		 651747-X-B   
					OPERATOR’S MANUAL   
					RELEASED: 6-28-92   
					INCLUDING: OPERATION, INSTALLATION & MAINTENANCE   
					REVISED:   
					(REV. G)   
					7-16-01   
					STAINLESS STEEL FLUID HEATER   
					READ THIS MANUAL CAREFULLY BEFORE INSTALLING,   
					OPERATING OR SERVICING THIS EQUIPMENT   
					. 
					It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.   
					FLUID HEATER DATA   
					DIMENSIONAL DATA   
					Models . . . . . . . . . . . . . . . . . . . . . . . . . 651747ĆXĆB   
					Wetted Parts Material . . . . . . . . . . . . . . Stainless Steel   
					651747ĆXĆB FLUID HEATER   
					Volts AC   
					651747Ć1ĆB . . . . . . . . . . . . 120   
					651747Ć2ĆB . . . . . . . . . . . . 230 / 240   
					651747Ć3ĆB . . . . . . . . . . . . 415 / 440   
					651747Ć1ĆB . . . . . . . . . . . . 16.6   
					651747Ć2ĆB . . . . . . . . . . . . 8.3   
					651747Ć3ĆB . . . . . . . . . . . . 4.5   
					7Ć1/2"   
					(190.5 mm)   
					Amperes   
					7/8" (22.2 mm)   
					4Ć3/4"   
					(120.7 mm)   
					4Ć3/16"   
					(105.6 mm)   
					1/2 Ć 14 N.P.T.F.   
					Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000   
					Accuracy . . . . . . . . . . . . . . . . . . . . . . . . ±3Ć1/2_ F (1.9_ C)   
					Temperature Rise Above Ambient . . . . . 100_ F (38_ C)   
					Recovery Rate per Hour . . . . . . . . . . . . 15 gallons (56.8 liters)   
					Maximum Working Pressure . . . . . . . . . 5000 p.s.i. (35 MPa)   
					Maximum Temperature Range . . . . . . . 60 Ć 2 50_ F (16 Ć 12 1_ C)   
					Surface Temperature Code . . . . . . . . . . T3 (392_ F / 2 00_ C)   
					Fluid Passage Diameter . . . . . . . . . . . . 0.370" (9.4 mm)   
					Fluid Passage Length . . . . . . . . . . . . . . 91.7" (232.9 cm)   
					Mounting holes (hidden)   
					Thermometer - Do not overĆ   
					tighten. For orientation only.   
					1/2 Ć 14 N.P.T.F. (Outlet)   
					16Ć1/16"   
					(408.0 mm)   
					3 
					Fluid Passage Volume . . . . . . . . . . . . . . 9.86 in. (0.162lit.)   
					Inlet / Outlet Port Size (female) . . . . . . . 1/2Ć 14 N.P.T.F. Ć 1   
					Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 18 lbs (8.2kg)   
					3Ć3/4"   
					(95.3 mm)   
					8Ć13/16"   
					(223.8 mm)   
					GENERAL DESCRIPTION   
					The Aro stainless steel fluid heater models are wired for 120, 230 / 240   
					and 415 / 440 volt AC applications. The heating element is a 2000 watt   
					cartridge type and is thermostatically controlled. The wiring, heating   
					element and thermostat are protected by a preset heat limiter.   
					The thermostat is adjustable up to 250_ F (121_ C). The heater is off   
					when the thermostat knob is turned counterclockwise as far as posĆ   
					sible. The heater will not switch on until the knob is rotated to at least   
					ambient room temperature.   
					Fluid heaters have been tested in a water solution. Some of this fluid   
					may be left within the heater, therefore flush out this fluid with a solvent   
					compatible with the material to be pumped.   
					• This unit utilizes an explosionĆproof electrical section and internally   
					spiraling material section. The material enters the base under line   
					pressure from the pump and is heated and delivered thru to the maĆ   
					terial outlet at the top.   
					1/2 Ć 14 N.P.T.F. (Inlet)   
					R 
					FIGURE 1   
					OPERATING PRECAUTIONS   
					• Heed all warnings.   
					WARNING Do not exceed 5000 p.s.i. (35 MPa) maximum.   
					WARNING HIGH PRESSURE DEVICE. Improper usage of   
					this equipment could result in serious injury. The possibility of   
					injection into the flesh is a potential hazard. Never allow any   
					part of the human body to come in front of, or in direct contact   
					with, the material outlet. An injection injury can be serious. If   
					injection should occur, contact a qualified physician for immeĆ   
					diate treatment.   
					• This unit is CSA certified for Class I, Division 1, Group D, HazardĆ   
					ous Locations, Temperature Code (identification number) T3.   
					• Two or more paint heaters may be coupled together by plumbing   
					the material outlet of the first heater to the material inlet of the next,   
					etc. However, the distance of piping run between the units should   
					be limited to no more than three feet (see figure 4, page 4).   
					CAUTION Electrical supply power to the heater must be off   
					during flushing operation.   
					CAUTION Use only genuine Aro replacement parts to asĆ   
					sure compatible pressure rating and longest service life.   
					TYPICAL INSTALLATION   
					The heater inlet and outlet should be plumbed (up flow) as shown (see   
					figure 4, page 4), to minimize chances of trapped air inside the heater. If   
					the inlet and outlet are reversed (down flow), the temperature rise will   
					be different.   
					INGERSOLL-RAND COMPANY   
					P.O. BOX 151 D ONE ARO CENTER D BRYAN, OHIO 43506Ć0151   
					& 
					(419) 636-4242   
					D 
					FAX (419) 633-1674   
					E2001 D PRINTED IN U.S.A.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				PARTS LIST / 651747-X-B   
					A 
					B 
					QTY   
					15   
					13 9, 8 D   
					1 
					3 
					2 H   
					ITEM DESCRIPTION (Size in inches)   
					PART NO.   
					: 1 14 Gauge Wire (12" long, black)   
					(1) 78140ĆXXXĆX   
					(6) Y99Ć678   
					(1) 78141ĆXXXĆX   
					(1) Y76Ć103ĆC   
					(1) 78143   
					2 
					Cap Screw (3/8" Ć 16 x 7/8")   
					: 3 14 Gauge Wire (12" long, red)   
					4 
					Machine Screw (#10 Ć 24 x 1/4")   
					36   
					5 
					Ring Terminal   
					: 6 14 Gauge Wire (7" long, green)   
					(1) 78142ĆXXXĆX   
					(1) Y227Ć5ĆL   
					(4) Y8Ć468ĆC   
					(4) Y22Ć6ĆC   
					(2) 92932   
					7 
					8 
					9 
					Pipe Plug (1/2 Ć 14 P.T.F.)   
					Machine Screw (#6 Ć 32 x 5/8")   
					Nut (#6 Ć 32)   
					5 
					6 
					35   
					10 Terminal Block   
					11 Lockwasher (#6)   
					12 Machine Screw (#6 Ć 32 x 1/4")   
					13 Mounting Plate   
					14 Thermometer (0_ Ć 250_ F)   
					15 Site Ring   
					7 
					14   
					11, 12 10   
					(4) Y1Ć6   
					A 
					B 
					(4) Y8Ć463ĆC   
					(1) 93583Ć1   
					(1) 91696   
					17   
					18   
					20   
					19 V   
					(1) 93588Ć1   
					(1) 29664   
					16 Retaining Ring   
					17 Adjusting Knob   
					18 Screw   
					16   
					(1) 93586Ć1   
					(1) 93585Ć1   
					(1) 93584Ć1   
					(1) 93587Ć1   
					(1) 93590Ć1   
					(1) 92974   
					4 
					21   
					19 Cap   
					29   
					28   
					20 Cover   
					1Ć11/16"   
					(42.9 mm)   
					21 Housing   
					22 Fluid Track   
					23 Cutoff Assembly   
					24 Heater Cartridge Assembly (+10% / Ć5%)   
					(1) 66834Ć1   
					27   
					Mounting Holes (2)   
					5/16 Ć 18 UNC Ć2B   
					1/2" (12.7 mm) deep   
					H 26   
					22   
					651747Ć1ĆB   
					651747Ć2ĆB   
					651747Ć3ĆB   
					(120 volt AC, 6.84 Ohms)   
					(1) 66751Ć1   
					(1) 66751Ć2   
					(1) 66751Ć3   
					(1) Y17Ć53   
					(3) Y99Ć63   
					(1) 93589Ć1   
					(230 / 240 volt AC, 27.36 Ohms)   
					(415 / 440 volt AC, 91.96 Ohms)   
					``B"   
					23   
					25 Pipe Plug (1/2 Ć 14 N.P.T.)   
					26 Cap Screw (3/8" Ć 16 x 1Ć1/4")   
					27 Retaining Ring   
					(ref.) 1   
					5 
					6 
					7 
					8 
					(ref.) 3   
					(ref.) 6   
					28 Indicator Lamp models 651747Ć1ĆB (120 volt AC) (1) 93591Ć1   
					models 651747Ć2ĆB (220 volt AC) (1) 93591Ć3   
					models 651747Ć3ĆB (440 volt AC) (1) 93591Ć5   
					View B Ć B   
					` 
					29 Thermostat (60_ Ć 250_ F) (20 amp. / 480 volt AC) (1) 92972   
					32   
					31   
					30   
					30 Terminal   
					: 31 14 Gauge Wire (6" long, black)   
					32 Terminal   
					(5) 78035   
					(2) 78140ĆXXXĆX   
					(2) 78143   
					33   
					34   
					1 
					2 
					3 
					4 
					33 Terminal   
					(2) 78034Ć1   
					(2) 78031   
					s 24   
					34 Terminal   
					35 Label   
					(1) 91081   
					``C"   
					25   
					View A Ć A   
					36 Mounting Plate   
					(1) 95634   
					: Available in bulk rolls only.   
					(24) Heater Cartridge   
					FIGURE 2   
					(28) Indicator Lamp   
					``B" Outlet (1/2Ć 14 N.P.T.F. Ć 1)   
					``C" Inlet (1/2Ć 14 N.P.T.F. Ć 1)   
					(6) Green   
					8 
					(23) Cutoff Assembly   
					(29) Thermostat   
					4 
					7 
					6 
					3 
					H 
					(2 and 26) Torque to 10 Ć 12 ft lbs (13.6 Ć 16.3 Nm).   
					(8) Apply Loctite 242 to threads.   
					(19) Apply Nickel antiĆseize to threads.   
					(24) Apply Watt Lube.   
					(3) Red   
					2 
					D 
					Input Line   
					(1) Black   
					V 
					5 
					1 
					s 
					` Apply Dow Corning 340 Silicone Heat Sink Compound.   
					Wiring Schematic   
					FIGURE 3   
					651747ĆXĆB   
					PAGE 3 OF4   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				TROUBLE SHOOTING   
					Fluid heater will not produce heat.   
					• No current to the heater unit.   
					Check the main power switch.   
					Check the power supply fuse, etc.   
					• Damaged thermostat.   
					Correct the wiring.   
					• Material buildĆup inside the heater.   
					Clean the fluid heater and material lines.   
					Inadequate material flow.   
					• Material buildĆup inside the heater.   
					Replace the thermostat.   
					• The heat limiter is burned out.   
					Clean the fluid heater and material lines.   
					Replace the heat limiter.   
					• The heat element is burned out.   
					Replace the heater cartridge element.   
					TYPICAL INSTALLATION   
					TYPICALSINGLE HEATER   
					TYPICAL DUAL HEATER   
					The temperature of the material is too low.   
					• The voltage to the heater is too low.   
					Correct the wiring.   
					``C"   
					• The thermostat is damaged.   
					``C"   
					Replace the thermostat.   
					• The thermostat setting is wrong.   
					Adjust the thermostat.   
					``A"   
					``A"   
					• Material buildĆup inside the heater.   
					Clean the fluid heater and material lines.   
					• The material flow is too fast.   
					Reduce the material flow.   
					``B"   
					``B"   
					The temperature of the material is too high.   
					• The thermostat is damaged.   
					Replace the thermostat.   
					``A" = Material Outlet   
					``B" = Material Inlet   
					``C" = Power In   
					• Wrong setting on the thermostat.   
					Reset the thermostat.   
					FIGURE 4   
					The heater takes too long to heat the material.   
					• The voltage is too low.   
					ACCESSORIES   
					66258 Mounting Bracket Assembly   
					6" (152.4 mm)   
					11/16" (17.5 mm)   
					2Ć1/4"   
					(57.2mm)   
					1Ć11/16"   
					(42.9 mm)   
					3/8" dia. (9.5 mm) 6x   
					FIGURE 5   
					PN 97999Ć557   
					651747ĆXĆB   
					PAGE 4 OF4   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |