					30" (76.2 CM) AND 36" (91.4 CM) CLASSIC COMMERCIAL-   
					STYLE DUAL FUEL CONVECTION RANGE WITH STEAM-ASSIST   
					PRODUCT MODEL NUMBERS   
					OVERALL DIMENSIONS   
					A 
					KDRP707R   
					KDRP767R   
					Gas supply: This range is design-certified by   
					CSA International for use with Natural gas or, after   
					proper conversion, for use with LP gas. This range   
					is factory set for use with Natural gas. The model/   
					serial rating plate located on the right vertical   
					surface of the oven door frame has information on   
					the types of gas that can be used. If the types of   
					gas listed do not include the type of gas available,   
					check with the local gas supplier.   
					G 
					O 
					F F   
					O 
					F F F   
					O 
					F F   
					O 
					F 
					F 
					O 
					F F   
					B 
					O 
					F F   
					O 
					F F   
					O 
					F F   
					Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe   
					to the range location. With LP gas, piping or   
					tubing size can be ¹⁄₂" (1.3 cm) minimum.   
					C 
					F 
					If local codes permit, a new CSA design-certified,   
					4 - 5 ft (122 - 152.4 cm) long, ⁵⁄₈" (1.6 cm) or ³⁄₄"   
					(1.9 cm) I.D., flexible metal appliance connector   
					may be used for connecting range to the gas   
					supply line. A ¹⁄₂" (1.3 cm) male pipe thread is   
					needed for connection to the female pipe threads   
					of the inlet to the appliance pressure regulator.   
					D 
					E*   
					A. Backguard (required for some installations)   
					B. 45" (114.3 cm) overall height   
					Electrical: A 4-wire or 3-wire, single phase,   
					240 volt, 60 Hz., AC only electrical supply is   
					required on a separate, 30-amp circuit, fused on   
					both sides of the line. A time-delay fuse or circuit   
					breaker is recommended. The range can be   
					connected directly to the fused disconnect (or   
					circuit breaker box) through flexible, armored or   
					nonmetallic sheathed, copper or aluminum cable.   
					C. 36" (91.4 cm) cooktop height with feet loosened ¾ turn   
					D. 36" (91.4 cm) model: D= 36" (91.4 cm) width   
					30" (76.2 cm) model: D= 30" (76.2 cm) width   
					E. 26½" (67.3 cm) width with control panel, See NOTE*   
					F. ¼" (6.4 cm) spacer   
					G. 9¼" (23.5 cm) backguard height   
					*When installed in a 24" (61 cm) base cabinet with   
					25" (63.5 cm) countertop; front of oven door protrudes   
					1⁷⁄₈   
					" (4.8 cm) beyond 24" (61 cm) base cabinet.   
					CABINET OPENING DIMENSIONS   
					A. 18" (45.7 cm) upper cabinet to countertop   
					B. 36" (91.4 cm) model: B = 28" (71.1 cm)   
					30" (76.2 cm) model: B = 22" (55.9 cm)   
					C. Junction box to be located in this shaded area   
					D. 4" (10.2 cm)   
					E. 20" (50.8 cm)   
					F. 12" (30.5 cm)   
					G. 5½" (14 cm)   
					H. Gas line opening to be located in this shaded area   
					I. 3½" (8.9 cm)   
					O 
					* 
					M 
					L 
					N 
					J. 8" (20.3 cm)   
					K 
					K. 36" (91.4 cm) model: K = 36¼" (92.1 cm)   
					30" (76.2 cm) model: K = 30¼" (76.8 cm)   
					L. 4" (10.2 cm) min. clearance from both sides of range to side   
					wall or other combustible material   
					A 
					M. For minimum clearance to top of range, see NOTE*   
					N. 30" (76.2 cm) model: 30" (76.2 cm) min. upper cabinet width   
					O. 13" (33 cm) max. upper cabinet depth   
					J 
					I 
					*NOTE: Minimum Clearances   
					B 
					30" (76.2 cm) models: 36" (91.4 cm) minimum clearance   
					36" (91.4 cm) models: 42" (106.7 cm) minimum clearance   
					When bottom of wood or metal cabinet is protected by not less than   
					H 
					¹⁄₄" (0.64 cm) flame   
					E 
					retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)   
					stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.   
					D 
					G 
					30" (76.2 cm) models: 42" (106.7 cm) minimum clearance   
					36" (91.4 cm) models: 48" (121.9 cm) minimum clearance   
					Between the top of the cooking platform and the bottom of an unprotected wood or   
					metal cabinet.   
					F 
					C 
					If installing a hood or a microwave hood combination above the range, follow the hood   
					instructions for dimensional clearances above the cooktop surface.   
					Because Whirlpool Corporation policy includes a continuous commitment to improve   
					our products, we reserve the right to change materials and specifications without notice.   
					Dimensions are for planning purposes only. For complete details, see Installation   
					Instructions packed with product. Specifications subject to change without notice.   