Intel Computer Hardware S3420GP User Manual

Intel® Server Board S3420GP  
Technical Product Specification  
Intel order number E65697-003  
Revision 1.0  
August 2009  
Enterprise Platforms and Services Division  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Disclaimers  
Disclaimers  
Information in this document is provided in connection with Intel® products. No license, express  
or implied, by estoppel or otherwise, to any intellectual property rights is granted by this  
document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel  
assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to  
sale and/or use of Intel products including liability or warranties relating to fitness for a particular  
purpose, merchantability, or infringement of any patent, copyright or other intellectual property  
right. Intel products are not intended for use in medical, life saving, or life sustaining applications.  
Intel may make changes to specifications and product descriptions at any time, without notice.  
Designers must not rely on the absence or characteristics of any features or instructions marked  
"reserved" or "undefined." Intel reserves these for future definition and shall have no  
responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.  
This document contains information for a product that is still in development. Do not  
finalize a design with this information. Information provided in this preliminary document may be  
incomplete (as denoted by TBD) or may change. Revised information will be published in a later  
release of this document and when the product is made available. Verify with your local sales  
office that you have the latest datasheet before finalizing a design.  
The Intel® Server Board S3420GP may contain design defects or errors known as errata which  
may cause the product to deviate from published specifications. Current characterized errata  
are available on request.  
Intel Corporation server boards contain a number of high-density VLSI and power delivery  
components that need adequate airflow to cool. Intel’s own chassis are designed and tested to  
meet the intended thermal requirements of these components when the fully integrated system  
is used together. It is the responsibility of the system integrator that chooses not to use Intel  
developed server building blocks to consult vendor datasheets and operating parameters to  
determine the amount of airflow required for their specific application and environmental  
conditions. Intel Corporation cannot be held responsible if components fail or the server board  
does not operate correctly when used outside any of their published operating or non-operating  
limits.  
Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.  
*Other brands and names may be claimed as the property of others.  
Copyright © Intel Corporation 2009.  
Revision 1.0  
iii  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
IntelP®P Server Board S3420GP TPS  
Table of Contents  
1. Introduction ..........................................................................................................................2  
1.1  
1.2  
Chapter Outline........................................................................................................2  
Server Board Use Disclaimer ..................................................................................2  
2. Overview ...............................................................................................................................1  
2.1  
2.2  
Intel® Server Board S3420GP Feature Set..............................................................1  
Server Board Layout................................................................................................3  
Server Board Connector and Component Layout....................................................4  
Intel® Server Board S3420GP Mechanical Drawings ..............................................6  
Server Board Rear I/O Layout ...............................................................................12  
2.2.1  
2.2.2  
2.2.3  
3. Functional Architecture.....................................................................................................13  
3.1  
3.1.1  
Processor Sub-System..........................................................................................14  
Intel® Xeon® 3400 Processor.................................................................................14  
Intel® Turbo Boost Technology ..............................................................................15  
Simultaneous Multithreading (SMT) ......................................................................15  
Enhanced Intel SpeedStep® Technology...............................................................15  
Memory Subsystem...............................................................................................15  
Memory Sizing and Configuration..........................................................................16  
Post Error Codes ...................................................................................................16  
Publishing System Memory ...................................................................................17  
Support for Mixed-speed Memory Modules...........................................................18  
Memory Map and Population Rules.......................................................................18  
Intel® 3420 Chipset PCH........................................................................................21  
I/O Sub-system......................................................................................................21  
PCI Express Interface............................................................................................21  
Serial ATA Support................................................................................................22  
USB 2.0 Support....................................................................................................22  
Optional Intel® SAS Entry RAID Module AXX4SASMOD ......................................23  
Integrated Baseboard Management Controller......................................................23  
Integrated BMC Embedded LAN Channel.............................................................25  
Optional RMM3 Advanced Management Board ....................................................25  
Serial Ports ............................................................................................................26  
Floppy Disk Controller ...........................................................................................26  
3.1.2  
3.1.3  
3.1.4  
3.2  
3.2.1  
3.2.2  
3.2.3  
3.2.4  
3.2.5  
3.3  
3.4  
3.4.1  
3.4.2  
3.4.3  
3.5  
3.6  
3.6.1  
3.6.2  
3.6.3  
3.6.4  
iv  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Table of Contents  
3.6.5  
3.6.6  
Keyboard and Mouse Support...............................................................................26  
Wake-up Control....................................................................................................27  
Video Support........................................................................................................27  
Video Modes..........................................................................................................27  
Dual Video .............................................................................................................27  
Network Interface Controller (NIC) ........................................................................28  
GigE Controller 82574L .........................................................................................28  
GigE PHY 82578DM..............................................................................................28  
MAC Address Definition.........................................................................................28  
Intel® I/O Acceleration Technolgy 2 (Intel® I/OAT2)...............................................29  
Direct Cache Access (DCA) ..................................................................................29  
Intel® Virtualization Technology for Directed I/O (Intel® VT-d) ...............................29  
3.7  
3.7.1  
3.7.2  
3.8  
3.8.1  
3.8.2  
3.8.3  
3.9  
3.9.1  
3.10  
4. Platform Management........................................................................................................30  
4.1  
4.1.1  
4.1.2  
4.2  
Feature Support.....................................................................................................30  
IPMI 2.0 Features ..................................................................................................30  
Non-IPMI Features ................................................................................................31  
Optional Advanced Management Feature Support ...............................................32  
Enabling Advanced Management Features...........................................................32  
Keyboard, Video, Mouse (KVM) Redirection.........................................................32  
Media Redirection..................................................................................................33  
Web Services for Management (WS-MAN) ...........................................................34  
Local Directory Authentication Protocol (LDAP)....................................................34  
Embedded Webserver...........................................................................................34  
Management Engine (ME).....................................................................................34  
4.2.1  
4.2.2  
4.2.3  
4.2.4  
4.2.5  
4.2.6  
4.3  
5. BIOS User Interface............................................................................................................35  
5.1  
5.2  
5.3  
Logo / Diagnostic Screen.......................................................................................35  
BIOS Boot Popup Menu ........................................................................................35  
BIOS Setup utility...................................................................................................35  
Operation...............................................................................................................35  
Server Platform Setup Utility Screens ...................................................................38  
Loading BIOS Defaults ..........................................................................................63  
5.3.1  
5.3.2  
5.4  
6. Connector / Header Locations and Pin-outs....................................................................65  
6.1  
6.2  
6.3  
Board Connector Information.................................................................................65  
Power Connectors .................................................................................................65  
System Management Headers ..............................................................................66  
Revision 1.0  
v
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
IntelP®P Server Board S3420GP TPS  
6.3.1  
6.3.2  
6.3.3  
6.3.4  
Intel® Remote Management Module 3 (Intel® RMM3) Connector..........................66  
LCP / IPMB Header ...............................................................................................67  
HSBP Header ........................................................................................................67  
SGPIO Header.......................................................................................................67  
Front Control Panel Connector..............................................................................68  
Power Button .........................................................................................................68  
Reset Button..........................................................................................................69  
NMI Button.............................................................................................................69  
System Status Indicator LED.................................................................................69  
I/O Connectors.......................................................................................................71  
VGA Connector......................................................................................................71  
Rear NIC and USB connector................................................................................71  
SATA .....................................................................................................................72  
SAS Connectors ....................................................................................................72  
Serial Port Connectors...........................................................................................72  
USB Connector......................................................................................................73  
PCI Express* Slot / PCI Slot / Riser Card Slot /.....................................................75  
Fan Headers..........................................................................................................79  
6.4  
6.4.1  
6.4.2  
6.4.3  
6.4.4  
6.5  
6.5.1  
6.5.2  
6.5.3  
6.5.4  
6.5.5  
6.5.6  
6.6  
6.7  
7. Jumper Blocks....................................................................................................................80  
7.1  
7.1.1  
7.1.2  
7.2  
CMOS Clear and Password Reset Usage Procedure ...........................................81  
Clearing the CMOS................................................................................................81  
Clearing the Password...........................................................................................81  
Integrated BMC Force Update Procedure .............................................................82  
ME Force Update Jumper......................................................................................82  
BIOS Recovery Jumper.........................................................................................83  
7.3  
7.4  
8. Intel® Light Guided Diagnostics........................................................................................84  
8.1  
8.2  
System Status LED................................................................................................84  
Post Code Diagnostic LEDs ..................................................................................85  
9. Design and Environmental Specifications.......................................................................86  
9.1  
9.2  
9.3  
Intel® Server Board S3420GP Design Specifications ............................................86  
Board-level Calculated MTBF................................................................................86  
Server Board Power Requirements .......................................................................87  
Processor Power Support......................................................................................88  
Power Supply Output Requirements .....................................................................88  
Grounding..............................................................................................................89  
9.3.1  
9.4  
9.4.1  
vi  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Table of Contents  
9.4.2  
9.4.3  
9.4.4  
9.4.5  
9.4.6  
9.4.7  
9.4.8  
9.4.9  
Standby Outputs....................................................................................................89  
Remote Sense.......................................................................................................89  
Voltage Regulation ................................................................................................89  
Dynamic Loading...................................................................................................89  
Capacitive Loading ................................................................................................90  
Closed-loop Stability..............................................................................................90  
Common Mode Noise............................................................................................90  
Ripple / Noise ........................................................................................................90  
9.4.10 Timing Requirements.............................................................................................90  
9.4.11 Residual Voltage Immunity in Standby Mode........................................................93  
9.4.12 Protection Circuits..................................................................................................93  
10. Regulatory and Certification Information.........................................................................95  
10.1  
Product Regulatory Compliance............................................................................95  
10.1.1 Product Safety Compliance ...................................................................................95  
10.1.2 Product EMC Compliance – Class A Compliance.................................................95  
10.1.3 Certifications / Registrations / Declarations...........................................................95  
10.1.4 Product Ecology Requirements .............................................................................96  
10.2  
10.3  
Product Regulatory Compliance Markings ............................................................97  
Electromagnetic Compatibility Notices ..................................................................99  
10.3.1 FCC Verification Statement (USA) ........................................................................99  
10.3.2 ICES-003 (Canada) .............................................................................................100  
10.3.3 Europe (CE Declaration of Conformity) ...............................................................100  
10.3.4 VCCI (Japan).......................................................................................................100  
10.3.5 BSMI (Taiwan).....................................................................................................101  
10.3.6 RRL (Korea).........................................................................................................101  
10.3.7 CNCA (CCC-China).............................................................................................101  
Appendix A: Integration and Usage Tips..............................................................................102  
Appendix B: Integrated BMC Sensor Tables........................................................................103  
Appendix C: POST Code Diagnostic LED Decoder .............................................................109  
Appendix D: POST Code Errors ............................................................................................113  
Appendix E: Supported Intel® Server Chassis.....................................................................118  
Glossary...................................................................................................................................119  
Reference Documents............................................................................................................122  
Revision 1.0  
vii  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Figures  
IntelP®P Server Board S3420GP TPS  
List of Figures  
Figure 1. Intel® Server Board S3420GPLX Picture.......................................................................3  
Figure 2. Intel® Server Board S3420GP Layout............................................................................4  
Figure 3. Intel® Server Board S3420GP – Key Connector and LED Indicator IDENTIFICATION.6  
Figure 4. Intel® Server Board S3420GP – Hole and Component Positions..................................7  
Figure 5. Intel® Server Board S3420GP – Major Connector Pin Location (1 of 2)........................8  
Figure 6. Intel® Server Board S3420GP –Major Connector Pin Location (2 of 2).........................9  
Figure 7. Intel® Server Board S3420GP – Primary Side Keepout Zone .....................................10  
Figure 8. Intel® Server Board S3420GP – Secondary Side Keepout Zone.................................11  
Figure 9. Intel® Server Board S3420GP Rear I/O Layout ...........................................................12  
Figure 10. Intel® Server Board S3420GP Functional Block Diagram For S3420GPLX ..............13  
Figure 11. Intel® Server Board S3420GP Functional Block Diagram From S3420GPLC...........14  
Figure 12. Intel® Server Board S3420GP Functional Block Diagram From S3420GPV .............14  
Figure 13. Integrated BMC Hardware.........................................................................................25  
Figure 14. Server Management Bus (SMBUS) Block Diagram...................................................30  
Figure 15. Setup Utility – Main Screen Display...........................................................................39  
Figure 16. Setup Utility – Advanced Screen Display ..................................................................41  
Figure 17. Setup Utility – Processor Configuration Screen Display............................................42  
Figure 18. Setup Utility – Memory Configuration Screen Display...............................................45  
Figure 19. Setup Utility – Mass Storage Controller Configuration Screen Display .....................46  
Figure 20. Setup Utility – Serial Port Configuration Screen Display ...........................................48  
Figure 21. Setup Utility – USB Controller Configuration Screen Display....................................49  
Figure 22. Setup Utility – PCI Configuration Screen Display......................................................50  
Figure 23. Setup Utility – System Acoustic and Performance Configuration Screen Display.....52  
Figure 24. Setup Utility – Security Configuration Screen Display...............................................53  
Figure 25. Setup Utility – Server Management Configuraiton Screen Display............................55  
Figure 26. Setup Utility – Console Redirection Screen Display..................................................56  
Figure 27. Setup Utility – Server Management System Information Screen Display..................58  
Figure 28. Setup Utility – Boot Options Screen Display..............................................................59  
Figure 29. Setup Utility – Delete Boot Option Screen Display....................................................60  
Figure 30. Setup Utility — Hard Disk Order Screen Display.......................................................61  
Figure 31. Setup Utility – CDROM Order Screen Display...........................................................61  
Figure 32. Setup Utility — Floppy Order Screen Display............................................................62  
viii  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
List of Figures  
Figure 33. Setup Utility – Network Device Order Screen Display...............................................62  
Figure 34. Setup Utility – Boot Manager Screen Display............................................................63  
Figure 35. Jumper Blocks (J1A2, J1F1, J1F3, J1F2 and J1F5)..................................................80  
Figure 36. Power Distribution Block Diagram .............................................................................87  
Figure 37. Output Voltage Timing...............................................................................................91  
Figure 38. Turn On/Off Timing (Power Supply Signals)..............................................................92  
Figure 39. Diagnostic LED Placement Diagram .......................................................................109  
Revision 1.0  
ix  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Tables  
IntelP®P Server Board S3420GP TPS  
List of Tables  
Table 1. Intel® Server Board S3420GP Feature Set.....................................................................1  
Table 2. Major Board Components...............................................................................................5  
Table 3. Standard Platform DIMM Nomenclature.......................................................................18  
Table 4. Memory Configuration Table.........................................................................................20  
Table 5. Optional RMM3 Advanced Management Board Features ............................................26  
Table 6. Serial B Header (J1B1) Pin-out.....................................................................................26  
Table 7. Video Modes.................................................................................................................27  
Table 8. Dual Video Modes.........................................................................................................27  
Table 9. BIOS Setup Page Layout..............................................................................................36  
Table 10. BIOS Setup: Keyboard Command Bar........................................................................37  
Table 11. Setup Utility – Main Screen Fields..............................................................................39  
Table 12. Setup Utility – Advanced Screen Display Fields.........................................................41  
Table 13. Setup Utility – Processor Configuration Screen Fields ...............................................42  
Table 14. Setup Utility – Memory Configuration Screen Fields ..................................................45  
Table 15. Setup Utility – Mass Storage Controller Configuration Screen Fields.........................46  
Table 16. Setup Utility – Serial Ports Configuration Screen Fields.............................................48  
Table 17. Setup Utility – USB Controller Configuration Screen Fields .......................................49  
Table 18. Setup Utility – PCI Configuration Screen Fields .........................................................51  
Table 19. Setup Utility – System Acoustic and Performance Configuration Screen Fields ........52  
Table 20. Setup Utility – Security Configuration Screen Fields ..................................................53  
Table 21. Setup Utility – Server Management Configuration Screen Fields...............................55  
Table 22. Setup Utility – Console Redirection Configuration Fields ...........................................57  
Table 23. Setup Utility – Server Management System Information Fields..................................58  
Table 24. Setup Utility – Boot Options Screen Fields.................................................................59  
Table 25. Setup Utility – Delete Boot Option Fields....................................................................60  
Table 26. Setup Utility — Hard Disk Order Fields.......................................................................61  
Table 27. Setup Utility – CDROM Order Fields ..........................................................................61  
Table 28. Setup Utility — Floppy Order Fields............................................................................62  
Table 29. Setup Utility – Network Device Order Fields...............................................................63  
Table 30. Setup Utility – Boot Manager Screen Fields ...............................................................63  
Table 31. Board Connector Matrix..............................................................................................65  
Table 32. Baseboard Power Connector Pin-out (J9A1)..............................................................66  
x
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
List of Tables  
Table 33. SSI Processor Power Connector Pin-out (J9C1)........................................................66  
Table 34. Intel® RMM3 Connector Pin-out (J2C1) ......................................................................66  
Table 35. LPC / IPMB Header Pin-out (J1H2) ............................................................................67  
Table 36. HSBP Header Pin-out (J1J1)......................................................................................67  
Table 37. SGPIO Header Pin-out (J1J3) ....................................................................................67  
Table 38. Front Panel SSI Standard 24-pin Connector Pin-out (J1C1) ......................................68  
Table 39. System Status LED Indicator States...........................................................................70  
Table 40. VGA Connector Pin-out (J7A1)...................................................................................71  
Table 41. RJ-45 10/100/1000 NIC Connector Pin-out (J5A1).....................................................71  
Table 42. RJ-45 10/100/1000 NIC Connector Pin-out (J6A1).....................................................71  
Table 43. SATA Connector Pin-out (J1H4, J1H1, J1G1, J1H3, J1G3, J1F4).............................72  
Table 44. SAS Connector Pin-out (J2H1)...................................................................................72  
Table 45. External Serial A Port Pin-out (J8A1)..........................................................................73  
Table 46. Internal 9-pin Serial B Header Pin-out (J1B2).............................................................73  
Table 47. Internal USB Connector Pin-out ( J1E1, J1D1)...........................................................74  
Table 48. Pin-out of Internal USB Connector for Floppy ( J1J2).................................................74  
Table 49. Pin-out of Internal USB Connector for low-profile Intel® Z-U130 Value Solid State  
Drive (J3F2)..........................................................................................................................74  
Table 50. Pin-out of adaptive riser slot / PCI Express slot 6.......................................................75  
Table 51. SSI 4-pin Fan Header Pin-out (J6E1, J1J4, J6J2, J7J1, J6B1) ..................................79  
Table 52. Server Board Jumpers (J1F1, J1F2, J1F3, J1F5, J1A2) ............................................80  
Table 53. Front Panel Status LED Behavior Summary...............................................................84  
Table 54. POST Code Diagnostic LED Location ........................................................................85  
Table 55. Server Board Design Specifications ...........................................................................86  
Table 56. Intel® Xeon® Processor TDP Guidelines.....................................................................88  
Table 57. 350-W Load Ratings ...................................................................................................88  
Table 58. Voltage Regulation Limits ...........................................................................................89  
Table 59. Transient Load Requirements.....................................................................................89  
Table 60. Capacitve Loading Conditions ....................................................................................90  
Table 61. Ripple and Noise.........................................................................................................90  
Table 62. Output Voltage Timing ................................................................................................91  
Table 63. Turn On/Off Timing .....................................................................................................92  
Table 64. Over-Current Protection (OCP)...................................................................................93  
Table 65. Over-voltage Protection (OVP) Limits.........................................................................93  
Table 66. Integrated BMC Core Sensors..................................................................................105  
Revision 1.0  
xi  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Tables  
IntelP®P Server Board S3420GP TPS  
Table 67. POST Progress Code LED Example ........................................................................109  
Table 68. Diagnostic LED POST Code Decoder ......................................................................109  
Table 69. POST Error Messages and Handling........................................................................113  
Table 70. POST Error Beep Codes ..........................................................................................117  
xii  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
List of Tables  
<This page intentionally left blank.>  
Revision 1.0  
xiii  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
IntelP®P Server Board S3420GP TPS  
1. Introduction  
This Technical Product Specification (TPS) provides board specific information detailing the  
features, functionality, and high-level architecture of the Intel® Server Board S3420GP.  
In addition, you can obtain design-level information for specific subsystems by ordering the  
External Product Specifications (EPS) or External Design Specifications (EDS) for a given  
subsystem. EPS and EDS documents are not publicly available and must be ordered through  
your local Intel representative.  
1.1 Chapter Outline  
This document is divided into the following chapters:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Chapter 1 – Introduction  
Chapter 2 – Server Board Overview  
Chapter 3 – Functional Architecture  
Chapter 4 – Platform Management  
Chapter 5 – BIOS User Interface  
Chapter 6 – Connector / Header Locations and Pin-outs  
Chapter 7 –Jumpers Blocks  
Chapter 8 – Intel® Light-Guided Diagnostics  
Chapter 9 – Design and Environmental Specifications  
Chapter 10 – Regulatory and Certification Information  
Appendix A – Integration and Usage Tips  
Appendix B – Integrated BMC Sensor Tables  
Appendix C – POST Code Diagnostic LED Decoder  
Appendix D – POST Code Errors  
Appendix E – Supported Intel® Server Chassis  
1.2 Server Board Use Disclaimer  
Intel Corporation server boards contain a number of high-density VLSI and power delivery  
components that need adequate airflow to cool. Intel ensures through its own chassis  
development and testing that when Intel server building blocks are used together, the fully  
integrated system meets the intended thermal requirements of these components. It is the  
responsibility of the system integrator who chooses not to use Intel developed server building  
blocks to consult vendor datasheets and operating parameters to determine the amount of  
airflow required for their specific application and environmental conditions. Intel Corporation  
cannot be held responsible if components fail or the server board does not operate correctly  
when used outside any of their published operating or non-operating limits.  
2
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Overview  
2. Overview  
The Intel® Server Board S3420GP is a monolithic printed circuit board (PCB) with features  
designed to support entry-level severs. It has three board SKUs: S3420GPLX, S3420GPLC,  
and S3420GPV.  
2.1 Intel® Server Board S3420GP Feature Set  
Table 1. Intel® Server Board S3420GP Feature Set  
Feature  
Processor  
Description  
Support for one Xeon® 3400 Series Processor in FC-LGA 1156 socket package.  
ƒ
ƒ
2.5 GT/s point-to-point DMI interface to PCH  
LGA 1156 pin socket  
Memory  
Two memory channels with support for 1066/1333 MHz ECC Unbuffered (UDIMM) or  
ECC Registered (RDIMM) (Intel® Xeon® 3400 Series only) DDR3.  
Intel® Server Board S3420GPLX and S3420GPLC  
ƒ
ƒ
Up to 2 UDIMMs or 3 RDIMM (Intel® Xeon® 3400 Series only) per channel  
32 GB max with x8 ECC RDIMM (2 Gb DRAM) and 16 GB max with x8  
ECC UDIMM (2 Gb DRAM)  
Intel® Server Board S3420GPV  
ƒ
ƒ
Up to 2 UDIMMs per channel  
16 GB max with x8 ECC UDIMM (2 Gb DRAM)  
Intel® Server board S3420GPLX  
Chipset  
ƒ
ƒ
ƒ
Support for Intel® 3420 Chipset Plaftorm Controller Hub (PCH)  
ServerEngines* LLC Pilot II BMC controller (Integrated BMC)  
PCI Express* switch  
Intel® Server board S3420GPLC  
ƒ
ƒ
Support for Intel® 3420 Chipset Platform Controller Hub (PCH)  
ServerEngines* LLC Pilot II BMC controller (Integrated BMC)  
External connections:  
I/O  
ƒ
ƒ
ƒ
DB-15 video connectors  
DB-9 serial Port A connector  
Four ports on two USB/LAN combo connectors at rear of board.  
Internal connections:  
ƒ
ƒ
ƒ
ƒ
ƒ
Two USB 2x5 pin headers, each supporting two USB 2.0 ports  
One 2x5 Serial Port B header  
Six SATA II connectors  
One Intel® SAS Entry RAID Module AXX4SASMOD connector  
One SAS mezzanine slot supports for optional Intel® Remote Management  
Module 3  
Revision 1.0  
1
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
IntelP®P Server Board S3420GP TPS  
Feature  
Description  
Intel® Server Board S3420GPLX  
Add-in PCI Card, PCI  
Express* Card  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Slot1: One 5V PCI 32 bit / 33 MHz connector.  
Slot2: One PCI Express* Gen1 x4 (x1 throughput) connector.  
Slot3: One PCI Express* Gen1 x8 (x4 throughput) connector.  
Slot4: One PCI Express* Gen2 x8 (x4 throughput) connector.  
Slot5: One PCI Express* Gen2 x8 (x8 throughput) connector.  
Slot6: One PCI Express* Gen2 x16 (x8 throughput) connector.  
Intel® Server Board S3420GPLC/ S3420GPV  
ƒ
ƒ
ƒ
ƒ
Slot1: One 5V PCI 32 bit / 33 MHz connector.  
Slot3: One PCI Express* Gen1 x8 (x4 throughput) connector.  
Slot5: One PCI Express* Gen2 x8 (x8 throughput) connector.  
Slot6: One PCI Express* Gen2 x16 (x8 throughput) connector.  
System Fan Support  
Video  
Five 4-pin fan headers supporting four system fans and one processor.  
Onboard ServerEngines* LLC Pilot II BMC Controller  
ƒ
ƒ
Integrated 2D Video Controller  
64-MB DDR2 667 MHz Memory  
Onboard Hard Drive  
Support for six Serial ATA II hard drives through six onboard SATA II connectors with  
SW RAID 0, 1, 5, and 10.  
Intel® Server Board S3420GPLX:  
ƒ
Up to four SAS hard drives through option Intel® SAS Entry RAID Module  
AXX4SASMOD card  
LAN  
One Gigabit Ethernet device 82574L connect to PCI-E x1 interfaces on the PCH.  
Intel® Server Board S3420GPLX/S3420GPLC:  
ƒ
One Gigabit Ethernet PHY 82578DM connected to PCH through PCI-E x1  
interface  
Server Management  
Onboard LLC Pilot II Controller (iBMC)  
ƒ
Integrated Baseboard Management Controller (Integrated BMC), IPMI 2.0  
compliant  
ƒ
Integrated 2D video controller on PCI-E x1  
Intel® Server Board S3420GPLX  
ƒ
Intel® Remote Management Module III (RMM3)  
2
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Overview  
2.2 Server Board Layout  
Figure 1. Intel® Server Board S3420GPLX Picture  
Revision 1.0  
3
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
IntelP®P Server Board S3420GP TPS  
2.2.1  
Server Board Connector and Component Layout  
The following figure shows the board layout of the server board. Each connector and major  
component is identified by a number or letter, and 2 provides the description.  
A
B
C
E
F
G
H
I
J
D
K
L
M
N
O
DD  
CC  
BB  
P
AA  
Z
V
T
S
R
Q
W
U
X
AF003290  
Y
Figure 2. Intel® Server Board S3420GP Layout  
4
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Overview  
Table 2. Major Board Components  
Description  
Slot 1, 32 Mbit/33 MHz PCI  
Description  
System FAN2 and System FAN 3  
CPU connector  
A
B
Q
R
Slot 2, PCI Express* Gen1 x1 (x4 connector)  
(Intel Server Board S3420GPLX only)  
C
D
E
Intel RMM3 Connector(Intel Server Board  
S3420GPLX only)  
S
T
U
CPU Fan connector  
USB SSD connector  
Slot 3, PCI Express* Gen1 x4 (PCI Express*  
Gen2 compliant)  
Slot 4, PCI Express* Gen2 x4 (x8 connector)  
(x8 connector)( Intel® Server Board S3420GPLX  
only)  
SAS Module connector ( Intel® Server Board  
S3420GPLX only)  
F
G
H
I
Slot 5. PCI Express* Gen2 x8 (x8 connector)  
Slot 6, PCI Express* Gen2 x8 (x16 connector)  
CMOS battery  
V
System FAN 1  
IPMB  
W
X
SATA_SGPIO  
HSBP  
Ethernet and Dual USB COMBO  
Ethernet and Dual USB COMBO  
System FAN 4  
Y
J
Z
USB Floppy  
K
L
AA  
BB  
CC  
DD  
Six SATA ports  
Internal USB Connector  
Front Panel Connector  
Internal Serial Port  
Video port  
M
External Serial port  
N
O
P
Main Power Connector  
CPU Power connector  
DIMM slots  
Revision 1.0  
5
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
IntelP®P Server Board S3420GP TPS  
2.2.2  
Intel® Server Board S3420GP Mechanical Drawings  
Figure 3. Intel® Server Board S3420GP – Key Connector and LED Indicator IDENTIFICATION  
6
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Overview  
Figure 4. Intel® Server Board S3420GP – Hole and Component Positions  
Revision 1.0  
7
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
IntelP®P Server Board S3420GP TPS  
Figure 5. Intel® Server Board S3420GP – Major Connector Pin Location (1 of 2)  
8
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Overview  
Figure 6. Intel® Server Board S3420GP –Major Connector Pin Location (2 of 2)  
Revision 1.0  
9
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
IntelP®P Server Board S3420GP TPS  
Figure 7. Intel® Server Board S3420GP – Primary Side Keepout Zone  
10  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Overview  
Figure 8. Intel® Server Board S3420GP – Secondary Side Keepout Zone  
Revision 1.0  
11  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
IntelP®P Server Board S3420GP TPS  
2.2.3  
Server Board Rear I/O Layout  
The following figure shows the layout of the rear I/O components for the server board.  
A
B
Serial Port A  
Video  
C
D
NIC Port 1 (1 Gb) and Dual USB Port  
Connector  
NIC port 2 (1 Gb) and Dual USB Port  
Connector  
Figure 9. Intel® Server Board S3420GP Rear I/O Layout  
12  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Functional Architecture  
3. Functional Architecture  
The architecture and design of the Intel® Server Board S3420GP is based on the Intel® 3420  
Chipset. The chipset is designed for systems based on the Intel® Xeon® processor in the FC-  
LGA 1156 socket package. The chipset contains two main components:  
ƒ
ƒ
Intel® 3420 Chipset  
PCI Express* switch (Intel® Server Board S3420GPLX only).  
This chapter provides a high-level description of the functionality associated with each chipset  
component and the architectural blocks that make up the server board.  
ATX - 12" x 9.6"  
S3420GPLX Block Diagram  
(x16 connector)  
PCIe Gen2 x8  
Slot 6  
4 unbuffered  
or  
6 registered  
DIMMs  
DDR3 (Ch B)  
DDR3 (Ch A)  
Intel® Xeon®  
3400  
(x8 connector)  
(x8 connector)  
Slot 5  
Slot 4  
PCIe Gen2 x8  
IC
PCIe Gen2 x8  
G2PS
PCIe Gen2 x4  
PCIe Gen2 x4  
Ch A  
Ch B  
0
XDP0  
SAS  
x4 DMI Gen1  
82578DM  
GbE  
PHY  
(x8 connector)  
(x4 connector)  
GbE  
GbE  
PCIe  
Gen1  
( PCIe Gen1 x1 )  
Slot 3  
Slot 2  
x4  
x1  
PCIe  
Gen1  
x1  
PCIe  
Gen1  
®
Intel 3420  
PCH  
82574L  
PCIe  
Gen1  
PCI  
PCI32  
Slot 1  
SPI  
BMC Boot  
Flash  
x1  
RMII  
FLASH  
SPI  
FLASH  
DDR2  
SATA-II  
6
12  
IBMC  
SATA  
LPC  
SERIAL 2  
USB  
1.1  
USB  
2.0  
PORT 80  
6 onboard  
USB  
SERIAL 1  
VIDEO  
Notes:  
1. Video integrated into BMC.  
1
1
2
2
SPI  
2
2
RMII  
RMM3  
Z-U130  
(User Bay  
headers)  
USB  
Floppy  
Header  
USB  
USB  
(FP  
headers)  
ejd  
Figure 10. Intel® Server Board S3420GP Functional Block Diagram For S3420GPLX  
Revision 1.0  
13  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Architecture  
IntelP®P Server Board S3420GP TPS  
ATX - 12" x 9.6"  
S3420GPLC Block Diagram  
(x16 connector)  
PCIe Gen2 x8  
Slot 6  
4 unbuffered  
or  
6 registered  
DIMMs  
Intel® Xeon®  
3400  
DDR3 (Ch B)  
DDR3 (Ch A)  
Processor  
(x8 connector)  
PCIe Gen2 x8  
Slot 5  
Ch A  
Ch B  
XDP0  
x4 DMI Gen1  
82578DM  
GbE  
PHY  
(x8 connector)  
GbE  
GbE  
PCIe  
Gen1  
( PCIe Gen1 x1 )  
Slot 3  
x4  
Intel®  
PCIe  
Gen1  
x1  
82574  
3420  
PCIe  
Gen1  
PCI  
PCI32  
Chipset  
Slot 1  
SPI  
BMC Boot  
Flash  
x1  
RMII  
FLASH  
SPI  
FLASH  
DDR2  
SATA-II  
6
12  
IBMC  
SATA  
LPC  
SERIAL 2  
USB  
1.1  
USB  
2.0  
PORT 80  
6 onboard  
USB  
SERIAL 1  
VIDEO  
Notes:  
1. Video integrated into BMC.  
1
1
SPI  
2
2
2
2
RMII  
Z-U130  
(User Bay  
headers)  
USB  
Floppy  
Header  
USB  
USB  
(FP  
headers)  
ejd  
Figure 11. Intel® Server Board S3420GP Functional Block Diagram From S3420GPLC  
<TBD>  
Figure 12. Intel® Server Board S3420GP Functional Block Diagram From S3420GPV  
3.1 Processor Sub-System  
The Intel® Server Board S3420GP supports the following processor:  
ƒ
Intel® Xeon® 3400 Processor series  
The Intel® Xeon® 3400 Series processors processors are made up of multi-core processors  
based on the 45 nm process technology.  
3.1.1  
Intel® Xeon® 3400 Processor  
The Intel® Xeon® 3400 Series processors highly integrated solution variant is composed of four  
Nehalem-based processor cores.  
ƒ
ƒ
FC-LGA 1156 socket package with 2.5 GT/s.  
Up to 95 W Thermal Design Power (TDP); processors with higher TDP are not  
supported.  
14  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Functional Architecture  
The server board does not support previous generations of the Intel® Xeon® processors.  
3.1.2  
Intel® Turbo Boost Technology  
Intel® Turbo Boost Technology is featured on certain processors in the Intel® Xeon® Processor  
3400 Series. Intel® Turbo Boost Technology opportunistically and automatically allows the  
processor to run faster than the marked frequency if the processor is operating below power,  
temperature, and current limits. This results in increased performance for both multi-threaded  
and single-threaded workloads.  
Intel® Turbo Boost Technology operation:  
ƒ
Turbo Boost operates under Operating System control – It is only entered when the  
operating system requests the highest (P0) performance state.  
ƒ
ƒ
Turbo Boost operation can be enabled or disabled by BIOS.  
Turbo Boost converts any available power and thermal headroom into higher frequency  
on active cores. At nominal marked processor frequency, many applications consume  
less than the rated processor power draw.  
ƒ
ƒ
Turbo Boost availability is independent of the number of active cores.  
Maximum Turbo Boost frequency depends on the number of active cores and varies by  
processor configuration.  
ƒ
The amount of time the system spends in Turbo Boost operation depends on workload,  
operating environment, and platform design.  
If the processor supports the Intel® Turbo Boost Technology feature, the BIOS Setup provides  
an option to enable or disable this feature. The default state is enabled.  
3.1.3  
Simultaneous Multithreading (SMT)  
Most Intel® Xeon® processors support Simultaneous Multithreading (SMT). The BIOS detects  
processors that support this feature and enables the feature during POST.  
If the processor supports this feature, the BIOS Setup provides an option to enable or disable  
this feature. The default is enabled.  
3.1.4  
Enhanced Intel SpeedStep® Technology  
Intel® Xeon® processors support the Geyserville3 feature of the Enhanced Intel SpeedStep®  
technology. This feature changes the processor operating ratio and voltage similar to the  
Thermal Monitor 1 (TM1) feature. The BIOS implements the Geyserville3 feature in conjunction  
with the TM1 feature. The BIOS enables a combination of TM1 and TM2 according to the  
processor BIOS writer's guide.  
3.2 Memory Subsystem  
The Intel® Xeon® 3400 series processor has an Integrated Memory Controller (IMC) in its  
package. Each Intel® Xeon® 3400 series processor produces up to two DDR3 channels of  
memory. Each DDR3 channel in the IMC supports up to three DDR3 RDIMM slots or up to two  
UDIMM slots. The DDR3 RDIMM frequency can be 800/1066/1333 MHz. DDR3 UDIMM  
Revision 1.0  
15  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Architecture  
IntelP®P Server Board S3420GP TPS  
frequency can be 1066/1333 MHz. All RDIMMs and UDIMMs include ECC (Error Correction  
Code) operation. Various speeds and memory technologies are supported.  
RAS (Reliability, Availability, and Serviceability) is not supported on the Intel® Server Board  
S3420GP.  
3.2.1  
Memory Sizing and Configuration  
The Intel® Server Board S3420GP supports various memory module sizes and configurations.  
These combinations of sizes and configurations are valid only for DDR3 DIMMs approved by  
Intel Corporation.  
S3420GP BIOS supports:  
z
z
z
z
z
DIMM sizes of 1 GB, 2 GB, 4 GB, and 8 GB.  
DIMMs composed of DRAM using 2 Gb technology.  
DRAMs organized as single rank, dual rank, or quad rank DIMMS.  
DIMM speeds of 800, 1066, or 1333 MT/s.  
Registered or Unregistered (unbuffered) DIMMs (RDIMMs or UDIMMs).  
Note: UDIMMs should be ECC, and may or may not have thermal sensors; RDIMMs must have  
ECC and must have thermal sensors.  
S3420GP BIOS has the below limitations:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
256 Mb technology, x4 DRAM on UDIMM, and quad rank UDIMM are NOT supported  
x16 DRAM on UDIMM is not supported on combo routing  
Memory suppliers not productizing native 800 ECC UDIMMs  
Intel® Xeon® 3400 Series support all timings defined by JEDEC.  
256 Mb/512 Mb technology, x4 and x16 DRAMs on RDIMM are NOT supported  
All channels in a system will run at the fastest common frequency  
No mixing of registered and unbuffered DIMMs  
3.2.2  
Post Error Codes  
The range {0xE0 - 0xEF} of POST codes is used for memory errors in early POST. In late POST,  
this range is used for reporting other system errors.  
z
0xE8 - No Usable Memory Error: If no memory is available, the system emits POST  
Diagnostic LED code 0xE8 and halts the system.  
z
0xE8 - Configuration Error: If a DDR3 DIMM has no SPD information, the BIOS treats  
the DIMM slot as if no DDR3 DIMM is present on it. Therefore, if this is the only DDR3  
DIMM installed in the system, the BIOS halts with POST Diagnostic LED code 0xE8 (no  
usable memory) and halts the system.  
z
0xEB - Memory Test Error: If a DDR3 DIMM or a set of DDR3 DIMMs on the same  
memory channel (row) fails HW Memory BIST but usable memory remains available,  
the BIOS emits a beep code and displays POST Diagnostic LED code 0xEB  
momentarily during the beeping and then continues POST. If all of the memory fails HW  
16  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Functional Architecture  
Memory BIST, the system acts as if no memory is available, beeping and halting with  
the POST Diagnostic LED code 0xE8 (No Usable Memory) displayed.  
z
0xEA - Channel Training Error: If the memory initialization process is unable to  
properly perform the DQ/DQS training on a memory channel, the BIOS emits a beep  
code and displays POST Diagnostic LED code 0xEA momentarily during the beeping. If  
there is usable memory in the system on other channels, POST memory initialization  
continues. Otherwise, the system halts with POST Diagnostic LED code 0xEA staying  
displayed.  
z
z
0xED - Population Error: If the installed memory contains a mix of RDIMMs and  
UDIMMs, the system halts with POST Diagnostic LED code 0xED.  
0xEE - Mismatch Error: If more than two quad-ranked DIMMs are installed on any  
channel in the system, the system halts with POST Diagnostic LED code 0xEE.  
3.2.3  
Publishing System Memory  
The BIOS displays the Total Memory of the system during POST if Quiet Boot is  
disabled in the BIOS setup. This is the total size of memory discovered by the BIOS  
during POST, and is the sum of the individual sizes of installed DDR3 DIMMs in the  
system.  
The BIOS displays the Effective Memory of the system in the BIOS Setup. The term  
Effective Memory refers to the total size of all active DDR3 DIMMs (not disabled) and not  
used as redundant units.  
The BIOS provides the total memory of the system in the main page of the BIOS setup.  
This total is the same as the amount described by the first bullet in this section.  
If Quiet Boot is disabled, the BIOS displays the total system memory on the diagnostic  
screen at the end of POST. This total is the same as the amount described by the first  
bullet in this section.  
The BIOS provides the total amount of memory in the system.  
3.2.3.1  
Memory Reservation for Memory-mapped Functions  
A region of size 40 MB of memory below 4 GB is always reserved for mapping chipset,  
processor, and BIOS (flash) spaces as memory-mapped I/O regions. This region appears as a  
loss of memory to the operating system. In addition to this loss, the BIOS creates another  
reserved region for memory-mapped PCIe functions, including a standard 64 MB or 256 MB of  
standard PCI Express* MMIO configuration space.  
If PAE is turned on in the operating system, the operating system reclaims all these reserved  
regions.  
In addition to this memory reservation, the BIOS creates another reserved region for memory-  
mapped PCI Express* functions, including a standard 64 MB or 256 MB of standard PCI  
Express* Memory Mapped I/O (MMIO) configuration space. This is based on the selection of  
Maximize Memory below 4 GB in the BIOS Setup.  
If this is set to Enabled, the BIOS maximizes usage of memory below 4 GB for an operating  
system without PAE capability by limiting PCI Express* Extended Configuration Space to 64  
buses rather than the standard 256 buses. This is done using the MAX_BUS_NUMBER feature  
Revision 1.0  
17  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Architecture  
IntelP®P Server Board S3420GP TPS  
offered by the Intel® S3420 I/O Hub and a variably-sized Memory Mapped I/O region for the PCI  
Express* functions.  
3.2.3.2  
High-Memory Reclaim  
When 4 GB or more of physical memory is installed (physical memory is the memory installed  
as DDR3 DIMMs), the reserved memory is lost. However, the Intel® 3420 chipset provides a  
feature called high-memory reclaim, which allows the BIOS and operating system to remap the  
lost physical memory into system memory above 4 GB (the system memory is the memory the  
processor can see).  
The BIOS always enables high-memory reclaim if it discovers installed physical memory equal  
to or greater than 4 GB. For the operating system, the reclaimed memory is recoverable only if  
the PAE feature in the processor is supported and enabled. Most operating systems support  
this feature. For details, see the relevant operating system manuals.  
3.2.3.3  
ECC Support  
Only ECC memory is supported on this platform.  
3.2.4  
Support for Mixed-speed Memory Modules  
The BIOS supports memory modules of mixed speed by automatic selection of the lowest  
common frequency of all memory modules (DDR3 DIMM). Each DDR3 DIMM advertises its  
lowest supported clock speed through the TCKMIN parameter in its Serial-presence Data (SPD).  
The BIOS uses this information to arrive at the common lowest frequency that satisfies all  
installed DDR3 DIMMs.  
This section describes the expected outcome on the installation of DDR3 DIMMs of different  
frequencies in the system for a given user-selected frequency. The following rules apply:  
ƒ
ƒ
ƒ
ƒ
If all three single-rank/dual-rank RDIMM slots are populated on a channel, the BIOS  
forces a global common frequency of 800 MHz.  
If two quad-rank RDIMM are populated on one channel, the BIOS forces a global  
common frequency of 800 MHz.  
If one quad-rank RDIMM are populated on one channel, the BIOS forces a global  
common frequency of 1066 MHz.  
If a maximum of only two DIMM slots are populated in the system among all channels  
and one or more DIMMs support DDR3 frequency greater than 1333 MHz, the BIOS  
forces a global common frequency of 1333 MHz.  
3.2.5  
Memory Map and Population Rules  
The following nomenclature is followed for DIMM sockets:  
Note: Intel® Server Board S3420GP may support up to three DIMM sockets per channel.  
Table 3. Standard Platform DIMM Nomenclature  
Channel A  
Channel B  
A1  
A2  
A3  
B1  
B2  
B3  
18  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Functional Architecture  
3.2.5.1  
TableMemory Subsystem Operating Frequency Determination  
The rules for determining the operating frequency of the memory channels are simple, but not  
necessarily straightforward. There are several limiting factors, including the number of DIMMs  
on a channel and organization of the DIMM - that is, either single-rank (SR), dual-rank (DR), or  
quad-rank (QR):  
ƒ
ƒ
The speed of the processor’s IMC is the maximum speed possible.  
The speed of the slowest component – the slowest DIMM or the IMC – determines the  
maximum frequency, subject to further limitations.  
ƒ
ƒ
ƒ
ƒ
A single 1333-MHz DIMM (SR or DR) on a channel may run at full 1333-MHz speed.  
If two SR/DR DIMMs are installed on a channel, the speed is limited to 1066 MHZ.  
A single QR RDIMM on a channel is limited to 1066 MHz.  
Two QR RDIMMs or a mix of QR + SR/DR on a channel is limited to 800 MHz.  
3.2.5.2  
Memory Subsystem Nomenclature  
1. DIMMs are organized into physical slots on DDR3 memory channels that belong to  
processor sockets.  
2. The memory channels are identified as channels A, B.  
3. For Intel® Xeon® 3400 Series, each socket can support a maximum of six DIMM  
sockets (three DIMM sockets per channel), which can support a maximum of six  
DIMM sockets.  
4. The Intel® Xeon® 3400 Series processor on the Intel® Server Board S3420GP is  
populated on the processor socket. It has an Integrated Memory Controller (IMC).  
The IMC provides two DDR3 channels and groups DIMMs on the board into an  
autonomous memory.  
5. The DIMM identifiers on the silkscreen on the board provide information about the  
channel and the processor socket to which they belong. For example, DIMM_A1 is  
the first slot on channel A.  
3.2.5.3  
Memory Upgrade Rules  
Upgrading the system memory requires careful positioning of the DDR3 DIMMs based on the  
following factors:  
ƒ
ƒ
ƒ
Existing DDR3 DIMM population  
DDR3 DIMM characteristics  
Optimization techniques used by the Intel® Nehalem processor to maximize memory  
bandwidth  
In the Independent Channel mode, all DDR3 channels operate independently. Slot-to-slot DIMM  
matching is not required across channels (for example, A1 and B1 do not have to match each  
other in terms of size, organization, and timing). DIMMs within a channel do not have to match  
in terms of size and organization, but they operate in the minimal common frequency. Also,  
Independent Channel mode can be used to support single DIMM configuration in channel A and  
in the Single Channel mode.  
Revision 1.0  
19  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Architecture  
IntelP®P Server Board S3420GP TPS  
Channel A  
Channel B  
B2  
A1  
A2  
A3  
B1  
B3  
RDIMM  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
UDIMM  
X
X
X
X
X
X
X
You must observe the following general rules when selecting and configuring memory to obtain  
the best performance from the system.  
1. DDR3 RDIMMs must always be populated using a fill-farthest method.  
2. DDR3 UDIMMs must always be populated on DIMM A1/A2/B1/B2.  
3. Intel® Xeon® 3400 Series Processors support either RDIMMs or UDIMMs.  
4. RDIMM and UDIMM CANNOT be mixed.  
5. The minimal memory set is {DIMMA1}.  
6. DDR3 DIMMs on adjacent slots on the same channel do not need to be identical.  
Each socket supports a maximum of six slots. Standard Intel® server boards and systems that  
use the Intel® 3420 chipset support three slots per DDR3 channel, two DDR3 channels per  
socket, and only one socket is supported on the Intel® Server Board S3420GP.  
3.2.5.4  
Memory Configuration Table  
Table 4. Memory Configuration Table  
This table defines half of the valid memory configurations. You can exchange Channel A DIMMs  
with the DIMMs on Channel B to get another half.  
20  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Functional Architecture  
3.3 Intel® 3420 Chipset PCH  
The Intel® 3420 Chipset component is the Platform Controller Hub (PCH). The PCH is designed  
for use with Intel® processor in a UP server platform. The role of the PCH in Intel® Server Board  
S3420GP is to manage the flow of information between its eleven interfaces:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
DMI interface to Processor  
PCI Express* Interface  
PCI Interface  
SATA Interface  
USB Host Interface  
SMBus Host Interface  
SPI Interface  
LPC interface to IBMC  
JTAG interface  
LAN interface  
ACPI interface  
3.4 I/O Sub-system  
Intel® 3420 Chipset PCH provides extensive I/O support.  
3.4.1  
PCI Express Interface  
Two different PCI-E configurations on single board are dependent on different board SKUs:  
z
Intel® Server Board S3420GPLX  
One PCI-E X16 slot connected to the PCI-E ports of CPU. Two PCI-E x8 slots and one SAS  
module connected to PCI-E ports of PCIe switch. One PCI-E X8 slot and one PCI-E x4 slot  
connected to the PCI-E ports of PCH.  
z
z
Intel® Server Board S3420GPLC  
One PCI-E X16 slot and one PCI-E X8 slot connected to the PCI-E ports of CPU. One PCI-  
E x8 slot connected to the PCI-E ports of PCH.  
Intel® Server Board S3420GPV  
<TBD>  
There is one 32-bit, 33-MHz 5-V PCI slot.  
Compatibility with the PCI addressing model is maintained to ensure all existing applications  
and drivers operate unchanged.  
The PCI Express* configuration uses standard mechanisms as defined in the PCI Plug-and-  
Play specification. The initial recovered clock speed of 1.25 GHz results in 2.5 Gb/s/direction,  
which provides a 250-MB/s communications channel in each direction (500 MB/s total). This is  
close to twice the data rate of classic PCI. The fact that 8b/10b encoding is used accounts for  
the 250 MB/s where quick calculations would imply 300 MB/s. The external graphics ports  
support 5.0 GT/s speed as well. Operating at 5.0 GT/s results in twice as much bandwidth per  
lane as compared to 2.5 GT/s operation.  
Revision 1.0  
21  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Architecture  
IntelP®P Server Board S3420GP TPS  
When operating with two PCI Express* controllers, each controller can operate at either 2.5  
GT/s or 5.0 GT/s. The PCI Express* architecture is specified in three layers: Transaction Layer,  
Data Link Layer, and Physical Layer. The partitioning in the component is not necessarily along  
these same boundaries.  
3.4.2  
Serial ATA Support  
The Intel® 3420 Chipset has two integrated SATA host controllers that support independent  
DMA operation on up to six ports and supports data transfer rates of up to 3.0 GB/s (300 MB/s).  
The SATA controller contains two modes of operation – a legacy mode using I/O space and an  
AHCI mode using memory space.  
Software that uses legacy mode does not have AHCI capabilities. The Intel® 3420 Chipset  
supports the Serial ATA Specification, Revision 1.0a. The Ibex Peak also supports several  
optional sections of the Serial ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0  
(AHCI support is required for some elements).  
3.4.2.1 Intel® Matrix Storage Technology  
The Intel® 3420 Chipset provides support for Intel® Matrix Storage Technology, providing both  
AHCI (see above for details on AHCI) and integrated RAID functionality. The industry leading  
RAID capability provides high-performance RAID 0, 1, 5, and 10 functionality on up to six SATA  
ports of PCH. Matrix RAID support is provided to allow multiple RAID levels to be combined on  
a single set of hard drives, such as RAID 0 and RAID 1 on two disks. Other RAID features  
include hot spare support, SMART alerting, and RAID 0 autos replace. Software components  
include an Option ROM for pre-boot configuration and boot functionality, a Microsoft Windows*  
compatible driver, and a user interface to configure and manage the RAID capability of the  
Intel® 3420 Chipset.  
3.4.3  
USB 2.0 Support  
On the Intel® 3420 Chipset, the USB controller functionality is provided by the dual EHCI  
controllers with an interface for up to ten USB 2.0 ports. All ports are high-speed, full-speed,  
and low-speed capable.  
ƒ
ƒ
Four external connectors are located on the back edge of the server board.  
Two internal 2x5 header (J1E2 and J1D1) are provided, each supporting two optional  
USB 2.0 ports.  
ƒ
ƒ
One port on internal vertical connector to support NIC.  
One port on 1x4pin (J1J2) on-board header to support floppy.  
3.4.3.1 Native USB Support  
During the power-on self test (POST), the BIOS initializes and configures the USB subsystem.  
The BIOS is capable of initializing and using the following types of USB devices.  
ƒ
ƒ
ƒ
USB Specification-compliant keyboards  
USB Specification-compliant mouse  
USB Specification-compliant storage devices that utilize bulk-only transport mechanism  
USB devices are scanned to determine if they are required for booting.  
22  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Functional Architecture  
The BIOS supports USB 2.0 mode of operation, and as such supports USB 1.1 and USB 2.0  
compliant devices and host controllers.  
During the pre-boot phase, the BIOS automatically supports the hot addition and hot removal of  
USB devices and a short beep is emitted to indicate such an action. For example, if a USB  
device is hot plugged, the BIOS detects the device insertion, initializes the device, and makes it  
available to the user. During POST, when the USB controller is initialized, it emits a short beep  
for each USB device plugged into the system as they were all just “hot added”.  
Only on-board USB controllers are initialized by BIOS. This does not prevent the operating  
system from supporting any available USB controllers including add-in cards.  
3.4.3.2 Legacy USB Support  
The BIOS supports PS/2 emulation of USB keyboards and mouse. During POST, the BIOS  
initializes and configures the root hub ports and searches for a keyboard and/or a mouse on the  
USB hub and then enables the devices that are recognized.  
3.5 Optional Intel® SAS Entry RAID Module AXX4SASMOD  
The Intel® Server Board S3420GPLX provides a SAS Mezzanine slot (J2H1) for the installation  
of an optional Intel® SAS Entry RAID Module AXX4SASMOD. Once the optional Intel® SAS  
Entry RAID Module AXX4SASMOD is detected, the x4 PCI Express* links from the PCI  
switches to the SAS Mezzanine slot. The optional Intel® SAS Entry RAID Module  
AXX4SASMOD includes a SAS1064e controller that supports x4 PCI Express* link widths and  
is a single-function PCI Express* end-point device.  
The SAS controller supports the SAS protocol as described in the Serial Attached SCSI  
Standard, version 1.0, and also supports SAS 1.1 features. A 32-bit external memory bus off the  
SAS1064e controller provides an interface for Flash ROM and NVSRAM (Non-volatile Static  
Random Access Memory) devices.  
The optional Intel® SAS Entry RAID Module AXX4SASMOD provides four SAS connectors that  
support up to four hard drives with a non-expander backplane or up to eight hard drives with an  
expander backplane.  
3.6 Integrated Baseboard Management Controller  
The ServerEngines* LLC Pilot II Integrated BMC is provided by an embedded ARM9 controller  
and associated peripheral functionality that is required for IPMI-based server management.  
Firmware usage of these hardware features is platform-dependant.  
The following is a summary of the Integrated BMC management hardware features used by the  
ServerEngines* LLC Pilot II Integrated BMC:  
ƒ
ƒ
ƒ
ƒ
ƒ
250 MHz 32-bit ARM9 Processor  
Memory Management Unit (MMU)  
Two 10/100 Ethernet Controllers with NC-SI support  
16-bit DDR2 667 MHz interface  
Dedicated RTC  
Revision 1.0  
23  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Architecture  
IntelP®P Server Board S3420GP TPS  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
12 10-bit ADCs  
Eight Fan Tachometers  
Four PWMs  
Battery-backed Chassis Intrusion I/O Register  
JTAG Master  
Six I2C interfaces  
General-purpose I/O Ports (16 direct, 64 serial)  
Additionally, the ServerEngines* Pilot II part integrates a super I/O module with the following  
features:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
KCS/BT Interface  
Two 16C550 Serial Ports  
Serial IRQ Support  
12 GPIO Ports (shared with BMC)  
LPC to SPI Bridge  
SMI and PME Support  
The Pilot II contains an integrated KVMS subsystem and graphics controller with the following  
features:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
USB 2.0 for keyboard, mouse, and storage devices  
USB 1.1 interface for legacy PS/2 to USB bridging  
Hardware Video Compression for text and graphics  
Hardware encryption  
2D Graphics Acceleration  
DDR2 graphics memory interface  
Up to 1600x1200 pixel resolution  
PCI Express* x1 support  
24  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Integrated BMC Block Diagram  
Functional Architecture  
USB  
to Host  
Code  
Memory  
USB 1.1  
&
USB 2.0  
LPC Master,  
JTAG  
Interrupt  
Controller  
Fan Tach (12)  
PWM (4)  
ADC  
Thermal  
JTAG Master,  
Master  
& SPI FLash  
ARM926EJ-S  
16K D & I  
Cache  
RTC &  
General Purpose  
TImers (3)  
Ethernet  
MAC with  
RMII (2)  
UART  
(3)  
I2C  
(6)  
Crypto  
Accelerator  
DDR-II  
DDR-II  
16-bit  
(up to  
Memory  
667MHz)  
Controller  
BMC & KVMS Subsystem  
KCS  
BT &  
Mailboxes  
System  
Wakeup  
Control  
UART (3)  
GPIO  
Video  
Output  
LPC  
Interface  
To Host  
LPC  
Interface  
Graphics  
Controller  
Real Time Clock  
Interface  
(external RTC)  
PCIe x1  
Interface  
LPC to SPI  
Flash Bridge  
Watchdog  
Timer  
BMC & KVMS Subsystem  
Graphics Subsystem  
Figure 13. Integrated BMC Hardware  
3.6.1  
Integrated BMC Embedded LAN Channel  
The Integrated BMC hardware includes two dedicated 10/100 network interfaces.  
Interface 1: This interface is available from either of the available NIC ports in system that can  
be shared with the host. Only one NIC may be enabled for management traffic at any time. To  
change the NIC enabled for management traffic, please use the “Write LAN Channel Port” OEM  
IPMI command. The default active interface is port 1 (NIC1).  
Interface 2: This interface is available from the optional RMM3 which is a dedicated  
management NIC that is not shared with the host.  
For these channels, support can be enabled for IPMI-over-LAN and DHCP.  
For security reasons, embedded LAN channels have the following default settings:  
ƒ IP Address: Static  
ƒ All users disabled  
3.6.2  
Optional RMM3 Advanced Management Board  
On the Intel® Server Board S3420GPLX provides RMM3 module. RMM3 advanced  
management board serves two purposes:  
Revision 1.0  
25  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Architecture  
IntelP®P Server Board S3420GP TPS  
Give the customer the option to add a dedicated management 100 Mbit LAN interface to  
the product.  
Provide additional flash space, enabling the Advanced Management functions to support  
WS-MAN and CIMON.  
Table 5. Optional RMM3 Advanced Management Board Features  
Feature  
Description  
Remote console access via keyboard, video, and mouse redirection over LAN.  
Remote USB media access over LAN.  
KVM Redirection  
USB Media Redirection  
WS-MAN  
Full SMASH profiles for WS-MAN based consoles.  
3.6.3  
Serial Ports  
The server board provides two serial ports: an external DB9 serial port connector and an  
internal DH-10 serial header.  
The rear DB9 serial A port is a fully-functional serial port that can support any standard serial  
device.  
The Serial B port is an optional port accessed through a 9-pin internal DH-10 header (J1B1).  
You can use a standard DH-10 to DB9 cable to direct serial A port to the rear of a chassis. The  
serial B interface follows the standard RS-232 pin-out as defined in the following table.  
Table 6. Serial B Header (J1B1) Pin-out  
Pin  
Signal Name  
Serial Port B Header Pin-out  
1
DCD  
2
3
4
5
6
7
8
9
DSR  
RX  
RTS  
TX  
CTS  
DTR  
RI  
GND  
3.6.4  
Floppy Disk Controller  
The server board does not support a floppy disk controller interface. However, the system BIOS  
recognizes USB floppy devices.  
3.6.5  
Keyboard and Mouse Support  
The server board does not support PS/2 interface keyboards and mouse. However, the system  
BIOS recognizes USB specification-compliant keyboard and mouse.  
26  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Functional Architecture  
3.6.6  
Wake-up Control  
The super I/O contains functionality that allows various events to power on and power off the  
system.  
3.7 Video Support  
The server board includes a video controller in an on-board Server Engines* Integrated  
Baseboard Management Controller along with 64 MB of video DDR2 SDRAM. The SVGA  
subsystem supports a variety of modes, up to 1600 x 1200 resolution in 8 / 16 / 32 bpp modes  
under 2D. It also supports both CRT and LCD monitors up to a 100 Hz vertical refresh rate.  
The video is accessed using a standard 15-pin VGA connector found on the back edge of the  
server board. The on-board video controller can be disabled using the BIOS Setup utility or  
when an add-in video card is detected. The system BIOS provides the option for dual-video  
operation when an add-in video card is configured in the system.  
3.7.1  
Video Modes  
The integrated video controller supports all standard IBM VGA modes. The following table  
shows the 2D modes supported for both CRT and LCD.  
Table 7. Video Modes  
2D Mode  
Refresh Rate (Hz)  
2D Video Mode Support  
8 bpp  
16 bpp  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
32 bpp  
640x480  
60, 72, 75, 85, 90, 100, 120, 160, 200 Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
800x600  
60, 70, 72, 75, 85, 90, 100, 120,160  
60, 70, 72, 75,85,90,100  
43,47,60,70,75,80,85  
60,70,74,75  
Supported  
Supported  
Supported  
Supported  
Supported  
1024x768  
1152x864  
1280x1024  
1600x1200  
52  
3.7.2  
Dual Video  
The BIOS supports both single-video and dual-video modes. The dual-video mode is disabled  
by default.  
ƒ
ƒ
ƒ
In the single mode (dual monitor video = disabled), the on-board video controller is  
disabled when an add-in video card is detected.  
In single mode, the onboard video controller is disabled when an add-in video card is  
detected.  
In dual mode, the onboard video controller is enabled and is the primary video device.  
The external video card is allocated resources and is considered the secondary video  
device.  
ƒ
When KVM is enabled in iBMC FW, dual video is enabled.  
Table 8. Dual Video Modes  
Revision 1.0  
27  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Architecture  
IntelP®P Server Board S3420GP TPS  
Enabled  
Disabled  
Onboard video controller.  
Warning: System video is completely disabled if  
this option is disabled and an add-in video  
adapter is not installed.  
Onboard Video  
Enabled  
Disabled  
If enabled, both the onboard video controller and  
an add-in video adapter are enabled for system  
video. The onboard video controller becomes  
the primary video device.  
Dual Monitor Video  
3.8 Network Interface Controller (NIC)  
The Intel® Server Board S3420GPLX and S3420GPLC support two network interfaces, One is  
provided from the onboard Intel® 82574L GbE PCI Express network controller; the other is the  
onboard Intel® 82578 Gigabit Network controller.  
The Intel® Server Board S3420GPV only supports one network interface, which is provided from  
the onboard Intel® 82574L GbE PCI Express* network controller.  
3.8.1  
GigE Controller 82574L  
The 82574 family (82574L and 82574IT) are single, compact, low-power components that offer  
a fully-integrated Gigabit Ethernet Media Access Control (MAC) and Physical Layer (PHY) port.  
The 82574 uses the PCI Express* architecture and provides a single-port implementation in a  
relatively small area so it can be used for server and client configurations as a LAN on  
Motherboard (LOM) design.  
External interfaces provided on the 82574:  
PCIe Rev. 2.0 (2.5 GHz) x1  
MDI (Copper) standard IEEE 802.3 Ethernet interface for 1000BASE-T, 100BASETX,  
and 10BASE-T applications (802.3, 802.3u, and 802.3ab)  
NC-SI or SMBus connection to a Manageability Controller (MC)  
EEE 1149.1 JTAG (note that BSDL testing is NOT supported)  
3.8.2  
GigE PHY 82578DM  
The 82578 is a single port Gigabit Ethernet Physical Layer Transceiver (PHY). It connects to the  
Media Access Controller (MAC) through a dedicated interconnect. The 82578DM supports  
operation at 1000/100/10 Mb/s data rates. The PHY circuitry provides a standard IEEE 802.3  
Ethernet interface for 1000BASE-T, 100BASE-TX, and 10BASE-T applications (802.3, 802.3u,  
and 802.3ab).  
The 82578 operates with the Platform Controller Hub (PCH) chipset that incorporates the MAC.  
The 82578 interfaces with its MAC through two interfaces: PCIe-based and SMBus. The PCIe  
(main) interface is used for all link speeds when the system is in an active state (S0) while the  
SMBus is used only when the system is in a low power state (Sx). In SMBus mode, the link  
speed is reduced to 10 Mb/s. The PCIe interface incorporates two aspects: a PCIe SerDes  
(electrically) and a custom logic protocol.  
3.8.3  
MAC Address Definition  
Each Intel® Server Board S3420GPLX has the following four MAC addresses assigned to it at  
the Intel factory:  
ƒ
NIC 1 MAC address  
28  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Functional Architecture  
ƒ
ƒ
ƒ
NIC 2 MAC address – Assigned the NIC 1 MAC address +1  
Integrated BMC LAN Channel MAC address – Assigned the NIC 1 MAC address +2  
Intel® Remote Management Module 3 (Intel® RMM3) MAC address – Assigned the NIC 1  
MAC address +3  
Each Intel® Server Board S3420GPLC has the following three MAC addresses assigned to it at  
the Intel factory:  
ƒ
ƒ
ƒ
NIC 1 MAC address  
NIC 2 MAC address – Assigned the NIC 1 MAC address +1  
Integrated BMC LAN Channel MAC address – Assigned the NIC 1 MAC address +2  
Each Intel® Server Board S3420GPV has the following two MAC addresses assigned to it at the  
Intel® factory:  
<TBD>  
3.9 Intel® I/O Acceleration Technolgy 2 (Intel® I/OAT2)  
The Intel® 3420 chipset series platforms do not support Intel® I/O Acceleration Technology.  
3.9.1  
Direct Cache Access (DCA)  
Direct Cache Access (DCA) is not supported on Intel® Xeon® 3400 Series processors.  
3.10 Intel® Virtualization Technology for Directed I/O (Intel® VT-d)  
The Intel® 3420 chipset provides hardware support for implementation of Intel® Virtualization  
Technology with Directed I/O (Intel® VT-d). Intel VT-d Technology consists of technology  
components that support the virtualization of platforms based on Intel® Architecture Processor.  
Intel VT-d Technology enables multiple operating systems and applications to run in dependent  
partitions. A partition behaves like a virtual machine (VM) and provides isolation and protection  
across partitions. Each partition is allocated its own subset of host physical memory.  
The Intel® Virtualization Technology is designed to support multiple software environments  
sharing the same hardware resources. The Intel® Virtualization Technology can be enabled or  
disabled in the BIOS setup. The default behavior is disabled.  
Note: If the setup options are changed to enable or disable the Virtualization Technology setting  
in the processor, the user must perform an AC power cycle for the changes to take effect.  
Revision 1.0  
29  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Platform Management  
IntelP®P Server Board S3420GP TPS  
4. Platform Management  
The platform management subsystem is based on the Integrated BMC features of the  
ServerEngines* Pilot II. The onboard platform management subsystem consists of  
communication buses, sensors, system BIOS, and server management firmware. The following  
diagram provides an overview of the Server Management Bus (SMBUS) architecture used on  
this server board.  
Figure 14. Server Management Bus (SMBUS) Block Diagram  
4.1Feature Support  
4.1.1  
IPMI 2.0 Features  
ƒ
ƒ
ƒ
ƒ
ƒ
Integrated Baseboard Management Controller (Integrated BMC).  
IPMI Watchdog timer.  
Messaging support, including command bridging and user/session support.  
Chassis device functionality, including power/reset control and BIOS boot flags support.  
Event receiver device: The Integrated BMC receives and processes events from other  
platform subsystems.  
ƒ
Field replaceable unit (FRU) inventory device functionality: The Integrated BMC supports  
access to system FRU devices using IPMI FRU commands.  
30  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Platform Management  
ƒ
ƒ
ƒ
ƒ
System event log (SEL) device functionality: The Integrated BMC supports and provides  
access to a SEL.  
Sensor device record (SDR) repository device functionality: The Integrated BMC  
supports storage and access of system SDRs.  
Sensor device and sensor scanning/monitoring: The Integrated BMC provides IPMI  
management of sensors. It polls sensors to monitor and report system health.  
IPMI interfaces.  
o Host interfaces include system management software (SMS) with receive  
message queue support and server management mode (SMM).  
o Terminal mode serial interface  
o IPMB interface  
o LAN interface that supports the IPMI-over-LAN protocol (RMCP, RMCP+)  
Serial-over-LAN (SOL)  
ƒ
ƒ
ACPI state synchronization: The Integrated BMC tracks ACPI state changes provided by  
the BIOS.  
ƒ
Integrated Baseboard Management Controller (Integrated BMC) self test: The Integrated  
BMC performs initialization and run-time self tests, and makes results available to  
external entities.  
For more information, refer to the IPMI 2.0 Specification.  
4.1.2  
Non-IPMI Features  
The Integrated BMC supports the following non-IPMI features. This list does not preclude  
support for future enhancements or additions.  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
In-circuit Integrated BMC firmware update.  
Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality  
Chassis intrusion detection and chassis intrusion cable presence detection.  
Basic fan control using TControl version 2 SDRs.  
Acoustic management: Support for multiple fan profiles.  
Signal testing support: The Integrated Baseboard Management Controller (Integrated  
BMC) provides test commands for setting and getting platform signal states.  
ƒ
The Integrated Baseboard Management Controller (Integrated BMC) generates  
diagnostic beep codes for fault conditions.  
ƒ
ƒ
System GUID storage and retrieval.  
Front panel management: The Integrated Baseboard Management Controller (Integrated  
BMC) controls the system status LED and chassis ID LED. It supports secure lockout of  
certain front panel functionality and monitors button presses. The chassis ID LED is  
turned on using a front panel button or a command.  
ƒ
ƒ
ƒ
Power state retention  
Power fault analysis  
Intel® Light-Guided Diagnostics  
Revision 1.0  
31  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Platform Management  
IntelP®P Server Board S3420GP TPS  
ƒ
ƒ
ƒ
ƒ
Power unit management: Support for power unit sensor. The Integrated Baseboard  
Management Controller (Integrated BMC) handles power-good dropout conditions.  
DIMM temperature monitoring: New sensors and improved acoustic management using  
closed-loop fan control algorithm taking into account DIMM temperature readings.  
Address Resolution Protocol (ARP): The Integrated BMC sends and responds to ARPs  
(supported on embedded NICs)  
Dynamic Host Configuration Protocol (DHCP): The Integrated BMC performs DHCP  
(supported on embedded NICs).  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Platform environment control interface (PECI) thermal management support.  
E-mail alerting  
Embedded web server  
Integrated KVM  
Integrated Remote Media Redirection  
Lightweight Directory Authentication Protocol (LDAP) support  
4.2 Optional Advanced Management Feature Support  
This section explains the advanced management features supported by the Integrated  
Baseboard Management Controller (Integrated BMC) firmware.  
4.2.1  
Enabling Advanced Management Features  
The Integrated BMC enables the advanced management features only when it detects the  
presence of the Intel® Remote Management Module 3 (Intel® RMM3) card. Without the Intel®  
RMM3, the advanced features are dormant. Only the Intel® Server Board S3420GPLX has a  
RMM3 module interface.  
4.2.1.1  
Intel® RMM3  
The Intel® RMM3 provides the Integrated BMC with an additional dedicated network interface.  
The dedicated interface consumes its own LAN channel. Additionally, the Intel® RMM3 provides  
additional flash storage for advanced features like Web Services for Management (WS-MAN).  
4.2.2  
Keyboard, Video, Mouse (KVM) Redirection  
The Integrated BMC firmware supports keyboard, video, and mouse redirection over LAN. This  
feature is available remotely from the embedded web server as a Java applet. This feature is  
enabled only when the Intel® RMM3 is present. The client system must have a Java Runtime  
Environment (JRE) version 5.0 or later to run the KVM or media redirection applets.  
4.2.2.1  
Keyboard and Mouse  
The keyboard and mouse are emulated by the Integrated BMC as USB human interface devices.  
4.2.2.2  
Video  
Video output from the KVM subsystem is equivalent to the video output on the local console.  
Video redirection is available after video is initialized by the system BIOS. The KVM video  
resolution and refresh rates will always match the values set in the operating system.  
32  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Platform Management  
4.2.2.3  
Availability  
Up to two remote KVM sessions are supported. The default inactivity timeout is 30 minutes;  
however, this can be changed through the embedded web server. Remote KVM activation does  
not disable the local system keyboard, video, or mouse. Unless the feature is disabled locally,  
remote KVM is not deactivated by local system input.  
KVM sessions persist across system reset but not across an AC power loss.  
4.2.3  
Media Redirection  
The embedded web server provides a Java applet to enable remote media redirection. This may  
be used in conjunction with the remote KVM feature or as a standalone applet.  
The media redirection feature is intended to allow system administrators or users to mount a  
remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server.  
Once mounted, the remote device appears just like a local device to the server, allowing system  
administrators or users to install software (including operating systems), copy files, update the  
BIOS, and so forth, or boot the server from this device.  
The following capabilities are supported:  
ƒ
ƒ
ƒ
The operation of remotely mounted devices is independent of the local devices on the  
server. Both remote and local devices are usable in parallel  
Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the  
server.  
It is possible to boot all supported operating systems from the remotely mounted device  
and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. Refer to the  
Tested/supported Operating System List for more information.  
ƒ
ƒ
It is possible to mount at least two devices concurrently.  
The mounted device is visible to (and useable by) the managed system’s operating  
system and BIOS in both pre-boot and post-boot states.  
ƒ
ƒ
The mounted device shows up in the BIOS boot order and it is possible to change the  
BIOS boot order to boot from this remote device.  
It is possible to install an operating system on a bare metal server (no operating system  
present) using the remotely mounted device. This may also require the use of KVM-r to  
configure the operating system during install.  
If either a virtual IDE or virtual floppy device is remotely attached during system boot, both  
virtual IDE and virtual floppy are presented as bootable devices. It is not possible to present  
only a single mounted device type to the system BIOS.  
4.2.3.1  
Availability  
The default inactivity timeout is 30 minutes, but may be changed through the embedded web  
server.  
Media redirection sessions persist across system reset but not across an AC power loss.  
Revision 1.0  
33  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Platform Management  
IntelP®P Server Board S3420GP TPS  
4.2.4  
Web Services for Management (WS-MAN)  
The Integrated BMC firmware supports the Web Services for Management (WS-MAN)  
specification, version 1.0.  
4.2.5  
Local Directory Authentication Protocol (LDAP)  
The Integrated BMC firmware supports the Local Directory Authentication Protocol (LDAP)  
protocol for user authentication. Note that IPMI users/passwords and sessions are not  
supported over LDAP.  
4.2.6  
Embedded Webserver  
The Integrated BMC provides an embedded web server for out-of-band management. User  
authentication is handled by IPMI user names and passwords. Base functionality for the  
embedded web server includes:  
ƒ
ƒ
ƒ
ƒ
Power Control – Limited control based on IPMI user privilege.  
Sensor Reading – Limited access based on IPMI user privilege.  
SEL Reading – Limited access based on IPMI user privilege.  
KVM/Media Redirection – Limited access based on IPMI user privilege. Only available  
when the Intel® RMM3 is present.  
ƒ
IPMI User Management – Limited access based on IPMI user privilege.  
The web server is available on all enabled LAN channels.  
See Appendix B for Integrated BMC core sensors.  
4.3 Management Engine (ME)  
Intel Management Engine is tied to essential platform functionality. This Management Engine  
firmware includes the following applications:  
ƒ
ƒ
Platform Clocks – Tune PCH clock silicon to the parameters of a specific board,  
configure clocks at run time, power management clocks.  
Thermal Report – ME FW reports thermal and power information available only on PECI  
to host accessible registers / Embedded Controller via SMBus.  
34  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
5. BIOS User Interface  
5.1 Logo / Diagnostic Screen  
The logo / Diagnostic Screen displays in one of two forms:  
z
If Quiet Boot is enabled in the BIOS setup, a logo splash screen displays. By default,  
Quiet Boot is enabled in the BIOS setup. If the logo displays during POST, press <Esc>  
to hide the logo and display the diagnostic screen.  
z
If a logo is not present in the flash ROM or if Quiet Boot is disabled in the system  
configuration, the summary and diagnostic screen displays.  
The diagnostic screen displays the following information:  
z
z
z
z
BIOS ID  
Platform name  
Total memory detected (Total size of all installed DDR3 DIMMs)  
Processor information (Intel branded string, speed, and number of physical processor  
identified)  
z
z
Keyboards detected (if plugged in)  
Mouse devices detected (if plugged in)  
5.2 BIOS Boot Popup Menu  
The BIOS Boot Specification (BBS) provides for a Boot Popup Menu invoked by pressing the  
<F6> key during POST. The BBS popup menu displays all available boot devices. The list order  
in the popup menu is not the same as the boot order in the BIOS setup; it simply lists the  
bootable devices from which the system can be booted.  
When a User Password or Administrator Password is active in Setup, the password is to access  
the Boot Popup Menu.  
5.3 BIOS Setup utility  
The BIOS setup utility is a text-based utility that allows the user to configure the system and  
view current settings and environment information for the platform devices. The Setup utility  
controls the platform’s built-in devices, boot manager, and error manager.  
The BIOS setup interface consists of a number of pages or screens. Each page contains  
information or links to other pages. The advanced tab in Setup displays a list of general  
categories as links. These links lead to pages containing a specific category’s configuration.  
The following sections describe the look and behavior for platform setup.  
5.3.1  
Operation  
The BIOS Setup has the following features:  
Revision 1.0  
35  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
z
z
Localization - The BIOS Setup uses the Unicode standard and is capable of displaying  
setup forms in all languages currently included in the Unicode standard. The Intel®  
server board BIOS is only available in English.  
Console Redirection - The BIOS Setup is functional through console redirection over  
various terminal emulation standards. This may limit some functionality for compatibility  
(for example, color usage or some keys or key sequences or support of pointing  
devices).  
5.3.1.1  
Setup Page Layout  
The setup page layout is sectioned into functional areas. Each occupies a specific area of the  
screen and has dedicated functionality. The following table lists and describes each functional  
area.  
Table 9. BIOS Setup Page Layout  
Functional Area  
Title Bar  
Description  
The title bar is located at the top of the screen and displays the title of the form  
(page) the user is currently viewing. It may also display navigational information.  
Setup Item List  
The Setup Item List is a set of controllable and informational items. Each item in the  
list occupies the left column of the screen.  
A Setup Item may also open a new window with more options for that functionality  
on the board.  
Item Specific Help Area  
Keyboard Command Bar  
The Item Specific Help area is located on the right side of the screen and contains  
help text for the highlighted Setup Item. Help information may include the meaning  
and usage of the item, allowable values, effects of the options, and so forth.  
The Keyboard Command Bar is located at the bottom right of the screen and  
continuously displays help for keyboard special keys and navigation keys.  
5.3.1.2  
Entering BIOS Setup  
To enter the BIOS Setup, press the F2 function key during boot time when the OEM or Intel logo  
displays. The following message displays on the diagnostics screen and under the Quiet Boot  
logo screen:  
Press <F2> to enter setup  
When the Setup is entered, the Main screen displays. However, serious errors cause the  
system to display the Error Manager screen instead of the Main screen.  
5.3.1.3  
Keyboard Commands  
The bottom right portion of the Setup screen provides a list of commands used to navigate  
through the Setup utility. These commands display at all times.  
Each Setup menu page contains a number of features. Each feature is associated with a value  
field except those used for informative purposes. Each value field contains configurable  
parameters. Depending on the security option chosen and, in effect, by the password, a menu  
feature’s value may or may not be changed. If a value cannot be changed, its field is made  
inaccessible and appears grayed out.  
36  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Table 10. BIOS Setup: Keyboard Command Bar  
Key  
Option  
Execute  
Command  
Description  
<Enter>  
The <Enter> key is used to activate sub-menus when the selected feature is a sub-  
menu, or to display a pick list if a selected option has a value field, or to select a  
sub-field for multi-valued features like time and date. If a pick list is displayed, the  
<Enter> key selects the currently highlighted item, undoes the pick list, and returns  
the focus to the parent menu.  
<Esc>  
Exit  
The <Esc> key provides a mechanism for backing out of any field. When the <Esc>  
key is pressed while editing any field or selecting features of a menu, the parent  
menu is re-entered.  
When the <Esc> key is pressed in any sub-menu, the parent menu is re-entered.  
When the <Esc> key is pressed in any major menu, the exit confirmation window is  
displayed and the user is asked whether changes can be discarded. If “No” is  
selected and the <Enter> key is pressed, or if the <Esc> key is pressed, the user is  
returned to where they were before <Esc> was pressed, without affecting any  
existing settings. If “Yes” is selected and the <Enter> key is pressed, the setup is  
exited and the BIOS returns to the main System Options Menu screen.  
Select Item  
Select Item  
The up arrow is used to select the previous value in a pick list, or the previous  
option in a menu item's option list. The selected item must then be activated by  
pressing the <Enter> key.  
The down arrow is used to select the next value in a menu item’s option list, or a  
value field’s pick list. The selected item must then be activated by pressing the  
<Enter> key.  
Select Menu  
Select Field  
Change Value  
The left and right arrow keys are used to move between the major menu pages.  
The keys have no affect if a sub-menu or pick list is displayed.  
<Tab>  
-
The <Tab> key is used to move between fields. For example, <Tab> can be used  
to move from hours to minutes in the time item in the main menu.  
The minus key on the keypad is used to change the value of the current item to the  
previous value. This key scrolls through the values in the associated pick list  
without displaying the full list.  
+
Change Value  
Setup Defaults  
The plus key on the keypad is used to change the value of the current menu item to  
the next value. This key scrolls through the values in the associated pick list without  
displaying the full list. On 106-key Japanese keyboards, the plus key has a different  
scan code than the plus key on the other keyboards, but will have the same effect.  
<F9>  
Pressing <F9> causes the following to display:  
Load Optimized Defaults?  
Yes  
No  
If “Yes” is highlighted and <Enter> is pressed, all Setup fields are set to their  
default values. If “No” is highlighted and <Enter> is pressed, or if the <Esc> key is  
pressed, the user is returned to where they were before <F9> was pressed without  
affecting any existing field values.  
<F10>  
Save and Exit  
Pressing <F10> causes the following message to display:  
Save configuration and reset?  
Yes  
No  
If “Yes” is highlighted and <Enter> is pressed, all changes are saved and the Setup  
is exited. If “No” is highlighted and <Enter> is pressed, or the <Esc> key is pressed,  
the user is returned to where they were before <F10> was pressed without affecting  
any existing values.  
Revision 1.0  
37  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
5.3.1.4  
Menu Selection Bar  
The Menu Selection Bar is located at the top of the BIOS Setup Utility screen. It displays the  
major menu selections available to the user. By using the left and right arrow keys, the user can  
select the menus listed here. Some menus are hidden and become available by scrolling off the  
left or right of the current selections.  
5.3.2  
Server Platform Setup Utility Screens  
The following sections describe the screens available for the configuration of a server platform.  
In these sections, tables are used to describe the contents of each screen. These tables follow  
the following guidelines:  
z
The Setup Item, Options, and Help Text columns in the tables document the text and  
values displayed on the BIOS Setup screens.  
z
In the Options column, the default values display in bold. These values are not  
displayed in bold on the BIOS Setup screen; the bold text in this document serves as a  
reference point.  
z
z
The Comments column provides additional information where it may be helpful. This  
information does not display on the BIOS Setup screens.  
Information enclosed in angular brackets (< >) in the screen shots identifies text that  
can vary, depending on the option(s) installed. For example, <Current Date> is replaced  
by the actual current date.  
z
z
Information enclosed in square brackets ([ ]) in the tables identifies areas where the  
user must type in text instead of selecting from a provided option.  
Whenever information is changed (except Date and Time), the system requires a save  
and reboot to take place. Pressing <ESC> discards the changes and boots the system  
according to the boot order set from the last boot.  
5.3.2.1  
Main Screen  
The Main screen is the first screen displayed when the BIOS Setup is entered, unless an error  
occurred. If an error occurred, the Error Manager screen displays instead.  
38  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Advance  
BIOS User Interface  
Boot Manager  
Main  
Security  
Server Management  
Boot Options  
d
Logged in as <Administrator or User>  
Platform ID  
<Platform Identification String>  
System BIOS  
Version  
SXXXX.86B.xx.yy.zzzz  
<MM/DD/YYYY>  
Build Date  
Memory  
Total Memory  
<How much memory is installed>  
Quiet Boot  
Enabled/Disabled  
Enabled/Disabled  
POST Error Pause  
System Date  
System Time  
<Current Date>  
<Current Time>  
Figure 15. Setup Utility – Main Screen Display  
Table 11. Setup Utility – Main Screen Fields  
Setup Item  
Logged in as  
Options  
Help Text  
Comments  
Information only. Displays  
password level that setup is  
running in: Administrator or User.  
With no passwords set,  
Administrator is the default mode.  
Platform ID  
Information only. Displays the  
Platform ID.  
LX SKU: S3420GPLX  
LC SKU: S3420GPLC  
V SKU: S3420GPV  
System BIOS  
Version  
Information only. Displays the  
current BIOS version.  
xx = major version  
yy = minor version  
zzzz = build number  
Build Date  
Memory  
Information only. Displays the  
current BIOS build date.  
Revision 1.0  
39  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Comments  
Setup Item  
Options  
Help Text  
Size  
Information only. Displays the  
total physical memory installed in  
the system, in MB or GB. The term  
physical memory indicates the total  
memory discovered in the form of  
installed DDR3 DIMMs.  
Quiet Boot  
[Enabled] – Display the logo screen  
during POST.  
Enabled  
Disabled  
[Disabled] – Display the diagnostic  
screen during POST.  
POST Error Pause  
Enabled  
[Enabled] – Go to the Error  
Manager for critical POST errors.  
If enabled, the POST Error Pause  
option takes the system to the error  
manager to review the errors when  
major errors occur. Minor and fatal  
error displays are not affected by  
this setting.  
Disabled  
[Disabled] – Attempt to boot and do  
not go to the Error Manager for  
critical POST errors.  
System Date  
System Time  
[Day of week  
MM/DD/YYYY]  
System Date has configurable  
fields for Month, Day, and Year.  
Use [Enter] or [Tab] key to select  
the next field.  
Use [+] or [-] key to modify the  
selected field.  
[HH:MM:SS]  
System Time has configurable  
fields for Hours, Minutes, and  
Seconds.  
Hours are in 24-hour format.  
Use [Enter] or [Tab] key to select  
the next field.  
Use [+] or [-] key to modify the  
selected field.  
5.3.2.2  
Advanced Screen  
The Advanced screen provides an access point to configure several options. On this screen, the  
user selects the option they want to configure. Configurations are performed on the selected  
screen, and not directly on the Advanced screen.  
To access this screen from the Main screen, press the right arrow until the Advanced screen is  
chosen.  
40  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Advance  
BIOS User Interface  
Boot Manager  
Main  
Security  
Server Management Boot Options  
d
Processor Configuration  
Memory Configuration  
Mass Storage Controller Configuration  
Serial Port Configuration  
USB Configuration  
PCI Configuration  
System Acoustic and Performance Configuration  
Figure 16. Setup Utility – Advanced Screen Display  
Table 12. Setup Utility – Advanced Screen Display Fields  
Setup Item  
Processor Configuration  
Help Text  
View/Configure processor information and  
settings.  
Memory Configuration  
View/Configure memory information and  
settings.  
Mass Storage Controller Configuration  
Serial Port Configuration  
View/Configure mass storage controller  
information and settings.  
View/Configure serial port information and  
settings.  
View/Configure USB information and  
settings.  
USB Configuration  
PCI Configuration  
View/Configure PCI information and  
settings.  
System Acoustic and Performance  
Configuration  
View/Configure system acoustic and  
performance information and settings.  
5.3.2.2.1  
Processor Screen  
The Processor screen allows the user to view the processor core frequency, system bus  
frequency, and to enable or disable several processor options. This screen also allows the user  
to view information about a specific processor.  
To access this screen from the Main screen, select Advanced > Processor.  
Revision 1.0  
41  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Advanced  
Processor Configuration  
Processor Socket  
Processor ID  
CPU 1  
<CPUID>  
<Proc Freq>  
<Rev data>  
Processor Frequency  
Microcode Revision  
L1 Cache RAM  
L2 Cache RAM  
Size of Cache  
Size of Cache  
L3 Cache RAM  
Size of Cache  
Processor 1 Version  
<ID string from Processor 1>  
Current QPI Link Speed  
<Slow / Fast >  
QPI Link Frequency  
<Unknown GT/s / 4.8 GT/s / 5.866 GT/s / 6.4 GT/s>  
Enabled / Disabled  
Intel® Turbo Boost Technology  
Enhanced Intel SpeedStep® Tech  
Enabled / Disabled  
Intel® Hyper-Threading Technology  
Core Multi-Processing  
Execute Disable Bit  
Intel® Virtualization Technology  
Intel® VT for Directed I/O  
Interrupt Remapping  
Enabled / Disabled  
All / 1 / 2  
Enabled / Disabled  
Enabled/ Disabled  
Enabled/ Disabled  
Enabled / Disabled  
Enabled/ Disabled  
Enabled / Disabled  
Enabled / Disabled  
Enabled / Disabled  
Enabled / Disabled  
Coherency Support  
ATS Support  
Pass-through DMA Support  
Hardware Prefetcher  
Adjacent Cache Line Prefetch  
Figure 17. Setup Utility – Processor Configuration Screen Display  
Table 13. Setup Utility – Processor Configuration Screen Fields  
Setup Item  
Processor ID  
Options  
Help Text  
Comments  
Information only. Processor  
CPUID.  
Processor Frequency  
Core Frequency  
Information only. Current  
frequency of the processor.  
Information only. Frequency  
at which the processor are  
currently running.  
42  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Comments  
Setup Item  
Options  
Help Text  
Microcode Revision  
Information only. Revision of  
the loaded microcode.  
L1 Cache RAM  
L2 Cache RAM  
L3 Cache RAM  
Processor Version  
Information only. Size of the  
Processor L1 Cache.  
Information only. Size of the  
Processor L2 Cache  
Information only. Size of the  
Processor L3 Cache.  
Information only. ID string  
from the Processor.  
Current QPI Link Speed  
QPI Link Frequency  
Information only. Current  
speed that the QPI Link is  
using.  
Information only. Current  
frequency that the QPI Link is  
using.  
Intel® Turbo Boost  
Technology  
Intel® Turbo Boost Technology allows the  
processor to automatically increase its  
frequency if it is running below power,  
temperature, and current specifications.  
This option is only visible if all  
processor in the system  
support Intel® Turbo Boost  
Technology.  
Enabled  
Disabled  
Enhanced Intel  
Enhanced Intel SpeedStep® Technology  
allows the system to dynamically adjust  
processor voltage and core frequency, which  
can result in decreased average power  
consumption and decreased average heat  
production.  
Enabled  
SpeedStep® Technology  
Disabled  
Contact your OS vendor regarding OS  
support of this feature.  
Intel® HT Technology allows multithreaded  
software applications to execute threads in  
parallel within the processor.  
Intel® Hyper-Threading  
Technology  
Enabled  
Disabled  
Contact your OS vendor regarding OS  
support of this feature.  
Core Multi-Processing  
Execute Disable Bit  
Enable 1, 2 or All cores of installed  
processor packages.  
All  
1
2
Execute Disable Bit can help prevent certain  
classes of malicious buffer overflow attacks.  
Enabled  
Disabled  
Contact your OS vendor regarding OS  
support of this feature.  
Intel® Virtualization Technology allows a  
platform to run multiple operating systems  
and applications in independent partitions.  
Intel® Virtualization  
Technology  
Enabled  
Disabled  
Note: A change to this option requires the  
system to be powered off and then back on  
before the setting takes effect.  
Enabled  
Enable/Disable Intel® Virtualization  
Technology for Directed I/O.  
Intel® Virtualization  
Technology for Directed  
I/O  
Disabled  
Report the I/O device assignment to VMM  
through DMAR ACPI Tables  
Interrupt Remapping  
Enable/Disable Intel® VT-d Interrupt  
Remapping support.  
Only visible when Intel®  
Virtualization Technology for  
Directed I/O is enabled.  
Enabled  
Disabled  
Revision 1.0  
43  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Help Text Comments  
Setup Item  
Options  
Enabled  
Coherency Support  
Enable/Disable Intel® VT-d Coherency  
support.  
Only visible when Intel®  
Virtualization Technology for  
Directed I/O is enabled.  
Disabled  
ATS Support  
Enable/Disable Intel® VT-d Address  
Translation Services (ATS) support.  
Only visible when Intel®  
Virtualization Technology for  
Directed I/O is enabled.  
Enabled  
Disabled  
Pass-through DMA  
Support  
Enable/Disable Intel® VT-d Pass-through  
DMA support.  
Only visible when Intel®  
Virtualization Technology for  
Directed I/O is enabled.  
Enabled  
Disabled  
Hardware Prefetcher  
Hardware Prefetcher is a speculative  
prefetch unit within the processor(s).  
Enabled  
Disabled  
Note: Modifying this setting may affect  
system performance.  
Adjacent Cache Line  
Prefetch  
[Enabled] - Cache lines are fetched in pairs  
(even line + odd line).  
Enabled  
Disabled  
[Disabled] - Only the current cache line  
required is fetched.  
Note: Modifying this setting may affect  
system performance.  
5.3.2.2.2  
Memory Screen  
The Memory screen allows the user to view details about the system memory DDR3 DIMMs  
installed. This screen also allows the user to open the Configure Memory RAS and Performance  
screen.  
To access this screen from the Main screen, select Advanced > Memory.  
44  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Advanced  
Memory Configuration  
Total Memory  
<Total Physical Memory Installed in System>  
Effective Memory  
Current Configuration  
Current Memory Speed  
<Total Effective Memory>  
<Independent >  
<Speed that installed memory is running at.>  
DIMM Information  
DIMM_A1  
Installed/Not Installed/Failed/Disabled/Spare Unit  
Installed/Not Installed/Failed/Disabled/Spare Unit  
Installed/Not Installed/Failed/Disabled/Spare Unit  
Installed/Not Installed/Failed/Disabled/Spare Unit  
Installed/Not Installed/Failed/Disabled/Spare Unit  
Installed/Not Installed/Failed/Disabled/Spare Unit  
DIMM_A2  
DIMM_A3  
DIMM_B1  
DIMM_B2  
DIMM_B3  
Figure 18. Setup Utility – Memory Configuration Screen Display  
Table 14. Setup Utility – Memory Configuration Screen Fields  
Setup Item  
Total Memory  
Comments  
Information only. The amount of memory available in the system  
in the form of installed DDR3 DIMMs in units of MB or GB.  
Effective Memory  
Information only. The amount of memory available to the  
operating system in MB or GB.  
The Effective Memory is the difference between the Total Physical  
Memory and the sum of all memory reserved for internal usage,  
RAS redundancy and SMRAM. This difference includes the sum of  
all DDR3 DIMMs that failed Memory BIST during POST, or were  
disabled by the BIOS during memory discovery phase to optimize  
memory configuration.  
Current Configuration  
Information only. Displays one of the following:  
Independent Mode: System memory is configured for optimal  
performance and efficiency and no RAS is enabled.  
Sparing Mode: System memory is configured for RAS with  
optimal effective memory.  
Revision 1.0  
45  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Setup Item  
Comments  
Current Memory  
Speed  
Information only. Displays the speed the memory is running at.  
DIMM_ XY  
Displays the state of each DIMM socket present on the board.  
Each DIMM socket field reflects one of the following possible  
states:  
Installed: There is a DDR3 DIMM installed in this slot.  
Not Installed: There is no DDR3 DIMM installed in this slot.  
Disabled: The DDR3 DIMM installed in this slot was disabled by  
the BIOS to optimize memory configuration.  
Failed: The DDR3 DIMM installed in this slot is faulty /  
malfunctioning.  
Spare Unit: The DDR3 DIMM is functioning as a spare unit for  
memory RAS purposes.  
Note: X denotes the Channel Identifier and Y denote the DIMM  
Identifier within the Channel.  
5.3.2.2.3  
Mass Storage Controller Screen  
The Mass Storage screen allows the user to configure the SATA/SAS controller when it is  
present on the baseboard, midplane, or backplane of an Intel system.  
To access this screen from the Main menu, select Advanced > Mass Storage.  
Advanced  
Mass Storage Controller Configuration  
Intel® Entry SAS RAID Module  
Configure Intel® Entry SAS RAID Module  
Onboard SATA Controller  
Enabled / Disabled  
LSI ® Integrated RAID / Intel® ESRTII  
Enabled / Disabled  
ENHANCED / COMPATIBILITY / AHCI / SW  
Configure SATA Mode  
RAID  
SATA Port 0  
SATA Port 1  
SATA Port 2  
SATA Port 3  
SATA Port 4  
SATA Port 5  
Not Installed/<Drive Info.>  
Not Installed/<Drive Info.>  
Not Installed/<Drive Info.>  
Not Installed/<Drive Info.>  
Not Installed/<Drive Info.>  
Not Installed/<Drive Info.>  
Figure 19. Setup Utility – Mass Storage Controller Configuration Screen Display  
Table 15. Setup Utility – Mass Storage Controller Configuration Screen Fields  
Setup Item  
Options  
Help Text  
Comments  
46  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Comments  
Setup Item  
Options  
Enabled  
Help Text  
Unavailable if the SAS Module  
(AXX4SASMOD) is not present.  
Intel® Entry SAS RAID  
Module  
Enabled or Disable the Intel® SAS  
Entry RAID Module  
Disabled  
Note: This option is not  
available on some models.  
Configure Intel® Entry  
SAS RAID Module  
LSI® Integrated RAID - Supports  
Unavailable if the SAS Module  
RAID 0, RAID 1, and RAID 1e, as (AXX4SASMOD) is disabled or  
LSI® Integrated  
RAID  
Intel® ESRTII  
well as IT (JBOD) mode;  
Intel® ESRTII - Intel® Embedded  
Server RAID Technology II, which  
supports RAID 0, RAID 1, RAID  
10.  
not present  
Note: This option is not  
available on some models.  
Onboard SATA  
Controller  
Onboard Serial ATA (SATA)  
controller.  
Enabled  
Disabled  
SATA Mode  
[ENHANCED] - Supports up to 6  
SATA ports with IDE Native  
Mode.  
Disappears when the Onboard  
SATA Controller is disabled.  
ENHANCED  
Compatibility  
AHCI  
[COMPATIBILITY] - Supports up  
to 4 SATA ports[0/1/2/3] with IDE  
Legacy mode and 2 SATA  
SW RAID  
ports[4/5] with IDE Native Mode.  
[AHCI] - Supports all SATA ports  
using the Advanced Host  
Controller Interface.  
[SW RAID] - Supports  
configuration of SATA ports for  
RAID via RAID configuration  
software.  
Intel® Matrix RAID Technology  
with Software RAID levels 0/1/10  
and 5.  
SATA Port 0  
SATA Port 1  
SATA Port 2  
SATA Port 3  
SATA Port 4  
SATA Port 5  
< Not Installed /  
Drive  
information>  
Information only. This field is  
unavailable when RAID Mode is  
enabled.  
< Not Installed /  
Drive  
information>  
Information only. This field is  
unavailable when RAID Mode is  
enabled.  
< Not Installed /  
Drive  
information>  
Information only. This field is  
unavailable when RAID Mode is  
enabled.  
< Not Installed /  
Drive  
information>  
Information only. This field is  
unavailable when RAID Mode is  
enabled.  
< Not Installed /  
Drive  
information>  
Information only. This field is  
unavailable when RAID Mode is  
enabled.  
< Not Installed /  
Drive  
information>  
Information only. This field is  
unavailable when RAID Mode is  
enabled.  
5.3.2.2.4  
Serial Ports Screen  
The Serial Ports screen allows the user to configure the Serial A [COM 1] and Serial B [COM2]  
ports.  
To access this screen from the Main screen, select Advanced > Serial Port.  
Revision 1.0  
47  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Advanced  
Serial Port Configuration  
Serial A Enable  
Address  
Enabled/Disabled  
3F8h / 2F8h / 3E8h / 2E8h  
3 or 4  
IRQ  
Serial B Enable  
Address  
Enabled/Disabled  
3F8h / 2F8h / 3E8h / 2E8h  
3 or 4  
IRQ  
Figure 20. Setup Utility – Serial Port Configuration Screen Display  
Table 16. Setup Utility – Serial Ports Configuration Screen Fields  
Setup Item  
Options  
Enabled  
Help Text  
Serial A  
Enable  
Enable or Disable Serial port A.  
Disabled  
3F8h  
2F8h  
3E8h  
2E8h  
3
Address  
Select Serial port A base I/O address.  
IRQ  
Select Serial port A interrupt request (IRQ) line.  
Enable or Disable Serial port B.  
4
Serial B  
Enable  
Enabled  
Disabled  
3F8h  
2F8h  
3E8h  
2E8h  
3
Address  
Select Serial port B base I/O address.  
IRQ  
Select Serial port B interrupt request (IRQ).  
4
5.3.2.2.5  
USB Configuration Screen  
The USB Configuration screen allows the user to configure the USB controller options.  
To access this screen from the Main screen, select Advanced > USB Configuration.  
48  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Advanced  
USB Configuration  
Detected USB Devices  
<Total USB Devices in System>  
USB Controller  
Enabled / Disabled  
Enabled / Disabled / Auto  
Enabled / Disabled  
Enabled / Disabled  
Legacy USB Support  
Port 60/64 Emulation  
Make USB Devices Non-Bootable  
USB Mass Storage Device Configuration  
10 seconds / 20 seconds / 30 seconds / 40  
Device Reset timeout  
seconds  
Mass Storage Devices:  
<Mass storage devices one line/device>  
Auto / Floppy/Forced FDD/Hard Disk/CD-ROM  
Enabled / Disabled  
USB 2.0 controller  
Figure 21. Setup Utility – USB Controller Configuration Screen Display  
Table 17. Setup Utility – USB Controller Configuration Screen Fields  
Setup Item  
Options  
Help Text  
Comments  
Detected USB  
Devices  
Information only. Shows the number  
of USB devices in the system.  
USB Controller  
[Enabled] - All onboard USB controllers are turned on and  
accessible by the OS.  
Enabled  
Disabled  
[Disabled] - All onboard USB controllers are turned off and  
inaccessible by the OS.  
Legacy USB  
Support  
USB device boot support and PS/2 emulation for USB  
keyboard and USB mouse devices.  
Grayed out if the USB Controller is  
disabled.  
Enabled  
Disabled  
Auto  
[Auto] - Legacy USB support is enabled if a USB device is  
attached.  
Port 60/64  
Emulation  
I/O port 60h/64h emulation support.  
Grayed out if the USB Controller is  
disabled.  
Enabled  
Note: This may be needed for legacy USB keyboard  
support when using an OS that is USB unaware.  
Disabled  
Make USB  
Devices Non-  
Bootable  
Enabled  
Exclude USB in Boot Table.  
Grayed out if the USB Controller is  
disabled.  
[Enabled] - This removes all USB Mass Storage devices  
as Boot options.  
Disabled  
[Disabled] - This allows all USB Mass Storage devices as  
Boot options.  
Revision 1.0  
49  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Comments  
Setup Item  
Options  
10 sec  
Help Text  
Device Reset  
timeout  
USB Mass Storage device Start Unit command timeout.  
Grayed out if the USB Controller is  
disabled.  
Setting to a larger value provides more time for a mass  
storage device to be ready, if needed.  
20 sec  
30 sec  
40 sec  
One line for each  
mass storage  
device in system  
[Auto] - USB devices less than 530 MB are emulated as  
floppies.  
Hidden if no USB Mass storage  
devices are installed.  
Auto  
Floppy  
[Forced FDD] - HDD formatted drive are emulated as a  
FDD (e.g., ZIP drive).  
Grayed out if the USB Controller is  
disabled.  
Forced FDD  
Hard Disk  
CD-ROM  
This setup screen can show a  
maximum of eight devices on this  
screen. If more than eight devices  
are installed in the system, the USB  
Devices Enabled shows the correct  
count, but only displays the first  
eight devices here.  
USB 2.0  
Onboard USB ports are enabled to support USB 2.0 mode. Grayed out if the USB Controller is  
Enabled  
controller  
disabled.  
Contact your OS vendor regarding OS support of this  
feature.  
Disabled  
5.3.2.2.6  
PCI Screen  
The PCI Screen allows the user to configure the PCI add-in cards, onboard NIC controllers, and  
video options.  
To access this screen from the Main screen, select Advanced > PCI.  
Advanced  
PCI Configuration  
Maximize Memory below 4GB  
Memory Mapped I/O above 4GB  
Onboard Video  
Enabled / Disabled  
Enabled / Disabled  
Enabled / Disabled  
Enabled / Disabled  
Enabled / Disabled  
Enabled / Disabled  
Enabled / Disabled  
Dual Monitor Video  
Onboard NIC1 ROM  
Onboard NIC2 ROM  
Onboard NIC iSCSI ROM  
NIC 1 MAC Address  
NIC 2 MAC Address  
<MAC #>  
<MAC #>  
Figure 22. Setup Utility – PCI Configuration Screen Display  
50  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Comments  
Table 18. Setup Utility – PCI Configuration Screen Fields  
Setup Item  
Options  
Enabled  
Disabled  
Help Text  
Maximize Memory  
below 4GB  
If enabled. the BIOS maximizes usage of memory  
below 4 GB for OS without PAE by limiting PCIE  
Extended Configuration Space to 64 buses.  
Memory Mapped I/O  
above 4GB  
Enabled  
Enable or disable memory mapped I/O of 64-bit  
PCI devices to 4 GB or greater address space.  
Disabled  
Onboard Video  
Onboard video controller.  
When disabled, the system  
requires an add-in video  
card for the video to be  
seen.  
Enabled  
Disabled  
Warning: System video is completely disabled if  
this option is disabled and an add-in video adapter  
is not installed.  
Note: This option is not  
available on some models.  
Dual Monitor Video  
Onboard NIC1 ROM  
Enabled  
If enabled. both the onboard video controller and  
an add-in video adapter are enabled for system  
video. The onboard video controller becomes the  
primary video device.  
Note: This option does not  
appear on some models.  
Disabled  
If enabled. loads the embedded option ROM for  
the onboard network controllers.  
Enabled  
Disabled  
Warning: If [Disabled] is selected, NIC1 cannot  
be used to boot or wake the system.  
Onboard NIC2 ROM  
If enabled. loads the embedded option ROM for  
the onboard network controllers.  
Enabled  
Disabled  
Warning: If [Disabled] is selected, NIC2 cannot  
be used to boot or wake the system.  
Onboard NIC iSCSI  
ROM  
Enabled  
If enabled. loads the embedded option ROM for  
the onboard network controllers.  
This option is grayed out  
and not accessible if either  
the NIC1 or NIC2 ROMs  
are enabled.  
Disabled  
Warning: If [Disabled] is selected, NIC1 and NIC2  
cannot be used to boot or wake the system.  
Note: This option is not  
available on some models.  
NIC 1 MAC Address  
NIC 2 MAC Address  
No entry  
allowed  
Information only. 12 hex  
digits of the MAC address.  
No entry  
allowed  
Information only. 12 hex  
digits of the MAC address.  
5.3.2.2.7  
System Acoustic and Performance Configuration  
The System Acoustic and Performance Configuration screen allows the user to configure the  
thermal characteristics of the system.  
To access this screen from the Main screen, select Advanced > System Acoustic and  
Performance Configuration.  
Revision 1.0  
51  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Advanced  
System Acoustic and Performance Configuration  
Set Throttling Mode  
Altitude  
Auto / CLTT / OLTT  
300m or less / 301m-900m / 901m – 1500m / Higher than 1500m  
Performance, Acoustic  
Set Fan Profile  
Figure 23. Setup Utility – System Acoustic and Performance Configuration Screen Display  
Table 19. Setup Utility – System Acoustic and Performance Configuration Screen Fields  
Setup Item  
Options  
Help Text  
[Auto] – Auto Throttling mode.  
Comments  
Set Throttling  
Mode  
Auto  
CLTT  
OLTT  
Note: The OLTT  
option is shown for  
informational  
purposes only. If  
the user selects  
OLTT, the BIOS  
overrides that  
[CLTT] – Closed Loop Thermal Throttling Mode.  
[OLTT] – Open Loop Thermal Throttling Mode.  
selection if the  
system can support  
CLTT. OLTT is  
configured only when  
UDIMMs without  
Thermal Sensors are  
installed.  
Altitude  
300m or less  
[300m or less] (980ft or less)  
Note: This option is  
not available on  
some models.  
Optimal performance setting near sea level.  
[301m - 900m] (980ft - 2950ft)  
301m-900m  
901m-1500m  
Higher than 1500m  
Optimal performance setting at moderate elevation.  
[901m – 1500m] (2950ft – 4920ft)  
Optimal performance setting at high elevation.  
[Higher than 1500m] (4920ft or greater)  
Optimal performance setting at the highest elevations.  
52  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Comments  
Setup Item  
Options  
Performance  
Acoustics  
Help Text  
Set Fan Profile  
[Performance] - Fan control provides primary system  
cooling before attempting to throttle memory.  
This option is grayed  
out if CLTT is  
enabled.  
[Acoustic] - The system will favor using throttling of  
memory over boosting fans to cool the system if  
thermal thresholds are met.  
Note: This option is  
not available on  
some models.  
5.3.2.3  
Security Screen  
The Security screen allows the user to enable and set the user and administrative password  
and to lock out the front panel buttons so they cannot be used.  
Trusted Platform Module (TPM) security is NOT supported on the Intel® Server S3420GP board.  
To access this screen from the Main screen, select Security.  
Main  
Advanced  
Security  
Server Management  
Boot Options  
Boot Manager  
<Installed/Not Installed>  
<Installed/Not Installed>  
Administrator Password Status  
User Password Status  
Set Administrator Password  
Set User Password  
[1234aBcD]  
[1234aBcD]  
Front Panel Lockout  
Enabled / Disabled  
Figure 24. Setup Utility – Security Configuration Screen Display  
Table 20. Setup Utility – Security Configuration Screen Fields  
Setup Item  
Options  
Help Text  
Comments  
Administrator Password <Installed  
Status  
Information only. Indicates  
the status of the  
administrator password.  
Not Installed>  
User Password Status  
<Installed  
Not Installed>  
Information only. Indicates  
the status of the user  
password.  
Revision 1.0  
53  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
Setup Item  
IntelP®P Server Board S3420GP TPS  
Help Text Comments  
Options  
[123aBcD]  
Set Administrator  
Password  
Administrator password is used to  
control change access in BIOS Setup  
Utility.  
This option is only to control  
access to the setup.  
Administrator has full  
access to all the setup  
items. Clearing the  
Administrator password also  
clears the user password.  
Only alphanumeric characters can be  
used. Maximum length is 7 characters. It  
is case sensitive.  
Note: Administrator password must be  
set in order to use the user account.  
Set User Password  
[123aBcD]  
User password is used to control entry  
access to BIOS Setup Utility.  
Available only if the  
administrator password is  
installed. This option only  
protects the setup.  
Only alphanumeric characters can be  
used. Maximum length is 7 characters. It  
is case sensitive.  
User password only has  
limited access to the setup  
items.  
Note: Removing the administrator  
password also automatically removes  
the user password.  
Front Panel Lockout  
Enabled  
If enabled, locks the power button and  
reset button on the system's front panel.  
If [Enabled] is selected, power and reset  
must be controlled via a system  
management interface.  
Disabled  
5.3.2.4  
Server Management Screen  
The Server Management screen allows the user to configure several server management  
features. This screen also provides an access point to the screens for configuring console  
redirection and displaying system information.  
To access this screen from the Main screen, select Server Management.  
54  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Advance  
BIOS User Interface  
Main  
Security  
Server Management  
Boot Options Boot Manager  
d
Assert NMI on SERR  
Assert NMI on PERR  
Enabled / Disabled  
Enabled / Disabled  
Resume on AC Power Loss  
Clear System Event Log  
Stay Off / Last state / Reset  
Enabled / Disabled  
FRB-2 Enable  
Enabled / Disabled  
O/S Boot Watchdog Timer  
Enabled / Disabled  
Power off / Reset  
O/S Boot Watchdog Timer Policy  
O/S Boot Watchdog Timer Timeout  
ACPI 1.0 Support  
5 minutes / 10 minutes / 15 minutes / 20 minutes  
Enabled / Disabled  
Plug & Play BMC Detection  
Enabled / Disabled  
Console Redirection  
System Information  
Figure 25. Setup Utility – Server Management Configuraiton Screen Display  
Table 21. Setup Utility – Server Management Configuration Screen Fields  
Setup Item  
Options  
Enabled  
Disabled  
Help Text  
Comments  
Assert NMI on SERR  
On SERR, generate an NMI and log an error.  
Note: [Enabled] must be selected for the Assert NMI  
on PERR setup option to be visible.  
Assert NMI on PERR  
On PERR, generate an NMI and log an error.  
Enabled  
Note: This option is only active if the Assert NMI on  
SERR option is [Enabled] selected.  
Disabled  
Resume on AC Power  
Loss  
System action to take on AC power loss recovery.  
[Stay Off] - System stays off.  
Stay Off  
Last state  
Reset  
[Last State] - System returns to the same state before  
the AC power loss.  
[Reset] - System powers on.  
Clear System Event  
Log  
Enabled  
If enabled, clears the System Event Log. All current  
entries will be lost.  
Disabled  
Note: This option is reset to [Disabled] after a reboot.  
Fault Resilient Boot (FRB).  
FRB-2 Enable  
Enabled  
If enabled, the BIOS programs the BMC watchdog  
timer for approximately 6 minutes. If the BIOS does  
not complete POST before the timer expires, the BMC  
resets the system.  
Disabled  
Revision 1.0  
55  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
Setup Item  
IntelP®P Server Board S3420GP TPS  
Comments  
Options  
Disabled  
Help Text  
O/S Boot Watchdog  
Timer  
Enabled  
If enabled, the BIOS programs the watchdog timer  
with the timeout value selected. If the OS does not  
complete booting before the timer expires, the BMC  
resets the system and an error is logged.  
Requires OS support or Intel Management Software.  
O/S Boot Watchdog  
Timer Policy  
If the OS boot watchdog timer is enabled, this is the  
system action taken if the watchdog timer expires.  
Grayed out when the O/S  
Boot Watchdog Timer is  
disabled.  
Power Off  
Reset  
[Reset] - System performs a reset.  
[Power Off] - System powers off.  
O/S Boot Watchdog  
Timer Timeout  
5 minutes  
10 minutes  
15 minutes  
20 minutes  
Enabled  
If the OS watchdog timer is enabled, this is the  
timeout value used by the BIOS to configure the  
watchdog timer.  
Grayed out when the O/S  
Boot Watchdog Timer is  
disabled.  
Plug & Play BMC  
Detection  
If enabled, the BMC is detectable by OSs that support  
plug and play loading of an IPMI driver. Do not enable  
if your OS does not support this driver.  
Disabled  
ACPI 1.0 Support  
Enabled  
[Enabled] - Publish ACPI 1.0 version of FADT in Root Needs to be [Enabled] for  
System Description Table.  
Microsoft Windows 2000*  
support.  
Disabled  
This may be required for compatibility with OS  
versions that only support ACPI 1.0.  
Console Redirection  
System Information  
View/Configure console redirection information and  
settings.  
Takes the user to the  
Console Redirection  
screen.  
View system information  
Takes the user to the  
System Information  
screen.  
5.3.2.4.1  
Console Redirection Screen  
The Console Redirection screen allows the user to enable or disable console redirection and to  
configure the connection options for this feature.  
To access this screen from the Main screen, select Server Management > Console  
Redirection.  
Server Management  
Console Redirection  
Console Redirection  
Flow Control  
Disabled / Serial Port A / Serial Port B  
None / RTS/CTS  
Baud Rate  
9.6k / 19.2k / 38.4k / 57.6k / 115.2k  
PC-ANSI / VT100 / VT100+ / VT-UTF8  
Disabled / Enabled  
Terminal Type  
Legacy OS Redirection  
Figure 26. Setup Utility – Console Redirection Screen Display  
56  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Table 22. Setup Utility – Console Redirection Configuration Fields  
Setup Item  
Options  
Help Text  
Console Redirection  
Console redirection allows a serial port to be used for server  
management tasks.  
Disabled  
Serial Port A  
Serial Port B  
[Disabled] - No console redirection.  
[Serial Port A] - Configure serial port A for console redirection.  
[Serial Port B] - Configure serial port B for console redirection.  
Enabling this option disables the display of the Quiet Boot logo  
screen during POST.  
Flow Control  
Baud Rate  
Flow control is the handshake protocol.  
None  
Setting must match the remote terminal application.  
[None] - Configure for no flow control.  
RTS/CTS  
[RTS/CTS] - Configure for hardware flow control.  
9600  
Serial port transmission speed. Setting must match the remote  
terminal application.  
19.2K  
38.4K  
57.6K  
115.2K  
PC-ANSI  
VT100  
Terminal Type  
Character formatting used for console redirection. Setting must  
match the remote terminal application.  
VT100+  
VT-UTF8  
Disabled  
Enabled  
Legacy OS  
Redirection  
This option enables legacy OS redirection (i.e., DOS) on serial  
port. If it is enabled, the associated serial port is hidden from the  
legacy OS.  
5.3.2.5  
Server Management System Information Screen  
The Server Management System Information screen allows the user to view part numbers,  
serial numbers, and firmware revisions.  
To access this screen from the Main screen, select Server Management > System  
Information.  
Revision 1.0  
57  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
System Information  
IntelP®P Server Board S3420GP TPS  
Server Management  
Board Part Number  
Board Serial Number  
System Part Number  
System Serial Number  
Chassis Part Number  
Chassis Serial Number  
BMC Firmware Revision  
HSC Firmware Revision  
ME Firmware Revision  
SDR Revision  
UUID  
Figure 27. Setup Utility – Server Management System Information Screen Display  
Table 23. Setup Utility – Server Management System Information Fields  
Setup Item  
Comments  
Information only  
Information only  
Information only  
Information only  
Information only  
Information only  
Information only  
Information only  
Information only  
Information only  
Information only  
Board Part Number  
Board Serial Number  
System Part Number  
System Serial Number  
Chassis Part Number  
Chassis Serial Number  
BMC Firmware Revision  
HSC Firmware Revision  
ME Firmware Revision  
SDR Revision  
UUID  
5.3.2.6  
Boot Options Screen  
The Boot Options screen displays any bootable media encountered during POST, and allows  
the user to configure the preferred boot device.  
To access this screen from the Main screen, select Boot Options.  
58  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Advance  
BIOS User Interface  
Boot Manager  
Main  
Security  
Server Management Boot Options  
d
System Boot Timeout  
<0 - 65535>  
Boot Option #1  
Boot Option #2  
Boot Option #x  
<Available Boot devices>  
<Available Boot devices>  
<Available Boot devices>  
Hard Disk Order  
CDROM Order  
Network Device Order  
Delete Boot Option  
EFI Optimized Boot  
Boot Option Retry  
Enabled / Disabled  
Enabled / Disabled  
Figure 28. Setup Utility – Boot Options Screen Display  
Table 24. Setup Utility – Boot Options Screen Fields  
Setup Item  
Boot Timeout  
Options  
0 - 65535  
Help Text  
Comments  
The number of seconds the BIOS  
should pause at the end of POST to  
After entering the preferred  
timeout, press the Enter key  
allow the user to press the [F2] key for to register that timeout value  
entering the BIOS Setup utility.  
to the system. These  
settings are in seconds.  
Valid values are 0-65535. Zero is the  
default. A value of 65535 causes the  
system to go to the Boot Manager  
menu and wait for user input for every  
system boot.  
Boot Option #x  
Hard Disk Order  
Available boot  
devices.  
Set system boot order by selecting the  
boot option for this position.  
Set the order of the legacy devices in  
this group.  
Visible when one or more  
hard disk drives are in the  
system.  
CDROM Order  
Floppy Order  
Set the order of the legacy devices in  
this group.  
Visible when one or more  
CD-ROM drives are in the  
system.  
Set the order of the legacy devices in  
this group.  
Visible when one or more  
floppy drives are in the  
system.  
Revision 1.0  
59  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Help Text Comments  
Setup Item  
Options  
Network Device Order  
Set the order of the legacy devices in  
this group.  
Visible when one or more of  
these devices are available  
in the system.  
BEV Device Order  
Set the order of the legacy devices in  
this group.  
Visible when one or more of  
these devices are available  
in the system.  
Add New Boot Option  
Add a new EFI boot option to the boot This option is only visible if  
order.  
an EFI bootable device is  
available to the system (for  
example, a USB drive).  
Delete Boot Option  
EFI Optimized Boot  
Boot Option Retry  
Remove an EFI boot option from the  
boot order.  
If the EFI shell is deleted,  
you can restore it by setting  
CMOS defaults (F9).  
Enabled  
If enabled, the BIOS only loads  
modules required for booting EFI-  
aware Operating Systems.  
Disabled  
Enabled  
Disabled  
If enabled, this continually retries non-  
EFI-based boot options without  
waiting for user input.  
If all types of bootable devices are installed in the system, the default boot order is:  
1. CD/DVD-ROM  
2. Floppy Disk Drive  
3. Hard Disk Drive  
4. PXE Network Device  
5. BEV (Boot Entry Vector) Device  
6. EFI Shell and EFI Boot paths  
5.3.2.6.1  
Delete Boot Option Screen  
The Delete Boot Option screen allows the user to remove an EFI boot option from the boot  
order.  
To access this screen from the Main screen, select Boot Options > Delete Boot Options.  
Boot Options  
Delete Boot Option  
Delete Boot Option  
Select one to Delete / Internal EFI Shell  
Figure 29. Setup Utility – Delete Boot Option Screen Display  
Table 25. Setup Utility – Delete Boot Option Fields  
Setup Item  
Options  
Help Text  
60  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Setup Item  
BIOS User Interface  
Options  
Help Text  
Delete Boot Option  
Remove an EFI boot option from the  
boot order.  
Select one to Delete  
Internal EFI Shell  
5.3.2.6.2  
Hard Disk Order Screen  
The Hard Disk Order screen allows the user to control the hard disks.  
To access this screen from the Main screen, choose Boot Options > Hard Disk Order.  
Boot Options  
Hard Disk #1  
Hard Disk #2  
< Available Hard Disks >  
< Available Hard Disks >  
Figure 30. Setup Utility — Hard Disk Order Screen Display  
Table 26. Setup Utility — Hard Disk Order Fields  
Setup Item  
Options  
Available  
Legacy devices  
for this Device  
group.  
Help Text  
Comments  
Hard Disk #1  
Set system boot order by selecting the boot  
option for this position.  
Hard Disk #2  
Available  
Set system boot order by selecting the boot  
option for this position.  
Legacy devices  
for this Device  
group.  
5.3.2.6.3  
CDROM Order Screen  
The CDROM Order screen allows the user to control the CDROM devices.  
To access this screen from the Main screen, select Boot Options > CDROM Order.  
Boot Options  
<Available CDROM devices>  
<Available CDROM devices>  
CDROM #1  
CDROM #2  
Figure 31. Setup Utility – CDROM Order Screen Display  
Table 27. Setup Utility – CDROM Order Fields  
Revision 1.0  
61  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Help Text  
Setup Item  
Options  
Available  
CDROM #1  
Set system boot order by selecting the boot  
Legacy devices  
for this Device  
group.  
option for this position.  
CDROM #2  
Available  
Set system boot order by selecting the boot  
option for this position.  
Legacy devices  
for this Device  
group.  
5.3.2.6.4  
Floppy Order Screen  
The Floppy Order screen allows the user to control the floppy drives.  
To access this screen from the Main screen, choose Boot Options > Floppy Order.  
Boot Options  
<Available Floppy Disk >  
<Available Floppy Disk >  
Floppy Disk #1  
Floppy Disk #2  
Figure 32. Setup Utility — Floppy Order Screen Display  
Table 28. Setup Utility — Floppy Order Fields  
Setup Item  
Options  
Available  
Legacy devices  
for this Device  
group.  
Help Text  
Floppy Disk #1  
Set system boot order by selecting the boot  
option for this position.  
Floppy Disk #2  
Available  
Set system boot order by selecting the boot  
option for this position.  
Legacy devices  
for this Device  
group.  
5.3.2.6.5  
Network Device Order Screen  
The Network Device Order screen allows the user to control the network bootable devices.  
To access this screen from the Main screen, select Boot Options > Network Device Order.  
Boot Options  
<Available Network devices>  
<Available Network devices>  
Network Device #1  
Network Device #2  
Figure 33. Setup Utility – Network Device Order Screen Display  
62  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
BIOS User Interface  
Table 29. Setup Utility – Network Device Order Fields  
Setup Item  
Options  
Available  
Legacy devices  
for this Device  
group.  
Help Text  
Network Device #1  
Set system boot order by selecting the boot  
option for this position.  
Network Device #2  
Available  
Set system boot order by selecting the boot  
option for this position.  
Legacy devices  
for this Device  
group.  
5.3.2.7  
Boot Manager Screen  
The Boot Manager screen allows the user to view a list of devices available for booting, and to  
select a boot device for immediately booting the system.  
To access this screen from the Main screen, select Boot Manager.  
Advance  
Main  
Security  
Server Management  
Boot Options  
Boot Manager  
d
[Internal EFI Shell]  
<Boot device #1>  
<Boot Option #x>  
Figure 34. Setup Utility – Boot Manager Screen Display  
Table 30. Setup Utility – Boot Manager Screen Fields  
Setup Item  
Help Text  
Select this option to boot now.  
Internal EFI Shell  
Note: This list is not the system boot option order. Use the  
Boot Options menu to view and configure the system boot  
option order.  
Boot Device #x  
Select this option to boot now.  
Note: This list is not the system boot option order. Use the  
Boot Options menu to view and configure the system boot  
option order.  
5.4 Loading BIOS Defaults  
Different mechanisms exist for resetting the system configuration to the default values. When a  
request to reset the system configuration is detected, the BIOS loads the default system  
configuration values during the next POST. You can send the request to reset the system to the  
defaults in the following ways:  
Pressing <F9> from within the BIOS Setup utility.  
Revision 1.0  
63  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BIOS User Interface  
IntelP®P Server Board S3420GP TPS  
Moving the clear system configuration jumper.  
IPMI command (set System Boot options command)  
Int15 AX=DA209  
Choosing Load User Defaults from the Exit page of the BIOS Setup loads user set defaults instead of  
the BIOS factory defaults.  
The recommended steps to load the BIOS defaults are:  
1. Power down the system (Do not remove AC power).  
2. Move the Clear CMOS jumper from pins 1-2 to pins 2-3.  
3. Move the Clear CMOS jumper from pins 2-3 to pins 1-2.  
4. Power up the system.  
64  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Connector/Header Locations and Pin-outs  
6. Connector / Header Locations and Pin-outs  
6.1 Board Connector Information  
The following section provides detailed information regarding all connectors, headers, and  
jumpers on the server board. It lists all connector types available on the board and the  
corresponding reference designators printed on the silkscreen.  
Table 31. Board Connector Matrix  
Connector  
Quantity  
Reference Designators  
J9A1, J9C1, J9J1  
Connector Type  
Pin  
Count  
Power supply  
3
Main power  
CPU power  
P/S aux  
24  
8
5
CPU  
1
6
J6G1  
CPU sockets  
DIMM sockets  
1156  
240  
Main memory  
J8J3, J8J2, J8J1, J9J3, J9J2, J8J4  
Intel® RMM3  
SAS Module  
CPU Fan  
1
1
1
4
1
2
1
1
1
1
1
2
J2C1  
Header  
34  
?
J2H1  
Header  
J6E1  
Header  
4
System Fans  
Battery  
J1J4, J6J2, J7J1, J6B1  
BT5C1  
Header  
4
Battery holder  
Dual USB  
External DSub  
Connector  
Header  
3
NIC/Stack 2x USB  
Video  
J5A1, J6A1  
J7A1  
8
15  
9
Serial port A  
Serial port B  
Front panel  
USB floopy  
J8A1  
J1B2  
9
J4H3  
Header  
24  
4
J1C1  
Header  
Dual- USB Internal  
Header  
J1D1, J1E1  
Header  
10  
PCI-E x16  
PCI-E x8  
1
3
1
1
1
1
6
1
1
1
1
J4B3  
Card Edge  
Card Edge  
Card Edge  
Card Edge  
Connector  
Header  
164  
98  
64  
120  
60  
2
J2B2, J3B1, J4B2  
PCI-E x4  
J2B1  
PCI 32  
J1B1  
XDP Connector  
Chassis Intrusion  
Serial ATA  
IPMB  
J5J1  
J1J1  
J1H4, J1H1, J1G1, J1H3, J1G3, J1F4  
Header  
7
J1H2  
J1J1  
J3F2  
J1J3  
Header  
4
HSBP  
Header  
4
Z-U130 USB  
SATA_SGPIO  
Header  
10  
4
Header  
6.2 Power Connectors  
The main power supply connection uses an SSI-compliant 2x12 pin connector (J9A1). In  
addition, there is one additional power related connector:  
Revision 1.0  
65  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector/Header Locations and Pin-outs  
IntelP®P Server Board S3420GP TPS  
ƒ
One SSI-compliant 2x4 pin power connector (J9C1), which provides 12-V power to the  
CPU VRD.  
The following tables define the connector pin-outs.  
Table 32. Baseboard Power Connector Pin-out (J9A1)  
Pin  
Signal  
+3.3 Vdc  
+3.3 Vdc  
GND  
Color  
Orange  
Orange  
Black  
Red  
Pin  
13  
Signal  
+3.3 Vdc  
-12 Vdc  
GND  
Color  
Orange  
Blue  
1
2
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
3
Black  
Green  
Black  
Black  
Black  
White  
Red  
4
+5 Vdc  
GND  
PS_ON#  
GND  
5
Black  
Red  
6
+5 Vdc  
GND  
GND  
7
Black  
GND  
8
PWRGD_PS Gray  
NC  
9
5 VSB  
Purple  
+5 Vdc  
+5 Vdc  
+5 Vdc  
GND  
10  
11  
12  
+12 Vdc  
+12 Vdc  
+3.3 Vdc  
Yellow  
Yellow  
Orange  
Red  
Red  
Black  
Table 33. SSI Processor Power Connector Pin-out (J9C1)  
Pin  
Signal  
GND  
Color  
Black  
1
2
3
4
5
6
7
8
GND  
Black  
GND  
Black  
GND  
Black  
+12 Vdc  
+12 Vdc  
+12 Vdc  
+12 Vdc  
Yellow / black  
Yellow / black  
Yellow / black  
Yellow / black  
6.3 System Management Headers  
6.3.1  
Intel® Remote Management Module 3 (Intel® RMM3) Connector  
A 34-pin Intel® RMM 3 connector (J2C1) is included on the server board to support the optional  
Intel® Remote Management Module 3. This server board does not support third-party  
management cards.  
Note: This connector is not compatible with the Intel® Remote Management Module (Intel®  
RMM) or the Intel® Remote Management Module 2 (Intel® RMM2).  
Table 34. Intel® RMM3 Connector Pin-out (J2C1)  
66  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Connector/Header Locations and Pin-outs  
Pin  
Signal Name  
P3V3_AUX  
Pin  
Signal Name  
RMII_IBMC_RMM3_MDIO  
RMII_IBMC_RMM3_MDC  
RMII_IBMC_RMM3_RXD1  
RMII_IBMC_RMM3_RXD0  
RMII_IBMC_RMM3_CRS_DV  
CLK_50M_RMM3  
1
3
5
7
9
2
4
6
8
P3V3_AUX  
GND  
GND  
GND  
10  
12  
14  
16  
18  
20  
22  
24  
11  
13  
15  
17  
19  
21  
23  
GND  
GND  
RMII_IBMC_RMM3_RX_ER  
RMII_IBMC_RMM3_TX_EN  
KEY  
GND  
GND  
GND  
RMII_IBMC_RMM3_TXD0  
RMII_IBMC_RMM3_TXD1  
SPI_IBMC_BK_CS_N  
GND  
P3V3_AUX  
25  
27  
29  
31  
33  
P3V3_AUX  
P3V3_AUX  
GND  
26  
28  
30  
32  
34  
TP_RMM3_SPI_WE  
SPI_IBMC_BK_DO  
SPI_IBMC_BK_CLK  
SPI_IBMC_BK_DI  
GND  
GND  
FM_RMM3_Present_N  
6.3.2  
LCP / IPMB Header  
Table 35. LPC / IPMB Header Pin-out (J1H2)  
Pin  
Signal Name  
Description  
1
SMB_IPMB_5VSB_DAT  
Integrated BMC IMB 5V standby  
data line  
2
3
GND  
Ground  
SMB_IPMB_5VSB_CLK  
Integrated BMC IMB 5V standby  
clock line  
4
P5V_STBY  
+5 V standby power  
6.3.3  
HSBP Header  
Table 36. HSBP Header Pin-out (J1J1)  
Pin  
1
Signal Name  
SMB_HSBP_5V_DAT  
GND  
2
3
4
SMB_HSBP_5V_CLK  
FM_HSBP_ADD_C2  
6.3.4  
SGPIO Header  
Table 37. SGPIO Header Pin-out (J1J3)  
Pin  
Signal Name  
Description  
1
SGPIO_CLOCK  
SGPIO Clock Signal  
Revision 1.0  
67  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector/Header Locations and Pin-outs  
IntelP®P Server Board S3420GP TPS  
2
3
4
SGPIO_LOAD  
SGPIO Load Signal  
SGPIO_DATAOUT0  
SGPIO_DATAOUT1  
SGPIO Data Out  
SGPIO Data In  
6.4 Front Control Panel Connector  
The server board provides a 24-pin SSI front panel connector (J1C1) for use with Intel® and  
third-party chassis. The following table provides the pin-out for this connector.  
Table 38. Front Panel SSI Standard 24-pin Connector Pin-out (J1C1)  
Pin  
Signal Name  
P3V3_AUX  
Pin  
Signal Name  
1
3
5
7
9
2
4
6
8
P3V3_AUX  
P5V_STBY  
Key  
FP_PWR_LED_N  
P3V3  
FP_ID_LED_N  
LED_GREEN_R_N  
LED_AMBER_R_N  
LED_NIC1_ACT_R  
LED_NIC1_LINK_FP_N  
SMB_SENS_DAT  
SMB_SENSOR_CLK  
INTRU_HDR_N  
LED_HDD_ACTIVITY_N  
FP_PWR_BTN_N  
GND  
10  
12  
14  
16  
18  
20  
11  
13  
15  
17  
19  
21  
23  
RST_FP_BTN_N  
GND  
FP_ID_BTN_N  
PU_FM_SIO_TEMP_SENSOR 22  
FP_NMI_BTN_N 24  
LED_NIC2_ACT_R  
LED_NIC2_LINK_FP_N  
Combined system BIOS and the Integrated BMC support provide the functionality of the various  
supported control panel buttons and LEDs. The following sections describe the supported  
functionality of each control panel feature.  
Note: Control panel features are also routed through the bridge board connector at location  
J1C1 as is implemented in Intel® Server Systems configured using a bridge board and a hot-  
swap backplane.  
6.4.1  
Power Button  
The BIOS supports a front control panel power button. Pressing the power button initiates a  
request that the Integrated BMC forwards to the ACPI power state machines in the chipset. It is  
monitored by the Integrated BMC and does not directly control power on the power supply.  
ƒ
Power Button — Off to On  
The Integrated BMC monitors the power button and the wake-up event signals from the  
chipset. A transition from either source results in the Integrated BMC starting the power-  
up sequence. Since the processor are not executing, the BIOS does not participate in  
this sequence. The hardware receives the power good and reset signals from the  
Integrated BMC and then transitions to an ON state.  
ƒ
Power Button — On to Off (Operating system absent)  
The System Control Interrupt (SCI) is masked. The BIOS sets up the power button event  
to generate an SMI and checks the power button status bit in the ACPI hardware  
registers when an SMI occurs. If the status bit is set, the BIOS sets the ACPI power  
state of the machine in the chipset to the OFF state. The Integrated BMC monitors  
68  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Connector/Header Locations and Pin-outs  
power state signals from the chipset and de-asserts PS_PWR_ON to the power supply.  
As a safety mechanism, if the BIOS fails to service the request, the Integrated BMC  
automatically powers off the system in 4 to 5 seconds.  
ƒ
Power Button — On to Off (Operating system present)  
If an ACPI operating system is running, pressing the power button switch generates a  
request using SCI to the operating system to shut down the system. The operating  
system retains control of the system and the operating system policy determines the  
sleep state into which the system transitions, if any. Otherwise, the BIOS turns off the  
system.  
6.4.2  
Reset Button  
The platform supports a front control panel reset button. Pressing the reset button initiates a  
request forwarded by the Integrated BMC to the chipset. The BIOS does not affect the behavior  
of the reset button.  
6.4.3  
NMI Button  
The Intel® S3420GP Server Board family BIOS does not support the NMI button.  
6.4.4  
System Status Indicator LED  
The Intel® Server Board S3420GP that uses the Intel® Xeon® 3400 Series processor has a  
system status indicator LED on the front panel. This indicator LED has specific states and  
corresponding interpretation as shown in the following table.  
Revision 1.0  
69  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector/Header Locations and Pin-outs  
IntelP®P Server Board S3420GP TPS  
Table 39. System Status LED Indicator States  
Color  
Green  
Green  
State  
Solid on  
~1 Hz blink  
Criticality  
Ok  
Degraded  
Description  
System booted and ready  
System degraded:  
ƒ
ƒ
ƒ
ƒ
Non-critical temperature threshold asserted.  
Non-critical voltage threshold asserted.  
Non-critical fan threshold asserted.  
Fan redundancy lost, sufficient system cooling maintained.  
This does not apply to non-redundant systems.  
ƒ
ƒ
Power supply predictive failure.  
Power supply redundancy lost. This does not apply to non-  
redundant systems.  
ƒ
Correctable errors over a threshold of 10 and migrating to a  
spare DIMM (memory sparing). This indicates the user no  
longer has spared DIMMs indicating a redundancy lost  
condition. Corresponding DIMM LED should light up.1  
Amber  
~1 Hz blink  
Non-critical  
Non-fatal alarm – system is likely to fail:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
CATERR asserted.  
Critical temperature threshold asserted.  
Critical voltage threshold asserted.  
Critical fan threshold asserted.  
VRD hot asserted.  
SMI Timeout asserted.  
Amber  
Solid on  
Critical, non-  
recoverable  
Fatal alarm – system has failed or shutdown:  
ƒ
ƒ
ƒ
ƒ
ƒ
Thermtrip asserted.  
Non-recoverable temperature threshold asserted.  
Non-recoverable voltage threshold asserted.  
Power fault / Power Control Failure.  
Fan redundancy lost, insufficient system cooling. This does  
not apply to non-redundant systems.  
Off  
N/A  
Not ready  
AC power off, if no degraded, non-critical, critical, or non-recoverable  
conditions exist.  
Notes:  
1. The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to provide  
the contribution to the system status LED.  
2. Support for upper non-critical limit is not provided in the default SDR configuration. However, if a user does  
enable this threshold in the SDR, then the system status LED should behave as described.  
There is no precedence or lock-out mechanism for the control sources. When a new request  
arrives, all previous requests are terminated. For example, if the chassis ID LED is blinking and  
the chassis ID button is pressed, then the chassis ID LED changes to solid on. If the button is  
pressed again with no intervening commands, the chassis ID LED turns off.  
70  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Connector/Header Locations and Pin-outs  
6.5 I/O Connectors  
6.5.1  
VGA Connector  
The following table details the pin-out definition of the VGA connector (J7A1).  
Table 40. VGA Connector Pin-out (J7A1)  
Pin  
Signal Name  
V_IO_R_CONN  
Description  
Red (analog color signal R)  
Green (analog color signal G)  
Blue (analog color signal B)  
No connection  
1
2
3
4
5
6
7
8
9
V_IO_G_CONN  
V_IO_B_CONN  
TP_VID_CONN_B4  
GND  
Ground  
GND  
Ground  
GND  
Ground  
GND  
Ground  
TP_VID_CONN_B9  
GND  
No connection  
10  
11  
12  
13  
14  
15  
Ground  
TP_VID_CONN_B11  
V_IO_DDCDAT  
V_IO_HSYNC_CONN  
V_IO_VSYNC_CONN  
V_IO_DDCCLK  
No connection  
DDCDAT  
HSYNC (horizontal sync)  
VSYNC (vertical sync)  
DDCCLK  
6.5.2  
Rear NIC and USB connector  
The server board provides two stacked RJ-45 / 2xUSB connectors side-by-side on the back  
edge of the board (J6A1, J5A1). The pin-out for NIC connectors are identical and defined in the  
following table.  
Table 41. RJ-45 10/100/1000 NIC Connector Pin-out (J5A1)  
Pin  
Signal Name  
P5V_USB_PWR75  
Pin  
Signal Name  
USB_PCH_11_FB_DN  
GND  
1
2
4
6
8
3
USB_PCH_11_FB_DP  
P5V_USB_PWR75  
USB_PCH_10_FB_DP  
P1V9_LAN2_R  
5
USB_PCH_10_FB_DN  
GND  
7
9
10  
12  
14  
NIC2_MDIP<0>  
NIC2_MDIP<1>  
11  
13  
NIC2_MDIN<0>  
NIC2_MDIN<1>  
NIC2_MDIP<2>  
NIC2_MDIP<3>  
GND  
15  
17  
16  
18  
NIC2_MDIN<2>  
NIC2_MDIN<3>  
19  
21  
LED_NIC2_1  
20  
22  
P3V3_AUX  
LED_NIC2_LINK100_R_0  
LED_NIC2_LINK1000_2  
Table 42. RJ-45 10/100/1000 NIC Connector Pin-out (J6A1)  
Revision 1.0  
71  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector/Header Locations and Pin-outs  
IntelP®P Server Board S3420GP TPS  
Pin  
Signal Name  
P5V_USB_PWR75  
Pin  
Signal Name  
USB_PCH_11_FB_DN  
GND  
1
2
4
6
8
3
USB_PCH_11_FB_DP  
P5V_USB_PWR75  
USB_PCH_10_FB_DP  
P1V8_PHY_VCT_R  
NIC1_MDIN<0>  
5
USB_PCH_10_FB_DN  
GND  
7
9
10  
12  
14  
16  
NIC1_MDIP<0>  
NIC1_MDIP<1>  
NIC2_MDIP<2>  
11  
13  
15  
NIC1_MDIN<1>  
NIC1_MDIN<2>  
NIC2_MDIP<3>  
17  
18  
GND  
NIC1_MDIN<3>  
19  
21  
LED_NIC1_LINK_ACT_0_R  
LED_NIC1_2  
20  
22  
P3V3_AUX  
LED_NIC1_LINK1000_1  
6.5.3  
SATA  
The sever board provides up to six SATA connectors. The pin configuration for each connector  
is identical and defined in the following table.  
Table 43. SATA Connector Pin-out (J1H4, J1H1, J1G1, J1H3, J1G3, J1F4)  
Pin  
Signal Name  
Description  
1
2
3
4
5
6
7
GND  
Ground  
SATA/SAS_TX_P_C  
SATA/SAS_TX_N_C  
GND  
Positive side of transmit differential pair  
Negative side of transmit differential pair  
Ground  
SATA/SAS_RX_N_C  
SATA/SAS_RX_P_C  
GND  
Negative side of receive differential pair  
Positive side of receive differential pair  
Ground  
6.5.4  
SAS Connectors  
The Intel® Server Board S3420GPLX provides one SAS connector.  
The pin configuration is identical and defined in the following table.  
Table 44. SAS Connector Pin-out (J2H1)  
Pin  
Signal Name  
Description  
1
2
3
4
5
6
7
GND  
Ground  
SATA/SAS_TX_P_C  
SATA/SAS_TX_N_C  
GND  
Positive side of transmit differential pair  
Negative side of transmit differential pair  
Ground  
SATA/SAS_RX_N_C  
SATA/SAS_RX_P_C  
GND  
Negative side of receive differential pair  
Positive side of receive differential pair  
Ground  
6.5.5  
Serial Port Connectors  
The server board provides one external DB9 Serial A port (J8A1) and one internal 9-pin serial B  
header (J1B2). The following tables define the pin-outs.  
72  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Connector/Header Locations and Pin-outs  
Table 45. External Serial A Port Pin-out (J8A1)  
Pin  
Signal Name  
SPA_DCD  
SPA_SIN_L  
SPA_SOUT_N  
SPA_DTR  
GND  
Description  
DCD (carrier detect)  
1
2
3
4
5
6
7
8
9
RXD (receive data)  
TXD (Transmit data)  
DTR (Data terminal ready)  
Ground  
SPA_DSR  
SPA_RTS  
SPA_CTS  
SPA_RI  
DSR (data set ready)  
RTS (request to send)  
CTS (clear to send)  
RI (Ring Indicate)  
10  
NC  
Table 46. Internal 9-pin Serial B Header Pin-out (J1B2)  
Pin  
Signal Name  
SPB_DCD  
SPB_DSR  
SPB_SIN_L  
SPB_RTS  
SPB_SOUT_N  
SPB_CTS  
SPB_DTR  
SPB_RI  
Description  
DCD (carrier detect)  
DSR (data set ready)  
RXD (receive data)  
RTS (request to send)  
TXD (Transmit data)  
CTS (clear to send)  
DTR (Data terminal ready)  
RI (Ring indicate)  
1
2
3
4
5
6
7
8
9
SPB_EN_N  
NC  
Enable  
10  
6.5.6  
USB Connector  
There are four external USB ports on two NIC/USB combination. Section 5.5.2 details the pin-  
out of the connector.  
Two 2x5 connector on the server board (J1E1, J1D1) provides an option to support an  
additional USB port, each connector supporting two USB ports. The following table defines the  
pin-out of the connector.  
Revision 1.0  
73  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector/Header Locations and Pin-outs  
IntelP®P Server Board S3420GP TPS  
Table 47. Internal USB Connector Pin-out ( J1E1, J1D1)  
Pin  
Signal Name  
USB2_VBUS4  
Description  
1
USB power (port 4)  
2
USB2_VBUS5  
USB power (port 5)  
3
USB_ICH_P4N_CONN  
USB_ICH_P5N_CONN  
USB_ICH_P4P_CONN  
USB_ICH_P5P_CONN  
Ground  
USB port 4 negative signal  
USB port 5 negative signal  
USB port 4 positive signal  
USB port 5 positive signal  
4
5
6
7
8
Ground  
9
Key  
No pin  
10  
TP_USB_ICH_NC  
Test point  
One x connector (J1J2) on the server board provides an option to support a USB floppy  
connector.  
Table 48. Pin-out of Internal USB Connector for Floppy ( J1J2)  
Pin  
Signal Name  
+5V  
1
2
3
4
USB_N  
USB_P  
GND  
One 2x5 connectors (J3F2) on the server board provides an option to support an Intel® Z-U130  
Value Solid State Drive. The following table defines the pin-out of the connector.  
Table 49. Pin-out of Internal USB Connector for low-profile Intel® Z-U130 Value Solid State Drive  
(J3F2)  
Pin  
Signal Name  
Description  
USB power  
1
+5V  
NC  
2
N/A  
3
USB Data -  
NC  
USB port ## negative signal  
4
N/A  
5
USB Data +  
NC  
USB port ## positive signal  
6
N/A  
7
Ground  
NC  
N/A  
8
N/A  
9
Key  
No pin  
Activity LED  
10  
LED#  
74  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Connector/Header Locations and Pin-outs  
6.6 PCI Express* Slot / PCI Slot / Riser Card Slot /  
A PCI-E Riser card will enable a PCI-E add-on card to be accommodated in the 1U chassis.  
The following table shows the pin-out for this riser slot.  
Table 50. Pin-out of adaptive riser slot / PCI Express slot 6  
Pin  
B1  
Signal  
+12V  
Description  
P12V  
Pin  
A1  
Signal  
PRSNT1_N  
+12V  
Description  
GND  
B2  
+12V  
P12V  
A2  
P12V  
B3  
RSVD  
P12V  
A3  
+12V  
P12V  
B4  
GND  
GND  
A4  
GND  
GND  
B5  
SMCLK  
SMDATA  
GND  
PU_S6_SMBCLK  
PU_S6_SMBDAT  
GND  
A5  
JTAG2  
JTAG3  
JTAG4  
JTAG5  
+3_3V  
P3V3_RISER_A5  
JTAG_S6_TDI  
NC  
B6  
A6  
B7  
A7  
B8  
+3.3V  
P3V3  
A8  
P3V3_RISER_A8  
P3V3  
B9  
JTAG1  
+3.3VAUX  
WAKE_N  
JTAG_S6_TRST_N  
P3V3_AUX  
FM_PE_WAKE_N  
A9  
B10  
B11  
A10  
A11  
+3_3V  
P3V3  
PERST_N  
RST_PE_S236_N_R1  
KEY  
KEY  
KEY  
KEY  
B12  
B13  
B14  
B15  
B16  
B17  
B18  
B19  
B20  
B21  
B22  
B23  
B24  
B25  
B26  
B27  
B28  
B29  
B30  
B31  
B32  
RSVD  
GND  
NC  
A12  
A13  
A14  
A15  
A16  
A17  
A18  
A19  
A20  
A21  
A22  
A23  
A24  
A25  
A26  
A27  
A28  
A29  
A30  
A31  
A32  
GND  
REFCLKP  
REFCLKN  
GND  
GND  
GND  
CLK_100M_SLOT6A_DP  
PETP0  
PETN0  
GND  
P2E_CPU_C_S6_TXP<7>  
CLK_100M_SLOT6A_DPN  
P2E_CPU_C_S6_TXN<7>  
GND  
GND  
PERP0  
PERN0  
GND  
P2E_CPU_S6_RXP<7>  
PRSNT2_N  
GND  
NC  
P2E_CPU_S6_RXN<7>  
GND  
GND  
PETP1  
PETN1  
GND  
P2E_CPU_C_S6_TXP<6>  
RSVD  
GND  
NC  
P2E_CPU_C_S6_TXN<6>  
GND  
P2E_CPU_S6_RXP<6>  
P2E_CPU_S6_RXN<6>  
GND  
GND  
PERP1  
PERN1  
GND  
GND  
GND  
PETP2  
PETN2  
GND  
P2E_CPU_C_S6_TXP<5>  
P2E_CPU_C_S6_TXN<5>  
GND  
GND  
GND  
PERP2  
PERN2  
GND  
P2E_CPU_S6_RXP<5>  
P2E_CPU_S6_RXN<5>  
GND  
GND  
GND  
PETP3  
PETN3  
GND  
P2E_CPU_C_S6_TXP<4>  
P2E_CPU_C_S6_TXN<4>  
GND  
GND  
GND  
NC  
PERP3  
PERN3  
GND  
P2E_CPU_S6_RXP<4>  
P2E_CPU_S6_RXN<4>  
GND  
RSVD  
PRSNT2_N  
GND  
NC  
GND  
RSVD  
NC  
End of x4  
End of x4  
B33  
B34  
B35  
B36  
B37  
B38  
PETP4  
PETN4  
GND  
P2E_CPU_C_S6_TXP<3>  
P2E_CPU_C_S6_TXN<3>  
GND  
A33  
A34  
A35  
A36  
A37  
A38  
RSVD  
GND  
NC  
GND  
P2E_CPU_S6_RXN<3>  
P2E_CPU_S6_RXP<3>  
GND  
PERP4  
PERN4  
GND  
GND  
GND  
PETP5  
PETN5  
P2E_CPU_C_S6_TXP<2>  
P2E_CPU_C_S6_TXN<2>  
GND  
GND  
Revision 1.0  
75  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector/Header Locations and Pin-outs  
IntelP®P Server Board S3420GP TPS  
B39  
B40  
B41  
B42  
B43  
B44  
B45  
B46  
B47  
B48  
B49  
GND  
GND  
GND  
A39  
A40  
A41  
A42  
A43  
A44  
A45  
A46  
A47  
A48  
A49  
PERP5  
P2E_CPU_S6_RXN<2>  
P2E_CPU_S6_RXP<2>  
GND  
GND  
PERN5  
GND  
PETP6  
PETN6  
GND  
P2E_CPU_C_S6_TXP<1>  
P2E_CPU_C_S6_TXN<1>  
GND  
GND  
GND  
PERP6  
PERN6  
GND  
P2E_CPU_S6_RXN<1>  
P2E_CPU_S6_RXP<1>  
GND  
GND  
GND  
PETP7  
PETN7  
GND  
P2E_CPU_C_S6_TXP<0>  
P2E_CPU_C_S6_TXN<0>  
GND  
GND  
GND  
NC  
PERP7  
PERN7  
GND  
P2E_CPU_S6_RXN<0>  
P2E_CPU_S6_RXP<0>  
GND  
PRSNT2_N  
GND  
GND  
End of x8  
End of x8  
B50  
B51  
B52  
B53  
B54  
B55  
B56  
B57  
B58  
B59  
B60  
B61  
B62  
B63  
B64  
B65  
B66  
B67  
B68  
B69  
B70  
B71  
B72  
B73  
B74  
B75  
B76  
B77  
B78  
B79  
B80  
B81  
B82  
PETP8  
PETN8  
GND  
NC  
NC  
A50  
A51  
A52  
A53  
A54  
A55  
A56  
A57  
A58  
A59  
A60  
A61  
A62  
A63  
A64  
A65  
A66  
A67  
A68  
A69  
A70  
A71  
A72  
A73  
A74  
A75  
A76  
A77  
A78  
A79  
A80  
A81  
A82  
RSVD  
GND  
NC  
GND  
NC  
GND  
GND  
NC  
PERP8  
PERN8  
GND  
GND  
NC  
PETP9  
PETN9  
GND  
GND  
GND  
NC  
NC  
GND  
GND  
GND  
NC  
PERP9  
PERN9  
GND  
GND  
NC  
PETP10  
PETN10  
GND  
GND  
GND  
NC  
NC  
GND  
GND  
GND  
NC  
PERP10  
PERN10  
GND  
GND  
NC  
PExP11  
PETN11  
GND  
GND  
GND  
NC  
NC  
GND  
GND  
GND  
NC  
PERP11  
PERN11  
GND  
GND  
NC  
PETP12  
PETN12  
GND  
GND  
GND  
NC  
NC  
GND  
GND  
GND  
NC  
PERP12  
PERN12  
GND  
GND  
NC  
PETP13  
PETN13  
GND  
GND  
GND  
NC  
NC  
GND  
GND  
GND  
NC  
PERP13  
PERN13  
GND  
GND  
NC  
PETP14  
PETN14  
GND  
GND  
GND  
NC  
NC  
GND  
GND  
GND  
NC  
PERP14  
PERN14  
GND  
GND  
NC  
PETP15  
PETN15  
GND  
GND  
GND  
NC  
NC  
GND  
GND  
NC  
PERP15  
PERN15  
GND  
PRSNT2_N  
RSVD  
NC  
GND  
NC  
76  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Connector/Header Locations and Pin-outs  
Three PCI Express* x8 connectors (J2B2, J3B1 and J4B2)  
Pin  
Signal  
PRSNT1#  
+12V  
Pin  
Signal  
Pin  
A26  
A27  
A28  
A29  
A30  
A31  
A32  
A33  
A34  
A35  
A36  
A37  
A38  
A39  
A40  
A41  
A42  
A43  
A44  
A45  
A46  
A47  
A48  
A49  
Signal  
HSIP[2]  
GND  
Pin  
B26  
B27  
B28  
B29  
B30  
B31  
B32  
B33  
B34  
B35  
B36  
B37  
B38  
B39  
B40  
B41  
B42  
B43  
B44  
B45  
B46  
B47  
B48  
B49  
Signal  
GND  
A1  
B1  
+12V  
A2  
B2  
+12V  
HSOP[3]  
HSON[3]  
GND  
A3  
+12V  
B3  
RESERVED  
GND  
GND  
HSIP[3]  
A4  
GND  
B4  
HSIN[3]  
A5  
JTAG2/TCk  
JTAG3/TDI  
JTAG4/TDO  
JTAG5/TMS  
+3.3V  
B5  
SMCLK  
SMDAT  
GND  
RESERVED  
PRSNT2#  
GND  
A6  
B6  
GND  
A7  
B7  
RESERVED  
RESERVED  
A8  
B8  
+3.3V  
HSOP[4]  
HSON[4]  
GND  
A9  
B9  
JTAG1/TRST#  
3.3VAUX  
WAKE#  
RESERVED  
GND  
GND  
HSIP[4]  
A10  
A11  
A12  
A13  
A14  
A15  
A16  
A17  
A18  
A19  
A20  
A21  
A22  
A23  
A24  
A25  
+3.3V  
B10  
B11  
B12  
B13  
B14  
B15  
B16  
B17  
B18  
B19  
B20  
B21  
B22  
B23  
B24  
B25  
HSIN[4]  
GND  
PERST#  
GND  
GND  
HSOP[5]  
HSON[5]  
GND  
REFCLK+  
REFCLK-  
GND  
GND  
HSIP[5]  
HSOP[0]  
HSON[0]  
GND  
HSIN[5]  
GND  
GND  
HSIP[0]  
HSIN[0]  
GND  
HSOP[6]  
HSON[6]  
GND  
PRSNT2#  
GND  
GND  
HSIP[6]  
HSIN[6]  
GND  
RESERVED  
GND  
HSOP[1]  
HSON[1]  
GND  
GND  
HSOP[7]  
HSON[7]  
GND  
HSIP[1]  
HSIN[1]  
GND  
GND  
HSIP[7]  
GND  
HSIN[7]  
GND  
HSOP[2]  
HSON[2]  
GND  
PRSNT2#  
GND  
GND  
HSIP[2]  
One PCI Express* X4 connector (J2B1)  
Pin#  
A1  
Signal  
PRSNT1_N  
+12V  
Pin#  
B1  
Signal  
+12V  
+12V  
RSVD  
GND  
Pin#  
A17  
A18  
A19  
A20  
Signal  
PERN0  
GND  
Pin#  
B17  
B18  
B19  
B20  
Signal  
PRSNT2_N  
GND  
A2  
B2  
A3  
+12V  
B3  
RSVD  
GND  
PETP1  
A4  
GND  
B4  
PETN1  
Revision 1.0  
77  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector/Header Locations and Pin-outs  
IntelP®P Server Board S3420GP TPS  
Pin#  
A5  
Signal  
JTAG2  
JTAG3  
JTAG4  
JTAG5  
+3.3V  
Pin#  
B5  
Signal  
SMCLK  
SMDAT  
GND  
Pin#  
A21  
A22  
A23  
A24  
A25  
A26  
A27  
A28  
A29  
A30  
A31  
A32  
Signal  
PERP1  
PERN1  
GND  
Pin#  
B21  
B22  
B23  
B24  
B25  
B26  
B27  
B28  
B29  
B30  
B31  
B32  
Signal  
GND  
A6  
B6  
GND  
A7  
B7  
PETP2  
PETN2  
GND  
A8  
B8  
+3.3V  
GND  
A9  
B9  
JTAG1  
3.3VAUX  
WAKE_N  
RSVD  
PERP2  
PERN2  
GND  
A10  
A11  
A12  
A13  
A14  
A15  
A16  
+3.3V  
B10  
B11  
B12  
B13  
B14  
B15  
B16  
GND  
PERST_N  
GND  
PETP3  
PETN3  
GND  
GND  
REFCLK+  
REFCLK-  
GND  
GND  
PERP3  
PERN3  
GND  
PETP0  
PETN0  
GND  
RSVD  
PRSNT2_N  
GND  
PERP0  
RSVD  
One PCI X32 connector (J1B1)  
Pin #  
Signal  
Pin #  
Signal  
Pin #  
Signal  
Pin #  
Signal  
B1  
-12V  
A1  
TRST#  
B32  
AD[17]  
A32  
AD[16]  
B2  
B3  
TCK  
Ground  
TDO  
A2  
A3  
+12V  
TMS  
B33  
B34  
B35  
B36  
B37  
B38  
B39  
B40  
B41  
B42  
B43  
B44  
B45  
B46  
B47  
B48  
B49  
B50  
B51  
B52  
B53  
B54  
B55  
C/BE[2]#  
Ground  
IRDY#  
+3.3V  
A33  
A34  
A35  
A36  
A37  
A38  
A39  
A40  
A41  
A42  
A43  
A44  
A45  
A46  
A47  
A48  
A49  
A50  
A51  
A52  
A53  
A54  
A55  
+3.3V  
FRAME#  
Ground  
TRDY#  
Ground  
STOP#  
+3.3V  
B4  
A4  
TDI  
B5  
+5V  
A5  
+5V  
B6  
+5V  
A6  
INTA#  
INTC#  
+5V  
DEVSEL#  
Ground  
LOCK#  
PERR#  
+3.3V  
B7  
INTB#  
INTD#  
PRSNT1#  
RSVD  
PRSNT2#  
GND  
A7  
B8  
A8  
B9  
A9  
RSVD  
V_IO  
RSVD  
RSVD  
Ground  
PAR  
B10  
B11  
B12  
B13  
B14  
B15  
B16  
B17  
B18  
B19  
B20  
B21  
B22  
B23  
B24  
A10  
A11  
A12  
A13  
A14  
A15  
A16  
A17  
A18  
A19  
A20  
A21  
A22  
A23  
A24  
RSVD  
GND  
SERR#  
+3.3V  
GND  
GND  
C/BE[1]#  
AD[14]  
Ground  
AD[12]  
AD[10]  
M66EN  
KEY  
AD[15]  
+3.3V  
RSVD  
Ground  
CLK  
3.3Vaux  
RST#  
V_IO  
AD[13]  
AD[11]  
Ground  
AD[09]  
KEY  
Ground  
REQ#  
V_IO  
GNT#  
Ground  
PME#  
AD[30]  
+3.3V  
AD[28]  
AD[26]  
Ground  
AD[31]  
AD[29]  
Ground  
AD[27]  
AD[25]  
KEY  
KEY  
AD[08]  
AD[07]  
+3.3V  
C/BE[0]#  
+3.3V  
AD[06]  
AD[04]  
AD[05]  
B25  
+3.3V  
A25  
AD[24]  
B56  
AD[03]  
A56  
Ground  
78  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Connector/Header Locations and Pin-outs  
Pin #  
Signal  
Pin #  
Signal  
Pin #  
Signal  
Pin #  
Signal  
B26  
B27  
B28  
B29  
B30  
B31  
C/BE[3]#  
AD[23]  
Ground  
AD[21]  
AD[19]  
+3.3V  
A26  
A27  
A28  
A29  
A30  
A31  
IDSEL  
+3.3V  
B57  
B58  
B59  
B60  
B61  
B62  
Ground  
AD[01]  
V_IO  
A57  
A58  
A59  
A60  
A61  
A62  
AD[02]  
AD[00]  
V_IO  
AD[22]  
AD[20]  
Ground  
AD[18]  
ACK64#  
+5V  
REQ64#  
+5V  
+5V  
+5V  
6.7 Fan Headers  
The server board provides five SSI-compliant 4-pin fan headers to be used as the CPU and  
chassis. The pin configuration for each of the 4-pin fan headers is identical and defined in the  
following table.  
ƒ
One 4-pin fan headers are designated as processor cooling fans:  
-
-
-
-
-
CPU fan (J6D1)  
SYS1 fan (J1J4)  
SYS2 fan (J6J2)  
SYS3 fan (J7J1)  
SYS4 fan (J6B1)  
Table 51. SSI 4-pin Fan Header Pin-out (J6E1, J1J4, J6J2, J7J1, J6B1)  
Pin  
Signal Name  
Ground  
Type  
GND  
Description  
Ground is the power supply ground  
1
2
3
12 V  
Power  
In  
Power supply 12 V  
Fan Tach  
FAN_TACH signal is connected to the Integrated BMC to monitor the fan  
speed  
4
Fan PWM  
Out  
FAN_PWM signal to control fan speed  
Revision 1.0  
79  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Jumper Blocks  
IntelP®P Server Board S3420GP TPS  
7. Jumper Blocks  
The server board has several 3-pin jumper blocks that can be used to configure, protect, or  
recover specific features of the server board.  
Figure 35. Jumper Blocks (J1A2, J1F1, J1F3, J1F2 and J1F5)  
Table 52. Server Board Jumpers (J1F1, J1F2, J1F3, J1F5, J1A2)  
Jumper Name  
J1F5: CMOS  
Clear  
Pins  
1-2  
System Results  
These pins should have a jumper in place for normal system operation. (Default)  
2-3  
If these pins are jumpered with AC power plugged, the CMOS settings are cleared within  
five seconds. These pins should not be jumpered for normal operation.  
J1F1: ME Force 1-2  
ME Firmware Force Update Mode – Disabled (Default)  
ME Firmware Force Update Mode – Enabled  
Update  
2-3  
J1F2:  
Password Clear  
1-2  
2-3  
These pins should have a jumper in place for normal system operation. (Default)  
If these pins are jumpered, administrator and user passwords are cleared within 5-10  
seconds after the system is powered on. These pins should not be jumpered for normal  
operation.  
J1F3: BIOS  
Recovery  
1-2  
2-3  
These pins should have a jumper in place for normal system operation. (Default)  
Given that the main system BIOS will not boot with these pins jumpered, system can only  
boot from EFI-bootable recovery media with the recovery BIOS image.  
J1A2: BMC  
1-2  
Integrated BMC Firmware Force Update Mode – Disabled (Default)  
80  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Jumper Blocks  
Jumper Name  
Pins  
System Results  
Force Update  
2-3  
Integrated BMC Firmware Force Update Mode – Enabled  
7.1 CMOS Clear and Password Reset Usage Procedure  
The CMOS Clear (J1F5) and Password Reset (J1F2) recovery features are designed such that  
the desired operation can be achieved with minimal system downtime. The usage procedure for  
these two features has changed from previous generation Intel server boards. The following  
procedure outlines the new usage model.  
7.1.1  
Clearing the CMOS  
To clear the CMOS, perform the following steps:  
1. Power down the server. Do not unplug the power cord.  
2. Open the server chassis. For instructions, see your server chassis documentation.  
3. Move jumper (J1F5) from the default operating position (covering pins 1 and 2) to the  
reset / clear position (covering pins 2 and 3).  
4. Wait five seconds.  
5. Remove AC power.  
6. Move the jumper back to the default position (covering pins 1 and 2).  
7. Close the server chassis.  
8. Power up the server.  
The CMOS is now cleared and can be reset by going into the BIOS setup.  
Note: Removing AC power before performing the CMOS clear operation causes the system to  
automatically power up and immediately power down, after the procedure is followed and AC  
power is re-applied. If this happens, remove the AC power cord again, wait 30 seconds, and re-  
install the AC power cord. Power up the system and proceed to the <F2> BIOS Setup utility to  
reset the preferred settings.  
7.1.2  
Clearing the Password  
To clear the password, perform the following steps:  
1. Power down the server. Do not unplug the power cord.  
2. Open the chassis. For instructions, see your server chassis documentation.  
3. Move jumper (J1F2) from the default operating position (covering pins 1 and 2) to the  
password clear position (covering pins 2 and 3).  
4. Close the server chassis.  
5. Power up the server and wait 10 seconds or until POST completes.  
6. Power down the server.  
Revision 1.0  
81  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Jumper Blocks  
IntelP®P Server Board S3420GP TPS  
7. Open the chassis and move the jumper back to the default position (covering pins 1 and  
2).  
8. Close the server chassis.  
9. Power up the server.  
The password is now cleared and can be reset by going into the BIOS setup.  
7.2 Integrated BMC Force Update Procedure  
When performing the standard Integrated BMC firmware update procedure, the update utility  
places the Integrated BMC into an update mode, allowing the firmware to load safely onto the  
flash device. In the unlikely event the Integrated BMC firmware update process fails due to the  
Integrated BMC not being in the proper update state, the server board provides an Integrated  
BMC Force Update jumper (J1A2), which forces the Integrated BMC into the proper update  
state. The following procedure should be completed in the event the standard Integrated BMC  
firmware update process fails.  
1. Power down and remove the AC power cord.  
2. Open the server chassis. For instructions, see your server chassis documentation.  
3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled  
position (covering pins 2 and 3).  
4. Close the server chassis.  
5. Reconnect the AC cord and power up the server.  
6. Perform the Integrated BMC firmware update procedure as documented in the  
README.TXT file that is included in the given Integrated BMC firmware update package.  
After successful completion of the firmware update process, the firmware update utility  
may generate an error stating that the Integrated BMC is still in update mode.  
7. Power down and remove the AC power cord.  
8. Open the server chassis.  
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position  
(covering pins 1 and 2).  
10. Close the server chassis.  
11. Reconnect the AC cord and power up the server.  
Note: Normal Integrated BMC functionality is disabled with the Force Integrated BMC Update  
jumper set to the enabled position. The server should never be run with the Integrated BMC  
Force Update jumper set in this position. This jumper setting should only be used when the  
standard firmware update process fails. This jumper should remain in the default / disabled  
position when the server is running normally.  
7.3 ME Force Update Jumper  
When performing the standard ME force update procedure, the update utility places the ME into  
an update mode, allowing the ME to load safely onto the flash device. In the unlikely event ME  
82  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Jumper Blocks  
firmware update process fails due to ME not being in the proper update state, the server board  
provides an Integrated BMC Force Update jumper (J1F1), which forces the ME into the proper  
update state. The following procedure should be completed in the event the standard ME  
firmware update process fails.  
1. Power down and remove the AC power cord.  
2. Open the server chassis. For instructions, see your server chassis documentation.  
3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled  
position (covering pins 2 and 3).  
4. Close the server chassis.  
5. Reconnect the AC cord and power up the server.  
6. Perform the ME firmware update procedure as documented in the README.TXT file  
that is included in the given ME firmware update package (same package as BIOS).  
7. Power down and remove the AC power cord.  
8. Open the server chassis.  
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position  
(covering pins 1 and 2).  
10. Close the server chassis.  
11. Reconnect the AC cord and power up the server.  
7.4 BIOS Recovery Jumper  
The following procedure boots the recovery BIOS and flashes the normal BIOS:  
1. Turn off the system power.  
2. Move the BIOS recovery jumper to the recovery state.  
3. Insert a bootable BIOS recovery media containing the new BIOS image files.  
4. Turn on the system power.  
The BIOS POST screen will appear displaying the progress, and the system will boot to the EFI  
shell. The EFI shell then executes the Startup.nsh batch file to start the flash update process.  
The user should then switch off the power and return the recovery jumper to its normal position.  
The user should not interrupt the BIOS POST on the first boot after recovery.  
When the flash update completes:  
1. Remove the recovery media.  
2. Turn off the system power.  
3. Restore the jumper to its original position.  
4. Turn on the system power.  
5. Re-flash any custom blocks, such as user binary or language blocks.  
The system should now boot using the updated system BIOS.  
Revision 1.0  
83  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Light Guided Diagnostics  
IntelP®P Server Board S3420GP TPS  
8. Intel® Light Guided Diagnostics  
The server board has several on-board diagnostic LEDs to assist in troubleshooting board-level  
issues. This section shows where each LED is located on the server board and describes the  
function of each LED.  
8.1 System Status LED  
The server board provides a system status indicator LED on the front panel. This indicator LED  
has specific states and corresponding interpretation as shown in the following table.  
Table 53. Front Panel Status LED Behavior Summary  
Color  
Off  
State  
N/A  
Criticality  
Not ready  
Description  
AC power off. If no degraded, non-critical, critical, or non-recoverable  
conditions exist.  
Fatal alarm – system has failed or shutdown:  
Amber  
Solid on  
Critical, non-  
recoverable  
ƒ
ƒ
ƒ
ƒ
ƒ
Thermtrip asserted.  
Non-recoverable temperature threshold asserted.  
Non-recoverable voltage threshold asserted.  
Power fault / Power Control Failure.  
Fan redundancy lost, insufficient system cooling. This does  
not apply to non-redundant systems.  
ƒ
Uncorrectable memory error.  
Non-fatal alarm – system is likely to fail:  
Amber  
Blink  
Non-critical  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
CATERR asserted.  
Critical temperature threshold asserted.  
Critical voltage threshold asserted.  
Critical fan threshold asserted.  
VRD hot asserted.  
SMI Timeout asserted.  
Correctable error threshold has been reached for a failing  
DDR3 DIMM.  
System booted and ready.  
Green  
Green  
Solid on  
Blink  
System OK  
Degraded  
System degraded:  
ƒ
ƒ
ƒ
ƒ
Non-critical temperature threshold asserted.  
Non-critical voltage threshold asserted.  
Non-critical fan threshold asserted.  
Fan redundancy lost, sufficient system cooling maintained.  
This does not apply to non-redundant systems.  
ƒ
ƒ
Power supply predictive failure.  
Unable to use all of the installed memory (more than one  
DDR3 DIMM installed).  
ƒ
Correctable error threshold has been reached for a failing  
DDR3 DIMM on a given channel.  
84  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Intel® Light Guided Diagnostics  
8.2 Post Code Diagnostic LEDs  
During the system boot process, the BIOS executes several platform configuration processes,  
each of which is assigned a specific hex POST code number. As each configuration routine is  
started, the BIOS displays the POST code on the POST code diagnostic LEDs found on the  
back edge of the server board. To assist in troubleshooting a system hang during the POST  
process, The diagnostic LEDs can be used to identify the last POST process executed.  
Table 54. POST Code Diagnostic LED Location  
A
B
C
D
E
Status LED  
F
G
H
I
Diagnostic LED #4  
ID LED  
Diagnostic LED #3  
Diagnostic LED #7 (MSB LED)  
Diagnostic LED #6  
Diagnostic LED #5  
Diagnostic LED #2  
Diagnostic LED #1  
J
Diagnostic LED #0 (LSB LED)  
Revision 1.0  
85  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design and Environmental Specifications  
IntelP®P Server Board S3420GP TPS  
9. Design and Environmental Specifications  
9.1 Intel® Server Board S3420GP Design Specifications  
The operation of the server board at conditions beyond those shown in the following table may  
cause permanent damage to the system. Exposure to absolute maximum rating conditions for  
extended periods may affect system reliability.  
Table 55. Server Board Design Specifications  
Operating Temperature  
Non-Operating Temperature  
DC Voltage  
0º C to 55º C 1 (32º F to 131º F)  
-40º C to 70º C (-40º F to 158º F)  
± 5% of all nominal voltages  
Shock (Unpackaged)  
Shock (Packaged)  
<20 pounds  
Trapezoidal, 50 G, 170 inches / sec  
36 inches  
20 to <40 pounds  
40 to <80 pounds  
80 to <100 pounds  
100 to <120 pounds  
120 pounds  
30 inches  
24 inches  
18 inches  
12 inches  
9 inches  
Vibration (Unpackaged)  
5 Hz to 500 Hz 3.13 g RMS random  
1 Chassis design must provide proper airflow to avoid exceeding the Intel® Xeon® processor maximum case  
temperature.  
Disclaimer Note: Intel Corporation server boards contain a number of high-density VLSI and  
power delivery components that need adequate airflow to cool. Intel ensures through its own  
chassis development and testing that when Intel server building blocks are used together, the  
fully integrated system will meet the intended thermal requirements of these components. It is  
the responsibility of the system integrator who chooses not to use Intel developed server  
building blocks to consult vendor datasheets and operating parameters to determine the amount  
of airflow required for their specific application and environmental conditions. Intel Corporation  
cannot be held responsible, if components fail or the server board does not operate correctly  
when used outside any of their published operating or non-operating limits.  
9.2 Board-level Calculated MTBF  
This section provides results of MTBF (Mean Time Between Failures) testing done by a third  
party testing facility. MTBF is a standard measure for the reliability and performance of the  
board under extreme working conditions. The MTBF was measured at 20000 hours at 35  
degrees Celsius.  
The following table shows the MTBF for the server boards as configured from the factory;  
Product Code  
Calculated MTBF  
335000 hours  
Operating Temperature  
35 degrees C  
35 degrees C  
Intel® Server Board S3420GPLX  
Intel® Server Board S3420GPLC  
335000 hours  
86  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Design and Environmental Specifications  
9.3 Server Board Power Requirements  
This section provides power supply design guidelines for a system using the Intel® Server Board  
S3420GP, including voltage and current specifications, and power supply on/off sequencing  
characteristics. The following diagram shows the power distribution implemented on this server  
board.  
Figure 36. Power Distribution Block Diagram  
Revision 1.0  
87  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design and Environmental Specifications  
IntelP®P Server Board S3420GP TPS  
9.3.1  
Processor Power Support  
The server board supports the Thermal Design Power (TDP) guideline for Intel® Xeon®  
processor. The Flexible Motherboard Guidelines (FMB) were also followed to help determine  
the suggested thermal and current design values for anticipating future processor needs. The  
following table provides maximum values for Icc, TDP power and T  
3400 Series processor.  
for the Intel® Xeon®  
CASE  
Table 56. Intel® Xeon® Processor TDP Guidelines  
TDP Power  
95 W  
Maximum TCASE  
67.0º C  
Icc Maximum  
150 A  
9.4 Power Supply Output Requirements  
This section is for reference purposes only. The intent is to provide guidance to system  
designers to determine a power supply for use with this server board. This section specifies the  
power supply requirements Intel used to develop a power supply for the Intel® Server System  
SR1630GP and SR1630HGP.  
The following tables define two power and current ratings for this 350-W power supply. The  
combined output power of all outputs should not exceed the rated output power. The power  
supply must meet both static and dynamic voltage regulation requirements for the minimum  
loading conditions.  
Table 57. 350-W Load Ratings  
Voltage  
+3.3 V  
Minimum Continuous  
0.2A  
Maximum Continuous  
14 A  
Peak  
+5 V  
1.0 A  
1.5A  
0A  
18A  
+12 V  
-12 V  
24 A  
0.3A  
2.0 A  
28A  
+5 VSB  
0.1 A  
2.5 A  
1. Notes:  
1. Maximum continuous total DC output power should not exceed 350 W.  
2. Peak total DC output power should not exceed 400 W.  
3. Peak power and peak current loading should be supported for a minimum of 12 seconds.  
4. Combined 3.3 V/5 V power should not exceed 100 W.  
88  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Design and Environmental Specifications  
9.4.1  
Grounding  
The grounds of the power supply output connector pins provide the power return path. The  
output connector ground pins are connected to the safety ground (power supply enclosure).  
This grounding is designed to ensure passing the maximum allowed common mode noise levels.  
The power supply is provided with a reliable protective earth ground. All secondary circuits are  
connected to protective earth ground. Resistance of the ground returns to chassis does not  
exceed 1.0 m. This path may be used to carry DC current.  
9.4.2  
Standby Outputs  
The 5 VSB output is present when an AC input greater than the power supply turn on voltage is  
applied.  
9.4.3  
Remote Sense  
The power supply has remote sense return (ReturnS) to regulate out ground drops for all output  
voltages: +3.3 V, +5 V, +12 V, -12 V, and 5 VSB. The power supply uses remote sense to  
regulate out drops in the system for the +3.3 V, +5 V, and 12 V outputs. The power supply must  
operate within specification over the full range of voltage drops from the power supply’s output  
connector to the remote sense points.  
9.4.4  
Voltage Regulation  
The power supply output voltages must stay within the following voltage limits when operating at  
steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.  
All outputs are measured with reference to the return remote sense signal (ReturnS).  
Table 58. Voltage Regulation Limits  
Parameter  
+ 3.3 V  
Tolerance  
- 5% / +5%  
Minimum  
+3.14  
Normal  
+3.30  
Maximum  
+3.46  
Units  
Vrms  
+ 5 V  
- 5% / +5%  
- 5% / +5%  
- 10% / +10%  
- 5% / +5%  
+4.75  
+11.40  
-13.20  
+4.75  
+5.00  
+12.00  
-12.00  
+5.00  
+5.25  
Vrms  
Vrms  
Vrms  
Vrms  
+ 12 V  
- 12 V  
+ 5 VSB  
+12.60  
-10.80  
+5.25  
9.4.5  
Dynamic Loading  
The output voltages remain within limits for the step loading and capacitive loading specified in  
the following table. The load transient repetition rate is tested between 50 Hz and 5 kHz at duty  
cycles ranging from 10%-90%. The load transient repetition rate is only a test specification. The  
step load may occur anywhere within the Min load to the Max load conditions.  
Table 59. Transient Load Requirements  
Output  
Load Slew Rate  
Test capacitive Load  
Step Load Size  
(See note 2)  
+3.3 V  
+5 V  
5.0 A  
0.25 A/µsec  
0.25 A/µsec  
0.25 A/µsec  
250 µF  
400 µF  
500 µF  
6.0 A  
12 V  
11.0 A  
Revision 1.0  
89  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design and Environmental Specifications  
IntelP®P Server Board S3420GP TPS  
+5 VSB  
0.5 A  
0.25 A/µsec  
20 µF  
Notes:  
1.  
Step loads on each 12 V output may happen simultaneously and should be tested that way.  
9.4.6  
Capacitive Loading  
The power supply is stable and meets all requirements with the following capacitive loading  
ranges.  
Table 60. Capacitve Loading Conditions  
Output  
+3.3 V  
Minimum  
100  
Maximum  
2200  
Units  
µF  
µF  
µF  
µF  
µF  
+5 V  
400  
500  
1
2200  
2200  
350  
+12 V  
-12 V  
+5 VSB  
20  
350  
9.4.7  
Closed-loop Stability  
The power supply is unconditionally stable under all line/load/transient load conditions including  
capacitive load ranges. A minimum of 45° phase margin and -10 dB-gain margin is required.  
The power supply manufacturer provides proof of the unit’s closed-loop stability with local  
sensing through the submission of Bode plots. Closed-loop stability is ensured at the maximum  
and minimum loads as applicable.  
9.4.8  
Common Mode Noise  
The Common Mode noise on any output does not exceed 350 mV pk-pk over the frequency  
band of 10 Hz to 20 MHz.  
ƒ
The measurement is made across a 100resistor between each of the DC outputs,  
including ground, at the DC power connector and chassis ground (power subsystem  
enclosure).  
ƒ
The test setup uses a FET probe such as Tektronix* model P6046 or equivalent.  
9.4.9  
Ripple / Noise  
The maximum allowed ripple/noise output of the power supply is defined in the following table.  
This is measured over a bandwidth of 0 Hz to 20 MHz at the power supply output connectors. A  
10 µF tantalum capacitor is placed in parallel with a 0.1 µF ceramic capacitor at the point of  
measurement.  
Table 61. Ripple and Noise  
+3.3 V  
+5 V  
+12 V  
-12 V  
+5 VSB  
50 mVp-p  
50 mVp-p  
120 mVp-p  
120 mVp-p  
50 mVp-p  
9.4.10  
Timing Requirements  
The timing requirements for the power supply operation are as follows:  
90  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Design and Environmental Specifications  
ƒ
ƒ
The output voltages must rise from 10% to within regulation limits (Tvout_rise) within 5 ms  
to 70 ms, except for 5 VSB, in which case it is allowed to rise from 1.0 ms to 25 ms.  
The +3.3 V, +5 V, and +12 V output voltages should start to rise approximately at the  
same time.  
ƒ
ƒ
All outputs must rise monotonically.  
The +5 V output must be greater than the +3.3 V output during any point of the voltage  
rise.  
ƒ
ƒ
The +5 V output must never be greater than the +3.3 V output by more than 2.25 V.  
Each output voltage should reach regulation within 50 ms (Tvout_on) of each other when  
the power supply is turned on.  
ƒ
Each output voltage should fall out of regulation within 400 msec (Tvout_off) of each other  
when the power supply is turned off.  
Figure 37 and Figure 38 shows the timing requirements for the power supply being turned on  
and off via the AC input with PSON held low and the PSON signal with the AC input applied.  
Table 62. Output Voltage Timing  
Item  
Tvout_rise  
Tvout_on  
Description  
Output voltage rise time from each main output.  
Minimum  
5.01  
Maximum  
701  
Units  
Msec  
All main outputs must be within regulation of each  
other within this time.  
50  
Msec  
Tvout_off  
All main outputs must leave regulation within this  
time.  
700  
Msec  
Note:  
1. The 5 VSB output voltage rise time should be from 1.0 ms to 25.0 ms.  
Figure 37. Output Voltage Timing  
Revision 1.0  
91  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design and Environmental Specifications  
IntelP®P Server Board S3420GP TPS  
Table 63. Turn On/Off Timing  
Item  
Tsb_on_delay  
Description  
Delay from AC being applied to 5 VSB being  
within regulation.  
Minimum  
N/A  
Maximum  
1500  
Units  
Msec  
Tac_on_delay  
Tvout_holdup  
Delay from AC being applied to all output voltages  
being within regulation.  
Msec  
Msec  
N/A  
21  
2500  
N/A  
Duration for which all output voltages stay within  
regulation after loss of AC. Measured at 80% of  
maximum load.  
Tpwok_holdup  
Tpson_on_delay  
Tpson_pwok  
Tpwok_on  
Delay from loss of AC to de-assertion of PWOK.  
Measured at 80% of maximum load.  
Msec  
Msec  
Msec  
Msec  
Msec  
20  
N/A  
400  
50  
Delay from PSON# active to output voltages within  
regulation limits.  
5
Delay from PSON# deactive to PWOK being de-  
asserted.  
N/A  
100  
Delay from output voltages within regulation limits  
to PWOK asserted at turn on.  
500  
Tpwok_off  
Delay from PWOK de-asserted to output voltages  
(3.3 V, 5 V, 12 V, -12 V) dropping out of regulation  
limits.  
1
N/A  
N/A  
Tpwok_low  
Duration of PWOK being in the de-asserted state  
during an off/on cycle using AC or the PSON  
signal.  
Msec  
100  
Tsb_vout  
Delay from 5 VSB being in regulation to O/Ps  
being in regulation at AC turn on.  
Msec  
Msec  
50  
70  
1000  
N/A  
T5VSB_holdup  
Duration for which the 5 VSB output voltage stays  
within regulation after loss of AC.  
Figure 38. Turn On/Off Timing (Power Supply Signals)  
92  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Design and Environmental Specifications  
9.4.11  
Residual Voltage Immunity in Standby Mode  
The power supply is immune to any residual voltage placed on its outputs (typically, a leakage  
voltage through the system from standby output) up to 500 mV. There is no additional heat  
generated nor stressing of any internal components with this voltage applied to any individual  
output and all outputs simultaneously. It also does not trip the power supply protection circuits  
during turn on.  
The residual voltage at the power supply outputs for a no-load condition does not exceed 100  
mV when AC voltage is applied and the PSON# signal is de-asserted.  
9.4.12  
Protection Circuits  
Protection circuits inside the power supply should cause only the power supply’s main outputs  
to shut down. If the power supply latches off due to a protection circuit tripping, an AC cycle  
OFF for 15 seconds and a PSON# cycle HIGH for 1 second should reset the power supply.  
9.4.12.1  
Over-current Protection (OCP)  
The power supply has current limits to prevent the +3.3 V, +5 V, and +12 V outputs from  
exceeding the values shown in the following table. If the current limits are exceeded, the power  
supply shuts down and latches off. The latch is cleared by toggling the PSON# signal or using  
an AC power interruption. The power supply is not damaged from repeated power cycling in this  
condition. -12 V and 5 VSB are protected under over-current or shorted conditions so no  
damage can occur to the power supply. Auto-recovery feature is a requirement on 5 VSB rail.  
Table 64. Over-Current Protection (OCP)  
VOLTAGE  
OVER CURRENT LIMIT  
Min  
Max  
21A  
+3.3V  
15A  
+5V  
20A  
27A  
40A  
2A  
+12V  
-12V  
5VSB  
30A  
0.625A  
N/A  
4A  
9.4.12.2  
Over-Voltage Protection (OVP)  
The power supply over-voltage protection is locally sensed. The power supply shuts down and  
latches off after an over-voltage condition occurs. You can clear this latch by toggling the  
PSON# signal or using an AC power interruption. The following table contains the over-voltage  
limits. The values are measured at the output of the power supply’s connectors. The voltage  
never exceeds the maximum levels when measured at the power pins of the power supply  
connector during any single point of fail. The voltage never trips any lower than the minimum  
levels when measured at the power pins of the power supply connector.  
Exception: +5 VSB rail should be able to recover after an over-voltage condition occurs.  
Table 65. Over-voltage Protection (OVP) Limits  
Output Voltage  
+3.3 V  
Minimum (V)  
3.9  
Maximum (V)  
4.5  
Revision 1.0  
93  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design and Environmental Specifications  
IntelP®P Server Board S3420GP TPS  
+5 V  
5.7  
6.2  
+12 V  
-12 V  
13.3  
-13.3  
5.7  
14.5  
-14.5  
6.5  
+5 VSB  
94  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Regulatory and Certification Information  
10. Regulatory and Certification Information  
10.1Product Regulatory Compliance  
Intended Application –This product is to be evaluated and certified as Information Technology  
Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar  
commercial type locations. The suitability of this product for other product certification  
categories and/or environments (such as: medical, industrial, telecommunications, NEBS,  
residential, alarm systems, test equipment, etc.), other than an ITE application, will require  
further evaluation and may require additional regulatory approvals.  
Note: The use and/or integration of telecommunication devices such as modems and/or  
wireless devices have not been planned for with respect to these systems. If there is any  
change of plan to use such devices, then telecommunication type certifications will require  
additional planning. If NEBS compliance is required for system level products, additional  
certification planning and design will be required.  
10.1.1 Product Safety Compliance  
ƒ
ƒ
ƒ
CSA 60950-1 Certification (Canada) or cUL  
CE Declaration to EU Low Voltage Directive 2006/95/EC (Europe – EN60950-1)  
IEC60950-1 (International) CB Certificate & Report, (report to include all CB country  
national deviations)  
ƒ
ƒ
BSMI Declaration of Conformity (Taiwan)  
UL 60950-1 Recognition (USA)  
10.1.2 Product EMC Compliance – Class A Compliance  
Note: This product requires complying with Class A EMC requirements. However, Intel targets a  
10 db margin to support customer enablement.  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
AS/NZS CISPR 22 Emissions (Australia / New Zealand)  
ICES-003 – (Canada)  
EN55022 - Emissions (Europe)  
EN55024 - Immunity (Europe)  
CE – EMC Directive 2004/108/EC (Europe)  
CISPR 22 – Emissions (International)  
KCC MIC Notice No. 1997-41 (EMC) & 1997-42  
(EMI) (Korea)  
ƒ
ƒ
BSMI CNS13438 Emissions (Taiwan)  
FCC – Part 15 Emissions (USA) Verification  
10.1.3 Certifications / Registrations / Declarations  
ƒ
UL Certification (US/Canada)  
ƒ
CE Declaration of Conformity (CENELEC Europe)  
Revision 1.0  
95  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory and Certification Information  
IntelP®P Server Board S3420GP TPS  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
FCC/ICES-003 Class A Attestation (USA/Canada)  
C-Tick Declaration of Conformity (Australia)  
MED Declaration of Conformity (New Zealand)  
BSMI Declaration (Taiwan)  
RRL Certification (Korea)  
GOST – Listed on one System License (Russia)  
Belarus – Listed on one System License (Belarus)  
Ecology Declaration (International)  
10.1.4 Product Ecology Requirements  
Intel restricts the use of banned substances in accordance with world wide product ecology  
regulatory requirements. Suppliers Declarations of Conformity to the banned substances must  
be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be  
produced to illustrate compliance. Due verification of random materials is required as a  
screening / audit to verify suppliers declarations.  
The server board complies with the following ecology regulatory requirements:  
ƒ
All materials, parts, and subassemblies must not contain restricted materials as defined  
in Intel’s Environmental Product Content Specification of Suppliers and Outsourced  
Manufacturers – http://supplier.intel.com/ehs/environmental.htm.  
ƒ
Europe - European Directive 2002/95/EC - Restriction of Hazardous Substances (RoHS)  
Threshold limits and banned substances are noted below.  
Quantity limit of 0.1% by mass (1000 PPM) for Lead, Mercury, Hexavalent Chromium,  
Polybrominated Biphenyls Diphenyl Ethers (PBB/PBDE)  
Quantity limit of 0.01% by mass (100 PPM) for Cadmium  
China RoHS  
ƒ
ƒ
All plastic parts that weigh >25gm shall be marked with the ISO11469 requirements for  
recycling. Example >PC/ABS<  
ƒ
ƒ
EU Packaging Directive  
CA. Lithium Perchlorate insert Perchlorate Material – Special handling may apply. Refer  
to http://www.dtsc.ca.gov/hazardouswaste/perchlorate.  
This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter  
33: Best Management Practices for Perchlorate Materials. This product / part includes a  
battery which contains Perchlorate material.  
ƒ
ƒ
German Green Dot  
Japan Recycling  
96  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Regulatory and Certification Information  
10.2Product Regulatory Compliance Markings  
The server board is provided with the following regulatory marks.  
Regulatory Compliance  
Region  
USA/Canada  
Marking  
UL Mark  
CE Mark  
Europe  
EMC Marking (Class A)  
BSMI Marking (Class A)  
Canada  
Taiwan  
CANADA ICES-003 CLASS A  
D33025  
C-tick Marking  
RRL MIC Mark  
Australia / New Zealand  
Korea  
N232  
: CPU-S3420GP (A)  
Country of Origin  
Exporting Requirements  
Regulatory Identification  
MADE IN xxxxx (Provided by label, not silk  
screen)  
Model Designation  
PB Free Marking?  
S3420GP  
Environmental  
Requirements  
Refer to Jedec Standard J-STD609  
China RoHS Marking  
China  
China Recycling Package  
Marking  
China  
(Marked on packaging  
label)  
Revision 1.0  
97  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory and Certification Information  
IntelP®P Server Board S3420GP TPS  
Other Recycling Package  
Marking  
Other Recycling  
Package Marks  
(Marked on packaging  
label)  
Other Recycling Package  
Marking  
CA. Lithium Perchlorate  
insert  
Perchlorate Material – Special handling may  
apply. See  
www.dtsc.ca.gov/hazardouswaste/perchlorate  
This notice is required by California Code of  
Regulations, Title 22, Division 4.5, Chapter 33:  
Best Management Practices for Perchlorate  
Materials. This product / part includes a battery  
which contains Perchlorate material.  
(Marked on packaging  
label)  
98  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Regulatory and Certification Information  
10.3 Electromagnetic Compatibility Notices  
10.3.1 FCC Verification Statement (USA)  
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1)  
This device may not cause harmful interference, and (2) this device must accept any  
interference received, including interference that may cause undesired operation.  
Intel Corporation  
5200 N.E. Elam Young Parkway  
Hillsboro, OR 97124-6497  
Phone: 1-800-628-8686  
This equipment has been tested and found to comply with the limits for a Class B digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation. This equipment generates,  
uses, and can radiate radio frequency energy and, if not installed and used in accordance with  
the instructions, may cause harmful interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If this equipment does  
cause harmful interference to radio or television reception, which can be determined by turning  
the equipment off and on, the user is encouraged to try to correct the interference by one or  
more of these measures:  
ƒ
ƒ
ƒ
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and the receiver.  
Connect the equipment into an outlet on a circuit different from that to which the  
receiver is connected.  
ƒ
Consult the dealer or an experienced radio/TV technician for help.  
Any changes or modifications not expressly approved by the grantee of this device could void  
the user’s authority to operate the equipment. The customer is responsible for ensuring  
compliance of the modified product.  
All cables used to connect to peripherals must be shielded and grounded. Operation with cables,  
connected to peripherals that are not shielded and grounded may result in interference to radio  
and TV reception.  
Revision 1.0  
99  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory and Certification Information  
IntelP®P Server Board S3420GP TPS  
10.3.2 ICES-003 (Canada)  
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux  
appareils numériques de Classe B prescrites dans la norme sur le matériel brouilleur:  
“Appareils Numériques”, NMB-003 édictée par le Ministre Canadian des Communications.  
English translation of the notice above:  
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital  
apparatus set out in the interference-causing equipment standard entitled “Digital Apparatus,”  
ICES-003 of the Canadian Department of Communications.  
10.3.3 Europe (CE Declaration of Conformity)  
This product has been tested in accordance too, and complies with the Low Voltage Directive  
(73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark  
to illustrate its compliance.  
10.3.4 VCCI (Japan)  
English translation of the notice above:  
This is a Class B product based on the standard of the Voluntary Control Council for  
Interference (VCCI) from Information Technology Equipment. If this is used near a radio or  
television receiver in a domestic environment, it may cause radio interference. Install and use  
the equipment according to the instruction manual.  
100  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Regulatory and Certification Information  
10.3.5 BSMI (Taiwan)  
The BSMI Certification Marking and EMC warning is located on the outside rear area of the  
product.  
10.3.6 RRL (Korea)  
Following is the RRL certification information for Korea.  
English translation of the notice above:  
1. Type of Equipment (Model Name): On License and Product  
2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative  
3. Name of Certification Recipient: Intel Corporation  
4. Date of Manufacturer: Refer to date code on product  
5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product  
10.3.7 CNCA (CCC-China)  
The CCC Certification Marking and EMC warning is located on the outside rear area of  
the product.  
Revision 1.0  
101  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A: Integration and Usage Tips  
IntelP®P Server Board S3420GP TPS  
Appendix A: Integration and Usage Tips  
ƒ
When adding or removing components or peripherals from the server board, AC power  
must be removed. With AC power plugged into the server board, 5-Volt standby is still  
present even though the server board is powered off.  
ƒ
ƒ
Supports only Intel® Xeon® 3400 Series processor with 95 W and less Thermal Design  
Power (TDP). Does not support previous generations of the Intel® Xeon® processor.  
On the back edge of the server board are diagnostic LEDs that display a sequence of  
amber POST codes during the boot process. If the server board hangs during POST, the  
LEDs displays the last POST event run before the hang.  
ƒ
ƒ
Supports only registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3 DIMMs  
(UDIMMs). Does not support the mixing of RDIMMs and UDIMMs.  
For the best performance, the number of DDR3 DIMMs installed should be balanced  
across both processor sockets and memory channels. For example, a two-DIMM  
configuration performs better than a one-DIMM configuration. In a two-DIMM  
configuration, DIMMs should be installed in DIMM sockets A1 and A2. A six-DIMM  
configuration (DIMM socketsA1, A2, A3, B1, B2 and B3) performs better than a three-  
DIMM configuration (DIMM sockets A1, A2, and A3).  
ƒ
ƒ
The Intel® Remote Management Module 3 (Intel® RMM3) connector is not compatible  
with the Intel® Remote Management Module (Product Order Code - AXXRMM) or Intel®  
Remote Management Module 2 (Product Order Code - AXXRMM2).  
Clear the CMOS with the AC power cord plugged in. Removing the AC power before  
performing the CMOS clear operation causes the system to automatically power up and  
immediately power down after the CMOS clear procedure is followed and AC power is  
re-applied. If this happens, remove the AC power cord, wait 30 seconds, and then re-  
connect the AC power cord. Power up the system and proceed to the <F2> BIOS Setup  
utility to reset the needed settings.  
ƒ
ƒ
Normal Integrated BMC functionality is disabled with the force Integrated BMC update  
jumper set to the “enabled” position (pins 2-3). The server should never be run with the  
Integrated BMC force update jumper set in this position and should only be used when  
the standard firmware update process fails. This jumper should remain in the default  
(disabled) position (pins 1-2) when the server is running normally.  
When performing a normal BIOS update procedure, the BIOS recovery jumper must be  
set to its default position (pins 1-2).  
102  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Appendix B: Integrated BMC Sensor Tables  
Appendix B: Integrated BMC Sensor Tables  
This appendix lists the sensor identification numbers and information about the sensor type,  
name, supported thresholds, assertion and de-assertion information, and a brief description of  
the sensor purpose. See the Intelligent Platform Management Interface Specification, Version  
2.0, for sensor and event/reading-type table information.  
ƒ
ƒ
ƒ
Sensor Type  
The Sensor Type values are the values enumerated in the Sensor Type Codes table in  
the IPMI specification. The Sensor Type provides the context in which to interpret the  
sensor, such as the physical entity or characteristic that is represented by this sensor.  
Event / Reading Type  
The Event/Reading Type values are from the Event/Reading Type Code Ranges and  
Generic Event/Reading Type Codes tables in the IPMI specification. Digital sensors are  
a specific type of discrete sensor, which have only two states.  
Event Offset/Triggers  
Event Thresholds are event-generating thresholds for threshold types of sensors.  
-
[u,l][nr,c,nc]: upper non-recoverable, upper critical, upper non-critical, lower non-  
recoverable, lower critical, lower non-critical  
-
uc, lc: upper critical, lower critical  
Event Triggers are supported event-generating offsets for discrete type sensors. The  
offsets can be found in the Generic Event/Reading Type Codes or Sensor Type Codes  
tables in the IPMI specification, depending on whether the sensor event/reading type is  
generic or a sensor-specific response.  
ƒ
ƒ
Assertion / De-assertion Enables  
Assertion and de-assertion indicators reveal the type of events the sensor generates:  
-
-
As: Assertions  
De: De-assertion  
Readable Value / Offsets  
-
Readable Value indicates the type of value returned for threshold and other non-  
discrete type sensors.  
-
Readable Offsets indicate the offsets for discrete sensors that are readable with the  
Get Sensor Reading command. Unless otherwise indicated, all event triggers are  
readable; Readable Offsets consist of the reading type offsets that do not generate  
events.  
ƒ
Event Data  
Event data is the data that is included in an event message generated by the sensor. For  
threshold-based sensors, the following abbreviations are used:  
-
-
R: Reading value  
T: Threshold value  
Revision 1.0  
103  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B: Integrated BMC Sensor Tables  
IntelP®P Server Board S3420GP TPS  
ƒ
Rearm Sensors  
The rearm is a request for the event status for a sensor to be rechecked and updated  
upon a transition between good and bad states. Rearming the sensors can be done  
manually or automatically. This column indicates the type supported by the sensor. The  
following abbreviations are used to describe a sensor:  
-
-
A: Auto-rearm  
M: Manual rearm  
ƒ
ƒ
ƒ
Default Hysteresis  
The hysteresis setting applies to all thresholds of the sensor. This column provides the  
count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).  
Criticality  
Criticality is a classification of the severity and nature of the condition. It also controls the  
behavior of the Control Panel Status LED  
Standby  
Some sensors operate on standby power. These sensors may be accessed and / or  
generate events when the main (system) power is off, but AC power is present.  
104  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Appendix B: Integrated BMC Sensor Tables  
Table 66. Integrated BMC Core Sensors  
Sensor Name3  
Sensor  
#
Platform  
Applicabilit  
y
Sensor  
Type  
Event /  
Reading  
Type  
Event Offset  
Triggers  
Contrib.  
To System  
Status  
Assert / Readabl  
Event  
Data  
Rearm Stand  
-by  
De-  
e
assert  
Value /  
Offsets  
00 - Timer  
expired, status  
only  
OK  
01 - Hard reset  
Sensor  
Specific  
Watchdog 2  
23h  
Trig Offset  
02 - Power  
down  
IPMI Watchdog  
03h  
04h  
All  
As  
A
A
X
X
6Fh  
03 - Power  
cycle  
08 - Timer  
interrupt  
00 - Chassis  
intrusion  
OK  
Degraded  
OK  
Chassis  
Intrusion is  
chassis-  
specific  
Physical  
Security  
Sensor  
Specific  
As and  
De  
Physical Scrty  
Trig Offset  
04 - LAN least  
lost  
05h  
6Fh  
00 - Front  
panel NMI /  
diagnostic  
interrupt  
Critical  
Interrupt  
Sensor  
Specific  
FP Interrupt  
(NMI)  
05h  
07h  
All  
All  
As  
As  
Trig Offset  
Trig Offset  
A
A
13h  
6Fh  
Event  
Logging  
Disabled  
Sensor  
Specific  
02 - Log area  
reset / cleared  
System Event Log  
OK  
OK  
X
6Fh  
10h  
System  
Event  
Sensor  
Specific  
04 – PEF  
action  
System Event  
08h  
10h  
All  
All  
As  
-
Trig Offset  
R, T  
A,I  
A
X
12h  
6Fh  
(System Event)  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
BB +1.05 PCH  
[u,l] [c,nc]  
Analog  
c = Non-  
fatal  
Revision 1.0  
105  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B: Integrated BMC Sensor Tables  
IntelP®P Server Board S3420GP TPS  
Sensor Name3  
Sensor  
#
Platform  
Applicabilit  
y
Sensor  
Type  
Event /  
Reading  
Type  
Event Offset  
Triggers  
Contrib.  
To System  
Status  
Assert / Readabl  
Event  
Data  
Rearm Stand  
-by  
De-  
e
assert  
Value /  
Offsets  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
BB +1.1V P1 Vccp  
BB +1.1V P2 Vccp  
11h  
12h  
All  
All  
[u,l] [c,nc]  
[u,l] [c,nc]  
Analog  
Analog  
R, T  
R, T  
A
A
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
BB +1.5V P1 DDR3  
BB +1.5V P2 DDR3  
BB +1.8V AUX  
BB +3.3V  
13h  
14h  
15h  
16h  
All  
All  
All  
All  
[u,l] [c,nc]  
[u,l] [c,nc]  
[u,l] [c,nc]  
[u,l] [c,nc]  
[u,l] [c,nc]  
Analog  
Analog  
Analog  
Analog  
R, T  
R, T  
R, T  
R, T  
A
A
A
A
X
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
BB +3.3V STBY  
BB Vbat  
17h  
18h  
All  
All  
Analog  
R, T  
A
A
X
X
c = Non-  
fatal  
01 - Limit  
exceeded  
Generic  
05h  
Voltage  
02h  
As and  
De  
Non-fatal  
Trig Offset  
106  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Appendix B: Integrated BMC Sensor Tables  
Sensor Name3  
Sensor  
#
Platform  
Applicabilit  
y
Sensor  
Type  
Event /  
Reading  
Type  
Event Offset  
Triggers  
Contrib.  
To System  
Status  
Assert / Readabl  
Event  
Data  
Rearm Stand  
-by  
De-  
e
assert  
Value /  
Offsets  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
BB +5.0V  
BB +5.0V STBY  
BB +12.0V  
19h  
1Ah  
1Bh  
1Ch  
20h  
21h  
All  
All  
All  
All  
All  
All  
[u,l] [c,nc]  
[u,l] [c,nc]  
[u,l] [c,nc]  
[u,l] [c,nc]  
[u,l] [c,nc]  
[u,l] [c,nc]  
Analog  
Analog  
Analog  
Analog  
Analog  
Analog  
R, T  
R, T  
R, T  
R, T  
R, T  
R, T  
A
A
A
A
A
A
X
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
c = Non-  
fatal  
nc =  
Degraded  
Voltage  
02h  
Threshold  
01h  
As and  
De  
BB -12.0V  
c = Non-  
fatal  
nc =  
Degraded  
Temperatur  
e
Threshold  
01h  
As and  
De  
Server board Temp  
X
X
c = Non-  
fatal  
01h  
nc =  
Degraded  
Temperatur  
e
Threshold  
01h  
As and  
De  
Front panel temp  
c = Non-  
fatal  
01h  
Temperatur  
e
Threshold  
01h  
PCH Thermal Margin  
22h  
23h  
All  
All  
-
-
-
-
-
-
Analog  
Analog  
-
-
-
-
-
-
01h  
Processor MEMTHRM  
MRGN  
Temperatur  
e
Threshold  
01h  
01h  
Revision 1.0  
107  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B: Integrated BMC Sensor Tables  
IntelP®P Server Board S3420GP TPS  
Sensor Name3  
Sensor  
#
Platform  
Applicabilit  
y
Sensor  
Type  
Event /  
Reading  
Type  
Event Offset  
Triggers  
Contrib.  
To System  
Status  
Assert / Readabl  
Event  
Data  
Rearm Stand  
-by  
De-  
e
assert  
Value /  
Offsets  
nc =  
Fan  
04h  
Threshold  
01h  
Degraded  
30h–  
34h  
Chassis-  
specific  
As and  
De  
Fan Tach Sensors  
[l] [c,nc]  
Analog  
Analog  
R, T  
M
c = Non-  
fatal2  
Temperatur  
e
Threshold  
01h  
Processor Therm  
Margin  
62h  
64h  
66h  
68h  
6Ah  
All  
All  
All  
All  
All  
01h  
Temperatur  
e
Threshold  
01h  
As and  
De  
Processor Therm Ctrl %  
Processor VRD Temp  
CATERR  
[u] [c]  
Non-fatal  
Fatal  
Analog Trig Offset  
A
01h  
Temperatur  
e
Digital  
Discrete  
01 - Limit  
exceeded  
As and  
De  
Trig Offset  
Trig Offset  
Trig Offset  
M
M
M
01h  
05h  
Digital  
Discrete  
Processor  
07h  
01 – State  
Asserted  
As and  
De  
Non-fatal  
Fatal  
03h  
Temperatur  
e
Digital  
Discrete  
01 – State  
Asserted  
As and  
De  
PCH Thermal Trip  
01h  
03h  
108  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Appendix C: POST Code Diagnostic LED Decoder  
Appendix C: POST Code Diagnostic LED Decoder  
During the system boot process, the BIOS executes a number of platform configuration  
processes, each of which is assigned a specific hex POST code number. As each configuration  
routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the  
back edge of the server board. To assist in troubleshooting a system hang during the POST  
process, you can use the diagnostic LEDs to identify the last POST process executed.  
Each POST code is represented by the eight amber diagnostic LEDs. The POST codes are  
divided into two nibbles: an upper nibble and a lower nibble. The upper nibble bits are  
represented by diagnostic LEDs #4, #5, #6, and #7. The lower nibble bits are represented by  
diagnostics LEDs #0, #1, #2, and #3. If the bit is set in the upper and lower nibbles, then the  
corresponding LED is lit. If the bit is clear, then the corresponding LED is off.  
The diagnostic LED #7 is labeled as “MSB”, and the diagnostic LED #0 is labeled as “LSB”.  
Figure 39. Diagnostic LED Placement Diagram  
In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The  
LEDs are decoded as follows:  
Table 67. POST Progress Code LED Example  
Upper Nibble LEDs  
Lower Nibble LEDs  
MSB  
LED #7  
8h  
LSB  
LED #0  
1h  
LEDs  
LED #6  
4h  
LED #5  
2h  
LED #4  
1h  
LED #3  
8h  
LED #2  
4h  
LED #1  
2h  
ON  
Status  
OFF  
0
ON  
1
OFF  
0
ON  
1
OFF  
1
ON  
0
OFF  
0
1
Results  
Ah  
Ch  
ƒ
Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are  
concatenated as ACh.  
Table 68. Diagnostic LED POST Code Decoder  
Checkpoint  
Diagnostic LED Decoder  
O = On, X=Off  
Description  
Upper Nibble  
Lower Nibble  
Revision 1.0  
109  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix C: POST Code Diagnostic LED Decoder  
IntelP®P Server Board S3420GP TPS  
MSB  
LSB  
8h 4h 2h 1h 8h 4h 2h 1h  
#7 #6 #5 #4 #3 #2 #1 #0  
LED  
Host Processor  
Early processor initialization (flat32.asm) where system BSP is selected  
0x04h  
0x10h  
0x11h  
0x12h  
0x13h  
X
X
X
X
X
X
X
X
X
X
X
X
O
O
O
O
X
X
X
X
X
O
X
X
X
X
X
X
X
O
O
X
X
O
X
O
X
X
X
X
Power-on initialization of the host processor (Boot Strap Processor)  
Host processor cache initialization (including AP)  
Starting application processor initialization  
SMM initialization  
Chipset  
0x21h  
X
X
O
X
X
X
X
O
Initializing a chipset component  
Memory  
0x22h  
X
X
X
X
O
O
X
X
X
X
X
X
O
O
X
Reading configuration data from memory (SPD on FBDIMM)  
Detecting presence of memory  
0x23h  
O
0x24h  
0x25h  
0x26h  
0x27h  
0x28h  
X
X
X
X
X
X
X
X
X
X
O
O
O
O
O
X
X
X
X
X
X
X
X
X
O
O
O
O
O
X
X
X
O
O
X
X
O
X
O
X
Programming timing parameters in the memory controller  
Configuring memory parameters in the memory controller  
Optimizing memory controller settings  
Initializing memory, such as ECC init  
Testing memory  
PCI Bus  
0x50h  
0x51h  
0x52h  
0x53h  
0x54h  
0x55h  
0x56h  
0x57h  
X
X
X
X
X
X
X
X
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
O
O
O
O
X
X
O
O
X
X
O
O
X
O
X
O
X
O
X
O
Enumerating PCI buses  
Allocating resources to PCI buses  
Hot Plug PCI controller initialization  
Reserved for PCI bus  
Reserved for PCI bus  
Reserved for PCI bus  
Reserved for PCI bus  
Reserved for PCI bus  
USB  
0x58h  
0x59h  
X
X
O
O
X
X
O
O
O
O
X
X
X
X
X
Resetting USB bus  
Reserved for USB devices  
O
ATA/ATAPI/SATA  
Resetting SATA bus and all devices  
0x5Ah  
0x5Bh  
0x5Ch  
0x5Dh  
X
X
X
X
O
O
O
O
X
X
X
X
O
O
O
O
O
O
O
O
X
X
O
O
O
X
X
X
O
X
Detecting the presence of ATA device  
Enable SMART if supported by ATA device  
Reserved for ATA  
O
O
SMBUS  
0x5Eh  
0x5Fh  
X
X
O
O
X
X
O
O
O
O
O
O
O
O
X
O
Resetting SMBUS  
Reserved for SMBUS  
Local Console  
0x70h  
X
X
X
O
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
O
X
O
X
Resetting the video controller (VGA)  
Disabling the video controller (VGA)  
Enabling the video controller (VGA)  
0x71h  
0x72h  
Remote Console  
0x78h  
0x79h  
0x7Ah  
X
X
X
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
X
X
O
X
O
X
Resetting the console controller  
Disabling the console controller  
Enabling the console controller  
Keyboard (only USB)  
0x90h  
0x91h  
0x92h  
O
O
O
X
X
X
X
X
X
O
O
O
X
X
X
X
X
X
X
X
O
X
O
X
Resetting the keyboard  
Disabling the keyboard  
Detecting the presence of the keyboard  
110  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Appendix C: POST Code Diagnostic LED Decoder  
Diagnostic LED Decoder  
O = On, X=Off  
Checkpoint  
Upper Nibble  
MSB  
Lower Nibble  
LSB  
Description  
8h 4h 2h 1h 8h 4h 2h 1h  
#7 #6 #5 #4 #3 #2 #1 #0  
LED  
0x93h  
0x94h  
0x95h  
O
O
O
X
X
X
X
X
X
O
O
O
X
X
X
X
O
O
O
X
X
O
X
O
Enabling the keyboard  
Clearing keyboard input buffer  
Reserved for keyboard  
Mouse (only USB)  
Resetting the mouse  
0x98h  
0x99h  
O
O
O
O
X
X
X
X
X
X
X
X
O
O
O
O
X
X
X
X
X
X
O
O
O
O
X
O
X
Detecting the mouse  
Detecting the presence of mouse  
Enabling the mouse  
0x9Ah  
O
O
0x9Bh  
O
Fixed Media  
0xB0h  
Resetting fixed media device  
Disabling fixed media device  
O
O
X
X
O
O
O
O
X
X
X
X
X
X
X
0xB1h  
O
Detecting presence of a fixed media device (SATA hard drive detection,  
etc.)  
Enabling / configuring a fixed media device  
0xB2h  
O
X
X
O
O
O
O
X
X
X
X
O
O
X
0xB3h  
O
O
Removable Media  
0xB8h  
0xB9h  
O
O
X
X
O
O
O
O
O
O
X
X
X
X
X
Resetting removable media device  
Disabling removable media device  
O
Detecting presence of a removable media device (SATA CDROM  
detection, etc.)  
Enabling / configuring a removable media device  
0xBAh  
O
X
O
O
O
O
O
X
O
X
X
X
0xBCh  
O
X
O
O
Boot Device Selection (BDS)  
0xD0  
0xD1  
0xD2  
0xD3  
0xD4  
0xD5  
O
O
O
O
O
O
O
O
O
O
X
X
X
X
X
O
O
O
O
O
X
X
X
X
X
X
X
X
X
O
X
X
O
O
X
X
O
X
Entered the Boot Device Selection phase (BDS)  
Return to last good boot device  
Setup boot device selection policy  
Connect boot device controller  
O
X
Attempt flash update boot mode  
Transfer control to EFI boot  
X
X
O
O
O
O
X
O
O
O
X
O
O
X
O
0xD6  
0xDF  
Trying to boot device selection  
O
O
O
O
X
X
O
O
O
Reserved for boot device selection  
Pre-EFI Initialization (PEI) Core  
0xE0h  
0xE1h  
0xE2h  
0xE3h  
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O
X
Entered Pre-EFI Initialization phase (PEI)  
Started dispatching early initialization modules (PEIM)  
Initial memory found, configured, and installed correctly  
Transfer control to the DXE Core  
O
O
O
Driver eXecution Environment (DXE) Core  
Entered EFI driver execution phase (DXE)  
Started dispatching drivers  
0xE4h  
0xE5h  
O
O
O
O
O
O
O
O
O
X
X
X
X
X
X
O
O
O
X
X
O
X
O
X
Started connecting drivers  
0xE6h  
DXE Drivers  
0xE7h  
O
O
O
O
O
O
O
O
O
X
X
X
O
O
O
O
X
X
X
X
X
O
X
Waiting for user input  
Checking password  
Entering BIOS setup  
0xE8h  
0xE9h  
O
0xEAh  
0xEEh  
0xEFh  
O
O
O
O
O
O
O
O
O
X
X
X
O
O
O
O
O
O
X
X
X
X
X
O
Flash Update  
Calling Int 19. One beep unless silent boot is enabled.  
Unrecoverable boot failure  
Revision 1.0  
111  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix C: POST Code Diagnostic LED Decoder  
IntelP®P Server Board S3420GP TPS  
Diagnostic LED Decoder  
O = On, X=Off  
Checkpoint  
LED  
Upper Nibble  
MSB  
8h 4h 2h 1h 8h 4h 2h 1h  
#7 #6 #5 #4 #3 #2 #1 #0  
Lower Nibble  
LSB  
Description  
Pre-EFI Initialization Module (PEIM) / Recovery  
Crisis recovery has been initiated because of a user request  
0x30h  
0x31h  
0x34h  
0x35h  
0x3Fh  
X
X
X
X
X
X
X
X
X
X
O
O
O
O
O
O
O
O
O
O
X
X
X
X
O
X
X
X
X
X
X
O
X
O
X
Crisis recovery has been initiated by software (corrupt flash)  
Loading crisis recovery capsule  
O
O
O
Handing off control to the crisis recovery capsule  
Crisis recovery capsule failed integrity check of capsule descriptors  
O
O
Runtime Phase / EFI Operating System Boot  
0XF2h  
0XF4h  
0XF5h  
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
X
O
X
Signal that the OS has switched to virtual memory mode  
Entering the sleep state  
O
O
X
X O  
X
Exiting the sleep state  
Operating system has requested EFI to close boot services has been  
cancelled.  
0XF8h  
O
O
O
O
O
X
X
X
Progress Code  
Resetting the keyboard  
Disabling the keyboard  
0XF9h  
0xFAh  
O
O
X
X
X
X
O
O
X
X
X
X
X
X
X
O
112  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Appendix D: POST Code Errors  
Appendix D: POST Code Errors  
Whenever possible, the BIOS outputs the current boot progress codes on the video screen.  
Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class,  
subclass, and operation information. The class and subclass fields point to the type of hardware  
that is being initialized. The operation field represents the specific initialization activity. Based on  
the data bit availability to display progress codes, a progress code can be customized to fit the  
data width. The higher the data bit, the higher the granularity of information that can be sent on  
the progress port. The progress codes may be reported by the system BIOS or option ROMs.  
The Response section in the following table is divided into three types:  
ƒ
ƒ
ƒ
No Pause: The message displays on the screen during POST or in the Error Manager.  
The system continues booting with a degraded state. The user may want to replace the  
erroneous unit. The setup POST error Pause setting does not have any effect with this  
error.  
Pause: The message displays on the Error Manager screen, and an error is logged to  
the SEL. The setup POST error Pause setting determines whether the system pauses to  
the Error Manager for this type of error, where the user can take immediate corrective  
action or choose to continue booting.  
Halt: The message displays on the Error Manager screen, an error is logged to the SEL,  
and the system cannot boot unless the error is resolved. The user must replace the  
faulty part and restart the system. The setup POST error Pause setting does not have  
any effect with this error.  
Table 69. POST Error Messages and Handling  
Error Code  
0012  
Error Message  
Response  
CMOS date / time not set  
Password check failed  
Pause  
0048  
0108  
0109  
Halt  
Keyboard component encountered a locked error.  
Keyboard component encountered a stuck key error.  
No Pause  
No Pause  
Pause  
Fixed Media The SAS RAID firmware cannot run properly. The user should attempt to  
reflash the firmware.  
0113  
0140  
0141  
0146  
0192  
0194  
0195  
0196  
0197  
0198  
019F  
5220  
5221  
5224  
8110  
PCI component encountered a PERR error.  
PCI resource conflict  
Pause  
Pause  
Pause  
Halt  
PCI out of resources error  
L3 cache size mismatch  
CPUID, processor family are different  
Front side bus mismatch  
Halt  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Processor Model mismatch  
Processor speeds mismatched  
Processor family is unsupported.  
Processor and chipset stepping configuration is unsupported.  
CMOS/NVRAM Configuration Cleared  
Passwords cleared by jumper  
Password clear Jumper is Set.  
Processor 01 internal error (IERR) on last boot  
Revision 1.0  
113  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix D: POST Code Errors  
IntelP®P Server Board S3420GP TPS  
Error Code  
Error Message  
Response  
Pause  
8111  
8120  
8121  
8130  
8131  
8140  
8141  
8160  
8161  
8170  
8171  
8180  
8181  
8190  
8198  
8300  
84F2  
84F3  
84F4  
84FF  
8500  
8520  
8521  
8522  
8523  
8524  
8525  
8526  
8527  
8528  
8529  
852A  
852B  
852C  
852D  
852E  
852F  
8540  
8541  
8542  
8543  
8544  
8545  
8546  
8547  
8548  
Processor 02 internal error (IERR) on last boot  
Processor 01 thermal trip error on last boot  
Processor 02 thermal trip error on last boot  
Processor 01 disabled  
Pause  
Pause  
Pause  
Processor 02 disabled  
Pause  
Processor 01 Failed FRB-3 Timer.  
Processor 02 Failed FRB-3 Timer.  
Processor 01 unable to apply BIOS update  
Processor 02 unable to apply BIOS update  
Processor 01 failed Self Test (BIST).  
Processor 02 failed Self Test (BIST).  
No Pause  
No Pause  
Pause  
Pause  
Pause  
Pause  
Processor 01 BIOS does not support the current stepping for processor  
Processor 02 BIOS does not support the current stepping for processor  
Watchdog timer failed on last boot  
Operating system boot watchdog timer expired on last boot  
Integrated Baseboard Management Controller failed self-test  
Integrated Baseboard Management Controller failed to respond  
Integrated Baseboard Management Controller in update mode  
Sensor data record empty  
No Pause  
No Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
No Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
System event log full  
Memory component could not be configured in the selected RAS mode.  
DIMM_A1 failed Self Test (BIST).  
DIMM_A2 failed Self Test (BIST).  
DIMM_A3 failed Self Test (BIST).  
DIMM_A4 failed Self Test (BIST).  
DIMM_B1 failed Self Test (BIST).  
DIMM_B2 failed Self Test (BIST).  
DIMM_B3 failed Self Test (BIST).  
DIMM_B4 failed Self Test (BIST).  
DIMM_C1 failed Self Test (BIST).  
DIMM_C2 failed Self Test (BIST).  
DIMM_C3 failed Self Test (BIST).  
DIMM_C4 failed Self Test (BIST).  
DIMM_D1 failed Self Test (BIST).  
DIMM_D2 failed Self Test (BIST).  
DIMM_D3 failed Self Test (BIST).  
DIMM_D4 failed Self Test (BIST).  
DIMM_A1 Disabled.  
DIMM_A2 Disabled.  
DIMM_A3 Disabled.  
DIMM_A4 Disabled.  
DIMM_B1 Disabled.  
DIMM_B2 Disabled.  
DIMM_B3 Disabled.  
DIMM_B4 Disabled.  
DIMM_C1 Disabled.  
114  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Appendix D: POST Code Errors  
Error Code  
Error Message  
Response  
Pause  
8549  
854A  
854B  
854C  
854D  
854E  
854F  
8560  
8561  
8562  
8563  
8564  
8565  
8566  
8567  
8568  
8569  
856A  
856B  
856C  
856D  
856E  
856F  
8580  
8581  
8582  
8583  
8584  
8585  
8586  
8587  
8588  
8589  
858A  
858B  
858C  
858D  
858E  
858F  
85A0  
85A1  
85A2  
85A3  
85A4  
85A5  
85A6  
DIMM_C2 Disabled.  
DIMM_C3 Disabled.  
DIMM_C4 Disabled.  
DIMM_D1 Disabled.  
DIMM_D2 Disabled.  
DIMM_D3 Disabled.  
DIMM_D4 Disabled.  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
DIMM_A1 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_A2 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_A3 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_A4 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_B1 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_B2 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_B3 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_B4 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_C1 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_C2 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_C3 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_C4 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_D1 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_D2 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_D3 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_D4 Component encountered a Serial Presence Detection (SPD) fail error.  
DIMM_A1 Correctable ECC error encountered.  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause after 10 occurrences  
Pause  
DIMM_A2 Correctable ECC error encountered.  
DIMM_A3 Correctable ECC error encountered.  
DIMM_A4 Correctable ECC error encountered.  
DIMM_B1 Correctable ECC error encountered.  
DIMM_B2 Correctable ECC error encountered.  
DIMM_B3 Correctable ECC error encountered.  
DIMM_B4 Correctable ECC error encountered.  
DIMM_C1 Correctable ECC error encountered.  
DIMM_C2 Correctable ECC error encountered.  
DIMM_C3 Correctable ECC error encountered.  
DIMM_C4 Correctable ECC error encountered.  
DIMM_D1 Correctable ECC error encountered.  
DIMM_D2 Correctable ECC error encountered.  
DIMM_D3 Correctable ECC error encountered.  
DIMM_D4 Correctable ECC error encountered.  
DIMM_A1 Uncorrectable ECC error encountered.  
DIMM_A2 Uncorrectable ECC error encountered.  
Pause  
DIMM_A3 Uncorrectable ECC error encountered.  
Pause  
DIMM_A4 Uncorrectable ECC error encountered.  
Pause  
DIMM_B1 Uncorrectable ECC error encountered.  
Pause  
DIMM_B2 Uncorrectable ECC error encountered.  
Pause  
DIMM_B3 Uncorrectable ECC error encountered.  
Pause  
Revision 1.0  
115  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix D: POST Code Errors  
IntelP®P Server Board S3420GP TPS  
Error Code  
Error Message  
Response  
Pause  
85A7  
85A8  
85A9  
85AA  
85AB  
85AC  
85AD  
85AE  
85AF  
8601  
8602  
8603  
8604  
9000  
9223  
9226  
9243  
9246  
9266  
9268  
9269  
9286  
9287  
9288  
92A3  
92A9  
92C6  
92C7  
92C8  
94C6  
94C9  
9506  
95A6  
95A7  
95A8  
9609  
9641  
9667  
9687  
96A7  
96AB  
96E7  
0xA022  
0xA027  
0xA028  
0xA421  
DIMM_B4 Uncorrectable ECC error encountered.  
DIMM_C1 Uncorrectable ECC error encountered.  
DIMM_C2 Uncorrectable ECC error encountered.  
DIMM_C3 Uncorrectable ECC error encountered.  
DIMM_C4 Uncorrectable ECC error encountered.  
DIMM_D1 Uncorrectable ECC error encountered.  
DIMM_D2 Uncorrectable ECC error encountered.  
DIMM_D3 Uncorrectable ECC error encountered.  
DIMM_D4 Uncorrectable ECC error encountered.  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Pause  
Override jumper is set to force boot from lower alternate BIOS bank of flash ROM  
WatchDog timer expired (secondary BIOS may be bad!)  
Secondary BIOS checksum fail  
No Pause  
No Pause  
No Pause  
No Pause  
Pause  
Chipset Reclaim of non critical variables complete.  
Unspecified processor component has encountered a non specific error.  
Keyboard component was not detected.  
No Pause  
No Pause  
No Pause  
No Pause  
No Pause  
No Pause  
No Pause  
No Pause  
No Pause  
No Pause  
Pause  
Keyboard component encountered a controller error.  
Mouse component was not detected.  
Mouse component encountered a controller error.  
Local Console component encountered a controller error.  
Local Console component encountered an output error.  
Local Console component encountered a resource conflict error.  
Remote Console component encountered a controller error.  
Remote Console component encountered an input error.  
Remote Console component encountered an output error.  
Serial port component was not detected  
Serial port component encountered a resource conflict error  
Serial Port controller error  
Pause  
No Pause  
No Pause  
No Pause  
No Pause  
Pause  
Serial Port component encountered an input error.  
Serial Port component encountered an output error.  
LPC component encountered a controller error.  
LPC component encountered a resource conflict error.  
ATA/ATPI component encountered a controller error.  
PCI component encountered a controller error.  
No Pause  
No Pause  
No Pause  
No Pause  
No Pause  
No Pause  
Halt  
PCI component encountered a read error.  
PCI component encountered a write error.  
Unspecified software component encountered a start error.  
PEI Core component encountered a load error.  
PEI module component encountered an illegal software state error.  
DXE core component encountered an illegal software state error.  
DXE boot services driver component encountered an illegal software state error.  
DXE boot services driver component encountered invalid configuration.  
SMM driver component encountered an illegal software state error.  
Processor component encountered a mismatch error.  
Processor component encountered a low voltage error.  
Processor component encountered a high voltage error.  
PCI component encountered a SERR error.  
Halt  
Halt  
No Pause  
Halt  
Pause  
No Pause  
No Pause  
Halt  
116  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Appendix D: POST Code Errors  
Error Code  
Error Message  
Response  
No Pause  
No Pause  
No Pause  
Halt  
0xA500  
0xA501  
0xA5A0  
0xA5A1  
0xA5A4  
0xA6A0  
ATA/ATPI ATA bus SMART not supported.  
ATA/ATPI ATA SMART is disabled.  
PCI Express* component encountered a PERR error.  
PCI Express* component encountered a SERR error.  
PCI Express* IBIST error.  
Pause  
DXE boot services driver Not enough memory available to shadow a legacy option ROM.  
No Pause  
POST Error Beep Codes  
The following table lists POST error beep codes. Prior to system video initialization, the BIOS  
uses these beep codes to inform users on error conditions. The beep code is followed by a  
user-visible code on POST Progress LEDs.  
Table 70. POST Error Beep Codes  
Beeps  
Error Message  
POST Progress Code  
Description  
3
Memory error  
Multiple  
System halted because a fatal error related to the memory  
was detected.  
Revision 1.0  
117  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix E: Supported IntelP®P Server Chassis  
IntelP®P Server Board S3420GP TPS  
Appendix E: Supported Intel® Server Chassis  
The Intel® Server Board S3420GP is supported in the following Intel server chassis:  
ƒ
ƒ
Intel® Server Chassis SR1630  
Intel® Server Chassis SC5650UP  
118  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Glossary  
Glossary  
This appendix contains important terms used in this document. For ease of use, numeric entries  
are listed first (for example, “82460GX”) followed by alpha entries (for example, “AGP 4x”).  
Acronyms are followed by non-acronyms.  
Term  
ACPI  
Definition  
Advanced Configuration and Power Interface  
Application Processor  
AP  
APIC  
ARP  
ASIC  
ASMI  
BIOS  
BIST  
BMC  
Bridge  
BSP  
Byte  
Advanced Programmable Interrupt Control  
Address Resolution Protocal  
Application Specific Integrated Circuit  
Advanced Server Management Interface  
Basic Input / Output System  
Built-In Self Test  
Baseboard Management Controller  
Circuitry connecting one computer bus to another, allowing an agent on one to access the other  
Bootstrap Processor  
8-bit quantity  
CBC  
Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they  
bridge the IPMB buses of multiple chassis.  
CEK  
Common Enabling Kit  
CHAP  
CMOS  
Challenge Handshake Authentication Protocol  
Complementary Metal-oxide-semiconductor  
In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes  
of memory, which normally resides on the server board.  
DHCP  
DPC  
EEPROM  
EHCI  
EMP  
EPS  
ESB2  
FBD  
F MB  
FRB  
FRU  
FSB  
GB  
Dynamic Host Configuration Protocal  
Direct Platform Control  
Electrically Erasable Programmable Read-Only Memory  
Enhanced Host Controller Interface  
Emergency Management Port  
External Product Specification  
Enterprise South Bridge 2  
Fully Buffered DIMM  
Flexible Mother Board  
Fault Resilient Booting  
Field Replaceable Unit  
Front Side Bus  
1024 MB  
GPA  
GPIO  
GTL  
HPA  
HSC  
Hz  
Guest Physical Address  
General Purpose I/O  
Gunning Transceiver Logic  
Host Physical Address  
Hot-swap Controller  
Hertz (1 cycle / second)  
Inter-Integrated Circuit Bus  
Intel® Architecture  
I2C  
IA  
IBF  
Input Buffer  
Revision 1.0  
119  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
IntelP®P Server Board S3420GP TPS  
Term  
ICH  
Definition  
I/O Controller Hub  
ICMB  
IERR  
IFB  
Intelligent Chassis Management Bus  
Internal Error  
I/O and Firmware Bridge  
Independent Loading Mechanism  
Integrated Memory Controller  
Interrupt  
ILM  
IMC  
INTR  
I/OAT  
IOH  
I/O Acceleration Technology  
I/O Hub  
IP  
Internet Protocol  
IPMB  
IPMI  
IR  
Intelligent Platform Management Bus  
Intelligent Platform Management Interface  
Infrared  
ITP  
In-Target Probe  
KB  
1024 bytes  
KCS  
KVM  
LAN  
LCD  
LDAP  
LED  
LPC  
LUN  
MAC  
MB  
Keyboard Controller Style  
Keyboard, Video, Mouse  
Local Area Network  
Liquid Crystal Display  
Local Directory Authentication Protocol  
Light Emitting Diode  
Low Pin Count  
Logical Unit Number  
Media Access Control  
1024 KB  
MCH  
MD2  
MD5  
ME  
Memory Controller Hub  
Message Digest 2 – Hashing Algorithm  
Message Digest 5 – Hashing Algorithm – Higher Security  
Management Engine  
MMU  
ms  
Memory Management Unit  
Milliseconds  
MTTR  
Mux  
NIC  
Memory Type Range Register  
Multiplexor  
Network Interface Controller  
Nonmaskable Interrupt  
NMI  
OBF  
OEM  
Ohm  
OVP  
PECI  
PEF  
PEP  
PIA  
Output Buffer  
Original Equipment Manufacturer  
Unit of electrical resistance  
Over-voltage Protection  
Platform Environment Control Interface  
Platform Event Filtering  
Platform Event Paging  
Platform Information Area (This feature configures the firmware for the platform hardware)  
PLD  
PMI  
Programmable Logic Device  
Platform Management Interrupt  
Power-On Self Test  
POST  
120  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IntelP®P Server Board S3420GP TPS  
Term  
Glossary  
Definition  
PSMI  
PWM  
QPI  
Power Supply Management Interface  
Pulse-Width Modulation  
QuickPath Interconnect  
RAM  
RASUM  
RISC  
RMII  
Random Access Memory  
Reliability, Availability, Serviceability, Usability, and Manageability  
Reduced Instruction Set Computing  
Reduced Media-Independent Interface  
Read Only Memory  
ROM  
RTC  
Real-Time Clock (Component of ICH peripheral chip on the server board)  
Sensor Data Record  
SDR  
SECC  
SEEPROM  
SEL  
Single Edge Connector Cartridge  
Serial Electrically Erasable Programmable Read-Only Memory  
System Event Log  
SIO  
Server Input / Output  
SMBUS  
SMI  
System Management BUS  
Server Management Interrupt (SMI is the highest priority non-maskable interrupt)  
Server Management Mode  
SMM  
SMS  
SNMP  
SPS  
Server Management Software  
Simple Network Management Protocol  
Server Platform Services  
SSE2  
SSE3  
SSE4  
TBD  
Streaming SIMD Extensions 2  
Streaming SIMD Extensions 3  
Streaming SIMD Extensions 4  
To Be Determined  
TDP  
Thermal Design Power  
TIM  
Thermal Interface Material  
UART  
UDP  
Universal Asynchronous Receiver / Transmitter  
User Datagram Protocol  
UHCI  
URS  
Universal Host Controller Interface  
Unified Retention System  
UTC  
Universal time coordinare  
VID  
Voltage Identification  
VRD  
Voltage Regulator Down  
VT  
Virtualization Technology  
Word  
WS-MAN  
ZIF  
16-bit quantity  
Web Services for Management  
Zero Insertion Force  
Revision 1.0  
121  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reference Documents  
IntelP®P Server Board S3420GP TPS  
Reference Documents  
Refer to the following documents for additional information:  
ƒ
ƒ
Intel® Server Board S3420GP BIOS External Product Specification  
Intel® Server Board S3420GP Common Core Integrated BMC External Product  
Specification  
122  
Revision 1.0  
Intel order number E65697-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Water Pump 650770 X B User Manual
Ingersoll Rand Water Pump 650866 XXX B User Manual
iSimple MP3 Player Accessories IS76PRO User Manual
JBL Speaker VS3215 9 User Manual
Johnson Hardware Door 100MD User Manual
Kenmore Clothes Dryer 134313400 User Manual
KitchenAid Dishwasher KUDI22GT User Manual
KitchenAid Dishwasher W10078153A User Manual
Kompernass Toaster KH 1209 User Manual
Konica Minolta Copier IC 204 User Manual