INSTALLATION AND OPERATION MANUAL
EPA Certified
Wood-Burning
Fireplace Inserts
Save These Instructions
For Future Reference
Performer™ C210
and SWI210
P/N 775212M, Rev. C, 09/2011
Performer™ CA210
Wood Fireplace Inserts
Performer™ Models C210,
CA210 and SWI210
A French manual is available upon request. Order P/N 775212CF.
Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de
la pièce 775212CF.
This appliance must be properly installed and operated in order to prevent the
possibilityofahousefire. Pleasereadthisentireinstallationandoperation
manual before installing and using your wood fireplace insert. Failure
tofollowtheseinstructionscouldresultinpropertydamage, bodily
Portland
injuryorevendeath.Contactyourlocalbuildingorfireofficials
US
to obtain a permit and information on any installation re-
quirementsandinspectionrequirementsinyourarea.
ReportNo.050-S-03b-2
WARNINGS
• Hot! Do not touch! The glass and surfaces of this appliance will
be hot during operation and will retain heat for a while after
shutting off the appliance. Severe burns may result.
• Carefully supervise children in the same room as appliance.
Download from Www.Somanuals.com. All Manuals Search And Download.
13. Inspect your chimney at least once a month during the burn-
ing season to check for soot and creosote accumulations.
Any accumulations over 1/8” thick should be removed by a
professionalchimneysweep.Donotattempttoburnoutheavy
creosoteaccumulationswithahotfire. Iflargeaccumulations
are occurring, review your burning procedures.
14. If a creosote fire should develop, the fire department should
be called immediately and then attempts should be made to
control the fire until assistance arrives. If a “runaway” fire
should develop causing over-heating of the insert, the door
and draft regulators should be closed immediately. The fire
should die down once deprived of oxygen. After a severe
chimneyfire,thecompletechimneysystemshouldbechecked
before further use.
15. Do Not Use Grate Or Elevate Fire - Build Wood Fire Directly
On Hearth (firebrick). Do not use andirons or other methods
of supporting the fuel.
16. Please read this entire manual before you install and use your
new room heater. Failure to follow instructions may result in
property damage, bodily injury, or even death.
17. Check all local building and safety codes before installation.
The installation instructions and appropriate code require-
ments must be followed exactly and without compromise.
In the absence of local codes the following standards and
codes must be followed.
18. In the U.S.A, install in accordance with the National Fire
Protection Association’s Code, NFPA 211, Standards for
Chimneys, Fireplaces, Vents and Solid-Fuel-Burning Appli-
ances, or similar regulations, may apply to the installation of
a Solid-Fuel-Burning appliance in your area. In Canada, the
guidelineisestablishedbytheCSAStandard,CAN/CSA-B365-
M93,InstallationCodeforSolid-Fuel-BurningAppliancesand
Equipment.
19. Do not connect to any air distribution duct or system.
20. WARNING: BURNING IMPROPER FUEL (I.E. CHARCOAL)
CAN RESULT IN CARBON MONOXIDE POISONING, WHICH
MAY LEAD TO DEATH!
21. Carbon Monoxide Poisoning – early signs of carbon monox-
ide poisoning resemble the flu with headaches, dizziness, or
nausea. If you have these signs, get fresh air at once! Have
the heater inspected by a qualified service technician. Some
people are more affected by carbon monoxide than others.
These include pregnant women, people with heart or lung
disease or anemia, those under the influence of alcohol, and
those at high altitudes.
IMPORTANT SAFETY AND WARNIING
INFORMATION
READ THIS MANUAL IN ITS ENTIRETY AND UNDER-
STAND THESE RULES TO FOLLOW FOR SAFETY.
1. When this room heater is not properly installed, a house fire
may result. To reduce the risk of fire, follow the installation
instructions. Contact local building or fire officials about
restrictions and installation inspection requirements in your
area.
2. Wear gloves during installation to avoid injury from sharp
edges on the insert and/or its parts.
3. This unit is designed and engineered to burn only dry, well-
seasoned wood. Burning wet wood will greatly reduce your
inserts efficiency, produce excessive amounts of smoke and
can cause dangerous chimney fires due to creosote build-
up.
4. Before opening the door, the draft control must be fully open
to avoid possible combustion flash (ignition of hot volatile
gases as the door is opened).
5. Never use gasoline, gasoline-type lantern fuel, kerosene,
charcoal lighter fluid, or similar liquids to start or ’freshenup’
a fire in this heater. Keep all such liquids well away from the
heater while it is in use.
6. While burning, fuel utilizes oxygen from the air in the room.
Be sure to allow an adequate amount of fresh air into the
room where the insert is burning.
7. The outside surface of the insert will be hot while burning
properly and can set items like clothing and curtains on fire.
Keep furnishings and other combustible materials away from
the insert. Using the heat from the insert to dry wet clothing
can be hazardous if clothes are placed too near the surface
of the insert.
8. Do not allow children to play near the insert without close
supervision. Do not touch the insert while it is burning. Use
extremecautionwhiletheunitisinuse. Surfacetemperatures
become dangerously hot and can cause serious burns.
9. Do not allow anyone to operate the insert who is not familiar
with the operating instructions.
10. Attemptstoachieveheatoutputratesthatexceedinsertdesign
specifications can result in permanent damage to the insert.
Never leave your insert unattended on high burn rates. This
maycauseoverfiring. Overfiringtheinsertmaycauseahouse
fire. If the insert glows, you are overfiring.
11. Keep a water hose or hand-operated fire extinguisher close
for safety.
12. Smoke Detectors - Since there are always several potential
sources of fire in any home, we recommend installing smoke
detectors. If possible, install the smoke detector in a hallway
adjacent to the room (to reduce the possibility of occasional
false activation from the heat produced by the insert). If your
local code requires a smoke detector be installed within the
same room, you must follow the requirements of your local
code. Check with your local building department for require-
ments in your area.
22. Failure to use manufacturer provided parts, variations in
techniques and construction materials or practices other than
those described in this manual may create a fire hazard and
void the limited warranty.
23. Donotmakeanymake-shiftcompromisesduringinstallation.
Any modification or alteration may result in damage to the
appliance or dwelling and will void the warranty, certification
and listings of this unit.
24. These appliances are designed as supplemental heaters.
Therefore, it is advisable to have an alternate heat source
when installed in a dwelling.
25. Do Not Overfire – If Heater or Chimney Connector Glows,
You Are Overfiring.
26. DONOTCONNECTTHISUNITTOACHIMNEYFLUESERVING
ANOTHER APPLIANCE.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
read greater than .04’ W.C. (inches water column) and less than .08”
W.C. As per NFPA-211 standard (see paragraph below), the installer
must take into account all variables within the installation and install the
appliance in such a manner that satisfies the draft requirements of the
appliance. See Chimney Guidelines below to assist you in selecting the
proper venting system for your installation.
TESTING INFORMATION
Thismanualdescribestheinstallationandoperationofthesenon-catalytic
wood heaters. These heaters meet the U.S. Environmental Protection
Agency’s emissions limits for wood heaters sold on or after July 1, 1990.
This heater has been developed, tested and constructed in accordance
with the requirements of UL 1482, ULC S628 and HUD standards and
is listed by OMNI Test Laboratories, Portland, OR. It has been approved
for residential and alcove installations.
American National Standards Institute ANSI/NFPA 211, Standard for
Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances
- See Draft Section: A chimney or vent shall be so designed and con-
structed to develop a flow sufficient to completely remove all flue and
vent gases to the outside atmosphere. The venting system shall satisfy
the draft requirements of the connected appliance in accordance with the
manufacturer’s instructions.
DRAFT REqUIREMENTS
Your wood fireplace insert is dependent upon a properly functioning
chimney for optimum performance. It is a high efficiency appliance that
losesmuchlessheatupthechimneythanolderappliancesandfireplaces.
For this reason it is important to match the fireplace insert to the chimney.
The chimney has two functions:
Chimney Guidelines:
• This appliance requires approximately 12 feet minimum of “effective
draw” provided by the venting system. As a rule of thumb, every 90
degree total direction change in the venting will result in a loss of
approximately 5 feet of “effective draw.” Example: If two 45 degree
offsets are used, subtract 5 feet from the actual vertical vent height
to determine your “effective draw.” In this case if you had 14 feet of
vertical vent, the effective draw would only be approximately 9 feet
(14 ft. - 5 ft. = 9 ft.), therefore it may be necessary to add additional
height to the venting system.
1. It draws combustion air into the appliance (without air, no fuel will
burn) and
2. It exhausts combustion by-products. Your new appliance is what is
known as a “natural draft” appliance.
The appliance depends solely on the natural draft of the chimney system
to draw combustion air into the unit. Draft is the force that moves air from
the appliance up into the chimney. The amount of draft in your chimney
dependsonthelengthofthechimney,localgeography,nearbyobstructions
and other factors. Too much draft may cause excessive temperatures in
the appliance (overfiring). Slow or inadequate draft equals poor combus-
tion and possible smoking problems. The following are some conditions
that may contribute to poor chimney draft:
• Inwellinsulatedandweathertighthomes,itmaybedifficulttoestablish
a good draft up your chimney. The poor draft is caused by a shortage
of air in the house (see Negative Pressure Warning on Page 5).
Chimney Height Requirements
The chimney must extend 3’ (.92m) above the level of roof penetration
and a minimum of 2’ (.61m) higher than any roof surface within 10’
(3m) (see below). Check with your local building officials for additional
requirements for your area.
1. A chimney too large for your appliance.
2. A chimney with not enough height to produce adequate draft.
3. A chimney with excessive height (this may allow exhaust to cool too
much before exiting, which will stall the rate the exhaust exits).
4. Offsets in the venting system are too restrictive (see Chimney Guide-
lines).
Less than
10' (3 m)
Inadequate draft will cause the appliance to leak smoke into the room
through the fireplace insert and the chimney connector joints.
2’ (610 mm) Min.
Excessive draft may cause an uncontrollable burn or a glowing red
fireplace insert or chimney part.
3' (914 mm)
3'
Min.
10'
(3 m)
(914 mm)
Min.
Overfiring Damage - If the heater or chimney connector glows, you are
overfiring. Other symptoms may include: Cracking, warping or burning
out of components, plated accessories may turn color, stove glass may
develop a haze, which will not come off with cleaning.
Overfiring of a stove or fireplace insert is a condition where excessive
temperatures are reached, beyond the design capabilities of the appli-
ance. The damage that occurs from overfiring is not covered under the
manufacturer’s limited warranty.
Figure 1 - Chimney Height Requirements
To pass inspection in nearly any jurisdiction, the chimney must meet both
safety and exhaust flow requirements. The (3’ by) 2’ by 10’ rule applies
to both masonry and factory-built chimneys.
Also see Troubleshooting on Page 17.
* Ref. USA - National Standard, NFPA 211-latest edition and Canada
National Standard CSA B365-01-latest edition. Vents installed with a
listed cap shall terminate in accordance with the terms of the cap’s
listings.
SELECTING THE PROPER VENTING SYSTEM
The appliance is merely one component of a larger system. The other
equally important component is the venting system. This is necessary for
achieving the required flow of combustion air to the fire chamber and for
safely removing unwanted combustion by-products from the appliance.
If the venting system’s design does not promote these ends, the system
maynotfunctionproperly.Poorlyfunctioningventingsystemsmaycreate
performance problems as well as be a safety hazard. A draft test should
4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Dry, seasoned wood is that which has been cut, split and allowed to dry
under a covered area where air is free to flow and circulate under and
around the wood (not under a tarp or plastic). Make sure wood is not
stacked directly on the ground, it may absorb moisture from the ground.
It should be allowed to dry in these conditions for a minimum of six
months, preferably one year or more. IT MUST BE UNDERSTOOD THAT
WOOD CANNOT BE LEFT IN ANY KIND OF WET OR DAMP AREA OR IT
WILL NEVER BECOME COMPLETELY SEASONED. Your fireplace insert
will not operate at the level that it is meant to unless you use seasoned,
dry wood. Do not burn driftwood or wood that has been in salt water,
doingsowillvoidyourwarranty. Donotburntreatedwood, coal, garbage,
cardboard, solvents, or colored paper. Burning treated wood, garbage,
solvents, or colored paper may result in the release of toxic fumes. This
type of burning will also void your warranty.
NEGATIVE PRESSURE WARNING
This appliance is not designed to be operated in a negative pressure.
In very airtight homes with large kitchen exhaust fans, furnace cold air
returns, fresh air exchange systems and any other air system in close
proximity to the heating appliance may create a negative pressure in the
same room as the heating appliance. This can create dangerous back
drafting of the fireplace insert and chimney joints, drawing combustion
by-products into the home. Be sure your home has adequate makeup air
to eliminate negative pressures caused by the above-mentioned sources.
Lennox Hearth Products accepts no liability for damages resulting from
negative pressures described above.
Ventilation Requirements - Provide adequate air for combustion. The
fresh air requirements of this appliance must be met within the space
where it will be installed. Ventilation is essential when using a Solid-Fuel-
Burning heater. In well insulated and weather tight homes, it may be
difficult to establish a good draft up the chimney (caused by a shortage
of air in the home). The lack of air is caused by many common household
appliances which exhaust air from the home (such as a furnace, heat
pump, air conditioner, clothes dryer, exhaust fans, fireplaces, and other
fuel burning appliances). Also, the combustion process of this heater
uses oxygen from inside the dwelling. If the available fresh air delivery
in the dwelling is insufficient to support the demands of these appliances,
problems can result (i.e. excessive negative pressure can develop in the
dwelling which will affect the rate at which this appliance can draft thus
resulting in performance problems. To correct this problem it may help
to open a window (preferably on the windward side of the house).
PAINT CURING
If your fireplace insert has plated accessories, be sure to clean it
with a household type glass cleaner and a very soft cloth to remove
any fingerprints and residues prior to the first fire and before any fire
if the gold has been handled or soiled. Do not close the door tightly
during the “Burn-In Period.” Also, open the door frequently (every
5-10 minutes) to keep the gasket from adhering to the curing paint.
Ventilate the house well during these first firings as the paint gives off
carbon dioxide and unpleasant odors. It is recommended that persons
sensitive toan imbalance in theindoorair quality avoid the fireplace insert
during the curing process.
Your new appliance is painted with a high temperature paint that cures
during the first few firings. We recommend that you put your fireplace
insert through a regimen of three burns. The first two should last for 20
minutes each at 250 degrees (the fireplace insert should be allowed to
cool completely between each burn). The third should be a burn of at least
450 degrees F. for 45-60 minutes. The paint will become soft, gummy
and emit non-toxic smoke during these burns. After the fireplace insert
cools down for the third time, the paint will harden. DO NOT BUILD A
LARGE ROARING FIRE UNTIL THIS CURING EFFECT IS COMPLETE OR
YOU MAY DAMAGE THE FINISH OF YOUR STOVE OR INSERT. Spray
can touch-ups should be done only with a high temperature stove paint
(cat. no. H8159), available from all Lennox Hearth Products dealers.
CREOSOTE, FORMATION AND NEED FOR REMOVAL
When wood is burned slowly, it produces tar and other organic vapors,
which combine with expelled moisture to form creosote. The creosote
vapors condense in the relatively cool chimney flue of a slow-burning
fire. As a result, creosote residue accumulates on the flue lining. When
ignited, this creosote makes an extremely hot fire. The chimney and
chimney connector should be inspected at least once monthly during
the heating season to determine if a creosote buildup has occurred. If
creosote has accumulated, it should be removed to reduce the risk of
a chimney fire.
BURN-IN PERIOD
Please be patient with the heat output of your fireplace insert for the first
few weeks. The steel will go through a curing process that eliminates
moisture, which is deep in the steel and firebrick. This moisture will
reduce initial heat output of your fireplace insert and may make it dif-
ficult to start. After you have broken in the paint on the fireplace insert
it will be necessary to build hot fires to thoroughly remove the moisture
from the appliance. Running the fireplace insert with the draft fully open
for 1 to 1-1/2 hours after starting and adding generous amounts of fuel
during the first week or two should complete the curing process. We
recommend the use of a thermometer attached to the fireplace insert
top or chimney. Temperatures on the connector pipe should run in the
250-600 degree range. (DO NOT OVERFIRE THE STOVE OR INSERT
DURING THIS PROCESS. IF THE STOVE OR CHIMNEY BECOMES
RED, REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR
INSERT IMMEDIATELY).
DISPOSAL OF ASHES
Ashes should be scooped out of a cool fireplace insert with a small metal
shovel. Ashes should be placed in a metal container with a tight fitting
lid and moved outdoors immediately. Other waste shall not be placed
in this container. The closed container of ashes should be placed on a
non-combustible floor or on the ground, well away from all combustible
materials, pending final disposal. If the ashes are disposed of by burial in
soil or otherwise locally dispersed, they should be retained in the closed
container until all the cinders have thoroughly cooled. Ashes can ignite
up to 72 hours after removal from the fireplace insert.
FUEL
This unit is designed and engineered to burn, dry, well-seasoned wood
only.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Firebox Brick Layout Viewed From the Front
BRICK INSTALLATION
24
E
25
H
26
E
Figure 2
CAUTION: Wear gloves during brick installation in case of sharp
edges behind the fireplace insert.
1
F
2
F
3
G
4
F
5
F
10*
F
6*
F
Note: Installation of the baffle boards and baffle blankets are easier when
you can still access the flue outlet, (before connecting the flue vent). Be
sure the baffle blankets are placed flat on the baffle boards so as not
to block exhaust flow to the flue. Use a ruler or a piece of kindling to
reach over the baffle blanket to be sure it is completely flat on top of the
baffle boards.
11
F
7
F
8
F
12
F
14
F
15
17
F
18
F
16
G
13
S
F
9
S
Measure bricks before installing, as per list of dimensions on next page,
to be sure the correct bricks are installed in the correct location.
1. Install bricks #1-26 in the numbered sequence shown in Figure 2.
Important: The secondary burn tubes at the top of the firebox are
supported by a metal bracket. Move this bracket so it is centered
left and right on the tubes. Also make sure the small supporting
brackets on the front and rear tubes are centered and hanging from
the steel rods at the front and rear of the fireplace insert.
2. Next, you will install the baffle boards. All 4 baffle boards included are
the same size which is 15” x 4-3/4”. You will start by installing the
boards in the center part of the unit on top of the secondary tubes to
eachsideofthebafflesupportwiththe15”sideofthebaffleboardgoing
from the front to back of the unit. Once you have the first two boards
installed slide the board to the left side of the baffle support all the way
to the left and rear of the unit. You will slide the board to the right side
of the secondary support to the right and rear of the unit. Next you will
install the two remaining boards where you originally installed the first
two boards on each side of the baffle support and pushed against the
rear of the unit. The stainless steel support hanger should be centered
left to right between the sets of baffle boards and placed as shown in
Figure 4.
23
B
19
B
22
B
21
K
20
B
* Bricks 6 and 10 fit up against the back of the firebox.
Front View - See the following for brick sizes
*Fits against the back of the firebox.
Note: These bricks may be slightly smaller to adjust for steel and fire-
brick tolerances beyond our control. Be sure to measure and mark
bricks with their numbers when removing.
15”
Baffle
Insulation
Parts
1” Thickness
Two Baffle Blankets Per Unit
3. Also included with the unit are two 15” x 10” x 1” thick baffle blan-
kets. Install each blanket above the baffle board to each side of the
secondary support with the 15” side of the blanket from front to rear
of the unit. Make sure that the baffle blankets are to the full rear of
the unit.
10”
4. Also included with the unit are two 15” x 10” x 1” thick baffle blan-
kets. Install each blanket above the baffle board to each side of the
secondary support with the 15” side of the blanket from front to rear
of the unit. Make sure that the baffle blankets are to the full rear of
the unit.
15”
1/2” Thickness
4-3/4”
Four Boards Per Unit
CAUTION: Make sure the baffle blankets are down flat on the
baffleboards,pulledtogetherinthecentersothatnogapsexists
between them and do not protrude beyond baffle boards. It is
critical that baffle boards and baffle blankets are fully against
the rear of the unit.
Figure 3
Side Cut-A-Way
View of Firebox
Baffle Blankets
WARNING: IF THE BRICKS ARE NOT INSTALLED EXACTLY AS
SHOWN BELOW, THEY COULD FALL OUT OF PLACE DURING
REFUELING OR BURNING OF THE FIREPLACE INSERT CAUSING
SERIOUS INJURY!
Baffle
Board
Brick Sizes (see Figures on this page)
Firebox
Brick
E = 3 x 9”
F = 4-1/2 x 9”
G = 1-1/2 x 9”
H = 1-1/2 x 3”
K = 1-1/2 x 5-1/2”
S = 2-1/8”
Figure 4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Maximum Mantel Depth = 9” (229mm)
COMBUSTIBLE MANTEL
REqUIRED CLEARANCES
WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE
HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC-
TION IS NOT LESS THAN SHOWN ON THIS PAGE.
Top Facing / Trim
A
B
Model
*A
*B
*C
*D
E(1)
C/A210
SWI210
USA-24”
CAN-
813mm
USA -18”
CAN-
660mm
18”
15”
USA-8"
CAN-
200mm
450mm 381mm
D
C/A210 & SWI210
w/mantel and/or
side shields u
USA-16”
CAN-
813mm
USA -10”
CAN-
660mm
18”
USA-8”
USA-8"
CAN-
200mm
450mm 381mm
Insert
C
Hearth Protection
Model
F (1)
G
H
J(2)
M
E (Canada)
E (USA)
C/A210
SWI210
18”
450mm
12-1/4”
311mm
19”
483mm
4-1/2”
42-1/8”
Figure 5
114mm 1070mm
C/A210 & SWI210
w/mantel and/or
side shields u
18”
12-1/4”
311mm
19”
4-1/2”
114mm
34-1/8”
867mm
Mantel
Trim
450mm
483mm
*
Reduced clearances may be available for A, B, C and D dimensions per
NFPA 211 - latest edition, Standard for Chimneys, Fireplaces, Vents and
Solid Fuel-Burning Appliances (in Canada CSA B365 - latest edition). See
section on “Reduction of Appliance Clearance with Specified Forms of
Protection.”
**
** Side view of optional mantel deflector shown.
(1)Hearth extension reductions: 2” (51 mm) reduction for 2” (51 mm) raised
hearth. (USA) 16” minimum hearth extension on all stoves and inserts
as measured from the door opening of the unit. (Canada) 18”(450 mm)
minimum hearth extension on all stoves and inserts as measured from the
door opening of the unit. Minimum distance of floor protection to the side
= 8” (200 mm). This is measured from the sides of the door opening in the
USA and from the sides of the insert in Canada.
9”
229mm
G
M
F
J
6” Ø
Flue Collar
(2) J = Maximum lintel depth without flue offset or smoke deflector.
H
Notes:
• Facing material that projects more than 3/4” (19 mm) from the wall
is considered a mantel or side wall.
Hearth Protection
Figure 6
C/A210
SWI210
ZC Fireplace
UL 127
Masonry Fireplace
UBC Chapter 37
Top View
Depth Min.
Height Min.
Width Min.
12-1/2” (318mm)
21” (533mm)
12-1/2” (318mm)
19-1/4” (489mm)
26” (660mm)
36” (914mm)
4-1/2” (114mm)
4-1/2” (114mm)
Lintel Max. Depth
u
Without use of adjustable offset box or smoke deflector
u
Table 1 - Fireplace Sizing
23”
584mm
25-1/2”
648mm
Figure 7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the r formula:
Minimum
HEARTH PROTECTION
r-value (per Inch)
of listed material
r-value (per inch)
of alternate material
Specified min.
thickness
of listed
The hearth and/or floor protection must be a thermally rated non-com-
bustible hearth/floor protector meeting or exceeding a thermal rating of
k=.84 or equivalent with a listed thickness of 3/8" (9.5mm) minimum in
USA (3/4" - 19mm minimum in Canada). The covering must extend 18”
(450mm) in front of the heater and 8” (200mm) to either side (measured
from door opening in the USA and measured from the side of the unit
in Canada).
thickness of
alternate
material
=
x
material
rL
rM
TM (inches)
=
=
x
x
x
TL
TM (inches)
*1.19
*2.86
.375"
.375"
Using Alternate Material As Floor / Hearth Protection
.312 (inches)=
.416
The hearth extension or alternate material used as a floor/hearth protec-
tor must be constructed of a durable noncombustible material having
an equal or better thermal conductivity value (lower k value) of k =.84
BTU/IN FT2 HR °F or a thermal resistance that equals or exceeds r = 1.19
HR °F FT2 IN/BTU with a minimum thickness of 3/8” in USA or 3/4” in
Canada. With these values, determine the minimum thickness of the
alternate material required using the formula(s) and shown in Table 2
for USA and Table 3 for Canada.
Answer - The minimum required thickness of the Micore 160 is .156"
therefore round up to near est standard thickness available which is
3/8” (.375”)
Listed Material
k (per inch) r (per inch)
Listed Min. Thickness
Listed Material
.84
1.19
rL
3/8" (.375")
KL
TL
Note: Any noncombustible material having a minimum thickness of
3/8”(9.5 mm) for USA or 3/4” (19mm) in Canada whose k value is less
than .84 or whose r value is more than 1.19 is acceptable. If the alternate
material used has a higher k value or lower r value will require a greater
thickness of the material used. In some cases, if the k value is less or
the r value higher, a thinner material may be used.
** Approved Alternate Materials for Floor/Hearth Protection
Alternative Materials
Thermal Values
Minimum Thickness
(rounded to nearest 1/8 inch)
k (per inch) r (per inch)
Min. Thickness
KM
rM
TM
Kaowool M Board
.47
.35
2.13
2.86
.42" (1/2")
.31" (3/8")
Methods of determining floor protection equivalents:
To determine the thickness required for the alternate material when
either the "k" value or "r" value is known, use either the k formula or r
formula.
Micore 160™
U.S. Gypsum
Micore 300™
U.S. Gypsum
.46
2.17
.52
.41" (1/2")
Example: If Micore 160 Mineral Fiber Board is to be used for the floor
protection, how thick must this material be?
Durock™ Cement Board
U.S. Gypsum
1.92
1.71" (1-3/4")
Hardibacker™
1.95
2.30
2.82
.51
.43
.35
1.74" (1-3/4")
2.05" (2-1/8")
2.52" (2-5/8")
kM = k value per inch of alternate material
rM = r value per inch of alternate material
Hardibacker 500™
Cultured Stone Hearth-
stone™
TM = minimum thickness required for alternate material
TS = standard thickness of the alternate material
Wonderboard
3.23
.61
.31
2.88" (3")
.54" (5/8")
kL = k value per inch of listed material
rL = r value per inch of listed material
TL = minimum thickness of listed material
Super Firetemp M
Johns-Manville
1.64
Super Firetemp L
Johns-Manville
.54
1.85
.48" (1/2")
Note: An asterisk "*" indicates, it is a value taken from Tables 2 and 3.
Face brick
9.00
5.00
5.00
12.5
~11
.111
.20
8.04" (8-1/8")
4.46” (4-1/2")
4.46” (4-1/2")
11.16" (11-1/4")
9.82" (9-7/8")
Using the k formula:
Common brick
Cement mortar
Ceramic tile
Marble
FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS
.20
.08
Using the k formula:
~.09
Minimum
k-value (per Inch) of
alternate material (kM) x
k-value (per inch)
Specified min.
thickness
Table 2 - USA REQUIREMENTS
thickness of
alternate
=
of listed
material (TM)
of listed material (kL)
material (TL)
** If the hearth extension material(s) that is intended to be used is NOT listed
on Table 1, the material can still be used if the material(s) is noncombustible.
However,themanufacturerofthematerialmustprovideeitherthelistedk-value
per inch or r-value per inch with listed thickness so that the minimum thickness
required for the hearth can be calculated (per instructions here or as specified
in the NFI Certification Manuals).
TM (inches)
=
=
kM
x
x
x
TL
*.84
TM (inches)
*.35
*.84
.375"
.375"
Note: Also see NFI (National Fireplace Institute) Certification Manuals show-
ing other acceptable calculation methods and acceptable alternate materials
which can be used.
.156 (inches)=
.417
Answer -TheminimumrequiredthicknessoftheMicore160is.156"therefore
round up to nearest standard thickness available which is 3/8” (.375”)
SEE TABLE 3 ON FOLLOWING PAGE FOR CANADA REQUIRE-
MENTS
8
Download from Www.Somanuals.com. All Manuals Search And Download.
FOLLOWING EXAMPLES ARE CALCULATED FOR CANADA REQUIR-
MENTS
CHIMNEY REqUIREMENTS
Using the k formula:
This appliance is approved for use in a masonry fireplace built to UBC
Chapter 37 or equivalent with a minimum 26” (660 mm) opening at the
front of the fireplace.
Minimum
k-value (per Inch) of
alternate material (kM) x
k-value (per inch)
Specified min.
thickness
thickness of
alternate
=
of listed
Theseheatersaredesignedtobeinstalledintoanexistingmasonryfireplace
(built to UBC 37 or ULC S628 standards) or factory-built, solid-fuel and
wood-burning fireplaces (listed to UL 127 or ULC S610) only.
material (TM)
of listed material (kL)
material (TL)
TM (inches)
=
=
kM
x
x
x
TL
*.84
Do not remove brick or mortar from masonry fireplace to accommodate
insert. Approved with or without positive flue connection. Approved
with minimum 6” (152 mm) diameter stainless steel listed reline system.
Country Collection inserts are tested to UL 1482 / ULC S628 and listed
by OMNI-Test Laboratories, Inc.; Portland, OR.
TM (inches)
*.35
*.84
.75"
.75"
.312 (inches)=
.417
Answer -TheminimumrequiredthicknessoftheMicore160is.312"therefore
round up to nearest standard thickness available which is 3/8” (.375”)
IMPORTANT NOTE: See Draft Requirements and Selecting a Proper
Venting System on Page 4 to assist you in choosing the proper venting
system for your installation.
Using the r formula:
Remove and clean behind unit frequently, as creosote build-up may
occur rapidly.
Minimum
thickness of
alternate
material
r-value (per Inch)
of listed material
r-value (per inch)
of alternate material
Specified min.
thickness
of listed
=
x
material
INSTALLATION PROCEDURES - MASONRY CHIMNEY
rL
rM
TM (inches)
=
=
x
x
x
TL
Note: Although not required, a full-length stainless steel liner is recom-
mended for optimum safety and performance. See your Lennox Hearth
Products dealer for details.
TM (inches)
*1.19
*2.86
.75"
.75"
.312 (inches)=
.416
Answer -TheminimumrequiredthicknessoftheMicore160is.312"therefore
round up to nearest standard thickness available which is 3/8” (.375”)
Note: When installing your fireplace insert with a positive flue connec-
tion, be sure to leave the insulation off the surround panels (flanges) and
leave a 1/4” (6 mm) airspace insulation off the surround panels and the
facing of your fireplace.
Listed Material
k (per inch) r (per inch)
Listed Min. Thickness
1. READ ENTIRE INSTALLATION INSTRUCTIONS.
2. CheckallREqUIREDCLEARANCESasspecifiedintheprevioussection
(Page 7) of this installation and operation manual.
3. Wear gloves during installation in case of sharp edges on the fireplace
insert and it’s parts.
Listed Material
.84
1.19
3/4" (.75")
KL
rL
TL
** Approved Alternate Materials for Floor/Hearth Protection
Alternative Materials
Thermal Values
Minimum Thickness
(rounded to nearest 1/8 inch)
4. Open or remove the existing fireplace damper. Make sure the damper
cannot fall closed.
k (per inch) r (per inch)
Min. Thickness
KM
rM
TM
5. Install the two 1/2” x 3” (13 mm x 76 mm) leveling bolts -heads up- a
few turns in the leveling nuts on each side of the outer chamber of
the insert at the lower rear corners.
Kaowool M Board
.47
.35
2.13
2.86
.42" (1/2")
.31" (3/8")
Micore 160™
U.S. Gypsum
6. Position the insert in the center of the fireplace opening and push it
back until the surround brackets are approximately 2” (51 mm) away
from the fireplace front.
7. Install the side surround panels and push the insert up snug against
thefireplaceface. Thenwiththelocationselectedremovethesurround
panels and level the fireplace insert with the leveling bolts using a 3/4”
(19 mm) socket, extensions (to reach the bolt head) and a ratchet.
8. Glue the insulation around the outer edge of both the top and side
surround panels.
Micore 300™
.46
2.17
.52
.41" (1/2")
U.S. Gypsum
Durock™ Cement Board
U.S. Gypsum
1.92
1.71" (1-3/4")
Hardibacker™
1.95
2.30
2.82
.51
.43
.35
1.74" (1-3/4")
2.05" (2-1/8")
2.52" (2-5/8")
Hardibacker 500™
Cultured Stone Hearth-
stone™
9. Install the surround panels loosely, align and tighten. Check for a
tight fit against the fireplace.
10.Install the brick and baffle as per instructions on Page 6.
Wonderboard
3.23
.61
.31
2.88" (3")
.54" (5/8")
Super Firetemp M
Johns-Manville
1.64
Super Firetemp L
Johns-Manville
.54
1.85
.48" (1/2")
Face brick
9.00
5.00
5.00
12.5
~11
.111
.20
8.04" (8-1/8")
4.46” (4-1/2")
4.46” (4-1/2")
11.16" (11-1/4")
9.82" (9-7/8")
Common brick
Cement mortar
Ceramic tile
Marble
.20
.08
~.09
Table 3 - CANADA REQUIREMENTS
9
Download from Www.Somanuals.com. All Manuals Search And Download.
A full chimney liner
is recommended
POSITIVE FLUE CONNECTION
A positive flue connection is providing a seal between the vent pipe or
liner and the existing fireplace chimney for the purpose of preventing
room air passage to the chimney cavity of the fireplace. There are dif-
ferent approved methods to achieve this. See Direct Connect Positive
Flue Connection on this page.
Fireplace
Chimney
Must extend starter
section past the damper
area as a minimum
Whencreatingapositiveflueconnection, apositiveflueconnectorring
kit is required (sold separately - see Figure 8). The connector ring kit
(listed below) provides a means to directly attach rigid pipe or a flex
pipe adaptor to the flue outlet.
u
71161 - 6" Positive Flue Connector Ring Kit
Install connector ring kits per instructions provided in kits
Side View
of Insert
Rigid Pipe, Offset Box or
Flex Pipe Adaptor
A non-combustible seal is required at the damper area (to prevent
u
dilution air from entering the chimney). See Direct Connect Positive Flue
Connection on this page. A seal-off plate method is shown here.
Figure 9 - Positive Flue Connection
Top of Insert
In Back
Cat. No. H6832, 1/4” to 6-1/4” adjustable
Positive Flue
Connector Ring
}
Cat. No. H6833, 6” to 13” adjustable
(sold separately)
3-3/4”
1-1/2”
v
2-1/8”
C/L
Figure 8 - Connector Ring Kit
5-1/8”
6”
C/L
Direct Connect Positive Flue Connection
Required in Canada
1-1/2”
w
H6832 - 17”
H6833 - 22”
See the following instructions for approved methods of achieving a
positive flue connection - See Figure 9.
SIDE VIEW
A qualified installer should evaluate the existing fireplace to determine
the best method for achieving a positive flue connection between the
vent pipe or liner and the existing fireplace chimney. The most common
method for achieving a positive flue connection in masonry fireplaces
is to secure a seal-off plate (i.e. 22-gage sheet steel) in the fireplace
throat using masonry screws. Other acceptable methods include packing
noncombustible material (i.e. high temp fiberglass or ceramic insulation)
around the vent pipe or using a flue adapter. Whatever “seal off” method
is used, it must effectively seal the area to prevent room air passage to
the chimney cavity of the fireplace.
w
v
14-1/16”
6” Dia.
6” Dia.
Offset Boxes
Offsets can be handled using an offset box (it aligns flue outlet of insert
with the fireplace flue (see Figure 10). Care should be used to ensure
that this adjustable offset box is oriented so it does not angle down when
positioned on the insert flue outlet (level or slightly up at the outbound
end is recommended).
TOP VIEW
vTop 6” collar attaches to rigid pipe or flex liner.
wBottom 6” collar attaches to connector ring on insert flue outlet.
Figure 10 - Offset Box Dimensions
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEARANCE TO COMBUSTIBLES
INSTALLATION PROCEDURE - FACTORY-BUILT ZERO
CLEARANCE FIREPLACES
See “Required Clearances” on Page 7.
FIREPLACE PRE-INSTALLATION PREPARATION
Fireplace and Chimney Requirements
This appliance must only be installed in a zero clearance factory-built
fireplace using 6” (152mm) stainless steel pipe extending from the
insert’s flue into the chimney of the fireplace. For optimum safety and
performance we recommend a full length stainless steel liner directly
connected to the insert’s flue outlet.
NOTE: LENNOX HEARTH PRODUCTS RECOMMENDS PROFES-
SIONALINSTALLATIONBYALICENSEDANDBONDEDINSTALLER.
SEE YOUR DEALER FOR RECOMMENDATIONS. IMPROPER
INSTALLATION OR MIS-USE WILL VOID YOUR WARRANTY AND
CREATE A SERIOUS SAFETY HAZARD.
This appliance must only be installed in a zero clearance factory-built
fireplacethatisstructurallysound.Fireboxesorchimneysthathaveflaws,
burnouts, or warping must be replaced or repaired prior to installation.
Check with your fireplace manufacturer if any problems exist.
Remove any doors or screen materials from the fireplace opening. Re-
move the damper mechanism completely. Also remove grates or ember
catches inside the fireplace hearth. If your fireplace is equipped with a
smoke shelf or baffle and if it interferes with the installation it may be
removed. Side and rear refractory may also be removed, if necessary,
to facilitate installation. No modifications shall be done unless allowed
on the previous list. Retain all removed parts, they must be reinstalled
before the fireplace can be used in it’s original condition.
All convection vents and louvers must be left unmodified and unob-
structed.
This appliance can only be installed in the following brands of factory-
built zero clearance fireplaces: LENNOX, SUPERIOR, HEATILATOR,
MAJESTIC, MARTIN, PREWAY, MARCO, TEMCO and FMI.
INSERT PRE-INSTALLATION PREPARATION
The fireplace cavity must be 36” (914 mm) in width, 21” (533 mm) in
height and 14” (356 mm) in depth. Installation in larger size fireboxes
of the same brands is permissible.
Install the two 3” (76 mm) long bolts (with the head up) through the nuts
attached to the insert on the lower rear corner of each side. This will allow
you to level the insert when placed into the fireplace.
Measure from the front of the top surround mount to the center of the
flue. Determine if there is an alignment problem in connecting a liner
from the chimney to the insert’s flue. If there is an alignment problem,
connection can be made using a short piece of stainless flex or a stain-
less steel offset box (available from your dealer). Before installing the
liner, make any attachment brackets or drill any holes in the liner, offset
box, or insert. Once installed, it may be difficult or impossible to drill
additional holes.
Installations into other brands of the same size is permissible only with
approval from local building officials.
Modifications allowed to the factory-built fireplace are as follows:
- Remove the damper
- Remove the smoke shelf or smoke baffle
- Remove ember catches
- Remove viewing screen/curtain
- Remove side and rear bricks
- Remove the fire grate
FACTORY BUILT FIREPLACE WARNING TAG
- Remove doors
The fireplace must not be altered, except for the exceptions listed
below. The permanent metal warning label provided must be attached
to the back of the fireplace, stating that the fireplace may have been
altered to accommodate the insert, and must be returned to original
condition for use as a conventional fireplace. The following modifica-
tions of factory built fireplaces are permissible: removal of damper,
removal of smoke shelf or baffle, removal of ember catches, removal
of fire grate, removal of viewing screen/curtain, and removal of doors.
The factory built chimney must be listed per UL 127 (US), and meet type
HT requirements of UL 103 (US). Factory built fireplace chimneys tested
to UL 127-1998, may be at the fireplace manufacturer’s option, tested to
the same criteria as UL 103 HT requirements. If the chimney is not listed
as meeting HT requirements, or if the factory built fireplace was tested
prior to 1998, a full height listed chimney liner must be installed from
the appliance flue collar to the chimney top. The liner must meet type
HT requirements (2100ºF) per UL 1777 (US). The liner must be securely
attached to the insert flue collar and the chimney top. To prevent room air
passage to the chimney cavity of the fireplace, seal either the damper area
around the chimney liner with high temperature sealant or the fireplace
front with fiberglass batting.
Note: Secure the tag using screws or nails to the fireplace.
WARNING
THIS FIREPLACE HAS BEEN ALTERED TO
ACCOMMODATE A FIREPLACE INSERT AND
SHOULD BE INSPECTED BY A qUALIFIED
PERSON PRIOR TO RE-USE AS A
CONVENTIONAL FIREPLACE.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
POST INSTALLATION CHECKS
CHIMNEY LINER INSTALLATION
Remove the existing chimney cap and install a stainless steel liner into
the chimney (if a special section has been used or drilled to attach to the
insert, it must be the bottom piece). The next piece should be a dripless
slip joint, followed by the rest of the chimney liner. Fasten the chimney
at the top when it is positioned so that the slip joint will allow the lowest
piece to slide up enough to clear the insert during installation. Insulate
the top four to six feet between the liner and the chimney to prevent heat
loss. Install the cap and flash if necessary to prevent water or creosote
from entering the chimney’s venting system.
1. Check that all chimney pipe joints are securely fastened.
2. Be sure all roof flashings are watertight (if applicable).
FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES,
HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION
INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR
FIRE MARSHAL BEFORE STARTING A FIRE IN YOUR STOVE OR
INSERT. NOTIFY YOUR INSURANCE COMPANY.
From inside the fireplace firebox, attach any adaptors or flue offsets and
slide the liner up as far as necessary for the bottom piece to clear the
insert during installation.
InCanada,Thisfireplaceinsertmustbeinstalledwithacontinuouschimney
liner of 6” diameter extending from the fireplace insert to the top of the
chimney. The chimney liner must conform to the Class 3 requirements
of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or
Factory-BuiltChimneysandVents, orCAN/ULCS640, StandardforLining
Systems for New Masonry Chimneys.
INSTALLING THE INSERT
Place the insert into the fireplace, making sure to center it side to side.
Slide the insert in until the surround mounts are approximately 1/2” (13
mm) from the face of the fireplace where the surround panels cover.
Lower the chimney and make attachment to the insert. Level the fireplace
insert by using a 3/4” socket and a long extension and adjusting the bolts
on either side of the insert.
Install the side surround panels with the screws supplied. Push the insert
in until there is approximately a 1/4” (6 mm) gap between the back of the
surround panels and the face of the fireplace. Before installing the top
surround panel, make sure all connections are tight and that no part of
the insert or chimney is touching the firebox or chimney in the fireplace.
There must be a minimum of 1” (25mm) clearance between the fireplace
insert and the zero clearance fireplace. Install the top surround panel.
Ifadditionalsupportisnecessary,factorypunchedholesinthefrontcorners
of the bottom air chamber will accept leveling legs. Carefully measure the
distance from the hearth protection to the bottom of the fireplace insert.
Use3/8”diameterboltsthatare1/2”(13mm)longerthatthedistancejust
measured. Thread a nut onto the the bolt approximately 1” (25 mm). Lift
the fireplace insert slightly and insert a bolt into each hole and then thread
the nut up the bolt until the front is securely supported. Install another
nut onto the bolt through the air space in the fireplace insert and tighten
securely. If desired an insert front support, Part# H5296, is available to
fill the space between the insert and the hearth protection.
Install the brick and baffle as per Page 6.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
STARTING AND MAINTAINING A FIRE
OPERATING HINTS
1. Burnonlydry,well-seasonedwoodformaximumheatoutput.Insome
states it is illegal to burn wet wood or anything other than clean, dry
wood products.
Be sure to clean plated accessories with a household type
cleaner and a very soft cloth to remove any fingerprints and
residues prior to the first fire.
2. Your fireplace insert is designed to operate with the door closed!
Operate only with the door shut tightly at all times except when
loading wood and possibly on start up to establish a draft. Never
leave the unit unattended while the front door is slightly opened.
3. DONOThitormovethebaffleboardwhileloadingwood.Occasionally
check the baffle. Make sure the baffle blankets are always flush with
the front of the baffle boards. Loading oversized logs may dislodge
the baffle boards.
4. CAUTION: THE DRAFT CONTROL MUST BE FULLY OPEN
BEFOREOPENINGTHEDOORTOAVOIDPOSSIBLECOMBUS-
TION FLASH!! (Ignition of hot volatile gases as the door is opened).
5. Feeding excessive amounts of fuel to the fireplace insert should be
avoided. It is important to supply it with sufficient draft and fuel to
maintain a moderately hot fire. If, during overnight burns, heavy
creosote deposits develop inside your fireplace insert and on the
door, the draft is set too low - review your burning habits!
1. NEVER USE FLAMMABLE LIqUIDS TO START OR REKINDLE
A SOLID FUEL FIRE!!
2. Fully open the primary draft control by pulling the 1” plastic knob
out on the left side (lower front corner) until it stops (away from the
fireplace insert). This control determines the amount of air entering
the fireplace insert. Pushing it toward the fireplace insert reduces the
burn rate in the firebox. For your convenience, the rod on this control
is marked with four grooves to assist you in obtaining repeatable
burn rates.
3. Place a small amount of crumpled paper in front of the firebox and
cover it with a few pieces of kindling.
4. Light the paper and allow sufficient time for the kindling to become
fully engulfed in flames. You will now close the wood units front door.
(Your wood units front door may or may not need to be left slightly
open during this start up process, this depends on the stove model
and the amount of draft present. Do not leave the unit unattended
while the front door is slightly open) Once kindling is burning well,
larger pieces of wood may be added, then the door should be fully
closed if there was the need to keep it slightly open during start up.
CAUTION
Be careful not to abuse door assembly by striking or
slamming it. If the door assembly or glass is broken or
damaged, they must be replaced with factory original
parts before heater can be safely operated. Use only
components provided by the manufacturer as replace-
ment parts.
DO NOT LEAVE THE APPLIANCE UNATTENDED WHILE THE
FRONT DOOR IS SLIGHTLY OPEN.
CAUTION: Do Not alter the adjustment range of the draft
control for increased firing for any reason.
OK
Operate only with fuel door and ash drawer closed. Maintain
allsealsingoodcondition.Donotoperatewithbrokenglass.
Do Not build the fire too close to the glass.
Donotoperatetheappliancewiththedooropenorajarother
than possibly during start up to create a draft (Do not leave
the unit unattended while the front door is slightly open dur-
ing start up). Operating the appliance with the door open
other then in initial start up if needed will produce extreme
temperatures within the appliance. Damage caused from
over-firing is not covered under the manufacturers limited
warranty.
5. For best results, use smaller pieces of wood to get the insert tem-
perature very high before loading larger wood for sustained burns.
If necessary, crack the door to allow ignition of the fuel charge. Do
not leave the unit unattended while the front door is slightly open.
Now you can add larger pieces of wood and after several minutes of
high burn, set the left control for the desired heat output. Check the
exhaust in about 15 to 20 minutes. Large amounts of smoke indicate
an improper burn setting (either too high or too low). Adjust and
recheck in 5 to 10 minutes.
Figure 11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
BLOWER OPERATION
Blower Operation
The blower can be operated manually or automatically (blower will
turn on when the insert is hot and turn off when the insert is cool).
The rocker switch on the control panel allows you to select between
manual operation or automatic operation as follows (see Figure 10):
MANUAL OPERATION: Turn rocker switch to the manual position (up)
and adjust rheostat knob to the desired speed. The blower will have to
be manually turned “OFF” by rotating the rheostat knob counterclock-
wise until it clicks.
Manual / Auto
Rocker Switch
Blower Speed Control
Knob (rheostat)
Figure 11 - Blower Controls
AUTO OPERATION: Turn rocker switch to the “AUTO” position and
the rheostat to the ON position (rotate rheostat knob clockwise until it
clicks). When the insert warms up, the blower will automatically turn
on (adjust rheostat knob to the desired speed setting). When the insert
cools down, the blower will automatically turn off.
WARNINGS
The blower must be plugged directly into a properly
groundedthree-prongreceptacle,120VAC,60Hz,single
phase. Do not cut or remove the grounding prong from
this plug. Do not route power cord under or in front of
appliance.
Rheostat Operation - The highest blower speed is obtained by turning
the rheostat knob clockwise until it clicks “ON”, then rotate towards
“HIGH” to increase blower speed. Rotate the knob clockwise for a
lower speed. To turn off, continue to rotate the knob counterclockwise
until it clicks “OFF.”
Installation must be in accordance with National Elec-
trical Code, ANSI/NFPA 70 - latest edition. In Canada,
the current CSA C22-1 Canadian Electrical Code - latest
edition.
Blower Operation Guidelines
While in auto operation mode, the blower will turn off and on based on
the temperature of the appliance. Auto operation ensures there is suffi-
cient heat build-up to warm the air being moved by the blower before the
blower is turned on. Likewise, when the appliance cools off, the blower
is turned off to prevent circulating cool air. Depending on the size and
DANGER: Disconnect power before servicing blower.
intensity of the fire it may be necessary to adjust the blower speed ac- TCH CONDITIONS
AUTO-RESET
TEMPERATURE
SWITCH N/O
cordingly to ensure un-interrupted blower operation. For example a small
OOM TEMPERATURE
fire may require a slower blower speed to keep the heat output by the
blower consistent. If the blower is operated in manual mode, it may be MALLY CLOSED
necessary to adjust the blower speed as the fire begins to burn down and
the appliance is no longer hot enough to effectively heat the air moved MALLY OPEN
by the blower. If the air coming from the blower feels cool, one shouldMALE DISCONNECT
TWO POSITION
SWITCH
MANUAL/TEMPERATURE
RED
YLW
either decrease the blower speed or stoke the fire to build up more heat.
LE DISCONNECT
D CONNECTION
RED
RED
WHT
GRN
BLK
POWER CORD
SPEED
CONTROL/OFF
ROOM AIR
BLOWER
NOTE: SWITCH CONDITIONS
= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION
GIVEN AT ROOM TEMPERATURE
N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN
W
Figure 12 - Blower Wiring Schematic
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
ACHIEVING CLEAN, LONG BURNS
OPERATING TECHNIqUES AND HINTS
Recentdevelopmentsinwood-burningtechnologyhavemadewood-burn-
ingacleanerandmoreconvenientwaytoheatyourhome.Overallefficiency
in a wood-burning appliance is a combination of combustion efficiency
and heat transfer efficiency. Whether heating your entire home or just a
room or two, your understanding of how to best operate your stove or
insert will enhance its overall efficiency and performance. What this can
mean to you is longer, cleaner burns, less wood use and more heat.
To achieve long burn times, after having thoroughly preheated the
fireplace insert, let the fireplace insert top cool down to 275 to 400
degrees (on Elites, locate thermometer on the face of the insert just
above the door). Now load the firebox and set the draft control. At this
point, you may need to burn the fireplace insert with the draft open for
a few minutes to ignite the wood. All Lennox Hearth Products stoves
and inserts are EPA tested for emissions at low burn with the air control
completely closed. Whether or not you should burn your fireplace insert
withtheaircontrolcompletelyclosedwilldependonthefollowingfactors:
GETTING THE MOST OUT OF YOUR FIREPLACE INSERT
•
•
•
•
•
How you load your wood
Your chimney type, height and draft
Your wood type and its moisture content
The temperature of the fireplace insert
Which model stove or insert you have
The following sections will outline techniques you can use to “get the
most out of your fireplace insert.” Please read them carefully.
MAXIMIZING YOUR FIREPLACE INSERT’S OVERALL
EFFICIENCY
Experimentwithdifferentloadingconfigurationstoachievelongerburns.
Tryloadingthewoodfromsidetosideandnestingitintheashestoprevent
airflow under and around the wood. Fresh wood should be loaded to the
back of the firebox or to the sides. Hot coals or half burned wood should
be brought toward the front of the firebox. The way you load your wood
can seriously affect burn times. If the new load does not ignite within a
few minutes, try crisscrossing the load to allow more airflow around the
fire, or try a slightly hotter fireplace insert temperature.
It is important to know that for high, combustion efficient, clean burns,
you will need to have sufficient temperatures inside the firebox for
thorough combustion. The best method for determining if you have
sufficient temperatures is to watch the brick lining in your firebox. When
you first light your fireplace insert, the bricks will turn a dark brown or
black. After 20 to 30 minutes of a hot fire, most of the bricks should
return to near their original light brown or yellow color. This means the
bricks have reached a high enough temperature for your fireplace insert
to achieve high combustion efficiency.
Determining the lowest setting for efficient low burns. This will require
some experimentation on your part. Try closing the air control all the way
with the fireplace insert temperature at 325 to 350 degrees. If the flames
are completely extinguished, open the air control halfway and then slowly
close it until there is only a small amount of flame. It is important to check
the fireplace insert about 20 minutes after setting the draft control as
it takes this long for the fireplace insert temperature to stabilize. There
should still be some small flames on or above the wood load.
Second and just as important, is achieving a high level of heat transfer
efficiency. Slowing the rate of flow through the stove or insert enhances
heat transfer, thus allowing more time for heat to be transferred into your
home. To do this, be sure to thoroughly preheat your fireplace insert and
then reduce the amount of primary air by closing the draft control (lower
left) to about 1/2 to 3/4 open. This will decrease the excess oxygen in
your flue, which carries heat up your chimney, but should still be enough
air to allow the fireplace insert to produce its maximum heat output.
(More air may produce a lightly greater amount of heat, but will greatly
increase wood consumption). When the area being heated reaches a
comfortable temperature, slow the burn rate by closing the control to
further improve heat transfer.
Use 325 degrees as a starting point. You can try starting temperatures
25degreeshigherorlowertoachievedesiredburntimes,start25degrees
lower if the fireplace insert burns the wood too quickly or 25 degrees
higher if there are no flames in the firebox for more than a few minutes
after loading the wood. You may or may not need to burn the fireplace
insert with the air control open for a few minutes prior to setting the draft
for a low burn, this will depend on the factors mentioned above. Be sure
not to smolder a fire overnight. Check your chimney for large amounts
of smoke as this indicates very poor combustion.
To get the most out of your fireplace insert, you will need to combine
good combustion efficiency with good heat transfer practices. The fol-
lowing are some tips on how to operate your fireplace insert to achieve
the highest overall efficiency.
1. Thoroughly preheat your fireplace insert before slowing the burn rate
by closing the draft control.
2. Measure the fireplace insert temperature at the hottest point on
the fireplace insert top or face. Use this information to repeat burn
rates.
3. Once preheated, add wood (if needed) and partially close the draft
control (lower left).
4. Operateyourfireplaceinsertasmuchaspossibleinthelowtomedium
burn ranges.
5. Do not lower the draft setting so low as to completely extinguish
the flames in the firebox. Check for at least some small flames 20
minutes after setting the draft control.
6. Do not continually operate your fireplace insert in the high (wide
open) setting. This wastes wood by carrying a great deal of heat up
the chimney and can damage your fireplace insert and chimney.
7. Go outside and check your chimney. More than a very small amount
of smoke indicates wasted heat, creosote build up and pollution.
It is important to realize that stove technology has changed. Stoves
and fireplace inserts have changed a great deal in the last few years. This
has led to substantial changes in the methods of operation in new stoves
as compared to older stoves. In old stoves without full brick linings and
ceramic insulation, the rule was “get the stove as hot as possible before
setting the draft on low for overnight burns.” On newer, high technology
Lennox Hearth Products stoves, this is not necessary. Although it is still
important to have the stove hot enough to burn efficiently, it will require
less preheating. Once you have determined your optimum operating
temperatures for various burn rates, we believe you will find your stove or
fireplaceinsertanextremelyconvenientwaytoachieveyourheatingneeds.
Do not reload the fireplace insert for long burns when the stainless
secondary tubes or baffles are glowing red, or when the fireplace
insert is uncomfortably hot to load. This indicates the fireplace insert
is too hot to load for a long burn. Also, do not load wood for a long burn
on a deep bed of hot coals. Try stirring the coals a few minutes before
loading the fireplace insert for a low burn to allow some of the unburned
coals time to burn.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
CAUTION
DOOR HINGES: If door hinges need lubricating, use an anti-seize com-
pound (never use oil) available from your Lennox Hearth Products dealer.
Cleaning Glass: Ensure appliance is cold prior
to cleaning glass. A commercial glass cleaner
designed for stoves is recommended. Do not use
abrasivecleaners.Donotcleanwithanymaterials,
which may scratch or otherwise damage the glass.
Scratches on the glass can develop into cracks or
break. Inspect the glass regularly. If you detect a
crack, extinguish the fire and contact your dealer
for a replacement.
DOOR LATCH: If your door latch fails to latch tightly and the gasket is in
goodcondition,placealengthofpipe(cheaterbar)overtheinsideportion
of the door handle and bend slightly toward the door until the proper
adjustment is obtained. If the door handle does not close easily, apply
high temperature anti-seize to the striker.
DOOR GASKET: Periodically check gasket to make sure it is not over-
compressed. If compressed, replace with a special woven door rope.
(Don’t try substituting rope, only use special Lennox Hearth Products
door rope).
GLASS REPLACEMENT INSTRUCTIONS
PLATED ACCESSORIES: Clean only with a household type glass cleaner
and a very soft cotton cloth Other products may damage plated finish,
paint and gaskets.
Step 1. Remove Door Assembly - Open door to remove E clip from the upper
hinge pin. Remove upper hinge pin by pulling up while holding the op-
posite side of the door. Lift door out of the lower hinge pin and place
face down on a soft surface.
Step 2. Remove Door Back Screws (6 ea.) - Using a 5/32” allen wrench remove
the 6 retainer screws from the faceplate. To locate screws, peel back
the door gasket as necessary.
Step 3. Disassemble Door Assembly - Flip door assembly over to be face up.
Separate faceplate from door back by pulling up on faceplate.
Step 4. Remove Glass - Carefully remove broken glass one piece at a time
(protective gloves are recommended)
Step 5. Install New Glass Assembly - Install the new glass with gasket in recess
on door back (use only factory supplied 5mm ceramic glass. Do not
substitute).
BAFFLE BLANKETS: Your baffle blankets should be inspected during
every chimney cleaning. If the blanket is compressed or heavily stained,
it should be replaced. Heavy creosote stains or matting is an indication
of improper use and your burning habits should be reviewed.
GLASS CLEANING: Only clean glass with products specifically made to
use on wood stoves and fireplace inserts. Other products could damage
gaskets and paint. Never scrape glass with a razor blade. This can pit
the glass and make it impossible to clean in the future.
WINDOW GASKET: The window gasket can be checked by running the
flame of the match near the gasket and around the door. If the flame is
drawn in around the window, the gasket should be replaced.
DOOR HANDLE: Door handle may become tight as you use the fireplace
insert. Freethehandleupbyusingdrygraphitesuppliedwiththefireplace
insert. The directions are included with the graphite.
Step 6. Reinstall Faceplate and Screws - Reinstall faceplate onto door back and
while holding the door assembly together flip the assembly back onto it’s
face. Carefully reinstall the screws. Be very careful not to overtighten the
screws (this could result in glass breakage when the stove or fireplace
insert is hot) and it is highly recommended to use anti seize on the
screws.
Step 7. ReinstallDoor-Setdoorassemblybackintothelowerhingemountwhile
holding the handle side of the door up. Place the upper hinge pin back
in the mount and door assembly. Reinstall the E clip that was removed.
WARNINGS
Inspectandcleanchimneyandconnectorfrequently.
Under certain conditions of use, creosote buildup
may occur rapidly. See Installing the Insert on Page
12 for instructions on removing the appliance for
cleaning (reverse order of instructions).
Door Gasket
Screws and
Washers
GLASS CLEANING GUIDELINES
WARNING: DO NOT CLEAN GLASS WHEN APPLIANCE IS HOT!
Glass on any wood stove or fireplace insert will not stay perfectly clean.
Here are some guidelines for cleaning and caring for the glass:
•
•
Ensure the stove or fireplace insert is cold prior to cleaning glass.
This appliance is designed to provide a flow of air over the inside of
the glass, where along with high heat helps inhibit build-up on the
glass. When build-up occurs, a commercial glass cleaner designed
for stoves is recommended. Regular household glass cleaners will
not clean creosote.
Door Back
Handle Rod
•
•
Do not use abrasives such as steel pads, steel wool or oven cleaner
as they will scratch the glass. Never scrape glass with a razor blade
as this may pit the glass and make it impossible to clean in the future.
Do not use chemical glass cleaners as they may damage the gaskets
or painted surfaces.
Glass
Glass Gasket
TIPS FOR KEEPING THE GLASS CLEAN
•
•
Burn only dry seasoned cord wood. Wet wood = Dirty glass.
A short, hot fire (15 - 20 minutes) may help to clean off some of the
normal buildup. Lower burns = more build-up. Higher burns = less
build-up.
Faceplate
Figure 20
•
•
Keep freshly loaded wood away from the glass.
After reloading, allow all the wood to catch flame before dampering
down the stove or fireplace insert.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Problem
Solution
POOR DRAFT:
Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor
drafts. Remember, the fireplace inserts’ draft depend solely on the natural draft of the chimney (See Draft Requirements
on Page 4). If your fireplace insert is not drafting properly, your chimney is the problem. All stoves and fireplace inserts
are thoroughly tested to ensure proper draft with the correct size chimney flue.
EXCESSIVE DRAFT:
DIRTY GLASS:
With better chimneys being more common, excessive draft can be an issue. Alleviate excessive draft by slowing the
burn rate of the fireplace insert once it has reached proper operating temperature (See Maximizing Your Fireplace
inserts Overall Efficiency on Page 15).
1) Burn smaller, hotter fires and check to make sure you are not setting the draft down too far with the draft control.
2) Make sure your wood is well seasoned and dry (not open to rain - see Creosote and Fuel sections on Page 5).
3) See Poor Draft section (above) and Clean Glass (above).
SMOKES WHEN
DOOR IS OPEN:
1) If smoke is entering the room, check to make sure your baffle boards are properly installed
and that the baffle blankets are pushed back flush with the front of the baffle boards.
2) Check the chimney for blockage due to creosote (see Creosote section on Page 5).
3) Check draft (See POOR DRAFT section above).
WOOD BURNS
TOO FAST:
1) The draft control must be closed further.
2) Add fuel at lower firebox temperatures.
3) Load wood side to side and reduce the flow of air under wood.
4) The door seal may need replacing, check for leakage.
5) See “Excessive Draft.”
POOR HEAT
OUTPUT:
1) Check your wood. Wet, moist, unseasoned wood will not produce heat.
2) Your fireplace insert needs to be seasoned (moisture removed from the steel and brick). Continue to burn a fire. It
normally takes from one to three weeks of burning to season your fireplace insert (See Burn-In Period on Page 5).
3) See Excessive Draft section above.
PAINT GIVES OFF
ODOR (smoke):
Paint is tempering-in. Burn only moderately hot for the first few days until paint is fully cured.
Then burn a very hot fire to cure any paint that may not easily cure. Open windows or door to ventilate (See Burn-In
Period on Page 5).
17
Download from Www.Somanuals.com. All Manuals Search And Download.
DO’S AND DON’T
DO NOT:
DO NOT:
DO NOT:
DO NOT:
Install or operate this fireplace insert before reading this manual.
Close the draft beyond the point at which the flames are completely extinguished.
Open the fireplace insert door without fully opening the draft first.
Burn driftwood or wood that has been in salt water. This includes some mill ends and scrap lumber that has been floated in salt water
on the way to the mill. (This will void your warranty).
DO NOT:
DO NOT:
DO NOT:
Handle the plated faceplate unnecessarily. Use the door handle only.
Force oversized logs into the firebox as this may dislodge the baffle assembly.
Close the door tightly during Burn-In period.
DO:
Be sure to clean any fingerprints from the Gold or Nickel faceplate before burning the fireplace insert. Clean the Gold or Nickel door only
with a household type glass cleaner and a very soft cloth.
DO:
DO:
Consult local building department if other than recommended clearances are desired.
Read instructions for the baffle boards and baffle blankets occasionally to ensure you have not bumped or moved them out of place when
loading wood.
DO:
DO:
DO:
DO:
Check the chimney and baffle monthly to make sure they are clean.
Burn seasoned, dry wood only! (RAIN = WET WOOD)
Open the door frequently during Burn-In period to keep gasket from adhering to the curing paint.
Enjoy the warm feeling of your new Lennox Hearth Products appliance.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
USB BLOWER PARTS
REPLACEMENT PARTS - MODELS C210, CA210 AND SWI210
15
16
17
18
H8067 UHPII Wiring Harness
H5655 UHPI & UHPII Blower Speed Control
H8068 Snap Switch Bracket w/ hardware
H8082 Replacement Power Cord
ContactanLennoxHearthProductsdealertoobtainanyofthese
parts.Neverusesubstitutematerials.Useofnon-approvedparts
can result in poor performance and safety hazards.
H8074 UHPII Blower Cage-Snap Switch/ Black
H8075 UHPII Blower Cage-Snap Switch/ Gold
H8076 UHPII Blower Cage-Snap Switch/ Nickel
H8077 UHPII Blower Cage-Snap Switch/ Brushed Gold
H8078 UHPII Blower Cage-Snap Switch/ Brushed Nickel
H8064 Snap Switch w/ Gasket and Hardware
H8066 Control Switch (Manual, Off, Automatic)
C/A210 AND SWI210 INSERT PARTS
FRONT DOOR PARTS LIST
19
Item #
Cat. No.
Description
1
2
3
4
5
6
7
8
H5639 Door Rope Kit, 7/8” Dia. (6’ 2”)
H5629 Upper Hinge Pin
29
32
H5626 Upper Hinge Pin E-Clip
H5628 Lower Hinge Pin
H5646 Lower Hinge Pin Copper Washer
H5640 Glass Gasket Kit (8’ 4”)
71139 Large Flange Screw/ Black - Seven Needed
H5294 Large Flange Screw/ Gold - Seven Needed
H5295 Large Flange Screw/ Nickel - Seven Needed
33
34
H5577 Set of 6 screws and 6 washers for door assembly
H5654 Spring Handle / Nickel
H8079
C/A210 Nameplate Kit w/ Hardware - Nickel
(1 ea. Lennox & 1 ea. Country)
H5653 Spring Handle / Gold
H8080
C/A210 Nameplate Kit w/ Hardware - Gold
(1 ea. Lennox & 1 ea. Country)
9
71067 Traditional Door Glass / Plain
71068 Traditional Door Glass / Sailboat
71063 Traditional Door Glass / Cattail
71065 Traditional Door Glass / Evergreen
71066 Traditional Door Glass / Floral
71057 Traditional Door Faceplate / Black
71058 Traditional Door Faceplate / Gold
71059 Traditional Door Faceplate / Nickel
71148 Traditional Door Faceplate / Brushed Gold
71145 Traditional Door Faceplate / Brushed Nickel
71072 Arch Door Glass / Plain
35
36
37
38
39
40
41
42
43
44
45
H5650 Draft Rod Knob
H5645 Side Leveling Bolts - Two Included
H5644 Blower Mounting Bolts - Two Needed
H5612 Firebrick 4-1/2” x 9” (14 per stove)
H5606 Firebrick 4-1/2” x 5-1/2” (4 per stove)
H5605 Firebrick 3” x 9” (2 per stove)
H5611 Firebrick 2-1/8” x 9” (2 per stove)
H5599 Firebrick 1-1/2” x 9” (2 per stove)
H3096 Firebrick 1-1/2” x 5-1/2” (1 per stove)
H5603 Firebrick 1-1/2” x 3” (1 per stove)
10
71073 Arch Door Glass / Sailboat
71069 Arch Door Glass / Cattail
H5571 Complete Baffle/Secondary Burn Tube Assembly
(includes tubes and all mounting hardware)
11
12
71070 Arch Door Glass / Evergreen
71071 Arch Door Glass / Floral
46
47
H8019 Baffle Blankets 15-1/4” x 12-1/2” x 1” - Two
Included
H8018 Baffle Board Kit w/ Baffle Blankets
MISCELLANEOUS PARTS
71060 Arch Door Faceplate / Black
71061 Arch Door Faceplate / Gold
71062 Arch Door Faceplate / Nickel
71147 Arch Door Faceplate / Brushed Gold
71144 Arch Door Faceplate / Brushed Nickel
71052 Dry Graphite (Apply to door handle and door
hinges)
H5633 Anti Seize 2 gram pouch
13
14
H5579 Traditional Door Back w/ Handle (door gasket
included)
H5578 Arch Door Back w/ Handle (door gasket included)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS - MODELS C210, CA210 AND SWI210
47
33
46
34
45
36
36
35
37
37
44
40
40
38
38
38
38
38
42
38
38
41
38
38
38
38
38
42
41
38
38
39
39
43
39
39
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS - MODELS C210, CA210 AND SWI210
Door Parts
2
3
1
2
1
3
14
4
11
5
8
13
6
4
9
5
7
8
6
7
12
10
Blower Parts
29
15
17
16
19
32
18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
BLOWERS
ACCESSORIES - MODELS C210, CA210 AND SWI210
Cat. No.
H7907
H7908
H7909
H7910
H7911
Model
Description
Blower Insert Black
WSINS-BLWR-B-SS
WSINS-BLWR-G-SS
WSINS-BLWR-N-SS
WSINS-BLWR-BN-SS
WSINS-BLWR-BG-SS
Product Reference Information
Blower Insert Gold
Blower Insert Nickle
Blower Insert Br-nkl
Blower Insert Br-gold
Cat. No.
Description
Ship.
Weight
Ship.
Volume
H7891
H7892
H8403
C210T-B, Insert / Traditional Black Door /
Nickel Nameplate
427 lb.
426 lb.
427 lb.
18.30 cu. ft.
18.35 cu. ft.
18.30 cu. ft.
C210A-B, Insert / Arch Black Door / Nickel
Nameplate
MISC. PARTS
71053
71054
H8159
Paint Gold (1/2 Pint)
Paint Nickel (1/2 Pint)
TSPK-B
Paint Gold (1/2 pint)
Paint Nickel (1/2 pint)
SWI210, Insert / Traditional Black Door
Touch-Up Paint , Metallic Black, 12
oz. Aerosol
SURROUND PANELS / TOP AND SIDES (REqUIRED)
H5296
H6832
H6833
71161
FRNT-SPPT
OFFADJFLUEBX6SM
OFFADJFLUEBX6LG
WINS-6FC
Front Support 40”- 48” Width / 8”-
0” Height (ref. form #775305M)
Cat. No.
Model
Description
26-1/2” x 40”:
Top Surround 7-1/2” x 40”
Adjustable Offset Flue Box, 6” Flue
to 6” Exhaust (0-6”)
71038
71033
WFPT0740-L
WFPS0718
Side Surrounds 7-1/2” x 18-3/4”
26-1/2” x 48”:
Adjustable Offset Flue Box, 6” Flue
to 6” Exhaust (6-12”)
6” Positive Flue Connector Ring Kit
(ref. form #775232M)
71039
71034
WFPT0748-L
WFPS1118
Top Surround 7-1/2” x 48”
Side Surrounds 11-1/2” x 18-3/4”
30-1/2” x 40”:
71040
71033
WFPT1140-L
WFPS0718
Top Surround 11-1/2” x 40”
Side Surrounds 7-1/2” x 18-3/4”
30-1/2” x 48”:
71041
71034
WFPT1148-L
WFPS1118
Top Surround 11-1/2” x 48”
Side Surrounds 11-1/2” x 18-3/4”
FACEPLATE KITS
Arch Faceplate, Brushed Gold
H7901
H7902
H7904
H7905
ARCH-FPK-BG
TRAD-FPK-BG-SM Traditional Faceplate, Brushed Gold
ARCH-FPK-G
Arch Faceplate, Gold
TRAD-FPK-G-SM
Traditional Faceplate, Gold
SURROUND TRIM - THESE ARE NOT REqUIRED BUT AN OPTION
71021
71022
71025
71026
71007
71008
71011
71012
71074
71075
71078
71079
WFT2640-B
WFT2648-B
WFT3040-B
WFT3048-B
WFT2640-G
WFT2648-G
WFT3040-G
WFT3048-G
WFT2640-N
WFT2648-N
WFT3040-N
WFT2948-N
Black 26-3/4” x 40”
Black 26-3/4” x 48”
Black 30-3/4” x 40”
Black 30-3/4” x 48”
Gold 26-3/4” x 40”
Gold 26-3/4” x 48”
Gold 30-3/4” x 40”
Gold 30-3/4” x 48”
Nickel 26-3/4” x 40”
Nickel 26-3/4” x 48”
Nickel 30-3/4” x 40”
Nickel 30-3/4” x 48”
22
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY / LISTING LABEL - MODELS C210, CA210 AND SWI210
2011 2012 2013
23
Download from Www.Somanuals.com. All Manuals Search And Download.
3. The part number.
4. The description of the part.
5. The quantity required.
WARRANTY
Your wood appliance is covered by a limited warranty (provided with the
appliance). Please read the warranty to be familiar with its coverage.
6. The installation date of the appliance.
If you encounter any problems or have any questions concerning the
installation or application of this system, please contact your dealer.
Retain this manual. File it with your other documents for future refer-
ence.
LENNOX HEARTH PRODUCTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
1-800-9-LENNOX
REPLACEMENT PARTS
See Page 19 for a complete replacement parts list. Use only parts sup-
plied from the manufacturer.
Normally, all parts should be ordered through your Lennox distributor or
dealer. Parts will be shipped at prevailing prices at time of order.
PRODUCT REFERENCE INFORMATION
Werecommendthatyourecordthefollowingimportantinformationabout
your appliance. If you did not purchase your appliance directly from a
Lennox Hearth Products dealer, then please call 1-800-9-LENNOX for the
name and phone number of your nearest Lennox Hearth Products dealer
who will answer your questions or address your concerns.
When ordering repair parts, always give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
Your Appliance’s Model Number _______________________________________
Your Appliance’s Serial Number________________________________________
The Date On Which Your Appliance Was Installed __________________________
Your Dealer's Name _________________________________________________
Lennox Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2007 by Lennox Hearth Products
P/N 775212M Rev. C 09/2011
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
24
Download from Www.Somanuals.com. All Manuals Search And Download.
|