Lennox's Glass Door/End Panel Packaged Set, Models 38ACR and
38ACR-BB, are designed to be installed on the CR-3835R/L Series
fireplaces. These kits come complete with all of the required hardware
necessary to complete the task.
F
E
Please read and understand these instructions carefully before begin-
ning installation and operation. Do not attempt to alter or modify the
constructionoftheseglassdoorassembliesasitcouldcauseamalfunc-
tion or possible fire hazard.
D
Figure 1
The Models 38ACR and 38ACR-BB have been tested and listed by Omni
Test Laboratories, Inc.
END PANEL INSTALLATION STEPS
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
GENERAL INFORMATION
Step 1. Remove the screen rod covers from the front and corner
openings. Remove two angle retainers and replace screws.
Note: Units are shipped without covers installed.
Before starting the installation of the glass doors and end panel, assure
the kit is complete and undamaged. Refer to Figure 1 and the inventory
list to identify all necessary parts.
Step 2. Refer to Figure 2and remove the top two outer screws and loosen
the bottom screws at least two (2) turns. Remove corner shipping post,
if installed.
INVENTORY LIST
CAUTION: REMOVE THE PLASTIC PROTECTIVE COATING FROM ALL
BRASS PIECES BEFORE INSTALLATION.
A. (1) Top Channel (door)
B. (1) Bottom Channel (door)
C. (1) Top Channel (panel)
D. (1) Bottom Channel (panel)
E.(1) Corner Post
F. (1) Glass End Panel
G. Door Panel Assembly LH
H. Door Panel Assembly RH
J. (2) Baffles
K. Hardware Kit (Including
Handles) Installation Instructions
US
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Download from Www.Somanuals.com. All Manuals Search And Download.
*Note: Upper door hinge pins can also be
loosened for adjustment purposes; however, it
is easier to loosen lower pins.
Upper Door
Guide Track
CLEANING
Hinge Pin
Roller Pin
NEVERCLEANTHEGLASSWHENTHEDOORS
ARE HOT. DO NOT USE AMMONIA OR ANY
AMMONIA BASED GLASS OR HOUSEHOLD
CLEANERTOCLEANTHEGLASSORTHEDOOR
FRAME. ANAMMONIABASEDCLEANERWILL
DAMAGE THE FINISH.
GENERAL OPERATING PRECAUTIONS
AND INSTRUCTIONS
CAUTION: THESE GLASS DOORS ARE
LISTED ONLY FOR USE WITH THE SUPE-
RIOR FIREPLACE OR APPLIANCE MODELS
SHOWN. USE ON ANY OTHER FIREPLACE
OR APPLIANCE MAY CONSTITUTE A PO-
TENTIAL FIRE HAZARD.
Remove dirt and grime from the doors using a
clean dampened towel followed by wiping with
a dry towel. To remove stubborn stains from
thedoors,useamildsoapsolutionandtowelto
gentlyscrubawaystain.Takecarenottoscratch
theglasssurface.Donotuseabrasivecleaners.
Figure 9
Step 5. Lift and swing the lower corner of the
door over the hole in the bottom door channel
and engage the shorter hinge pin into this hole
(Figures 10 and 11 ).
• Avoid building extremely large fires as the
tempered glass could become damaged.
IMPORTANT
• Use fireplace tools carefully to avoid striking
These glass doors utilize tempered glass
which is designed for use with high tempera-
tures but can unexpectedly shatter. DO NOT
SIT CLOSE TO THE GLASS.
the glass.
Bottom
Door
Channel
• Keep wire mesh screens closed during fire-
place use.
Temperedglasswillbreakintosmallparticlesif
it should shatter unexpectedly. If the glass
breaks, particles of extremely hot glass could
be discharged into the surrounding environ-
ment, thereby creating a risk of personal injury
or fire. Observation of the above operating
precautions and instructions will reduce the
risk of personal injury or fire.
• The fireplace flue damper must remain open
until fire is completely out.
• Assure wood and embers are well within the
confinesofthegrateareaandwellawayfrom
the glass doors.
Pivot
Point
• Keep glass doors closed at night when retir-
ingtominimizethelossofheatedroomairup
the vent.
Figure 10
Extremetemperaturechangescancausebreak-
age — do not build a hot fire and close the
doors if the doors are cold.
CAUTION: THE CORNER FIREPLACE OR AP-
PLIANCE SHOULD ONLY BE OPERATED WITH
THE BI-FOLD GLASS DOORS FULLY OPEN OR
FULLY CLOSED (FIGURE 12 ).
If the tempered glass pane becomes scratched
or chipped, it creates a weakness in the glass
whichcancausetheglasstobreakwhenheated.
Replace the pane of glass by contacting your
nearest LHP Distributor. For the name of your
nearest distributor contact:
End Panel
LENNOX HEARTH PRODUCTS
1110 West Taft Avenue
Orange, CA 92865
Lower Hinge Pin
Figure 11
Step 6. Repeat this procedure for the opposite
door assembly.
WARNING: DO NOT BURN TRASH,
CONSTRUCTIONSCRAPS, RAILROAD
TIES, OR OTHER HIGHLY-FLAM-
MABLE MATERIAL IN THE FIRE-
PLACE. INTENSE HEAT CAN CAUSE
THEGLASSTOLOSESTRENGTHAND
RESILIENCEWHICHWILLRESULTIN
GLASS BREAKAGE.
ADJUSTMENT FOR DOOR ALIGNMENT
Fully Open or
Fully Closed
The doors are properly adjusted when the top
door trim is in a straight, level line and the gap
between the doors is even at the top and
bottom. If adjustments are required, grasp the
door handle and loosen the lower door hinge
pin using a 3/8" open end wrench*. Slide the
door panel on the hinge pin until the gap
between the upper door trim and upper frame
is even. Retighten the lower door hinge pin*.
Repeat this procedure for the opposite door if
needed.
Figure 12
CAUTION: GLASS AND METAL FRAMES GET
HOT—ALWAYSUSEHANDLESTOOPENAND
CLOSE THE DOORS.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
3
Download from Www.Somanuals.com. All Manuals Search And Download.
The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 1999 by LENNOX HEARTH PRODUCTS
P/N 904665 REV. C 03/2008
1110 West Taft Avenue • Orange, CA 92865
Download from Www.Somanuals.com. All Manuals Search And Download.
|