| KRAMER ELECTRONICS LTD.   USER MANUAL   MODEL:   FC-42   Component to HD-SDI   Converter   P/N: 2900-000384 Rev 3   Download from Www.Somanuals.com. All Manuals Search And Download.   Contents   Figures   FC-42 – Contents   i Download from Www.Somanuals.com. All Manuals Search And Download.   1 Introduction   Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been   providing a world of unique, creative, and affordable solutions to the vast range of   problems that confront video, audio, presentation, and broadcasting professionals   on a daily basis. In recent years, we have redesigned and upgraded most of our   line, making the best even better!   Our 1,000-plus different models now appear in 11 groups that are clearly defined   by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers;   GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5:   Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:   Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9:   Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11:   Sierra Products.   Congratulations on purchasing your Kramer FC-42 Component to HD-SDI   Converter, which is ideal for the following typical applications:      Broadcast and production video studios   Postproduction and duplication studios   Non-linear editing   FC-42 - Introduction   1 Download from Www.Somanuals.com. All Manuals Search And Download.   2 Getting Started   We recommend that you:    Unpack the equipment carefully and save the original box and packaging   materials for possible future shipment    Review the contents of this user manual   user manuals, application programs, and to check if firmware   upgrades are available (where appropriate).   i 2.1   Achieving the Best Performance   To achieve the best performance:    Use only good quality connection cables (we recommend Kramer high-   performance, high-resolution cables) to avoid interference, deterioration in   signal quality due to poor matching, and elevated noise levels (often   associated with low quality cables)     Do not secure the cables in tight bundles or roll the slack into tight coils   Avoid interference from neighboring electrical appliances that may adversely   influence signal quality    Position your Kramer FC-42 away from moisture, excessive sunlight and   dust   This equipment is to be used only inside a building. It may only be   connected to other equipment that is installed inside a building.   ! 2 FC-42 - Getting Started   Download from Www.Somanuals.com. All Manuals Search And Download.   2.2   Safety Instructions   Caution:   There are no operator serviceable parts inside the unit   ! Warning: Use only the power cord that is supplied with the unit   Warning: Do not open the unit. High voltages can cause   electrical shock! Servicing by qualified personnel only   Warning: Disconnect the power and unplug the unit from the wall   before installing   2.3   Recycling Kramer Products   The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC   aims to reduce the amount of WEEE sent for disposal to landfill or incineration by   requiring it to be collected and recycled. To comply with the WEEE Directive,   Kramer Electronics has made arrangements with the European Advanced   Recycling Network (EARN) and will cover any costs of treatment, recycling and   recovery of waste Kramer Electronics branded equipment on arrival at the EARN   facility. For details of Kramer’s recycling arrangements in your particular country   FC-42 - Getting Started   3 Download from Www.Somanuals.com. All Manuals Search And Download.   3 Overview   The Kramer FC-42 is a high performance converter for high definition (HD)   component video (Y, PB, PR). It converts the component video input   (Y, PB, PR) to HD-SDI on two BNC output connectors. The signal is also converted   to an RGB/HV signal on a 15-pin HD computer graphics video connector.   In addition, the FC-42 features:     HDTV compatibility   Multi-standard operation: SDI (SMPTE 259M and SMPTE 344M) & HD−SDI   (SMPTE 292M)           HD resolutions of 720p and 1080i (up to 60Hz) & 1080p (up to 30Hz)   Bi−level and tri−level sync input   No resolution conversion   ProcAmp control with memory for 16 setups   A test pattern generator with eight patterns   Control using the front panel with LCD display and RS−232   A worldwide power supply - 100−240V AC   Standard 19” rack mount size of 1U with included rack “ears”   3.1   Defining the FC-42 Component to HD-SDI Converter   This section defines the FC-42.   4 FC-42 - Overview   Download from Www.Somanuals.com. All Manuals Search And Download.   Figure 1: FC-42 Component to HD-SDI Converter Front Panel   # Feature   Function   1 POWER Switch   SETUP / MENU LCD Display   MENU Button   ENTER Button    Button   Illuminated switch for turning the unit ON or OFF   Displays the setup and the menu   2 3 4 5 6 7 8 9 Press to load and save a set up, and to accept changes   Press to decrease numerical values or select from several definitions   Press to move up the menu list values    Button    Button   Press to increase numerical values or select from several definitions   Press to move down the menu list    Button   LOCK Button   Press and hold for about 3 seconds to lock/unlock the front panel buttons   FC-42 - Overview   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Figure 2: FC-42 Component to HD-SDI Converter Rear Panel   # Feature   Y BNC Connector   Function   10   11   12   13   14   15   16   17   INPUTS   PB BNC Connector   Connects to a component video source   PR BNC Connector   SDI BNC Connector   Connects to an HD-SDI acceptor   OUTPUTS   SDI (bar) BNC Connector   RGB/HV 15-pin HD Connector   Connects to an HD-SDI acceptor (reclocked and equalized)   Connects to an RGB/HV acceptor   RS-232 9-pin D-sub Port   Connect to the PC or the remote controller   AC connector, enabling power supply to the unit   Power Connector with Fuse   6 FC-42 - Overview   Download from Www.Somanuals.com. All Manuals Search And Download.   5 Connecting the FC-42   Always switch off the power to each device before connecting it to your   FC-42. After connecting your FC-42, connect its power and then switch   i on the power to each device.   To connect the FC-42, as illustrated in the example in Figure 3, do the following:   1. Connect a component video source (for example, an HDTV Satellite receiver   source) to the Y, PB, PR INPUT BNC connectors.   2. Connect the OUTPUTS:   . . . Connect the SDI BNC connector to an HD-SDI acceptor (for example,   a non-linear editor)   Connect the SDI BNC connector to an HD-SDI acceptor (for example,   an HD-SDI display)   Connect the RGB/HV 15-pin HD computer graphics video connector to   an RGBHV acceptor (for example, a projector)   4. Connect the power cord (not shown in Figure 3).   8 FC-42 - Connecting the FC-42   Download from Www.Somanuals.com. All Manuals Search And Download.   5.1   Connecting to the FC-42 via RS-232   You can connect to the unit via a crossed RS-232 connection, using for example,   a PC. A crossed cable or null-modem is required as shown in method A and B   respectively. If a shielded cable is used, connect the shield to pin 5.   Method A (Figure 4)—Connect the RS-232 9-pin D-sub port on the unit via a   crossed cable (only pin 2 to pin 3, pin 3 to pin 2, and pin 5 to pin 5 need be   connected) to the RS-232 9-pin D-sub port on the PC.   Note: There is no need to connect any other pins.   5 4 3 2 1 5 4 3 2 1 9 8 7 6 9 8 7 6 PC   Figure 4: Crossed Cable RS-232 Connection   Hardware flow control is not required for this unit. In the rare case where a   controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on   the controller side.   Method B (Figure 5)—Connect the RS-232 9-pin D-sub port on the unit via a   straight (flat) cable to the null-modem adapter, and connect the null-modem   adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually   contains all nine wires for a full connection of the D-sub connector. Because the   null-modem adapter (which already includes the flow control jumpering described   in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to   decide whether to connect only these 3 pins or all 9 pins.   5 9 4 8 Null-Modem   Adapter   3 to PC   7 2 6 1 Figure 5: Straight Cable RS-232 Connection with a Null Modem Adapter   10   FC-42 - Connecting the FC-42   Download from Www.Somanuals.com. All Manuals Search And Download.   6 Using the FC-42 Component To HD-SDI   Converter   This section describes how to:     6.1   Locking the Front Panel   To prevent changing the settings accidentally or tampering with the unit via the   front panel buttons, lock your converter. Unlocking releases the protection   mechanism.   Even though the front panel is locked you can still operate via RS-232.   To lock the converter:    Press the LOCK button for more than three seconds, until the LOCK button   is illuminated   The front panel is locked. Pressing a button has no effect other than causing   the LOCK button to flash   Warning that you need to unlock to regain control via the front panel.   To unlock the converter:    Press the illuminated LOCK button for more than three seconds, until the   LOCK button is no longer illuminated   The front panel unlocks   6.2   Operating the FC-42 HD-SDI to Component Converter   The converter can save and load up to 16 setups via the converter menu. To use   the menu, press the:     MENU button to start or exit the menu   ENTER button to enter a submenu, load a setup, accept changes and reset   to the default settings     and  buttons to scroll through the menu and sub-menus   FC-42 - Using the FC-42 Component To HD-SDI Converter   11   Download from Www.Somanuals.com. All Manuals Search And Download.     and  to increase or decrease numerical values or select from several   definitions of a setup   The converter automatically converts the input signal according to the setup   loaded from the menu. The setup is defined via the menu. To operate the   converter, press the MENU button to enter the menu, and load the desired setup   (from 1 to 16). The following table defines the menu items.   # Menu Item   LOAD … SETUP   SAVE SETTING AS   Submenu   Select   From 1 to 16   Notes   Refers to the setup   number (from 1 to 16)   1 2 3 From 1 to 16   SET … STANDARD   AUTO, FORCED   SELECT MODE   4 SET … STANDARD   720p/59, 720p/50,   1080i/60, 1080i/59,   1080i/50,   1080p/30, 1080p/29,   1080p/25, 1080p/24,   1080p/23,   1080sf/30, 1080sf/29,   1080sf/25, 1080sf/24,   1080sf/23   5 6 SET … SYNC TYPE   BILEVEL, TRILEVEL   SET … IMAGE TUNING 1 FACTORY RESET   (enter submenu)   Sets all the image   tuning parameters to   zero   2 BLACK   3 Y-GAIN   4 GAIN   From -32 to 31   From -64% to 63%   From -64% to 63%   From -64% to 63%   From -64% to 63%   From -64% to 63%   From 0 to 155%   5 COLOR   6 B-Y   7 R-Y   8 SHARPNESS   In 5% steps   7 SET … Test signal   NO TEST SIGNAL   1 COLOR BARS 100%   2 Y-SWEEP 30MHZ   3 PULSE 2T AND BAR   4 Y RAMP   5 C-SWEEP 15MHZ   6 SPLIT BARS   7 GRID   8 GRID INVERSE   8 9 SET … Free run mode   BLACK SCREEN, BLUE   SCREEN   SET … Address of   First, Second   machine   12   FC-42 - Using the FC-42 Component To HD-SDI Converter   Download from Www.Somanuals.com. All Manuals Search And Download.   7 Technical Specifications   INPUT:   1 component video - Y, PB, PR, on 3 BNC connectors   OUTPUTS:   2 SDI on BNC connectors   1 RGB/HV on a 15-pin HD connector   OUTPUT LEVEL:   RESOLUTION:   S/N RATIO:   800mVpp   Up to 1080p   49dB unweighted   CONTROLS:   Front panel buttons: MENU, ENTER, menu arrows,   LOCK;   rear panel: RS-232   POWER CONSUMPTION:   OPERATING TEMPERATURE:   STORAGE TEMPERATURE:   HUMIDITY:   100-240V, 50/60Hz, 200mA Max. 12VA   0° to +40°C (32° to 104°F)   -40° to +70°C (-40° to 158°F)   10% to 90%, RHL non-condensing   19" x 7" x 1U (W, D, H) rack mountable   2.6kg (5.7lbs) approx.   DIMENSIONS:   WEIGHT:   ACCESSORIES:   Power cord, null-modem adapter   FC-42 - Technical Specifications   13   Download from Www.Somanuals.com. All Manuals Search And Download.   8 Communication Protocol   The FC-42 is compatible with the protocol (ver 1.2) described below. For RS-232,   a null-modem connection between the FC-42 and controller is used. The default   data rate is 9600 baud, with no parity, 8 data bits and 1 stop bit. All the values   shown are hexadecimal.   Instruction   Byte 1   Byte 2   Byte 3   Byte 4   Notes:   RESET   00   80   80   98+Machine   Addr   REPLY TO   RESET   40   20   60   80   80   98+Machine   Addr   READ LOCAL   PARAMETER   80+Parameter 80   Number   B8+Machine   Addr   REPLY TO READ   LOCAL   PARAMETER   80+Parameter 80+Parameter   Number   B8+Machine   Addr   Data   WRITE LOCAL   PARAMETER   21   61   80+Parameter 80+Parameter   Number Data   80+Parameter 80+Parameter   Number Data   B8+Machine   Addr   REPLY TO   WRITE LOCAL   PARAMETER   B8+Machine   Addr   1 READ GLOBAL   PARAMETER   20   60   80+Parameter 80   Number   98+Machine   Addr   REPLY TO READ   GLOBAL   PARAMETER   80+Parameter 80+Parameter   98+Machine   Addr   Number   Data   WRITE GLOBAL   PARAMETER   21   61   80+Parameter 80+Parameter   Number   98+Machine   Addr   Data   80+Parameter 80+Parameter   REPLY TO   WRITE GLOBAL   PARAMETER   98+Machine   Addr   1 2 Number   Data   SAVE   23   80 + Initial   Setup   80+Destination   Setup Number   98+Machine   Addr   Number   IDENTIFY   MACHINE   3D   3D   81   80   80   98+Machine   Addr   3 4 IDENTIFY   FIRMWARE   VERS.   83   98+Machine   Addr   14   FC-42 - Communication Protocol   Download from Www.Somanuals.com. All Manuals Search And Download.   The following table defines the local parameter data:   Local Parameter Number   Local Parameter Data   Description   # 0 - 720p/60   1 - 720p/59   2 - 720p/50   3 - 1080i/60   4 - 1080i/59   5 - 1080i/50   6 - 1080p/30   7 - 1080p/29   Input Standard   01   8 - 1080p/25   9 - 1080p/24   A - 1080p/23   B - 1080sf/30   C - 1080sf/29   D - 1080sf/25   E - 1080sf/24   F - 1080sf/23   0 - Auto   Mode Input Standard   SYNC Type   02   04   1 - Forced   0 - Bi-Level   1 - Tri-Level   0 - NO TEST SIGNAL   1 - COLOR BAR 100%   2 - Y-SWEEP 30 MHZ   3 - PULSE 2T AND BAR   4 - Y-RAMP   Test Signal   05   5 - C-SWEEP 15 MHZ   6 - RAINBOW   7 - GRID   8 - GRID INVERSE   -32% - +31% (1% step)   -64% - +63% (1% step)   -64% - +63% (1% step)   -64% - +63% (1% step)   -64% - +63% (1% step)   -64% - +63% (1% step)   0% - +150% (10% step)   Black   Y-gain   Gain   08   09   0A   0B   0C   0D   0E   Color   B-Y   R-Y   Sharpness   FC-42 - Communication Protocol   15   Download from Www.Somanuals.com. All Manuals Search And Download.   The following table defines the global parameter data:   Global Parameter Number   Global Parameter Data   Description   # 0 - Off (Default)   1 - On   Panel Lock   00   Machine Address   Setup Number   01   02   0,1   0 - 15   0 - Black Screen (Default)   1 - Blue Screen   0 - 720p/60   Free Run Mode   03   08   09   1 - 720p/59   2 - 720p/50   3 - 1080i/60   4 - 1080i/59   5 - 1080i/50   6 - 1080p/30   7 - 1080p/29   8 - 1080p/25   9 - 1080p/24   A - 1080p/23   B - 1080sf/30   C - 1080sf/29   D - 1080sf/25   E - 1080sf/24   F -1080sf/23   10 - Not Identified   11 - Not Identified   0 - Input Signal is Present   1 - No Input Signal   Input Standard   (Read Only)   (AUTO Mode Only)   Presence of Input Signal   (Read Only)   NOTE 1: These commands are sent by the unit also when Local / Global parameters are changed via the front panel or   as a result of execution of any other command.   NOTE 2: If it is necessary merely to save adjusted parameters in initial setup number (no setup number change), then   the value of byte3 must be equal to the value of byte2 - initial setup number.   NOTE 3: The reply to the Identify Machine command shows the machine name   - 1st byte: 0x7d   - 2nd byte: 0x80 + 0x00 (0 dec)   - 3rd byte: 0x80 + 0x29 (41 dec) - for the unit FC-42   - 4th byte: 0x98   NOTE 4: The reply to the Identify Firmware command shows the firmware version as   - 1st byte: 0x7d   - 2nd byte: 0x80 + the version number prior to decimal point   - 3rd byte: 0x80 + the version number following the decimal point   - 4th byte: 0x98   For example, for version 3.5, the reply would be 0x7d, 0x83, 0x85, 0x98.   16   FC-42 - Communication Protocol   Download from Www.Somanuals.com. All Manuals Search And Download.   Download from Www.Somanuals.com. All Manuals Search And Download.   For the latest information on our products and a list of Kramer distributors,   visit our Web site where updates to this user manual may be found.   We welcome your questions, comments, and feedback.   Web site: www.kramerelectronics.com   E-mail: [email protected]   SAFETY WARNING   Disconnect the unit from the power   supply before opening and servicing   ! P/N:   Rev:   2900- 000384   3 Download from Www.Somanuals.com. All Manuals Search And Download.   |