
7
6
14
15
8
9
2
13
16
17
18
24
19
1
VENT
HEAT
21
20
NIGHT
LIGHT
LIGHT
22
23
NOT A PARTS DEPT.
STOCK ITEM
REF.
NO.
ORIGINAL
PART NO.
*PART DESCRIPTION
REPLACEMENT
PART NO.
1
2
K3132
K9010
K3135
K3136
K3137
K3097
K3160
K3096
K3094
K3143
BEZEL/LENS ASSEMBLY
89340-000
89339-000
89375-000
35758-000
35759-000
66204-000
57976-000
56721-000
57117-000
30652-000
GRILLE
3
REFLECTOR
4
SOCKET-LARGE
5
SOCKET-SMALL W/CLIP
RECEPTACLE-BLACK
RECEPTACLE-BLUE WIRE
RECEPTACLE-WHITE
MOUNTING BRACKET (1) - 4 Required
DUCT ADAPTOR
6
7
8
9
10
(PLEASE SEE OTHER SIDE)
NOTE: Always order by
current part number.
Download from Www.Somanuals.com. All Manuals Search And Download.
REF.
NO.
ORIGINAL
PART NO.
*PART DESCRIPTION
REPLACEMENT
PART NO.
11
12
13
13a
14
15
16
17
18
19
20
21
22
23
24
*
K3010
K3117
K3122
82404
K3121
K3118
K3102
K3111
K3110
K3112
K3360
K3107
K3146
K3147
K3148
K9012
HANGER ROD ASSEMBLY (1) 2 Required
"B" UNIT ASSEMBLY-VENT
BLOWER WHEEL
85585-000
86693-000
82403-000
82404-000
89321-000
2908A-000
89306-000
66583-000
89315-000
23255-000
1179A-000
89312-000
85918-000
85920-000
85921-000
89323-000
PUSH NUT
MOTOR (VENT)
SCROWL (PLASTIC)
"B" UNIT ASSEMBLY (HEAT)
BLOWER WHEEL (HEAT)
MOTOR (HEAT)
MOTOR BRACKET
THERMAL PROTECTOR
HEATING ELEMENT
SWITCH ASSEMBLY COMPLETE - HARDWARE BAG ASSEMBLY
SWITCH PLATE
SWITCH DOUBLE - (2 Required)
GRILLE SCREW NOT SHOWN
NOTE: Always order by
current part number.
9965 I.I.
HEATER
JUNCTION BOX
HEATER
LIGHT
VENT
(WHITE)
BLK
BLU
RED
BLK
WHT WHT
WHT WHT
NIGHT
LIGHT
T
VENT
HEAT
LIGHT
NIGHT
LIGHT
SWITCH
BOX
NOTE:
WHEN THERMOSTAT
OR TIMER IS USED,
CONNECT AT
T
120vAC
LINE
Download from Www.Somanuals.com. All Manuals Search And Download.
|